2005 lines
50 KiB
Plaintext
2005 lines
50 KiB
Plaintext
-- *****************************************************************
|
||
-- EKINOPS-Pmops2d.TXT: MIB
|
||
--
|
||
--MIB Part Number:3MI00307AAAA
|
||
--MIB Version:05
|
||
--
|
||
-- Copyright (c) 2014 by Ekinops
|
||
-- All rights reserved.
|
||
--
|
||
-- *****************************************************************
|
||
|
||
EKINOPS-Pmops2d-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
ekinops,
|
||
EkiState,
|
||
EkiOnOff,
|
||
EkiMode,
|
||
EkiProtocol,
|
||
EkiApiState,
|
||
EkiSynchroMode,
|
||
EkiMeasureType
|
||
FROM EKINOPS-MIB
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Unsigned32,
|
||
Integer32,
|
||
Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION,
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
modulePmops2d MODULE-IDENTITY
|
||
LAST-UPDATED "201605230000Z"
|
||
ORGANIZATION "Ekinops"
|
||
CONTACT-INFO
|
||
"Ekinops
|
||
|
||
3, rue Blaise Pascal
|
||
F-22300 Lannion / FRANCE
|
||
|
||
Tel : +33 (0)2 96 05 00 30
|
||
Fax : +33 (0)2 96 48 62 39
|
||
|
||
E-mail: support@ekinops.net"
|
||
DESCRIPTION
|
||
"MIB for the Ekinops Pmops2d hardware."
|
||
REVISION "201506250000Z"
|
||
DESCRIPTION
|
||
"Initial Version."
|
||
|
||
REVISION "201506250000Z"
|
||
DESCRIPTION
|
||
"Creation for PMOPS2D"
|
||
REVISION "201603040000Z"
|
||
DESCRIPTION
|
||
"Creation"
|
||
REVISION "201605230000Z"
|
||
DESCRIPTION
|
||
"New AlarmType – synthesisAlarm (12)"
|
||
::= { ekinops 71 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF LEVEL 2
|
||
--- *****************************************************
|
||
|
||
|
||
pmops2dalarms OBJECT IDENTIFIER ::= { modulePmops2d 2 }
|
||
|
||
pmops2dAlmOther OBJECT IDENTIFIER ::= { pmops2dalarms 1 }
|
||
pmops2dAlmOtherNurg OBJECT IDENTIFIER ::= { pmops2dAlmOther 1 }
|
||
pmops2dAlmOtherUrg OBJECT IDENTIFIER ::= { pmops2dAlmOther 2 }
|
||
pmops2dAlmOtherCrit OBJECT IDENTIFIER ::= { pmops2dAlmOther 3 }
|
||
|
||
pmops2dAlmClient OBJECT IDENTIFIER ::= { pmops2dalarms 2 }
|
||
pmops2dAlmClientNurg OBJECT IDENTIFIER ::= { pmops2dAlmClient 1 }
|
||
pmops2dAlmClientUrg OBJECT IDENTIFIER ::= { pmops2dAlmClient 2 }
|
||
pmops2dAlmClientCrit OBJECT IDENTIFIER ::= { pmops2dAlmClient 3 }
|
||
|
||
pmops2dAlmLine OBJECT IDENTIFIER ::= { pmops2dalarms 3 }
|
||
pmops2dAlmLineNurg OBJECT IDENTIFIER ::= { pmops2dAlmLine 1 }
|
||
pmops2dAlmLineUrg OBJECT IDENTIFIER ::= { pmops2dAlmLine 2 }
|
||
pmops2dAlmLineCrit OBJECT IDENTIFIER ::= { pmops2dAlmLine 3 }
|
||
|
||
|
||
pmops2dmeasures OBJECT IDENTIFIER ::= { modulePmops2d 3 }
|
||
pmops2dMesrOther OBJECT IDENTIFIER ::= { pmops2dmeasures 1 }
|
||
pmops2dMesrClient OBJECT IDENTIFIER ::= { pmops2dmeasures 2 }
|
||
pmops2dMesrLine OBJECT IDENTIFIER ::= { pmops2dmeasures 3 }
|
||
|
||
|
||
pmops2dcontrolsWrite OBJECT IDENTIFIER ::= { modulePmops2d 6 }
|
||
pmops2dCtrlOther OBJECT IDENTIFIER ::= { pmops2dcontrolsWrite 1 }
|
||
pmops2dCtrlClient OBJECT IDENTIFIER ::= { pmops2dcontrolsWrite 2 }
|
||
pmops2dCtrlLine OBJECT IDENTIFIER ::= { pmops2dcontrolsWrite 3 }
|
||
|
||
pmops2dri OBJECT IDENTIFIER ::= { modulePmops2d 7 }
|
||
pmops2driTable OBJECT IDENTIFIER ::= { pmops2dri 1 }
|
||
|
||
|
||
pmops2dConfig OBJECT IDENTIFIER ::= { modulePmops2d 9 }
|
||
|
||
pmops2dtraps OBJECT IDENTIFIER ::= { modulePmops2d 10 }
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- TEXTUAL-CONVENTION
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
Pmops2dSwitchMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "different switch mode for port"
|
||
SYNTAX INTEGER {
|
||
switchManual1(1),
|
||
switchManual2(2),
|
||
switchAuto(4),
|
||
switchAutoRevertive(8)
|
||
}
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- REMOTE INVENTORY
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
pmops2dRinvReloadInventory OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reload the inventory: This OID triggers an
|
||
inventory reload."
|
||
::= { pmops2dri 2 }
|
||
|
||
pmops2dRinvHwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"HW platform description: This OID contains the
|
||
description of the Hardware platform."
|
||
::= { pmops2dri 3 }
|
||
|
||
pmops2dRinvModulePlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Module platform description: This OID contains the
|
||
description of the Module."
|
||
::= { pmops2dri 4 }
|
||
|
||
pmops2dRinvSwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SW platform description: This OID contains the
|
||
description of the Software platform."
|
||
::= { pmops2dri 5 }
|
||
|
||
|
||
|
||
--- Clients INV
|
||
|
||
pmops2dRinvSfpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dRinvSfpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the clients on the selected module"
|
||
::= { pmops2driTable 1 }
|
||
|
||
pmops2dRinvSfpEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dRinvSfpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the client table"
|
||
INDEX { pmops2dRinvSfpIndex }
|
||
::= { pmops2dRinvSfpTable 1 }
|
||
|
||
|
||
|
||
Pmops2dRinvSfpEntry::=
|
||
SEQUENCE {
|
||
pmops2dRinvSfpIndex
|
||
Integer32,
|
||
pmops2dRinvSfp
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmops2dRinvSfpIndex OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for Sfp table"
|
||
::= { pmops2dRinvSfpEntry 1 }
|
||
|
||
|
||
pmops2dRinvSfp OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the Clients: This OID contains the inventory for the clients"
|
||
::= { pmops2dRinvSfpEntry 2 }
|
||
|
||
|
||
|
||
--- Lines INV
|
||
|
||
pmops2dRinvLineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dRinvLineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the lines on the selected module"
|
||
::= { pmops2driTable 2 }
|
||
|
||
pmops2dRinvLineEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dRinvLineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the line table"
|
||
INDEX { pmops2dRinvLineIndex }
|
||
::= { pmops2dRinvLineTable 1 }
|
||
|
||
|
||
|
||
Pmops2dRinvLineEntry::=
|
||
SEQUENCE {
|
||
pmops2dRinvLineIndex
|
||
Integer32,
|
||
pmops2dRinvLine
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmops2dRinvLineIndex OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for line table"
|
||
::= { pmops2dRinvLineEntry 1 }
|
||
|
||
|
||
pmops2dRinvLine OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the lines: This OID contains the inventory for the lines"
|
||
::= { pmops2dRinvLineEntry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- ALARMS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm0 article
|
||
--- *****************************************************
|
||
pmops2dAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmops2dAlmOtherCrit 0 }
|
||
|
||
|
||
|
||
|
||
pmops2dAlmDefFuseB OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse B Fail :This OID indicates
|
||
that the fuse of the power input
|
||
B is in fail condition <Help>
|
||
Status of the Fuse B <Condtype>
|
||
DEF_FUSE_B <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmsynthAlm0 16 }
|
||
|
||
|
||
|
||
pmops2dAlmDefFuseA OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse A Fail :This OID indicates
|
||
that the fuse of the power input
|
||
A is in fail condition <Help>
|
||
Status of the Fuse A <Condtype>
|
||
DEF_FUSE_A <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmsynthAlm0 15 }
|
||
|
||
|
||
|
||
pmops2dAlmModuleGlobFailure OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Failure :This OID is set
|
||
on detection of a failure originating
|
||
from the PM <Condtype> MODULE_GLOB_FAILURE
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmsynthAlm0 9 }
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pmops2dAlmsynthClientAlm articles
|
||
--- *********************************************************
|
||
|
||
pmops2dAlmsynthClientAlmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dAlmsynthClientAlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pmops2dAlmsynthClientAlm
|
||
Article
|
||
"
|
||
::= { pmops2dAlmClientCrit 8 }
|
||
|
||
|
||
pmops2dAlmsynthClientAlmEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dAlmsynthClientAlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pmops2dAlmsynthClientAlm
|
||
table
|
||
"
|
||
INDEX { pmops2dAlmsynthClientAlmIndex }
|
||
::= { pmops2dAlmsynthClientAlmTable 1 }
|
||
|
||
|
||
Pmops2dAlmsynthClientAlmEntry ::=
|
||
SEQUENCE {
|
||
pmops2dAlmsynthClientAlmIndex
|
||
INTEGER,
|
||
pmops2dAlmClientFailAccPortn
|
||
EkiOnOff,
|
||
pmops2dAlmClientHwFailAccPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pmops2dAlmsynthClientAlmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pmops2dAlmsynthClientAlm
|
||
table
|
||
"
|
||
::= { pmops2dAlmsynthClientAlmEntry 1 }
|
||
|
||
|
||
pmops2dAlmClientFailAccPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Client_Acc_Fail :This OID indicates
|
||
a client failure on the OPS <Help>
|
||
This alarm indicates if a client
|
||
fail access Alarm has been detected
|
||
on the OPS <Condtype> CLIENT_FAIL_ACC
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmsynthClientAlmEntry 13 }
|
||
|
||
|
||
pmops2dAlmClientHwFailAccPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
HW_Fail_Acc :This OID indicates
|
||
a client hardware failure on the
|
||
OPS <Help> This alarm indicates
|
||
if a client HW fail access Alarm
|
||
has been detected on the OPS <Condtype>
|
||
CLIENT_HW_FAIL_ACC <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmops2dAlmsynthClientAlmEntry 5 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pmops2dAlmsynthLineAlm articles
|
||
--- *********************************************************
|
||
|
||
pmops2dAlmsynthLineAlmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dAlmsynthLineAlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pmops2dAlmsynthLineAlm
|
||
Article
|
||
"
|
||
::= { pmops2dAlmLineCrit 16 }
|
||
|
||
|
||
pmops2dAlmsynthLineAlmEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dAlmsynthLineAlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pmops2dAlmsynthLineAlm
|
||
table
|
||
"
|
||
INDEX { pmops2dAlmsynthLineAlmIndex }
|
||
::= { pmops2dAlmsynthLineAlmTable 1 }
|
||
|
||
|
||
Pmops2dAlmsynthLineAlmEntry ::=
|
||
SEQUENCE {
|
||
pmops2dAlmsynthLineAlmIndex
|
||
INTEGER,
|
||
pmops2dAlmLineFailAccPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineMeasAlmPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineMeasWngPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineHwFailAccPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pmops2dAlmsynthLineAlmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pmops2dAlmsynthLineAlm
|
||
table
|
||
"
|
||
::= { pmops2dAlmsynthLineAlmEntry 1 }
|
||
|
||
|
||
pmops2dAlmLineFailAccPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line_Acc_Fail :This OID indicates
|
||
a line failure on the OPS <Help>
|
||
This alarm indicates if a line
|
||
fail access Alarm has been detected
|
||
on the OPS <Condtype> LINE_FAIL_ACC
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmsynthLineAlmEntry 13 }
|
||
|
||
|
||
pmops2dAlmLineMeasAlmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Measure Alarm :This OID indicates
|
||
an line alarm is present coming
|
||
out of OPS diagnostic monitoring
|
||
<Help> This alarm indicates if
|
||
a line diagnostic monitoring Alarm
|
||
has been detected on the OPS <Condtype>
|
||
LINE_MEAS_ALM <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmsynthLineAlmEntry 11 }
|
||
|
||
|
||
pmops2dAlmLineMeasWngPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Measure Warning :This OID indicates
|
||
a line warning is present coming
|
||
out of OPS diagnostic monitoring
|
||
<Help> This alarm indicates if
|
||
a line diagnostic monitoring Warning
|
||
has been detected on the OPS <Condtype>
|
||
LINE_MEAS_WNG <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmsynthLineAlmEntry 10 }
|
||
|
||
|
||
pmops2dAlmLineHwFailAccPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
HW_Fail_Acc :This OID indicates
|
||
a line hardware failure on the
|
||
OPS <Help> This alarm indicates
|
||
if a line HW fail access Alarm
|
||
has been detected on the OPS <Condtype>
|
||
LINE_HW_FAIL_ACC <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmsynthLineAlmEntry 5 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pmops2dAlmclientComAlarm articles
|
||
--- *********************************************************
|
||
|
||
pmops2dAlmclientComAlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dAlmclientComAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pmops2dAlmclientComAlarm
|
||
Article
|
||
"
|
||
::= { pmops2dAlmClientUrg 24 }
|
||
|
||
|
||
pmops2dAlmclientComAlarmEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dAlmclientComAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pmops2dAlmclientComAlarm
|
||
table
|
||
"
|
||
INDEX { pmops2dAlmclientComAlarmIndex }
|
||
::= { pmops2dAlmclientComAlarmTable 1 }
|
||
|
||
|
||
Pmops2dAlmclientComAlarmEntry ::=
|
||
SEQUENCE {
|
||
pmops2dAlmclientComAlarmIndex
|
||
INTEGER,
|
||
pmops2dAlmClientComSwitchFailPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pmops2dAlmclientComAlarmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pmops2dAlmclientComAlarm
|
||
table
|
||
"
|
||
::= { pmops2dAlmclientComAlarmEntry 1 }
|
||
|
||
|
||
pmops2dAlmClientComSwitchFailPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Switch Fail :This OID indicates
|
||
the OPS A switch component in in
|
||
fail condition <Help> This alarm
|
||
indicates if the OPS switch is
|
||
in fail condition <Condtype> CLIENT_COM_SWITCH_FAIL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmclientComAlarmEntry 9 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pmops2dAlmlineAlarm articles
|
||
--- *********************************************************
|
||
|
||
pmops2dAlmlineAlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dAlmlineAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pmops2dAlmlineAlarm Article
|
||
"
|
||
::= { pmops2dAlmLineUrg 32 }
|
||
|
||
|
||
pmops2dAlmlineAlarmEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dAlmlineAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pmops2dAlmlineAlarm
|
||
table
|
||
"
|
||
INDEX { pmops2dAlmlineAlarmIndex }
|
||
::= { pmops2dAlmlineAlarmTable 1 }
|
||
|
||
|
||
Pmops2dAlmlineAlarmEntry ::=
|
||
SEQUENCE {
|
||
pmops2dAlmlineAlarmIndex
|
||
INTEGER,
|
||
pmops2dAlmSwitchPositionTwoPortn
|
||
EkiOnOff,
|
||
pmops2dAlmSwitchPositionOnePortn
|
||
EkiOnOff,
|
||
pmops2dAlmLosTxPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLosRxPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pmops2dAlmlineAlarmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pmops2dAlmlineAlarm
|
||
table
|
||
"
|
||
::= { pmops2dAlmlineAlarmEntry 1 }
|
||
|
||
|
||
pmops2dAlmSwitchPositionTwoPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
RX2 Selected :This OID indicates
|
||
the OPS selects the RX 2 input
|
||
<Help> This status indicates
|
||
if the RX2 input is selected on
|
||
the OPS <Condtype> SWITCH_POSITION_TWO
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineAlarmEntry 7 }
|
||
|
||
|
||
pmops2dAlmSwitchPositionOnePortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
RX1 Selected :This OID indicates
|
||
the OPS selects the RX 1 input
|
||
<Help> This status indicates
|
||
if the RX 1 input is selected on
|
||
the OPS <Condtype> SWITCH_POSITION_ONE
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineAlarmEntry 6 }
|
||
|
||
|
||
pmops2dAlmLosTxPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TX Loss Of Signal :This OID indicates
|
||
that a LOS is detected on the Transmit
|
||
of the OPS <Help> This alarm
|
||
indicates if an optical signal
|
||
is detected on the TX of the OPS
|
||
<Condtype> LOS_TX <Probcause> transmitFailure
|
||
(55) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineAlarmEntry 4 }
|
||
|
||
|
||
pmops2dAlmLosRxPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
RX Loss Of Signal :This OID indicates
|
||
that a LOS is detected on the Receive
|
||
1 of the OPS <Help> This alarm
|
||
indicates if an optical signal
|
||
is detected on the RX of the OPS
|
||
<Condtype> LOS_RX <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineAlarmEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pmops2dAlmlineMeasAla articles
|
||
--- *********************************************************
|
||
|
||
pmops2dAlmlineMeasAlaTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dAlmlineMeasAlaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pmops2dAlmlineMeasAla
|
||
Article
|
||
"
|
||
::= { pmops2dAlmLineUrg 40 }
|
||
|
||
|
||
pmops2dAlmlineMeasAlaEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dAlmlineMeasAlaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pmops2dAlmlineMeasAla
|
||
table
|
||
"
|
||
INDEX { pmops2dAlmlineMeasAlaIndex }
|
||
::= { pmops2dAlmlineMeasAlaTable 1 }
|
||
|
||
|
||
Pmops2dAlmlineMeasAlaEntry ::=
|
||
SEQUENCE {
|
||
pmops2dAlmlineMeasAlaIndex
|
||
INTEGER,
|
||
pmops2dAlmLineRxPwrHighAlaPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineRxPwrLowAlaPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineTxPwrHighAlaPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineTxPwrLowAlaPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pmops2dAlmlineMeasAlaIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pmops2dAlmlineMeasAla
|
||
table
|
||
"
|
||
::= { pmops2dAlmlineMeasAlaEntry 1 }
|
||
|
||
|
||
pmops2dAlmLineRxPwrHighAlaPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Rx High Alarm : This OID indicates
|
||
that Receive power of the OPS is
|
||
higher than the alarm threshold
|
||
of the OPS <Help> This alarm
|
||
indicates if the receive power
|
||
on the receive side of the OPS
|
||
is too high <Condtype> LINE_RX_PWR_HIGH_ALA
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineMeasAlaEntry 5 }
|
||
|
||
|
||
pmops2dAlmLineRxPwrLowAlaPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Rx Low Alarm :This OID indicates
|
||
that Receive power or the OPS is
|
||
lower than the alarm threshold
|
||
of the OPS <Help> This alarm
|
||
indicates if the receive power
|
||
on the receive side of the OPS
|
||
is too low <Condtype> LINE_RX_PWR_LOW_ALA
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineMeasAlaEntry 4 }
|
||
|
||
|
||
pmops2dAlmLineTxPwrHighAlaPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Tx High Alarm : This OID indicates
|
||
that Transmit power or the OPS
|
||
is higher than the alarm threshold
|
||
of the OPS <Help> This alarm
|
||
indicates if the receive power
|
||
on the transmit side of the OPS
|
||
is too high <Condtype> LINE_TX_PWR_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineMeasAlaEntry 3 }
|
||
|
||
|
||
pmops2dAlmLineTxPwrLowAlaPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Tx Low Alarm :This OID indicates
|
||
that Transmit power or the OPS
|
||
is lower than the alarm threshold
|
||
of the OPS <Help> This alarm
|
||
indicates if the receive power
|
||
on the transmit side of the OPS
|
||
is too low <Condtype> LINE_TX_PWR_LOW_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineMeasAlaEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pmops2dAlmlineMeasWng articles
|
||
--- *********************************************************
|
||
|
||
pmops2dAlmlineMeasWngTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dAlmlineMeasWngEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pmops2dAlmlineMeasWng
|
||
Article
|
||
"
|
||
::= { pmops2dAlmLineNurg 48 }
|
||
|
||
|
||
pmops2dAlmlineMeasWngEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dAlmlineMeasWngEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pmops2dAlmlineMeasWng
|
||
table
|
||
"
|
||
INDEX { pmops2dAlmlineMeasWngIndex }
|
||
::= { pmops2dAlmlineMeasWngTable 1 }
|
||
|
||
|
||
Pmops2dAlmlineMeasWngEntry ::=
|
||
SEQUENCE {
|
||
pmops2dAlmlineMeasWngIndex
|
||
INTEGER,
|
||
pmops2dAlmLineRxPwrHighWngPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineRxPwrLowWngPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineTxPwrHighWngPortn
|
||
EkiOnOff,
|
||
pmops2dAlmLineTxPwrLowWngPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pmops2dAlmlineMeasWngIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pmops2dAlmlineMeasWng
|
||
table
|
||
"
|
||
::= { pmops2dAlmlineMeasWngEntry 1 }
|
||
|
||
|
||
pmops2dAlmLineRxPwrHighWngPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Rx High Warning : This OID indicates
|
||
that Receive power or the OPS is
|
||
higher than the warning threshold
|
||
of the OPS <Help> This warning
|
||
indicates if the receive power
|
||
on the receive side of the OPS
|
||
is too high <Condtype> LINE_RX_PWR_HIGH_WNG
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineMeasWngEntry 5 }
|
||
|
||
|
||
pmops2dAlmLineRxPwrLowWngPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Rx Low Warning :This OID indicates
|
||
that Receive power or the OPS is
|
||
lower than the warning threshold
|
||
of the OPS <Help> This warning
|
||
indicates if the receive power
|
||
on the receive side of the OPS
|
||
is too low <Condtype> LINE_RX_PWR_LOW_WNG
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineMeasWngEntry 4 }
|
||
|
||
|
||
pmops2dAlmLineTxPwrHighWngPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Tx High Warning : This OID indicates
|
||
that Transmit power or the OPS
|
||
is higher than the warning threshold
|
||
of the OPS <Help> This warning
|
||
indicates if the receive power
|
||
on the transmit side of the OPS
|
||
is too high <Condtype> LINE_TX_PWR_HIGH_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineMeasWngEntry 3 }
|
||
|
||
|
||
pmops2dAlmLineTxPwrLowWngPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Tx Low Warning :This OID indicates
|
||
that Transmit power or the OPS
|
||
is lower than the warning threshold
|
||
of the OPS <Help> This warning
|
||
indicates if the receive power
|
||
on the transmit side of the OPS
|
||
is too low <Condtype> LINE_TX_PWR_LOW_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmlineMeasWngEntry 2 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the switchOutOfService article
|
||
--- *****************************************************
|
||
pmops2dAlmswitchOutOfService OBJECT IDENTIFIER ::= { pmops2dAlmOtherNurg 64 }
|
||
|
||
|
||
|
||
|
||
pmops2dAlmOpsbOutofservice OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OPS B Out Of Service :This OID
|
||
indicates that the OPSB is In Service
|
||
(1) of Out or Service (2). <Help>
|
||
This status indicates if the OPS
|
||
is in service <Condtype> OPSB_OUTOFSERVICE
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmswitchOutOfService 2 }
|
||
|
||
|
||
|
||
pmops2dAlmOpsaOutofservice OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OPS A Out Of Service :This OID
|
||
indicates that the OPSA is In Service
|
||
(1) of Out or Service (2). <Help>
|
||
This status indicates if the OPS
|
||
is in service <Condtype> OPSA_OUTOFSERVICE
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmops2dAlmswitchOutOfService 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONTROLS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth0 article
|
||
--- *****************************************************
|
||
pmops2dCtrlsynth0 OBJECT IDENTIFIER ::= { pmops2dCtrlOther 0 }
|
||
|
||
|
||
|
||
|
||
pmops2dCtrlConfClear OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Clear Configuration Tables :This
|
||
bit clears the configuration tables
|
||
from configuration in the flash.
|
||
<Help> This control restores
|
||
the default configuration of the
|
||
module
|
||
"
|
||
::= { pmops2dCtrlsynth0 13 }
|
||
|
||
|
||
|
||
pmops2dCtrlConfFlash OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Write Configuration Tables :This
|
||
bit saves the current configuration
|
||
of the module as configuration
|
||
in the flash. <Help> This control
|
||
saves the customer configuration
|
||
on the module
|
||
"
|
||
::= { pmops2dCtrlsynth0 9 }
|
||
|
||
|
||
|
||
pmops2dCtrlConfLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables :When
|
||
set this enables loading from flash
|
||
configuration1 into the module.
|
||
"
|
||
::= { pmops2dCtrlsynth0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth4 article
|
||
--- *****************************************************
|
||
pmops2dCtrlsynth4 OBJECT IDENTIFIER ::= { pmops2dCtrlOther 4 }
|
||
|
||
|
||
|
||
|
||
pmops2dCtrlCorrelatOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Disable Alarm Correlation :This
|
||
OID disables the alarm correlation
|
||
in the PM.
|
||
"
|
||
::= { pmops2dCtrlsynth4 2 }
|
||
|
||
|
||
|
||
pmops2dCtrlCorrelatOn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Enable Alarm Correlation :This
|
||
OID enables the alarm correlation
|
||
in the PM.
|
||
"
|
||
::= { pmops2dCtrlsynth4 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swMgnt article
|
||
--- *****************************************************
|
||
pmops2dCtrlswMgnt OBJECT IDENTIFIER ::= { pmops2dCtrlOther 5 }
|
||
|
||
|
||
|
||
|
||
pmops2dCtrlWarmReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Warm Reset :This OID, when
|
||
set, causes a warm reset of the
|
||
Software. This reset is not traffic
|
||
affecting, and the configuration
|
||
of the Sofwtare remains unchanged.
|
||
<Help> This control initiates
|
||
a warm reset of the module.
|
||
"
|
||
::= { pmops2dCtrlswMgnt 3 }
|
||
|
||
|
||
|
||
pmops2dCtrlColdReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Cold Reset :This OID, when
|
||
set, causes a cold reset of the
|
||
Software. This reset is traffic
|
||
affecting, and the configuration
|
||
of Software is reloaded on start-up.
|
||
<Help> This control initiates
|
||
a cold reset of the module.
|
||
"
|
||
::= { pmops2dCtrlswMgnt 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the ledTest article
|
||
--- *****************************************************
|
||
pmops2dCtrlledTest OBJECT IDENTIFIER ::= { pmops2dCtrlOther 64 }
|
||
|
||
|
||
|
||
|
||
pmops2dCtrlLedOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Leds Off :This OID switches off
|
||
all the Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to OFF
|
||
"
|
||
::= { pmops2dCtrlledTest 3 }
|
||
|
||
|
||
|
||
pmops2dCtrlRedLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Red Leds Test :This OID switches
|
||
on all the red Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to red
|
||
"
|
||
::= { pmops2dCtrlledTest 2 }
|
||
|
||
|
||
|
||
pmops2dCtrlGreenLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Green Leds Test :This OID switches
|
||
on all the green Leds as a test
|
||
feature. <Help> This control
|
||
initiates a test leds turning
|
||
all the LEDs to green
|
||
"
|
||
::= { pmops2dCtrlledTest 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- MEASURES
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pmops2dMesrtxPower articles
|
||
--- *********************************************************
|
||
|
||
pmops2dMesrtxPowerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dMesrtxPowerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pmops2dMesrtxPower Article
|
||
"
|
||
::= { pmops2dMesrLine 16 }
|
||
|
||
|
||
pmops2dMesrtxPowerEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dMesrtxPowerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pmops2dMesrtxPower
|
||
table
|
||
"
|
||
INDEX { pmops2dMesrtxPowerIndex }
|
||
::= { pmops2dMesrtxPowerTable 1 }
|
||
|
||
|
||
Pmops2dMesrtxPowerEntry ::=
|
||
SEQUENCE {
|
||
pmops2dMesrtxPowerIndex
|
||
INTEGER,
|
||
pmops2dMesrtxPowerPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pmops2dMesrtxPowerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pmops2dMesrtxPower
|
||
table
|
||
"
|
||
::= { pmops2dMesrtxPowerEntry 1 }
|
||
|
||
|
||
pmops2dMesrtxPowerPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TX Power :This OID gives the transmit
|
||
power value of the signal , read
|
||
on the coupler output (Power=(AV-32768)*0.005)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Transmit optical power
|
||
on the TX of the OPS
|
||
"
|
||
::= { pmops2dMesrtxPowerEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pmops2dMesrrxPower articles
|
||
--- *********************************************************
|
||
|
||
pmops2dMesrrxPowerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dMesrrxPowerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pmops2dMesrrxPower Article
|
||
"
|
||
::= { pmops2dMesrLine 24 }
|
||
|
||
|
||
pmops2dMesrrxPowerEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dMesrrxPowerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pmops2dMesrrxPower
|
||
table
|
||
"
|
||
INDEX { pmops2dMesrrxPowerIndex }
|
||
::= { pmops2dMesrrxPowerTable 1 }
|
||
|
||
|
||
Pmops2dMesrrxPowerEntry ::=
|
||
SEQUENCE {
|
||
pmops2dMesrrxPowerIndex
|
||
INTEGER,
|
||
pmops2dMesrrxPowerPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pmops2dMesrrxPowerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pmops2dMesrrxPower
|
||
table
|
||
"
|
||
::= { pmops2dMesrrxPowerEntry 1 }
|
||
|
||
|
||
pmops2dMesrrxPowerPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
RX Power :This OID gives the receive
|
||
power value of the signal , read
|
||
on the switch input (Power=(AV-32768)*0.005)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Receive optical power
|
||
on the RX of the OPS
|
||
"
|
||
::= { pmops2dMesrrxPowerEntry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONFIG
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group accessCAisCsf
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgAccessCAisCsf OBJECT IDENTIFIER ::= { pmops2dConfig 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgClientcaiscsfTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dCfgClientcaiscsfEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmops2dCfgAccessCAisCsf 1 }
|
||
|
||
|
||
pmops2dCfgClientcaiscsfEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dCfgClientcaiscsfEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the accessCAisCsf
|
||
table
|
||
"
|
||
INDEX { pmops2dCfgClientcaiscsfIndex }
|
||
::= { pmops2dCfgClientcaiscsfTable 1 }
|
||
|
||
|
||
Pmops2dCfgClientcaiscsfEntry ::=
|
||
SEQUENCE {
|
||
pmops2dCfgClientcaiscsfIndex
|
||
INTEGER,
|
||
pmops2dCfgReservedPortn
|
||
Unsigned32
|
||
}
|
||
|
||
|
||
pmops2dCfgClientcaiscsfIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the clientcaiscsf
|
||
table
|
||
"
|
||
::= { pmops2dCfgClientcaiscsfEntry 1 }
|
||
|
||
|
||
pmops2dCfgReservedPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
:
|
||
"
|
||
::= { pmops2dCfgClientcaiscsfEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group startUp
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgStartUp OBJECT IDENTIFIER ::= { pmops2dConfig 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2111
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgClientStartupTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dCfgClientStartupEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmops2dCfgStartUp 1 }
|
||
|
||
|
||
pmops2dCfgClientStartupEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dCfgClientStartupEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the startUp
|
||
table
|
||
"
|
||
INDEX { pmops2dCfgClientStartupIndex }
|
||
::= { pmops2dCfgClientStartupTable 1 }
|
||
|
||
|
||
Pmops2dCfgClientStartupEntry ::=
|
||
SEQUENCE {
|
||
pmops2dCfgClientStartupIndex
|
||
INTEGER,
|
||
pmops2dCfgClientSwitchModePortn
|
||
Unsigned32
|
||
}
|
||
|
||
|
||
pmops2dCfgClientStartupIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the clientStartup
|
||
table
|
||
"
|
||
::= { pmops2dCfgClientStartupEntry 1 }
|
||
|
||
|
||
pmops2dCfgClientSwitchModePortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default setting on OPS switch
|
||
:This register configures the
|
||
default switch mode
|
||
"
|
||
::= { pmops2dCfgClientStartupEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2191
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgLineStartupThreshTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dCfgLineStartupThreshEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmops2dCfgStartUp 2 }
|
||
|
||
|
||
pmops2dCfgLineStartupThreshEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dCfgLineStartupThreshEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the startUp
|
||
table
|
||
"
|
||
INDEX { pmops2dCfgLineStartupThreshIndex }
|
||
::= { pmops2dCfgLineStartupThreshTable 1 }
|
||
|
||
|
||
Pmops2dCfgLineStartupThreshEntry ::=
|
||
SEQUENCE {
|
||
pmops2dCfgLineStartupThreshIndex
|
||
INTEGER,
|
||
pmops2dCfgLineRxPwrSettingPortn
|
||
Unsigned32
|
||
}
|
||
|
||
|
||
pmops2dCfgLineStartupThreshIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the lineStartupThresh
|
||
table
|
||
"
|
||
::= { pmops2dCfgLineStartupThreshEntry 1 }
|
||
|
||
|
||
pmops2dCfgLineRxPwrSettingPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default setting on OPS Rx Pwr
|
||
:This register configures the
|
||
default RX1 Loss threshold on
|
||
the OPS B (Unit = dBm)
|
||
"
|
||
::= { pmops2dCfgLineStartupThreshEntry 4 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group other
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgOther OBJECT IDENTIFIER ::= { pmops2dConfig 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2300
|
||
--- *****************************************************
|
||
|
||
pmops2dtablemoduleOther OBJECT IDENTIFIER ::= { pmops2dCfgOther 1 }
|
||
|
||
|
||
|
||
pmops2dCfgoutOfService OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Setting on the OOS of
|
||
the OPS :This register configures
|
||
the default mode on the OOS of
|
||
the OPS
|
||
"
|
||
::= { pmops2dtablemoduleOther 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group labels
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgLabels OBJECT IDENTIFIER ::= { pmops2dConfig 4 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgLabelclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmops2dCfgLabels 1 }
|
||
|
||
|
||
pmops2dCfgLabelclientEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmops2dCfgLabelclientIndex }
|
||
::= { pmops2dCfgLabelclientTable 1 }
|
||
|
||
|
||
Pmops2dCfgLabelclientEntry ::=
|
||
SEQUENCE {
|
||
pmops2dCfgLabelclientIndex
|
||
INTEGER,
|
||
pmops2dCfgLabelclientPortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmops2dCfgLabelclientIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelclient
|
||
table
|
||
"
|
||
::= { pmops2dCfgLabelclientEntry 1 }
|
||
|
||
|
||
pmops2dCfgLabelclientPortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the clients :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the ports.
|
||
"
|
||
::= { pmops2dCfgLabelclientEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmops2dCfgLabellineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmops2dCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmops2dCfgLabels 2 }
|
||
|
||
|
||
pmops2dCfgLabellineEntry OBJECT-TYPE
|
||
SYNTAX Pmops2dCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmops2dCfgLabellineIndex }
|
||
::= { pmops2dCfgLabellineTable 1 }
|
||
|
||
|
||
Pmops2dCfgLabellineEntry ::=
|
||
SEQUENCE {
|
||
pmops2dCfgLabellineIndex
|
||
INTEGER,
|
||
pmops2dCfgLabellinePortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmops2dCfgLabellineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelline
|
||
table
|
||
"
|
||
::= { pmops2dCfgLabellineEntry 1 }
|
||
|
||
|
||
pmops2dCfgLabellinePortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the lines :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the lines.
|
||
"
|
||
::= { pmops2dCfgLabellineEntry 3 }
|
||
|
||
|
||
|
||
pmops2dCfgWriteConfiguration OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write configuration to module:This OID
|
||
writes the complete configuration to the module"
|
||
::= { pmops2dConfig 257 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- TRAP OBJECTS
|
||
--- *****************************************************
|
||
|
||
pmops2dtrapPortNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last port which generates a trap"
|
||
::= { pmops2dtraps 2 }
|
||
|
||
pmops2dtrapLineNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last Line which generates a trap"
|
||
::= { pmops2dtraps 3 }
|
||
|
||
pmops2dtrapBoardNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last module which generates a trap"
|
||
::= { pmops2dtraps 4 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LINE TRAPS
|
||
--- *****************************************************
|
||
|
||
pmops2dLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmLineMeasWngPortn, pmops2dtrapLineNumber, pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmops2dAlmLineMeasWngPortn "on", pmops2dtrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on OPS of PMOPS2D in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default is activated"
|
||
::= { pmops2dtraps 30 }
|
||
|
||
pmops2dLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmLineMeasWngPortn, pmops2dtrapLineNumber, pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PMOPS2D Not Urgent ON"}
|
||
--&MATCH { pmops2dAlmLineMeasWngPortn "on", pmops2dtrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on OPS of PMOPS2D in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default disappeared"
|
||
::= { pmops2dtraps 31 }
|
||
|
||
pmops2dLineTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmLineMeasAlmPortn, pmops2dtrapLineNumber, pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D B Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmops2d2dAlmLineMeasAlmPortn "on", pmops2d2dtrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarms appears on OPS of PMOPS2D in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default is activated"
|
||
::= { pmops2dtraps 32 }
|
||
|
||
pmops2dLineTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmLineMeasAlmPortn, pmops2dtrapLineNumber, pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PMOPS2D Urgent ON"}
|
||
--&MATCH { pmops2dAlmLineMeasAlmPortn "on", pmops2dtrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on OPS of PMOPS2D in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default disappeared"
|
||
::= { pmops2dtraps 33 }
|
||
|
||
pmops2dLineTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmLineFailAccPortn , pmops2dAlmLineHwFailAccPortn , pmops2dtrapLineNumber, pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmops2dAlmLineFailAccPortn "on", pmops2dAlmLineHwFailAccPortn "*", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Critical alarm appears on OPS of PMOPS2D in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOPS2D HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmops2dAlmLineFailAccPortn "*", pmops2dAlmLineHwFailAccPortn "on", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Critical alarm appears on OPS of PMOPS2D in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default is activated"
|
||
::= { pmops2dtraps 34 }
|
||
|
||
pmops2dLineTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmLineFailAccPortn , pmops2dAlmLineHwFailAccPortn , pmops2dtrapLineNumber, pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PMOPS2D Fail ON" }
|
||
--&MATCH { pmops2dAlmLineFailAccPortn "on", pmops2dAlmLineHwFailAccPortn "*", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Critical alarm disappears on OPS of PMOPS2D in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOPS2D HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmops2dAlmLineFailAccPortn "*", pmops2dAlmLineHwFailAccPortn "on", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Critical alarm disappears on OPS of PMOPS2D in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default disappeared"
|
||
::= { pmops2dtraps 35 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- CLIENT TRAPS
|
||
--- *****************************************************
|
||
|
||
pmops2dClientTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmClientFailAccPortn, pmops2dAlmClientHwFailAccPortn, pmops2dtrapPortNumber, pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmops2dAlmClientFailAccPortn "on", pmops2dAlmClientHwFailAccPortn "*", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Critical alarm appears on OPS of PMOPS2D in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOPS2D HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmops2dAlmClientFailAccPortn "*", pmops2dAlmClientHwFailAccPortn "on", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Critical alarm appears on OPS of PMOPS2D in Slot $3 ($A)"
|
||
DESCRIPTION "Critical client default is activated"
|
||
::= { pmops2dtraps 44 }
|
||
|
||
pmops2dClientTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmClientFailAccPortn, pmops2dAlmClientHwFailAccPortn, pmops2dtrapPortNumber, pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PMOPS2D Fail ON" }
|
||
--&MATCH { pmops2dAlmClientFailAccPortn "on", pmops2dAlmClientHwFailAccPortn "*", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Critical alarm disappears on OPS of PMOPS2D in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOPS2D HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmops2dAlmClientFailAccPortn "*", pmops2dAlmClientHwFailAccPortn "on", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Critical alarm disappears on OPS of PMOPS2D in Slot $3 ($A)"
|
||
DESCRIPTION "Critical client default disappeared"
|
||
::= { pmops2dtraps 45 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- HW TRAPS
|
||
--- *****************************************************
|
||
|
||
pmops2dPowerTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmDefFuseB, pmops2dAlmDefFuseA , pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Fuse A Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmops2dAlmDefFuseB "*", pmops2dAlmDefFuseA "on", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Power Input A Fail on PMOPS2D in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOPS2D Fuse B Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmops2dAlmDefFuseB "on", pmops2dAlmDefFuseA "*", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Power Input B Fail on PMOPS2D in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default is activated"
|
||
::= { pmops2dtraps 50 }
|
||
|
||
pmops2dPowerTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmops2dAlmDefFuseB, pmops2dAlmDefFuseA , pmops2dtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOPS2D Fuse A&B Fail OFF"
|
||
--&ACTIONS { log, normal}
|
||
--&CLEARS { "PMOPS2D Fuse A Fail ON", "PMOPS2D Fuse B Fail ON" }
|
||
--&MATCH { pmops2dAlmDefFuseB "on", pmops2dAlmDefFuseA "on", pmops2dtrapBoardNumber "$3"}
|
||
--&MESG "Power Inputs A and B Present on PMOPS2D in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default disappeared"
|
||
::= { pmops2dtraps 51 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
END
|