165 lines
5.0 KiB
Plaintext
165 lines
5.0 KiB
Plaintext
|
|
BAY-STACK-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
bayStackMibs
|
|
FROM SYNOPTICS-ROOT-MIB;
|
|
|
|
bayStackMib MODULE-IDENTITY
|
|
LAST-UPDATED "201310110000Z"
|
|
ORGANIZATION "Nortel Networks"
|
|
CONTACT-INFO "Nortel Networks"
|
|
DESCRIPTION
|
|
"General BayStack MIB."
|
|
|
|
REVISION "201310110000Z" -- 11 October 2013
|
|
DESCRIPTION
|
|
"Version 5: Changed the MAX-ACCESS of bayStackUnitConfigIndex to read-only."
|
|
|
|
REVISION "201210020000Z" -- 02 October 2012
|
|
DESCRIPTION
|
|
"Version 4: Added spb value for bayStackUnitConfigRearPortAdminMode and bayStackUnitConfigRearPortOperMode."
|
|
|
|
REVISION "200909280000Z" -- 28 September 2009
|
|
DESCRIPTION
|
|
"Version 3: Added bayStackConfigStackRebootOnFailure and
|
|
bayStackConfigStackRetryCount."
|
|
|
|
REVISION "200709040000Z" -- 04 September 2007
|
|
DESCRIPTION
|
|
"Version 2: Added per-unit configuration table."
|
|
|
|
REVISION "200508220000Z" -- 22 August 2005
|
|
DESCRIPTION
|
|
"Version 1: Initial version."
|
|
|
|
::= { bayStackMibs 13 }
|
|
|
|
bayStackObjects OBJECT IDENTIFIER ::= { bayStackMib 1 }
|
|
|
|
--
|
|
-- General Stack configuration group
|
|
--
|
|
|
|
bayStackConfig OBJECT IDENTIFIER ::= { bayStackObjects 1 }
|
|
|
|
bayStackConfigExpectedStackSize OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expected stack size. A unit that expects to be
|
|
standalone would use a value of 1."
|
|
::= { bayStackConfig 1 }
|
|
|
|
bayStackConfigStackErrorNotificationInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
UNITS "Seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects controls the frequency with which
|
|
bsnStackConfigurationError notifications are generated."
|
|
DEFVAL { 60 }
|
|
::= { bayStackConfig 2 }
|
|
|
|
bayStackConfigStackErrorNotificationEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects controls whether bsnStackConfigurationError
|
|
notifications are generated."
|
|
::= { bayStackConfig 3 }
|
|
|
|
bayStackConfigStackRebootUnitOnFailure OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls whether to reboot any unit in a stack whose
|
|
stack ports do not go logically up."
|
|
::= { bayStackConfig 4 }
|
|
|
|
bayStackConfigStackRetryCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4294967295)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stack retry count."
|
|
::= { bayStackConfig 5 }
|
|
|
|
--
|
|
-- General Stack Per-Unit Configuration Table
|
|
--
|
|
|
|
bayStackUnitConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BayStackUnitConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains per-unit configuration data for a stack."
|
|
::= { bayStackObjects 2 }
|
|
|
|
bayStackUnitConfigEntry OBJECT-TYPE
|
|
SYNTAX BayStackUnitConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of configuration data for a stacked unit."
|
|
INDEX { bayStackUnitConfigIndex }
|
|
::= { bayStackUnitConfigTable 1 }
|
|
|
|
BayStackUnitConfigEntry ::=
|
|
SEQUENCE {
|
|
bayStackUnitConfigIndex Integer32,
|
|
bayStackUnitConfigRearPortAdminMode INTEGER,
|
|
bayStackUnitConfigRearPortOperMode INTEGER
|
|
}
|
|
|
|
bayStackUnitConfigIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit number of an entry."
|
|
::= { bayStackUnitConfigEntry 1 }
|
|
|
|
bayStackUnitConfigRearPortAdminMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standalone(1),
|
|
stacking(2),
|
|
spb(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current administrative rear-port mode for this unit. This
|
|
value will be applied at the next stack re-boot if it is different
|
|
from the current operational value. Supported values are: standalone
|
|
(rear-port mode is enabled normal), stacking (rear-port mode is disabled)
|
|
and spb(rear-port mode is enabled with loopback port reserved)."
|
|
::= { bayStackUnitConfigEntry 2 }
|
|
|
|
bayStackUnitConfigRearPortOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standalone(1),
|
|
stacking(2),
|
|
spb(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational rear-port mode for this unit. Supported values are:
|
|
standalone (operational rear-port mode is enabled normal), stacking (operational
|
|
rear-port mode is disabled) and spb(operational rear-port mode is enabled
|
|
with loopback port reserved)."
|
|
::= { bayStackUnitConfigEntry 3 }
|
|
|
|
END
|
|
|