5794 lines
145 KiB
Plaintext
5794 lines
145 KiB
Plaintext
-- *****************************************************************
|
||
-- EKINOPS-Pm1001lhr.TXT: MIB
|
||
--
|
||
--MIB Part Number:3MI00011AIAD
|
||
--MIB Version:02
|
||
--
|
||
-- Copyright (c) 2016 by Ekinops
|
||
-- All rights reserved.
|
||
--
|
||
-- *****************************************************************
|
||
|
||
EKINOPS-Pm1001lhr-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
ekinops,
|
||
EkiState,
|
||
EkiOnOff,
|
||
EkiMode,
|
||
EkiProtocol,
|
||
EkiApiState,
|
||
EkiSynchroMode,
|
||
EkiMeasureType
|
||
FROM EKINOPS-MIB
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Unsigned32,
|
||
Integer32,
|
||
Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION,
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
modulePm1001lhr MODULE-IDENTITY
|
||
LAST-UPDATED "201606020000Z"
|
||
ORGANIZATION "Ekinops"
|
||
CONTACT-INFO
|
||
"Ekinops
|
||
|
||
3, rue Blaise Pascal
|
||
F-22300 Lannion / FRANCE
|
||
|
||
Tel : +33 (0)2 96 05 00 30
|
||
Fax : +33 (0)2 96 48 62 39
|
||
|
||
E-mail: support@ekinops.net"
|
||
DESCRIPTION
|
||
"MIB for managing Ekinops modules with PM1001LHR software"
|
||
REVISION "200702010000Z"
|
||
DESCRIPTION
|
||
"Initial Version."
|
||
REVISION "200705310000Z"
|
||
DESCRIPTION
|
||
"Using EkiProtocol instead of EkiLineProtocol."
|
||
REVISION "200706290000Z"
|
||
DESCRIPTION
|
||
"Add DCC alarms."
|
||
REVISION "200712050000Z"
|
||
DESCRIPTION
|
||
"Update Ekinops address,Helps on objects, Ports Labels"
|
||
REVISION "200811270000Z"
|
||
DESCRIPTION
|
||
"DCC storm info suppress"
|
||
REVISION "200902060000Z"
|
||
DESCRIPTION
|
||
"Add OTX-TLH features"
|
||
REVISION "200910070000Z"
|
||
DESCRIPTION
|
||
"Add Condtype parameters"
|
||
REVISION "201002150000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS"
|
||
REVISION "201102030000Z"
|
||
DESCRIPTION
|
||
"Formulas in comments and Event on XFP init"
|
||
REVISION "201207030000Z"
|
||
DESCRIPTION
|
||
"Minor cosmetic updates"
|
||
REVISION "201403280000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS completion"
|
||
REVISION "201501200000Z"
|
||
DESCRIPTION
|
||
"Labels cosmetic updates"
|
||
REVISION "201605200000Z"
|
||
DESCRIPTION
|
||
"New AlarmType – synthesisAlarm (12)"
|
||
REVISION "201606020000Z"
|
||
DESCRIPTION
|
||
"Capabilities objects of Table 5"
|
||
::= { ekinops 22 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF LEVEL 2
|
||
--- *****************************************************
|
||
|
||
|
||
pm1001lhralarms OBJECT IDENTIFIER ::= { modulePm1001lhr 2 }
|
||
pm1001lhrAlmOther OBJECT IDENTIFIER ::= { pm1001lhralarms 1 }
|
||
pm1001lhrAlmOtherNurg OBJECT IDENTIFIER ::= { pm1001lhrAlmOther 1 }
|
||
pm1001lhrAlmOtherUrg OBJECT IDENTIFIER ::= { pm1001lhrAlmOther 2 }
|
||
pm1001lhrAlmOtherCrit OBJECT IDENTIFIER ::= { pm1001lhrAlmOther 3 }
|
||
|
||
pm1001lhrAlmClient OBJECT IDENTIFIER ::= { pm1001lhralarms 2 }
|
||
pm1001lhrAlmClientNurg OBJECT IDENTIFIER ::= { pm1001lhrAlmClient 1 }
|
||
pm1001lhrAlmClientUrg OBJECT IDENTIFIER ::= { pm1001lhrAlmClient 2 }
|
||
pm1001lhrAlmClientCrit OBJECT IDENTIFIER ::= { pm1001lhrAlmClient 3 }
|
||
|
||
pm1001lhrAlmLine OBJECT IDENTIFIER ::= { pm1001lhralarms 3 }
|
||
pm1001lhrAlmLineNurg OBJECT IDENTIFIER ::= { pm1001lhrAlmLine 1 }
|
||
pm1001lhrAlmLineUrg OBJECT IDENTIFIER ::= { pm1001lhrAlmLine 2 }
|
||
pm1001lhrAlmLineCrit OBJECT IDENTIFIER ::= { pm1001lhrAlmLine 3 }
|
||
|
||
|
||
|
||
|
||
|
||
pm1001lhrmeasures OBJECT IDENTIFIER ::= { modulePm1001lhr 3 }
|
||
pm1001lhrMesrOther OBJECT IDENTIFIER ::= { pm1001lhrmeasures 1 }
|
||
pm1001lhrMesrClient OBJECT IDENTIFIER ::= { pm1001lhrmeasures 2 }
|
||
pm1001lhrMesrLine OBJECT IDENTIFIER ::= { pm1001lhrmeasures 3 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrcounters OBJECT IDENTIFIER ::= { modulePm1001lhr 4 }
|
||
pm1001lhrCntOther OBJECT IDENTIFIER ::= { pm1001lhrcounters 1 }
|
||
pm1001lhrCntClient OBJECT IDENTIFIER ::= { pm1001lhrcounters 2 }
|
||
pm1001lhrCntLine OBJECT IDENTIFIER ::= { pm1001lhrcounters 3 }
|
||
|
||
|
||
pm1001lhrcontrolsWrite OBJECT IDENTIFIER ::= { modulePm1001lhr 6 }
|
||
pm1001lhrCtrlOther OBJECT IDENTIFIER ::= { pm1001lhrcontrolsWrite 1 }
|
||
pm1001lhrCtrlClient OBJECT IDENTIFIER ::= { pm1001lhrcontrolsWrite 2 }
|
||
pm1001lhrCtrlLine OBJECT IDENTIFIER ::= { pm1001lhrcontrolsWrite 3 }
|
||
|
||
pm1001lhrri OBJECT IDENTIFIER ::= { modulePm1001lhr 7 }
|
||
pm1001lhrriTable OBJECT IDENTIFIER ::= { pm1001lhrri 1 }
|
||
|
||
pm1001lhrdownload OBJECT IDENTIFIER ::= { modulePm1001lhr 8 }
|
||
pm1001lhrDwlOther OBJECT IDENTIFIER ::= { pm1001lhrdownload 1 }
|
||
pm1001lhrDwlClient OBJECT IDENTIFIER ::= { pm1001lhrdownload 2 }
|
||
pm1001lhrDwlLine OBJECT IDENTIFIER ::= { pm1001lhrdownload 3 }
|
||
|
||
|
||
pm1001lhrConfig OBJECT IDENTIFIER ::= { modulePm1001lhr 9 }
|
||
|
||
pm1001lhrtraps OBJECT IDENTIFIER ::= { modulePm1001lhr 10 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- TEXTUAL-CONVENTION
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
Pm1001lhrOtxMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on OTX-TLH on line ports"
|
||
SYNTAX INTEGER {
|
||
otx80mode(1),
|
||
otx60mode(2),
|
||
otxadjustmode(4),
|
||
}
|
||
|
||
Pm1001lhrOtxGrid ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different grids on OTX-TLH on line ports"
|
||
SYNTAX INTEGER {
|
||
otxgrid200(200),
|
||
otxgrid100(100),
|
||
otxgrid50(50),
|
||
}
|
||
|
||
Pm1001lhrAdjustValue ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different values in Adjust mode on OTX-TLH on line ports"
|
||
SYNTAX INTEGER {
|
||
otxadjustvalue0(0),
|
||
otxadjustvalue1(1),
|
||
otxadjustvalue2(2),
|
||
otxadjustvalue3(3),
|
||
otxadjustvalue4(4),
|
||
otxadjustvalue5(5),
|
||
otxadjustvalue6(6),
|
||
otxadjustvalue7(7),
|
||
otxadjustvalue8(8),
|
||
otxadjustvalue9(9),
|
||
otxadjustvalue10(10),
|
||
}
|
||
|
||
Pm1001lhrOtxChannel ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Channel selection on OTX-TLH on line ports"
|
||
SYNTAX INTEGER {
|
||
|
||
}
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- REMOTE INVENTORY
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
pm1001lhrRinvReloadInventory OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reload the inventory: This OID triggers an
|
||
inventory reload."
|
||
::= { pm1001lhrri 2 }
|
||
|
||
pm1001lhrRinvHwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"HW platform description: This OID contains the
|
||
description of the Hardware platform."
|
||
::= { pm1001lhrri 3 }
|
||
|
||
pm1001lhrRinvModulePlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Module platform description: This OID contains the
|
||
description of the Module."
|
||
::= { pm1001lhrri 4 }
|
||
|
||
pm1001lhrRinvSwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SW platform description: This OID contains the
|
||
description of the Software platform."
|
||
::= { pm1001lhrri 5 }
|
||
|
||
pm1001lhrRinvGwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"GW platform desciption: This OID contains the
|
||
description of the Gateware platform."
|
||
::= { pm1001lhrri 6 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrRinvLineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrRinvLineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the XFPs on the selected module"
|
||
::= { pm1001lhrriTable 1 }
|
||
|
||
pm1001lhrRinvLineEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrRinvLineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the XFP table"
|
||
INDEX { pm1001lhrRinvLineIndex }
|
||
::= { pm1001lhrRinvLineTable 1 }
|
||
|
||
|
||
|
||
Pm1001lhrRinvLineEntry::=
|
||
SEQUENCE {
|
||
pm1001lhrRinvLineIndex
|
||
Integer32,
|
||
pm1001lhrRinvxfpLine
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pm1001lhrRinvLineIndex OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for XFP table"
|
||
::= { pm1001lhrRinvLineEntry 1 }
|
||
|
||
|
||
pm1001lhrRinvxfpLine OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the XFP: This OID contains the inventory for the XFP"
|
||
::= { pm1001lhrRinvLineEntry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- ALARMS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm0 article
|
||
--- *****************************************************
|
||
pm1001lhrAlmsynthAlm0 OBJECT IDENTIFIER ::= { pm1001lhrAlmOtherCrit 0 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrAlmDefFuseB OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse B Fail :This OID indicates
|
||
that the fuse of the power input
|
||
B is in fail condition <Help>
|
||
Status of the Fuse B <Condtype>
|
||
DEF_FUSE_B <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlm0 16 }
|
||
|
||
|
||
|
||
pm1001lhrAlmDefFuseA OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse A Fail :This OID indicates
|
||
that the fuse of the power input
|
||
A is in fail condition <Help>
|
||
Status of the Fuse A <Condtype>
|
||
DEF_FUSE_A <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlm0 15 }
|
||
|
||
|
||
|
||
pm1001lhrAlmModGlobFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Failure :This OID is set
|
||
on detection of a failure originating
|
||
from the PM <Condtype> MOD_GLOB_FAIL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlm0 9 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm2 article
|
||
--- *****************************************************
|
||
pm1001lhrAlmsynthAlm2 OBJECT IDENTIFIER ::= { pm1001lhrAlmOtherNurg 2 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrAlmCorrelatOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Not Used :This OID, when set,
|
||
indicates that alarm correlation
|
||
is not being performed. <Condtype>
|
||
CORRELAT_OFF <Probcause> other
|
||
(1) <Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlm2 4 }
|
||
|
||
|
||
|
||
pm1001lhrAlmConfTableLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Load :This OID
|
||
is at 1 during the loading of
|
||
configuration tables in the modules
|
||
RAM. <Condtype> CONF_TABLE_LOAD
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlm2 3 }
|
||
|
||
|
||
|
||
pm1001lhrAlmInvUpload OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Inventory Upload :This OID is
|
||
at 1 during the uploading of PM
|
||
inventory information. <Condtype>
|
||
INV_UPLOAD <Probcause> other (1)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlm2 2 }
|
||
|
||
|
||
|
||
pm1001lhrAlmConfTableSave OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Save :This OID
|
||
is at 1 during the saving of a
|
||
new configuration table in the
|
||
module Flash memory. <Condtype>
|
||
CONF_TABLE_SAVE <Probcause> other
|
||
(1) <Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlm2 1 }
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmsynthAlmLine articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmsynthAlmLineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmsynthAlmLineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmsynthAlmLine
|
||
Article
|
||
"
|
||
::= { pm1001lhrAlmLineCrit 7 }
|
||
|
||
|
||
pm1001lhrAlmsynthAlmLineEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmsynthAlmLineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmsynthAlmLine
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmsynthAlmLineIndex }
|
||
::= { pm1001lhrAlmsynthAlmLineTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmsynthAlmLineEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmsynthAlmLineIndex
|
||
INTEGER,
|
||
pm1001lhrAlmLineFailPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineDdmAlmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineDdmWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineLocalOosPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmXfpTxOffPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineHwFailPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmXfpInitNotComplPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmXfpAbsentPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmsynthAlmLineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmsynthAlmLine
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmLineFailPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port Failure :This OID indicates
|
||
a failure on the line port <Condtype>
|
||
LINE_FAIL <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 13 }
|
||
|
||
|
||
pm1001lhrAlmLineDdmAlmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Line Optical Module DDM
|
||
:This OID indicates an alarm is
|
||
present coming out of Line optical
|
||
interface DDM <Help> This alarm
|
||
indicates if a DDM Alarm has been
|
||
detected on the line transceiver
|
||
<Condtype> LINE_DDM_ALM <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 11 }
|
||
|
||
|
||
pm1001lhrAlmLineDdmWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Line Optical Module
|
||
DDM :This OID indicates a warning
|
||
is present coming out of Line optical
|
||
interface DDM <Help> This alarm
|
||
indicates if a DDM Warning has
|
||
been detected on the line transceiver
|
||
<Condtype> LINE_DDM_WARNING <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 10 }
|
||
|
||
|
||
pm1001lhrAlmLineLocalOosPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port In Service :This OID
|
||
indicates that the Line port is
|
||
In Service (1) of Out or Service
|
||
(2) <Help> This status indicates
|
||
if the line port is in service
|
||
<Condtype> LINE_LOCAL_OOS <Probcause>
|
||
informationalStatus(1000) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 7 }
|
||
|
||
|
||
pm1001lhrAlmXfpTxOffPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Laser Shutdown :This
|
||
OID indicates the line optical
|
||
output power is on <Help> This
|
||
status indicates if the line transceiver
|
||
laser is ON or OFF <Condtype> XFP_TX_OFF
|
||
<Probcause> other (1) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 6 }
|
||
|
||
|
||
pm1001lhrAlmLineHwFailPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port HW Failure :This OID
|
||
indicates a failure on line port,
|
||
most probably caused by a HW issue
|
||
<Condtype> LINE_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 5 }
|
||
|
||
|
||
pm1001lhrAlmXfpInitNotComplPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Module Ready :This
|
||
OID indicates that the optical
|
||
interface (XFP or OTX) is not
|
||
operational. <Help> This status
|
||
indicates if the line transceiver
|
||
has been correctly initialized
|
||
<Condtype> XFP_INIT_NOT_COMPL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2) <Event> ObjectCDINV
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 3 }
|
||
|
||
|
||
pm1001lhrAlmXfpAbsentPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Module Absent :This
|
||
OID indicates that the line optical
|
||
interface (XFP or OTX) is not plugged
|
||
in. <Help> This alarm indicates
|
||
if the line transceiver is present.
|
||
<Condtype> XFP_ABSENT <Probcause>
|
||
inputOutputDeviceError (24) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
<Event> ObjectCDINV
|
||
"
|
||
::= { pm1001lhrAlmsynthAlmLineEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmdfrmAlm articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmdfrmAlmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmdfrmAlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmdfrmAlm Article
|
||
"
|
||
::= { pm1001lhrAlmLineCrit 128 }
|
||
|
||
|
||
pm1001lhrAlmdfrmAlmEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmdfrmAlmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmdfrmAlm
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmdfrmAlmIndex }
|
||
::= { pm1001lhrAlmdfrmAlmTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmdfrmAlmEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmdfrmAlmIndex
|
||
INTEGER,
|
||
pm1001lhrAlmDwLofPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmDwOofPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmDwRdiDetPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmDwAisDetPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmdfrmAlmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmdfrmAlm
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmdfrmAlmEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmDwLofPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
SONET/SDH Line Loss Of Frame :This
|
||
OID indicates that a Loss Of Frame
|
||
has been detected on incoming input
|
||
signal <Help> This alarm indicates
|
||
if there is a Loss of Frame is
|
||
detected on the line input signal
|
||
<Condtype> DW_LOF_1 <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
integrityViolation (7) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmdfrmAlmEntry 5 }
|
||
|
||
|
||
pm1001lhrAlmDwOofPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
SONET/SDH Line Out Of Frame :This
|
||
OID indicates that an Out Of Frame
|
||
has been detected on incoming input
|
||
signal <Help> This alarm indicates
|
||
if there is a Out of Frame is detected
|
||
on the line input signal <Condtype>
|
||
DW_OOF_1 <Probcause> receiveFailure
|
||
(41) <Alarmtype> integrityViolation
|
||
(7) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmdfrmAlmEntry 4 }
|
||
|
||
|
||
pm1001lhrAlmDwRdiDetPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
MS-RDI/L-RDI Detected On Line
|
||
Input :This bit indicates that
|
||
an MS-RDI has been detected on
|
||
incoming OC-192c/STM-64c input
|
||
signal <Help> This alarm indicates
|
||
if there is a MS-RDI/L-RDI is detected
|
||
on the line input signal <Condtype>
|
||
DW_RDI_DET_1 <Probcause> remoteNodeTransmissionError
|
||
(43) <Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmdfrmAlmEntry 3 }
|
||
|
||
|
||
pm1001lhrAlmDwAisDetPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
MS-AIS/L-AIS Detected On Line
|
||
Input :This bit indicates that
|
||
an MS-AIS has been detected on
|
||
incoming OC-192c/STM-64c input
|
||
signal <Help> This alarm indicates
|
||
if there is a MS-AIS/L-AIS is detected
|
||
on the line input signal <Condtype>
|
||
DW_AIS_DET_1 <Probcause> receiveFailure
|
||
(41) <Alarmtype> operationalViolation
|
||
(8) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmdfrmAlmEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmdfrmBer articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmdfrmBerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmdfrmBerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmdfrmBer Article
|
||
"
|
||
::= { pm1001lhrAlmLineUrg 129 }
|
||
|
||
|
||
pm1001lhrAlmdfrmBerEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmdfrmBerEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmdfrmBer
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmdfrmBerIndex }
|
||
::= { pm1001lhrAlmdfrmBerTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmdfrmBerEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmdfrmBerIndex
|
||
INTEGER,
|
||
pm1001lhrAlmLineDegradePortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineSignalFailPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineSignalDegradePortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmdfrmBerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmdfrmBer
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmdfrmBerEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmLineDegradePortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fixed Line Signal Degrade :This
|
||
OID indicates that the line input
|
||
signal is DEGRADE. The assetion
|
||
hysteresis is fixed to 10-8 (assertion)
|
||
and 10-9 (de-assertion) <Condtype>
|
||
LINE_DEGRADE_1 <Probcause> degradedSignal
|
||
(13) <Alarmtype> qualityOfServiceAlarm
|
||
(3) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmdfrmBerEntry 6 }
|
||
|
||
|
||
pm1001lhrAlmLineSignalFailPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Custom Line Signal Fail :This
|
||
OID indicates that the line input
|
||
signal is FAIL. The assertion hysteresis
|
||
can be customized by the host <Condtype>
|
||
LINE_SIGNAL_FAIL_1 <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
integrityViolation (7) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmdfrmBerEntry 3 }
|
||
|
||
|
||
pm1001lhrAlmLineSignalDegradePortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Custom Line Signal Degrade :This
|
||
OID indicates that the line input
|
||
signal is DEGRADE. The assertion
|
||
hysteresis can customized by the
|
||
host <Condtype> LINE_SIGNAL_DEGRADE_1
|
||
<Probcause> degradedSignal (13)
|
||
<Alarmtype> qualityOfServiceAlarm
|
||
(3) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmdfrmBerEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmlineSyncAlarms articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmlineSyncAlarmsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmlineSyncAlarmsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmlineSyncAlarms
|
||
Article
|
||
"
|
||
::= { pm1001lhrAlmLineCrit 133 }
|
||
|
||
|
||
pm1001lhrAlmlineSyncAlarmsEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmlineSyncAlarmsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmlineSyncAlarms
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmlineSyncAlarmsIndex }
|
||
::= { pm1001lhrAlmlineSyncAlarmsTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmlineSyncAlarmsEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmlineSyncAlarmsIndex
|
||
INTEGER,
|
||
pm1001lhrAlmDwLosPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmUpLockerrPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmDwLockerrPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmlineSyncAlarmsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmlineSyncAlarms
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmlineSyncAlarmsEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmDwLosPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Input Loss Of Signal :This
|
||
OID indicates a loss of signal
|
||
on the 10 Gb/s input. <Help>
|
||
This alarm indicates if an optical
|
||
signal is detected on the line
|
||
transceiver input <Condtype> DW_LOS
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> physicalViolation (9)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineSyncAlarmsEntry 17 }
|
||
|
||
|
||
pm1001lhrAlmUpLockerrPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Upstream Clock Lock Error :This
|
||
OID indicates that the serializer
|
||
output 10 Gb/s clock multiplier
|
||
unit is not locked. <Condtype>
|
||
UP_LOCKERR <Probcause> receiveFailure
|
||
(41) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineSyncAlarmsEntry 14 }
|
||
|
||
|
||
pm1001lhrAlmDwLockerrPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Downstream Clock Lock Error :This
|
||
OID indicates that the deserializer
|
||
input 10 Gb/s clock recovery is
|
||
not locked. <Condtype> DW_LOCKERR
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineSyncAlarmsEntry 13 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the modInitFailLevel2 article
|
||
--- *****************************************************
|
||
pm1001lhrAlmmodInitFailLevel2 OBJECT IDENTIFIER ::= { pm1001lhrAlmOtherUrg 194 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrAlmSwInitFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
SW Init Fail :This OID indicates
|
||
that the SW intialization has caused
|
||
unknown intial conditions <Help>
|
||
This alarm indicates if the SW
|
||
module is correctly initialized
|
||
<Condtype> SW_INIT_FAIL <Probcause>
|
||
softwareError (47) <Alarmtype>
|
||
processingErrorAlarm (4) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel2 5 }
|
||
|
||
|
||
|
||
pm1001lhrAlmResetHwInitFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Reset HW Init Fail :This OID indicates
|
||
that the HW intialization has caused
|
||
unknown intial conditions <Help>
|
||
This alarm indicates if the HW
|
||
has been correctly initialized
|
||
<Condtype> RESET_HW_INIT_FAIL
|
||
<Probcause> softwareError (47)
|
||
<Alarmtype> processingErrorAlarm
|
||
(4) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel2 4 }
|
||
|
||
|
||
|
||
pm1001lhrAlmBootUndone OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Boot Undone :This OID indicates
|
||
that the boot has not been correctly
|
||
achieved <Help> This alarm indicates
|
||
if the module has correctly boot
|
||
<Condtype> BOOT_UNDONE <Probcause>
|
||
softwareError (47) <Alarmtype>
|
||
processingErrorAlarm (4) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel2 3 }
|
||
|
||
|
||
|
||
pm1001lhrAlmNextColdBootForced OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Next Cold Boot Forced :This OID
|
||
indicates that the next Reset will
|
||
be forced Cold <Help> This alarm
|
||
indicates that the next reset of
|
||
the module will be forced to cold
|
||
reset <Condtype> NEXT_COLD_BOOT_FORCED
|
||
<Probcause> informationalStatus(1000)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel2 2 }
|
||
|
||
|
||
|
||
pm1001lhrAlmLedFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Led Fail :This OID indicates that
|
||
Led register has not been correctly
|
||
initalized <Help> This alarm
|
||
indicates if the module LEDs are
|
||
correctly initialized <Condtype>
|
||
LED_FAIL <Probcause> softwareError
|
||
(47) <Alarmtype> processingErrorAlarm
|
||
(4) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the modInitFailLevel3 article
|
||
--- *****************************************************
|
||
pm1001lhrAlmmodInitFailLevel3 OBJECT IDENTIFIER ::= { pm1001lhrAlmOtherUrg 195 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrAlmLine2InitFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line2 Init Fail :This OID indicates
|
||
that the Line register subset has
|
||
not been correctly initialized
|
||
<Help> This alarm indicates
|
||
if the line port 2 is correctly
|
||
initialized <Condtype> LINE2_INIT_FAIL
|
||
<Probcause> softwareError (47)
|
||
<Alarmtype> processingErrorAlarm
|
||
(4) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel3 8 }
|
||
|
||
|
||
|
||
pm1001lhrAlmLine1InitFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line1 Init Fail :This OID indicates
|
||
that the Line registersvsubset
|
||
has not been correctly initialized
|
||
<Help> This alarm indicates if
|
||
the line port 1 is correctly initialized
|
||
<Condtype> LINE1_INIT_FAIL <Probcause>
|
||
softwareError (47) <Alarmtype>
|
||
processingErrorAlarm (4) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel3 7 }
|
||
|
||
|
||
|
||
pm1001lhrAlmXfp2InitFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
XFP2 Init Fail :This OID indicates
|
||
that the XFP has not been correctly
|
||
initialized <Help> This alarm
|
||
indicates if the line transceiver
|
||
2 is correctly initialized <Condtype>
|
||
XFP2_INIT_FAIL <Probcause> softwareError
|
||
(47) <Alarmtype> processingErrorAlarm
|
||
(4) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel3 6 }
|
||
|
||
|
||
|
||
pm1001lhrAlmXfp1InitFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
XFP1 Init Fail :This OID indicates
|
||
that the XFP has not been correctly
|
||
initialized <Help> This alarm
|
||
indicates if the line transceiver
|
||
1 is correctly initialized <Condtype>
|
||
XFP1_INIT_FAIL <Probcause> softwareError
|
||
(47) <Alarmtype> processingErrorAlarm
|
||
(4) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel3 5 }
|
||
|
||
|
||
|
||
pm1001lhrAlmInitModuleFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Init Module Fail :This OID indicates
|
||
that the Module has not been correctly
|
||
initialized <Help> This alarm
|
||
indicates if the SW module is correctly
|
||
initialized <Condtype> INIT_MODULE_FAIL
|
||
<Probcause> softwareError (47)
|
||
<Alarmtype> processingErrorAlarm
|
||
(4) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel3 3 }
|
||
|
||
|
||
|
||
pm1001lhrAlmObmTypeReadFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OBM Type Read Fail :This OID indicates
|
||
that OBM type has not been recognized
|
||
<Help> This alarm indicates if
|
||
the OBM board has been correctly
|
||
identified <Condtype> OBM_TYPE_READ_FAIL
|
||
<Probcause> softwareError (47)
|
||
<Alarmtype> processingErrorAlarm
|
||
(4) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel3 2 }
|
||
|
||
|
||
|
||
pm1001lhrAlmGwIdentFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW Ident Fail :This OID indicates
|
||
that GW identification has not
|
||
been read <Help> This alarm
|
||
indicates if the GW has been correctly
|
||
identified <Condtype> GW_IDENT_FAIL
|
||
<Probcause> softwareError (47)
|
||
<Alarmtype> processingErrorAlarm
|
||
(4) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmmodInitFailLevel3 1 }
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmlineXfp1Alarm articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmlineXfp1AlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmlineXfp1AlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmlineXfp1Alarm
|
||
Article
|
||
"
|
||
::= { pm1001lhrAlmLineUrg 208 }
|
||
|
||
|
||
pm1001lhrAlmlineXfp1AlarmEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmlineXfp1AlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmlineXfp1Alarm
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmlineXfp1AlarmIndex }
|
||
::= { pm1001lhrAlmlineXfp1AlarmTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmlineXfp1AlarmEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmlineXfp1AlarmIndex
|
||
INTEGER,
|
||
pm1001lhrAlmRxPowerHighAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmRxPowerLowAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTempHighAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTempLowAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxBiasHighAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxBiasLowAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxPowerHighAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxPowerLowAlarmPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmlineXfp1AlarmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmlineXfp1Alarm
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmRxPowerHighAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Rx Power High :Alarm
|
||
indicating that the XFP received
|
||
optical power is higher than the
|
||
threshold value written in the
|
||
XFP EEPROM <Condtype> RX_POWER_HIGH_ALARM_1
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 17 }
|
||
|
||
|
||
pm1001lhrAlmRxPowerLowAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Rx Power Low :Alarm
|
||
indicating that the XFP received
|
||
optical power is lower than the
|
||
threshold value written in the
|
||
XFP EEPROM <Condtype> RX_POWER_LOW_ALARM_1
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 16 }
|
||
|
||
|
||
pm1001lhrAlmTempHighAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Transceiver Temp High :Alarm
|
||
indicating that the XFP/OTX temperature
|
||
is higher than the threshold value
|
||
written in the XFP EEPROM <Condtype>
|
||
TEMP_HIGH_ALARM_1 <Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 9 }
|
||
|
||
|
||
pm1001lhrAlmTempLowAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Transceiver Temp Low :Alarm
|
||
indicating that the XFP/OTX temperature
|
||
is lower than the threshold value
|
||
written in the XFP/OTX EEPROM <Condtype>
|
||
TEMP_LOW_ALARM_1 <Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 8 }
|
||
|
||
|
||
pm1001lhrAlmTxBiasHighAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Transceiver Bias High :Alarm
|
||
indicating that the XFP/OTX transmitter
|
||
laser bias current is higher than
|
||
the threshold value written in
|
||
the XFP EEPROM <Condtype> TX_BIAS_HIGH_ALARM_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 5 }
|
||
|
||
|
||
pm1001lhrAlmTxBiasLowAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Transceiver Bias Low :Alarm
|
||
indicating that the XFP/OTX transmitter
|
||
laser bias current is lower than
|
||
the threshold value written in
|
||
the XFP/OTX EEPROM <Condtype>
|
||
TX_BIAS_LOW_ALARM_1 <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 4 }
|
||
|
||
|
||
pm1001lhrAlmTxPowerHighAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx Power High :Alarm
|
||
indicating that the XFP/OTX transmitter
|
||
transmitter output power is higher
|
||
than the threshold value written
|
||
in the XFP EEPROM <Condtype> TX_POWER_HIGH_ALARM_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 3 }
|
||
|
||
|
||
pm1001lhrAlmTxPowerLowAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx Power Low :Alarm
|
||
indicating that the XFP/OTX transmitter
|
||
transmitter output power is lower
|
||
than the threshold value written
|
||
in the XFP/OTX EEPROM <Condtype>
|
||
TX_POWER_LOW_ALARM_1 <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmlineXfp1Warnings articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmlineXfp1WarningsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmlineXfp1WarningsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmlineXfp1Warnings
|
||
Article
|
||
"
|
||
::= { pm1001lhrAlmLineNurg 209 }
|
||
|
||
|
||
pm1001lhrAlmlineXfp1WarningsEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmlineXfp1WarningsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmlineXfp1Warnings
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmlineXfp1WarningsIndex }
|
||
::= { pm1001lhrAlmlineXfp1WarningsTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmlineXfp1WarningsEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmlineXfp1WarningsIndex
|
||
INTEGER,
|
||
pm1001lhrAlmRxPowerHighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmRxPowerLowWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTempHighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTempLowWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxBiasHighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxBiasLowWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxPowerHighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxPowerLowWarningPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmlineXfp1WarningsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmlineXfp1Warnings
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmRxPowerHighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Rx Power High Warning
|
||
:Warning indicating that the XFP
|
||
received optical power is higher
|
||
than the threshold value written
|
||
in the XFP EEPROM <Condtype> RX_POWER_HIGH_WARNING_1
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 17 }
|
||
|
||
|
||
pm1001lhrAlmRxPowerLowWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Rx Power Low Warning
|
||
:Warning indicating that the XFP
|
||
received optical power is lower
|
||
than the threshold value written
|
||
in the XFP EEPROM <Condtype> RX_POWER_LOW_WARNING_1
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 16 }
|
||
|
||
|
||
pm1001lhrAlmTempHighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Transceiver Temp High Warning
|
||
:Warning indicating that the XFP/OTX
|
||
temperature is higher than the
|
||
threshold value written in the
|
||
XFP EEPROM <Condtype> TEMP_HIGH_WARNING_1
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 9 }
|
||
|
||
|
||
pm1001lhrAlmTempLowWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Transceiver Temp Low Warning
|
||
:Warning indicating that the XFP/OTX
|
||
temperature is lower than the threshold
|
||
value written in the XFP/OTX EEPROM
|
||
<Condtype> TEMP_LOW_WARNING_1 <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 8 }
|
||
|
||
|
||
pm1001lhrAlmTxBiasHighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Transceiver Bias High Warning
|
||
:Warning indicating that the XFP/OTX
|
||
transmitter laser bias current
|
||
is higher than the threshold value
|
||
written in the XFP EEPROM <Condtype>
|
||
TX_BIAS_HIGH_WARNING_1 <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 5 }
|
||
|
||
|
||
pm1001lhrAlmTxBiasLowWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Transceiver Bias Low Warning
|
||
:Warning indicating that the XFP/OTX
|
||
transmitter laser bias current
|
||
is lower than the threshold value
|
||
written in the XFP/OTX EEPROM <Condtype>
|
||
TX_BIAS_LOW_WARNING_1 <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 4 }
|
||
|
||
|
||
pm1001lhrAlmTxPowerHighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx Power High Warning
|
||
:Warning indicating that the XFP/OTX
|
||
transmitter transmitter output
|
||
power is higher than the threshold
|
||
value written in the XFP EEPROM
|
||
<Condtype> TX_POWER_HIGH_WARNING_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 3 }
|
||
|
||
|
||
pm1001lhrAlmTxPowerLowWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx Power Low Warning
|
||
:Warning indicating that the XFP/OTX
|
||
transmitter transmitter output
|
||
power is lower than the threshold
|
||
value written in the XFP/OTX EEPROM
|
||
<Condtype> TX_POWER_LOW_WARNING_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1WarningsEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmlineXfp1Alarms articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmlineXfp1AlarmsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmlineXfp1AlarmsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmlineXfp1Alarms
|
||
Article
|
||
"
|
||
::= { pm1001lhrAlmLineCrit 211 }
|
||
|
||
|
||
pm1001lhrAlmlineXfp1AlarmsEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmlineXfp1AlarmsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmlineXfp1Alarms
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmlineXfp1AlarmsIndex }
|
||
::= { pm1001lhrAlmlineXfp1AlarmsTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmlineXfp1AlarmsEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmlineXfp1AlarmsIndex
|
||
INTEGER,
|
||
pm1001lhrAlmApdSupplyFaultPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTecFaultPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmWavelengthUnlockedPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxNrPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxFaultPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmTxCdrNotLockedPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmRxNrPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmRxCdrNotLockedPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmModNrPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmlineXfp1AlarmsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmlineXfp1Alarms
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmApdSupplyFaultPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Rx Photodiode Power Failed
|
||
:This OID indicates a failure on
|
||
the APD power supply <Help> This
|
||
alarm indicates if the APD power
|
||
supply is in fail condition <Condtype>
|
||
APD_SUPPLY_FAULT_1 <Probcause>
|
||
receiverFailure (42) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 17 }
|
||
|
||
|
||
pm1001lhrAlmTecFaultPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx Temp Regul Failed
|
||
:This OID indicates a failure on
|
||
the TEC module <Help> This alarm
|
||
indicates if the TEC of the line
|
||
transceiver is in fail condition
|
||
<Condtype> TEC_FAULT_1 <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 16 }
|
||
|
||
|
||
pm1001lhrAlmWavelengthUnlockedPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx Wavelength Unlocked
|
||
:This OID indicates that the wavelength
|
||
error is exceeding the manufacturer
|
||
tolerance <Help> This alarm indicates
|
||
if the wavelenght of the line transceiver
|
||
is locked <Condtype> WAVELENGTH_UNLOCKED_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 15 }
|
||
|
||
|
||
pm1001lhrAlmTxNrPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx Not Ready :This
|
||
OID indicates a condition has arisen
|
||
leading to invalid data on the
|
||
transmitting side <Help> This
|
||
alarm indicates if the Tx part
|
||
of the line transceiver is ready
|
||
<Condtype> TX_NR_1 <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 9 }
|
||
|
||
|
||
pm1001lhrAlmTxFaultPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx Failure :This
|
||
OID indicates a fault condition
|
||
on the laser detected by the safety
|
||
syste <Help> This alarm indicates
|
||
if the laser of the line transceiver
|
||
is in fail condition <Condtype>
|
||
TX_FAULT_1 <Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 8 }
|
||
|
||
|
||
pm1001lhrAlmTxCdrNotLockedPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Tx CDR Unlocked :This
|
||
OID indicates a loss of lock on
|
||
the transmitting side CDR has been
|
||
detected. <Help> This alarm indicates
|
||
if the Tx CDR is locked in the
|
||
line transceiver <Condtype> TX_CDR_NOT_LOCKED1_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 7 }
|
||
|
||
|
||
pm1001lhrAlmRxNrPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Rx Not Ready :This
|
||
OID indicates that a condition
|
||
has arisen leading to invalid
|
||
data on the receiving side. <Help>
|
||
This alarm indicates if the Rx
|
||
part of the line transceiver is
|
||
ready <Condtype> RX_NR_1 <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 6 }
|
||
|
||
|
||
pm1001lhrAlmRxCdrNotLockedPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Rx CDR Unlocked :This
|
||
OID indicates that a loss of lock
|
||
on the receiving side CDR has been
|
||
detected <Help> This alarm indicates
|
||
if the Rx CDR is locked in the
|
||
line transceiver <Condtype> RX_CDR_NOT_LOCKED1_1
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 4 }
|
||
|
||
|
||
pm1001lhrAlmModNrPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Module Not Ready
|
||
:This OID indicates that the module
|
||
is unable to determine correct
|
||
data. <Help> This alarm indicates
|
||
if the line transceiver is ready
|
||
<Condtype> MOD_NR_1 <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1AlarmsEntry 3 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmlineXfp1SupplyAlarm articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmlineXfp1SupplyAlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmlineXfp1SupplyAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmlineXfp1SupplyAlarm
|
||
Article
|
||
"
|
||
::= { pm1001lhrAlmLineUrg 212 }
|
||
|
||
|
||
pm1001lhrAlmlineXfp1SupplyAlarmEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmlineXfp1SupplyAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmlineXfp1SupplyAlarm
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmlineXfp1SupplyAlarmIndex }
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmlineXfp1SupplyAlarmEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmlineXfp1SupplyAlarmIndex
|
||
INTEGER,
|
||
pm1001lhrAlmVcc5HighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc5LowWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc3HighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc3LowWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc2HighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc2LowWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVee5HighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVee5LowWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc5HighAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc5LowAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc3HighAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc3LowAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc2HighAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVcc2LowAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVee5HighAlarmPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmVee5LowAlarmPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmlineXfp1SupplyAlarmIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmlineXfp1SupplyAlarm
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmVcc5HighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC5 Power Supply High Warning
|
||
:Warning indicating the XFP/OTX
|
||
VCC5 power supply is higher than
|
||
the threshold written in the EEPROM
|
||
<Condtype> VCC5_HIGH_WARNING_1
|
||
<Probcause> powerProblem (36)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 17 }
|
||
|
||
|
||
pm1001lhrAlmVcc5LowWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC5 Power Supply Low Warning
|
||
:Warning indicating the XFP/OTX
|
||
VCC5 power supply is lower than
|
||
the threshold written in the EEPROM
|
||
<Condtype> VCC5_LOW_WARNING_1 <Probcause>
|
||
powerProblem (36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 16 }
|
||
|
||
|
||
pm1001lhrAlmVcc3HighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC3 Power Supply High Warning
|
||
:Warning indicating the XFP/OTX
|
||
VCC3 power supply is higher than
|
||
the threshold written in the EEPROM
|
||
<Condtype> VCC3_HIGH_WARNING_1
|
||
<Probcause> powerProblem (36)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 15 }
|
||
|
||
|
||
pm1001lhrAlmVcc3LowWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC3 Power Supply Low Warning
|
||
:Warning indicating the XFP/OTX
|
||
VCC3 power supply is lower than
|
||
the threshold written in the EEPROM
|
||
<Condtype> VCC3_LOW_WARNING_1 <Probcause>
|
||
powerProblem (36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 14 }
|
||
|
||
|
||
pm1001lhrAlmVcc2HighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC2 Power Supply High Warning
|
||
:Warning indicating the XFP/OTX
|
||
VCC2 power supply is higher than
|
||
the threshold written in the EEPROM
|
||
<Condtype> VCC2_HIGH_WARNING_1
|
||
<Probcause> powerProblem (36)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 13 }
|
||
|
||
|
||
pm1001lhrAlmVcc2LowWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC2 Power Supply Low Warning
|
||
:Warning indicating the XFP/OTX
|
||
VCC2 power supply is lower than
|
||
the threshold written in the EEPROM
|
||
<Condtype> VCC2_LOW_WARNING_1 <Probcause>
|
||
powerProblem (36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 12 }
|
||
|
||
|
||
pm1001lhrAlmVee5HighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VEE5 Power Supply High Warning
|
||
:Warning indicating the XFP/OTX
|
||
VEE5 power supply is higher than
|
||
the threshold written in the EEPROM
|
||
<Condtype> VEE5_HIGH_WARNING_1
|
||
<Probcause> powerProblem (36)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 11 }
|
||
|
||
|
||
pm1001lhrAlmVee5LowWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VEE5 Power Supply Low Warning
|
||
:Warning indicating the XFP/OTX
|
||
VEE5 power supply is lower than
|
||
the threshold written in the EEPROM
|
||
<Condtype> VEE5_LOW_WARNING_1 <Probcause>
|
||
powerProblem (36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 10 }
|
||
|
||
|
||
pm1001lhrAlmVcc5HighAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC5 Power Supply High :Alarm
|
||
indicating the XFP/OTX VCC5 power
|
||
supply is higher than the threshold
|
||
written in the EEPROM <Condtype>
|
||
VCC5_HIGH_ALARM_1 <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 9 }
|
||
|
||
|
||
pm1001lhrAlmVcc5LowAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC5 Power Supply Low :Alarm indicating
|
||
the XFP/OTX VCC5 power supply is
|
||
lower than the threshold written
|
||
in the EEPROM <Condtype> VCC5_LOW_ALARM_1
|
||
<Probcause> powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 8 }
|
||
|
||
|
||
pm1001lhrAlmVcc3HighAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC3 Power Supply High :Alarm
|
||
indicating the XFP/OTX VCC3 power
|
||
supply is higher than the threshold
|
||
written in the EEPROM <Condtype>
|
||
VCC3_HIGH_ALARM_1 <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 7 }
|
||
|
||
|
||
pm1001lhrAlmVcc3LowAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC3 Power Supply Low :Alarm indicating
|
||
the XFP/OTX VCC3 power supply is
|
||
lower than the threshold written
|
||
in the EEPROM <Condtype> VCC3_LOW_ALARM_1
|
||
<Probcause> powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 6 }
|
||
|
||
|
||
pm1001lhrAlmVcc2HighAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC2 Power Supply High :Alarm
|
||
indicating the XFP/OTX VCC2 power
|
||
supply is higher than the threshold
|
||
written in the EEPROM <Condtype>
|
||
VCC2_HIGH_ALARM_1 <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 5 }
|
||
|
||
|
||
pm1001lhrAlmVcc2LowAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VCC2 Power Supply Low :Alarm indicating
|
||
the XFP/OTX VCC2 power supply is
|
||
lower than the threshold written
|
||
in the EEPROM <Condtype> VCC2_LOW_ALARM_1
|
||
<Probcause> powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 4 }
|
||
|
||
|
||
pm1001lhrAlmVee5HighAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VEE5 Power Supply High :Alarm
|
||
indicating the XFP/OTX VEE5 power
|
||
supply is higher than the threshold
|
||
written in the EEPROM <Condtype>
|
||
VEE5_HIGH_ALARM_1 <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 3 }
|
||
|
||
|
||
pm1001lhrAlmVee5LowAlarmPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
VEE5 Power Supply Low :Alarm indicating
|
||
the XFP/OTX VEE5 power supply is
|
||
lower than the threshold written
|
||
in the EEPROM <Condtype> VEE5_LOW_ALARM_1
|
||
<Probcause> powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmlineOtx1TlhAlarms articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmlineOtx1TlhAlarmsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmlineOtx1TlhAlarmsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmlineOtx1TlhAlarms
|
||
Article
|
||
"
|
||
::= { pm1001lhrAlmLineUrg 224 }
|
||
|
||
|
||
pm1001lhrAlmlineOtx1TlhAlarmsEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmlineOtx1TlhAlarmsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmlineOtx1TlhAlarms
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmlineOtx1TlhAlarmsIndex }
|
||
::= { pm1001lhrAlmlineOtx1TlhAlarmsTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmlineOtx1TlhAlarmsEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmlineOtx1TlhAlarmsIndex
|
||
INTEGER,
|
||
pm1001lhrAlmLineLaserTempHighAlaPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineFreqDevHighAlaPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineAgingHighAlaPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineModulatorAgingHighAlaPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmlineOtx1TlhAlarmsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmlineOtx1TlhAlarms
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmLineLaserTempHighAlaPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Laser Temp. High Alarm :Alarm
|
||
indicating the Line OTX TLH laser
|
||
temperature is higher than the
|
||
threshold written in the EEPROM
|
||
<Condtype> LINE_LASER_TEMP_HIGH_ALA_1
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 15 }
|
||
|
||
|
||
pm1001lhrAlmLineFreqDevHighAlaPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Freq. Deviation High Alarm
|
||
:Alarm indicating the Line OTX
|
||
TLH frequency deviation is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> LINE_FREQ_DEV_HIGH_ALA_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 13 }
|
||
|
||
|
||
pm1001lhrAlmLineAgingHighAlaPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line OTX TLH Aging High Alarm
|
||
:Alarm indicating the Line OTX
|
||
TLH aging is higher than the threshold
|
||
written in the EEPROM <Condtype>
|
||
LINE_AGING_HIGH_ALA_1 <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 7 }
|
||
|
||
|
||
pm1001lhrAlmLineModulatorAgingHighAlaPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Modulator Aging High Alarm
|
||
:Alarm indicating the Line OTX
|
||
TLH modulator aging is higher
|
||
than the threshold written in
|
||
the EEPROM <Condtype> LINE_MODULATOR_AGING_HIGH_ALA_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 6 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrAlmlineOtx1TlhWarnings articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrAlmlineOtx1TlhWarningsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrAlmlineOtx1TlhWarningsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrAlmlineOtx1TlhWarnings
|
||
Article
|
||
"
|
||
::= { pm1001lhrAlmLineNurg 225 }
|
||
|
||
|
||
pm1001lhrAlmlineOtx1TlhWarningsEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAlmlineOtx1TlhWarningsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrAlmlineOtx1TlhWarnings
|
||
table
|
||
"
|
||
INDEX { pm1001lhrAlmlineOtx1TlhWarningsIndex }
|
||
::= { pm1001lhrAlmlineOtx1TlhWarningsTable 1 }
|
||
|
||
|
||
Pm1001lhrAlmlineOtx1TlhWarningsEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrAlmlineOtx1TlhWarningsIndex
|
||
INTEGER,
|
||
pm1001lhrAlmLineLaserTempHighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineFreqDevHighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineAgingHighWarningPortn
|
||
EkiOnOff,
|
||
pm1001lhrAlmLineModulatorAgingHighWarningPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrAlmlineOtx1TlhWarningsIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrAlmlineOtx1TlhWarnings
|
||
table
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 1 }
|
||
|
||
|
||
pm1001lhrAlmLineLaserTempHighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Laser Temp. High Warning
|
||
:Warning indicating the Line OTX
|
||
TLH laser temperature is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> LINE_LASER_TEMP_HIGH_WARNING_1
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 15 }
|
||
|
||
|
||
pm1001lhrAlmLineFreqDevHighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Freq. Deviation High Warning
|
||
:Warning indicating the Line OTX
|
||
TLH frequency deviation is higher
|
||
than the threshold written in the
|
||
EEPROM <Condtype> LINE_FREQ_DEV_HIGH_WARNING_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 13 }
|
||
|
||
|
||
pm1001lhrAlmLineAgingHighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line OTX TLH Aging High Warning
|
||
:Warning indicating the Line OTX
|
||
TLH aging is higher than the threshold
|
||
written in the EEPROM <Condtype>
|
||
LINE_AGING_HIGH_WARNING_1 <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 7 }
|
||
|
||
|
||
pm1001lhrAlmLineModulatorAgingHighWarningPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Modulator Aging High Warning
|
||
:Warning indicating the Line OTX
|
||
TLH modulator aging is higher than
|
||
the threshold written in the EEPROM
|
||
<Condtype> LINE_MODULATOR_AGING_HIGH_WARNING_1
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 6 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONTROLS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the confMgnt1 article
|
||
--- *****************************************************
|
||
pm1001lhrCtrlconfMgnt1 OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 1 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrCtrlConf2Clear1 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Clear Configuration Tables :This
|
||
OID clears the configuration tables
|
||
from configuration2 in the flash.
|
||
<Help> This control restores
|
||
the default configuration of the
|
||
module
|
||
"
|
||
::= { pm1001lhrCtrlconfMgnt1 14 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlConf2Flash1 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Write Configuration Tables :This
|
||
OID saves the current configuration
|
||
of the PM as configuration2 in
|
||
the flash. <Help> This control
|
||
saves the customer configuration
|
||
on the module
|
||
"
|
||
::= { pm1001lhrCtrlconfMgnt1 10 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlConf2Load1 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables Set
|
||
Nb 2 :When set this OID enables
|
||
loading from flash configuration2
|
||
into the PM.
|
||
"
|
||
::= { pm1001lhrCtrlconfMgnt1 2 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlConf1Load1 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables Set
|
||
Nb 1 :When set this OID enables
|
||
loading from flash configuration1
|
||
into the PM.
|
||
"
|
||
::= { pm1001lhrCtrlconfMgnt1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth4 article
|
||
--- *****************************************************
|
||
pm1001lhrCtrlsynth4 OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 4 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrCtrlCorrelatOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Disable Alarm Correlation :This
|
||
OID disables the alarm correlation
|
||
in the PM.
|
||
"
|
||
::= { pm1001lhrCtrlsynth4 2 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlCorrelatOn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Enable Alarm Correlation :This
|
||
OID enables the alarm correlation
|
||
in the PM.
|
||
"
|
||
::= { pm1001lhrCtrlsynth4 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swMgnt article
|
||
--- *****************************************************
|
||
pm1001lhrCtrlswMgnt OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 5 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrCtrlLoadSwBank2 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Set Software Nb 2 As Active :This
|
||
OID, when set, loads the SW from
|
||
bank2 into the PM. It must be followed
|
||
by a reset. <Help> This controls
|
||
selects the second SW bank as the
|
||
active bank for the next module
|
||
reset
|
||
"
|
||
::= { pm1001lhrCtrlswMgnt 6 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlLoadSwBank1 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Set Software Nb 1 As Active :This
|
||
OID, when set, loads the SW from
|
||
bank1 into the PM. It must be followed
|
||
by a reset. <Help> This controls
|
||
selects the first SW bank as the
|
||
active bank for the next module
|
||
reset
|
||
"
|
||
::= { pm1001lhrCtrlswMgnt 5 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlWarmReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Warm Reset :This OID, when
|
||
set, causes a warm reset of the
|
||
PM. This reset is not traffic affecting,
|
||
and the configuration of PM remains
|
||
unchanged. <Help> This control
|
||
initiates a warm reset of the module.
|
||
"
|
||
::= { pm1001lhrCtrlswMgnt 3 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlColdReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Cold Reset :This OID, when
|
||
set, causes a cold reset of the
|
||
PM. This reset is traffic affecting,
|
||
and the configuration of PM is
|
||
reloaded on start-up. <Help>
|
||
This control initiates a cold
|
||
reset of the module.
|
||
"
|
||
::= { pm1001lhrCtrlswMgnt 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the gwMgnt article
|
||
--- *****************************************************
|
||
pm1001lhrCtrlgwMgnt OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 6 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrCtrlLoadGwBank4 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Set Gateware Nb 4 As Active :This
|
||
OID, when set, loads the GW from
|
||
bank4 (Flash) into the PM. It is
|
||
followed by an automatic gateware
|
||
cold reset.
|
||
"
|
||
::= { pm1001lhrCtrlgwMgnt 8 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlLoadGwBank3 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Set Gateware Nb 3 As Active :This
|
||
OID, when set, loads the GW from
|
||
bank3 (Flash) into the PM. It is
|
||
followed by an automatic gateware
|
||
cold reset. <Help> This controls
|
||
initiates a cold reset of the module
|
||
and select the third GW bank as
|
||
the active bank
|
||
"
|
||
::= { pm1001lhrCtrlgwMgnt 7 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlLoadGwBank2 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Set Gateware Nb 2 As Active :This
|
||
OID, when set, loads the GW from
|
||
bank2 (Flash) into the PM. It is
|
||
followed by an automatic gateware
|
||
cold reset.
|
||
"
|
||
::= { pm1001lhrCtrlgwMgnt 6 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlLoadGwBank1 OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Set Gateware Nb 1 As Active :This
|
||
OID, when set, loads the GW from
|
||
bank1 (Flash) into the PM. It is
|
||
followed by an automatic gateware
|
||
cold reset. <Help> This controls
|
||
initiates a cold reset of the module
|
||
and select the first GW bank as
|
||
the active bank
|
||
"
|
||
::= { pm1001lhrCtrlgwMgnt 5 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlCurrentGwReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Active Gateware Reset :This OID,
|
||
when set, resets the active gateware.
|
||
It is traffic affecting.
|
||
"
|
||
::= { pm1001lhrCtrlgwMgnt 1 }
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrlaccessLoop articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrlaccessLoopTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrlaccessLoopEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrlaccessLoop
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlClient 16 }
|
||
|
||
|
||
pm1001lhrCtrlaccessLoopEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrlaccessLoopEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrlaccessLoop
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrlaccessLoopIndex }
|
||
::= { pm1001lhrCtrlaccessLoopTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrlaccessLoopEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrlaccessLoopIndex
|
||
INTEGER,
|
||
pm1001lhrCtrlaccessLoopPortn
|
||
EkiState
|
||
}
|
||
|
||
|
||
pm1001lhrCtrlaccessLoopIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrlaccessLoop
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrlaccessLoopEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrlaccessLoopPortn OBJECT-TYPE
|
||
SYNTAX EkiState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Client Facility Loopback :This
|
||
OID operates a Client Facility
|
||
Loopback, looping client input
|
||
signal on the client output port.
|
||
The loop is located on the client
|
||
transceiver <Help> This maintenance
|
||
parameter operates a Client Facility
|
||
Loopback, looping client input
|
||
signal on the client output port.
|
||
The loop is located on the client
|
||
transceiver
|
||
"
|
||
::= { pm1001lhrCtrlaccessLoopEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrlclientAccessTermLoop articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrlclientAccessTermLoopTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrlclientAccessTermLoopEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrlclientAccessTermLoop
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlClient 26 }
|
||
|
||
|
||
pm1001lhrCtrlclientAccessTermLoopEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrlclientAccessTermLoopEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrlclientAccessTermLoop
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrlclientAccessTermLoopIndex }
|
||
::= { pm1001lhrCtrlclientAccessTermLoopTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrlclientAccessTermLoopEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrlclientAccessTermLoopIndex
|
||
INTEGER,
|
||
pm1001lhrCtrlclientAccessTermLoopPortn
|
||
EkiState
|
||
}
|
||
|
||
|
||
pm1001lhrCtrlclientAccessTermLoopIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrlclientAccessTermLoop
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrlclientAccessTermLoopEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrlclientAccessTermLoopPortn OBJECT-TYPE
|
||
SYNTAX EkiState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Client Terminal Loopback :This
|
||
OID operates a Client Terminal
|
||
Loopback, looping client input
|
||
signal on the client output port.
|
||
The loop is located on the line
|
||
transceiver <Help> This maintenance
|
||
parameter operates a Client Terminal
|
||
Loopback, looping client input
|
||
signal on the client output port.
|
||
The loop is located on the line
|
||
transceiver
|
||
"
|
||
::= { pm1001lhrCtrlclientAccessTermLoopEntry 2 }
|
||
|
||
|
||
pm1001lhrCtrlprotocol OBJECT-TYPE
|
||
SYNTAX EkiProtocol
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Client Protocol :This OID sets
|
||
the protocol on the PM
|
||
"
|
||
::= { pm1001lhrCtrlLine 52 }
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrlfecDisable articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrlfecDisableTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrlfecDisableEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrlfecDisable
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 69 }
|
||
|
||
|
||
pm1001lhrCtrlfecDisableEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrlfecDisableEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrlfecDisable
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrlfecDisableIndex }
|
||
::= { pm1001lhrCtrlfecDisableTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrlfecDisableEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrlfecDisableIndex
|
||
INTEGER,
|
||
pm1001lhrCtrlfecDisablePortn
|
||
EkiState
|
||
}
|
||
|
||
|
||
pm1001lhrCtrlfecDisableIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrlfecDisable
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrlfecDisableEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrlfecDisablePortn OBJECT-TYPE
|
||
SYNTAX EkiState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Forward Error Correction Inhibition
|
||
:This OID, when set, inhibits the
|
||
Forward Error Correction feature
|
||
on the line input <Help> This
|
||
control disables the Forward Error
|
||
Correction on the line input signal.
|
||
"
|
||
::= { pm1001lhrCtrlfecDisableEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrllineOosMode articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrllineOosModeTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrllineOosModeEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrllineOosMode
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 74 }
|
||
|
||
|
||
pm1001lhrCtrllineOosModeEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrllineOosModeEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrllineOosMode
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrllineOosModeIndex }
|
||
::= { pm1001lhrCtrllineOosModeTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrllineOosModeEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrllineOosModeIndex
|
||
INTEGER,
|
||
pm1001lhrCtrllineOosModePortn
|
||
EkiState
|
||
}
|
||
|
||
|
||
pm1001lhrCtrllineOosModeIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrllineOosMode
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrllineOosModeEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrllineOosModePortn OBJECT-TYPE
|
||
SYNTAX EkiState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port Out Of Service :This
|
||
OID sets the line port Out Of Service
|
||
"
|
||
::= { pm1001lhrCtrllineOosModeEntry 2 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the ledTest article
|
||
--- *****************************************************
|
||
pm1001lhrCtrlledTest OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 192 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrCtrlLedOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Leds Off :This OID switches off
|
||
all the Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to OFF
|
||
"
|
||
::= { pm1001lhrCtrlledTest 3 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlRedLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Red Leds Test :This OID switches
|
||
on all the red Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to red
|
||
"
|
||
::= { pm1001lhrCtrlledTest 2 }
|
||
|
||
|
||
|
||
pm1001lhrCtrlGreenLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Green Leds Test :This OID switches
|
||
on all the green Leds as a test
|
||
feature. <Help> This control
|
||
initiates a test leds turning
|
||
all the LEDs to green
|
||
"
|
||
::= { pm1001lhrCtrlledTest 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the moduleOosMode article
|
||
--- *****************************************************
|
||
pm1001lhrCtrlmoduleOosMode OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 193 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrCtrlModuleOosMode OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Out Of Service :This OID sets
|
||
the PM1008 Out Of Service <Help>
|
||
This control defines the service
|
||
state of the complete module
|
||
"
|
||
::= { pm1001lhrCtrlmoduleOosMode 1 }
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrlxfpOnoff articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrlxfpOnoffTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrlxfpOnoffEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrlxfpOnoff
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 208 }
|
||
|
||
|
||
pm1001lhrCtrlxfpOnoffEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrlxfpOnoffEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrlxfpOnoff
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrlxfpOnoffIndex }
|
||
::= { pm1001lhrCtrlxfpOnoffTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrlxfpOnoffEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrlxfpOnoffIndex
|
||
INTEGER,
|
||
pm1001lhrCtrlxfpOnoffPortn
|
||
EkiState
|
||
}
|
||
|
||
|
||
pm1001lhrCtrlxfpOnoffIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrlxfpOnoff
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrlxfpOnoffEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrlxfpOnoffPortn OBJECT-TYPE
|
||
SYNTAX EkiState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Laser Shutdown :This
|
||
OID switches off the XFP or the
|
||
OTX <Help> This control defines
|
||
the laser state of the line transceiver
|
||
"
|
||
::= { pm1001lhrCtrlxfpOnoffEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrlxfpLineLoop articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrlxfpLineLoopTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrlxfpLineLoopEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrlxfpLineLoop
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 209 }
|
||
|
||
|
||
pm1001lhrCtrlxfpLineLoopEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrlxfpLineLoopEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrlxfpLineLoop
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrlxfpLineLoopIndex }
|
||
::= { pm1001lhrCtrlxfpLineLoopTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrlxfpLineLoopEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrlxfpLineLoopIndex
|
||
INTEGER,
|
||
pm1001lhrCtrlxfpLineLoopPortn
|
||
EkiState
|
||
}
|
||
|
||
|
||
pm1001lhrCtrlxfpLineLoopIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrlxfpLineLoop
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrlxfpLineLoopEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrlxfpLineLoopPortn OBJECT-TYPE
|
||
SYNTAX EkiState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Facility Loopback :This OID
|
||
operates a Line Facility Loopback,
|
||
looping line input signal on the
|
||
line output port. The loop is located
|
||
on the line transceiver. If the
|
||
Line signal carries DCC, the management
|
||
network is impacted <Help> This
|
||
maintenance parameter operates
|
||
a Line Facility Loopback, looping
|
||
line input signal on the line output
|
||
port. The loop is located on the
|
||
line transceiver. If the Line signal
|
||
carries DCC, the management network
|
||
is impacted
|
||
"
|
||
::= { pm1001lhrCtrlxfpLineLoopEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrlxfpXfiLoop articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrlxfpXfiLoopTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrlxfpXfiLoopEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrlxfpXfiLoop
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 210 }
|
||
|
||
|
||
pm1001lhrCtrlxfpXfiLoopEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrlxfpXfiLoopEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrlxfpXfiLoop
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrlxfpXfiLoopIndex }
|
||
::= { pm1001lhrCtrlxfpXfiLoopTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrlxfpXfiLoopEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrlxfpXfiLoopIndex
|
||
INTEGER,
|
||
pm1001lhrCtrlxfpXfiLoopPortn
|
||
EkiState
|
||
}
|
||
|
||
|
||
pm1001lhrCtrlxfpXfiLoopIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrlxfpXfiLoop
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrlxfpXfiLoopEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrlxfpXfiLoopPortn OBJECT-TYPE
|
||
SYNTAX EkiState
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Terminal Loopback :This OID
|
||
operates a Line Terminal Loopback,
|
||
looping line input signal on the
|
||
line output port. The loop is located
|
||
on all client transceivers <Help>
|
||
This maintenance parameter operates
|
||
a Line Terminal Loopback, looping
|
||
line input signal on the line output
|
||
port. The loop is located on all
|
||
client transceivers.
|
||
"
|
||
::= { pm1001lhrCtrlxfpXfiLoopEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrllineTunableChannel articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrllineTunableChannelTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrllineTunableChannelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrllineTunableChannel
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 212 }
|
||
|
||
|
||
pm1001lhrCtrllineTunableChannelEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrllineTunableChannelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrllineTunableChannel
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrllineTunableChannelIndex }
|
||
::= { pm1001lhrCtrllineTunableChannelTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrllineTunableChannelEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrllineTunableChannelIndex
|
||
INTEGER,
|
||
pm1001lhrCtrllineTunableChannelPortn
|
||
Pm1001lhrOtxChannel
|
||
}
|
||
|
||
|
||
pm1001lhrCtrllineTunableChannelIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrllineTunableChannel
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrllineTunableChannelEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrllineTunableChannelPortn OBJECT-TYPE
|
||
SYNTAX Pm1001lhrOtxChannel
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
ITU Channel :This OID selects
|
||
the ITU channel of the Line OTX
|
||
TLH Laser <Help> This control
|
||
defines the ITU channel of the
|
||
Line OTX TLH Laser
|
||
"
|
||
::= { pm1001lhrCtrllineTunableChannelEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrllinePhotodiodeMode articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrllinePhotodiodeModeTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrllinePhotodiodeModeEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrllinePhotodiodeMode
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 213 }
|
||
|
||
|
||
pm1001lhrCtrllinePhotodiodeModeEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrllinePhotodiodeModeEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrllinePhotodiodeMode
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrllinePhotodiodeModeIndex }
|
||
::= { pm1001lhrCtrllinePhotodiodeModeTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrllinePhotodiodeModeEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrllinePhotodiodeModeIndex
|
||
INTEGER,
|
||
pm1001lhrCtrllinePhotodiodeModePortn
|
||
Pm1001lhrOtxMode
|
||
}
|
||
|
||
|
||
pm1001lhrCtrllinePhotodiodeModeIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrllinePhotodiodeMode
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrllinePhotodiodeModeEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrllinePhotodiodeModePortn OBJECT-TYPE
|
||
SYNTAX Pm1001lhrOtxMode
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OTX TLH Rx Sens. Mode :This OID
|
||
defines the Rx sensiblity mode
|
||
of the Line OTX TLH <Help>
|
||
This control defines the receiver
|
||
sensibility mode of the Line OTX
|
||
TLH Laser (OTX60, OTX80 or Custom)
|
||
"
|
||
::= { pm1001lhrCtrllinePhotodiodeModeEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrllinePhotodiodeValue articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrllinePhotodiodeValueTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrllinePhotodiodeValueEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrllinePhotodiodeValue
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 214 }
|
||
|
||
|
||
pm1001lhrCtrllinePhotodiodeValueEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrllinePhotodiodeValueEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrllinePhotodiodeValue
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrllinePhotodiodeValueIndex }
|
||
::= { pm1001lhrCtrllinePhotodiodeValueTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrllinePhotodiodeValueEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrllinePhotodiodeValueIndex
|
||
INTEGER,
|
||
pm1001lhrCtrllinePhotodiodeValuePortn
|
||
Pm1001lhrAdjustValue
|
||
}
|
||
|
||
|
||
pm1001lhrCtrllinePhotodiodeValueIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrllinePhotodiodeValue
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrllinePhotodiodeValueEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrllinePhotodiodeValuePortn OBJECT-TYPE
|
||
SYNTAX Pm1001lhrAdjustValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
OTX TLH Rx Sensibility :This OID
|
||
sets the Rx sensibility of the
|
||
Line OTX TLH (custom mode only)
|
||
<Help> This control defines
|
||
the receiver sensibility value
|
||
(only in Custom mode) of the Line
|
||
OTX TLH Laser
|
||
"
|
||
::= { pm1001lhrCtrllinePhotodiodeValueEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCtrllinePowerLaser articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCtrllinePowerLaserTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCtrllinePowerLaserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCtrllinePowerLaser
|
||
Article
|
||
"
|
||
::= { pm1001lhrCtrlLine 215 }
|
||
|
||
|
||
pm1001lhrCtrllinePowerLaserEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCtrllinePowerLaserEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCtrllinePowerLaser
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCtrllinePowerLaserIndex }
|
||
::= { pm1001lhrCtrllinePowerLaserTable 1 }
|
||
|
||
|
||
Pm1001lhrCtrllinePowerLaserEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCtrllinePowerLaserIndex
|
||
INTEGER,
|
||
pm1001lhrCtrllinePowerLaserPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrCtrllinePowerLaserIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCtrllinePowerLaser
|
||
table
|
||
"
|
||
::= { pm1001lhrCtrllinePowerLaserEntry 1 }
|
||
|
||
|
||
pm1001lhrCtrllinePowerLaserPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Laser Output Power [3-5]
|
||
:This OID sets the output power
|
||
value on the laser of the Line
|
||
OTX TLH (AV=Power*10+158) (Unit
|
||
= dBm) <Help> This control defines
|
||
the start-up output power of the
|
||
Line OTX TLH
|
||
"
|
||
::= { pm1001lhrCtrllinePowerLaserEntry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- COUNTERS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCntdfrmB1ErrCnt articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCntdfrmB1ErrCntTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCntdfrmB1ErrCntEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCntdfrmB1ErrCnt
|
||
Article
|
||
"
|
||
::= { pm1001lhrCntLine 152 }
|
||
|
||
|
||
pm1001lhrCntdfrmB1ErrCntEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCntdfrmB1ErrCntEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCntdfrmB1ErrCnt
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCntdfrmB1ErrCntIndex }
|
||
::= { pm1001lhrCntdfrmB1ErrCntTable 1 }
|
||
|
||
|
||
Pm1001lhrCntdfrmB1ErrCntEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCntdfrmB1ErrCntIndex
|
||
INTEGER,
|
||
pm1001lhrCntdfrmB1ErrCntValuePortn
|
||
Counter32,
|
||
pm1001lhrCntdfrmB1ErrCntErrorPortn
|
||
EkiOnOff,
|
||
pm1001lhrCntdfrmB1ErrCntOverloadPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrCntdfrmB1ErrCntIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCntdfrmB1ErrCnt
|
||
table
|
||
"
|
||
::= { pm1001lhrCntdfrmB1ErrCntEntry 1 }
|
||
|
||
|
||
pm1001lhrCntdfrmB1ErrCntValuePortn OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Input SM-BIP8 Errors :This
|
||
counter is incremented each time
|
||
a B1 error is detected on the Deframer
|
||
input stream. <Help> This counter
|
||
gives the number of B1 errors on
|
||
the line port
|
||
"
|
||
::= { pm1001lhrCntdfrmB1ErrCntEntry 2 }
|
||
|
||
|
||
pm1001lhrCntdfrmB1ErrCntErrorPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Counter Error :This OID when
|
||
set indicates the B1 error counter
|
||
value is invalid on Port
|
||
"
|
||
::= { pm1001lhrCntdfrmB1ErrCntEntry 3 }
|
||
|
||
|
||
pm1001lhrCntdfrmB1ErrCntOverloadPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Counter Overload :This OID
|
||
when set indicates a B1 error counter
|
||
overload on Port
|
||
"
|
||
::= { pm1001lhrCntdfrmB1ErrCntEntry 4 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCntdfrmTimCnt articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCntdfrmTimCntTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCntdfrmTimCntEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCntdfrmTimCnt
|
||
Article
|
||
"
|
||
::= { pm1001lhrCntLine 153 }
|
||
|
||
|
||
pm1001lhrCntdfrmTimCntEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCntdfrmTimCntEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCntdfrmTimCnt
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCntdfrmTimCntIndex }
|
||
::= { pm1001lhrCntdfrmTimCntTable 1 }
|
||
|
||
|
||
Pm1001lhrCntdfrmTimCntEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCntdfrmTimCntIndex
|
||
INTEGER,
|
||
pm1001lhrCntdfrmTimCntValuePortn
|
||
Counter32,
|
||
pm1001lhrCntdfrmTimCntErrorPortn
|
||
EkiOnOff,
|
||
pm1001lhrCntdfrmTimCntOverloadPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrCntdfrmTimCntIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCntdfrmTimCnt
|
||
table
|
||
"
|
||
::= { pm1001lhrCntdfrmTimCntEntry 1 }
|
||
|
||
|
||
pm1001lhrCntdfrmTimCntValuePortn OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Timer Counter :This is the
|
||
timing counter dedicated to the
|
||
downstream deframer counters. It
|
||
is incremented every 125 us.
|
||
"
|
||
::= { pm1001lhrCntdfrmTimCntEntry 2 }
|
||
|
||
|
||
pm1001lhrCntdfrmTimCntErrorPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Counter Error :This OID when
|
||
set indicates the deframer timer
|
||
counter value is invalid on Port
|
||
"
|
||
::= { pm1001lhrCntdfrmTimCntEntry 3 }
|
||
|
||
|
||
pm1001lhrCntdfrmTimCntOverloadPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Counter Overload :This OID
|
||
when set indicates a deframer timer
|
||
counter overload on Port
|
||
"
|
||
::= { pm1001lhrCntdfrmTimCntEntry 4 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrCntdfrmPrimLineErrCnt articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrCntdfrmPrimLineErrCntTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCntdfrmPrimLineErrCntEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrCntdfrmPrimLineErrCnt
|
||
Article
|
||
"
|
||
::= { pm1001lhrCntLine 154 }
|
||
|
||
|
||
pm1001lhrCntdfrmPrimLineErrCntEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCntdfrmPrimLineErrCntEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrCntdfrmPrimLineErrCnt
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCntdfrmPrimLineErrCntIndex }
|
||
::= { pm1001lhrCntdfrmPrimLineErrCntTable 1 }
|
||
|
||
|
||
Pm1001lhrCntdfrmPrimLineErrCntEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCntdfrmPrimLineErrCntIndex
|
||
INTEGER,
|
||
pm1001lhrCntdfrmPrimLineErrCntValuePortn
|
||
Counter32,
|
||
pm1001lhrCntdfrmPrimLineErrCntErrorPortn
|
||
EkiOnOff,
|
||
pm1001lhrCntdfrmPrimLineErrCntOverloadPortn
|
||
EkiOnOff
|
||
}
|
||
|
||
|
||
pm1001lhrCntdfrmPrimLineErrCntIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrCntdfrmPrimLineErrCnt
|
||
table
|
||
"
|
||
::= { pm1001lhrCntdfrmPrimLineErrCntEntry 1 }
|
||
|
||
|
||
pm1001lhrCntdfrmPrimLineErrCntValuePortn OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Input FEC Corrected Errors
|
||
:This counter is incremented each
|
||
time the FEC is correcting an error
|
||
on the line input stream. <Help>
|
||
This counter gives the number
|
||
of errors corrected by the FEC
|
||
on the line port
|
||
"
|
||
::= { pm1001lhrCntdfrmPrimLineErrCntEntry 2 }
|
||
|
||
|
||
pm1001lhrCntdfrmPrimLineErrCntErrorPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
FEC Counter Error :This bit when
|
||
set indicates the FEC corrected
|
||
errors counter value is invalid
|
||
on Line
|
||
"
|
||
::= { pm1001lhrCntdfrmPrimLineErrCntEntry 3 }
|
||
|
||
|
||
pm1001lhrCntdfrmPrimLineErrCntOverloadPortn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
FEC Counter Overload :This bit
|
||
when set indicates a FEC corrected
|
||
errors counter overload on Line
|
||
"
|
||
::= { pm1001lhrCntdfrmPrimLineErrCntEntry 4 }
|
||
|
||
|
||
pm1001lhrCntCountersReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Counters Reset:This OID resets and restarts all the counters"
|
||
::= { pm1001lhrcounters 259 }
|
||
|
||
pm1001lhrCntCountersStop OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Counters stop:This OID stops all the counters"
|
||
::= { pm1001lhrcounters 260 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- MEASURES
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
pm1001lhrMesrsynth0 OBJECT-TYPE
|
||
SYNTAX EkiMeasureType
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Not Used :This OID gives the unit
|
||
used on AUX1 measurement of XFP#1
|
||
(Unit = )
|
||
"
|
||
::= { pm1001lhrMesrOther 0 }
|
||
|
||
|
||
|
||
pm1001lhrMesrsynth1 OBJECT-TYPE
|
||
SYNTAX EkiMeasureType
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Not Used :This OID gives the unit
|
||
used on AUX2 measurement of XFP#1
|
||
(Unit = )
|
||
"
|
||
::= { pm1001lhrMesrOther 1 }
|
||
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrxfp1LxModTempMeas articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrxfp1LxModTempMeasTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LxModTempMeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrxfp1LxModTempMeas
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 208 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LxModTempMeasEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrxfp1LxModTempMeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrxfp1LxModTempMeas
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrxfp1LxModTempMeasIndex }
|
||
::= { pm1001lhrMesrxfp1LxModTempMeasTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrxfp1LxModTempMeasEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrxfp1LxModTempMeasIndex
|
||
INTEGER,
|
||
pm1001lhrMesrxfp1LxModTempMeasPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrxfp1LxModTempMeasIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrxfp1LxModTempMeas
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrxfp1LxModTempMeasEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LxModTempMeasPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Module Temperature
|
||
:This OID gives the temperature
|
||
of the XFP or OTX plugged in line#n,
|
||
read from the DDM (Digital Diagnostic
|
||
Monitoring) (Temperature = AV/256)
|
||
(Unit = C) <Help> This measure
|
||
gives the temperature of the line
|
||
transceiver
|
||
"
|
||
::= { pm1001lhrMesrxfp1LxModTempMeasEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrxfp1Reserved articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrxfp1ReservedTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1ReservedEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrxfp1Reserved
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 209 }
|
||
|
||
|
||
pm1001lhrMesrxfp1ReservedEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrxfp1ReservedEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrxfp1Reserved
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrxfp1ReservedIndex }
|
||
::= { pm1001lhrMesrxfp1ReservedTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrxfp1ReservedEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrxfp1ReservedIndex
|
||
INTEGER,
|
||
pm1001lhrMesrxfp1ReservedPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrxfp1ReservedIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrxfp1Reserved
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrxfp1ReservedEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrxfp1ReservedPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Not Used :Reserved
|
||
"
|
||
::= { pm1001lhrMesrxfp1ReservedEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrxfp1LoBiasCurrentMeas articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrxfp1LoBiasCurrentMeasTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LoBiasCurrentMeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrxfp1LoBiasCurrentMeas
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 210 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LoBiasCurrentMeasEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrxfp1LoBiasCurrentMeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrxfp1LoBiasCurrentMeas
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrxfp1LoBiasCurrentMeasIndex }
|
||
::= { pm1001lhrMesrxfp1LoBiasCurrentMeasTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrxfp1LoBiasCurrentMeasEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrxfp1LoBiasCurrentMeasIndex
|
||
INTEGER,
|
||
pm1001lhrMesrxfp1LoBiasCurrentMeasPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrxfp1LoBiasCurrentMeasIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrxfp1LoBiasCurrentMeas
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrxfp1LoBiasCurrentMeasEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LoBiasCurrentMeasPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Module Laser Bias
|
||
:This OID gives the bias value
|
||
of the XFP or OTX plugged in line
|
||
#n, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Bias =
|
||
AV/500) (Unit = mA) <Help> This
|
||
measure gives the bias of the line
|
||
transceiver
|
||
"
|
||
::= { pm1001lhrMesrxfp1LoBiasCurrentMeasEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrxfp1LoTxPowerMeas articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrxfp1LoTxPowerMeasTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LoTxPowerMeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrxfp1LoTxPowerMeas
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 211 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LoTxPowerMeasEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrxfp1LoTxPowerMeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrxfp1LoTxPowerMeas
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrxfp1LoTxPowerMeasIndex }
|
||
::= { pm1001lhrMesrxfp1LoTxPowerMeasTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrxfp1LoTxPowerMeasEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrxfp1LoTxPowerMeasIndex
|
||
INTEGER,
|
||
pm1001lhrMesrxfp1LoTxPowerMeasPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrxfp1LoTxPowerMeasIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrxfp1LoTxPowerMeas
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrxfp1LoTxPowerMeasEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LoTxPowerMeasPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Module Tx Power :This
|
||
OID gives the transmit power value
|
||
of the XFP or OTX plugged in line
|
||
#n, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Power
|
||
= 10*log(AV)-40) (Unit = dBm)
|
||
<Help> This measure gives the
|
||
Tx optical power of the line transceiver
|
||
"
|
||
::= { pm1001lhrMesrxfp1LoTxPowerMeasEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrxfp1LiRxPowerMeas articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrxfp1LiRxPowerMeasTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LiRxPowerMeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrxfp1LiRxPowerMeas
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 212 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LiRxPowerMeasEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrxfp1LiRxPowerMeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrxfp1LiRxPowerMeas
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrxfp1LiRxPowerMeasIndex }
|
||
::= { pm1001lhrMesrxfp1LiRxPowerMeasTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrxfp1LiRxPowerMeasEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrxfp1LiRxPowerMeasIndex
|
||
INTEGER,
|
||
pm1001lhrMesrxfp1LiRxPowerMeasPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrxfp1LiRxPowerMeasIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrxfp1LiRxPowerMeas
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrxfp1LiRxPowerMeasEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LiRxPowerMeasPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Module Rx Power :This
|
||
OID gives the receive power value
|
||
of the XFP or OTX plugged in line
|
||
#n, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Power
|
||
= 10*log(AV)-40) (Unit = dBm)
|
||
<Help> This measure gives the
|
||
Rx optical power of the line transceiver
|
||
"
|
||
::= { pm1001lhrMesrxfp1LiRxPowerMeasEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrxfp1LxAux1Meas articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrxfp1LxAux1MeasTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LxAux1MeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrxfp1LxAux1Meas
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 213 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LxAux1MeasEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrxfp1LxAux1MeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrxfp1LxAux1Meas
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrxfp1LxAux1MeasIndex }
|
||
::= { pm1001lhrMesrxfp1LxAux1MeasTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrxfp1LxAux1MeasEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrxfp1LxAux1MeasIndex
|
||
INTEGER,
|
||
pm1001lhrMesrxfp1LxAux1MeasPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrxfp1LxAux1MeasIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrxfp1LxAux1Meas
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrxfp1LxAux1MeasEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LxAux1MeasPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Not Used :This OID gives the receive
|
||
power value read in the DDM (Digital
|
||
Diagnostic Monitoring) of the XFP
|
||
or OTX plugged in line #n (Unit
|
||
= ?)
|
||
"
|
||
::= { pm1001lhrMesrxfp1LxAux1MeasEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrxfp1LxAux2Meas articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrxfp1LxAux2MeasTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LxAux2MeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrxfp1LxAux2Meas
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 214 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LxAux2MeasEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrxfp1LxAux2MeasEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrxfp1LxAux2Meas
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrxfp1LxAux2MeasIndex }
|
||
::= { pm1001lhrMesrxfp1LxAux2MeasTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrxfp1LxAux2MeasEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrxfp1LxAux2MeasIndex
|
||
INTEGER,
|
||
pm1001lhrMesrxfp1LxAux2MeasPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrxfp1LxAux2MeasIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrxfp1LxAux2Meas
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrxfp1LxAux2MeasEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrxfp1LxAux2MeasPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Not Used :This OID gives the receive
|
||
power value read in the DDM (Digital
|
||
Diagnostic Monitoring) of the XFP
|
||
or OTX plugged in line #n (Unit
|
||
= ?)
|
||
"
|
||
::= { pm1001lhrMesrxfp1LxAux2MeasEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrotx1Aging articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrotx1AgingTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrotx1AgingEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrotx1Aging
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 224 }
|
||
|
||
|
||
pm1001lhrMesrotx1AgingEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrotx1AgingEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrotx1Aging
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrotx1AgingIndex }
|
||
::= { pm1001lhrMesrotx1AgingTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrotx1AgingEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrotx1AgingIndex
|
||
INTEGER,
|
||
pm1001lhrMesrotx1AgingPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrotx1AgingIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrotx1Aging
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrotx1AgingEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrotx1AgingPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line OTX TLH Aging :This OID gives
|
||
the aging of the Line OTX TLH,
|
||
read from the DDM (Digital Diagnostic
|
||
Monitoring) (Aging = AV) (Unit
|
||
= %) <Help> This measure gives
|
||
the aging of the Line OTX TLH
|
||
"
|
||
::= { pm1001lhrMesrotx1AgingEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrotx1LaserTemperature articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrotx1LaserTemperatureTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrotx1LaserTemperatureEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrotx1LaserTemperature
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 225 }
|
||
|
||
|
||
pm1001lhrMesrotx1LaserTemperatureEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrotx1LaserTemperatureEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrotx1LaserTemperature
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrotx1LaserTemperatureIndex }
|
||
::= { pm1001lhrMesrotx1LaserTemperatureTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrotx1LaserTemperatureEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrotx1LaserTemperatureIndex
|
||
INTEGER,
|
||
pm1001lhrMesrotx1LaserTemperaturePortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrotx1LaserTemperatureIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrotx1LaserTemperature
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrotx1LaserTemperatureEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrotx1LaserTemperaturePortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
Line OTX TLH Laser Temperature
|
||
:This OID gives the laser temperature
|
||
of the Line OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Temperature = AV/256) (Unit =
|
||
C) <Help> This measure gives
|
||
the laser temperature of the Line
|
||
OTX TLH
|
||
"
|
||
::= { pm1001lhrMesrotx1LaserTemperatureEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrotx1FreqDeviation articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrotx1FreqDeviationTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrotx1FreqDeviationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrotx1FreqDeviation
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 226 }
|
||
|
||
|
||
pm1001lhrMesrotx1FreqDeviationEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrotx1FreqDeviationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrotx1FreqDeviation
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrotx1FreqDeviationIndex }
|
||
::= { pm1001lhrMesrotx1FreqDeviationTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrotx1FreqDeviationEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrotx1FreqDeviationIndex
|
||
INTEGER,
|
||
pm1001lhrMesrotx1FreqDeviationPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrotx1FreqDeviationIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrotx1FreqDeviation
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrotx1FreqDeviationEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrotx1FreqDeviationPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line OTX TLH Frequency Deviation
|
||
:This OID gives the frequency deviation
|
||
of the Line OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Deviation = (AV-32768)*100) (Unit
|
||
= MHz) <Help> This measure gives
|
||
the frequency deviation of the
|
||
Line OTX TLH
|
||
"
|
||
::= { pm1001lhrMesrotx1FreqDeviationEntry 2 }
|
||
|
||
|
||
--- *********************************************************
|
||
--- TABLE for the pm1001lhrMesrotx1LaserWvlength articles
|
||
--- *********************************************************
|
||
|
||
pm1001lhrMesrotx1LaserWvlengthTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrMesrotx1LaserWvlengthEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of pm1001lhrMesrotx1LaserWvlength
|
||
Article
|
||
"
|
||
::= { pm1001lhrMesrLine 227 }
|
||
|
||
|
||
pm1001lhrMesrotx1LaserWvlengthEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrMesrotx1LaserWvlengthEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the pm1001lhrMesrotx1LaserWvlength
|
||
table
|
||
"
|
||
INDEX { pm1001lhrMesrotx1LaserWvlengthIndex }
|
||
::= { pm1001lhrMesrotx1LaserWvlengthTable 1 }
|
||
|
||
|
||
Pm1001lhrMesrotx1LaserWvlengthEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrMesrotx1LaserWvlengthIndex
|
||
INTEGER,
|
||
pm1001lhrMesrotx1LaserWvlengthPortn
|
||
INTEGER
|
||
}
|
||
|
||
|
||
pm1001lhrMesrotx1LaserWvlengthIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the pm1001lhrMesrotx1LaserWvlength
|
||
table
|
||
"
|
||
::= { pm1001lhrMesrotx1LaserWvlengthEntry 1 }
|
||
|
||
|
||
pm1001lhrMesrotx1LaserWvlengthPortn OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Optical Module Wavelength
|
||
:This OID gives the laser wavelength
|
||
of the Line OTX TLH, read from
|
||
the DDM (Digital Diagnostic Monitoring)
|
||
(Wavelength=299792458/((193,100+(AV-32768
|
||
)*12,5)*10 3)) (Unit = nm) <Help>
|
||
This measure gives the laser wavelength
|
||
of the Line OTX TLH
|
||
"
|
||
::= { pm1001lhrMesrotx1LaserWvlengthEntry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- DOWNLOAD
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the restartProcess article
|
||
--- *****************************************************
|
||
pm1001lhrDwlrestartProcess OBJECT IDENTIFIER ::= { pm1001lhrDwlOther 0 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrDwlColdRestartProcessed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Cold Restart :This OID indicates
|
||
that the module last restart was
|
||
a Cold RESTART
|
||
"
|
||
::= { pm1001lhrDwlrestartProcess 2 }
|
||
|
||
|
||
|
||
pm1001lhrDwlWarmRestartProcessed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warm Restart :This OID indicates
|
||
that the module last restart was
|
||
a Warm RESTART
|
||
"
|
||
::= { pm1001lhrDwlrestartProcess 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swBanksUsed article
|
||
--- *****************************************************
|
||
pm1001lhrDwlswBanksUsed OBJECT IDENTIFIER ::= { pm1001lhrDwlOther 1 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrDwlSwBank2Notempty OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
SW bank 2 loaded :This OID indicates
|
||
a software is loaded in SW bank
|
||
2 <Help> This status indicates
|
||
if the SW bank 2 contains SW package
|
||
"
|
||
::= { pm1001lhrDwlswBanksUsed 6 }
|
||
|
||
|
||
|
||
pm1001lhrDwlSwBank1Notempty OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
SW bank 1 loaded :This OID indicates
|
||
a software is loaded in SW bank
|
||
1 <Help> This status indicates
|
||
if the SW bank 1 contains SW package
|
||
"
|
||
::= { pm1001lhrDwlswBanksUsed 5 }
|
||
|
||
|
||
|
||
pm1001lhrDwlSwBank2Used OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
SW bank 2 active :This OID indicates
|
||
the module is working on SW bank
|
||
2 <Help> This status indicates
|
||
if the SW bank 2 is active or standby
|
||
"
|
||
::= { pm1001lhrDwlswBanksUsed 2 }
|
||
|
||
|
||
|
||
pm1001lhrDwlSwBank1Used OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
SW bank 1 active :This OID indicates
|
||
the module is working on SW bank
|
||
1 <Help> This status indicates
|
||
if the SW bank 1 is active or standby
|
||
"
|
||
::= { pm1001lhrDwlswBanksUsed 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the gwBanksUsed article
|
||
--- *****************************************************
|
||
pm1001lhrDwlgwBanksUsed OBJECT IDENTIFIER ::= { pm1001lhrDwlOther 2 }
|
||
|
||
|
||
|
||
|
||
pm1001lhrDwlGwBank4Notempty OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW bank 4 loaded :This OID indicates
|
||
a gateware is loaded in GW bank
|
||
4
|
||
"
|
||
::= { pm1001lhrDwlgwBanksUsed 8 }
|
||
|
||
|
||
|
||
pm1001lhrDwlGwBank3Notempty OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW bank 3 loaded :This OID indicates
|
||
a gateware is loaded in GW bank
|
||
3 <Help> This status indicates
|
||
if the GW bank 3 contains GW package
|
||
"
|
||
::= { pm1001lhrDwlgwBanksUsed 7 }
|
||
|
||
|
||
|
||
pm1001lhrDwlGwBank2Notempty OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW bank 2 loaded :This OID indicates
|
||
a gateware is loaded in GW bank
|
||
2
|
||
"
|
||
::= { pm1001lhrDwlgwBanksUsed 6 }
|
||
|
||
|
||
|
||
pm1001lhrDwlGwBank1Notempty OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW bank 1 loaded :This OID indicates
|
||
a gateware is loaded in GW bank
|
||
1 <Help> This status indicates
|
||
if the GW bank 1 contains GW package
|
||
"
|
||
::= { pm1001lhrDwlgwBanksUsed 5 }
|
||
|
||
|
||
|
||
pm1001lhrDwlGwBank4Used OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW bank 4 active :This OID indicates
|
||
the module is working on GW bank
|
||
4
|
||
"
|
||
::= { pm1001lhrDwlgwBanksUsed 4 }
|
||
|
||
|
||
|
||
pm1001lhrDwlGwBank3Used OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW bank 3 active :This OID indicates
|
||
the module is working on GW bank
|
||
3 <Help> This status indicates
|
||
if the GW bank 3 is active or standby
|
||
"
|
||
::= { pm1001lhrDwlgwBanksUsed 3 }
|
||
|
||
|
||
|
||
pm1001lhrDwlGwBank2Used OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW bank 2 active :This OID indicates
|
||
the module is working on GW bank
|
||
2
|
||
"
|
||
::= { pm1001lhrDwlgwBanksUsed 2 }
|
||
|
||
|
||
|
||
pm1001lhrDwlGwBank1Used OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
GW bank 1 active :This OID indicates
|
||
the module is working on GW bank
|
||
1 <Help> This status indicates
|
||
if the GW bank 1 is active or standby
|
||
"
|
||
::= { pm1001lhrDwlgwBanksUsed 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONFIG
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group accessCAisCsf
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgAccessCAisCsf OBJECT IDENTIFIER ::= { pm1001lhrConfig 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group startup
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgStartup OBJECT IDENTIFIER ::= { pm1001lhrConfig 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2191
|
||
--- *****************************************************
|
||
|
||
pm1001lhrtablelineStartup OBJECT IDENTIFIER ::= { pm1001lhrCfgStartup 1 }
|
||
|
||
|
||
|
||
pm1001lhrCfgsystConfLine1 OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line 1 :This
|
||
register configures the default
|
||
initialisation settings on Line
|
||
port 1.
|
||
"
|
||
::= { pm1001lhrtablelineStartup 2 }
|
||
|
||
|
||
|
||
pm1001lhrCfgnetConfMod OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Protocol on Module :This
|
||
register configures the default
|
||
initialisation protocol on the
|
||
module.
|
||
"
|
||
::= { pm1001lhrtablelineStartup 3 }
|
||
|
||
|
||
|
||
pm1001lhrCfglineOptions1 OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Options on Active Line
|
||
Port :This register configures
|
||
the default options on the active
|
||
line port
|
||
"
|
||
::= { pm1001lhrtablelineStartup 5 }
|
||
|
||
|
||
|
||
pm1001lhrCfgsystConfLine2 OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line 2 :This
|
||
register configures the default
|
||
initialisation settings on Line
|
||
port 2.
|
||
"
|
||
::= { pm1001lhrtablelineStartup 6 }
|
||
|
||
|
||
|
||
pm1001lhrCfglineOptions2 OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Options on Active Line
|
||
Port :This register configures
|
||
the default options on the active
|
||
line port
|
||
"
|
||
::= { pm1001lhrtablelineStartup 9 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 21AB
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgXfpTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCfgXfpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pm1001lhrCfgStartup 2 }
|
||
|
||
|
||
pm1001lhrCfgXfpEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCfgXfpEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the startup
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCfgXfpIndex }
|
||
::= { pm1001lhrCfgXfpTable 1 }
|
||
|
||
|
||
Pm1001lhrCfgXfpEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCfgXfpIndex
|
||
INTEGER,
|
||
pm1001lhrCfgSystConfXfpPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgDataRateConfXfpPortn
|
||
Unsigned32
|
||
}
|
||
|
||
|
||
pm1001lhrCfgXfpIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the xfp table
|
||
"
|
||
::= { pm1001lhrCfgXfpEntry 1 }
|
||
|
||
|
||
pm1001lhrCfgSystConfXfpPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on XFP Port :This
|
||
register configures the default
|
||
initialisation settings on XFP
|
||
port.
|
||
"
|
||
::= { pm1001lhrCfgXfpEntry 3 }
|
||
|
||
|
||
pm1001lhrCfgDataRateConfXfpPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
:
|
||
"
|
||
::= { pm1001lhrCfgXfpEntry 4 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group labels
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgLabels OBJECT IDENTIFIER ::= { pm1001lhrConfig 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgLabelclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pm1001lhrCfgLabels 1 }
|
||
|
||
|
||
pm1001lhrCfgLabelclientEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCfgLabelclientIndex }
|
||
::= { pm1001lhrCfgLabelclientTable 1 }
|
||
|
||
|
||
Pm1001lhrCfgLabelclientEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCfgLabelclientIndex
|
||
INTEGER,
|
||
pm1001lhrCfgLabelclientPortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pm1001lhrCfgLabelclientIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelclient
|
||
table
|
||
"
|
||
::= { pm1001lhrCfgLabelclientEntry 1 }
|
||
|
||
|
||
pm1001lhrCfgLabelclientPortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the Ports :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the ports.
|
||
"
|
||
::= { pm1001lhrCfgLabelclientEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgLabellineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pm1001lhrCfgLabels 2 }
|
||
|
||
|
||
pm1001lhrCfgLabellineEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCfgLabellineIndex }
|
||
::= { pm1001lhrCfgLabellineTable 1 }
|
||
|
||
|
||
Pm1001lhrCfgLabellineEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCfgLabellineIndex
|
||
INTEGER,
|
||
pm1001lhrCfgLabellinePortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pm1001lhrCfgLabellineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelline
|
||
table
|
||
"
|
||
::= { pm1001lhrCfgLabellineEntry 1 }
|
||
|
||
|
||
pm1001lhrCfgLabellinePortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the lines :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the lines.
|
||
"
|
||
::= { pm1001lhrCfgLabellineEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group startuptlh
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgStartuptlh OBJECT IDENTIFIER ::= { pm1001lhrConfig 4 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 25A8
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgOtxtlhTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCfgOtxtlhEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pm1001lhrCfgStartuptlh 1 }
|
||
|
||
|
||
pm1001lhrCfgOtxtlhEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCfgOtxtlhEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the startuptlh
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCfgOtxtlhIndex }
|
||
::= { pm1001lhrCfgOtxtlhTable 1 }
|
||
|
||
|
||
Pm1001lhrCfgOtxtlhEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCfgOtxtlhIndex
|
||
INTEGER,
|
||
pm1001lhrCfgNuPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgLineDitherRatePortn
|
||
Unsigned32,
|
||
pm1001lhrCfgLineDitherFhzPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgLinePwrLaserPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgLineFCurrentPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgLineGridCurrentPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgFPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgReservedPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgLinePhotodiodeModePortn
|
||
Unsigned32,
|
||
pm1001lhrCfgLinePhotodiodeValuePortn
|
||
Unsigned32
|
||
}
|
||
|
||
|
||
pm1001lhrCfgOtxtlhIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the otxtlh
|
||
table
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 1 }
|
||
|
||
|
||
pm1001lhrCfgNuPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
:
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 3 }
|
||
|
||
|
||
pm1001lhrCfgLineDitherRatePortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line OTX TLH FM amplitude
|
||
:This register configures the start-up
|
||
width of the frequency modulation
|
||
of the Line OTX TLH
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 4 }
|
||
|
||
|
||
pm1001lhrCfgLineDitherFhzPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line OTX TLH FM frequency
|
||
:This register configures the start-up
|
||
frequency of the frequency modulation
|
||
of the Line OTX TLH
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 5 }
|
||
|
||
|
||
pm1001lhrCfgLinePwrLaserPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Defaut Line OTX TLH output Power
|
||
:This register configures the start-up
|
||
output power of the Line OTX TLH
|
||
(Unit = dBm)
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 6 }
|
||
|
||
|
||
pm1001lhrCfgLineFCurrentPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line OTX TLH Channel :This
|
||
register configures the start-up
|
||
laser channel of the Line OTX TLH
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 7 }
|
||
|
||
|
||
pm1001lhrCfgLineGridCurrentPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line OTX TLH Grid :This
|
||
register configures the start-up
|
||
laser grid of the Line OTX TLH
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 8 }
|
||
|
||
|
||
pm1001lhrCfgFPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line OTX TLH lowest Freq
|
||
:This register configures the start-up
|
||
lowest frequency supported on the
|
||
Line OTX TLH
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 9 }
|
||
|
||
|
||
pm1001lhrCfgReservedPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS deprecated
|
||
DESCRIPTION
|
||
"
|
||
:
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 10 }
|
||
|
||
|
||
pm1001lhrCfgLinePhotodiodeModePortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line OTX TLH APD mode
|
||
:This register configures the
|
||
start-up APD mode of the Line
|
||
OTX TLH
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 11 }
|
||
|
||
|
||
pm1001lhrCfgLinePhotodiodeValuePortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Line OTX TLH APD atten.
|
||
:This register configures the start-up
|
||
APD attenuation on the Line OTX
|
||
TLH
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhEntry 12 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group startuptablefive
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgStartuptablefive OBJECT IDENTIFIER ::= { pm1001lhrConfig 5 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 0005
|
||
--- *****************************************************
|
||
|
||
pm1001lhrCfgOtxtlhcapabilitiesTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pm1001lhrCfgOtxtlhcapabilitiesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pm1001lhrCfgStartuptablefive 1 }
|
||
|
||
|
||
pm1001lhrCfgOtxtlhcapabilitiesEntry OBJECT-TYPE
|
||
SYNTAX Pm1001lhrCfgOtxtlhcapabilitiesEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the startuptablefive
|
||
table
|
||
"
|
||
INDEX { pm1001lhrCfgOtxtlhcapabilitiesIndex }
|
||
::= { pm1001lhrCfgOtxtlhcapabilitiesTable 1 }
|
||
|
||
|
||
Pm1001lhrCfgOtxtlhcapabilitiesEntry ::=
|
||
SEQUENCE {
|
||
pm1001lhrCfgOtxtlhcapabilitiesIndex
|
||
INTEGER,
|
||
pm1001lhrCfgComponentTypePortn
|
||
Unsigned32,
|
||
pm1001lhrCfgMiscellaneousPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgFirstChannelPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgLastChannelPortn
|
||
Unsigned32,
|
||
pm1001lhrCfgGridPortn
|
||
Unsigned32
|
||
}
|
||
|
||
|
||
pm1001lhrCfgOtxtlhcapabilitiesIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the otxtlhcapabilities
|
||
table
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 1 }
|
||
|
||
|
||
pm1001lhrCfgComponentTypePortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Component parameters :This OID
|
||
defines the component parameters
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 3 }
|
||
|
||
|
||
pm1001lhrCfgMiscellaneousPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Miscellaneous default settings
|
||
:This OID defines the miscellaneous
|
||
parameters
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 4 }
|
||
|
||
|
||
pm1001lhrCfgFirstChannelPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Number of the first channel of
|
||
the component :This OID defines
|
||
the first channel number of the
|
||
PM
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 5 }
|
||
|
||
|
||
pm1001lhrCfgLastChannelPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Number of the last channel of
|
||
the component :This OID defines
|
||
the last channel number of the
|
||
PM
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 6 }
|
||
|
||
|
||
pm1001lhrCfgGridPortn OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Grid value of the component :This
|
||
OID defines the grid of the PM
|
||
"
|
||
::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 7 }
|
||
|
||
|
||
|
||
pm1001lhrCfgWriteConfiguration OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write configuration to module:This OID
|
||
writes the complete configuration to the module"
|
||
::= { pm1001lhrConfig 257 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- TRAP OBJECTS
|
||
--- *****************************************************
|
||
|
||
pm1001lhrtrapLineNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last Line which generates a trap"
|
||
::= { pm1001lhrtraps 3 }
|
||
|
||
pm1001lhrtrapBoardNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last module which generates a trap"
|
||
::= { pm1001lhrtraps 4 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LINE TRAPS
|
||
--- *****************************************************
|
||
|
||
pm1001lhrLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm1001lhrAlmLineDdmWarningPortn, pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM1001LHR Line Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pm1001lhrAlmLineDdmWarningPortn "on", pm1001lhrtrapLineNumber "$2", pm1001lhrtrapBoardNumber "$3"}
|
||
--&MESG "DDM Warning appears on Line Port $2 of PM1001LHR in Slot $3 ($A)"
|
||
DESCRIPTION "Not urgent Line default is activated"
|
||
::= { pm1001lhrtraps 30 }
|
||
|
||
pm1001lhrLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm1001lhrAlmLineDdmWarningPortn, pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM1001LHR Line Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM1001LHR Line Not Urgent ON" }
|
||
--&MATCH { pm1001lhrAlmLineDdmWarningPortn "on", pm1001lhrtrapLineNumber "$2", pm1001lhrtrapBoardNumber "$3"}
|
||
--&MESG "DDM Warning disappears on Line Port $2 of PM1001LHR in Slot $3 ($A)"
|
||
DESCRIPTION "Not urgent Line default disappeared"
|
||
::= { pm1001lhrtraps 31 }
|
||
|
||
pm1001lhrLineTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm1001lhrAlmLineDdmAlmPortn, pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM1001LHR Line Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pm1001lhrAlmLineDdmAlmPortn "on", pm1001lhrtrapLineNumber "$2", pm1001lhrtrapBoardNumber "$3"}
|
||
--&MESG "DDM Alarm appears on Line Port $2 of PM1001LHR in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent Line default is activated"
|
||
::= { pm1001lhrtraps 32 }
|
||
|
||
pm1001lhrLineTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm1001lhrAlmLineDdmAlmPortn, pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM1001LHR Line Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM1001LHR Line Urgent ON" }
|
||
--&MATCH { pm1001lhrAlmLineDdmAlmPortn "on", pm1001lhrtrapLineNumber "$2", pm1001lhrtrapBoardNumber "$3"}
|
||
--&MESG "DDM Alarm disappears on Line Port $2 of PM1001LHR in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent Line default disappeared"
|
||
::= { pm1001lhrtraps 33 }
|
||
|
||
pm1001lhrLineTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm1001lhrAlmLineFailPortn , pm1001lhrAlmLineHwFailPortn , pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM1001LHR Line Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pm1001lhrAlmLineFailPortn "on", pm1001lhrAlmLineHwFailPortn "*", pm1001lhrtrapLineNumber "$3", pm1001lhrtrapBoardNumber "$4"}
|
||
--&MESG "Line Port $3 Down on PM1001LHR in Slot $4 ($A)"
|
||
|
||
--&FILTNAME "PM1001LHR Line HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pm1001lhrAlmLineFailPortn "*", pm1001lhrAlmLineHwFailPortn "on", pm1001lhrtrapLineNumber "$3", pm1001lhrtrapBoardNumber "$4"}
|
||
--&MESG "Line Port $3 Down on PM1001LHR in Slot $4 ($A)"
|
||
DESCRIPTION "Critical Line default is activated"
|
||
::= { pm1001lhrtraps 34 }
|
||
|
||
pm1001lhrLineTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm1001lhrAlmLineFailPortn , pm1001lhrAlmLineHwFailPortn , pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM1001LHR Line Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM1001LHR Line Fail ON" }
|
||
--&MATCH { pm1001lhrAlmLineFailPortn "on", pm1001lhrAlmLineHwFailPortn "*", pm1001lhrtrapLineNumber "$3", pm1001lhrtrapBoardNumber "$4"}
|
||
--&MESG "Line Port $3 Up on PM1001LHR in Slot $4 ($A)"
|
||
|
||
--&FILTNAME "PM1001LHR Line HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pm1001lhrAlmLineFailPortn "*", pm1001lhrAlmLineHwFailPortn "on", pm1001lhrtrapLineNumber "$3", pm1001lhrtrapBoardNumber "$4"}
|
||
--&MESG "Line Port $3 Up on PM1001LHR in Slot $4 ($A)"
|
||
DESCRIPTION "Critical Line default disappeared"
|
||
::= { pm1001lhrtraps 35 }
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- HW TRAPS
|
||
--- *****************************************************
|
||
|
||
pm1001lhrPowerTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pm1001lhrAlmDefFuseB, pm1001lhrAlmDefFuseA , pm1001lhrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM1001LHR Fuse A Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pm1001lhrAlmDefFuseB "*", pm1001lhrAlmDefFuseA "on", pm1001lhrtrapBoardNumber "$3"}
|
||
--&MESG "Power Input A Fail on PM1001LHR in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM1001LHR Fuse B Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pm1001lhrAlmDefFuseB "on", pm1001lhrAlmDefFuseA "*", pm1001lhrtrapBoardNumber "$3"}
|
||
--&MESG "Power Input B Fail on PM1001LHR in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default is activated"
|
||
::= { pm1001lhrtraps 50 }
|
||
|
||
pm1001lhrPowerTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pm1001lhrAlmDefFuseB, pm1001lhrAlmDefFuseA , pm1001lhrtrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM1001LHR Fuse A&B Fail OFF"
|
||
--&ACTIONS { log, normal}
|
||
--&CLEARS { "PM1001LHR Fuse A Fail ON", "PM1001LHR Fuse B Fail ON" }
|
||
--&MATCH { pm1001lhrAlmDefFuseB "on", pm1001lhrAlmDefFuseA "on", pm1001lhrtrapBoardNumber "$3"}
|
||
--&MESG "Power Inputs A and B Present on PM1001LHR in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default disappeared"
|
||
::= { pm1001lhrtraps 51 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
END
|