Observium_CE/mibs/trendmicro/TPT-PORT-MAPPING-MIB

165 lines
5.7 KiB
Plaintext

-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
--
-- Trend Micro, Inc.
-- Copyright information is in the DESCRIPTION section of the MODULE-IDENTITY.
--
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TPT-PORT-MAPPING-MIB
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32
FROM SNMPv2-SMI
InterfaceIndex
FROM IF-MIB
tpt-tpa-objs
FROM TPT-TPAMIBS-MIB
;
tpt-port-mapping-objs MODULE-IDENTITY
LAST-UPDATED "201610031200Z" -- Oct 3, 2016
ORGANIZATION "Trend Micro, Inc."
CONTACT-INFO "www.trendmicro.com"
DESCRIPTION
"Configurable logical to physical port mapping on a device.
Copyright (C) 2016 Trend Micro Incorporated. All Rights Reserved.
Trend Micro makes no warranty of any kind with regard to this material,
including, but not limited to, the implied warranties of merchantability
and fitness for a particular purpose. Trend Micro shall not be liable for
errors contained herein or for incidental or consequential damages in
connection with the furnishing, performance, or use of this material. This
document contains proprietary information, which is protected by copyright. No
part of this document may be photocopied, reproduced, or translated into
another language without the prior written consent of Trend Micro. The
information is provided 'as is' without warranty of any kind and is subject to
change without notice. The only warranties for Trend Micro products and
services are set forth in the express warranty statements accompanying such
products and services. Nothing herein should be construed as constituting an
additional warranty. Trend Micro shall not be liable for technical or editorial
errors or omissions contained herein. TippingPoint(R), the TippingPoint logo, and
Digital Vaccine(R) are registered trademarks of Trend Micro. All other company
and product names may be trademarks of their respective holders. All rights
reserved. This document contains confidential information, trade secrets or
both, which are the property of Trend Micro. No part of this documentation may
be reproduced in any form or by any means or used to make any derivative work
(such as translation, transformation, or adaptation) without written permission
from Trend Micro or one of its subsidiaries. All other company and product
names may be trademarks of their respective holders.
"
REVISION "201610031200Z" -- Oct 3, 2016
DESCRIPTION "Fixed portMappingPhysicalVlanId to use Integer32 instead of INTEGER."
REVISION "201605251854Z" -- May 25, 2016
DESCRIPTION "Updated copyright information. Minor MIB syntax fixes."
::= { tpt-tpa-objs 16 }
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
--
-- Table of port mapping settings on the device
--
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
portMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of logical slots/ports on the device and their mapping to the physical ports."
::= { tpt-port-mapping-objs 1 }
portMappingEntry OBJECT-TYPE
SYNTAX PortMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the slot/port table.
Rows cannot be created or deleted."
INDEX { portMappingLogicalSlot, portMappingLogicalPort }
::= { portMappingTable 1 }
PortMappingEntry ::= SEQUENCE {
portMappingLogicalSlot Unsigned32,
portMappingLogicalPort Unsigned32,
portMappingLogicalIfIndex InterfaceIndex,
portMappingPhysicalSlot Unsigned32,
portMappingPhysicalPort Unsigned32,
portMappingPhysicalIfIndex InterfaceIndex,
portMappingSegmentName OCTET STRING (SIZE (0..128)),
portMappingPhysicalVlanId Integer32 (0..4094)
}
portMappingLogicalSlot OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number for this logical port."
::= { portMappingEntry 1 }
portMappingLogicalPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port number for this logical port."
::= { portMappingEntry 2 }
portMappingLogicalIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entry in the IF-MIB interface table that corresponds to this logical port."
::= { portMappingEntry 3 }
portMappingPhysicalSlot OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number for the mapped physical port."
::= { portMappingEntry 4 }
portMappingPhysicalPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port number for the mapped physical port."
::= { portMappingEntry 5 }
portMappingPhysicalIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entry in the IF-MIB interface table that corresponds to the mapped physical port."
::= { portMappingEntry 6 }
portMappingSegmentName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The name of the segment pertaining to this logical port."
::= { portMappingEntry 7 }
portMappingPhysicalVlanId OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN ID used on the physical port. 0 indicates the traffic is untagged or not applicable for this port."
::= { portMappingEntry 8 }
END