-- The Ericsson Alarm MIB
|
|
--
|
|
-- Copyright (c) 2008 by Ericsson AB.
|
|
-- All rights reserved.
|
|
--
|
|
-- This MIB is documented further in EAB/OP-07:0139
|
|
--
|
|
-- Authors:
|
|
-- Stefan Wallin (DataDuctus, primary author)
|
|
-- Vincent Desbois
|
|
-- Ulf Hallgarn
|
|
-- Tomas Jonsson
|
|
-- Peter Loborg
|
|
-- David Partain
|
|
-- Mattias Pettersson A
|
|
-- Ingemar Segerberg
|
|
-- Johan Wallin
|
|
-- Martin Wettergren
|
|
--
|
|
ERICSSON-ALARM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Unsigned32, Gauge32
|
|
FROM SNMPv2-SMI
|
|
TruthValue, DateAndTime
|
|
FROM SNMPv2-TC
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
ericssonModules
|
|
FROM ERICSSON-TOP-MIB
|
|
EriAdditionalText, EriLargeAdditionalText, EriAlarmType,
|
|
EriAlarmSequenceNumber, EriAlarmIndex,
|
|
EriAlarmSpecificProblem
|
|
FROM ERICSSON-ALARM-TC-MIB
|
|
EriProbableCause
|
|
FROM ERICSSON-ALARM-PC-MIB
|
|
EriMO
|
|
FROM ERICSSON-TC-MIB
|
|
ResourceId
|
|
FROM ALARM-MIB
|
|
ItuPerceivedSeverity
|
|
FROM ITU-ALARM-TC-MIB
|
|
IANAItuEventType
|
|
FROM IANA-ITU-ALARM-TC-MIB
|
|
snmpTargetBasicGroup
|
|
FROM SNMP-TARGET-MIB
|
|
snmpNotifyGroup
|
|
FROM SNMP-NOTIFICATION-MIB
|
|
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF;
|
|
|
|
|
|
ericssonAlarmMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200810170000Z"
|
|
ORGANIZATION "Ericsson AB"
|
|
CONTACT-INFO
|
|
"Email: snmp.mib.contact@ericsson.com "
|
|
DESCRIPTION
|
|
"See also Documentation and Use of the Ericsson
|
|
SNMP Alarm MIB, Document number EAB/OP-07:0139.
|
|
|
|
This MIB Module is an Ericsson-wide SNMP
|
|
interface for managing alarms. Main inputs to
|
|
the MIB design are the 3GPP Alarm IRP and X.733.
|
|
However, an important restriction is that the MIB
|
|
only represents the resource view and not
|
|
management activities like acknowledgment, etc.
|
|
It describes generic notifications used to send
|
|
alarm state changes and a table which represents
|
|
the current active alarms in the system. The MIB
|
|
supports both stateful alarms and stateless
|
|
alarms (that have no clear notification).
|
|
Stateless alarms are called alerts.
|
|
|
|
It is important to identify clearly what is to be
|
|
considered the same alarm object instance. All
|
|
unique alarm *types* are identified by
|
|
'AlarmType'. An AlarmType is a one-to-one
|
|
mapping with X.733 EventType, ProbabableCause and
|
|
SpecificProblem. A pair of integers are used to
|
|
specify the alarm type.
|
|
|
|
A unique alarm object *instance* is the
|
|
combination of managed object and AlarmType. In
|
|
this way there, is no ambiguity about how alarm
|
|
and alarm clear correlation should be performed:
|
|
the same managed object instance and AlarmType
|
|
shall be used. The same is true for changing
|
|
existing alarm states. Severity and
|
|
additionalText can be changed on an existing
|
|
alarm.
|
|
|
|
For stateful alarms there are notifications to
|
|
report a new alarm and a cleared alarm. Changing
|
|
an alarm is done via the new alarm notification.
|
|
The management system shall match the alarm by
|
|
using alarm type and managed object instance in
|
|
the same way as for clear notifications.
|
|
|
|
The MIB has different notifications for different
|
|
severities in order to support SNMP managers
|
|
which maps severities based on notification
|
|
identifiers. For stateless alarms, there are
|
|
generic notifications to send the alarm raise
|
|
with different severities.
|
|
|
|
A table lists all active alarms so that a manager
|
|
can read an initial state and also perform an
|
|
alarm resynchronization procedure. There is also
|
|
a table of latest stateless alarms. Since the
|
|
stateless alarms do not have a corresponding
|
|
clear message, the table size is limited by the
|
|
agent instrumentation.
|
|
|
|
The MIB supports two approaches for detecting
|
|
lost notifications:
|
|
- sequence numbers are used in the alarm
|
|
notifications, and are shown in the active
|
|
alarm table. The last used sequence number can
|
|
be read in a scalar variable
|
|
- a time stamp indicates the last time alarm
|
|
tables where updated.
|
|
|
|
Heartbeat mechanisms are supported both in pull
|
|
and push mode:
|
|
- Pull: the classical SNMP polling where a
|
|
manager polls a scalar variable, for example
|
|
the last sequence number used
|
|
- Push: the agent can be configured to send
|
|
heartbeat notifications. These contains the
|
|
last used sequence numbers.
|
|
|
|
Document number: 5/196 03-CXC 172 7549, Rev A"
|
|
REVISION "200810170000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { ericssonModules 4 }
|
|
|
|
--==========
|
|
--==Groups==
|
|
--==========
|
|
|
|
eriAlarmObjects OBJECT IDENTIFIER ::= { ericssonAlarmMIB 1 }
|
|
eriAlarmNotifications OBJECT IDENTIFIER ::= { ericssonAlarmMIB 2 }
|
|
eriAlarmNotifsPrefix OBJECT IDENTIFIER ::= { eriAlarmNotifications 0 }
|
|
eriAlarmConformance OBJECT IDENTIFIER ::= { ericssonAlarmMIB 4 }
|
|
|
|
eriAlarmSummary OBJECT IDENTIFIER ::= { eriAlarmObjects 1 } -- eriAlarmSum
|
|
eriAlarmNotifObjects OBJECT IDENTIFIER ::= { eriAlarmObjects 2 } -- eriAlarmNObj
|
|
eriAlarmActiveAlarms OBJECT IDENTIFIER ::= { eriAlarmObjects 3 } -- eriAlarmActive
|
|
eriAlarmAlerts OBJECT IDENTIFIER ::= { eriAlarmObjects 4 } -- eriAlarmAlert
|
|
eriAlarmHeartBeat OBJECT IDENTIFIER ::= { eriAlarmObjects 5 } -- eriAlarmHb
|
|
|
|
--====================
|
|
--==Alarm summary==
|
|
--====================
|
|
|
|
eriAlarmSumIndeterminate OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the number of currently active
|
|
alarms with perceived severity 'indeterminate'.
|
|
Note that only stateful alarms are included."
|
|
::= { eriAlarmSummary 1 }
|
|
|
|
eriAlarmSumCritical OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the number of currently active
|
|
alarms with perceived severity 'critical'. Note
|
|
that only stateful alarms are included."
|
|
::= { eriAlarmSummary 2 }
|
|
|
|
eriAlarmSumMajor OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the number of currently active
|
|
alarms with perceived severity 'major'. Note
|
|
that only stateful alarms are included."
|
|
::= { eriAlarmSummary 3 }
|
|
|
|
eriAlarmSumMinor OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the number of currently active
|
|
alarms with perceived severity 'minor'. Note
|
|
that only stateful alarms are included."
|
|
::= { eriAlarmSummary 4 }
|
|
|
|
eriAlarmSumWarning OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the number of currently active
|
|
alarms with perceived severity 'warning'. Note
|
|
that only stateful alarms are included."
|
|
::= { eriAlarmSummary 5 }
|
|
|
|
--=============================
|
|
-- Notification objects
|
|
--==============================
|
|
|
|
eriAlarmNObjAdditionalText OBJECT-TYPE
|
|
SYNTAX EriAdditionalText
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a scalar variable only used in
|
|
notifications. It is size ranged with a smaller
|
|
size than the corresponding type used in the
|
|
active alarm table. This is in order to make sure
|
|
that all alarm information will fit into one UDP
|
|
packet. The additional text can be further
|
|
appended by using the dedicated append
|
|
notification."
|
|
::= { eriAlarmNotifObjects 1 }
|
|
|
|
eriAlarmNObjMoreAdditionalText OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a scalar variable only used in
|
|
notifications. It tells the management system
|
|
that the additional text will be appended by
|
|
subsequent append additional text notifications.
|
|
NOTE: this object exists simply because of the
|
|
limitations of PDU size inherent in SNMP over
|
|
UDP, which limits the size of the PDU+headers to
|
|
under 1500 octets. Otherwise, the notification
|
|
will be fragmented."
|
|
::= { eriAlarmNotifObjects 2 }
|
|
|
|
|
|
eriAlarmNObjResourceId OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a scalar variable only used in
|
|
notifications. It tells the management system
|
|
that there is an SNMP-based Resource ID (OID)
|
|
that identifies the alarming resource. NOTE:
|
|
this object exists simply because of the
|
|
limitations of PDU size inherent in SNMP over
|
|
UDP, which limits the size of the PDU+headers to
|
|
under 1500 octets. Otherwise, the notification
|
|
will be fragmented."
|
|
::= { eriAlarmNotifObjects 3 }
|
|
|
|
--======================
|
|
--==Active Alarm table==
|
|
--======================
|
|
|
|
eriAlarmActiveNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the total number of currently
|
|
active alarms, i.e. the total number of entries
|
|
in the Alarm Table."
|
|
::= { eriAlarmActiveAlarms 1 }
|
|
|
|
eriAlarmActiveLastChanged OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A timestamp when the active alarm table was last
|
|
changed. The value can be used by a manager to
|
|
initiate an alarm resynchronization procedure.
|
|
NOTE: All fields of the DateAndTime MUST be
|
|
filled out, including the hours and minutes from
|
|
UTC. As such, the value should be 11 octets
|
|
long."
|
|
REFERENCE
|
|
"DateAndTime is defined in RFC 2579, page 18"
|
|
::= { eriAlarmActiveAlarms 2 }
|
|
|
|
eriAlarmActiveLastSequenceNo OBJECT-TYPE
|
|
SYNTAX EriAlarmSequenceNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last used sequence number for a alarm state
|
|
change notification. A management system can poll
|
|
this variable in order to detect lost alarm
|
|
change notifications."
|
|
::= { eriAlarmActiveAlarms 3 }
|
|
|
|
eriAlarmActiveTableURL OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A URL pointing to a location where the contents
|
|
of the alarm table can be retrieved as a file.
|
|
The actual format of the file is out of the scope
|
|
of this MIB and can be found in the system
|
|
documentation. A Uniform Resource Locator in
|
|
accordance with RFC 4248. A string of length
|
|
zero means that the agent does not have a URL to
|
|
provide."
|
|
::= { eriAlarmActiveAlarms 4 }
|
|
|
|
eriAlarmActiveAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EriAlarmActiveAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table list all active alarms in the system.
|
|
The aspect is the resource view of the alarms,
|
|
not the administrative states and processes
|
|
performed by users. The number of entries,
|
|
active alarms, can be read in
|
|
eriAlarmActiveNumber. Entries are created when a
|
|
resource has a new alarm state. If the same
|
|
resource has several active alarms, with
|
|
different Alarm Types, this will be represented
|
|
as separate rows. Rows disappear whenever the
|
|
alarm is cleared in the resource.
|
|
|
|
Rows can be changed when an alarm changes
|
|
severity or additional text. Alarms where the
|
|
clear state cannot be detected by the resource
|
|
are not represented in this table.
|
|
|
|
The contents of the active alarm table can also
|
|
be fetched using file transfer.
|
|
eriAlarmActiveTableURL provides a URL to the
|
|
file."
|
|
::= { eriAlarmActiveAlarms 5 }
|
|
|
|
eriAlarmActiveAlarmEntry OBJECT-TYPE
|
|
SYNTAX EriAlarmActiveAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One entry in the table holds one active alarm
|
|
for a given resource. Entries are created by the
|
|
system when a resource has a new alarm state.
|
|
Entries are deleted by the system when a resource
|
|
alarm state is cleared.
|
|
|
|
Alarm severity and additional text can later be
|
|
changed in a row."
|
|
INDEX {
|
|
eriAlarmActiveIndex
|
|
}
|
|
::= { eriAlarmActiveAlarmTable 1 }
|
|
|
|
EriAlarmActiveAlarmEntry ::= SEQUENCE {
|
|
eriAlarmActiveIndex EriAlarmIndex,
|
|
eriAlarmActiveMajorType EriAlarmType, -- Unique integer
|
|
eriAlarmActiveMinorType EriAlarmType, -- Unique integer
|
|
eriAlarmActiveSpecificProblem EriAlarmSpecificProblem, -- Unique text
|
|
eriAlarmActiveManagedObject EriMO, -- Distinguished Name
|
|
eriAlarmActiveEventType IANAItuEventType, -- X.733
|
|
eriAlarmActiveEventTime DateAndTime, -- Time for last state change
|
|
eriAlarmActiveOriginalEventTime DateAndTime, -- Time for alarm raise
|
|
eriAlarmActiveProbableCause EriProbableCause, -- X.733
|
|
eriAlarmActiveSeverity ItuPerceivedSeverity, -- Last state change
|
|
eriAlarmActiveOriginalSeverity ItuPerceivedSeverity, -- Alarm raise
|
|
eriAlarmActiveAdditionalText EriLargeAdditionalText, -- Last state change
|
|
eriAlarmActiveOrigAdditionalText EriLargeAdditionalText, -- Alarm raise
|
|
eriAlarmActiveResourceId ResourceId -- SNMP OID for MO
|
|
}
|
|
|
|
eriAlarmActiveIndex OBJECT-TYPE
|
|
SYNTAX EriAlarmIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each
|
|
alarm. It is recommended that values are
|
|
assigned contiguously starting from 1. The value
|
|
for each alarm must remain constant at least from
|
|
one re-initialization of the entity to the next
|
|
re-initialization. Note that this index should
|
|
not be used for alarm synchronization purposes
|
|
since the 'logical' index for an alarm is
|
|
- eriAlarmActiveMajorType
|
|
- eriAlarmActiveMinorType
|
|
- eriAlarmActiveManagedObject"
|
|
::= { eriAlarmActiveAlarmEntry 1 }
|
|
|
|
eriAlarmActiveMajorType OBJECT-TYPE
|
|
SYNTAX EriAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In combination with eriAlarmActiveMinorType,
|
|
this provides a unique identification of the
|
|
fault type. Different managed object types and
|
|
instances can share alarm types, but if the same
|
|
managed object reports the same alarm type, it is
|
|
to be considered as the same alarm state. The
|
|
alarm type is a simplification of the different
|
|
X.733 and 3GPP alarm IRP alarm correlation
|
|
mechanisms based on EventType, ProbableCause,
|
|
SpecificProblem and NotificationId. For systems
|
|
where eriAlarmActiveMajorType is not needed for
|
|
identification purposes, it is not used and MUST
|
|
be zero-valued."
|
|
::= { eriAlarmActiveAlarmEntry 2 }
|
|
|
|
eriAlarmActiveMinorType OBJECT-TYPE
|
|
SYNTAX EriAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In combination with with
|
|
eriAlarmActiveMajorType, this provides a unique
|
|
identification of the fault type, not including
|
|
the managed object. Different managed object
|
|
types and instances can share alarm types, but if
|
|
the same managed object reports the same alarm
|
|
type it is to be considered as the same alarm
|
|
state. The alarm type is a simplification of the
|
|
different X.733 and 3GPP alarm IRP alarm
|
|
correlation mechanisms based on EventType,
|
|
ProbableCause, SpecificProblem and
|
|
NotificationId."
|
|
::= { eriAlarmActiveAlarmEntry 3 }
|
|
|
|
eriAlarmActiveSpecificProblem OBJECT-TYPE
|
|
SYNTAX EriAlarmSpecificProblem
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a clear-text unique identification of
|
|
the alarm type. There is a one-to-one mapping
|
|
between eriAlarmActiveSpecificProblem and
|
|
[eriAlarmActiveMajorType,eriAlarmActiveMinorType]"
|
|
::= { eriAlarmActiveAlarmEntry 4 }
|
|
|
|
eriAlarmActiveManagedObject OBJECT-TYPE
|
|
SYNTAX EriMO
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 3GPP naming convention shall be used as
|
|
format for the managed object parameter. Note
|
|
that the granularity must be good enough to
|
|
guarantee unique alarm states and relevant
|
|
resource identification to the operator.
|
|
NOTE: The DN should be *relative* to the nodes
|
|
*own* root."
|
|
REFERENCE
|
|
"3GPP TS 32.106-8 V3.2, Name convention for
|
|
Managed Objects"
|
|
::= { eriAlarmActiveAlarmEntry 5 }
|
|
|
|
eriAlarmActiveEventType OBJECT-TYPE
|
|
SYNTAX IANAItuEventType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event type as defined in X.733/X.736."
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmActiveAlarmEntry 6 }
|
|
|
|
eriAlarmActiveEventTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A time stamp of the alarm state change event.
|
|
Note that this variable represents the last
|
|
change of the alarm state, like changed severity
|
|
or additional text. If the alarm has not changed
|
|
state this variable represents the alarm raise
|
|
time and will be the same as originalEventTime.
|
|
|
|
NOTE: All fields of the DateAndTime MUST be
|
|
filled out, including the hours and minutes from
|
|
UTC. As such, the value should be 11 octets
|
|
long."
|
|
REFERENCE
|
|
"DateAndTime is defined in RFC 2579, page 18.
|
|
ITU Recommendation X.733, 'Information Technology
|
|
- Open Systems Interconnection - System
|
|
Management: Alarm Reporting Function', 1992"
|
|
::= { eriAlarmActiveAlarmEntry 7 }
|
|
|
|
eriAlarmActiveOriginalEventTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time-stamp of the original alarm raise
|
|
notification.
|
|
NOTE: All fields of the DateAndTime MUST be
|
|
filled out, including the hours and minutes from
|
|
UTC. As such, the value should be 11 octets
|
|
long."
|
|
REFERENCE
|
|
"DateAndTime is defined in RFC 2579, page 18."
|
|
::= { eriAlarmActiveAlarmEntry 8 }
|
|
|
|
eriAlarmActiveProbableCause OBJECT-TYPE
|
|
SYNTAX EriProbableCause
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The probable cause for the alarm originally
|
|
defined by X.733 and subsequent standards. See
|
|
also the ERICSSON-ALARM-PC-MIB. Due to the
|
|
history of problems in maintaining a standardized
|
|
probable cause the probable cause is not unique.
|
|
A best effort mapping of the alarm to existing
|
|
probable causes are used."
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmActiveAlarmEntry 9 }
|
|
|
|
eriAlarmActiveSeverity OBJECT-TYPE
|
|
SYNTAX ItuPerceivedSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the alarm as defined by X.733.
|
|
Note that this may not be the original severity
|
|
since the alarm may have changed severity."
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmActiveAlarmEntry 10 }
|
|
|
|
eriAlarmActiveOriginalSeverity OBJECT-TYPE
|
|
SYNTAX ItuPerceivedSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The original severity as reported by the alarm
|
|
raise notification."
|
|
::= { eriAlarmActiveAlarmEntry 11 }
|
|
|
|
eriAlarmActiveAdditionalText OBJECT-TYPE
|
|
SYNTAX EriLargeAdditionalText
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user friendly text describing the alarm. The
|
|
text is both static depending on the alarm type
|
|
(probable cause), and dynamic depending on
|
|
managed object instance and other conditions.
|
|
This string is longer than the corresponding
|
|
varbind in the notification in order to manage
|
|
large strings."
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmActiveAlarmEntry 12 }
|
|
|
|
eriAlarmActiveOrigAdditionalText OBJECT-TYPE
|
|
SYNTAX EriLargeAdditionalText
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user-friendly text describing the alarm. The
|
|
text is both static depending on the alarm type
|
|
(probable cause), and dynamic depending on
|
|
managed object and other conditions. This is the
|
|
original text as reported by the first alarm
|
|
notification, after which it is not altered."
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmActiveAlarmEntry 13 }
|
|
|
|
eriAlarmActiveResourceId OBJECT-TYPE
|
|
SYNTAX ResourceId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case the alarm refers to an object which is
|
|
instrumented by SNMP this variable indicates the
|
|
corresponding OID for the managed object."
|
|
REFERENCE
|
|
"RFC 3877 IETF ALARM MIB"
|
|
::= { eriAlarmActiveAlarmEntry 14 }
|
|
|
|
|
|
--======================
|
|
--==Alert table==
|
|
--======================
|
|
-- This table lists the latest reported alerts.
|
|
|
|
eriAlarmAlertNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of rows in the alert table."
|
|
::= { eriAlarmAlerts 1 }
|
|
|
|
eriAlarmAlertLastChanged OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A timestamp when the alert table was last
|
|
changed. Can be used by a manager to initiate a
|
|
an update of alerts procedure.
|
|
NOTE: All fields of the DateAndTime MUST be
|
|
filled out, including the hours and minutes from
|
|
UTC. As such, the value should be 11 octets
|
|
long."
|
|
REFERENCE
|
|
"DateAndTime is defined in RFC 2579, page 18"
|
|
::= { eriAlarmAlerts 2 }
|
|
|
|
eriAlarmAlertLastSequenceNo OBJECT-TYPE
|
|
SYNTAX EriAlarmSequenceNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last sequence number used in alert
|
|
notifications. This can be used to detect a lost
|
|
notification."
|
|
::= { eriAlarmAlerts 3 }
|
|
|
|
eriAlarmAlertTableURL OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A URL pointing to a location where the contents
|
|
of alert table can be retrieved as a file. The
|
|
format of the file is out of the scope of this
|
|
MIB and system dependant. A Uniform Resource
|
|
Locator in accordance with RFC 4248."
|
|
::= { eriAlarmAlerts 4 }
|
|
|
|
eriAlarmAlertTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EriAlarmAlertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists the last alerts in the system.
|
|
An alert is a stateless alarm, that is no clear
|
|
notification will be sent. Rows in this table are
|
|
created when a new alarm event is detected. Rows
|
|
are deleted by the instrumentation at a
|
|
predefined size or age."
|
|
::= { eriAlarmAlerts 5 }
|
|
|
|
eriAlarmAlertEntry OBJECT-TYPE
|
|
SYNTAX EriAlarmAlertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One entry in the table holds one alert for a
|
|
given resource. Rows in this table are created
|
|
when a new alert is detected. Rows are deleted
|
|
by the instrumentation at a predefined size or
|
|
age."
|
|
INDEX { eriAlarmAlertIndex }
|
|
::= { eriAlarmAlertTable 1 }
|
|
|
|
EriAlarmAlertEntry ::= SEQUENCE {
|
|
eriAlarmAlertIndex EriAlarmIndex,
|
|
eriAlarmAlertMajorType EriAlarmType,
|
|
eriAlarmAlertMinorType EriAlarmType,
|
|
eriAlarmAlertSpecificProblem EriAlarmSpecificProblem,
|
|
eriAlarmAlertManagedObject EriMO,
|
|
eriAlarmAlertEventType IANAItuEventType,
|
|
eriAlarmAlertEventTime DateAndTime,
|
|
eriAlarmAlertProbableCause EriProbableCause,
|
|
eriAlarmAlertSeverity ItuPerceivedSeverity,
|
|
eriAlarmAlertAdditionalText EriLargeAdditionalText,
|
|
eriAlarmAlertResourceId ResourceId
|
|
}
|
|
|
|
eriAlarmAlertIndex OBJECT-TYPE
|
|
SYNTAX EriAlarmIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index in the alert table."
|
|
::= { eriAlarmAlertEntry 1 }
|
|
|
|
eriAlarmAlertMajorType OBJECT-TYPE
|
|
SYNTAX EriAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In combination with eriAlarmAlertMinorType, this
|
|
provides unique identification of the fault.
|
|
Different managed object types and instances can
|
|
share alarm types, but if the same managed object
|
|
reports the same alarm type it is to be
|
|
considered as the same alarm state. The alarm
|
|
type is a simplification of the different X.733
|
|
and 3GPP alarm IRP alarm correlation mechanisms
|
|
based on EventType, ProbableCause,
|
|
SpecificProblem and NotificationId."
|
|
::= { eriAlarmAlertEntry 2 }
|
|
|
|
eriAlarmAlertMinorType OBJECT-TYPE
|
|
SYNTAX EriAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In combination with eriAlarmAlertMajorType, this
|
|
provides a unique identification of the fault.
|
|
Different managed object types and instances can
|
|
share alarm types. But if the same managed object
|
|
reports the same alarm type it is to be
|
|
considered as the same alarm state. The alarm
|
|
type is a simplification of the different X.733
|
|
and 3GPP alarm IRP alarm correlation mechanisms
|
|
based on EventType, ProbableCause,
|
|
SpecificProblem and NotificationId. "
|
|
::= { eriAlarmAlertEntry 3 }
|
|
|
|
eriAlarmAlertSpecificProblem OBJECT-TYPE
|
|
SYNTAX EriAlarmSpecificProblem
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a clear-text unique identification of
|
|
the alert type. There is a one-to-one mapping
|
|
between eriAlarmAlertSpecificProblem and
|
|
[eriAlarmAlertMajorType, eriAlarmAlertMinorType]"
|
|
::= { eriAlarmAlertEntry 4 }
|
|
|
|
eriAlarmAlertManagedObject OBJECT-TYPE
|
|
SYNTAX EriMO
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 3GPP naming convention shall be used as
|
|
format for the managed object parameter. Note
|
|
that the granularity must be good enough to
|
|
guarantee relevant resource identification to the
|
|
operator.
|
|
NOTE: The DN should be *relative* to the nodes
|
|
*own* root."
|
|
REFERENCE
|
|
"3GPP TS 32.106-8 V3.2, Name convention for
|
|
Managed Objects"
|
|
::= { eriAlarmAlertEntry 5 }
|
|
|
|
eriAlarmAlertEventType OBJECT-TYPE
|
|
SYNTAX IANAItuEventType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event type as defined in X.733/X.736."
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmAlertEntry 6 }
|
|
|
|
eriAlarmAlertEventTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A time stamp of the alert. NOTE: All fields of
|
|
the DateAndTime MUST be filled out, including the
|
|
hours and minutes from UTC. As such, the value
|
|
should be 11 octets long."
|
|
REFERENCE
|
|
"DateAndTime is defined in RFC 2579, page 18.
|
|
ITU Recommendation X.733, 'Information Technology
|
|
- Open Systems Interconnection - System
|
|
Management: Alarm Reporting Function', 1992"
|
|
::= { eriAlarmAlertEntry 7 }
|
|
|
|
eriAlarmAlertProbableCause OBJECT-TYPE
|
|
SYNTAX EriProbableCause
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The probable cause for the alarm originally
|
|
defined by X.733 and subsequent standards.
|
|
See also the ERICSSON-ALARM-PC-MIB. Due to the
|
|
history of problems in maintaining a standardized
|
|
probable cause the probable cause is not unique.
|
|
A best effort mapping of the alert to existing
|
|
probable causes are used."
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmAlertEntry 8 }
|
|
|
|
eriAlarmAlertSeverity OBJECT-TYPE
|
|
SYNTAX ItuPerceivedSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the alert as defined by X.733"
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmAlertEntry 9 }
|
|
|
|
eriAlarmAlertAdditionalText OBJECT-TYPE
|
|
SYNTAX EriLargeAdditionalText
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user friendly text describing the alert. The
|
|
text is both static depending on the alert type
|
|
and dynamic depending on managed object and other
|
|
conditions."
|
|
REFERENCE
|
|
"ITU Recommendation X.733, 'Information
|
|
Technology - Open Systems Interconnection -
|
|
System Management: Alarm Reporting Function',
|
|
1992"
|
|
::= { eriAlarmAlertEntry 10 }
|
|
|
|
eriAlarmAlertResourceId OBJECT-TYPE
|
|
SYNTAX ResourceId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case the alert refers to an object which is
|
|
instrumented by SNMP this variable indicates the
|
|
corresponding OID for the managed object."
|
|
REFERENCE
|
|
"RFC 3877 IETF ALARM MIB"
|
|
|
|
::= { eriAlarmAlertEntry 11 }
|
|
|
|
--=============
|
|
-- Heartbeat
|
|
--==============
|
|
|
|
eriAlarmHbInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification eriAlarmHeartBeatNotif will be
|
|
sent every eriAlarmHbInterval. Managers can
|
|
subscribe to the notification using the SNMP
|
|
framework MIBS by using the snmpNotifyName
|
|
'heartbeat'. (SNMP-NOTIFICATION-MIB,
|
|
snmpNotifyTable)"
|
|
::= { eriAlarmHeartBeat 1 }
|
|
|
|
--====================================================
|
|
--==Notifications and notification specific objects ==
|
|
--====================================================
|
|
|
|
|
|
eriAlarmIndeterminate NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmActiveManagedObject,
|
|
eriAlarmActiveMajorType,
|
|
eriAlarmActiveMinorType,
|
|
eriAlarmActiveSpecificProblem,
|
|
eriAlarmActiveLastSequenceNo,
|
|
eriAlarmActiveEventType,
|
|
eriAlarmActiveEventTime,
|
|
eriAlarmActiveProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alarm state with severity
|
|
indeterminate. The notification is also used to
|
|
change severity and/or additional text of an
|
|
alarm. The combination of ManagedObject and
|
|
MajorType/MinorType is always unique and can be
|
|
used by management systems to correlate alarm,
|
|
alarm change, and alarm clear. A corresponding
|
|
row will be created in the Alarm Table. The
|
|
sequence number will increase for every
|
|
notification and can be used to detect lost
|
|
notifications.
|
|
|
|
A management system should be prepared for
|
|
appending text to additional text, indicated by
|
|
the eriAlarmNObjMoreAdditionalText varbind, and
|
|
sent with eriAlarmAppendInfo. (Note do not
|
|
confuse this with a change of additional text.)
|
|
|
|
A management system should also be prepared to
|
|
receive a resource ID (OID) identifying the
|
|
alarming resource if the system sending the
|
|
notification can provide that information. In
|
|
that case, eriAlarmNObjResourceId will be set to
|
|
'true' and the resource ID will be sent in an
|
|
eriAlarmAppendInfo notification."
|
|
::= { eriAlarmNotifsPrefix 1 }
|
|
|
|
eriAlarmWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmActiveManagedObject,
|
|
eriAlarmActiveMajorType,
|
|
eriAlarmActiveMinorType,
|
|
eriAlarmActiveSpecificProblem,
|
|
eriAlarmActiveLastSequenceNo,
|
|
eriAlarmActiveEventType,
|
|
eriAlarmActiveEventTime,
|
|
eriAlarmActiveProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alarm state with severity warning.
|
|
The notification is also used to change severity
|
|
and/or additional text of an alarm. The
|
|
combination of ManagedObject and
|
|
MajorType/MinorType is always unique and can be
|
|
used by management systems to correlate alarm,
|
|
alarm change, and alarm clear. A corresponding
|
|
row will be created in the Alarm Table,
|
|
(eriAlarmActiveAlarmTable). The sequence number
|
|
will increase for every notification and can be
|
|
used to detect lost notifications.
|
|
|
|
A management system should be prepared for
|
|
appending text to additional text, indicated by
|
|
the eriAlarmNObjMoreAdditionalText varbind, and
|
|
sent with eriAlarmAppendInfo. (Note do not
|
|
confuse this with a change of additional text.)
|
|
|
|
A management system should also be prepared to
|
|
receive a resource ID (OID) identifying the
|
|
alarming resource if the system sending the
|
|
notification can provide that information. In
|
|
that case, eriAlarmNObjResourceId will be set to
|
|
'true' and the resource ID will be sent in an
|
|
eriAlarmAppendInfo notification."
|
|
::= { eriAlarmNotifsPrefix 2 }
|
|
|
|
eriAlarmMinor NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmActiveManagedObject,
|
|
eriAlarmActiveMajorType,
|
|
eriAlarmActiveMinorType,
|
|
eriAlarmActiveSpecificProblem,
|
|
eriAlarmActiveLastSequenceNo,
|
|
eriAlarmActiveEventType,
|
|
eriAlarmActiveEventTime,
|
|
eriAlarmActiveProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alarm state with severity minor.
|
|
The notification is also used to change severity
|
|
and/or additional text of an alarm. The
|
|
combination of ManagedObject and
|
|
MajorType/MinorType is always unique and can be
|
|
used by management systems to correlate alarm,
|
|
alarm change, and alarm clear. A corresponding
|
|
row will be created in the Alarm Table,
|
|
(eriAlarmActiveAlarmTable). The sequence number
|
|
will increase for every notification and can be
|
|
used to detect lost notifications.
|
|
|
|
A management system should be prepared for
|
|
appending text to additional text, indicated by
|
|
the eriAlarmNObjMoreAdditionalText varbind, and
|
|
sent with eriAlarmAppendInfo. (Note do not
|
|
confuse this with a change of additional text.)
|
|
|
|
A management system should also be prepared to
|
|
receive a resource ID (OID) identifying the
|
|
alarming resource if the system sending the
|
|
notification can provide that information. In
|
|
that case, eriAlarmNObjResourceId will be set to
|
|
'true' and the resource ID will be sent in an
|
|
eriAlarmAppendInfo notification."
|
|
::= { eriAlarmNotifsPrefix 3 }
|
|
|
|
eriAlarmMajor NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmActiveManagedObject,
|
|
eriAlarmActiveMajorType,
|
|
eriAlarmActiveMinorType,
|
|
eriAlarmActiveSpecificProblem,
|
|
eriAlarmActiveLastSequenceNo,
|
|
eriAlarmActiveEventType,
|
|
eriAlarmActiveEventTime,
|
|
eriAlarmActiveProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alarm state with severity major.
|
|
The notification is also used to change severity
|
|
and/or additional text of an alarm. The
|
|
combination of ManagedObject and
|
|
MajorType/MinorType is always unique and can be
|
|
used by management systems to correlate alarm,
|
|
alarm change, and alarm clear. A corresponding
|
|
row will be created in the Alarm Table,
|
|
(eriAlarmActiveAlarmTable). The sequence number
|
|
will increase for every notification and can be
|
|
used to detect lost notifications.
|
|
|
|
A management system should be prepared for
|
|
appending text to additional text, indicated by
|
|
the eriAlarmNObjMoreAdditionalText varbind, and
|
|
sent with eriAlarmAppendInfo. (Note do not
|
|
confuse this with a change of additional text.)
|
|
|
|
A management system should also be prepared to
|
|
receive a resource ID (OID) identifying the
|
|
alarming resource if the system sending the
|
|
notification can provide that information. In
|
|
that case, eriAlarmNObjResourceId will be set to
|
|
'true' and the resource ID will be sent in an
|
|
eriAlarmAppendInfo notification."
|
|
::= { eriAlarmNotifsPrefix 4 }
|
|
|
|
eriAlarmCritical NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmActiveManagedObject,
|
|
eriAlarmActiveMajorType,
|
|
eriAlarmActiveMinorType,
|
|
eriAlarmActiveSpecificProblem,
|
|
eriAlarmActiveLastSequenceNo,
|
|
eriAlarmActiveEventType,
|
|
eriAlarmActiveEventTime,
|
|
eriAlarmActiveProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alarm state with severity critical.
|
|
The notification is also used to change severity
|
|
and/or additional text of an alarm. The
|
|
combination of ManagedObject and
|
|
MajorType/MinorType is always unique and can be
|
|
used by management systems to correlate alarm,
|
|
alarm change, and alarm clear. A corresponding
|
|
row will be created in the Alarm Table,
|
|
(eriAlarmActiveAlarmTable). The sequence number
|
|
will increase for every notification and can be
|
|
used to detect lost notifications.
|
|
|
|
A management system should be prepared for
|
|
appending text to additional text, indicated by
|
|
the eriAlarmNObjMoreAdditionalText varbind, and
|
|
sent with eriAlarmAppendInfo. (Note do not
|
|
confuse this with a change of additional text.)
|
|
|
|
A management system should also be prepared to
|
|
receive a resource ID (OID) identifying the
|
|
alarming resource if the system sending the
|
|
notification can provide that information. In
|
|
that case, eriAlarmNObjResourceId will be set to
|
|
'true' and the resource ID will be sent in an
|
|
eriAlarmAppendInfo notification."
|
|
::= { eriAlarmNotifsPrefix 5 }
|
|
|
|
eriAlarmCleared NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmActiveManagedObject,
|
|
eriAlarmActiveMajorType,
|
|
eriAlarmActiveMinorType,
|
|
eriAlarmActiveSpecificProblem,
|
|
eriAlarmActiveLastSequenceNo,
|
|
eriAlarmActiveEventType,
|
|
eriAlarmActiveEventTime,
|
|
eriAlarmActiveProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a cleared alarm state. The combination
|
|
of ManagedObject and MajorType/MinorType is
|
|
always unique and shall be used by management
|
|
systems to correlate alarm and alarm clear. The
|
|
corresponding row in the alarm table will be
|
|
deleted, (eriAlarmActiveAlarmTable). The
|
|
sequence number will increase for every
|
|
notification and can be used to detect lost
|
|
notifications. A management system should be
|
|
prepared for appending text to additional text,
|
|
indicated by the eriAlarmNObjMoreAdditionalText
|
|
varbind, and sent with eriAlarmAppendInfo.
|
|
(Note do not confuse this with a change of
|
|
additional text).
|
|
|
|
A management system should also be prepared to
|
|
receive a resource ID (OID) identifying the
|
|
alarming resource if the system sending the
|
|
notification can provide that information. In
|
|
that case, eriAlarmNObjResourceId will be set to
|
|
'true' and the resource ID will be sent in an
|
|
eriAlarmAppendInfo notification.
|
|
|
|
A management system should also be prepared to
|
|
receive a resource ID (OID) identifying the
|
|
alarming resource if the system sending the
|
|
notification can provide that information. In
|
|
that case, eriAlarmNObjResourceId will be set to
|
|
'true' and the resource ID will be sent in an
|
|
eriAlarmAppendInfo notification."
|
|
::= { eriAlarmNotifsPrefix 7 }
|
|
|
|
eriAlarmAppendInfo NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmActiveManagedObject,
|
|
eriAlarmActiveMajorType,
|
|
eriAlarmActiveMinorType,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmActiveResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent in order to append
|
|
further info to an existing alarm. It might be
|
|
additional text or a resource ID (OID)
|
|
identifying the alarming resource using an OID.
|
|
If additional text is sent, do not confuse this
|
|
with an actual change of additional text which is
|
|
reported using the eriAlarm<severity>
|
|
notification.
|
|
|
|
A zero-length string value for
|
|
eriAlarmNObjAdditionalText means that no
|
|
additional text is being sent in this
|
|
notification.
|
|
|
|
A null OID (0.0) value for
|
|
eriAlarmActiveResourceId means that no resource
|
|
ID is being sent in this notification."
|
|
::= { eriAlarmNotifsPrefix 8 }
|
|
|
|
--============================
|
|
-- Alerts
|
|
--===============================
|
|
|
|
eriAlarmIndAlert NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmAlertManagedObject,
|
|
eriAlarmAlertMajorType,
|
|
eriAlarmAlertMinorType,
|
|
eriAlarmAlertSpecificProblem,
|
|
eriAlarmAlertLastSequenceNo,
|
|
eriAlarmAlertEventType,
|
|
eriAlarmAlertEventTime,
|
|
eriAlarmAlertProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alert with severity indeterminate.
|
|
A corresponding row will be created in the Alert
|
|
Table. The sequence number will increase for
|
|
every notification and can be used to detect lost
|
|
notifications."
|
|
::= { eriAlarmNotifsPrefix 10 }
|
|
|
|
eriAlarmWarnAlert NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmAlertManagedObject,
|
|
eriAlarmAlertMajorType,
|
|
eriAlarmAlertMinorType,
|
|
eriAlarmAlertSpecificProblem,
|
|
eriAlarmAlertLastSequenceNo,
|
|
eriAlarmAlertEventType,
|
|
eriAlarmAlertEventTime,
|
|
eriAlarmAlertProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alert with severity warning. A
|
|
corresponding row will be created in the Alert
|
|
Table. The sequence number will increase for
|
|
every notification and can be used to detect lost
|
|
notifications."
|
|
::= { eriAlarmNotifsPrefix 11 }
|
|
|
|
eriAlarmMinorAlert NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmAlertManagedObject,
|
|
eriAlarmAlertMajorType,
|
|
eriAlarmAlertMinorType,
|
|
eriAlarmAlertSpecificProblem,
|
|
eriAlarmAlertLastSequenceNo,
|
|
eriAlarmAlertEventType,
|
|
eriAlarmAlertEventTime,
|
|
eriAlarmAlertProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alert with severity minor. A
|
|
corresponding row will be created in the Alert
|
|
Table. The sequence number will increase for
|
|
every notification and can be used to detect lost
|
|
notifications."
|
|
::= { eriAlarmNotifsPrefix 12 }
|
|
|
|
eriAlarmMajorAlert NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmAlertManagedObject,
|
|
eriAlarmAlertMajorType,
|
|
eriAlarmAlertMinorType,
|
|
eriAlarmAlertSpecificProblem,
|
|
eriAlarmAlertLastSequenceNo,
|
|
eriAlarmAlertEventType,
|
|
eriAlarmAlertEventTime,
|
|
eriAlarmAlertProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alert with severity major. A
|
|
corresponding row will be created in the Alert
|
|
Table. The sequence number will increase for
|
|
every notification and can be used to detect lost
|
|
notifications."
|
|
::= { eriAlarmNotifsPrefix 13 }
|
|
|
|
eriAlarmCriticalAlert NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmAlertManagedObject,
|
|
eriAlarmAlertMajorType,
|
|
eriAlarmAlertMinorType,
|
|
eriAlarmAlertSpecificProblem,
|
|
eriAlarmAlertLastSequenceNo,
|
|
eriAlarmAlertEventType,
|
|
eriAlarmAlertEventTime,
|
|
eriAlarmAlertProbableCause,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when a resource
|
|
detects a new alert with severity critical. A
|
|
corresponding row will be created in the Alert
|
|
Table. The sequence number will increase for
|
|
every notification and can be used to detect lost
|
|
notifications."
|
|
::= { eriAlarmNotifsPrefix 14 }
|
|
|
|
eriAlarmAppendAlertInfo NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmAlertManagedObject,
|
|
eriAlarmAlertMajorType,
|
|
eriAlarmAlertMinorType,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmAlertResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent in order to append
|
|
further info to an existing alert. It might be
|
|
additional text or a resource ID (OID)
|
|
identifying the alarming resource using an OID.
|
|
This complements information sent in a previous
|
|
notification.
|
|
|
|
If additional text is sent, do not confuse this
|
|
with an actual change of additional text which is
|
|
reported using the eriAlarmAlert<severity>
|
|
notification.
|
|
|
|
A zero-length string value for
|
|
eriAlarmNObjAdditionalText means that no
|
|
additional text is being sent in this
|
|
notification.
|
|
|
|
A null OID (0.0) value for
|
|
eriAlarmAlertResourceId means that no resource
|
|
ID is being sent in this notification."
|
|
::= { eriAlarmNotifsPrefix 15 }
|
|
|
|
|
|
eriAlarmHeartBeatNotif NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eriAlarmActiveLastSequenceNo,
|
|
eriAlarmAlertLastSequenceNo,
|
|
eriAlarmActiveLastChanged,
|
|
eriAlarmAlertLastChanged
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a heartbeat notification with interval
|
|
according to the eriAlarmHbInterval. It contains
|
|
the last sequence numbers used for alarms and
|
|
alarm events. These varbinds can be used to
|
|
detect lost notifications.
|
|
|
|
The notification eriAlarmHeartBeatNotif will be
|
|
sent every eriAlarmHbInterval. Managers can
|
|
subscribe to the notification using the SNMP
|
|
framework MIBS by using the snmpNotifyName
|
|
'heartbeat'. (SNMP-NOTIFICATION-MIB,
|
|
snmpNotifyTable)."
|
|
::= { eriAlarmNotifsPrefix 20}
|
|
|
|
eriAlarmAlarmListRebuilt NOTIFICATION-TYPE
|
|
OBJECTS { eriAlarmActiveTableURL }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when the active alarm
|
|
list has reached a stable situation after a
|
|
restart or after a system internal audit process.
|
|
It is an indication to the manager to perform a
|
|
alarm resynchronization procedure."
|
|
::= { eriAlarmNotifsPrefix 30}
|
|
|
|
--======================================================================
|
|
-- CONFORMANCE INFORMATION
|
|
--======================================================================
|
|
|
|
eriAlarmCompliances OBJECT IDENTIFIER ::= { eriAlarmConformance 1 }
|
|
|
|
eriAlarmBasicAlarmsCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimal compliance for the Ericsson Alarm MIB.
|
|
Minimal compliance is to support heartbeat,
|
|
active alarm list, and alarm notifications for
|
|
raise and clear."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS
|
|
{
|
|
eriAlarmSummaryGroup,
|
|
eriAlarmActiveAlarmsGroup,
|
|
eriAlarmHeartBeatGroup,
|
|
eriAlarmSimpleAlarmGroup,
|
|
eriAlarmHeartBeatNotifGroup
|
|
}
|
|
GROUP eriAlarmAlertsGroup
|
|
DESCRIPTION "If the system supports history of
|
|
stateless events, alerts."
|
|
GROUP eriAlarmAlertNotifGroup
|
|
DESCRIPTION "If the system supports notifications
|
|
for stateless events, alerts."
|
|
GROUP eriAlarmChangeAlarmGroup
|
|
DESCRIPTION "If the system supports columns in
|
|
the alarm table for original attribute values of
|
|
additional text, severity and event time."
|
|
GROUP eriAlarmAddAddInfoGroup
|
|
DESCRIPTION "If the system supports notifications
|
|
to append text or resource id to existing alarms."
|
|
GROUP eriAlarmSNMPResourceGroup
|
|
DESCRIPTION "If the system supports SNMP Object
|
|
Identifiers to identify managed objects in
|
|
parallel with DNs."
|
|
|
|
OBJECT eriAlarmHbInterval
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required, but is highly
|
|
desirable."
|
|
MODULE SNMP-TARGET-MIB
|
|
MANDATORY-GROUPS {snmpTargetBasicGroup}
|
|
MODULE SNMP-NOTIFICATION-MIB
|
|
MANDATORY-GROUPS {snmpNotifyGroup}
|
|
::= {eriAlarmCompliances 1}
|
|
|
|
eriAlarmGroups OBJECT IDENTIFIER ::= { eriAlarmConformance 2 }
|
|
|
|
eriAlarmSummaryGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eriAlarmSumIndeterminate,
|
|
eriAlarmSumCritical,
|
|
eriAlarmSumMajor,
|
|
eriAlarmSumMinor,
|
|
eriAlarmSumWarning
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group containing the summary counters for alarms."
|
|
::= { eriAlarmGroups 1 }
|
|
|
|
eriAlarmActiveAlarmsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eriAlarmActiveNumber,
|
|
eriAlarmActiveLastChanged,
|
|
eriAlarmActiveLastSequenceNo,
|
|
eriAlarmActiveTableURL,
|
|
eriAlarmActiveMajorType,
|
|
eriAlarmActiveMinorType,
|
|
eriAlarmActiveSpecificProblem,
|
|
eriAlarmActiveManagedObject,
|
|
eriAlarmActiveEventType,
|
|
eriAlarmActiveEventTime,
|
|
eriAlarmActiveProbableCause,
|
|
eriAlarmActiveSeverity,
|
|
eriAlarmActiveAdditionalText,
|
|
eriAlarmNObjAdditionalText,
|
|
eriAlarmNObjResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects needed to support the
|
|
active alarm list."
|
|
::= { eriAlarmGroups 2 }
|
|
|
|
eriAlarmAlertsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eriAlarmAlertNumber,
|
|
eriAlarmAlertLastChanged,
|
|
eriAlarmAlertLastSequenceNo,
|
|
eriAlarmAlertTableURL,
|
|
eriAlarmAlertMajorType,
|
|
eriAlarmAlertMinorType,
|
|
eriAlarmAlertSpecificProblem,
|
|
eriAlarmAlertManagedObject,
|
|
eriAlarmAlertEventType,
|
|
eriAlarmAlertEventTime,
|
|
eriAlarmAlertProbableCause,
|
|
eriAlarmAlertSeverity,
|
|
eriAlarmAlertAdditionalText
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects needed to support the alert
|
|
history."
|
|
::= { eriAlarmGroups 3 }
|
|
|
|
eriAlarmHeartBeatGroup OBJECT-GROUP
|
|
OBJECTS {eriAlarmHbInterval}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Only read is required for compliance"
|
|
::= { eriAlarmGroups 4 }
|
|
|
|
eriAlarmSNMPResourceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eriAlarmActiveResourceId,
|
|
eriAlarmAlertResourceId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects that support SNMP object identifiers for
|
|
resource identification."
|
|
::= { eriAlarmGroups 5 }
|
|
|
|
eriAlarmChangeAlarmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eriAlarmActiveOriginalEventTime,
|
|
eriAlarmActiveOriginalSeverity,
|
|
eriAlarmActiveOrigAdditionalText,
|
|
eriAlarmNObjMoreAdditionalText
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Objects that stores previous state of an alarm."
|
|
::= { eriAlarmGroups 6 }
|
|
|
|
eriAlarmSimpleAlarmGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
eriAlarmIndeterminate,
|
|
eriAlarmWarning,
|
|
eriAlarmMinor,
|
|
eriAlarmMajor,
|
|
eriAlarmCritical,
|
|
eriAlarmCleared,
|
|
eriAlarmAlarmListRebuilt
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notifications in this MIB module."
|
|
::= { eriAlarmGroups 10 }
|
|
|
|
eriAlarmAddAddInfoGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
eriAlarmAppendInfo,
|
|
eriAlarmAppendAlertInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification to support appending of additional text."
|
|
::= { eriAlarmGroups 12 }
|
|
|
|
eriAlarmAlertNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
eriAlarmIndAlert,
|
|
eriAlarmWarnAlert,
|
|
eriAlarmMinorAlert,
|
|
eriAlarmMajorAlert,
|
|
eriAlarmCriticalAlert
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications for stateless alarms"
|
|
::= { eriAlarmGroups 13 }
|
|
|
|
eriAlarmHeartBeatNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {eriAlarmHeartBeatNotif}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Heartbeat notifications."
|
|
::= { eriAlarmGroups 14 }
|
|
|
|
--======================================================================
|
|
-- COMPLIANCE STATEMENTS
|
|
--======================================================================
|
|
|
|
END --this file
|