-- BDCOM-FLASH.my: BDCom Flash MIB file
|
|
--
|
|
--
|
|
-- *****************************************************************
|
|
--
|
|
|
|
BDCOM-FLASH DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
TimeTicks
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
bdlocal
|
|
FROM BDCOM-SMI;
|
|
|
|
bdlflash OBJECT IDENTIFIER ::= { bdlocal 10 }
|
|
|
|
|
|
-- This group is present in all products which contain flash"
|
|
|
|
bdflashSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total Size in Octets of Flash memory"
|
|
::= { bdlflash 1 }
|
|
|
|
bdflashFree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unused Size in Octets of Flash memory"
|
|
::= { bdlflash 2 }
|
|
|
|
bdflashController OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Provides the type of Flash controller
|
|
(either CCTL or CCTL2) installed in the
|
|
router."
|
|
::= { bdlflash 3 }
|
|
|
|
bdflashCard OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Provides the type of Flash Card installed
|
|
in the router. For example, the type of
|
|
Flash Card could be either CSC-MS or
|
|
CSC-MC+."
|
|
::= { bdlflash 4 }
|
|
|
|
bdflashVPP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
installed(1),
|
|
missing(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the VPP DIP jumper on the Flash
|
|
memory card. Files can be written to the
|
|
Flash memory card only if the VPP DIP
|
|
jumper is turned on."
|
|
::= { bdlflash 5 }
|
|
|
|
bdflashErase OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Request to erase flash memory"
|
|
::= { bdlflash 6 }
|
|
|
|
bdflashEraseTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the value of sysUptime the last
|
|
time Flash memory was erased. If the flash
|
|
had not been erased after powerup it has a
|
|
value of 0 days 00:00:00."
|
|
::= { bdlflash 7 }
|
|
|
|
bdflashEraseStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
flashOpInProgress(1),
|
|
flashOpSuccess(2),
|
|
flashOpFailure(3),
|
|
flashReadOnly(4),
|
|
flashOpenFailure(5),
|
|
bufferAllocationFailure(6),
|
|
noOpAfterPowerOn(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of current or last flash erasing"
|
|
::= { bdlflash 8 }
|
|
|
|
bdflashToNet OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Write flash entry to tftp server. Value
|
|
should be the name of the flash entry to
|
|
send. Instance is the IP address of the tftp
|
|
host."
|
|
::= { bdlflash 9 }
|
|
|
|
bdflashToNetTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the value of sysUpTime the last
|
|
time a file was transfered from Flash memory
|
|
on the router to a TFTP host. Returns
|
|
0 days 00:00:00 if there had been no transfer
|
|
since powerup."
|
|
::= { bdlflash 10 }
|
|
|
|
bdflashToNetStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
flashOpInProgress(1),
|
|
flashOpSuccess(2),
|
|
flashOpFailure(3),
|
|
flashReadOnly(4),
|
|
flashOpenFailure(5),
|
|
bufferAllocationFailure(6),
|
|
noOpAfterPowerOn(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of current or last flash to net
|
|
transfer"
|
|
::= { bdlflash 11 }
|
|
|
|
bdnetToFlash OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Write flash entry from tftp server. Value
|
|
should be the name of the flash entry to
|
|
write. Instance is the IP address of the tftp
|
|
host."
|
|
::= { bdlflash 12 }
|
|
|
|
bdnetToFlashTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the value of sysUpTime the last
|
|
time file was copied from a Trivial File
|
|
Transfer Protocol(TFTP) server to the Flash
|
|
memory on the router. Returns 0 days 00:00:00
|
|
if there had been no transfers since powerup."
|
|
::= { bdlflash 13 }
|
|
|
|
bdnetToFlashStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
flashOpInProgress(1),
|
|
flashOpSuccess(2),
|
|
flashOpFailure(3),
|
|
flashReadOnly(4),
|
|
flashOpenFailure(5),
|
|
bufferAllocationFailure(6),
|
|
noOpAfterPowerOn(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of current or last net to flash
|
|
transfer"
|
|
::= { bdlflash 14 }
|
|
|
|
bdflashStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
busy(1),
|
|
available(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of the availability of flash"
|
|
::= { bdlflash 15 }
|
|
|
|
bdflashEntries OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the flash directory"
|
|
::= { bdlflash 16 }
|
|
|
|
|
|
-- Local Flash file Table
|
|
|
|
-- This group contains information on a per file basis
|
|
|
|
bdlflashFileDirTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BdLflashFileDirEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" A list of flash file entries."
|
|
::= { bdlflash 17 }
|
|
|
|
bdlflashFileDirEntry OBJECT-TYPE
|
|
SYNTAX BdLflashFileDirEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A collection of flash eprom objects"
|
|
INDEX { flashEntries }
|
|
::= { bdlflashFileDirTable 1 }
|
|
|
|
BdLflashFileDirEntry ::=
|
|
SEQUENCE {
|
|
bdflashDirName
|
|
DisplayString,
|
|
bdflashDirSize
|
|
INTEGER,
|
|
bdflashDirStatus
|
|
INTEGER
|
|
}
|
|
|
|
-- The following section describes the components of the
|
|
-- table.
|
|
|
|
bdflashDirName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name associated with the flash entry"
|
|
::= { bdlflashFileDirEntry 1 }
|
|
|
|
bdflashDirSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Size in Octets of a flash entry"
|
|
::= { bdlflashFileDirEntry 2 }
|
|
|
|
bdflashDirStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
deleted(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the status of the entry"
|
|
::= { bdlflashFileDirEntry 3 }
|
|
|
|
-- End of table
|
|
|
|
|
|
END
|
|
|