Observium_CE/mibs/huawei/ISM-HUAWEI-OID-BASED-TRAP-MIB

4373 lines
266 KiB
Plaintext

--
-- ISM-HUAWEI-OID-BASED-TRAP-MIB.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 347
-- Wednesday, March 02, 2016 at 22:48:04
--
-- ISM-HUAWEI-OID-BASED-TRAP-MIB.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 347
-- Saturday, February 27, 2016 at 15:04:41
--
-- ISM-HUAWEI-MIB.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 347
-- Thursday, March 27, 2014 at 11:36:30
--
ISM-HUAWEI-OID-BASED-TRAP-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwinfoFaultNotificationType, hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle,
hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo,
hwIsmReportingAlarmAdditionInfo, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmLocationAlarmID, isoConformance, basicCompliance
FROM ISM-HUAWEI-MIB
NOTIFICATION-GROUP
FROM SNMPv2-CONF
MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI;
-- 1.3.6.1.4.1.2011.2.91.10.2.1.15
-- March 06, 2013 at 10:10 GMT
-- September 17, 2008 at 16:29 GMT
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1
oidBasedTrap MODULE-IDENTITY
LAST-UPDATED "201303061010Z" -- March 06, 2013 at 10:10 GMT
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com"
DESCRIPTION
"Description."
REVISION "200809171629Z" -- September 17, 2008 at 16:29 GMT
DESCRIPTION
"V1R1
V1R2"
::= { hwinfoFaultNotificationType 1 }
--
-- Node definitions
--
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15
storage OBJECT IDENTIFIER ::= { oidBasedTrap 15 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6
port OBJECT IDENTIFIER ::= { storage 6 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.9
ethFCoEPortIsDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"ETH/FCoE Port Link Down."
::= { port 9 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.17
portIsWorkingInHalfDuplexMode NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Network Port Is Working In Half-Duplex Mode."
::= { port 17 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.20
expPortHasTooManyBitErrors NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Port Has Too Many Bit Errors."
::= { port 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.21
hostPortHasTooManyBitErrors NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Host Port Has Too Many Bit Errors."
::= { port 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.22
pciePortIsPartiallyDamaged NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"PCIe Port Partially Damaged."
::= { port 22 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.25
pciePortIsDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"PCIe Port Disconnected."
::= { port 25 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.6
expansionPortPartiallyDamaged NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Port Partially Damaged."
::= { port 6 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.2
expansionPortIsDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Port Link Down."
::= { port 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.29
rateIsSmallerThanAllowedMaximum NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Port Negotiated Rate Is Smaller Than The Allowed Maximum."
::= { port 29 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.15
portNegotiatedRateNotToMaximum NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Negotiated Rate Of A Port Is Smaller Than The Allowed Maximum."
::= { port 15 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.4
hostPortIsDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Host Port Link Down."
::= { port 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.73
manageNetworkPortIsDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Management Network Port Is Disconnected."
::= { port 73 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.16
expansionPortIsolated NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Port Isolated."
::= { port 16 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.11
managementNetworkPortIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Management Network Port Is Faulty."
::= { port 11 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.14
pciePortIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"PCIe Port Is Faulty."
::= { port 14 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.13
hostPortIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Host Port Is Faulty."
::= { port 13 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.12
expansionPortIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Port Is Faulty."
::= { port 12 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10
disk OBJECT IDENTIFIER ::= { storage 10 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.269
numberOfDisksExceedsUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Disks Exceeds The Upper Limit."
::= { disk 269 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.259
mixtureOfSATAAndNonSATADisks NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SATA Disks And Non-SATA Disks Mixed."
::= { disk 259 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.91
diskIsIsolated NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Hard Disk Is Isolated."
::= { disk 91 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.95
slowDiskResponse NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Slow Disk Response."
::= { disk 95 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.155
authenticationOfSEDAccessFails NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Authenticate Self-Encrypting Disk Access."
::= { disk 155 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.8
cofferDiskIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Coffer Disk Is Faulty."
::= { disk 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.9
cofferDiskFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Faulty Coffer."
::= { disk 9 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.20
diskInEngineMonitoringFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The System Failed To Monitor A Disk In The Controller Enclosure."
::= { disk 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.21
diskMonitoringFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The System Failed To Monitor A Disk In A Disk Enclosure."
::= { disk 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.275
diskModelIsIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Incompatible Disk Model."
::= { disk 275 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.274
diskInSingleLinkState NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Is In Single Link State."
::= { disk 274 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.273
diskIsAboutToFail NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Is About To Fail."
::= { disk 273 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.279
cofferDiskModelIsIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Coffer Disk Type Is Not Supported."
::= { disk 279 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.4
diskTemperatureExceedsUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Temperature Exceeds The Upper Limit."
::= { disk 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.79
cofferDiskInInccorrectSlot NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Coffer Disk Is Inserted Into An Incorrect Slot."
::= { disk 79 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.132
diskIsRejectedBySystem NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Disk Is Rejected By The System."
::= { disk 132 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.10
cofferDisksNotFound NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Coffer Disks Not Found."
::= { disk 10 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.258
authenticationOfSEDKeyFails NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Authenticate A Self-Encrypting Disk Key."
::= { disk 258 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.271
diskHardwareIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Is Faulty."
::= { disk 271 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.272
diskIsUnrecognizable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Unrecognizable Disk."
::= { disk 272 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.149
svpDiskIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP Disk Is Faulty."
::= { disk 149 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.148
svpDiskIsNotInserted NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP Disk Is Not Inserted."
::= { disk 148 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11
lun OBJECT IDENTIFIER ::= { storage 11 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.258
externalLunTypeChanged NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"External LUN Is Changed To Command Device."
::= { lun 258 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.268
lunStartBgrTaskFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"LUN Start Bgr Task Failed."
::= { lun 268 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.267
localArrayRegPathToHeteroFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Register Paths From The Local Storage Array To Heterogeneous Storage Array."
::= { lun 267 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.2
theLUNHasMediumError NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"LUN Has A Medium Error."
::= { lun 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.81
theLUNLBAHasWarningMediumError NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"LUN Has A Medium Error."
::= { lun 81 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.80
theLUNLBAHasCriticalMediumError NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"LUN Has A Medium Error."
::= { lun 80 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.269
snapshotLUNIsFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Snapshot LUN Is Faulty."
::= { lun 269 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.101
externalLUNFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"External LUN Faulty."
::= { lun 101 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.99
externalLUNToOnlyOneController NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"External LUN Has Links To Only One Controller."
::= { lun 99 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.264
remoteLinkExceedUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of The Connected Remote Links Has Exceeded The Upper Limit ."
::= { lun 264 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.265
remoteArrayExceedUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of The Connected Remote Arrays Has Exceeded The Upper Limit."
::= { lun 265 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.82
incompatibleArrayConnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Incompatible Heterogeneous Array Connected To The System."
::= { lun 82 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.270
theLUNIsFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"LUN Is Faulty."
::= { lun 270 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.98
iscsiLinkFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"ISCSI Link Of Heterogeneous Array Faulty."
::= { lun 98 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.97
fcLinkFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"FC Link Of Heterogeneous Array Faulty."
::= { lun 97 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.96
iscsiLinkDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"ISCSI Link Of Heterogeneous Array Disconnected."
::= { lun 96 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.93
fcLinkDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"FC Link Of Heterogeneous Array Disconnected."
::= { lun 93 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.1
theLUNIsFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"LUN Is Faulty."
::= { lun 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.61
snapshotLUNIsFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Snapshot LUN Is Faulty."
::= { lun 61 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.21
host OBJECT IDENTIFIER ::= { storage 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.21.25
noRedundantConnectionToHost NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Host Is Not Redundantly Connected To Storage Arrays."
::= { host 25 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.21.26
aLinkToHostIsDown NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Link Between A Host And Storage Array Is Down."
::= { host 26 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.21.29
ultrapathIncompatibleWithStorage NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Ultrapath Incompatible With Storage Array Software."
::= { host 29 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23
power OBJECT IDENTIFIER ::= { storage 23 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.25
powerModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Power Module Is Faulty."
::= { power 25 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.5
powerModuleInputIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Power Module Input Is Abnormal."
::= { power 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.21
powerModulesTypesDifferent NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Power Modules Of Different Types Are Used In A Disk Enclosure."
::= { power 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.22
diskEnclHasNoRePowerModule NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A Disk Enclosure Does Not Have A Redundant Power Module."
::= { power 22 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.24
powerModuleIsIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Power Module Type Is Mismatched."
::= { power 24 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.23
failedToMonitorAPowerModule NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The System Failed To Monitor A Power Module."
::= { power 23 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.2
powerModuleIsRemoved NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Power Module Is Removed."
::= { power 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.3
powerModuleFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Power Module Is Faulty."
::= { power 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.20
powerModuleHasNoInput NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Power Module Has No Input."
::= { power 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.4
powerModuleTempExceedsLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Power Module Temperature Exceeds The Upper Limit."
::= { power 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.27
snapshot OBJECT IDENTIFIER ::= { storage 27 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.27.1
snapshotStopAbnormally NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Snapshot Stops Abnormally."
::= { snapshot 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.27.2
snapshotUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Snapshot Unavailable."
::= { snapshot 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.27.3
failedToDisableTheSnapshot NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Disable The Snapshot."
::= { snapshot 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40
filesystem OBJECT IDENTIFIER ::= { storage 40 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.289
fsObjectIsIsolated NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"An Object In File System Is Isolated."
::= { filesystem 289 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.288
fsRemainCapacityIsInsufficient NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remaining Capacity In A File System Is Insufficient."
::= { filesystem 288 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.290
fileSystemExistMediumError NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Medium Errors In The File System."
::= { filesystem 290 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.291
fileOrDirExistMediumError NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Medium Errors In The File Or The Directory."
::= { filesystem 291 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.287
openedFilesNumAboutToExceedThres NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Opened Files On A Controller Is About To Exceed The Upper Limit."
::= { filesystem 287 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.282
filesNumAboutToExceedThreshold NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Files In A File System Is About To Exceed The Upper Limit."
::= { filesystem 282 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.284
filesNumExceedLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Files In A File System Has Reached Or Exceeded The Upper Limit."
::= { filesystem 284 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.286
openedFilesNumExceedLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Opened Files On A Controller Has Reached Or Exceeded The Upper Limit."
::= { filesystem 286 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.274
filesNumAboutToExceedLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Files In A File System Is About To Exceed The Upper Limit."
::= { filesystem 274 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.275
dirFilesNumAboutToExceedLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Files In A Directory Of A File System Is About To Exceed The Upper Limit."
::= { filesystem 275 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.278
filesNumReachedOrExceededLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Files In A File System Has Reached Or Exceeded The Upper Limit."
::= { filesystem 278 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.279
dirFilesNumExceededLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Files In A Directory Of A File System Has Reached Or Exceeded The Upper Limit."
::= { filesystem 279 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.280
openedFilesNumExceededLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Opened Files On A Controller Has Reached Or Exceeded The Upper Limit."
::= { filesystem 280 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.285
subFilesNumToExceedLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Files Under A Directory Of A File System Has Reached Or Exceeded The Upper Limit."
::= { filesystem 285 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.283
subFilesNumAboutToExceedLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Files Under A Directory Of A File System Is About To Exceed The Upper Limit."
::= { filesystem 283 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.116
fileSystemMetadataIsDamaged NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"File System Metadata Corrupted."
::= { filesystem 116 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.118
fileOrDirDamagedInFs NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"File Or Directory Corrupted."
::= { filesystem 118 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.69
fileSystemIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"File System Is Faulty."
::= { filesystem 69 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.117
writeProtectionIsEnabledForFS NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"File System Under Write Protection."
::= { filesystem 117 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.49
event OBJECT IDENTIFIER ::= { storage 49 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.49.4
eventAmountReachUpLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Space That Stores Event Logs Is To Be Used Up."
::= { event 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201
system OBJECT IDENTIFIER ::= { storage 201 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.21
controllerWriteCacheIsDisabled NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Write Cache Is Disabled."
::= { system 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.335
dnsIsUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Management DNS Server Is Unavailable."
::= { system 335 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.317
ipaddrConflict NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"IP Address Conflict."
::= { system 317 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.86
onlyOneClusterLinkIsAvailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Only One Cluster Link Is Available."
::= { system 86 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.6
systemEnterSafeMode NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The System Has Entered Safe Mode."
::= { system 6 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202
user OBJECT IDENTIFIER ::= { storage 202 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.8
userInfoNeedReview NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Super Administrator Needs To Review User Account Information."
::= { user 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.15
passwdOfUserHasExpired NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Password Of The User Has Expired."
::= { user 15 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.14
passwdOfUserIsAboutToExpire NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Password Of The User Is About To Expire."
::= { user 14 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.17
passwdOfUserHasExpired NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Password Of The User Has Expired."
::= { user 17 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.16
passwdOfUserIsAboutToExpire NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Password Of The User Is About To Expire ."
::= { user 16 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206
enclosure OBJECT IDENTIFIER ::= { storage 206 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.49
enclosureIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Faults Occurred On An Enclosure."
::= { enclosure 49 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.46
failedToMonitorTheRearPanel NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The System Failed To Monitor The Rear Panel Of The Enclosure."
::= { enclosure 46 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.43
highDensityAreMixConnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"From An Expansion Port, Disk Enclosures And High-Density Disk Enclosures Are Mix-Connected."
::= { enclosure 43 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.23
numOfEnclOnExpPortExceedsLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Number Of Disk Enclosures Connected To An Expansion Port Exceeds The System Specification."
::= { enclosure 23 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.4
failedToIdentifyEnclosure NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Identify A Controller Enclosure Or Disk Enclosure."
::= { enclosure 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.50
enclosureIsUnrecognizable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Identify A Controller Enclosure Or Disk Enclosure."
::= { enclosure 50 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.51
enclosureCablingIsIncorrect NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Incorrect Configuration Disk Enclosure Cabling."
::= { enclosure 51 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.20
faultsOccurredOnEnclosure NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Faults Occurred On An Enclosure."
::= { enclosure 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.5
diskEnclTempExceedsUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Enclosure Temperature Exceeds The Upper Limit."
::= { enclosure 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.7
diskEnclTempIsBelowLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Engine Or Disk Enclosure Temperature Is Below The Lower Limit."
::= { enclosure 7 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.8
ctrlEnclTempExceedsUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Enclosure Temperature Exceeds The Upper Limit."
::= { enclosure 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.9
ctrlEnclTempIsFarBeyondUpLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Enclosure Temperature Is Far Beyond The Upper Limit."
::= { enclosure 9 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.10
diskEnclTempIsFarBeyondUpLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Enclosure Temperature Is Far Beyond The Upper Limit."
::= { enclosure 10 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.52
enclSpeedSmallerThanLoopSpeed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Disk Enclosure Speed Does Not Reach The Maximum Loop Speed."
::= { enclosure 52 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.15
anUnsupportedExpEnclConnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Is Connected To An Unsupported Disk Enclosure."
::= { enclosure 15 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.42
diskEnclosureIsSingleLink NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Enclosure Is Working In Single Link State."
::= { enclosure 42 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.1
failedToMonitorADiskEnclosure NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Monitor A Disk Enclosure."
::= { enclosure 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207
controller OBJECT IDENTIFIER ::= { storage 207 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.20
monitorControllerFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Monitor The Controller."
::= { controller 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.5
abnormalCommunicateBetweenCtrls NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Abnormal Communication Between Controllers."
::= { controller 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.74
controllerCannotBeMonitored NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Some Statuses Of A Controller Cannot Be Monitored."
::= { controller 74 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.54
controllerServicesAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Services Are Abnormal."
::= { controller 54 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.95
controllerIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Is Faulty."
::= { controller 95 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.108
bbuIsFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The BBU Module Of The Controller Is About To Expire."
::= { controller 108 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.97
ctrlAndMgtCommunicateLinkFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Communication Link Fault Among The Controller And Management Modules."
::= { controller 97 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.104
controllerIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Is Faulty."
::= { controller 104 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.105
controllerIsOffline NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Is Offline."
::= { controller 105 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.23
portIsIncorrectlyConnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Incorrect Connection Between A Controller Port And A Switch Port."
::= { controller 23 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.6
controllerIsRemoved NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Is Removed."
::= { controller 6 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.57
theCoinBatteryIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Coin Battery Is Faulty."
::= { controller 57 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.2
ftpServiceIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The FTP Service Is Abnormal."
::= { controller 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.11
processCpuUsageIsTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Process CPU Usage Is Too High."
::= { controller 11 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.1
sshServiceIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The SSH Service Is Abnormal."
::= { controller 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.98
bbuIsFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Backup Power Module Of The Controller Is About To Expire ."
::= { controller 98 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.9
ntpSynchronizationIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"NTP Time Synchronization Is Abnormal."
::= { controller 9 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.8
excessiveFilesExistInADirectory NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Excessive Files Exist In A Directory."
::= { controller 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.12
processMemoryUsageIsTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Process Memory Usage Is Too High."
::= { controller 12 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.7
directoryIsOversized NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A Directory Is Oversized."
::= { controller 7 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.92
openedFilesNumAboutToExceedLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Opened Files On A Controller Is About To Exceed The Upper Limit."
::= { controller 92 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.94
remainAvailableMemoryTooLow NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remaining Available Memory Is Too Low."
::= { controller 94 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.13
cpuUsageTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"CPU Usage Is Too High."
::= { controller 13 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.14
memoryUsageTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Memory Usage Is Too High."
::= { controller 14 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.100
firmwareVersionIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Firmware Version Of The Backup Power Module Of The Controller Incompatible With The Storage Array Software."
::= { controller 100 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.10
controllerNetStackIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Network Protocol Stack Of A Controller Is Abnormal."
::= { controller 10 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.99
bbuTempHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Temperature Of The Backup Power Module Of The Controller Exceeds The Upper Limit ."
::= { controller 99 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.93
cpuUsageIsTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"CPU Usage Is Too High."
::= { controller 93 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.21
monitorControllersFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Monitor Controllers Enclosure."
::= { controller 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.96
memoryCapacityIsNotSupported NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Incorrect Controller Memory Capacity."
::= { controller 96 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208
expandboardmodule OBJECT IDENTIFIER ::= { storage 208 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.24
expansionModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Module Is Faulty."
::= { expandboardmodule 24 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.23
syncExpansionFirmwareFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Synchronize The Firmware Version Of An Expansion Module."
::= { expandboardmodule 23 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.57
sasExpansionModuleIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Shared SAS Expansion Module Firmware Is Incompatible With Storage Array Software."
::= { expandboardmodule 57 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.41
expansionModuleIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Module Firmware Is Incompatible With Storage Array Software."
::= { expandboardmodule 41 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.22
expansionCableLinkError NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Module Is Incorrectly Cabled."
::= { expandboardmodule 22 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.1
expansionModuleIsRemoved NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Module Is Removed."
::= { expandboardmodule 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.2
expansionModuleIsNotInserted NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Module Is Not Inserted."
::= { expandboardmodule 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.3
expansionModuleFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Expansion Module Is Faulty."
::= { expandboardmodule 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.20
abnormalCommBetweenExpModules NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Abnormal Communication Between Expansion Modules."
::= { expandboardmodule 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209
interfacemodule OBJECT IDENTIFIER ::= { storage 209 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.5
interfaceModuleIsRemoved NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Interface Module Is Removed."
::= { interfacemodule 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.8
interfaceModuleIsUnrecognizable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Interface Module Is Unrecognizable."
::= { interfacemodule 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.10
incorrectRemovalInterfaceModule NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Incorrect Removal Of Interface Module."
::= { interfacemodule 10 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.9
interfaceModuleTempExceedsLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Interface Module Temperature Exceeds The Upper Limit."
::= { interfacemodule 9 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.30
monitorInterfaceModuleFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Interface Module Cannot Be Monitored."
::= { interfacemodule 30 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.66
failedToMonitorTheInternalLink NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Monitor The Internal Link Of An Interface Module."
::= { interfacemodule 66 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.62
internalLinkofIntfModIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Internal Link Of Interface Module Is Faulty."
::= { interfacemodule 62 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.65
faultyInterfaceModuleComponent NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Faulty Interface Module Component."
::= { interfacemodule 65 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.50
managementModuleIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Management Module Firmware Is Incompatible With Storage Array Software."
::= { interfacemodule 50 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.35
communicationIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Communication Link Fault Among Management Modules."
::= { interfacemodule 35 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.40
interfaceModuleIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Interface Module Firmware Is Incompatible With Storage Array Software."
::= { interfacemodule 40 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.60
managementModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Management Module Is Faulty."
::= { interfacemodule 60 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.59
managementModuleIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Management Module Is Abnormal."
::= { interfacemodule 59 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.56
pcieChannelIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"PCIe Channel Between An Interface Module And A Controller Is Abnormal."
::= { interfacemodule 56 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.19
someStatusMonitoringFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Some Statuses Of A Management Module Cannot Be Monitored."
::= { interfacemodule 19 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.61
interfaceModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Interface Module Is Faulty."
::= { interfacemodule 61 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.17
pcieChannelIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The PCIe Channel Between An Interface Module And A Controller Is Abnormal."
::= { interfacemodule 17 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.18
slotDoesNotMatchInterfaceModule NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Interface Module Is Not Supported Or The Interface Module Is Inserted Into An Incorrect Slot ."
::= { interfacemodule 18 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210
backuppowermodule OBJECT IDENTIFIER ::= { storage 210 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.28
bbuModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"BBU Module Is Faulty."
::= { backuppowermodule 28 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.29
bbuModuleLifeIsOvertime NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"BBU Module Reaches Its Expiration Date Or Is Aging."
::= { backuppowermodule 29 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.30
bbuModuleIsAboutToExpire NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"BBU Module Is About To Expire."
::= { backuppowermodule 30 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.5
bbuModuleTempExceedsLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"BBU Module Temperature Exceeds The Upper Limit."
::= { backuppowermodule 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.20
failedToMonitorABBUModule NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"BBU Module Cannot Be Monitored."
::= { backuppowermodule 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.39
bbuFirmwareIncompatible NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"BBU Firmware Is Incompatible With Storage Array Software."
::= { backuppowermodule 39 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.4
bbuModuleIsRemoved NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"BBU Module Is Removed."
::= { backuppowermodule 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.25
bbuModuleTypeDoesNotComply NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The BBU Type Does Not Comply With The System Specification."
::= { backuppowermodule 25 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.27
bbuModuleTempIsBelowLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"BBU Module Temperature Is Below The Lower Limit."
::= { backuppowermodule 27 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.211
fanmodule OBJECT IDENTIFIER ::= { storage 211 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.211.3
fanModuleIsRemoved NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Fan Module Is Removed."
::= { fanmodule 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.211.21
fanModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Fan Module Is Faulty."
::= { fanmodule 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216
storagepool OBJECT IDENTIFIER ::= { storage 216 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.291
ckgMetadataHasFaults NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"CKG Metadata Of The Storage Pool Has Faults."
::= { storagepool 291 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.86
extentMetadataOfVolumeHasFaults NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Extent Metadata Of A Volume Has Faults."
::= { storagepool 86 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.289
usedCapacityReachAlarmThreshold NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Used Protection Capacity Reaches The Alarm Threshold."
::= { storagepool 289 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.43
availableSpaceInsufficient NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Available Space In The Storage Pool Is Insufficient."
::= { storagepool 43 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.290
smartTierUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SmartTier Unavailable."
::= { storagepool 290 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.44
availableSpaceUsedUp NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"No Available Space In The Storage Pool."
::= { storagepool 44 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.288
storagePoolCapacityShouldUseUp NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Storage Pool Capacity Is About To Be Used Up."
::= { storagepool 288 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.281
storagePoolCapacityNotEnough NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Storage Pool Remaining Capacity Is Insufficient."
::= { storagepool 281 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.218
smartcachepool OBJECT IDENTIFIER ::= { storage 218 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.218.2
smartCacheDiskIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A Member Disk Of A SmartCache Pool Gets A Fault."
::= { smartcachepool 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.219
luncopy OBJECT IDENTIFIER ::= { storage 219 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.219.2
almCpyFullCopyFail NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Full LUN Copy Is Faulty."
::= { luncopy 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.220
clone OBJECT IDENTIFIER ::= { storage 220 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.220.1
almCLnPairInterrupt NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Clone Pair Is Abnormally Interrupted."
::= { clone 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.220.3
almClnPairFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Clone Pair Is Unavailable."
::= { clone 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.221
consistentgroup OBJECT IDENTIFIER ::= { storage 221 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.221.4
remoteReplicationCGAutoSplit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remote Replication Consistency Group Is Automatically Split."
::= { consistentgroup 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.221.2
remoteReplicationCGIsUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remote Replication Consistency Group Is Unavailable."
::= { consistentgroup 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.221.1
remoteReplicationCGIsInterrupted NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remote Replication Consistency Group Is Disconnected."
::= { consistentgroup 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.224
remotedevice OBJECT IDENTIFIER ::= { storage 224 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.224.20
noBackupLinkForRep NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"No Backup Links Available."
::= { remotedevice 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.224.1
repLinkDown NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Replication Link Is Down."
::= { remotedevice 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232
pciedataswitch OBJECT IDENTIFIER ::= { storage 232 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.24
switchFanModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Fan Module Is Faulty."
::= { pciedataswitch 24 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.1
powerSupplyOfSwitchIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Power Supply Of The Switch Is Faulty."
::= { pciedataswitch 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.26
switchPowerInputIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Input To The Switch Power Module Is Abnormal."
::= { pciedataswitch 26 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.25
switchFanModuleIsRemoved NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Fan Module Is Removed."
::= { pciedataswitch 25 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.36
negoRateSmallerThanTheMax NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Port Negotiated Rate Is Smaller Than The Allowed Maximum Rate."
::= { pciedataswitch 36 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.34
switchPortOpticalModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Port Optical Module Is Faulty."
::= { pciedataswitch 34 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.43
switchFailToMonitorPowModules NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Failed To Monitor Power Modules."
::= { pciedataswitch 43 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.20
switchIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Is Faulty."
::= { pciedataswitch 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.22
switchTempExceedsLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Temperature Exceeds The Upper Limit."
::= { pciedataswitch 22 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.30
switchManageNetworkPortIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Management Network Port Is Faulty."
::= { pciedataswitch 30 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.27
switchPowerModuleIsRemoved NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Power Module Is Removed."
::= { pciedataswitch 27 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.21
switchFailedToBeMonitored NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Failed To Be Monitored."
::= { pciedataswitch 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.23
switchTempIsBelowLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Temperature Is Below The Lower Limit."
::= { pciedataswitch 23 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.31
switchPortIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Port Is Faulty."
::= { pciedataswitch 31 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.38
linkToASwitchPortIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Link To A Switch Port Is Abnormal."
::= { pciedataswitch 38 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.40
dswEthPortIsDown NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Management Network Port Is Disconnected."
::= { pciedataswitch 40 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.39
failedToMonitorSwitchOpModule NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Switch Optical Module Cannot Be Monitored."
::= { pciedataswitch 39 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.42
switchFailToMonitorFanModules NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Switch Failed To Monitor Fan Modules."
::= { pciedataswitch 42 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234
sfpopticaltransceiver OBJECT IDENTIFIER ::= { storage 234 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.3
portOpticalModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Port Optical Module Is Faulty."
::= { sfpopticaltransceiver 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.5
opticalModuleRateIsInconsistent NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Optical Module Rate Is Inconsistent With That Of Its Port."
::= { sfpopticaltransceiver 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.24
failedToMonitorOpOrEleModule NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The System Failed To Monitor An Optical Or Electrical Module."
::= { sfpopticaltransceiver 24 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.20
portLinkIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Abnormal Port Link."
::= { sfpopticaltransceiver 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.21
failedToMonitorAnOpticalModule NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Optical Module Cannot Be Monitored."
::= { sfpopticaltransceiver 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.244
license OBJECT IDENTIFIER ::= { storage 244 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.244.1
licenseIsAboutToExpire NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"License Is About To Expire."
::= { license 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.244.2
licenseHasExpired NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"License Has Expired."
::= { license 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.244.6
licenseIsInvalidWithStartDate NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Invalid License."
::= { license 6 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.253
lunmigrationtask OBJECT IDENTIFIER ::= { storage 253 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.253.8
almSmartMigrationErr NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SmartMigration Is Faulty."
::= { lunmigrationtask 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263
replicationpair OBJECT IDENTIFIER ::= { storage 263 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.58
autoStartSynRemoteRepFails NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remote Replication Failed To Synchronize Data Automatically."
::= { replicationpair 58 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.56
remoteReplicationIsInterrupted NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remote Replication Is Interrupted."
::= { replicationpair 56 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.57
remoteReplicationIsInvalid NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remote Replication Is Unavailable."
::= { replicationpair 57 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.5
autoStartSynRemoteRepCGFails NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remote Replication Consistency Group Failed To Synchronize Data Automatically."
::= { replicationpair 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.311
remoteReplicationAutomaticSplit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Remote Replication Is Automatically Split."
::= { replicationpair 311 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.274
fsRemoteReplicationPairInvalid NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A Remote Replication Is Unavailable."
::= { replicationpair 274 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.275
fsRemoteReplicationPairFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A Remote Replication Is Abnormally Interrupted."
::= { replicationpair 275 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.304
fsRemoteReplicationAutoSyncFail NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A Remote Replication Fails To Synchronize Data Automatically."
::= { replicationpair 304 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.22
failedRecoverRmReplication NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Recover The LUN Remote Replication Service At The Array End."
::= { replicationpair 22 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.21
addRemoteReplicationToCGFails NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Add Remote Replication To A Consistent Group."
::= { replicationpair 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266
diskdomain OBJECT IDENTIFIER ::= { storage 266 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.83
diskDomainEnterSecureVideoState NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Domain Entering The SecureVideo State."
::= { diskdomain 83 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.3
diskDomainIsOffline NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Domain Is Offline."
::= { diskdomain 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.2
diskDomainFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Domain Is Faulty."
::= { diskdomain 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.1
diskDomainDegradation NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Disk Domain Is Degraded."
::= { diskdomain 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.84
backgroudTaskFailedToStart NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Background Task Of A Disk Domain Failed To Start."
::= { diskdomain 84 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.6
differentDiskType NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Inconsistent Disk Domain Disk Types."
::= { diskdomain 6 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.5
hotSpareCapacityInsufficient NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Hot Spare Capacity Of The Disk Domain Is Insufficient."
::= { diskdomain 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.8
diskIsRemovedFromDiskDomain NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A Disk Is Removed From A Disk Domain."
::= { diskdomain 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.32
newDiskCapacityInsufficieny NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A New Disk Fails To Be Added To The Disk Domain."
::= { diskdomain 32 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.268
cachepartition OBJECT IDENTIFIER ::= { storage 268 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.268.11
controllerWriteCacheDisabled NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Controller Write Cache Is Disabled."
::= { cachepartition 11 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.268.12
cachePartitionWriteCacheDisabled NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Write Cache For A Cache Partition Is Disabled."
::= { cachepartition 12 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.269
qos OBJECT IDENTIFIER ::= { storage 269 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.269.67
failReachSmartQoSObjective NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Reach The Control Objective Of SmartQoS."
::= { qos 67 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.273
smartcachepartition OBJECT IDENTIFIER ::= { storage 273 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.273.1
smartcacheIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SmartCache Function Is Unavailable."
::= { smartcachepartition 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.285
anti-virus OBJECT IDENTIFIER ::= { storage 285 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.285.71
antivirusServiceIsNotAvailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Antivirus Service Is Not Available."
::= { anti-virus 71 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.285.68
antivirusServerIsFault NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Antivirus Server Is Fault."
::= { anti-virus 68 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293
hypervault OBJECT IDENTIFIER ::= { storage 293 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.0
hyperVaultJobCongestion NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A HyperVault Job Is Congested."
::= { hypervault 0 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.4
hyperVaultScheduledTaskFailure NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperVault Fails To Be Started As Scheduled."
::= { hypervault 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.13
hyperVaultCopiesReachUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of HyperVault Copies Reaches The Upper Limit ."
::= { hypervault 13 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.2
hyperVaultLinkIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Link To A Remote Device Is Down."
::= { hypervault 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.3
hyperVaultFileSystemFaults NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Owning File System Of A HyperVault Is Faulty."
::= { hypervault 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.12
hyperVaultPairInvalid NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Invalid HyperVault Pair."
::= { hypervault 12 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.14
hyperVaultInterruption NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperVault Is Interrupted ."
::= { hypervault 14 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.306
assistantCoolingUnit OBJECT IDENTIFIER ::= { storage 306 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.306.4
assistCoolingUnitMonitorFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The System Failed To Monitor Assistant Cooling Unit."
::= { assistantCoolingUnit 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.306.1
assistantCoolingUnitNotPresent NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Assistant Cooling Unit Not Present."
::= { assistantCoolingUnit 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.306.5
coolingUnitIsUnrecognizable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Assistant Cooling Unit Is Unrecognizable."
::= { assistantCoolingUnit 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582
svp OBJECT IDENTIFIER ::= { storage 582 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.16
svpCpuUsageIsTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The SVP CPU Usage Is Too High."
::= { svp 16 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.6
svpFanModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP Fan Module Is Faulty."
::= { svp 6 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.2
svpEnclosureTemperatureIsHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP Enclosure Temperature Is Too High."
::= { svp 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.1
svpCPUTemperatureIsHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP CPU Temperature Is Too High."
::= { svp 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.0
svpMainboardIsFaultyWithErrCode NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP Mainboard Is Faulty."
::= { svp 0 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.10
svpLUNDegrades NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP LUN Degrades."
::= { svp 10 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.5
svpPowerModuleIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP Power Module Is Faulty."
::= { svp 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.4
svpPowerModuleAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP Power Module Input Is Abnormal."
::= { svp 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.20
manageStorageEquipmentFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Manage The Storage Equipment."
::= { svp 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.11
manageSVPFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Manage The SVP."
::= { svp 11 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.18
svpProcessCpuUsageIsTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The CPU Usage Of An SVP Process Is Too High."
::= { svp 18 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.17
svpNtpSynchronizationIsAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"SVP NTP Time Synchronization Is Abnormal."
::= { svp 17 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.19
svpProcessMemoryUsageIsTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Memory Usage Of An SVP Process Is Too High."
::= { svp 19 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.15
svpDirectoryExcessiveFilesExist NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Excessive Files Exist In An SVP Directory."
::= { svp 15 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.14
svpDirectoryIsOversized NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"An SVP Directory Is Oversized."
::= { svp 14 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.13
svpMemoryUsageIsTooHigh NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The SVP Memory Usage Is Too High."
::= { svp 13 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.583
lunmirror OBJECT IDENTIFIER ::= { storage 583 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.583.16
almLunMirrorCopyErr NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Mirror Copy Is Abnormally Interrupted."
::= { lunmirror 16 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.583.17
almLunMirrorCopyUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Mirror Copy Is Unavailable."
::= { lunmirror 17 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.815
blockdevice OBJECT IDENTIFIER ::= { storage 815 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.815.3
blockDeviceIsFaulty NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Block Device Is Faulty."
::= { blockdevice 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.818
devicemanager OBJECT IDENTIFIER ::= { storage 818 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.818.2
caCertificateIsExpiring NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Certificate Of The DeviceManager Server Is Expiring."
::= { devicemanager 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.818.3
caCertificateHasExpired NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Certificate Of The DeviceManager Server Has Expired."
::= { devicemanager 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822
systemreporter OBJECT IDENTIFIER ::= { storage 822 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.29
operationLogsExceedsUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Number Of Operation Logs Exceeds The Upper Limit."
::= { systemreporter 29 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.30
sshServiceUntrust NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The SSH Service Is Untrusted."
::= { systemreporter 30 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.16
majorUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Usage Exceeded The Threshold."
::= { systemreporter 16 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.8
criticalAvgCpuUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average CPU Usage Exceeded The Threshold."
::= { systemreporter 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.7
warnTimeSinceLastSyncThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Time Since Last Synchronization Exceeded The Threshold."
::= { systemreporter 7 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.11
criticalAvgIORespThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average I/O Response Time Exceeded The Threshold."
::= { systemreporter 11 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.10
criticalServiceTimeThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Service Time Exceeded The Threshold."
::= { systemreporter 10 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.1
warnAvgCpuUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average CPU Usage Exceeded The Threshold."
::= { systemreporter 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.19
majorMaxIORespTimeThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Maximum I/O Response Time Exceeded The Threshold."
::= { systemreporter 19 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.18
majorAvgIORespTimeThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average I/O Response Time Exceeded The Threshold."
::= { systemreporter 18 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.21
majorTimeSinceSyncThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Time Since Last Synchronization Exceeded The Threshold."
::= { systemreporter 21 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.6
warnAvgCacheUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average Cache Usage Exceeded The Threshold."
::= { systemreporter 6 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.4
warnAvgIORespTimeThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average I/O Response Time Exceeded The Threshold."
::= { systemreporter 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.15
majorAvgCpuUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average CPU Usage Exceeded The Threshold."
::= { systemreporter 15 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.14
criticalTimeSinceSyncThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Time Since Last Synchronization Exceeded The Threshold."
::= { systemreporter 14 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.9
criticalUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Usage Exceeded The Threshold."
::= { systemreporter 9 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.17
majorServiceTimeThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Service Time Exceeded The Threshold."
::= { systemreporter 17 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.13
criticalAvgCacheUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average Cache Usage Exceeded The Threshold."
::= { systemreporter 13 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.3
warnServiceTimeThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Service Time Exceeded The Threshold."
::= { systemreporter 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.12
criticalMaxIORespThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Maximum I/O Response Time Exceeded The Threshold."
::= { systemreporter 12 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.2
warnUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Usage Exceeded The Threshold."
::= { systemreporter 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.5
warnMaxIORespTimeThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Maximum I/O Response Time Exceeded The Threshold."
::= { systemreporter 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.20
majorAvgCacheUsageThreshAlarm NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Average Cache Usage Exceeded The Threshold."
::= { systemreporter 20 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.823
serverAgent OBJECT IDENTIFIER ::= { storage 823 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.823.12
serverLinkIsDown NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Server Link Is Down."
::= { serverAgent 12 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361
hypermetro OBJECT IDENTIFIER ::= { storage 15361 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.3
hyperMetroIsInvalid NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Invalid HyperMetro Pair."
::= { hypermetro 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.1
hyperMetroIsUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperMetro Is Unavailable."
::= { hypermetro 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.4
hyperMetroIsInterrupted NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperMetro Pair Interrupted Unexpectedly."
::= { hypermetro 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.2
hostIncorrectAccessForPair NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Host Has An Incorrect Access Permission."
::= { hypermetro 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.0
hyperMetroIsDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperMetro Is Disconnected."
::= { hypermetro 0 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.7
hyperMetroConfigInterrupt NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperMetro Pair Configuration Is Abnormally Interrupted."
::= { hypermetro 7 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.8
hyperMetroNasPairIsIsolated NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"One Storage Array Of A HyperMetro Pair Is Isolated ."
::= { hypermetro 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15362
hypermetrodomain OBJECT IDENTIFIER ::= { storage 15362 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15362.0
hyperMetroDomainIsUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperMetro Domain Is Unavailable."
::= { hypermetrodomain 0 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15363
quorumserver OBJECT IDENTIFIER ::= { storage 15363 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15363.0
quorumServerDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Arbitration Server Is Disconnected From Storage Arrays."
::= { quorumserver 0 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15364
hypermetroconsistencygroup OBJECT IDENTIFIER ::= { storage 15364 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15364.3
hostIncorrectAccessForGroup NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Host Has An Incorrect Access Permission."
::= { hypermetroconsistencygroup 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15364.2
hyperMetroGroupIsUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperMetro Consistency Group Is Unavailable."
::= { hypermetroconsistencygroup 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15364.1
hyperMetroGroupIsDisconnected NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperMetro Consistency Group Is Disconnected."
::= { hypermetroconsistencygroup 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15365
quorumserverlink OBJECT IDENTIFIER ::= { storage 15365 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15365.0
quorumLinkDown NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Quorum Server Link Is Down."
::= { quorumserverlink 0 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446
resourceuser OBJECT IDENTIFIER ::= { storage 16446 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446.1
pwdOfResUserIsAboutToExpire NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Password Of The Resource User Is About To Expire."
::= { resourceuser 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446.4
resUserHasBeenLocked NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Resource User Has Been Locked."
::= { resourceuser 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446.2
pwdOfResUserHasExpired NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Password Of The Resource User Has Expired."
::= { resourceuser 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446.3
resUserIsAboutToBeLocked NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Resource User Is About To Be Locked."
::= { resourceuser 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16450
httpservice OBJECT IDENTIFIER ::= { storage 16450 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16450.1
startHttpServiceFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Start The HTTP Service Failed."
::= { httpservice 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16451
ftpservice OBJECT IDENTIFIER ::= { storage 16451 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16451.1
startFtpServiceFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Start The FTP Service Failed."
::= { ftpservice 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453
cifsservice OBJECT IDENTIFIER ::= { storage 16453 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453.44
domainDNSServiceUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Domain DNS Service Is Unavailable."
::= { cifsservice 44 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453.43
adDomainServiceUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"AD Domain Service Is Unavailable."
::= { cifsservice 43 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453.1
auditLogFileSystemAbnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Audit Log File System Is Abnormal."
::= { cifsservice 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453.2
auditFSFreeCapacityNotEnough NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Available Capacity Of The Audit Log File System Is Insufficient."
::= { cifsservice 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16458
filesystemquota OBJECT IDENTIFIER ::= { storage 16458 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16458.14
fsUsedQuotaExceedsDirQuota NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Used Resource Of A File System Quota Exceeds The Soft Quota."
::= { filesystemquota 14 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16458.15
fsUsedQuotaExceedsUsrGrpQuota NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Used Resource Of A File System Quota Exceeds The Soft Quota."
::= { filesystemquota 15 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16458.13
fsUsedExceedUserOrGroupSoftQuota NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Used Resource Of A File System Quota Exceeds The Soft Quota."
::= { filesystemquota 13 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350
virtualmachine OBJECT IDENTIFIER ::= { storage 57350 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.104
remainSpaceOfVMfsIsLower NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Remain Space Of The Virtual Machine File System Is Lower Than Threshold Percentage."
::= { virtualmachine 104 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.98
ioErrorsOccurOnVirtualMachine NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Some Read/Write Errors Occur On A Virtual Machine."
::= { virtualmachine 98 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.118
vmFailsShutDown NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"VM Fails To Be Correctly Shut Down Within The Specified Time During Array Power-Off."
::= { virtualmachine 118 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.1
incompleteVirtualMachineCreation NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Incomplete Virtual Machine Creation."
::= { virtualmachine 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.100
errorsOccurredOnHypervisor NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Errors Occurred On Hypervisor When Controlling Virtual Machine."
::= { virtualmachine 100 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.97
virtualMachineIsSuspended NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Virtual Machine Is Suspended."
::= { virtualmachine 97 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.89
virtualMachineCrashes NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Virtual Machine Crashes."
::= { virtualmachine 89 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.114
failedToRestoreVirtualMachine NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Restore A Virtual Machine."
::= { virtualmachine 114 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.103
initVMfileSystemFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Initiate The File System Of A Virtual Machine."
::= { virtualmachine 103 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.105
fileSystemOfVMabnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"The Virtual Machine File System Is Abnormal."
::= { virtualmachine 105 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.116
serviceOfVMabnormal NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"VM Service Is Abnormal."
::= { virtualmachine 116 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452
nfsservice OBJECT IDENTIFIER ::= { storage 16452 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452.27
obtainLDAPCertFileFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Obtain The LDAP Certificate File."
::= { nfsservice 27 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452.25
ldapServiceUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"LDAP Service Is Unavailable."
::= { nfsservice 25 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452.24
getLDAPCertificateFileFailed NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Failed To Get LDAP Certificate File And Restart The NFS Service."
::= { nfsservice 24 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452.26
nisServiceUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"NIS Service Is Unavailable."
::= { nfsservice 26 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386
protocolcluster OBJECT IDENTIFIER ::= { storage 16386 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.26
cloneNFSShareReachLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"During File System Clone, The Number Of Copied NFS Share Reaches The Limit."
::= { protocolcluster 26 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.27
cloneNFSPermissionReachLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"During File System Clone, The Number Of Copied NFS Share Permissions Reaches The Limit."
::= { protocolcluster 27 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.2
servicePortConflict NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"A Service Port Conflicts."
::= { protocolcluster 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.7
phRecordReachUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of File Information Items To Be Backed Up Reaches The Upper Limit."
::= { protocolcluster 7 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.9
smb1ShareNumReachUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Share Connections For SMB One Reaches The Upper Limit."
::= { protocolcluster 9 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.8
smb2ShareNumReachUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of Share Connections For SMB Two Reaches The Upper Limit."
::= { protocolcluster 8 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.10
fileLockNumReachUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of File Locks For NAS Reaches The Upper Limit."
::= { protocolcluster 10 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.5
clientConnectionReachUpperLimit NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Number Of NAS Client Connections Of A Controller Reaches The Upper Limit."
::= { protocolcluster 5 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480
certificateManagement OBJECT IDENTIFIER ::= { storage 20480 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480.2
certificateWillExpireWithTime NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Certificate Is About To Expire."
::= { certificateManagement 2 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480.1
certificateExpiredWithDeadline NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Certificate Has Expired."
::= { certificateManagement 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480.4
tenantCertificateWillExpire NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Certificate Is About To Expire."
::= { certificateManagement 4 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480.3
tenantCertificateHasExpired NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Certificate Has Expired."
::= { certificateManagement 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15366
hyperMetroVstorePair OBJECT IDENTIFIER ::= { storage 15366 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15366.1
hostIncorrectAccessForVstorePair NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Hosts Access Permissions For A HyperMetro VStore Pair Are Abnormal."
::= { hyperMetroVstorePair 1 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15366.3
hyperMetroVstoreConfigInterrupt NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"HyperMetro VStore Pair Configuration Is Abnormally Interrupted."
::= { hyperMetroVstorePair 3 }
-- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15366.2
vstorePairIsUnavailable NOTIFICATION-TYPE
OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType,
hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID,
hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo }
STATUS current
DESCRIPTION
"Invalid HyperMetro VStore Pair."
::= { hyperMetroVstorePair 2 }
-- 1.6.1
-- 1.6.1
isoGroups OBJECT IDENTIFIER ::= { isoConformance 1 }
-- 1.6.1.1
-- 1.6.1.1
currentNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { ethFCoEPortIsDisconnected, portIsWorkingInHalfDuplexMode, expPortHasTooManyBitErrors, hostPortHasTooManyBitErrors, pciePortIsPartiallyDamaged, pciePortIsDisconnected, expansionPortPartiallyDamaged, expansionPortIsDisconnected, rateIsSmallerThanAllowedMaximum, portNegotiatedRateNotToMaximum, hostPortIsDisconnected, manageNetworkPortIsDisconnected, expansionPortIsolated, managementNetworkPortIsFaulty, pciePortIsFaulty, hostPortIsFaulty, expansionPortIsFaulty, numberOfDisksExceedsUpperLimit, mixtureOfSATAAndNonSATADisks, diskIsIsolated, slowDiskResponse, authenticationOfSEDAccessFails, cofferDiskIsFaulty, cofferDiskFault, diskInEngineMonitoringFailed, diskMonitoringFailed, diskModelIsIncompatible, diskInSingleLinkState, diskIsAboutToFail, cofferDiskModelIsIncompatible, diskTemperatureExceedsUpperLimit, cofferDiskInInccorrectSlot, diskIsRejectedBySystem, cofferDisksNotFound, authenticationOfSEDKeyFails, diskHardwareIsFaulty,
diskIsUnrecognizable, svpDiskIsFaulty, svpDiskIsNotInserted, externalLunTypeChanged, lunStartBgrTaskFailed, localArrayRegPathToHeteroFailed, theLUNHasMediumError, theLUNLBAHasWarningMediumError, theLUNLBAHasCriticalMediumError, snapshotLUNIsFault, externalLUNFault, externalLUNToOnlyOneController, remoteLinkExceedUpperLimit, remoteArrayExceedUpperLimit, incompatibleArrayConnected, theLUNIsFault, iscsiLinkFaulty, fcLinkFaulty, iscsiLinkDisconnected, fcLinkDisconnected, theLUNIsFault, snapshotLUNIsFault, noRedundantConnectionToHost, aLinkToHostIsDown, ultrapathIncompatibleWithStorage, powerModuleIsFaulty, powerModuleInputIsAbnormal, powerModulesTypesDifferent, diskEnclHasNoRePowerModule, powerModuleIsIncompatible, failedToMonitorAPowerModule, powerModuleIsRemoved, powerModuleFaulty, powerModuleHasNoInput, powerModuleTempExceedsLimit, snapshotStopAbnormally, snapshotUnavailable, failedToDisableTheSnapshot, fsObjectIsIsolated,
fsRemainCapacityIsInsufficient, fileSystemExistMediumError, fileOrDirExistMediumError, openedFilesNumAboutToExceedThres, filesNumAboutToExceedThreshold, filesNumExceedLimit, openedFilesNumExceedLimit, filesNumAboutToExceedLimit, dirFilesNumAboutToExceedLimit, filesNumReachedOrExceededLimit, dirFilesNumExceededLimit, openedFilesNumExceededLimit, subFilesNumToExceedLimit, subFilesNumAboutToExceedLimit, fileSystemMetadataIsDamaged, fileOrDirDamagedInFs, fileSystemIsFaulty, writeProtectionIsEnabledForFS, eventAmountReachUpLimit, controllerWriteCacheIsDisabled, dnsIsUnavailable, ipaddrConflict, onlyOneClusterLinkIsAvailable, systemEnterSafeMode, userInfoNeedReview, passwdOfUserHasExpired, passwdOfUserIsAboutToExpire, passwdOfUserHasExpired, passwdOfUserIsAboutToExpire, enclosureIsFaulty, failedToMonitorTheRearPanel, highDensityAreMixConnected, numOfEnclOnExpPortExceedsLimit, failedToIdentifyEnclosure, enclosureIsUnrecognizable,
enclosureCablingIsIncorrect, faultsOccurredOnEnclosure, diskEnclTempExceedsUpperLimit, diskEnclTempIsBelowLimit, ctrlEnclTempExceedsUpperLimit, ctrlEnclTempIsFarBeyondUpLimit, diskEnclTempIsFarBeyondUpLimit, enclSpeedSmallerThanLoopSpeed, anUnsupportedExpEnclConnected, diskEnclosureIsSingleLink, failedToMonitorADiskEnclosure, monitorControllerFailed, abnormalCommunicateBetweenCtrls, controllerCannotBeMonitored, controllerServicesAbnormal, controllerIsFaulty, bbuIsFault, ctrlAndMgtCommunicateLinkFault, controllerIsFaulty, controllerIsOffline, portIsIncorrectlyConnected, controllerIsRemoved, theCoinBatteryIsFaulty, ftpServiceIsAbnormal, processCpuUsageIsTooHigh, sshServiceIsAbnormal, bbuIsFault, ntpSynchronizationIsAbnormal, excessiveFilesExistInADirectory, processMemoryUsageIsTooHigh, directoryIsOversized, openedFilesNumAboutToExceedLimit, remainAvailableMemoryTooLow, cpuUsageTooHigh, memoryUsageTooHigh, firmwareVersionIncompatible,
controllerNetStackIsAbnormal, bbuTempHigh, cpuUsageIsTooHigh, monitorControllersFailed, memoryCapacityIsNotSupported, expansionModuleIsFaulty, syncExpansionFirmwareFailed, sasExpansionModuleIncompatible, expansionModuleIncompatible, expansionCableLinkError, expansionModuleIsRemoved, expansionModuleIsNotInserted, expansionModuleFaulty, abnormalCommBetweenExpModules, interfaceModuleIsRemoved, interfaceModuleIsUnrecognizable, incorrectRemovalInterfaceModule, interfaceModuleTempExceedsLimit, monitorInterfaceModuleFailed, failedToMonitorTheInternalLink, internalLinkofIntfModIsFaulty, faultyInterfaceModuleComponent, managementModuleIncompatible, communicationIsFaulty, interfaceModuleIncompatible, managementModuleIsFaulty, managementModuleIsAbnormal, pcieChannelIsFaulty, someStatusMonitoringFailed, interfaceModuleIsFaulty, pcieChannelIsAbnormal, slotDoesNotMatchInterfaceModule, bbuModuleIsFaulty, bbuModuleLifeIsOvertime,
bbuModuleIsAboutToExpire, bbuModuleTempExceedsLimit, failedToMonitorABBUModule, bbuFirmwareIncompatible, bbuModuleIsRemoved, bbuModuleTypeDoesNotComply, bbuModuleTempIsBelowLimit, fanModuleIsRemoved, fanModuleIsFaulty, ckgMetadataHasFaults, extentMetadataOfVolumeHasFaults, usedCapacityReachAlarmThreshold, availableSpaceInsufficient, smartTierUnavailable, availableSpaceUsedUp, storagePoolCapacityShouldUseUp, storagePoolCapacityNotEnough, smartCacheDiskIsFaulty, almCpyFullCopyFail, almCLnPairInterrupt, almClnPairFault, remoteReplicationCGAutoSplit, remoteReplicationCGIsUnavailable, remoteReplicationCGIsInterrupted, noBackupLinkForRep, repLinkDown, switchFanModuleIsFaulty, powerSupplyOfSwitchIsFaulty, switchPowerInputIsAbnormal, switchFanModuleIsRemoved, negoRateSmallerThanTheMax, switchPortOpticalModuleIsFaulty, switchFailToMonitorPowModules, switchIsFaulty, switchTempExceedsLimit, switchManageNetworkPortIsFaulty,
switchPowerModuleIsRemoved, switchFailedToBeMonitored, switchTempIsBelowLimit, switchPortIsFaulty, linkToASwitchPortIsAbnormal, dswEthPortIsDown, failedToMonitorSwitchOpModule, switchFailToMonitorFanModules, portOpticalModuleIsFaulty, opticalModuleRateIsInconsistent, failedToMonitorOpOrEleModule, portLinkIsAbnormal, failedToMonitorAnOpticalModule, licenseIsAboutToExpire, licenseHasExpired, licenseIsInvalidWithStartDate, almSmartMigrationErr, autoStartSynRemoteRepFails, remoteReplicationIsInterrupted, remoteReplicationIsInvalid, autoStartSynRemoteRepCGFails, remoteReplicationAutomaticSplit, fsRemoteReplicationPairInvalid, fsRemoteReplicationPairFault, fsRemoteReplicationAutoSyncFail, failedRecoverRmReplication, addRemoteReplicationToCGFails, diskDomainEnterSecureVideoState, diskDomainIsOffline, diskDomainFault, diskDomainDegradation, backgroudTaskFailedToStart, differentDiskType, hotSpareCapacityInsufficient, diskIsRemovedFromDiskDomain,
newDiskCapacityInsufficieny, controllerWriteCacheDisabled, cachePartitionWriteCacheDisabled, failReachSmartQoSObjective, smartcacheIsFaulty, antivirusServiceIsNotAvailable, antivirusServerIsFault, hyperVaultJobCongestion, hyperVaultScheduledTaskFailure, hyperVaultCopiesReachUpperLimit, hyperVaultLinkIsFaulty, hyperVaultFileSystemFaults, hyperVaultPairInvalid, hyperVaultInterruption, assistCoolingUnitMonitorFailed, assistantCoolingUnitNotPresent, coolingUnitIsUnrecognizable, svpCpuUsageIsTooHigh, svpFanModuleIsFaulty, svpEnclosureTemperatureIsHigh, svpCPUTemperatureIsHigh, svpMainboardIsFaultyWithErrCode, svpLUNDegrades, svpPowerModuleIsFaulty, svpPowerModuleAbnormal, manageStorageEquipmentFailed, manageSVPFailed, svpProcessCpuUsageIsTooHigh, svpNtpSynchronizationIsAbnormal, svpProcessMemoryUsageIsTooHigh, svpDirectoryExcessiveFilesExist, svpDirectoryIsOversized, svpMemoryUsageIsTooHigh, almLunMirrorCopyErr, almLunMirrorCopyUnavailable,
blockDeviceIsFaulty, caCertificateIsExpiring, caCertificateHasExpired, operationLogsExceedsUpperLimit, sshServiceUntrust, majorUsageThreshAlarm, criticalAvgCpuUsageThreshAlarm, warnTimeSinceLastSyncThreshAlarm, criticalAvgIORespThreshAlarm, criticalServiceTimeThreshAlarm, warnAvgCpuUsageThreshAlarm, majorMaxIORespTimeThreshAlarm, majorAvgIORespTimeThreshAlarm, majorTimeSinceSyncThreshAlarm, warnAvgCacheUsageThreshAlarm, warnAvgIORespTimeThreshAlarm, majorAvgCpuUsageThreshAlarm, criticalTimeSinceSyncThreshAlarm, criticalUsageThreshAlarm, majorServiceTimeThreshAlarm, criticalAvgCacheUsageThreshAlarm, warnServiceTimeThreshAlarm, criticalMaxIORespThreshAlarm, warnUsageThreshAlarm, warnMaxIORespTimeThreshAlarm, majorAvgCacheUsageThreshAlarm, serverLinkIsDown, hyperMetroIsInvalid, hyperMetroIsUnavailable, hyperMetroIsInterrupted, hostIncorrectAccessForPair, hyperMetroIsDisconnected, hyperMetroConfigInterrupt, hyperMetroNasPairIsIsolated,
hyperMetroDomainIsUnavailable, quorumServerDisconnected, hostIncorrectAccessForGroup, hyperMetroGroupIsUnavailable, hyperMetroGroupIsDisconnected, quorumLinkDown, pwdOfResUserIsAboutToExpire, resUserHasBeenLocked, pwdOfResUserHasExpired, resUserIsAboutToBeLocked, startHttpServiceFailed, startFtpServiceFailed, domainDNSServiceUnavailable, adDomainServiceUnavailable, auditLogFileSystemAbnormal, auditFSFreeCapacityNotEnough, fsUsedQuotaExceedsDirQuota, fsUsedQuotaExceedsUsrGrpQuota, fsUsedExceedUserOrGroupSoftQuota, remainSpaceOfVMfsIsLower, ioErrorsOccurOnVirtualMachine, vmFailsShutDown, incompleteVirtualMachineCreation, errorsOccurredOnHypervisor, virtualMachineIsSuspended, virtualMachineCrashes, failedToRestoreVirtualMachine, initVMfileSystemFailed, fileSystemOfVMabnormal, serviceOfVMabnormal, obtainLDAPCertFileFailed, ldapServiceUnavailable, getLDAPCertificateFileFailed, nisServiceUnavailable, cloneNFSShareReachLimit,
cloneNFSPermissionReachLimit, servicePortConflict, phRecordReachUpperLimit, smb1ShareNumReachUpperLimit, smb2ShareNumReachUpperLimit, fileLockNumReachUpperLimit, clientConnectionReachUpperLimit, certificateWillExpireWithTime, certificateExpiredWithDeadline, tenantCertificateWillExpire, tenantCertificateHasExpired, hostIncorrectAccessForVstorePair, hyperMetroVstoreConfigInterrupt, vstorePairIsUnavailable }
STATUS current
DESCRIPTION
"Enter the description of the created NOTIFICATION-GROUP."
::= { isoGroups 1 }
END
--
-- ISM-HUAWEI-OID-BASED-TRAP-MIB.mib
--