Observium_CE/mibs/infinera/INFINERA-ENTITY-PEM-MIB

162 lines
4.1 KiB
Plaintext

-- ***************************************************************
-- INFINERA-ENTITY-PEM-MIB
--
-- October 2008, Sharfuddin Syed / Narendra Gupta
--
--
-- Copyright (c) 2008-2012 by Infinera Inc.
-- All rights reserved.
-- ****************************************************************
INFINERA-ENTITY-PEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, Integer32, Unsigned32 FROM SNMPv2-SMI
OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF
DisplayString FROM SNMPv2-TC
entLPPhysicalIndex FROM ENTITY-MIB
equipment FROM INFINERA-REG-MIB
InfnEqptType,FloatTenths FROM INFINERA-TC-MIB;
pemMIB MODULE-IDENTITY
LAST-UPDATED "200810200000Z"
ORGANIZATION
"INFINERA"
CONTACT-INFO
"Infinera
169 Java Drive
Sunnyvale, CA - 94089
Contact : Technical Support
Email : support@infinera.com
Phone : 1-877-INF-5288"
DESCRIPTION
"This MIB is modeling for PEM equipment table."
::= { equipment 15 }
pemConformance OBJECT IDENTIFIER ::= { pemMIB 3 }
pemCompliances OBJECT IDENTIFIER ::= { pemConformance 1 }
pemGroups OBJECT IDENTIFIER ::= { pemConformance 2 }
pemTable OBJECT-TYPE
SYNTAX SEQUENCE OF PemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains all PEM modules that are currently present in a network element.
"
::= { pemMIB 1 }
pemEntry OBJECT-TYPE
SYNTAX PemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the PEM table. Each row in the table is identified with a unique entPhysicalIndexID.
"
INDEX { entLPPhysicalIndex }
::= { pemTable 1 }
PemEntry ::= SEQUENCE {
pemMoId DisplayString,
pemProvEqptType InfnEqptType,
provRatingAmps Unsigned32,
installedRatingAmps Unsigned32,
underVoltageThreshold FloatTenths,
overVoltageThreshold FloatTenths,
transientVoltageThreshold FloatTenths,
inputVoltage Integer32
}
pemMoId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the primary Key of the objects e.g 1-IOSHELF-PEMA, 1-IOSHELF-PEMB etc."
::= { pemEntry 1 }
pemProvEqptType OBJECT-TYPE
SYNTAX InfnEqptType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configured PEM type."
::= { pemEntry 2 }
provRatingAmps OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Provisioned Rating AMPs."
::= { pemEntry 3 }
installedRatingAmps OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Installed rating Amps."
::= { pemEntry 4 }
underVoltageThreshold OBJECT-TYPE
SYNTAX FloatTenths
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"voltage under minimum threshold"
::= { pemEntry 5 }
overVoltageThreshold OBJECT-TYPE
SYNTAX FloatTenths
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"high voltage threshold"
::= { pemEntry 6 }
transientVoltageThreshold OBJECT-TYPE
SYNTAX FloatTenths
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transient voltage threshold value"
::= { pemEntry 7 }
inputVoltage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { pemEntry 8 }
pemCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
""
MODULE
MANDATORY-GROUPS { pemGroup }
::= { pemCompliances 1 }
pemGroup OBJECT-GROUP
OBJECTS {
pemMoId,
pemProvEqptType,
provRatingAmps,
installedRatingAmps,
underVoltageThreshold,
overVoltageThreshold,
transientVoltageThreshold,
inputVoltage
}
STATUS current
DESCRIPTION
""
::= { pemGroups 1 }