-- EKINOPS-PmDGE.TXT: MIB
--
--MIB Part Number:3MI00210AAAE
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-PmDGE-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulepmdge MODULE-IDENTITY
LAST-UPDATED "201605230000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.net"
DESCRIPTION
"MIB for the Ekinops Pmdge hardware."
REVISION "201210160000Z"
DESCRIPTION
"Initial Version."
REVISION "201303280000Z"
DESCRIPTION
"Express Input Att in Config"
REVISION "201403260000Z"
DESCRIPTION
"Probcause,AlarmType - NMS completion"
REVISION "201411250000Z"
DESCRIPTION
"Labels cosmetic updates"
REVISION "201605230000Z"
DESCRIPTION
"New AlarmType synthesisAlarm (12)"
::= { ekinops 56 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pmdgealarms OBJECT IDENTIFIER ::= { modulepmdge 2 }
pmdgeAlmOther OBJECT IDENTIFIER ::= { pmdgealarms 1 }
pmdgeAlmOtherNurg OBJECT IDENTIFIER ::= { pmdgeAlmOther 1 }
pmdgeAlmOtherUrg OBJECT IDENTIFIER ::= { pmdgeAlmOther 2 }
pmdgeAlmOtherCrit OBJECT IDENTIFIER ::= { pmdgeAlmOther 3 }
pmdgemeasures OBJECT IDENTIFIER ::= { modulepmdge 3 }
pmdgeMesrOther OBJECT IDENTIFIER ::= { pmdgemeasures 1 }
pmdgecontrolsWrite OBJECT IDENTIFIER ::= { modulepmdge 6 }
pmdgeCtrlOther OBJECT IDENTIFIER ::= { pmdgecontrolsWrite 1 }
pmdgeCtrlEqualizer OBJECT IDENTIFIER ::= { pmdgecontrolsWrite 2 }
pmdgeCtrlLine OBJECT IDENTIFIER ::= { pmdgecontrolsWrite 3 }
pmdgeri OBJECT IDENTIFIER ::= { modulepmdge 7 }
pmdgeriTable OBJECT IDENTIFIER ::= { pmdgeri 1 }
pmdgeConfig OBJECT IDENTIFIER ::= { modulepmdge 9 }
pmdgetraps OBJECT IDENTIFIER ::= { modulepmdge 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
PmdgeGrid ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different grids on line ports"
SYNTAX INTEGER {
dgegrid200(200),
dgegrid100(100),
dgegrid50(50)
}
PmdgePlanNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different values for plans"
SYNTAX INTEGER {
workingPlan(0),
savedPlan1(1),
savedPlan2(2),
usedPlan(7)
}
PmdgeChannel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Channel selection on line ports"
SYNTAX INTEGER {
}
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmdgeRinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pmdgeri 2 }
pmdgeRinvHwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pmdgeri 4 }
pmdgeRinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pmdgeri 5 }
pmdgeRinvPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmdgeRinvPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the Ports on the selected module"
::= { pmdgeriTable 1 }
pmdgeRinvPortEntry OBJECT-TYPE
SYNTAX PmdgeRinvPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the Port table"
INDEX { pmdgeRinvPortIndex }
::= { pmdgeRinvPortTable 1 }
PmdgeRinvPortEntry::=
SEQUENCE {
pmdgeRinvPortIndex
Integer32,
pmdgeRinvPort
DisplayString
}
pmdgeRinvPortIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for Port table"
::= { pmdgeRinvPortEntry 1 }
pmdgeRinvPort OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the Port: This OID contains the inventory for the Port"
::= { pmdgeRinvPortEntry 2 }
pmdgeRinvLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmdgeRinvLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the Lines on the selected module"
::= { pmdgeriTable 2 }
pmdgeRinvLineEntry OBJECT-TYPE
SYNTAX PmdgeRinvLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the Line table"
INDEX { pmdgeRinvLineIndex }
::= { pmdgeRinvLineTable 1 }
PmdgeRinvLineEntry::=
SEQUENCE {
pmdgeRinvLineIndex
Integer32,
pmdgeRinvxfpLine
DisplayString
}
pmdgeRinvLineIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for Line table"
::= { pmdgeRinvLineEntry 1 }
pmdgeRinvxfpLine OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the Line: This OID contains the inventory for the Line"
::= { pmdgeRinvLineEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pmdgeAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmdgeAlmOtherCrit 0 }
pmdgeAlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help>
Status of the Fuse B <Condtype>
DEF_FUSE_B <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmdgeAlmsynthAlm0 16 }
pmdgeAlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help>
Status of the Fuse A <Condtype>
DEF_FUSE_A <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmdgeAlmsynthAlm0 15 }
pmdgeAlmModuleGlobFailure OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the PM <Condtype> MODULE_GLOB_FAILURE
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmdgeAlmsynthAlm0 9 }
pmdgeAlmInServiceNotReady OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Building Waveplan :This OID is
a status indicating that the switch
is currently setting a new waveplan
(used plan) <Help> This status
indicates that the module is building
a new waveplan (used plan) <Condtype>
IN_SERVICE_NOT_READY <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmdgeAlmsynthAlm0 1 }
--- *****************************************************
--- LEAF for the synthAlm7 article
--- *****************************************************
pmdgeAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmdgeAlmOtherCrit 7 }
pmdgeAlmSwitchAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Equalizer :This OID indicates
an alarm is present coming out
of the switch <Help> This alarm
indicates if an Alarm has been
detected on the switch <Condtype>
SWITCH_ALM <Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmdgeAlmsynthAlm7 10 }
pmdgeAlmSwitchDegrade OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Equalizer :This OID
indicates a warning is present
coming out of the switch <Help>
This alarm indicates if a warning
has been detected on the switch
<Condtype> SWITCH_DEGRADE <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmdgeAlmsynthAlm7 9 }
pmdgeAlmInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Equalizer Not Ready :This OID
indicates the switch is not operational.
<Help> This status indicates
if the switch has been correctly
initialized <Condtype> INIT_NOT_COMPL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmdgeAlmsynthAlm7 2 }
--- *****************************************************
--- LEAF for the switchAlarms article
--- *****************************************************
pmdgeAlmswitchAlarms OBJECT IDENTIFIER ::= { pmdgeAlmOtherUrg 16 }
pmdgeAlmSwitchTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Equalizer Temperature High Alarm
:Alarm indicating that the temperature
of the Switch in the module is
higher than the alarm threshold
value <Help> This Alarm indicates
if the temperature of the Switch
in the module is higher than the
alarm threshold value. <Condtype>
SWITCH_TEMP_HIGH_ALA <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmdgeAlmswitchAlarms 2 }
--- *****************************************************
--- LEAF for the switchDegrade article
--- *****************************************************
pmdgeAlmswitchDegrade OBJECT IDENTIFIER ::= { pmdgeAlmOtherNurg 17 }
pmdgeAlmSwitchTempHighDeg OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Equalizer Temperature High Warning
:Warning indicating that the temperature
of the Switch in the module is
higher than the warning threshold
value. <Help> This Warning indicates
if the temperature of the Switch
in the module is higher than the
warning threshold value. <Condtype>
SWITCH_TEMP_HIGH_DEG <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmdgeAlmswitchDegrade 2 }
--- *****************************************************
--- LEAF for the moduleStatus article
--- *****************************************************
pmdgeAlmmoduleStatus OBJECT IDENTIFIER ::= { pmdgeAlmOtherUrg 66 }
pmdgeAlmSwitchNotReady OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Equalizer Not Ready :This OID
indicates the switch is not operational.
<Help> This status indicates
if the Switch of the module has
been correctly initialized <Condtype>
SWITCH_NOT_READY <Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmdgeAlmmoduleStatus 5 }
pmdgeAlmHotReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous Hot Reset : <Help>
This status indicates that the
previous reset was a Hot Reset.
<Condtype> HOT_RESET <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pmdgeAlmmoduleStatus 3 }
pmdgeAlmWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous Warm Reset : <Help>
This status indicates that the
previous reset was a Warm Reset.
<Condtype> WARM_RESET <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pmdgeAlmmoduleStatus 2 }
pmdgeAlmColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous Cold Reset : <Help>
This status indicates that the
previous reset was a Cold Reset.
<Condtype> COLD_RESET <Probcause>
other (1) <Alarmtype> other (1)
<Polarity> (2)
"
::= { pmdgeAlmmoduleStatus 1 }
--- *****************************************************
--- LEAF for the moduleAlarms article
--- *****************************************************
pmdgeAlmmoduleAlarms OBJECT IDENTIFIER ::= { pmdgeAlmOtherUrg 67 }
pmdgeAlmCaseTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Case Temperature High Alarm :Alarm
indicating that the temperature
of the case is higher than the
alarm threshold value <Help>
This Alarm indicates if the temperature
of the case is higher than the
alarm threshold value. <Condtype>
CASE_TEMP_HIGH_ALA <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmdgeAlmmoduleAlarms 4 }
pmdgeAlmModuleTempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature High Alarm
:Alarm indicating that the temperature
of the module is higher than the
alarm threshold value <Help>
This Alarm indicates if the temperature
of the module is higher than the
alarm threshold value. <Condtype>
MODULE_TEMP_HIGH_ALA <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmdgeAlmmoduleAlarms 2 }
--- *****************************************************
--- LEAF for the moduleDegrad article
--- *****************************************************
pmdgeAlmmoduleDegrad OBJECT IDENTIFIER ::= { pmdgeAlmOtherUrg 68 }
pmdgeAlmCaseTempHighDeg OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Case Temperature High Warning
:Alarm indicating that the temperature
of the case is higher than the
warning threshold value <Help>
This Warning indicates if the
temperature of the case is higher
than the warning threshold value.
<Condtype> CASE_TEMP_HIGH_DEG <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmdgeAlmmoduleDegrad 4 }
pmdgeAlmModuleTempHighDeg OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature High Warning
:Alarm indicating that the temperature
of the module is higher than the
warning threshold value <Help>
This Warning indicates if the
temperature of the module is higher
than the warning threshold value.
<Condtype> MODULE_TEMP_HIGH_DEG
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmdgeAlmmoduleDegrad 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synth0 article
--- *****************************************************
pmdgeCtrlsynth0 OBJECT IDENTIFIER ::= { pmdgeCtrlOther 0 }
pmdgeCtrlConfClear OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
bit clears the configuration tables
from configuration in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pmdgeCtrlsynth0 13 }
pmdgeCtrlConfFlash OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
bit saves the current configuration
of the module as configuration
in the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pmdgeCtrlsynth0 9 }
pmdgeCtrlConfLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables :When
set this enables loading from flash
configuration1 into the module.
"
::= { pmdgeCtrlsynth0 1 }
--- *****************************************************
--- LEAF for the synth4 article
--- *****************************************************
pmdgeCtrlsynth4 OBJECT IDENTIFIER ::= { pmdgeCtrlOther 4 }
pmdgeCtrlCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Disable Alarm Correlation :This
OID disables the alarm correlation
in the PM
"
::= { pmdgeCtrlsynth4 2 }
pmdgeCtrlCorrelatOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Enable Alarm Correlation :This
OID enables the alarm correlation
in the PM
"
::= { pmdgeCtrlsynth4 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pmdgeCtrlswMgnt OBJECT IDENTIFIER ::= { pmdgeCtrlOther 5 }
pmdgeCtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Software Warm Reset :This OID,
when set, causes a warm reset of
the Software. This reset is not
traffic affecting, and the configuration
of the Sofwtare remains unchanged.
<Help> This control initiates
a warm reset of the module.
"
::= { pmdgeCtrlswMgnt 3 }
pmdgeCtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Software Cold Reset :This OID,
when set, causes a cold reset of
the Software. This reset is traffic
affecting, and the configuration
of Software is reloaded on start-up.
<Help> This control initiates
a cold reset of the module.
"
::= { pmdgeCtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the switchCtrl article
--- *****************************************************
pmdgeCtrlswitchCtrl OBJECT IDENTIFIER ::= { pmdgeCtrlOther 16 }
pmdgeCtrlAllChannelsHighLoss OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Equalizer Shutdown :This OID ,
when set, puts all the waves on
a high attenuation mode. <Help>
This control sets the waves on
a high attenuation mode
"
::= { pmdgeCtrlswitchCtrl 1 }
--- *****************************************************
--- LEAF for the craftSynch article
--- *****************************************************
pmdgeCtrlcraftSynch OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Craft Synchro :This OID is used
for internal purpose only
"
::= { pmdgeCtrlOther 17 }
--- *********************************************************
--- TABLE for the pmdgeCtrlequTxCommonAttDeg articles
--- *********************************************************
pmdgeCtrlequTxCommonAttDegTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmdgeCtrlequTxCommonAttDegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pmdgeCtrlequTxCommonAttDeg
Article
"
::= { pmdgeCtrlEqualizer 19 }
pmdgeCtrlequTxCommonAttDegEntry OBJECT-TYPE
SYNTAX PmdgeCtrlequTxCommonAttDegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pmdgeCtrlequTxCommonAttDeg
table
"
INDEX { pmdgeCtrlequTxCommonAttDegIndex }
::= { pmdgeCtrlequTxCommonAttDegTable 1 }
PmdgeCtrlequTxCommonAttDegEntry ::=
SEQUENCE {
pmdgeCtrlequTxCommonAttDegIndex
INTEGER,
pmdgeCtrlequTxCommonAttDegPortn
INTEGER
}
pmdgeCtrlequTxCommonAttDegIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pmdgeCtrlequTxCommonAttDeg
table
"
::= { pmdgeCtrlequTxCommonAttDegEntry 1 }
pmdgeCtrlequTxCommonAttDegPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Equalizer Output Attenuation :This
OID defines the line output attenuation.
<Help> This OID defines the
line output attenuation
"
::= { pmdgeCtrlequTxCommonAttDegEntry 2 }
--- *****************************************************
--- LEAF for the applyPlanUpdate article
--- *****************************************************
pmdgeCtrlapplyPlanUpdate OBJECT IDENTIFIER ::= { pmdgeCtrlEqualizer 44 }
pmdgeCtrlApply OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Apply Update :This OID confirms
the parameters selected for the
waveplan modification
"
::= { pmdgeCtrlapplyPlanUpdate 1 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pmdgeCtrlledTest OBJECT IDENTIFIER ::= { pmdgeCtrlOther 64 }
pmdgeCtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pmdgeCtrlledTest 3 }
pmdgeCtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pmdgeCtrlledTest 2 }
pmdgeCtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pmdgeCtrlledTest 1 }
--- *********************************************************
--- TABLE for the pmdgeCtrlwavePlanAssignmentsRefresh articles
--- *********************************************************
pmdgeCtrlwavePlanAssignmentsRefreshTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmdgeCtrlwavePlanAssignmentsRefreshEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pmdgeCtrlwavePlanAssignmentsRefresh
Article
"
::= { pmdgeCtrlOther 65 }
pmdgeCtrlwavePlanAssignmentsRefreshEntry OBJECT-TYPE
SYNTAX PmdgeCtrlwavePlanAssignmentsRefreshEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pmdgeCtrlwavePlanAssignmentsRefresh
table
"
INDEX { pmdgeCtrlwavePlanAssignmentsRefreshIndex }
::= { pmdgeCtrlwavePlanAssignmentsRefreshTable 1 }
PmdgeCtrlwavePlanAssignmentsRefreshEntry ::=
SEQUENCE {
pmdgeCtrlwavePlanAssignmentsRefreshIndex
INTEGER,
pmdgeCtrlWaveStatusRefreshPortn
EkiOnOff,
pmdgeCtrlWaveNarrowingRefreshPortn
INTEGER,
pmdgeCtrlWaveCenterFrequencyRefreshPortn
INTEGER,
pmdgeCtrlWaveOOSRefreshPortn
EkiOnOff,
pmdgeCtrlWaveAttenuationRefreshPortn
INTEGER,
pmdgeCtrlWaveItuRefreshPortn
DisplayString,
pmdgeCtrlWaveDegreeRefreshPortn
INTEGER,
pmdgeCtrlUsageRefreshPortn
EkiOnOff
}
pmdgeCtrlwavePlanAssignmentsRefreshIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pmdgeCtrlwavePlanAssignmentsRefresh
table
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 1 }
pmdgeCtrlWaveStatusRefreshPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
WaveStatus :This OID sets the
waves status to ON or OFF inside
the waveplan.
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 2 }
pmdgeCtrlWaveNarrowingRefreshPortn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
WaveNarrowing :This OID sets
the wave narrowing value inside
the waveplan (Not Used)
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 3 }
pmdgeCtrlWaveCenterFrequencyRefreshPortn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
WaveCenterFrequency :This OID
sets the wave center frequency
value inside the waveplan (Not
Used)
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 4 }
pmdgeCtrlWaveOOSRefreshPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
WaveOOS :This OID sets the wave
Out Of Service value inside the
waveplan (Not Used)
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 5 }
pmdgeCtrlWaveAttenuationRefreshPortn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
WaveAttenuation :This OID sets
the wave attenuation value inside
the waveplan.
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 6 }
pmdgeCtrlWaveItuRefreshPortn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
WaveItu :This OID sets the wave
channel number inside the waveplan
(Not Used)
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 7 }
pmdgeCtrlWaveDegreeRefreshPortn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
WaveDegree :This OID sets the
degree assigned to the wave inside
the waveplan (Not Used)
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 8 }
pmdgeCtrlUsageRefreshPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Wave Assignment :This OID gives
the assignment of a wave for a
given waveplan along with the
full possible waveplan.
"
::= { pmdgeCtrlwavePlanAssignmentsRefreshEntry 16 }
--- *********************************************************
--- TABLE for the pmdgeCtrlwavePlanAssignmentsWork articles
--- *********************************************************
pmdgeCtrlwavePlanAssignmentsWorkTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmdgeCtrlwavePlanAssignmentsWorkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pmdgeCtrlwavePlanAssignmentsWork
Article
"
::= { pmdgeCtrlOther 66 }
pmdgeCtrlwavePlanAssignmentsWorkEntry OBJECT-TYPE
SYNTAX PmdgeCtrlwavePlanAssignmentsWorkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pmdgeCtrlwavePlanAssignmentsWork
table
"
INDEX { pmdgeCtrlwavePlanAssignmentsWorkIndex }
::= { pmdgeCtrlwavePlanAssignmentsWorkTable 1 }
PmdgeCtrlwavePlanAssignmentsWorkEntry ::=
SEQUENCE {
pmdgeCtrlwavePlanAssignmentsWorkIndex
INTEGER,
pmdgeCtrlWaveStatusWorkPortn
EkiOnOff,
pmdgeCtrlWaveNarrowingWorkPortn
INTEGER,
pmdgeCtrlWaveCenterFrequencyWorkPortn
INTEGER,
pmdgeCtrlWaveOOSWorkPortn
EkiOnOff,
pmdgeCtrlWaveAttenuationWorkPortn
INTEGER,
pmdgeCtrlWaveItuWorkPortn
DisplayString,
pmdgeCtrlWaveDegreeWorkPortn
INTEGER,
pmdgeCtrlUsageWorkPortn
EkiOnOff
}
pmdgeCtrlwavePlanAssignmentsWorkIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pmdgeCtrlwavePlanAssignmentsWork
table
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 1 }
pmdgeCtrlWaveStatusWorkPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
WaveStatus :This OID sets the
waves status to ON or OFF inside
the waveplan.
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 2 }
pmdgeCtrlWaveNarrowingWorkPortn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
WaveNarrowing :This OID sets
the wave narrowing value inside
the waveplan (Not Used)
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 3 }
pmdgeCtrlWaveCenterFrequencyWorkPortn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
WaveCenterFrequency :This OID
sets the wave center frequency
value inside the waveplan (Not
Used)
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 4 }
pmdgeCtrlWaveOOSWorkPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
WaveOOS :This OID sets the wave
Out Of Service value inside the
waveplan (Not Used)
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 5 }
pmdgeCtrlWaveAttenuationWorkPortn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
WaveAttenuation :This OID sets
the wave attenuation value inside
the waveplan.
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 6 }
pmdgeCtrlWaveItuWorkPortn OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
WaveItu :This OID sets the wave
channel number inside the waveplan
(Not Used)
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 7 }
pmdgeCtrlWaveDegreeWorkPortn OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
WaveDegree :This OID sets the
degree assigned to the wave inside
the waveplan (Not Used)
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 8 }
pmdgeCtrlUsageWorkPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Wave Assignment :This OID gives
the assignment of a wave for a
given waveplan along with the
full possible waveplan.
"
::= { pmdgeCtrlwavePlanAssignmentsWorkEntry 16 }
--- *****************************************************
--- LEAF for the buildFromMgntPlan article
--- *****************************************************
pmdgeCtrlbuildFromMgntPlan OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Build From MGNT :This OID builds
a waveplan from the waveplans stored
in the MGNT board. <Help> This
control builds a waveplan from
the waveplans stored in the MGNT
board.
"
::= { pmdgeCtrlOther 67 }
--- *****************************************************
--- LEAF for the loadToWorkplan article
--- *****************************************************
pmdgeCtrlloadToWorkplan OBJECT-TYPE
SYNTAX PmdgePlanNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Display Waveplan :This OID displays
in the user interface one of the
following waveplan : In service
Waveplan, Saved Waveplan 1, Saved
Waveplan 2, Build from MGNT Waveplan.
<Help> This control displays
in the user interface one of the
following waveplan : In service
Waveplan, Saved Waveplan 1, Saved
Waveplan 2, Build from MGNT Waveplan.
"
::= { pmdgeCtrlOther 68 }
--- *****************************************************
--- LEAF for the saveWorkPlanTo article
--- *****************************************************
pmdgeCtrlsaveWorkPlanTo OBJECT-TYPE
SYNTAX PmdgePlanNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Save Waveplan : This OID saves
(in the Saved Waveplan 1 or Saved
Waveplan 2) the waveplan built
with the user interface. <Help>
This control saves (in the Saved
Waveplan 1 or Saved Waveplan 2)
the waveplan displayed with the
user interface.
"
::= { pmdgeCtrlOther 69 }
--- *****************************************************
--- LEAF for the loadPlanToUse article
--- *****************************************************
pmdgeCtrlloadPlanToUse OBJECT-TYPE
SYNTAX PmdgePlanNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Waveplan In Service : This
OID sets on the following waveplan
In Service (Saved Waveplan 1, Saved
Waveplan 2 or Displayed Waveplan).
<Help> This control sets on the
following waveplan In Service (Saved
Waveplan 1, Saved Waveplan 2 or
Displayed Waveplan).
"
::= { pmdgeCtrlOther 70 }
--- *****************************************************
--- LEAF for the refreshWithPlan article
--- *****************************************************
pmdgeCtrlrefreshWithPlan OBJECT-TYPE
SYNTAX PmdgePlanNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Refresh User Interface :This OID
refreshes the user interface with
the information coming from the
In service Waveplan, the Saved
Waveplan 1 or the Saved Waveplan
2. <Help> This control refreshes
the user interface with the information
coming from the In service Waveplan,
the Saved Waveplan 1 or the Saved
Waveplan 2.
"
::= { pmdgeCtrlOther 71 }
--- *****************************************************
--- LEAF for the savePlanToFile article
--- *****************************************************
pmdgeCtrlsavePlanToFile OBJECT-TYPE
SYNTAX PmdgePlanNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Export To File On MGNT :This OID
exports the Displayed Waveplan
to a file on the MGNT board.
<Help> This control the Displayed
waveplan to a file on the MGNT
board.
"
::= { pmdgeCtrlOther 72 }
--- *****************************************************
--- LEAF for the loadPlanFromFile article
--- *****************************************************
pmdgeCtrlloadPlanFromFile OBJECT-TYPE
SYNTAX PmdgePlanNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Import From File On MGNT :This
OID imports a waveplan from a file
on the MGNT board to the Displayed
Waveplan. <Help> This control
imports a waveplan from a file
on the MGNT board to the Displayed
Waveplan.
"
::= { pmdgeCtrlOther 73 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the switchTemp article
--- *****************************************************
pmdgeMesrswitchTemp OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Equalizer Temperature :This OID
gives the temperature value of
the switch in the module (Temperature
= AV/256) (Unit = C) <Help>
This measure gives the temperature
value of the switch in the module
"
::= { pmdgeMesrOther 16 }
--- *****************************************************
--- LEAF for the moduleTemp article
--- *****************************************************
pmdgeMesrmoduleTemp OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature :This OID gives
the temperature value of the module
(Temperature = AV/256) (Unit =
C) <Help> This measure gives
the temperature value of the module
"
::= { pmdgeMesrOther 64 }
--- *****************************************************
--- LEAF for the caseTemp article
--- *****************************************************
pmdgeMesrcaseTemp OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Case Temperature :This OID gives
the temperature value of the case
of the module (Temperature = AV/256)
(Unit = C) <Help> This measure
gives the temperature value of
the case of the module
"
::= { pmdgeMesrOther 65 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group lsd
--- *****************************************************
pmdgeCfgLsd OBJECT IDENTIFIER ::= { pmdgeConfig 1 }
--- *****************************************************
--- LEAF for the table 0012
--- *****************************************************
pmdgetableclientLsd OBJECT IDENTIFIER ::= { pmdgeCfgLsd 1 }
--- *****************************************************
--- LEAF for the table Group startup
--- *****************************************************
pmdgeCfgStartup OBJECT IDENTIFIER ::= { pmdgeConfig 2 }
--- *****************************************************
--- LEAF for the table 2111
--- *****************************************************
pmdgeCfgClientStartupTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmdgeCfgClientStartupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmdgeCfgStartup 1 }
pmdgeCfgClientStartupEntry OBJECT-TYPE
SYNTAX PmdgeCfgClientStartupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the startup
table
"
INDEX { pmdgeCfgClientStartupIndex }
::= { pmdgeCfgClientStartupTable 1 }
PmdgeCfgClientStartupEntry ::=
SEQUENCE {
pmdgeCfgClientStartupIndex
INTEGER,
pmdgeCfgLineaRxCommonAttDegPortn
Unsigned32
}
pmdgeCfgClientStartupIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the clientStartup
table
"
::= { pmdgeCfgClientStartupEntry 1 }
pmdgeCfgLineaRxCommonAttDegPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Defaut setting on attenuation
on Rx Express :This register selects
the Rx attenuator value of the
Express line on setup
"
::= { pmdgeCfgClientStartupEntry 3 }
--- *****************************************************
--- LEAF for the table 2191
--- *****************************************************
pmdgetablelineStartup OBJECT IDENTIFIER ::= { pmdgeCfgStartup 2 }
--- *****************************************************
--- LEAF for the table 2511
--- *****************************************************
pmdgetableclientsDge OBJECT IDENTIFIER ::= { pmdgeCfgStartup 3 }
--- *****************************************************
--- LEAF for the table 2591
--- *****************************************************
pmdgetablelinesDge OBJECT IDENTIFIER ::= { pmdgeCfgStartup 4 }
pmdgeCfgequGridCurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default setting of the grid :This
register selects the configuration
of the grid used on setup
"
::= { pmdgetablelinesDge 2 }
--- *****************************************************
--- LEAF for the table 0005
--- *****************************************************
pmdgetableother OBJECT IDENTIFIER ::= { pmdgeCfgStartup 5 }
pmdgeCfgcomponentType OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Component parameters :This OID
defines the component parameters
"
::= { pmdgetableother 2 }
pmdgeCfgmiscellaneous OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Miscellaneous default settings
:This OID defines the miscellaneous
parameters
"
::= { pmdgetableother 3 }
pmdgeCfgfirstChannel OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Number of the first channel of
the component :This OID defines
the first channel number of the
PM
"
::= { pmdgetableother 4 }
pmdgeCfglastChannel OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Number of the last channel of
the component :This OID defines
the last channel number of the
PM
"
::= { pmdgetableother 5 }
pmdgeCfggrid OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Grid value of the component :This
OID defines the grid of the PM
"
::= { pmdgetableother 6 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pmdgeCfgLabels OBJECT IDENTIFIER ::= { pmdgeConfig 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmdgeCfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmdgeCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmdgeCfgLabels 1 }
pmdgeCfgLabelclientEntry OBJECT-TYPE
SYNTAX PmdgeCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmdgeCfgLabelclientIndex }
::= { pmdgeCfgLabelclientTable 1 }
PmdgeCfgLabelclientEntry ::=
SEQUENCE {
pmdgeCfgLabelclientIndex
INTEGER,
pmdgeCfgLabelclientPortn
DisplayString
}
pmdgeCfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pmdgeCfgLabelclientEntry 1 }
pmdgeCfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pmdgeCfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmdgeCfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmdgeCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmdgeCfgLabels 2 }
pmdgeCfgLabellineEntry OBJECT-TYPE
SYNTAX PmdgeCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmdgeCfgLabellineIndex }
::= { pmdgeCfgLabellineTable 1 }
PmdgeCfgLabellineEntry ::=
SEQUENCE {
pmdgeCfgLabellineIndex
INTEGER,
pmdgeCfgLabellinePortn
DisplayString
}
pmdgeCfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pmdgeCfgLabellineEntry 1 }
pmdgeCfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pmdgeCfgLabellineEntry 3 }
pmdgeCfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pmdgeConfig 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pmdgetrapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pmdgetraps 4 }
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pmdgePowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmdgeAlmDefFuseB, pmdgeAlmDefFuseA , pmdgetrapBoardNumber}
STATUS current
DESCRIPTION "Urgent power supply default is activated"
::= { pmdgetraps 50 }
pmdgePowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmdgeAlmDefFuseB, pmdgeAlmDefFuseA , pmdgetrapBoardNumber}
STATUS current
DESCRIPTION "Urgent power supply default disappeared"
::= { pmdgetraps 51 }
END