Observium_CE/mibs/rfc/IEEE8021-CN-MIB

2119 lines
70 KiB
Plaintext

IEEE8021-CN-MIB
DEFINITIONS ::= BEGIN
-- ******************************************************************
-- IEEE Std 802.1Q(TM) Congestion Management MIB
-- ******************************************************************
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI -- [RFC2578]
Counter32
FROM SNMPv2-SMI -- [RFC2578]
Counter64
FROM SNMPv2-SMI -- [RFC2578]
Unsigned32
FROM SNMPv2-SMI -- [RFC2578]
TEXTUAL-CONVENTION,
TimeInterval
FROM SNMPv2-TC -- [RFC2579]
RowStatus
FROM SNMPv2-TC -- [RFC2579]
TruthValue
FROM SNMPv2-TC -- [RFC2579]
MacAddress
FROM SNMPv2-TC -- [RFC2579]
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF -- [RFC2580]
InterfaceIndex
FROM IF-MIB -- [RFC2863]
ifGeneralInformationGroup
FROM IF-MIB -- [RFC2863]
ieee802dot1mibs
FROM IEEE8021-TC-MIB
IEEE8021PriorityValue
FROM IEEE8021-TC-MIB
IEEE8021PbbComponentIdentifier
FROM IEEE8021-TC-MIB -- [IEEE Std 802.1ap]
LldpV2DestAddressTableIndex
FROM LLDP-V2-TC-MIB
systemGroup
FROM SNMPv2-MIB -- [RFC3418]
;
ieee8021CnMib
MODULE-IDENTITY
LAST-UPDATED "201806280000Z" -- June 28, 2018
ORGANIZATION "IEEE 802.1 Working Group"
CONTACT-INFO
"WG-URL: http://www.ieee802.org/1/
WG-EMail: stds-802-1-L@ieee.org
Contact: IEEE 802.1 Working Group Chair
Postal: C/O IEEE 802.1 Working Group
IEEE Standards Association
445 Hoes Lane
Piscataway
NJ 08854
USA
E-mail: STDS-802-1-L@IEEE.ORG
"
DESCRIPTION
"Congestion notification module.
Unless otherwise indicated, the references in this MIB
module are to IEEE Std 802.1Q.
Copyright (C) IEEE (2018).
This version of this MIB module is part of IEEE Std 802.1Q;
see the draft itself for full legal notices."
REVISION "201806280000Z" -- June 28, 2018
DESCRIPTION
"Published as part of IEEE Std 802.1Q-2018.
Cross references updated and corrected."
REVISION "201412150000Z" -- December 15, 2014
DESCRIPTION
"Published as part of IEEE Std 802.1Q 2014 revision.
Cross references updated and corrected.
Imports tidied up to remove orphaned commas."
REVISION "201102270000Z" -- February 27, 2011
DESCRIPTION
"Minor edits to contact information etc. as part of
2011 revision of IEEE Std 802.1Q."
REVISION "200912180000Z" -- 12/18/2009 00:00GMT
DESCRIPTION
"Included in IEEE 802.1Qau-2010
Copyright (C) IEEE."
::= { ieee802dot1mibs 18 }
ieee8021CnMIBObjects
OBJECT IDENTIFIER ::= { ieee8021CnMib 1 }
ieee8021CnConformance
OBJECT IDENTIFIER ::= { ieee8021CnMib 2 }
-- ******************************************************************
-- Textual conventions
-- ******************************************************************
Ieee8021CnControlChoice
::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This controls what other object selects the CND defense mode and
the Congestion Notification Priority Value (CNPV) alternate
priority for a CNPV in an end station or Bridge component, or
for a CNPV on a particular Port in an end station or Bridge
component. It can take the following values:
cpcAdmin(1) The CND defense mode and alternate priority are
controlled by the administrative variables in the
same table entry as this object.
cpcAuto(2) This Port or all Ports' CND defense modes are
controlled automatically, as indicated by
ieee8021CnPortPriAutoDefenseMode, and the
alternate priority by ieee8021CnComPriAutoAltPri.
cpcComp(3) This CND defense mode and alternate priority are
both controlled by ieee8021CnPortPriTable.
"
REFERENCE
"32.3.1, 32.4.1, Table 32-2"
SYNTAX INTEGER {
cpcAdmin (1),
cpcAuto (2),
cpcComp (3)
}
Ieee8021CnDefenseMode
::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"For a given Congestion Notification Priority Value (CNPV), a
port can operate in one of four CND defense modes. The CND
defense mode determines whether congestion notification is
enabled or not, and if enabled, whether the port translates the
CNPV to a non-CNPV value on input, and whether the port removes
CN-TAGs on output.
cptDisabled(1) The congestion notification capability is
administratively disabled for this priority
value and port. This priority is not a CNPV.
The priority regeneration table controls the
remapping of input frames on this port for
this priority. CN-TAGs are neither added by
an end station nor stripped by a Bridge.
cptInterior(2) On this port and for this CNPV, the priority
parameters of input frames are not remapped,
regardless of the priority regeneration
table. CN-TAGs are not added by an end
station, and are removed from frames before
being output by a Bridge.
cptInteriorReady(3) On this port and for this CNPV, the priority
parameters of input frames are not remapped,
regardless of the priority regeneration
table. CN-TAGs can be added by an end
station, and are not removed from frames by
a Bridge.
cptEdge(4) On this port and for this CNPV, the priority
parameters of input frames are remapped to
an alternate (non-CNPV) value, regardless of
the priority regeneration table. CN-TAGs are
not added by an end station, and are removed
from frames before being output by a Bridge.
This mode is optional for an end station.
"
REFERENCE
"32.1.1, 32.3.4, 32.4.2, 32.4.3, Table 32-2"
SYNTAX INTEGER {
cptDisabled (1),
cptInterior (2),
cptInteriorReady (3),
cptEdge (4)
}
Ieee8021CnLldpChoice
::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies how to determine what index value is to be used as
the index to lldpDestAddressTable, the table of destination MAC
addresses, for both the destination addresses on transmitted
LLDPDUs and on received LLDPDUs, found in the LLDP-MIB, either:
cnlNone(1) No LLDP Congestion Notification TLV is to
carry Per-priority CNPV indicators or
Per-priority Ready indicators on this Port
for this priority (or all Ports and all
priorities, as appropriate to the managed
object).
cnlAdmin(2) The administrative LLDP instance selector
in the same table entry as this object
governs which LLDP instance will carry the
Per-priority CNPV indicators and
Per-priority Ready indicators for this
priority in its Congestion Notification TLV
on this Port (or all Ports and all
priorities, as appropriate to the managed
object).
cnlComponent(3) ieee8021CnComPriLldpInstanceSelector governs
LLDP instance selection for this Port and
priority.
"
REFERENCE
"32.3.6, 32.4.4, Table 32-1"
SYNTAX INTEGER {
cnlNone (1),
cnlAdmin (2),
cnlComponent (3)
}
-- ******************************************************************
-- The Global Table. This group will contain the MIB objects that
-- apply to the whole Bridge component or end station.
-- ******************************************************************
ieee8021CnGlobalTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnGlobalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the global variables for each component of
a Bridge or for an end station. A value of 1 is used in a
Bridge or end station that does not have multiple components.
The contents of this table SHALL be maintained across a restart
of the system.
"
REFERENCE
"12.21.1"
::= { ieee8021CnMIBObjects 1 }
ieee8021CnGlobalEntry
OBJECT-TYPE
SYNTAX Ieee8021CnGlobalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of objects pertaining to a whole Bridge component or
end station.
"
INDEX { ieee8021CnGlobalComponentId }
::= { ieee8021CnGlobalTable 1 }
Ieee8021CnGlobalEntry
::= SEQUENCE {
ieee8021CnGlobalComponentId IEEE8021PbbComponentIdentifier,
ieee8021CnGlobalMasterEnable TruthValue,
ieee8021CnGlobalCnmTransmitPriority IEEE8021PriorityValue,
ieee8021CnGlobalDiscardedFrames Counter64
}
ieee8021CnGlobalComponentId
OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge component within the system to which the information
in this ieee8021CnGlobalEntry applies. If the system is not
a Bridge, or if only one component is present in the Bridge,
then this variable (index) MUST be equal to 1.
"
::= { ieee8021CnGlobalEntry 1 }
ieee8021CnGlobalMasterEnable
OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The state of the congestion notification feature on this Bridge
component or system. If true, Congestion notification is
enabled, and if false, congestion notification is disabled.
"
REFERENCE
"32.2.1"
::= { ieee8021CnGlobalEntry 2 }
ieee8021CnGlobalCnmTransmitPriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The priority to use for all Congestion Notification Messages
transmitted by this Bridge component or end station.
"
REFERENCE
"32.2.2"
::= { ieee8021CnGlobalEntry 3 }
ieee8021CnGlobalDiscardedFrames
OBJECT-TYPE
SYNTAX Counter64
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames discarded from full CP queues, in spite
of the efforts of congestion notification to avoid discards.
This object is incremented whenever any of the
ieee8021CnCpDiscardedFrames objects on any Port or priority in
this same component are incremented.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime object of the associated
interface (if any).
"
REFERENCE
"32.2.3"
::= { ieee8021CnGlobalEntry 4 }
-- ******************************************************************
-- The CCF Errored Port Table. One per Bridge component or end station.
-- Scanning this table reveals which Interfaces at which priorities
-- have an Alternate Priority value that is a
-- Congestion Notification Priority Value.
-- ******************************************************************
ieee8021CnErroredPortTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnErroredPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one Errored Port Table per Bridge component or end
station. It permits the retrieval of information about which
interfaces have congestion notification configuration errors,
namely, those specifying an alternate priority that is a CNPV.
"
REFERENCE
"32.2.4"
::= { ieee8021CnMIBObjects 2 }
ieee8021CnErroredPortEntry
OBJECT-TYPE
SYNTAX Ieee8021CnErroredPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interfaces whose ieee8021CnComPriAlternatePriority
and/or ieee8021CnPortPriAlternatePriority specify a priority
value that is a Congestion Notification Priority Value.
"
REFERENCE
"32.2.4"
INDEX { ieee8021CnEpComponentId,
ieee8021CnEpPriority,
ieee8021CnEpIfIndex}
::= { ieee8021CnErroredPortTable 1 }
Ieee8021CnErroredPortEntry
::= SEQUENCE {
ieee8021CnEpComponentId IEEE8021PbbComponentIdentifier,
ieee8021CnEpPriority IEEE8021PriorityValue,
ieee8021CnEpIfIndex InterfaceIndex
}
ieee8021CnEpComponentId
OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge component within the system to which the information
in this ieee8021CnErroredPortEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
REFERENCE
"32.2.4"
::= { ieee8021CnErroredPortEntry 1 }
ieee8021CnEpPriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The priority value whose alternate priority is misconfigured.
"
REFERENCE
"32.2.4"
::= { ieee8021CnErroredPortEntry 2 }
ieee8021CnEpIfIndex
OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the Bridge Port or aggregated port
on which the congestion notification alternate priority is
misconfigured.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable so that it references the row
in the ifXTable with the same value of ifAlias that it
referenced before the system restart. If no such row exists,
then the system SHALL delete this row in the
ieee8021CnErroredPortTable.
"
REFERENCE
"32.2.4"
::= { ieee8021CnErroredPortEntry 3 }
-- ******************************************************************
-- The CCF Per-component per-priority table. One table per Bridge
-- component or end station, one entry per
-- Congestion Notification Priority Value
-- ******************************************************************
ieee8021CnCompntPriTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnCompntPriEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row in this table supplies default values for one
Congestion Notification Priority Value for a whole Bridge
component or end station.
Creating a row in this table makes the priority value of
ieee8021CnComPriPriority a
Congestion Notification Priority Value.
Deleting a row in this table makes the value in the deleted
ieee8021CnComPriPriority no longer a
Congestion Notification Priority Value.
A system SHALL NOT allow eight rows in this table
to be created with the same value of
ieee8021CnComPriComponentId; see the description of
ieee8021CnComPriRowStatus.
The contents of this table SHALL be maintained across a restart
of the system.
"
REFERENCE
"12.21.2, 12.21.2.1, 12.21.2.2"
::= { ieee8021CnMIBObjects 3 }
ieee8021CnCompntPriEntry
OBJECT-TYPE
SYNTAX Ieee8021CnCompntPriEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"One entry per Congestion Notification Priority Value per
Bridge component or end station.
"
REFERENCE
"12.21.2, 12.21.2.1, 12.21.2.2"
INDEX { ieee8021CnComPriComponentId,
ieee8021CnComPriPriority }
::= { ieee8021CnCompntPriTable 1 }
Ieee8021CnCompntPriEntry
::= SEQUENCE {
ieee8021CnComPriComponentId IEEE8021PbbComponentIdentifier,
ieee8021CnComPriPriority IEEE8021PriorityValue,
ieee8021CnComPriDefModeChoice Ieee8021CnControlChoice,
ieee8021CnComPriAlternatePriority IEEE8021PriorityValue,
ieee8021CnComPriAutoAltPri IEEE8021PriorityValue,
ieee8021CnComPriAdminDefenseMode Ieee8021CnDefenseMode,
ieee8021CnComPriCreation INTEGER,
ieee8021CnComPriLldpInstanceChoice Ieee8021CnLldpChoice,
ieee8021CnComPriLldpInstanceSelector LldpV2DestAddressTableIndex,
ieee8021CnComPriRowStatus RowStatus
}
ieee8021CnComPriComponentId
OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge component within the system to which the information
in this ieee8021CnCompntPriEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
REFERENCE
"12.21.2, 12.21.2.1, 12.21.2.2"
::= { ieee8021CnCompntPriEntry 1 }
ieee8021CnComPriPriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Congestion Notification Priority Value for which this
row supplies default values.
"
REFERENCE
"802.1Qau clauses 12.21.2"
::= { ieee8021CnCompntPriEntry 2 }
ieee8021CnComPriDefModeChoice
OBJECT-TYPE
SYNTAX Ieee8021CnControlChoice {
cpcAdmin (1),
cpcAuto (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies how the default CND defense mode and alternate
priority for this Congestion Notification Priority Value on all
ports on this Bridge component or end station are to be chosen,
either:
cpcAdmin(1) Default CND defense mode is chosen by
ieee8021CnComPriAdminDefenseMode, and alternate
priority by ieee8021CnComPriAlternatePriority.
cpcAuto(2) Default CND defense mode is chosen by
ieee8021CnPortPriAutoDefenseMode, and alternate
priority by ieee8021CnComPriAutoAltPri.
This variable can be overridden by
ieee8021CnPortPriDefModeChoice.
"
REFERENCE
"32.1.3, 32.3.1"
DEFVAL { cpcAuto }
::= { ieee8021CnCompntPriEntry 3 }
ieee8021CnComPriAlternatePriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Congestion Notification Priority Value to which an
incoming frame is to be mapped, in spite of what the
Priority Regereration Table says, if 1) Congestion
Notification is enabled and 2) the CND defense mode of the
port is cptEdge.
Deleting a row in this table does not alter the value of any
other row's ieee8021CnComPriAlternatePriority.
"
REFERENCE
"802.1Qau clauses 32.3.2"
DEFVAL { 0 }
::= { ieee8021CnCompntPriEntry 4 }
ieee8021CnComPriAutoAltPri
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Congestion Notification Priority Value to which an
incoming frame can be mapped, in spite of what the
Priority Regereration Table says, if 1) Congestion
Notification is enabled, 2) the CND defense mode of the
port is cptEdge, and 3) ieee8021CnComPriDefModeChoice
contains the value cpcAuto (2).
The value of this object is the next lower priority value
than this row's ieee8021CnComPriPriority that is not a CNPV,
or the next higher non-CNPV, if all lower values are CNPVs.
The value of this object, and any consequent priority
regeneration, is automatically updated by the managed system
whenever a row in the ieee8021CnCompntPriTable is created or
deleted. The value of this object is not dependent upon
whether congestion notification is enabled or disabled for any
priority or for the whole Bridge component or end station; it
depends only upon whether the ieee8021CnCompntPriTable row
exists.
"
REFERENCE
"802.1Qau clauses 32.3.3"
::= { ieee8021CnCompntPriEntry 5 }
ieee8021CnComPriAdminDefenseMode
OBJECT-TYPE
SYNTAX Ieee8021CnDefenseMode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The default CND defense mode for this
Congestion Notification Priority Value on all ports on this
Bridge component or end station.
This variable can be overridden by
ieee8021CnPortPriAdminDefenseMode.
"
REFERENCE
"32.1.3, 32.3.4"
DEFVAL { cptInterior }
::= { ieee8021CnCompntPriEntry 6 }
ieee8021CnComPriCreation
OBJECT-TYPE
SYNTAX INTEGER {
cncpAutoEnable (1),
cncpAutoDisable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The default value for ieee8021CnComPriDefModeChoice for
newly-created entries in the ieee8021CnPortPriTable:
cncpAutoEnable (1) Newly-created
ieee8021CnPortPriDefModeChoice
objects take the value cpcComp (3).
cncpAutoDisable(2) Newly-created
ieee8021CnPortPriDefModeChoice
objects take the value cpcAdmin (1).
"
REFERENCE
"32.3.5"
DEFVAL { cncpAutoEnable }
::= { ieee8021CnCompntPriEntry 7 }
ieee8021CnComPriLldpInstanceChoice
OBJECT-TYPE
SYNTAX Ieee8021CnLldpChoice {
cnlNone (1),
cnlAdmin (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies whether or not the default value for all Ports is to
send and receive the Congestion Notification TLV in LLDPDUs,
either:
cnlNone(1) Do not send Congestion Notification TLVs, and
ignore them on receipt.
cnlAdmin(2) Use the LLDP instance selected by
ieee8021CnComPriLldpInstanceSelector to send and
receive the Congestion Notification TLV.
This object can be overridden by
ieee8021CnPortPriLldpInstanceChoice.
"
REFERENCE
"32.1.3, 32.3.6"
DEFVAL { cnlAdmin }
::= { ieee8021CnCompntPriEntry 8 }
ieee8021CnComPriLldpInstanceSelector
OBJECT-TYPE
SYNTAX LldpV2DestAddressTableIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies a default value for which LLDP instance is to be
used to provide the information for automatic configuration
of ports' CND defense modes (ieee8021CnPortPriAutoDefenseMode).
This object is ignored by the managed system if
ieee8021CnComPriLldpInstanceChoice contains the value cnlNone
(1).
This object can be overridden by
ieee8021CnPortPriLldpInstanceChoice and
ieee8021CnPortPriLldpInstanceChoice.
"
REFERENCE
"32.1.3, 32.3.7"
DEFVAL { 1 }
::= { ieee8021CnCompntPriEntry 9 }
ieee8021CnComPriRowStatus
OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of an entry, and is used
to create/delete entries.
A system SHALL NOT permit eight ieee8021CnComPriRowStatus
objects, all with the same value of ieee8021CnComPriComponentId,
to have the value active(1). An attempt to create or activate
a row when there are already seven active rows SHALL result in
that eighth row's ieee8021CnComPriRowStatus having the value
notReady(3), and the return of an inconsistentValue error.
"
REFERENCE
"30.4"
::= { ieee8021CnCompntPriEntry 10 }
-- ******************************************************************
-- The CCF Per-component per-interface per-priority table. One table
-- per end station or Bridge component. One entry per interface per
-- priority value, but only for priority values that are
-- Congestion Notification Priority Values (CNPVs). Controls
-- a CNPV on a specific port when the default values in
-- ieee8021CnCompntPriTable need to be overridden.
-- ******************************************************************
ieee8021CnPortPriTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnPortPriEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row in this table supplies values for one port's
Congestion Notification Priority Value (CNPV).
Creating an entry in ieee8021CnCompntPriTable creates this
entry, with the default values, on all ports in the Bridge
component or end station. Deleting an entry in
ieee8021CnCompntPriTable deletes this ieee8021CnCompntPriEntry
on all ports in the Bridge component or end station.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnPortPriIfIndex.
"
REFERENCE
"12.21.3"
::= { ieee8021CnMIBObjects 4 }
ieee8021CnPortPriEntry
OBJECT-TYPE
SYNTAX Ieee8021CnPortPriEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"One entry per port per Congestion Notification Priority Value
per Bridge component or end station.
"
REFERENCE
"12.21.3"
INDEX { ieee8021CnPortPriComponentId,
ieee8021CnPortPriority,
ieee8021CnPortPriIfIndex }
::= { ieee8021CnPortPriTable 1 }
Ieee8021CnPortPriEntry
::= SEQUENCE {
ieee8021CnPortPriComponentId IEEE8021PbbComponentIdentifier,
ieee8021CnPortPriority IEEE8021PriorityValue,
ieee8021CnPortPriIfIndex InterfaceIndex,
ieee8021CnPortPriDefModeChoice Ieee8021CnControlChoice,
ieee8021CnPortPriAdminDefenseMode Ieee8021CnDefenseMode,
ieee8021CnPortPriAutoDefenseMode Ieee8021CnDefenseMode,
ieee8021CnPortPriLldpInstanceChoice Ieee8021CnLldpChoice,
ieee8021CnPortPriLldpInstanceSelector
LldpV2DestAddressTableIndex,
ieee8021CnPortPriAlternatePriority IEEE8021PriorityValue
}
ieee8021CnPortPriComponentId
OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge component within the system to which the information
in this ieee8021CnPortPriEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
REFERENCE
"12.21.3"
::= { ieee8021CnPortPriEntry 1 }
ieee8021CnPortPriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Congestion Notification Priority Value for which
this row supplies default values.
"
REFERENCE
"802.1Qau clauses 12.21.3"
::= { ieee8021CnPortPriEntry 2 }
ieee8021CnPortPriIfIndex
OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the port or aggregated port
to which the entry applies.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this object, and rearrange the order of the
ieee8021CnPortPriTable, so that the value in
ieee8021CnPortPriIfIndex references the row in the ifXTable
with the same value for ifAlias that it referenced before the
system restart. If no such entry exists in the ifXTable, then
the system SHALL delete the row in the ieee8021CnPortPriTable.
"
REFERENCE
"12.21.3"
::= { ieee8021CnPortPriEntry 3 }
ieee8021CnPortPriDefModeChoice
OBJECT-TYPE
SYNTAX Ieee8021CnControlChoice
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines how the CND defense mode and alternate
priority value of this port for this CNPV is to be selected,
either:
cpcAdmin(1) CND defense mode is controlled by
ieee8021CnPortPriAdminDefenseMode, and alternate
priority by ieee8021CnPortPriAlternatePriority.
cpcAuto(2) CND defense mode is controlled by
ieee8021CnPortPriAutoDefenseMode and alternate
priority by ieee8021CnComPriAlternatePriority.
cpcComp(3) CND defense mode and alternate priority are
controlled by
ieee8021CnComPriDefModeChoice.
This variable can override ieee8021CnComPriDefModeChoice.
"
REFERENCE
"IEEE 32.1.3, 32.4.1"
DEFVAL { cpcComp }
::= { ieee8021CnPortPriEntry 4 }
ieee8021CnPortPriAdminDefenseMode
OBJECT-TYPE
SYNTAX Ieee8021CnDefenseMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the operator's choice for the CND defense
mode in which this port is to operate for this CNPV whenever
ieee8021CnPortPriDefModeChoice has the value cpcAdmin(1).
This variable can override ieee8021CnComPriDefModeChoice.
"
REFERENCE
"IEEE 32.1.3, 32.4.1"
DEFVAL { cptDisabled }
::= { ieee8021CnPortPriEntry 5 }
ieee8021CnPortPriAutoDefenseMode
OBJECT-TYPE
SYNTAX Ieee8021CnDefenseMode {
cptInterior (2),
cptInteriorReady (3),
cptEdge (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates in which the CND defense mode this port
would operate for this CNPV as determined by the LLDP
Congestion Notification TLV.
"
REFERENCE
"IEEE 32.4.3"
::= { ieee8021CnPortPriEntry 6 }
ieee8021CnPortPriLldpInstanceChoice
OBJECT-TYPE
SYNTAX Ieee8021CnLldpChoice
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies how to determine the LLDP instance to be used for the
Congestion Notification TLV, either:
cnlNone(1) No LLDP Congestion Notification TLV is to
carry Per-priority CNPV indicators or
Per-priority Ready indicators on this Port
for this priority.
cnlAdmin(2) ieee8021CnPortPriLldpInstanceSelector
governs which LLDP instance is to carry
Per-priority CNPV indicators and
Per-priority Ready indicators for this
priority in its Congestion Notification TLV
on this Port
cnlComponent(3) ieee8021CnComPriLldpInstanceChoice
governs LLDP instance selection for this
Port and priority.
This object can override ieee8021CnComPriLldpInstanceChoice.
"
REFERENCE
"32.1.3, 32.4.4"
DEFVAL { cnlComponent }
::= { ieee8021CnPortPriEntry 7 }
ieee8021CnPortPriLldpInstanceSelector
OBJECT-TYPE
SYNTAX LldpV2DestAddressTableIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines which LLDP instance selector, if any,
is used for automatic determination of the CND defense mode for
this port and CNPV.
This object can override ieee8021CnComPriLldpInstanceSelector.
"
REFERENCE
"32.1.3, 32.4.5"
DEFVAL { 3 }
::= { ieee8021CnPortPriEntry 8 }
ieee8021CnPortPriAlternatePriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Congestion Notification Priority Value to which an
incoming frame is to be mapped, in spite of what the
Priority Regereration Table says, if 1) Congestion
Notification is enabled and 2) the port is acting in the
cptEdge (4) CND defense mode.
This object is ignored unless ieee8021CnPortPriDefModeChoice
contains the value cpcAdmin (1).
"
REFERENCE
"32.4.6"
DEFVAL { 0 }
::= { ieee8021CnPortPriEntry 9 }
-- ******************************************************************
-- The CCF per-CP table. One table per end station or Bridge component.
-- One entry per Congestion Point. An entry in this table controls one
-- Congestion Point (CP).
-- ******************************************************************
ieee8021CnCpTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnCpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row in this table supplies values for one
Congestion Point (CP).
This table is indexed by component, port (interface), and
an arbitrary CP index. This arbitrary CP index is not
necessarily the Congestion Point Identifier (CPID) carried in
Congestion Notification Messages (CNMs).
Creating an entry in ieee8021CnCompntPriTable can create an
entry in this table, with the default values, on all ports in
the Bridge component or end station. Because more than one
Congestion Notification Priority Value (CNPV) can flow
through a single CP, the creation of an entry in
ieee8021CnCompntPriTable does not necessarily create a new
entry in this table. An end station can have more than one
CP for the same CNPV, so creating an entry in
ieee8021CnCompntPriTable can create multiple entries in this
table.
Because each port in a Bridge component or end station can have
a different relationship between CNPVs and CPs, the entries
created or deleted on each port can be different.
Deleting the last entry in ieee8021CnCompntPriTable for a
CNPV passing through the CP controlled by this entry deletes
the entry on some or all of the ports in the Bridge component
or end station.
Because each port in a Bridge component or end station can have
a different relationship between CNPVs and CPs, the entries
created or deleted on each port can be different.
The relationship between ieee8021CnCpIndex
values and CPs is an implementation dependent matter.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnCpIfIndex.
"
REFERENCE
"12.21.4"
::= { ieee8021CnMIBObjects 5 }
ieee8021CnCpEntry
OBJECT-TYPE
SYNTAX Ieee8021CnCpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Congestion Point table controls a single
Congestion Point on a port in a Bridge component or end station.
"
REFERENCE
"12.21.4"
INDEX { ieee8021CnCpComponentId,
ieee8021CnCpIfIndex,
ieee8021CnCpIndex }
::= { ieee8021CnCpTable 1 }
Ieee8021CnCpEntry
::= SEQUENCE {
ieee8021CnCpComponentId IEEE8021PbbComponentIdentifier,
ieee8021CnCpIfIndex InterfaceIndex,
ieee8021CnCpIndex Unsigned32,
ieee8021CnCpPriority IEEE8021PriorityValue,
ieee8021CnCpMacAddress MacAddress,
ieee8021CnCpIdentifier OCTET STRING,
ieee8021CnCpQueueSizeSetPoint Unsigned32,
ieee8021CnCpFeedbackWeight Integer32,
ieee8021CnCpMinSampleBase Unsigned32,
ieee8021CnCpDiscardedFrames Counter64,
ieee8021CnCpTransmittedFrames Counter64,
ieee8021CnCpTransmittedCnms Counter64,
ieee8021CnCpMinHeaderOctets Unsigned32
}
ieee8021CnCpComponentId
OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge component within the system to which the information
in this ieee8021CnCpEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
REFERENCE
"12.21.4"
::= { ieee8021CnCpEntry 1 }
ieee8021CnCpIfIndex
OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the port or aggregated port
to which the entry applies.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this object, and rearrange the order of the
ieee8021CnCpTable, so that the value in ieee8021CnCpIfIndex
references the row in the ifXTable with the same value for
ifAlias that it referenced before the system restart. If no
such entry exists in the ifXTable, then the system SHALL delete
the row in the ieee8021CnCpTable.
"
REFERENCE
"12.21.4"
::= { ieee8021CnCpEntry 2 }
ieee8021CnCpIndex
OBJECT-TYPE
SYNTAX Unsigned32 (1..4096)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an arbitrary integer indexing the entries in
this table among the entries for the same component and
interface. In a system that supports no more than one
Congestion Point per priority per interface, ieee8021CnCpIndex
SHALL be equal to the lowest numerical
Congestion Notification Priority Value served by this
Congestion Point. Otherwise, it SHOULD be a small integer
value.
"
REFERENCE
"12.21.4"
::= { ieee8021CnCpEntry 3 }
ieee8021CnCpPriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the lowest numerical
Congestion Notification Priority Value that this entry's
Congestion Point serves.
"
REFERENCE
"12.21.4"
::= { ieee8021CnCpEntry 4 }
ieee8021CnCpMacAddress
OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the MAC address used as the source
address in Congestion Notification Message transmitted
by this Congestion Point.
"
REFERENCE
"32.8.1"
::= { ieee8021CnCpEntry 5 }
ieee8021CnCpIdentifier
OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Congestion Point Identifier (CPID)
transmitted in Congestion Notification Message by this
Congestion Point.
It is not specified whether the CPID reported in a CNM by a CP
that serves multiple CNPVs does or does not have the same value
for its different CNPVs.
"
REFERENCE
"32.8.2"
::= { ieee8021CnCpEntry 6 }
ieee8021CnCpQueueSizeSetPoint
OBJECT-TYPE
SYNTAX Unsigned32 (100..4294967295)
UNITS "octets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the set point for the queue managed by this
Congestion Point (CP). Congestion Notification Messages are
transmitted to the sources of frames queued in this CP's
queue in order to keep the total number of octets stored in
the queue at this set point.
"
REFERENCE
"30.2, 32.8.3"
DEFVAL { 26000 }
::= { ieee8021CnCpEntry 7 }
ieee8021CnCpFeedbackWeight
OBJECT-TYPE
SYNTAX Integer32 (-10..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the weight (cpW) change in queue length
in the calculation of cpFb when the Congestion Point is
generating a Congestion Notification Message.
The weight cpW is equal to two to the power of this object.
Thus, if this object contains a -1, cpW = 1/2.
"
REFERENCE
"32.8.6"
DEFVAL { 1 }
::= { ieee8021CnCpEntry 8 }
ieee8021CnCpMinSampleBase
OBJECT-TYPE
SYNTAX Unsigned32 (10000..4294967295)
UNITS "octets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the minimum number of octets to
enqueue in the Congestion Point's queue between transmissions
of Congestion Notification Messages.
"
REFERENCE
"32.8.11"
DEFVAL { 150000 }
::= { ieee8021CnCpEntry 9 }
ieee8021CnCpDiscardedFrames
OBJECT-TYPE
SYNTAX Counter64
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data frames discarded by the queue controlled
by this Congestion Point due to queue congestion.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime object of the associated
interface (if any).
"
REFERENCE
"32.8.12"
::= { ieee8021CnCpEntry 10 }
ieee8021CnCpTransmittedFrames
OBJECT-TYPE
SYNTAX Counter64
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data frames passed on to the queue controlled by
this Congestion Point that were not discarded due to queue
congestion.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime object of the associated
interface (if any).
"
REFERENCE
"32.8.13"
::= { ieee8021CnCpEntry 11 }
ieee8021CnCpTransmittedCnms
OBJECT-TYPE
SYNTAX Counter64
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Congestion Notification Message transmitted
by this Congestion Point.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime object of the associated
interface (if any).
"
REFERENCE
"32.8.14"
::= { ieee8021CnCpEntry 12 }
ieee8021CnCpMinHeaderOctets
OBJECT-TYPE
SYNTAX Unsigned32 (0..64)
UNITS "octets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the minimum number of octets to be returned in a
Congestion Notification Message from the mac_service_data_unit
of the data frame that triggered transmission of the CNM. If
the mac_service_data_unit has fewer octets than the value of
this object, then all of the mac_service_data_unit is returned
in the CNM.
"
REFERENCE
"32.8.15, 32.9.4 k)"
DEFVAL { 0 }
::= { ieee8021CnCpEntry 13 }
-- ******************************************************************
-- The CPID to {Interface, CP index} table. One table per system.
-- One entry per CPID.
-- ******************************************************************
ieee8021CnCpidToInterfaceTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnCpidToInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows the network manager to obtain the
interface index and CP index needed to access an entry in
the ieee8021CnCpTable, given a Congestion Point Identifier
(CPID) received a Congestion Notification Messages (CNMs).
Upon a restart of the system, the system SHALL, if necessary,
update this table to be consistent with the ieee8021CnCpTable.
"
REFERENCE
"17.2.13, 12.21.4, 32.8.2"
::= { ieee8021CnMIBObjects 6 }
ieee8021CnCpidToInterfaceEntry
OBJECT-TYPE
SYNTAX Ieee8021CnCpidToInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ieee8021CnCpidToInterfaceTable. Translates
a Congestion Point Identifier to a component identifier,
interface index, and CP index
"
REFERENCE
"17.2.13"
INDEX { ieee8021CnCpidToIfCpid }
::= { ieee8021CnCpidToInterfaceTable 1 }
Ieee8021CnCpidToInterfaceEntry
::= SEQUENCE {
ieee8021CnCpidToIfCpid OCTET STRING,
ieee8021CnCpidToIfComponentId IEEE8021PbbComponentIdentifier,
ieee8021CnCpidToIfIfIndex InterfaceIndex,
ieee8021CnCpidToIfCpIndex Unsigned32
}
ieee8021CnCpidToIfCpid
OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is the Congestion Point Identifier (CPID)
transmitted in Congestion Notification Message by a
Congestion Point residing in this Bridge component or
end station.
"
REFERENCE
"17.2.13, 32.8.2"
::= { ieee8021CnCpidToInterfaceEntry 1 }
ieee8021CnCpidToIfComponentId
OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Bridge component within the system to which the information
in this ieee8021CnCpidToInterfaceEntry applies. If the system
is not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
REFERENCE
"17.2.13"
::= { ieee8021CnCpidToInterfaceEntry 2 }
ieee8021CnCpidToIfIfIndex
OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the interface on which the selected
Congestion Point resides. This value can be used, along
with ieee8021CnCpidToIfCpIndex, to find the Congestion Point
in the ieee8021CnCpTable.
"
REFERENCE
"17.2.13"
::= { ieee8021CnCpidToInterfaceEntry 3 }
ieee8021CnCpidToIfCpIndex
OBJECT-TYPE
SYNTAX Unsigned32 (1..4096)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Congestion Point's index on the
interface on which the selected Congestion Point resides.
This value can be used, along with ieee8021CnCpidToIfIfIndex,
to find the Congestion Point in the ieee8021CnCpTable.
"
REFERENCE
"17.2.13"
::= { ieee8021CnCpidToInterfaceEntry 4 }
-- ******************************************************************
-- The Reaction Point Port table. One table per end station. One
-- entry per Port per CNPV.
-- ******************************************************************
ieee8021CnRpPortPriTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnRpPortPriEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row in this table supplies values for all of the
Reaction Points (RPs) on one Port and one priority of an end
station or Bridge component. This table is indexed by
component, port (interface), and priority.
Creating an entry in ieee8021CnCompntPriTable can create an
entry in this table, with the default values, on all ports
in the end station.
Deleting the an entry in ieee8021CnCompntPriTable for a
CNPV passing through the RP controlled by this entry deletes
entries on some or all of the ports in the end station.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnRpPortPriIfIndex.
"
REFERENCE
"12.21.5"
::= { ieee8021CnMIBObjects 7 }
ieee8021CnRpPortPriEntry
OBJECT-TYPE
SYNTAX Ieee8021CnRpPortPriEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Reaction Point table controls all of the
Reaction Points on a port in an end station that share the same
priority value.
"
REFERENCE
"12.21.5"
INDEX { ieee8021CnRpPortPriComponentId, ieee8021CnRpPortPriPriority,
ieee8021CnRpPortPriIfIndex
}
::= { ieee8021CnRpPortPriTable 1 }
Ieee8021CnRpPortPriEntry
::= SEQUENCE {
ieee8021CnRpPortPriComponentId IEEE8021PbbComponentIdentifier,
ieee8021CnRpPortPriPriority IEEE8021PriorityValue,
ieee8021CnRpPortPriIfIndex InterfaceIndex,
ieee8021CnRpPortPriMaxRps Unsigned32,
ieee8021CnRpPortPriCreatedRps Counter32,
ieee8021CnRpPortPriCentiseconds Counter64
}
ieee8021CnRpPortPriComponentId
OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge component within the system to which the information
in this ieee8021CnRpGroupEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
::= { ieee8021CnRpPortPriEntry 1 }
ieee8021CnRpPortPriPriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the lowest numerical
Congestion Notification Priority Value that this entry's
Reaction Point serves.
"
REFERENCE
"12.21.5"
::= { ieee8021CnRpPortPriEntry 2 }
ieee8021CnRpPortPriIfIndex
OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the interface on which the selected
Reaction Points reside.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this object, and rearrange the order of the
ieee8021CnRpPortPriTable, so that the value in
ieee8021CnRpPortPriIfIndex references the row in the ifXTable
with the same value for ifAlias that it referenced before the
system restart. If no such entry exists in the ifXTable, then
the system SHALL delete the row in the
ieee8021CnRpPortPriTable.
"
REFERENCE
"12.21.5"
::= { ieee8021CnRpPortPriEntry 3 }
ieee8021CnRpPortPriMaxRps
OBJECT-TYPE
SYNTAX Unsigned32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An integer controlling the maximum number of Reaction Points
allowed for this CNPV on this Port. An end station SHALL
not create more than this many Reaction Point on this Port,
but it MAY create fewer.
"
REFERENCE
"32.10.1"
DEFVAL { 1 }
::= { ieee8021CnRpPortPriEntry 4 }
ieee8021CnRpPortPriCreatedRps
OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of times any of the
Reaction Points (RPs) controlled by this entry has had
its rpEnabled variable set TRUE by the reception of a
Congestion Notification Message.
Dividing the change in ieee8021CnRpPortPriCentiseconds by the
change in this object over a time interval yields the average
lifetime of an active RP during that interval.
"
REFERENCE
"32.10.2, 32.10.3, 32.13.1"
::= { ieee8021CnRpPortPriEntry 5 }
ieee8021CnRpPortPriCentiseconds
OBJECT-TYPE
SYNTAX Counter64
UNITS "centiseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the total number of centi-seconds that
any of the Reaction Points (RPs) controlled by this entry
has had its rpEnabled variable in the TRUE state. That is,
once each centi-second, this counter is incremented by the
number of RPs this entry controls that are actively rate
limiting output frames.
Dividing the change in this object over a time interval by the
length of the interval yields the average number of RPs active
over that interval. Dividing the change in this object by the
change in ieee8021CnRpPortPriCreatedRps over that same time
interval yields the average lifetime of an active RP during that
interval.
"
REFERENCE
"32.10.3, 32.13.1"
::= { ieee8021CnRpPortPriEntry 6 }
-- ******************************************************************
-- The Reaction Point Group table. One table per end station.
-- One entry per Reaction Point.
-- ******************************************************************
ieee8021CnRpGroupTable
OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CnRpGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row in this table supplies values for one or more
Reaction Points (RPs). This table is indexed by component,
port (interface), and an arbitrary RP index.
Creating an entry in ieee8021CnCompntPriTable can create an
entry in this table, with the default values, on all ports
in the end station. An end station can have more than one
RP for the same Congestion Notification Priority Value
(CNPV), so creating an entry in ieee8021CnCompntPriTable can
create multiple entries in this table.
Because each port in a Bridge component or end station can have
a different relationship between CNPVs and RPs, the entries
created or deleted on each port can be different.
Deleting the an entry in ieee8021CnCompntPriTable for a
CNPV passing through the RP controlled by this entry deletes
entries on some or all of the ports in the end station.
Because each port in an end station can have a
different relationship between CNPVs and RPs, the entries
created or deleted on each port can be different.
The relationship between ieee8021CnRpgIdentifier
values and RPs is an implementation dependent matter.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnRpgIfIndex.
"
REFERENCE
"12.21.6"
::= { ieee8021CnMIBObjects 8 }
ieee8021CnRpGroupEntry
OBJECT-TYPE
SYNTAX Ieee8021CnRpGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Reaction Point table controls a group of
Reaction Points, on a port in an end station. All of the
Reaction Point controlled by this entry serve the same
Congestion Notification Priority Value.
"
INDEX { ieee8021CnRpgComponentId, ieee8021CnRpgPriority,
ieee8021CnRpgIfIndex, ieee8021CnRpgIdentifier }
::= { ieee8021CnRpGroupTable 1 }
Ieee8021CnRpGroupEntry
::= SEQUENCE {
ieee8021CnRpgComponentId IEEE8021PbbComponentIdentifier,
ieee8021CnRpgPriority IEEE8021PriorityValue,
ieee8021CnRpgIfIndex InterfaceIndex,
ieee8021CnRpgIdentifier Unsigned32,
ieee8021CnRpgEnable TruthValue,
ieee8021CnRpgTimeReset TimeInterval,
ieee8021CnRpgByteReset Unsigned32,
ieee8021CnRpgThreshold Unsigned32,
ieee8021CnRpgMaxRate Unsigned32,
ieee8021CnRpgAiRate Unsigned32,
ieee8021CnRpgHaiRate Unsigned32,
ieee8021CnRpgGd Integer32,
ieee8021CnRpgMinDecFac Unsigned32,
ieee8021CnRpgMinRate Unsigned32
}
ieee8021CnRpgComponentId
OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge component within the system to which the information
in this ieee8021CnRpGroupEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
"
::= { ieee8021CnRpGroupEntry 1 }
ieee8021CnRpgPriority
OBJECT-TYPE
SYNTAX IEEE8021PriorityValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the lowest numerical
Congestion Notification Priority Value that this entry's
Reaction Point serves.
"
REFERENCE
"12.21.5"
::= { ieee8021CnRpGroupEntry 2 }
ieee8021CnRpgIfIndex
OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the interface on which the group of
Reaction Points reside.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this object, and rearrange the order of the
ieee8021CnRpGroupTable, so that the value in
ieee8021CnRpgIfIndex references the row in the ifXTable with
the same value for ifAlias that it referenced before the system
restart. If no such entry exists in the ifXTable, then the
system SHALL delete the row in the ieee8021CnRpGroupTable.
"
REFERENCE
"12.21.5"
::= { ieee8021CnRpGroupEntry 3 }
ieee8021CnRpgIdentifier
OBJECT-TYPE
SYNTAX Unsigned32 (1..4096)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is an arbitrary integer indexing the entries in
this table among the entries for the same interface. This
index SHOULD, where possible, be equal to the
Congestion Notification Priority Value served by this
Reaction Point.
"
REFERENCE
"12.21.6"
::= { ieee8021CnRpGroupEntry 4 }
ieee8021CnRpgEnable
OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the rpEnabled variable of the Reaction Point state
machines of the Reaction Points (RPs) controlled by this
entry as follows:
true(1) The rpEnabled variable for the RPs controlled by
this object are not held in the FALSE state,
thus enabling them to pay attention to received
CNMs.
false(2) The rpEnabled variable for the RPs controlled by
this object are held in the FALSE state, thus
disabling them from paying attention to received
CNMs.
"
REFERENCE
"32.11.1, 32.13.1"
DEFVAL { true }
::= { ieee8021CnRpGroupEntry 5 }
ieee8021CnRpgTimeReset
OBJECT-TYPE
SYNTAX TimeInterval
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the value for all of the state machine
variables, rpgTimeReset, used to reset the timers RpWhile.
"
REFERENCE
"32.11.2"
DEFVAL { 15 }
::= { ieee8021CnRpGroupEntry 6 }
ieee8021CnRpgByteReset
OBJECT-TYPE
SYNTAX Unsigned32
UNITS "octets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the value for all of the state machine
variables, rpgByteReset, used to reset the counters
rpByteCount.
"
REFERENCE
"32.11.3"
DEFVAL { 150000 }
::= { ieee8021CnRpGroupEntry 7 }
ieee8021CnRpgThreshold
OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the number of times rpByteStage or
rpTimeStage can count before the
RP rate control state machine advances states.
"
REFERENCE
"32.11.4"
DEFVAL { 5 }
::= { ieee8021CnRpGroupEntry 8 }
ieee8021CnRpgMaxRate
OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Mb/s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the maximum rate, in multiples of 1 Mb/s,
at which an RP can transmit. Default value is the speed of the
port. A system SHALL support a minimim value for this object
that is no larger than 5 Mbits/s (object value 5). This rate
includes all bits consequent to transmitting the frame on the
LAN, including preamble, inter-frame gap, etc.
"
REFERENCE
"32.11.5"
::= { ieee8021CnRpGroupEntry 9 }
ieee8021CnRpgAiRate
OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Mb/s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the transmission rate increment in the
RPR_ACTIVE_INCREASE state (rpgAiRate) in multiples of 1 Mb/s.
This rate includes all bits consequent to transmitting the
frame on the LAN, including preamble, inter-frame gap, etc.
"
REFERENCE
"32.11.6"
DEFVAL { 5 }
::= { ieee8021CnRpGroupEntry 10 }
ieee8021CnRpgHaiRate
OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Mb/s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the transmission rate increment in the
RPR_HYPER_INCREASE state (rpgHaiRate) in multiples of 1 Mb/s.
This rate includes all bits consequent to transmitting the
frame on the LAN, including preamble, inter-frame gap, etc.
"
REFERENCE
"32.11.7"
DEFVAL { 50 }
::= { ieee8021CnRpGroupEntry 11 }
ieee8021CnRpgGd
OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the number of bits that the value of the
Quantized Feedback field received in a CNM PDU is shifted to
the right to decrease rpTargetRate. rpgGd is thus 2 to the
negative power of this object, e.g., 7 means rpgGd = 1/128.
"
REFERENCE
"32.11.8"
DEFVAL { 7 }
::= { ieee8021CnRpGroupEntry 12 }
ieee8021CnRpgMinDecFac
OBJECT-TYPE
SYNTAX Unsigned32 (1..100)
UNITS "percent"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the minimum factor by which the current
RP transmit rate rpCurrentRate can be changed by reception
of a Congestion Notification Message. Its integer value
represents a percentage, from 1% to 100%.
"
REFERENCE
"32.11.9"
DEFVAL { 50 }
::= { ieee8021CnRpGroupEntry 13 }
ieee8021CnRpgMinRate
OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Mb/s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the minimum transmission rate (rpgMinRate)
in multiples of 1 Mb/s. A system SHALL support a value for
this object that is no larger than 5 Mb/s per second.
This rate includes all bits consequent to transmitting the
frame on the LAN, including preamble, inter-frame gap, etc.
"
REFERENCE
"32.11.10"
DEFVAL { 5 }
::= { ieee8021CnRpGroupEntry 14 }
-- ******************************************************************
-- IEEE 802.1Qau MIB Module - Conformance Information
-- ******************************************************************
ieee8021CnCompliances
OBJECT IDENTIFIER ::= { ieee8021CnConformance 1 }
ieee8021CnGroups
OBJECT IDENTIFIER ::= { ieee8021CnConformance 2 }
-- ******************************************************************
-- Units of conformance
-- ******************************************************************
ieee8021CnGlobalReqdGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnGlobalMasterEnable,
ieee8021CnComPriLldpInstanceChoice,
ieee8021CnComPriLldpInstanceSelector
}
STATUS current
DESCRIPTION
"Objects in the global required group."
::= { ieee8021CnGroups 1 }
ieee8021CnCpGlobalGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnGlobalCnmTransmitPriority,
ieee8021CnGlobalDiscardedFrames
}
STATUS current
DESCRIPTION
"Objects in the Congestion Point global group."
::= { ieee8021CnGroups 2 }
ieee8021CnCpidTranslateGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnCpidToIfComponentId,
ieee8021CnCpidToIfIfIndex,
ieee8021CnCpidToIfCpIndex
}
STATUS current
DESCRIPTION
"Objects in the CPID translate group."
::= { ieee8021CnGroups 3 }
ieee8021CnEplGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnEpIfIndex
}
STATUS current
DESCRIPTION
"Objects for the Errored Ports Table group."
::= { ieee8021CnGroups 4 }
ieee8021CnComPriGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnComPriDefModeChoice,
ieee8021CnComPriAdminDefenseMode,
ieee8021CnComPriCreation,
ieee8021CnComPriRowStatus
}
STATUS current
DESCRIPTION
"Objects for the global per-priority group."
::= { ieee8021CnGroups 5 }
ieee8021CnCpPriGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnComPriAlternatePriority,
ieee8021CnComPriAutoAltPri
}
STATUS current
DESCRIPTION
"Objects for the Congestion Point per-priority group."
::= { ieee8021CnGroups 6 }
ieee8021CnGlobalPriPortGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnPortPriDefModeChoice,
ieee8021CnPortPriAdminDefenseMode,
ieee8021CnPortPriAutoDefenseMode,
ieee8021CnPortPriLldpInstanceChoice,
ieee8021CnPortPriLldpInstanceSelector
}
STATUS current
DESCRIPTION
"Objects for the global per-priority per-port group."
::= { ieee8021CnGroups 7 }
ieee8021CnCpPriPortGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnPortPriAlternatePriority
}
STATUS current
DESCRIPTION
"Objects for the Congestion Point per-priority per-port
group.
"
::= { ieee8021CnGroups 8 }
ieee8021CnCpGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnCpPriority,
ieee8021CnCpMacAddress,
ieee8021CnCpIdentifier,
ieee8021CnCpQueueSizeSetPoint,
ieee8021CnCpFeedbackWeight,
ieee8021CnCpMinSampleBase,
ieee8021CnCpDiscardedFrames,
ieee8021CnCpTransmittedFrames,
ieee8021CnCpTransmittedCnms,
ieee8021CnCpMinHeaderOctets
}
STATUS current
DESCRIPTION
"Objects for the Congestion Point group."
::= { ieee8021CnGroups 9 }
ieee8021CnRpppGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnRpPortPriMaxRps,
ieee8021CnRpPortPriCreatedRps,
ieee8021CnRpPortPriCentiseconds
}
STATUS current
DESCRIPTION
"Objects for the Reaction Point per-Port per-priority group."
::= { ieee8021CnGroups 10 }
ieee8021CnRpGroup
OBJECT-GROUP
OBJECTS {
ieee8021CnRpgEnable,
ieee8021CnRpgTimeReset,
ieee8021CnRpgByteReset,
ieee8021CnRpgThreshold,
ieee8021CnRpgMaxRate,
ieee8021CnRpgAiRate,
ieee8021CnRpgHaiRate,
ieee8021CnRpgGd,
ieee8021CnRpgMinDecFac,
ieee8021CnRpgMinRate
}
STATUS current
DESCRIPTION
"Objects for the Reaction Point group."
::= { ieee8021CnGroups 11 }
-- ******************************************************************
-- MIB Module Compliance statements
-- ******************************************************************
ieee8021CnBridgeCompliance
MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for support by a Bridge of
the IEEE8021-MIRP-MIB module."
MODULE SNMPv2-MIB -- The SNMPv2-MIB, RFC 3418
MANDATORY-GROUPS {
systemGroup
}
MODULE IF-MIB -- The interfaces MIB, RFC 2863
MANDATORY-GROUPS {
ifGeneralInformationGroup
}
MODULE
MANDATORY-GROUPS {
ieee8021CnGlobalReqdGroup,
ieee8021CnCpGlobalGroup,
ieee8021CnCpidTranslateGroup,
ieee8021CnEplGroup,
ieee8021CnComPriGroup,
ieee8021CnCpPriGroup,
ieee8021CnGlobalPriPortGroup,
ieee8021CnCpPriPortGroup,
ieee8021CnCpGroup
}
OBJECT ieee8021CnComPriRowStatus
SYNTAX RowStatus { active(1), notInService(2),
notReady(3) }
WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),
destroy(6) }
DESCRIPTION "Support for createAndWait is not required."
::= { ieee8021CnCompliances 1 }
ieee8021CnStationCompliance
MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for support by an end station of
the IEEE8021-MIRP-MIB module."
MODULE SNMPv2-MIB -- The SNMPv2-MIB, RFC 3418
MANDATORY-GROUPS {
systemGroup
}
MODULE IF-MIB -- The interfaces MIB, RFC 2863
MANDATORY-GROUPS {
ifGeneralInformationGroup
}
MODULE
MANDATORY-GROUPS {
ieee8021CnGlobalReqdGroup,
ieee8021CnComPriGroup,
ieee8021CnGlobalPriPortGroup,
ieee8021CnRpppGroup,
ieee8021CnRpGroup
}
GROUP ieee8021CnCpGlobalGroup
DESCRIPTION
"This group is optional and supports end stations that
choose to implement Congestion Points."
GROUP ieee8021CnCpidTranslateGroup
DESCRIPTION
"This group is optional and supports end stations that
choose to implement Congestion Points."
GROUP ieee8021CnEplGroup
DESCRIPTION
"This group is optional and supports end stations that
choose to implement Congestion Points."
GROUP ieee8021CnCpPriGroup
DESCRIPTION
"This group is optional and supports end stations that
choose to implement Congestion Points."
GROUP ieee8021CnCpPriPortGroup
DESCRIPTION
"This group is optional and supports end stations that
choose to implement Congestion Points."
GROUP ieee8021CnCpGroup
DESCRIPTION
"This group is optional and supports end stations that
choose to implement Congestion Points."
::= { ieee8021CnCompliances 2 }
END