Observium_CE/mibs/arris/ARRIS-HOT-PROTECTION-MODE-MIB

104 lines
4.4 KiB
Plaintext

ARRIS-HOT-PROTECTION-MODE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32
FROM SNMPv2-SMI
arrisProdIdCM
FROM ARRIS-MIB;
arrisHorizOvertempProtModeMib MODULE-IDENTITY
LAST-UPDATED "201410010000Z" -- October 1, 2014
ORGANIZATION "ARRIS Broadband"
CONTACT-INFO "ARRIS
Postal: ARRIS Broadband
3871 Lakefield Drive
Suite 300
Suwanee, GA 30024-1242
U.S.A.
Phone:
E-mail: "
DESCRIPTION
"This MIB module supplies the basic management objects for the
Horizontal Over-Temperature feature."
-- Revision history
REVISION "201409050000Z" -- September 05, 2014
DESCRIPTION
"First release of ARRIS Horizontal Over-Temperature Protection Mode MIB."
REVISION "201409240000Z" -- September 24, 2014
DESCRIPTION
"Corrected arrisHorizOvertempProtModeCount SYNTAX and DESCRIPTION, and updated default value
of arrisHorizOvertempProtModeNormalOpRecoveryTemp."
REVISION "201410010000Z" -- October 1, 2014
DESCRIPTION
"Added Counter32 to IMPORTS, modified mib file DESCRIPTION, defined arrisProdIdCM leaf to 16,
and defined a valid range from 15 to 65 for all temperature thresholds"
::= { arrisProdIdCM 16 }
arrisHorizOvertempProtModeMibObjects OBJECT IDENTIFIER ::= { arrisHorizOvertempProtModeMib 1 }
arrisHorizOvertempProtModeMonitoring OBJECT IDENTIFIER ::= { arrisHorizOvertempProtModeMibObjects 1 }
arrisHorizOvertempProtModeConfiguration OBJECT IDENTIFIER ::= { arrisHorizOvertempProtModeMibObjects 2 }
arrisHorizOvertempProtModeState OBJECT-TYPE
SYNTAX INTEGER { normal(1),
thresholdExceededHOTPTier1(2),
thresholdExceededHOTPTier2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the current thermal state. The value 'normal(1)'
indicates the device is operating within the normal
temperature range and not running in Horizontal
Over-Temperature Protection Mode. The value
'thresholdExceededHOTPTier1(2)' indicates the device exceeded
the maximum normal operating temperature and is in Tier 1
Horizontal Over-Temperature Protection Mode. The value
'thresholdExceededHOTPTier2(3)' indicates the device exceeded
the maximum Tier 1 operating temperature and is in
Tier 2 Horizontal Over-Temperature Protection Mode."
::= { arrisHorizOvertempProtModeMonitoring 1 }
arrisHorizOvertempProtModeCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the number of times the device has exceeded the
maximum temperature threshold and gone into Tier2 Horizontal
Over-Temperature Protection Mode. This value is persistent
and only cleared by a restore to factory defaults."
::= { arrisHorizOvertempProtModeMonitoring 2 }
arrisHorizOvertempProtModeTier1MinThreshold OBJECT-TYPE
SYNTAX Integer32 (15..65)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Minimum temperature in Celcius that triggers device to
switch from normal operation to Tier 1 Over-Temperature
Protection Mode operation."
DEFVAL { 37 }
::= { arrisHorizOvertempProtModeConfiguration 1 }
arrisHorizOvertempProtModeTier1MaxThreshold OBJECT-TYPE
SYNTAX Integer32 (15..65)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum temperature in Celcius that the device continues
to operate in Tier 1 Over-Temperature Protection Mode before
switching to Tier 2 Over-Temperature Protection Mode
operation."
DEFVAL { 47 }
::= { arrisHorizOvertempProtModeConfiguration 2 }
arrisHorizOvertempProtModeNormalOpRecoveryTemp OBJECT-TYPE
SYNTAX Integer32 (15..65)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Temperature in Celcius that the device recovers back
to normal operation after being in Tier 1 Over-Temperature
Protection Mode."
DEFVAL { 33 }
::= { arrisHorizOvertempProtModeConfiguration 3 }
END