-- RBN-ATM-PVC-OAM-MIB
--
-- Copyright (c) 2002 RedBack Networks, Inc.
-- All rights reserved.
--
-- *****************************************************************
RBN-ATM-PVC-OAM-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32,
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
rbnMgmt
FROM RBN-SMI
RbnSlot, RbnPort
FROM RBN-TC;
rbnAtmPvcOamMib MODULE-IDENTITY
LAST-UPDATED "200211130000Z" -- November 13, 2002
ORGANIZATION "Redback Networks, Inc."
CONTACT-INFO
" RedBack Networks, Inc.
Postal: 300 Holger Way
San Jose, CA 95134
USA
Phone: +1 408 750 5000
Fax: +1 408 750 5599
E-mail: mib-info@redback.com
"
DESCRIPTION
"Defines the objects required to monitor the ATM PVC OAM
(Operation, Administration, and Maintenance) function.
The OAM functionality may be enabled on one or more ATM PVCs
in a system. When this functionality is enabled on a given
PVC, the system will periodically generate OAM F5 end-to-end
loopback cells on the PVC. The primary goal of this function
is to insure that an ATM PVC is brought down if the loss of
network connectivity to the remote end is detected by the
failure of the F5 OAM heartbeat cell. In addition, when this
function is enabled on a PVC, receipt of an incoming F5 OAM
VC-AIS (Virtual Circuit - Alarm Indication Signal) cell or
F5 OAM VC-RDI (Virtual Circuit - Remote Detection Indicator)
cell will also cause the associated PVC to be brought down.
"
REVISION "200211130000Z" -- November 13, 2002
DESCRIPTION
"Replaced the SYNTAX of rbnAtmPvcOamStatusSlot and
rbnAtmPvcOamStatusPort by the textual conventions RbnSlot
and RbnPort, respectively. Updated CONTACT-INFO."
REVISION "200202050000Z" -- February 5, 2002
DESCRIPTION
"Initial version."
::= { rbnMgmt 19 }
rbnAtmPvcOamMibNotifications
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMib 0 }
rbnAtmPvcOamMibObjects
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMib 1 }
rbnAtmPvcOamMibConformance
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMib 2 }
rbnAtmPvcOamStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbnAtmPvcOamStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table which contains the status of the ATM PVC OAM
function for every ATM PVC in the managed system. There
will be one entry in this table for each ATM PVC active
in the system, whether the PVC is statically configured
or was created on-demand.
"
::= { rbnAtmPvcOamMibObjects 1 }
rbnAtmPvcOamStatusEntry OBJECT-TYPE
SYNTAX RbnAtmPvcOamStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry which contains the status of the ATM PVC OAM
function for a given ATM PVC.
"
INDEX {
rbnAtmPvcOamStatusSlot,
rbnAtmPvcOamStatusPort,
rbnAtmPvcOamStatusVpi,
rbnAtmPvcOamStatusVci
}
::= { rbnAtmPvcOamStatusTable 1 }
RbnAtmPvcOamStatusEntry ::= SEQUENCE {
rbnAtmPvcOamStatusSlot RbnSlot,
rbnAtmPvcOamStatusPort RbnPort,
rbnAtmPvcOamStatusVpi Integer32,
rbnAtmPvcOamStatusVci Integer32,
rbnAtmPvcOamStatusState INTEGER
}
rbnAtmPvcOamStatusSlot OBJECT-TYPE
SYNTAX RbnSlot
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The slot containing the given ATM PVC."
::= { rbnAtmPvcOamStatusEntry 1 }
rbnAtmPvcOamStatusPort OBJECT-TYPE
SYNTAX RbnPort
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port containing the given ATM PVC."
::= { rbnAtmPvcOamStatusEntry 2 }
rbnAtmPvcOamStatusVpi OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI value of the given ATM PVC."
::= { rbnAtmPvcOamStatusEntry 3 }
rbnAtmPvcOamStatusVci OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI value of the given ATM PVC."
::= { rbnAtmPvcOamStatusEntry 4 }
rbnAtmPvcOamStatusState OBJECT-TYPE
SYNTAX INTEGER {
noOam (1),
oamUp (2),
oamDownLoopback (3),
oamDownAis (4),
oamDownRdi (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the ATM PVC OAM function on a given ATM PVC.
A value of noOam indicates the ATM PVC OAM function is not
active on the given ATM PVC
A value of oamUp indicates the ATM PVC OAM function is
active on the given ATM PVC and no failure condition is
currently being detected on the circuit
A value of oamDownLoopback indicates the ATM PVC OAM function is
active on the given ATM PVC and F5 OAM loopback cell management
has detected a fault on the circuit
A value of oamDownAis indicates the ATM PVC OAM function is
active on the given ATM PVC and a VC-AIS cell was recently
received which indicates a fault on the circuit
A value of oamDownRdi indicates the ATM PVC OAM function is
active on the given ATM PVC and a VC-RDI cell was recently
received which indicates a fault on the circuit
"
::= { rbnAtmPvcOamStatusEntry 5 }
--
-- notifications
--
rbnAtmPvcOamStatusStateChange NOTIFICATION-TYPE
OBJECTS {
rbnAtmPvcOamStatusState
}
STATUS current
DESCRIPTION
"A notification indicating that the state of an ATM PVC has
transitioned as a result of the ATM PVC OAM function. This
notification will be sent if the value of rbnAtmPvcOamStatusState
transitions from oamUp to any of the three oamDown values, or if
it transitions from any of the three oamDown values to oamUp.
"
::= { rbnAtmPvcOamMibNotifications 1 }
--
-- compliance statements
--
rbnAtmPvcOamCompliances
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMibConformance 1 }
rbnAtmPvcOamGroups
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMibConformance 2 }
rbnAtmPvcOamCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which implement
the Redback ATM PVC OAM MIB."
MODULE -- this module
MANDATORY-GROUPS {
rbnAtmPvcOamGroup,
rbnAtmPvcOamNotifyGroup
}
::= { rbnAtmPvcOamCompliances 1 }
rbnAtmPvcOamGroup OBJECT-GROUP
OBJECTS {
rbnAtmPvcOamStatusState
}
STATUS current
DESCRIPTION
"The collection of objects which allow monitoring of the
ATM PVC OAM function."
::= { rbnAtmPvcOamGroups 1 }
rbnAtmPvcOamNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS {
rbnAtmPvcOamStatusStateChange
}
STATUS current
DESCRIPTION
"The collection of notifications which allow monitoring of the
ATM PVC OAM function."
::= { rbnAtmPvcOamGroups 2 }
END