Observium_CE/mibs/media5/MX-EAM-MIB

1691 lines
55 KiB
Plaintext

-- ****************************************************************************
-- ****************************************************************************
-- Copyright(c) 2004 Mediatrix Telecom, Inc.
-- NOTICE:
-- This document contains information that is confidential and proprietary
-- to Mediatrix Telecom, Inc.
-- Mediatrix Telecom, Inc. reserves all rights to this document as well as
-- to the Intellectual Property of the document and the technology and
-- know-how that it includes and represents.
-- This publication cannot be reproduced, neither in whole nor in part in
-- any form whatsoever without written prior approval by
-- Mediatrix Telecom, Inc.
-- Mediatrix Telecom, Inc. reserves the right to revise this publication
-- and make changes at any time and without the obligation to notify any
-- person and/or entity of such revisions and/or changes.
-- ****************************************************************************
-- ****************************************************************************
MX-EAM-MIB
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Unsigned32,
Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
MxEnableState,
MxActivationState,
MxIpHostName,
MxIpAddress,
MxIpPort,
MxAdvancedIpPort,
MxIpSubnetMask,
MxDigitMap
FROM MX-TC
MxUInt64,
MxFloat32,
MxIpHostNamePort,
MxIpAddr,
MxIpAddrPort,
MxIpAddrMask,
MxUri,
MxUrl
FROM MX-TC2
mediatrixServices
FROM MX-SMI2;
eamMIB MODULE-IDENTITY
LAST-UPDATED "1910210000Z"
ORGANIZATION " Mediatrix Telecom, Inc. "
CONTACT-INFO " Mediatrix Telecom, Inc.
4229, Garlock Street
Sherbrooke (Quebec)
Canada
Phone: (819) 829-8749
"
DESCRIPTION " E&M Channel Associated Signaling
The E&M Channel Associated Signaling (EAM) service manages the
E&M CAS telephony interfaces.
"
::= { mediatrixServices 1880 }
eamMIBObjects OBJECT IDENTIFIER ::= { eamMIB 1 }
-- ****************************************************************************
-- Group:E&M Configuration
-- ****************************************************************************
eamGroup OBJECT IDENTIFIER
::= { eamMIBObjects 100 }
-- ***************************************************************************
-- Table:E&M Channel Associated Signaling
-- ***************************************************************************
eamTable OBJECT-TYPE
SYNTAX SEQUENCE OF EamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " E&M Channel Associated Signaling
Configuration parameters related to the E&M channel associated
signaling on this managed device.
"
::= { eamGroup 100 }
eamEntry OBJECT-TYPE
SYNTAX EamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table E&M Channel Associated Signaling. "
INDEX {
eamName
}
::= { eamTable 1 }
EamEntry ::= SEQUENCE
{
eamName OCTET STRING,
eamChannelRange OCTET STRING,
eamChannelAllocationStrategy INTEGER,
eamMaxActiveCalls Unsigned32,
eamEncodingScheme INTEGER,
eamSignalingType INTEGER,
eamDigitAttenuation Unsigned32
}
-- Index:Name
eamName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Name
Name that identifies the interface.
"
::= { eamEntry 100 }
-- Columnar:Channel Range
eamChannelRange OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE(1..10) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Channel Range
Defines the range of active bearer channels.
"
DEFVAL { "1-24" }
::= { eamEntry 200 }
-- Columnar:Channel Allocation Strategy
eamChannelAllocationStrategy OBJECT-TYPE
SYNTAX INTEGER { ascending(100) , descending(200) ,
roundRobinAscending(300) , roundRobinDescending(400) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Channel Allocation Strategy
Defines the strategy for selecting bearer channels. Available
strategies are:
* Ascending: select the lowest-numbered non-busy bearer
channel
* Descending: select the highest-numbered non-busy bearer
channel
* RoundRobinAscending: use a cyclic round-robin search;
starting from the bearer channel that follows the bearer
channel used for the last call, select the
lowest-numbered non-busy bearer channel
* RoundRobinDescending: use a cyclic round-robin search;
starting from the bearer channel that precedes the bearer
channel used for the last call, select the
highest-numbered non-busy bearer channel
"
DEFVAL { ascending }
::= { eamEntry 300 }
-- Columnar:Maximum Active Calls
eamMaxActiveCalls OBJECT-TYPE
SYNTAX Unsigned32 ( 0..30 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Maximum Active Calls
Defines the maximum number of active calls on the interface.
Note: The special value 0 indicates no maximum number of
active calls.
"
DEFVAL { 0 }
::= { eamEntry 400 }
-- Columnar:Encoding Scheme
eamEncodingScheme OBJECT-TYPE
SYNTAX INTEGER { g711alaw(100) , g711ulaw(200) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Encoding Scheme
Defines the voice encoding scheme in the bearer capabilities.
"
DEFVAL { g711alaw }
::= { eamEntry 500 }
-- Columnar:Signaling Type
eamSignalingType OBJECT-TYPE
SYNTAX INTEGER { winkStart(100) , immediateStart(200) , fgb(300) ,
fgd(400) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Signaling Type
Identifies the E&M signaling type.
* E&M Wink start: Set configuration parameters for basic
Wink Start signaling. After setting SignalingType,
individual configuration parameters can be overriden for
detail adjustment.
* E&M Immediate Start: Set configuration parameters for
basic Immediate Start signaling. After setting
SignalingType, individual configuration parameters can be
overriden for detail adjustment.
* E&M Feature Group B: Set configuration parameters for the
Feature Group B signaling defined by National Exchange
Carrier Association. After setting SignalingType,
individual configuration parameters can be overriden for
detail adjustment.
* E&M Feature Group D: Set configuration parameters for the
Feature Group D signaling defined by National Exchange
Carrier Association. After setting SignalingType,
individual configuration parameters can be overriden for
detail adjustment.
"
DEFVAL { winkStart }
::= { eamEntry 600 }
-- Columnar:Digit Attenuation
eamDigitAttenuation OBJECT-TYPE
SYNTAX Unsigned32 ( 0..20 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Digit Attenuation
Additional attenuation in dB for MFR1/DTMF digits generation.
By default, MFR1/DTMF digits generation power is determined
by variant selection. This parameter provides a mean to
reduce this power.
"
DEFVAL { 0 }
::= { eamEntry 700 }
-- End of table:E&M Channel Associated Signaling
-- ***************************************************************************
-- Table:E&M Signaling Variants
-- ***************************************************************************
eamSignalingVariantsTable OBJECT-TYPE
SYNTAX SEQUENCE OF EamSignalingVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " E&M Signaling Variants
This table allows to override or retrieve the default
signaling settings for E&M signaling parameters. This table is
effective only if the OverrideDefault parameter is Enabled. If
the OverrideDefault parameter is Disabled, any change in this
table has no effects.
"
::= { eamGroup 200 }
eamSignalingVariantsEntry OBJECT-TYPE
SYNTAX EamSignalingVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table E&M Signaling Variants. "
INDEX {
eamSignalingVariantsInterfaceName
}
::= { eamSignalingVariantsTable 1 }
EamSignalingVariantsEntry ::= SEQUENCE
{
eamSignalingVariantsInterfaceName OCTET STRING,
eamSignalingVariantsOverrideDefault MxEnableState,
eamSignalingVariantsBitsBCD Integer32,
eamSignalingVariantsDnisLength Unsigned32,
eamSignalingVariantsAniLength Unsigned32,
eamSignalingVariantsIncomingRegisterSignaling INTEGER,
eamSignalingVariantsOutgoingRegisterSignaling INTEGER,
eamSignalingVariantsIncomingDialMap OCTET STRING,
eamSignalingVariantsOutgoingDialMap OCTET STRING,
eamSignalingVariantsWaitWink MxEnableState,
eamSignalingVariantsWaitWinkAck MxEnableState,
eamSignalingVariantsSendWink MxEnableState,
eamSignalingVariantsSendWinkAck MxEnableState,
eamSignalingVariantsResetSpecific INTEGER
}
-- Index:Interface Name
eamSignalingVariantsInterfaceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Interface Name
Identifies the interface.
"
::= { eamSignalingVariantsEntry 100 }
-- Columnar:Wait Wink
eamSignalingVariantsWaitWink OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Wait Wink
Defines whether or not the outgoing register should wait for
a wink before proceeding with digit transmission.
"
DEFVAL { enable }
::= { eamSignalingVariantsEntry 1000 }
-- Columnar:Wait Wink Ack
eamSignalingVariantsWaitWinkAck OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Wait Wink Ack
Defines whether or not the outgoing register should wait for
a wink acknowledge after all digit reception.
"
DEFVAL { disable }
::= { eamSignalingVariantsEntry 1100 }
-- Columnar:Send Wink
eamSignalingVariantsSendWink OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Send Wink
Defines whether or not the incoming register should send a
wink to notify the remote side that digit information can be
sent.
"
DEFVAL { enable }
::= { eamSignalingVariantsEntry 1200 }
-- Columnar:Send Wink Ack
eamSignalingVariantsSendWinkAck OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Send Wink Ack
Defines whether or not the incoming register should send a
wink to acknowledge the receipt of all digits.
"
DEFVAL { disable }
::= { eamSignalingVariantsEntry 1300 }
-- Columnar:Override Default
eamSignalingVariantsOverrideDefault OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Override Default
Overrides the default settings of E&M Signaling parameters
for the SignalingType and InterfaceName.
* Disable: The interface uses the default configuration
associated with the selected Signaling Type. The
configuration set in the current row has no effect on the
default configuration of the selected Signaling Type.
Refer to the technical documentation to get the default
configurations of the various Signaling Types.
* Enable: The interface uses the specific signaling
configuration as defined in the current row. To retrieve
the default configuration associated with the current
Signaling Type, the command implemented by the
ResetSpecific parameter MUST be issued.
"
DEFVAL { disable }
::= { eamSignalingVariantsEntry 200 }
-- Row command:Reset Specific
eamSignalingVariantsResetSpecific OBJECT-TYPE
SYNTAX INTEGER { noOp(0), resetSpecific(10) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Reset Specific
Resets specific settings of E&M Signaling parameters with the
default signaling settings. This command is used to retrieve
the default configuration of the selected Signaling Type set
in the SignalingType parameter.
"
DEFVAL { noOp }
::= { eamSignalingVariantsEntry 2000 }
-- Columnar:BCD Bits
eamSignalingVariantsBitsBCD OBJECT-TYPE
SYNTAX Integer32 ( 0..8 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " BCD Bits
Settings of the B, C and D bits when the device transmits
line signals. B, C and D bits of received line signals are
ignored by the device.
BCD bits definition
* 0..7: BCD bits are set to the specified value.
* 8: BCD bits follow the A bit.
Note: On E1-CAS, the ABCD bits pair cannot be set to '0000'.
If the BCD bits pair is set to '000' or to follow the A bit,
then the BCD bits pair is set to '001' instead.
"
DEFVAL { 8 }
::= { eamSignalingVariantsEntry 300 }
-- Columnar:DNIS Length
eamSignalingVariantsDnisLength OBJECT-TYPE
SYNTAX Unsigned32 ( 0..20 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " DNIS Length
Defines the expected length of the DNIS. DNIS (Dialed Number
Identification Service) is the called party or the
destination number.
* 0: Variable DNIS length used.
* 1..20: Number indicates the specific DNIS length
expected.
"
DEFVAL { 0 }
::= { eamSignalingVariantsEntry 400 }
-- Columnar:ANI Length
eamSignalingVariantsAniLength OBJECT-TYPE
SYNTAX Unsigned32 ( 0..20 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " ANI Length
Defines the expected length of the ANI. ANI (Automatic Number
Identification) is the number of the calling party.
* 0 : Variable ANI length.
* 1..20 : Specific ANI length.
"
DEFVAL { 0 }
::= { eamSignalingVariantsEntry 500 }
-- Columnar:Incoming Register Signaling
eamSignalingVariantsIncomingRegisterSignaling OBJECT-TYPE
SYNTAX INTEGER { mfR1(100) , dtmf(200) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Incoming Register Signaling
Defines the incoming register signaling method.
* MfR1: Multi Frequency - R1.
* Dtmf: Dual Tone Multi Frequency.
"
DEFVAL { dtmf }
::= { eamSignalingVariantsEntry 600 }
-- Columnar:Outgoing Register Signaling
eamSignalingVariantsOutgoingRegisterSignaling OBJECT-TYPE
SYNTAX INTEGER { mfR1(100) , dtmf(200) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Outgoing Register Signaling
Defines the outgoing register signaling method.
* MfR1: Multi Frequency - R1.
* Dtmf: Dual Tone Multi Frequency.
"
DEFVAL { dtmf }
::= { eamSignalingVariantsEntry 700 }
-- Columnar:Incoming Dial Map
eamSignalingVariantsIncomingDialMap OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE(0..255) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Incoming Dial Map
Defines the dial map expression to match against on the
incoming side. The dial map expression uses a special format
using macros that enables the user to construct a custom dial
map using the ANI, DNIS and other special tones as separator.
Dial map macros:
* %dnis : DNIS (Dialed Number Identification Service).
* %ani : ANI (Automatic Number Identification).
* %kp : KP (start-of-pulsing) tone (MF R1 only).
* %st : ST (end-of-pulsing) tone (MF R1 only).
* %t : Interdigit timeout.
* A,B,C,D,*,# : Control tones (DTMF only).
* A,B,C,D,E : Control tones (MF R1 only).
Examples:
* %dnis*%ani : (dnis)*(ani)
* %kp%dnis%st%kp%ani%st : KP(dnis)STKP(ani)ST
* A%dnisBA%aniB : A(dnis)BA(ani)B
"
DEFVAL { "%dnis%t" }
::= { eamSignalingVariantsEntry 800 }
-- Columnar:Outgoing Dial Map
eamSignalingVariantsOutgoingDialMap OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE(0..255) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Outgoing Dial Map
Defines the dial map format for the outgoing dial string. The
dial string generation uses a special format using macros
that enables the user to construct a custom dial string using
the ANI, DNIS and other specials tones used as separator. The
dial string uses regular expression to replace the macros
with the proper call parameter value.
Dial map macros:
* %dnis : DNIS (Dialed Number Identification Service).
* %ani : ANI (Automatic Number Identification).
* %kp : KP (start-of-pulsing) tone (MF R1 only).
* %st : ST (end-of-pulsing) tone (MF R1 only).
* %t : Interdigit timeout.
* A,B,C,D,*,# : Control tones (DTMF only).
* A,B,C,D,E : Control tones (MF R1 only).
Examples : ANI=1234 DNIS=6789 KP=A ST=D
* %dnis*%ani : 6789*1234
* %kp%dnis%st%kp%ani%st : A6789DA1234D
* A%dnisBA%aniB : A6789BA1234B
"
DEFVAL { "%dnis%t" }
::= { eamSignalingVariantsEntry 900 }
-- End of table:E&M Signaling Variants
-- ***************************************************************************
-- Table:E&M Signaling Timer Variants
-- ***************************************************************************
eamTimerVariantsTable OBJECT-TYPE
SYNTAX SEQUENCE OF EamTimerVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " E&M Signaling Timer Variants
This table allows to override or retrieve the default
signaling setting for E&M Timers.
"
::= { eamGroup 300 }
eamTimerVariantsEntry OBJECT-TYPE
SYNTAX EamTimerVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table E&M Signaling Timer Variants. "
INDEX {
eamTimerVariantsInterfaceName
}
::= { eamTimerVariantsTable 1 }
EamTimerVariantsEntry ::= SEQUENCE
{
eamTimerVariantsInterfaceName OCTET STRING,
eamTimerVariantsOverrideDefault MxEnableState,
eamTimerVariantsBwdWaitPreWinkTimeout Integer32,
eamTimerVariantsBwdSendWinkTimeout Integer32,
eamTimerVariantsBwdWait1stDigitTimeout Integer32,
eamTimerVariantsBwdClearBackwardTimeout Integer32,
eamTimerVariantsBwdDigitCompleteTimeout Integer32,
eamTimerVariantsFwdWaitWinkTimeout Integer32,
eamTimerVariantsFwdWaitMaxWinkOnTimeout Integer32,
eamTimerVariantsFwdWaitPreDialTimeout Integer32,
eamTimerVariantsFwdWaitAnswerTimeout Integer32,
eamTimerVariantsFwdClearForwardTimeout Integer32,
eamTimerVariantsReleaseGuardTimeout Integer32,
eamTimerVariantsResetSpecific INTEGER
}
-- Index:Interface Name
eamTimerVariantsInterfaceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Interface Name
Identifies the interface.
"
::= { eamTimerVariantsEntry 100 }
-- Columnar:Wait PreDial Timeout
eamTimerVariantsFwdWaitPreDialTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..5000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Wait PreDial Timeout
The amount of time an outgoing register waits after the wink
to start dialing.
This value is expressed in milliseconds (ms).
"
DEFVAL { 140 }
::= { eamTimerVariantsEntry 1000 }
-- Columnar:Wait Answer Timeout
eamTimerVariantsFwdWaitAnswerTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..300000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Wait Answer Timeout
The maximum time an outgoing register waits for the call to
be answered.
This value is expressed in milliseconds (ms).
"
DEFVAL { 180000 }
::= { eamTimerVariantsEntry 1100 }
-- Columnar:Clear Forward Timeout
eamTimerVariantsFwdClearForwardTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..30000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Clear Forward Timeout
The maximum time an outgoing register waits after sending a
clear forward line signal before transiting to the idle
state.
This value is expressed in milliseconds (ms).
"
DEFVAL { 2000 }
::= { eamTimerVariantsEntry 1200 }
-- Columnar:Release Guard Timeout
eamTimerVariantsReleaseGuardTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..10000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Release Guard Timeout
Maximum time a register waits after sending an idle line
signal to prevent a new seizure of the line.
This value is expressed in milliseconds (ms).
"
DEFVAL { 200 }
::= { eamTimerVariantsEntry 1300 }
-- Row command:Reset Specific
eamTimerVariantsResetSpecific OBJECT-TYPE
SYNTAX INTEGER { noOp(0), resetSpecific(10) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Reset Specific
Resets specific settings of E&M Timers parameters with the
default signaling type settings. This command is used to
retrieve the default configuration of the selected Signaling
Type set in the SignalingType parameter.
"
DEFVAL { noOp }
::= { eamTimerVariantsEntry 1900 }
-- Columnar:Override Default
eamTimerVariantsOverrideDefault OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Override Default
Overrides the default settings of E&M Signaling parameters
for the SignalingType and InterfaceName.
* Disable: The interface uses the default configuration
associated with the selected Signaling Type. The
configuration set in the current row has no effect on the
default configuration of the selected Signaling Type.
Refer to the technical documentation to get the default
configurations of the various Signaling Types.
* Enable: The interface uses the specific signaling
configuration as defined in the current row. To retrieve
the default configuration associated with the current
Signaling Type, the command implemented by the
ResetSpecific parameter MUST be issued.
"
DEFVAL { disable }
::= { eamTimerVariantsEntry 200 }
-- Columnar:Seizure Ack Timeout
eamTimerVariantsBwdWaitPreWinkTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..2000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Seizure Ack Timeout
Amount of time an incoming register waits before sending the
wink that acknowledges the seizure.
This value is expressed in milliseconds (ms).
"
DEFVAL { 50 }
::= { eamTimerVariantsEntry 300 }
-- Columnar:Send Wink Timeout
eamTimerVariantsBwdSendWinkTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..5000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Send Wink Timeout
Duration of the wink signal applied by the incoming register
to signal seizure acknowledgment.
This value is expressed in milliseconds (ms).
"
DEFVAL { 200 }
::= { eamTimerVariantsEntry 400 }
-- Columnar:Wait 1st Digit Timeout
eamTimerVariantsBwdWait1stDigitTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..20000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Wait 1st Digit Timeout
Maximum time an incoming register waits for the first
incoming digit after the line seizure.
This value is expressed in milliseconds (ms).
"
DEFVAL { 10000 }
::= { eamTimerVariantsEntry 500 }
-- Columnar:Clear Backward Timeout
eamTimerVariantsBwdClearBackwardTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..30000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Clear Backward Timeout
The maximum time an incoming register waits after sending a
clear backward line signal before transiting to the idle
state.
This value is expressed in milliseconds (ms).
"
DEFVAL { 2000 }
::= { eamTimerVariantsEntry 600 }
-- Columnar:Digit Complete Timeout
eamTimerVariantsBwdDigitCompleteTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..15000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Digit Complete Timeout
The maximum time the incoming register waits for the next
digit before considering the digit sequence as completed.
This value is expressed in milliseconds (ms).
"
DEFVAL { 4000 }
::= { eamTimerVariantsEntry 700 }
-- Columnar:Wait Wink Timeout
eamTimerVariantsFwdWaitWinkTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..10000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Wait Wink Timeout
Maximum time an outgoing register waits for seizure
acknowledgement after seizing the line.
This value is expressed in milliseconds (ms).
"
DEFVAL { 5000 }
::= { eamTimerVariantsEntry 800 }
-- Columnar:Wait Max Wink On Timeout
eamTimerVariantsFwdWaitMaxWinkOnTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..10000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Wait Max Wink On Timeout
The maximum time an outgoing register waits for the seizure
acknowledgment wink to complete.
This value is expressed in milliseconds (ms).
"
DEFVAL { 5000 }
::= { eamTimerVariantsEntry 900 }
-- End of table:E&M Signaling Timer Variants
-- ***************************************************************************
-- Table:E&M Digit Timer Variants
-- ***************************************************************************
eamDigitTimerVariantsTable OBJECT-TYPE
SYNTAX SEQUENCE OF EamDigitTimerVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " E&M Digit Timer Variants
This table allows to override or retrieve the default
signaling type setting for E&M Digit Timers.
"
::= { eamGroup 400 }
eamDigitTimerVariantsEntry OBJECT-TYPE
SYNTAX EamDigitTimerVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table E&M Digit Timer Variants. "
INDEX {
eamDigitTimerVariantsInterfaceName
}
::= { eamDigitTimerVariantsTable 1 }
EamDigitTimerVariantsEntry ::= SEQUENCE
{
eamDigitTimerVariantsInterfaceName OCTET STRING,
eamDigitTimerVariantsOverrideDefault MxEnableState,
eamDigitTimerVariantsKPOnTimeout Integer32,
eamDigitTimerVariantsKPOffTimeout Integer32,
eamDigitTimerVariantsResetSpecific INTEGER
}
-- Index:Interface Name
eamDigitTimerVariantsInterfaceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Interface Name
Identifies the interface.
"
::= { eamDigitTimerVariantsEntry 100 }
-- Columnar:Override Default
eamDigitTimerVariantsOverrideDefault OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Override Default
Overrides the default settings of E&M Signaling parameters
for the SignalingType and InterfaceName.
* Disable: The interface uses the default configuration
associated with the selected Signaling Type. The
configuration set in the current row has no effect on the
default configuration of the selected Signaling Type.
Refer to the technical documentation to get the default
configurations of the various Signaling Types.
* Enable: The interface uses the specific signaling
configuration as defined in the current row. To retrieve
the default configuration associated with the current
Signaling Type, the command implemented by the
ResetSpecific parameter MUST be issued.
"
DEFVAL { disable }
::= { eamDigitTimerVariantsEntry 200 }
-- Columnar:Duration of the MF R1 KP signal
eamDigitTimerVariantsKPOnTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..10000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Duration of the MF R1 KP signal
The time during which the MF R1 KP tone is on.
This value is expressed in milliseconds (ms).
"
DEFVAL { 100 }
::= { eamDigitTimerVariantsEntry 300 }
-- Columnar:Duration of the off portion of the MF R1 KP signal
eamDigitTimerVariantsKPOffTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..10000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Duration of the off portion of the MF R1 KP signal
The duration of the pause after the MF R1 KP tone.
This value is expressed in milliseconds (ms).
"
DEFVAL { 68 }
::= { eamDigitTimerVariantsEntry 400 }
-- Row command:Reset Specific
eamDigitTimerVariantsResetSpecific OBJECT-TYPE
SYNTAX INTEGER { noOp(0), resetSpecific(10) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Reset Specific
Resets specific settings of E&M Digit Timers parameters with
the default signaling type settings. This command is used to
retrieve the default configuration of the selected Signaling
Type set in the SignalingType parameter.
"
DEFVAL { noOp }
::= { eamDigitTimerVariantsEntry 900 }
-- End of table:E&M Digit Timer Variants
-- ***************************************************************************
-- Table:E&M Link Timer Variants
-- ***************************************************************************
eamLinkTimerVariantsTable OBJECT-TYPE
SYNTAX SEQUENCE OF EamLinkTimerVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " E&M Link Timer Variants
This table allows to override or retrieve the default
signaling type setting for E&M Link Timers.
"
::= { eamGroup 500 }
eamLinkTimerVariantsEntry OBJECT-TYPE
SYNTAX EamLinkTimerVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table E&M Link Timer Variants. "
INDEX {
eamLinkTimerVariantsInterfaceName
}
::= { eamLinkTimerVariantsTable 1 }
EamLinkTimerVariantsEntry ::= SEQUENCE
{
eamLinkTimerVariantsInterfaceName OCTET STRING,
eamLinkTimerVariantsOverrideDefault MxEnableState,
eamLinkTimerVariantsLinkActivationTimeout Integer32,
eamLinkTimerVariantsLinkActivationRetryTimeout Integer32,
eamLinkTimerVariantsResetSpecific INTEGER
}
-- Index:Interface Name
eamLinkTimerVariantsInterfaceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Interface Name
Identifies the interface.
"
::= { eamLinkTimerVariantsEntry 100 }
-- Columnar:Override Default
eamLinkTimerVariantsOverrideDefault OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Override Default
Overrides the default settings of E&M Signaling parameters
for the SignalingType and InterfaceName.
* Disable: The interface uses the default configuration
associated with the selected Signaling Type. The
configuration set in the current row has no effect on the
default configuration of the selected Signaling Type.
Refer to the technical documentation to get the default
configurations of the various Signaling Types.
* Enable: The interface uses the specific signaling
configuration as defined in the current row. To retrieve
the default configuration associated with the current
Signaling Type, the command implemented by the
ResetSpecific parameter MUST be issued.
"
DEFVAL { disable }
::= { eamLinkTimerVariantsEntry 200 }
-- Columnar:Link Activation Timeout
eamLinkTimerVariantsLinkActivationTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..10000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Link Activation Timeout
The maximum time the unit waits for an activation indication
coming from the physical link. The activation indication is
used to indicate that the physical layer connection has been
activated.
This value is expressed in milliseconds (ms).
"
DEFVAL { 1000 }
::= { eamLinkTimerVariantsEntry 300 }
-- Columnar:Link Activation Retry Timeout
eamLinkTimerVariantsLinkActivationRetryTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0..10000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Link Activation Retry Timeout
The maximum time the unit waits before attempting to
reestablish the physical link. The attempt is made when the
physical layer connection has been deactivated.
This value is expressed in milliseconds (ms).
"
DEFVAL { 3000 }
::= { eamLinkTimerVariantsEntry 400 }
-- Row command:Reset Specific
eamLinkTimerVariantsResetSpecific OBJECT-TYPE
SYNTAX INTEGER { noOp(0), resetSpecific(10) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Reset Specific
Resets specific settings of E&M Link Timers parameters with
the default signaling settings. This command is used to
retrieve the default signaling configuration set in the
SignalingType parameter.
"
DEFVAL { noOp }
::= { eamLinkTimerVariantsEntry 900 }
-- End of table:E&M Link Timer Variants
-- ***************************************************************************
-- Table:E&M Signaling Tone Variants
-- ***************************************************************************
eamToneVariantsTable OBJECT-TYPE
SYNTAX SEQUENCE OF EamToneVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " E&M Signaling Tone Variants
This table allows to override or retrieve the default
signaling setting for E&M Tone variants.
"
::= { eamGroup 600 }
eamToneVariantsEntry OBJECT-TYPE
SYNTAX EamToneVariantsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table E&M Signaling Tone Variants. "
INDEX {
eamToneVariantsInterfaceName
}
::= { eamToneVariantsTable 1 }
EamToneVariantsEntry ::= SEQUENCE
{
eamToneVariantsInterfaceName OCTET STRING,
eamToneVariantsOverrideDefault MxEnableState,
eamToneVariantsKpTone INTEGER,
eamToneVariantsStTone INTEGER,
eamToneVariantsResetSpecific INTEGER
}
-- Index:Interface Name
eamToneVariantsInterfaceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Interface Name
Identifies the interface.
"
::= { eamToneVariantsEntry 100 }
-- Columnar:Override Default
eamToneVariantsOverrideDefault OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Override Default
Overrides the default settings of E&M Signaling parameters
for the SignalingType and InterfaceName.
* Disable: The interface uses the default configuration
associated with the selected Signaling Type. The
configuration set in the current row has no effect on the
default configuration of the selected Signaling Type.
Refer to the technical documentation to get the default
configurations of the various Signaling Types.
* Enable: The interface uses the specific signaling
configuration as defined in the current row. To retrieve
the default configuration associated with the current
Signaling Type, the command implemented by the
ResetSpecific parameter MUST be issued.
"
DEFVAL { disable }
::= { eamToneVariantsEntry 200 }
-- Columnar:KP (start-of-pulsing) Tone
eamToneVariantsKpTone OBJECT-TYPE
SYNTAX INTEGER { none(100) , mF0(200) , mF1(300) , mF2(400) , mF3
(500) , mF4(600) , mF5(700) , mF6(800) , mF7(900) , mF8(1000)
, mF9(1100) , mF10(1200) , mF11(1300) , mF12(1400) , mF13
(1500) , mF14(1600) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " KP (start-of-pulsing) Tone
Specifies the KP (start-of-pulsing) signal.
* None : No tone used.
* MF0..MF14 : MF R1 Tone
"
DEFVAL { mF10 }
::= { eamToneVariantsEntry 300 }
-- Columnar:ST (end-of-pulsing) Tone
eamToneVariantsStTone OBJECT-TYPE
SYNTAX INTEGER { none(100) , mF0(200) , mF1(300) , mF2(400) , mF3
(500) , mF4(600) , mF5(700) , mF6(800) , mF7(900) , mF8(1000)
, mF9(1100) , mF10(1200) , mF11(1300) , mF12(1400) , mF13
(1500) , mF14(1600) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " ST (end-of-pulsing) Tone
Specifies the ST (end-of-pulsing) signal.
* None : No tone used.
* MF0..MF14 : MF R1 Tone
"
DEFVAL { mF13 }
::= { eamToneVariantsEntry 400 }
-- Row command:Reset Specific
eamToneVariantsResetSpecific OBJECT-TYPE
SYNTAX INTEGER { noOp(0), resetSpecific(10) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Reset Specific
Resets specific settings of E&M Tones parameters with the
default signaling settings. This command is used to retrieve
the default signaling configuration set in the SignalingType
parameter.
"
DEFVAL { noOp }
::= { eamToneVariantsEntry 900 }
-- End of table:E&M Signaling Tone Variants
-- End of group:E&M Configuration
-- ****************************************************************************
-- Group:Bearer Channel Configuration
-- ****************************************************************************
bearerChannelGroup OBJECT IDENTIFIER
::= { eamMIBObjects 200 }
-- ***************************************************************************
-- Table:Bearer Channel Info
-- ***************************************************************************
bearerChannelInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF BearerChannelInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " Bearer Channel Info
Port-specific operational, statistics, and active call data
for B channels.
"
::= { bearerChannelGroup 100 }
bearerChannelInfoEntry OBJECT-TYPE
SYNTAX BearerChannelInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table Bearer Channel Info. "
INDEX {
bearerChannelInfoIndex
}
::= { bearerChannelInfoTable 1 }
BearerChannelInfoEntry ::= SEQUENCE
{
bearerChannelInfoIndex OCTET STRING,
bearerChannelInfoState INTEGER
}
-- Index:Index
bearerChannelInfoIndex OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Index
Identifies the Bearer Channel..
"
::= { bearerChannelInfoEntry 100 }
-- Columnar:State
bearerChannelInfoState OBJECT-TYPE
SYNTAX INTEGER { idle(100) , inUse(200) , maintenance(300) , error
(400) , disabled(500) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION " State
The current call control state for this channel:
* Idle: The channel is available
* InUse: The channel is currently used
* Maintenance: Maintenance state, temporarily unavailable
* Error: Error on this channel
* Disabled: The channel is disabled
"
::= { bearerChannelInfoEntry 200 }
-- End of table:Bearer Channel Info
-- End of group:Bearer Channel Configuration
-- ****************************************************************************
-- Group:Signaling Channel Configuration
-- ****************************************************************************
physicalGroup OBJECT IDENTIFIER
::= { eamMIBObjects 300 }
-- ***************************************************************************
-- Table:Physical Link Information
-- ***************************************************************************
physicalLinkInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhysicalLinkInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " Physical Link Information
The physical link information table contains status
information for all interfaces on this managed device.
"
::= { physicalGroup 100 }
physicalLinkInfoEntry OBJECT-TYPE
SYNTAX PhysicalLinkInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table Physical Link Information. "
INDEX {
physicalLinkInfoInterfaceName
}
::= { physicalLinkInfoTable 1 }
PhysicalLinkInfoEntry ::= SEQUENCE
{
physicalLinkInfoInterfaceName OCTET STRING,
physicalLinkInfoState INTEGER
}
-- Index:Interface Name
physicalLinkInfoInterfaceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Interface Name
Identifies the interface.
"
::= { physicalLinkInfoEntry 100 }
-- Columnar:State
physicalLinkInfoState OBJECT-TYPE
SYNTAX INTEGER { up(100) , down(200) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION " State
The layer 1 state for this interface:
* Up: Layer 1 connectivity.
* Down: No layer 1 connectivity. The interface might be in
this state because no cable is plugged in or a pinout
problem is detected.
"
::= { physicalLinkInfoEntry 200 }
-- End of table:Physical Link Information
-- ***************************************************************************
-- Table:Physical Link
-- ***************************************************************************
physicalLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhysicalLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " Physical Link
The physical link table containing configuration and
operational parameters for all interfaces on this managed
device.
"
::= { physicalGroup 200 }
physicalLinkEntry OBJECT-TYPE
SYNTAX PhysicalLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " A row in table Physical Link. "
INDEX {
physicalLinkInterfaceName
}
::= { physicalLinkTable 1 }
PhysicalLinkEntry ::= SEQUENCE
{
physicalLinkInterfaceName OCTET STRING,
physicalLinkLineCoding INTEGER,
physicalLinkLineFraming INTEGER,
physicalLinkClockMode INTEGER,
physicalLinkMonitorLinkStateEnable MxEnableState,
physicalLinkPortPinout INTEGER
}
-- Index:Interface Name
physicalLinkInterfaceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Interface Name
Identifies the interface.
"
::= { physicalLinkEntry 100 }
-- Columnar:Line Coding
physicalLinkLineCoding OBJECT-TYPE
SYNTAX INTEGER { b8zs(100) , hdb3(200) , ami(300) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Line Coding
Defines the transmission encoding of bits:
* B8ZS: Bipolar with 8-Zeros Substitution (T1 lines)
* HDB3: High-Density Bipolar with 3-zeros (E1 lines)
* AMI: Alternate Mark Inversion (E1 and T1 lines)
For further information, see ITU-T Recommendation G.703.
"
DEFVAL { b8zs }
::= { physicalLinkEntry 200 }
-- Columnar:Line Framing
physicalLinkLineFraming OBJECT-TYPE
SYNTAX INTEGER { sf(100) , esf(200) , crc4(300) , noCrc4(400) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Line Framing
Defines the frame format:
* SF: Super frame. Sometimes known as D4 (T1 lines)
* ESF: Extended super frame (T1 lines)
* CRC4: Cyclic redundancy check 4 (E1 lines)
* NO-CRC4: No Cyclic redundancy check 4 (E1 lines)
For further information, see ITU-T Recommendation G.704.
"
DEFVAL { esf }
::= { physicalLinkEntry 300 }
-- Columnar:Clock Mode
physicalLinkClockMode OBJECT-TYPE
SYNTAX INTEGER { master(100) , slave(200) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Clock Mode
A port can either generate the clocking for the line or
accept the clock from the line. The options master or slave
determine the clocking method:
* Master: Generates clock
* Slave: Accepts clock
"
DEFVAL { slave }
::= { physicalLinkEntry 400 }
-- Columnar:Monitor Link State Enable
physicalLinkMonitorLinkStateEnable OBJECT-TYPE
SYNTAX MxEnableState
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Monitor Link State Enable
Monitors the physical link state of an E&M interface.
Enable: An E&M endpoint's operational state is affected by
its interface physical link state. When the link state of an
E&M interface is down, the operational state of its matching
endpoint becomes 'disable'.
Disable: An E&M endpoint's operational state is not affected
by its interface physical link state.
"
DEFVAL { enable }
::= { physicalLinkEntry 500 }
-- Columnar:Port Pinout
physicalLinkPortPinout OBJECT-TYPE
SYNTAX INTEGER { auto(100) , master(200) , slave(300) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Port Pinout
Defines the port pinout:
* Auto: The pinout is set according to the clock mode.
* Master: Force the pinout to Master regardless of the
clock mode.
* Slave: Force the pinout to Slave regardless of the clock
mode.
See the PhysicalLink.ClockMode parameter for a description of
the clock mode.
"
DEFVAL { auto }
::= { physicalLinkEntry 600 }
-- End of table:Physical Link
-- End of group:Signaling Channel Configuration
-- ****************************************************************************
-- Group:Automatic Configuration
-- ****************************************************************************
autoConfigure OBJECT IDENTIFIER
::= { eamMIBObjects 400 }
-- Scalar:Auto Configure Status
autoConfigureStatus OBJECT-TYPE
SYNTAX INTEGER { idle(100) , sensing(200) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Auto Configure Status
Indicates the current status of the E&M automatic
configuration mechanism.
* Idle: The automatic configuration mechanism is ready to be
started.
* Sensing: The automatic configuration mechanism is
currently started and is testing different E&M
configurations to obtain a link up.
"
::= { autoConfigure 100 }
-- Scalar:Last Auto Configure Result
lastAutoConfigureResult OBJECT-TYPE
SYNTAX INTEGER { none(100) , success(200) , fail(300) , aborted(400)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Last Auto Configure Result
Result of the last E&M automatic configuration.
* None: No result is available.
* Success: The last automatic configuration succeeded.
* Fail: The last automatic configuration failed.
* Aborted: The last automatic configuration has been
cancelled by the user.
"
::= { autoConfigure 200 }
-- End of group:Automatic Configuration
-- ****************************************************************************
-- Group:Notification Messages Configuration
-- ****************************************************************************
notificationsGroup OBJECT IDENTIFIER
::= { eamMIBObjects 60010 }
-- Scalar:Minimal Severity of Notification
minSeverity OBJECT-TYPE
SYNTAX INTEGER { disable(0) , debug(100) , info(200) , warning(300) ,
error(400) , critical (500) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION " Minimal Severity of Notification
Sets the minimal severity to issue a notification message
incoming from this service.
* Disable: No notification is issued.
* Debug: All notification messages are issued.
* Info: Notification messages with a 'Informational' and
higher severity are issued.
* Warning: Notification messages with a 'Warning' and higher
severity are issued.
* Error: Notification messages with an 'Error' and higher
severity are issued.
* Critical: Notification messages with a 'Critical' severity
are issued.
"
DEFVAL { warning }
::= { notificationsGroup 100 }
-- End of group:Notification Messages Configuration
-- ****************************************************************************
-- Group:Configuration Settings
-- ****************************************************************************
configurationGroup OBJECT IDENTIFIER
::= { eamMIBObjects 60020 }
-- Scalar:Need Restart
needRestartInfo OBJECT-TYPE
SYNTAX INTEGER { no(0) , yes(100) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Need Restart
Indicates if the service needs to be restarted for the
configuration to fully take effect.
* Yes: Service needs to be restarted.
* No: Service does not need to be restarted.
Services can be restarted by using the
Scm.ServiceCommands.Restart command.
"
::= { configurationGroup 100 }
-- End of group:Configuration Settings
END