Observium_CE/mibs/raisecom/SWITCH-INTERFACE-PORT-MIB

710 lines
24 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

------------------------------------------------------------------------------
------------------------------------------------------------------------------
--
-- File : switch-port-mib.mib
-- Description : rose software port command mib defination
-- Version : 0.1
-- Date : Dec 3, 2008
--
-- Copyright (c) 2003-2004 Beijing Raisecom Science & Technology Co., ltd All Rights Reserved.
--
-- *****************************************************************
-- *****************************************************************
-- Modi Report£ºFormat: <number>, <time>, <author>, <desc>
-- 03, 20121226, renxiaoqiang, PHY enhance
-- 02, 20120923, yingjiangang, PHY
-- 01, 20110726, yangzhognhong, add new enum value for nodes rcIfPortMAUType rcIfPortMAUSpeedSet and
-- rcIfPortPHYSpeedGet to support the 10G interface
--
------------------------------------------------------------------------------
------------------------------------------------------------------------------
SWITCH-INTERFACE-PORT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, Counter32,
NOTIFICATION-TYPE FROM SNMPv2-SMI
TruthValue FROM SNMPv2-TC
OBJECT-GROUP FROM SNMPv2-CONF
rcSystem FROM SWITCH-SYSTEM-MIB
EnableVar FROM SWITCH-TC;
rcIfPortInfoConfig MODULE-IDENTITY
LAST-UPDATED "0812030000Z" -- Dec 03, 2008
ORGANIZATION "Raisecom Science & Technology Co., ltd"
CONTACT-INFO "Raisecom Science & Technology Co., ltd.
E-mail: support@raisecom.com"
DESCRIPTION "iscom switch system interface port Enterprise MIB definition."
REVISION "0812030000Z" -- Dec 03, 2008
DESCRIPTION "Initial MIB creation."
::= { rcSystem 7 }
-- If port Group
rcIfPortPHYInfoConfig OBJECT IDENTIFIER ::= { rcIfPortInfoConfig 1 }
-- PHY related function Group
rcIfPortPHYNotifications OBJECT IDENTIFIER ::= { rcIfPortPHYInfoConfig 1 }
rcIfPortPHYInfomation OBJECT IDENTIFIER ::= { rcIfPortPHYInfoConfig 2 }
rcIfPortConnectorInsertTrap NOTIFICATION-TYPE
OBJECTS { rcIfPortPHYIndex, rcIfPortMAUIndex}
STATUS current
DESCRIPTION
"port connector insert trap."
::= { rcIfPortPHYNotifications 1 }
rcIfPortConnectorRemoveTrap NOTIFICATION-TYPE
OBJECTS { rcIfPortPHYIndex, rcIfPortMAUIndex}
STATUS current
DESCRIPTION
"port connector delete trap."
::= { rcIfPortPHYNotifications 2 }
-- if Port PHY table
rcIfPortPHYTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcIfPortPHYEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of switch port and associated properties."
::= { rcIfPortPHYInfomation 1 }
rcIfPortPHYEntry OBJECT-TYPE
SYNTAX RcIfPortPHYEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing PHY management information applicable to a particular
interface port."
INDEX { rcIfPortPHYIndex }
::= { rcIfPortPHYTable 1 }
RcIfPortPHYEntry ::= SEQUENCE {
rcIfPortPHYIndex INTEGER,
rcIfPortPHYExistence TruthValue,
rcIfPortPHYMAUNum INTEGER,
rcIfPortPHYAdminStatus INTEGER,
rcIfPortPHYOperStatus INTEGER,
rcIfPortPHYSpeedGet INTEGER,
rcIfPortPHYDuplexGet INTEGER,
rcIfPortPHYFlowControlRecvStatus EnableVar,
rcIfPortPHYFlowControlSendStatus EnableVar,
rcIfPortPHYMdiStatus INTEGER,
rcIfPortPHYActiveMAUIndex INTEGER,
rcComboPortMediaMode INTEGER,
rcComboPortMediaPriority INTEGER,
rcComboPortMediaActive INTEGER,
rcIfPortSfpAutoDetect INTEGER,
rcIfPortSfpPortTypeGet INTEGER,
rcIfPortPHYEEEAutoGet INTEGER
}
rcIfPortPHYIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each port in the managed system."
::= { rcIfPortPHYEntry 1 }
-- ¶Ë¿ÚÏÂPHY´æÔÚ״̬
rcIfPortPHYExistence OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value of false(2) is returned, if there is no PHY in the port."
::= { rcIfPortPHYEntry 2 }
-- ¶Ë¿ÚÏ MAUÊýÁ¿
rcIfPortPHYMAUNum OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAU number in the port. A value 0 is returned, if there is no PHY in the port.
a value more than 1 is returned ,if the port is combo port."
::= { rcIfPortPHYEntry 3 }
-- ¶Ë¿Ú¹¦ÄܹÜÀí״̬
rcIfPortPHYAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired state of the port."
DEFVAL{up}
::= { rcIfPortPHYEntry 4 }
-- ¶Ë¿Ú¹¦ÄܲÙ×÷״̬
rcIfPortPHYOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the port. If rcIfPortPHYAdminStatus is down(2)
then rcIfPortOperStatus should be down(2). While rcIfPortPHYAdminStatus is
changed to up(1), rcIfPortPHYOperStatus should remain in the down(2) state if
and only if there is a fault that prevents it from going to the up(1) state
(e.g. Loopback-detection module detects a loop in this port )."
::= { rcIfPortPHYEntry 5 }
-- ¶Ë¿ÚËÙÂʲÙ×÷״̬
rcIfPortPHYSpeedGet OBJECT-TYPE
SYNTAX INTEGER
{
illegal(0),
unknown(1),
speed-10M(2),
speed-100M(3),
speed-1000M(4),
speed-10G(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual speed state of the active MAU in the port. A value of illegal(0)
is retuned if the interface port is not configured for an acceptable value.
A value of unknown(1) is returned when rcIfPortPHYOperStatus indicates
down(2) for this interface port."
::= { rcIfPortPHYEntry 6 }
-- ¶Ë¿ÚË«¹¤²Ù×÷״̬
rcIfPortPHYDuplexGet OBJECT-TYPE
SYNTAX INTEGER
{
illegal(0),
unknown(1),
half(2),
full(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual duplex state of the active MAU in the port. A value of illegal(0)
is retuned if the interface port is not configured for an acceptable value.
A value of unknown(1) is returned when rcIfPortPHYOperStatus indicates
down(2) for this interface port."
::= { rcIfPortPHYEntry 7 }
-- ¶Ë¿Ú½ÓÊÕPAUSEÖ¡·½ÏòÁ÷¿Ø²Ù×÷״̬
rcIfPortPHYFlowControlRecvStatus OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual flow control state in receiving direction."
::= { rcIfPortPHYEntry 8 }
-- ¶Ë¿Ú·¢ËÍPAUSEÖ¡·½ÏòÁ÷¿Ø²Ù×÷״̬
rcIfPortPHYFlowControlSendStatus OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual flow control state in sending direction."
::= { rcIfPortPHYEntry 9 }
-- ¶Ë¿ÚMDIÏßÐò²Ù×÷״̬
rcIfPortPHYMdiStatus OBJECT-TYPE
SYNTAX INTEGER
{
illegal(0),
unknown(1),
normal(2),
xover(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual automatic MDI crossover state. A value of illegal(0)
is retuned if the interface port is not configured for an
acceptable value."
::= { rcIfPortPHYEntry 10 }
-- ¶Ë¿ÚÏ»MAUµÄË÷Òý
rcIfPortPHYActiveMAUIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of active MAU in the port."
::= { rcIfPortPHYEntry 11 }
-- ¶Ë¿Úcombo¿Ú½éÖÊÀàÐÍ
rcComboPortMediaMode OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
auto(1),
fiber-forced(2),
copper-forced(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The mode of combo."
::= { rcIfPortPHYEntry 12 }
-- ¶Ë¿Úcombo¿Ú½éÖÊÓÅÏȼ¶
rcComboPortMediaPriority OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
fiber(1),
copper(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates which types of media has higher priority to be active than another one."
::= { rcIfPortPHYEntry 13 }
-- ¶Ë¿Úcombo¿Ú¼¤»î½éÖÊÀàÐÍ
rcComboPortMediaActive OBJECT-TYPE
SYNTAX INTEGER{
unavailable(0),
fiber(1),
copper(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Used to identify whether this Combo port currently be in the active state."
::= { rcIfPortPHYEntry 14 }
-- ¶Ë¿ÚSFP×Ô¶¯¼ì²âʹÄÜÉèÖÃ
rcIfPortSfpAutoDetect OBJECT-TYPE
SYNTAX INTEGER{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to identify whether this port is in sfp auto-detect mode."
::= { rcIfPortPHYEntry 15 }
-- ¶Ë¿ÚSFPÁ¬½ÓÀàÐÍ
rcIfPortSfpPortTypeGet OBJECT-TYPE
SYNTAX INTEGER{
unknown(0),
copper(1),
fiber100(2),
fiber1000(3),
fiber10000(4)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The SFP fiber mode operator state."
::= { rcIfPortPHYEntry 16 }
-- ¶Ë¿ÚEEE-Auto²Ù×÷ģʽ
rcIfPortPHYEEEAutoGet OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"EEE-Auto Operate Mode."
::= { rcIfPortPHYEntry 17 }
-- if Port MAU table
rcIfPortMAUTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcIfPortMAUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of switch port and associated properties."
::= { rcIfPortPHYInfomation 2 }
rcIfPortMAUEntry OBJECT-TYPE
SYNTAX RcIfPortMAUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information for a particular MAU in the port."
INDEX { rcIfPortPHYIndex, rcIfPortMAUIndex}
::= { rcIfPortMAUTable 1 }
RcIfPortMAUEntry ::= SEQUENCE {
rcIfPortMAUIndex INTEGER,
rcIfPortMAUType INTEGER,
rcIfPortMAUConnectorType INTEGER,
rcIfPortMAUConnectorStatus INTEGER,
rcIfPortMAUSpeedSet INTEGER,
rcIfPortMAUDuplexSet INTEGER,
rcIfPortMAUFlowControlEnable EnableVar,
rcIfPortMAUFlowControlRecvEnable EnableVar,
rcIfPortMAUFlowControlSendEnable EnableVar,
rcIfPortMAUMdiMode INTEGER,
rcIfPortMAUStatus INTEGER,
rcIfPortMAUSfpPortType INTEGER,
rcIfPortEEEAutoMode INTEGER
}
-- Ö¸¶¨MAUµÄË÷Òý
rcIfPortMAUIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index based 1 that uniquely identifies a MAU from the other
MAUs in the port. It should be less than rcIfPortPHYMAUNum
in the port."
::= { rcIfPortMAUEntry 1 }
-- Ö¸¶¨MAUµÄÀàÐÍ
rcIfPortMAUType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
dot3-10BASE-T(5),
dot3-100BASE-TX(16),
dot3-100BASE-FX(18),
dot3-1000BASE-X(22),
dot3-1000BASE-T(30),
dot3-10GBASE-X(31),
dot3-10GBASE-R(33),
dot3-10GBASE-W(37),
rc-1000BASE-P(99),
dot3-1000BASE-T1(100),
dot3-1000BASE-T2(101)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the MAU type and indicates capability.
values for MAU types above are defined in standard IEEE 802.3
DOT3-MAU-MIB.my(RFC 3636). It can respect MAU capability and
media information.Specially,dot3-1000BASE-T1 indicates 1000BASE-T
only support auto-negotiation,and dot3-1000BASE-T2 indicates
1000BASE-T only support 1000M and full-duplex.'unknown' indicates
it is uncertain"
::= { rcIfPortMAUEntry 2 }
-- Ö¸¶¨MAUµÄÁ¬½ÓÆ÷ÀàÐÍ
rcIfPortMAUConnectorType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
other(1),
sfp(2),
sfp-plus(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the MAU connector type."
::= { rcIfPortMAUEntry 3 }
-- Ö¸¶¨MAUµÄÁ¬½ÓÆ÷״̬
rcIfPortMAUConnectorStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
error(1),
not-present(2),
present(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the MAU connector status. A value of unknown(0)
is returned if the connector can not been identified. A value of
error(1) is returned if the connector type is can not been
supported by the MAU. A value present(2) is returned if the connector
is connected to the MAU."
::= { rcIfPortMAUEntry 4 }
-- Ö¸¶¨MAUµÄËÙÂʹÜÀí״̬
rcIfPortMAUSpeedSet OBJECT-TYPE
SYNTAX INTEGER
{
auto-negotiate(1),
speed-10M(2),
speed-100M(3),
speed-1000M(4),
speed-10G(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired speed state for the MAU. Some MAU may not support
setting the value of this object to some of the enumerated values."
DEFVAL{auto-negotiate}
::= { rcIfPortMAUEntry 5 }
-- Ö¸¶¨MAUµÄË«¹¤¹ÜÀí״̬
rcIfPortMAUDuplexSet OBJECT-TYPE
SYNTAX INTEGER
{
auto-negotiate(1),
half(2),
full(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired duplex state of the MAU. Some MAU may not support
setting the value of this object to some of the enumerated values."
DEFVAL{auto-negotiate}
::= { rcIfPortMAUEntry 6 }
-- Ö¸¶¨MAUµÄ¶Ô³ÆÁ÷¿Ø¹ÜÀí״̬
rcIfPortMAUFlowControlEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set symmetric flow control of the MAU to enable(1) or disable(2)."
DEFVAL{disable}
::= { rcIfPortMAUEntry 7 }
-- Ö¸¶¨MAUµÄ½ÓÊÕPAUSEÖ¡Á÷¿Ø¹ÜÀí״̬
rcIfPortMAUFlowControlRecvEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the flow control in receiving direction to enable(1) or disable(2)."
DEFVAL{ disable }
::= { rcIfPortMAUEntry 8 }
-- Ö¸¶¨MAUµÄ·¢ËÍPAUSEÖ¡Á÷¿Ø¹ÜÀí״̬
rcIfPortMAUFlowControlSendEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the flow control in sending direction to enable(1) or disable(2)."
DEFVAL{ disable }
::= { rcIfPortMAUEntry 9 }
-- Ö¸¶¨MAUµÄMDIÏßÐò¹ÜÀí״̬
rcIfPortMAUMdiMode OBJECT-TYPE
SYNTAX INTEGER
{
auto-detect(1),
normal(2),
xover(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired automatic MDI crossover mode of the MAU. Some MAU may
not support setting the value of this object to some of the
enumerated values."
DEFVAL{ auto-detect }
::= { rcIfPortMAUEntry 10 }
-- Ö¸¶¨MAUµÄMDIÏßÐò¹ÜÀí״̬
rcIfPortMAUStatus OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
suspend(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The actual state of the MAU. In a combo port, only one MAU
in the port can operate in active state. This object dose not
support writing operation yet!"
::= { rcIfPortMAUEntry 11 }
-- Ö¸¶¨MAUµÄ¶Ë¿ÚSFPÁ¬½ÓÀàÐÍ
rcIfPortMAUSfpPortType OBJECT-TYPE
SYNTAX INTEGER{
autodetect(0),
copper(1),
fiber100(2),
fiber1000(3),
fiber10000(4)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The SFP fiber mode admin state."
::= { rcIfPortMAUEntry 12 }
-- Ö¸¶¨MAUµÄ¶Ë¿ÚEEE-Autoģʽ
rcIfPortEEEAutoMode OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"EEE-Auto Admin Mode."
::= { rcIfPortMAUEntry 13 }
--Combo port table
rcComboMediaTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcComboMediaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Combo port and associated properties."
::= { rcIfPortPHYInfomation 3 }
rcComboMediaEntry OBJECT-TYPE
SYNTAX RcComboMediaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for Combo media status information."
INDEX { rcComboPortId, rcComboPortMedia }
::= { rcComboMediaTable 1 }
RcComboMediaEntry ::= SEQUENCE {
rcComboPortId INTEGER,
rcComboPortMedia INTEGER,
rcComboPortDescription OCTET STRING,
rcComboPortSpeed INTEGER,
rcComboPortDuplex INTEGER,
rcComboPortFlowCtrl EnableVar,
rcComboPortSendFlowCtrl EnableVar,
rcComboPortRecvFlowCtrl EnableVar,
rcComboPortMdiXMode INTEGER
}
rcComboPortId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index based 1 that uniquely identifies a Ether like interface."
::= { rcComboMediaEntry 1 }
--¶Ë¿ÚcomboÀàÐÍ
rcComboPortMedia OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
fiber(1),
copper(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index based 1 that uniquely identifies a Ether like interface."
::= { rcComboMediaEntry 2 }
--¶Ë¿ÚcomboÃèÊö
rcComboPortDescription OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The description of a combo interface of the swtich."
::= { rcComboMediaEntry 3 }
--¶Ë¿Úcombo¿ÚËÙÂÊÅäÖÃ
rcComboPortSpeed OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
Auto-negotiate(1),
speed-10M(2),
speed-100M(3),
speed-1000M(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configurated speed for this interface."
DEFVAL { 1 }
::= { rcComboMediaEntry 4 }
--¶Ë¿Úcombo¿ÚË«¹¤ÅäÖÃ
rcComboPortDuplex OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
auto-negotiate(1),
half (2),
full (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configurated duplex for this interface."
DEFVAL { 1 }
::= { rcComboMediaEntry 5 }
--¶Ë¿Úcombo¿Ú¶Ô³ÆÁ÷¿ØÅäÖÃ
rcComboPortFlowCtrl OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
enable(1),
disable(2),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The switch of the flow control on both direction."
::= { rcComboMediaEntry 6 }
--¶Ë¿Úcombo¿Ú·¢ËÍÁ÷¿ØÅäÖÃ
rcComboPortSendFlowCtrl OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
enable(1),
disable(2),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The switch of the flow control on send direction."
::= { rcComboMediaEntry 7 }
--¶Ë¿Úcombo¿Ú½ÓÊÕÁ÷¿ØÅäÖÃ
rcComboPortRecvFlowCtrl OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
enable(1),
disable(2),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The switch of the flow control on receive direction."
::= { rcComboMediaEntry 8 }
--¶Ë¿Úcombo¿ÚmdiÅäÖÃ
rcComboPortMdiXMode OBJECT-TYPE
SYNTAX INTEGER{
not-support(0),
auto(1),
normal(2),
xover(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Automatic MDI Crossover mode of a port/PHY."
DEFVAL { auto }
::= { rcComboMediaEntry 9 }
END