Observium_CE/mibs/webgraph/WebGraph-AnalogIO-57762-US-MIB

3318 lines
110 KiB
Plaintext

WebGraph-AnalogIO-57762-US-MIB DEFINITIONS ::= BEGIN
----------------------------------------------------------------
-- Revison: 1.31
----------------------------------------------------------------
-- 27.03.2018 New: Mail Auth, SNMP destination port
-- Binary HttpPort, time base report
-- MQTT, REST
----------------------------------------------------------------
-- Revison: 1.30
----------------------------------------------------------------
-- 08.01.2010 New: Reports
--
----------------------------------------------------------------
-- Revison: 1.29
----------------------------------------------------------------
-- 01.10.2009 Webio
-- New Analog Out: 57762
----------------------------------------------------------------
-- Revison: 1.28
----------------------------------------------------------------
-- 02.12.2008 Webio
-- New Graphics java script base parameter
----------------------------------------------------------------
-- Revison: 1.27
----------------------------------------------------------------
-- 09.11.2006 Webio
-- DHCP enable
----------------------------------------------------------------
-- Revison: 1.26
----------------------------------------------------------------
-- 28.06.2006 New: Community String Trap
--
----------------------------------------------------------------
-- Revison: 1.25
----------------------------------------------------------------
-- 25.11.2005 #57641, WebGraph AnalogIn
-- OID correction
----------------------------------------------------------------
-- Revison: 1.24
----------------------------------------------------------------
-- 26.07.2005 #57641, WebGraph AnalogIn
-- CRON timer function
----------------------------------------------------------------
-- Revison: 1.23
----------------------------------------------------------------
-- 14.07.2005 #57641, WebGraph AnalogIn
-- FTP functions
----------------------------------------------------------------
-- Revison: 1.22
----------------------------------------------------------------
-- 17.05.2005 #57641, WebGraph AnalogIn
-- Trap NMS annotations
----------------------------------------------------------------
-- Revison: 1.21
----------------------------------------------------------------
-- 19.04.2005 #57605, WebGraph Themometer
-- Mail Authentication
----------------------------------------------------------------
-- Revison: 1.20
----------------------------------------------------------------
-- 05.11.2004 #57606, WebGraph Thermo-Hygrometer
-- New: Syslog
--
----------------------------------------------------------------
-- Revison: 1.19
----------------------------------------------------------------
-- 08.09.2004 #57606 WebGraph Thermo-Hygrometer
-- New:
-- wtWebGraphThermHygroAlarmRHMin
-- wtWebGraphThermHygroAlarmRHMax
-- wtWebGraphThermHygroAlarmRHHysteresis
-- wtWebGraphThermHygroPortSensorSelect
-- wtWebGraphThermHygroAlarmDeltaTemp
-- wtWebGraphThermHygroAlarmAHMin
-- wtWebGraphThermHygroAlarmAHMax
----------------------------------------------------------------
-- Revison: 1.18
----------------------------------------------------------------
-- 21.07.2004 #57601/3/4, Webio Anx
-- New:
-- Diagnosis
----------------------------------------------------------------
-- Revison: 1.17
----------------------------------------------------------------
-- 28.06.2004 #57630/1/2, Webio Digital
-- Neu: Puls Mode
----------------------------------------------------------------
-- Revison: 1.16
----------------------------------------------------------------
-- 16.04.2004 New: #57632, Webio Digital EA24x24
--
-- #57630/1, Webio Digital EA12x12
-- New:
-- wtWebioEA12x12InputCounterClear
----------------------------------------------------------------
-- Revison: 1.15
----------------------------------------------------------------
-- 27.02.2004 #57630/1, Webio Digital EA12x12
-- New:
-- Length changed to 32 Bit:
-- wtWebioEA12x12InputValue
-- wtWebioEA12x12OutputValue
-- wtWebioEA12x12LoadControlView
-- wtWebioEA12x12LCShutDownView
-- wtWebioEA12x12SetOutput
-- wtWebioEA12x12AlarmInputTrigger
-- wtWebioEA12x12AlarmOutputTrigger
-- wtWebioEA12x12PortOutputSafetyState
----------------------------------------------------------------
-- Revison: 1.14
----------------------------------------------------------------
-- 16.02.2004 #57630/1, Webio Digital EA12x12
-- New:
-- Text: Location, Contact
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
-- Alarm: ColdStart / WarmStart trigger
--
-- #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New:
-- Alarm Hysteresis
-- Alarm Clear Traps and Mails
----------------------------------------------------------------
-- Revison: 1.13
----------------------------------------------------------------
-- 05.02.2004 #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New:
-- Text: Location, Contact
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
-- Alarm: ColdStart / WarmStart trigger
----------------------------------------------------------------
-- Revison: 1.12
----------------------------------------------------------------
-- 05.11.2003 #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New features:
-- Mail : Option CSV attachment
-- Port : Offset calibration
-- Alarm : TCP Client mode
----------------------------------------------------------------
-- Revison: 1.11
----------------------------------------------------------------
-- 28.10.2003 #57630/1, Webio Digital EA12x12
-- New features:
-- Alarm : TCP Client mode
-- Inputs: Puls filter
----------------------------------------------------------------
-- Revison: 1.10
----------------------------------------------------------------
-- 22.07.2003 #57630, Webio Digital EA12x12
-- New navigation tree, new binary modes
--
----------------------------------------------------------------
-- Revison: 1.09
----------------------------------------------------------------
-- 24.03.2003 Trap Enterprise (Type 1, 2) corrected
----------------------------------------------------------------
-- Revison: 1.08
----------------------------------------------------------------
-- 04.03.2003 reconciled the language versions DE/US
----------------------------------------------------------------
-- Revison: 1.07
----------------------------------------------------------------
-- 25.02.2003 Correction: wtWebioEA12x12LoadControl
----------------------------------------------------------------
-- Revison: 1.06
----------------------------------------------------------------
-- 24.02.2003 New:
-- #57630, Webio EA12x12, LoadControl Group
-- Correction: Trap variable names
----------------------------------------------------------------
-- Revison: 1.05
----------------------------------------------------------------
-- 21.01.2003 New:
-- #57630, Webio EA12x12
----------------------------------------------------------------
-- Revison: 1.04
----------------------------------------------------------------
-- 02.01.2003 New:
-- #57601, 1xWebThermometer
-- #57603, 2xWebThermometer, 8 alarms
----------------------------------------------------------------
-- Revison: 1.03
----------------------------------------------------------------
-- 21.11.2002 New:
-- #57604, 2xWebThermometer, BOOTP, StartupSite
-- #57603, 8xWebThermometer, BOOTP, StartupSite
----------------------------------------------------------------
-- Revison: 1.02
----------------------------------------------------------------
-- 26.07.2002 New:
-- #57604, 2xWebThermometer
-- #57603, 8xWebThermometer
--
IMPORTS
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
DisplayString, PhysAddress FROM RFC1213-MIB
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
-- IpAddress ::=
-- [APPLICATION 0]
-- IMPLICIT OCTET STRING (SIZE (4))
-- Counter ::=
-- [APPLICATION 1]
-- IMPLICIT INTEGER (0..4294967295)
-- Gauge ::=
-- [APPLICATION 2]
-- IMPLICIT INTEGER (0..4294967295)
-- TimeTicks ::=
-- [APPLICATION 3]
-- IMPLICIT INTEGER (0..4294967295)
-- DisplayString ::= OCTET STRING
-- PhysAddress ::= OCTET STRING
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
-- privat OBJECT IDENTIFIER ::= { internet 4 }
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
-- Wiesemann & Theis Com-Server MIB
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
-- wtWebGraph Tree
wtWebGraphAnalog57762 OBJECT IDENTIFIER ::= { wtWebio 29 }
-- wtWebGraphAnalog57762 Tree
wtWebGraphAnalog57762Inventory OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 1 }
wtWebGraphAnalog57762SessCntrl OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 2 }
wtWebGraphAnalog57762Config OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 3 }
wtWebGraphAnalog57762Diag OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 4 }
-- wtWebGraphAnalog57762Config Tree
wtWebGraphAnalog57762Device OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 1 }
wtWebGraphAnalog57762Ports OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 2 }
wtWebGraphAnalog57762Manufact OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 3 }
-- wtWebGraphAnalog57762Device Tree
wtWebGraphAnalog57762Text OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 1 }
wtWebGraphAnalog57762TimeDate OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 2 }
wtWebGraphAnalog57762Basic OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 3 }
wtWebGraphAnalog57762Datalogger OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 4 }
wtWebGraphAnalog57762Alarm OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 5 }
wtWebGraphAnalog57762Graphics OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 6 }
-- wtWebGraphAnalog57762TimeDate Tree
wtWebGraphAnalog57762TimeZone OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 1 }
wtWebGraphAnalog57762TimeServer OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 2 }
wtWebGraphAnalog57762DeviceClock OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 3 }
-- wtWebGraphAnalog57762Basic Tree
wtWebGraphAnalog57762Network OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 1 }
wtWebGraphAnalog57762HTTP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 2 }
wtWebGraphAnalog57762Mail OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 3 }
wtWebGraphAnalog57762SNMP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 4 }
wtWebGraphAnalog57762UDP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 5 }
wtWebGraphAnalog57762Syslog OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 6 }
wtWebGraphAnalog57762FTP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 7 }
wtWebGraphAnalog57762Language OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 8 }
wtWebGraphAnalog57762Binary OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 9 }
wtWebGraphAnalog57762MQTT OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 12 }
wtWebGraphAnalog57762REST OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 13 }
-- wtWebGraphAnalog57762Graphics Tree
wtWebGraphAnalog57762GraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 1 }
wtWebGraphAnalog57762GraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 2 }
wtWebGraphAnalog57762GraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 3 }
-- wtWebGraphAnalog57762Inventory Group
------------------------
wtWebGraphAnalog57762Sensors OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of sensors"
::= { wtWebGraphAnalog57762Inventory 1 }
-- Interface Table
wtWebGraphAnalog57762SensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensors."
::= { wtWebGraphAnalog57762Inventory 2 }
wtWebGraphAnalog57762SensorEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensor numbers."
INDEX { wtWebGraphAnalog57762SensorNo }
::= { wtWebGraphAnalog57762SensorTable 1 }
WtWebGraphAnalog57762SensorEntry ::= SEQUENCE {
wtWebGraphAnalog57762SensorNo INTEGER
}
wtWebGraphAnalog57762SensorNo OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sensor number."
::= { wtWebGraphAnalog57762SensorEntry 1 }
-- wtWebGraphAnalog57762Values Table
wtWebGraphAnalog57762ValuesTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762ValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of measurement values corresponding to the channel numbers."
::= { wtWebGraphAnalog57762Inventory 3 }
wtWebGraphAnalog57762ValuesEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762ValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Measurement values of the sensors."
INDEX { wtWebGraphAnalog57762SensorNo }
::= { wtWebGraphAnalog57762ValuesTable 1 }
WtWebGraphAnalog57762ValuesEntry ::= SEQUENCE{
wtWebGraphAnalog57762Values OCTET STRING
}
wtWebGraphAnalog57762Values OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Measurement value of the sensor, ASCII.
This value will be translated according to the ports settings
for the read and write operations."
::= { wtWebGraphAnalog57762ValuesEntry 1 }
-- wtWebGraphAnalog57762BinaryValues Table
wtWebGraphAnalog57762BinaryValuesTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of binary measurement values corresponding to the channel numbers."
::= { wtWebGraphAnalog57762Inventory 4 }
wtWebGraphAnalog57762BinaryValuesEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762BinaryValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Binary measurement values of the sensors."
INDEX { wtWebGraphAnalog57762SensorNo }
::= { wtWebGraphAnalog57762BinaryValuesTable 1 }
WtWebGraphAnalog57762BinaryValuesEntry ::= SEQUENCE{
wtWebGraphAnalog57762BinaryValues INTEGER
}
wtWebGraphAnalog57762BinaryValues OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary measurement value of the sensor in 1/1000,
signed number, 0x7FFFFFFF indicates an invalid value.
This value will be translated according to the ports settings
for the read and write operations."
::= { wtWebGraphAnalog57762BinaryValuesEntry 1 }
-- wtWebGraphAnalog57762ValuesPoint Table
wtWebGraphAnalog57762ValuesPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762ValuesPointEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of measurement values corresponding to the channel numbers."
::= { wtWebGraphAnalog57762Inventory 8 }
wtWebGraphAnalog57762ValuesPointEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762ValuesPointEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Measurement values of the sensors."
INDEX { wtWebGraphAnalog57762SensorNo }
::= { wtWebGraphAnalog57762ValuesPointTable 1 }
WtWebGraphAnalog57762ValuesPointEntry ::= SEQUENCE{
wtWebGraphAnalog57762ValuesPoint OCTET STRING
}
wtWebGraphAnalog57762ValuesPoint OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Measurement value of the sensor, ASCII.
This value will be translated according to the ports settings
for the read and write operations."
::= { wtWebGraphAnalog57762ValuesPointEntry 1 }
-- wtWebGraphAnalog57762SessCntrl Group
--------------------------------
wtWebGraphAnalog57762SessCntrlPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Entering this password opens a session which is ended by writing a 1 to
wtWebGraphAnalog57762SessCntrlLogout. When read this variable provides a string of
length zero."
::= { wtWebGraphAnalog57762SessCntrl 1 }
wtWebGraphAnalog57762SessCntrlConfigMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762SessCntrl-NoSession(0),
wtWebGraphAnalog57762SessCntrl-Session(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When the device is in SNMP configuration mode, the value 1 is
returned, otherwise 0. If the read value is 0 even though the
password was written, the device is already in config mode and the
variables can only be read."
::= { wtWebGraphAnalog57762SessCntrl 2 }
wtWebGraphAnalog57762SessCntrlLogout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session
and all parameters are stored.
Writing a 2 discards all entries again.
When read this variable provides the value 0."
::= { wtWebGraphAnalog57762SessCntrl 3 }
wtWebGraphAnalog57762SessCntrlAdminPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public."
::= { wtWebGraphAnalog57762SessCntrl 4 }
wtWebGraphAnalog57762SessCntrlConfigPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid password is public. When read this variable provides a null-pointer."
::= { wtWebGraphAnalog57762SessCntrl 5 }
-- wtWebGraphAnalog57762Text Group
------------------------
wtWebGraphAnalog57762DeviceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the Webio, which is user definable."
::= { wtWebGraphAnalog57762Text 1 }
wtWebGraphAnalog57762DeviceText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the Webio, which is user definable."
::= { wtWebGraphAnalog57762Text 2 }
wtWebGraphAnalog57762DeviceLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the location of the Webio, which is user definable."
::= { wtWebGraphAnalog57762Text 3 }
wtWebGraphAnalog57762DeviceContact OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Contact address of the system operator of the Webio, which is user definable."
::= { wtWebGraphAnalog57762Text 4 }
-- wtWebGraphAnalog57762TimeZone Group
----------------------------
wtWebGraphAnalog57762TzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours for the time zone (winter time) with respect to UTC."
::= { wtWebGraphAnalog57762TimeZone 1 }
wtWebGraphAnalog57762TzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes for the time zone (winter time) with respect to UTC."
::= { wtWebGraphAnalog57762TimeZone 2 }
wtWebGraphAnalog57762TzEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Timezone"
::= { wtWebGraphAnalog57762TimeZone 3 }
wtWebGraphAnalog57762StTzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours of the time zone (summer time) with respect to UTC."
::= { wtWebGraphAnalog57762TimeZone 4 }
wtWebGraphAnalog57762StTzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes of the time zone (summer time) with respect to UTC."
::= { wtWebGraphAnalog57762TimeZone 5 }
wtWebGraphAnalog57762StTzEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Summertime"
::= { wtWebGraphAnalog57762TimeZone 6 }
wtWebGraphAnalog57762StTzStartMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762StartMonth-January(1),
wtWebGraphAnalog57762StartMonth-February(2),
wtWebGraphAnalog57762StartMonth-March(3),
wtWebGraphAnalog57762StartMonth-April(4),
wtWebGraphAnalog57762StartMonth-May(5),
wtWebGraphAnalog57762StartMonth-June(6),
wtWebGraphAnalog57762StartMonth-July(7),
wtWebGraphAnalog57762StartMonth-August(8),
wtWebGraphAnalog57762StartMonth-September(9),
wtWebGraphAnalog57762StartMonth-October(10),
wtWebGraphAnalog57762StartMonth-November(11),
wtWebGraphAnalog57762StartMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from winter time to summer time."
::= { wtWebGraphAnalog57762TimeZone 7 }
wtWebGraphAnalog57762StTzStartMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762StartMode-first(1),
wtWebGraphAnalog57762StartMode-second(2),
wtWebGraphAnalog57762StartMode-third(3),
wtWebGraphAnalog57762StartMode-fourth(4),
wtWebGraphAnalog57762StartMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the day of the week for which the change is made from winter time to summer time."
::= { wtWebGraphAnalog57762TimeZone 8 }
wtWebGraphAnalog57762StTzStartWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762StartWday-Sunday(1),
wtWebGraphAnalog57762StartWday-Monday(2),
wtWebGraphAnalog57762StartWday-Tuesday(3),
wtWebGraphAnalog57762StartWday-Thursday(4),
wtWebGraphAnalog57762StartWday-Wednesday(5),
wtWebGraphAnalog57762StartWday-Friday(6),
wtWebGraphAnalog57762StartWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from winter time to summer time"
::= { wtWebGraphAnalog57762TimeZone 9 }
wtWebGraphAnalog57762StTzStartHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebGraphAnalog57762TimeZone 10 }
wtWebGraphAnalog57762StTzStartMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebGraphAnalog57762TimeZone 11 }
wtWebGraphAnalog57762StTzStopMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762StopMonth-January(1),
wtWebGraphAnalog57762StopMonth-February(2),
wtWebGraphAnalog57762StopMonth-March(3),
wtWebGraphAnalog57762StopMonth-April(4),
wtWebGraphAnalog57762StopMonth-May(5),
wtWebGraphAnalog57762StopMonth-June(6),
wtWebGraphAnalog57762StopMonth-July(7),
wtWebGraphAnalog57762StopMonth-August(8),
wtWebGraphAnalog57762StopMonth-September(9),
wtWebGraphAnalog57762StopMonth-October(10),
wtWebGraphAnalog57762StopMonth-November(11),
wtWebGraphAnalog57762StopMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from summer time to winter time."
::= { wtWebGraphAnalog57762TimeZone 12 }
wtWebGraphAnalog57762StTzStopMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762StopMode-first(1),
wtWebGraphAnalog57762StopMode-second(2),
wtWebGraphAnalog57762StopMode-third(3),
wtWebGraphAnalog57762StopMode-fourth(4),
wtWebGraphAnalog57762StopMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the week day on which the change is made from summer time to winter time."
::= { wtWebGraphAnalog57762TimeZone 13 }
wtWebGraphAnalog57762StTzStopWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762StopWday-Sunday(1),
wtWebGraphAnalog57762StopWday-Monday(2),
wtWebGraphAnalog57762StopWday-Tuesday(3),
wtWebGraphAnalog57762StopWday-Thursday(4),
wtWebGraphAnalog57762StopWday-Wednesday(5),
wtWebGraphAnalog57762StopWday-Friday(6),
wtWebGraphAnalog57762StopWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from summer time to winter time."
::= { wtWebGraphAnalog57762TimeZone 14 }
wtWebGraphAnalog57762StTzStopHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebGraphAnalog57762TimeZone 15 }
wtWebGraphAnalog57762StTzStopMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebGraphAnalog57762TimeZone 16 }
-- wtWebGraphAnalog57762TimeServer Group
----------------------------
wtWebGraphAnalog57762TimeServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 1st time server in ASCII"
::= { wtWebGraphAnalog57762TimeServer 1 }
wtWebGraphAnalog57762TimeServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 2nd time server in ASCII"
::= { wtWebGraphAnalog57762TimeServer 2 }
wtWebGraphAnalog57762TsEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Time Server"
::= { wtWebGraphAnalog57762TimeServer 3 }
wtWebGraphAnalog57762TsSyncTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daily synchronisation time with the time server (hour: 0-23)."
::= { wtWebGraphAnalog57762TimeServer 4 }
-- wtWebGraphAnalog57762DeviceClock Group
----------------------------
wtWebGraphAnalog57762ClockHrs OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock hours taking into account the time zone settings."
::= { wtWebGraphAnalog57762DeviceClock 1 }
wtWebGraphAnalog57762ClockMin OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock minutes taking into account the time zone settings."
::= { wtWebGraphAnalog57762DeviceClock 2 }
wtWebGraphAnalog57762ClockDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Day of the month, taking into account the time zone settings."
::= { wtWebGraphAnalog57762DeviceClock 3 }
wtWebGraphAnalog57762ClockMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762ClockMonth-January(1),
wtWebGraphAnalog57762ClockMonth-February(2),
wtWebGraphAnalog57762ClockMonth-March(3),
wtWebGraphAnalog57762ClockMonth-April(4),
wtWebGraphAnalog57762ClockMonth-May(5),
wtWebGraphAnalog57762ClockMonth-June(6),
wtWebGraphAnalog57762ClockMonth-July(7),
wtWebGraphAnalog57762ClockMonth-August(8),
wtWebGraphAnalog57762ClockMonth-September(9),
wtWebGraphAnalog57762ClockMonth-October(10),
wtWebGraphAnalog57762ClockMonth-November(11),
wtWebGraphAnalog57762ClockMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Month, taking into account the time zone settings."
::= { wtWebGraphAnalog57762DeviceClock 4 }
wtWebGraphAnalog57762ClockYear OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Year, taking into account the time zone settings."
::= { wtWebGraphAnalog57762DeviceClock 5 }
-- wtWebGraphAnalog57762Network Group
------------------------
wtWebGraphAnalog57762IpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the Webio"
::= { wtWebGraphAnalog57762Network 1 }
wtWebGraphAnalog57762SubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subnet mask of the Webio"
::= { wtWebGraphAnalog57762Network 2 }
wtWebGraphAnalog57762Gateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway of the Webio"
::= { wtWebGraphAnalog57762Network 3 }
wtWebGraphAnalog57762DnsServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 1st DNS server in ASCII"
::= { wtWebGraphAnalog57762Network 4 }
wtWebGraphAnalog57762DnsServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 2nd DNS server in ASCII"
::= { wtWebGraphAnalog57762Network 5 }
wtWebGraphAnalog57762AddConfig OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Additional configuration (1=ON):
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: DHCP disable
Bit 0: BOOTP disable
"
::= { wtWebGraphAnalog57762Network 6 }
-- wtWebGraphAnalog57762HTTP Group
--------------------------------
wtWebGraphAnalog57762Startup OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded start page:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: Index.htm
Bit 2: Home.htm
Bit 3: User.htm
Only one page may be selected at a time."
::= { wtWebGraphAnalog57762HTTP 1 }
wtWebGraphAnalog57762GetHeaderEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If these bits are set, every answer of a short form GET question will be lead
by the IP-address and name of the device and/or a HTTP header:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-6: unused
Bit 1 : GET HTTP enable
Bit 0 : GET Header enable"
::= { wtWebGraphAnalog57762HTTP 2 }
wtWebGraphAnalog57762HttpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Definition of the standard HTML port (Default: 80)."
::= { wtWebGraphAnalog57762HTTP 3 }
-- wtWebGraphAnalog57762Mail Group
--------------------------------
wtWebGraphAnalog57762MailAdName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Device name for mail administration."
::= { wtWebGraphAnalog57762Mail 1 }
wtWebGraphAnalog57762MailReply OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reply address for the mail server."
::= { wtWebGraphAnalog57762Mail 2 }
wtWebGraphAnalog57762MailServer OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the mail server."
::= { wtWebGraphAnalog57762Mail 3 }
wtWebioAn1MailEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this bit to enable the sending of mails:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Mail enable"
::= { wtWebGraphAnalog57762Mail 4 }
wtWebGraphAnalog57762MailAuthentication OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selection of the authentication modi:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : POP3 before SMTP
Bit 1 : ESMTP, authentication
Bit 0 : SMTP, no authentication"
::= { wtWebGraphAnalog57762Mail 5 }
wtWebGraphAnalog57762MailAuthUser OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the user to be authenticated."
::= { wtWebGraphAnalog57762Mail 6 }
wtWebGraphAnalog57762MailAuthPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication password."
::= { wtWebGraphAnalog57762Mail 7 }
wtWebGraphAnalog57762MailPop3Server OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or Ip-address of the POP3 Servers."
::= { wtWebGraphAnalog57762Mail 8 }
-- wtWebGraphAnalog57762SNMP Group
--------------------------------
wtWebGraphAnalog57762SnmpCommunityStringRead OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read only"
::= { wtWebGraphAnalog57762SNMP 1 }
wtWebGraphAnalog57762SnmpCommunityStringReadWrite OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read / write"
::= { wtWebGraphAnalog57762SNMP 2 }
wtWebGraphAnalog57762SystemTrapManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the system trap."
::= { wtWebGraphAnalog57762SNMP 3 }
wtWebGraphAnalog57762SystemTrapEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2-7: unused"
::= { wtWebGraphAnalog57762SNMP 4 }
wtWebGraphAnalog57762SnmpEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set bit 0 to enable SNMP.
If disabled, the device did not respond to any SNMP requests.
Bit 1 decided wether the community string of read operations
is compared with the system password or not:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : SNMP enable"
::= { wtWebGraphAnalog57762SNMP 5 }
wtWebGraphAnalog57762SnmpCommunityStringTrap OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string send within traps."
::= { wtWebGraphAnalog57762SNMP 6 }
wtWebGraphAnalog57762SnmpSystemTrapManagerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the TCP server which accepts the system trap."
::= { wtWebGraphAnalog57762SNMP 7 }
-- wtWebGraphAnalog57762UDP Group
--------------------------------
wtWebGraphAnalog57762UdpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
port number must be unique within the device."
::= { wtWebGraphAnalog57762UDP 1 }
wtWebGraphAnalog57762UdpEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this bit to enable UDP support:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : UDP enable"
::= { wtWebGraphAnalog57762UDP 2 }
-- wtWebGraphAnalog57762Syslog Group
--------------------------------
wtWebGraphAnalog57762SyslogServerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
::= { wtWebGraphAnalog57762Syslog 1 }
wtWebGraphAnalog57762SyslogServerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Portnumber of the Syslog servers, default 514."
::= { wtWebGraphAnalog57762Syslog 2 }
wtWebGraphAnalog57762SyslogSystemMessagesEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2: Diag Messages
Bit 3-7: unused"
::= { wtWebGraphAnalog57762Syslog 3 }
wtWebGraphAnalog57762SyslogEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set bit 0to enable Syslog:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Syslog enable"
::= { wtWebGraphAnalog57762Syslog 4 }
-- wtWebGraphAnalog57762FTP Group
--------------------------------
wtWebGraphAnalog57762FTPServerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the FTP server, which accepts the FTP messages."
::= { wtWebGraphAnalog57762FTP 1 }
wtWebGraphAnalog57762FTPServerControlPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Portnumber of the control port of the FTP server, default 21."
::= { wtWebGraphAnalog57762FTP 2 }
wtWebGraphAnalog57762FTPUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: user name."
::= { wtWebGraphAnalog57762FTP 3 }
wtWebGraphAnalog57762FTPPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: user password."
::= { wtWebGraphAnalog57762FTP 4 }
wtWebGraphAnalog57762FTPAccount OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: name of account."
::= { wtWebGraphAnalog57762FTP 5 }
wtWebGraphAnalog57762FTPOption OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit 0 switches the FTP Server in Passiv-Mode,
the Client controls the data connection on its own:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : PASV enable"
::= { wtWebGraphAnalog57762FTP 6 }
wtWebGraphAnalog57762FTPEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Bit 0 to enable FTP:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : FTP enable"
::= { wtWebGraphAnalog57762FTP 7 }
-- wtWebGraphAnalog57762Language Group
--------------------------------
wtWebGraphAnalog57762LanguageSelect OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Language selection:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 2-7: unused
Bit 1 : English
Bit 0 : German"
::= { wtWebGraphAnalog57762Language 1 }
-- wtWebGraphAnalog57762Binary Group
--------------------------------
wtWebGraphAnalog57762BinaryModeCount OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of independent binary channels."
::= { wtWebGraphAnalog57762Binary 1 }
-- Binary Interface Table
wtWebGraphAnalog57762BinaryIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of indices."
::= { wtWebGraphAnalog57762Binary 2 }
wtWebGraphAnalog57762BinaryIfEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762BinaryIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Indices of the binary channels."
INDEX { wtWebGraphAnalog57762BinaryModeNo }
::= { wtWebGraphAnalog57762BinaryIfTable 1 }
WtWebGraphAnalog57762BinaryIfEntry ::= SEQUENCE {
wtWebGraphAnalog57762BinaryModeNo INTEGER
}
wtWebGraphAnalog57762BinaryModeNo OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of the binary channel."
::= { wtWebGraphAnalog57762BinaryIfEntry 1 }
-- Binary Table
--------------------------------
wtWebGraphAnalog57762BinaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of properties of the binary mode."
::= { wtWebGraphAnalog57762Binary 3 }
wtWebGraphAnalog57762BinaryEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762BinaryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Binary properties."
INDEX { wtWebGraphAnalog57762BinaryModeNo }
::= { wtWebGraphAnalog57762BinaryTable 1 }
WtWebGraphAnalog57762BinaryEntry ::= SEQUENCE {
wtWebGraphAnalog57762BinaryOperationMode OCTET STRING,
wtWebGraphAnalog57762BinaryTcpServerLocalPort INTEGER,
wtWebGraphAnalog57762BinaryTcpServerInputTrigger OCTET STRING,
wtWebGraphAnalog57762BinaryTcpServerApplicationMode OCTET STRING,
wtWebGraphAnalog57762BinaryTcpClientLocalPort INTEGER,
wtWebGraphAnalog57762BinaryTcpClientServerPort INTEGER,
wtWebGraphAnalog57762BinaryTcpClientServerIpAddr OCTET STRING,
wtWebGraphAnalog57762BinaryTcpClientServerPassword OCTET STRING,
wtWebGraphAnalog57762BinaryTcpClientInactivity INTEGER,
wtWebGraphAnalog57762BinaryTcpClientInputTrigger OCTET STRING,
wtWebGraphAnalog57762BinaryTcpClientInterval INTEGER,
wtWebGraphAnalog57762BinaryTcpClientApplicationMode OCTET STRING,
wtWebGraphAnalog57762BinaryUdpPeerLocalPort INTEGER,
wtWebGraphAnalog57762BinaryUdpPeerRemotePort INTEGER,
wtWebGraphAnalog57762BinaryUdpPeerRemoteIpAddr OCTET STRING,
wtWebGraphAnalog57762BinaryUdpPeerInputTrigger OCTET STRING,
wtWebGraphAnalog57762BinaryUdpPeerInterval INTEGER,
wtWebGraphAnalog57762BinaryUdpPeerApplicationMode OCTET STRING,
wtWebGraphAnalog57762BinaryConnectedPort INTEGER,
wtWebGraphAnalog57762BinaryConnectedIpAddr IpAddress,
wtWebGraphAnalog57762BinaryTcpServerClientHttpPort INTEGER,
wtWebGraphAnalog57762BinaryTcpClientServerHttpPort INTEGER,
wtWebGraphAnalog57762BinaryTcpServerHysteresis1 OCTET STRING,
wtWebGraphAnalog57762BinaryTcpServerHysteresis2 OCTET STRING,
wtWebGraphAnalog57762BinaryTcpClientHysteresis1 OCTET STRING,
wtWebGraphAnalog57762BinaryTcpClientHysteresis2 OCTET STRING,
wtWebGraphAnalog57762BinaryUdpPeerHysteresis1 OCTET STRING,
wtWebGraphAnalog57762BinaryUdpPeerHysteresis2 OCTET STRING,
wtWebGraphAnalog57762BinaryTcpClientServerUserName OCTET STRING
}
wtWebGraphAnalog57762BinaryOperationMode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
Bit 0 : TCP Server"
::= { wtWebGraphAnalog57762BinaryEntry 1 }
wtWebGraphAnalog57762BinaryTcpServerLocalPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual)."
::= { wtWebGraphAnalog57762BinaryEntry 2 }
wtWebGraphAnalog57762BinaryTcpServerInputTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input states.
If a bit is set (1), a change of state on the corresponding input
triggers a transmission. If the bit is not set (0), no transmission
takes place.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 0-1: Analog inputs 0-1"
::= { wtWebGraphAnalog57762BinaryEntry 3 }
wtWebGraphAnalog57762BinaryTcpServerApplicationMode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box Slave
Bit 1 : Compatible 50xxx
Bit 0 : Default"
::= { wtWebGraphAnalog57762BinaryEntry 4 }
wtWebGraphAnalog57762BinaryTcpClientLocalPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual)."
::= { wtWebGraphAnalog57762BinaryEntry 5 }
wtWebGraphAnalog57762BinaryTcpClientServerPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero."
::= { wtWebGraphAnalog57762BinaryEntry 6 }
wtWebGraphAnalog57762BinaryTcpClientServerIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0."
::= { wtWebGraphAnalog57762BinaryEntry 7 }
wtWebGraphAnalog57762BinaryTcpClientServerPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists."
::= { wtWebGraphAnalog57762BinaryEntry 8 }
wtWebGraphAnalog57762BinaryTcpClientInactivity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled."
::= { wtWebGraphAnalog57762BinaryEntry 9 }
wtWebGraphAnalog57762BinaryTcpClientInputTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input states.
If a bit is set (1), a change of state on the corresponding input
triggers a transmission. If the bit is not set (0), no transmission
takes place.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 0-1: Analog inputs 0-1"
::= { wtWebGraphAnalog57762BinaryEntry 10 }
wtWebGraphAnalog57762BinaryTcpClientInterval OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending."
::= { wtWebGraphAnalog57762BinaryEntry 11 }
wtWebGraphAnalog57762BinaryTcpClientApplicationMode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compatible 50xxx
Bit 0 : Default"
::= { wtWebGraphAnalog57762BinaryEntry 12 }
wtWebGraphAnalog57762BinaryUdpPeerLocalPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual)."
::= { wtWebGraphAnalog57762BinaryEntry 13 }
wtWebGraphAnalog57762BinaryUdpPeerRemotePort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero."
::= { wtWebGraphAnalog57762BinaryEntry 14 }
wtWebGraphAnalog57762BinaryUdpPeerRemoteIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0."
::= { wtWebGraphAnalog57762BinaryEntry 15 }
wtWebGraphAnalog57762BinaryUdpPeerInputTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input states.
If a bit is set (1), a change of state on the corresponding input
triggers a transmission. If the bit is not set (0), no transmission
takes place.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 0-1: Analog inputs 0-1"
::= { wtWebGraphAnalog57762BinaryEntry 16 }
wtWebGraphAnalog57762BinaryUdpPeerInterval OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending."
::= { wtWebGraphAnalog57762BinaryEntry 17 }
wtWebGraphAnalog57762BinaryUdpPeerApplicationMode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compatible 50xxx
Bit 0 : Default"
::= { wtWebGraphAnalog57762BinaryEntry 18 }
wtWebGraphAnalog57762BinaryConnectedPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read."
::= { wtWebGraphAnalog57762BinaryEntry 19 }
wtWebGraphAnalog57762BinaryConnectedIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read."
::= { wtWebGraphAnalog57762BinaryEntry 20 }
wtWebGraphAnalog57762BinaryTcpServerClientHttpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx."
::= { wtWebGraphAnalog57762BinaryEntry 21 }
wtWebGraphAnalog57762BinaryTcpClientServerHttpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port."
::= { wtWebGraphAnalog57762BinaryEntry 22 }
wtWebGraphAnalog57762BinaryTcpServerHysteresis1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger.
With a hysteresis of zero any change will be transmitted."
::= { wtWebGraphAnalog57762BinaryEntry 23 }
wtWebGraphAnalog57762BinaryTcpServerHysteresis2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger.
With a hysteresis of zero any change will be transmitted."
::= { wtWebGraphAnalog57762BinaryEntry 24 }
wtWebGraphAnalog57762BinaryTcpClientHysteresis1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger.
With a hysteresis of zero any change will be transmitted."
::= { wtWebGraphAnalog57762BinaryEntry 25 }
wtWebGraphAnalog57762BinaryTcpClientHysteresis2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger.
With a hysteresis of zero any change will be transmitted."
::= { wtWebGraphAnalog57762BinaryEntry 26 }
wtWebGraphAnalog57762BinaryUdpPeerHysteresis1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger.
With a hysteresis of zero any change will be transmitted."
::= { wtWebGraphAnalog57762BinaryEntry 27 }
wtWebGraphAnalog57762BinaryUdpPeerHysteresis2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger.
With a hysteresis of zero any change will be transmitted."
::= { wtWebGraphAnalog57762BinaryEntry 28 }
wtWebGraphAnalog57762BinaryTcpClientServerUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Building a connection may be protected by a specific
user name within the server. Enter the user name
to establish the connection, if a user name entry
exists."
::= { wtWebGraphAnalog57762BinaryEntry 29 }
-- wtWebGraphAnalog57762MQTT Group
--------------------------------
wtWebGraphAnalog57762MQTTEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit 7 schaltet MQTT frei:
Octet 1: ungenutzt
Octet 2: ungenutzt
Octet 3: ungenutzt
Octet 4:
Bit 0-6: ungenutzt
Bit 7 : MQTT enable"
::= { wtWebGraphAnalog57762MQTT 1 }
wtWebGraphAnalog57762MQTTBrockerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP-address of the MQTT-Server."
::= { wtWebGraphAnalog57762MQTT 2 }
wtWebGraphAnalog57762MQTTUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT login user name."
::= { wtWebGraphAnalog57762MQTT 3 }
wtWebGraphAnalog57762MQTTPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT login password."
::= { wtWebGraphAnalog57762MQTT 4 }
wtWebGraphAnalog57762MQTTLocalPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local port number."
::= { wtWebGraphAnalog57762MQTT 5 }
wtWebGraphAnalog57762MQTTBrokerServerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT Server port number."
::= { wtWebGraphAnalog57762MQTT 6 }
wtWebGraphAnalog57762MQTTInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ping intervall, if no data has to be send: time in seconds."
::= { wtWebGraphAnalog57762MQTT 7 }
wtWebGraphAnalog57762MQTTLastWillEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit 0 activate MQTT LastWill message:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : MQTT Last will enable"
::= { wtWebGraphAnalog57762MQTT 8 }
wtWebGraphAnalog57762MQTTLastWillTopic OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT Last Will Topic."
::= { wtWebGraphAnalog57762MQTT 9 }
wtWebGraphAnalog57762MQTTLastWillMsg OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT Last Will message."
::= { wtWebGraphAnalog57762MQTT 10 }
wtWebGraphAnalog57762MQTTLastWillQoS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded MQTT Publish QoS:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: QoS 0
Bit 1: QoS 1
Bit 2: QoS 2
Bit 3-7:unused"
::= { wtWebGraphAnalog57762MQTT 11 }
wtWebGraphAnalog57762MQTTLastWillRetain OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded MQTT Publish Retain properties:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : retain enable
Bit 1-7 : unused"
::= { wtWebGraphAnalog57762MQTT 12 }
wtWebGraphAnalog57762MQTTLastWillConnectEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit 0 activate MQTT LastWill Connect message:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : MQTT Last will connect message enable"
::= { wtWebGraphAnalog57762MQTT 13 }
wtWebGraphAnalog57762MQTTLastWillConnectMsg OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT Last Will Connect message will be send with the QoS and Retain settings
of the LastWill message."
::= { wtWebGraphAnalog57762MQTT 14 }
-- wtWebGraphAnalog57762REST Group
--------------------------------
wtWebGraphAnalog57762RESTEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit 0 activates REST :
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : REST enable"
::= { wtWebGraphAnalog57762REST 1 }
wtWebGraphAnalog57762RESTDigestAuthEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit 0 activates Digest-Authentification:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Digest Auth enable"
::= { wtWebGraphAnalog57762REST 2 }
-- wtWebGraphAnalog57762Datalogger Group
--------------------------------
wtWebGraphAnalog57762LoggerTimebase OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalog57762Datalogger-15Sec(1),
wtWebGraphAnalog57762Datalogger-30Sec(2),
wtWebGraphAnalog57762Datalogger-1Min(3),
wtWebGraphAnalog57762Datalogger-5Min(4),
wtWebGraphAnalog57762Datalogger-15Min(5),
wtWebGraphAnalog57762Datalogger-60Min(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time base of the data logger"
::= { wtWebGraphAnalog57762Datalogger 1 }
wtWebGraphAnalog57762LoggerSensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalog57762Datalogger 2 }
-- wtWebGraphAnalog57762Alarm Group
----------------------------
wtWebGraphAnalog57762AlarmCount OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of independent alarms."
::= { wtWebGraphAnalog57762Alarm 1 }
-- Alarm Interface Table
wtWebGraphAnalog57762AlarmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of alarm indices."
::= { wtWebGraphAnalog57762Alarm 2 }
wtWebGraphAnalog57762AlarmIfEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the alarms."
INDEX { wtWebGraphAnalog57762AlarmNo }
::= { wtWebGraphAnalog57762AlarmIfTable 1 }
WtWebGraphAnalog57762AlarmIfEntry ::= SEQUENCE {
wtWebGraphAnalog57762AlarmNo INTEGER
}
wtWebGraphAnalog57762AlarmNo OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm number."
::= { wtWebGraphAnalog57762AlarmIfEntry 1 }
-- Alarm Table
wtWebGraphAnalog57762AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the alarm number."
::= { wtWebGraphAnalog57762Alarm 3 }
wtWebGraphAnalog57762AlarmEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm parameters of the individual alarms."
INDEX { wtWebGraphAnalog57762AlarmNo }
::= { wtWebGraphAnalog57762AlarmTable 1 }
WtWebGraphAnalog57762AlarmEntry ::= SEQUENCE {
wtWebGraphAnalog57762AlarmTrigger OCTET STRING,
wtWebGraphAnalog57762AlarmMin1 OCTET STRING,
wtWebGraphAnalog57762AlarmMax1 OCTET STRING,
wtWebGraphAnalog57762AlarmHysteresis1 OCTET STRING,
wtWebGraphAnalog57762AlarmDelay OCTET STRING,
wtWebGraphAnalog57762AlarmInterval OCTET STRING,
wtWebGraphAnalog57762AlarmEnable OCTET STRING,
wtWebGraphAnalog57762AlarmEMailAddr OCTET STRING,
wtWebGraphAnalog57762AlarmMailSubject OCTET STRING,
wtWebGraphAnalog57762AlarmMailText OCTET STRING,
wtWebGraphAnalog57762AlarmManagerIP OCTET STRING,
wtWebGraphAnalog57762AlarmTrapText OCTET STRING,
wtWebGraphAnalog57762AlarmMailOptions OCTET STRING,
wtWebGraphAnalog57762AlarmTcpIpAddr OCTET STRING,
wtWebGraphAnalog57762AlarmTcpPort INTEGER,
wtWebGraphAnalog57762AlarmTcpText OCTET STRING,
wtWebGraphAnalog57762AlarmClearMailSubject OCTET STRING,
wtWebGraphAnalog57762AlarmClearMailText OCTET STRING,
wtWebGraphAnalog57762AlarmClearTrapText OCTET STRING,
wtWebGraphAnalog57762AlarmClearTcpText OCTET STRING,
wtWebGraphAnalog57762AlarmMin2 OCTET STRING,
wtWebGraphAnalog57762AlarmMax2 OCTET STRING,
wtWebGraphAnalog57762AlarmHysteresis2 OCTET STRING,
wtWebGraphAnalog57762AlarmSyslogIpAddr OCTET STRING,
wtWebGraphAnalog57762AlarmSyslogPort INTEGER,
wtWebGraphAnalog57762AlarmSyslogText OCTET STRING,
wtWebGraphAnalog57762AlarmSyslogClearText OCTET STRING,
wtWebGraphAnalog57762AlarmFtpDataPort OCTET STRING,
wtWebGraphAnalog57762AlarmFtpFileName OCTET STRING,
wtWebGraphAnalog57762AlarmFtpText OCTET STRING,
wtWebGraphAnalog57762AlarmFtpClearText OCTET STRING,
wtWebGraphAnalog57762AlarmFtpOption OCTET STRING,
wtWebGraphAnalog57762AlarmTimerCron OCTET STRING,
wtWebGraphAnalog57762AlarmDeltaTemp OCTET STRING,
wtWebGraphAnalog57762AlarmName OCTET STRING,
wtWebGraphAnalog57762AlarmActive OCTET STRING,
wtWebGraphAnalog57762AlarmHttpReqAuthEnable OCTET STRING,
wtWebGraphAnalog57762AlarmHttpReqAuthUser OCTET STRING,
wtWebGraphAnalog57762AlarmHttpReqAuthPassword OCTET STRING,
wtWebGraphAnalog57762AlarmHttpReqSetUrl OCTET STRING,
wtWebGraphAnalog57762AlarmHttpReqClearUrl OCTET STRING,
wtWebGraphAnalog57762AlarmHttpReqServerPort INTEGER,
wtWebGraphAnalog57762AlarmMqttTopicPath OCTET STRING,
wtWebGraphAnalog57762AlarmMqttTopicSetTopic OCTET STRING,
wtWebGraphAnalog57762AlarmMqttTopicClear OCTET STRING,
wtWebGraphAnalog57762AlarmSensorLostSelection OCTET STRING,
wtWebGraphAnalog57762AlarmLimitWindow OCTET STRING,
wtWebGraphAnalog57762AlarmSnmpManagerPort INTEGER,
wtWebGraphAnalog57762AlarmMqttQoS OCTET STRING,
wtWebGraphAnalog57762AlarmMqttRetain OCTET STRING
}
wtWebGraphAnalog57762AlarmTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalog57762AlarmEntry 1 }
wtWebGraphAnalog57762AlarmMin1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum sensor 1 with maximum 3 decimal places."
::= { wtWebGraphAnalog57762AlarmEntry 2 }
wtWebGraphAnalog57762AlarmMax1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum sensor 1 with maximum 3 decimal places."
::= { wtWebGraphAnalog57762AlarmEntry 3 }
wtWebGraphAnalog57762AlarmHysteresis1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
with maximum 3 decimal places."
::= { wtWebGraphAnalog57762AlarmEntry 4 }
wtWebGraphAnalog57762AlarmDelay OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes)."
::= { wtWebGraphAnalog57762AlarmEntry 5 }
wtWebGraphAnalog57762AlarmInterval OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send interval for alarm messages."
::= { wtWebGraphAnalog57762AlarmEntry 6 }
wtWebGraphAnalog57762AlarmEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable"
::= { wtWebGraphAnalog57762AlarmEntry 7 }
wtWebGraphAnalog57762AlarmEMailAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E-Mail address for sending the alarm mail to."
::= { wtWebGraphAnalog57762AlarmEntry 8 }
wtWebGraphAnalog57762AlarmMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm mail."
::= { wtWebGraphAnalog57762AlarmEntry 9 }
wtWebGraphAnalog57762AlarmMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time."
::= { wtWebGraphAnalog57762AlarmEntry 10 }
wtWebGraphAnalog57762AlarmManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the SNMP Manager which accepts the trap."
::= { wtWebGraphAnalog57762AlarmEntry 11 }
wtWebGraphAnalog57762AlarmTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebGraphAnalog57762AlarmEntry 12 }
wtWebGraphAnalog57762AlarmMailOptions OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused"
::= { wtWebGraphAnalog57762AlarmEntry 13 }
wtWebGraphAnalog57762AlarmTcpIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the trap."
::= { wtWebGraphAnalog57762AlarmEntry 14 }
wtWebGraphAnalog57762AlarmTcpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the TCP server which accepts the trap."
::= { wtWebGraphAnalog57762AlarmEntry 15 }
wtWebGraphAnalog57762AlarmTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebGraphAnalog57762AlarmEntry 16 }
wtWebGraphAnalog57762AlarmClearMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm clear mail."
::= { wtWebGraphAnalog57762AlarmEntry 17 }
wtWebGraphAnalog57762AlarmClearMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time."
::= { wtWebGraphAnalog57762AlarmEntry 18 }
wtWebGraphAnalog57762AlarmClearTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebGraphAnalog57762AlarmEntry 19 }
wtWebGraphAnalog57762AlarmClearTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebGraphAnalog57762AlarmEntry 20 }
wtWebGraphAnalog57762AlarmMin2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum sensor 2 with maximum 3 decimal places."
::= { wtWebGraphAnalog57762AlarmEntry 21 }
wtWebGraphAnalog57762AlarmMax2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum sensor 2 with maximum 2 decimal places."
::= { wtWebGraphAnalog57762AlarmEntry 22 }
wtWebGraphAnalog57762AlarmHysteresis2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hysterese rel. sensor 2 with maximum 3 decimal places."
::= { wtWebGraphAnalog57762AlarmEntry 23 }
wtWebGraphAnalog57762AlarmSyslogIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the syslog server to which the Webio device should send syslog messages."
::= { wtWebGraphAnalog57762AlarmEntry 24 }
wtWebGraphAnalog57762AlarmSyslogPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the syslog server to which the Webio device should send syslog messages."
::= { wtWebGraphAnalog57762AlarmEntry 25 }
wtWebGraphAnalog57762AlarmSyslogText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body."
::= { wtWebGraphAnalog57762AlarmEntry 26 }
wtWebGraphAnalog57762AlarmSyslogClearText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message."
::= { wtWebGraphAnalog57762AlarmEntry 27 }
wtWebGraphAnalog57762AlarmFtpDataPort OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
::= { wtWebGraphAnalog57762AlarmEntry 28 }
wtWebGraphAnalog57762AlarmFtpFileName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the file including path informations."
::= { wtWebGraphAnalog57762AlarmEntry 29 }
wtWebGraphAnalog57762AlarmFtpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Message text to store on the FTP server."
::= { wtWebGraphAnalog57762AlarmEntry 30 }
wtWebGraphAnalog57762AlarmFtpClearText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear message to store on the FTP server."
::= { wtWebGraphAnalog57762AlarmEntry 31 }
wtWebGraphAnalog57762AlarmFtpOption OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STORE
Bit 1 : APPEND
Bit 2-7: unused"
::= { wtWebGraphAnalog57762AlarmEntry 32 }
wtWebGraphAnalog57762AlarmTimerCron OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab.
The activation time of the report is defined by a single start time stamp.
Each time stamp contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger an action, weekday and day of month
are interpreted separatley.
1: Minutes Range 0-59
2. Hours Range 0-23, 0 is midnight
3: Day of month Range 1-31
4: Month Range 1-12
5: Weekday Range 0-6, 0 is sunday
Syntax for every field:
- an asterix (*) enables every possible setting of a field
- single numbers seperated by commas (i.e.: 2,14,22)
- a partition within the allowed range (i.e.: 1-5)
- step size within a partition of the allowed range (i.e.: 0-59/2 every second minute)."
::= { wtWebGraphAnalog57762AlarmEntry 33 }
-- __JB__
wtWebGraphAnalog57762AlarmName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alert name"
::= { wtWebGraphAnalog57762AlarmEntry 39 }
-- __JB__
wtWebGraphAnalog57762AlarmActive OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alert active
1 = ON
0 = OFF"
::= { wtWebGraphAnalog57762AlarmEntry 40 }
wtWebGraphAnalog57762AlarmHttpReqAuthEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options, select only one option at the same time:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable"
::= { wtWebGraphAnalog57762AlarmEntry 61 }
wtWebGraphAnalog57762AlarmHttpReqAuthUser OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP Request: User"
::= { wtWebGraphAnalog57762AlarmEntry 62 }
wtWebGraphAnalog57762AlarmHttpReqAuthPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP Request: Password"
::= { wtWebGraphAnalog57762AlarmEntry 63 }
wtWebGraphAnalog57762AlarmHttpReqSetUrl OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP Request: Set URL"
::= { wtWebGraphAnalog57762AlarmEntry 64 }
wtWebGraphAnalog57762AlarmHttpReqClearUrl OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP Request: Clear URL"
::= { wtWebGraphAnalog57762AlarmEntry 65 }
wtWebGraphAnalog57762AlarmHttpReqServerPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"HTTP Request: Server Port"
::= { wtWebGraphAnalog57762AlarmEntry 66 }
wtWebGraphAnalog57762AlarmMqttTopicPath OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT Publish: Topic path"
::= { wtWebGraphAnalog57762AlarmEntry 67 }
wtWebGraphAnalog57762AlarmMqttTopicSetTopic OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT Publish: Topic SET message"
::= { wtWebGraphAnalog57762AlarmEntry 68 }
wtWebGraphAnalog57762AlarmMqttTopicClear OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQTT Publish: Topic CLEAR message"
::= { wtWebGraphAnalog57762AlarmEntry 69 }
wtWebGraphAnalog57762AlarmSensorLostSelection OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Sensor 0"
::= { wtWebGraphAnalog57762AlarmEntry 70 }
wtWebGraphAnalog57762AlarmLimitWindow OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE
the alarm is generated when the measured value is lower than the minimum value
or greater than the maximum value.
Binary coded options, select only one option at the same time:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : inside window
Bit 0 : outside window"
::= { wtWebGraphAnalog57762AlarmEntry 71 }
wtWebGraphAnalog57762AlarmSnmpManagerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the SNMP Manager to which the Webio device should send SNMP traps."
::= { wtWebGraphAnalog57762AlarmEntry 76 }
wtWebGraphAnalog57762AlarmMqttQoS OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: QoS 0
Bit 1: QoS 1
Bit 2: QoS 2
Bit 3-7:unused"
::= { wtWebGraphAnalog57762AlarmEntry 77 }
wtWebGraphAnalog57762AlarmMqttRetain OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : retain enable
Bit 1-7 : unused"
::= { wtWebGraphAnalog57762AlarmEntry 78 }
-- wtWebGraphAnalog57762GraphicsBase Group
----------------------------
wtWebGraphAnalog57762GraphicsBaseEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the viewing options of the graphic:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Auto scroll enable
Bit 1 : Show table
Bit 2 : Show graph
Bit 3 : Show control buttons
Bit 4 : Show config menu
Bit 5-7: unused"
::= { wtWebGraphAnalog57762GraphicsBase 1 }
wtWebGraphAnalog57762GraphicsBaseWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the width of the graphic in pixels."
::= { wtWebGraphAnalog57762GraphicsBase 2 }
wtWebGraphAnalog57762GraphicsBaseHeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the height of the graphic in pixels."
::= { wtWebGraphAnalog57762GraphicsBase 3 }
wtWebGraphAnalog57762GraphicsBaseFrameColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame color definition in RGB."
::= { wtWebGraphAnalog57762GraphicsBase 4 }
wtWebGraphAnalog57762GraphicsBaseBackgroundColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Background color definition in RGB."
::= { wtWebGraphAnalog57762GraphicsBase 5 }
wtWebGraphAnalog57762GraphicsBasePollingrate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the pollingrate in seconds,
which defines the refreshing intervall of the graphic."
::= { wtWebGraphAnalog57762GraphicsBase 6 }
-- wtWebGraphAnalog57762GraphicsSelect Group
----------------------------
wtWebGraphAnalog57762GraphicsSelectDisplaySensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded sensor selection:
only selected sensors will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalog57762GraphicsSelect 1 }
wtWebGraphAnalog57762GraphicsSelectDisplayShowExtrem OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded sensor selection:
only selected sensors will be shown with minima and maxima:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalog57762GraphicsSelect 2 }
-- Graph Sensor Color Table
wtWebGraphAnalog57762SensorColor2Table OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762SensorColor2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensor colors for the praphical presentation."
::= { wtWebGraphAnalog57762GraphicsSelect 3 }
wtWebGraphAnalog57762SensorColor2Entry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762SensorColor2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the sensors."
INDEX { wtWebGraphAnalog57762SensorNo }
::= { wtWebGraphAnalog57762SensorColor2Table 1 }
WtWebGraphAnalog57762SensorColor2Entry ::= SEQUENCE {
wtWebGraphAnalog57762GraphicsSensorColor OCTET STRING,
wtWebGraphAnalog57762GraphicsSelectScale OCTET STRING
}
wtWebGraphAnalog57762GraphicsSensorColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Color of the sensors at the praphical presention."
::= { wtWebGraphAnalog57762SensorColor2Entry 1 }
wtWebGraphAnalog57762GraphicsSelectScale OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Assignes one of 4 scales to a sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Use Scale 1
Bit 1 : Use Scale 2
Bit 2-7: unused"
::= { wtWebGraphAnalog57762SensorColor2Entry 2 }
-- wtWebGraphAnalog57762GraphicsScale Group
----------------------------
wtWebGraphAnalog57762GraphicsScaleAutoScaleEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the Auto Scale Mode:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto scale enable
Bit 1 : Scale 2 Auto scale enable
Bit 2-7: unused"
::= { wtWebGraphAnalog57762GraphicsScale 1 }
wtWebGraphAnalog57762GraphicsScaleAutoFitEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the Auto Fit Mode::
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto fit enable
Bit 1 : Scale 2 Auto fit enable
Bit 2-7: unused"
::= { wtWebGraphAnalog57762GraphicsScale 2 }
wtWebGraphAnalog57762GraphicsScale1Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Minimum."
::= { wtWebGraphAnalog57762GraphicsScale 3 }
wtWebGraphAnalog57762GraphicsScale2Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Minimum."
::= { wtWebGraphAnalog57762GraphicsScale 4 }
wtWebGraphAnalog57762GraphicsScale1Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Maximum."
::= { wtWebGraphAnalog57762GraphicsScale 7 }
wtWebGraphAnalog57762GraphicsScale2Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Maximum."
::= { wtWebGraphAnalog57762GraphicsScale 8 }
wtWebGraphAnalog57762GraphicsScale1Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Unit."
::= { wtWebGraphAnalog57762GraphicsScale 11 }
wtWebGraphAnalog57762GraphicsScale2Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Unit."
::= { wtWebGraphAnalog57762GraphicsScale 12 }
-- wtWebGraphAnalog57762Ports Group
----------------------------
-- Table
wtWebGraphAnalog57762PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalog57762PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the sensor number."
::= { wtWebGraphAnalog57762Ports 1 }
wtWebGraphAnalog57762PortEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalog57762PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Sensor parameters for the individual sensors."
INDEX { wtWebGraphAnalog57762SensorNo }
::= { wtWebGraphAnalog57762PortTable 1 }
WtWebGraphAnalog57762PortEntry ::= SEQUENCE {
wtWebGraphAnalog57762PortName OCTET STRING,
wtWebGraphAnalog57762PortText OCTET STRING,
wtWebGraphAnalog57762PortOffset1 OCTET STRING,
wtWebGraphAnalog57762SetPoint1 OCTET STRING,
wtWebGraphAnalog57762PortOffset2 OCTET STRING,
wtWebGraphAnalog57762SetPoint2 OCTET STRING,
wtWebGraphAnalog57762PortComment OCTET STRING,
wtWebGraphAnalog57762PortSensorSelect OCTET STRING,
wtWebGraphAnalog57762PortUnit OCTET STRING,
wtWebGraphAnalog57762PortScale0 OCTET STRING,
wtWebGraphAnalog57762PortScale100 OCTET STRING,
wtWebGraphAnalog57762PortOutputMode OCTET STRING,
wtWebGraphAnalog57762PortInputMode OCTET STRING,
wtWebGraphAnalog57762PortPresetValue OCTET STRING
}
wtWebGraphAnalog57762PortName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the sensor."
::= { wtWebGraphAnalog57762PortEntry 1 }
wtWebGraphAnalog57762PortText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the sensor."
::= { wtWebGraphAnalog57762PortEntry 2 }
wtWebGraphAnalog57762PortOffset1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1."
::= { wtWebGraphAnalog57762PortEntry 3 }
wtWebGraphAnalog57762SetPoint1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places."
::= { wtWebGraphAnalog57762PortEntry 4 }
wtWebGraphAnalog57762PortOffset2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2."
::= { wtWebGraphAnalog57762PortEntry 5 }
wtWebGraphAnalog57762SetPoint2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places."
::= { wtWebGraphAnalog57762PortEntry 6 }
wtWebGraphAnalog57762PortComment OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: informations of date, name of operator, reference devices."
::= { wtWebGraphAnalog57762PortEntry 7 }
wtWebGraphAnalog57762PortSensorSelect OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options for sensor 1:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : 0-20mA (default)
Bit 1 : 4-20mA
Bit 2 : Disconnect
Bit 3-7: unused"
::= { wtWebGraphAnalog57762PortEntry 8 }
wtWebGraphAnalog57762PortUnit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed unit."
::= { wtWebGraphAnalog57762PortEntry 9 }
wtWebGraphAnalog57762PortScale0 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed value in 1/1000 at 0% full scale range.
Range: -999999.999 to 999999.999"
::= { wtWebGraphAnalog57762PortEntry 10 }
wtWebGraphAnalog57762PortScale100 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed value in 1/1000 at 100% full scale range.
Range: -999999.999 to 999999.999"
::= { wtWebGraphAnalog57762PortEntry 11 }
wtWebGraphAnalog57762PortOutputMode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected. If an output mode is selected,
Bit 2 in wtWebGraphAnalog57762PortInputMode will be set automatically.
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 6-7: unused
Bit 5 : Output OFF
Bit 4 : Binary 2
Bit 3 : Binary 1
Bit 2 : SNMP
Bit 1 : UDP ASCII
Bit 0 : HTTP"
::= { wtWebGraphAnalog57762PortEntry 12 }
wtWebGraphAnalog57762PortInputMode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This binary coded input mode defines the individual operation mode for any
input. More than one mode must not be selected. If an input mode is selected,
Bit 5 in wtWebGraphAnalog57762PortOutputMode will be set automatically.
The OCTETS are interpreted bit-by-bit,Bit 0 corresponds to the LSB.
OCTET 1: ungenutzt
OCTET 2: ungenutzt
OCTET 3: ungenutzt
OCTET 4: Bit 3-7: unused
Bit 2 : I-Output
Bit 1 : I-Input, active
Bit 0 : I-Input, passive"
::= { wtWebGraphAnalog57762PortEntry 13 }
wtWebGraphAnalog57762PortPresetValue OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value will be set after reset or initialisation."
::= { wtWebGraphAnalog57762PortEntry 16 }
-- wtWebGraphAnalog57762Manufact Group
----------------------------
wtWebGraphAnalog57762MfName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer company name"
::= { wtWebGraphAnalog57762Manufact 1 }
wtWebGraphAnalog57762MfAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer address."
::= { wtWebGraphAnalog57762Manufact 2 }
wtWebGraphAnalog57762MfHotline OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer hotline."
::= { wtWebGraphAnalog57762Manufact 3 }
wtWebGraphAnalog57762MfInternet OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer Internet address."
::= { wtWebGraphAnalog57762Manufact 4 }
wtWebGraphAnalog57762MfDeviceTyp OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer device name (model number)."
::= { wtWebGraphAnalog57762Manufact 5 }
wtWebGraphAnalog57762MfOrderNo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer part number."
::= { wtWebGraphAnalog57762Manufact 6 }
-- wtWebGraphAnalog57762Diag Group
----------------------------
wtWebGraphAnalog57762DiagErrorCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of entries in the error memory."
::= { wtWebGraphAnalog57762Diag 1 }
wtWebGraphAnalog57762DiagBinaryError OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error causes coded bit-by-bit."
::= { wtWebGraphAnalog57762Diag 2 }
wtWebGraphAnalog57762DiagErrorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this variable is used as an index to read
an error massege from wtWebGraphAnalog57762DiagErrorMessage.
Errors are numbered from 1 to wtWebGraphAnalog57762DiagErrorCount.
Writing a valid value into this variable, making the appropriate
message readable from wtWebGraphAnalog57762DiagErrorMessage."
::= { wtWebGraphAnalog57762Diag 3 }
wtWebGraphAnalog57762DiagErrorMessage OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Using wtWebGraphAnalog57762DiagErrorIndex as an index, the appropriate message is available."
::= { wtWebGraphAnalog57762Diag 4 }
wtWebGraphAnalog57762DiagErrorClear OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Writing 1 into this variable clears all diagnosis messages."
::= { wtWebGraphAnalog57762Diag 5 }
-- TRAP DEFINITIONS
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
wtWebGraphAnalog57762Alert1 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 31
wtWebGraphAnalog57762Alert2 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 32
wtWebGraphAnalog57762Alert3 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 33
wtWebGraphAnalog57762Alert4 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 34
wtWebGraphAnalog57762Alert5 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 35
wtWebGraphAnalog57762Alert6 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 36
wtWebGraphAnalog57762Alert7 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 37
wtWebGraphAnalog57762Alert8 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 38
wtWebGraphAnalog57762Alert9 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Release Alarm 1"
--#SUMMARY "Release Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 91
wtWebGraphAnalog57762Alert10 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Release Alarm 2"
--#SUMMARY "Release Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 92
wtWebGraphAnalog57762Alert11 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Release Alarm 3"
--#SUMMARY "Release Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 93
wtWebGraphAnalog57762Alert12 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Release Alarm 4"
--#SUMMARY "Release Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 94
wtWebGraphAnalog57762Alert13 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Release Alarm 5"
--#SUMMARY "Release Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 95
wtWebGraphAnalog57762Alert14 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Release Alarm 6"
--#SUMMARY "Release Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 96
wtWebGraphAnalog57762Alert15 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Release Alarm 7"
--#SUMMARY "Release Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 97
wtWebGraphAnalog57762Alert16 TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Release Alarm 8"
--#SUMMARY "Release Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 98
wtWebGraphAnalog57762AlertReport TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when the report was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Report"
--#SUMMARY "Report: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 39
wtWebGraphAnalog57762AlertDiag TRAP-TYPE
ENTERPRISE wtWebGraphAnalog57762
VARIABLES {
wtWebGraphAnalog57762DiagErrorIndex,
wtWebGraphAnalog57762DiagErrorMessage
}
DESCRIPTION
"This SNMP trap is generated when a diagnosis/error message was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Web-IO Analog-InOut Diagnose Error"
--#SUMMARY "Diagnose error index: %d, Message: %s."
--#ARGUMENTS {0,1}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
::= 110
END