383 lines
12 KiB
Plaintext
Executable File
383 lines
12 KiB
Plaintext
Executable File
--/******************************************************************************
|
|
--*
|
|
--* INTEL CORPORATION PROPRIETARY INFORMATION
|
|
--* This software is supplied under the terms of a license agreement or
|
|
--* nondisclosure agreement with Intel Corporation and may not be copied
|
|
--* or disclosed except in accordance with the terms of that agreement.
|
|
--* Copyright (c) 2001 Intel Corporation. All Rights Reserved.
|
|
--*
|
|
--*
|
|
--******************************************************************************/
|
|
|
|
--/******************************************************************************
|
|
-- *
|
|
-- * Revision History:
|
|
-- *
|
|
-- * GAE - 01/24/11 Timer Expired watchdog 2, Power supply presence,
|
|
-- * Power unit, SMI timeout, Drive slot.
|
|
-- * GAE - 03/24/09 Changed "Thurley" to "Common."
|
|
-- * edy - 10/13/08 removed unneeded variables
|
|
-- *
|
|
-- *****************************************************************************/
|
|
|
|
INTEL-COMMON-BMC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Title : BMC 1.0 MIB file.
|
|
|
|
IMPORTS
|
|
enterprises
|
|
FROM RFC1155-SMI
|
|
TRAP-TYPE
|
|
FROM RFC-1215;
|
|
|
|
-- textual conventions
|
|
-- MODULE IDENTIFICATION
|
|
--
|
|
-- COMMENT: module-identity, last-updated, etc are MIB keywords, but are v2
|
|
-- BMC Alerting MODULE-IDENTITY
|
|
-- LAST-UPDATED "January 24, 2011"
|
|
-- ORGANIZATION "Intel Corporation"
|
|
-- CONTACT-INFO
|
|
-- " Server Management Firmware Development,
|
|
-- Intel Corporation, JF5
|
|
-- Hillsboro, OR 97124"
|
|
-- DESCRIPTION
|
|
-- "This is the MIB file for the Embedded Server Management SNMP Agent."
|
|
|
|
wired-for-management OBJECT IDENTIFIER ::= {enterprises 3183}
|
|
pet OBJECT IDENTIFIER ::= {wired-for-management 1}
|
|
--**************************************************************************
|
|
--* Notifications (using SNMPv1 TRAP-TYPE constructs for maximum
|
|
--* compatibility with deployed SNMP managers).
|
|
--**************************************************************************
|
|
|
|
pet-events OBJECT IDENTIFIER ::= {pet 1}
|
|
--**************************************************************************
|
|
-- Temperature Sensor Events (2 of them)
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (010107h == 65799)
|
|
tempUpperNonCriticalGoingHigh TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Temperature sensor crossed upper non-critical threshold, going high."
|
|
::= 65799
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (010109h == 65801)
|
|
tempUpperCriticalGoingHigh TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Temperature sensor crossed upper critical threshold, going high."
|
|
::= 65801
|
|
|
|
|
|
--**************************************************************************
|
|
-- Voltage Sensor Events (4 of them)
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (020100h == 131328)
|
|
voltageLowerNonCriticalGoingLow TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Voltage sensor crossed lower non-critical threshold, going low."
|
|
|
|
::= 131328
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (020102h == 131330)
|
|
voltageLowerCriticalGoingLow TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Voltage sensor crossed lower critical threshold, going low."
|
|
::= 131330
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (020107h == 131335)
|
|
voltageUpperNonCriticalGoingHigh TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Voltage sensor crossed upper non-critical threshold, going high."
|
|
::= 131335
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (020109h == 131337)
|
|
voltageUpperCriticalGoingHigh TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Voltage sensor crossed upper critical threshold, going high."
|
|
::= 131337
|
|
|
|
|
|
--**************************************************************************
|
|
-- Fan Failure Events (2 of them)
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (040100h == 262400)
|
|
fanFailureLowerNonCriticalGoingLow TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Fan sensor crossed lower non-critical threshold, going low."
|
|
::= 262400
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (040102h == 262402)
|
|
fanFailureLowerCriticalGoingLow TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Fan sensor crossed lower critical threshold, going low."
|
|
|
|
::= 262402
|
|
|
|
|
|
--**************************************************************************
|
|
-- Chassis Intrusion Event
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type 05h, Event Type 6fh, Event Offset 00h (056f00h == 356096)
|
|
chassisIntrusionEvent TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"A Chassis Intrusion assertion event."
|
|
|
|
::= 356096
|
|
|
|
-- Event Sensor Type 05h, Event Type 6fh, Event Offset 04h (056f04h == 356100)
|
|
chassisIntrusionEventLANLeashLost TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"A Chassis Intrusion LAN leash lost assertion event."
|
|
|
|
::= 356100
|
|
--**************************************************************************
|
|
-- Power Supply Fault Events (5 of them)
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (086F00h == 552704)
|
|
powerSupplyPresence TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power supply presence event."
|
|
::= 552704
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (086F01h == 552705)
|
|
powerSupplyFailure TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power supply failure event."
|
|
::= 552705
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (086F02h == 552706)
|
|
powerSupplyPredictiveFailure TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power supply predictive failure asserted event."
|
|
::= 552706
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (086F03h == 552707)
|
|
powerSupplyACLost TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power supply A/C lost event."
|
|
::= 552707
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (086F06h == 552710)
|
|
powerSupplyConfigurationError TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power supply configuration error event."
|
|
::= 552710
|
|
|
|
--**************************************************************************
|
|
-- Uncorrectable ECC Error Event
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (0C6F01h == 814849)
|
|
uncorrectableECCError TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Uncorrectable ECC error event."
|
|
|
|
::= 814849
|
|
|
|
--**************************************************************************
|
|
-- POST Error Event
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (0F6F00h == 1011456)
|
|
postError TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power On Self Test (POST) error event."
|
|
|
|
::= 1011456
|
|
|
|
--**************************************************************************
|
|
-- Processor Failure Events (4 of them)
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (076F01h == 487169)
|
|
thermalTripError TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Thermal Trip error event."
|
|
::= 487169
|
|
|
|
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (076F07h == 487175)
|
|
cpuPresence TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Processor Presence"
|
|
|
|
::= 487175
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (070301h == 459521)
|
|
procDisabledError TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"CATERR Event Detected."
|
|
::= 459521
|
|
|
|
--**************************************************************************
|
|
-- Critical Interrupt Events (1 of them)
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (136F00h == 1273600)
|
|
fatalNMIError TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Front Panel NMI Assertion event."
|
|
::= 1273600
|
|
|
|
--**************************************************************************
|
|
-- Watchdog 2 Events (5 of them)
|
|
--**************************************************************************
|
|
-- Event Sensor Type, Event Type, Event Offset (236F00h == 2322176)
|
|
timerExpired TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Timer expired event."
|
|
::= 2322176
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (236F01h == 2322177)
|
|
hardReset TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Hard reset event."
|
|
::= 2322177
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (236F02h == 2322178)
|
|
powerDown TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power down event."
|
|
::= 2322178
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (236F03h == 2322179)
|
|
powerReset TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power Reset event"
|
|
::= 2322179
|
|
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (236F08h == 2322184)
|
|
timerInterrupt TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Timer Interrupt event."
|
|
::= 2322184
|
|
|
|
--**************************************************************************
|
|
-- System Event
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (126F01h == 1208065)
|
|
oemSystemBootEvent TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"OEM System Boot event."
|
|
::= 1208065
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (106F02h == 1076994)
|
|
selLogAreaReset TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Log area reset / cleared"
|
|
::=1076994
|
|
|
|
|
|
--**************************************************************************
|
|
-- SMI Timeout
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (03F301h == 258817)
|
|
smiTimeoutError TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"SMI Timeout Assertion event."
|
|
::= 258817
|
|
|
|
--**************************************************************************
|
|
-- Drive Slot (Bay) Offsets (4)
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (0D6F00h == 880384)
|
|
drivePresence TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Drive Presence event."
|
|
::= 880384
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (0D6F01h == 880385)
|
|
driveFault TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Drive Fault event."
|
|
::= 880385
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (0D6F02h == 880386)
|
|
drivePredictiveFailure TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Drive Predictive Failure event."
|
|
::= 880386
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (0D6F07h == 880391)
|
|
driveRebuild TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Drive Rebuild event."
|
|
::= 880391
|
|
|
|
--**************************************************************************
|
|
-- Power Unit Offsets (4)
|
|
--**************************************************************************
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (096F00h == 618240)
|
|
powerOffPowerUnit TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power Unit Power Off event."
|
|
::= 618240
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (096F04h == 618244)
|
|
acLostPowerUnit TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power Unit AC Lost event."
|
|
::= 618244
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (096F05h == 618245)
|
|
softPowerControlPowerUnit TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power Unit Soft Power Control Failure event."
|
|
::= 618245
|
|
|
|
-- Event Sensor Type, Event Type, Event Offset (096F06h == 618246)
|
|
powerUnitFailure TRAP-TYPE
|
|
ENTERPRISE pet-events
|
|
DESCRIPTION
|
|
"Power Unit Failure event."
|
|
::= 618246
|
|
|
|