-- Filename: ut-epon-4000-fault.mib
|
|
-- Description: Contains iSwitch MIB Extension.
|
|
-- MIB Version: 1.00
|
|
--
|
|
-- Copyright (C) 2001 by UTStarcom, Inc. All rights reserved.
|
|
-- Reproduction of this document is authorized on the condition that
|
|
-- the foregoing copyright notice is included.
|
|
--
|
|
-- NOTE: The contents of this document are subject to change without notice
|
|
-- *****************************************************************************
|
|
|
|
-- *****************************************************************************
|
|
-- Version: $Id: $
|
|
-- Last Modified: $DateTime: $
|
|
-- Change List #: $Change: $
|
|
-- *****************************************************************************
|
|
|
|
UTEPON4000FAULT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE,
|
|
OBJECT-TYPE, IpAddress FROM SNMPv2-SMI
|
|
Counter, TimeTicks FROM RFC1155-SMI
|
|
RowStatus, TruthValue FROM SNMPv2-TC
|
|
ifIndex, DisplayString FROM RFC1213-MIB
|
|
MacAddress, BridgeId, Timeout FROM BRIDGE-MIB
|
|
utsGeponBBS4000 FROM UTS-BBS-COMMON-MIB
|
|
utsDot3Security8021xRadiusSvrPrimaryOnuAuthIP FROM UTSECURITY-MIB
|
|
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmSeqNo,
|
|
alarmType,
|
|
alarmSeverity,
|
|
alarmErrorData,
|
|
alarmErrorDataStr,
|
|
alarmIgmpIIf,
|
|
alarmIgmpGrpAddr,
|
|
alarmIgmpOIf,
|
|
alarmIgmpProxyStatus,
|
|
alarmFanNumber,
|
|
alarmTaskName,
|
|
alarmResourceInt,
|
|
alarmDiagStatus,
|
|
alarmRdsSvrIp,
|
|
alarmPowerSlotStatus,
|
|
alarmPowerSlotNumber,
|
|
alarmRdsSvrIdx,
|
|
alarmBBS4000ModuleType,
|
|
alarmSessionId FROM EPONOAMINIT-ALARM-MIB
|
|
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType FROM UTS-FAULT-MIB;
|
|
|
|
|
|
|
|
utsGeponBBS4000Fault MODULE-IDENTITY
|
|
LAST-UPDATED "200511211045Z" -- Wed Nov. 21 10:45:00 2005
|
|
ORGANIZATION "UTSTARcom Inc"
|
|
CONTACT-INFO
|
|
"Postal: UTSTARcom Inc
|
|
Alameda, California 9xxxx
|
|
Tel: +1 510 555 1212
|
|
E-Mail: mibs@utstar.com "
|
|
DESCRIPTION
|
|
"Contains UT EPON 4000 MIB Extensions."
|
|
::= { utsGeponBBS4000 3 }
|
|
|
|
--
|
|
-- BBS 4000 only realted alarms
|
|
--
|
|
|
|
utsBBS4000FaultAlarm OBJECT IDENTIFIER ::= { utsGeponBBS4000Fault 1 }
|
|
|
|
utsChassisMgmChannelCommOk NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial bus com OK."
|
|
::= { utsBBS4000FaultAlarm 0 1 }
|
|
|
|
utsChassisMgmChannelCommAbnormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial bus com abnormal"
|
|
::= { utsBBS4000FaultAlarm 0 3 }
|
|
|
|
utsChassisInvalidCardPlugout NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmSessionId
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when the invalid card plug out, clear the alarm!"
|
|
::= { utsBBS4000FaultAlarm 0 4 }
|
|
|
|
utsChassisInvalidCardInsert NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when the card insert and detect the invalid card that system do not recognize."
|
|
::= { utsBBS4000FaultAlarm 0 6 }
|
|
|
|
-- utsDownloadMgmImgOK NOTIFICATION-TYPE
|
|
-- OBJECTS {
|
|
-- utAlarmSeqNo,
|
|
-- utAlarmOccurrenceTime,
|
|
-- utAlarmSeverity,
|
|
-- utAlarmProbableCause,
|
|
-- utAlarmType,
|
|
-- utAlarmClearType,
|
|
-- utAlarmResourceType,
|
|
-- alarmModule
|
|
--
|
|
-- }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "when download the image ok, clear the alarm!"
|
|
-- ::= { utsBBS4000FaultAlarm 0 8 }
|
|
--
|
|
-- utsDownloadMgmImgFail NOTIFICATION-TYPE
|
|
-- OBJECTS {
|
|
-- utAlarmSeqNo,
|
|
-- utAlarmOccurrenceTime,
|
|
-- utAlarmSeverity,
|
|
-- utAlarmProbableCause,
|
|
-- utAlarmType,
|
|
-- utAlarmClearType,
|
|
-- utAlarmResourceType,
|
|
-- alarmModule
|
|
-- }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "when downlaod image to the slot fail, raise the alarm"
|
|
-- ::= { utsBBS4000FaultAlarm 0 10 }
|
|
|
|
utsTemperatureNormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when temperature back to normal, clear the alarm!"
|
|
::= { utsBBS4000FaultAlarm 0 12 }
|
|
|
|
utsTemperatureTooHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when temperature too high, raise the alarm"
|
|
::= { utsBBS4000FaultAlarm 0 14 }
|
|
|
|
utsFanNormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmFanNumber,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when fan normal, clear the alarm!"
|
|
::= { utsBBS4000FaultAlarm 0 16 }
|
|
|
|
utsFanAbnormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmFanNumber,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when fam abnormal, raise the alarm"
|
|
::= { utsBBS4000FaultAlarm 0 18 }
|
|
|
|
utsSysPowerNormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmPowerSlotNumber,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when fan normal, clear the alarm!"
|
|
::= { utsBBS4000FaultAlarm 0 20 }
|
|
|
|
utsSysPowerAbnormal NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmPowerSlotNumber,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when fam abnormal, raise the alarm"
|
|
::= { utsBBS4000FaultAlarm 0 22 }
|
|
|
|
-- utsCardAbnormalRemove NOTIFICATION-TYPE
|
|
-- OBJECTS {
|
|
-- utAlarmSeqNo,
|
|
-- utAlarmOccurrenceTime,
|
|
-- utAlarmSeverity,
|
|
-- utAlarmProbableCause,
|
|
-- utAlarmType,
|
|
-- utAlarmClearType,
|
|
-- utAlarmResourceType,
|
|
-- alarmModule,
|
|
-- alarmBBS4000ModuleType
|
|
-- }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Raise when card has been detected not present without hotswap or card failure, need manual clear!"
|
|
-- ::= { utsBBS4000FaultAlarm 0 26 }
|
|
|
|
utsDownloadPonImgOK NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmSessionId
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when download the pon image ok, clear the alarm!"
|
|
::= { utsBBS4000FaultAlarm 0 28 }
|
|
|
|
utsDownloadPonImgFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"when downlaod image to the pon port fail, raise the alarm"
|
|
::= { utsBBS4000FaultAlarm 0 30 }
|
|
|
|
utsOnuUNILinkUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clear when PON shutdown or ONU shutdown or ONU link down or UNI link up."
|
|
::= { utsBBS4000FaultAlarm 0 32 }
|
|
|
|
utsOnuUNILinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmPort,
|
|
alarmLogicalPort,
|
|
alarmMacAddress,
|
|
alarmEponOnuHwType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Raise when ONU link up but UNI port link down."
|
|
::= { utsBBS4000FaultAlarm 0 34 }
|
|
|
|
utsBBS4000CardInsertAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmBBS4000ModuleType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Card Insert for bbs 4000!"
|
|
::= { utsBBS4000FaultAlarm 0 36 }
|
|
|
|
utsBBS4000CardRemoveAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utAlarmSeqNo,
|
|
utAlarmOccurrenceTime,
|
|
utAlarmSeverity,
|
|
utAlarmProbableCause,
|
|
utAlarmType,
|
|
utAlarmClearType,
|
|
utAlarmResourceType,
|
|
alarmModule,
|
|
alarmBBS4000ModuleType,
|
|
alarmSessionId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Card remove for bbs 4000"
|
|
::= { utsBBS4000FaultAlarm 0 38 }
|
|
|
|
--
|
|
-- BBS 4000 only realted event
|
|
--
|
|
|
|
utsBBS4000CardInsertEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmBBS4000ModuleType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BBS 4000 Card Insert Event!"
|
|
::= { utsBBS4000FaultAlarm 0 40 }
|
|
|
|
utsBBS4000CardRemoveEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmBBS4000ModuleType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BBS 4000 card Remove Event!"
|
|
::= { utsBBS4000FaultAlarm 0 42 }
|
|
|
|
utsCardAbnormalRemoveEvent NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
utEventSeqNo,
|
|
utEventOccurrenceTime,
|
|
alarmModule,
|
|
alarmBBS4000ModuleType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Send out when card has been detected not present without hotswap or card failure!"
|
|
::= { utsBBS4000FaultAlarm 0 45 }
|
|
|
|
|
|
END
|
|
|