206 lines
7.7 KiB
Plaintext
206 lines
7.7 KiB
Plaintext
-- *****************************************************************
|
|
-- NMS-EPON-OLT-PON-EXT.MIB: NMS OLT-COMM MIB file
|
|
-- AUG 2009
|
|
-- *****************************************************************
|
|
--
|
|
|
|
NMS-EPON-OLT-PON-EXT DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Counter, IpAddress, Counter
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString, ifIndex, PhysAddress
|
|
FROM RFC1213-MIB
|
|
nmsEPONGroup
|
|
FROM NMS-SMI
|
|
RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
--ponOpticsParameterTable
|
|
ponOpticsParameterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PonOpticsParameterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of epon olt pon optical property table entries."
|
|
::= { nmsEPONGroup 107 }
|
|
|
|
ponOpticsParameterEntry OBJECT-TYPE
|
|
SYNTAX PonOpticsParameterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A collection of additional objects in the
|
|
epon olt pon optical property table."
|
|
INDEX { ponIfIndex }
|
|
::= { ponOpticsParameterTable 1 }
|
|
|
|
PonOpticsParameterEntry ::=
|
|
SEQUENCE {
|
|
ponIfIndex
|
|
INTEGER,
|
|
linkStatus
|
|
INTEGER,
|
|
txPower
|
|
INTEGER,
|
|
txPowerUpLimit
|
|
INTEGER,
|
|
txPowerLowLimit
|
|
INTEGER,
|
|
temperature
|
|
INTEGER,
|
|
vlotage
|
|
INTEGER,
|
|
curr
|
|
INTEGER
|
|
}
|
|
|
|
ponIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The only diid of PON port in System."
|
|
::= { ponOpticsParameterEntry 1 }
|
|
|
|
linkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
link-up(1),
|
|
link-down(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The link status of interface. 1-link up, 2-link down."
|
|
::= { ponOpticsParameterEntry 2 }
|
|
|
|
txPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The tx power of optical module. The unit is 0.1DBm."
|
|
::= { ponOpticsParameterEntry 3 }
|
|
|
|
txPowerUpLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The upper threshold of tx power alarm. The unit is 0.1DBm."
|
|
::= { ponOpticsParameterEntry 4 }
|
|
|
|
txPowerLowLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low threshold of tx power alarm. The unit is 0.1DBm."
|
|
::= { ponOpticsParameterEntry 5 }
|
|
|
|
temperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Optical module temperature. The unit is 1/256 degree."
|
|
::= { ponOpticsParameterEntry 6 }
|
|
|
|
vlotage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Optical module volt. The unit is 0.1mV."
|
|
::= { ponOpticsParameterEntry 7 }
|
|
|
|
curr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Optical module bias current. The unit is 2mA."
|
|
::= { ponOpticsParameterEntry 8 }
|
|
|
|
|
|
|
|
--ponOpticsRxPowerTable
|
|
ponOpticsRxPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PonOpticsRxPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of epon olt pon optical Rx Power table entries."
|
|
::= { nmsEPONGroup 108 }
|
|
|
|
ponOpticsRxPowerEntry OBJECT-TYPE
|
|
SYNTAX PonOpticsRxPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A collection of additional objects in the
|
|
epon olt pon optical Rx Power property table."
|
|
INDEX { onuIfIndex }
|
|
::= { ponOpticsRxPowerTable 1 }
|
|
|
|
PonOpticsRxPowerEntry ::=
|
|
SEQUENCE {
|
|
onuIfIndex
|
|
INTEGER,
|
|
onuLinkStatus
|
|
INTEGER,
|
|
rxPower
|
|
INTEGER,
|
|
rxPowerUpLimit
|
|
INTEGER,
|
|
rxPowerLowLimit
|
|
INTEGER
|
|
}
|
|
|
|
onuIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The only diid of PON port in System."
|
|
::= { ponOpticsRxPowerEntry 1 }
|
|
|
|
onuLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
link-up(1),
|
|
link-down(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The link status of onu. 1-link up, 2-link down."
|
|
::= { ponOpticsRxPowerEntry 2 }
|
|
|
|
rxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rx power of optical module. The unit is 0.1DBm."
|
|
::= { ponOpticsRxPowerEntry 3 }
|
|
|
|
rxPowerUpLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The upper threshold of rx power alarm. The unit is 0.1DBm."
|
|
::= { ponOpticsRxPowerEntry 4 }
|
|
|
|
rxPowerLowLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low threshold of rx power alarm. The unit is 0.1DBm."
|
|
::= { ponOpticsRxPowerEntry 5 }
|
|
|
|
|
|
END |