Observium_CE/mibs/d-link/DLINK-WLAN-MIB

1291 lines
44 KiB
Plaintext

-- DLINK Private MIB
-- DLINK agents also support the following Public MIBs:
-- MIB-II ( RFC1213 )
-- dlkEnterpriseAP-dlk80211bPlus MODULE
DLINK-WLAN-MIB DEFINITIONS ::= BEGIN
IMPORTS
mgmt, enterprises, IpAddress FROM RFC1155-SMI
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI
-- OBJECT-TYPE, Integer32, Counter32 FROM RFC-1212
DisplayString, MacAddress, RowStatus,
TruthValue FROM SNMPv2-TC
ifIndex FROM RFC1213-MIB
;
--mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) }
--mib OBJECT IDENTIFIER ::= { mgmt 1 }
--directory OBJECT IDENTIFIER ::= { internet 1 }
--experimental OBJECT IDENTIFIER ::= { internet 3 }
--private OBJECT IDENTIFIER ::= { internet 4 }
--enterprises OBJECT IDENTIFIER ::= { private 1 }
dlink OBJECT IDENTIFIER ::= { enterprises 171 }
--should be implemented as module
--dlkEnterpriseAP OBJECT IDENTIFIER ::= { dlink 1 }
--dlkWLANRouter OBJECT IDENTIFIER ::= { dlink 2 }
--dlkRouter OBJECT IDENTIFIER ::= { dlink 3 }
-- **********************************************************************
-- * MODULE IDENTITY
-- **********************************************************************
dlkEnterpriseAP MODULE-IDENTITY
LAST-UPDATED "200208160000Z"
ORGANIZATION "D-Link, Inc."
CONTACT-INFO
"Postal: D-Link, Inc.
2F, No.233-2, Pao-Chiao Road,
Hsin-Tien, Taipei,
Taiwan, R.O.C.
Tel: +886-2-29161600
Fax: +886-2-29146299"
DESCRIPTION
"The MIB module for D-Link 802.11 series product.
This module derived from IEEE ieee802dot11"
::= { dlink 1 }
-- **********************************************************************
-- * end of MODULE IDENTITY
-- **********************************************************************
-- dlkEnterpriseAP OBJECT IDs Groups
dlkEnterpriseAPsys OBJECT IDENTIFIER ::= { dlkEnterpriseAP 1 }
dlkEnterpriseAPlan OBJECT IDENTIFIER ::= { dlkEnterpriseAP 2 }
dlk80211bPlusDot11 OBJECT IDENTIFIER ::= { dlkEnterpriseAP 3 }
dlkEnterpriseAPTrap OBJECT IDENTIFIER ::= { dlkEnterpriseAP 4 }
-- **********************************************************************
-- * Major sections
-- **********************************************************************
-- **********************************************************************
-- * dlkEnterpriseAPsys sections
-- **********************************************************************
enterpriseAPSysConfigSave OBJECT-TYPE
SYNTAX INTEGER { write(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User must manually SET this OID in order to save the change(s) made through SNMP to
main configuration."
::= { dlkEnterpriseAPsys 1 }
enterpriseAPSysReboot OBJECT-TYPE
SYNTAX INTEGER { reboot(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is to reboot the enterprise AP system.
Doesn't save the changes that had been made."
::= { dlkEnterpriseAPsys 2 }
enterpriseAPSysConfigApply OBJECT-TYPE
SYNTAX INTEGER { saveAndReboot(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is equivalent of setting enterpriseAPSysConfigSave then
enterpriseAPSysConfigApply."
::= { dlkEnterpriseAPsys 3 }
-- **********************************************************************
-- * end of dlkEnterpriseAPsys sections
-- **********************************************************************
-- Station ManagemenT (SMT) Attributes
-- DEFINED AS "The SMT object class provides the necessary support at the
-- station to manage the processes in the station such that the
-- station may work cooperatively as a part of an IEEE 802.11 network.";
dot11smt OBJECT IDENTIFIER ::= { dlk80211bPlusDot11 1 }
dot11StationConfigEntry OBJECT IDENTIFIER ::= { dot11smt 1 }
dot11APModeConfigEntry OBJECT IDENTIFIER ::= { dot11smt 2 }
dot11PrivacyEntry OBJECT IDENTIFIER ::= { dot11smt 3 }
-- MAC Attributes
-- DEFINED AS "The MAC object class provides the necessary support
-- for the access control, generation, and verification of frame check
-- sequences, and proper delivery of valid data to upper layers.";
dot11mac OBJECT IDENTIFIER ::= {dlk80211bPlusDot11 2}
dot11OperationEntry OBJECT IDENTIFIER ::= {dot11mac 1}
dot11CountersEntry OBJECT IDENTIFIER ::= {dot11mac 2}
-- dot11GroupAddressesTable ::= {dot11mac 3}
-- Resource Type ID
dot11res OBJECT IDENTIFIER ::= {dlk80211bPlusDot11 3}
dot11resAttribute OBJECT IDENTIFIER ::= {dot11res 1 }
-- PHY Attributes
-- DEFINED AS "The PHY object class provides the necessary support
-- for required PHY operational information that may vary from PHY
-- to PHY and from STA to STA to be communicated to upper layers."
dot11phy OBJECT IDENTIFIER ::= {dlk80211bPlusDot11 4}
dot11PhyOperationEntry OBJECT IDENTIFIER ::= {dot11phy 1}
dot11PhyAntennaEntry OBJECT IDENTIFIER ::= {dot11phy 2}
dot11PhyTxPowerEntry OBJECT IDENTIFIER ::= {dot11phy 3}
dot11PhyDSSSEntry OBJECT IDENTIFIER ::= {dot11phy 4}
-- ****************************************************************************************
-- dlkEnterpriseAPsys - system/platform MIB elements
-- ****************************************************************************************
-- ****************************************************************************************
-- dlkEnterpriseAPlan - Ethernet Standard MIB elements
-- ****************************************************************************************
-- **********************************************************************
-- * Textual conventions from 802 definitions
-- **********************************************************************
-- **********************************************************************
-- * SMT Station Config Table
-- **********************************************************************
dot11StationID OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The purpose of dot11StationID is to allow a manager to identify
a station for its own purposes. This attribute provides
for that eventuality while keeping the true MAC address
independent. Its syntax is MAC address and default value
is the station's assigned, unique MAC address."
::= { dot11StationConfigEntry 1 }
dot11PrivacyOptionImplemented OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute, when true, shall indicate that the IEEE
802.11 WEP option is implemented. The default value of
this attribute shall be false."
::= { dot11StationConfigEntry 2 }
dot11PowerManagementMode OBJECT-TYPE
SYNTAX INTEGER { active(1), powersave(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute shall specify the power management
mode of the STA. When set to active, it shall indicate
that the station is not in power-save mode. When set
to powersave, it shall indicate that the station is
in power-save mode. The power management mode is
transmitted in all frames according to the rules
in 7.1.3.1.7."
::= { dot11StationConfigEntry 3 }
dot11DesiredSSID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute reflects the Service Set ID used
in the DesiredSSID parameter of the most recent
MLME_Scan.request. This value may be modified
by an external management entity and used by the
local SME to make decisions about the Scanning process."
::= { dot11StationConfigEntry 4 }
dot11DesiredBSSType OBJECT-TYPE
SYNTAX INTEGER { infrastructure(1), independent(2), any(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute shall specify the type of BSS the
station shall use when scanning for a BSS with which
to synchronize. This value is used to filter Probe
Response frames and Beacons. When set to infrastructure,
the station shall only synchronize with a BSS whose
Capability Information field has the ESS subfield set
to 1. When set to independent, the station shall only
synchronize with a BSS whose Capability Information
field has the IBSS subfield set to 1. When set to
any, the station may synchronize to either type of
BSS."
::= { dot11StationConfigEntry 5 }
dot11OperationalRateSet OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..126))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall specify the set of data rates
at which the station may transmit data. Each octet
contains a value representing a rate. Each rate
shall be within the range from 2 to 127,
corresponding to data rates in increments of
500 kb/s from 1 Mb/s to 63.5 Mb/s, and shall be
supported (as indicated in the supported rates
table) for receiving data. This value is reported in
transmitted Beacon, Probe Request, Probe Response,
Association Request, Association Response,
Reassociation Request, and Reassociation Response
frames, and is used to determine whether a BSS
with which the station desires to synchronize is
suitable. It is also used when starting a BSS,
as specified in 10.3.
This atribute also indicate the Basic Rate of the AP,
rate that is used as transmit rate of 802.11
management and control packet. If 22Mbps is as
basic rate, the bit 7(MSB) should be set(i.e. 0xAC,
instead of 0x2C).
Valid basic rate are (2-1)Mbps, (11-5.5-2-1)Mbps,
(22-11-5.5-2-1)Mbps.
example:
(2-1)Mbps : 0x2C160B8482
(11-5.5-2-1)Mbps : 0x2C968B8482
(22-11-5.5-2-1)Mbps : 0xAC968B8482"
::= { dot11StationConfigEntry 6 }
dot11BeaconPeriod OBJECT-TYPE
SYNTAX INTEGER (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall specify the number of TU that a
station shall use for scheduling Beacon transmissions.
This value is transmitted in Beacon and Probe Response
frames."
::= { dot11StationConfigEntry 7 }
dot11DTIMPeriod OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall specify the number of beacon
intervals that shall elapse between transmission of
Beacons frames containing a TIM element whose DTIM
Count field is 0. This value is transmitted in
the DTIM Period field of Beacon frames."
::= { dot11StationConfigEntry 8 }
dot11DisassociateReason OBJECT-TYPE
SYNTAX INTEGER(0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute holds the most recently
transmitted Reason Code in a Disassociation
frame. If no Disassociation frame has been
transmitted, the value of this attribute shall
be 0."
REFERENCE "IEEE Std 802.11-1997, 7.3.1.7"
::= { dot11StationConfigEntry 9 }
dot11DisassociateStation OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute holds the MAC address from the
Address 1 field of the most recently transmitted
Disassociation frame. If no Disassociation
frame has been transmitted, the value of this
attribute shall be 0."
::= { dot11StationConfigEntry 10 }
dot11DeauthenticateReason OBJECT-TYPE
SYNTAX INTEGER(0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute holds the most recently
transmitted Reason Code in a Deauthentication
frame. If no Deauthentication frame has been
transmitted, the value of this attribute shall
be 0."
REFERENCE "IEEE Std 802.11-1997, 7.3.1.7"
::= { dot11StationConfigEntry 11 }
dot11DeauthenticateStation OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute holds the MAC address from the
Address 1 field of the most recently transmitted
Deauthentication frame. If no Deauthentication
frame has been transmitted, the value of this
attribute shall be 0."
::= { dot11StationConfigEntry 12 }
dot11AuthenticateFailStatus OBJECT-TYPE
SYNTAX INTEGER(0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute holds the most recently
transmitted Status Code in a failed
Authentication frame. If no failed
Authentication frame has been transmitted, the
value of this attribute shall be 0."
REFERENCE "IEEE Std 802.11-1997, 7.3.1.9"
::= { dot11StationConfigEntry 13 }
-- **********************************************************************
-- * End of dot11StationConfig TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11EnterpriseConfigEntry TABLE
-- **********************************************************************
dot11AccessPointMode OBJECT-TYPE
SYNTAX INTEGER { accessPoint (1),
wirelessBridge (2),
wirelessAPClient (3),
wirelessMultiBridge (4),
backupAccessPoint (5),
repeater (6),
groupAccessPoint (7) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall be a set of all the access point mode
supported by the AP. The following are the
default values and the associated mode.
Value = 1: Normal AP
Value = 2: Wireless Bridge
Value = 3: Wireless AP Client
Value = 4: Wireless Multi Bridge
Value = 5: Backup AP
Value = 6: Repeater
Value = 7: Group AP"
::= { dot11APModeConfigEntry 1 }
dot11RemoteMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This Remote MAC Address used by these following AP mode:
Wireless Bridge, Wireless AP Client, Backup AP, Repeater.
Consequently, this attribute must be set if any above mentioned
mode is desired."
::= { dot11APModeConfigEntry 2 }
dot11BackupAPRemoteServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute used to check the wired LAN connection
(A.K.A. Link Integrity) when AP in Backup AP mode."
::= { dot11APModeConfigEntry 3 }
dot11GroupAPID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is to identify current Group ID of the AP."
::= { dot11APModeConfigEntry 4 }
-- **********************************************************************
-- * End of dot11EnterpriseConfigEntry TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11PrivacyTable TABLE
-- **********************************************************************
dot11AuthenticationAlgorithm OBJECT-TYPE
SYNTAX INTEGER { openSystem (1), sharedKey (2), both (3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute shall be the authentication algorithms currently used
by the AP. The following are the default values and the associated algorithm.
Value = 1: Open System
Value = 2: Shared Key
Value = 3: Both Open System and Shared Key"
::= { dot11PrivacyEntry 1 }
dot11PrivacyInvoked OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this attribute is true, it shall indicate that the IEEE
802.11 WEP mechanism is used for transmitting frames of type
Data. The default value of this attribute shall be false."
::= { dot11PrivacyEntry 2 }
dot11WEPDefaultKeyID OBJECT-TYPE
SYNTAX INTEGER (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall indicate the use of the first,
second, third, or fourth element of the WEPDefaultKeys
array when set to values of zero, one, two, or three. The
default value of this attribute shall be 0."
REFERENCE "IEEE Std 802.11-1997, 8.3.2"
::= { dot11PrivacyEntry 3 }
dot11WEPKeyLength OBJECT-TYPE
SYNTAX INTEGER { w-64Bit (1), w-128Bit (2), w-256Bit (3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall indicate the length of WEP encryption length used.
Value 1: 64 bit that need 5 characters of WEP Default Key
Value 2: 128 bit that need 13 characters of WEP Default Key
Value 3: 256 bit that need 29 characters of WEP Default Key"
::= { dot11PrivacyEntry 4 }
dot11WEPKeyMappingLength OBJECT-TYPE
SYNTAX INTEGER (10..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of tuples that dot11WEPKeyMappings can hold."
REFERENCE "IEEE Std 802.11-1997, 8.3.2"
::= { dot11PrivacyEntry 5 }
dot11ExcludeUnencrypted OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When this attribute is true, the STA shall not indicate at
the MAC service interface received MSDUs that have the WEP
subfield of the Frame Control field equal to zero. When this
attribute is false, the STA may accept MSDUs that have the WEP
subfield of the Frame Control field equal to zero. The default
value of this attribute shall be false."
::= { dot11PrivacyEntry 6 }
dot11WEPICVErrorCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when a frame is received with the
WEP subfield of the Frame Control field set to one and the value
of the ICV as received in the frame does not match the ICV value
that is calculated for the contents of the received frame."
::= { dot11PrivacyEntry 7 }
dot11WEPExcludedCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when a frame is received with the
WEP subfield of the Frame Control field set to zero and the value
of dot11ExcludeUnencrypted causes that frame to be discarded."
::= { dot11PrivacyEntry 8 }
-- **********************************************************************
-- * End of dot11Privacy TABLE
-- **********************************************************************
-- **********************************************************************
-- * MAC Attribute Templates
-- **********************************************************************
-- **********************************************************************
-- * dot11OperationTable TABLE
-- **********************************************************************
dot11MACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique MAC Address assigned to the STA."
::= { dot11OperationEntry 1 }
dot11RTSThreshold OBJECT-TYPE
SYNTAX INTEGER (256..2432)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall indicate the number of octets in an MPDU,
below which an RTS/CTS handshake shall not be performed. An
RTS/CTS handshake shall be performed at the beginning of any
frame exchange sequence where the MPDU is of type Data or
Management, the MPDU has an individual address in the Address1
field, and the length of the MPDU is greater than
this threshold. (For additional details, refer to Table 21 in
9.7.) Setting this attribute to be larger than the maximum
MSDU size shall have the effect of turning off the RTS/CTS
handshake for frames of Data or Management type transmitted by
this STA. Setting this attribute to zero shall have the effect
of turning on the RTS/CTS handshake for all frames of Data or
Management type transmitted by this STA. The default value of
this attribute shall be 2347."
::= { dot11OperationEntry 2 }
dot11ShortRetryLimit OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall indicate the maximum number of
transmission attempts of a frame, the length of which is less
than or equal to dot11RTSThreshold, that shall be made before a
failure condition is indicated. The default value of this
attribute shall be 7."
::= { dot11OperationEntry 3 }
dot11LongRetryLimit OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall indicate the maximum number of
transmission attempts of a frame, the length of which is
greater than dot11RTSThreshold, that shall be made before a
failure condition is indicated. The default value of this
attribute shall be 4."
::= { dot11OperationEntry 4 }
dot11FragmentationThreshold OBJECT-TYPE
SYNTAX INTEGER (256..2346)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall specify the current maximum size, in
octets, of the MPDU that may be delivered to the PHY. An MSDU
shall be broken into fragments if its size exceeds the value
of this attribute after adding MAC headers and trailers. An MSDU or MMPDU shall be fragmented when the resulting frame has an individual address in the Address1 field, and the length of the frame is larger than this threshold. The default value for this attribute shall be the lesser of 2346 or the aMPDUMaxLength of the attached PHY and shall never exceed the lesser of 2346 or the aMPDUMaxLength of the attached PHY. The value of this attribute shall never be less than 256. "
::= { dot11OperationEntry 5 }
dot11SSIDBroadcast OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicate whether SSID broadcast is enabled."
::= { dot11OperationEntry 6 }
dot11PreambleType OBJECT-TYPE
SYNTAX INTEGER { longPreamble (1), shortPreamble (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicate what preamble type is used.
The default value should be Long Preamble."
::= { dot11OperationEntry 7 }
dot11MaxTransmitMSDULifetime OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MaxTransmitMSDULifetime shall be the elapsed time in TU,
after the initial transmission of an MSDU, after which further
attempts to transmit the MSDU shall be terminated. The default
value of this attribute shall be 512."
::= { dot11OperationEntry 8 }
dot11MaxReceiveLifetime OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MaxReceiveLifetime shall be the elapsed time in TU,
after the initial reception of a fragmented MMPDU or MSDU,
after which further attempts to reassemble the MMPDU or
MSDU shall be terminated. The default value shall be
512."
::= { dot11OperationEntry 9 }
dot11ManufacturerID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ManufacturerID shall include, at a minimum, the name
of the manufacturer. It may include additional
information at the manufacturer's discretion. The default
value of this attribute shall be null."
::= { dot11OperationEntry 10 }
dot11ProductID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ProductID shall include, at a minimum, an identifier
that is unique to the manufacturer. It may include
additional information at the manufacturer's discretion.
The default value of this attribute shall be null."
::= { dot11OperationEntry 11 }
-- **********************************************************************
-- * End of dot11OperationEntry TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11Counters TABLE
-- **********************************************************************
dot11TransmittedFragmentCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall be incremented for an acknowledged MPDU
with an individual address in the address 1 field or an MPDU
with a multicast address in the address 1 field of type Data
or Management."
::= { dot11CountersEntry 1 }
dot11MulticastTransmittedFrameCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This counter shall increment only when the multicast bit
is set in the destination MAC address of a successfully
transmitted MSDU. When operating as a STA in an ESS, where
these frames are directed to the AP, this implies having
received an acknowledgment to all associated MPDUs. "
::= { dot11CountersEntry 2 }
dot11FailedCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when an MSDU is not transmitted
successfully due to the number of transmit attempts exceeding
either the dot11ShortRetryLimit or dot11LongRetryLimit. "
::= { dot11CountersEntry 3 }
dot11RetryCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when an MSDU is successfully
transmitted after one or more retransmissions."
::= { dot11CountersEntry 4 }
dot11MultipleRetryCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when an MSDU is successfully
transmitted after more than one retransmission."
::= { dot11CountersEntry 5 }
dot11FrameDuplicateCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when a frame is received
that the Sequence Control field indicates is a
duplicate."
::= { dot11CountersEntry 6 }
dot11RTSSuccessCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when a CTS is received in
response to an RTS."
::= { dot11CountersEntry 7 }
dot11RTSFailureCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when a CTS is not received in
response to an RTS."
::= { dot11CountersEntry 8 }
dot11ACKFailureCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when an ACK is not received
when expected."
::= { dot11CountersEntry 9 }
dot11ReceivedFragmentCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall be incremented for each successfully
received MPDU of type Data or Management."
::= { dot11CountersEntry 10 }
dot11MulticastReceivedFrameCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when a MSDU is received
with the multicast bit set in the destination
MAC address."
::= { dot11CountersEntry 11 }
dot11FCSErrorCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when an FCS error is
detected in a received MPDU."
::= { dot11CountersEntry 12 }
dot11TransmittedFrameCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment for each successfully transmitted MSDU."
::= { dot11CountersEntry 13 }
dot11WEPUndecryptableCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter shall increment when a frame is received with
the WEP subfield of the Frame Control field set to one and the
WEPOn value for the key mapped to the TA's MAC address
indicates that the frame should not have been encrypted or
that frame is discarded due to the receiving STA not
implementing the privacy option."
::= { dot11CountersEntry 14 }
-- **********************************************************************
-- * End of dot11CountersEntry TABLE
-- **********************************************************************
-- **********************************************************************
-- * Resource Type Attribute Templates
-- **********************************************************************
dot11ResourceTypeIDName OBJECT-TYPE
SYNTAX DisplayString (SIZE(4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the name of the Resource Type ID managed object.
The attribute is read-write and always contains the value
RTID. This attribute value shall not be used as a naming
attribute for any other managed object class."
REFERENCE "IEEE Std 802.1F-1993, A.7"
DEFVAL {"RTID"}
::= { dot11resAttribute 1 }
-- **********************************************************************
-- * dot11ResourceInfo TABLE
-- **********************************************************************
-- REFERENCE "IEEE Std 802.1F-1993, A.7"
dot11ResourceInfoEntry OBJECT IDENTIFIER ::= { dot11resAttribute 2 }
dot11manufacturerOUI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Takes the value of an organizationally unique identifier.
0x00032F for D-Link, Inc."
::= { dot11ResourceInfoEntry 1 }
dot11manufacturerName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A printable string used to identify the manufacturer of the
resource. Maximum string length is 128 octets.
D-Link, Inc."
::= { dot11ResourceInfoEntry 2 }
dot11manufacturerProductName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A printable string used to identify the manufacturer's product
name of the resource. Maximum string length is 128 octets."
::= { dot11ResourceInfoEntry 3 }
dot11manufacturerProductVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Printable string used to identify the manufacturer's product
version of the resource. Maximum string length is 128 octets."
::= { dot11ResourceInfoEntry 4 }
-- **********************************************************************
-- * End of dot11ResourceInfo TABLE
-- **********************************************************************
-- **********************************************************************
-- * PHY Attribute Templates
-- **********************************************************************
-- **********************************************************************
-- * dot11PhyOperation TABLE
-- **********************************************************************
dot11PHYType OBJECT-TYPE
SYNTAX INTEGER {fhss(1), dsss(2), irbaseband(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an 8-bit integer value that identifies the PHY type
supported by the attached PLCP and PMD. Currently defined
values and their corresponding PHY types are:
FHSS 2.4 GHz = 01 , DSSS 2.4 GHz = 02, IR Baseband = 03"
::= { dot11PhyOperationEntry 1 }
dot11CurrentRegDomain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current regulatory domain this instance of the PMD is
supporting. This object corresponds to one of the
RegDomains listed in dot11RegDomainsSupported."
::= { dot11PhyOperationEntry 2 }
dot11TempType OBJECT-TYPE
SYNTAX INTEGER {tempType1(1), tempType2(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"There are different operating temperature requirements
dependent on the anticipated environmental conditions. This
attribute describes the current PHY's operating temperature
range capability. Currently defined values and their
corresponding temperature ranges are:
Type 1 = X'01'-Commercial range of 0 to 40 degrees C,
Type 2 = X'02'-Industrial range of -30 to 70 degrees C."
::= { dot11PhyOperationEntry 3 }
dot11RegDomainsSupportValue OBJECT-TYPE
SYNTAX INTEGER {fcc(16), doc(32), etsi(48), spain (49), france
(50), mkk (64) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"There are different operational requirements dependent on
the regulatory domain. This attribute list describes the
regulatory domains the PLCP and PMD support in this
implementation. Currently de- fined values and their
corresponding Regulatory Domains are:
FCC (USA) = X'10', DOC (Canada) = X'20', ETSI (most of
Europe) = X'30', Spain = X'31', France = X'32', MKK
(Japan) = X'40' "
::= { dot11PhyOperationEntry 4 }
dot11SupportedDataRatesTxValue OBJECT-TYPE
SYNTAX Integer32 (2..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Transmit bit rates supported by the PLCP and PMD,
represented by a count from X?2-X?f, corresponding to data
rates in increments of 500Kb/s from 1 Mb/s to 63.5 Mb/s subject
to limitations of each individual PHY."
::= { dot11PhyOperationEntry 5 }
dot11SupportedDataRatesRxValue OBJECT-TYPE
SYNTAX Integer32 (2..127)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The receive bit rates supported by the PLCP and PMD,
represented by a count from X?2-X?f, corresponding to data
rates in increments of 500Kb/s from 1 Mb/s to 63.5 Mb/s."
::= { dot11PhyOperationEntry 6 }
dot11CurrentTxRate OBJECT-TYPE
SYNTAX INTEGER (2..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current tx operating rate. corresponding to data
rates in increments of 500Kb/s from 1 Mb/s to 63.5 Mb/s."
::= { dot11PhyOperationEntry 7 }
dot11ChannelAgilityPresent OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates that the PHY is capable of channel agility."
::= { dot11PhyOperationEntry 8 }
dot11ChannelAgilityEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates that the PHY channel agility
functionality is enabled."
::= { dot11PhyOperationEntry 9 }
-- **********************************************************************
-- * End of dot11PhyOperation TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11PhyAntenna TABLE
-- **********************************************************************
dot11CurrentTxAntenna OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current antenna being used to transmit. This value
is one of the values appearing in
dot11SupportedTxAntenna. This may be used by a management agent to control which antenna is used for transmission. "
::= { dot11PhyAntennaEntry 1 }
dot11DiversitySupport OBJECT-TYPE
SYNTAX INTEGER {fixedlist(1), notsupported(2), dynamic(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This implementation's support for diversity, encoded as:
X'01'-diversity is available and is performed over the fixed
list of antennas defined in dot11DiversitySelectionRx.
X'02'-diversity is not supported.
X'03'-diversity is supported and control of diversity is also
available, in which case the attribute
dot11DiversitySelectionRx can be dynamically modified by the
LME."
::= { dot11PhyAntennaEntry 2 }
dot11CurrentRxAntenna OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current antenna being used to receive, if the dot11 DiversitySupport indicates that diversity is not supported. The selected antenna shall be one of the antennae marked for receive in the dot11AntennasListTable. "
::= { dot11PhyAntennaEntry 3 }
-- **********************************************************************
-- * End of dot11PhyAntenna TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11PhyTxPower TABLE
-- **********************************************************************
dot11NumberSupportedPowerLevels OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of power levels supported by the PMD.
This attribute can have a value of 1 to 8."
::= { dot11PhyTxPowerEntry 1 }
dot11TxPowerLevel1 OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit output power for LEVEL1 in mW.
This is also the default power level."
::= { dot11PhyTxPowerEntry 2 }
dot11TxPowerLevel2 OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit output power for LEVEL2 in mW."
::= { dot11PhyTxPowerEntry 3 }
dot11TxPowerLevel3 OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit output power for LEVEL3 in mW."
::= { dot11PhyTxPowerEntry 4 }
dot11TxPowerLevel4 OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit output power for LEVEL4 in mW."
::= { dot11PhyTxPowerEntry 5 }
dot11TxPowerLevel5 OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit output power for LEVEL5 in mW."
::= { dot11PhyTxPowerEntry 6 }
dot11TxPowerLevel6 OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit output power for LEVEL6 in mW."
::= { dot11PhyTxPowerEntry 7 }
dot11TxPowerLevel7 OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit output power for LEVEL7 in mW."
::= { dot11PhyTxPowerEntry 8 }
dot11TxPowerLevel8 OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmit output power for LEVEL8 in mW."
::= { dot11PhyTxPowerEntry 9 }
dot11CurrentTxPowerLevel OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The TxPowerLevel N currently being used to transmit data.
Some PHYs also use this value to determine the receiver
sensitivity requirements for CCA."
::= { dot11PhyTxPowerEntry 10 }
-- **********************************************************************
-- * End of dot11PhyTxPower TABLE
-- **********************************************************************
-- **********************************************************************
-- * dot11PhyDSSSEntry TABLE
-- **********************************************************************
dot11CurrentChannel OBJECT-TYPE
SYNTAX INTEGER (1..14)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current operating frequency channel of the DSSS
PHY. Valid channel numbers are as defined in 15.4.6.2"
::= { dot11PhyDSSSEntry 1 }
dot11DynamicChannelEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicate dynamic channel is enabled."
::= { dot11PhyDSSSEntry 2 }
dot11CCAModeSupported OBJECT-TYPE
SYNTAX INTEGER (1..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"dot11CCAModeSupported is a bit-significant value, representing all of the CCA modes supported by the PHY. Valid values are:
energy detect only (ED_ONLY) = 01,
carrier sense only (CS_ONLY) = 02,
carrier sense and energy detect (ED_and_CS)= 04
or the logical sum of any of these values."
::= { dot11PhyDSSSEntry 3 }
dot11CurrentCCAMode OBJECT-TYPE
SYNTAX INTEGER {edonly(1), csonly(2), edandcs(4)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current CCA method in operation. Valid values are:
energy detect only (edonly) = 01,
carrier sense only (csonly) = 02,
carrier sense and energy detect (edandcs)= 04."
::= { dot11PhyDSSSEntry 4 }
dot11EDThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current Energy Detect Threshold being used by the DSSS PHY."
::= { dot11PhyDSSSEntry 5 }
dot11ShortPreambleOptionImplemented OBJECT-TYPE
SYNTAX INTEGER {true(1), false(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute, when true, shall indicate that the short
preamble option as deTned in subclause 18.2.2.2 is implemented.
The default value of this attribute shall be false."
::= { dot11PhyDSSSEntry 6 }
dot11PBCCOptionImplemented OBJECT-TYPE
SYNTAX INTEGER {true(1), false(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute, when true, shall indicate that the PBCC modulation
option as defined in subclause 18.4.6.6 is implemented. The default
value of this attribute shall be false."
::= { dot11PhyDSSSEntry 7 }
-- **********************************************************************
-- * End of dot11PhyDSSSEntry TABLE
-- **********************************************************************
-- **********************************************************************
-- * End of 80211 MIB
-- **********************************************************************
END