Observium_CE/mibs/ekinops/EKINOPS-Pm200frs02-MIB

13879 lines
378 KiB
Plaintext

-- *****************************************************************
-- EKINOPS-Pm200frs02.TXT: MIB
--
--MIB Part Number:3MI00050AAAB
--MIB Version:01
--
-- Copyright (c) 2017 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-Pm200frs02-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulePm200frs02 MODULE-IDENTITY
LAST-UPDATED "201709150000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.fr"
DESCRIPTION
"Creation."
REVISION "201707250000Z"
DESCRIPTION
"Creation for PM200FRS02"
REVISION "201709150000Z"
DESCRIPTION
"Adding Alarm Objects"
::= { ekinops 90 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pm200frs02alarms OBJECT IDENTIFIER ::= { modulePm200frs02 2 }
pm200frs02AlmOther OBJECT IDENTIFIER ::= { pm200frs02alarms 1 }
pm200frs02AlmOtherNurg OBJECT IDENTIFIER ::= { pm200frs02AlmOther 1 }
pm200frs02AlmOtherUrg OBJECT IDENTIFIER ::= { pm200frs02AlmOther 2 }
pm200frs02AlmOtherCrit OBJECT IDENTIFIER ::= { pm200frs02AlmOther 3 }
pm200frs02AlmClient OBJECT IDENTIFIER ::= { pm200frs02alarms 2 }
pm200frs02AlmClientNurg OBJECT IDENTIFIER ::= { pm200frs02AlmClient 1 }
pm200frs02AlmClientUrg OBJECT IDENTIFIER ::= { pm200frs02AlmClient 2 }
pm200frs02AlmClientCrit OBJECT IDENTIFIER ::= { pm200frs02AlmClient 3 }
pm200frs02AlmLine OBJECT IDENTIFIER ::= { pm200frs02alarms 3 }
pm200frs02AlmLineNurg OBJECT IDENTIFIER ::= { pm200frs02AlmLine 1 }
pm200frs02AlmLineUrg OBJECT IDENTIFIER ::= { pm200frs02AlmLine 2 }
pm200frs02AlmLineCrit OBJECT IDENTIFIER ::= { pm200frs02AlmLine 3 }
pm200frs02measures OBJECT IDENTIFIER ::= { modulePm200frs02 3 }
pm200frs02MesrOther OBJECT IDENTIFIER ::= { pm200frs02measures 1 }
pm200frs02MesrClient OBJECT IDENTIFIER ::= { pm200frs02measures 2 }
pm200frs02MesrLine OBJECT IDENTIFIER ::= { pm200frs02measures 3 }
pm200frs02counters OBJECT IDENTIFIER ::= { modulePm200frs02 4 }
pm200frs02CntOther OBJECT IDENTIFIER ::= { pm200frs02counters 1 }
pm200frs02CntClient OBJECT IDENTIFIER ::= { pm200frs02counters 2 }
pm200frs02CntLine OBJECT IDENTIFIER ::= { pm200frs02counters 3 }
pm200frs02controlsWrite OBJECT IDENTIFIER ::= { modulePm200frs02 6 }
pm200frs02CtrlOther OBJECT IDENTIFIER ::= { pm200frs02controlsWrite 1 }
pm200frs02CtrlClient OBJECT IDENTIFIER ::= { pm200frs02controlsWrite 2 }
pm200frs02CtrlLine OBJECT IDENTIFIER ::= { pm200frs02controlsWrite 3 }
pm200frs02ri OBJECT IDENTIFIER ::= { modulePm200frs02 7 }
pm200frs02riTable OBJECT IDENTIFIER ::= { pm200frs02ri 1 }
pm200frs02download OBJECT IDENTIFIER ::= { modulePm200frs02 8 }
pm200frs02DwlOther OBJECT IDENTIFIER ::= { pm200frs02download 1 }
pm200frs02DwlClient OBJECT IDENTIFIER ::= { pm200frs02download 2 }
pm200frs02DwlLine OBJECT IDENTIFIER ::= { pm200frs02download 3 }
pm200frs02Config OBJECT IDENTIFIER ::= { modulePm200frs02 9 }
pm200frs02traps OBJECT IDENTIFIER ::= { modulePm200frs02 10 }
pm200frs02Monitoring OBJECT IDENTIFIER ::= { modulePm200frs02 11}
pm200frs02MonOther OBJECT IDENTIFIER ::= { pm200frs02Monitoring 1 }
pm200frs02MonRmon OBJECT IDENTIFIER ::= { pm200frs02MonOther 3 }
pm200frs02MonClient OBJECT IDENTIFIER ::= { pm200frs02Monitoring 2 }
pm200frs02MonClientRmonCounter OBJECT IDENTIFIER ::= { pm200frs02MonClient 4 }
pm200frs02MonPerfOther OBJECT IDENTIFIER ::= { pm200frs02Monitoring 5 }
pm200frs02MonPerfSync OBJECT IDENTIFIER ::= { pm200frs02MonPerfOther 1 }
pm200frs02MonPerfTimeStamp OBJECT IDENTIFIER ::= { pm200frs02MonPerfOther 2 }
pm200frs02MonPerfClient OBJECT IDENTIFIER ::= { pm200frs02Monitoring 6 }
pm200frs02MonPerfLine OBJECT IDENTIFIER ::= { pm200frs02Monitoring 7 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
Pm200frs02MultiRate ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "different rate for a client port"
SYNTAX INTEGER {
rate100Mhz(0),
rate250Mhz(1),
rate500Mhz(2),
rate1Ghz(3)
}
Pm200frs02OtxMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on OTX-TLH on client and line ports"
SYNTAX INTEGER {
otx80mode(1),
otx60mode(2),
otxadjustmode(4)
}
Pm200frs02OtxGrid ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different grids on OTX-TLH on client and line ports"
SYNTAX INTEGER {
otxgrid200(200),
otxgrid100(100),
otxgrid50(50)
}
Pm200frs02AdjustValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different values in Adjust mode on OTX-TLH on client and line ports"
SYNTAX INTEGER {
otxadjustvalue0(0),
otxadjustvalue1(1),
otxadjustvalue2(2),
otxadjustvalue3(3),
otxadjustvalue4(4),
otxadjustvalue5(5),
otxadjustvalue6(6),
otxadjustvalue7(7),
otxadjustvalue8(8),
otxadjustvalue9(9),
otxadjustvalue10(10)
}
Pm200frs02ClientProtocol ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different values on the protocol on the client ports"
SYNTAX INTEGER {
protocolclientvalue0(0),
protocolclientvalue1(1),
protocolclientvalue2(2),
protocolclientvalue3(3),
protocolclientvalue4(4),
protocolclientvalue5(5),
protocolclientvalue6(6),
protocolclientvalue7(7),
protocolclientvalue8(8)
}
Pm200frs02ModuleMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different values on the module mode"
SYNTAX INTEGER {
modulemodevalue0(0),
modulemodevalue1(1),
modulemodevalue2(2),
modulemodevalue3(3),
modulemodevalue4(4),
modulemodevalue5(5)
}
Pm200frs02OtxChannel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Channel selection on transceiver Tx line ports"
SYNTAX INTEGER
Pm200frs02OrxChannel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Channel selection on transceiver Rx line ports"
SYNTAX INTEGER
Pm200frs02DccMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Mode for DCC"
SYNTAX INTEGER {
dccNo(0),
dccLine1(1),
dccLine2(2)
}
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pm200frs02RinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pm200frs02ri 2 }
pm200frs02RinvHwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HW platform description: This OID contains the
description of the Hardware platform."
::= { pm200frs02ri 3 }
pm200frs02RinvModulePlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pm200frs02ri 4 }
pm200frs02RinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pm200frs02ri 5 }
pm200frs02RinvGwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GW platform description: This OID contains the
description of the Gateware platform."
::= { pm200frs02ri 6 }
pm200frs02RinvSfpTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02RinvSfpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the SFPs on the selected module"
::= { pm200frs02riTable 1 }
pm200frs02RinvSfpEntry OBJECT-TYPE
SYNTAX Pm200frs02RinvSfpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the SFP table"
INDEX { pm200frs02RinvSfpIndex }
::= { pm200frs02RinvSfpTable 1 }
Pm200frs02RinvSfpEntry::=
SEQUENCE {
pm200frs02RinvSfpIndex
Integer32,
pm200frs02Rinvsfp
DisplayString
}
pm200frs02RinvSfpIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for SFP table"
::= { pm200frs02RinvSfpEntry 1 }
pm200frs02Rinvsfp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the SFP: This OID contains the inventory for the SFP"
::= { pm200frs02RinvSfpEntry 2 }
pm200frs02RinvLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02RinvLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the XFPs on the selected module"
::= { pm200frs02riTable 2 }
pm200frs02RinvLineEntry OBJECT-TYPE
SYNTAX Pm200frs02RinvLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the XFP table"
INDEX { pm200frs02RinvLineIndex }
::= { pm200frs02RinvLineTable 1 }
Pm200frs02RinvLineEntry::=
SEQUENCE {
pm200frs02RinvLineIndex
Integer32,
pm200frs02RinvxfpLine
DisplayString
}
pm200frs02RinvLineIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for XFP table"
::= { pm200frs02RinvLineEntry 1 }
pm200frs02RinvxfpLine OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the XFP: This OID contains the inventory for the XFP"
::= { pm200frs02RinvLineEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pm200frs02AlmsynthAlm0 OBJECT IDENTIFIER ::= { pm200frs02AlmOtherCrit 0 }
pm200frs02AlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help> Status
of the Fuse B <Condtype> DEF_FUSE_B
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlm0 16 }
pm200frs02AlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help> Status
of the Fuse A <Condtype> DEF_FUSE_A
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlm0 15 }
pm200frs02AlmModGlobFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the RM <Help> This alarm is
set on detection of a failure originating
from the equipment <Condtype> MOD_GLOB_FAIL
<Probcause> other (1) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlm0 9 }
pm200frs02AlmFailFan OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fan Fail :This OID is at 1 when
any fail occurs on the fan tray
<Help> This alarm indicates that
the Fan tray module is in a failure
condition <Condtype> FAIL_FAN <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlm0 2 }
--- *****************************************************
--- LEAF for the synthAlm2 article
--- *****************************************************
pm200frs02AlmsynthAlm2 OBJECT IDENTIFIER ::= { pm200frs02AlmOtherNurg 2 }
pm200frs02AlmMaintenanceOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Maintenance Mode :This OID indicates
that the RM is in maintenance mode.
<Help> This alarm indicates that
the maintenance mode is enabled
on the PM <Condtype> MAINTENANCE_ON
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlm2 5 }
pm200frs02AlmCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Not Used :This OID, when set,
indicates that alarm correlation
is not being performed. <Condtype>
CORRELAT_OFF <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlm2 4 }
pm200frs02AlmConfTableLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Load :This OID
is at 1 during the loading of
configuration tables in the modules
RAM. <Condtype> CONF_TABLE_LOAD
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlm2 3 }
pm200frs02AlmInvUpload OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Inventory Upload :This OID is
at 1 during the uploading of PM
inventory information. <Condtype>
INV_UPLOAD <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlm2 2 }
pm200frs02AlmConfTableSave OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Save :This OID
is at 1 during the saving of a
new configuration table in the
module Flash memory. <Condtype>
CONF_TABLE_SAVE <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlm2 1 }
--- *********************************************************
--- TABLE for the pm200frs02AlmsynthAlmPort articles
--- *********************************************************
pm200frs02AlmsynthAlmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02AlmsynthAlmPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02AlmsynthAlmPort
Article
"
::= { pm200frs02AlmClientCrit 8 }
pm200frs02AlmsynthAlmPortEntry OBJECT-TYPE
SYNTAX Pm200frs02AlmsynthAlmPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02AlmsynthAlmPort
table
"
INDEX { pm200frs02AlmsynthAlmPortIndex }
::= { pm200frs02AlmsynthAlmPortTable 1 }
Pm200frs02AlmsynthAlmPortEntry ::=
SEQUENCE {
pm200frs02AlmsynthAlmPortIndex
INTEGER,
pm200frs02AlmUpCsfPortn
EkiOnOff,
pm200frs02AlmFailAccPortn
EkiOnOff,
pm200frs02AlmSfpDdmAlmPortn
EkiOnOff,
pm200frs02AlmSfpDdmWarningPortn
EkiOnOff,
pm200frs02AlmDwCaisPortn
EkiOnOff,
pm200frs02AlmClientRemoteOosPortn
EkiOnOff,
pm200frs02AlmClientLocalOosPortn
EkiOnOff,
pm200frs02AlmDwLsdPortn
EkiOnOff,
pm200frs02AlmHwFailAccPortn
EkiOnOff,
pm200frs02AlmDdmAbsentPortn
EkiOnOff,
pm200frs02AlmSfpAbsentPortn
EkiOnOff
}
pm200frs02AlmsynthAlmPortIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02AlmsynthAlmPort
table
"
::= { pm200frs02AlmsynthAlmPortEntry 1 }
pm200frs02AlmUpCsfPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Signal Fail Inserted :This
OID indicates a CSF has been inserted
in the upstream client port. <Help>
This status indicates if a Client
Signal Fail is currently inserted
on the line signal for this client
port <Condtype> UP_CSF_1 <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmPortEntry 17 }
pm200frs02AlmFailAccPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Access Fail :This OID indicates
a failure on the Client port <Help>
This alarm indicates a failure
on the Client port <Condtype>
FAIL_ACC_1 <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmPortEntry 13 }
pm200frs02AlmSfpDdmAlmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Client Trscv DDM :This
OID indicates an alarm is being
received from the Client Transceiver
DDM <Help> This alarm indicates
if a DDM Alarm has been detected
on the client transceiver <Condtype>
SFP_DDM_ALM_1 <Probcause> inputOutputDeviceError
(24) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmPortEntry 11 }
pm200frs02AlmSfpDdmWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Client Trscv DDM :This
OID indicates a warning is being
received from the Client Transceiver
DDM <Help> This alarm indicates
if a DDM Warning has been detected
on the client transceiver <Condtype>
SFP_DDM_WARNING_1 <Probcause> inputOutputDeviceError
(24) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmPortEntry 10 }
pm200frs02AlmDwCaisPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client AIS Inserted :This OID
indicates a CAIS has been inserted
on the output client port. <Help>
This status indicates if a Client
Alarm Indication Signal is currently
inserted on the client interface
<Condtype> DW_CAIS_1 <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmPortEntry 9 }
pm200frs02AlmClientRemoteOosPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Remote Client Port In Service
:This OID indicates that the remote
Client port is In Service (1) or
Out of Service (2) <Help> This
status indicates if the remote
client port is in service <Condtype>
CLIENT_REMOTE_OOS <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlmPortEntry 8 }
pm200frs02AlmClientLocalOosPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Local Client Port In Service :This
OID indicates that the local Client
port is In Service (1) or Out of
Service (2) <Help> This status
indicates if the local client
port is in service <Condtype>
CLIENT_LOCAL_OOS <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlmPortEntry 7 }
pm200frs02AlmDwLsdPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Trscv Laser Shutdown :This
OID indicates the Client transceiver
laser is shutdown <Help> This status
indicates if the client transceiver
laser is shutdown <Condtype> DW_LSD_1
<Probcause> other (1) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmPortEntry 6 }
pm200frs02AlmHwFailAccPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client HW Fail :This OID indicates
a failure on client port, most
probably caused by a HW issue.
<Help> This alarm indicates a failure
on client port, most probably caused
by a HW issue. <Condtype> HW_FAIL_ACC_1
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmPortEntry 5 }
pm200frs02AlmDdmAbsentPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
DDM Supported On Client Trscv
:This OID indicates that the Client
transceiver supports the Digital
Diagnostic Monitoring function
<Help> This status indicates if
the client transceiver includes
the DDM feature <Condtype> DDM_ABSENT_1
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmsynthAlmPortEntry 3 }
pm200frs02AlmSfpAbsentPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Optical Module Absent :This
OID indicates that the Transceiver
is not present in the client port.
<Help> This alarm indicates if
the client transceiver is not
plugged <Condtype> SFP_ABSENT_1
<Probcause> inputOutputDeviceError
(24) <Alarmtype> equipmentAlarm
(5) <Polarity> (2) <Event> ObjectCDSingleClientInv
"
::= { pm200frs02AlmsynthAlmPortEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02AlmsynthAlmLine articles
--- *********************************************************
pm200frs02AlmsynthAlmLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02AlmsynthAlmLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02AlmsynthAlmLine
Article
"
::= { pm200frs02AlmLineCrit 40 }
pm200frs02AlmsynthAlmLineEntry OBJECT-TYPE
SYNTAX Pm200frs02AlmsynthAlmLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02AlmsynthAlmLine
table
"
INDEX { pm200frs02AlmsynthAlmLineIndex }
::= { pm200frs02AlmsynthAlmLineTable 1 }
Pm200frs02AlmsynthAlmLineEntry ::=
SEQUENCE {
pm200frs02AlmsynthAlmLineIndex
INTEGER,
pm200frs02AlmLineActivePortn
EkiOnOff,
pm200frs02AlmLineFailPortn
EkiOnOff,
pm200frs02AlmLineDdmAlmPortn
EkiOnOff,
pm200frs02AlmLineDdmWarningPortn
EkiOnOff,
pm200frs02AlmUpRdiInsPortn
EkiOnOff,
pm200frs02AlmLineLocalOosPortn
EkiOnOff,
pm200frs02AlmXfpTxOffPortn
EkiOnOff,
pm200frs02AlmLineHwFailPortn
EkiOnOff,
pm200frs02AlmXfpInitNotComplPortn
EkiOnOff,
pm200frs02AlmXfpAbsentPortn
EkiOnOff
}
pm200frs02AlmsynthAlmLineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02AlmsynthAlmLine
table
"
::= { pm200frs02AlmsynthAlmLineEntry 1 }
pm200frs02AlmLineActivePortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Active :This OID indicates
whether the line is active or standby.
<Help> This status indicates whether
the line is active or standby.
<Condtype> LINE_ACTIVE <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 17 }
pm200frs02AlmLineFailPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port Failure :This OID indicates
a failure on the line port <Help>
This alarm indicates a failure
on the line port <Condtype> LINE_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 13 }
pm200frs02AlmLineDdmAlmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Line Optical Module DDM
:This OID indicates an alarm is
present coming out of Line transceiver
DDM <Help> This alarm indicates
if a DDM Alarm has been detected
on the line transceiver <Condtype>
LINE_DDM_ALM <Probcause> inputOutputDeviceError
(24) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 11 }
pm200frs02AlmLineDdmWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Line Optical Module
DDM :This OID indicates a warning
is present coming out of Line transceiver
DDM <Help> This alarm indicates
if a DDM Warning has been detected
on the line transceiver <Condtype>
LINE_DDM_WARNING <Probcause> inputOutputDeviceError
(24) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 10 }
pm200frs02AlmUpRdiInsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
MS-RDI/L-RDI Inserted On Line
:This OID indicates an upstream
MS-RDI/L-RDI has been inserted
in the outgoing 10 Gb/s SDH/SONET
signal. <Help> This status indicates
if a MS-RDI/L-RDI is currently
inserted on the line interface.
<Condtype> UP_RDI_INS <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 9 }
pm200frs02AlmLineLocalOosPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port In Service :This OID
indicates that the Line port is
In Service (1) of Out or Service
(2) <Help> This status indicates
if the line port is in service
<Condtype> LINE_LOCAL_OOS <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 7 }
pm200frs02AlmXfpTxOffPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Laser Shutdown :This
OID indicates the Line transceiver
laser is shutdown <Help> This status
indicates if the Line transceiver
laser is shutdown <Condtype> XFP_TX_OFF
<Probcause> other (1) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 6 }
pm200frs02AlmLineHwFailPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Help> This alarm indicates a failure
on line port, most probably caused
by a HW issue <Condtype> LINE_HW_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 5 }
pm200frs02AlmXfpInitNotComplPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Optical Module Ready :This
OID indicates that the optical
interface is not operational.
<Help> This status indicates if
the line transceiver has been correctly
initialized <Condtype> XFP_INIT_NOT_COMPL
<Probcause> equipmentMalfunction
(16) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 3 }
pm200frs02AlmXfpAbsentPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Optical Module Absent :This
OID indicates that the line optical
interface is not present. <Help>
This alarm indicates if the line
transceiver is not plugged <Condtype>
XFP_ABSENT <Probcause> inputOutputDeviceError
(24) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmsynthAlmLineEntry 2 }
--- *****************************************************
--- LEAF for the msaModuleState article
--- *****************************************************
pm200frs02AlmmsaModuleState OBJECT IDENTIFIER ::= { pm200frs02AlmOtherCrit 78 }
pm200frs02AlmMsaHighPowerDown OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv High Power Down :This
OID indicates the Line Trscv is
entering Low Power state <Help>
Status indicating the Line Trscv
is entering Low Power state <Condtype>
MSA_HIGH_POWER_DOWN <Probcause>
informationalStatus(1000) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pm200frs02AlmmsaModuleState 9 }
pm200frs02AlmMsaTxTurnOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Laser Turn Off :This
OID indicates the Line Trscv is
turning off its laser <Help> Status
indicating the Line Trscv is turning
off its laser <Condtype> MSA_TX_TURN_OFF
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmmsaModuleState 8 }
pm200frs02AlmMsaFault OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Fault :This OID indicates
the Line Trscv is in Fault state
<Help> Status indicating the Line
Trscv is in Fault state <Condtype>
MSA_FAULT <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmmsaModuleState 7 }
pm200frs02AlmMsaReady OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Ready :This OID indicates
the Line Trscv is ready to operate
<Help> Status indicating the Line
Trscv is ready to operate <Condtype>
MSA_READY <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmmsaModuleState 6 }
pm200frs02AlmMsaTxTurnOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Laser Turn On :This
OID indicates the Line Trscv is
turning on its laser <Help> Status
indicating the Line Trscv is turning
on its laser <Condtype> MSA_TX_TURN_ON
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmmsaModuleState 5 }
pm200frs02AlmMsaTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Laser Shutdown :This
OID indicates the Line Trscv Laser
is OFF <Help> Status indicating
the Line Trscv Laser is OFF <Condtype>
MSA_TX_OFF <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmmsaModuleState 4 }
pm200frs02AlmMsaHighPowerUp OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv High Power Up :This
OID indicates the Line Trscv is
leaving Low Power state <Help>
Status indicating the Line Trscv
is leaving Low Power state <Condtype>
MSA_HIGH_POWER_UP <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmmsaModuleState 3 }
pm200frs02AlmMsaLowPower OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Low Power :This OID
indicates the Line Trscv is in
low power state <Help> Status
indicating the Line Trscv is in
low power state <Condtype> MSA_LOW_POWER
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmmsaModuleState 2 }
pm200frs02AlmMsaInitialize OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Initialize :This OID
indicates the Line Trscv initialization
is in progress <Help> Status indicating
the Line Trscv initialization is
in progress <Condtype> MSA_INITIALIZE
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmmsaModuleState 1 }
--- *********************************************************
--- TABLE for the pm200frs02AlmclientHostLaneFault articles
--- *********************************************************
pm200frs02AlmclientHostLaneFaultTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02AlmclientHostLaneFaultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02AlmclientHostLaneFault
Article
"
::= { pm200frs02AlmClientUrg 152 }
pm200frs02AlmclientHostLaneFaultEntry OBJECT-TYPE
SYNTAX Pm200frs02AlmclientHostLaneFaultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02AlmclientHostLaneFault
table
"
INDEX { pm200frs02AlmclientHostLaneFaultIndex }
::= { pm200frs02AlmclientHostLaneFaultTable 1 }
Pm200frs02AlmclientHostLaneFaultEntry ::=
SEQUENCE {
pm200frs02AlmclientHostLaneFaultIndex
INTEGER,
pm200frs02AlmClientLaneTxFifoErrorPortn
EkiOnOff,
pm200frs02AlmClientTxHostLolPortn
EkiOnOff,
pm200frs02AlmClientCsfDetectedPortn
EkiOnOff,
pm200frs02AlmClientLanesNotAlignedPortn
EkiOnOff,
pm200frs02AlmClientLanes6466UnlockPortn
EkiOnOff,
pm200frs02AlmClientLanesMarkerUnlockPortn
EkiOnOff,
pm200frs02AlmClientInputLossOfSigPortn
EkiOnOff,
pm200frs02AlmClientLossOfSyncPortn
EkiOnOff
}
pm200frs02AlmclientHostLaneFaultIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02AlmclientHostLaneFault
table
"
::= { pm200frs02AlmclientHostLaneFaultEntry 1 }
pm200frs02AlmClientLaneTxFifoErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Host Lane Tx FIFO Error
:This OID indicates a Tx FIFO Error
on the Client Trscv Host Lane <Help>
Alarm indicating a Tx FIFO Error
on the Client Trscv Host Lane <Condtype>
CLIENT_LANE_TX_FIFO_ERROR <Probcause>
receiverFailure (42) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmclientHostLaneFaultEntry 11 }
pm200frs02AlmClientTxHostLolPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Host Lane Tx Loss Of Lock
:This OID indicates a Tx Loss of
Lock on the Client Trscv Host Lane
<Help> Alarm indicating a Tx Loss
of Lock on the Client Trscv Host
Lane <Condtype> CLIENT_TX_HOST_LOL
<Probcause> receiverFailure (42)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmclientHostLaneFaultEntry 10 }
pm200frs02AlmClientCsfDetectedPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Signal Fail Detected :This
OID indicates that a CSF has been
detected on client port in the
downstream direction <Help>
This alarm indicates if a Client
Signal Fail has been detected in
the incoming line frame for this
client port <Condtype> CLIENT_CSF_DETECTED
<Probcause> receiveFailure (41)
<Alarmtype> other(1) <Polarity>
(2)
"
::= { pm200frs02AlmclientHostLaneFaultEntry 7 }
pm200frs02AlmClientLanesNotAlignedPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Lanes Not Aligned :This
OID indicates the Client lanes
are not aligned <Help> Alarm indicating
the Client lanes are not aligned
<Condtype> CLIENT_LANES_NOT_ALIGNED
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation
(7) <Polarity> (2)
"
::= { pm200frs02AlmclientHostLaneFaultEntry 6 }
pm200frs02AlmClientLanes6466UnlockPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Lanes 64/66b Unlock :This
OID indicates the Client 64/66b
decoder is not lock <Help> Alarm
indicating the Client 64/66b decoder
is not lock <Condtype> CLIENT_LANES_64_66_UNLOCK
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation
(7) <Polarity> (2)
"
::= { pm200frs02AlmclientHostLaneFaultEntry 5 }
pm200frs02AlmClientLanesMarkerUnlockPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Lanes Marker Unlock :This
OID indicates the Client lanes
marker alignment is not lock <Help>
Alarm indicating the Client lanes
marker alignment is not lock <Condtype>
CLIENT_LANES_MARKER_UNLOCK <Probcause>
receiveFailure (41) <Alarmtype>
integrityViolation (7) <Polarity>
(2)
"
::= { pm200frs02AlmclientHostLaneFaultEntry 4 }
pm200frs02AlmClientInputLossOfSigPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Loss Of Signal :This
OID indicates a Loss of Signal
is detected on the Client Trscv
<Help> Alarm indicating a Loss
of Signal is detected on the Client
Trscv <Condtype> CLIENT_INPUT_LOSS_OF_SIG
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pm200frs02AlmclientHostLaneFaultEntry 3 }
pm200frs02AlmClientLossOfSyncPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Frame Alignment Loss :This
OID indicates the module is not
aligned with the incoming Client
signal <Help> Alarm indicating
the module is not aligned with
the incoming client signal <Condtype>
CLIENT_LOSS_OF_SYNC <Probcause>
receiveFailure (41) <Alarmtype>
integrityViolation (7) <Polarity>
(2)
"
::= { pm200frs02AlmclientHostLaneFaultEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02AlmlineNetworkLaneAlarmWarning1 articles
--- *********************************************************
pm200frs02AlmlineNetworkLaneAlarmWarning1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02AlmlineNetworkLaneAlarmWarning1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02AlmlineNetworkLaneAlarmWarning1
Article
"
::= { pm200frs02AlmLineNurg 184 }
pm200frs02AlmlineNetworkLaneAlarmWarning1Entry OBJECT-TYPE
SYNTAX Pm200frs02AlmlineNetworkLaneAlarmWarning1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02AlmlineNetworkLaneAlarmWarning1
table
"
INDEX { pm200frs02AlmlineNetworkLaneAlarmWarning1Index }
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Table 1 }
Pm200frs02AlmlineNetworkLaneAlarmWarning1Entry ::=
SEQUENCE {
pm200frs02AlmlineNetworkLaneAlarmWarning1Index
INTEGER,
pm200frs02AlmLineBiasHighAlarmPortn
EkiOnOff,
pm200frs02AlmLineBiasHighWarningPortn
EkiOnOff,
pm200frs02AlmLineBiasLowWarningPortn
EkiOnOff,
pm200frs02AlmLineBiasLowAlarmPortn
EkiOnOff,
pm200frs02AlmLineTxPowerHighAlarmPortn
EkiOnOff,
pm200frs02AlmLineTxPowerHighWarningPortn
EkiOnOff,
pm200frs02AlmLineTxPowerLowWarningPortn
EkiOnOff,
pm200frs02AlmLineTxPowerLowAlarmPortn
EkiOnOff,
pm200frs02AlmLineLaserTempHighAlarmPortn
EkiOnOff,
pm200frs02AlmLineLaserTempHighWarningPortn
EkiOnOff,
pm200frs02AlmLineLaserTempLowWarningPortn
EkiOnOff,
pm200frs02AlmLineLaserTempLowAlarmPortn
EkiOnOff,
pm200frs02AlmLineRxPowerHighAlarmPortn
EkiOnOff,
pm200frs02AlmLineRxPowerHighWarningPortn
EkiOnOff,
pm200frs02AlmLineRxPowerLowWarningPortn
EkiOnOff,
pm200frs02AlmLineRxPowerLowAlarmPortn
EkiOnOff
}
pm200frs02AlmlineNetworkLaneAlarmWarning1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02AlmlineNetworkLaneAlarmWarning1
table
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 1 }
pm200frs02AlmLineBiasHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Bias High Alarm
:This OID indicates that the Trscv
laser bias current is higher than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating that the Trscv laser
bias current is higher than the
threshold value written in the
Trscv EEPROM <Condtype> LINE_BIAS_HIGH_ALARM
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 17 }
pm200frs02AlmLineBiasHighWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Bias High Warning
:This OID indicates that the Trscv
laser bias current is higher than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating that the Trscv laser
bias current is higher than the
threshold value written in the
Trscv EEPROM <Condtype> LINE_BIAS_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 16 }
pm200frs02AlmLineBiasLowWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Bias Low Warning
:This OID indicates that the Trscv
laser bias current is lower than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating that the Trscv laser
bias current is lower than the
threshold value written in the
Trscv EEPROM <Condtype> LINE_BIAS_LOW_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 15 }
pm200frs02AlmLineBiasLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Bias Low Alarm :This
OID indicates that the Trscv laser
bias current is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that the Trscv laser bias current
is lower than the threshold value
written in the Trscv EEPROM <Condtype>
LINE_BIAS_LOW_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 14 }
pm200frs02AlmLineTxPowerHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Power High Alarm
:This OID indicates that the Trscv
output power is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that the Trscv output power is
higher than the threshold value
written in the Trscv EEPROM <Condtype>
LINE_TX_POWER_HIGH_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 13 }
pm200frs02AlmLineTxPowerHighWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Power High Warning
:This OID indicates that the Trscv
output power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that the Trscv output power is
higher than the threshold value
written in the Trscv EEPROM <Condtype>
LINE_TX_POWER_HIGH_WARNING <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 12 }
pm200frs02AlmLineTxPowerLowWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Power Low Warning
:This OID indicates that the Trscv
output power is lower than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that the Trscv output power is
lower than the threshold value
written in the Trscv EEPROM <Condtype>
LINE_TX_POWER_LOW_WARNING <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 11 }
pm200frs02AlmLineTxPowerLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Power Low Alarm
:This OID indicates that the Trscv
output power is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that the Trscv output power is
lower than the threshold value
written in the Trscv EEPROM <Condtype>
LINE_TX_POWER_LOW_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 10 }
pm200frs02AlmLineLaserTempHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Laser Temp High
Alarm :This OID indicates that
the Trscv Tx Laser Temperature
is higher than the threshold value
written in the Trscv EEPROM <Help>
Alarm indicating that the Trscv
Tx Laser Temperature is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
LINE_LASER_TEMP_HIGH_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 9 }
pm200frs02AlmLineLaserTempHighWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Laser Temp High
Warning :This OID indicates that
the Trscv Tx Laser Temperature
is higher than the threshold value
written in the Trscv EEPROM <Help>
Warning indicating that the Trscv
Tx Laser Temperature is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
LINE_LASER_TEMP_HIGH_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 8 }
pm200frs02AlmLineLaserTempLowWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Laser Temp Low Warning
:This OID indicates that the Trscv
Tx Laser Temperature is lower than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating that the Trscv Tx Laser
Temperature is lower than the threshold
value written in the Trscv EEPROM
<Condtype> LINE_LASER_TEMP_LOW_WARNING
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 7 }
pm200frs02AlmLineLaserTempLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Laser Temp Low Alarm
:This OID indicates that the Trscv
Tx Laser Temperature is lower than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating that the Trscv Tx Laser
Temperature is lower than the threshold
value written in the Trscv EEPROM
<Condtype> LINE_LASER_TEMP_LOW_ALARM
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 6 }
pm200frs02AlmLineRxPowerHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Power High Alarm
:This OID indicates that the Trscv
input power is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that the Trscv input power is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
LINE_RX_POWER_HIGH_ALARM <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 5 }
pm200frs02AlmLineRxPowerHighWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Power High Warning
:This OID indicates that the Trscv
input power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that the Trscv input power is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
LINE_RX_POWER_HIGH_WARNING <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 4 }
pm200frs02AlmLineRxPowerLowWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Power Low Warning
:This OID indicates that the Trscv
input power is lower than the threshold
value written in the Trscv EEPROM
<Help> Warning indicating that
the Trscv input power is lower
than the threshold value written
in the Trscv EEPROM <Condtype>
LINE_RX_POWER_LOW_WARNING <Probcause>
receiveFailure (41) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 3 }
pm200frs02AlmLineRxPowerLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Power Low Alarm
:This OID indicates that the Trscv
input power is lower than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
Trscv input power is lower than
the threshold value written in
the Trscv EEPROM <Condtype> LINE_RX_POWER_LOW_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning1Entry 2 }
--- *********************************************************
--- TABLE for the pm200frs02AlmlineNetworkLaneAlarmWarning2 articles
--- *********************************************************
pm200frs02AlmlineNetworkLaneAlarmWarning2Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02AlmlineNetworkLaneAlarmWarning2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02AlmlineNetworkLaneAlarmWarning2
Article
"
::= { pm200frs02AlmLineNurg 188 }
pm200frs02AlmlineNetworkLaneAlarmWarning2Entry OBJECT-TYPE
SYNTAX Pm200frs02AlmlineNetworkLaneAlarmWarning2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02AlmlineNetworkLaneAlarmWarning2
table
"
INDEX { pm200frs02AlmlineNetworkLaneAlarmWarning2Index }
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Table 1 }
Pm200frs02AlmlineNetworkLaneAlarmWarning2Entry ::=
SEQUENCE {
pm200frs02AlmlineNetworkLaneAlarmWarning2Index
INTEGER,
pm200frs02AlmRxLaserBiasHighAlarmPortn
EkiOnOff,
pm200frs02AlmRxLaserBiasHighWarningPortn
EkiOnOff,
pm200frs02AlmRxLaserBiasLowWarningPortn
EkiOnOff,
pm200frs02AlmRxLaserBiasLowAlarmPortn
EkiOnOff,
pm200frs02AlmRxLaserOutputHighAlarmPortn
EkiOnOff,
pm200frs02AlmRxLaserOutputHighWarningPortn
EkiOnOff,
pm200frs02AlmRxLaserOutputLowWarningPortn
EkiOnOff,
pm200frs02AlmRxLaserOutputLowAlarmPortn
EkiOnOff,
pm200frs02AlmRxLaserTempHighAlarmPortn
EkiOnOff,
pm200frs02AlmRxLaserTempHighWarningPortn
EkiOnOff,
pm200frs02AlmRxLaserTempLowWarningPortn
EkiOnOff,
pm200frs02AlmRxLaserTempLowAlarmPortn
EkiOnOff,
pm200frs02AlmTxModulatorBiasHighAlarmPortn
EkiOnOff,
pm200frs02AlmTxModulatorBiasHighWarningPortn
EkiOnOff,
pm200frs02AlmTxModulatorBiasLowWarningPortn
EkiOnOff,
pm200frs02AlmTxModulatorBiasLowAlarmPortn
EkiOnOff
}
pm200frs02AlmlineNetworkLaneAlarmWarning2Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02AlmlineNetworkLaneAlarmWarning2
table
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 1 }
pm200frs02AlmRxLaserBiasHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Bias High Alarm
:This OID indicates that the Trscv
Rx laser bias current is higher
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating that the Trscv Rx laser
bias current is higher than the
threshold value written in the
Trscv EEPROM <Condtype> RX_LASER_BIAS_HIGH_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 17 }
pm200frs02AlmRxLaserBiasHighWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Bias High Warning
:This OID indicates that the Trscv
Rx laser bias current is higher
than the threshold value written
in the Trscv EEPROM <Help> Warning
indicating that the Trscv Rx laser
bias current is higher than the
threshold value written in the
Trscv EEPROM <Condtype> RX_LASER_BIAS_HIGH_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 16 }
pm200frs02AlmRxLaserBiasLowWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Bias Low Warning
:This OID indicates that the Trscv
Rx laser bias current is lower
than the threshold value written
in the Trscv EEPROM <Help> Warning
indicating that the Trscv Rx laser
bias current is lower than the
threshold value written in the
Trscv EEPROM <Condtype> RX_LASER_BIAS_LOW_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 15 }
pm200frs02AlmRxLaserBiasLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Bias Low Alarm :This
OID indicates that the Trscv Rx
laser bias current is lower than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating that the Trscv Rx laser
bias current is lower than the
threshold value written in the
Trscv EEPROM <Condtype> RX_LASER_BIAS_LOW_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 14 }
pm200frs02AlmRxLaserOutputHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Output Power High
Alarm :This OID indicates that
the Trscv Rx output power is higher
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating that the Trscv Rx output
power is higher than the threshold
value written in the Trscv EEPROM
<Condtype> RX_LASER_OUTPUT_HIGH_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 13 }
pm200frs02AlmRxLaserOutputHighWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Output Power High
Warning :This OID indicates that
the Trscv Rx output power is higher
than the threshold value written
in the Trscv EEPROM <Help> Warning
indicating that the Trscv Rx output
power is higher than the threshold
value written in the Trscv EEPROM
<Condtype> RX_LASER_OUTPUT_HIGH_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 12 }
pm200frs02AlmRxLaserOutputLowWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Output Power Low
Warning :This OID indicates that
the Trscv Rx output power is lower
than the threshold value written
in the Trscv EEPROM <Help> Warning
indicating that the Trscv Rx output
power is lower than the threshold
value written in the Trscv EEPROM
<Condtype> RX_LASER_OUTPUT_LOW_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 11 }
pm200frs02AlmRxLaserOutputLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Output Power Low
Alarm :This OID indicates that
the Trscv Rx output power is lower
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating that the Trscv Rx output
power is lower than the threshold
value written in the Trscv EEPROM
<Condtype> RX_LASER_OUTPUT_LOW_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 10 }
pm200frs02AlmRxLaserTempHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Laser Temp High
Alarm :This OID indicates that
the Trscv Rx Laser Temperature
is higher than the threshold value
written in the Trscv EEPROM <Help>
Alarm indicating that the Trscv
Rx Laser Temperature is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
RX_LASER_TEMP_HIGH_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 9 }
pm200frs02AlmRxLaserTempHighWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Laser Temp High
Warning :This OID indicates that
the Trscv Rx Laser Temperature
is higher than the threshold value
written in the Trscv EEPROM <Help>
Warning indicating that the Trscv
Rx Laser Temperature is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
RX_LASER_TEMP_HIGH_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 8 }
pm200frs02AlmRxLaserTempLowWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Laser Temp Low Warning
:This OID indicates that the Trscv
Rx Laser Temperature is lower than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating that the Trscv Rx Laser
Temperature is lower than the threshold
value written in the Trscv EEPROM
<Condtype> RX_LASER_TEMP_LOW_WARNING
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 7 }
pm200frs02AlmRxLaserTempLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Rx Laser Temp Low Alarm
:This OID indicates that the Trscv
Rx Laser Temperature is lower than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating that the Trscv Rx Laser
Temperature is lower than the threshold
value written in the Trscv EEPROM
<Condtype> RX_LASER_TEMP_LOW_ALARM
<Probcause> temperatureUnacceptable
(51) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 6 }
pm200frs02AlmTxModulatorBiasHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Modulator Bias High
Alarm :This OID indicates that
the Trscv Tx modulator bias current
is higher than the threshold value
written in the Trscv EEPROM <Help>
Alarm indicating that the Trscv
Tx modulator bias current is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
TX_MODULATOR_BIAS_HIGH_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 5 }
pm200frs02AlmTxModulatorBiasHighWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Modulator Bias High
Warning :This OID indicates that
the Trscv Tx modulator bias current
is higher than the threshold value
written in the Trscv EEPROM <Help>
Warning indicating that the Trscv
Tx modulator bias current is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
TX_MODULATOR_BIAS_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 4 }
pm200frs02AlmTxModulatorBiasLowWarningPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Modulator Bias Low
Warning :This OID indicates that
the Trscv Tx modulator bias current
is lower than the threshold value
written in the Trscv EEPROM <Help>
Warning indicating that the Trscv
Tx modulator bias current is lower
than the threshold value written
in the Trscv EEPROM <Condtype>
TX_MODULATOR_BIAS_LOW_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 3 }
pm200frs02AlmTxModulatorBiasLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Tx Modulator Bias Low
Alarm :This OID indicates that
the Trscv Tx modulator bias current
is lower than the threshold value
written in the Trscv EEPROM <Help>
Alarm indicating that the Trscv
Tx modulator bias current is lower
than the threshold value written
in the Trscv EEPROM <Condtype>
TX_MODULATOR_BIAS_LOW_ALARM <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineNetworkLaneAlarmWarning2Entry 2 }
--- *********************************************************
--- TABLE for the pm200frs02AlmlineHostLaneFault articles
--- *********************************************************
pm200frs02AlmlineHostLaneFaultTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02AlmlineHostLaneFaultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02AlmlineHostLaneFault
Article
"
::= { pm200frs02AlmLineUrg 196 }
pm200frs02AlmlineHostLaneFaultEntry OBJECT-TYPE
SYNTAX Pm200frs02AlmlineHostLaneFaultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02AlmlineHostLaneFault
table
"
INDEX { pm200frs02AlmlineHostLaneFaultIndex }
::= { pm200frs02AlmlineHostLaneFaultTable 1 }
Pm200frs02AlmlineHostLaneFaultEntry ::=
SEQUENCE {
pm200frs02AlmlineHostLaneFaultIndex
INTEGER,
pm200frs02AlmLineLaneTxFifoErrorPortn
EkiOnOff,
pm200frs02AlmLineTxHostLolPortn
EkiOnOff,
pm200frs02AlmLineSmIaeDetectedPortn
EkiOnOff,
pm200frs02AlmLineSmIaeInsertedPortn
EkiOnOff,
pm200frs02AlmLineSmBdiDetectedPortn
EkiOnOff,
pm200frs02AlmLineSmBdiInsertedPortn
EkiOnOff,
pm200frs02AlmLineLossOfFramePortn
EkiOnOff,
pm200frs02AlmLineInputLossOfSignalPortn
EkiOnOff
}
pm200frs02AlmlineHostLaneFaultIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02AlmlineHostLaneFault
table
"
::= { pm200frs02AlmlineHostLaneFaultEntry 1 }
pm200frs02AlmLineLaneTxFifoErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Host Lane Tx FIFO Error :This
OID indicates a Tx FIFO Error on
the Line Trscv Host Lane <Help>
Alarm indicating a Tx FIFO Error
on the Line Trscv Host Lane <Condtype>
LINE_LANE_TX_FIFO_ERROR <Probcause>
receiverFailure (42) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pm200frs02AlmlineHostLaneFaultEntry 11 }
pm200frs02AlmLineTxHostLolPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Host Lane Tx Loss Of Lock
:This OID indicates a Tx Loss of
Lock on the Line Trscv Host Lane
<Help> Alarm indicating a Tx Loss
of Lock on the Line Trscv Host
Lane <Condtype> LINE_TX_HOST_LOL
<Probcause> receiverFailure (42)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pm200frs02AlmlineHostLaneFaultEntry 10 }
pm200frs02AlmLineSmIaeDetectedPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line SM IAE Detected :This OID
indicates a SM Incoming Alignment
Error is detected on the incoming
Line signal <Help> Alarm indicating
a SM Incoming Alignment Error is
detected on the incoming Line signal
<Condtype> LINE_SM_IAE_DETECTED
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation
(7) <Polarity> (2)
"
::= { pm200frs02AlmlineHostLaneFaultEntry 7 }
pm200frs02AlmLineSmIaeInsertedPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line SM IAE Inserted :This OID
indicates a SM Incoming Alignment
Error is inserted on the outgoing
Line signal <Help> Status indicating
a SM Incoming Alignment Error is
inserted on the outgoing Line signal
<Condtype> LINE_SM_IAE_INSERTED
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmlineHostLaneFaultEntry 6 }
pm200frs02AlmLineSmBdiDetectedPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line SM BDI Detected :This OID
indicates a SM Backward Defect
Indication is detected on the
incoming Line signal <Help> Alarm
indicating a SM Backward Defect
Indication is detected on the incoming
Line signal <Condtype> LINE_SM_BDI_DETECTED
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation
(7) <Polarity> (2)
"
::= { pm200frs02AlmlineHostLaneFaultEntry 5 }
pm200frs02AlmLineSmBdiInsertedPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line SM BDI Inserted :This OID
indicates a SM Backward Defect
Indication is inserted on the
outgoing Line signal <Help> Status
indicating a SM Backward Defect
Indication is inserted on the outgoing
Line signal <Condtype> LINE_SM_BDI_INSERTED
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pm200frs02AlmlineHostLaneFaultEntry 4 }
pm200frs02AlmLineLossOfFramePortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Loss Of Frame :This OID indicates
the module is not aligned with
the incoming Line signal <Help>
Alarm indicating the module is
not aligned with the incoming
Line signal <Condtype> LINE_LOSS_OF_FRAME
<Probcause> receiveFailure (41)
<Alarmtype> integrityViolation
(7) <Polarity> (2)
"
::= { pm200frs02AlmlineHostLaneFaultEntry 3 }
pm200frs02AlmLineInputLossOfSignalPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Input Loss Of Signal :This
OID indicates a Loss of Signal
is detected on the Line Trscv
<Help> Alarm indicating a Loss
of Signal is detected on the Line
Trscv <Condtype> LINE_INPUT_LOSS_OF_SIGNAL
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pm200frs02AlmlineHostLaneFaultEntry 2 }
--- *****************************************************
--- LEAF for the clientQsfpAlarmDdm article
--- *****************************************************
pm200frs02AlmclientQsfpAlarmDdm OBJECT IDENTIFIER ::= { pm200frs02AlmOtherUrg 337 }
pm200frs02AlmTrscv2TempHighAla1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Temp High Alarm :This
OID indicates that the Trscv temperature
of port is higher than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
Trscv temperature of port is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
TRSCV2_TEMP_HIGH_ALA_1 <Probcause>
temperatureUnacceptable (51) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpAlarmDdm 8 }
pm200frs02AlmTrscv2TempLowAla1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Temp Low Alarm :This
OID indicates that the Trscv temperature
of port is lower than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
Trscv temperature of port is lower
than the threshold value written
in the Trscv EEPROM <Condtype>
TRSCV2_TEMP_LOW_ALA_1 <Probcause>
temperatureUnacceptable (51) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpAlarmDdm 7 }
pm200frs02AlmTrscv2VccHighAla1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Power Supply High Alarm
:This OID indicates that the Trscv
power supply of port is higher
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating that the Trscv power
supply of port is higher than the
threshold value written in the
Trscv EEPROM <Condtype> TRSCV2_VCC_HIGH_ALA_1
<Probcause> powerProblem (36) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpAlarmDdm 6 }
pm200frs02AlmTrscv2VccLowAla1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Power Supply Low Alarm
:This OID indicates that the Trscv
power supply of port is lower than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating that the Trscv power
supply of port is lower than the
threshold value written in the
Trscv EEPROM <Condtype> TRSCV2_VCC_LOW_ALA_1
<Probcause> powerProblem (36) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpAlarmDdm 5 }
pm200frs02AlmTrscv1TempHighAla OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Temp High Alarm :This
OID indicates that the Trscv temperature
of port is higher than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
Trscv temperature of port is higher
than the threshold value written
in the Trscv EEPROM <Condtype>
TRSCV1_TEMP_HIGH_ALA <Probcause>
temperatureUnacceptable (51) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpAlarmDdm 4 }
pm200frs02AlmTrscv1TempLowAla1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Temp Low Alarm :This
OID indicates that the Trscv temperature
of port is lower than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
Trscv temperature of port is lower
than the threshold value written
in the Trscv EEPROM <Condtype>
TRSCV1_TEMP_LOW_ALA_1 <Probcause>
temperatureUnacceptable (51) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpAlarmDdm 3 }
pm200frs02AlmTrscv1VccHighAla1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Power Supply High Alarm
:This OID indicates that the Trscv
power supply of port is higher
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating that the Trscv power
supply of port is higher than the
threshold value written in the
Trscv EEPROM <Condtype> TRSCV1_VCC_HIGH_ALA_1
<Probcause> powerProblem (36) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpAlarmDdm 2 }
pm200frs02AlmTrscv1VccLowAla1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Power Supply Low Alarm
:This OID indicates that the Trscv
power supply of port is lower than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating that the Trscv power
supply of port is lower than the
threshold value written in the
Trscv EEPROM <Condtype> TRSCV1_VCC_LOW_ALA_1
<Probcause> powerProblem (36) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpAlarmDdm 1 }
--- *****************************************************
--- LEAF for the clientQsfpWarnDdm article
--- *****************************************************
pm200frs02AlmclientQsfpWarnDdm OBJECT IDENTIFIER ::= { pm200frs02AlmOtherNurg 338 }
pm200frs02AlmTrscv2TempHighWng1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Temp High Warning :This
OID indicates that the Trscv temperature
is higher than the threshold value
written in the Trscv EEPROM <Help>
Warning indicating that the Trscv
temperature is higher than the
threshold value written in the
Trscv EEPROM <Condtype> TRSCV2_TEMP_HIGH_WNG_1
<Probcause> temperatureUnacceptable
(51) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpWarnDdm 8 }
pm200frs02AlmTrscv2TempLowWng1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Temp Low Warning :This
OID indicates that the Trscv temperature
is lower than the threshold value
written in the Trscv EEPROM <Help>
Warning indicating that the Trscv
temperature is lower than the threshold
value written in the Trscv EEPROM
<Condtype> TRSCV2_TEMP_LOW_WNG_1
<Probcause> temperatureUnacceptable
(51) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpWarnDdm 7 }
pm200frs02AlmTrscv2VccHighWng1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Power Supply High Warning
:This OID indicates that the Trscv
power supply is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that the Trscv power supply is
higher than the threshold value
written in the Trscv EEPROM <Condtype>
TRSCV2_VCC_HIGH_WNG_1 <Probcause>
powerProblem (36) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpWarnDdm 6 }
pm200frs02AlmTrscv2VccLowWng1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Power Supply Low Warning
:This OID indicates that the Trscv
power supply is lower than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that the Trscv power supply is
lower than the threshold value
written in the Trscv EEPROM <Condtype>
TRSCV2_VCC_LOW_WNG_1 <Probcause>
powerProblem (36) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpWarnDdm 5 }
pm200frs02AlmTrscv1TempHighWng1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Temp High Warning :This
OID indicates that the Trscv temperature
is higher than the threshold value
written in the Trscv EEPROM <Help>
Warning indicating that the Trscv
temperature is higher than the
threshold value written in the
Trscv EEPROM <Condtype> TRSCV1_TEMP_HIGH_WNG_1
<Probcause> temperatureUnacceptable
(51) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpWarnDdm 4 }
pm200frs02AlmTrscv1TempLowWng1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Temp Low Warning :This
OID indicates that the Trscv temperature
is lower than the threshold value
written in the Trscv EEPROM <Help>
Warning indicating that the Trscv
temperature is lower than the threshold
value written in the Trscv EEPROM
<Condtype> TRSCV1_TEMP_LOW_WNG_1
<Probcause> temperatureUnacceptable
(51) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpWarnDdm 3 }
pm200frs02AlmTrscv1VccHighWng1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Power Supply High Warning
:This OID indicates that the Trscv
power supply is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that the Trscv power supply is
higher than the threshold value
written in the Trscv EEPROM <Condtype>
TRSCV1_VCC_HIGH_WNG_1 <Probcause>
powerProblem (36) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpWarnDdm 2 }
pm200frs02AlmTrscv1VccLowWng1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Power Supply Low Warning
:This OID indicates that the Trscv
power supply is lower than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that the Trscv power supply is
lower than the threshold value
written in the Trscv EEPROM <Condtype>
TRSCV1_VCC_LOW_WNG_1 <Probcause>
powerProblem (36) <Alarmtype>
"
::= { pm200frs02AlmclientQsfpWarnDdm 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the confMgnt1 article
--- *****************************************************
pm200frs02CtrlconfMgnt1 OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 1 }
pm200frs02CtrlConf2Clear1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
OID clears the configuration tables
from configuration2 in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pm200frs02CtrlconfMgnt1 14 }
pm200frs02CtrlConf2Flash1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
OID saves the current configuration
of the PM as configuration2 in
the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pm200frs02CtrlconfMgnt1 10 }
pm200frs02CtrlConf2Load1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables Set
Nb 2 :When set this OID enables
loading from flash configuration2
into the PM.
"
::= { pm200frs02CtrlconfMgnt1 2 }
pm200frs02CtrlConf1Load1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables Set
Nb 1 :When set this OID enables
loading from flash configuration1
into the PM.
"
::= { pm200frs02CtrlconfMgnt1 1 }
--- *****************************************************
--- LEAF for the synth4 article
--- *****************************************************
pm200frs02Ctrlsynth4 OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 4 }
pm200frs02CtrlCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Disable Alarm Correlation :This
OID disables the alarm correlation
in the PM.
"
::= { pm200frs02Ctrlsynth4 2 }
pm200frs02CtrlCorrelatOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Enable Alarm Correlation :This
OID enables the alarm correlation
in the PM.
"
::= { pm200frs02Ctrlsynth4 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pm200frs02CtrlswMgnt OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 5 }
pm200frs02CtrlLoadSwBank2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Software Nb 2 As Active :This
OID, when set, loads the SW from
bank2 into the PM. It must be followed
by a reset. <Help> This controls
selects the second SW bank as the
active bank for the next module
reset
"
::= { pm200frs02CtrlswMgnt 6 }
pm200frs02CtrlLoadSwBank1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Software Nb 1 As Active :This
OID, when set, loads the SW from
bank1 into the PM. It must be followed
by a reset. <Help> This controls
selects the first SW bank as the
active bank for the next module
reset
"
::= { pm200frs02CtrlswMgnt 5 }
pm200frs02CtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Warm Reset :This OID, when
set, causes a warm reset of the
PM. This reset is not traffic affecting,
and the configuration of PM remains
unchanged. <Help> This control
initiates a warm reset of the module.
"
::= { pm200frs02CtrlswMgnt 3 }
pm200frs02CtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Cold Reset :This OID, when
set, causes a cold reset of the
PM. This reset is traffic affecting,
and the configuration of PM is
reloaded on start-up. <Help>
This control initiates a cold
reset of the module.
"
::= { pm200frs02CtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the gwMgnt article
--- *****************************************************
pm200frs02CtrlgwMgnt OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 6 }
pm200frs02CtrlLoadGwBank4 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Gateware Nb 4 As Active :This
OID, when set, loads the GW from
bank4 (Flash) into the PM. It is
followed by an automatic gateware
cold reset.
"
::= { pm200frs02CtrlgwMgnt 8 }
pm200frs02CtrlLoadGwBank3 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Gateware Nb 3 As Active :This
OID, when set, loads the GW from
bank3 (Flash) into the PM. It is
followed by an automatic gateware
cold reset. <Help> This controls
initiates a cold reset of the module
and select the third GW bank as
the active bank
"
::= { pm200frs02CtrlgwMgnt 7 }
pm200frs02CtrlLoadGwBank2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Gateware Nb 2 As Active :This
OID, when set, loads the GW from
bank2 (Flash) into the PM. It is
followed by an automatic gateware
cold reset.
"
::= { pm200frs02CtrlgwMgnt 6 }
pm200frs02CtrlLoadGwBank1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Gateware Nb 1 As Active :This
OID, when set, loads the GW from
bank1 (Flash) into the PM. It is
followed by an automatic gateware
cold reset. <Help> This controls
initiates a cold reset of the module
and select the first GW bank as
the active bank
"
::= { pm200frs02CtrlgwMgnt 5 }
pm200frs02CtrlCurrentGwReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Active Gateware Reset :This OID,
when set, resets the active gateware.
It is traffic affecting.
"
::= { pm200frs02CtrlgwMgnt 1 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlaccessLoop articles
--- *********************************************************
pm200frs02CtrlaccessLoopTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlaccessLoopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlaccessLoop
Article
"
::= { pm200frs02CtrlClient 16 }
pm200frs02CtrlaccessLoopEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlaccessLoopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlaccessLoop
table
"
INDEX { pm200frs02CtrlaccessLoopIndex }
::= { pm200frs02CtrlaccessLoopTable 1 }
Pm200frs02CtrlaccessLoopEntry ::=
SEQUENCE {
pm200frs02CtrlaccessLoopIndex
INTEGER,
pm200frs02CtrlaccessLoopPortn
EkiState
}
pm200frs02CtrlaccessLoopIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlaccessLoop
table
"
::= { pm200frs02CtrlaccessLoopEntry 1 }
pm200frs02CtrlaccessLoopPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Client Facility Loopback :This
OID, when set at '1' puts the client
port in loopback, looping the received
10 Gb/s signal on the transmit
10 Gb/s output. <Help> This control
enables the Out Loopback on the
client port, looping the client
input signal on the client output
"
::= { pm200frs02CtrlaccessLoopEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlclientLoopToLine articles
--- *********************************************************
pm200frs02CtrlclientLoopToLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlclientLoopToLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlclientLoopToLine
Article
"
::= { pm200frs02CtrlClient 17 }
pm200frs02CtrlclientLoopToLineEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlclientLoopToLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlclientLoopToLine
table
"
INDEX { pm200frs02CtrlclientLoopToLineIndex }
::= { pm200frs02CtrlclientLoopToLineTable 1 }
Pm200frs02CtrlclientLoopToLineEntry ::=
SEQUENCE {
pm200frs02CtrlclientLoopToLineIndex
INTEGER,
pm200frs02CtrlclientLoopToLinePortn
EkiState
}
pm200frs02CtrlclientLoopToLineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlclientLoopToLine
table
"
::= { pm200frs02CtrlclientLoopToLineEntry 1 }
pm200frs02CtrlclientLoopToLinePortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Client Terminal Loopback :This
OID, when set, puts the client
port in loop back, looping the
10 Gb/s output signal on the 10
Gb/s input.<Help> This control
enables the In Loopback on the
client port, looping the client
output signal on the client input
"
::= { pm200frs02CtrlclientLoopToLineEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlcsfUpIns articles
--- *********************************************************
pm200frs02CtrlcsfUpInsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlcsfUpInsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlcsfUpIns
Article
"
::= { pm200frs02CtrlClient 21 }
pm200frs02CtrlcsfUpInsEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlcsfUpInsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlcsfUpIns
table
"
INDEX { pm200frs02CtrlcsfUpInsIndex }
::= { pm200frs02CtrlcsfUpInsTable 1 }
Pm200frs02CtrlcsfUpInsEntry ::=
SEQUENCE {
pm200frs02CtrlcsfUpInsIndex
INTEGER,
pm200frs02CtrlcsfUpInsPortn
EkiState
}
pm200frs02CtrlcsfUpInsIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlcsfUpIns
table
"
::= { pm200frs02CtrlcsfUpInsEntry 1 }
pm200frs02CtrlcsfUpInsPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Client Signal Fail Insertion :This
OID, when set, inserts a client
signal fail in the upstream client
Port. <Help> This control inserts
a Client Signal Fail for the client
port
"
::= { pm200frs02CtrlcsfUpInsEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlcaisDwIns articles
--- *********************************************************
pm200frs02CtrlcaisDwInsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlcaisDwInsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlcaisDwIns
Article
"
::= { pm200frs02CtrlClient 22 }
pm200frs02CtrlcaisDwInsEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlcaisDwInsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlcaisDwIns
table
"
INDEX { pm200frs02CtrlcaisDwInsIndex }
::= { pm200frs02CtrlcaisDwInsTable 1 }
Pm200frs02CtrlcaisDwInsEntry ::=
SEQUENCE {
pm200frs02CtrlcaisDwInsIndex
INTEGER,
pm200frs02CtrlcaisDwInsPortn
EkiState
}
pm200frs02CtrlcaisDwInsIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlcaisDwIns
table
"
::= { pm200frs02CtrlcaisDwInsEntry 1 }
pm200frs02CtrlcaisDwInsPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Client AIS Insertion :This OID,
when set, inserts a client AIS
on the downstream client Port.
<Help> This control inserts a
Client AIS for the client port
"
::= { pm200frs02CtrlcaisDwInsEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlcommAccessLoop articles
--- *********************************************************
pm200frs02CtrlcommAccessLoopTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlcommAccessLoopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlcommAccessLoop
Article
"
::= { pm200frs02CtrlLine 64 }
pm200frs02CtrlcommAccessLoopEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlcommAccessLoopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlcommAccessLoop
table
"
INDEX { pm200frs02CtrlcommAccessLoopIndex }
::= { pm200frs02CtrlcommAccessLoopTable 1 }
Pm200frs02CtrlcommAccessLoopEntry ::=
SEQUENCE {
pm200frs02CtrlcommAccessLoopIndex
INTEGER,
pm200frs02CtrlcommAccessLoopPortn
EkiState
}
pm200frs02CtrlcommAccessLoopIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlcommAccessLoop
table
"
::= { pm200frs02CtrlcommAccessLoopEntry 1 }
pm200frs02CtrlcommAccessLoopPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Line Terminal Loopback :This OID,
when set, puts the module in common
access loop back, looping the 200
Gb/s output signal on the 200 Gb/s
input.<Help> This control enables
the In Loopback on the line port,
looping the 200 Gb/s output signal
on the 200 Gb/s input
"
::= { pm200frs02CtrlcommAccessLoopEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrllineLoop articles
--- *********************************************************
pm200frs02CtrllineLoopTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrllineLoopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrllineLoop
Article
"
::= { pm200frs02CtrlLine 66 }
pm200frs02CtrllineLoopEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrllineLoopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrllineLoop
table
"
INDEX { pm200frs02CtrllineLoopIndex }
::= { pm200frs02CtrllineLoopTable 1 }
Pm200frs02CtrllineLoopEntry ::=
SEQUENCE {
pm200frs02CtrllineLoopIndex
INTEGER,
pm200frs02CtrllineLoopPortn
EkiState
}
pm200frs02CtrllineLoopIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrllineLoop
table
"
::= { pm200frs02CtrllineLoopEntry 1 }
pm200frs02CtrllineLoopPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Line Facility Loopback :This OID,
when set at '1' puts the module
in line loopback mode, looping
the received 200 Gb/s signal on
the transmit 200 Gb/s output. The
Upstream part of the module is
timed on the 200 Gb/s recovered
clock in that case.<Help> This
control enables the Out Loopback
on the line port, looping the 200
Gb/s input signal on the 200 Gb/s
output
"
::= { pm200frs02CtrllineLoopEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlfecDisable articles
--- *********************************************************
pm200frs02CtrlfecDisableTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlfecDisableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlfecDisable
Article
"
::= { pm200frs02CtrlLine 69 }
pm200frs02CtrlfecDisableEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlfecDisableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlfecDisable
table
"
INDEX { pm200frs02CtrlfecDisableIndex }
::= { pm200frs02CtrlfecDisableTable 1 }
Pm200frs02CtrlfecDisableEntry ::=
SEQUENCE {
pm200frs02CtrlfecDisableIndex
INTEGER,
pm200frs02CtrlfecDisablePortn
EkiState
}
pm200frs02CtrlfecDisableIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlfecDisable
table
"
::= { pm200frs02CtrlfecDisableEntry 1 }
pm200frs02CtrlfecDisablePortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Forward Error Correction Inhibition
:This OID, when set, inhibits the
Forward Error Correction feature
on the line input <Help> This
control enables/disables the Forward
Error Correction on the line interface
"
::= { pm200frs02CtrlfecDisableEntry 2 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pm200frs02CtrlledTest OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 192 }
pm200frs02CtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pm200frs02CtrlledTest 3 }
pm200frs02CtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pm200frs02CtrlledTest 2 }
pm200frs02CtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pm200frs02CtrlledTest 1 }
--- *****************************************************
--- LEAF for the initSwitchMarvell article
--- *****************************************************
pm200frs02CtrlinitSwitchMarvell OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 201 }
pm200frs02CtrlInitSwitchMarvell OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Switch Initialization :This OID
operates an initialization of the
switch managed through the module
<Help> This control activates
an initialization of the switch
managed through the module
"
::= { pm200frs02CtrlinitSwitchMarvell 1 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlmsaLineLoop articles
--- *********************************************************
pm200frs02CtrlmsaLineLoopTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlmsaLineLoopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlmsaLineLoop
Article
"
::= { pm200frs02CtrlLine 209 }
pm200frs02CtrlmsaLineLoopEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlmsaLineLoopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlmsaLineLoop
table
"
INDEX { pm200frs02CtrlmsaLineLoopIndex }
::= { pm200frs02CtrlmsaLineLoopTable 1 }
Pm200frs02CtrlmsaLineLoopEntry ::=
SEQUENCE {
pm200frs02CtrlmsaLineLoopIndex
INTEGER,
pm200frs02CtrlmsaLineLoopPortn
EkiState
}
pm200frs02CtrlmsaLineLoopIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlmsaLineLoop
table
"
::= { pm200frs02CtrlmsaLineLoopEntry 1 }
pm200frs02CtrlmsaLineLoopPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
MSA Line Loop :This OID operates
a line loopback on the MSA Line
<Help> This control defines the
line loop back of the line transceiver
"
::= { pm200frs02CtrlmsaLineLoopEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlmsaTxReset articles
--- *********************************************************
pm200frs02CtrlmsaTxResetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlmsaTxResetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlmsaTxReset
Article
"
::= { pm200frs02CtrlLine 210 }
pm200frs02CtrlmsaTxResetEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlmsaTxResetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlmsaTxReset
table
"
INDEX { pm200frs02CtrlmsaTxResetIndex }
::= { pm200frs02CtrlmsaTxResetTable 1 }
Pm200frs02CtrlmsaTxResetEntry ::=
SEQUENCE {
pm200frs02CtrlmsaTxResetIndex
INTEGER,
pm200frs02CtrlmsaTxResetPortn
EkiState
}
pm200frs02CtrlmsaTxResetIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlmsaTxReset
table
"
::= { pm200frs02CtrlmsaTxResetEntry 1 }
pm200frs02CtrlmsaTxResetPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Line MSA TX Reset :This OID resets
the TX portion of the MSA line
module <Help > This control
initiates a reset of the transmitting
side
"
::= { pm200frs02CtrlmsaTxResetEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlmsaRxReset articles
--- *********************************************************
pm200frs02CtrlmsaRxResetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlmsaRxResetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlmsaRxReset
Article
"
::= { pm200frs02CtrlLine 211 }
pm200frs02CtrlmsaRxResetEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlmsaRxResetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlmsaRxReset
table
"
INDEX { pm200frs02CtrlmsaRxResetIndex }
::= { pm200frs02CtrlmsaRxResetTable 1 }
Pm200frs02CtrlmsaRxResetEntry ::=
SEQUENCE {
pm200frs02CtrlmsaRxResetIndex
INTEGER,
pm200frs02CtrlmsaRxResetPortn
EkiState
}
pm200frs02CtrlmsaRxResetIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlmsaRxReset
table
"
::= { pm200frs02CtrlmsaRxResetEntry 1 }
pm200frs02CtrlmsaRxResetPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Line MSA RX Reset :This OID resets
the RX portion of the MSA line
module <Help > This control
initiates a reset of the receiving
side
"
::= { pm200frs02CtrlmsaRxResetEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlmsaShutdown articles
--- *********************************************************
pm200frs02CtrlmsaShutdownTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlmsaShutdownEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlmsaShutdown
Article
"
::= { pm200frs02CtrlLine 212 }
pm200frs02CtrlmsaShutdownEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlmsaShutdownEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlmsaShutdown
table
"
INDEX { pm200frs02CtrlmsaShutdownIndex }
::= { pm200frs02CtrlmsaShutdownTable 1 }
Pm200frs02CtrlmsaShutdownEntry ::=
SEQUENCE {
pm200frs02CtrlmsaShutdownIndex
INTEGER,
pm200frs02CtrlmsaShutdownPortn
EkiState
}
pm200frs02CtrlmsaShutdownIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlmsaShutdown
table
"
::= { pm200frs02CtrlmsaShutdownEntry 1 }
pm200frs02CtrlmsaShutdownPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Line MSA Shutdown :This OID enters
a process to shutdown the MSA line
module <Help > This control initiates
a shutdown of the module
"
::= { pm200frs02CtrlmsaShutdownEntry 2 }
--- *****************************************************
--- LEAF for the resetCount article
--- *****************************************************
pm200frs02CtrlresetCount OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 259 }
pm200frs02CtrlResetcount OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Module Count Global Reset :This
OID resets all the errors counters
on the module <Help > This control
initiates a reset of the errors
counters on the module
"
::= { pm200frs02CtrlresetCount 1 }
--- *****************************************************
--- LEAF for the resetRmon article
--- *****************************************************
pm200frs02CtrlresetRmon OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 260 }
pm200frs02CtrlResetrmon OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Module Rmon Global Reset :This
OID resets all the Rmon counters
on the module <Help > This control
initiates a reset of the Rmon
counters on the module
"
::= { pm200frs02CtrlresetRmon 1 }
--- *****************************************************
--- LEAF for the resetMeasurements article
--- *****************************************************
pm200frs02CtrlresetMeasurements OBJECT IDENTIFIER ::= { pm200frs02CtrlOther 261 }
pm200frs02CtrlResetmeasurements OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Management Meas Global Reset :This
OID resets some measurements on
the management <Help > This control
initiates a reset of some measurements
on the management
"
::= { pm200frs02CtrlresetMeasurements 1 }
--- *********************************************************
--- TABLE for the pm200frs02CtrlclientResetAllCount articles
--- *********************************************************
pm200frs02CtrlclientResetAllCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrlclientResetAllCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrlclientResetAllCount
Article
"
::= { pm200frs02CtrlClient 262 }
pm200frs02CtrlclientResetAllCountEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrlclientResetAllCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrlclientResetAllCount
table
"
INDEX { pm200frs02CtrlclientResetAllCountIndex }
::= { pm200frs02CtrlclientResetAllCountTable 1 }
Pm200frs02CtrlclientResetAllCountEntry ::=
SEQUENCE {
pm200frs02CtrlclientResetAllCountIndex
INTEGER,
pm200frs02CtrlclientResetAllCountsPortn
EkiState
}
pm200frs02CtrlclientResetAllCountIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrlclientResetAllCount
table
"
::= { pm200frs02CtrlclientResetAllCountEntry 1 }
pm200frs02CtrlclientResetAllCountsPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Client Counters Reset :This OID
resets every counter on the client
port <Help> This control operates
a reset on the statistics current
,previous and history client port
counters
"
::= { pm200frs02CtrlclientResetAllCountEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02CtrllineResetAllCount articles
--- *********************************************************
pm200frs02CtrllineResetAllCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CtrllineResetAllCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CtrllineResetAllCount
Article
"
::= { pm200frs02CtrlLine 263 }
pm200frs02CtrllineResetAllCountEntry OBJECT-TYPE
SYNTAX Pm200frs02CtrllineResetAllCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CtrllineResetAllCount
table
"
INDEX { pm200frs02CtrllineResetAllCountIndex }
::= { pm200frs02CtrllineResetAllCountTable 1 }
Pm200frs02CtrllineResetAllCountEntry ::=
SEQUENCE {
pm200frs02CtrllineResetAllCountIndex
INTEGER,
pm200frs02CtrllineResetAllCountsPortn
EkiState
}
pm200frs02CtrllineResetAllCountIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CtrllineResetAllCount
table
"
::= { pm200frs02CtrllineResetAllCountEntry 1 }
pm200frs02CtrllineResetAllCountsPortn OBJECT-TYPE
SYNTAX EkiState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Line Counters Reset :This OID
resets every counter on the line
port <Help> This control operates
a reset on the statistics current
,previous and history line port
counters
"
::= { pm200frs02CtrllineResetAllCountEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- COUNTERS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02CntclientInputErrorCounter articles
--- *********************************************************
pm200frs02CntclientInputErrorCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntclientInputErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntclientInputErrorCounter
Article
"
::= { pm200frs02CntClient 112 }
pm200frs02CntclientInputErrorCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntclientInputErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntclientInputErrorCounter
table
"
INDEX { pm200frs02CntclientInputErrorCounterIndex }
::= { pm200frs02CntclientInputErrorCounterTable 1 }
Pm200frs02CntclientInputErrorCounterEntry ::=
SEQUENCE {
pm200frs02CntclientInputErrorCounterIndex
INTEGER,
pm200frs02CntclientInputErrorCounterValuePortn
Counter32,
pm200frs02CntclientInputErrorCounterErrorPortn
EkiOnOff,
pm200frs02CntclientInputErrorCounterOverloadPortn
EkiOnOff
}
pm200frs02CntclientInputErrorCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntclientInputErrorCounter
table
"
::= { pm200frs02CntclientInputErrorCounterEntry 1 }
pm200frs02CntclientInputErrorCounterValuePortn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Errors :This counter
gives the number of SM-BIP8 on
the client port (OTU4 only) <Help>
This counter gives the number
of SM-BIP8 on the client port
(OTU4 only)
"
::= { pm200frs02CntclientInputErrorCounterEntry 2 }
pm200frs02CntclientInputErrorCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Counter Error :This OID
when set indicates the BIP8 error
counter value is invalid on Port
"
::= { pm200frs02CntclientInputErrorCounterEntry 3 }
pm200frs02CntclientInputErrorCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Counter Overload :This
OID when set indicates a BIP8
error counter overload on Port
"
::= { pm200frs02CntclientInputErrorCounterEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntclientCbipCounter articles
--- *********************************************************
pm200frs02CntclientCbipCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntclientCbipCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntclientCbipCounter
Article
"
::= { pm200frs02CntClient 144 }
pm200frs02CntclientCbipCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntclientCbipCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntclientCbipCounter
table
"
INDEX { pm200frs02CntclientCbipCounterIndex }
::= { pm200frs02CntclientCbipCounterTable 1 }
Pm200frs02CntclientCbipCounterEntry ::=
SEQUENCE {
pm200frs02CntclientCbipCounterIndex
INTEGER,
pm200frs02CntclientCbipCounterValuePortn
Counter32,
pm200frs02CntclientCbipCounterErrorPortn
EkiOnOff,
pm200frs02CntclientCbipCounterOverloadPortn
EkiOnOff
}
pm200frs02CntclientCbipCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntclientCbipCounter
table
"
::= { pm200frs02CntclientCbipCounterEntry 1 }
pm200frs02CntclientCbipCounterValuePortn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output Errors :This counter
gives the number of SM-BIP8 on
the client port (OTU4 only) <Help>
This counter gives the number
of SM-BIP8 on the client port
(OTU4 only)
"
::= { pm200frs02CntclientCbipCounterEntry 2 }
pm200frs02CntclientCbipCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Counter Error :This OID
when set indicates the BIP8 error
counter value is invalid on Port
"
::= { pm200frs02CntclientCbipCounterEntry 3 }
pm200frs02CntclientCbipCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client CBIP Counter Overload :This
OID when set indicates a BIP8 error
counter overload on Port
"
::= { pm200frs02CntclientCbipCounterEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntlocalLineSmBip8ErrorCounter articles
--- *********************************************************
pm200frs02CntlocalLineSmBip8ErrorCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntlocalLineSmBip8ErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntlocalLineSmBip8ErrorCounter
Article
"
::= { pm200frs02CntLine 192 }
pm200frs02CntlocalLineSmBip8ErrorCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntlocalLineSmBip8ErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntlocalLineSmBip8ErrorCounter
table
"
INDEX { pm200frs02CntlocalLineSmBip8ErrorCounterIndex }
::= { pm200frs02CntlocalLineSmBip8ErrorCounterTable 1 }
Pm200frs02CntlocalLineSmBip8ErrorCounterEntry ::=
SEQUENCE {
pm200frs02CntlocalLineSmBip8ErrorCounterIndex
INTEGER,
pm200frs02CntlocalLineSmBip8ErrorCounterValuePortn
Counter64,
pm200frs02CntlocalLineSmBip8ErrorCounterErrorPortn
EkiOnOff,
pm200frs02CntlocalLineSmBip8ErrorCounterOverloadPortn
EkiOnOff
}
pm200frs02CntlocalLineSmBip8ErrorCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntlocalLineSmBip8ErrorCounter
table
"
::= { pm200frs02CntlocalLineSmBip8ErrorCounterEntry 1 }
pm200frs02CntlocalLineSmBip8ErrorCounterValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Uncorrected FEC Errors :This OID
gives the current Bit Error Rate
(residual SM-BIP8 error) after
FEC <Help> This counter gives
the current Bit Error Rate (residual
SM-BIP8 error) after FEC
"
::= { pm200frs02CntlocalLineSmBip8ErrorCounterEntry 2 }
pm200frs02CntlocalLineSmBip8ErrorCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Error :This OID when
set indicates the B1 error counter
value is invalid on Port
"
::= { pm200frs02CntlocalLineSmBip8ErrorCounterEntry 3 }
pm200frs02CntlocalLineSmBip8ErrorCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Overload :This OID
when set indicates a B1 error counter
overload on Port
"
::= { pm200frs02CntlocalLineSmBip8ErrorCounterEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntlocalLineFecCorrectedErrorsCounter articles
--- *********************************************************
pm200frs02CntlocalLineFecCorrectedErrorsCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntlocalLineFecCorrectedErrorsCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntlocalLineFecCorrectedErrorsCounter
Article
"
::= { pm200frs02CntLine 193 }
pm200frs02CntlocalLineFecCorrectedErrorsCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntlocalLineFecCorrectedErrorsCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntlocalLineFecCorrectedErrorsCounter
table
"
INDEX { pm200frs02CntlocalLineFecCorrectedErrorsCounterIndex }
::= { pm200frs02CntlocalLineFecCorrectedErrorsCounterTable 1 }
Pm200frs02CntlocalLineFecCorrectedErrorsCounterEntry ::=
SEQUENCE {
pm200frs02CntlocalLineFecCorrectedErrorsCounterIndex
INTEGER,
pm200frs02CntlocalLineFecCorrectedErrorsCounterValuePortn
Counter64,
pm200frs02CntlocalLineFecCorrectedErrorsCounterErrorPortn
EkiOnOff,
pm200frs02CntlocalLineFecCorrectedErrorsCounterOverloadPortn
EkiOnOff
}
pm200frs02CntlocalLineFecCorrectedErrorsCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntlocalLineFecCorrectedErrorsCounter
table
"
::= { pm200frs02CntlocalLineFecCorrectedErrorsCounterEntry 1 }
pm200frs02CntlocalLineFecCorrectedErrorsCounterValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Input HD FEC Corrected Errors
:This OID gives the current Bit
Error Rate before the Hard Decision
FEC <Help> This counter gives
the current Bit Error Rate before
the Hard Decision FEC
"
::= { pm200frs02CntlocalLineFecCorrectedErrorsCounterEntry 2 }
pm200frs02CntlocalLineFecCorrectedErrorsCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
FEC Counter Error :This bit when
set indicates the FEC corrected
errors counter value is invalid
on Line
"
::= { pm200frs02CntlocalLineFecCorrectedErrorsCounterEntry 3 }
pm200frs02CntlocalLineFecCorrectedErrorsCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
FEC Counter Overload :This bit
when set indicates a FEC corrected
errors counter overload on Line
"
::= { pm200frs02CntlocalLineFecCorrectedErrorsCounterEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntremoteLineSmBip8ErrorCounter articles
--- *********************************************************
pm200frs02CntremoteLineSmBip8ErrorCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntremoteLineSmBip8ErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntremoteLineSmBip8ErrorCounter
Article
"
::= { pm200frs02CntLine 194 }
pm200frs02CntremoteLineSmBip8ErrorCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntremoteLineSmBip8ErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntremoteLineSmBip8ErrorCounter
table
"
INDEX { pm200frs02CntremoteLineSmBip8ErrorCounterIndex }
::= { pm200frs02CntremoteLineSmBip8ErrorCounterTable 1 }
Pm200frs02CntremoteLineSmBip8ErrorCounterEntry ::=
SEQUENCE {
pm200frs02CntremoteLineSmBip8ErrorCounterIndex
INTEGER,
pm200frs02CntremoteLineSmBip8ErrorCounterValuePortn
Counter64,
pm200frs02CntremoteLineSmBip8ErrorCounterErrorPortn
EkiOnOff,
pm200frs02CntremoteLineSmBip8ErrorCounterOverloadPortn
EkiOnOff
}
pm200frs02CntremoteLineSmBip8ErrorCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntremoteLineSmBip8ErrorCounter
table
"
::= { pm200frs02CntremoteLineSmBip8ErrorCounterEntry 1 }
pm200frs02CntremoteLineSmBip8ErrorCounterValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Remote SM BIP8 :This OID gives
the current Bit Error Rate (residual
SM-BIP8 error) after FEC on the
remote side <Help> This counter
gives the current Bit Error Rate
(residual SM-BIP8 error) after
FEC on the remote side
"
::= { pm200frs02CntremoteLineSmBip8ErrorCounterEntry 2 }
pm200frs02CntremoteLineSmBip8ErrorCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Remote Counter Error :
"
::= { pm200frs02CntremoteLineSmBip8ErrorCounterEntry 3 }
pm200frs02CntremoteLineSmBip8ErrorCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Remote Counter Overload :
"
::= { pm200frs02CntremoteLineSmBip8ErrorCounterEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntlineDfrmTimCnt articles
--- *********************************************************
pm200frs02CntlineDfrmTimCntTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntlineDfrmTimCntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntlineDfrmTimCnt
Article
"
::= { pm200frs02CntLine 195 }
pm200frs02CntlineDfrmTimCntEntry OBJECT-TYPE
SYNTAX Pm200frs02CntlineDfrmTimCntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntlineDfrmTimCnt
table
"
INDEX { pm200frs02CntlineDfrmTimCntIndex }
::= { pm200frs02CntlineDfrmTimCntTable 1 }
Pm200frs02CntlineDfrmTimCntEntry ::=
SEQUENCE {
pm200frs02CntlineDfrmTimCntIndex
INTEGER,
pm200frs02CntlineDfrmTimCntValuePortn
Counter64,
pm200frs02CntlineDfrmTimCntErrorPortn
EkiOnOff,
pm200frs02CntlineDfrmTimCntOverloadPortn
EkiOnOff
}
pm200frs02CntlineDfrmTimCntIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntlineDfrmTimCnt
table
"
::= { pm200frs02CntlineDfrmTimCntEntry 1 }
pm200frs02CntlineDfrmTimCntValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Timer Counter :
"
::= { pm200frs02CntlineDfrmTimCntEntry 2 }
pm200frs02CntlineDfrmTimCntErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Error :This OID when
set indicates the deframer timer
counter value is invalid on Port
"
::= { pm200frs02CntlineDfrmTimCntEntry 3 }
pm200frs02CntlineDfrmTimCntOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Overload :This OID
when set indicates a deframer timer
counter overload on Port
"
::= { pm200frs02CntlineDfrmTimCntEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntlocalLineTrscvPreSdFecErrorCounter articles
--- *********************************************************
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntlocalLineTrscvPreSdFecErrorCounter
Article
"
::= { pm200frs02CntLine 196 }
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntlocalLineTrscvPreSdFecErrorCounter
table
"
INDEX { pm200frs02CntlocalLineTrscvPreSdFecErrorCounterIndex }
::= { pm200frs02CntlocalLineTrscvPreSdFecErrorCounterTable 1 }
Pm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry ::=
SEQUENCE {
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterIndex
INTEGER,
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterValuePortn
Counter64,
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterErrorPortn
EkiOnOff,
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterOverloadPortn
EkiOnOff
}
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntlocalLineTrscvPreSdFecErrorCounter
table
"
::= { pm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry 1 }
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre FEC Errors :This OID gives
the current Bit Error Rate before
the FEC <Help> This counter gives
the current Bit Error Rate before
the FEC
"
::= { pm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry 2 }
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Error :This OID when
set indicates the deframer timer
counter value is invalid on Port
"
::= { pm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry 3 }
pm200frs02CntlocalLineTrscvPreSdFecErrorCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Overload :This OID
when set indicates a deframer timer
counter overload on Port
"
::= { pm200frs02CntlocalLineTrscvPreSdFecErrorCounterEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounter articles
--- *********************************************************
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounter
Article
"
::= { pm200frs02CntLine 197 }
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounter
table
"
INDEX { pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterIndex }
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterTable 1 }
Pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry ::=
SEQUENCE {
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterIndex
INTEGER,
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortn
Counter64,
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortn
EkiOnOff,
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortn
EkiOnOff
}
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounter
table
"
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry 1 }
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Uncorrected FEC Errors :This OID
gives the current Bit Error Rate
after the Soft Decision FEC (residual)
<Help> This counter gives the
current Bit Error Rate after the
Soft Decision FEC (residual)
"
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry 2 }
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Error :This OID when
set indicates the deframer timer
counter value is invalid on Port
"
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry 3 }
pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Overload :This OID
when set indicates a deframer timer
counter overload on Port
"
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecErrorCounterEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntlocalLineTrscvPreSdFecBitCounter articles
--- *********************************************************
pm200frs02CntlocalLineTrscvPreSdFecBitCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntlocalLineTrscvPreSdFecBitCounter
Article
"
::= { pm200frs02CntLine 198 }
pm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntlocalLineTrscvPreSdFecBitCounter
table
"
INDEX { pm200frs02CntlocalLineTrscvPreSdFecBitCounterIndex }
::= { pm200frs02CntlocalLineTrscvPreSdFecBitCounterTable 1 }
Pm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry ::=
SEQUENCE {
pm200frs02CntlocalLineTrscvPreSdFecBitCounterIndex
INTEGER,
pm200frs02CntlocalLineTrscvPreSdFecBitCounterValuePortn
Counter64,
pm200frs02CntlocalLineTrscvPreSdFecBitCounterErrorPortn
EkiOnOff,
pm200frs02CntlocalLineTrscvPreSdFecBitCounterOverloadPortn
EkiOnOff
}
pm200frs02CntlocalLineTrscvPreSdFecBitCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntlocalLineTrscvPreSdFecBitCounter
table
"
::= { pm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry 1 }
pm200frs02CntlocalLineTrscvPreSdFecBitCounterValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-SD FEC Bit Counter :This OID
gives the current Bit count before
the Soft Decision FEC <Help> This
counter gives the current Bit Count
before the Soft Decision FEC
"
::= { pm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry 2 }
pm200frs02CntlocalLineTrscvPreSdFecBitCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Error :This OID when
set indicates the deframer timer
counter value is invalid on Port
"
::= { pm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry 3 }
pm200frs02CntlocalLineTrscvPreSdFecBitCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Overload :This OID
when set indicates a deframer timer
counter overload on Port
"
::= { pm200frs02CntlocalLineTrscvPreSdFecBitCounterEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounter articles
--- *********************************************************
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounter
Article
"
::= { pm200frs02CntLine 199 }
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry OBJECT-TYPE
SYNTAX Pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounter
table
"
INDEX { pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterIndex }
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterTable 1 }
Pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry ::=
SEQUENCE {
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterIndex
INTEGER,
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterValuePortn
Counter64,
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortn
EkiOnOff,
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortn
EkiOnOff
}
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounter
table
"
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry 1 }
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Uncorrected SD FEC Bit Counter
:This OID gives the current Bit
count after the Soft Decision FEC
(residual) <Help> This counter
gives the current Bit Count after
the Soft Decision FEC (residual)
"
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry 2 }
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Error :This OID when
set indicates the deframer timer
counter value is invalid on Port
"
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry 3 }
pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Counter Overload :This OID
when set indicates a deframer timer
counter overload on Port
"
::= { pm200frs02CntlocalLineTrscvUncorrectedSdFecBitCounterEntry 4 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- RMON - 64 bits COUNTERS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02MonupRmonBytesCounterClientInput articles
--- *********************************************************
pm200frs02MonupRmonBytesCounterClientInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MonupRmonBytesCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MonupRmonBytesCounterClientInput
Article
"
::= { pm200frs02MonClientRmonCounter 16 }
pm200frs02MonupRmonBytesCounterClientInputEntry OBJECT-TYPE
SYNTAX Pm200frs02MonupRmonBytesCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MonupRmonBytesCounterClientInput
table
"
INDEX { pm200frs02MonupRmonBytesCounterClientInputIndex }
::= { pm200frs02MonupRmonBytesCounterClientInputTable 1 }
Pm200frs02MonupRmonBytesCounterClientInputEntry ::=
SEQUENCE {
pm200frs02MonupRmonBytesCounterClientInputIndex
INTEGER,
pm200frs02MonupRmonBytesCounterClientInputValuePortn
Counter64,
pm200frs02MonupRmonBytesCounterClientInputErrorPortn
EkiOnOff,
pm200frs02MonupRmonBytesCounterClientInputOverloadPortn
EkiOnOff
}
pm200frs02MonupRmonBytesCounterClientInputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MonupRmonBytesCounterClientInput
table
"
::= { pm200frs02MonupRmonBytesCounterClientInputEntry 1 }
pm200frs02MonupRmonBytesCounterClientInputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Bytes :This counter
is increased each time a data byte
is received on the client port
<Help> This counter gives the
number of bytes received on the
client port
"
::= { pm200frs02MonupRmonBytesCounterClientInputEntry 2 }
pm200frs02MonupRmonBytesCounterClientInputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Bytes Counter Error :This OID
when set indicates the Bytes counter
value is invalid on client port
"
::= { pm200frs02MonupRmonBytesCounterClientInputEntry 3 }
pm200frs02MonupRmonBytesCounterClientInputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Bytes Counter Overload :This OID
when set indicates a Bytes counter
overload on client port
"
::= { pm200frs02MonupRmonBytesCounterClientInputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MonupRmonCrcErrorsCounterClientInput articles
--- *********************************************************
pm200frs02MonupRmonCrcErrorsCounterClientInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MonupRmonCrcErrorsCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MonupRmonCrcErrorsCounterClientInput
Article
"
::= { pm200frs02MonClientRmonCounter 48 }
pm200frs02MonupRmonCrcErrorsCounterClientInputEntry OBJECT-TYPE
SYNTAX Pm200frs02MonupRmonCrcErrorsCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MonupRmonCrcErrorsCounterClientInput
table
"
INDEX { pm200frs02MonupRmonCrcErrorsCounterClientInputIndex }
::= { pm200frs02MonupRmonCrcErrorsCounterClientInputTable 1 }
Pm200frs02MonupRmonCrcErrorsCounterClientInputEntry ::=
SEQUENCE {
pm200frs02MonupRmonCrcErrorsCounterClientInputIndex
INTEGER,
pm200frs02MonupRmonCrcErrorsCounterClientInputValuePortn
Counter64,
pm200frs02MonupRmonCrcErrorsCounterClientInputErrorPortn
EkiOnOff,
pm200frs02MonupRmonCrcErrorsCounterClientInputOverloadPortn
EkiOnOff
}
pm200frs02MonupRmonCrcErrorsCounterClientInputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MonupRmonCrcErrorsCounterClientInput
table
"
::= { pm200frs02MonupRmonCrcErrorsCounterClientInputEntry 1 }
pm200frs02MonupRmonCrcErrorsCounterClientInputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input CRC Errors :This
counter is increased each time
a CRC error is detected on the
client port<Help> This counter
gives the number of CRC Errors
received on the client port
"
::= { pm200frs02MonupRmonCrcErrorsCounterClientInputEntry 2 }
pm200frs02MonupRmonCrcErrorsCounterClientInputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
CRC Errors Counter Error :This
OID when set indicates the CRC
Errors counter value is invalid
on client port
"
::= { pm200frs02MonupRmonCrcErrorsCounterClientInputEntry 3 }
pm200frs02MonupRmonCrcErrorsCounterClientInputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
CRC Errors Counter Overload :This
OID when set indicates a CRC Errors
counter overload on client port
"
::= { pm200frs02MonupRmonCrcErrorsCounterClientInputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MonupRmonPacketsCounterClientInput articles
--- *********************************************************
pm200frs02MonupRmonPacketsCounterClientInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MonupRmonPacketsCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MonupRmonPacketsCounterClientInput
Article
"
::= { pm200frs02MonClientRmonCounter 80 }
pm200frs02MonupRmonPacketsCounterClientInputEntry OBJECT-TYPE
SYNTAX Pm200frs02MonupRmonPacketsCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MonupRmonPacketsCounterClientInput
table
"
INDEX { pm200frs02MonupRmonPacketsCounterClientInputIndex }
::= { pm200frs02MonupRmonPacketsCounterClientInputTable 1 }
Pm200frs02MonupRmonPacketsCounterClientInputEntry ::=
SEQUENCE {
pm200frs02MonupRmonPacketsCounterClientInputIndex
INTEGER,
pm200frs02MonupRmonPacketsCounterClientInputValuePortn
Counter64,
pm200frs02MonupRmonPacketsCounterClientInputErrorPortn
EkiOnOff,
pm200frs02MonupRmonPacketsCounterClientInputOverloadPortn
EkiOnOff
}
pm200frs02MonupRmonPacketsCounterClientInputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MonupRmonPacketsCounterClientInput
table
"
::= { pm200frs02MonupRmonPacketsCounterClientInputEntry 1 }
pm200frs02MonupRmonPacketsCounterClientInputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Packets :This counter
is increased each time a packet
is received on the client port
<Help> This counter gives the
number of packets received on the
client port
"
::= { pm200frs02MonupRmonPacketsCounterClientInputEntry 2 }
pm200frs02MonupRmonPacketsCounterClientInputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Packets Counter Error :This OID
when set indicates the Packets
counter value is invalid on client
port
"
::= { pm200frs02MonupRmonPacketsCounterClientInputEntry 3 }
pm200frs02MonupRmonPacketsCounterClientInputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Packets Counter Overload :This
OID when set indicates a Packets
counter overload on client port
"
::= { pm200frs02MonupRmonPacketsCounterClientInputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MonupRmonBroadcastCounterClientInput articles
--- *********************************************************
pm200frs02MonupRmonBroadcastCounterClientInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MonupRmonBroadcastCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MonupRmonBroadcastCounterClientInput
Article
"
::= { pm200frs02MonClientRmonCounter 112 }
pm200frs02MonupRmonBroadcastCounterClientInputEntry OBJECT-TYPE
SYNTAX Pm200frs02MonupRmonBroadcastCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MonupRmonBroadcastCounterClientInput
table
"
INDEX { pm200frs02MonupRmonBroadcastCounterClientInputIndex }
::= { pm200frs02MonupRmonBroadcastCounterClientInputTable 1 }
Pm200frs02MonupRmonBroadcastCounterClientInputEntry ::=
SEQUENCE {
pm200frs02MonupRmonBroadcastCounterClientInputIndex
INTEGER,
pm200frs02MonupRmonBroadcastCounterClientInputValuePortn
Counter64,
pm200frs02MonupRmonBroadcastCounterClientInputErrorPortn
EkiOnOff,
pm200frs02MonupRmonBroadcastCounterClientInputOverloadPortn
EkiOnOff
}
pm200frs02MonupRmonBroadcastCounterClientInputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MonupRmonBroadcastCounterClientInput
table
"
::= { pm200frs02MonupRmonBroadcastCounterClientInputEntry 1 }
pm200frs02MonupRmonBroadcastCounterClientInputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Broadcast Packets
:This counter is increased each
time a broadcast packet is received
on the client port <Help> This
counter gives the number of Broadcast
packets received on the client
port
"
::= { pm200frs02MonupRmonBroadcastCounterClientInputEntry 2 }
pm200frs02MonupRmonBroadcastCounterClientInputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Broadcast Counter Error :This
OID when set indicates the Broadcast
counter value is invalid on client
port
"
::= { pm200frs02MonupRmonBroadcastCounterClientInputEntry 3 }
pm200frs02MonupRmonBroadcastCounterClientInputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Broadcast Counter Overload :This
OID when set indicates a Broadcast
counter overload on client port
"
::= { pm200frs02MonupRmonBroadcastCounterClientInputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MonupRmonMulticastCounterClientInput articles
--- *********************************************************
pm200frs02MonupRmonMulticastCounterClientInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MonupRmonMulticastCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MonupRmonMulticastCounterClientInput
Article
"
::= { pm200frs02MonClientRmonCounter 144 }
pm200frs02MonupRmonMulticastCounterClientInputEntry OBJECT-TYPE
SYNTAX Pm200frs02MonupRmonMulticastCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MonupRmonMulticastCounterClientInput
table
"
INDEX { pm200frs02MonupRmonMulticastCounterClientInputIndex }
::= { pm200frs02MonupRmonMulticastCounterClientInputTable 1 }
Pm200frs02MonupRmonMulticastCounterClientInputEntry ::=
SEQUENCE {
pm200frs02MonupRmonMulticastCounterClientInputIndex
INTEGER,
pm200frs02MonupRmonMulticastCounterClientInputValuePortn
Counter64,
pm200frs02MonupRmonMulticastCounterClientInputErrorPortn
EkiOnOff,
pm200frs02MonupRmonMulticastCounterClientInputOverloadPortn
EkiOnOff
}
pm200frs02MonupRmonMulticastCounterClientInputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MonupRmonMulticastCounterClientInput
table
"
::= { pm200frs02MonupRmonMulticastCounterClientInputEntry 1 }
pm200frs02MonupRmonMulticastCounterClientInputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Multicast Packets
:This counter is increased each
time a Multicast packet is received
on the client port <Help> This
counter gives the number of Multicast
packets received on the client
port
"
::= { pm200frs02MonupRmonMulticastCounterClientInputEntry 2 }
pm200frs02MonupRmonMulticastCounterClientInputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Multicast Counter Error :This
OID when set indicates the Multicast
counter value is invalid on client
port
"
::= { pm200frs02MonupRmonMulticastCounterClientInputEntry 3 }
pm200frs02MonupRmonMulticastCounterClientInputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Multicast Counter Overload :This
OID when set indicates a Multicast
counter overload on client port
"
::= { pm200frs02MonupRmonMulticastCounterClientInputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MonupRmonPauseFrameCounterClientInput articles
--- *********************************************************
pm200frs02MonupRmonPauseFrameCounterClientInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MonupRmonPauseFrameCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MonupRmonPauseFrameCounterClientInput
Article
"
::= { pm200frs02MonClientRmonCounter 176 }
pm200frs02MonupRmonPauseFrameCounterClientInputEntry OBJECT-TYPE
SYNTAX Pm200frs02MonupRmonPauseFrameCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MonupRmonPauseFrameCounterClientInput
table
"
INDEX { pm200frs02MonupRmonPauseFrameCounterClientInputIndex }
::= { pm200frs02MonupRmonPauseFrameCounterClientInputTable 1 }
Pm200frs02MonupRmonPauseFrameCounterClientInputEntry ::=
SEQUENCE {
pm200frs02MonupRmonPauseFrameCounterClientInputIndex
INTEGER,
pm200frs02MonupRmonPauseFrameCounterClientInputValuePortn
Counter64,
pm200frs02MonupRmonPauseFrameCounterClientInputErrorPortn
EkiOnOff,
pm200frs02MonupRmonPauseFrameCounterClientInputOverloadPortn
EkiOnOff
}
pm200frs02MonupRmonPauseFrameCounterClientInputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MonupRmonPauseFrameCounterClientInput
table
"
::= { pm200frs02MonupRmonPauseFrameCounterClientInputEntry 1 }
pm200frs02MonupRmonPauseFrameCounterClientInputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Pause Frames :This
counter is increased each time
a Pause frame is received on the
client port <Help> This counter
gives the number of Pause frames
received on the client port
"
::= { pm200frs02MonupRmonPauseFrameCounterClientInputEntry 2 }
pm200frs02MonupRmonPauseFrameCounterClientInputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pause Counter Error :This OID
when set indicates the Pause counter
value is invalid on client port
"
::= { pm200frs02MonupRmonPauseFrameCounterClientInputEntry 3 }
pm200frs02MonupRmonPauseFrameCounterClientInputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pause Counter Overload :This OID
when set indicates a Pause counter
overload on client port
"
::= { pm200frs02MonupRmonPauseFrameCounterClientInputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MonupRmonUnicastCounterClientInput articles
--- *********************************************************
pm200frs02MonupRmonUnicastCounterClientInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MonupRmonUnicastCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MonupRmonUnicastCounterClientInput
Article
"
::= { pm200frs02MonClientRmonCounter 304 }
pm200frs02MonupRmonUnicastCounterClientInputEntry OBJECT-TYPE
SYNTAX Pm200frs02MonupRmonUnicastCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MonupRmonUnicastCounterClientInput
table
"
INDEX { pm200frs02MonupRmonUnicastCounterClientInputIndex }
::= { pm200frs02MonupRmonUnicastCounterClientInputTable 1 }
Pm200frs02MonupRmonUnicastCounterClientInputEntry ::=
SEQUENCE {
pm200frs02MonupRmonUnicastCounterClientInputIndex
INTEGER,
pm200frs02MonupRmonUnicastCounterClientInputValuePortn
Counter64,
pm200frs02MonupRmonUnicastCounterClientInputErrorPortn
EkiOnOff,
pm200frs02MonupRmonUnicastCounterClientInputOverloadPortn
EkiOnOff
}
pm200frs02MonupRmonUnicastCounterClientInputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MonupRmonUnicastCounterClientInput
table
"
::= { pm200frs02MonupRmonUnicastCounterClientInputEntry 1 }
pm200frs02MonupRmonUnicastCounterClientInputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Unicast Packets :This
counter is increased each time
a Unicast packet is received on
the client port <Help> This counter
gives the number of Unicast packets
received on the client port
"
::= { pm200frs02MonupRmonUnicastCounterClientInputEntry 2 }
pm200frs02MonupRmonUnicastCounterClientInputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Unicast Counter Error :This OID
when set indicates the Unicast
counter value is invalid on client
port
"
::= { pm200frs02MonupRmonUnicastCounterClientInputEntry 3 }
pm200frs02MonupRmonUnicastCounterClientInputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Unicast Counter Overload :This
OID when set indicates a Unicast
counter overload on client port
"
::= { pm200frs02MonupRmonUnicastCounterClientInputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MonupRmonNonunicastCounterClientInput articles
--- *********************************************************
pm200frs02MonupRmonNonunicastCounterClientInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MonupRmonNonunicastCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MonupRmonNonunicastCounterClientInput
Article
"
::= { pm200frs02MonClientRmonCounter 336 }
pm200frs02MonupRmonNonunicastCounterClientInputEntry OBJECT-TYPE
SYNTAX Pm200frs02MonupRmonNonunicastCounterClientInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MonupRmonNonunicastCounterClientInput
table
"
INDEX { pm200frs02MonupRmonNonunicastCounterClientInputIndex }
::= { pm200frs02MonupRmonNonunicastCounterClientInputTable 1 }
Pm200frs02MonupRmonNonunicastCounterClientInputEntry ::=
SEQUENCE {
pm200frs02MonupRmonNonunicastCounterClientInputIndex
INTEGER,
pm200frs02MonupRmonNonunicastCounterClientInputValuePortn
Counter64,
pm200frs02MonupRmonNonunicastCounterClientInputErrorPortn
EkiOnOff,
pm200frs02MonupRmonNonunicastCounterClientInputOverloadPortn
EkiOnOff
}
pm200frs02MonupRmonNonunicastCounterClientInputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MonupRmonNonunicastCounterClientInput
table
"
::= { pm200frs02MonupRmonNonunicastCounterClientInputEntry 1 }
pm200frs02MonupRmonNonunicastCounterClientInputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Input Non Unicast Packets
:This counter is increased each
time a Non-Unicast packet is received
on the client port <Help> This
counter gives the number of Non-Unicast
packets received on the client
port
"
::= { pm200frs02MonupRmonNonunicastCounterClientInputEntry 2 }
pm200frs02MonupRmonNonunicastCounterClientInputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Non Unicast Counter Error :This
OID when set indicates the Non-Unicast
counter value is invalid on client
port
"
::= { pm200frs02MonupRmonNonunicastCounterClientInputEntry 3 }
pm200frs02MonupRmonNonunicastCounterClientInputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Non Unicast Counter Overload :This
OID when set indicates a Non-Unicast
counter overload on client port
"
::= { pm200frs02MonupRmonNonunicastCounterClientInputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MondownRmonBytesCounterClientOutput articles
--- *********************************************************
pm200frs02MondownRmonBytesCounterClientOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MondownRmonBytesCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MondownRmonBytesCounterClientOutput
Article
"
::= { pm200frs02MonClientRmonCounter 400 }
pm200frs02MondownRmonBytesCounterClientOutputEntry OBJECT-TYPE
SYNTAX Pm200frs02MondownRmonBytesCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MondownRmonBytesCounterClientOutput
table
"
INDEX { pm200frs02MondownRmonBytesCounterClientOutputIndex }
::= { pm200frs02MondownRmonBytesCounterClientOutputTable 1 }
Pm200frs02MondownRmonBytesCounterClientOutputEntry ::=
SEQUENCE {
pm200frs02MondownRmonBytesCounterClientOutputIndex
INTEGER,
pm200frs02MondownRmonBytesCounterClientOutputValuePortn
Counter64,
pm200frs02MondownRmonBytesCounterClientOutputErrorPortn
EkiOnOff,
pm200frs02MondownRmonBytesCounterClientOutputOverloadPortn
EkiOnOff
}
pm200frs02MondownRmonBytesCounterClientOutputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MondownRmonBytesCounterClientOutput
table
"
::= { pm200frs02MondownRmonBytesCounterClientOutputEntry 1 }
pm200frs02MondownRmonBytesCounterClientOutputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output Bytes :This counter
is increased each time a data byte
is transmitted on the client port
<Help> This counter gives the number
of bytes transmitted on the client
port
"
::= { pm200frs02MondownRmonBytesCounterClientOutputEntry 2 }
pm200frs02MondownRmonBytesCounterClientOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Bytes Counter Error :This OID
when set indicates the Bytes counter
value is invalid on client port
"
::= { pm200frs02MondownRmonBytesCounterClientOutputEntry 3 }
pm200frs02MondownRmonBytesCounterClientOutputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Bytes Counter Overload :This OID
when set indicates a Bytes counter
overload on client port
"
::= { pm200frs02MondownRmonBytesCounterClientOutputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MondownRmonCrcErrorsCounterClientOutput articles
--- *********************************************************
pm200frs02MondownRmonCrcErrorsCounterClientOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MondownRmonCrcErrorsCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MondownRmonCrcErrorsCounterClientOutput
Article
"
::= { pm200frs02MonClientRmonCounter 432 }
pm200frs02MondownRmonCrcErrorsCounterClientOutputEntry OBJECT-TYPE
SYNTAX Pm200frs02MondownRmonCrcErrorsCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MondownRmonCrcErrorsCounterClientOutput
table
"
INDEX { pm200frs02MondownRmonCrcErrorsCounterClientOutputIndex }
::= { pm200frs02MondownRmonCrcErrorsCounterClientOutputTable 1 }
Pm200frs02MondownRmonCrcErrorsCounterClientOutputEntry ::=
SEQUENCE {
pm200frs02MondownRmonCrcErrorsCounterClientOutputIndex
INTEGER,
pm200frs02MondownRmonCrcErrorsCounterClientOutputValuePortn
Counter64,
pm200frs02MondownRmonCrcErrorsCounterClientOutputErrorPortn
EkiOnOff,
pm200frs02MondownRmonCrcErrorsCounterClientOutputOverloadPortn
EkiOnOff
}
pm200frs02MondownRmonCrcErrorsCounterClientOutputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MondownRmonCrcErrorsCounterClientOutput
table
"
::= { pm200frs02MondownRmonCrcErrorsCounterClientOutputEntry 1 }
pm200frs02MondownRmonCrcErrorsCounterClientOutputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output CRC Errors :This
counter is increased each time
a CRC error is detected on the
transmit client port <Help> This
counter gives the number of CRC
Errors transmitted on the client
port
"
::= { pm200frs02MondownRmonCrcErrorsCounterClientOutputEntry 2 }
pm200frs02MondownRmonCrcErrorsCounterClientOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
CRC Errors Counter Error :This
OID when set indicates the CRC
Errors counter value is invalid
on client port
"
::= { pm200frs02MondownRmonCrcErrorsCounterClientOutputEntry 3 }
pm200frs02MondownRmonCrcErrorsCounterClientOutputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
CRC Errors Counter Overload :This
OID when set indicates a CRC Errors
counter overload on client port
"
::= { pm200frs02MondownRmonCrcErrorsCounterClientOutputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MondownRmonPacketsCounterClientOutput articles
--- *********************************************************
pm200frs02MondownRmonPacketsCounterClientOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MondownRmonPacketsCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MondownRmonPacketsCounterClientOutput
Article
"
::= { pm200frs02MonClientRmonCounter 464 }
pm200frs02MondownRmonPacketsCounterClientOutputEntry OBJECT-TYPE
SYNTAX Pm200frs02MondownRmonPacketsCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MondownRmonPacketsCounterClientOutput
table
"
INDEX { pm200frs02MondownRmonPacketsCounterClientOutputIndex }
::= { pm200frs02MondownRmonPacketsCounterClientOutputTable 1 }
Pm200frs02MondownRmonPacketsCounterClientOutputEntry ::=
SEQUENCE {
pm200frs02MondownRmonPacketsCounterClientOutputIndex
INTEGER,
pm200frs02MondownRmonPacketsCounterClientOutputValuePortn
Counter64,
pm200frs02MondownRmonPacketsCounterClientOutputErrorPortn
EkiOnOff,
pm200frs02MondownRmonPacketsCounterClientOutputOverloadPortn
EkiOnOff
}
pm200frs02MondownRmonPacketsCounterClientOutputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MondownRmonPacketsCounterClientOutput
table
"
::= { pm200frs02MondownRmonPacketsCounterClientOutputEntry 1 }
pm200frs02MondownRmonPacketsCounterClientOutputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output Packets :This counter
is increased each time a packet
is transmitted on the client port
<Help> This counter gives the
number of packets transmitted on
the client port
"
::= { pm200frs02MondownRmonPacketsCounterClientOutputEntry 2 }
pm200frs02MondownRmonPacketsCounterClientOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Packets Counter Error :This OID
when set indicates the Packets
counter value is invalid on client
port
"
::= { pm200frs02MondownRmonPacketsCounterClientOutputEntry 3 }
pm200frs02MondownRmonPacketsCounterClientOutputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Packets Counter Overload :This
OID when set indicates a Packets
counter overload on client port
"
::= { pm200frs02MondownRmonPacketsCounterClientOutputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MondownRmonBroadcastCounterClientOutput articles
--- *********************************************************
pm200frs02MondownRmonBroadcastCounterClientOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MondownRmonBroadcastCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MondownRmonBroadcastCounterClientOutput
Article
"
::= { pm200frs02MonClientRmonCounter 496 }
pm200frs02MondownRmonBroadcastCounterClientOutputEntry OBJECT-TYPE
SYNTAX Pm200frs02MondownRmonBroadcastCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MondownRmonBroadcastCounterClientOutput
table
"
INDEX { pm200frs02MondownRmonBroadcastCounterClientOutputIndex }
::= { pm200frs02MondownRmonBroadcastCounterClientOutputTable 1 }
Pm200frs02MondownRmonBroadcastCounterClientOutputEntry ::=
SEQUENCE {
pm200frs02MondownRmonBroadcastCounterClientOutputIndex
INTEGER,
pm200frs02MondownRmonBroadcastCounterClientOutputValuePortn
Counter64,
pm200frs02MondownRmonBroadcastCounterClientOutputErrorPortn
EkiOnOff,
pm200frs02MondownRmonBroadcastCounterClientOutputOverloadPortn
EkiOnOff
}
pm200frs02MondownRmonBroadcastCounterClientOutputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MondownRmonBroadcastCounterClientOutput
table
"
::= { pm200frs02MondownRmonBroadcastCounterClientOutputEntry 1 }
pm200frs02MondownRmonBroadcastCounterClientOutputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output Broadcast Packets
:This counter is increased each
time a broadcast packet is transmitted
on the client port <Help> This
counter gives the number of Broadcast
packets transmitted on the client
port
"
::= { pm200frs02MondownRmonBroadcastCounterClientOutputEntry 2 }
pm200frs02MondownRmonBroadcastCounterClientOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Broadcast Counter Error :This
OID when set indicates the Broadcast
counter value is invalid on client
port
"
::= { pm200frs02MondownRmonBroadcastCounterClientOutputEntry 3 }
pm200frs02MondownRmonBroadcastCounterClientOutputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Broadcast Counter Overload :This
OID when set indicates a Broadcast
counter overload on client port
"
::= { pm200frs02MondownRmonBroadcastCounterClientOutputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MondownRmonMulticastCounterClientOutput articles
--- *********************************************************
pm200frs02MondownRmonMulticastCounterClientOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MondownRmonMulticastCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MondownRmonMulticastCounterClientOutput
Article
"
::= { pm200frs02MonClientRmonCounter 528 }
pm200frs02MondownRmonMulticastCounterClientOutputEntry OBJECT-TYPE
SYNTAX Pm200frs02MondownRmonMulticastCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MondownRmonMulticastCounterClientOutput
table
"
INDEX { pm200frs02MondownRmonMulticastCounterClientOutputIndex }
::= { pm200frs02MondownRmonMulticastCounterClientOutputTable 1 }
Pm200frs02MondownRmonMulticastCounterClientOutputEntry ::=
SEQUENCE {
pm200frs02MondownRmonMulticastCounterClientOutputIndex
INTEGER,
pm200frs02MondownRmonMulticastCounterClientOutputValuePortn
Counter64,
pm200frs02MondownRmonMulticastCounterClientOutputErrorPortn
EkiOnOff,
pm200frs02MondownRmonMulticastCounterClientOutputOverloadPortn
EkiOnOff
}
pm200frs02MondownRmonMulticastCounterClientOutputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MondownRmonMulticastCounterClientOutput
table
"
::= { pm200frs02MondownRmonMulticastCounterClientOutputEntry 1 }
pm200frs02MondownRmonMulticastCounterClientOutputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output Multicast Packets
:This counter is increased each
time a Multicast packet is transmitted
on the client port <Help> This
counter gives the number of Multicast
packets transmitted on the client
port
"
::= { pm200frs02MondownRmonMulticastCounterClientOutputEntry 2 }
pm200frs02MondownRmonMulticastCounterClientOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Multicast Counter Error :This
OID when set indicates the Multicast
counter value is invalid on client
port
"
::= { pm200frs02MondownRmonMulticastCounterClientOutputEntry 3 }
pm200frs02MondownRmonMulticastCounterClientOutputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Multicast Counter Overload :This
OID when set indicates a Multicast
counter overload on client port
"
::= { pm200frs02MondownRmonMulticastCounterClientOutputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MondownRmonPauseFrameCounterClientOutput articles
--- *********************************************************
pm200frs02MondownRmonPauseFrameCounterClientOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MondownRmonPauseFrameCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MondownRmonPauseFrameCounterClientOutput
Article
"
::= { pm200frs02MonClientRmonCounter 560 }
pm200frs02MondownRmonPauseFrameCounterClientOutputEntry OBJECT-TYPE
SYNTAX Pm200frs02MondownRmonPauseFrameCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MondownRmonPauseFrameCounterClientOutput
table
"
INDEX { pm200frs02MondownRmonPauseFrameCounterClientOutputIndex }
::= { pm200frs02MondownRmonPauseFrameCounterClientOutputTable 1 }
Pm200frs02MondownRmonPauseFrameCounterClientOutputEntry ::=
SEQUENCE {
pm200frs02MondownRmonPauseFrameCounterClientOutputIndex
INTEGER,
pm200frs02MondownRmonPauseFrameCounterClientOutputValuePortn
Counter64,
pm200frs02MondownRmonPauseFrameCounterClientOutputErrorPortn
EkiOnOff,
pm200frs02MondownRmonPauseFrameCounterClientOutputOverloadPortn
EkiOnOff
}
pm200frs02MondownRmonPauseFrameCounterClientOutputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MondownRmonPauseFrameCounterClientOutput
table
"
::= { pm200frs02MondownRmonPauseFrameCounterClientOutputEntry 1 }
pm200frs02MondownRmonPauseFrameCounterClientOutputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output Pause Frames :This
counter is increased each time
a Pause frame is transmitted on
the client port <Help> This counter
gives the number of Pause frames
transmitted on the client port
"
::= { pm200frs02MondownRmonPauseFrameCounterClientOutputEntry 2 }
pm200frs02MondownRmonPauseFrameCounterClientOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pause Counter Error :This OID
when set indicates the Pause counter
value is invalid on client port
"
::= { pm200frs02MondownRmonPauseFrameCounterClientOutputEntry 3 }
pm200frs02MondownRmonPauseFrameCounterClientOutputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pause Counter Overload :This OID
when set indicates a Pause counter
overload on client port
"
::= { pm200frs02MondownRmonPauseFrameCounterClientOutputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MondownRmonUnicastCounterClientOutput articles
--- *********************************************************
pm200frs02MondownRmonUnicastCounterClientOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MondownRmonUnicastCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MondownRmonUnicastCounterClientOutput
Article
"
::= { pm200frs02MonClientRmonCounter 688 }
pm200frs02MondownRmonUnicastCounterClientOutputEntry OBJECT-TYPE
SYNTAX Pm200frs02MondownRmonUnicastCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MondownRmonUnicastCounterClientOutput
table
"
INDEX { pm200frs02MondownRmonUnicastCounterClientOutputIndex }
::= { pm200frs02MondownRmonUnicastCounterClientOutputTable 1 }
Pm200frs02MondownRmonUnicastCounterClientOutputEntry ::=
SEQUENCE {
pm200frs02MondownRmonUnicastCounterClientOutputIndex
INTEGER,
pm200frs02MondownRmonUnicastCounterClientOutputValuePortn
Counter64,
pm200frs02MondownRmonUnicastCounterClientOutputErrorPortn
EkiOnOff,
pm200frs02MondownRmonUnicastCounterClientOutputOverloadPortn
EkiOnOff
}
pm200frs02MondownRmonUnicastCounterClientOutputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MondownRmonUnicastCounterClientOutput
table
"
::= { pm200frs02MondownRmonUnicastCounterClientOutputEntry 1 }
pm200frs02MondownRmonUnicastCounterClientOutputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output Unicast Packets
:This counter is increased each
time a Unicast packet is transmitted
on the client port <Help> This
counter gives the number of Unicast
packets transmitted on the client
port
"
::= { pm200frs02MondownRmonUnicastCounterClientOutputEntry 2 }
pm200frs02MondownRmonUnicastCounterClientOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Unicast Counter Error :This OID
when set indicates the Unicast
counter value is invalid on client
port
"
::= { pm200frs02MondownRmonUnicastCounterClientOutputEntry 3 }
pm200frs02MondownRmonUnicastCounterClientOutputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Unicast Counter Overload :This
OID when set indicates a Unicast
counter overload on client port
"
::= { pm200frs02MondownRmonUnicastCounterClientOutputEntry 4 }
--- *********************************************************
--- TABLE for the pm200frs02MondownRmonNonunicastCounterClientOutput articles
--- *********************************************************
pm200frs02MondownRmonNonunicastCounterClientOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MondownRmonNonunicastCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MondownRmonNonunicastCounterClientOutput
Article
"
::= { pm200frs02MonClientRmonCounter 720 }
pm200frs02MondownRmonNonunicastCounterClientOutputEntry OBJECT-TYPE
SYNTAX Pm200frs02MondownRmonNonunicastCounterClientOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MondownRmonNonunicastCounterClientOutput
table
"
INDEX { pm200frs02MondownRmonNonunicastCounterClientOutputIndex }
::= { pm200frs02MondownRmonNonunicastCounterClientOutputTable 1 }
Pm200frs02MondownRmonNonunicastCounterClientOutputEntry ::=
SEQUENCE {
pm200frs02MondownRmonNonunicastCounterClientOutputIndex
INTEGER,
pm200frs02MondownRmonNonunicastCounterClientOutputValuePortn
Counter64,
pm200frs02MondownRmonNonunicastCounterClientOutputErrorPortn
EkiOnOff,
pm200frs02MondownRmonNonunicastCounterClientOutputOverloadPortn
EkiOnOff
}
pm200frs02MondownRmonNonunicastCounterClientOutputIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MondownRmonNonunicastCounterClientOutput
table
"
::= { pm200frs02MondownRmonNonunicastCounterClientOutputEntry 1 }
pm200frs02MondownRmonNonunicastCounterClientOutputValuePortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Output Non Unicast Packets
:This counter is increased each
time a Non-Unicast packet is transmitted
on the client port <Help> This
counter gives the number of Non-Unicast
packets transmitted on the client
port
"
::= { pm200frs02MondownRmonNonunicastCounterClientOutputEntry 2 }
pm200frs02MondownRmonNonunicastCounterClientOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Non Unicast Counter Error :This
OID when set indicates the Non-Unicast
counter value is invalid on client
port
"
::= { pm200frs02MondownRmonNonunicastCounterClientOutputEntry 3 }
pm200frs02MondownRmonNonunicastCounterClientOutputOverloadPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Non Unicast Counter Overload :This
OID when set indicates a Non-Unicast
counter overload on client port
"
::= { pm200frs02MondownRmonNonunicastCounterClientOutputEntry 4 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pm200frs02Mesrsynth0 OBJECT-TYPE
SYNTAX EkiMeasureType
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"
Not Used :
"
::= { pm200frs02MesrOther 0 }
pm200frs02Mesrsynth1 OBJECT-TYPE
SYNTAX EkiMeasureType
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"
Not Used :
"
::= { pm200frs02MesrOther 1 }
--- *****************************************************
--- LEAF for the pmIntervalNumber article
--- *****************************************************
pm200frs02MesrpmIntervalNumber OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Interval Counter :
"
::= { pm200frs02MesrOther 7 }
--- *****************************************************
--- LEAF for the clientCfpTemp article
--- *****************************************************
pm200frs02MesrclientCfpTemp OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Trscv Temperature :This
OID gives the temperature value
of the Client Transceiver, read
from the DDM (Digital Diagnostic
Monitoring) (Temperature = AV_S16/256)
(Unit = C) <Help> This Measure
gives the temperature value of
the Client Transceiver
"
::= { pm200frs02MesrClient 8 }
--- *****************************************************
--- LEAF for the clientCfp3v3Voltage article
--- *****************************************************
pm200frs02MesrclientCfp3v3Voltage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Trscv Voltage :This OID
gives the 3V3 voltage value of
the Client Transceiver, read from
the DDM (Digital Diagnostic Monitoring)
(Voltage = AV_U16/10000) (Unit
= V) <Help> This Measure gives
the 3V3 voltage value of the Client
Transceiver
"
::= { pm200frs02MesrClient 9 }
--- *****************************************************
--- LEAF for the clientSoaBiasCurrent article
--- *****************************************************
pm200frs02MesrclientSoaBiasCurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Trscv SOA Bias :This OID
gives the SOA bias value of the
Client Transceiver, read from the
DDM (Digital Diagnostic Monitoring)
(Bias = AV_U16/500) (Unit = mA)
<Help> This Measure gives the SOA
bias value of the Client Transceiver
"
::= { pm200frs02MesrClient 10 }
--- *****************************************************
--- LEAF for the lineMsaTemp article
--- *****************************************************
pm200frs02MesrlineMsaTemp OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Temperature :This OID
gives the temperature value of
the Line Transceiver, read from
the DDM (Digital Diagnostic Monitoring)
(Temperature = AV_S16/256) (Unit
= C) <Help> This Measure gives
the temperature value of the Line
Transceiver.This temperature must
remain below 95 C for proper operation
"
::= { pm200frs02MesrLine 12 }
--- *****************************************************
--- LEAF for the lineMsa3v3Voltage article
--- *****************************************************
pm200frs02MesrlineMsa3v3Voltage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv Voltage :This OID gives
the 3V3 voltage value of the Line
Transceiver, read from the DDM
(Digital Diagnostic Monitoring)
(Voltage = AV_U16/10000) (Unit
= V) <Help> This Measure gives
the 3V3 voltage value of the Line
Transceiver
"
::= { pm200frs02MesrLine 13 }
--- *****************************************************
--- LEAF for the lineSoaBiasCurrent article
--- *****************************************************
pm200frs02MesrlineSoaBiasCurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Trscv SOA Bias :This OID
gives the SOA bias value of the
Line Transceiver,read from the
DDM (Digital Diagnostic Monitoring)
(Bias = AV_U16/500) (Unit = mA)
<Help> This Measure gives the SOA
bias value of the Line Transceiver
"
::= { pm200frs02MesrLine 14 }
--- *********************************************************
--- TABLE for the pm200frs02MesrclientTxPwrMin articles
--- *********************************************************
pm200frs02MesrclientTxPwrMinTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrclientTxPwrMinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrclientTxPwrMin
Article
"
::= { pm200frs02MesrClient 16 }
pm200frs02MesrclientTxPwrMinEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrclientTxPwrMinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrclientTxPwrMin
table
"
INDEX { pm200frs02MesrclientTxPwrMinIndex }
::= { pm200frs02MesrclientTxPwrMinTable 1 }
Pm200frs02MesrclientTxPwrMinEntry ::=
SEQUENCE {
pm200frs02MesrclientTxPwrMinIndex
INTEGER,
pm200frs02MesrclientTxPwrMinPortn
INTEGER
}
pm200frs02MesrclientTxPwrMinIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrclientTxPwrMin
table
"
::= { pm200frs02MesrclientTxPwrMinEntry 1 }
pm200frs02MesrclientTxPwrMinPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Client Trscv Tx Power Per
Lane :This OID gives the minimum
transmit power value among the
network lanes of the Client Transceiver,
read from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV_U16)-40)
(Unit = dBm) <Help> This Measure
gives the minimum transmit power
value among the network lanes of
the Client Transceiver
"
::= { pm200frs02MesrclientTxPwrMinEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrclientRxPwrMin articles
--- *********************************************************
pm200frs02MesrclientRxPwrMinTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrclientRxPwrMinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrclientRxPwrMin
Article
"
::= { pm200frs02MesrClient 48 }
pm200frs02MesrclientRxPwrMinEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrclientRxPwrMinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrclientRxPwrMin
table
"
INDEX { pm200frs02MesrclientRxPwrMinIndex }
::= { pm200frs02MesrclientRxPwrMinTable 1 }
Pm200frs02MesrclientRxPwrMinEntry ::=
SEQUENCE {
pm200frs02MesrclientRxPwrMinIndex
INTEGER,
pm200frs02MesrclientRxPwrMinPortn
INTEGER
}
pm200frs02MesrclientRxPwrMinIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrclientRxPwrMin
table
"
::= { pm200frs02MesrclientRxPwrMinEntry 1 }
pm200frs02MesrclientRxPwrMinPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Client Trscv Rx Power Per
Lane :This OID gives the minimum
receive power value among the network
lanes of the Client Transceiver,
read from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV_U16)-40)
(Unit = dBm) <Help> This Measure
gives the minimum receive power
value among the network lanes of
the Client Transceiver
"
::= { pm200frs02MesrclientRxPwrMinEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrclientTxPwrMax articles
--- *********************************************************
pm200frs02MesrclientTxPwrMaxTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrclientTxPwrMaxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrclientTxPwrMax
Article
"
::= { pm200frs02MesrClient 80 }
pm200frs02MesrclientTxPwrMaxEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrclientTxPwrMaxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrclientTxPwrMax
table
"
INDEX { pm200frs02MesrclientTxPwrMaxIndex }
::= { pm200frs02MesrclientTxPwrMaxTable 1 }
Pm200frs02MesrclientTxPwrMaxEntry ::=
SEQUENCE {
pm200frs02MesrclientTxPwrMaxIndex
INTEGER,
pm200frs02MesrclientTxPwrMaxPortn
INTEGER
}
pm200frs02MesrclientTxPwrMaxIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrclientTxPwrMax
table
"
::= { pm200frs02MesrclientTxPwrMaxEntry 1 }
pm200frs02MesrclientTxPwrMaxPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Client Trscv Tx Power Per
Lane :This OID gives the maximum
transmit power value among the
network lanes of the Client Transceiver,
read from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV_U16)-40)
(Unit = dBm) <Help> This Measure
gives the maximum transmit power
value among the network lanes of
the Client Transceiver
"
::= { pm200frs02MesrclientTxPwrMaxEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrclientRxPwrMax articles
--- *********************************************************
pm200frs02MesrclientRxPwrMaxTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrclientRxPwrMaxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrclientRxPwrMax
Article
"
::= { pm200frs02MesrClient 112 }
pm200frs02MesrclientRxPwrMaxEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrclientRxPwrMaxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrclientRxPwrMax
table
"
INDEX { pm200frs02MesrclientRxPwrMaxIndex }
::= { pm200frs02MesrclientRxPwrMaxTable 1 }
Pm200frs02MesrclientRxPwrMaxEntry ::=
SEQUENCE {
pm200frs02MesrclientRxPwrMaxIndex
INTEGER,
pm200frs02MesrclientRxPwrMaxPortn
INTEGER
}
pm200frs02MesrclientRxPwrMaxIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrclientRxPwrMax
table
"
::= { pm200frs02MesrclientRxPwrMaxEntry 1 }
pm200frs02MesrclientRxPwrMaxPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Client Trscv Rx Power Per
Lane :This OID gives the maximum
receive power value among the network
lanes of the Client Transceiver,
read in the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV_U16)-40)
(Unit = dBm) <Help> This Measure
gives the maximum receive power
value among the network lanes of
the Client Transceiver
"
::= { pm200frs02MesrclientRxPwrMaxEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineNetTxLaserOutputPwr articles
--- *********************************************************
pm200frs02MesrlineNetTxLaserOutputPwrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineNetTxLaserOutputPwrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineNetTxLaserOutputPwr
Article
"
::= { pm200frs02MesrLine 144 }
pm200frs02MesrlineNetTxLaserOutputPwrEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineNetTxLaserOutputPwrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineNetTxLaserOutputPwr
table
"
INDEX { pm200frs02MesrlineNetTxLaserOutputPwrIndex }
::= { pm200frs02MesrlineNetTxLaserOutputPwrTable 1 }
Pm200frs02MesrlineNetTxLaserOutputPwrEntry ::=
SEQUENCE {
pm200frs02MesrlineNetTxLaserOutputPwrIndex
INTEGER,
pm200frs02MesrlineNetTxLaserOutputPwrPortn
INTEGER
}
pm200frs02MesrlineNetTxLaserOutputPwrIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineNetTxLaserOutputPwr
table
"
::= { pm200frs02MesrlineNetTxLaserOutputPwrEntry 1 }
pm200frs02MesrlineNetTxLaserOutputPwrPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current Line Trscv Tx Power :This
OID gives the Tx Laser transmit
power value of the Line Transceiver,
read in the DDM (Digital Diagnostic
Monitoring) (Power = AV_S16/100)
(Unit = dBm) <Help> This Measure
gives the Tx Laser transmit power
value of the Line Transceiver
"
::= { pm200frs02MesrlineNetTxLaserOutputPwrEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineNetTxLaserTemp articles
--- *********************************************************
pm200frs02MesrlineNetTxLaserTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineNetTxLaserTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineNetTxLaserTemp
Article
"
::= { pm200frs02MesrLine 148 }
pm200frs02MesrlineNetTxLaserTempEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineNetTxLaserTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineNetTxLaserTemp
table
"
INDEX { pm200frs02MesrlineNetTxLaserTempIndex }
::= { pm200frs02MesrlineNetTxLaserTempTable 1 }
Pm200frs02MesrlineNetTxLaserTempEntry ::=
SEQUENCE {
pm200frs02MesrlineNetTxLaserTempIndex
INTEGER,
pm200frs02MesrlineNetTxLaserTempPortn
INTEGER
}
pm200frs02MesrlineNetTxLaserTempIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineNetTxLaserTemp
table
"
::= { pm200frs02MesrlineNetTxLaserTempEntry 1 }
pm200frs02MesrlineNetTxLaserTempPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current Line Trscv Tx Laser Temperature
:This OID gives the Tx Laser Temperature
value of the Line Transceiver,
read from the DDM (Digital Diagnostic
Monitoring) (Temperature = AV_S16/256)
(Unit = C) <Help> This Measure
gives the Tx Laser Temperature
value of the Line Transceiver
"
::= { pm200frs02MesrlineNetTxLaserTempEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineNetTxBiasCurrent articles
--- *********************************************************
pm200frs02MesrlineNetTxBiasCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineNetTxBiasCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineNetTxBiasCurrent
Article
"
::= { pm200frs02MesrLine 152 }
pm200frs02MesrlineNetTxBiasCurrentEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineNetTxBiasCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineNetTxBiasCurrent
table
"
INDEX { pm200frs02MesrlineNetTxBiasCurrentIndex }
::= { pm200frs02MesrlineNetTxBiasCurrentTable 1 }
Pm200frs02MesrlineNetTxBiasCurrentEntry ::=
SEQUENCE {
pm200frs02MesrlineNetTxBiasCurrentIndex
INTEGER,
pm200frs02MesrlineNetTxBiasCurrentPortn
INTEGER
}
pm200frs02MesrlineNetTxBiasCurrentIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineNetTxBiasCurrent
table
"
::= { pm200frs02MesrlineNetTxBiasCurrentEntry 1 }
pm200frs02MesrlineNetTxBiasCurrentPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current Line Trscv Tx Laser Bias
:This OID gives the Tx Laser Bias
value of the Line Transceiver,
read from the DDM (Digital Diagnostic
Monitoring) (Bias = AV_S16/10)
(Unit = mA) <Help> This Measure
gives the Tx Laser Bias value of
the Line Transceiver
"
::= { pm200frs02MesrlineNetTxBiasCurrentEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineNetRxInputPwr articles
--- *********************************************************
pm200frs02MesrlineNetRxInputPwrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineNetRxInputPwrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineNetRxInputPwr
Article
"
::= { pm200frs02MesrLine 156 }
pm200frs02MesrlineNetRxInputPwrEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineNetRxInputPwrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineNetRxInputPwr
table
"
INDEX { pm200frs02MesrlineNetRxInputPwrIndex }
::= { pm200frs02MesrlineNetRxInputPwrTable 1 }
Pm200frs02MesrlineNetRxInputPwrEntry ::=
SEQUENCE {
pm200frs02MesrlineNetRxInputPwrIndex
INTEGER,
pm200frs02MesrlineNetRxInputPwrPortn
INTEGER
}
pm200frs02MesrlineNetRxInputPwrIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineNetRxInputPwr
table
"
::= { pm200frs02MesrlineNetRxInputPwrEntry 1 }
pm200frs02MesrlineNetRxInputPwrPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current Line Trscv Rx Power :This
OID gives the Receive power value
of the Line Transceiver, read in
the DDM (Digital Diagnostic Monitoring)
(Power = AV_S16/100) (Unit = dBm)
<Help> This Measure gives the Receive
power value of the Line Transceiver
"
::= { pm200frs02MesrlineNetRxInputPwrEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineResidualChromaticDisp articles
--- *********************************************************
pm200frs02MesrlineResidualChromaticDispTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineResidualChromaticDispEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineResidualChromaticDisp
Article
"
::= { pm200frs02MesrLine 160 }
pm200frs02MesrlineResidualChromaticDispEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineResidualChromaticDispEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineResidualChromaticDisp
table
"
INDEX { pm200frs02MesrlineResidualChromaticDispIndex }
::= { pm200frs02MesrlineResidualChromaticDispTable 1 }
Pm200frs02MesrlineResidualChromaticDispEntry ::=
SEQUENCE {
pm200frs02MesrlineResidualChromaticDispIndex
INTEGER,
pm200frs02MesrlineResidualChromaticDispPortn
INTEGER
}
pm200frs02MesrlineResidualChromaticDispIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineResidualChromaticDisp
table
"
::= { pm200frs02MesrlineResidualChromaticDispEntry 1 }
pm200frs02MesrlineResidualChromaticDispPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current Residual Chromatic Dispersion
:This OID gives the current Residual
Chromatic Dispersion on the Line
interface (Dispersion = AV_S16*(-2))
(Unit = ps/nm)<Help> This measure
gives the current Residual Chromatic
Dispersion on the Line interface.
"
::= { pm200frs02MesrlineResidualChromaticDispEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineDiffGroupDelay articles
--- *********************************************************
pm200frs02MesrlineDiffGroupDelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineDiffGroupDelayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineDiffGroupDelay
Article
"
::= { pm200frs02MesrLine 164 }
pm200frs02MesrlineDiffGroupDelayEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineDiffGroupDelayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineDiffGroupDelay
table
"
INDEX { pm200frs02MesrlineDiffGroupDelayIndex }
::= { pm200frs02MesrlineDiffGroupDelayTable 1 }
Pm200frs02MesrlineDiffGroupDelayEntry ::=
SEQUENCE {
pm200frs02MesrlineDiffGroupDelayIndex
INTEGER,
pm200frs02MesrlineDiffGroupDelayPortn
INTEGER
}
pm200frs02MesrlineDiffGroupDelayIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineDiffGroupDelay
table
"
::= { pm200frs02MesrlineDiffGroupDelayEntry 1 }
pm200frs02MesrlineDiffGroupDelayPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current Differential Group Delay
:This OID gives the current Differential
Group Delay on the Line interface
(Delay = AV_S16) (Unit = ps)<Help>
This measure gives the current
Differential Group Delay on the
Line interface.
"
::= { pm200frs02MesrlineDiffGroupDelayEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineQFactor articles
--- *********************************************************
pm200frs02MesrlineQFactorTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineQFactorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineQFactor
Article
"
::= { pm200frs02MesrLine 168 }
pm200frs02MesrlineQFactorEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineQFactorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineQFactor
table
"
INDEX { pm200frs02MesrlineQFactorIndex }
::= { pm200frs02MesrlineQFactorTable 1 }
Pm200frs02MesrlineQFactorEntry ::=
SEQUENCE {
pm200frs02MesrlineQFactorIndex
INTEGER,
pm200frs02MesrlineQFactorPortn
INTEGER
}
pm200frs02MesrlineQFactorIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineQFactor
table
"
::= { pm200frs02MesrlineQFactorEntry 1 }
pm200frs02MesrlineQFactorPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current Q Factor :This OID gives
the current Q Factor on the Line
interface (Q Factor = AV_U16)
(Unit = dB) <Help> This measure
gives the current Q Factor on the
Line interface.
"
::= { pm200frs02MesrlineQFactorEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineCarrierFreqOffset articles
--- *********************************************************
pm200frs02MesrlineCarrierFreqOffsetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineCarrierFreqOffsetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineCarrierFreqOffset
Article
"
::= { pm200frs02MesrLine 172 }
pm200frs02MesrlineCarrierFreqOffsetEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineCarrierFreqOffsetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineCarrierFreqOffset
table
"
INDEX { pm200frs02MesrlineCarrierFreqOffsetIndex }
::= { pm200frs02MesrlineCarrierFreqOffsetTable 1 }
Pm200frs02MesrlineCarrierFreqOffsetEntry ::=
SEQUENCE {
pm200frs02MesrlineCarrierFreqOffsetIndex
INTEGER,
pm200frs02MesrlineCarrierFreqOffsetPortn
INTEGER
}
pm200frs02MesrlineCarrierFreqOffsetIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineCarrierFreqOffset
table
"
::= { pm200frs02MesrlineCarrierFreqOffsetEntry 1 }
pm200frs02MesrlineCarrierFreqOffsetPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current Carrier Frequency Offset
:This OID gives the current Carrier
Frequency Offset on the Line interface
(Offset = AV_S16) (Unit = MHz)<Help>
This measure gives the current
Carrier Frequency Offset on the
Line interface.
"
::= { pm200frs02MesrlineCarrierFreqOffsetEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrlineOsnr articles
--- *********************************************************
pm200frs02MesrlineOsnrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrlineOsnrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrlineOsnr
Article
"
::= { pm200frs02MesrLine 176 }
pm200frs02MesrlineOsnrEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrlineOsnrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrlineOsnr
table
"
INDEX { pm200frs02MesrlineOsnrIndex }
::= { pm200frs02MesrlineOsnrTable 1 }
Pm200frs02MesrlineOsnrEntry ::=
SEQUENCE {
pm200frs02MesrlineOsnrIndex
INTEGER,
pm200frs02MesrlineOsnrPortn
INTEGER
}
pm200frs02MesrlineOsnrIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrlineOsnr
table
"
::= { pm200frs02MesrlineOsnrEntry 1 }
pm200frs02MesrlineOsnrPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current OSNR :This OID gives the
current OSNR on the Line interface
(OSNR = AV_S16/10) (Unit = dB)<Help>
This measure gives the current
OSNR on the Line interface.
"
::= { pm200frs02MesrlineOsnrEntry 2 }
--- *****************************************************
--- LEAF for the lineNetTxLaserOutputPwrAverage article
--- *****************************************************
pm200frs02MesrlineNetTxLaserOutputPwrAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average Line Trscv Tx Power :This
OID gives the average Tx Laser
transmit power value among the
network lanes of the Line Transceiver,
read in the DDM (Digital Diagnostic
Monitoring) (Power = AV_S16/100)
(Unit = dBm) <Help> This Measure
gives the average Tx Laser transmit
power value among the network lanes
of the Line Transceiver
"
::= { pm200frs02MesrOther 196 }
--- *****************************************************
--- LEAF for the lineNetTxLaserTempAverage article
--- *****************************************************
pm200frs02MesrlineNetTxLaserTempAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average Line Trscv Tx Laser Temperature
:This OID gives the average Tx
Laser Temperature value among
the network lanes of the Line
Transceiver, read from the DDM
(Digital Diagnostic Monitoring)
(Temperature = AV_S16/256) (Unit
= C) <Help> This Measure gives
the average Tx Laser Temperature
value among the network lanes of
the Line Transceiver
"
::= { pm200frs02MesrOther 197 }
--- *****************************************************
--- LEAF for the lineNetTxBiasCurrentAverage article
--- *****************************************************
pm200frs02MesrlineNetTxBiasCurrentAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average Line Trscv Tx Laser Bias
:This OID gives the average Tx
Laser Bias value among the network
lanes of the Line Transceiver,
read from the DDM (Digital Diagnostic
Monitoring) (Bias = AV_S16/10)
(Unit = mA) <Help> This Measure
gives the average Tx Laser Bias
value among the network lanes of
the Line Transceiver
"
::= { pm200frs02MesrOther 198 }
--- *****************************************************
--- LEAF for the lineNetRxInputPwrAverage article
--- *****************************************************
pm200frs02MesrlineNetRxInputPwrAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average Line Trscv Rx Power :This
OID gives the average Receive power
value among the network lanes of
the Line Transceiver, read in the
DDM (Digital Diagnostic Monitoring)
(Power = AV_S16/100) (Unit = dBm)
<Help> This Measure gives the average
Receive power value among the network
lanes of the Line Transceiver
"
::= { pm200frs02MesrOther 199 }
--- *****************************************************
--- LEAF for the lineResidualChromaticDispAverage article
--- *****************************************************
pm200frs02MesrlineResidualChromaticDispAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average Residual Chromatic Dispersion
:This OID gives the average Residual
Chromatic Dispersion on the Line
interface since the last measure
reset (Dispersion = AV_S16*(-2))
(Unit = ps/nm)<Help> This measure
gives the average Residual Chromatic
Dispersion on the Line interface
since the last measure reset.
"
::= { pm200frs02MesrOther 200 }
--- *****************************************************
--- LEAF for the lineDiffGroupDelayAverage article
--- *****************************************************
pm200frs02MesrlineDiffGroupDelayAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average Differential Group Delay
:This OID gives the average Group
Delay on the Line interface since
the last measure reset (Delay =
AV_S16) (Unit = ps)<Help> This
measure gives the average Differential
Group Delay on the Line interface
since the last measure reset.
"
::= { pm200frs02MesrOther 201 }
--- *****************************************************
--- LEAF for the lineQFactorAverage article
--- *****************************************************
pm200frs02MesrlineQFactorAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average Q Factor :This OID gives
the average Q Factor on the Line
interface since the last measure
reset (Q Factor = AV_U16) (Unit
= dB) <Help> This measure gives
the average Q Factor on the Line
interface since the last measure
reset.
"
::= { pm200frs02MesrOther 202 }
--- *****************************************************
--- LEAF for the lineCarrierFreqOffsetAverage article
--- *****************************************************
pm200frs02MesrlineCarrierFreqOffsetAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average Carrier Frequency Offset
:This OID gives the average Carrier
Frequency Offset on the Line interface
since the last measure reset (Offset
= AV_S16) (Unit = MHz)<Help> This
measure gives the average Carrier
Frequency Offset on the Line interface
since the last measure reset
"
::= { pm200frs02MesrOther 203 }
--- *****************************************************
--- LEAF for the lineOsnrAverage article
--- *****************************************************
pm200frs02MesrlineOsnrAverage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Average OSNR :This OID gives the
average OSNR on the Line interface
since the last measure reset (OSNR
= AV_S16/10) (Unit = dB)<Help>
This measure gives the average
OSNR on the Line interface since
the last measure reset.
"
::= { pm200frs02MesrOther 204 }
--- *****************************************************
--- LEAF for the lineNetTxLaserOutputPwrMin article
--- *****************************************************
pm200frs02MesrlineNetTxLaserOutputPwrMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Line Trscv Tx Power :This
OID gives the minimum Tx Laser
transmit power value among the
network lanes of the Line Transceiver,
read in the DDM (Digital Diagnostic
Monitoring) (Power = AV_S16/100)
(Unit = dBm) <Help> This Measure
gives the minimum Tx Laser transmit
power value among the network lanes
of the Line Transceiver
"
::= { pm200frs02MesrOther 212 }
--- *****************************************************
--- LEAF for the lineNetTxLaserTempMin article
--- *****************************************************
pm200frs02MesrlineNetTxLaserTempMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Line Trscv Tx Laser Temperature
:This OID gives the minimum Tx
Laser Temperature value among
the network lanes of the Line
Transceiver, read from the DDM
(Digital Diagnostic Monitoring)
(Temperature = AV_S16/256) (Unit
= C) <Help> This Measure gives
the minimum Tx Laser Temperature
value among the network lanes of
the Line Transceiver
"
::= { pm200frs02MesrOther 213 }
--- *****************************************************
--- LEAF for the lineNetTxBiasCurrentMin article
--- *****************************************************
pm200frs02MesrlineNetTxBiasCurrentMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Line Trscv Tx Laser Bias :This
OID gives the minimum Tx Laser
Bias value among the network lanes
of the Line Transceiver, read from
the DDM (Digital Diagnostic Monitoring)
(Bias = AV_S16/10) (Unit = mA)
<Help> This Measure gives the
minimum Tx Laser Bias value among
the network lanes of the Line Transceiver
"
::= { pm200frs02MesrOther 214 }
--- *****************************************************
--- LEAF for the lineNetRxInputPwrMin article
--- *****************************************************
pm200frs02MesrlineNetRxInputPwrMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Line Trscv Rx Power :This
OID gives the minimum Receive
power value among the network
lanes of the Line Transceiver,
read in the DDM (Digital Diagnostic
Monitoring) (Power = AV_S16/100)
(Unit = dBm) <Help> This Measure
gives the minimum Receive power
value among the network lanes of
the Line Transceiver
"
::= { pm200frs02MesrOther 215 }
--- *****************************************************
--- LEAF for the lineResidualChromaticDispMin article
--- *****************************************************
pm200frs02MesrlineResidualChromaticDispMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Residual Chromatic Dispersion
:This OID gives the minimum Residual
Chromatic Dispersion on the Line
interface since the last measure
reset (Dispersion = AV_S16*(-2))
(Unit = ps/nm)<Help> This measure
gives the minimum Residual Chromatic
Dispersion on the Line interface
since the last measure reset.
"
::= { pm200frs02MesrOther 216 }
--- *****************************************************
--- LEAF for the lineDiffGroupDelayMin article
--- *****************************************************
pm200frs02MesrlineDiffGroupDelayMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Differential Group Delay :This
OID gives the minimum Differential
Group Delay on the Line interface
since the last measure reset (Delay
= AV_S16) (Unit = ps)<Help> This
measure gives the minimum Differential
Group Delay on the Line interface
since the last measure reset.
"
::= { pm200frs02MesrOther 217 }
--- *****************************************************
--- LEAF for the lineQFactorMin article
--- *****************************************************
pm200frs02MesrlineQFactorMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Q Factor :This OID gives the
minimum Q Factor on the Line interface
since the last measure reset (Q
Factor = AV_U16) (Unit = dB)<Help>
This measure gives the minimum
Q Factor on the Line interface
since the last measure reset.
"
::= { pm200frs02MesrOther 218 }
--- *****************************************************
--- LEAF for the lineCarrierFreqOffsetMin article
--- *****************************************************
pm200frs02MesrlineCarrierFreqOffsetMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min Carrier Frequency Offset :This
OID gives the minimum Carrier Frequency
Offset on the Line interface since
the last measure reset (Offset
= AV_S16) (Unit = MHz)<Help>
This measure gives the minimum
Carrier Frequency Offset on the
Line interface since the last measure
reset
"
::= { pm200frs02MesrOther 219 }
--- *****************************************************
--- LEAF for the lineOsnrMin article
--- *****************************************************
pm200frs02MesrlineOsnrMin OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Min OSNR :This OID gives the minimum
OSNR on the Line interface since
the last measure reset (OSNR =
AV_S16/10) (Unit = dB)<Help> This
measure gives the minimum OSNR
on the Line interface since the
last measure reset.
"
::= { pm200frs02MesrOther 220 }
--- *****************************************************
--- LEAF for the lineNetTxLaserOutputPwrMax article
--- *****************************************************
pm200frs02MesrlineNetTxLaserOutputPwrMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Line Trscv Tx Power :This
OID gives the maximum Tx Laser
transmit power value among the
network lanes of the Line Transceiver,
read in the DDM (Digital Diagnostic
Monitoring) (Power = AV_S16/100)
(Unit = dBm) <Help> This Measure
gives the maximum Tx Laser transmit
power value among the network lanes
of the Line Transceiver
"
::= { pm200frs02MesrOther 228 }
--- *****************************************************
--- LEAF for the lineNetTxLaserTempMax article
--- *****************************************************
pm200frs02MesrlineNetTxLaserTempMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Line Trscv Tx Laser Temperature
:This OID gives the maximum Tx
Laser Temperature value among
the network lanes of the Line
Transceiver, read from the DDM
(Digital Diagnostic Monitoring)
(Temperature = AV_S16/256) (Unit
= C) <Help> This Measure gives
the maximum Tx Laser Temperature
value among the network lanes of
the Line Transceiver
"
::= { pm200frs02MesrOther 229 }
--- *****************************************************
--- LEAF for the lineNetTxBiasCurrentMax article
--- *****************************************************
pm200frs02MesrlineNetTxBiasCurrentMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Line Trscv Tx Laser Bias :This
OID gives the maximum Tx Laser
Bias value among the network lanes
of the Line Transceiver, read from
the DDM (Digital Diagnostic Monitoring)
(Bias = AV_S16/10) (Unit = mA)
<Help> This Measure gives the
maximum Tx Laser Bias value among
the network lanes of the Line Transceiver
"
::= { pm200frs02MesrOther 230 }
--- *****************************************************
--- LEAF for the lineNetRxInputPwrMax article
--- *****************************************************
pm200frs02MesrlineNetRxInputPwrMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Line Trscv Rx Power :This
OID gives the maximum Receive
power value among the network
lanes of the Line Transceiver,
read in the DDM (Digital Diagnostic
Monitoring) (Power = AV_S16/100)
(Unit = dBm) <Help> This Measure
gives the maximum Receive power
value among the network lanes of
the Line Transceiver
"
::= { pm200frs02MesrOther 231 }
--- *****************************************************
--- LEAF for the lineResidualChromaticDispMax article
--- *****************************************************
pm200frs02MesrlineResidualChromaticDispMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Residual Chromatic Dispersion
:This OID gives the maximum Residual
Chromatic Dispersion on the Line
interface since the last measure
reset (Dispersion = AV_S16*(-2))
(Unit = ps/nm)<Help> This measure
gives the maximum Residual Chromatic
Dispersion on the Line interface
since the last measure reset.
"
::= { pm200frs02MesrOther 232 }
--- *****************************************************
--- LEAF for the lineDiffGroupDelayMax article
--- *****************************************************
pm200frs02MesrlineDiffGroupDelayMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Differential Group Delay :This
OID gives the maximum Differential
Group Delay on the Line interface
since the last measure reset (Delay
= AV_S16) (Unit = ps)<Help> This
measure gives the maximum Differential
Group Delay on the Line interface
since the last measure reset.
"
::= { pm200frs02MesrOther 233 }
--- *****************************************************
--- LEAF for the lineQFactorMax article
--- *****************************************************
pm200frs02MesrlineQFactorMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Q Factor :This OID gives the
maximum Q Factor on the Line interface
since the last measure reset (Q
Factor = AV_U16) (Unit = dB)<Help>
This measure gives the maximum
Q Factor on the Line interface
since the last measure reset.
"
::= { pm200frs02MesrOther 234 }
--- *****************************************************
--- LEAF for the lineCarrierFreqOffsetMax article
--- *****************************************************
pm200frs02MesrlineCarrierFreqOffsetMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max Carrier Frequency Offset :This
OID gives the maximum Carrier Frequency
Offset on the Line interface since
the last measure reset (Offset
= AV_S16) (Unit = MHz)<Help>
This measure gives the maximum
Carrier Frequency Offset on the
Line interface since the last measure
reset.
"
::= { pm200frs02MesrOther 235 }
--- *****************************************************
--- LEAF for the lineOsnrMax article
--- *****************************************************
pm200frs02MesrlineOsnrMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Max OSNR :This OID gives the maximum
OSNR on the Line interface since
the last measure reset (OSNR
= AV_S16/10) (Unit = dB)<Help>
This measure gives the maximum
OSNR on the Line interface since
the last measure reset
"
::= { pm200frs02MesrOther 236 }
--- *****************************************************
--- LEAF for the regVoltage article
--- *****************************************************
pm200frs02MesrregVoltage OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Regulator Voltage :This OID gives
the voltage value of the Regulator
(Voltage = AV_U16) (Unit = mV)
<Help> This Measure gives the
Regulator Voltage
"
::= { pm200frs02MesrOther 249 }
--- *****************************************************
--- LEAF for the regCurrent article
--- *****************************************************
pm200frs02MesrregCurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Regulator Current :This OID gives
the current value of the Regulator
(Current = AV_U16/1000) (Unit =
A) <Help> This Measure gives the
Regulator Current
"
::= { pm200frs02MesrOther 250 }
--- *****************************************************
--- LEAF for the regTemp article
--- *****************************************************
pm200frs02MesrregTemp OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Regulator Temperature :This OID
gives the temperature value of
the Regulator (Temperature = AV_S16)
(Unit = C) <Help> This Measure
gives the Regulator Temperature
"
::= { pm200frs02MesrOther 251 }
--- *****************************************************
--- LEAF for the trscv1Temp article
--- *****************************************************
pm200frs02Mesrtrscv1Temp OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Temperature :This OID
gives the temperature value of
the Transceiver, read from the
DDM (Digital Diagnostic Monitoring)
(Temperature = AV_S16/256) (Unit
= C) <Help> This Measure gives
the temperature value of the Transceiver
"
::= { pm200frs02MesrOther 252 }
--- *****************************************************
--- LEAF for the trscv2Temp article
--- *****************************************************
pm200frs02Mesrtrscv2Temp OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Temperature :This OID
gives the temperature value of
the Transceiver, read from the
DDM (Digital Diagnostic Monitoring)
(Temperature = AV_S16/256) (Unit
= C) <Help> This Measure gives
the temperature value of the Transceiver
"
::= { pm200frs02MesrOther 253 }
--- *****************************************************
--- LEAF for the trscv1PowerSupply article
--- *****************************************************
pm200frs02Mesrtrscv1PowerSupply OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q1 Trscv Voltage :This OID gives
the voltage value of the QSFP plugged
into the port, read from the DDM
(Digital Diagnostic Monitoring)
(Voltage = AV_U16/10000) (Unit
= V) <Help> This measure gives
the power supply voltage of the
client transceiver
"
::= { pm200frs02MesrOther 254 }
--- *****************************************************
--- LEAF for the trscv2PowerSupply article
--- *****************************************************
pm200frs02Mesrtrscv2PowerSupply OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Q2 Trscv Voltage :This OID gives
the voltage value of the QSFP plugged
into the port, read from the DDM
(Digital Diagnostic Monitoring)
(Voltage = AV_U16/10000) (Unit
= V) <Help> This measure gives
the power supply voltage of the
client transceiver
"
::= { pm200frs02MesrOther 255 }
--- *********************************************************
--- TABLE for the pm200frs02MesrclientTxCompositePwr articles
--- *********************************************************
pm200frs02MesrclientTxCompositePwrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrclientTxCompositePwrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrclientTxCompositePwr
Article
"
::= { pm200frs02MesrClient 256 }
pm200frs02MesrclientTxCompositePwrEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrclientTxCompositePwrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrclientTxCompositePwr
table
"
INDEX { pm200frs02MesrclientTxCompositePwrIndex }
::= { pm200frs02MesrclientTxCompositePwrTable 1 }
Pm200frs02MesrclientTxCompositePwrEntry ::=
SEQUENCE {
pm200frs02MesrclientTxCompositePwrIndex
INTEGER,
pm200frs02MesrclientTxCompositePwrPortn
INTEGER
}
pm200frs02MesrclientTxCompositePwrIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrclientTxCompositePwr
table
"
::= { pm200frs02MesrclientTxCompositePwrEntry 1 }
pm200frs02MesrclientTxCompositePwrPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Composite Tx Power (LR4/SR4)
:This OID gives the composite transmit
power (sum of the network lanes
transmit power) of the Client Transceiver,
read from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV_U16)-40)
(Unit = dBm) <Help> This Measure
gives the composite transmit power
(sum of the network lanes transmit
power) of the Client Transceiver
(LR4/SR4 only)
"
::= { pm200frs02MesrclientTxCompositePwrEntry 2 }
--- *********************************************************
--- TABLE for the pm200frs02MesrclientRxCompositePwr articles
--- *********************************************************
pm200frs02MesrclientRxCompositePwrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02MesrclientRxCompositePwrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02MesrclientRxCompositePwr
Article
"
::= { pm200frs02MesrClient 288 }
pm200frs02MesrclientRxCompositePwrEntry OBJECT-TYPE
SYNTAX Pm200frs02MesrclientRxCompositePwrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02MesrclientRxCompositePwr
table
"
INDEX { pm200frs02MesrclientRxCompositePwrIndex }
::= { pm200frs02MesrclientRxCompositePwrTable 1 }
Pm200frs02MesrclientRxCompositePwrEntry ::=
SEQUENCE {
pm200frs02MesrclientRxCompositePwrIndex
INTEGER,
pm200frs02MesrclientRxCompositePwrPortn
INTEGER
}
pm200frs02MesrclientRxCompositePwrIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02MesrclientRxCompositePwr
table
"
::= { pm200frs02MesrclientRxCompositePwrEntry 1 }
pm200frs02MesrclientRxCompositePwrPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Composite Rx Power (LR4/SR4)
:This OID gives the composite receive
power (sum of the network lanes
receive power) of the Client Transceiver,
read from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV_U16)-40)
(Unit = dBm) <Help> This Measure
gives the composite receive power
(sum of the network lanes receive
power) of the Client Transceiver
(LR4/SR4 only)
"
::= { pm200frs02MesrclientRxCompositePwrEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- PERFORMANCE
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- Leaf of the telecomInputClientCurrent15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomInputClientCurrent15Stat articles
--- *********************************************************
pm200frs02PerfTelecomInputClientCurrent15StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomInputClientCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomInputClientCurrent15Stat
Article
"
::= { pm200frs02MonPerfClient 16 }
pm200frs02PerfTelecomInputClientCurrent15StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomInputClientCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomInputClientCurrent15Stat
table
"
INDEX { pm200frs02PerfTelecomInputClientCurrent15StatIndex }
::= { pm200frs02PerfTelecomInputClientCurrent15StatTable 1 }
Pm200frs02PerfTelecomInputClientCurrent15StatEntry ::=
SEQUENCE {
pm200frs02PerfTelecomInputClientCurrent15StatIndex
INTEGER,
pm200frs02PerfTelecomInputClientCurrent15StatInvCvPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent15StatCvValuePortn
Unsigned32,
pm200frs02PerfTelecomInputClientCurrent15StatInvEsPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent15StatEsValuePortn
Unsigned32,
pm200frs02PerfTelecomInputClientCurrent15StatInvSesPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent15StatSesValuePortn
Unsigned32,
pm200frs02PerfTelecomInputClientCurrent15StatInvSefsPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent15StatSefsValuePortn
Unsigned32,
pm200frs02PerfTelecomInputClientCurrent15StatInvUasPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent15StatUasValuePortn
Unsigned32
}
pm200frs02PerfTelecomInputClientCurrent15StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomInputClientCurrent15Stat
table
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 1 }
pm200frs02PerfTelecomInputClientCurrent15StatInvCvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min EBC counter inv.
:This OID indicates that the current
15-min Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 2 }
pm200frs02PerfTelecomInputClientCurrent15StatCvValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min EBC counter :This
OID gives the current 15-min Coding
Violation counter value
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 3 }
pm200frs02PerfTelecomInputClientCurrent15StatInvEsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min ES counter inv.
:This OID indicates that the current
15-min Errored Second counter is
invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 4 }
pm200frs02PerfTelecomInputClientCurrent15StatEsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min ES counter :This
OID gives the current 15-min Errored
Second counter value
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 5 }
pm200frs02PerfTelecomInputClientCurrent15StatInvSesPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SES counter inv.
:This OID indicates that the current
15-min severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 6 }
pm200frs02PerfTelecomInputClientCurrent15StatSesValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SES counter :This
OID gives the current 15-min severely
Errored Second counter value
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 7 }
pm200frs02PerfTelecomInputClientCurrent15StatInvSefsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SEFS counter inv.
:This OID indicates that the current
15-min severely Errored Framing
Second counter is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 8 }
pm200frs02PerfTelecomInputClientCurrent15StatSefsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SEFS counter :This
OID gives the current 15-min severely
Errored Framing Second counter
value
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 9 }
pm200frs02PerfTelecomInputClientCurrent15StatInvUasPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min UAS counter inv.
:This OID indicates that the current
15-min UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 10 }
pm200frs02PerfTelecomInputClientCurrent15StatUasValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min UAS counter :This
OID gives the current 15-min UnAvailable
Second counter value
"
::= { pm200frs02PerfTelecomInputClientCurrent15StatEntry 11 }
--- *****************************************************
--- Leaf of the telecomInputClientPast15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomInputClientPast15StatHistory articles
--- *********************************************************
pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomInputClientPast15StatHistory
Article
"
::= { pm200frs02MonPerfClient 48 }
pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomInputClientPast15StatHistory
table
"
INDEX { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Index }
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Table 1 }
Pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Index
INTEGER,
pm200frs02PerfTelecomInputClientPast15StatHistoryInvCvPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast15StatHistoryCvValuePort1
Unsigned32,
pm200frs02PerfTelecomInputClientPast15StatHistoryInvEsPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast15StatHistoryEsValuePort1
Unsigned32,
pm200frs02PerfTelecomInputClientPast15StatHistoryInvSesPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast15StatHistorySesValuePort1
Unsigned32,
pm200frs02PerfTelecomInputClientPast15StatHistoryInvSefsPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast15StatHistorySefsValuePort1
Unsigned32,
pm200frs02PerfTelecomInputClientPast15StatHistoryInvUasPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast15StatHistoryUasValuePort1
Unsigned32
}
pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomInputClientPast15StatHistory
table
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 1 }
pm200frs02PerfTelecomInputClientPast15StatHistoryInvCvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min EBC counter inv.
:This OID indicates that the previous
15-min Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 2 }
pm200frs02PerfTelecomInputClientPast15StatHistoryCvValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min EBC counter :This
OID gives the previous 15-min Coding
Violation counter value
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 3 }
pm200frs02PerfTelecomInputClientPast15StatHistoryInvEsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min ES counter inv.
:This OID indicates that the previous
15-min Errored Second counter is
invalid
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 4 }
pm200frs02PerfTelecomInputClientPast15StatHistoryEsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min ES counter :This
OID gives the previous 15-min Errored
Second counter value
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 5 }
pm200frs02PerfTelecomInputClientPast15StatHistoryInvSesPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SES counter inv.
:This OID indicates that the previous
15-min severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 6 }
pm200frs02PerfTelecomInputClientPast15StatHistorySesValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SES counter :This
OID gives the previous 15-min severely
Errored Second counter value
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 7 }
pm200frs02PerfTelecomInputClientPast15StatHistoryInvSefsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SEFS counter inv.
:This OID indicates that the previous
15-min severely Errored Framing
Second counter is invalid
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 8 }
pm200frs02PerfTelecomInputClientPast15StatHistorySefsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SEFS counter :This
OID gives the previous 15-min severely
Errored Framing Second counter
value
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 9 }
pm200frs02PerfTelecomInputClientPast15StatHistoryInvUasPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min UAS counter inv.
:This OID indicates that the previous
15-min UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 10 }
pm200frs02PerfTelecomInputClientPast15StatHistoryUasValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min UAS counter :This
OID gives the previous 15-min UnAvailable
Second counter value
"
::= { pm200frs02PerfTelecomInputClientPast15StatHistoryPort1Entry 11 }
--- *****************************************************
--- Leaf of the telecomInputClientCurrent24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomInputClientCurrent24Stat articles
--- *********************************************************
pm200frs02PerfTelecomInputClientCurrent24StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomInputClientCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomInputClientCurrent24Stat
Article
"
::= { pm200frs02MonPerfClient 80 }
pm200frs02PerfTelecomInputClientCurrent24StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomInputClientCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomInputClientCurrent24Stat
table
"
INDEX { pm200frs02PerfTelecomInputClientCurrent24StatIndex }
::= { pm200frs02PerfTelecomInputClientCurrent24StatTable 1 }
Pm200frs02PerfTelecomInputClientCurrent24StatEntry ::=
SEQUENCE {
pm200frs02PerfTelecomInputClientCurrent24StatIndex
INTEGER,
pm200frs02PerfTelecomInputClientCurrent24StatInvCvPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent24StatCvValuePortn
Unsigned32,
pm200frs02PerfTelecomInputClientCurrent24StatInvEsPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent24StatEsValuePortn
Unsigned32,
pm200frs02PerfTelecomInputClientCurrent24StatInvSesPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent24StatSesValuePortn
Unsigned32,
pm200frs02PerfTelecomInputClientCurrent24StatInvSefsPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent24StatSefsValuePortn
Unsigned32,
pm200frs02PerfTelecomInputClientCurrent24StatInvUasPortn
EkiOnOff,
pm200frs02PerfTelecomInputClientCurrent24StatUasValuePortn
Unsigned32
}
pm200frs02PerfTelecomInputClientCurrent24StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomInputClientCurrent24Stat
table
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 1 }
pm200frs02PerfTelecomInputClientCurrent24StatInvCvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours EBC counter inv.
:This OID indicates that the current
24-hours Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 2 }
pm200frs02PerfTelecomInputClientCurrent24StatCvValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours EBC counter :This
OID gives the current 24-hours
Coding Violation counter value
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 3 }
pm200frs02PerfTelecomInputClientCurrent24StatInvEsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours ES counter inv.
:This OID indicates that the current
24-hours Errored Second counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 4 }
pm200frs02PerfTelecomInputClientCurrent24StatEsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours ES counter :This
OID gives the current 24-hours
Errored Second counter value
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 5 }
pm200frs02PerfTelecomInputClientCurrent24StatInvSesPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SES counter inv.
:This OID indicates that the current
24-hours severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 6 }
pm200frs02PerfTelecomInputClientCurrent24StatSesValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SES counter :This
OID gives the current 24-hours
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 7 }
pm200frs02PerfTelecomInputClientCurrent24StatInvSefsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SEFS counter
inv. :This OID indicates that
the current 24-hours severely
Errored Framing Second counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 8 }
pm200frs02PerfTelecomInputClientCurrent24StatSefsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SEFS counter
:This OID gives the current 24-hours
severely Errored Framing Second
counter value
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 9 }
pm200frs02PerfTelecomInputClientCurrent24StatInvUasPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours UAS counter inv.
:This OID indicates that the current
24-hours UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 10 }
pm200frs02PerfTelecomInputClientCurrent24StatUasValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours UAS counter :This
OID gives the current 24-hours
UnAvailable Second counter value
"
::= { pm200frs02PerfTelecomInputClientCurrent24StatEntry 11 }
--- *****************************************************
--- Leaf of the telecomInputClientPast24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomInputClientPast24StatHistory articles
--- *********************************************************
pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomInputClientPast24StatHistory
Article
"
::= { pm200frs02MonPerfClient 112 }
pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomInputClientPast24StatHistory
table
"
INDEX { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Index }
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Table 1 }
Pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Index
INTEGER,
pm200frs02PerfTelecomInputClientPast24StatHistoryInvCvPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast24StatHistoryCvValuePort1
Unsigned32,
pm200frs02PerfTelecomInputClientPast24StatHistoryInvEsPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast24StatHistoryEsValuePort1
Unsigned32,
pm200frs02PerfTelecomInputClientPast24StatHistoryInvSesPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast24StatHistorySesValuePort1
Unsigned32,
pm200frs02PerfTelecomInputClientPast24StatHistoryInvSefsPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast24StatHistorySefsValuePort1
Unsigned32,
pm200frs02PerfTelecomInputClientPast24StatHistoryInvUasPort1
EkiOnOff,
pm200frs02PerfTelecomInputClientPast24StatHistoryUasValuePort1
Unsigned32
}
pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomInputClientPast24StatHistory
table
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 1 }
pm200frs02PerfTelecomInputClientPast24StatHistoryInvCvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours EBC counter
inv. :This OID indicates that
the previous 24-hours Coding Violation
counter is invalid
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 2 }
pm200frs02PerfTelecomInputClientPast24StatHistoryCvValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours EBC counter
:This OID gives the previous 24-hours
Coding Violation counter value
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 3 }
pm200frs02PerfTelecomInputClientPast24StatHistoryInvEsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours ES counter inv.
:This OID indicates that the previous
24-hours Errored Second counter
is invalid
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 4 }
pm200frs02PerfTelecomInputClientPast24StatHistoryEsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours ES counter :This
OID gives the previous 24-hours
Errored Second counter value
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 5 }
pm200frs02PerfTelecomInputClientPast24StatHistoryInvSesPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SES counter
inv. :This OID indicates that
the previous 24-hours severely
Errored Second counter is invalid
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 6 }
pm200frs02PerfTelecomInputClientPast24StatHistorySesValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SES counter
:This OID gives the previous 24-hours
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 7 }
pm200frs02PerfTelecomInputClientPast24StatHistoryInvSefsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SEFS counter
inv. :This OID indicates that the
previous 24-hours severely Errored
Framing Second counter is invalid
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 8 }
pm200frs02PerfTelecomInputClientPast24StatHistorySefsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SEFS counter
:This OID gives the previous 24-hours
severely Errored Framing Second
counter value
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 9 }
pm200frs02PerfTelecomInputClientPast24StatHistoryInvUasPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours UAS counter
inv. :This OID indicates that
the previous 24-hours UnAvailable
Second counter is invalid
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 10 }
pm200frs02PerfTelecomInputClientPast24StatHistoryUasValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours UAS counter
:This OID gives the previous 24-hours
UnAvailable Second counter value
"
::= { pm200frs02PerfTelecomInputClientPast24StatHistoryPort1Entry 11 }
--- *****************************************************
--- Leaf of the telecomOutputClientCurrent15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomOutputClientCurrent15Stat articles
--- *********************************************************
pm200frs02PerfTelecomOutputClientCurrent15StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomOutputClientCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomOutputClientCurrent15Stat
Article
"
::= { pm200frs02MonPerfClient 144 }
pm200frs02PerfTelecomOutputClientCurrent15StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomOutputClientCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomOutputClientCurrent15Stat
table
"
INDEX { pm200frs02PerfTelecomOutputClientCurrent15StatIndex }
::= { pm200frs02PerfTelecomOutputClientCurrent15StatTable 1 }
Pm200frs02PerfTelecomOutputClientCurrent15StatEntry ::=
SEQUENCE {
pm200frs02PerfTelecomOutputClientCurrent15StatIndex
INTEGER,
pm200frs02PerfTelecomOutputClientCurrent15StatInvCvPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent15StatCvValuePortn
Unsigned32,
pm200frs02PerfTelecomOutputClientCurrent15StatInvEsPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent15StatEsValuePortn
Unsigned32,
pm200frs02PerfTelecomOutputClientCurrent15StatInvSesPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent15StatSesValuePortn
Unsigned32,
pm200frs02PerfTelecomOutputClientCurrent15StatInvSefsPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent15StatSefsValuePortn
Unsigned32,
pm200frs02PerfTelecomOutputClientCurrent15StatInvUasPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent15StatUasValuePortn
Unsigned32
}
pm200frs02PerfTelecomOutputClientCurrent15StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomOutputClientCurrent15Stat
table
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 1 }
pm200frs02PerfTelecomOutputClientCurrent15StatInvCvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min EBC counter inv.
:This OID indicates that the current
15-min Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 2 }
pm200frs02PerfTelecomOutputClientCurrent15StatCvValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min EBC counter :This
OID gives the current 15-min Coding
Violation counter value
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 3 }
pm200frs02PerfTelecomOutputClientCurrent15StatInvEsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min ES counter inv.
:This OID indicates that the current
15-min Errored Second counter is
invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 4 }
pm200frs02PerfTelecomOutputClientCurrent15StatEsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min ES counter :This
OID gives the current 15-min Errored
Second counter value
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 5 }
pm200frs02PerfTelecomOutputClientCurrent15StatInvSesPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SES counter inv.
:This OID indicates that the current
15-min severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 6 }
pm200frs02PerfTelecomOutputClientCurrent15StatSesValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SES counter :This
OID gives the current 15-min severely
Errored Second counter value
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 7 }
pm200frs02PerfTelecomOutputClientCurrent15StatInvSefsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SEFS counter inv.
:This OID indicates that the current
15-min severely Errored Framing
Second counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 8 }
pm200frs02PerfTelecomOutputClientCurrent15StatSefsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SEFS counter :This
OID gives the current 15-min severely
Errored Framing Second counter
value
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 9 }
pm200frs02PerfTelecomOutputClientCurrent15StatInvUasPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min UAS counter inv.
:This OID indicates that the current
15-min UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 10 }
pm200frs02PerfTelecomOutputClientCurrent15StatUasValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min UAS counter :This
OID gives the current 15-min UnAvailable
Second counter value
"
::= { pm200frs02PerfTelecomOutputClientCurrent15StatEntry 11 }
--- *****************************************************
--- Leaf of the telecomOutputClientPast15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomOutputClientPast15StatHistory articles
--- *********************************************************
pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomOutputClientPast15StatHistory
Article
"
::= { pm200frs02MonPerfClient 176 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomOutputClientPast15StatHistory
table
"
INDEX { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Index }
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Table 1 }
Pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Index
INTEGER,
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvCvPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast15StatHistoryCvValuePort1
Unsigned32,
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvEsPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast15StatHistoryEsValuePort1
Unsigned32,
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvSesPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast15StatHistorySesValuePort1
Unsigned32,
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvSefsPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast15StatHistorySefsValuePort1
Unsigned32,
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvUasPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast15StatHistoryUasValuePort1
Unsigned32
}
pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomOutputClientPast15StatHistory
table
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 1 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvCvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min EBC counter inv.
:This OID indicates that the previous
15-min Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 2 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryCvValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min EBC counter :This
OID gives the previous 15-min Coding
Violation counter value
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 3 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvEsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min ES counter inv.
:This OID indicates that the previous
15-min Errored Second counter is
invalid
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 4 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryEsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min ES counter :This
OID gives the previous 15-min Errored
Second counter value
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 5 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvSesPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SES counter inv.
:This OID indicates that the previous
15-min severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 6 }
pm200frs02PerfTelecomOutputClientPast15StatHistorySesValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SES counter :This
OID gives the previous 15-min severely
Errored Second counter value
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 7 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvSefsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SEFS counter inv.
:This OID indicates that the previous
15-min severely Errored Framing
Second counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 8 }
pm200frs02PerfTelecomOutputClientPast15StatHistorySefsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SEFS counter :This
OID gives the previous 15-min severely
Errored Framing Second counter
value
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 9 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryInvUasPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min UAS counter inv.
:This OID indicates that the previous
15-min UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 10 }
pm200frs02PerfTelecomOutputClientPast15StatHistoryUasValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min UAS counter :This
OID gives the previous 15-min UnAvailable
Second counter value
"
::= { pm200frs02PerfTelecomOutputClientPast15StatHistoryPort1Entry 11 }
--- *****************************************************
--- Leaf of the telecomOutputClientCurrent24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomOutputClientCurrent24Stat articles
--- *********************************************************
pm200frs02PerfTelecomOutputClientCurrent24StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomOutputClientCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomOutputClientCurrent24Stat
Article
"
::= { pm200frs02MonPerfClient 208 }
pm200frs02PerfTelecomOutputClientCurrent24StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomOutputClientCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomOutputClientCurrent24Stat
table
"
INDEX { pm200frs02PerfTelecomOutputClientCurrent24StatIndex }
::= { pm200frs02PerfTelecomOutputClientCurrent24StatTable 1 }
Pm200frs02PerfTelecomOutputClientCurrent24StatEntry ::=
SEQUENCE {
pm200frs02PerfTelecomOutputClientCurrent24StatIndex
INTEGER,
pm200frs02PerfTelecomOutputClientCurrent24StatInvCvPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent24StatCvValuePortn
Unsigned32,
pm200frs02PerfTelecomOutputClientCurrent24StatInvEsPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent24StatEsValuePortn
Unsigned32,
pm200frs02PerfTelecomOutputClientCurrent24StatInvSesPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent24StatSesValuePortn
Unsigned32,
pm200frs02PerfTelecomOutputClientCurrent24StatInvSefsPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent24StatSefsValuePortn
Unsigned32,
pm200frs02PerfTelecomOutputClientCurrent24StatInvUasPortn
EkiOnOff,
pm200frs02PerfTelecomOutputClientCurrent24StatUasValuePortn
Unsigned32
}
pm200frs02PerfTelecomOutputClientCurrent24StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomOutputClientCurrent24Stat
table
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 1 }
pm200frs02PerfTelecomOutputClientCurrent24StatInvCvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours EBC counter inv.
:This OID indicates that the current
24-hours Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 2 }
pm200frs02PerfTelecomOutputClientCurrent24StatCvValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours EBC counter :This
OID gives the current 24-hours
Coding Violation counter value
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 3 }
pm200frs02PerfTelecomOutputClientCurrent24StatInvEsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours ES counter inv.
:This OID indicates that the current
24-hours Errored Second counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 4 }
pm200frs02PerfTelecomOutputClientCurrent24StatEsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours ES counter :This
OID gives the current 24-hours
Errored Second counter value
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 5 }
pm200frs02PerfTelecomOutputClientCurrent24StatInvSesPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SES counter inv.
:This OID indicates that the current
24-hours severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 6 }
pm200frs02PerfTelecomOutputClientCurrent24StatSesValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SES counter :This
OID gives the current 24-hours
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 7 }
pm200frs02PerfTelecomOutputClientCurrent24StatInvSefsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SEFS counter
inv. :This OID indicates that
the current 24-hours severely
Errored Framing Second counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 8 }
pm200frs02PerfTelecomOutputClientCurrent24StatSefsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SEFS counter
:This OID gives the current 24-hours
severely Errored Framing Second
counter value
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 9 }
pm200frs02PerfTelecomOutputClientCurrent24StatInvUasPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours UAS counter inv.
:This OID indicates that the current
24-hours UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 10 }
pm200frs02PerfTelecomOutputClientCurrent24StatUasValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours UAS counter :This
OID gives the current 24-hours
UnAvailable Second counter value
"
::= { pm200frs02PerfTelecomOutputClientCurrent24StatEntry 11 }
--- *****************************************************
--- Leaf of the telecomOutputClientPast24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomOutputClientPast24StatHistory articles
--- *********************************************************
pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomOutputClientPast24StatHistory
Article
"
::= { pm200frs02MonPerfClient 240 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomOutputClientPast24StatHistory
table
"
INDEX { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Index }
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Table 1 }
Pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Index
INTEGER,
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvCvPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast24StatHistoryCvValuePort1
Unsigned32,
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvEsPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast24StatHistoryEsValuePort1
Unsigned32,
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvSesPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast24StatHistorySesValuePort1
Unsigned32,
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvSefsPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast24StatHistorySefsValuePort1
Unsigned32,
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvUasPort1
EkiOnOff,
pm200frs02PerfTelecomOutputClientPast24StatHistoryUasValuePort1
Unsigned32
}
pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomOutputClientPast24StatHistory
table
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 1 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvCvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours EBC counter
inv. :This OID indicates that
the previous 24-hours Coding Violation
counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 2 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryCvValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours EBC counter
:This OID gives the previous 24-hours
Coding Violation counter value
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 3 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvEsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours ES counter inv.
:This OID indicates that the previous
24-hours Errored Second counter
is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 4 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryEsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours ES counter :This
OID gives the previous 24-hours
Errored Second counter value
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 5 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvSesPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SES counter
inv. :This OID indicates that
the previous 24-hours severely
Errored Second counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 6 }
pm200frs02PerfTelecomOutputClientPast24StatHistorySesValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SES counter
:This OID gives the previous 24-hours
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 7 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvSefsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SEFS counter
inv. :This OID indicates that the
previous 24-hours severely Errored
Framing Second counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 8 }
pm200frs02PerfTelecomOutputClientPast24StatHistorySefsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SEFS counter
:This OID gives the previous 24-hours
severely Errored Framing Second
counter value
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 9 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryInvUasPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours UAS counter
inv. :This OID indicates that
the previous 24-hours UnAvailable
Second counter is invalid
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 10 }
pm200frs02PerfTelecomOutputClientPast24StatHistoryUasValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours UAS counter
:This OID gives the previous 24-hours
UnAvailable Second counter value
"
::= { pm200frs02PerfTelecomOutputClientPast24StatHistoryPort1Entry 11 }
--- *****************************************************
--- Leaf of the telecomLinePostFecCurrent15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomLinePostFecCurrent15Stat articles
--- *********************************************************
pm200frs02PerfTelecomLinePostFecCurrent15StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomLinePostFecCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomLinePostFecCurrent15Stat
Article
"
::= { pm200frs02MonPerfLine 336 }
pm200frs02PerfTelecomLinePostFecCurrent15StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomLinePostFecCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomLinePostFecCurrent15Stat
table
"
INDEX { pm200frs02PerfTelecomLinePostFecCurrent15StatIndex }
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatTable 1 }
Pm200frs02PerfTelecomLinePostFecCurrent15StatEntry ::=
SEQUENCE {
pm200frs02PerfTelecomLinePostFecCurrent15StatIndex
INTEGER,
pm200frs02PerfTelecomLinePostFecCurrent15StatInvCvPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent15StatCvValuePortn
Unsigned32,
pm200frs02PerfTelecomLinePostFecCurrent15StatInvEsPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent15StatEsValuePortn
Unsigned32,
pm200frs02PerfTelecomLinePostFecCurrent15StatInvSesPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent15StatSesValuePortn
Unsigned32,
pm200frs02PerfTelecomLinePostFecCurrent15StatInvSefsPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent15StatSefsValuePortn
Unsigned32,
pm200frs02PerfTelecomLinePostFecCurrent15StatInvUasPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent15StatUasValuePortn
Unsigned32
}
pm200frs02PerfTelecomLinePostFecCurrent15StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomLinePostFecCurrent15Stat
table
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 1 }
pm200frs02PerfTelecomLinePostFecCurrent15StatInvCvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min EBC counter inv.
:This OID indicates that the current
15-min Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 2 }
pm200frs02PerfTelecomLinePostFecCurrent15StatCvValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min EBC counter :This
OID gives the current 15-min Coding
Violation counter value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 3 }
pm200frs02PerfTelecomLinePostFecCurrent15StatInvEsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min ES counter inv.
:This OID indicates that the current
15-min Errored Second counter is
invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 4 }
pm200frs02PerfTelecomLinePostFecCurrent15StatEsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min ES counter :This
OID gives the current 15-min Errored
Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 5 }
pm200frs02PerfTelecomLinePostFecCurrent15StatInvSesPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SES counter inv.
:This OID indicates that the current
15-min severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 6 }
pm200frs02PerfTelecomLinePostFecCurrent15StatSesValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SES counter :This
OID gives the current 15-min severely
Errored Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 7 }
pm200frs02PerfTelecomLinePostFecCurrent15StatInvSefsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SEFS counter inv.
:This OID indicates that the current
15-min severely Errored Framing
Second counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 8 }
pm200frs02PerfTelecomLinePostFecCurrent15StatSefsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min SEFS counter :This
OID gives the current 15-min severely
Errored Framing Second counter
value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 9 }
pm200frs02PerfTelecomLinePostFecCurrent15StatInvUasPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min UAS counter inv.
:This OID indicates that the current
15-min UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 10 }
pm200frs02PerfTelecomLinePostFecCurrent15StatUasValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min UAS counter :This
OID gives the current 15-min UnAvailable
Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent15StatEntry 11 }
--- *****************************************************
--- Leaf of the telecomLinePostFecPast15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomLinePostFecPast15StatHistory articles
--- *********************************************************
pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomLinePostFecPast15StatHistory
Article
"
::= { pm200frs02MonPerfLine 337 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomLinePostFecPast15StatHistory
table
"
INDEX { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Index }
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Table 1 }
Pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Index
INTEGER,
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvCvPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast15StatHistoryCvValuePort1
Unsigned32,
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvEsPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast15StatHistoryEsValuePort1
Unsigned32,
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvSesPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast15StatHistorySesValuePort1
Unsigned32,
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvSefsPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast15StatHistorySefsValuePort1
Unsigned32,
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvUasPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast15StatHistoryUasValuePort1
Unsigned32
}
pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomLinePostFecPast15StatHistory
table
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 1 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvCvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min EBC counter inv.
:This OID indicates that the previous
15-min Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 2 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryCvValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min EBC counter :This
OID gives the previous 15-min Coding
Violation counter value
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 3 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvEsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min ES counter inv.
:This OID indicates that the previous
15-min Errored Second counter is
invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 4 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryEsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min ES counter :This
OID gives the previous 15-min Errored
Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 5 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvSesPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SES counter inv.
:This OID indicates that the previous
15-min severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 6 }
pm200frs02PerfTelecomLinePostFecPast15StatHistorySesValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SES counter :This
OID gives the previous 15-min severely
Errored Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 7 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvSefsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SEFS counter inv.
:This OID indicates that the previous
15-min severely Errored Framing
Second counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 8 }
pm200frs02PerfTelecomLinePostFecPast15StatHistorySefsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min SEFS counter :This
OID gives the previous 15-min severely
Errored Framing Second counter
value
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 9 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryInvUasPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min UAS counter inv.
:This OID indicates that the previous
15-min UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 10 }
pm200frs02PerfTelecomLinePostFecPast15StatHistoryUasValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min UAS counter :This
OID gives the previous 15-min UnAvailable
Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecPast15StatHistoryPort1Entry 11 }
--- *****************************************************
--- Leaf of the telecomLinePostFecCurrent24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomLinePostFecCurrent24Stat articles
--- *********************************************************
pm200frs02PerfTelecomLinePostFecCurrent24StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomLinePostFecCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomLinePostFecCurrent24Stat
Article
"
::= { pm200frs02MonPerfLine 338 }
pm200frs02PerfTelecomLinePostFecCurrent24StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomLinePostFecCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomLinePostFecCurrent24Stat
table
"
INDEX { pm200frs02PerfTelecomLinePostFecCurrent24StatIndex }
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatTable 1 }
Pm200frs02PerfTelecomLinePostFecCurrent24StatEntry ::=
SEQUENCE {
pm200frs02PerfTelecomLinePostFecCurrent24StatIndex
INTEGER,
pm200frs02PerfTelecomLinePostFecCurrent24StatInvCvPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent24StatCvValuePortn
Unsigned32,
pm200frs02PerfTelecomLinePostFecCurrent24StatInvEsPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent24StatEsValuePortn
Unsigned32,
pm200frs02PerfTelecomLinePostFecCurrent24StatInvSesPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent24StatSesValuePortn
Unsigned32,
pm200frs02PerfTelecomLinePostFecCurrent24StatInvSefsPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent24StatSefsValuePortn
Unsigned32,
pm200frs02PerfTelecomLinePostFecCurrent24StatInvUasPortn
EkiOnOff,
pm200frs02PerfTelecomLinePostFecCurrent24StatUasValuePortn
Unsigned32
}
pm200frs02PerfTelecomLinePostFecCurrent24StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomLinePostFecCurrent24Stat
table
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 1 }
pm200frs02PerfTelecomLinePostFecCurrent24StatInvCvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours EBC counter inv.
:This OID indicates that the current
24-hours Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 2 }
pm200frs02PerfTelecomLinePostFecCurrent24StatCvValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours EBC counter :This
OID gives the current 24-hours
Coding Violation counter value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 3 }
pm200frs02PerfTelecomLinePostFecCurrent24StatInvEsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours ES counter inv.
:This OID indicates that the current
24-hours Errored Second counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 4 }
pm200frs02PerfTelecomLinePostFecCurrent24StatEsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours ES counter :This
OID gives the current 24-hours
Errored Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 5 }
pm200frs02PerfTelecomLinePostFecCurrent24StatInvSesPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SES counter inv.
:This OID indicates that the current
24-hours severely Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 6 }
pm200frs02PerfTelecomLinePostFecCurrent24StatSesValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SES counter :This
OID gives the current 24-hours
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 7 }
pm200frs02PerfTelecomLinePostFecCurrent24StatInvSefsPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SEFS counter
inv. :This OID indicates that
the current 24-hours severely
Errored Framing Second counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 8 }
pm200frs02PerfTelecomLinePostFecCurrent24StatSefsValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours SEFS counter
:This OID gives the current 24-hours
severely Errored Framing Second
counter value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 9 }
pm200frs02PerfTelecomLinePostFecCurrent24StatInvUasPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours UAS counter inv.
:This OID indicates that the current
24-hours UnAvailable Second counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 10 }
pm200frs02PerfTelecomLinePostFecCurrent24StatUasValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours UAS counter :This
OID gives the current 24-hours
UnAvailable Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecCurrent24StatEntry 11 }
--- *****************************************************
--- Leaf of the telecomLinePostFecPast24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomLinePostFecPast24StatHistory articles
--- *********************************************************
pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomLinePostFecPast24StatHistory
Article
"
::= { pm200frs02MonPerfLine 339 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomLinePostFecPast24StatHistory
table
"
INDEX { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Index }
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Table 1 }
Pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Index
INTEGER,
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvCvPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast24StatHistoryCvValuePort1
Unsigned32,
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvEsPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast24StatHistoryEsValuePort1
Unsigned32,
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvSesPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast24StatHistorySesValuePort1
Unsigned32,
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvSefsPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast24StatHistorySefsValuePort1
Unsigned32,
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvUasPort1
EkiOnOff,
pm200frs02PerfTelecomLinePostFecPast24StatHistoryUasValuePort1
Unsigned32
}
pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomLinePostFecPast24StatHistory
table
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 1 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvCvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours EBC counter
inv. :This OID indicates that
the previous 24-hours Coding Violation
counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 2 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryCvValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours EBC counter
:This OID gives the previous 24-hours
Coding Violation counter value
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 3 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvEsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours ES counter inv.
:This OID indicates that the previous
24-hours Errored Second counter
is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 4 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryEsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours ES counter :This
OID gives the previous 24-hours
Errored Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 5 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvSesPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SES counter
inv. :This OID indicates that
the previous 24-hours severely
Errored Second counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 6 }
pm200frs02PerfTelecomLinePostFecPast24StatHistorySesValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SES counter
:This OID gives the previous 24-hours
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 7 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvSefsPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SEFS counter
inv. :This OID indicates that the
previous 24-hours severely Errored
Framing Second counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 8 }
pm200frs02PerfTelecomLinePostFecPast24StatHistorySefsValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours SEFS counter
:This OID gives the previous 24-hours
severely Errored Framing Second
counter value
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 9 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryInvUasPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours UAS counter
inv. :This OID indicates that
the previous 24-hours UnAvailable
Second counter is invalid
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 10 }
pm200frs02PerfTelecomLinePostFecPast24StatHistoryUasValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours UAS counter
:This OID gives the previous 24-hours
UnAvailable Second counter value
"
::= { pm200frs02PerfTelecomLinePostFecPast24StatHistoryPort1Entry 11 }
--- *****************************************************
--- Leaf of the telecomBerLinePreFecCurrent15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomBerLinePreFecCurrent15Stat articles
--- *********************************************************
pm200frs02PerfTelecomBerLinePreFecCurrent15StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomBerLinePreFecCurrent15Stat
Article
"
::= { pm200frs02MonPerfLine 352 }
pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomBerLinePreFecCurrent15Stat
table
"
INDEX { pm200frs02PerfTelecomBerLinePreFecCurrent15StatIndex }
::= { pm200frs02PerfTelecomBerLinePreFecCurrent15StatTable 1 }
Pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry ::=
SEQUENCE {
pm200frs02PerfTelecomBerLinePreFecCurrent15StatIndex
INTEGER,
pm200frs02PerfTelecomBerLinePreFecCurrent15StatInvBerPortn
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecCurrent15StatBerValuePortn
Unsigned32,
pm200frs02PerfTelecomBerLinePreFecCurrent15StatInvMinBerPortn
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecCurrent15StatMinBerValuePortn
Unsigned32,
pm200frs02PerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortn
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortn
Unsigned32
}
pm200frs02PerfTelecomBerLinePreFecCurrent15StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomBerLinePreFecCurrent15Stat
table
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry 1 }
pm200frs02PerfTelecomBerLinePreFecCurrent15StatInvBerPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min BER counter inv.
:This OID indicates that the current
15-min Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry 2 }
pm200frs02PerfTelecomBerLinePreFecCurrent15StatBerValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min BER counter :This
OID gives the current 15-min Coding
Violation counter value
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry 3 }
pm200frs02PerfTelecomBerLinePreFecCurrent15StatInvMinBerPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min MinBER counter
inv. :This OID indicates that
the current 15-min Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry 4 }
pm200frs02PerfTelecomBerLinePreFecCurrent15StatMinBerValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min MinBER counter
:This OID gives the current 15-min
Errored Second counter value
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry 5 }
pm200frs02PerfTelecomBerLinePreFecCurrent15StatInvMaxBerPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min MaxBER counter
inv. :This OID indicates that
the current 15-min severely Errored
Second counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry 6 }
pm200frs02PerfTelecomBerLinePreFecCurrent15StatMaxBerValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 15-min MaxBER counter
:This OID gives the current 15-min
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent15StatEntry 7 }
--- *****************************************************
--- Leaf of the telecomBerLinePreFecPast15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomBerLinePreFecPast15StatHistory articles
--- *********************************************************
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomBerLinePreFecPast15StatHistory
Article
"
::= { pm200frs02MonPerfLine 353 }
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomBerLinePreFecPast15StatHistory
table
"
INDEX { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Index }
::= { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Table 1 }
Pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Index
INTEGER,
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1
Unsigned32,
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1
Unsigned32,
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1
Unsigned32
}
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomBerLinePreFecPast15StatHistory
table
"
::= { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry 1 }
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvBerPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min BER counter inv.
:This OID indicates that the previous
15-min Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry 2 }
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryBerValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min BER counter :This
OID gives the previous 15-min Coding
Violation counter value
"
::= { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry 3 }
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvMinBerPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min MinBER counter
inv. :This OID indicates that the
previous 15-min Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry 4 }
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryMinBerValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min MinBER counter
:This OID gives the previous 15-min
Errored Second counter value
"
::= { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry 5 }
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryInvMaxBerPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min MaxBER counter
inv. :This OID indicates that the
previous 15-min severely Errored
Second counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry 6 }
pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryMaxBerValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 15-min MaxBER counter
:This OID gives the previous 15-min
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomBerLinePreFecPast15StatHistoryPort1Entry 7 }
--- *****************************************************
--- Leaf of the telecomBerLinePreFecCurrent24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomBerLinePreFecCurrent24Stat articles
--- *********************************************************
pm200frs02PerfTelecomBerLinePreFecCurrent24StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomBerLinePreFecCurrent24Stat
Article
"
::= { pm200frs02MonPerfLine 354 }
pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomBerLinePreFecCurrent24Stat
table
"
INDEX { pm200frs02PerfTelecomBerLinePreFecCurrent24StatIndex }
::= { pm200frs02PerfTelecomBerLinePreFecCurrent24StatTable 1 }
Pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry ::=
SEQUENCE {
pm200frs02PerfTelecomBerLinePreFecCurrent24StatIndex
INTEGER,
pm200frs02PerfTelecomBerLinePreFecCurrent24StatInvBerPortn
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecCurrent24StatBerValuePortn
Unsigned32,
pm200frs02PerfTelecomBerLinePreFecCurrent24StatInvMinBerPortn
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecCurrent24StatMinBerValuePortn
Unsigned32,
pm200frs02PerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortn
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortn
Unsigned32
}
pm200frs02PerfTelecomBerLinePreFecCurrent24StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomBerLinePreFecCurrent24Stat
table
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry 1 }
pm200frs02PerfTelecomBerLinePreFecCurrent24StatInvBerPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours BER counter inv.
:This OID indicates that the current
24-hours Coding Violation counter
is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry 2 }
pm200frs02PerfTelecomBerLinePreFecCurrent24StatBerValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours BER counter :This
OID gives the current 24-hours
Coding Violation counter value
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry 3 }
pm200frs02PerfTelecomBerLinePreFecCurrent24StatInvMinBerPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hoursMinBER counter
inv. :This OID indicates that the
current 24-hours Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry 4 }
pm200frs02PerfTelecomBerLinePreFecCurrent24StatMinBerValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours MinBER counter
:This OID gives the current 24-hours
Errored Second counter value
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry 5 }
pm200frs02PerfTelecomBerLinePreFecCurrent24StatInvMaxBerPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours MaxBER counter
inv. :This OID indicates that the
current 24-hours severely Errored
Second counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry 6 }
pm200frs02PerfTelecomBerLinePreFecCurrent24StatMaxBerValuePortn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Current 24-hours MaxBER counter
:This OID gives the current 24-hours
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomBerLinePreFecCurrent24StatEntry 7 }
--- *****************************************************
--- Leaf of the telecomBerLinePreFecPast24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfTelecomBerLinePreFecPast24StatHistory articles
--- *********************************************************
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfTelecomBerLinePreFecPast24StatHistory
Article
"
::= { pm200frs02MonPerfLine 355 }
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfTelecomBerLinePreFecPast24StatHistory
table
"
INDEX { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Index }
::= { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Table 1 }
Pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Index
INTEGER,
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1
Unsigned32,
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1
Unsigned32,
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1
EkiOnOff,
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1
Unsigned32
}
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfTelecomBerLinePreFecPast24StatHistory
table
"
::= { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry 1 }
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvBerPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours BER counter
inv. :This OID indicates that
the previous 24-hours Coding Violation
counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry 2 }
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryBerValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours BER counter
:This OID gives the previous 24-hours
Coding Violation counter value
"
::= { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry 3 }
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvMinBerPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours MinBER counter
inv. :This OID indicates that the
previous 24-hours Errored Second
counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry 4 }
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryMinBerValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours MinBER counter
:This OID gives the previous 24-hours
Errored Second counter value
"
::= { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry 5 }
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryInvMaxBerPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours MaxBER counter
inv. :This OID indicates that the
previous 24-hours severely Errored
Second counter is invalid
"
::= { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry 6 }
pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryMaxBerValuePort1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Previous 24-hours MaxBER counter
:This OID gives the previous 24-hours
severely Errored Second counter
value
"
::= { pm200frs02PerfTelecomBerLinePreFecPast24StatHistoryPort1Entry 7 }
--- *****************************************************
--- Leaf of the datacomClientCurrent15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfDatacomClientCurrent15Stat articles
--- *********************************************************
pm200frs02PerfDatacomClientCurrent15StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfDatacomClientCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfDatacomClientCurrent15Stat
Article
"
::= { pm200frs02MonPerfClient 848 }
pm200frs02PerfDatacomClientCurrent15StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfDatacomClientCurrent15StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfDatacomClientCurrent15Stat
table
"
INDEX { pm200frs02PerfDatacomClientCurrent15StatIndex }
::= { pm200frs02PerfDatacomClientCurrent15StatTable 1 }
Pm200frs02PerfDatacomClientCurrent15StatEntry ::=
SEQUENCE {
pm200frs02PerfDatacomClientCurrent15StatIndex
INTEGER,
pm200frs02perfdatacomclientCurrent15StatOutPacketCountInvPortn
EkiOnOff,
pm200frs02perfdatacomclientCurrent15StatOutPacketCountPortn
Counter64,
pm200frs02perfdatacomclientCurrent15StatOutCrcCountInvPortn
EkiOnOff,
pm200frs02perfdatacomclientCurrent15StatOutCrcCountPortn
Counter64,
pm200frs02perfdatacomclientCurrent15StatInPacketCountInvPortn
EkiOnOff,
pm200frs02perfdatacomclientCurrent15StatInPacketCountPortn
Counter64,
pm200frs02perfdatacomclientCurrent15StatInCrcCountInvPortn
EkiOnOff,
pm200frs02perfdatacomclientCurrent15StatInCrcCountPortn
Counter64
}
pm200frs02PerfDatacomClientCurrent15StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfDatacomClientCurrent15Stat
table
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 1 }
pm200frs02perfdatacomclientCurrent15StatOutPacketCountInvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 15-min Output Packet
counter inv. :This OID indicates
that the current 15-min Output
Packets counter is invalid
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 30 }
pm200frs02perfdatacomclientCurrent15StatOutPacketCountPortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 15-min Output Packet
counter :This OID gives the current
15-min Output Packets counter value
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 31 }
pm200frs02perfdatacomclientCurrent15StatOutCrcCountInvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 15-min Output CRC
counter inv. :This OID indicates
that the current 15-min Output
CRC counter is invalid
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 28 }
pm200frs02perfdatacomclientCurrent15StatOutCrcCountPortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 15-min Output CRC
counter :This OID gives the current
15-min Output CRC counter value
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 29 }
pm200frs02perfdatacomclientCurrent15StatInPacketCountInvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 15-min Input Packet
counter inv. :This OID indicates
that the current 15-min Input Packet
counter is invalid
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 6 }
pm200frs02perfdatacomclientCurrent15StatInPacketCountPortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 15-min Input Packet
counter :This OID gives the current
15-min Input Packet counter value
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 7 }
pm200frs02perfdatacomclientCurrent15StatInCrcCountInvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 15-min Input CRC
counter inv. :This OID indicates
that the current 15-min Input CRC
counter is invalid
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 4 }
pm200frs02perfdatacomclientCurrent15StatInCrcCountPortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 15-min Input CRC
counter :This OID gives the current
15-min Input CRC counter value
"
::= { pm200frs02PerfDatacomClientCurrent15StatEntry 5 }
--- *****************************************************
--- Leaf of the datacomClientPast15Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfDatacomClientPast15StatHistory articles
--- *********************************************************
pm200frs02PerfDatacomClientPast15StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfDatacomClientPast15StatHistory
Article
"
::= { pm200frs02MonPerfClient 880 }
pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfDatacomClientPast15StatHistory
table
"
INDEX { pm200frs02PerfDatacomClientPast15StatHistoryPort1Index }
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Table 1 }
Pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfDatacomClientPast15StatHistoryPort1Index
INTEGER,
pm200frs02perfdatacomclientPast15StatOutPacketCountInvPort1
EkiOnOff,
pm200frs02perfdatacomclientPast15StatOutPacketCountPort1
Counter64,
pm200frs02perfdatacomclientPast15StatOutCrcCountInvPort1
EkiOnOff,
pm200frs02perfdatacomclientPast15StatOutCrcCountPort1
Counter64,
pm200frs02perfdatacomclientPast15StatInPacketCountInvPort1
EkiOnOff,
pm200frs02perfdatacomclientPast15StatInPacketCountPort1
Counter64,
pm200frs02perfdatacomclientPast15StatInCrcCountInvPort1
EkiOnOff,
pm200frs02perfdatacomclientPast15StatInCrcCountPort1
Counter64
}
pm200frs02PerfDatacomClientPast15StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfDatacomClientPast15StatHistory
table
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 1 }
pm200frs02perfdatacomclientPast15StatOutPacketCountInvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 15-min Output Packet
counter inv. :This OID indicates
that the past 15-min Output Packets
counter is invalid
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 30 }
pm200frs02perfdatacomclientPast15StatOutPacketCountPort1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 15-min Output Packet
counter :This OID gives the past
15-min Output Packets counter value
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 31 }
pm200frs02perfdatacomclientPast15StatOutCrcCountInvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 15-min Output CRC
counter inv. :This OID indicates
that the past 15-min Output CRC
counter is invalid
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 28 }
pm200frs02perfdatacomclientPast15StatOutCrcCountPort1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 15-min Output CRC
counter :This OID gives the past
15-min Output CRC counter value
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 29 }
pm200frs02perfdatacomclientPast15StatInPacketCountInvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 15-min Input Packet
counter inv. :This OID indicates
that the past 15-min Input Packet
counter is invalid
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 6 }
pm200frs02perfdatacomclientPast15StatInPacketCountPort1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 15-min Input Packet
counter :This OID gives the past
15-min Input Packet counter value
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 7 }
pm200frs02perfdatacomclientPast15StatInCrcCountInvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 15-min Input CRC counter
inv. :This OID indicates that the
past 15-min Input CRC counter is
invalid
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 4 }
pm200frs02perfdatacomclientPast15StatInCrcCountPort1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 15-min Input CRC counter
:This OID gives the past 15-min
Input CRC counter value
"
::= { pm200frs02PerfDatacomClientPast15StatHistoryPort1Entry 5 }
--- *****************************************************
--- Leaf of the datacomClientCurrent24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfDatacomClientCurrent24Stat articles
--- *********************************************************
pm200frs02PerfDatacomClientCurrent24StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfDatacomClientCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfDatacomClientCurrent24Stat
Article
"
::= { pm200frs02MonPerfClient 912 }
pm200frs02PerfDatacomClientCurrent24StatEntry OBJECT-TYPE
SYNTAX Pm200frs02PerfDatacomClientCurrent24StatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfDatacomClientCurrent24Stat
table
"
INDEX { pm200frs02PerfDatacomClientCurrent24StatIndex }
::= { pm200frs02PerfDatacomClientCurrent24StatTable 1 }
Pm200frs02PerfDatacomClientCurrent24StatEntry ::=
SEQUENCE {
pm200frs02PerfDatacomClientCurrent24StatIndex
INTEGER,
pm200frs02perfdatacomclientCurrent24StatOutPacketCountInvPortn
EkiOnOff,
pm200frs02perfdatacomclientCurrent24StatOutPacketCountPortn
Counter64,
pm200frs02perfdatacomclientCurrent24StatOutCrcCountInvPortn
EkiOnOff,
pm200frs02perfdatacomclientCurrent24StatOutCrcCountPortn
Counter64,
pm200frs02perfdatacomclientCurrent24StatInPacketCountInvPortn
EkiOnOff,
pm200frs02perfdatacomclientCurrent24StatInPacketCountPortn
Counter64,
pm200frs02perfdatacomclientCurrent24StatInCrcCountInvPortn
EkiOnOff,
pm200frs02perfdatacomclientCurrent24StatInCrcCountPortn
Counter64
}
pm200frs02PerfDatacomClientCurrent24StatIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfDatacomClientCurrent24Stat
table
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 1 }
pm200frs02perfdatacomclientCurrent24StatOutPacketCountInvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 24-hours Output
Packet counter inv. :This OID indicates
that the current 24-hours Output
Packets counter is invalid
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 30 }
pm200frs02perfdatacomclientCurrent24StatOutPacketCountPortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 24-hours Output
Packet counter :This OID gives
the current 24-hours Output Packets
counter value
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 31 }
pm200frs02perfdatacomclientCurrent24StatOutCrcCountInvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 24-hours Output
CRC counter inv. :This OID indicates
that the current 24-hours Output
CRC counter is invalid
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 28 }
pm200frs02perfdatacomclientCurrent24StatOutCrcCountPortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 24-hours Output
CRC counter :This OID gives the
current 24-hours Output CRC counter
value
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 29 }
pm200frs02perfdatacomclientCurrent24StatInPacketCountInvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 24-hours Input
Packet counter inv. :This OID
indicates that the current 24-hours
Input Packet counter is invalid
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 6 }
pm200frs02perfdatacomclientCurrent24StatInPacketCountPortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 24-hours Input
Packet counter :This OID gives
the current 24-hours Input Packet
counter value
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 7 }
pm200frs02perfdatacomclientCurrent24StatInCrcCountInvPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 24-hours Input
CRC counter inv. :This OID indicates
that the current 24-hours Input
CRC counter is invalid
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 4 }
pm200frs02perfdatacomclientCurrent24StatInCrcCountPortn OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Current 24-hours Input
CRC counter :This OID gives the
current 24-hours Input CRC counter
value
"
::= { pm200frs02PerfDatacomClientCurrent24StatEntry 5 }
--- *****************************************************
--- Leaf of the datacomClientPast24Stat
--- *****************************************************
--- *********************************************************
--- TABLE for the pm200frs02PerfDatacomClientPast24StatHistory articles
--- *********************************************************
pm200frs02PerfDatacomClientPast24StatHistoryPort1Table OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pm200frs02PerfDatacomClientPast24StatHistory
Article
"
::= { pm200frs02MonPerfClient 944 }
pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry OBJECT-TYPE
SYNTAX Pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pm200frs02PerfDatacomClientPast24StatHistory
table
"
INDEX { pm200frs02PerfDatacomClientPast24StatHistoryPort1Index }
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Table 1 }
Pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry ::=
SEQUENCE {
pm200frs02PerfDatacomClientPast24StatHistoryPort1Index
INTEGER,
pm200frs02perfdatacomclientPast24StatOutPacketCountInvPort1
EkiOnOff,
pm200frs02perfdatacomclientPast24StatOutPacketCountPort1
Counter64,
pm200frs02perfdatacomclientPast24StatOutCrcCountInvPort1
EkiOnOff,
pm200frs02perfdatacomclientPast24StatOutCrcCountPort1
Counter64,
pm200frs02perfdatacomclientPast24StatInPacketCountInvPort1
EkiOnOff,
pm200frs02perfdatacomclientPast24StatInPacketCountPort1
Counter64,
pm200frs02perfdatacomclientPast24StatInCrcCountInvPort1
EkiOnOff,
pm200frs02perfdatacomclientPast24StatInCrcCountPort1
Counter64
}
pm200frs02PerfDatacomClientPast24StatHistoryPort1Index OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pm200frs02PerfDatacomClientPast24StatHistory
table
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 1 }
pm200frs02perfdatacomclientPast24StatOutPacketCountInvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 24-hours Output Packet
counter inv. :This OID indicates
that the past 24-hours Output Packets
counter is invalid
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 30 }
pm200frs02perfdatacomclientPast24StatOutPacketCountPort1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 24-hours Output Packet
counter :This OID gives the past
24-hours Output Packets counter
value
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 31 }
pm200frs02perfdatacomclientPast24StatOutCrcCountInvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 24-hours Output CRC
counter inv. :This OID indicates
that the past 24-hours Output CRC
counter is invalid
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 28 }
pm200frs02perfdatacomclientPast24StatOutCrcCountPort1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 24-hours Output CRC
counter :This OID gives the past
24-hours Output CRC counter value
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 29 }
pm200frs02perfdatacomclientPast24StatInPacketCountInvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 24-hours Input Packet
counter inv. :This OID indicates
that the past 24-hours Input Packet
counter is invalid
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 6 }
pm200frs02perfdatacomclientPast24StatInPacketCountPort1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 24-hours Input Packet
counter :This OID gives the past
24-hours Input Packet counter value
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 7 }
pm200frs02perfdatacomclientPast24StatInCrcCountInvPort1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 24-hours Input CRC
counter inv. :This OID indicates
that the past 24-hours Input CRC
counter is invalid
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 4 }
pm200frs02perfdatacomclientPast24StatInCrcCountPort1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Past 24-hours Input CRC
counter :This OID gives the past
24-hours Input CRC counter value
"
::= { pm200frs02PerfDatacomClientPast24StatHistoryPort1Entry 5 }
pm200frs02PerfEnable OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Perf. Mon. Enable :This OID enables
the Performance Monitoring application
"
::= { pm200frs02MonPerfSync 257 }
pm200frs02Perf15minSync OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Perf. Mon. 15-min sync. :This
OID must be used in external synchronisation
mode only to send a 15-min synchronisation
command
"
::= { pm200frs02MonPerfSync 259 }
pm200frs02Perf24hSync OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Perf. Mon. 24-hours sync. :This
OID must be used in external synchronisation
mode only to send a 24-hours synchronisation
command
"
::= { pm200frs02MonPerfSync 260 }
pm200frs02Perf15MinShort OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
15-min period is short :This OID
indicates that the 15-min period
lasts less than 890 seconds
"
::= { pm200frs02MonPerfTimeStamp 1 }
pm200frs02Perf15MinLong OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
15-min period is long :This OID
indicates that the 15-min period
lasts more than 910 seconds
"
::= { pm200frs02MonPerfTimeStamp 2 }
pm200frs02Perf24HoursShort OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
24-hours period is short :This
OID indicates that 24-hours period
lasts less than 86390 seconds
"
::= { pm200frs02MonPerfTimeStamp 5 }
pm200frs02Perf24HoursLong OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
24-hours period is long :This
OID indicates that 24-hours period
lasts more than 86410 seconds
"
::= { pm200frs02MonPerfTimeStamp 6 }
pm200frs02PerfCurrent15MinElapsedTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Current 15min period Elapsed Time
:This OID gives the number of
seconds elapsed in the current
15-minutes period
"
::= { pm200frs02MonPerfTimeStamp 7 }
pm200frs02PerfCurrent24HoursElapsedTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Current 24hours period Elapsed
Time :This OID gives the number
of seconds elapsed in the current
24-hours period
"
::= { pm200frs02MonPerfTimeStamp 8 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- DOWNLOAD
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the restartProcess article
--- *****************************************************
pm200frs02DwlrestartProcess OBJECT IDENTIFIER ::= { pm200frs02DwlOther 0 }
pm200frs02DwlColdRestartProcessed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Cold Restart :This OID indicates
that the module last restart was
a Cold RESTART
"
::= { pm200frs02DwlrestartProcess 2 }
pm200frs02DwlWarmRestartProcessed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warm Restart :This OID indicates
that the module last restart was
a Warm RESTART
"
::= { pm200frs02DwlrestartProcess 1 }
--- *****************************************************
--- LEAF for the swBanksUsed article
--- *****************************************************
pm200frs02DwlswBanksUsed OBJECT IDENTIFIER ::= { pm200frs02DwlOther 1 }
pm200frs02DwlSwBank2Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SW bank 2 loaded :This OID indicates
a software is loaded in SW bank
2 <Help> This status indicates
if the SW bank 2 contains SW package
"
::= { pm200frs02DwlswBanksUsed 6 }
pm200frs02DwlSwBank1Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SW bank 1 loaded :This OID indicates
a software is loaded in SW bank
1 <Help> This status indicates
if the SW bank 1 contains SW package
"
::= { pm200frs02DwlswBanksUsed 5 }
pm200frs02DwlSwBank2Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SW bank 2 active :This OID indicates
the module is working on SW bank
2 <Help> This status indicates
if the SW bank 2 is active or standby
"
::= { pm200frs02DwlswBanksUsed 2 }
pm200frs02DwlSwBank1Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SW bank 1 active :This OID indicates
the module is working on SW bank
1 <Help> This status indicates
if the SW bank 1 is active or standby
"
::= { pm200frs02DwlswBanksUsed 1 }
--- *****************************************************
--- LEAF for the gwBanksUsed article
--- *****************************************************
pm200frs02DwlgwBanksUsed OBJECT IDENTIFIER ::= { pm200frs02DwlOther 2 }
pm200frs02DwlGwBank4Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 4 loaded :This OID indicates
a gateware is loaded in GW bank
4
"
::= { pm200frs02DwlgwBanksUsed 8 }
pm200frs02DwlGwBank3Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 3 loaded :This OID indicates
a gateware is loaded in GW bank
3 <Help> This status indicates
if the GW bank 3 contains GW package
"
::= { pm200frs02DwlgwBanksUsed 7 }
pm200frs02DwlGwBank2Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 2 loaded :This OID indicates
a gateware is loaded in GW bank
2
"
::= { pm200frs02DwlgwBanksUsed 6 }
pm200frs02DwlGwBank1Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 1 loaded :This OID indicates
a gateware is loaded in GW bank
1 <Help> This status indicates
if the GW bank 1 contains GW package
"
::= { pm200frs02DwlgwBanksUsed 5 }
pm200frs02DwlGwBank4Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 4 active :This OID indicates
the module is working on GW bank
4
"
::= { pm200frs02DwlgwBanksUsed 4 }
pm200frs02DwlGwBank3Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 3 active :This OID indicates
the module is working on GW bank
3 <Help> This status indicates
if the GW bank 3 is active or standby
"
::= { pm200frs02DwlgwBanksUsed 3 }
pm200frs02DwlGwBank2Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 2 active :This OID indicates
the module is working on GW bank
2
"
::= { pm200frs02DwlgwBanksUsed 2 }
pm200frs02DwlGwBank1Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 1 active :This OID indicates
the module is working on GW bank
1 <Help> This status indicates
if the GW bank 1 is active or standby
"
::= { pm200frs02DwlgwBanksUsed 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group accessCAisCsf
--- *****************************************************
pm200frs02CfgAccessCAisCsf OBJECT IDENTIFIER ::= { pm200frs02Config 1 }
--- *****************************************************
--- LEAF for the table 0012
--- *****************************************************
pm200frs02CfgClientcaiscsfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CfgClientcaiscsfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm200frs02CfgAccessCAisCsf 1 }
pm200frs02CfgClientcaiscsfEntry OBJECT-TYPE
SYNTAX Pm200frs02CfgClientcaiscsfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the accessCAisCsf
table
"
INDEX { pm200frs02CfgClientcaiscsfIndex }
::= { pm200frs02CfgClientcaiscsfTable 1 }
Pm200frs02CfgClientcaiscsfEntry ::=
SEQUENCE {
pm200frs02CfgClientcaiscsfIndex
INTEGER,
pm200frs02CfgReservePortn
Unsigned32
}
pm200frs02CfgClientcaiscsfIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the clientcaiscsf
table
"
::= { pm200frs02CfgClientcaiscsfEntry 1 }
pm200frs02CfgReservePortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
CAIS mode on Client Port :This
register enables/disables port
laser shutdown on CAIS insertion
condition
"
::= { pm200frs02CfgClientcaiscsfEntry 3 }
--- *****************************************************
--- LEAF for the table Group startup
--- *****************************************************
pm200frs02CfgStartup OBJECT IDENTIFIER ::= { pm200frs02Config 2 }
--- *****************************************************
--- LEAF for the table 2110
--- *****************************************************
pm200frs02CfgClientStartupTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CfgClientStartupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm200frs02CfgStartup 1 }
pm200frs02CfgClientStartupEntry OBJECT-TYPE
SYNTAX Pm200frs02CfgClientStartupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the startup
table
"
INDEX { pm200frs02CfgClientStartupIndex }
::= { pm200frs02CfgClientStartupTable 1 }
Pm200frs02CfgClientStartupEntry ::=
SEQUENCE {
pm200frs02CfgClientStartupIndex
INTEGER,
pm200frs02CfgSystConfPortPortn
Unsigned32,
pm200frs02CfgNetConfPortPortn
Unsigned32,
pm200frs02CfgOptionsPortPortn
Unsigned32
}
pm200frs02CfgClientStartupIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the clientStartup
table
"
::= { pm200frs02CfgClientStartupEntry 1 }
pm200frs02CfgSystConfPortPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client Port
:This register configures the
default initialisation settings
on the port.
"
::= { pm200frs02CfgClientStartupEntry 3 }
pm200frs02CfgNetConfPortPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Client Port
:This register configures the
default initialisation settings
on the port.
"
::= { pm200frs02CfgClientStartupEntry 4 }
pm200frs02CfgOptionsPortPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Options on Client Port
:This register configures the default
options on the port.
"
::= { pm200frs02CfgClientStartupEntry 14 }
--- *****************************************************
--- LEAF for the table 2190
--- *****************************************************
pm200frs02CfgLineStartupTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CfgLineStartupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm200frs02CfgStartup 2 }
pm200frs02CfgLineStartupEntry OBJECT-TYPE
SYNTAX Pm200frs02CfgLineStartupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the startup
table
"
INDEX { pm200frs02CfgLineStartupIndex }
::= { pm200frs02CfgLineStartupTable 1 }
Pm200frs02CfgLineStartupEntry ::=
SEQUENCE {
pm200frs02CfgLineStartupIndex
INTEGER,
pm200frs02CfgSystConfLinePortn
Unsigned32,
pm200frs02CfgOptionsLinePortn
Unsigned32
}
pm200frs02CfgLineStartupIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the lineStartup
table
"
::= { pm200frs02CfgLineStartupEntry 1 }
pm200frs02CfgSystConfLinePortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line :This
register configures the default
initialisation settings on Line
"
::= { pm200frs02CfgLineStartupEntry 3 }
pm200frs02CfgOptionsLinePortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Options on Line :This
register configures the default
options on the line
"
::= { pm200frs02CfgLineStartupEntry 14 }
--- *****************************************************
--- LEAF for the table 21AB
--- *****************************************************
pm200frs02CfgXfpTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CfgXfpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm200frs02CfgStartup 3 }
pm200frs02CfgXfpEntry OBJECT-TYPE
SYNTAX Pm200frs02CfgXfpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the startup
table
"
INDEX { pm200frs02CfgXfpIndex }
::= { pm200frs02CfgXfpTable 1 }
Pm200frs02CfgXfpEntry ::=
SEQUENCE {
pm200frs02CfgXfpIndex
INTEGER,
pm200frs02CfgSystConfMsaLinePortn
Unsigned32
}
pm200frs02CfgXfpIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the xfp table
"
::= { pm200frs02CfgXfpEntry 1 }
pm200frs02CfgSystConfMsaLinePortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on MSA :This
register configures the default
initialisation settings on MSA
"
::= { pm200frs02CfgXfpEntry 3 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pm200frs02CfgLabels OBJECT IDENTIFIER ::= { pm200frs02Config 3 }
--- *****************************************************
--- LEAF for the table 0003
--- *****************************************************
pm200frs02CfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm200frs02CfgLabels 1 }
pm200frs02CfgLabelclientEntry OBJECT-TYPE
SYNTAX Pm200frs02CfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pm200frs02CfgLabelclientIndex }
::= { pm200frs02CfgLabelclientTable 1 }
Pm200frs02CfgLabelclientEntry ::=
SEQUENCE {
pm200frs02CfgLabelclientIndex
INTEGER,
pm200frs02CfgLabelclientPortn
DisplayString
}
pm200frs02CfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pm200frs02CfgLabelclientEntry 1 }
pm200frs02CfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pm200frs02CfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table 0004
--- *****************************************************
pm200frs02CfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm200frs02CfgLabels 2 }
pm200frs02CfgLabellineEntry OBJECT-TYPE
SYNTAX Pm200frs02CfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pm200frs02CfgLabellineIndex }
::= { pm200frs02CfgLabellineTable 1 }
Pm200frs02CfgLabellineEntry ::=
SEQUENCE {
pm200frs02CfgLabellineIndex
INTEGER,
pm200frs02CfgLabellinePortn
DisplayString
}
pm200frs02CfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pm200frs02CfgLabellineEntry 1 }
pm200frs02CfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pm200frs02CfgLabellineEntry 3 }
--- *****************************************************
--- LEAF for the table Group startuptlh
--- *****************************************************
pm200frs02CfgStartuptlh OBJECT IDENTIFIER ::= { pm200frs02Config 4 }
--- *****************************************************
--- LEAF for the table 25AB
--- *****************************************************
pm200frs02CfgOtxtlhTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CfgOtxtlhEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm200frs02CfgStartuptlh 1 }
pm200frs02CfgOtxtlhEntry OBJECT-TYPE
SYNTAX Pm200frs02CfgOtxtlhEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the startuptlh
table
"
INDEX { pm200frs02CfgOtxtlhIndex }
::= { pm200frs02CfgOtxtlhTable 1 }
Pm200frs02CfgOtxtlhEntry ::=
SEQUENCE {
pm200frs02CfgOtxtlhIndex
INTEGER,
pm200frs02CfgLinePwrLaserPortn
Unsigned32,
pm200frs02CfgLineFCurrentPortn
Unsigned32,
pm200frs02CfgLineGridCurrentPortn
Unsigned32,
pm200frs02CfgFPortn
Unsigned32,
pm200frs02CfgRxLineFCurrentPortn
Unsigned32
}
pm200frs02CfgOtxtlhIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the otxtlh
table
"
::= { pm200frs02CfgOtxtlhEntry 1 }
pm200frs02CfgLinePwrLaserPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Defaut Line output Power :This
register configures the start-up
output power of the Line tranceiver
(Unit = dBm)
"
::= { pm200frs02CfgOtxtlhEntry 6 }
pm200frs02CfgLineFCurrentPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line transceiver Tx Channel
:This register configures the start-up
laser channel of the Line Tx transceiver
"
::= { pm200frs02CfgOtxtlhEntry 7 }
pm200frs02CfgLineGridCurrentPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line transceiver Grid
:This register configures the
start-up laser grid of the Line
transceiver
"
::= { pm200frs02CfgOtxtlhEntry 8 }
pm200frs02CfgFPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line TRX lowest Freq :This
register configures the start-up
lowest frequency of the Line transceiver
"
::= { pm200frs02CfgOtxtlhEntry 9 }
pm200frs02CfgRxLineFCurrentPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Line transceiver Rx Channel
:This register configures the start-up
laser channel of the Line Rx transceiver
"
::= { pm200frs02CfgOtxtlhEntry 10 }
--- *****************************************************
--- LEAF for the table Group other
--- *****************************************************
pm200frs02CfgOther OBJECT IDENTIFIER ::= { pm200frs02Config 5 }
--- *****************************************************
--- LEAF for the table 2300
--- *****************************************************
pm200frs02tablemoduleOther OBJECT IDENTIFIER ::= { pm200frs02CfgOther 1 }
pm200frs02Cfgmode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on Module :This
register selects the configuration
mode of the module
"
::= { pm200frs02tablemoduleOther 2 }
pm200frs02CfgfanLowSpeedThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on Module :This
register selects the speed threshold
of the fan's
"
::= { pm200frs02tablemoduleOther 3 }
pm200frs02CfgfanHighSpeedThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on Module :This
register selects the speed threshold
of the fan's
"
::= { pm200frs02tablemoduleOther 4 }
pm200frs02CfgmoduleMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on Module :This
register selects the configuration
mode of the module
"
::= { pm200frs02tablemoduleOther 5 }
--- *****************************************************
--- LEAF for the table Group startuptablefive
--- *****************************************************
pm200frs02CfgStartuptablefive OBJECT IDENTIFIER ::= { pm200frs02Config 6 }
--- *****************************************************
--- LEAF for the table 0005
--- *****************************************************
pm200frs02CfgOtxtlhcapabilitiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pm200frs02CfgOtxtlhcapabilitiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pm200frs02CfgStartuptablefive 1 }
pm200frs02CfgOtxtlhcapabilitiesEntry OBJECT-TYPE
SYNTAX Pm200frs02CfgOtxtlhcapabilitiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the startuptablefive
table
"
INDEX { pm200frs02CfgOtxtlhcapabilitiesIndex }
::= { pm200frs02CfgOtxtlhcapabilitiesTable 1 }
Pm200frs02CfgOtxtlhcapabilitiesEntry ::=
SEQUENCE {
pm200frs02CfgOtxtlhcapabilitiesIndex
INTEGER,
pm200frs02CfgComponentTypePortn
Unsigned32,
pm200frs02CfgMiscellaneousPortn
Unsigned32,
pm200frs02CfgFirstChannelPortn
Unsigned32,
pm200frs02CfgLastChannelPortn
Unsigned32,
pm200frs02CfgGridPortn
Unsigned32
}
pm200frs02CfgOtxtlhcapabilitiesIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the otxtlhcapabilities
table
"
::= { pm200frs02CfgOtxtlhcapabilitiesEntry 1 }
pm200frs02CfgComponentTypePortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Component parameters :This OID
defines the component parameters
"
::= { pm200frs02CfgOtxtlhcapabilitiesEntry 3 }
pm200frs02CfgMiscellaneousPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Miscellaneous default settings
:This OID defines the miscellaneous
parameters
"
::= { pm200frs02CfgOtxtlhcapabilitiesEntry 4 }
pm200frs02CfgFirstChannelPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Number of the first channel of
the component :This OID defines
the first channel number of the
PM
"
::= { pm200frs02CfgOtxtlhcapabilitiesEntry 5 }
pm200frs02CfgLastChannelPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Number of the last channel of
the component :This OID defines
the last channel number of the
PM
"
::= { pm200frs02CfgOtxtlhcapabilitiesEntry 6 }
pm200frs02CfgGridPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Grid value of the component :This
OID defines the grid of the PM
"
::= { pm200frs02CfgOtxtlhcapabilitiesEntry 7 }
pm200frs02CfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pm200frs02Config 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pm200frs02trapPortNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last port which generates a trap"
::= { pm200frs02traps 2 }
pm200frs02trapLineNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Line which generates a trap"
::= { pm200frs02traps 3 }
pm200frs02trapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pm200frs02traps 4 }
--- *****************************************************
--- LINE TRAPS
--- *****************************************************
pm200frs02LineTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmLineDdmWarningPortn, pm200frs02trapLineNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Not urgent Line default is activated"
::= { pm200frs02traps 30 }
pm200frs02LineTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmLineDdmWarningPortn, pm200frs02trapLineNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Not urgent Line default disappeared"
::= { pm200frs02traps 31 }
pm200frs02LineTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmLineDdmAlmPortn, pm200frs02trapLineNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Urgent Line default is activated"
::= { pm200frs02traps 32 }
pm200frs02LineTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmLineDdmAlmPortn, pm200frs02trapLineNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Urgent Line default disappeared"
::= { pm200frs02traps 33 }
pm200frs02LineTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmLineFailPortn , pm200frs02AlmLineHwFailPortn , pm200frs02trapLineNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Critical Line default is activated"
::= { pm200frs02traps 34 }
pm200frs02LineTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmLineFailPortn , pm200frs02AlmLineHwFailPortn , pm200frs02trapLineNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Critical Line default disappeared"
::= { pm200frs02traps 35 }
--- *****************************************************
--- CLIENT TRAPS
--- *****************************************************
pm200frs02ClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmSfpDdmWarningPortn, pm200frs02trapPortNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Not urgent client default is activated"
::= { pm200frs02traps 40 }
pm200frs02ClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmSfpDdmWarningPortn, pm200frs02trapPortNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Not urgent client default disappeared"
::= { pm200frs02traps 41 }
pm200frs02ClientTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmSfpDdmAlmPortn, pm200frs02trapPortNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Urgent client default is activated"
::= { pm200frs02traps 42 }
pm200frs02ClientTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmSfpDdmAlmPortn, pm200frs02trapPortNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Urgent client default disappeared"
::= { pm200frs02traps 43 }
pm200frs02ClientTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmFailAccPortn, pm200frs02AlmHwFailAccPortn, pm200frs02trapPortNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Critical client default is activated"
::= { pm200frs02traps 44 }
pm200frs02ClientTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmFailAccPortn, pm200frs02AlmHwFailAccPortn, pm200frs02trapPortNumber, pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Critical client default disappeared"
::= { pm200frs02traps 45 }
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pm200frs02PowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmDefFuseB, pm200frs02AlmDefFuseA , pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Urgent power supply default is activated"
::= { pm200frs02traps 50 }
pm200frs02PowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pm200frs02AlmDefFuseB, pm200frs02AlmDefFuseA , pm200frs02trapBoardNumber}
STATUS current
DESCRIPTION "Urgent power supply default disappeared"
::= { pm200frs02traps 51 }