Files
Observium_CE/mibs/webgraph/WebGraph-AnalogIn-57641-US-MIB

2536 lines
82 KiB
Plaintext

WebGraph-AnalogIn-57641-US-MIB DEFINITIONS ::= BEGIN
----------------------------------------------------------------
-- Revison: 1.29
----------------------------------------------------------------
-- 22.06.2010 Webio
-- Syntax correction
----------------------------------------------------------------
-- Revison: 1.28
----------------------------------------------------------------
-- 02.12.2008 Webio
-- New Graphics java script base parameter
----------------------------------------------------------------
-- Revison: 1.27
----------------------------------------------------------------
-- 09.11.2006 Webio
-- DHCP enable
----------------------------------------------------------------
-- Revison: 1.26
----------------------------------------------------------------
-- 28.06.2006 New: Community String Trap
--
----------------------------------------------------------------
-- Revison: 1.25
----------------------------------------------------------------
-- 25.11.2005 #57641, WebGraph AnalogIn
-- OID correction
----------------------------------------------------------------
-- Revison: 1.24
----------------------------------------------------------------
-- 26.07.2005 #57641, WebGraph AnalogIn
-- CRON timer function
----------------------------------------------------------------
-- Revison: 1.23
----------------------------------------------------------------
-- 14.07.2005 #57641, WebGraph AnalogIn
-- FTP functions
----------------------------------------------------------------
-- Revison: 1.22
----------------------------------------------------------------
-- 17.05.2005 #57641, WebGraph AnalogIn
-- Trap NMS annotations
----------------------------------------------------------------
-- Revison: 1.21
----------------------------------------------------------------
-- 19.04.2005 #57605, WebGraph Themometer
-- Mail Authentication
----------------------------------------------------------------
-- Revison: 1.20
----------------------------------------------------------------
-- 05.11.2004 #57606, WebGraph Thermo-Hygrometer
-- New: Syslog
--
----------------------------------------------------------------
-- Revison: 1.19
----------------------------------------------------------------
-- 08.09.2004 #57606 WebGraph Thermo-Hygrometer
-- New:
-- wtWebGraphThermHygroAlarmRHMin
-- wtWebGraphThermHygroAlarmRHMax
-- wtWebGraphThermHygroAlarmRHHysteresis
-- wtWebGraphThermHygroPortSensorSelect
-- wtWebGraphThermHygroAlarmDeltaTemp
-- wtWebGraphThermHygroAlarmAHMin
-- wtWebGraphThermHygroAlarmAHMax
----------------------------------------------------------------
-- Revison: 1.18
----------------------------------------------------------------
-- 21.07.2004 #57601/3/4, Webio Anx
-- New:
-- Diagnosis
----------------------------------------------------------------
-- Revison: 1.17
----------------------------------------------------------------
-- 28.06.2004 #57630/1/2, Webio Digital
-- Neu: Puls Mode
----------------------------------------------------------------
-- Revison: 1.16
----------------------------------------------------------------
-- 16.04.2004 New: #57632, Webio Digital EA24x24
--
-- #57630/1, Webio Digital EA12x12
-- New:
-- wtWebioEA12x12InputCounterClear
----------------------------------------------------------------
-- Revison: 1.15
----------------------------------------------------------------
-- 27.02.2004 #57630/1, Webio Digital EA12x12
-- New:
-- Length changed to 32 Bit:
-- wtWebioEA12x12InputValue
-- wtWebioEA12x12OutputValue
-- wtWebioEA12x12LoadControlView
-- wtWebioEA12x12LCShutDownView
-- wtWebioEA12x12SetOutput
-- wtWebioEA12x12AlarmInputTrigger
-- wtWebioEA12x12AlarmOutputTrigger
-- wtWebioEA12x12PortOutputSafetyState
----------------------------------------------------------------
-- Revison: 1.14
----------------------------------------------------------------
-- 16.02.2004 #57630/1, Webio Digital EA12x12
-- New:
-- Text: Location, Contact
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
-- Alarm: ColdStart / WarmStart trigger
--
-- #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New:
-- Alarm Hysteresis
-- Alarm Clear Traps and Mails
----------------------------------------------------------------
-- Revison: 1.13
----------------------------------------------------------------
-- 05.02.2004 #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New:
-- Text: Location, Contact
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
-- Alarm: ColdStart / WarmStart trigger
----------------------------------------------------------------
-- Revison: 1.12
----------------------------------------------------------------
-- 05.11.2003 #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New features:
-- Mail : Option CSV attachment
-- Port : Offset calibration
-- Alarm : TCP Client mode
----------------------------------------------------------------
-- Revison: 1.11
----------------------------------------------------------------
-- 28.10.2003 #57630/1, Webio Digital EA12x12
-- New features:
-- Alarm : TCP Client mode
-- Inputs: Puls filter
----------------------------------------------------------------
-- Revison: 1.10
----------------------------------------------------------------
-- 22.07.2003 #57630, Webio Digital EA12x12
-- New navigation tree, new binary modes
--
----------------------------------------------------------------
-- Revison: 1.09
----------------------------------------------------------------
-- 24.03.2003 Trap Enterprise (Type 1, 2) corrected
----------------------------------------------------------------
-- Revison: 1.08
----------------------------------------------------------------
-- 04.03.2003 reconciled the language versions DE/US
----------------------------------------------------------------
-- Revison: 1.07
----------------------------------------------------------------
-- 25.02.2003 Correction: wtWebioEA12x12LoadControl
----------------------------------------------------------------
-- Revison: 1.06
----------------------------------------------------------------
-- 24.02.2003 New:
-- #57630, Webio EA12x12, LoadControl Group
-- Correction: Trap variable names
----------------------------------------------------------------
-- Revison: 1.05
----------------------------------------------------------------
-- 21.01.2003 New:
-- #57630, Webio EA12x12
----------------------------------------------------------------
-- Revison: 1.04
----------------------------------------------------------------
-- 02.01.2003 New:
-- #57601, 1xWebThermometer
-- #57603, 2xWebThermometer, 8 alarms
----------------------------------------------------------------
-- Revison: 1.03
----------------------------------------------------------------
-- 21.11.2002 New:
-- #57604, 2xWebThermometer, BOOTP, StartupSite
-- #57603, 8xWebThermometer, BOOTP, StartupSite
----------------------------------------------------------------
-- Revison: 1.02
----------------------------------------------------------------
-- 26.07.2002 New:
-- #57604, 2xWebThermometer
-- #57603, 8xWebThermometer
--
IMPORTS
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
DisplayString, PhysAddress FROM RFC1213-MIB
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
-- IpAddress ::=
-- [APPLICATION 0]
-- IMPLICIT OCTET STRING (SIZE (4))
-- Counter ::=
-- [APPLICATION 1]
-- IMPLICIT INTEGER (0..4294967295)
-- Gauge ::=
-- [APPLICATION 2]
-- IMPLICIT INTEGER (0..4294967295)
-- TimeTicks ::=
-- [APPLICATION 3]
-- IMPLICIT INTEGER (0..4294967295)
-- DisplayString ::= OCTET STRING
-- PhysAddress ::= OCTET STRING
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
-- privat OBJECT IDENTIFIER ::= { internet 4 }
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
-- Wiesemann & Theis Com-Server MIB
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
-- wtWebGraph Tree
wtWebGraphAnalogIn57641 OBJECT IDENTIFIER ::= { wtWebio 10 }
-- wtWebGraphAnalogIn57641 Tree
wtWebGraphAnalogIn57641Inventory OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641 1 }
wtWebGraphAnalogIn57641SessCntrl OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641 2 }
wtWebGraphAnalogIn57641Config OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641 3 }
wtWebGraphAnalogIn57641Diag OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641 4 }
-- wtWebGraphAnalogIn57641Config Tree
wtWebGraphAnalogIn57641Device OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Config 1 }
wtWebGraphAnalogIn57641Ports OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Config 2 }
wtWebGraphAnalogIn57641Manufact OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Config 3 }
-- wtWebGraphAnalogIn57641Device Tree
wtWebGraphAnalogIn57641Text OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Device 1 }
wtWebGraphAnalogIn57641TimeDate OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Device 2 }
wtWebGraphAnalogIn57641Basic OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Device 3 }
wtWebGraphAnalogIn57641Datalogger OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Device 4 }
wtWebGraphAnalogIn57641Alarm OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Device 5 }
wtWebGraphAnalogIn57641Graphics OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Device 6 }
-- wtWebGraphAnalogIn57641TimeDate Tree
wtWebGraphAnalogIn57641TimeZone OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641TimeDate 1 }
wtWebGraphAnalogIn57641TimeServer OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641TimeDate 2 }
wtWebGraphAnalogIn57641DeviceClock OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641TimeDate 3 }
-- wtWebGraphAnalogIn57641Basic Tree
wtWebGraphAnalogIn57641Network OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Basic 1 }
wtWebGraphAnalogIn57641HTTP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Basic 2 }
wtWebGraphAnalogIn57641Mail OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Basic 3 }
wtWebGraphAnalogIn57641SNMP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Basic 4 }
wtWebGraphAnalogIn57641UDP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Basic 5 }
wtWebGraphAnalogIn57641Syslog OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Basic 6 }
wtWebGraphAnalogIn57641FTP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Basic 7 }
-- wtWebGraphAnalogIn57641Graphics Tree
wtWebGraphAnalogIn57641GraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Graphics 1 }
wtWebGraphAnalogIn57641GraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Graphics 2 }
wtWebGraphAnalogIn57641GraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57641Graphics 3 }
-- wtWebGraphAnalogIn57641Inventory Group
------------------------
wtWebGraphAnalogIn57641Sensors OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of sensors"
::= { wtWebGraphAnalogIn57641Inventory 1 }
-- Interface Table
wtWebGraphAnalogIn57641SensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57641SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensors."
::= { wtWebGraphAnalogIn57641Inventory 2 }
wtWebGraphAnalogIn57641SensorEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57641SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensor numbers."
INDEX { wtWebGraphAnalogIn57641SensorNo }
::= { wtWebGraphAnalogIn57641SensorTable 1 }
WtWebGraphAnalogIn57641SensorEntry ::= SEQUENCE {
wtWebGraphAnalogIn57641SensorNo INTEGER
}
wtWebGraphAnalogIn57641SensorNo OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sensor number."
::= { wtWebGraphAnalogIn57641SensorEntry 1 }
-- wtWebGraphAnalogIn57641Values Table
wtWebGraphAnalogIn57641ValuesTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57641ValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of measurement values corresponding to the channel numbers."
::= { wtWebGraphAnalogIn57641Inventory 3 }
wtWebGraphAnalogIn57641ValuesEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57641ValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Measurement values of the sensors."
INDEX { wtWebGraphAnalogIn57641SensorNo }
::= { wtWebGraphAnalogIn57641ValuesTable 1 }
WtWebGraphAnalogIn57641ValuesEntry ::= SEQUENCE{
wtWebGraphAnalogIn57641Values OCTET STRING
}
wtWebGraphAnalogIn57641Values OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Measurement value of the sensor, ASCII, 7 characters in length."
::= { wtWebGraphAnalogIn57641ValuesEntry 1 }
-- wtWebGraphAnalogIn57641BinaryValues Table
wtWebGraphAnalogIn57641BinaryValuesTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57641BinaryValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of binary measurement values corresponding to the channel numbers."
::= { wtWebGraphAnalogIn57641Inventory 4 }
wtWebGraphAnalogIn57641BinaryValuesEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57641BinaryValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Binary measurement values of the sensors."
INDEX { wtWebGraphAnalogIn57641SensorNo }
::= { wtWebGraphAnalogIn57641BinaryValuesTable 1 }
WtWebGraphAnalogIn57641BinaryValuesEntry ::= SEQUENCE{
wtWebGraphAnalogIn57641BinaryValues INTEGER
}
wtWebGraphAnalogIn57641BinaryValues OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent,
signed number, 0x4FFF6 indicates an
invalid measured value."
::= { wtWebGraphAnalogIn57641BinaryValuesEntry 1 }
-- wtWebGraphAnalogIn57641SessCntrl Group
--------------------------------
wtWebGraphAnalogIn57641SessCntrlPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Entering this password opens a session which is ended by writing a 1 to
wtWebGraphAnalogIn57641SessCntrlLogout. When read this variable provides a string of
length zero."
::= { wtWebGraphAnalogIn57641SessCntrl 1 }
wtWebGraphAnalogIn57641SessCntrlConfigMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641SessCntrl-NoSession(0),
wtWebGraphAnalogIn57641SessCntrl-Session(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When the device is in SNMP configuration mode, the value 1 is
returned, otherwise 0. If the read value is 0 even though the
password was written, the device is already in config mode and the
variables can only be read."
::= { wtWebGraphAnalogIn57641SessCntrl 2 }
wtWebGraphAnalogIn57641SessCntrlLogout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session
and all parameters are stored.
Writing a 2 discards all entries again.
When read this variable provides the value 0."
::= { wtWebGraphAnalogIn57641SessCntrl 3 }
wtWebGraphAnalogIn57641SessCntrlAdminPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public."
::= { wtWebGraphAnalogIn57641SessCntrl 4 }
wtWebGraphAnalogIn57641SessCntrlConfigPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid password is public. When read this variable provides a null-pointer."
::= { wtWebGraphAnalogIn57641SessCntrl 5 }
-- wtWebGraphAnalogIn57641Text Group
------------------------
wtWebGraphAnalogIn57641DeviceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the Webio, which is user definable."
::= { wtWebGraphAnalogIn57641Text 1 }
wtWebGraphAnalogIn57641DeviceText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the Webio, which is user definable."
::= { wtWebGraphAnalogIn57641Text 2 }
wtWebGraphAnalogIn57641DeviceLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the location of the Webio, which is user definable."
::= { wtWebGraphAnalogIn57641Text 3 }
wtWebGraphAnalogIn57641DeviceContact OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Contact address of the system operator of the Webio, which is user definable."
::= { wtWebGraphAnalogIn57641Text 4 }
-- wtWebGraphAnalogIn57641TimeZone Group
----------------------------
wtWebGraphAnalogIn57641TzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours for the time zone (winter time) with respect to UTC."
::= { wtWebGraphAnalogIn57641TimeZone 1 }
wtWebGraphAnalogIn57641TzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes for the time zone (winter time) with respect to UTC."
::= { wtWebGraphAnalogIn57641TimeZone 2 }
wtWebGraphAnalogIn57641TzEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Timezone"
::= { wtWebGraphAnalogIn57641TimeZone 3 }
wtWebGraphAnalogIn57641StTzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours of the time zone (summer time) with respect to UTC."
::= { wtWebGraphAnalogIn57641TimeZone 4 }
wtWebGraphAnalogIn57641StTzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes of the time zone (summer time) with respect to UTC."
::= { wtWebGraphAnalogIn57641TimeZone 5 }
wtWebGraphAnalogIn57641StTzEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Summertime"
::= { wtWebGraphAnalogIn57641TimeZone 6 }
wtWebGraphAnalogIn57641StTzStartMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641StartMonth-January(1),
wtWebGraphAnalogIn57641StartMonth-February(2),
wtWebGraphAnalogIn57641StartMonth-March(3),
wtWebGraphAnalogIn57641StartMonth-April(4),
wtWebGraphAnalogIn57641StartMonth-May(5),
wtWebGraphAnalogIn57641StartMonth-June(6),
wtWebGraphAnalogIn57641StartMonth-July(7),
wtWebGraphAnalogIn57641StartMonth-August(8),
wtWebGraphAnalogIn57641StartMonth-September(9),
wtWebGraphAnalogIn57641StartMonth-October(10),
wtWebGraphAnalogIn57641StartMonth-November(11),
wtWebGraphAnalogIn57641StartMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from winter time to summer time."
::= { wtWebGraphAnalogIn57641TimeZone 7 }
wtWebGraphAnalogIn57641StTzStartMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641StartMode-first(1),
wtWebGraphAnalogIn57641StartMode-second(2),
wtWebGraphAnalogIn57641StartMode-third(3),
wtWebGraphAnalogIn57641StartMode-fourth(4),
wtWebGraphAnalogIn57641StartMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the day of the week for which the change is made from winter time to summer time."
::= { wtWebGraphAnalogIn57641TimeZone 8 }
wtWebGraphAnalogIn57641StTzStartWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641StartWday-Sunday(1),
wtWebGraphAnalogIn57641StartWday-Monday(2),
wtWebGraphAnalogIn57641StartWday-Tuesday(3),
wtWebGraphAnalogIn57641StartWday-Thursday(4),
wtWebGraphAnalogIn57641StartWday-Wednesday(5),
wtWebGraphAnalogIn57641StartWday-Friday(6),
wtWebGraphAnalogIn57641StartWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from winter time to summer time"
::= { wtWebGraphAnalogIn57641TimeZone 9 }
wtWebGraphAnalogIn57641StTzStartHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebGraphAnalogIn57641TimeZone 10 }
wtWebGraphAnalogIn57641StTzStartMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebGraphAnalogIn57641TimeZone 11 }
wtWebGraphAnalogIn57641StTzStopMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641StopMonth-January(1),
wtWebGraphAnalogIn57641StopMonth-February(2),
wtWebGraphAnalogIn57641StopMonth-March(3),
wtWebGraphAnalogIn57641StopMonth-April(4),
wtWebGraphAnalogIn57641StopMonth-May(5),
wtWebGraphAnalogIn57641StopMonth-June(6),
wtWebGraphAnalogIn57641StopMonth-July(7),
wtWebGraphAnalogIn57641StopMonth-August(8),
wtWebGraphAnalogIn57641StopMonth-September(9),
wtWebGraphAnalogIn57641StopMonth-October(10),
wtWebGraphAnalogIn57641StopMonth-November(11),
wtWebGraphAnalogIn57641StopMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from summer time to winter time."
::= { wtWebGraphAnalogIn57641TimeZone 12 }
wtWebGraphAnalogIn57641StTzStopMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641StopMode-first(1),
wtWebGraphAnalogIn57641StopMode-second(2),
wtWebGraphAnalogIn57641StopMode-third(3),
wtWebGraphAnalogIn57641StopMode-fourth(4),
wtWebGraphAnalogIn57641StopMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the week day on which the change is made from summer time to winter time."
::= { wtWebGraphAnalogIn57641TimeZone 13 }
wtWebGraphAnalogIn57641StTzStopWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641StopWday-Sunday(1),
wtWebGraphAnalogIn57641StopWday-Monday(2),
wtWebGraphAnalogIn57641StopWday-Tuesday(3),
wtWebGraphAnalogIn57641StopWday-Thursday(4),
wtWebGraphAnalogIn57641StopWday-Wednesday(5),
wtWebGraphAnalogIn57641StopWday-Friday(6),
wtWebGraphAnalogIn57641StopWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from summer time to winter time."
::= { wtWebGraphAnalogIn57641TimeZone 14 }
wtWebGraphAnalogIn57641StTzStopHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebGraphAnalogIn57641TimeZone 15 }
wtWebGraphAnalogIn57641StTzStopMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebGraphAnalogIn57641TimeZone 16 }
-- wtWebGraphAnalogIn57641TimeServer Group
----------------------------
wtWebGraphAnalogIn57641TimeServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 1st time server in ASCII"
::= { wtWebGraphAnalogIn57641TimeServer 1 }
wtWebGraphAnalogIn57641TimeServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 2nd time server in ASCII"
::= { wtWebGraphAnalogIn57641TimeServer 2 }
wtWebGraphAnalogIn57641TsEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Time Server"
::= { wtWebGraphAnalogIn57641TimeServer 3 }
wtWebGraphAnalogIn57641TsSyncTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daily synchronisation time with the time server (hour: 0-23)."
::= { wtWebGraphAnalogIn57641TimeServer 4 }
-- wtWebGraphAnalogIn57641DeviceClock Group
----------------------------
wtWebGraphAnalogIn57641ClockHrs OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock hours taking into account the time zone settings."
::= { wtWebGraphAnalogIn57641DeviceClock 1 }
wtWebGraphAnalogIn57641ClockMin OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock minutes taking into account the time zone settings."
::= { wtWebGraphAnalogIn57641DeviceClock 2 }
wtWebGraphAnalogIn57641ClockDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Day of the month, taking into account the time zone settings."
::= { wtWebGraphAnalogIn57641DeviceClock 3 }
wtWebGraphAnalogIn57641ClockMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641ClockMonth-January(1),
wtWebGraphAnalogIn57641ClockMonth-February(2),
wtWebGraphAnalogIn57641ClockMonth-March(3),
wtWebGraphAnalogIn57641ClockMonth-April(4),
wtWebGraphAnalogIn57641ClockMonth-May(5),
wtWebGraphAnalogIn57641ClockMonth-June(6),
wtWebGraphAnalogIn57641ClockMonth-July(7),
wtWebGraphAnalogIn57641ClockMonth-August(8),
wtWebGraphAnalogIn57641ClockMonth-September(9),
wtWebGraphAnalogIn57641ClockMonth-October(10),
wtWebGraphAnalogIn57641ClockMonth-November(11),
wtWebGraphAnalogIn57641ClockMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Month, taking into account the time zone settings."
::= { wtWebGraphAnalogIn57641DeviceClock 4 }
wtWebGraphAnalogIn57641ClockYear OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Year, taking into account the time zone settings."
::= { wtWebGraphAnalogIn57641DeviceClock 5 }
-- wtWebGraphAnalogIn57641Network Group
------------------------
wtWebGraphAnalogIn57641IpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the Webio"
::= { wtWebGraphAnalogIn57641Network 1 }
wtWebGraphAnalogIn57641SubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subnet mask of the Webio"
::= { wtWebGraphAnalogIn57641Network 2 }
wtWebGraphAnalogIn57641Gateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway of the Webio"
::= { wtWebGraphAnalogIn57641Network 3 }
wtWebGraphAnalogIn57641DnsServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 1st DNS server in ASCII"
::= { wtWebGraphAnalogIn57641Network 4 }
wtWebGraphAnalogIn57641DnsServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 2nd DNS server in ASCII"
::= { wtWebGraphAnalogIn57641Network 5 }
wtWebGraphAnalogIn57641AddConfig OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Additional configuration (1=ON):
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: DHCP disable
Bit 0: BOOTP disable
"
::= { wtWebGraphAnalogIn57641Network 6 }
-- wtWebGraphAnalogIn57641HTTP Group
--------------------------------
wtWebGraphAnalogIn57641Startup OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded start page:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: Index.htm
Bit 2: Home.htm
Bit 3: User.htm
Only one page may be selected at a time."
::= { wtWebGraphAnalogIn57641HTTP 1 }
wtWebGraphAnalogIn57641GetHeaderEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If these bits are set, every answer of a short form GET question will be lead
by the IP-address and name of the device and/or a HTTP header:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-6: unused
Bit 1 : GET HTTP enable
Bit 0 : GET Header enable"
::= { wtWebGraphAnalogIn57641HTTP 2 }
wtWebGraphAnalogIn57641HttpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Definition of the standard HTML port (Default: 80)."
::= { wtWebGraphAnalogIn57641HTTP 3 }
-- wtWebGraphAnalogIn57641Mail Group
--------------------------------
wtWebGraphAnalogIn57641MailAdName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Device name for mail administration."
::= { wtWebGraphAnalogIn57641Mail 1 }
wtWebGraphAnalogIn57641MailReply OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reply address for the mail server."
::= { wtWebGraphAnalogIn57641Mail 2 }
wtWebGraphAnalogIn57641MailServer OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the mail server."
::= { wtWebGraphAnalogIn57641Mail 3 }
wtWebioAn1MailEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this bit to enable the sending of mails:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Mail enable"
::= { wtWebGraphAnalogIn57641Mail 4 }
wtWebGraphAnalogIn57641MailAuthentication OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selection of the authentication modi:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : POP3 before SMTP
Bit 1 : ESMTP, authentication
Bit 0 : SMTP, no authentication"
::= { wtWebGraphAnalogIn57641Mail 5 }
wtWebGraphAnalogIn57641MailAuthUser OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the user to be authenticated."
::= { wtWebGraphAnalogIn57641Mail 6 }
wtWebGraphAnalogIn57641MailAuthPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication password."
::= { wtWebGraphAnalogIn57641Mail 7 }
wtWebGraphAnalogIn57641MailPop3Server OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or Ip-address of the POP3 Servers."
::= { wtWebGraphAnalogIn57641Mail 8 }
-- wtWebGraphAnalogIn57641SNMP Group
--------------------------------
wtWebGraphAnalogIn57641SnmpCommunityStringRead OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read only"
::= { wtWebGraphAnalogIn57641SNMP 1 }
wtWebGraphAnalogIn57641SnmpCommunityStringReadWrite OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read / write"
::= { wtWebGraphAnalogIn57641SNMP 2 }
wtWebGraphAnalogIn57641SystemTrapManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the system trap."
::= { wtWebGraphAnalogIn57641SNMP 3 }
wtWebGraphAnalogIn57641SystemTrapEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57641SNMP 4 }
wtWebGraphAnalogIn57641SnmpEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set bit 0 to enable SNMP.
If disabled, the device did not respond to any SNMP requests.
Bit 1 decided wether the community string of read operations
is compared with the system password or not:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : SNMP enable"
::= { wtWebGraphAnalogIn57641SNMP 5 }
wtWebGraphAnalogIn57641SnmpCommunityStringTrap OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string send within traps."
::= { wtWebGraphAnalogIn57641SNMP 6 }
-- wtWebGraphAnalogIn57641UDP Group
--------------------------------
wtWebGraphAnalogIn57641UdpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
port number must be unique within the device."
::= { wtWebGraphAnalogIn57641UDP 1 }
wtWebGraphAnalogIn57641UdpEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this bit to enable UDP support:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : UDP enable"
::= { wtWebGraphAnalogIn57641UDP 2 }
-- wtWebGraphAnalogIn57641Syslog Group
--------------------------------
wtWebGraphAnalogIn57641SyslogServerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
::= { wtWebGraphAnalogIn57641Syslog 1 }
wtWebGraphAnalogIn57641SyslogServerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Portnumber of the Syslog servers, default 514."
::= { wtWebGraphAnalogIn57641Syslog 2 }
wtWebGraphAnalogIn57641SyslogSystemMessagesEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2: Diag Messages
Bit 3-7: unused"
::= { wtWebGraphAnalogIn57641Syslog 3 }
wtWebGraphAnalogIn57641SyslogEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set bit 0to enable Syslog:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Syslog enable"
::= { wtWebGraphAnalogIn57641Syslog 4 }
-- wtWebGraphAnalogIn57641FTP Group
--------------------------------
wtWebGraphAnalogIn57641FTPServerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the FTP server, which accepts the FTP messages."
::= { wtWebGraphAnalogIn57641FTP 1 }
wtWebGraphAnalogIn57641FTPServerControlPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Portnumber of the control port of the FTP server, default 21."
::= { wtWebGraphAnalogIn57641FTP 2 }
wtWebGraphAnalogIn57641FTPUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: user name."
::= { wtWebGraphAnalogIn57641FTP 3 }
wtWebGraphAnalogIn57641FTPPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: user password."
::= { wtWebGraphAnalogIn57641FTP 4 }
wtWebGraphAnalogIn57641FTPAccount OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: name of account."
::= { wtWebGraphAnalogIn57641FTP 5 }
wtWebGraphAnalogIn57641FTPOption OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit 0 switches the FTP Server in Passiv-Mode,
the Client controls the data connection on its own:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : PASV enable"
::= { wtWebGraphAnalogIn57641FTP 6 }
wtWebGraphAnalogIn57641FTPEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Bit 0 to enable FTP:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : FTP enable"
::= { wtWebGraphAnalogIn57641FTP 7 }
-- wtWebGraphAnalogIn57641Datalogger Group
--------------------------------
wtWebGraphAnalogIn57641LoggerTimebase OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641Datalogger-1Min(1),
wtWebGraphAnalogIn57641Datalogger-5Min(2),
wtWebGraphAnalogIn57641Datalogger-15Min(3),
wtWebGraphAnalogIn57641Datalogger-60Min(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time base of the data logger"
::= { wtWebGraphAnalogIn57641Datalogger 1 }
wtWebGraphAnalogIn57641LoggerSensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57641Datalogger 2 }
wtWebGraphAnalogIn57641DisplaySensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded sensor selection:
only selected sensors will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57641Datalogger 3 }
-- Graph Sensor Color Table
wtWebGraphAnalogIn57641SensorColorTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57641SensorColorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensor colors for the praphical presentation."
::= { wtWebGraphAnalogIn57641Datalogger 4 }
wtWebGraphAnalogIn57641SensorColorEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57641SensorColorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Index numbers of the sensors."
INDEX { wtWebGraphAnalogIn57641SensorNo }
::= { wtWebGraphAnalogIn57641SensorColorTable 1 }
WtWebGraphAnalogIn57641SensorColorEntry ::= SEQUENCE {
wtWebGraphAnalogIn57641SensorColor OCTET STRING
}
wtWebGraphAnalogIn57641SensorColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Color of the sensors at the praphical presention."
::= { wtWebGraphAnalogIn57641SensorColorEntry 1 }
wtWebGraphAnalogIn57641AutoScaleEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If bit 0 is set, vertical auto scale is enabled:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Auto Scale enable"
::= { wtWebGraphAnalogIn57641Datalogger 5 }
wtWebGraphAnalogIn57641VerticalUpperLimit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value defines the maximum temperature shown in the graphical presentation,
if no auto scaling is selected.
Temperature in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641Datalogger 6 }
wtWebGraphAnalogIn57641VerticalLowerLimit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value defines the minimum temperature shown in the graphical presentation,
if no auto scaling is selected.
Temperature in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641Datalogger 7 }
wtWebGraphAnalogIn57641HorizontalZoom OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57641Zoom-25min(1),
wtWebGraphAnalogIn57641Zoom-75min(2),
wtWebGraphAnalogIn57641Zoom-5hrs(3),
wtWebGraphAnalogIn57641Zoom-30hrs(4),
wtWebGraphAnalogIn57641Zoom-5days(5),
wtWebGraphAnalogIn57641Zoom-25days(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the default zoom stage, if no auto scaling is selected."
::= { wtWebGraphAnalogIn57641Datalogger 8 }
-- wtWebGraphAnalogIn57641Alarm Group
----------------------------
wtWebGraphAnalogIn57641AlarmCount OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of independent alarms."
::= { wtWebGraphAnalogIn57641Alarm 1 }
-- Alarm Interface Table
wtWebGraphAnalogIn57641AlarmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57641AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of alarm indices."
::= { wtWebGraphAnalogIn57641Alarm 2 }
wtWebGraphAnalogIn57641AlarmIfEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57641AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the alarms."
INDEX { wtWebGraphAnalogIn57641AlarmNo }
::= { wtWebGraphAnalogIn57641AlarmIfTable 1 }
WtWebGraphAnalogIn57641AlarmIfEntry ::= SEQUENCE {
wtWebGraphAnalogIn57641AlarmNo INTEGER
}
wtWebGraphAnalogIn57641AlarmNo OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm number."
::= { wtWebGraphAnalogIn57641AlarmIfEntry 1 }
-- Alarm Table
wtWebGraphAnalogIn57641AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57641AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the alarm number."
::= { wtWebGraphAnalogIn57641Alarm 3 }
wtWebGraphAnalogIn57641AlarmEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57641AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm parameters of the individual alarms."
INDEX { wtWebGraphAnalogIn57641AlarmNo }
::= { wtWebGraphAnalogIn57641AlarmTable 1 }
WtWebGraphAnalogIn57641AlarmEntry ::= SEQUENCE {
wtWebGraphAnalogIn57641AlarmTrigger OCTET STRING,
wtWebGraphAnalogIn57641AlarmMin OCTET STRING,
wtWebGraphAnalogIn57641AlarmMax OCTET STRING,
wtWebGraphAnalogIn57641AlarmHysteresis OCTET STRING,
wtWebGraphAnalogIn57641AlarmDelay OCTET STRING,
wtWebGraphAnalogIn57641AlarmInterval OCTET STRING,
wtWebGraphAnalogIn57641AlarmEnable OCTET STRING,
wtWebGraphAnalogIn57641AlarmEMailAddr OCTET STRING,
wtWebGraphAnalogIn57641AlarmMailSubject OCTET STRING,
wtWebGraphAnalogIn57641AlarmMailText OCTET STRING,
wtWebGraphAnalogIn57641AlarmManagerIP OCTET STRING,
wtWebGraphAnalogIn57641AlarmTrapText OCTET STRING,
wtWebGraphAnalogIn57641AlarmMailOptions OCTET STRING,
wtWebGraphAnalogIn57641AlarmTcpIpAddr OCTET STRING,
wtWebGraphAnalogIn57641AlarmTcpPort INTEGER,
wtWebGraphAnalogIn57641AlarmTcpText OCTET STRING,
wtWebGraphAnalogIn57641AlarmClearMailSubject OCTET STRING,
wtWebGraphAnalogIn57641AlarmClearMailText OCTET STRING,
wtWebGraphAnalogIn57641AlarmClearTrapText OCTET STRING,
wtWebGraphAnalogIn57641AlarmClearTcpText OCTET STRING,
wtWebGraphAnalogIn57641Alarm2Min OCTET STRING,
wtWebGraphAnalogIn57641Alarm2Max OCTET STRING,
wtWebGraphAnalogIn57641Alarm2Hysteresis OCTET STRING,
wtWebGraphAnalogIn57641AlarmSyslogIpAddr OCTET STRING,
wtWebGraphAnalogIn57641AlarmSyslogPort INTEGER,
wtWebGraphAnalogIn57641AlarmSyslogText OCTET STRING,
wtWebGraphAnalogIn57641AlarmSyslogClearText OCTET STRING,
wtWebGraphAnalogIn57641AlarmFtpDataPort OCTET STRING,
wtWebGraphAnalogIn57641AlarmFtpFileName OCTET STRING,
wtWebGraphAnalogIn57641AlarmFtpText OCTET STRING,
wtWebGraphAnalogIn57641AlarmFtpClearText OCTET STRING,
wtWebGraphAnalogIn57641AlarmFtpOption OCTET STRING,
wtWebGraphAnalogIn57641AlarmTimerCron OCTET STRING
}
wtWebGraphAnalogIn57641AlarmTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57641AlarmEntry 1 }
wtWebGraphAnalogIn57641AlarmMin OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum temperature in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641AlarmEntry 2 }
wtWebGraphAnalogIn57641AlarmMax OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum temperature in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641AlarmEntry 3 }
wtWebGraphAnalogIn57641AlarmHysteresis OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641AlarmEntry 4 }
wtWebGraphAnalogIn57641AlarmDelay OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes)."
::= { wtWebGraphAnalogIn57641AlarmEntry 5 }
wtWebGraphAnalogIn57641AlarmInterval OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send interval for alarm messages."
::= { wtWebGraphAnalogIn57641AlarmEntry 6 }
wtWebGraphAnalogIn57641AlarmEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable"
::= { wtWebGraphAnalogIn57641AlarmEntry 7 }
wtWebGraphAnalogIn57641AlarmEMailAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E-Mail address for sending the alarm mail to."
::= { wtWebGraphAnalogIn57641AlarmEntry 8 }
wtWebGraphAnalogIn57641AlarmMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm mail."
::= { wtWebGraphAnalogIn57641AlarmEntry 9 }
wtWebGraphAnalogIn57641AlarmMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time."
::= { wtWebGraphAnalogIn57641AlarmEntry 10 }
wtWebGraphAnalogIn57641AlarmManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the SNMP Manager which accepts the trap."
::= { wtWebGraphAnalogIn57641AlarmEntry 11 }
wtWebGraphAnalogIn57641AlarmTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebGraphAnalogIn57641AlarmEntry 12 }
wtWebGraphAnalogIn57641AlarmMailOptions OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57641AlarmEntry 13 }
wtWebGraphAnalogIn57641AlarmTcpIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the trap."
::= { wtWebGraphAnalogIn57641AlarmEntry 14 }
wtWebGraphAnalogIn57641AlarmTcpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the TCP server which accepts the trap."
::= { wtWebGraphAnalogIn57641AlarmEntry 15 }
wtWebGraphAnalogIn57641AlarmTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebGraphAnalogIn57641AlarmEntry 16 }
wtWebGraphAnalogIn57641AlarmClearMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm clear mail."
::= { wtWebGraphAnalogIn57641AlarmEntry 17 }
wtWebGraphAnalogIn57641AlarmClearMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time."
::= { wtWebGraphAnalogIn57641AlarmEntry 18 }
wtWebGraphAnalogIn57641AlarmClearTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebGraphAnalogIn57641AlarmEntry 19 }
wtWebGraphAnalogIn57641AlarmClearTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebGraphAnalogIn57641AlarmEntry 20 }
wtWebGraphAnalogIn57641Alarm2Min OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum rel. Humidity in percent with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641AlarmEntry 21 }
wtWebGraphAnalogIn57641Alarm2Max OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum rel.Humidity in percent with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641AlarmEntry 22 }
wtWebGraphAnalogIn57641Alarm2Hysteresis OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hysterese rel. Humidity in percent with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641AlarmEntry 23 }
wtWebGraphAnalogIn57641AlarmSyslogIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the syslog server to which the Webio device should send syslog messages."
::= { wtWebGraphAnalogIn57641AlarmEntry 24 }
wtWebGraphAnalogIn57641AlarmSyslogPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the syslog server to which the Webio device should send syslog messages."
::= { wtWebGraphAnalogIn57641AlarmEntry 25 }
wtWebGraphAnalogIn57641AlarmSyslogText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body."
::= { wtWebGraphAnalogIn57641AlarmEntry 26 }
wtWebGraphAnalogIn57641AlarmSyslogClearText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message."
::= { wtWebGraphAnalogIn57641AlarmEntry 27 }
wtWebGraphAnalogIn57641AlarmFtpDataPort OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
::= { wtWebGraphAnalogIn57641AlarmEntry 28 }
wtWebGraphAnalogIn57641AlarmFtpFileName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the file including path informations."
::= { wtWebGraphAnalogIn57641AlarmEntry 29 }
wtWebGraphAnalogIn57641AlarmFtpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Message text to store on the FTP server."
::= { wtWebGraphAnalogIn57641AlarmEntry 30 }
wtWebGraphAnalogIn57641AlarmFtpClearText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear message to store on the FTP server."
::= { wtWebGraphAnalogIn57641AlarmEntry 31 }
wtWebGraphAnalogIn57641AlarmFtpOption OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STORE
Bit 1 : APPEND
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57641AlarmEntry 32 }
wtWebGraphAnalogIn57641AlarmTimerCron OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Range 0-59
2. Hours Range 0-23, 0 is midnight
3: Day of month Range 1-31
4: Month Range 1-12
5: Weekday Range 0-6, 0 is sunday
Syntax for every field:
- an asterix (*) enables every possible setting of a field
- single numbers seperated by commas
- a partition within the allowed range (1-5)
- step size within an partition of the allowed range (0-59/2: every second minute)."
::= { wtWebGraphAnalogIn57641AlarmEntry 33 }
-- wtWebGraphAnalogIn57641GraphicsBase Group
----------------------------
wtWebGraphAnalogIn57641GraphicsBaseEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the viewing options of the graphic:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Auto scroll enable
Bit 1 : Show table
Bit 2 : Show graph
Bit 3 : Show control buttons
Bit 4 : Show config menu
Bit 5-7: unused"
::= { wtWebGraphAnalogIn57641GraphicsBase 1 }
wtWebGraphAnalogIn57641GraphicsBaseWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the width of the graphic in pixels."
::= { wtWebGraphAnalogIn57641GraphicsBase 2 }
wtWebGraphAnalogIn57641GraphicsBaseHeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the height of the graphic in pixels."
::= { wtWebGraphAnalogIn57641GraphicsBase 3 }
wtWebGraphAnalogIn57641GraphicsBaseFrameColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame color definition in RGB."
::= { wtWebGraphAnalogIn57641GraphicsBase 4 }
wtWebGraphAnalogIn57641GraphicsBaseBackgroundColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Background color definition in RGB."
::= { wtWebGraphAnalogIn57641GraphicsBase 5 }
wtWebGraphAnalogIn57641GraphicsBasePollingrate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the pollingrate in seconds,
which defines the refreshing intervall of the graphic."
::= { wtWebGraphAnalogIn57641GraphicsBase 6 }
-- wtWebGraphAnalogIn57641GraphicsSelect Group
----------------------------
wtWebGraphAnalogIn57641GraphicsSelectDisplaySensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded sensor selection:
only selected sensors will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
Bit 4: Sensor 5
Bit 5: Sensor 6
Bit 6: Sensor 7
Bit 7: Sensor 8"
::= { wtWebGraphAnalogIn57641GraphicsSelect 1 }
wtWebGraphAnalogIn57641GraphicsSelectDisplayShowExtrem OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded sensor selection:
only selected sensors will be shown with minima and maxima:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
Bit 4: Sensor 5
Bit 5: Sensor 6
Bit 6: Sensor 7
Bit 7: Sensor 8"
::= { wtWebGraphAnalogIn57641GraphicsSelect 2 }
-- Graph Sensor Color Table
wtWebGraphAnalogIn57641SensorColor2Table OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57641SensorColor2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensor colors for the praphical presentation."
::= { wtWebGraphAnalogIn57641GraphicsSelect 3 }
wtWebGraphAnalogIn57641SensorColor2Entry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57641SensorColor2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the sensors."
INDEX { wtWebGraphAnalogIn57641SensorNo }
::= { wtWebGraphAnalogIn57641SensorColor2Table 1 }
WtWebGraphAnalogIn57641SensorColor2Entry ::= SEQUENCE {
wtWebGraphAnalogIn57641GraphicsSensorColor OCTET STRING,
wtWebGraphAnalogIn57641GraphicsSelectScale OCTET STRING
}
wtWebGraphAnalogIn57641GraphicsSensorColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Color of the sensors at the praphical presention."
::= { wtWebGraphAnalogIn57641SensorColor2Entry 1 }
wtWebGraphAnalogIn57641GraphicsSelectScale OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Assignes one of 4 scales to a sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Use Scale 1
Bit 1 : Use Scale 2
Bit 2 : Use Scale 3
Bit 3 : Use Scale 4
Bit 4-7: unused"
::= { wtWebGraphAnalogIn57641SensorColor2Entry 2 }
-- wtWebGraphAnalogIn57641GraphicsScale Group
----------------------------
wtWebGraphAnalogIn57641GraphicsScaleAutoScaleEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the Auto Scale Mode:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto scale enable
Bit 1 : Scale 2 Auto scale enable
Bit 2 : Scale 3 Auto scale enable
Bit 3 : Scale 4 Auto scale enable
Bit 4-7: unused"
::= { wtWebGraphAnalogIn57641GraphicsScale 1 }
wtWebGraphAnalogIn57641GraphicsScaleAutoFitEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the Auto Fit Mode::
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto fit enable
Bit 1 : Scale 2 Auto fit enable
Bit 2 : Scale 3 Auto fit enable
Bit 3 : Scale 4 Auto fit enable
Bit 4-7: unused"
::= { wtWebGraphAnalogIn57641GraphicsScale 2 }
wtWebGraphAnalogIn57641GraphicsScale1Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Minimum."
::= { wtWebGraphAnalogIn57641GraphicsScale 3 }
wtWebGraphAnalogIn57641GraphicsScale2Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Minimum."
::= { wtWebGraphAnalogIn57641GraphicsScale 4 }
wtWebGraphAnalogIn57641GraphicsScale3Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 3: Minimum."
::= { wtWebGraphAnalogIn57641GraphicsScale 5 }
wtWebGraphAnalogIn57641GraphicsScale4Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 4: Minimum."
::= { wtWebGraphAnalogIn57641GraphicsScale 6 }
wtWebGraphAnalogIn57641GraphicsScale1Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Maximum."
::= { wtWebGraphAnalogIn57641GraphicsScale 7 }
wtWebGraphAnalogIn57641GraphicsScale2Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Maximum."
::= { wtWebGraphAnalogIn57641GraphicsScale 8 }
wtWebGraphAnalogIn57641GraphicsScale3Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 3: Maximum."
::= { wtWebGraphAnalogIn57641GraphicsScale 9 }
wtWebGraphAnalogIn57641GraphicsScale4Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 4: Maximum."
::= { wtWebGraphAnalogIn57641GraphicsScale 10 }
wtWebGraphAnalogIn57641GraphicsScale1Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Unit."
::= { wtWebGraphAnalogIn57641GraphicsScale 11 }
wtWebGraphAnalogIn57641GraphicsScale2Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Unit."
::= { wtWebGraphAnalogIn57641GraphicsScale 12 }
wtWebGraphAnalogIn57641GraphicsScale3Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 3: Unit."
::= { wtWebGraphAnalogIn57641GraphicsScale 13 }
wtWebGraphAnalogIn57641GraphicsScale4Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 4: Unit."
::= { wtWebGraphAnalogIn57641GraphicsScale 14 }
-- wtWebGraphAnalogIn57641Ports Group
----------------------------
-- Table
wtWebGraphAnalogIn57641PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57641PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the sensor number."
::= { wtWebGraphAnalogIn57641Ports 1 }
wtWebGraphAnalogIn57641PortEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57641PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Sensor parameters for the individual sensors."
INDEX { wtWebGraphAnalogIn57641SensorNo }
::= { wtWebGraphAnalogIn57641PortTable 1 }
WtWebGraphAnalogIn57641PortEntry ::= SEQUENCE {
wtWebGraphAnalogIn57641PortName OCTET STRING,
wtWebGraphAnalogIn57641PortText OCTET STRING,
wtWebGraphAnalogIn57641PortOffset1 OCTET STRING,
wtWebGraphAnalogIn57641SetPoint1 OCTET STRING,
wtWebGraphAnalogIn57641PortOffset2 OCTET STRING,
wtWebGraphAnalogIn57641SetPoint2 OCTET STRING,
wtWebGraphAnalogIn57641PortComment OCTET STRING,
wtWebGraphAnalogIn57641PortSensorSelect OCTET STRING,
wtWebGraphAnalogIn57641PortUnit OCTET STRING,
wtWebGraphAnalogIn57641PortScale0 OCTET STRING,
wtWebGraphAnalogIn57641PortScale100 OCTET STRING
}
wtWebGraphAnalogIn57641PortName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the sensor."
::= { wtWebGraphAnalogIn57641PortEntry 1 }
wtWebGraphAnalogIn57641PortText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the sensor."
::= { wtWebGraphAnalogIn57641PortEntry 2 }
wtWebGraphAnalogIn57641PortOffset1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at set point 1."
::= { wtWebGraphAnalogIn57641PortEntry 3 }
wtWebGraphAnalogIn57641SetPoint1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: set point 1 in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641PortEntry 4 }
wtWebGraphAnalogIn57641PortOffset2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at set point 2."
::= { wtWebGraphAnalogIn57641PortEntry 5 }
wtWebGraphAnalogIn57641SetPoint2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: set point 2 in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57641PortEntry 6 }
wtWebGraphAnalogIn57641PortComment OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: informations of date, name of operator, reference devices."
::= { wtWebGraphAnalogIn57641PortEntry 7 }
wtWebGraphAnalogIn57641PortSensorSelect OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options for sensor 1:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : 0-20mA (default)
Bit 1 : 4-20mA
Bit 2 : Disconnect
Bit 3-7: unused
Binary coded options for sensor 2:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : 0-10V (default)
Bit 1 : Disconnect
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57641PortEntry 8 }
wtWebGraphAnalogIn57641PortUnit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed unit."
::= { wtWebGraphAnalogIn57641PortEntry 9 }
wtWebGraphAnalogIn57641PortScale0 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed value in 1/1000 at 0% full scale range.
Range: -999999.999 to 999999.999"
::= { wtWebGraphAnalogIn57641PortEntry 10 }
wtWebGraphAnalogIn57641PortScale100 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed value in 1/1000 at 100% full scale range.
Range: -999999.999 to 999999.999"
::= { wtWebGraphAnalogIn57641PortEntry 11 }
-- wtWebGraphAnalogIn57641Manufact Group
----------------------------
wtWebGraphAnalogIn57641MfName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer company name"
::= { wtWebGraphAnalogIn57641Manufact 1 }
wtWebGraphAnalogIn57641MfAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer address."
::= { wtWebGraphAnalogIn57641Manufact 2 }
wtWebGraphAnalogIn57641MfHotline OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer hotline."
::= { wtWebGraphAnalogIn57641Manufact 3 }
wtWebGraphAnalogIn57641MfInternet OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer Internet address."
::= { wtWebGraphAnalogIn57641Manufact 4 }
wtWebGraphAnalogIn57641MfDeviceTyp OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer device name (model number)."
::= { wtWebGraphAnalogIn57641Manufact 5 }
wtWebGraphAnalogIn57641MfOrderNo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer part number."
::= { wtWebGraphAnalogIn57641Manufact 6 }
-- wtWebGraphAnalogIn57641Diag Group
----------------------------
wtWebGraphAnalogIn57641DiagErrorCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of entries in the error memory."
::= { wtWebGraphAnalogIn57641Diag 1 }
wtWebGraphAnalogIn57641DiagBinaryError OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error causes coded bit-by-bit."
::= { wtWebGraphAnalogIn57641Diag 2 }
wtWebGraphAnalogIn57641DiagErrorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this variable is used as an index to read
an error massege from wtWebGraphAnalogIn57641DiagErrorMessage.
Errors are numbered from 1 to wtWebGraphAnalogIn57641DiagErrorCount.
Writing a valid value into this variable, making the appropriate
message readable from wtWebGraphAnalogIn57641DiagErrorMessage."
::= { wtWebGraphAnalogIn57641Diag 3 }
wtWebGraphAnalogIn57641DiagErrorMessage OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Using wtWebGraphAnalogIn57641DiagErrorIndex as an index, the appropriate message is available."
::= { wtWebGraphAnalogIn57641Diag 4 }
wtWebGraphAnalogIn57641DiagErrorClear OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Writing 1 into this variable clears all diagnosis messages."
::= { wtWebGraphAnalogIn57641Diag 5 }
-- TRAP DEFINITIONS
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
wtWebGraphAnalogIn57641Alert1 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 31
wtWebGraphAnalogIn57641Alert2 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 32
wtWebGraphAnalogIn57641Alert3 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 33
wtWebGraphAnalogIn57641Alert4 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 34
wtWebGraphAnalogIn57641Alert5 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 35
wtWebGraphAnalogIn57641Alert6 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 36
wtWebGraphAnalogIn57641Alert7 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 37
wtWebGraphAnalogIn57641Alert8 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 38
wtWebGraphAnalogIn57641Alert9 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 1"
--#SUMMARY "Release Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 91
wtWebGraphAnalogIn57641Alert10 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 2"
--#SUMMARY "Release Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 92
wtWebGraphAnalogIn57641Alert11 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 3"
--#SUMMARY "Release Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 93
wtWebGraphAnalogIn57641Alert12 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 4"
--#SUMMARY "Release Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 94
wtWebGraphAnalogIn57641Alert13 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 5"
--#SUMMARY "Release Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 95
wtWebGraphAnalogIn57641Alert14 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 6"
--#SUMMARY "Release Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 96
wtWebGraphAnalogIn57641Alert15 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 7"
--#SUMMARY "Release Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 97
wtWebGraphAnalogIn57641Alert16 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES { wtWebGraphAnalogIn57641AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 8"
--#SUMMARY "Release Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 98
wtWebGraphAnalogIn57641AlertDiag TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57641
VARIABLES {
wtWebGraphAnalogIn57641DiagErrorIndex,
wtWebGraphAnalogIn57641DiagErrorMessage
}
DESCRIPTION
"This SNMP trap is generated when a diagnosis/error message was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Diagnose Error"
--#SUMMARY "Diagnose error index: %d, Message: %s."
--#ARGUMENTS {0,1}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
::= 110
END