-- EKINOPS-pmoa.TXT: MIB
|
||
--
|
||
--MIB Part Number:3MI00200AJAD
|
||
--MIB Version:01
|
||
--
|
||
-- Copyright (c) 2016 by Ekinops
|
||
-- All rights reserved.
|
||
--
|
||
-- *****************************************************************
|
||
|
||
EKINOPS-PmOa-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
ekinops,
|
||
EkiState,
|
||
EkiOnOff,
|
||
EkiMode,
|
||
EkiProtocol,
|
||
EkiApiState,
|
||
EkiSynchroMode,
|
||
EkiMeasureType
|
||
FROM EKINOPS-MIB
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Unsigned32,
|
||
Integer32,
|
||
Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION,
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
modulepmoa MODULE-IDENTITY
|
||
LAST-UPDATED "201605230000Z"
|
||
ORGANIZATION "Ekinops"
|
||
CONTACT-INFO
|
||
"Ekinops
|
||
|
||
3, rue Blaise Pascal
|
||
F-22300 Lannion / FRANCE
|
||
|
||
Tel : +33 (0)2 96 05 00 30
|
||
Fax : +33 (0)2 96 48 62 39
|
||
|
||
E-mail: support@ekinops.net"
|
||
DESCRIPTION
|
||
"MIB for the Ekinops pmoa hardware."
|
||
REVISION "200601050000Z"
|
||
DESCRIPTION
|
||
"Initial Version."
|
||
REVISION "200711210000Z"
|
||
DESCRIPTION
|
||
"UPdate Ekinops address, Helps on objects, Ports labels"
|
||
REVISION "200902050000Z"
|
||
DESCRIPTION
|
||
"Add ext Pumps features"
|
||
REVISION "200904080000Z"
|
||
DESCRIPTION
|
||
"Cosmetic for mib compilers"
|
||
REVISION "200909140000Z"
|
||
DESCRIPTION
|
||
"CondType parameters insertion"
|
||
REVISION "200912140000Z"
|
||
DESCRIPTION
|
||
"Correction on traps"
|
||
REVISION "201002240000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS"
|
||
REVISION "201007150000Z"
|
||
DESCRIPTION
|
||
"Add inventory objet for the NMS"
|
||
REVISION "201010290000Z"
|
||
DESCRIPTION
|
||
"Formula in comments, Objects removal"
|
||
|
||
REVISION "201011030000Z"
|
||
DESCRIPTION
|
||
"Modify inventory objet for the NMS"
|
||
REVISION "201207040000Z"
|
||
DESCRIPTION
|
||
"Minor cosmetic updates"
|
||
REVISION "201210050000Z"
|
||
DESCRIPTION
|
||
"Minor labels changes"
|
||
REVISION "201403260000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS completion"
|
||
REVISION "201411240000Z"
|
||
DESCRIPTION
|
||
"Labels cosmetic updates"
|
||
REVISION "201605230000Z"
|
||
DESCRIPTION
|
||
"New AlarmType <20> synthesisAlarm (12)"
|
||
::= { ekinops 9 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF LEVEL 2
|
||
--- *****************************************************
|
||
|
||
|
||
pmoaalarms OBJECT IDENTIFIER ::= { modulepmoa 2 }
|
||
pmoaAlmOther OBJECT IDENTIFIER ::= { pmoaalarms 1 }
|
||
pmoaAlmOtherNurg OBJECT IDENTIFIER ::= { pmoaAlmOther 1 }
|
||
pmoaAlmOtherUrg OBJECT IDENTIFIER ::= { pmoaAlmOther 2 }
|
||
pmoaAlmOtherCrit OBJECT IDENTIFIER ::= { pmoaAlmOther 3 }
|
||
|
||
pmoaAlmClient OBJECT IDENTIFIER ::= { pmoaalarms 2 }
|
||
pmoaAlmClientNurg OBJECT IDENTIFIER ::= { pmoaAlmClient 1 }
|
||
pmoaAlmClientUrg OBJECT IDENTIFIER ::= { pmoaAlmClient 2 }
|
||
pmoaAlmClientCrit OBJECT IDENTIFIER ::= { pmoaAlmClient 3 }
|
||
|
||
pmoaAlmLine OBJECT IDENTIFIER ::= { pmoaalarms 3 }
|
||
pmoaAlmLineNurg OBJECT IDENTIFIER ::= { pmoaAlmLine 1 }
|
||
pmoaAlmLineUrg OBJECT IDENTIFIER ::= { pmoaAlmLine 2 }
|
||
pmoaAlmLineCrit OBJECT IDENTIFIER ::= { pmoaAlmLine 3 }
|
||
|
||
|
||
pmoameasures OBJECT IDENTIFIER ::= { modulepmoa 3 }
|
||
pmoaMesrOther OBJECT IDENTIFIER ::= { pmoameasures 1 }
|
||
pmoaMesrClient OBJECT IDENTIFIER ::= { pmoameasures 2 }
|
||
pmoaMesrLine OBJECT IDENTIFIER ::= { pmoameasures 3 }
|
||
|
||
|
||
pmoacontrolsWrite OBJECT IDENTIFIER ::= { modulepmoa 6 }
|
||
pmoaCtrlOther OBJECT IDENTIFIER ::= { pmoacontrolsWrite 1 }
|
||
pmoaCtrlClient OBJECT IDENTIFIER ::= { pmoacontrolsWrite 2 }
|
||
pmoaCtrlLine OBJECT IDENTIFIER ::= { pmoacontrolsWrite 3 }
|
||
|
||
pmoari OBJECT IDENTIFIER ::= { modulepmoa 7 }
|
||
|
||
|
||
pmoaConfig OBJECT IDENTIFIER ::= { modulepmoa 9 }
|
||
|
||
pmoatraps OBJECT IDENTIFIER ::= { modulepmoa 10 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- TEXTUAL-CONVENTION
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
PmoapreampMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on OA preamp"
|
||
SYNTAX INTEGER {
|
||
oapreampdefaultmode(0),
|
||
oapreampconstantcurrentmode(1),
|
||
oapreampconstantpowermode(2)
|
||
|
||
}
|
||
|
||
PmoaboosterMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on OA booster"
|
||
SYNTAX INTEGER {
|
||
oaboosterdefaultmode(0),
|
||
oaboosterconstantcurrentmode(1),
|
||
oaboosterconstantpowermode(2)
|
||
|
||
}
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- REMOTE INVENTORY
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
pmoaRinvReloadInventory OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reload the inventory: This OID triggers an
|
||
inventory reload."
|
||
::= { pmoari 2 }
|
||
|
||
pmoaRinvModulePlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Module platform description: This OID contains the
|
||
description of the Module."
|
||
::= { pmoari 3 }
|
||
|
||
pmoaRinvSwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SW platform description: This OID contains the
|
||
description of the Software platform."
|
||
::= { pmoari 4 }
|
||
|
||
pmoaRinvSwFoa OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Optical device driver description: This OID contains
|
||
the description of the driver of the optical devices
|
||
(Booster and Pre-Amp)"
|
||
::= { pmoari 5 }
|
||
|
||
|
||
pmoaRinvBoosterTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmoaRinvBoosterEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the Boosters on the selected module"
|
||
::= { pmoari 6 }
|
||
|
||
pmoaRinvBoosterEntry OBJECT-TYPE
|
||
SYNTAX PmoaRinvBoosterEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the Boosters table"
|
||
INDEX { pmoaRinvBoosterIndex }
|
||
::= { pmoaRinvBoosterTable 1 }
|
||
|
||
|
||
|
||
PmoaRinvBoosterEntry::=
|
||
SEQUENCE {
|
||
pmoaRinvBoosterIndex
|
||
Integer32,
|
||
pmoaRinvBooster
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmoaRinvBoosterIndex OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for Booster table"
|
||
::= { pmoaRinvBoosterEntry 1 }
|
||
|
||
|
||
pmoaRinvBooster OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the Booster: This OID contains the inventory for the Booster"
|
||
::= { pmoaRinvBoosterEntry 2 }
|
||
|
||
|
||
|
||
|
||
pmoaRinvPreAmpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmoaRinvPreAmpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the PreAmps on the selected module"
|
||
::= { pmoari 7 }
|
||
|
||
pmoaRinvPreAmpEntry OBJECT-TYPE
|
||
SYNTAX PmoaRinvPreAmpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the PreAmp table"
|
||
INDEX { pmoaRinvPreAmpIndex }
|
||
::= { pmoaRinvPreAmpTable 1 }
|
||
|
||
|
||
|
||
PmoaRinvPreAmpEntry::=
|
||
SEQUENCE {
|
||
pmoaRinvPreAmpIndex
|
||
Integer32,
|
||
pmoaRinvPreAmp
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmoaRinvPreAmpIndex OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for PreAmp table"
|
||
::= { pmoaRinvPreAmpEntry 1 }
|
||
|
||
|
||
pmoaRinvPreAmp OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the PreAmp: This OID contains the inventory for the PreAmp"
|
||
::= { pmoaRinvPreAmpEntry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- ALARMS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm0 article
|
||
--- *****************************************************
|
||
pmoaAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoaAlmOtherCrit 0 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmDefFuseB OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse B Fail :This OID indicates
|
||
that the fuse of the power input
|
||
B is in fail condition <Help>
|
||
Status of the Fuse B <Condtype>
|
||
DEF_FUSE_B <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm0 16 }
|
||
|
||
|
||
|
||
pmoaAlmDefFuseA OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse A Fail :This OID indicates
|
||
that the fuse of the power input
|
||
A is in fail condition <Help>
|
||
Status of the Fuse A <Condtype>
|
||
DEF_FUSE_A <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm0 15 }
|
||
|
||
|
||
|
||
pmoaAlmExtPumpNotLocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
External Pump1 Not Detected :This
|
||
OID indicates that the first external
|
||
pump is not detected by the amplifier
|
||
module <Help> This alarm indicates
|
||
if the first external pump is detected
|
||
by the amplifier module <Condtype>
|
||
EXT_PUMP_NOT_LOCKED <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm0 12 }
|
||
|
||
|
||
|
||
pmoaAlmDwEdfaInitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Not Initialized :This
|
||
OID indicates that the initialisation
|
||
of the Pre-Amp is not completed
|
||
<Help> This status indicates
|
||
if the Pre-Amp has been correctly
|
||
initialized <Condtype> DW_EDFA_INIT_NOT_COMPL
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm0 11 }
|
||
|
||
|
||
|
||
pmoaAlmUpEdfaInitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Not Initialized :This
|
||
OID indicates that the initialisation
|
||
of the Booster is not completed
|
||
<Help> This status indicates
|
||
if the Booster has been correctly
|
||
initialized <Condtype> UP_EDFA_INIT_NOT_COMPL
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm0 10 }
|
||
|
||
|
||
|
||
pmoaAlmModGlobFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Failure :This OID is set
|
||
on detection of a failure originating
|
||
from the PM <Condtype> MOD_GLOB_FAIL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm0 9 }
|
||
|
||
|
||
|
||
pmoaAlmMaintenanceMode OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Maintenance Mode :This OID indicates
|
||
that the PM is in maintenance mode
|
||
<Help> This status indiates if
|
||
the module is currently in maintenance
|
||
mode <Condtype> MAINTENANCE_MODE
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm2 article
|
||
--- *****************************************************
|
||
pmoaAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoaAlmOtherNurg 2 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmConfTableLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Load :This OID
|
||
is at 1 during the loading of
|
||
configuration tables in the modules
|
||
RAM. <Condtype> CONF_TABLE_LOAD
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm2 3 }
|
||
|
||
|
||
|
||
pmoaAlmInvUpload OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Inventory Upload :This OID is
|
||
at 1 during the uploading of PM
|
||
inventory information. <Condtype>
|
||
INV_UPLOAD <Probcause> other (1)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoaAlmsynthAlm2 2 }
|
||
|
||
|
||
|
||
pmoaAlmConfTableSave OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Save :This OID
|
||
is at 1 during the saving of a
|
||
new configuration table in the
|
||
module Flash memory. <Condtype>
|
||
CONF_TABLE_SAVE <Probcause> other
|
||
(1) <Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoaAlmsynthAlm2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm7 article
|
||
--- *****************************************************
|
||
pmoaAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoaAlmLineCrit 7 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmLineFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port Failure :This OID indicates
|
||
a failure on the line port <Condtype>
|
||
LINE_FAIL <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm7 12 }
|
||
|
||
|
||
|
||
pmoaAlmLineDdmAlm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Line Optical Module DDM
|
||
:This OID indicates an alarm is
|
||
present coming out of Line optical
|
||
interface DDM <Condtype> LINE_DDM_ALM
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm7 10 }
|
||
|
||
|
||
|
||
pmoaAlmLineDdmWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Line Optical Module
|
||
DDM :This OID indicates a warning
|
||
is present coming out of Line optical
|
||
interface DDM <Condtype> LINE_DDM_WARNING
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm7 9 }
|
||
|
||
|
||
|
||
pmoaAlmLineTxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Optical Output Shutdown
|
||
:This OID indicates the Booster
|
||
optical output power is on <Help>
|
||
This status indicates if the Booster
|
||
laser pump is ON or OFF <Condtype>
|
||
LINE_TX_OFF <Probcause> other (1)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm7 5 }
|
||
|
||
|
||
|
||
pmoaAlmLineHwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port HW Failure :This OID
|
||
indicates a failure on line port,
|
||
most probably caused by a HW issue
|
||
<Condtype> LINE_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoaAlmsynthAlm7 4 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm8 article
|
||
--- *****************************************************
|
||
pmoaAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoaAlmClientCrit 8 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmClientFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Client Port Failure :This OID
|
||
indicates a failure on the Client
|
||
port <Condtype> CLIENT_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoaAlmsynthAlm8 12 }
|
||
|
||
|
||
|
||
pmoaAlmClientDdmAlm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Client Optical Module
|
||
DDM :This OID indicates an alarm
|
||
is present coming out of Client
|
||
optical interface DDM <Condtype>
|
||
CLIENT_DDM_ALM <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm8 10 }
|
||
|
||
|
||
|
||
pmoaAlmClientDdmWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Client Optical Module
|
||
DDM :This OID indicates a warning
|
||
is present coming out of Client
|
||
optical interface DDM <Condtype>
|
||
CLIENT_DDM_WARNING <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoaAlmsynthAlm8 9 }
|
||
|
||
|
||
|
||
pmoaAlmClientTxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Optical Output Shutdown
|
||
:This OID indicates the Pre-Amp
|
||
optical output power is on <Help>
|
||
This status indicates if the Pre-Amp
|
||
laser pump transceiver laser is
|
||
ON or OFF <Condtype> CLIENT_TX_OFF
|
||
<Probcause> other (1) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmsynthAlm8 5 }
|
||
|
||
|
||
|
||
pmoaAlmClientHwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Client Port HW Failure :This OID
|
||
indicates a failure on Client port,
|
||
most probably caused by a HW issue
|
||
<Condtype> CLIENT_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoaAlmsynthAlm8 4 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaAlarms1 article
|
||
--- *****************************************************
|
||
pmoaAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoaAlmClientUrg 32 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmClientBiasHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Bias High Alarm :This
|
||
OID indicates that the Bias is
|
||
higher than the alarm theshold
|
||
of the Pre-Amp Optical Module
|
||
<Help> This alarm indicates
|
||
if the Pre-Amp bias is too high
|
||
<Condtype> CLIENT_BIAS_HIGH_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms1 8 }
|
||
|
||
|
||
|
||
pmoaAlmClientBiasLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Bias Low Alarm :This OID
|
||
indicates that the Bias is lower
|
||
than the alarm theshold of the
|
||
Pre-Amp Optical Module <Help>
|
||
This alarm indicates if the Pre-Amp
|
||
bias is too low <Condtype> CLIENT_BIAS_LOW_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms1 7 }
|
||
|
||
|
||
|
||
pmoaAlmClientOutputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Tx Pwr High Alarm :This
|
||
OID indicates that the Transmit
|
||
Power is higher than the alarm
|
||
theshold of the Pre-Amp Optical
|
||
Module <Help> This alarm indicates
|
||
if the Pre-Amp tx power is too
|
||
high <Condtype> CLIENT_OUTPUT_PWR_HIGH_ALARM
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms1 6 }
|
||
|
||
|
||
|
||
pmoaAlmClientOutputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Tx Pwr Low Alarm :This
|
||
OID indicates that the Transmit
|
||
Power is lower than the alarm theshold
|
||
of the Pre-Amp Optical Module
|
||
<Help> This alarm indicates if
|
||
the Pre-Amp tx power is too low
|
||
<Condtype> CLIENT_OUTPUT_PWR_LOW_ALARM
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms1 5 }
|
||
|
||
|
||
|
||
pmoaAlmClientInputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Rx Pwr High Alarm :This
|
||
OID indicates that the Receive
|
||
Power is higher than the alarm
|
||
theshold of the Booster Optical
|
||
Module <Help> This alarm indicates
|
||
if the Booster rx power is too
|
||
high <Condtype> CLIENT_INPUT_PWR_HIGH_ALARM
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms1 4 }
|
||
|
||
|
||
|
||
pmoaAlmClientInputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Rx Pwr Low Alarm :This
|
||
OID indicates that the Receive
|
||
Power is lower than the alarm
|
||
theshold of the Booster Optical
|
||
Module <Help> This alarm indicates
|
||
if the Booster rx power is too
|
||
low <Condtype> CLIENT_INPUT_PWR_LOW_ALARM
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms1 3 }
|
||
|
||
|
||
|
||
pmoaAlmClientGainHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Gain High Alarm :This
|
||
OID indicates that the Gain is
|
||
higher than the alarm threshold
|
||
of the Pre-Amp Module <Help>
|
||
This alarm indicates if the Pre-Amp
|
||
gain is too high <Condtype> CLIENT_GAIN_HIGH_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms1 2 }
|
||
|
||
|
||
|
||
pmoaAlmClientGainLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Gain Low Alarm :This OID
|
||
indicates that the Gain is lower
|
||
than the alarm theshold of the
|
||
Pre-Amp Module <Help> This alarm
|
||
indicates if the Pre-Amp gain is
|
||
too low <Condtype> CLIENT_GAIN_LOW_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaWarnings article
|
||
--- *****************************************************
|
||
pmoaAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoaAlmClientNurg 33 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmClientBiasHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Bias High Warning :This
|
||
OID indicates that the Bias is
|
||
higher than the Warning theshold
|
||
of the Pre-Amp Optical Module
|
||
<Help> This warning indicates
|
||
if the Pre-Amp bias is too high
|
||
<Condtype> CLIENT_BIAS_HIGH_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaWarnings 8 }
|
||
|
||
|
||
|
||
pmoaAlmClientBiasLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Bias Low Warning :This
|
||
OID indicates that the Bias is
|
||
lower than the Warning theshold
|
||
of the Pre-Amp Optical Module
|
||
<Help> This warning indicates
|
||
if the Pre-Amp bias is too low
|
||
<Condtype> CLIENT_BIAS_LOW_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaWarnings 7 }
|
||
|
||
|
||
|
||
pmoaAlmClientOutputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Tx Pwr High Warning :This
|
||
OID indicates that the Transmit
|
||
Power is higher than the Warning
|
||
theshold of the Pre-Amp Optical
|
||
Module <Help> This warning indicates
|
||
if the Pre-Amp tx power is too
|
||
high <Condtype> CLIENT_OUTPUT_PWR_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaWarnings 6 }
|
||
|
||
|
||
|
||
pmoaAlmClientOutputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Tx Pwr Low Warning :This
|
||
OID indicates that the Transmit
|
||
Power is lower than the Warning
|
||
theshold of the Pre-Amp Optical
|
||
Module <Help> This warning indicates
|
||
if the Pre-Amp tx power is too
|
||
low <Condtype> CLIENT_OUTPUT_PWR_LOW_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaWarnings 5 }
|
||
|
||
|
||
|
||
pmoaAlmClientInputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Rx Pwr High Warning :This
|
||
OID indicates that the Receive
|
||
Power is higher than the Warning
|
||
theshold of the Booster Optical
|
||
Module <Help> This warning indicates
|
||
if the Booster rx power is too
|
||
high <Condtype> CLIENT_INPUT_PWR_HIGH_WARNING
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaWarnings 4 }
|
||
|
||
|
||
|
||
pmoaAlmClientInputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Rx Pwr Low Warning :This
|
||
OID indicates that the Receive
|
||
Power is lower than the Warning
|
||
theshold of the Booster Optical
|
||
Module <Help> This warning indicates
|
||
if the Booster rx power is too
|
||
low <Condtype> CLIENT_INPUT_PWR_LOW_WARNING
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaWarnings 3 }
|
||
|
||
|
||
|
||
pmoaAlmClientGainHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Gain High Warning :This
|
||
OID indicates that the Gain is
|
||
higher than the Warning threshold
|
||
of the Pre-Amp Module <Help>
|
||
This alarm indicates if the Pre-Amp
|
||
gain is too high <Condtype> CLIENT_GAIN_HIGH_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaWarnings 2 }
|
||
|
||
|
||
|
||
pmoaAlmClientGainLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Gain Low Warning :This
|
||
OID indicates that the Gain is
|
||
lower than the Warning theshold
|
||
of the Pre-Amp Module <Help>
|
||
This alarm indicates if the Pre-Amp
|
||
gain is too low <Condtype> CLIENT_GAIN_LOW_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaWarnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaAlarms2 article
|
||
--- *****************************************************
|
||
pmoaAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoaAlmClientCrit 35 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmClientExtPumpEdfaLowCurrent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp External Pump1 Low Current
|
||
:This OID indicates that the EDFA
|
||
pump current of the first external
|
||
pump linked to the Pre-Amp is too
|
||
low <Help> This alarm indicates
|
||
that the EDFA pump current of the
|
||
first external pump linked to the
|
||
Pre-Amp is too low <Condtype> CLIENT_EXT_PUMP_EDFA_LOW_CURRENT
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms2 5 }
|
||
|
||
|
||
|
||
pmoaAlmClientEdfaLos OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Loss Of Signal :This OID
|
||
indicates a Loss of Signal on the
|
||
Booster Optical Module <Help>
|
||
This alarm indicates if an optical
|
||
signal is detected on the Booster
|
||
input <Condtype> CLIENT_EDFA_LOS
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> physicalViolation (9)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms2 4 }
|
||
|
||
|
||
|
||
pmoaAlmClientEdfaLaserFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Pump Laser Fail :This
|
||
OID indicates a Transmit Laser
|
||
Fail on the Pre-Amp Optical Module
|
||
<Help> This alarm indicates if
|
||
the laser of the Pre-Amp is in
|
||
fail condition <Condtype> CLIENT_EDFA_LASER_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms2 3 }
|
||
|
||
|
||
|
||
pmoaAlmClientEdfaTecFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp TEC Fail :This OID indicates
|
||
that the TEC is in fail condition
|
||
on the Pre-Amp Optical Module
|
||
<Help> This alarm indicates if
|
||
the TEC of the Pre-Amp is in fail
|
||
condition <Condtype> CLIENT_EDFA_TEC_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms2 2 }
|
||
|
||
|
||
|
||
pmoaAlmClientEdfaNr OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Optical Module Not Ready
|
||
:This OID indicates that the Pre-Amp
|
||
Optical Module is not ready <Help>
|
||
This status indicates if the Pre-Amp
|
||
has been correctly initialized
|
||
<Condtype> CLIENT_EDFA_NR <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmclientEdfaAlarms2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaAlarms1 article
|
||
--- *****************************************************
|
||
pmoaAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoaAlmLineUrg 40 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmLineBiasHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Bias High Alarm :This
|
||
OID indicates that the Bias is
|
||
higher than the alarm theshold
|
||
of the Booster Optical Module
|
||
<Help> This alarm indicates
|
||
if the Booster bias is too high
|
||
<Condtype> LINE_BIAS_HIGH_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms1 8 }
|
||
|
||
|
||
|
||
pmoaAlmLineBiasLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Bias Low Alarm :This OID
|
||
indicates that the Bias is lower
|
||
than the alarm theshold of the
|
||
Booster Optical Module <Help>
|
||
This alarm indicates if the Booster
|
||
bias is too low <Condtype> LINE_BIAS_LOW_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms1 7 }
|
||
|
||
|
||
|
||
pmoaAlmLineOutputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Tx Pwr High Alarm :This
|
||
OID indicates that the Transmit
|
||
Power is higher than the alarm
|
||
theshold of the Booster Optical
|
||
Module <Help> This alarm indicates
|
||
if the Booster tx power is too
|
||
high <Condtype> LINE_OUTPUT_PWR_HIGH_ALARM
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms1 6 }
|
||
|
||
|
||
|
||
pmoaAlmLineOutputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Tx Pwr Low Alarm :This
|
||
OID indicates that the Transmit
|
||
Power is lower than the alarm theshold
|
||
of the Booster Optical Module
|
||
<Help> This alarm indicates if
|
||
the Booster tx power is too low
|
||
<Condtype> LINE_OUTPUT_PWR_LOW_ALARM
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms1 5 }
|
||
|
||
|
||
|
||
pmoaAlmLineInputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Rx Pwr High Alarm :This
|
||
OID indicates that the Receive
|
||
Power is higher than the alarm
|
||
theshold of the Pre-Amp Optical
|
||
Module <Help> This alarm indicates
|
||
if the Pre-Amp rx power is too
|
||
high <Condtype> LINE_INPUT_PWR_HIGH_ALARM
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms1 4 }
|
||
|
||
|
||
|
||
pmoaAlmLineInputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Rx Pwr Low Alarm :This
|
||
OID indicates that the Receive
|
||
Power is lower than the alarm
|
||
theshold of the Pre-Amp Optical
|
||
Module <Help> This alarm indicates
|
||
if the Pre-Amp rx power is too
|
||
low <Condtype> LINE_INPUT_PWR_LOW_ALARM
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms1 3 }
|
||
|
||
|
||
|
||
pmoaAlmLineGainHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Gain High Alarm :This
|
||
OID indicates that the Gain is
|
||
higher than the alarm threshold
|
||
of the Booster Module <Help>
|
||
This alarm indicates if the Booster
|
||
gain is too high <Condtype> LINE_GAIN_HIGH_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms1 2 }
|
||
|
||
|
||
|
||
pmoaAlmLineGainLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Gain Low Alarm :This OID
|
||
indicates that the Gain is lower
|
||
than the alarm theshold of the
|
||
Booster Module <Help> This alarm
|
||
indicates if the Booster gain is
|
||
too low <Condtype> LINE_GAIN_LOW_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaWarnings article
|
||
--- *****************************************************
|
||
pmoaAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoaAlmLineNurg 41 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmLineBiasHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Bias High Warning :This
|
||
OID indicates that the Bias is
|
||
higher than the Warning theshold
|
||
of the Booster Optical Module
|
||
<Help> This warning indicates
|
||
if the Booster bias is too high
|
||
<Condtype> LINE_BIAS_HIGH_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaWarnings 8 }
|
||
|
||
|
||
|
||
pmoaAlmLineBiasLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Bias Low Warning :This
|
||
OID indicates that the Bias is
|
||
lower than the Warning theshold
|
||
of the Booster Optical Module
|
||
<Help> This warning indicates
|
||
if the Booster bias is too low
|
||
<Condtype> LINE_BIAS_LOW_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaWarnings 7 }
|
||
|
||
|
||
|
||
pmoaAlmLineOutputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Tx Pwr High Warning :This
|
||
OID indicates that the Transmit
|
||
Power is higher than the Warning
|
||
theshold of the Booster Optical
|
||
Module <Help> This warning indicates
|
||
if the Booster tx power is too
|
||
high <Condtype> LINE_OUTPUT_PWR_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaWarnings 6 }
|
||
|
||
|
||
|
||
pmoaAlmLineOutputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Tx Pwr Low Warning :This
|
||
OID indicates that the Transmit
|
||
Power is lower than the Warning
|
||
theshold of the Booster Optical
|
||
Module <Help> This warning indicates
|
||
if the Booster tx power is too
|
||
low <Condtype> LINE_OUTPUT_PWR_LOW_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaWarnings 5 }
|
||
|
||
|
||
|
||
pmoaAlmLineInputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Rx Pwr High Warning :This
|
||
OID indicates that the Receive
|
||
Power is higher than the Warning
|
||
theshold of the Pre-Amp Optical
|
||
Module <Help> This warning indicates
|
||
if the Pre-Amp rx power is too
|
||
high <Condtype> LINE_INPUT_PWR_HIGH_WARNING
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaWarnings 4 }
|
||
|
||
|
||
|
||
pmoaAlmLineInputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Rx Pwr Low Warning :This
|
||
OID indicates that the Receive
|
||
Power is lower than the Warning
|
||
theshold of the Pre-Amp Optical
|
||
Module <Help> This warning indicates
|
||
if the Pre-Amp rx power is too
|
||
low <Condtype> LINE_INPUT_PWR_LOW_WARNING
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaWarnings 3 }
|
||
|
||
|
||
|
||
pmoaAlmLineGainHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Gain High Warning :This
|
||
OID indicates that the Gain is
|
||
higher than the Warning threshold
|
||
of the Booster Module <Help>
|
||
This alarm indicates if the Booster
|
||
gain is too high <Condtype> LINE_GAIN_HIGH_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaWarnings 2 }
|
||
|
||
|
||
|
||
pmoaAlmLineGainLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Gain Low Warning :This
|
||
OID indicates that the Gain is
|
||
lower than the Warning theshold
|
||
of the Booster Module <Help>
|
||
This alarm indicates if the Booster
|
||
gain is too low <Condtype> LINE_GAIN_LOW_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaWarnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaAlarms2 article
|
||
--- *****************************************************
|
||
pmoaAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoaAlmLineCrit 43 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster External Pump1 Low Current
|
||
:This OID indicates that the EDFA
|
||
pump current of the first external
|
||
pump linked to the Booster is too
|
||
low <Help> This alarm indicates
|
||
that the EDFA pump current of the
|
||
first external pump linked to the
|
||
Booster is too low. <Condtype>
|
||
LINE_EXT_PUMP_EDFA_LOW_CURRENT
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms2 5 }
|
||
|
||
|
||
|
||
pmoaAlmLineEdfaLos OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Loss Of Signal :This OID
|
||
indicates a Loss of Signal on the
|
||
Pre-Amp Optical Module <Help>
|
||
This alarm indicates if an optical
|
||
signal is detected on the Pre-Amp
|
||
input <Condtype> LINE_EDFA_LOS
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> physicalViolation (9)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms2 4 }
|
||
|
||
|
||
|
||
pmoaAlmLineEdfaLaserFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Pump Laser Fail :This
|
||
OID indicates a Transmit Laser
|
||
Fail on the Booster Optical Module
|
||
<Help> This alarm indicates if
|
||
the laser of the Booster is in
|
||
fail condition <Condtype> LINE_EDFA_LASER_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms2 3 }
|
||
|
||
|
||
|
||
pmoaAlmLineEdfaTecFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster TEC Fail :This OID indicates
|
||
that the TEC is in fail condition
|
||
on the Booster Optical Module
|
||
<Help> This alarm indicates if
|
||
the TEC of the Booster is in fail
|
||
condition <Condtype> LINE_EDFA_TEC_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms2 2 }
|
||
|
||
|
||
|
||
pmoaAlmLineEdfaNr OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Optical Module Not Ready
|
||
:This OID indicates that the Booster
|
||
Optical Module is not ready <Help>
|
||
This status indicates if the Booster
|
||
has been correctly initialized
|
||
<Condtype> LINE_EDFA_NR <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmlineEdfaAlarms2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the foaAlarms article
|
||
--- *****************************************************
|
||
pmoaAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoaAlmOtherUrg 74 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmTempHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Temperature High Alarm :This OID
|
||
indicates that the PM temperature
|
||
is higher than the alarm threshold
|
||
<Condtype> TEMP_HIGH_ALARM <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmfoaAlarms 8 }
|
||
|
||
|
||
|
||
pmoaAlmTermpLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Temperature Low Alarm :This OID
|
||
indicates that the PM temperature
|
||
if lower than the alarm threshold
|
||
<Condtype> TERMP_LOW_ALARM <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmfoaAlarms 7 }
|
||
|
||
|
||
|
||
pmoaAlm3v3HighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
3V3 High Alarm :This OID indicates
|
||
that the PM 3V3 voltage is higher
|
||
than the alarm threshold <Condtype>
|
||
3V3_HIGH_ALARM <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmfoaAlarms 6 }
|
||
|
||
|
||
|
||
pmoaAlm3v3LowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
3V3 Low Alarm :This OID indicates
|
||
that the PM 3V3 voltage is lower
|
||
than the alarm threshold <Condtype>
|
||
3V3_LOW_ALARM <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmfoaAlarms 5 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the foaWarnings article
|
||
--- *****************************************************
|
||
pmoaAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoaAlmOtherNurg 75 }
|
||
|
||
|
||
|
||
|
||
pmoaAlmTempHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Temperature High Warning :This
|
||
OID indicates that the PM temperature
|
||
if higher than the Warning threshold
|
||
<Condtype> TEMP_HIGH_WARNING <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmfoaWarnings 8 }
|
||
|
||
|
||
|
||
pmoaAlmTermpLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Temperature Low Warning :This
|
||
OID indicates that the PM temperature
|
||
if lower than the Warning threshold
|
||
<Condtype> TERMP_LOW_WARNING <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmfoaWarnings 7 }
|
||
|
||
|
||
|
||
pmoaAlm3v3HighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
3V3 High Warning :This OID indicates
|
||
that the PM 3V3 voltage is higher
|
||
than the Warning threshold <Condtype>
|
||
3V3_HIGH_WARNING <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmfoaWarnings 6 }
|
||
|
||
|
||
|
||
pmoaAlm3v3LowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
3V3 Low Warning :This OID indicates
|
||
that the PM 3V3 voltage is lower
|
||
than the Warning threshold <Condtype>
|
||
3V3_LOW_WARNING <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoaAlmfoaWarnings 5 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONTROLS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth0 article
|
||
--- *****************************************************
|
||
pmoaCtrlsynth0 OBJECT IDENTIFIER ::= { pmoaCtrlOther 0 }
|
||
|
||
|
||
|
||
|
||
pmoaCtrlConfClear OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Clear Configuration Tables :This
|
||
bit clears the configuration tables
|
||
from configuration in the flash.
|
||
<Help> This control restores
|
||
the default configuration of the
|
||
module
|
||
"
|
||
::= { pmoaCtrlsynth0 13 }
|
||
|
||
|
||
|
||
pmoaCtrlConfFlash OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Write Configuration Tables :This
|
||
bit saves the current configuration
|
||
of the module as configuration
|
||
in the flash. <Help> This control
|
||
saves the customer configuration
|
||
on the module
|
||
"
|
||
::= { pmoaCtrlsynth0 9 }
|
||
|
||
|
||
|
||
pmoaCtrlConfLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables :When
|
||
set this enables loading from flash
|
||
configuration1 into the module.
|
||
"
|
||
::= { pmoaCtrlsynth0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swMgnt article
|
||
--- *****************************************************
|
||
pmoaCtrlswMgnt OBJECT IDENTIFIER ::= { pmoaCtrlOther 5 }
|
||
|
||
|
||
|
||
|
||
pmoaCtrlWarmReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Warm Reset :This OID, when
|
||
set, causes a warm reset of the
|
||
Software. This reset is not traffic
|
||
affecting, and the configuration
|
||
of the Sofwtare remains unchanged.
|
||
<Help> This control initiates
|
||
a warm reset of the module.
|
||
"
|
||
::= { pmoaCtrlswMgnt 3 }
|
||
|
||
|
||
|
||
pmoaCtrlColdReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Cold Reset :This OID, when
|
||
set, causes a cold reset of the
|
||
Software. This reset is traffic
|
||
affecting, and the configuration
|
||
of Software is reloaded on start-up.
|
||
<Help> This control initiates
|
||
a cold reset of the module.
|
||
"
|
||
::= { pmoaCtrlswMgnt 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaLaserOff article
|
||
--- *****************************************************
|
||
pmoaCtrlclientEdfaLaserOff OBJECT IDENTIFIER ::= { pmoaCtrlClient 32 }
|
||
|
||
|
||
|
||
|
||
pmoaCtrlClientEdfaLaserOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Pump Laser Shutdown :This
|
||
OID switches OFF the laser of the
|
||
Pre-Amp Optical Module <Help>
|
||
This control defines the laser
|
||
state of the Pre-Amp
|
||
"
|
||
::= { pmoaCtrlclientEdfaLaserOff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaMode article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrlclientEdfaMode OBJECT-TYPE
|
||
SYNTAX PmoapreampMode
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Module Mode :This OID
|
||
selects the mode of the Pre-Amp
|
||
Module <Help> This control defines
|
||
the Pre-Amp Mode (0: Default mode,
|
||
2:Constant output power)
|
||
"
|
||
::= { pmoaCtrlClient 33 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientIlasSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrlclientIlasSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Laser Current Value :This
|
||
OID sets the value of the laser
|
||
current of the Pre-Amp Module (active
|
||
only in constant current mode)
|
||
(AV = Current *100) (Unit = mA)
|
||
<Help> This control defines the
|
||
Pre-Amp Laser current in mA (valid
|
||
only in constant current mode)
|
||
"
|
||
::= { pmoaCtrlClient 34 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientPlasSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrlclientPlasSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Pump Power Value :This
|
||
OID sets the value of the laser
|
||
power of the Pre-Amp Optical Module
|
||
(active only in constant power
|
||
mode) (AV=(Power/0,005) + 32768)
|
||
(Unit = dBm) <Help> This control
|
||
defines the Pre-Amp laser power
|
||
in dBm (valid only in constant
|
||
output power mode)
|
||
"
|
||
::= { pmoaCtrlClient 35 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientGainSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrlclientGainSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Gain Value :This OID sets
|
||
the value of the gain of the Pre-Amp
|
||
Module (active only in constant
|
||
gain mode) (AV=(Gain/0,005) + 32768)
|
||
(Unit = dB)
|
||
"
|
||
::= { pmoaCtrlClient 36 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEffPwrOutSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrlclientEffPwrOutSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Effective Output Power
|
||
:This OID sets the value of the
|
||
effective output power (without
|
||
noise power) of the Pre-Amp Module
|
||
(active only in input power function
|
||
mode) (AV=(Power/0,005) + 32768)
|
||
(Unit = dBm) <Help> This control
|
||
defines the Pre-Amp effective output
|
||
power in dBm (valid only in Effective
|
||
Ouput power mode).
|
||
"
|
||
::= { pmoaCtrlClient 37 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaLaserOff article
|
||
--- *****************************************************
|
||
pmoaCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoaCtrlLine 40 }
|
||
|
||
|
||
|
||
|
||
pmoaCtrlLineEdfaLaserOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Pump Laser Shutdown :This
|
||
OID switches OFF the laser of the
|
||
Booster Optical Module <Help>
|
||
This control defines the laser
|
||
state of the Booster
|
||
"
|
||
::= { pmoaCtrllineEdfaLaserOff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaMode article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrllineEdfaMode OBJECT-TYPE
|
||
SYNTAX PmoaboosterMode
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Module Mode :This OID
|
||
selects the mode of the Booster
|
||
Module <Help> This control defines
|
||
the Booster Mode (0: Default mode,
|
||
2:Constant output power)
|
||
"
|
||
::= { pmoaCtrlLine 41 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineIlasSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrllineIlasSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Laser Current Value :This
|
||
OID sets the value of the laser
|
||
current of the Booster Module (active
|
||
only in constant current mode)
|
||
(AV = Current *100) (Unit = mA)
|
||
<Help> This control defines the
|
||
Booster Laser current in mA (valid
|
||
only in constant current mode)
|
||
"
|
||
::= { pmoaCtrlLine 42 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the linePlasSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrllinePlasSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Pump Power Value :This
|
||
OID sets the value of the laser
|
||
power of the Booster Optical Module
|
||
(active only in constant power
|
||
mode) (AV=(Power/0,005) + 32768)
|
||
(Unit = dBm) <Help> This control
|
||
defines the Booster laser power
|
||
in dBm (valid only in constant
|
||
output power mode)
|
||
"
|
||
::= { pmoaCtrlLine 43 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineGainSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrllineGainSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Gain Value :This OID sets
|
||
the value of the gain of the Booster
|
||
Module (active only in constant
|
||
gain mode) (AV=(Gain/0,005) + 32768)
|
||
(Unit = dB)
|
||
"
|
||
::= { pmoaCtrlLine 44 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEffPwrOutSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoaCtrllineEffPwrOutSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Effective Output Power
|
||
:This OID sets the value of the
|
||
effective output power (without
|
||
noise power) of the Booster Module
|
||
(active only in input power function
|
||
mode) (AV=(Power/0,005) + 32768)
|
||
(Unit = dBm)
|
||
"
|
||
::= { pmoaCtrlLine 45 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the powerDown article
|
||
--- *****************************************************
|
||
pmoaCtrlpowerDown OBJECT IDENTIFIER ::= { pmoaCtrlOther 72 }
|
||
|
||
|
||
|
||
|
||
pmoaCtrlSoftPowerDown OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Software Shutdown :This
|
||
OID shuts down the PM Software
|
||
<Help> This control initiates
|
||
a shut down of software.
|
||
"
|
||
::= { pmoaCtrlpowerDown 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the ledTest article
|
||
--- *****************************************************
|
||
pmoaCtrlledTest OBJECT IDENTIFIER ::= { pmoaCtrlOther 73 }
|
||
|
||
|
||
|
||
|
||
pmoaCtrlLedOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Leds Off :This OID switches off
|
||
all the Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to OFF
|
||
"
|
||
::= { pmoaCtrlledTest 3 }
|
||
|
||
|
||
|
||
pmoaCtrlRedLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Red Leds Test :This OID switches
|
||
on all the red Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to red
|
||
"
|
||
::= { pmoaCtrlledTest 2 }
|
||
|
||
|
||
|
||
pmoaCtrlGreenLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Green Leds Test :This OID switches
|
||
on all the green Leds as a test
|
||
feature. <Help> This control
|
||
initiates a test leds turning
|
||
all the LEDs to green
|
||
"
|
||
::= { pmoaCtrlledTest 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the maintMode article
|
||
--- *****************************************************
|
||
pmoaCtrlmaintMode OBJECT IDENTIFIER ::= { pmoaCtrlOther 75 }
|
||
|
||
|
||
|
||
|
||
pmoaCtrlMaintenance OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Maintenance Mode :This
|
||
OID sets the PM in maintenance
|
||
mode <Help> This control enables
|
||
the maintenance mode of the module
|
||
"
|
||
::= { pmoaCtrlmaintMode 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- MEASURES
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaBiasMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrclientEdfaBiasMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Pump Laser Current :This
|
||
OID gives the pump laser current
|
||
of the Pre-Amp Optical Module (Current
|
||
=AV/100) (Unit = mA) <Help> This
|
||
measure gives the bias of the Pre-Amp
|
||
pump laser
|
||
"
|
||
::= { pmoaMesrClient 32 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaTxpwrMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrclientEdfaTxpwrMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Tx Power :This OID gives
|
||
the transmit power value of the
|
||
Pre-Amp Optical Module (Power =(AV-32768)*0,005)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Tx optical power of the
|
||
Pre-Amp
|
||
"
|
||
::= { pmoaMesrClient 33 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaRxpwrMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrclientEdfaRxpwrMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Rx Power :This OID gives
|
||
the receive power value of the
|
||
Booster Optical Module (Power
|
||
=(AV-32768)*0,005) (Unit = dBm)
|
||
<Help> This measure gives the
|
||
Rx optical power of the Booster
|
||
"
|
||
::= { pmoaMesrClient 34 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaGainMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrclientEdfaGainMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Gain :This OID gives the
|
||
gain value of the Pre-Amp Module
|
||
(Gain =(AV-32768)*0,005) (Unit
|
||
= dB) <Help> This measure gives
|
||
the optical gain of the Pre-Amp
|
||
"
|
||
::= { pmoaMesrClient 35 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaBiasMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrlineEdfaBiasMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Pump Laser Current :This
|
||
OID gives the pump laser current
|
||
of the Booster Optical Module
|
||
(Current =AV/100) (Unit = mA)
|
||
<Help> This measure gives the
|
||
bias of the Booster pump laser
|
||
"
|
||
::= { pmoaMesrLine 40 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaTxpwrMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrlineEdfaTxpwrMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Tx Power :This OID gives
|
||
the transmit power value of the
|
||
Booster Optical Module (Power =(AV-32768)*0,005)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Tx optical power of the
|
||
Booster
|
||
"
|
||
::= { pmoaMesrLine 41 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaRxpwrMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrlineEdfaRxpwrMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp Rx Power :This OID gives
|
||
the receive power value of the
|
||
Pre-Amp Optical Module (Power
|
||
=(AV-32768)*0,005) (Unit = dBm)
|
||
<Help> This measure gives the
|
||
Rx optical power of the Pre-Amp
|
||
"
|
||
::= { pmoaMesrLine 42 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaGainMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrlineEdfaGainMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster Gain :This OID gives the
|
||
gain value of the Booster Module
|
||
(Gain =(AV-32768)*0,005) (Unit
|
||
= dB) <Help> This measure gives
|
||
the optical gain of the Booster
|
||
"
|
||
::= { pmoaMesrLine 43 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the tempMeas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesrtempMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature :This OID gives
|
||
the temperature of the PM (Temperature
|
||
=AV/256) (Unit = C) <Help> This
|
||
measure gives the temperature of
|
||
the module
|
||
"
|
||
::= { pmoaMesrOther 72 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the 3v3Meas article
|
||
--- *****************************************************
|
||
|
||
pmoaMesr3v3Meas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module 3.3 Voltage :This OID gives
|
||
the 3V3 voltage of the PM (Voltage
|
||
=AV/10000) (Unit = V) <Help>
|
||
This measure gives the 3V3 voltage
|
||
of the module
|
||
"
|
||
::= { pmoaMesrOther 73 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONFIG
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group noValue
|
||
--- *****************************************************
|
||
|
||
pmoaCfgNoValue OBJECT IDENTIFIER ::= { pmoaConfig 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2111
|
||
--- *****************************************************
|
||
|
||
pmoatableclientStartup OBJECT IDENTIFIER ::= { pmoaCfgNoValue 1 }
|
||
|
||
|
||
|
||
pmoaCfgclientEdfaLaserCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client Laser
|
||
:This OID configures the default
|
||
initialisation settings on the
|
||
client laser.
|
||
"
|
||
::= { pmoatableclientStartup 2 }
|
||
|
||
|
||
|
||
pmoaCfgclientEdfaLaserMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client mode
|
||
:This OID configures the default
|
||
mode on the client amplifier.
|
||
"
|
||
::= { pmoatableclientStartup 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group lineStartUp
|
||
--- *****************************************************
|
||
|
||
pmoaCfgLineStartUp OBJECT IDENTIFIER ::= { pmoaConfig 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2191
|
||
--- *****************************************************
|
||
|
||
pmoatablelineStartup OBJECT IDENTIFIER ::= { pmoaCfgLineStartUp 1 }
|
||
|
||
|
||
|
||
pmoaCfglineEdfaLaserCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line Laser
|
||
:This OID configures the default
|
||
initialisation settings on the
|
||
line laser.
|
||
"
|
||
::= { pmoatablelineStartup 2 }
|
||
|
||
|
||
|
||
pmoaCfglineEdfaLaserMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line mode
|
||
:This OID configures the default
|
||
mode on the line amplifier.
|
||
"
|
||
::= { pmoatablelineStartup 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group labels
|
||
--- *****************************************************
|
||
|
||
pmoaCfgLabels OBJECT IDENTIFIER ::= { pmoaConfig 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmoaCfgLabelclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmoaCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmoaCfgLabels 1 }
|
||
|
||
|
||
pmoaCfgLabelclientEntry OBJECT-TYPE
|
||
SYNTAX PmoaCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmoaCfgLabelclientIndex }
|
||
::= { pmoaCfgLabelclientTable 1 }
|
||
|
||
|
||
PmoaCfgLabelclientEntry ::=
|
||
SEQUENCE {
|
||
pmoaCfgLabelclientIndex
|
||
INTEGER,
|
||
pmoaCfgLabelclientPortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmoaCfgLabelclientIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelclient
|
||
table
|
||
"
|
||
::= { pmoaCfgLabelclientEntry 1 }
|
||
|
||
|
||
pmoaCfgLabelclientPortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the Ports :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the ports.
|
||
"
|
||
::= { pmoaCfgLabelclientEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmoaCfgLabellineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmoaCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmoaCfgLabels 2 }
|
||
|
||
|
||
pmoaCfgLabellineEntry OBJECT-TYPE
|
||
SYNTAX PmoaCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmoaCfgLabellineIndex }
|
||
::= { pmoaCfgLabellineTable 1 }
|
||
|
||
|
||
PmoaCfgLabellineEntry ::=
|
||
SEQUENCE {
|
||
pmoaCfgLabellineIndex
|
||
INTEGER,
|
||
pmoaCfgLabellinePortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmoaCfgLabellineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelline
|
||
table
|
||
"
|
||
::= { pmoaCfgLabellineEntry 1 }
|
||
|
||
|
||
pmoaCfgLabellinePortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the lines :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the lines.
|
||
"
|
||
::= { pmoaCfgLabellineEntry 3 }
|
||
|
||
|
||
|
||
pmoaCfgWriteConfiguration OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write configuration to module:This OID
|
||
writes the complete configuration to the module"
|
||
::= { pmoaConfig 257 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- TRAP OBJECTS
|
||
--- *****************************************************
|
||
|
||
pmoatrapBoardNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last module which generates a trap"
|
||
::= { pmoatraps 4 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- GLOBAL TRAPS
|
||
--- *****************************************************
|
||
|
||
pmoaLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmLineDdmWarning, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Line Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmoaAlmLineDdmWarning "on", pmoatrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default is activated"
|
||
::= { pmoatraps 30 }
|
||
|
||
pmoaLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmLineDdmWarning, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Line Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOA Line Not Urgent ON"}
|
||
--&MATCH { pmoaAlmLineDdmWarning "on", pmoatrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default disappeared"
|
||
::= { pmoatraps 31 }
|
||
|
||
pmoaLineTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmLineDdmAlm, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Line Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmoaAlmLineDdmAlm "on", pmoatrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default is activated"
|
||
::= { pmoatraps 32 }
|
||
|
||
pmoaLineTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmLineDdmAlm, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Line Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOA Line Urgent ON"}
|
||
--&MATCH { pmoaAlmLineDdmAlm "on", pmoatrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default disappeared"
|
||
::= { pmoatraps 33 }
|
||
|
||
pmoaLineTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmLineFail, pmoaAlmLineHwFail, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Line Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmoaAlmLineFail "on", pmoaAlmLineHwFail "*", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOA Line HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmoaAlmLineFail "*", pmoaAlmLineHwFail "on", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default is activated"
|
||
::= { pmoatraps 34 }
|
||
|
||
pmoaLineTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmLineFail, pmoaAlmLineHwFail, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Line Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOA Line Fail ON"}
|
||
--&MATCH { pmoaAlmLineFail "on", pmoaAlmLineHwFail "*", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOA Line HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmoaAlmLineFail "*", pmoaAlmLineHwFail "on", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOA-BP in slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default disappeared"
|
||
::= { pmoatraps 35 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- PORTS TRAPS
|
||
--- *****************************************************
|
||
|
||
pmoaClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmClientDdmWarning, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Client Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmoaAlmClientDdmWarning "on", pmoatrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent client default is activated"
|
||
::= { pmoatraps 40 }
|
||
|
||
pmoaClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmClientDdmWarning, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Client Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOA Client Not Urgent ON"}
|
||
--&MATCH { pmoaAlmClientDdmWarning "on", pmoatrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent client default disappeared"
|
||
::= { pmoatraps 41 }
|
||
|
||
pmoaClientTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmClientDdmAlm, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Client Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmoaAlmClientDdmAlm "on", pmoatrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
|
||
DESCRIPTION "Urgent client default is activated"
|
||
::= { pmoatraps 42 }
|
||
|
||
pmoaClientTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmClientDdmAlm, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Client Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOA Client Urgent ON"}
|
||
--&MATCH { pmoaAlmClientDdmAlm "on", pmoatrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $2 ($A)"
|
||
DESCRIPTION "Urgent client default disappeared"
|
||
::= { pmoatraps 43 }
|
||
|
||
pmoaClientTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmClientFail, pmoaAlmClientHwFail, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Client Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmoaAlmClientFail "on", pmoaAlmClientHwFail "*", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOA Client HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmoaAlmClientFail "*", pmoaAlmClientHwFail "on", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
|
||
DESCRIPTION "Critical client default is activated"
|
||
::= { pmoatraps 44 }
|
||
|
||
pmoaClientTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmClientFail, pmoaAlmClientHwFail, pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Client Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOA Client Fail ON"}
|
||
--&MATCH { pmoaAlmClientFail "on", pmoaAlmClientHwFail "*", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOA Client HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmoaAlmClientFail "*", pmoaAlmClientHwFail "on", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOA-BP in slot $3 ($A)"
|
||
DESCRIPTION "Critical client default disappeared"
|
||
::= { pmoatraps 45 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- HW TRAPS
|
||
--- *****************************************************
|
||
|
||
pmoaPowerTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmDefFuseB, pmoaAlmDefFuseA , pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Fuse A Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmoaAlmDefFuseB "*", pmoaAlmDefFuseA "on", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Power Input A Fail on PMOA-BP in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOA Fuse B Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmoaAlmDefFuseB "on", pmoaAlmDefFuseA "*", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Power Input B Fail on PMOA-BP in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default is activated"
|
||
::= { pmoatraps 50 }
|
||
pmoaPowerTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoaAlmDefFuseB, pmoaAlmDefFuseA , pmoatrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOA Fuse A&B Fail OFF"
|
||
--&ACTIONS { log, normal}
|
||
--&CLEARS { "PMOA Fuse A Fail ON", "PMOA Fuse B Fail ON" }
|
||
--&MATCH { pmoaAlmDefFuseB "on", pmoaAlmDefFuseA "on", pmoatrapBoardNumber "$3"}
|
||
--&MESG "Power Inputs A and B Present on PMOA-BP in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default disappeared"
|
||
::= { pmoatraps 51 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
END
|