-- RAISECOM-SLA-MIB.mib
--
-- july 2008, wangyuhang
--
-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd.
-- All rights reserved.
-- 02,20121023, guohm, 增加rcmefSoamLastStatsGroup
-- 01,20111221,yangkewei, ROS00008189,修改节点 rcSlaConfigParam说明使之与代码一致
-- *****************************************************************
RAISECOM-SLA-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32,
Counter32,
Counter64,
Unsigned32,
Gauge32,
IpAddress FROM SNMPv2-SMI -- [RFC2578]
TimeStamp,
RowStatus,
TruthValue,
MacAddress FROM SNMPv2-TC -- [RFC2579]
InterfaceIndex FROM IF-MIB -- [RFC2863]
EnableVar FROM SWITCH-TC
VlanId FROM Q-BRIDGE-MIB
iscomSwitch FROM RAISECOM-BASE-MIB
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
Dot1agCfmMepId,
Dot1agCfmMDLevel FROM IEEE8021-CFM-MIB
rcServiceCosLabel FROM SWTICH-SERVICE-MIB
;
rcSla MODULE-IDENTITY
LAST-UPDATED "200711020000Z"
ORGANIZATION "Raisecom, Inc."
CONTACT-INFO
" Raise Systems
Postal: Beijing,
China
Tel: 86-010-82884499
E-mail: wangyuhang@raisecom.com"
DESCRIPTION
"This MIB module defines objects to SLA "
REVISION "200711020000Z"
DESCRIPTION
"The initial revision of this MIB."
::={ iscomSwitch 36 }
--
--
RcSlaCfgOperType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
" Specifies the type of operation to be performed.
The value 'y1731-echo' will cause the application to perform a timed echo y1731
operation directed at the 'rcSlaConfigDestMacAddr' or 'rcSlaConfigRMepId'.
The value 'y1731-jitter' will cause the application to perform delay variance analysis.
The value 'icmp-echo' will cause the application to perform a timed echo icmp
operation directed at the 'rcSlaConfigDestIpAddr'.
The value 'icmp-jitter' will cause the application to perform delay variance analysis.
"
REFERENCE
"rcSla"
SYNTAX INTEGER {
y1731-echo (1),
y1731-jitter (2),
icmp-echo (3),
icmp-jitter (4),
y1731-pkt-loss (5)
}
--
--
RcSlaCfgScheduleStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
" The RcSlaCfgScheduleStatus textual convention is used to manage the
creation and deletion of Schedule.
The status column has five defined values:
- `scheduleInitial', which indicates that the operation dose not be
scheduled ;
- `scheduleCreate', which is supplied by a management station wishing to
create a new schedule and to have its status automatically set to active;
- `scheduleBreak', which is supplied by a management station wishing to
break a scheduling operationand to have its status automatically set to complete;
- `scheduleActive', which indicates that the operation is being scheduled ;
- `scheduleComplete', which indicates that the scheduled operation has been over;
"
REFERENCE
"rcSla"
SYNTAX INTEGER {
scheduleInitial (1),
scheduleCreate (2),
scheduleBreak (3),
scheduleActive (4),
scheduleComplete (5)
}
--
--
RcSlaOWSupport ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
" The type use to decide whether to support one way Test. "
REFERENCE
"rcSla"
SYNTAX INTEGER {
sla-unknown (1),
sla-support (2),
sla-no-support (3)
}
--groupsType
rcSlaObjectsGroup OBJECT IDENTIFIER ::= {rcSla 1}
rcSlaConfigGroup OBJECT IDENTIFIER ::= {rcSla 2}
rcSlaScheduleGroup OBJECT IDENTIFIER ::= {rcSla 3}
rcSlaThroughputGroup OBJECT IDENTIFIER ::= {rcSla 4}
rcSlaThresholdGroup OBJECT IDENTIFIER ::= {rcSla 5}
rcmefSoamLastStatsGroup OBJECT IDENTIFIER ::= {rcSla 6}
rcSlaMaintenanceGroup OBJECT IDENTIFIER ::= {rcSla 7}
rcSlaThresholdProfileGroup OBJECT IDENTIFIER ::= {rcSla 8}
--rcSlaObjectsGroup
-- rcSlaConfigOperSum
-- rcSlaActiveOperSum
-- rcSlaConfigOperSum
rcSlaConfigOperSum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of operation configured "
::= { rcSlaObjectsGroup 1 }
-- rcSlaActiveOperSum
rcSlaActiveOperSum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of active configured "
::= { rcSlaObjectsGroup 2 }
-- rcSlaY1731OperType
rcSlaY1731OperType OBJECT-TYPE
SYNTAX RcSlaCfgOperType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Y.1731 Operation Type : y1731-echo / y1731-jitter"
::= { rcSlaObjectsGroup 3 }
-- rcSlaY1731MDLevel
rcSlaY1731MDLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the maintenance domain level to be used by Y.1731 operation."
::= { rcSlaObjectsGroup 4 }
-- rcSlaY1731SVlanId
rcSlaY1731SVlanId OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the identifier of VLAN for MA to be used by Y.1731 operation.
It is an unique identifier for a service instance
within a Maintenance Domain specified by rcSlaConfigMDLevel."
::= { rcSlaObjectsGroup 5 }
-- rcSlaY1731OperQuickInput
rcSlaY1731OperQuickInput OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Quick creat operation when learning Rmep by Y.1731"
::= { rcSlaObjectsGroup 6 }
-- rcSlaY1731TestPduType
rcSlaY1731TestPduType OBJECT-TYPE
SYNTAX INTEGER {loopBack(1),delayMeasurement(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Quick input test pdu type"
::= { rcSlaObjectsGroup 7 }
--OperConfigGroup --
--rcSlaConfigGroup
--rcSlaConfigTable
--rcSlaConfigEntry
--rcSlaConfigOperId
--rcSlaConfigOwner
--rcSlaOneWaySupport
--rcSlaConfigOperType
--rcSlaConfigCos
--rcSlaConfigCVlanId
--rcSlaConfigSVlanId
--rcSlaConfigMDLevel
--rcSlaConfigRMepId
--rcSlaConfigDestMacAddr
--rcSlaConfigDestIpAddr
--rcSlaConfigJitterInterval
--rcSlaConfigJitterFrameNums
--rcSlaConfigScheduleStartTime
--rcSlaConfigScheduleLife
--rcSlaConfigSchedulePeriod
--rcSlaConfigScheduleStatus
--rcSlaConfigRowStatus
--rcSlaConfigParam
--rcSlaConfigDscp
rcSlaConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains sla control data."
::= { rcSlaConfigGroup 1 }
rcSlaConfigEntry OBJECT-TYPE
SYNTAX RcSlaConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects that define three conceptual
control row : slaY.1731EntryTable, slaIcmpEntryTable, slaSchEntryTable.
The 'slaY.1731EntryTable' is used to control y1731 operation .
The following objects must be specified in order to create this
conceptual row.
- rcSlaConfigOperType
- rcSlaConfigVlanId
- rcSlaConfigMDLevel
- rcSlaConfigDestMacAddr
- rcSlaConfigRMepId
The ' slaIcmpEntryTable' is used to control ICMP operation .
The following objects must be specified in order to create this
conceptual row.
- rcSlaConfigOperType
- rcSlaConfigDestIpAddr
The ' slaIcmpSchTable' is used to control operation schduled."
INDEX { rcSlaConfigOperId }
::={ rcSlaConfigTable 1 }
RcSlaConfigEntry ::= SEQUENCE {
rcSlaConfigOperId Unsigned32,
rcSlaConfigOwner OCTET STRING (SIZE(0..1024)),
rcSlaOneWaySupport RcSlaOWSupport,
rcSlaConfigOperType RcSlaCfgOperType,
rcSlaConfigCos Integer32 (0..7 ),
rcSlaConfigCVlanId VlanId,
rcSlaConfigSVlanId VlanId,
rcSlaConfigMDLevel Dot1agCfmMDLevel,
rcSlaConfigRMepId Dot1agCfmMepId,
rcSlaConfigDestMacAddr MacAddress,
rcSlaConfigDestIpAddr IpAddress,
rcSlaConfigJitterInterval Unsigned32,
rcSlaConfigJitterFrameNums Unsigned32,
rcSlaConfigScheduleStartTime TimeStamp,
rcSlaConfigScheduleLife Unsigned32,
rcSlaConfigSchedulePeriod Unsigned32,
rcSlaConfigScheduleStatus RcSlaCfgScheduleStatus,
rcSlaConfigRowStatus RowStatus,
rcSlaConfigParam OCTET STRING (SIZE(0..255)),
rcSlaConfigTestPduType INTEGER,
rcSlaConfigDscp Integer32 (0..63 ),
rcSlaConfigTestPduLength Integer32 (64..9600 )
}
rcSlaConfigOperId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaConfigEntry 1 }
rcSlaConfigOwner OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..1024))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies a string which used by a managing application
to identify the entity that created this operation."
::= { rcSlaConfigEntry 2 }
rcSlaOneWaySupport OBJECT-TYPE
SYNTAX RcSlaOWSupport
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the type of decision whether to support one way test. "
::= { rcSlaConfigEntry 3 }
rcSlaConfigOperType OBJECT-TYPE
SYNTAX RcSlaCfgOperType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the type of operation to be performed. "
::= { rcSlaConfigEntry 4 }
rcSlaConfigCos OBJECT-TYPE
SYNTAX Integer32 (0..7 )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the Class Of Service field
in an frame header of SLA PDU to be used by Y.1731 operation."
::= { rcSlaConfigEntry 5 }
rcSlaConfigCVlanId OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the CVlan user configured
in an frame header of SLA PDU to be used by Y.1731 operation.
It could be zero when there is no cunsomer vlan"
::= { rcSlaConfigEntry 6 }
rcSlaConfigSVlanId OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the identifier of VLAN for MA to be used by Y.1731 operation.
It is an unique identifier for a service instance
within a Maintenance Domain specified by rcSlaConfigMDLevel."
::= { rcSlaConfigEntry 7 }
rcSlaConfigMDLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the maintenance domain level to be used by Y.1731 operation."
::= { rcSlaConfigEntry 8 }
rcSlaConfigRMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the Target Remote MEP Identify to be used by Y.1731 operation."
::= { rcSlaConfigEntry 9 }
rcSlaConfigDestMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the Target MAC Address Field to be used by Y.1731 operation."
::= { rcSlaConfigEntry 10 }
rcSlaConfigDestIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the Target IP Address Field to be used by ICMP operation."
::= { rcSlaConfigEntry 11 }
rcSlaConfigJitterInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This value specifies the inter-frame delay between Ethernet
frames that need to be transmitted to the target device.
This object is applicable to 'Jitter' operation only."
::= { rcSlaConfigEntry 12 }
rcSlaConfigJitterFrameNums OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the number of frames that need to be transmitted to the target device.
This object is applicable to 'Jitter' operation only."
::= { rcSlaConfigEntry 13 }
rcSlaConfigScheduleStartTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the time when this schedule status will become 'active'.
Value of 0 puts in other status."
::= { rcSlaConfigEntry 14 }
rcSlaConfigScheduleLife OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the time duration over the whole schedule process. "
::= { rcSlaConfigEntry 15 }
rcSlaConfigSchedulePeriod OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the duration between two SLA test
which includes all of probes schedule process in test.
Take above example, if all of the rcSlaConfigSchedulePeriod of three operations are set to 60,
then the start time of each test of SLA operation like:
start time: T+0 -------- T+9 ---------- T+19-----
operation1 operation2 operation3
start again: T+60-------- T+69 ---------- T+79--
operation1 operation2 operation3
start 3rd time:T+120-------- T+129 ----------T+139--
operation1 operation2 operation3"
::= { rcSlaConfigEntry 16 }
rcSlaConfigScheduleStatus OBJECT-TYPE
SYNTAX RcSlaCfgScheduleStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the status of Schedule.
The status column has five defined values:
- `scheduleInitial', which indicates that the operation has not been scheduled ;
- `scheduleCreate', which is supplied by a management station wishing to create a new schedule
and to have its status set to active;
- `scheduleBreak', which is supplied by a management station wishing to break a scheduling operation
and to have its status set to complete;
- `scheduleActive', which indicates that the operation is being scheduled ;
- `scheduleComplete', which indicates that the scheduled operation has been over;"
::= { rcSlaConfigEntry 17 }
rcSlaConfigRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
All columns must have a valid value before a row can be activated.
The following objects must be specified obviously in order for row status object to become active.
rcSlaConfigOperId
rcSlaConfigOperType
For ICMP operation:
rcSlaConfigDestIpAddr
For Y.1731 operation:
rcSlaConfigVlanId
rcSlaConfigMDLevel
rcSlaConfigDestMacAddr
The following objects about the configuration of operation cannot be modified after creating the row:
rcSlaConfigOperId
rcSlaConfigOwner
rcSlaConfigOperType
rcSlaConfigCos
rcSlaConfigVlanId
rcSlaConfigMDLevel
rcSlaConfigDestMacAddr
rcSlaConfigDestIpAddr
rcSlaConfigJitterInterval
rcSlaConfigJitterFrameNums
rcSlaConfigDscp
The following objects about the schedule configuration of operation can be modified even after creating the row:
rcSlaConfigScheduleStartTime
rcSlaConfigScheduleLife
rcSlaConfigSchedulePeriod
rcSlaConfigScheduleStatus
The ahead three objects of above won't be modified until another schedule of this operation start."
::= { rcSlaConfigEntry 18 }
rcSlaConfigParam OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object uses to restore the value of config params which is needed by all kinds of operation.
The meaning of this object decides by different operation :
For Y.1731 operation, this object means:
-- Type (1 - 2) in 0 BYTE
-- Length ,in 1 BYTE
-- mdlevel (0 - 7) in 2 BYTE
-- Cos (0 - 7) in 3 BYTE
-- Svlan (1 - 4094 in 4 - 7 BYTE
-- Cvlan (0 - 4094) in 8 - 11 BYTE
-- RmepId (1 - 8191 ) in 12 - 15 BYTE
-- Dmac , in 12 - 17 BYTE
For ICMP operation:
-- Ipaddress in 0 - 15 BYTE
-- Dscp in 16 - 19 BYTE
Type : the type of destination parameter(1 is Dmac and 2 is RmepId) to be used by Y.1731 operation.
Length : the length of the rcSlaConfigParam string to be used by Y.1731 operation.
mdlevel : the maintenance domain level to be used by Y.1731 operation.
Cos : the Class Of Service field in an frame header of SLA PDU to be used by Y.1731 operation.
Svlan : the identifier of VLAN for MA to be used by Y.1731 operation.
It is an unique identifier for a service instance within a Maintenance Domain specified by rcSlaConfigMDLevel.
Cvlan : the CVlan user configured in an frame header of SLA PDU to be used by Y.1731 operation.
It could be zero when there is no cunsomer vlan
RmepId : the Target Remote MEP Identify to be used by Y.1731 operation.
Dmac the Target Remote MAC Address to be used by Y.1731 operation.
Ipaddress : the Target IP Address Field to be used by ICMP operation.
Dscp: the Differentiated Services Code Point field in header of ip
"
::= { rcSlaConfigEntry 19 }
rcSlaConfigTestPduType OBJECT-TYPE
SYNTAX INTEGER {loopback(1), delayMeasurement(2),lossMeasurement(3),SyntheticLossMeasurement(4)}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object specifies the type of Y1731 echo/jitter packats.
Two types are avalibale:
loopBack (1),
delayMeasurement (2),
lossMeasurement (3),
SyntheticLossMeasurement(4)
"
::= { rcSlaConfigEntry 20 }
rcSlaConfigDscp OBJECT-TYPE
SYNTAX Integer32 (0..63 )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the Differentiated Services Code Point field in header of ip."
::= { rcSlaConfigEntry 21 }
rcSlaConfigTestPduLength OBJECT-TYPE
SYNTAX Integer32 (64..9600 )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the length of test pdus.
This object is only valid for the entity transmitting the Loss
Measurement frames, type 'Slm','DM' and is ignored by the
entity receiving frames. It is not applicable for the 'lmCcm' or
'lmLmm' types."
::= { rcSlaConfigEntry 22 }
--OperScheduleGroup--
--rcSlaScheduleGroup
-- rcSlaLatestTable
--rcSlaLatestEntry
--rcSlaLatestTXNum
--rcSlaLatestRTTNum
--rcSlaLatestRTTSum
--rcSlaLatestRTTSumJitter
--rcSlaLatestRTTSum2
--rcSlaLatestRTTMin
--rcSlaLatestRTTMax
--rcSlaLatestRTTNumSD
--rcSlaLatestRTTSumSD
--rcSlaLatestRTTSumJitterSD
--rcSlaLatestRTTSum2SD
--rcSlaLatestRTTMinSD
--rcSlaLatestRTTMaxSD
--rcSlaLatestRTTNumDS
--rcSlaLatestRTTSumDS
--rcSlaLatestRTTSumJitterDS
--rcSlaLatestRTTSum2DS
--rcSlaLatestRTTMinDS
--rcSlaLatestRTTMaxDS
-- rcSlaStatisticTable
--rcSlaStatisticEntry
--rcSlaStatisticStartTime
--rcSlaStatisticScheduleLife
--rcSlaStatisticSchedulePeriod
--rcSlaStatisticTXNum
--rcSlaStatisticRTTNum
--rcSlaStatisticRTTSums
--rcSlaStatisticRTTSumJitter
--rcSlaStatisticRTTSum2L
--rcSlaStatisticRTTSum2H
--rcSlaStatisticRTTMin
--rcSlaStatisticRTTMax
--rcSlaStatisticRTTNumSD
--rcSlaStatisticRTTSumsSD
--rcSlaStatisticRTTSumJitterSD
--rcSlaStatisticRTTSum2LSD
--rcSlaStatisticRTTSum2HSD
--rcSlaStatisticRTTMinSD
--rcSlaStatisticRTTMaxSD
--rcSlaStatisticRTTNumDS
--rcSlaStatisticRTTSumsDS
--rcSlaStatisticRTTSumJitterDS
--rcSlaStatisticRTTSum2LDS
--rcSlaStatisticRTTSum2HDS
--rcSlaStatisticRTTMinDS
--rcSlaStatisticRTTMaxDS
-- rcSlaPktlmLatestTable
--rcSlaPktlmLatestEntry
--rcSlaLatestPktlmTXNum
--rcSlaLatestPktlmNum
--rcSlaLatestPktlmSum
--rcSlaLatestPktlmMin
--rcSlaLatestPktlmMax
--rcSlaLatestPktlmNumSD
--rcSlaLatestPktlmSumSD
--rcSlaLatestPktlmMinSD
--rcSlaLatestPktlmMaxSD
--rcSlaLatestPktlmNumDS
--rcSlaLatestPktlmSumDS
--rcSlaLatestPktlmMinDS
--rcSlaLatestPktlmMaxDS
--rcSlaPktlmStatisticTable
--rcSlaPktlmStatisticEntry
--rcSlaStatisticPktlmStartTime
--rcSlaStatisticPktlmScheduleLife
--rcSlaStatisticPktlmSchedulePeriod
--rcSlaStatisticPktlmTXNum
--rcSlaStatisticPktlmNum
--rcSlaStatisticPktlmSums
--rcSlaStatisticPktlmMin
--rcSlaStatisticPktlmMax
--rcSlaStatistiPktlmNumSD
--rcSlaStatisticPktlmSumsSD
--rcSlaStatisticPktlmMinSD
--rcSlaStatisticPktlmMaxSD
--rcSlaStatisticPktlmNumDS
--rcSlaStatisticPktlmSumsDS
--rcSlaStatisticPktlmMinDS
--rcSlaStatisticPktlmMaxDS
--rcSlaLatestTable
rcSlaLatestTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaLatestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the statistics calculated for the
latest sent frames."
::= { rcSlaScheduleGroup 1 }
rcSlaLatestEntry OBJECT-TYPE
SYNTAX RcSlaLatestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects that record the latest operation.
An entry is created only when the operation has been set and scheduled.
The entry will start to collect data when rcSlaConfigScheduleStatus
is in 'active' state. The entry will be removed when the
rcSlaConfigScheduleStatus is changed to 'complete' state. "
INDEX { rcSlaConfigOperId }
::={ rcSlaLatestTable 1 }
RcSlaLatestEntry ::= SEQUENCE {
rcSlaLatestTXNum Gauge32,
rcSlaLatestRTTNum Gauge32,
rcSlaLatestRTTSum Gauge32,
rcSlaLatestRTTSumJitter Gauge32,
rcSlaLatestRTTSum2 Gauge32,
rcSlaLatestRTTMin Gauge32,
rcSlaLatestRTTMax Gauge32,
rcSlaLatestRTTNumSD Gauge32,
rcSlaLatestRTTSumSD Gauge32,
rcSlaLatestRTTSumJitterSD Gauge32,
rcSlaLatestRTTSum2SD Gauge32,
rcSlaLatestRTTMinSD Gauge32,
rcSlaLatestRTTMaxSD Gauge32,
rcSlaLatestRTTNumDS Gauge32,
rcSlaLatestRTTSumDS Gauge32,
rcSlaLatestRTTSumJitterDS Gauge32,
rcSlaLatestRTTSum2DS Gauge32,
rcSlaLatestRTTMinDS Gauge32,
rcSlaLatestRTTMaxDS Gauge32
}
rcSlaLatestTXNum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's probe sent in latest test."
::= { rcSlaLatestEntry 1 }
rcSlaLatestRTTNum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's probe that were successfully measured in latest test."
::= { rcSlaLatestEntry 2 }
rcSlaLatestRTTSum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of RTT's delay that were successfully measured in latest test."
::= { rcSlaLatestEntry 3 }
rcSlaLatestRTTSumJitter OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's jitter that were successfully measured in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 4 }
rcSlaLatestRTTSum2 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 5 }
rcSlaLatestRTTMin OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of RTT's that were successfully measured in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 6 }
rcSlaLatestRTTMax OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of RTT's that were successfully measured in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 7 }
rcSlaLatestRTTNumSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's probe
that were successfully measured from source to destination in latest test."
::= { rcSlaLatestEntry 8 }
rcSlaLatestRTTSumSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of RTT's delay
that were successfully measured from source to destination in latest test."
::= { rcSlaLatestEntry 9 }
rcSlaLatestRTTSumJitterSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's jitter that were successfully measured from source to destination in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 10 }
rcSlaLatestRTTSum2SD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured from source to destination in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 11 }
rcSlaLatestRTTMinSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of RTT's that were successfully measured from source to destination in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 12 }
rcSlaLatestRTTMaxSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of RTT's that were successfully measured from source to destination in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 13 }
rcSlaLatestRTTNumDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's probe
that were successfully measured from destination to source in latest test."
::= { rcSlaLatestEntry 14 }
rcSlaLatestRTTSumDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of RTT's delay
that were successfully measured from destination to source in latest test."
::= { rcSlaLatestEntry 15 }
rcSlaLatestRTTSumJitterDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's jitter that were successfully measured from destination to source in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 16 }
rcSlaLatestRTTSum2DS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured from destination to source in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 17 }
rcSlaLatestRTTMinDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of RTT's that were successfully measured from destination to source in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 18 }
rcSlaLatestRTTMaxDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of RTT's that were successfully measured from destination to source in latest test.
This object is applicable to 'Jitter' operation only."
::= { rcSlaLatestEntry 19 }
-- rcSlaStatisticTable
--
rcSlaStatisticTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 'SlaStatistic' statistics table contains summarized
information of the results for a conceptual control row."
::= { rcSlaScheduleGroup 2 }
rcSlaStatisticEntry OBJECT-TYPE
SYNTAX RcSlaStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains the objects which accumulate the
results of a series of 'Jitter' operations over a time
period stored in rcSlaConfigScheduleLife.
An entry is created only when the operation has been set and scheduled.
The entry will start to collect data when rcSlaConfigScheduleStatus
is in 'active' state. The entry will stop to collect data when the
rcSlaConfigScheduleStatus is changed to 'complete' state.
"
INDEX { rcSlaConfigOperId,
rcSlaStatisticStartTime
}
::={ rcSlaStatisticTable 1 }
RcSlaStatisticEntry ::= SEQUENCE {
rcSlaStatisticStartTime TimeStamp,
rcSlaStatisticScheduleLife Unsigned32,
rcSlaStatisticSchedulePeriod Unsigned32,
rcSlaStatisticTXNum Counter32,
rcSlaStatisticRTTNum Counter32,
rcSlaStatisticRTTSums Counter32,
rcSlaStatisticRTTSumJitter Counter32,
rcSlaStatisticRTTSum2L Counter32,
rcSlaStatisticRTTSum2H Counter32,
rcSlaStatisticRTTMin Gauge32,
rcSlaStatisticRTTMax Gauge32,
rcSlaStatisticRTTNumSD Counter32,
rcSlaStatisticRTTSumsSD Counter32,
rcSlaStatisticRTTSumJitterSD Counter32,
rcSlaStatisticRTTSum2LSD Counter32,
rcSlaStatisticRTTSum2HSD Counter32,
rcSlaStatisticRTTMinSD Gauge32,
rcSlaStatisticRTTMaxSD Gauge32,
rcSlaStatisticRTTNumDS Counter32,
rcSlaStatisticRTTSumsDS Counter32,
rcSlaStatisticRTTSumJitterDS Counter32,
rcSlaStatisticRTTSum2LDS Counter32,
rcSlaStatisticRTTSum2HDS Counter32,
rcSlaStatisticRTTMinDS Gauge32,
rcSlaStatisticRTTMaxDS Gauge32
}
rcSlaStatisticStartTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the time when the operation starts to be scheduled."
::= { rcSlaStatisticEntry 1 }
rcSlaStatisticScheduleLife OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the time duration over the whole schedule process. "
::= { rcSlaStatisticEntry 2 }
rcSlaStatisticSchedulePeriod OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's probe that were successfully measured in schedule."
::= { rcSlaStatisticEntry 3 }
rcSlaStatisticTXNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the duration between two SLA test
which includes all of probes schedule process in test. "
::= { rcSlaStatisticEntry 4 }
rcSlaStatisticRTTNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the duration between two SLA test
which includes all successful probes schedule process in test.
Take above example, if all of the rcSlaConfigSchedulePeriod of three operations are set to 60,
then the start time of each test of SLA operation like:
start time: T+0 -------- T+9 ---------- T+19-----
operation1 operation2 operation3
start again: T+60-------- T+69 ---------- T+79--
operation1 operation2 operation3
start 3rd time:T+120-------- T+129 ----------T+139--
operation1 operation2 operation3"
::= { rcSlaStatisticEntry 5 }
rcSlaStatisticRTTSums OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of RTT's delay that were successfully measured in schedule."
::= { rcSlaStatisticEntry 6 }
rcSlaStatisticRTTSumJitter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's jitter that were successfully measured in Schedule.
This object is applicable to 'Jitter' operation only."
::= { rcSlaStatisticEntry 7 }
rcSlaStatisticRTTSum2L OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured in Schedule.
This object is applicable to 'Jitter' operation only. (low order 32 bits)"
::= { rcSlaStatisticEntry 8 }
rcSlaStatisticRTTSum2H OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured in Schedule.
This object is applicable to 'Jitter' operation only. (high order 32 bits)"
::= { rcSlaStatisticEntry 9 }
rcSlaStatisticRTTMin OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of RTT's that were successfully measured in Schedule.
This object is applicable to 'Jitter' operation only."
::= { rcSlaStatisticEntry 10 }
rcSlaStatisticRTTMax OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of RTT's that were successfully measured in Schedule.
This object is applicable to 'Jitter' operation only."
::= { rcSlaStatisticEntry 11 }
rcSlaStatisticRTTNumSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's probe
that were successfully measured from source to destination in Schedule."
::= { rcSlaStatisticEntry 12 }
rcSlaStatisticRTTSumsSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of RTT's delay
that were successfully measured from source to destination in Schedule."
::= { rcSlaStatisticEntry 13 }
rcSlaStatisticRTTSumJitterSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's jitter that were successfully measured from source to destination in Schedule.
This object is applicable to 'Jitter' operation only."
::= { rcSlaStatisticEntry 14 }
rcSlaStatisticRTTSum2LSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured from source to destination in Schedule.
This object is applicable to 'Jitter' operation only. (low order 32 bits)"
::= { rcSlaStatisticEntry 15 }
rcSlaStatisticRTTSum2HSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured from source to destination in Schedule.
This object is applicable to 'Jitter' operation only. (high order 32 bits)"
::= { rcSlaStatisticEntry 16 }
rcSlaStatisticRTTMinSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of RTT's that were successfully measured from source to destination in Schedule.
This object is applicable to 'Jitter' operation only."
::= { rcSlaStatisticEntry 17 }
rcSlaStatisticRTTMaxSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of RTT's that were successfully measured from source to destination in Schedule.
This object is applicable to 'Jitter' operation only."
::= { rcSlaStatisticEntry 18 }
rcSlaStatisticRTTNumDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's probe
that were successfully measured from destination to source in Schedule."
::= { rcSlaStatisticEntry 19 }
rcSlaStatisticRTTSumsDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of RTT's delay
that were successfully measured from destination to source in Schedule."
::= { rcSlaStatisticEntry 20 }
rcSlaStatisticRTTSumJitterDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of RTT's jitter that were successfully measured from destination to source in Schedule.
This object is applicable to 'Jitter' operation only."
::= { rcSlaStatisticEntry 21 }
rcSlaStatisticRTTSum2LDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured from destination to source in Schedule.
This object is applicable to 'Jitter' operation only. (low order 32 bits)"
::= { rcSlaStatisticEntry 22 }
rcSlaStatisticRTTSum2HDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of squares of RTT's delay that are successfully measured from destination to source in Schedule.
This object is applicable to 'Jitter' operation only. (hige order 32 bits)"
::= { rcSlaStatisticEntry 23 }
rcSlaStatisticRTTMinDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of RTT's that were successfully measured from destination to source in Schedule.
This object is applicable to 'Jitter' operation only. "
::= { rcSlaStatisticEntry 24 }
rcSlaStatisticRTTMaxDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of RTT's that were successfully measured from destination to source in Schedule.
This object is applicable to 'Jitter' operation only."
::= { rcSlaStatisticEntry 25 }
-- rcSlaPktlmLatestTable
--
rcSlaPktlmLatestTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaPktlmLatestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the statistics calculated for the
latest sent frames."
::= { rcSlaScheduleGroup 3 }
rcSlaPktlmLatestEntry OBJECT-TYPE
SYNTAX RcSlaPktlmLatestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects that record the latest operation.
An entry is created only when the operation has been set and scheduled.
The entry will start to collect data when rcSlaConfigScheduleStatus
is in 'active' state. The entry will be removed when the
rcSlaConfigScheduleStatus is changed to 'complete' state. "
INDEX { rcSlaConfigOperId }
::={ rcSlaPktlmLatestTable 1 }
RcSlaPktlmLatestEntry ::= SEQUENCE {
rcSlaLatestPktlmTXNum Gauge32,
rcSlaLatestPktlmNum Gauge32,
rcSlaLatestPktlmSum Gauge32,
rcSlaLatestPktlmMin Gauge32,
rcSlaLatestPktlmMax Gauge32,
rcSlaLatestPktlmNumSD Gauge32,
rcSlaLatestPktlmSumSD Gauge32,
rcSlaLatestPktlmMinSD Gauge32,
rcSlaLatestPktlmMaxSD Gauge32,
rcSlaLatestPktlmNumDS Gauge32,
rcSlaLatestPktlmSumDS Gauge32,
rcSlaLatestPktlmMinDS Gauge32,
rcSlaLatestPktlmMaxDS Gauge32,
rcSlaLatestPktlmInterSumSD Gauge32,
rcSlaLatestPktlmInterSumDS Gauge32
}
rcSlaLatestPktlmTXNum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of packet loss measurement sent in latest test."
::= { rcSlaPktlmLatestEntry 1 }
rcSlaLatestPktlmNum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of packet loss measurement probe that were successfully measured in latest test."
::= { rcSlaPktlmLatestEntry 2 }
rcSlaLatestPktlmSum OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of packet loss measurement that were successfully measured in latest test."
::= { rcSlaPktlmLatestEntry 3 }
rcSlaLatestPktlmMin OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of packet loss measurement that were successfully measured in latest test."
::= { rcSlaPktlmLatestEntry 4 }
rcSlaLatestPktlmMax OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of packet loss measurement that were successfully measured in latest test."
::= { rcSlaPktlmLatestEntry 5 }
rcSlaLatestPktlmNumSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of packet loss measurement that were successfully measured from source to destination in latest test."
::= { rcSlaPktlmLatestEntry 6 }
rcSlaLatestPktlmSumSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of packet loss measurement that were successfully measured from source to destination in latest test."
::= { rcSlaPktlmLatestEntry 7 }
rcSlaLatestPktlmMinSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of packet loss measurement that were successfully measured from source to destination in latest test."
::= { rcSlaPktlmLatestEntry 8 }
rcSlaLatestPktlmMaxSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of packet loss measurement that were successfully measured from source to destination in latest test."
::= { rcSlaPktlmLatestEntry 9 }
rcSlaLatestPktlmNumDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of packet loss measurement that were successfully measured from destination to source in latest test."
::= { rcSlaPktlmLatestEntry 10 }
rcSlaLatestPktlmSumDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of packet loss measurement that were successfully measured from destination to source in latest test."
::= { rcSlaPktlmLatestEntry 11 }
rcSlaLatestPktlmMinDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of packet loss measurement that were successfully measured from destination to source in latest test."
::= { rcSlaPktlmLatestEntry 12 }
rcSlaLatestPktlmMaxDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of packet loss measurement that were successfully measured from destination to source in latest test."
::= { rcSlaPktlmLatestEntry 13 }
rcSlaLatestPktlmInterSumSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of packet loss measurement that were successfully measured from destination to source in interval time test."
::= { rcSlaPktlmLatestEntry 14 }
rcSlaLatestPktlmInterSumDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of packet loss measurement that were successfully measured from destination to source in interval time test."
::= { rcSlaPktlmLatestEntry 15 }
-- rcSlaPktlmStatisticTable
--
rcSlaPktlmStatisticTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaPktlmStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 'SlaPktlmStatistic' statistics table contains summarized
information of the results for a conceptual control row."
::= { rcSlaScheduleGroup 4 }
rcSlaPktlmStatisticEntry OBJECT-TYPE
SYNTAX RcSlaPktlmStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry is created only when the operation has been set and scheduled.
The entry will start to collect data when rcSlaConfigScheduleStatus
is in 'active' state. The entry will stop to collect data when the
rcSlaConfigScheduleStatus is changed to 'complete' state.
"
INDEX { rcSlaConfigOperId,
rcSlaStatisticPktlmStartTime
}
::={ rcSlaPktlmStatisticTable 1 }
RcSlaPktlmStatisticEntry ::= SEQUENCE {
rcSlaStatisticPktlmStartTime TimeStamp,
rcSlaStatisticPktlmScheduleLife Unsigned32,
rcSlaStatisticPktlmSchedulePeriod Unsigned32,
rcSlaStatisticPktlmTXNum Counter32,
rcSlaStatisticPktlmNum Counter32,
rcSlaStatisticPktlmSums Counter32,
rcSlaStatisticPktlmMin Gauge32,
rcSlaStatisticPktlmMax Gauge32,
rcSlaStatistiPktlmNumSD Counter32,
rcSlaStatisticPktlmSumsSD Counter32,
rcSlaStatisticPktlmMinSD Gauge32,
rcSlaStatisticPktlmMaxSD Gauge32,
rcSlaStatisticPktlmNumDS Counter32,
rcSlaStatisticPktlmSumsDS Counter32,
rcSlaStatisticPktlmMinDS Gauge32,
rcSlaStatisticPktlmMaxDS Gauge32
}
rcSlaStatisticPktlmStartTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the time when the operation starts to be scheduled."
::= { rcSlaPktlmStatisticEntry 1 }
rcSlaStatisticPktlmScheduleLife OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the time duration over the whole schedule process. "
::= { rcSlaPktlmStatisticEntry 2 }
rcSlaStatisticPktlmSchedulePeriod OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of packet loss measurement probe that were successfully measured in schedule."
::= { rcSlaPktlmStatisticEntry 3 }
rcSlaStatisticPktlmTXNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the duration between two SLA test
which includes all of probes schedule process in test. "
::= { rcSlaPktlmStatisticEntry 4 }
rcSlaStatisticPktlmNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the duration between two SLA test
which includes all successful probes schedule process in test.
Take above example, if all of the rcSlaConfigSchedulePeriod of three operations are set to 60,
then the start time of each test of SLA operation like:
start time: T+0 -------- T+9 ---------- T+19-----
operation1 operation2 operation3
start again: T+60-------- T+69 ---------- T+79--
operation1 operation2 operation3
start 3rd time:T+120-------- T+129 ----------T+139--
operation1 operation2 operation3"
::= { rcSlaPktlmStatisticEntry 5 }
rcSlaStatisticPktlmSums OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of packet loss measurement that were successfully measured in schedule."
::= { rcSlaPktlmStatisticEntry 6 }
rcSlaStatisticPktlmMin OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of packet loss measurement that were successfully measured in Schedule."
::= { rcSlaPktlmStatisticEntry 7 }
rcSlaStatisticPktlmMax OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of packet loss measurement that were successfully measured in Schedule. "
::= { rcSlaPktlmStatisticEntry 8 }
rcSlaStatistiPktlmNumSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of packet loss measurement
that were successfully measured from source to destination in Schedule."
::= { rcSlaPktlmStatisticEntry 9 }
rcSlaStatisticPktlmSumsSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of packet loss measurement
that were successfully measured from source to destination in Schedule."
::= { rcSlaPktlmStatisticEntry 10 }
rcSlaStatisticPktlmMinSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of packet loss measurement that were successfully measured from source to destination in Schedule. "
::= { rcSlaPktlmStatisticEntry 11 }
rcSlaStatisticPktlmMaxSD OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of packet loss measurement that were successfully measured from source to destination in Schedule. "
::= { rcSlaPktlmStatisticEntry 12 }
rcSlaStatisticPktlmNumDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of packet loss measurement
that were successfully measured from destination to source in Schedule."
::= { rcSlaPktlmStatisticEntry 13 }
rcSlaStatisticPktlmSumsDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the sum of packet loss measurement
that were successfully measured from destination to source in Schedule."
::= { rcSlaPktlmStatisticEntry 14 }
rcSlaStatisticPktlmMinDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the minimum of packet loss measurement that were successfully measured from destination to source in Schedule. "
::= { rcSlaPktlmStatisticEntry 15 }
rcSlaStatisticPktlmMaxDS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the maximum of packet loss measurement that were successfully measured from destination to source in Schedule."
::= { rcSlaPktlmStatisticEntry 16 }
--rcSlaThroughputGroup --
--rcSlaThroughputGroup
--rcSlaCThroughputConfigTable
--rcSlaThroughputConfigEntry
--rcSlaThroughputIndex
--rcSlaThroughputOperId
--rcSlaThroughputObject
--rcSlaThroughputPktLength
--rcSlaThroughputCount
--rcSlaThroughputDuration
--rcSlaThroughputEnable
--rcSlaThroughputStatus
--rcSlaThroughputRowStatus
--rcSlaThroughputCompleteNum
--rcSlaThroughputMeasureStartTime
--rcSlaThroughputMeasureLastTime
--rcSlaThroughputMeasureEndTime
--rcSlaThroughputFailedNum
--rcSlaCThroughputResultTable
--rcSlaThroughputResultEntry
--rcSlaThroughputResultId
--rcSlaThroughputCfgId
--rcSlaThroughputStartTime
--rcSlaThroughputEndTime
--rcSlaThroughputLastTime
--rcSlaThroughputLocalSendPStatics
--rcSlaThroughputLocalSendBStatics
--rcSlaThroughputLocalReceivePStatics
--rcSlaThroughputLocalReceiveBStatics
--rcSlaThroughputRemoteSendPStatics
--rcSlaThroughputRemoteSendBStatics
--rcSlaThroughputRemoteReceivePStatics
--rcSlaThroughputRemoteReceiveBStatics
rcSlaThroughputConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaThroughputConfigEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains sla control data."
::= { rcSlaThroughputGroup 1 }
rcSlaThroughputConfigEntry OBJECT-TYPE
SYNTAX RcSlaThroughputConfigEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A collection of objects that define three conceptual
control row : slaY.1731EntryTable, slaIcmpEntryTable, slaSchEntryTable.
The 'slaY.1731EntryTable' is used to control y1731 operation .
The following objects must be specified in order to create this
conceptual row.
- rcSlaConfigOperType
- rcSlaConfigVlanId
- rcSlaConfigMDLevel
- rcSlaConfigDestMacAddr
- rcSlaConfigRMepId
The ' slaIcmpEntryTable' is used to control ICMP operation .
The following objects must be specified in order to create this
conceptual row.
- rcSlaConfigOperType
- rcSlaConfigDestIpAddr
The ' slaIcmpSchTable' is used to control operation schduled."
INDEX { rcSlaThroughputIndex }
::={ rcSlaThroughputConfigTable 1 }
RcSlaThroughputConfigEntry ::= SEQUENCE {
rcSlaThroughputIndex Unsigned32 (0..100 ),
rcSlaThroughputOperId Unsigned32,
rcSlaThroughputObject Unsigned32 (125..1000000),
rcSlaThroughputPktLength INTEGER,
rcSlaThroughputCount Unsigned32,
rcSlaThroughputDuration Unsigned32,
rcSlaThroughputEnable TruthValue,
rcSlaThroughputStatus INTEGER,
rcSlaThroughputFailedNum Unsigned32,
rcSlaThroughputCompleteNum Unsigned32,
rcSlaThroughputMeasureStartTime Unsigned32,
rcSlaThroughputMeasureLastTime Unsigned32,
rcSlaThroughputMeasureEndTime Unsigned32,
rcSlaThroughputRowStatus RowStatus
}
rcSlaThroughputIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..100 )
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 1 }
rcSlaThroughputOperId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 2 }
rcSlaThroughputObject OBJECT-TYPE
SYNTAX Unsigned32 (125..1000000)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 3 }
rcSlaThroughputPktLength OBJECT-TYPE
SYNTAX INTEGER{
length64 (0),
length128 (1),
length256 (2),
length512 (3),
length1024 (4),
length1280 (5),
length1518 (6)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 4 }
rcSlaThroughputCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 5 }
rcSlaThroughputDuration OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 6 }
rcSlaThroughputEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 7 }
rcSlaThroughputStatus OBJECT-TYPE
SYNTAX INTEGER {
throughput-init (1),
throughput-Active (2),
throughput-Complete (3),
throughput-Disturb (4)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 8 }
rcSlaThroughputCompleteNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 9 }
rcSlaThroughputFailedNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 10 }
rcSlaThroughputMeasureStartTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 11 }
rcSlaThroughputMeasureEndTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 12 }
rcSlaThroughputMeasureLastTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 13 }
rcSlaThroughputRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputConfigEntry 14 }
rcSlaThroughputResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaThroughputResultEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains sla control data."
::= { rcSlaThroughputGroup 2 }
rcSlaThroughputResultEntry OBJECT-TYPE
SYNTAX RcSlaThroughputResultEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A collection of objects that define three conceptual
control row : slaY.1731EntryTable, slaIcmpEntryTable, slaSchEntryTable.
The 'slaY.1731EntryTable' is used to control y1731 operation .
The following objects must be specified in order to create this
conceptual row.
- rcSlaConfigOperType
- rcSlaConfigVlanId
- rcSlaConfigMDLevel
- rcSlaConfigDestMacAddr
- rcSlaConfigRMepId
The ' slaIcmpEntryTable' is used to control ICMP operation .
The following objects must be specified in order to create this
conceptual row.
- rcSlaConfigOperType
- rcSlaConfigDestIpAddr
The ' slaIcmpSchTable' is used to control operation schduled."
INDEX { rcSlaThroughputIndex,
rcSlaThroughputResultId }
::={ rcSlaThroughputResultTable 1 }
RcSlaThroughputResultEntry ::= SEQUENCE {
rcSlaThroughputResultId Unsigned32,
rcSlaThroughputTestStartTime Unsigned32,
rcSlaThroughputTestEndTime Unsigned32,
rcSlaThroughputTestLastTime Unsigned32,
rcSlaThroughputLocalSendPStatics Counter64,
rcSlaThroughputLocalSendBStatics Counter64,
rcSlaThroughputLocalReceivePStatics Counter64,
rcSlaThroughputLocalReceiveBStatics Counter64,
rcSlaThroughputRemoteSendPStatics Counter64,
rcSlaThroughputRemoteSendBStatics Counter64,
rcSlaThroughputRemoteReceivePStatics Counter64,
rcSlaThroughputRemoteReceiveBStatics Counter64
}
rcSlaThroughputResultId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 1 }
rcSlaThroughputTestStartTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 2 }
rcSlaThroughputTestEndTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 3 }
rcSlaThroughputTestLastTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 4 }
rcSlaThroughputLocalSendPStatics OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 5 }
rcSlaThroughputLocalSendBStatics OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 6 }
rcSlaThroughputLocalReceivePStatics OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 7 }
rcSlaThroughputLocalReceiveBStatics OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 8 }
rcSlaThroughputRemoteSendPStatics OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 9 }
rcSlaThroughputRemoteSendBStatics OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 10 }
rcSlaThroughputRemoteReceivePStatics OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 11 }
rcSlaThroughputRemoteReceiveBStatics OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates a row in the rcSlaConfigTable.
This value is an operation number configured by user."
::= { rcSlaThroughputResultEntry 12 }
rcSlaThroughputResultTrap NOTIFICATION-TYPE
OBJECTS { rcSlaThroughputResultId
}
STATUS deprecated
DESCRIPTION
""
::= { rcSlaThroughputGroup 4 }
---告警阈值表
rcSlaThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains sla trap threshold."
::= { rcSlaThresholdGroup 1 }
rcSlaThresholdEntry OBJECT-TYPE
SYNTAX RcSlaThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of rcSlaThresholdTable."
INDEX { rcSlaTrapOperId }
::={ rcSlaThresholdTable 1 }
RcSlaThresholdEntry ::= SEQUENCE {
rcSlaTrapOperId Unsigned32,
rcSlaTrapEnableType BITS,
rcSlaPktLossRateCurrThreshold INTEGER,
rcSlaPktLossRateAverThreshold INTEGER,
rcSlaDelayCurrThreshold Counter32,
rcSlaDelayCurrThresholdSD Counter32,
rcSlaDelayCurrThresholdDS Counter32,
rcSlaDelayAverThreshold Counter32,
rcSlaDelayAverThresholdSD Counter32,
rcSlaDelayAverThresholdDS Counter32,
rcSlaJitterCurrThreshold Counter32,
rcSlaJitterCurrThresholdSD Counter32,
rcSlaJitterCurrThresholdDS Counter32,
rcSlaJitterAverThreshold Counter32,
rcSlaJitterAverThresholdSD Counter32,
rcSlaJitterAverThresholdDS Counter32
}
rcSlaTrapOperId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a row in the rcSlaThresholdTable.
This value is an operation number configured by user."
::= { rcSlaThresholdEntry 1 }
rcSlaTrapEnableType OBJECT-TYPE
SYNTAX BITS
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The enable status of threshold trap."
::= { rcSlaThresholdEntry 2 }
rcSlaPktLossRateCurrThreshold OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The pkt loss rate threshold of the last test."
::= { rcSlaThresholdEntry 3 }
rcSlaPktLossRateAverThreshold OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The average pkt loss rate threshold of all test."
::= { rcSlaThresholdEntry 4 }
rcSlaDelayCurrThreshold OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RTT delay threshold of the last test."
::= { rcSlaThresholdEntry 5 }
rcSlaDelayCurrThresholdSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay threshold of the last test from source to destination."
::= { rcSlaThresholdEntry 6 }
rcSlaDelayCurrThresholdDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay threshold of the last test from destination to source."
::= { rcSlaThresholdEntry 7 }
rcSlaDelayAverThreshold OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RTT average delay threshold of all test."
::= { rcSlaThresholdEntry 8 }
rcSlaDelayAverThresholdSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The average delay threshold of all test from source to destination."
::= { rcSlaThresholdEntry 9 }
rcSlaDelayAverThresholdDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The average delay threshold of all test from destination to source."
::= { rcSlaThresholdEntry 10 }
rcSlaJitterCurrThreshold OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RTT jitter threshold of the last test."
::= { rcSlaThresholdEntry 11 }
rcSlaJitterCurrThresholdSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The jitter threshold of the last test from source to destination."
::= { rcSlaThresholdEntry 12 }
rcSlaJitterCurrThresholdDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The jitter threshold of the last test from destination to source."
::= { rcSlaThresholdEntry 13 }
rcSlaJitterAverThreshold OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RTT average jitter threshold of all test."
::= { rcSlaThresholdEntry 14 }
rcSlaJitterAverThresholdSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The average jitter threshold of all test from source to destination."
::= { rcSlaThresholdEntry 15 }
rcSlaJitterAverThresholdDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The average jitter threshold of all test from destination to source."
::= { rcSlaThresholdEntry 16 }
---告警信息表
rcSlaThresholdTestResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaThresholdTestResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains sla test result."
::= { rcSlaThresholdGroup 2 }
rcSlaThresholdTestResultEntry OBJECT-TYPE
SYNTAX RcSlaThresholdTestResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of rcSlaThresholdTestResultTable."
INDEX { rcSlaTrapOperId }
::={ rcSlaThresholdTestResultTable 1 }
RcSlaThresholdTestResultEntry ::= SEQUENCE {
rcSlaCurrResultTrap BITS,
rcSlaAverResultTrap BITS,
rcSlaPktCurrLossRate INTEGER,
rcSlaPktAverLossRate INTEGER,
rcSlaCurrDelay Counter32,
rcSlaCurrDelaySD Counter32,
rcSlaCurrDelayDS Counter32,
rcSlaAverDelay Counter32,
rcSlaAverDelaySD Counter32,
rcSlaAverDelayDS Counter32,
rcSlaCurrJitter Counter32,
rcSlaCurrJitterSD Counter32,
rcSlaCurrJitterDS Counter32,
rcSlaAverJitter Counter32,
rcSlaAverJitterSD Counter32,
rcSlaAverJitterDS Counter32
}
rcSlaCurrResultTrap OBJECT-TYPE
SYNTAX BITS
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sla result trap status of the last test."
::= { rcSlaThresholdTestResultEntry 1 }
rcSlaAverResultTrap OBJECT-TYPE
SYNTAX BITS
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sla average result trap status of all test."
::= { rcSlaThresholdTestResultEntry 2 }
rcSlaPktCurrLossRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The pkt loss rate of the last test."
::= { rcSlaThresholdTestResultEntry 3 }
rcSlaPktAverLossRate OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average pkt loss rate of all test."
::= { rcSlaThresholdTestResultEntry 4 }
rcSlaCurrDelay OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RTT delay of the last test."
::= { rcSlaThresholdTestResultEntry 5 }
rcSlaCurrDelaySD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The delay of the last test from source to destination."
::= { rcSlaThresholdTestResultEntry 6 }
rcSlaCurrDelayDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The delay of the last test from destination to source."
::= { rcSlaThresholdTestResultEntry 7 }
rcSlaAverDelay OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RTT average delay of all test."
::= { rcSlaThresholdTestResultEntry 8 }
rcSlaAverDelaySD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average delay of all test from source to destination."
::= { rcSlaThresholdTestResultEntry 9 }
rcSlaAverDelayDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average delay of all test from destination to source."
::= { rcSlaThresholdTestResultEntry 10 }
rcSlaCurrJitter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RTT jitter of the last test."
::= { rcSlaThresholdTestResultEntry 11 }
rcSlaCurrJitterSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The jitter of the last test from source to destination."
::= { rcSlaThresholdTestResultEntry 12 }
rcSlaCurrJitterDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The jitter of the last test from destination to source."
::= { rcSlaThresholdTestResultEntry 13 }
rcSlaAverJitter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RTT average jitter of all test."
::= { rcSlaThresholdTestResultEntry 14 }
rcSlaAverJitterSD OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average jitter of all test from source to destination."
::= { rcSlaThresholdTestResultEntry 15 }
rcSlaAverJitterDS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average jitter of all test from destination to source."
::= { rcSlaThresholdTestResultEntry 16 }
--阈值告警
rcSlaThresholdTrapGroup OBJECT IDENTIFIER ::= {rcSlaThresholdGroup 3}
rcSlaCurrTestResultBeyondTrap NOTIFICATION-TYPE
OBJECTS { rcSlaCurrResultTrap,
rcSlaPktCurrLossRate,
rcSlaPktLossRateCurrThreshold,
rcSlaCurrDelay,
rcSlaDelayCurrThreshold,
rcSlaCurrDelaySD,
rcSlaDelayCurrThresholdSD,
rcSlaCurrDelayDS,
rcSlaDelayCurrThresholdDS,
rcSlaCurrJitter,
rcSlaJitterCurrThreshold,
rcSlaCurrJitterSD,
rcSlaJitterCurrThresholdSD,
rcSlaCurrJitterDS,
rcSlaJitterCurrThresholdDS
}
STATUS current
DESCRIPTION
"Send this trap when result beyond threshold of the last test."
::= { rcSlaThresholdTrapGroup 1 }
rcSlaAverTestResultBeyondTrap NOTIFICATION-TYPE
OBJECTS { rcSlaAverResultTrap,
rcSlaPktAverLossRate,
rcSlaPktLossRateAverThreshold,
rcSlaAverDelay,
rcSlaDelayAverThreshold,
rcSlaAverDelaySD,
rcSlaDelayAverThresholdSD,
rcSlaAverDelayDS,
rcSlaDelayAverThresholdDS,
rcSlaAverJitter,
rcSlaJitterAverThreshold,
rcSlaAverJitterSD,
rcSlaJitterAverThresholdSD,
rcSlaAverJitterDS,
rcSlaJitterAverThresholdDS
}
STATUS current
DESCRIPTION
"Send this trap when average result beyond threshold of all test."
::= { rcSlaThresholdTrapGroup 2 }
--********************************************
--LM last measurement interval information
--********************************************
rcmefSoamLmLastStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcmefSoamLmLastStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the results for last Measurement
Intervals in a SOAM Loss Measurement session.
Rows of this table object are created automatically
by the SNMP Agent when the Loss Measurement session is running and a
Measurement Interval is completed.
The rows and objects in this table are to be persistent upon reboot
or restart of a device.
"
::= { rcmefSoamLastStatsGroup 1 }
rcmefSoamLmLastStatsEntry OBJECT-TYPE
SYNTAX RcmefSoamLmLastStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of mefSoamLmHistoryStatsTable"
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
rcSlaConfigOperId
}
::= { rcmefSoamLmLastStatsTable 1 }
RcmefSoamLmLastStatsEntry ::= SEQUENCE {
rcmefSoamPmLastForwardFlr Unsigned32,
rcmefSoamPmLastBackwardFlr Unsigned32,
rcmefSoamPmLastForwardAvailability Unsigned32,
rcmefSoamPmLastBackwardAvailability Unsigned32,
rcmefSoamPmLastTwoWayAvailability Unsigned32,
rcmefSoamPmLastIngressBandwidth Counter64
}
rcmefSoamPmLastForwardFlr OBJECT-TYPE
SYNTAX Unsigned32 (0..100000)
UNITS "milli-percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the Last frame loss ratio in the
forward direction calculated by this MEP. The FLR value
is a ratio that is expressed as a percent with a value of 0
(ratio 0.00) through 100000 (ratio 1.00).
Units are in milli-percent, where 1 indicates 0.001 percent.
"
::= { rcmefSoamLmLastStatsEntry 1 }
rcmefSoamPmLastBackwardFlr OBJECT-TYPE
SYNTAX Unsigned32 (0..100000)
UNITS "milli-percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the Last frame loss ratio in the
Backward direction calculated by this MEP. The FLR value
is a ratio that is expressed as a percent with a value of 0
(ratio 0.00) through 100000 (ratio 1.00).
Units are in milli-percent, where 1 indicates 0.001 percent.
"
::= { rcmefSoamLmLastStatsEntry 2 }
rcmefSoamPmLastForwardAvailability OBJECT-TYPE
SYNTAX Unsigned32 (0..100000)
UNITS "milli-percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Availability /total time.
"
::= { rcmefSoamLmLastStatsEntry 3 }
rcmefSoamPmLastBackwardAvailability OBJECT-TYPE
SYNTAX Unsigned32 (0..100000)
UNITS "milli-percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Availability /total time.
"
::= { rcmefSoamLmLastStatsEntry 4 }
rcmefSoamPmLastTwoWayAvailability OBJECT-TYPE
SYNTAX Unsigned32 (0..100000)
UNITS "milli-percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Availability /total time.
"
::= { rcmefSoamLmLastStatsEntry 5 }
rcmefSoamPmLastIngressBandwidth OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the Last Ingress bandwith.
"
::= { rcmefSoamLmLastStatsEntry 6 }
--********************************************
--DM last measurement interval information
--********************************************
rcmefSoamDmLastStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcmefSoamDmLastStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the results for last Measurement
Intervals in a SOAM Loss Measurement session.
Rows of this table object are created automatically
by the SNMP Agent when the Loss Measurement session is running and a
Measurement Interval is completed.
The rows and objects in this table are to be persistent upon reboot
or restart of a device.
"
::= { rcmefSoamLastStatsGroup 2 }
rcmefSoamDmLastStatsEntry OBJECT-TYPE
SYNTAX RcmefSoamDmLastStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of mefSoamLmHistoryStatsTable"
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
rcSlaConfigOperId
}
::= { rcmefSoamDmLastStatsTable 1 }
RcmefSoamDmLastStatsEntry ::= SEQUENCE {
rcmefSoamPmLastFrameDelayTwoWay Unsigned32,
rcmefSoamPmLastIfdvTwoWay Unsigned32
}
rcmefSoamPmLastFrameDelayTwoWay OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the Last frame delay
in the twoway direction calculated by this MEP.
"
::= { rcmefSoamDmLastStatsEntry 1 }
rcmefSoamPmLastIfdvTwoWay OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the Last inter-frame delay variation
in the twoway direction calculated by this MEP.
"
::= { rcmefSoamDmLastStatsEntry 2 }
--rcSlaMaintenanceGroup
rcSlaMaintenanceEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance interval switch"
DEFVAL { false }
::= { rcSlaMaintenanceGroup 1 }
--rcSlaThresholdProfileGroup
--------------------------------------------------------------------------------------
--rcSlaThresholdProfileTable
--------------------------------------------------------------------------------------
rcSlaThresholdProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaThresholdProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains sla Threshold data."
::= { rcSlaThresholdProfileGroup 1 }
rcSlaThresholdProfileEntry OBJECT-TYPE
SYNTAX RcSlaThresholdProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about the profile. This table will create
a profile which only contains its description, the
Threshold of each Profile is defined in the associated
table rcSlaThresholdCfgTable."
INDEX { rcSlaThresholdProfileIndex }
::={ rcSlaThresholdProfileTable 1 }
RcSlaThresholdProfileEntry ::= SEQUENCE {
rcSlaThresholdProfileIndex Unsigned32(1..16),
rcSlaThresholdProfileDescription OCTET STRING (SIZE(0..32)),
rcSlaThresholdProfileRef Gauge32,
rcSlaThresholdProfileStatus RowStatus
}
rcSlaThresholdProfileIndex OBJECT-TYPE
SYNTAX Unsigned32(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the sla
profile table."
::= { rcSlaThresholdProfileEntry 1 }
rcSlaThresholdProfileDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies description of profile."
::= { rcSlaThresholdProfileEntry 2 }
rcSlaThresholdProfileRef OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value descrides how many times the profile is in use."
::= { rcSlaThresholdProfileEntry 3 }
rcSlaThresholdProfileStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"the status of rcSlaThresholdProfileTable
This value is an operation number configured by user"
::= { rcSlaThresholdProfileEntry 4 }
--------------------------------------------------------------------------------------
--rcSlaThresholdCfgTable
--------------------------------------------------------------------------------------
rcSlaThresholdCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlaThresholdCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about the profile"
::= { rcSlaThresholdProfileGroup 2 }
rcSlaThresholdCfgEntry OBJECT-TYPE
SYNTAX RcSlaThresholdCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about types of disposal of given protocols. The
entries will be on a per profile, per protocol basis."
INDEX {
rcSlaThresholdProfileIndex,
rcServiceCosLabel
}
::= { rcSlaThresholdCfgTable 1 }
RcSlaThresholdCfgEntry ::= SEQUENCE {
rcSlaThresholdCfgFd Unsigned32 ,
rcSlaThresholdCfgIfdv Unsigned32,
rcSlaThresholdCfgFlr Unsigned32,
rcSlaThresholdCfgAvailbility Unsigned32
}
rcSlaThresholdCfgFd OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Sla Frame delay Threshold"
::= { rcSlaThresholdCfgEntry 1 }
rcSlaThresholdCfgIfdv OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Ifdv Threshold "
::= { rcSlaThresholdCfgEntry 2 }
rcSlaThresholdCfgFlr OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milli-percent"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Flr Threshold ."
::= { rcSlaThresholdCfgEntry 3 }
rcSlaThresholdCfgAvailbility OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milli-percent"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Availbility Threshold ."
::= { rcSlaThresholdCfgEntry 4 }
END