Observium_CE/mibs/force10/DF10-DCB-MIB

1610 lines
56 KiB
Plaintext

-- Dell Networking OS DCB Proprietary MIB Definition
-- This document explains the proprietary MIB implemented
-- for the DCB Features.
-- Data Center Bridging is a flexible framework that defines the
-- capabilities required for switches and end points to be part of a
-- data center network.
-- DCB contains the following capabilities:
-- 1. Priority-based flow control (PFC; IEEE 802.1Qbb)
-- The Priority-based Flow Control (PFC) feature is used for a
-- link level flow control mechanism that can be independently
-- controlled for each priority.
-- 2. Enhanced transmission selection (ETS; IEEE 802.1Qaz)
-- The Enhanced Transmission Selection (ETS) feature provides a
-- common management framework for assignment of bandwidth to
-- traffic classes
-- 3. DCBX is a discovery and capability exchange protocol that is used
-- by devices enabled for Data Center Bridging to exchange
-- configuration information. "
DF10-DCB-MIB DEFINITIONS ::= BEGIN
-- This MIB contains tables used to configure a Dell Networking OS switch
-- for the DCB functionality
--
-- This module will be extended, as needed.
IMPORTS
Unsigned32,
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Counter32,
Integer32
FROM SNMPv2-SMI
InterfaceIndex
FROM IF-MIB
TEXTUAL-CONVENTION,
TruthValue,
MacAddress
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
f10Mgmt
FROM FORCE10-SMI;
dF10Dcb MODULE-IDENTITY
LAST-UPDATED "201204160000Z" -- Apr 16, 2012
ORGANIZATION "Dell Inc."
CONTACT-INFO
"http://www.force10networks.com/support"
DESCRIPTION
"The proprietary extension MIB module for Dell Networking OS DCB and DCBX."
REVISION "201204160000Z" -- Apr 16, 2012
DESCRIPTION
"1.Modified Access permission of following objects to read-only
dF10ETSAdminMode,dF10PFCAdminMode,dF10DCBXAdminStatus,
dF10DcbPfcMinThreshold,dF10DcbPfcMaxThreshold,
dF10DcbETSAdminStatus,dF10DcbPFCAdminStatus,
dF10ETSSystemControl,dF10ETSModuleStatus,
dF10PFCSystemControl,dF10PFCModuleStatus,
dF10ETSGlobalEnableTrap,dF10PFCGlobalEnableTrap,
as enabling DCB on interface has been changed to policy based options.
2.Removed 'auto' from DcbAdminMode as ets/pfc mode supported are on/off.
3.Removed dF10DcbRowStatus,dF10ETSRowStatus,dF10PFCRowStatus objects."
REVISION "201111240000Z" -- Nov 24, 2011
DESCRIPTION
"Added interoperablity support - Modified MIB to reflect
Configuration Exchange and Auto detection of version.
1. Modified DcbState Textual Convention to include internally
propagated information from Config Source.
2. Modified DcbStateMachineType - for legacy DCBX versions
like CIN, CEE we only have a feature state machine.
3. Added textual convention DcbxPortRole for various port
roles supported for Configuration Exchange.
4. Added textual convention DcbxVersion for the different
versions of DCBX - CIN/ CEE /IEEEv2.4.
5. Added a new table dF10DCBXPortStatusTable for the
statistics and configuration exchange and version specific
details.
6. Added Compliance and Conformance information."
REVISION "201009250000Z" -- Aug 25 2010
DESCRIPTION "Initial version of DCBX mib."
::= { f10Mgmt 15}
EnabledStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A simple status value for the object."
SYNTAX INTEGER { enabled(1), disabled(2) }
DcbAdminMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"'on(1)', In this mode, the configurations,
either from this system or the remote system will take
effect based on DCBX negotiations.
'off(2)', In this mode, all the operational(local) parameters
for the feature will be same as Admin Configuration Parameters.
But Operational(local) parameters do not have any impact in the system."
SYNTAX INTEGER { on(1), off(2)}
DcbState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The state of the DCBX state machine.
off '(0)', In this state all Operational(local) parameters
for the feature will be same as Admin Configuration parameters
but will not be operational in the system(hardware).
init '(1)', In this state all Operational(local) parameters
for the feature will be same as Admin Configuration Parameters.
rxrecommended '(2)', In this state all the Operational(local)
parameters for the feature will be same as particular
feature Remote Parameters.
internallypropagated '(3)', In this state all the Operational(local)
parameters for the feature will be same as the internal propagated
information from the config source."
SYNTAX INTEGER { off(0), init(1), rxrecommended(2), internallypropagated(3) }
DcbStateMachineType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"asymmetric'(1)',By using this state machine the operational parameters
for the DCB feature can be same as peer or not.
symmetric '(2)',By using this state machine the operational parameters
for the DCB feature will be same as peer.
feature '(3)' Feature State machine as used by legacy DCBX - CIN/CEE
versions."
SYNTAX INTEGER { asymmetric(1), symmetric(2), feature(3) }
DcbxPortRole ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"."
SYNTAX INTEGER {
manual(1),
autoup(2),
autodown(3),
configSource(4)
}
DcbxVersion ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"."
SYNTAX INTEGER {
auto(1),
ieee(2),
cin(3),
cee(4)
}
-- ****************************************************************************
-- Groups in the MIB
-- ****************************************************************************
dF10DcbSystem OBJECT IDENTIFIER ::= { dF10Dcb 1 }
dF10DcbObjects OBJECT IDENTIFIER ::= { dF10Dcb 2 }
dF10DcbApplicationObjects OBJECT IDENTIFIER ::= { dF10Dcb 3 }
dF10DcbNotificationObjects OBJECT IDENTIFIER ::= { dF10Dcb 4 }
dF10DCBXObjects OBJECT IDENTIFIER ::= { dF10DcbApplicationObjects 1 }
dF10ETSObjects OBJECT IDENTIFIER ::= { dF10DcbApplicationObjects 2 }
dF10PFCObjects OBJECT IDENTIFIER ::= { dF10DcbApplicationObjects 3 }
dF10DCBXScalars OBJECT IDENTIFIER ::= { dF10DCBXObjects 1 }
dF10ETSScalars OBJECT IDENTIFIER ::= { dF10ETSObjects 1 }
dF10PFCScalars OBJECT IDENTIFIER ::= { dF10PFCObjects 1 }
-- ****************************************************************************
-- DCB Scalar MIB Objects
-- ****************************************************************************
dF10DcbPfcMinThreshold OBJECT-TYPE
SYNTAX Unsigned32 ( 1..65535 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum PFC(Priority Based Flow Control) threshold for the switch.
This Object indicates the minimum Receive queue buffer count.
The minimum and maximum values for this object may vary based on the
underlying hardware's capacity."
::= { dF10DcbSystem 1 }
dF10DcbPfcMaxThreshold OBJECT-TYPE
SYNTAX Unsigned32 ( 1..65535 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum PFC(Priority Based Flow Control)threshold for the switch.
This Object indicates the maximum Receive queue buffer count.
The minimum and maximum values for this object may vary based
on the underlying hardware's capacity. "
::= { dF10DcbSystem 2 }
dF10DcbMaxPfcProfiles OBJECT-TYPE
SYNTAX Unsigned32 (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of PFC(Priority Based Flow Control)profiles supported
by the device.
A PFC profile is a bitmap, containing the status of PFC for all the
priorities.
If Bit 0 is set, then it means PFC is enabled for priority 0, otherwise
PFC is disabled for priority 0.
If Bit 1 is set, then it means PFC is enabled for priority 1, otherwise
PFC is disabled for priority 1, and so on.
If this object value is zero, it means all the bits are set to zero and
PFC is disabled for all priorities.
If this object's value is 3, it means the bits 0 and 1 are set and
PFC is enabled for priorities 0 and 1 and disabled for all other priorities.
Device supporting 256 PFC profiles, means all possible combination of
PFC status on 8 priorities are supported. "
DEFVAL { 256 }
::= { dF10DcbSystem 3}
-- ****************************************************************************
-- DCB Port Configuration MIB Objects
-- ****************************************************************************
dF10DcbPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DF10DcbPortEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Port table contains the DCB features
(Enhanced Transmission Selection/Priortiy Based Flow Control)
status (enabled or disabled)."
::= { dF10DcbObjects 1 }
dF10DcbPortEntry OBJECT-TYPE
SYNTAX DF10DcbPortEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"An entry containing DCB control parameters for a particular port."
INDEX {dF10DcbPortNumber}
::= { dF10DcbPortTable 1 }
DF10DcbPortEntry ::=
SEQUENCE {
dF10DcbPortNumber InterfaceIndex,
dF10DcbETSAdminStatus EnabledStatus,
dF10DcbPFCAdminStatus EnabledStatus
}
dF10DcbPortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"This indicates the interface identifier for which the Dcb
configuration is applied."
::= { dF10DcbPortEntry 1 }
dF10DcbETSAdminStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This object is used to display if ETS feature is
enabled or disabled on the given port."
DEFVAL { enabled }
::= { dF10DcbPortEntry 2 }
dF10DcbPFCAdminStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This object is used to display if PFC feature is
enabled or disabled on the given port."
DEFVAL { enabled }
::= { dF10DcbPortEntry 3 }
-- ****************************************************************************
-- DCBX Scalar Objects
-- ****************************************************************************
dF10DcbxGlobalTraceLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable Trace Statements in DCBX Module.
A FOUR BYTE integer is used for enabling the level of tracing.
Each BIT in the four byte integer represents a particular
level of Trace.
The mapping between the bit positions & the level of trace is
as follows:
1 - Management Traces
2 - DCBX State Machine Traces
3 - TLV Traces
4 - System Resource Traces
5 - Failure Traces
6 - Configuration Exchange Traces
7 - Auto Detection Traces
The remaining bits are unused.
The user has to enter the corresponding INTEGER VALUE for the
trace to be set. Only one trace can be enabled at a time.
To enable all the traces, sum of all individual
traces must be provided."
::= { dF10DCBXScalars 1 }
dF10DCBXGlobalVersion OBJECT-TYPE
SYNTAX DcbxVersion
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CIN is Cisco Intel Nuova DCBX (version 1.0).
CEE is converged enhanced ethernet DCBX (version 1.06).
IEEE is 802-1 az version.
The default value is auto.
DCBX supports the legacy implementations v1.0 (CIN) and
v1.06 (CEE) in addition to standard IEEE version 2.4 DCBX.
1.DCBX starts in standard IEEE mode by sending an IEEE
standard version 2.4 DCBX frame. If the peer responds,
then IEEE standard version 2.4 DCBX is used,Starts means
after a link up, a DCBX timeout (or multiple peer
condition) or when commanded by the network operator.
If DCBX receives a DCBX frame with an OUI indicating a
legacy version, it immediately switches into legacy mode
for the detected version and does not wait for the
3x LLDP fast timeout.
2.If no IEEE DCBX response is received within 3 times the
LLDP fast transmit timeout period, DCBX immediately
transmits a version 1.06 DCBX frame with the
appropriate version number. If DCBX receives a DCBX
frame with an OUI indicating IEEE standard support,
it immediately switches into IEEE standard mode and
does not wait for the timer. If DCBX receives a DCBX
frame with an OUI indicating legacy mode and a version
number indicating version 1.0 support, it immediately
switches into legacy 1.0 mode and does not wait for the
timer.
3.If no version 1.06 response is received within 3 times
the DCBX fast transmit timeout period, DCBX falls back
to version 1.0 and immediately transmits a version 1.0
frame. If no response is received within 3 times the
DCBX fast transmit period, DCBX waits the standard LLDP
timeout period, and then begins again with step 1. If
DCBX receives a DCBX frame with an OUI indicating IEEE
standard mode, it immediately switches into IEEE
standard mode."
DEFVAL { 1 }
::= { dF10DCBXScalars 2 }
-- ****************************************************************************
-- DCBX Port Configuration MIB Objects
-- ****************************************************************************
dF10DCBXPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DF10DCBXPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port table contains the DCBX feature status (enabled or disabled)."
::= { dF10DCBXObjects 2 }
dF10DCBXPortEntry OBJECT-TYPE
SYNTAX DF10DCBXPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing DCBX control parameters for a particular port."
INDEX {dF10DCBXPortNumber}
::= { dF10DCBXPortTable 1 }
DF10DCBXPortEntry ::=
SEQUENCE {
dF10DCBXPortNumber InterfaceIndex,
dF10DCBXAdminStatus EnabledStatus,
dF10DCBXAutoCfgPortRole DcbxPortRole,
dF10DCBXPortVersion DcbxVersion,
dF10DCBXPortSupportedTLVs BITS,
dF10DCBXPortConfigTLVsTxEnable BITS
}
dF10DCBXPortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This indicates the interface identifier for which the DCBX
configuration is applied."
::= { dF10DCBXPortEntry 1 }
dF10DCBXAdminStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to display if DCBX feature is
enabled(1) or disabled(2) on the given port."
DEFVAL { enabled }
::= { dF10DCBXPortEntry 2 }
dF10DCBXAutoCfgPortRole OBJECT-TYPE
SYNTAX DcbxPortRole
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Ports operating in the manual role do not have their
configuration affected by peer devices or by internal
propagation of configuration. These ports will advertise
their configuration to their peer if DCBX is enabled
on that port.
Auto-up: Advertises a configuration, but is also willing
to accept a configuration from the link-partner and
propagate it internally to the auto-downstream ports
as well as receive configuration propagated internally
by other auto-upstream ports.
Auto-down: Advertises a configuration but is not willing
to accept one from the link partner. However, the port
will accept a configuration propagated internally by the
configuration source.
Configuration Source:In this role, the port has been
manually selected to be the configuration source.
Configuration received over this port is propagated
to the other auto-configuration ports."
DEFVAL { 1 }
::= { dF10DCBXPortEntry 3 }
dF10DCBXPortVersion OBJECT-TYPE
SYNTAX DcbxVersion
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CIN is Cisco Intel Nuova DCBX (version 1.0).
CEE is converged enhanced ethernet DCBX (version 1.06).
IEEE is 802-1 az version.
The default value is auto.
DCBX supports the legacy implementations v1.0 (CIN) and
v1.06 (CEE) in addition to standard IEEE version 2.4 DCBX.
1.DCBX starts in standard IEEE mode by sending an IEEE
standard version 2.4 DCBX frame. If the peer responds,
then IEEE standard version 2.4 DCBX is used,Starts means
after a link up, a DCBX timeout (or multiple peer
condition) or when commanded by the network operator.
If DCBX receives a DCBX frame with an OUI indicating a
legacy version, it immediately switches into legacy mode
for the detected version and does not wait for the
3x LLDP fast timeout.
2.If no IEEE DCBX response is received within 3 times the
LLDP fast transmit timeout period, DCBX immediately
transmits a version 1.06 DCBX frame with the
appropriate version number. If DCBX receives a DCBX
frame with an OUI indicating IEEE standard support,
it immediately switches into IEEE standard mode and
does not wait for the timer. If DCBX receives a DCBX
frame with an OUI indicating legacy mode and a version
number indicating version 1.0 support, it immediately
switches into legacy 1.0 mode and does not wait for the
timer.
3.If no version 1.06 response is received within 3 times
the DCBX fast transmit timeout period, DCBX falls back
to version 1.0 and immediately transmits a version 1.0
frame. If no response is received within 3 times the
DCBX fast transmit period, DCBX waits the standard LLDP
timeout period, and then begins again with step 1. If
DCBX receives a DCBX frame with an OUI indicating IEEE
standard mode, it immediately switches into IEEE
standard mode."
DEFVAL { 1 }
::= { dF10DCBXPortEntry 4 }
dF10DCBXPortSupportedTLVs OBJECT-TYPE
SYNTAX BITS {
pfc(0),
etsConfig(1),
etsRecom(2),
applicationPriorityFCOE(3),
applicationPriorityISCSI(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bitmap that includes the supported set of DCBX LLDP
TLVs the device is capable of and whose transmission is allowed on
the local LLDP agent by network management.
Having the bit 'pfc(0)' set indicates that the LLDP
transmit PFC TLV as part of DCBX TLVs.
Having the bit 'etcConfig(1)' set indicates that the LLDP
transmit ETS configuration TLV as part of DCBX TLVs.
Having the bit 'etsRecom(2)' set indicates that
transmit ETS Recommendation TLV as part of DCBX TLVs.
Having the bit 'applicationPriorityFCOE(3)' set indicates that
the LLDP transmit applicationPriority TLV for FCOE as part of
DCBX TLVs.
Having the bit 'applicationPriorityISCSI(4)' set indicates that
the LLDP transmit applicationPriority TLV for ISCSI as part of
DCBX TLVs."
::= { dF10DCBXPortEntry 5 }
dF10DCBXPortConfigTLVsTxEnable OBJECT-TYPE
SYNTAX BITS {
pfc(0),
etsConfig(1),
etsRecom(2),
applicationPriorityFCOE(3),
applicationPriorityISCSI(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bitmap that includes the DCBX defined set of LLDP
TLVs whose transmission is enabled on the local LLDP agent by
network management.
Having the bit 'pfc(0)' set indicates that the LLDP
transmit PFC TLV as part of DCBX TLVs.
Having the bit 'etsConfig(1)' set indicates that the LLDP
transmit ETS configuration TLV as part of DCBX TLVs.
Having the bit 'etsRecom(2)' set indicates that
transmit ETS Recommendation TLV as part of DCBX TLVs.
Having the bit 'applicationPriorityFCOE(3)' set indicates that
the LLDP transmit applicationPriority TLV for FCOE as part of
DCBX TLVs.
Having the bit 'applicationPriorityISCSI(4)' set indicates that
the LLDP transmit applicationPriority TLV for ISCSI as part of
DCBX TLVs."
::= { dF10DCBXPortEntry 6 }
-- ****************************************************************************
-- DCBX Statistics
-- ****************************************************************************
dF10DCBXPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DF10DCBXPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
::= { dF10DCBXObjects 3 }
dF10DCBXPortStatusEntry OBJECT-TYPE
SYNTAX DF10DCBXPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
AUGMENTS { dF10DCBXPortEntry }
::= { dF10DCBXPortStatusTable 1 }
DF10DCBXPortStatusEntry::=
SEQUENCE {
dF10DCBXPortOperVersion
DcbxVersion,
dF10DCBXPortPeerMACaddress
MacAddress,
dF10DCBXPortCfgSource
INTEGER,
dF10DCBXOperStatus
EnabledStatus,
dF10DCBXPortMultiplePeerCount
Counter32,
dF10DCBXPortPeerRemovedCount
Counter32,
dF10DCBXPortPeerOperVersionNum
Unsigned32,
dF10DCBXPortPeerMaxVersion
Unsigned32,
dF10DCBXPortSeqNum
Unsigned32,
dF10DCBXPortAckNum
Unsigned32,
dF10DCBXPortPeerRcvdAckNum
Unsigned32,
dF10DCBXPortTxCount
Counter32,
dF10DCBXPortRxCount
Counter32,
dF10DCBXPortErrorFramesCount
Counter32
}
dF10DCBXPortOperVersion OBJECT-TYPE
SYNTAX DcbxVersion
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the DCBX mode in which the interface is
currently operating."
DEFVAL { 1 }
::= { dF10DCBXPortStatusEntry 2 }
dF10DCBXPortPeerMACaddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC Address of the DCBX peer."
::= { dF10DCBXPortStatusEntry 3 }
dF10DCBXPortCfgSource OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if this port is the source of configuration
information for auto-* ports."
::= { dF10DCBXPortStatusEntry 4 }
dF10DCBXOperStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives information on the operational status of
DCBX on the given port.
Enabled(1) indicates DCBX on the port is in sync with the
remote and is operationally up.
Disabled(2) indicates DCBX on the port is operationally
disabled."
::= { dF10DCBXPortStatusEntry 5 }
dF10DCBXPortMultiplePeerCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates number of times multiple peers were detected.
A duplicate peer is when more than one DCBX peer is
detected on a port."
::= { dF10DCBXPortStatusEntry 6 }
dF10DCBXPortPeerRemovedCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"."
::= { dF10DCBXPortStatusEntry 7 }
dF10DCBXPortPeerOperVersionNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the operational version of the peer DCBX device.
Valid only when peer device is a CEE/CIN DCBX device."
::= { dF10DCBXPortStatusEntry 8 }
dF10DCBXPortPeerMaxVersion OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the max version of the peer DCBX device.
Valid only when peer device is CEE/CIN DCBX device."
::= { dF10DCBXPortStatusEntry 9 }
dF10DCBXPortSeqNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the current sequence number that is sent
in DCBX control TLVs in CEE/CIN Mode."
::= { dF10DCBXPortStatusEntry 10 }
dF10DCBXPortAckNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the current ACK number that is to be sent
to peer in DCBX control TLVs in CEE/CIN Mode."
::= { dF10DCBXPortStatusEntry 11 }
dF10DCBXPortPeerRcvdAckNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the current ACK number that is sent by peer
in DCBX control TLV in CEE/CIN Mode."
::= { dF10DCBXPortStatusEntry 12 }
dF10DCBXPortTxCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DCBX frames transmitted per interface."
::= { dF10DCBXPortStatusEntry 13 }
dF10DCBXPortRxCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DCBX frames received per interface."
::= { dF10DCBXPortStatusEntry 14 }
dF10DCBXPortErrorFramesCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DCBX frames discarded due to errors in the frame."
::= { dF10DCBXPortStatusEntry 15 }
-- ****************************************************************************
-- ETS Scalar Objects
-- ****************************************************************************
dF10ETSSystemControl OBJECT-TYPE
SYNTAX INTEGER { running(1), shutdown(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ETS(Enhanced Transmission selection) system control status
for the switch.
It indicates whether ETS Module in the system is
running or shutdown. When this object returns 'running',
resources required by ETS module are allocated and
the module is running. When this object returns 'shutdown',
all the pools used by ETS module are released to the system."
DEFVAL { running }
::= { dF10ETSScalars 1 }
dF10ETSModuleStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ETS(Enhanced Transmission Selection) Module status for the switch.
If this object returns with 'disabled', then all the ports
have the ETS feature disabled in the system(hardware)
and the DCBX state machine has stopped on the ports.
If this object returns with 'enabled', then all the ports
have the ETS feature enabled in the system(hardware)
and the DCBX state machine is running on the ports."
DEFVAL { enabled }
::= { dF10ETSScalars 2 }
dF10ETSClearCounters OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object when set to TRUE, clears the following counters
for the ETS Module:
dF10ETSConfTxTLVCounter,
dF10ETSConfRxTLVCounter,
dF10ETSConfRxTLVErrors,
dF10ETSRecoTxTLVCounter,
dF10ETSRecoRxTLVCounter,
dF10ETSRecoRxTLVErrors.
Setting this object to FALSE has no effect.
This object always returns FALSE when read."
DEFVAL { false }
::= {dF10ETSScalars 3 }
dF10ETSGlobalEnableTrap OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether the transmission of TRAP
notification messages for ETS feature is enabled or disabled."
DEFVAL { 0 }
::= { dF10ETSScalars 4 }
-- ****************************************************************************
-- ETS Port Configuration table
-- ****************************************************************************
dF10ETSPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DF10ETSPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ETS Port table contains the ETS (Enhanced Transmission Selection) features
information specific to this port.
An entry created in this table in the following tables in the standard
DCBX Mib for this port.
lldpXdot1dcbxConfigTCSupportedTable,
lldpXdot1dcbxConfigETSConfigurationTable,
lldpXdot1dcbxConfigETSRecommendationTable,
lldpXdot1dcbxLocTCSupportedTable,
lldpXdot1dcbxLocETSBasicConfigurationTable,
lldpXdot1dcbxLocETSConPriorityAssignmentTable,
lldpXdot1dcbxLocETSRecommendationTable,
lldpXdot1dcbxAdminTCSupportedTable,
lldpXdot1dcbxAdminETSBasicConfigurationTable,
lldpXdot1dcbxAdminETSConPriorityAssignmentTable,
lldpXdot1dcbxAdminETSRecommendationTable.
Deletion of entry in this table deletes all the entries in the above tables
in the standatd DCBX mib for this port."
::= { dF10ETSObjects 2 }
dF10ETSPortEntry OBJECT-TYPE
SYNTAX DF10ETSPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing ETS control parameters and ETS information
for a particular port."
INDEX {dF10ETSPortNumber}
::= { dF10ETSPortTable 1 }
DF10ETSPortEntry ::=
SEQUENCE {
dF10ETSPortNumber InterfaceIndex,
dF10ETSAdminMode DcbAdminMode,
dF10ETSDcbxOperState DcbState,
dF10ETSDcbxStateMachine DcbStateMachineType,
dF10ETSOperStatus EnabledStatus,
dF10ETSClearTLVCounters TruthValue,
dF10ETSConfTxTLVCounter Counter32,
dF10ETSConfRxTLVCounter Counter32,
dF10ETSConfRxTLVErrors Counter32,
dF10ETSRecoTxTLVCounter Counter32,
dF10ETSRecoRxTLVCounter Counter32,
dF10ETSRecoRxTLVErrors Counter32
}
dF10ETSPortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This indicates the interface identifier for which the ETS
configuration is applied."
::= { dF10ETSPortEntry 1 }
dF10ETSAdminMode OBJECT-TYPE
SYNTAX DcbAdminMode
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to display the Admin mode for ETS feature on
the given port.
If the mode is 'on(1)',ETS feature is enabled on this port.
ETS configurations, either from this system or
the remote system will take effect based on DCBX negotiations.
If the mode is 'off(2)', ETS feature is disabled on this port.
Operational(local) parameters is same as Admin Configuration
Parameters. But Operational(local) parameters do not have any impact
in the system and dF10ETSOperState is in 'Off' state.
dF10ETSDcbxOperState becomes oper up if remote is also disabled.
The Operational(local) parameters do not have any impact in
the system if this object value is 'on(1)' and
dF10ETSModuleStatus is disabled. dF10ETSDcbxOperState will
be in 'Off' State."
DEFVAL { on }
::= { dF10ETSPortEntry 2 }
dF10ETSDcbxOperState OBJECT-TYPE
SYNTAX DcbState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to display the current state of the
DCBX state machine for the ETS feature on the given port.
If state is Off '(0)', then ETS Operational(local) parameters
will be same as ETS Admin Configuration Parameters and will
not have any impact in the system(hardware).
If state is init '(1)', then ETS Operational(local) parameters
will be same as ETS Admin Configuration Parameters.
If state is rxrecommended '(2)', then ETS Operational(local) parameters
will be same as ETS Remote Parameters.
internallypropagated '(3)', In this state all the Operational(local)
parameters for the feature will be same as the internal propagated
information from the config source."
::= { dF10ETSPortEntry 3 }
dF10ETSDcbxStateMachine OBJECT-TYPE
SYNTAX DcbStateMachineType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to display the DCBX state machine
type that is used by the ETS feature on the given port."
::= { dF10ETSPortEntry 4 }
dF10ETSOperStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives information on the operational status of ETS
on the given port.
Enabled(1) indicates ETS on the port is in sync with the remote
and is operationally up.
Disabled(2) indicates ETS on the port is operationally disabled."
::= { dF10ETSPortEntry 5 }
dF10ETSClearTLVCounters OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object when set to TRUE, clears the following counters
associated with a Port:
dF10ETSConfTxTLVCounter,
dF10ETSConfRxTLVCounter,
dF10ETSConfRxTLVErrors,
dF10ETSRecoTxTLVCounter,
dF10ETSRecoRxTLVCounter,
dF10ETSRecoRxTLVErrors.
Setting this object to FALSE has no effect.
This object always returns FALSE when read."
DEFVAL { false }
::= { dF10ETSPortEntry 6 }
dF10ETSConfTxTLVCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of the number of ETS
configuration TLV that are transmitted from this port.
This counter will be incremented every time when there
is ETS Configuration TLV is generated and transmitted
to the LLDP."
::= { dF10ETSPortEntry 7 }
dF10ETSConfRxTLVCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of the number of ETS
ConfigurationTLV that are received in this port. This
counter will be incremented every time when there is ETS
Configuration TLV is received from the LLDP."
::= { dF10ETSPortEntry 8 }
dF10ETSConfRxTLVErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of number of malformed
ETS Conf TLVs received by ETS. This counter will be
incremented every time a ETS Conf TLV is dropped by ETS."
::= { dF10ETSPortEntry 9 }
dF10ETSRecoTxTLVCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of the number of ETS
Recommendation TLV that are transmitted from this port.
This counter will be incremented every time when there
is ETS Recommendation TLV is generated and transmitted
to the LLDP."
::= { dF10ETSPortEntry 10 }
dF10ETSRecoRxTLVCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of the number of ETS
Recommendation TLV that are received in this port. This
counter will be incremented every time when there is ETS
Recommendation TLV is received from the LLDP."
::= { dF10ETSPortEntry 11 }
dF10ETSRecoRxTLVErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of number of malformed
ETS Reco TLVs received by ETS. This counter will be
incremented every time a ETS Reco TLV is dropped by ETS."
::= { dF10ETSPortEntry 12 }
-- ****************************************************************************
-- PFC Scalar Objects
-- ****************************************************************************
dF10PFCSystemControl OBJECT-TYPE
SYNTAX INTEGER { running(1), shutdown(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PFC(Priority Based Flow Control) system control status for the switch.
It indicates whether PFC Module in the system is
running or shutdown. When this object returns 'running',
resources required by PFC module are allocated and
the module is running. When this object returns 'shutdown',
all the pools used by PFC module are released to the system."
DEFVAL { running }
::= { dF10PFCScalars 1 }
dF10PFCModuleStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PFC(Priority Based Flow Control) Module status for the switch.
If this object returns with 'disabled', then all the ports
have the PFC feature disabled in the system(hardware)
and the DCBX state machine has stopped on the ports.
If this object returns with 'enabled', then all the ports
have the PFC feature enabled in the system(hardware)
and the DCBX state machine is running on the ports."
DEFVAL { enabled }
::= { dF10PFCScalars 2 }
dF10PFCClearCounters OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object when set to TRUE, clears the following counters
for the PFC Module:
dF10PFCTxTLVCounter,
dF10PFCRxTLVCounter,
dF10PFCRxTLVErrors.
Setting this object to FALSE has no effect.
This object always returns FALSE when read."
DEFVAL { false }
::= {dF10PFCScalars 3 }
dF10PFCGlobalEnableTrap OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether the transmission of TRAP
notification messages for PFC feature is enabled or disabled."
DEFVAL { 0 }
::= { dF10PFCScalars 4 }
-- ****************************************************************************
-- PFC Port Configuration table
-- ****************************************************************************
dF10PFCPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DF10PFCPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PFC Port table contains the PFC (Priortiy Based Flow Control) features
information specific to this port.
An entry created in the port table populates the entry in this table and
in the following tables in the standard DCBX Mib for this port.
lldpXdot1dcbxConfigPFCTable,
lldpXdot1dcbxLocPFCBasicTable,
lldpXdot1dcbxLocPFCEnableTable,
lldpXdot1dcbxAdminPFCBasicTable,
lldpXdot1dcbxAdminPFCEnableTable.
Deletion of entry in the port table deletes the entry in this table and
all the entries in the above tables in the standatd DCBX mib for this port."
::= { dF10PFCObjects 2 }
dF10PFCPortEntry OBJECT-TYPE
SYNTAX DF10PFCPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing PFC control parameters and PFC information
for a particular port."
INDEX {dF10PFCPortNumber}
::= { dF10PFCPortTable 1 }
DF10PFCPortEntry ::=
SEQUENCE {
dF10PFCPortNumber InterfaceIndex,
dF10PFCAdminMode DcbAdminMode,
dF10PFCDcbxOperState DcbState,
dF10PFCDcbxStateMachine DcbStateMachineType,
dF10PFCOperStatus EnabledStatus,
dF10PFCClearTLVCounters TruthValue,
dF10PFCTxTLVCounter Counter32,
dF10PFCRxTLVCounter Counter32,
dF10PFCRxTLVErrors Counter32
}
dF10PFCPortNumber OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This indicates the interface identifier for which the PFC
configuration is applied."
::= { dF10PFCPortEntry 1 }
dF10PFCAdminMode OBJECT-TYPE
SYNTAX DcbAdminMode
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to display Admin mode for PFC feature on
the given port.
If mode is 'on(1)',PFC feature is enabled on this port.
PFC configurations, either from this system or
the remote system will take effect based on DCBX negotiations.
If mode is 'off(2)',PFC feature is disabled on this port.
Operational(local) parameters is same as Admin Configuration
Parameters. But Operational(local) parameters do not have any impact
in the system.dF10PFCDcbxOperState becomes up if remote is also disabled
The Operational(local) parameters do not have any impact in
the system if this object value is 'on(1)'
and dF10PFCModuleStatus is disabled. dF10PFCDcbxOperState
will be in 'Off' State."
DEFVAL { on }
::= { dF10PFCPortEntry 2 }
dF10PFCDcbxOperState OBJECT-TYPE
SYNTAX DcbState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to display the current state of the
DCBX state machine for the PFC feature on the given port.
If state is Off '(0)', then PFC Operational(local) parameters
will be same as PFC Admin Configuration Parameters and will
not have any impact in the system(hardware).
If state is init '(1)', then PFC Operational(local) parameters
will be same as PFC Admin Configuration Parameters.
If state is rxrecommended '(2)',then PFC Operational(local) parameters
will be same as PFC Remote Parameters.
internallypropagated '(3)', In this state all the Operational(local)
parameters for the feature will be same as the internal propagated
information from the config source."
::= { dF10PFCPortEntry 3 }
dF10PFCDcbxStateMachine OBJECT-TYPE
SYNTAX DcbStateMachineType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to display the DCBX state machine
type that is used by the PFC feature on the given port."
::= { dF10PFCPortEntry 4 }
dF10PFCOperStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives information on the operational status of PFC
on the given port.
Enabled(1) indicates PFC on the port is in sync with the remote
and is operationally up.
Disabled(2) indicates PFC on the port is operationally disabled."
::= { dF10PFCPortEntry 5 }
dF10PFCClearTLVCounters OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object when set to TRUE, clears the following counters
associated with a Port:
dF10PFCTxTLVCounter,
dF10PFCRxTLVCounter,
dF10PFCRxTLVErrors.
Setting this object to FALSE has no effect.
This object always returns FALSE when read."
DEFVAL { false }
::= { dF10PFCPortEntry 6 }
dF10PFCTxTLVCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of the number of PFC TLV
that are transmitted from this port. This counter will be
incremented every time when there is PFC TLV is generated
and transmitted to the LLDP."
::= { dF10PFCPortEntry 7 }
dF10PFCRxTLVCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of the number of PFC TLV
that are received in this port. This counter will be
incremented every time when there is PFC TLV is received
from the LLDP."
::= { dF10PFCPortEntry 8 }
dF10PFCRxTLVErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to keep track of number of malformed TLVs received by PFC.
This counter will be incremented every time a PFC-TLV is dropped by PFC."
::= { dF10PFCPortEntry 9 }
-- ****************************************************************************
-- dF10DCbNotification subtree contains the objects related to notifications.
-- ****************************************************************************
dF10DCBTraps OBJECT IDENTIFIER ::= { dF10DcbNotificationObjects 0 }
dF10DCBTrapObjects OBJECT IDENTIFIER ::= { dF10DcbNotificationObjects 1 }
dF10DcbTrapPortNumber OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object refers to the Port number for which the DCBX feature
is enabled. And will be used in sending the feature port specific Traps."
::= { dF10DCBTrapObjects 1 }
dF10DcbPeerUpStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object refers to the DCBX Peer Up or Peer down status
on the port.
If the value is 'true', then the DCBX Peer will be present
and UP.
If the value is 'false', then the DCBX Peer will be absent
and DOWN."
::= { dF10DCBTrapObjects 2 }
dF10ETSModuleStatusTrap NOTIFICATION-TYPE
OBJECTS {
dF10ETSModuleStatus
}
STATUS current
DESCRIPTION
"This trap is generated when there is a change in the ETS Module
status. This trap is generated only if dF10ETSGlobalEnableTrap
is enabled to send the trap."
::= { dF10DCBTraps 1 }
dF10ETSPortAdminStatusTrap NOTIFICATION-TYPE
OBJECTS {
dF10DcbTrapPortNumber,
dF10ETSAdminMode
}
STATUS current
DESCRIPTION
"This trap is generated in the following conditions.
Whenever there is a change in the ETS Admin status and the
dF10ETSGlobalEnableTrap is enabled to send the trap
for ETS Admin mode change. "
::= {dF10DCBTraps 2 }
dF10ETSPortPeerStatusTrap NOTIFICATION-TYPE
OBJECTS {
dF10DcbTrapPortNumber,
dF10DcbPeerUpStatus
}
STATUS current
DESCRIPTION
"This trap is generated in the following conditions.
Whenever there is a change in the DCBX Peer Status and the
dF10ETSGlobalEnableTrap is enabled
to send the trap for Peer Up or Peer Down."
::= {dF10DCBTraps 3 }
dF10ETSPortDcbxOperStateTrap NOTIFICATION-TYPE
OBJECTS {
dF10DcbTrapPortNumber,
dF10ETSDcbxOperState
}
STATUS current
DESCRIPTION
"This trap is generated in the following conditions.
Whenever there is a change in the ETS Operational State and the
dF10ETSGlobalEnableTrap is enabled
to send the trap for ETS state machine state change."
::= {dF10DCBTraps 4 }
dF10PFCModuleStatusTrap NOTIFICATION-TYPE
OBJECTS {
dF10PFCModuleStatus
}
STATUS current
DESCRIPTION
"This trap is generated when there is a change in the PFC Module
status is enabled. This trap is generated only if
dF10PFCGlobalEnableTrap is enabled to send the trap."
::= { dF10DCBTraps 5 }
dF10PFCPortAdminStatusTrap NOTIFICATION-TYPE
OBJECTS {
dF10DcbTrapPortNumber,
dF10PFCAdminMode
}
STATUS current
DESCRIPTION
"This trap is generated in the following conditions.
Whenever there is a change in the PFC Admin Status and the
dF10PFCGlobalEnableTrap is enabled
to send the trap for PFC Admin Status change."
::= {dF10DCBTraps 6 }
dF10PFCPortPeerStatusTrap NOTIFICATION-TYPE
OBJECTS {
dF10DcbTrapPortNumber,
dF10DcbPeerUpStatus
}
STATUS current
DESCRIPTION
"This trap is generated in the following conditions.
Whenever there is a change in the DCBX Peer Status and the
dF10PFCGlobalEnableTrap is enabled
to send the trap for Peer Up or Peer Down."
::= {dF10DCBTraps 7 }
dF10PFCPortDcbxOperStateTrap NOTIFICATION-TYPE
OBJECTS {
dF10DcbTrapPortNumber,
dF10PFCDcbxOperState
}
STATUS current
DESCRIPTION
"This trap is generated in the following conditions.
Whenever there is a change in the PFC Operational State and the
dF10PFCGlobalEnableTrap is enabled
to send the trap for PFC state machine state change."
::= {dF10DCBTraps 8 }
-- ############################################################################
-- Conformance information
-- ############################################################################
dF10DCBMibConformance OBJECT IDENTIFIER
::= { dF10Dcb 5 }
dF10DCBMibCompliances OBJECT IDENTIFIER
::= { dF10DCBMibConformance 1 }
dF10DCBMibGroups OBJECT IDENTIFIER
::= { dF10DCBMibConformance 2 }
-- ############################################################################
-- Compliance Statements
-- ############################################################################
dF10DCBMibComplianceRev1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for Dell Networking OS product which implement the
Dell Networking OS dcbx MIB. "
MODULE
MANDATORY-GROUPS {
dF10DcbSystemObjectGroup,
dF10DcbxScalarsGroup,
dF10DCBXPortTableGroup,
dF10ETSScalarsGroup,
dF10ETSPortTableGroup,
dF10PFCScalarsGroup,
dF10PFCPortTableGroup,
dF10DCBNotificationObjectsGroup,
dF10DCBNotificationsGroup
}
::= { dF10DCBMibCompliances 1 }
dF10DCBMibCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for Dell Networking OS product which implement the
Dell Networking OS dcb MIB. This module consists of the obsolete MIB objects."
MODULE
MANDATORY-GROUPS {
dF10DcbObjectGroup
}
::= { dF10DCBMibCompliances 2 }
-- ##########################################################################
-- Units of conformance
-- ##########################################################################
dF10DcbSystemObjectGroup OBJECT-GROUP
OBJECTS {
dF10DcbPfcMinThreshold,
dF10DcbPfcMaxThreshold,
dF10DcbMaxPfcProfiles
}
STATUS current
DESCRIPTION
"This group represents a collection of objects providing the
DCB system information."
::= { dF10DCBMibGroups 1 }
dF10DcbObjectGroup OBJECT-GROUP
OBJECTS {
dF10DcbETSAdminStatus,
dF10DcbPFCAdminStatus
}
STATUS obsolete
DESCRIPTION
"This group represents a collection of objects providing the
information on the DCB control parameters for a particular port."
::= { dF10DCBMibGroups 2 }
dF10DcbxScalarsGroup OBJECT-GROUP
OBJECTS {
dF10DcbxGlobalTraceLevel,
dF10DCBXGlobalVersion
}
STATUS current
DESCRIPTION
"This group represents the DCBX scalars in the DF10 DCB mib. "
::= { dF10DCBMibGroups 3 }
dF10DCBXPortTableGroup OBJECT-GROUP
OBJECTS {
dF10DCBXAdminStatus,
dF10DCBXAutoCfgPortRole,
dF10DCBXPortVersion,
dF10DCBXPortSupportedTLVs,
dF10DCBXPortConfigTLVsTxEnable,
dF10DCBXPortOperVersion,
dF10DCBXPortPeerMACaddress,
dF10DCBXPortCfgSource,
dF10DCBXOperStatus,
dF10DCBXPortMultiplePeerCount,
dF10DCBXPortPeerRemovedCount,
dF10DCBXPortPeerOperVersionNum,
dF10DCBXPortPeerMaxVersion,
dF10DCBXPortSeqNum,
dF10DCBXPortAckNum,
dF10DCBXPortPeerRcvdAckNum,
dF10DCBXPortTxCount,
dF10DCBXPortRxCount,
dF10DCBXPortErrorFramesCount
}
STATUS current
DESCRIPTION
"This group contains the collection of objects describing the
DCBX specific information on the particular port. "
::= { dF10DCBMibGroups 4 }
dF10ETSScalarsGroup OBJECT-GROUP
OBJECTS {
dF10ETSSystemControl,
dF10ETSModuleStatus,
dF10ETSClearCounters,
dF10ETSGlobalEnableTrap
}
STATUS current
DESCRIPTION
"This object represents the collection of objects providing the ETS
Information on the system."
::= { dF10DCBMibGroups 5 }
dF10ETSPortTableGroup OBJECT-GROUP
OBJECTS {
dF10ETSAdminMode,
dF10ETSDcbxOperState,
dF10ETSDcbxStateMachine,
dF10ETSOperStatus,
dF10ETSClearTLVCounters,
dF10ETSConfTxTLVCounter,
dF10ETSConfRxTLVCounter,
dF10ETSConfRxTLVErrors,
dF10ETSRecoTxTLVCounter,
dF10ETSRecoRxTLVCounter,
dF10ETSRecoRxTLVErrors
}
STATUS current
DESCRIPTION
"This object group represents the collection of objects providing
ETS specific status information on a specific port."
::= { dF10DCBMibGroups 6 }
dF10PFCScalarsGroup OBJECT-GROUP
OBJECTS {
dF10PFCSystemControl,
dF10PFCModuleStatus,
dF10PFCClearCounters,
dF10PFCGlobalEnableTrap
}
STATUS current
DESCRIPTION
"This group represents a collection of objects providing the system
information related to PFC."
::= { dF10DCBMibGroups 7 }
dF10PFCPortTableGroup OBJECT-GROUP
OBJECTS {
dF10PFCAdminMode,
dF10PFCDcbxOperState,
dF10PFCDcbxStateMachine,
dF10PFCOperStatus,
dF10PFCClearTLVCounters,
dF10PFCTxTLVCounter,
dF10PFCRxTLVCounter,
dF10PFCRxTLVErrors
}
STATUS current
DESCRIPTION
"This group represents a collection of objects providing the
PFC specific status information per port. "
::= { dF10DCBMibGroups 8 }
dF10DCBNotificationObjectsGroup OBJECT-GROUP
OBJECTS {
dF10DcbTrapPortNumber,
dF10DcbPeerUpStatus
}
STATUS current
DESCRIPTION
"This object group represents the collection of objects used by the
notification group dF10DCBNotificationsGroup."
::= { dF10DCBMibGroups 9 }
dF10DCBNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
dF10ETSModuleStatusTrap,
dF10ETSPortAdminStatusTrap,
dF10ETSPortPeerStatusTrap,
dF10ETSPortDcbxOperStateTrap,
dF10PFCModuleStatusTrap,
dF10PFCPortAdminStatusTrap,
dF10PFCPortPeerStatusTrap,
dF10PFCPortDcbxOperStateTrap
}
STATUS current
DESCRIPTION
"A collection on notification objects in the DF10-DCB mib"
::= { dF10DCBMibGroups 10 }
END