-- file :a2002nv3.pkb
|
|
--
|
|
ACE2002-MIB
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
--Title: ACE2002 MIB
|
|
|
|
-- Copyright 2201 RAD Data Communications, Ltd.
|
|
-- All Rights Reserved.
|
|
|
|
-- It is RAD's intent to encourage the widespread use of
|
|
-- this Specification in connection with the management of
|
|
-- RAD products. RAD grants vendors, end-users,
|
|
-- and other interested parties a non-exclusive license to
|
|
-- use this Specification in connection with the management
|
|
-- of RAD products.
|
|
|
|
-- This Specification is supplied "as is," and RAD makes
|
|
-- no warranty, either express or implied, as to the use,
|
|
-- operation, condition, or performance of the Specification.
|
|
|
|
IMPORTS
|
|
TimeTicks,enterprises,
|
|
IpAddress, OBJECT-TYPE, Integer32,
|
|
Counter32, Gauge32, OBJECT-IDENTITY,
|
|
NOTIFICATION-TYPE, Counter64,Unsigned32 FROM SNMPv2-SMI
|
|
PerfCurrentCount,
|
|
PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB
|
|
InterfaceIndex, ifAlias, ifIndex FROM IF-MIB
|
|
dsx1LineStatus,
|
|
dsx1LineStatusLastChange,
|
|
dsx1CurrentIndex, dsx1LineIndex,
|
|
dsx1IntervalIndex, dsx1IntervalNumber,
|
|
dsx1LoopbackStatus,
|
|
dsx1TotalIndex FROM DS1-MIB
|
|
imaGroupIndex, imaLinkIfIndex,
|
|
imaGroupFailureStatus FROM IMA-MIB
|
|
RowStatus, DisplayString, TimeStamp,
|
|
DateAndTime, TruthValue FROM SNMPv2-TC
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
frAtmIwfConnectionEntry FROM FR-ATM-PVC-SERVICE-IWF-MIB
|
|
isdnSignalingEntry FROM ISDN-MIB
|
|
VlanIndex, PortList FROM Q-BRIDGE-MIB
|
|
dot1dBasePortEntry FROM BRIDGE-MIB
|
|
atmfCESConfEntry FROM ATMF-CES
|
|
atmVclEntry, aal5VccEntry,
|
|
aal5VccVpi, aal5VccVci,
|
|
atmVplVpi, atmVclVpi, atmVclVci,
|
|
atmVpCrossConnectEntry,
|
|
atmVcCrossConnectEntry,
|
|
atmVclEntry, aal5VccEntry FROM ATM-MIB
|
|
IANAifType FROM IANAifType-MIB
|
|
ipoaLisIfMappingEntry FROM IPOA-MIB ;
|
|
|
|
|
|
-- Some MIB compilers need those two lines:
|
|
-- enterprises OBJECT IDENTIFIER ::=
|
|
-- { iso org(3) dod(6) internet(1) private(4) 1 }
|
|
|
|
MacAddress ::= OCTET STRING (SIZE(6))
|
|
|
|
rad OBJECT IDENTIFIER ::= { enterprises 164 }
|
|
radTokenRing OBJECT IDENTIFIER ::= { rad 1 } -- RAD Token Ring tree
|
|
radFddi OBJECT IDENTIFIER ::= { rad 2 } -- rad FDDI Tree
|
|
radWan OBJECT IDENTIFIER ::= { rad 3 } -- rad WAN Tree
|
|
radBridges OBJECT IDENTIFIER ::= {rad 4 }
|
|
radConverters OBJECT IDENTIFIER ::= { rad 5 } -- RAD Converters products' tree
|
|
radGen OBJECT IDENTIFIER ::= { rad 6} -- General information
|
|
radStkHub OBJECT IDENTIFIER ::= { rad 7 } -- stackable products
|
|
radAtm OBJECT IDENTIFIER ::= { rad 12} -- stackable products
|
|
wanGen OBJECT IDENTIFIER ::= {radWan 1}
|
|
diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}
|
|
|
|
--atmNte OBJECT IDENTIFIER ::= { radAtm 3 }
|
|
--atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 }
|
|
--atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 }
|
|
--dacsMux OBJECT IDENTIFIER ::= {radWan 3}
|
|
--genDacsMux OBJECT IDENTIFIER ::= {dacsMux 4}
|
|
radRouter OBJECT IDENTIFIER ::= { rad 11 }
|
|
rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
|
|
radExperimental OBJECT IDENTIFIER ::= { rad 20 } -- Drafts that have no MIB tree yet
|
|
-- igmpStdMIB MODULE-IDENTITY ::= { radExperimental 1 }
|
|
-- apsMIB OBJECT IDENTIFIER ::= { radExperimental 2 }
|
|
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\radgen.txt
|
|
--
|
|
--Version: 5.00
|
|
--First Version Date: 25.01.99
|
|
--By: Orly Nicklass
|
|
--File: radgen.txt
|
|
|
|
--Last update: 09-Oct-2003 by Smadar Tauber
|
|
|
|
|
|
systems OBJECT IDENTIFIER ::= { radGen 1} -- list of RAD products
|
|
|
|
--agnt OBJECT IDENTIFIER ::= { radGen 2} agent general tree
|
|
|
|
--services OBJECT IDENTIFIER ::= { radGen 3} See services.txt
|
|
|
|
|
|
radSysTR OBJECT IDENTIFIER ::= { systems 1 } -- RAD Token Ring
|
|
|
|
radRADring OBJECT IDENTIFIER ::= { radSysTR 1 }
|
|
|
|
radTMA OBJECT IDENTIFIER ::= { radSysTR 2 }
|
|
|
|
radRingMonitor OBJECT IDENTIFIER ::= { radSysTR 3 }
|
|
|
|
radSysFddi OBJECT IDENTIFIER ::= { systems 2 } -- RAD Fddi
|
|
|
|
radFDX100 OBJECT IDENTIFIER ::= { radSysFddi 1 } -- RAD Fddi
|
|
|
|
radSysWan OBJECT IDENTIFIER ::= { systems 3 } -- RAD Wan products
|
|
|
|
radSysWanEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for RAD Wan products."
|
|
::= { radSysWan 0 }
|
|
|
|
radMP2100 OBJECT IDENTIFIER ::= { radSysWan 1 }
|
|
radMP2104 OBJECT IDENTIFIER ::= { radSysWan 2 }
|
|
radMP2100B OBJECT IDENTIFIER ::= { radSysWan 3 }
|
|
radMP2100F OBJECT IDENTIFIER ::= { radSysWan 4 }
|
|
|
|
radMP2100H OBJECT IDENTIFIER ::= { radSysWan 5 }
|
|
radMP2104H OBJECT IDENTIFIER ::= { radSysWan 6 }
|
|
radMP2200B OBJECT IDENTIFIER ::= { radSysWan 7 }
|
|
radMP2200F OBJECT IDENTIFIER ::= { radSysWan 8 }
|
|
|
|
radMX3000 OBJECT IDENTIFIER ::= { radSysWan 9 }
|
|
radMX3004 OBJECT IDENTIFIER ::= { radSysWan 10 }
|
|
radMX30 OBJECT IDENTIFIER ::= { radSysWan 11 }
|
|
radMX300 OBJECT IDENTIFIER ::= { radSysWan 12 }
|
|
|
|
radVOIP OBJECT IDENTIFIER ::= { radSysWan 13 }
|
|
|
|
radKM2100 OBJECT IDENTIFIER ::= { radSysWan 15 }
|
|
radKM2104 OBJECT IDENTIFIER ::= { radSysWan 16 }
|
|
|
|
radDXC30 OBJECT IDENTIFIER ::= { radSysWan 20 }
|
|
radDXC10A OBJECT IDENTIFIER ::= { radSysWan 21 }
|
|
radDXC8R OBJECT IDENTIFIER ::= { radSysWan 22 }
|
|
radDXC30E OBJECT IDENTIFIER ::= { radSysWan 23 }
|
|
radDXC3000 OBJECT IDENTIFIER ::= { radSysWan 24 }
|
|
radDXC8RNew OBJECT IDENTIFIER ::= { radSysWan 25 }
|
|
|
|
radFcdT1L OBJECT IDENTIFIER ::= { radSysWan 28 }
|
|
radFcdE1L OBJECT IDENTIFIER ::= { radSysWan 29 }
|
|
radFcdT1 OBJECT IDENTIFIER ::= { radSysWan 30 }
|
|
radFcdE1 OBJECT IDENTIFIER ::= { radSysWan 31 }
|
|
radFcdE1I OBJECT IDENTIFIER ::= { radSysWan 32 }
|
|
radFcdT1M OBJECT IDENTIFIER ::= { radSysWan 33 }
|
|
radFcdE1M OBJECT IDENTIFIER ::= { radSysWan 34 }
|
|
radFcdIP OBJECT IDENTIFIER ::= { radSysWan 35}
|
|
radFcdT1A OBJECT IDENTIFIER ::= { radSysWan 36 }
|
|
radFcdE1A OBJECT IDENTIFIER ::= { radSysWan 37 }
|
|
radFcdW OBJECT IDENTIFIER ::= { radSysWan 38 }
|
|
radFcdSTM OBJECT IDENTIFIER ::= { radSysWan 39 }
|
|
|
|
radHtuE1Sa OBJECT IDENTIFIER ::= { radSysWan 40 }
|
|
radHtuE1 OBJECT IDENTIFIER ::= { radSysWan 41 } --card
|
|
radHtu2Sa OBJECT IDENTIFIER ::= { radSysWan 42 }
|
|
radHtu2 OBJECT IDENTIFIER ::= { radSysWan 43 } --card
|
|
radAsmi450R768Sa OBJECT IDENTIFIER ::= { radSysWan 44 }
|
|
radAsmi450R768 OBJECT IDENTIFIER ::= { radSysWan 45 } --card
|
|
radAsmi450R1152Sa OBJECT IDENTIFIER ::= { radSysWan 46 }
|
|
radAsmi450R1152 OBJECT IDENTIFIER ::= { radSysWan 47 } --card
|
|
|
|
radLrs12F OBJECT IDENTIFIER ::= { radSysWan 48 }
|
|
radLrs12B OBJECT IDENTIFIER ::= { radSysWan 49 }
|
|
radLrs52 OBJECT IDENTIFIER ::= { radSysWan 50 }
|
|
|
|
radHcdE1Sa OBJECT IDENTIFIER ::= { radSysWan 51 }
|
|
radHcdE1 OBJECT IDENTIFIER ::= { radSysWan 52 } --card
|
|
radHtuT1Sa OBJECT IDENTIFIER ::= { radSysWan 53 }
|
|
radHtuT1 OBJECT IDENTIFIER ::= { radSysWan 54 } --card
|
|
|
|
radOptimux4E1 OBJECT IDENTIFIER ::= { radSysWan 55 }
|
|
radOptimux4T1 OBJECT IDENTIFIER ::= { radSysWan 56 }
|
|
radOptimuxXLE1 OBJECT IDENTIFIER ::= { radSysWan 57 }
|
|
radOptimuxXLT1 OBJECT IDENTIFIER ::= { radSysWan 58 }
|
|
radOptimuxXL16E1 OBJECT IDENTIFIER ::= { radSysWan 59 }
|
|
|
|
radImx64 OBJECT IDENTIFIER ::= { radSysWan 60 }
|
|
radImx6L OBJECT IDENTIFIER ::= { radSysWan 61 }
|
|
radImx2 OBJECT IDENTIFIER ::= { radSysWan 62 }
|
|
radImx4T1 OBJECT IDENTIFIER ::= { radSysWan 63 }
|
|
radImx4E1 OBJECT IDENTIFIER ::= { radSysWan 64 }
|
|
radImx2T1E1 OBJECT IDENTIFIER ::= { radSysWan 65 }
|
|
radImxi4 OBJECT IDENTIFIER ::= { radSysWan 66 }
|
|
|
|
radOptimux155 OBJECT IDENTIFIER ::= { radSysWan 67 } --SA
|
|
radOptimux4T1L OBJECT IDENTIFIER ::= { radSysWan 68 } --SA Low Cost
|
|
radOptimux4E1L OBJECT IDENTIFIER ::= { radSysWan 69 } --SA Low Cost
|
|
radHtuE1SaV2 OBJECT IDENTIFIER ::= { radSysWan 70 }
|
|
radHtuE1V2 OBJECT IDENTIFIER ::= { radSysWan 71 } --card
|
|
radFomiE3 OBJECT IDENTIFIER ::= { radSysWan 72 } --card
|
|
radFomiT3 OBJECT IDENTIFIER ::= { radSysWan 73 } --card
|
|
radOpt4E1C OBJECT IDENTIFIER ::= { radSysWan 74 } --card
|
|
radOpt4T1C OBJECT IDENTIFIER ::= { radSysWan 75 } --card
|
|
radPrbiE3 OBJECT IDENTIFIER ::= { radSysWan 76 } --SA
|
|
radPrbiT3 OBJECT IDENTIFIER ::= { radSysWan 77 } --SA
|
|
radHcd4Sa OBJECT IDENTIFIER ::= { radSysWan 78 } --SA
|
|
radOptimuxT3 OBJECT IDENTIFIER ::= { radSysWan 79 } --SA
|
|
|
|
radFRmon OBJECT IDENTIFIER ::= { radSysWan 80 }
|
|
radIpMux4 OBJECT IDENTIFIER ::= { radSysWan 81 }
|
|
radIpMux1 OBJECT IDENTIFIER ::= { radSysWan 82 }
|
|
radIpMux16 OBJECT IDENTIFIER ::= { radSysWan 83 }
|
|
radIpMux1E OBJECT IDENTIFIER ::= { radSysWan 84 }
|
|
radVmux2100 OBJECT IDENTIFIER ::= { radSysWan 85 }
|
|
radMP104 OBJECT IDENTIFIER ::= { radSysWan 86 }
|
|
radMP204 OBJECT IDENTIFIER ::= { radSysWan 87 }
|
|
radVmux110 OBJECT IDENTIFIER ::= { radSysWan 88 }
|
|
-- reserved for radVmux105 OBJECT IDENTIFIER ::= { radSysWan 89 }
|
|
|
|
radFcd155 OBJECT IDENTIFIER ::= { radSysWan 90 } --SA
|
|
radIpMux8 OBJECT IDENTIFIER ::= { radSysWan 91 }
|
|
radOptimux155DS3 OBJECT IDENTIFIER ::= { radSysWan 92 } --SA
|
|
radOptimuxT3L OBJECT IDENTIFIER ::= { radSysWan 93 } --SA Low Cost
|
|
-- reserved for radIpMux1000 OBJECT IDENTIFIER ::= { radSysWan 94 }
|
|
radOp16E1L OBJECT IDENTIFIER ::= { radSysWan 95 } --19 inch box
|
|
radOp16E1LS OBJECT IDENTIFIER ::= { radSysWan 96 } --half 19 inch box (single)
|
|
radPRBm20 OBJECT IDENTIFIER ::= { radSysWan 97 } -- half 19 inch box
|
|
radPRBm22 OBJECT IDENTIFIER ::= { radSysWan 98 } -- 19 inch box
|
|
-- reserved for radAsmi52Sa OBJECT IDENTIFIER ::= { radSysWan 99 }
|
|
|
|
radOpXLE1 OBJECT IDENTIFIER ::= { radSysWan 100 } -- New-Look
|
|
radOpXLT1 OBJECT IDENTIFIER ::= { radSysWan 101 } -- New-Look
|
|
radOpXL16E1 OBJECT IDENTIFIER ::= { radSysWan 102 } -- New-Look
|
|
|
|
|
|
radSysBRG OBJECT IDENTIFIER ::= { systems 4 } -- RAD Bridges products
|
|
|
|
radTRE1 OBJECT IDENTIFIER ::= { radSysBRG 1 } -- RAD Bridges products
|
|
|
|
radTRE1D OBJECT IDENTIFIER ::= { radSysBRG 2 } -- RAD Bridges products
|
|
|
|
radTRE8 OBJECT IDENTIFIER ::= { radSysBRG 3 } -- RAD Bridges products
|
|
|
|
radTRE8D OBJECT IDENTIFIER ::= { radSysBRG 4 } -- RAD Bridges products
|
|
|
|
radMBE1 OBJECT IDENTIFIER ::= { radSysBRG 5 } -- RAD Bridges products
|
|
|
|
radMBE1D OBJECT IDENTIFIER ::= { radSysBRG 6 } -- RAD Bridges products
|
|
|
|
radMBE8 OBJECT IDENTIFIER ::= { radSysBRG 7 } -- RAD Bridges products
|
|
|
|
radMBE8D OBJECT IDENTIFIER ::= { radSysBRG 8 } -- RAD Bridges products
|
|
|
|
radMLBT OBJECT IDENTIFIER ::= { radSysBRG 9 } -- RAD Bridges products
|
|
|
|
radFEB4DAS OBJECT IDENTIFIER ::= { radSysBRG 10 } -- RAD Bridges products
|
|
|
|
radTrimBrg10 OBJECT IDENTIFIER ::= { radSysBRG 11 } -- RAD Bridges products
|
|
|
|
radTrimBrg16 OBJECT IDENTIFIER ::= { radSysBRG 12 } -- RAD Bridges products
|
|
|
|
radRRTRE8 OBJECT IDENTIFIER ::= { radSysBRG 13 } -- RAD Bridges products
|
|
|
|
radRRTRE8D OBJECT IDENTIFIER ::= { radSysBRG 14 } -- RAD Bridges products
|
|
|
|
radRRMLBT OBJECT IDENTIFIER ::= { radSysBRG 15 } -- RAD Bridges products
|
|
|
|
radRRMLBTF OBJECT IDENTIFIER ::= { radSysBRG 16 } -- RAD Bridges products
|
|
|
|
radRRTRE1D OBJECT IDENTIFIER ::= { radSysBRG 17 } -- RAD Bridges products
|
|
|
|
radTRERAS OBJECT IDENTIFIER ::= { radSysBRG 18 } -- RAD Bridges products
|
|
|
|
radTRERASa OBJECT IDENTIFIER ::= { radSysBRG 19 } -- RAD Bridges products
|
|
|
|
radMBERAS OBJECT IDENTIFIER ::= { radSysBRG 20 } -- RAD Bridges products
|
|
|
|
radMBERASa OBJECT IDENTIFIER ::= { radSysBRG 21 } -- RAD Bridges products
|
|
|
|
radFEB4FDX OBJECT IDENTIFIER ::= { radSysBRG 22 } -- RAD Bridges products
|
|
|
|
radFEB4SAS OBJECT IDENTIFIER ::= { radSysBRG 23 } -- RAD Bridges products
|
|
|
|
radRRFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 24 } -- RAD Bridges products
|
|
|
|
radRRFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 25 } -- RAD Bridges products
|
|
|
|
radFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 26 } -- RAD Bridges products
|
|
|
|
radFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 27 } -- RAD Bridges products
|
|
|
|
radFastWay100 OBJECT IDENTIFIER ::= { radSysBRG 28 } -- RAD Bridges products
|
|
|
|
radSysCnvrtr OBJECT IDENTIFIER ::= { systems 5 } -- RAD Converters products
|
|
|
|
radSTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 1 } -- RAD Converters products
|
|
|
|
radSTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 3 } -- RAD Converters products
|
|
|
|
radSTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 4 } -- RAD Converters products
|
|
|
|
radSTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 6 } -- RAD Converters products
|
|
|
|
radFTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 10 } -- RAD Converters products
|
|
|
|
radFTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 12 } -- RAD Converters products
|
|
|
|
radFTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 13 } -- RAD Converters products
|
|
|
|
radFTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 15 } -- RAD Converters products
|
|
|
|
radSEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 20 } -- RAD Converters products
|
|
|
|
radSEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 22 } -- RAD Converters products
|
|
|
|
radSEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 23 } -- RAD Converters products
|
|
|
|
radSEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 25 } -- RAD Converters products
|
|
|
|
radFEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 30 } -- RAD Converters products
|
|
|
|
radFEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 32 } -- RAD Converters products
|
|
|
|
radFEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 33 } -- RAD Converters products
|
|
|
|
radFEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 35 } -- RAD Converters products
|
|
|
|
radRIC155 OBJECT IDENTIFIER ::= { radSysCnvrtr 36 } -- RAD Converters products
|
|
|
|
|
|
radSysStkHub OBJECT IDENTIFIER ::= { systems 7 } -- RAD Stackable products
|
|
|
|
radRBHE OBJECT IDENTIFIER ::= { radSysStkHub 1 } -- RAD Stackable products
|
|
|
|
radRBHT OBJECT IDENTIFIER ::= { radSysStkHub 2 } -- RAD Stackable products
|
|
|
|
radRBHEEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for RAD Stackable products."
|
|
::= { radRBHE 0 }
|
|
|
|
radRBHTEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for RAD Stackable products."
|
|
::= { radRBHT 0 }
|
|
|
|
radETS4fddiDAS OBJECT IDENTIFIER ::= { radSysStkHub 3 } -- RAD Stackable products
|
|
|
|
radETS4fddiSAS OBJECT IDENTIFIER ::= { radSysStkHub 4 } -- RAD Stackable products
|
|
|
|
radSAHEMX OBJECT IDENTIFIER ::= { radSysStkHub 5 } -- RAD Stackable products
|
|
|
|
radSAHTM OBJECT IDENTIFIER ::= { radSysStkHub 6 } -- RAD Stackable products
|
|
|
|
radETS4 OBJECT IDENTIFIER ::= { radSysStkHub 7 } -- RAD Stackable products
|
|
|
|
radSAHEMU OBJECT IDENTIFIER ::= { radSysStkHub 8 } -- RAD Stackable products
|
|
|
|
|
|
unknown OBJECT IDENTIFIER ::= { radSysStkHub 9 } -- RAD Stackable products
|
|
|
|
radSAH16Eint OBJECT IDENTIFIER ::= { radSysStkHub 10 } -- RAD Stackable products
|
|
|
|
radSAH16Tint OBJECT IDENTIFIER ::= { radSysStkHub 11 } -- RAD Stackable products
|
|
|
|
radSAH16Eext OBJECT IDENTIFIER ::= { radSysStkHub 12 } -- RAD Stackable products
|
|
|
|
radSAH16Text OBJECT IDENTIFIER ::= { radSysStkHub 13 } -- RAD Stackable products
|
|
|
|
|
|
|
|
radSysPS OBJECT IDENTIFIER ::= { systems 8 } -- RAD Packet Switch (PS) products
|
|
|
|
radSysPSEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for RAD Packet Switch (PS) products."
|
|
::= { radSysPS 0 }
|
|
|
|
radSPS2 OBJECT IDENTIFIER ::= { radSysPS 1 } -- RAD Packet Switch (PS) products
|
|
|
|
radSPS3 OBJECT IDENTIFIER ::= { radSysPS 2 } -- RAD Packet Switch (PS) products
|
|
|
|
radSPS6 OBJECT IDENTIFIER ::= { radSysPS 3 } -- RAD Packet Switch (PS) products
|
|
|
|
radSPS9 OBJECT IDENTIFIER ::= { radSysPS 4 } -- RAD Packet Switch (PS) products
|
|
|
|
radSPS12 OBJECT IDENTIFIER ::= { radSysPS 5 } -- RAD Packet Switch (PS) products
|
|
|
|
radAPD2 OBJECT IDENTIFIER ::= { radSysPS 6 } -- RAD Packet Switch (PS) products
|
|
|
|
radAPD8 OBJECT IDENTIFIER ::= { radSysPS 7 } -- RAD Packet Switch (PS) products
|
|
|
|
radAPS8 OBJECT IDENTIFIER ::= { radSysPS 8 } -- RAD Packet Switch (PS) products
|
|
|
|
radAPS16 OBJECT IDENTIFIER ::= { radSysPS 9 } -- RAD Packet Switch (PS) products
|
|
|
|
radAPS24 OBJECT IDENTIFIER ::= { radSysPS 10 } -- RAD Packet Switch (PS) products
|
|
|
|
radSPS3S OBJECT IDENTIFIER ::= { radSysPS 11} -- RAD Packet Switch (PS) products
|
|
|
|
radFPS8 OBJECT IDENTIFIER ::= { radSysPS 12} -- RAD Packet Switch (PS) products
|
|
|
|
radFPS12 OBJECT IDENTIFIER ::= { radSysPS 13} -- RAD Packet Switch (PS) products
|
|
|
|
radSPS3ScSL OBJECT IDENTIFIER ::= { radSysPS 14} -- RAD Packet Switch (PS) products
|
|
|
|
radSPS3Sc2S OBJECT IDENTIFIER ::= { radSysPS 15} -- RAD Packet Switch (PS) products
|
|
|
|
radFPS8c OBJECT IDENTIFIER ::= { radSysPS 16} -- RAD Packet Switch (PS) products
|
|
|
|
radFPS4 OBJECT IDENTIFIER ::= { radSysPS 17} -- RAD Packet Switch (PS) products
|
|
|
|
|
|
|
|
radSysEth OBJECT IDENTIFIER ::= { systems 9 } -- RAD Ethernet products
|
|
|
|
radEP8T OBJECT IDENTIFIER ::= {radSysEth 1} -- RAD Ethernet products
|
|
|
|
radEP4TAUI OBJECT IDENTIFIER ::= {radSysEth 2} -- RAD Ethernet products
|
|
|
|
radEP4T2FL OBJECT IDENTIFIER ::= {radSysEth 3} -- RAD Ethernet products
|
|
|
|
radEP4TFL OBJECT IDENTIFIER ::= {radSysEth 4} -- RAD Ethernet products
|
|
|
|
radEP4FL OBJECT IDENTIFIER ::= {radSysEth 5} -- RAD Ethernet products
|
|
|
|
|
|
radEPR8T OBJECT IDENTIFIER ::= {radSysEth 7} -- RAD Ethernet products
|
|
|
|
radEPR4TAUI OBJECT IDENTIFIER ::= {radSysEth 8} -- RAD Ethernet products
|
|
|
|
radEPR4T2FL OBJECT IDENTIFIER ::= {radSysEth 9} -- RAD Ethernet products
|
|
|
|
radEPR4TFL OBJECT IDENTIFIER ::= {radSysEth 10} -- RAD Ethernet products
|
|
|
|
radEPR4FL OBJECT IDENTIFIER ::= {radSysEth 11} -- RAD Ethernet products
|
|
|
|
|
|
|
|
radSysRtr OBJECT IDENTIFIER ::= { systems 11 } -- RAD Router products
|
|
|
|
radSysRtrEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for RAD Router products."
|
|
::= { radSysRtr 0 }
|
|
|
|
radRTED OBJECT IDENTIFIER ::= {radSysRtr 1} -- RAD Router products
|
|
|
|
radRTEM OBJECT IDENTIFIER ::= {radSysRtr 2} -- RAD Router products
|
|
|
|
radRTEC OBJECT IDENTIFIER ::= {radSysRtr 3} -- RAD Router products
|
|
|
|
radWebRanger OBJECT IDENTIFIER ::= {radSysRtr 4} -- RAD Router products
|
|
|
|
radTinyRouter OBJECT IDENTIFIER ::= {radSysRtr 5} -- RAD Router products
|
|
|
|
radLA240 OBJECT IDENTIFIER ::= {radSysRtr 6} -- RAD Router products
|
|
|
|
radSuperLan OBJECT IDENTIFIER ::= {radSysRtr 7} -- RAD Router products (LA-240)
|
|
|
|
radLA240I OBJECT IDENTIFIER ::= {radSysRtr 8} -- RAD Router products
|
|
|
|
radFcdIsdn OBJECT IDENTIFIER ::= {radSysRtr 9} -- RAD Router products
|
|
|
|
radEFcdIp OBJECT IDENTIFIER ::= {radSysRtr 10} -- RAD Router products (FCD-IP/D)
|
|
|
|
radFcdIpD OBJECT IDENTIFIER ::= {radSysRtr 11} -- RAD Router products
|
|
|
|
radFcdIpM OBJECT IDENTIFIER ::= {radSysRtr 12} -- RAD Router products (LA-240)
|
|
|
|
|
|
radSysAtm OBJECT IDENTIFIER ::= { systems 12 } -- RAD ATM products
|
|
|
|
radSysAtmEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for RAD ATM products."
|
|
::= { radSysAtm 0 }
|
|
|
|
radStarSwitch OBJECT IDENTIFIER ::= {radSysAtm 1} --RAD StartSwitch products
|
|
|
|
radStarSwitchATM25 OBJECT IDENTIFIER ::= {radStarSwitch 1} --RAD StartSwitch products
|
|
radStarSwitchATM25L OBJECT IDENTIFIER ::= {radStarSwitch 2} --RAD StartSwitch products
|
|
radStarSwitchATM155 OBJECT IDENTIFIER ::= {radStarSwitch 3} --RAD StartSwitch products
|
|
|
|
|
|
radAtmCsuDsu OBJECT IDENTIFIER ::= {radSysAtm 2} --RAD CSU/DSU products
|
|
|
|
radAmcdE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 1} -- RAD CSU/DSU products
|
|
radAmcdT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 2} -- RAD CSU/DSU products
|
|
radAce20E OBJECT IDENTIFIER ::= {radAtmCsuDsu 3} -- RAD CSU/DSU products
|
|
radAce20T OBJECT IDENTIFIER ::= {radAtmCsuDsu 4} -- RAD CSU/DSU products
|
|
|
|
radAce2005 OBJECT IDENTIFIER ::= { radAtmCsuDsu 5} -- RAD ACE2005
|
|
radAce2002 OBJECT IDENTIFIER ::= { radAtmCsuDsu 6} -- RAD ACE2002
|
|
radAce2002E OBJECT IDENTIFIER ::= { radAtmCsuDsu 7} -- RAD ACE2002E
|
|
|
|
radAce2E OBJECT IDENTIFIER ::= {radAtmCsuDsu 8} -- RAD CSU/DSU products
|
|
radAce2T OBJECT IDENTIFIER ::= {radAtmCsuDsu 9} -- RAD CSU/DSU products
|
|
|
|
radMlAtmE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 10} -- RAD ATM Piggy
|
|
radMlAtmT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 11} -- RAD ATM Piggy
|
|
|
|
radAmc102 OBJECT IDENTIFIER ::= {radAtmCsuDsu 12} -- RAD AMC102
|
|
radAmc102c OBJECT IDENTIFIER ::= {radAtmCsuDsu 13} -- RAD AMC102 CARD
|
|
|
|
radAce202 OBJECT IDENTIFIER ::= { radAtmCsuDsu 14} -- RAD ACE202
|
|
|
|
radAce OBJECT IDENTIFIER ::= {radSysAtm 3} --RAD ACE products
|
|
radAce101 OBJECT IDENTIFIER ::= {radAce 1} -- RAD ACE101
|
|
radAce102 OBJECT IDENTIFIER ::= {radAce 2} -- RAD ACE102
|
|
radAce50 OBJECT IDENTIFIER ::= {radAce 3} -- RAD ACE50
|
|
radAce52 OBJECT IDENTIFIER ::= {radAce 4} -- RAD ACE52
|
|
|
|
radSysLA OBJECT IDENTIFIER ::= {systems 13} --RAD IAD (Integrated Access Device) products
|
|
radLA140 OBJECT IDENTIFIER ::= {radSysLA 1} -- RAD LA-140
|
|
radLA110 OBJECT IDENTIFIER ::= {radSysLA 2} -- RAD LA-110
|
|
radLA104 OBJECT IDENTIFIER ::= {radSysLA 3} -- RAD LA-104 (LA-110 with IMA)
|
|
|
|
radSysTerminal OBJECT IDENTIFIER ::= {systems 100} --RAD Terminal Meta-MIB;
|
|
-- no objects should be added to this branch in RAD MIB.
|
|
|
|
|
|
agnt OBJECT IDENTIFIER ::= { radGen 2}
|
|
-- agent general tree
|
|
-- Agent General
|
|
agnHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ASCII string for description and display of the agent hardware version,
|
|
as it is known by the agent software.The user can update the version
|
|
upon request when he changes components in the agent's module "
|
|
::= { agnt 1 }
|
|
|
|
agnTrapMask OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this attribute determines the type of traps the
|
|
agent should mask and not send to the management console. The
|
|
value is differently determined for different products. There are
|
|
mainly two methods:
|
|
- an integer number, specifying the traps' severity.
|
|
- a sum of 2**n, where n is a bit assigned to a certain
|
|
masked trap group.
|
|
User should consult the product specification, to find out
|
|
the method employed."
|
|
::= { agnt 2 }
|
|
|
|
agnTrapValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The value of the trap decoded in internal RAD format. Full description is given
|
|
in the Trap definition file"
|
|
::= {agnt 3}
|
|
|
|
agnChangeCnt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of changes in system configuration that were reported to the
|
|
manager since last cold start"
|
|
::= {agnt 4 }
|
|
|
|
agnSpecific OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Object identifier of entity containing additional information
|
|
regarding this instance."
|
|
::= { agnt 5}
|
|
|
|
agnConfigMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Full configuration message coded in internal RAD application format.
|
|
This entry describes agent's configuration.
|
|
|
|
For MP-2200 R3, this object describes agent's support of the V5.1
|
|
feature: 1 octet ; bit 0 (LSB).
|
|
'1' - V5.1 feature is supported
|
|
'0' - V5.1 feature is not supported."
|
|
::= { agnt 6 }
|
|
|
|
-- Manager table to record all IP addresses
|
|
|
|
mngTrapIpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MngEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table indicates the destination address of the traps.
|
|
Internally it will be limited to ten addresses. "
|
|
::= { agnt 7 }
|
|
|
|
mngEntry OBJECT-TYPE
|
|
SYNTAX MngEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mngID }
|
|
::= { mngTrapIpTable 1 }
|
|
|
|
|
|
MngEntry ::=
|
|
SEQUENCE {
|
|
mngID
|
|
Integer32,
|
|
mngIP
|
|
IpAddress,
|
|
mngIPMask
|
|
IpAddress,
|
|
mngTrapMask
|
|
Integer32
|
|
}
|
|
|
|
mngID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This value indicates an index of a specific IP address"
|
|
::= { mngEntry 1 }
|
|
|
|
mngIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry. "
|
|
::= { mngEntry 2 }
|
|
|
|
mngIPMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This value indicates the mask of the destination addresses of the traps. "
|
|
::= { mngEntry 3 }
|
|
|
|
mngTrapMask OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this attribute determines the type of traps the
|
|
agent should mask and not send to this NMS. The
|
|
value is differently determined for different products. There are
|
|
mainly two methods:
|
|
- an integer number, specifying the traps' severity.
|
|
- a sum of 2**n, where n is a bit assigned to a certain
|
|
masked trap group.
|
|
User should consult the product specification, to find out
|
|
the method employed."
|
|
::= { mngEntry 4 }
|
|
|
|
agnIndication OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
faulty (1), -- =major
|
|
warning (2),
|
|
normal (3), -- off
|
|
minor (4),
|
|
major (5),
|
|
event (6),
|
|
critical(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Attribute describing the state of the entity the agent is responsible for.
|
|
In case of a modular entity, the value of this attribute will be according
|
|
to the component which is in the worst state.
|
|
The order of severity (from top to bottom) is:
|
|
critical-> major (or faulty)-> minor-> event-> warning-> normal (off)."
|
|
::= { agnt 8 }
|
|
|
|
|
|
agnMonitorModeCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
off(2),
|
|
on(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce the agent to change its mode of operation to
|
|
Monitor Mode"
|
|
::= {agnt 9}
|
|
|
|
agnLed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry specifies the LEDs status of the agent module . Each led will be represented by 4
|
|
bits where the first 2 bits (left) will specify the status :
|
|
(00=NA, 01=OFF, 10=ON, 11=BLINK),
|
|
and the next two bits (right) will specify the color :
|
|
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)"
|
|
::= {agnt 10}
|
|
|
|
trapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes the last few traps generated by the agent, for future retrieval. The table
|
|
has a limited capacity. If traps are not retrieved in proper time, they will be
|
|
over-written by new traps "
|
|
::= {agnt 11}
|
|
|
|
trapEntry OBJECT-TYPE
|
|
SYNTAX TrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { trapID }
|
|
::= { trapTable 1 }
|
|
|
|
TrapEntry ::=
|
|
SEQUENCE {
|
|
trapID
|
|
Integer32,
|
|
trapVal
|
|
DisplayString,
|
|
trapTimeSinceOccurrence
|
|
TimeTicks
|
|
}
|
|
|
|
trapID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This value indicates an index of a specific trap "
|
|
::= { trapEntry 1 }
|
|
|
|
trapVal OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is the actual ASCII description of the trap. "
|
|
::= { trapEntry 2 }
|
|
|
|
trapTimeSinceOccurrence OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value indicates the amount of time passed since the occurrence of the event that
|
|
trigger this trap. "
|
|
::= { trapEntry 3 }
|
|
|
|
fileTransfer OBJECT IDENTIFIER ::= { agnt 12 }
|
|
|
|
fileServerIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of the server from which the file is loaded "
|
|
::= { fileTransfer 1 }
|
|
|
|
fileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the file to be loaded. For protection, read returns
|
|
NULL. "
|
|
::= { fileTransfer 2 }
|
|
|
|
fileTransCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
swDwnLoad (1),
|
|
configDwnLoad (2),
|
|
configUpLoad (3),
|
|
coProcDwnLoad (4),
|
|
stateUpLoad (5),
|
|
dwnLoadUserFile (6),
|
|
upLoadUserFile (7),
|
|
swDwnLoadAndReset (8),
|
|
swUpLoad (9),
|
|
noOp (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The command to be executed on fileName at fileServerIP."
|
|
::= { fileTransfer 3 }
|
|
|
|
-- tftp group
|
|
|
|
tftpRetryTimeOut OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" General Retransmission time-out value (seconds) "
|
|
-- DEFVAL { 15 }
|
|
::= { fileTransfer 4 }
|
|
|
|
tftpTotalTimeOut OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Total Retransmission time-out value (seconds) "
|
|
-- DEFVAL { 60 }
|
|
::= { fileTransfer 5 }
|
|
|
|
tftpStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOp(2),
|
|
connecting(3),
|
|
transferringData(4),
|
|
endedTimeOut(5),
|
|
endedOk(6),
|
|
error(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of tftp session. When a session ended with success,
|
|
the tftpStatus should be endedOk(6). Before restarting a
|
|
tftp session, the NMS should set the tftpStatus to noOp(2).
|
|
That's the reason of MAX-ACCESS read-write to this field."
|
|
DEFVAL { noOp}
|
|
::= { fileTransfer 6 }
|
|
|
|
tftpError OBJECT-TYPE
|
|
SYNTAX OCTET STRING ( SIZE(2) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The MSB represents the standard error code.
|
|
The LSB represents the private error code.
|
|
0x0000 is No Error
|
|
0x0100 is File Not Found
|
|
0x0400 is Illegal TFTP operation
|
|
0x0500 is Unknown transfer ID
|
|
0x0001 is Server Overflow
|
|
0x0002 is No empty UDP port
|
|
0x0003 is No empty connection
|
|
0x0004 is Illegal File Mode
|
|
0x0007 is Illegal PDU size "
|
|
DEFVAL { '0000'h }
|
|
::= { fileTransfer 7 }
|
|
|
|
fileTransferToSubSystems OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object represents the sub-systems the fileTransCmd
|
|
refers to. It should be used when a system is divided
|
|
to sub-systems and each sub-system (or part of them) can
|
|
have a different SW/Configuration.
|
|
|
|
Each bit of this object will represent one of the sub-systems.
|
|
Bit='1' - APPLY to respective sub-system
|
|
Bit='0' - DO NOT APPLY to respective sub-system
|
|
|
|
For the meaning of each bit, see product's specification.
|
|
User will select the sub-systems envolved by filling-in the bits
|
|
that represent these sub-systems.
|
|
In this case, the file represented by 'fileName' will
|
|
include several parts, each representing one of the sub-systems.
|
|
The agent will refer only to the part/s indicated by this object.
|
|
|
|
0 Octet Strings = not applicable
|
|
DEFVAL = 0h for the products that support this object."
|
|
::= { fileTransfer 8 }
|
|
|
|
|
|
fileNameWithinProduct OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The file name used by the product within the product file system."
|
|
::= { fileTransfer 9 }
|
|
|
|
--Internal SW Download table
|
|
|
|
intSwdlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IntSwdlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameters table is for
|
|
internal Software down load. It also includes data
|
|
about all files contained in the Object from which
|
|
down-load is performed."
|
|
::= { fileTransfer 10 }
|
|
|
|
intSwdlEntry OBJECT-TYPE
|
|
SYNTAX IntSwdlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {intSwdlObjIdx, intSwdlFileIdx }
|
|
::= { intSwdlTable 1}
|
|
|
|
IntSwdlEntry ::=
|
|
SEQUENCE {
|
|
intSwdlObjIdx Integer32,
|
|
intSwdlFileIdx Integer32,
|
|
intSwdlFileName DisplayString,
|
|
intSwdlFileSwVer DisplayString,
|
|
intSwdlSwDate DisplayString,
|
|
intSwdlSize DisplayString,
|
|
intSwdlCmd INTEGER,
|
|
intSwdlToSubSystem OCTET STRING
|
|
}
|
|
|
|
intSwdlObjIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the object from which down-load is performed."
|
|
::= {intSwdlEntry 1}
|
|
|
|
intSwdlFileIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the files included in intSwdlObjIdx.
|
|
One of these files can be selected to be internally
|
|
downloaded."
|
|
::= {intSwdlEntry 2}
|
|
|
|
intSwdlFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the file."
|
|
::= {intSwdlEntry 3}
|
|
|
|
intSwdlFileSwVer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The software version of the file."
|
|
::= {intSwdlEntry 4}
|
|
|
|
intSwdlSwDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The software version date of the file."
|
|
::= {intSwdlEntry 5}
|
|
|
|
intSwdlSize OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of the file."
|
|
::= {intSwdlEntry 6}
|
|
|
|
intSwdlCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The command to down-load a SW file to an object.
|
|
The Agent will change the value of this MIB object to off(2)
|
|
automatically, after accepting the command."
|
|
::= {intSwdlEntry 7}
|
|
|
|
intSwdlToSubSystem OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object defines the subsystem for download.
|
|
Bit='1'- APPLY to respective sub system.
|
|
Bit='0'- DO NOT APPLY to respective sub system.
|
|
For more details see product specification.
|
|
For every octet bit0=LSB, bit7=MSB"
|
|
::= { intSwdlEntry 8 }
|
|
|
|
--SW Download Status table
|
|
|
|
swdlStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwdlStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameters table is for software download status.
|
|
It also includes data about the files down-loaded or
|
|
attempted to be down-loaded."
|
|
::= { fileTransfer 11 }
|
|
|
|
swdlStatusEntry OBJECT-TYPE
|
|
SYNTAX SwdlStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {swdlStatusTypeIdx, swdlStatusIdx }
|
|
::= { swdlStatusTable 1}
|
|
|
|
SwdlStatusEntry ::=
|
|
SEQUENCE {
|
|
swdlStatusTypeIdx Integer32,
|
|
swdlStatusIdx Integer32,
|
|
swdlStatusFileName DisplayString,
|
|
swdlStatusSlot DisplayString,
|
|
swdlStatusSubSystem DisplayString,
|
|
swdlStatusStatus Integer32,
|
|
swdlStatusTime DisplayString
|
|
}
|
|
|
|
swdlStatusTypeIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the down-load type (e.g. external (1) or internal (2))."
|
|
::= {swdlStatusEntry 1}
|
|
|
|
swdlStatusIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the status rows."
|
|
::= {swdlStatusEntry 2}
|
|
|
|
swdlStatusFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the file."
|
|
::= {swdlStatusEntry 3}
|
|
|
|
swdlStatusSlot OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot of the updated (or attempted to be updated) object."
|
|
::= {swdlStatusEntry 4}
|
|
|
|
swdlStatusSubSystem OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The subsystem that updated (or attempted to be updated)."
|
|
::= {swdlStatusEntry 5}
|
|
|
|
swdlStatusStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the down load process.
|
|
Value: Fail (2), OK (3), InProcess (4)."
|
|
::= {swdlStatusEntry 6}
|
|
|
|
swdlStatusTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB parameter indicates the time SW download was finished.
|
|
The format shuld be YYYY-MM-DD, hh:mm:ss"
|
|
|
|
::= {swdlStatusEntry 7}
|
|
|
|
clearDwldStatusLog OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object clears the status log.
|
|
Value: off(2), external(3), internal(4)
|
|
The Agent will change the value of this MIB object to off(2)
|
|
automatically, after accepting the command ."
|
|
::= { fileTransfer 12 }
|
|
|
|
|
|
systemReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
on (3), --HW
|
|
resetConfig (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset action to be performed on the system."
|
|
::= { agnt 13 }
|
|
|
|
systemTiming OBJECT IDENTIFIER ::= { agnt 14 }
|
|
|
|
systemDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System date."
|
|
::= { systemTiming 1 }
|
|
|
|
systemTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System time."
|
|
::= { systemTiming 2 }
|
|
|
|
|
|
systemPort OBJECT IDENTIFIER ::= { agnt 15 }
|
|
|
|
physicalConnectorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PhysicalConnectorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes the connector type of ports or interfaces."
|
|
::= {systemPort 1}
|
|
|
|
physicalConnectorEntry OBJECT-TYPE
|
|
SYNTAX PhysicalConnectorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {portIdx}
|
|
::= { physicalConnectorTable 1 }
|
|
|
|
PhysicalConnectorEntry ::=
|
|
SEQUENCE {
|
|
portIdx
|
|
Integer32,
|
|
physicalConnector
|
|
INTEGER,
|
|
portOptWaveLength
|
|
INTEGER,
|
|
portOptMode
|
|
INTEGER,
|
|
portBalance
|
|
INTEGER
|
|
}
|
|
|
|
portIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index of the specific port or interface.
|
|
For a port, the index will be as agreed between agent and
|
|
application.
|
|
For an interface, ifIndex may be used."
|
|
::= { physicalConnectorEntry 1 }
|
|
|
|
physicalConnector OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other (1),
|
|
v35 (2), --34 pin female
|
|
rs530 (3), --DB25
|
|
x21 (4), --DB15
|
|
bnc (5),
|
|
utp (6), --RJ45
|
|
aui (7),
|
|
rs422 (8), --DB25
|
|
crossUtp (9), --RJ45
|
|
rj45 (10),
|
|
v24 (11), --DB25
|
|
g703 (12), --TB5
|
|
termBlock3AndRj45 (13),
|
|
terminalBlock3 (14),
|
|
terminalBlock5 (15),
|
|
terminalBlock7 (16),
|
|
db25 (17),
|
|
db15 (18),
|
|
rj45ethernet (19),
|
|
termBlock5AndRj45 (20),
|
|
db9 (21),
|
|
g703E1 (22), --BNC-RJ45-BNC
|
|
g703E1-LTU (23), --BNC-RJ45-BNC
|
|
sc (24), --sc optical
|
|
st (25), --st optical
|
|
stl (26),
|
|
fc (27), --fc optical
|
|
tb5w (28), --Term-Block-5-Wire (for HCD)
|
|
termBlock6AndRj45 (29),
|
|
ethBnc (30),
|
|
scsi26 (31), --SCSI with 26 pins
|
|
eth4381 (32), --RJ45 with two embeded LEDs
|
|
twoBnc (33), --Two BNC
|
|
scsi50 (34), --SCSI with 50 pins
|
|
twoMiniBnc (35), --Two mini BNC
|
|
sf1 (36), --sf1=single fiber optical
|
|
terminalBlock4 (37),
|
|
sf2 (38), --sf2=single fiber optical
|
|
db25Balanced (39), --DB25 Balanced
|
|
v36 (40),
|
|
block4W (41), --like in WR connector for Modems
|
|
iripRj45 (42),
|
|
irEthQRj45 (43),
|
|
iripBnc (44),
|
|
rs530WA (45), --rs530/IR that solves a wander problem for SDH network
|
|
v35WA (46), --v35/IR that solves a wander problem for SDH network
|
|
irEthQBnc (47),
|
|
v35Db25 (48), --V.35 with connector DB25
|
|
rj11 (49), --Used for FXS & FXO
|
|
mtrj (50), --optical
|
|
lc (51), --optical
|
|
terminalBlock2 (52),
|
|
irEth10s100 (53), --IR-ETH 10/100
|
|
scsi68 (54), -- SCSI 68 pins
|
|
sf3 (55), -- sf3=single fiber of sc optical
|
|
fcLH (56), -- fc Long Haul
|
|
telco50 (57), -- TELCO 50
|
|
telco64 (58), -- TELCO 64
|
|
irEthQN (59),
|
|
none (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connector of the port/interface.
|
|
other - none of the specified connectors
|
|
none - no connector."
|
|
::= { physicalConnectorEntry 2 }
|
|
|
|
portOptWaveLength OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
nm850(2),
|
|
nm1300(3),
|
|
nm1300Laser(4),
|
|
nm1550Laser(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wave Length of an Optical interface/port in [nm] and specification if
|
|
Laser or not.
|
|
notApplicable - for non-optical ports."
|
|
::= { physicalConnectorEntry 3 }
|
|
|
|
portOptMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
singleMode(2),
|
|
multiMode(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Laser Mode of an Optical Laser interface/port.
|
|
notApplicable - for non-Laser ports."
|
|
::= { physicalConnectorEntry 4 }
|
|
|
|
portBalance OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
unbalanced (2),
|
|
balanced (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is according to the port Impedance.
|
|
For T1 - always balanced.
|
|
For E1 - there are different impedance values for balanced
|
|
and unbalanced."
|
|
::= { physicalConnectorEntry 5 }
|
|
|
|
|
|
prtSupervisory OBJECT IDENTIFIER ::= { systemPort 2 }
|
|
|
|
|
|
prtSpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {prtSupervisory 1}
|
|
|
|
prtSpEntry OBJECT-TYPE
|
|
SYNTAX PrtSpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Supervisory port parameter table."
|
|
INDEX {prtSupervisoryIndex }
|
|
::= { prtSpTable 1}
|
|
|
|
PrtSpEntry ::=
|
|
SEQUENCE {
|
|
prtSupervisoryIndex Integer32,
|
|
prtSupervisoryRate INTEGER,
|
|
prtSupervisoryDataBits INTEGER,
|
|
prtSupervisoryParity INTEGER,
|
|
prtSupervisoryStopBits INTEGER,
|
|
prtSupervisoryUsage INTEGER,
|
|
prtSupervisoryInterface INTEGER,
|
|
prtSupervisoryCTS INTEGER,
|
|
prtSupervisoryDcdDelay INTEGER,
|
|
prtSupervisoryDSR INTEGER,
|
|
prtSupervisoryRoutProtocol INTEGER
|
|
}
|
|
|
|
prtSupervisoryIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SP port index.
|
|
For some products, having modules (cards):
|
|
The LS byte of the integer is the port index 1..255.
|
|
The MS byte is different than 0 only if the port belongs to
|
|
a module. In that case it is the module number.
|
|
For other products' index see their specification."
|
|
::= { prtSpEntry 1}
|
|
|
|
prtSupervisoryRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto (1),
|
|
s300bps (2),
|
|
s1200bps (3),
|
|
s2400bps (4),
|
|
s4800bps (5),
|
|
s9600bps (6),
|
|
s19200bps (7),
|
|
s38400bps (8),
|
|
s57600bps (9),
|
|
s115200bps (10)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the operation rate (speed) of the
|
|
port.
|
|
auto - automatic rate selection, by the agent."
|
|
::= { prtSpEntry 2}
|
|
|
|
prtSupervisoryDataBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dataBits7 (1),
|
|
dataBits8 (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the number of data bits in an async
|
|
frame"
|
|
::= { prtSpEntry 3}
|
|
|
|
prtSupervisoryParity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
odd (2),
|
|
even (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the parity mode in an async frame"
|
|
::= { prtSpEntry 4}
|
|
|
|
prtSupervisoryStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
stopBits1 (2),
|
|
stopBits1dot5 (3),
|
|
stopBits2 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the parity mode in an async frame."
|
|
::= { prtSpEntry 5}
|
|
|
|
prtSupervisoryUsage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
noUse (2),
|
|
terminal(3),
|
|
nmsSlip (4),
|
|
nmsPpp (5),
|
|
muxSlip (6),
|
|
muxPpp (7),
|
|
dialOut (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the usage of the SP port."
|
|
::= { prtSpEntry 6}
|
|
|
|
prtSupervisoryInterface OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
dce (2),
|
|
dte (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the supervisory port interface."
|
|
::= { prtSpEntry 7}
|
|
|
|
prtSupervisoryCTS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
on (2), --Old value for DCE.
|
|
rts (3), --Old value for DCE
|
|
dteWait (4), --DTE will wait for CTS to become active before transmit date.
|
|
dteIgnore (5) --DTE will Ignore CTS signal and will transmit date anyway.
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CTS line state."
|
|
::= { prtSpEntry 8}
|
|
|
|
prtSupervisoryDcdDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
d0 (2),
|
|
d10 (3),
|
|
d50 (4),
|
|
d100 (5),
|
|
d200 (6),
|
|
d300 (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DCD delay in msec."
|
|
::= { prtSpEntry 9}
|
|
|
|
prtSupervisoryDSR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
on (2),
|
|
dtr (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSR line state."
|
|
::= { prtSpEntry 10}
|
|
|
|
prtSupervisoryRoutProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
proprietary (3),
|
|
rip2 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the routing protocol of the port.
|
|
notApplicable - for DP."
|
|
::= { prtSpEntry 11}
|
|
|
|
--Port Performance Data
|
|
|
|
prtPerformance OBJECT IDENTIFIER ::= { systemPort 3 }
|
|
|
|
prtPerfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtPerfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes G.826 ports or interfaces."
|
|
::= {prtPerformance 1}
|
|
|
|
prtPerfEntry OBJECT-TYPE
|
|
SYNTAX PrtPerfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtPerfIdx, prtPerfPeriodRef}
|
|
::= { prtPerfTable 1 }
|
|
|
|
PrtPerfEntry ::=
|
|
SEQUENCE {
|
|
prtPerfIdx
|
|
Integer32,
|
|
prtPerfPeriodRef
|
|
INTEGER,
|
|
prtPerfElapsedTime
|
|
Integer32,
|
|
prtPerfUAS
|
|
Integer32,
|
|
prtPerfES
|
|
Integer32,
|
|
prtPerfSES
|
|
Integer32,
|
|
prtPerfBBE
|
|
Integer32,
|
|
prtPerfBlocksPerSec
|
|
Integer32,
|
|
prtPerfTimeTag
|
|
TimeTicks,
|
|
prtPerfSaveAndResetCmd
|
|
INTEGER
|
|
}
|
|
|
|
prtPerfIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index of the specific port or interface.
|
|
For a port, the index will be as agreed between agent and
|
|
application.
|
|
For an interface, ifIndex may be used."
|
|
::= { prtPerfEntry 1 }
|
|
|
|
prtPerfPeriodRef OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
currentPeriod (1),
|
|
lastPeriod (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index that specifies which period of time, the next
|
|
5 objects refer to.
|
|
currentPeriod - the period since last prtPerfSaveAndResetCmd received or
|
|
since Start-up (if no prtPerfSaveAndResetCmd was received since
|
|
Start-up) until now.
|
|
lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd.
|
|
- If only one command occured since Start-up: the period between
|
|
Start-up and last command.
|
|
- If no command occured since Start-up: this period will not
|
|
actually exist. In this case, he following 5 objects will be 0."
|
|
::= { prtPerfEntry 2 }
|
|
|
|
prtPerfElapsedTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Elapsed Time in seconds.
|
|
- for prtPerfPeriodRef=currentPeriod:
|
|
The period since last prtPerfSaveAndResetCmd received or since Start-up
|
|
(if no prtPerfSaveAndResetCmd was received since Start-up) until now.
|
|
- for prtPerfPeriodRef=lastPeriod:
|
|
The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd
|
|
was received."
|
|
::= { prtPerfEntry 3 }
|
|
|
|
prtPerfUAS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Unavailable Seconds for the reference period (prtPerfPeriodRef)."
|
|
::= { prtPerfEntry 4 }
|
|
|
|
prtPerfES OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Errored Seconds for the reference period (prtPerfPeriodRef)."
|
|
::= { prtPerfEntry 5 }
|
|
|
|
prtPerfSES OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef)."
|
|
::= { prtPerfEntry 6 }
|
|
|
|
prtPerfBBE OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Background Block (or Frame) Errors for the reference period
|
|
(prtPerfPeriodRef)."
|
|
::= { prtPerfEntry 7 }
|
|
|
|
prtPerfBlocksPerSec OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Blocks per second (or frames per second) of the port/interface indicated by
|
|
portIdx. This object is constant for a certain port/interface.
|
|
It is not affected by the prtPerfPeriodRef index."
|
|
::= { prtPerfEntry 8 }
|
|
|
|
prtPerfTimeTag OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was
|
|
executed.
|
|
This object is applicable only for prtPerfPeriodRef=lastPeriod.
|
|
For prtPerfPeriodRef=currentPeriod, the value will always be 0."
|
|
::= { prtPerfEntry 9 }
|
|
|
|
prtPerfSaveAndResetCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A command per port/interface, to Save data of Current Period in Last Period
|
|
data-set and start a new counting period for Current Period.
|
|
This object is applicable only for prtPerfPeriodRef=currentPeriod.
|
|
Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent
|
|
to return: Bad Value response.
|
|
When setting validly this object to on(3), agent will perform the required
|
|
command and will reset automatically the value of this object to off(2).
|
|
Setting this object to off(2), will do nothing."
|
|
::= { prtPerfEntry 10 }
|
|
|
|
--Port Test Data
|
|
|
|
prtTest OBJECT IDENTIFIER ::= { systemPort 4 }
|
|
|
|
prtTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes test data for ports or interfaces."
|
|
::= {prtTest 1}
|
|
|
|
prtTestEntry OBJECT-TYPE
|
|
SYNTAX PrtTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtTestIdx}
|
|
::= { prtTestTable 1 }
|
|
|
|
PrtTestEntry ::=
|
|
SEQUENCE {
|
|
prtTestIdx
|
|
Integer32,
|
|
prtTestCmdAndStatus
|
|
Integer32,
|
|
prtBertCounter
|
|
Integer32,
|
|
prtTestInitiator
|
|
INTEGER,
|
|
prtTestTimeout
|
|
Integer32
|
|
}
|
|
|
|
prtTestIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index of the specific port or interface.
|
|
For a port, the index will be as agreed between agent and
|
|
application.
|
|
For an interface, ifIndex may be used."
|
|
::= { prtTestEntry 1 }
|
|
|
|
prtTestCmdAndStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to a value as detailed further on
|
|
(except 0) will initiate a test on the specific port.
|
|
The test/s requested will be set according to the respective
|
|
bit. The value of this object will be a sum of (2**n), where n is
|
|
the Bit:
|
|
TEST BIT VALUE
|
|
----------- --- ------
|
|
reserved 0 1
|
|
PayloadLoop=RLB 1 (=Remote Loopback) 2
|
|
LineLoop=DIG 2 (=Digital) 4
|
|
OtherLoop 3 8
|
|
InwardLoop=LLB 4 (=Local Loopback) 16
|
|
BERT 5 32
|
|
LC 6 64
|
|
ToneInjection 7 128
|
|
Inband 8 256
|
|
|
|
e.g : If the requested value is 20 -> 010100 ->
|
|
Bits 2 & 4 are set -> the requested tests are :
|
|
LineLoopback=DIG
|
|
InwardLoopback=LLB
|
|
|
|
Not all tests combinations are valid.
|
|
For valid test combination, see each product's specification.
|
|
For LRS52, only single test is allowed simultaneously
|
|
|
|
The terminology and order of the first tests (except BERT)
|
|
is according to the one used for Test Status of DS1 and DS3 standards.
|
|
The notations : RLB, LLB, DIG are the most used in RAD's products, but they
|
|
can be different. For exact definition see product's spec.
|
|
|
|
Setting this object to stop (value=0 ; all bits are 0),
|
|
will stop all the user requested tests running on the
|
|
selected port.
|
|
|
|
When no test is running on the port, the Get value (test status)
|
|
will be 0.
|
|
|
|
PayloadLoop=RLB
|
|
The received signal at this interface is looped
|
|
through the device. Typically the received signal
|
|
is looped back for retransmission after it has
|
|
passed through the device's framing function.
|
|
|
|
LineLoop=DIG
|
|
The received signal at this interface does not
|
|
go through the device (minimum penetration) but
|
|
is looped back out.
|
|
|
|
OtherLoop
|
|
Loopbacks that are not defined here.
|
|
|
|
InwardLoop=LLB
|
|
The sent signal at this interface is looped back
|
|
through the device.
|
|
|
|
LC
|
|
This loop is applicable only for HSSI interface, towards the router .
|
|
|
|
ToneInjection
|
|
This loop is applicable for analog voice (like FXS)."
|
|
|
|
::= { prtTestEntry 2 }
|
|
|
|
prtBertCounter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of BERT errors encountered
|
|
during the BERT operation.
|
|
It is valid only when BERT (Bit Error Rate Test) is active on the
|
|
specific port.
|
|
The Counter starts from zero (0) anytime BERT is initiated."
|
|
::= { prtTestEntry 3}
|
|
|
|
prtTestInitiator OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
user (2),
|
|
remoteUnit(3),
|
|
dteRouter (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates who initiated this port's test/s."
|
|
::= { prtTestEntry 4 }
|
|
|
|
prtTestTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..4095)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only when a single
|
|
test is running. It indicates the test
|
|
activation timeout in minutes.
|
|
When the timeout expires, the test is stopped.
|
|
Value of 0 indicates test may run Forever "
|
|
::= { prtTestEntry 5 }
|
|
|
|
--Port General Parameters
|
|
|
|
prtParam OBJECT IDENTIFIER ::= { systemPort 5 }
|
|
|
|
prtParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes general port parameters. The meaning is
|
|
different for every product that supports it due to a general
|
|
parameter - prtControlCnfg.
|
|
|
|
For ACE2002:
|
|
-This table is used as a mechanism to create the next interface index.
|
|
The algorithm description:
|
|
The NMS will send the agent the following get command: get(nextIfIndex.index),
|
|
where index=interface on which the new index is dependent on.
|
|
Upon this command the agent will generate and return the new index to the NMS.
|
|
- This table is partially supported according to the interface type.
|
|
Upon getNext function the irrelevant parameters will be skipped."
|
|
::= {prtParam 1}
|
|
|
|
prtParamEntry OBJECT-TYPE
|
|
SYNTAX PrtParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtParamIdx}
|
|
::= { prtParamTable 1 }
|
|
|
|
PrtParamEntry ::=
|
|
SEQUENCE {
|
|
prtParamIdx
|
|
Integer32,
|
|
prtControlCnfg
|
|
Integer32,
|
|
prtParamClkSrc
|
|
INTEGER,
|
|
prtParamPhantom
|
|
INTEGER,
|
|
prtParamResetStatsCmd
|
|
INTEGER,
|
|
prtParamLastResetStatsTime
|
|
TimeStamp,
|
|
prtParamInterfaceType
|
|
INTEGER,
|
|
prtParamClearAlarm
|
|
INTEGER,
|
|
prtParamLeds
|
|
OCTET STRING
|
|
}
|
|
|
|
prtParamIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index of the specific port or interface.
|
|
For a port, the index will be as agreed between agent and
|
|
application.
|
|
For an interface, ifIndex may be used.
|
|
|
|
For ACE2002:
|
|
This parameter is the physical layer ifIndex of the slot on
|
|
which the NMS requires the next interface index."
|
|
::= { prtParamEntry 1 }
|
|
|
|
prtControlCnfg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object may be used for port RW general parameter/s.
|
|
For detailed meaning, see product's spec.
|
|
Supported by: PRBi-E3/T3.
|
|
|
|
For ACE2002:
|
|
This parameter will include the value of the new index
|
|
generated by agent.
|
|
|
|
For Optimux-T3 and OP-155-1:
|
|
This parameter will be used for Release Remote LLB Command:
|
|
on=2= Set value only. Command to release LLB of Remote Unit.
|
|
Agent will return automatically to 'off' value after performing
|
|
the command.
|
|
off=3=Get value only.
|
|
|
|
|
|
For LA140
|
|
This parameter will be used as EchoCanceler per timeslot
|
|
off = 2 Echo Canceler is disabled
|
|
on = 3 Echo Canceler is enabled
|
|
|
|
For FCD-155
|
|
This parameter will be used to select the port that is
|
|
clock source for a PDH port, when 2495.dsx1TransmitClockSource=throughTiming.
|
|
VC12/VT1.5 = 2
|
|
SDH/SONET = 3
|
|
|
|
For ACE-52
|
|
This parameter will be used as Transmit Frame Type, i.e.
|
|
which type of frame the corresponding bridge port will transmit:
|
|
Untagged = 2
|
|
Tagged = 3
|
|
."
|
|
::= { prtParamEntry 2 }
|
|
|
|
prtParamClkSrc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
loopTiming (1),
|
|
localTiming (2),
|
|
throughTiming (3),
|
|
adaptive (4),
|
|
master (5),
|
|
fallback (6),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source of Transmit Clock.
|
|
'loopTiming' or 'loopback' indicates that the recovered receive clock
|
|
is used as the transmit clock.
|
|
|
|
'localTiming' or 'internal' indicates that a local clock
|
|
source is used or when an external clock is
|
|
attached to the box containing the interface.
|
|
|
|
'throughTiming' or 'external' indicates that recovered receive clock
|
|
from another card or interface is used as the transmit clock.
|
|
|
|
'adaptive' indicates that the clock is recovered according
|
|
to the received data flow rate.
|
|
|
|
'master' and 'fallback' values may be used RO to
|
|
indicate active clock."
|
|
::= { prtParamEntry 3 }
|
|
|
|
|
|
prtParamPhantom OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power feeding to another device."
|
|
::= { prtParamEntry 4 }
|
|
|
|
prtParamResetStatsCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset statistics of the selected port."
|
|
::= { prtParamEntry 5 }
|
|
|
|
prtParamLastResetStatsTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of MIB II's sysUpTime object at the last time that
|
|
prtParamResetStatsCmd was Set to on(3) for this port.
|
|
If prtParamResetStatsCmd was never Set to on(3) since last
|
|
re-initialization of the agent, then this object contains a zero value.
|
|
This object enables calculating the running time of Statistics
|
|
counters for this port, by: [sysUpTime-prtParamLastResetStatsTime].
|
|
For some devices other types of 'Reset' may affect this parameter"
|
|
::= { prtParamEntry 6 }
|
|
|
|
prtParamInterfaceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
e1 (2),
|
|
t1 (3),
|
|
fr (4),
|
|
hdlc (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the port."
|
|
::= { prtParamEntry 7 }
|
|
|
|
prtParamClearAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce a clear
|
|
operation on the Port Alarms.
|
|
Upon completion, the value will automatically change
|
|
to off(2)."
|
|
::= { prtParamEntry 8 }
|
|
|
|
prtParamLeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry specifies the LEDs status of the port.
|
|
Each led is represented by 4 bits where the first 2 bits
|
|
(left) specify the status :
|
|
(00=NA, 01=OFF, 10=ON, 11=BLINK),
|
|
and the next two bits (right) specify the color :
|
|
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY).
|
|
The order of the LEDS is from top to bottom, left to right:
|
|
For each row starting from the top,
|
|
the LEDS are returned from left to right."
|
|
::= {prtParamEntry 9}
|
|
|
|
|
|
prtIP OBJECT IDENTIFIER ::= { systemPort 6 }
|
|
|
|
prtIpParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtIpParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table - Parameters for IP Ports."
|
|
::= {prtIP 1}
|
|
|
|
prtIpParamEntry OBJECT-TYPE
|
|
SYNTAX PrtIpParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtIpParamConfigIdx, prtIpParamSlotIdx, prtIpParamIdx }
|
|
::= { prtIpParamTable 1 }
|
|
|
|
PrtIpParamEntry ::=
|
|
SEQUENCE {
|
|
prtIpParamConfigIdx Integer32,
|
|
prtIpParamSlotIdx Integer32,
|
|
prtIpParamIdx Integer32,
|
|
prtIpParamHostIP IpAddress,
|
|
prtIpParamHostMask IpAddress,
|
|
prtIpParamDefaultGateway IpAddress,
|
|
prtIpParamMediaMode INTEGER,
|
|
prtIpParamMediaRate INTEGER,
|
|
prtIpParamMngVlanSupport INTEGER,
|
|
prtIpParamMngVlanId Integer32,
|
|
prtIpParamMngVlanPriority Integer32,
|
|
prtIpParamRingMode INTEGER,
|
|
prtIpParamProtIpEnable INTEGER,
|
|
prtIpParamTrafficPriority INTEGER,
|
|
prtIpParamRemoteIP IpAddress,
|
|
prtIpParamMaxTxBandwidth INTEGER
|
|
}
|
|
|
|
prtIpParamConfigIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Configuration number (1..255)
|
|
referred.
|
|
Value of 255 specifies the TmpCnfg (Scratch).
|
|
For products having Agent and Edit configurations,
|
|
Write operation for the table entries is allowed only to
|
|
Config=255."
|
|
::= { prtIpParamEntry 1 }
|
|
|
|
prtIpParamSlotIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique number of the slot position
|
|
in which the module is inserted.
|
|
notApplicable = 255 (for products that don't have slots).
|
|
|
|
For KM:
|
|
kmxMlA (103),
|
|
kmxMlB (104)."
|
|
::= { prtIpParamEntry 2 }
|
|
|
|
prtIpParamIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique Port Index."
|
|
::= { prtIpParamEntry 3 }
|
|
|
|
prtIpParamHostIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The host interface IP address."
|
|
::= { prtIpParamEntry 4 }
|
|
|
|
prtIpParamHostMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The host interface subnet mask."
|
|
::= { prtIpParamEntry 5 }
|
|
|
|
prtIpParamDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Gateway's IP Address."
|
|
::= { prtIpParamEntry 6 }
|
|
|
|
prtIpParamMediaMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
halfDuplex (2),
|
|
fullDuplex (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the real Media Mode."
|
|
::= { prtIpParamEntry 7 }
|
|
|
|
prtIpParamMediaRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
r10Mbps (2),
|
|
r100Mbps (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the real Media Rate (Mbps)."
|
|
::= { prtIpParamEntry 8 }
|
|
|
|
prtIpParamMngVlanSupport OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management VLAN support (Tagging).
|
|
no - No support of VLAN Tagging.
|
|
yes - 4 VLAN bytes will be added to the frame."
|
|
::= { prtIpParamEntry 9 }
|
|
|
|
prtIpParamMngVlanId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management VLAN ID."
|
|
::= { prtIpParamEntry 10 }
|
|
|
|
prtIpParamMngVlanPriority OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management VLAN Frame priority."
|
|
::= { prtIpParamEntry 11 }
|
|
|
|
prtIpParamRingMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates If Ring Mode is enabled or not."
|
|
::= { prtIpParamEntry 12 }
|
|
|
|
prtIpParamProtIpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether a list of Protected IP Addresses
|
|
is enabled or not. This object is applicable only if
|
|
prtIpParamRingMode=enable."
|
|
::= { prtIpParamEntry 13 }
|
|
|
|
prtIpParamTrafficPriority OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
low (2),
|
|
high (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the traffic priority of this port."
|
|
::= { prtIpParamEntry 14 }
|
|
|
|
prtIpParamRemoteIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the IP Address of the remote device that is connected to the
|
|
current device (Point to Point Application). It is used for sending OAM packets
|
|
on the LAN to the remote side in order to check that the connection is OK."
|
|
::= { prtIpParamEntry 15 }
|
|
|
|
|
|
prtIpParamMaxTxBandwidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (2),
|
|
e1 (3),
|
|
t1 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the Max Bandwidth allowed on the LAN.
|
|
Full - means that a Maximum of 100 Mega Byte Rate may go through the LAN.
|
|
e1(3) means that the maximum is an E1 rate. t1(4) is for a maximum of a T1 rate."
|
|
::= { prtIpParamEntry 16 }
|
|
|
|
|
|
|
|
prtClkSrc OBJECT IDENTIFIER ::= { systemPort 7 }
|
|
|
|
prtClkSrcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtClkSrcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table - Parameters for master and fallback
|
|
clock source of ports ."
|
|
::= {prtClkSrc 1}
|
|
|
|
prtClkSrcEntry OBJECT-TYPE
|
|
SYNTAX PrtClkSrcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtClkSrcCnfgIdx, prtClkSrcPrtIdx, prtClkSrcIdx}
|
|
::= { prtClkSrcTable 1}
|
|
|
|
PrtClkSrcEntry ::=
|
|
SEQUENCE {
|
|
prtClkSrcCnfgIdx Integer32,
|
|
prtClkSrcPrtIdx Integer32,
|
|
prtClkSrcIdx INTEGER,
|
|
prtClkSrcMode INTEGER,
|
|
prtClkSrcPrt Integer32
|
|
}
|
|
|
|
prtClkSrcCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..255) being
|
|
accessed ; Idx of 255 relates to the TmpCnfg."
|
|
::= { prtClkSrcEntry 1}
|
|
|
|
prtClkSrcPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique Port Index (receiving clock).
|
|
Refer to device specification for port Index"
|
|
::= { prtClkSrcEntry 2}
|
|
|
|
prtClkSrcIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master (1),
|
|
fallback (2)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index in the table.
|
|
master - refers Master clock parameters
|
|
fallback - refers Fallback clock parameters"
|
|
::= { prtClkSrcEntry 3}
|
|
|
|
prtClkSrcMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
-- none (1),
|
|
internal (2),
|
|
rxClk (3),
|
|
-- station (4),
|
|
-- lbt (5),
|
|
-- ntr (6),
|
|
-- adaptive (7),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the source the nodal timing is
|
|
locked to. "
|
|
::= { prtClkSrcEntry 4}
|
|
|
|
prtClkSrcPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is valid only when working in rxClk mode.
|
|
It specifies the port from which the clock willl be taken.
|
|
Refer to device specification for source port Index"
|
|
::= { prtClkSrcEntry 5}
|
|
|
|
|
|
systemResetAllStatsCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset statistics of all ports and connections of the device."
|
|
::= { agnt 16 }
|
|
|
|
systemClearTablesCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
tempCnfgTables (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tempCnfgTables - Set *RowStatus = destroy for all entries of
|
|
some tables having *RowStatus object, for
|
|
temporary configuration only! (255).
|
|
For the relevant tables, see product's specification.
|
|
This object should be used by WAN product applications
|
|
before performing the Update operation, in order to clear
|
|
old entries of these tables.
|
|
For MP-104/204 the entries will be destroyed for cnfg=1.
|
|
off - agent will automatically change to this value, after performing the
|
|
command. "
|
|
::= { agnt 17 }
|
|
|
|
systemParameter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter can be used for different purposes:
|
|
- TELNET session time-out in seconds.
|
|
- Ace20: when trying to create row in a table that already
|
|
has row with the same values, if set of values has to be unique
|
|
in table, this attribute is set to the index of the existing row.
|
|
- Optimux-T3: when CH interfaces are RJ-45, user can select via this
|
|
object, the interface type for each Group of channels: T1 or E1:
|
|
The selection will be a sum of the following Bits.
|
|
'0' = T1
|
|
'1' = E1
|
|
Bit Group Value for each Bit having '1'
|
|
1 1 (CH-1..CH-8) 1
|
|
2 2 (CH-9..CH-12) 2
|
|
3 3 (CH-13..CH-20) 4
|
|
4 4 (CH-21..CH-28) 8
|
|
Examples:
|
|
15 = all Groups are selected to be E1
|
|
6 = Group 2 and Group 3 are selected to be E1
|
|
(Group 1 and Group 4 are T1).
|
|
- FCD-A, FCD-M: user can select via this object the configuration
|
|
used for Get values of MSDSL parameters that don't have
|
|
configuration index.
|
|
1 =active configuration
|
|
255=temporary configuration.
|
|
Set of this object should be done before Getting the MSDSL
|
|
RW parameters.
|
|
- Ace2002: This parameter indicates the number of intervals that
|
|
were successfully uploaded upon statistics collection session.
|
|
- FCD-IP, WR, FCD-IPD, LA-240:
|
|
This parameter indicates whether Telnet Access is enabled/disabled:
|
|
Values:
|
|
2 - Telnet Access is Disabled.
|
|
3 - Telnet Access is Enabled.
|
|
-Vmux-110: This parameter value equals to maximum number of bundles.
|
|
-Optimux-155: Simmilar usage to Optimux T3. user can select via this
|
|
object, interface type T1 or E1 for each Group of
|
|
channels (LIU): LIU group consists of 7 channels.
|
|
Up to 12 LIUs are represented (84 T1 Channels).
|
|
The selection will be a sum of the 2**n
|
|
For each bit:'0' = T1 ,'1' = E1
|
|
Bit Group
|
|
1 1 (CH-1 .. CH-7)
|
|
2 2 (CH-8 .. CH-14)
|
|
3 3 (CH-15 ..CH-21)
|
|
...
|
|
9 9 (CH-56.. CH-63)
|
|
...
|
|
10 10 (CH-64..CH-70)
|
|
11 11 (CH-71..CH-77)
|
|
12 12 (CH-78..CH-84) "
|
|
::= { agnt 18 }
|
|
|
|
|
|
agnGlobalAlarmMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this attribute determines the alarm traps the
|
|
agent should mask and not send to the managers.
|
|
Each bit from a certain octet represents a certain alarm."
|
|
::= { agnt 19 }
|
|
|
|
alarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the severity of the alarms."
|
|
::= { agnt 20 }
|
|
|
|
alarmState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2), -- End,
|
|
on (3) -- Start.
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { agnt 21 }
|
|
|
|
|
|
agnTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current test status (for all levels: system,
|
|
card, port).
|
|
This attribute will be set to:
|
|
on(3): when there is at least one test in progress on the
|
|
system/card/port
|
|
off(2): when there is NO test in progress on the
|
|
system/card/port"
|
|
::= {agnt 22 }
|
|
|
|
systemSaveAndResetAllStatsCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"on - a command to Save data of Current Period in Last Period
|
|
data-set and start a new counting period for Current Period.
|
|
off - agent will automatically change to this value, after performing the
|
|
command."
|
|
::= { agnt 23 }
|
|
|
|
systemDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Gateway's IP Address."
|
|
::= { agnt 24 }
|
|
|
|
-- PS Table
|
|
systemPsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SystemPsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes the PS types of a device.
|
|
Usage of this table is specified in the device's NMS SRS"
|
|
::= { agnt 25 }
|
|
|
|
systemPsEntry OBJECT-TYPE
|
|
SYNTAX SystemPsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {systemPsIndex1, systemPsIndex2}
|
|
::= { systemPsTable 1 }
|
|
|
|
SystemPsEntry ::=
|
|
SEQUENCE {
|
|
systemPsIndex1
|
|
Integer32,
|
|
systemPsIndex2
|
|
Integer32,
|
|
systemPsType
|
|
INTEGER,
|
|
systemPsStatus
|
|
INTEGER,
|
|
systemPsHotSwap
|
|
INTEGER
|
|
}
|
|
|
|
systemPsIndex1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First Index.
|
|
In HUBs:
|
|
1 = PS-A slot
|
|
2 = PS-B slot.
|
|
In SA units:
|
|
1 = PS1
|
|
2 = PS2
|
|
Default = 1"
|
|
::= { systemPsEntry 1 }
|
|
|
|
systemPsIndex2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Second Index.
|
|
In HUBs:
|
|
1 always.
|
|
In SA units:
|
|
1 = Local
|
|
2 = Remote
|
|
Default = 1."
|
|
::= { systemPsEntry 2 }
|
|
|
|
systemPsType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
ac (2),
|
|
dc (3),
|
|
acDc (4),
|
|
acPF (5),
|
|
dcPF (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of PS, for a stand-alone product.
|
|
acDc - AC with rj45 DC.
|
|
acPF - Power Feeding (phantom) box that is feeding another box by external AC.
|
|
dcPF - Power Feeding (phantom) box that is feeding another box by external DC."
|
|
::= { systemPsEntry 3 }
|
|
|
|
systemPsStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
failed (2),
|
|
ok (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Status of the PS unit."
|
|
::= { systemPsEntry 4 }
|
|
|
|
systemPsHotSwap OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
fixed (2),
|
|
hotSwap (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is PS unit hot swap or fixed."
|
|
::= { systemPsEntry 5 }
|
|
|
|
agnFans OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry specifies the FANs existence and status.
|
|
Each fan will be represented by 2 bits,
|
|
where the first bit (right) will specify the existence:
|
|
(0= Not exist, 1=exist),
|
|
and the left bit will specify it's status
|
|
(0= OK, 1=FAIL), so for each fan:
|
|
00 - FAN does not exist
|
|
01 - FAN exists and OK
|
|
11 - FAN exists and is Failed
|
|
bits 0-1 are for first fan
|
|
bits 2-3 are for 2nd fan (if exists)."
|
|
::= { agnt 26 }
|
|
|
|
agnSendTrapParameter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies if the agent will attach a specific
|
|
parameter to a trap.
|
|
|
|
For ACE2002 the agent will attach or not the openViewSeverity
|
|
parameter according to the value of this parameter:
|
|
1 - will attach openViewSeverity.
|
|
0 - will not attach openViewSeverity."
|
|
::= { agnt 27 }
|
|
|
|
agnSensorsStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry specifies the Sensors (Temperature sensors or others)
|
|
existence and status.
|
|
Each sensor will be represented by 2 bits,
|
|
where the first bit (right) will specify the existence:
|
|
(0= Not exist, 1=exist),
|
|
and the left bit will specify it's status
|
|
(0= OK, 1=FAIL), so for each sensor:
|
|
00 - sensor does not exist
|
|
01 - sensor exists and status is OK
|
|
11 - sensor exists and status is not OK
|
|
( e.g. temperature exceeds pre-defined threshold)
|
|
bits 0-1 are for first sensor
|
|
bits 2-3 are for 2nd sensor (if exists)
|
|
and so on...
|
|
Bit 0 is the LSB."
|
|
::= { agnt 28 }
|
|
|
|
agnStationClockCard OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
notExist (2),
|
|
notValid (3),
|
|
ok (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry specifies the station clock card
|
|
existence and status.
|
|
notExist - station clock card (piggy) does not exist.
|
|
notValid - station clock card exists but clock status is not valid.
|
|
ok - station clock card exists, and its status is OK "
|
|
::= { agnt 29 }
|
|
|
|
xcIndexNext OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains an appropriate value to
|
|
be used for xcIndex when creating
|
|
entries in the xcTable. The value
|
|
0 indicates that no unassigned entries are
|
|
available. To obtain the xcIndex
|
|
value for a new entry, the manager issues a
|
|
management protocol retrieval operation to obtain
|
|
the current value of this object. After each
|
|
retrieval, the agent should modify the value to
|
|
the next unassigned index.
|
|
After a manager retrieves a value the agent will
|
|
determine through its local policy when this index
|
|
value will be made available for reuse."
|
|
::= { agnt 30 }
|
|
|
|
--XC Table
|
|
xcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF XcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration of system cross-connect entries.
|
|
The table follows the behavior described in RFC 2515,
|
|
RFC 1604 regarding the creation deletion and modification
|
|
of an entry within the table."
|
|
::= { agnt 31 }
|
|
|
|
xcEntry OBJECT-TYPE
|
|
SYNTAX XcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { xcIndex, xcIfIndex1, xcVpi, xcVci, xcIfIndex2 }
|
|
::= { xcTable 1}
|
|
|
|
XcEntry ::=
|
|
SEQUENCE {
|
|
xcIndex Integer32,
|
|
xcIfIndex1 Integer32,
|
|
xcVpi Integer32,
|
|
xcVci Integer32,
|
|
xcIfIndex2 Integer32,
|
|
xcRowStatus RowStatus,
|
|
xcDescr DisplayString,
|
|
xcAdminStatus INTEGER,
|
|
xcOperStatus INTEGER,
|
|
xcAttachedIfType INTEGER,
|
|
xcInputPriority Integer32,
|
|
xcBitMapping Integer32
|
|
}
|
|
|
|
xcIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cross Connect Identifier."
|
|
::= { xcEntry 1 }
|
|
|
|
xcIfIndex1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface Index from the ifTable, which identify one side
|
|
of the connection."
|
|
::= { xcEntry 2 }
|
|
|
|
xcVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI value."
|
|
::= { xcEntry 3 }
|
|
|
|
xcVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI value."
|
|
::= { xcEntry 4 }
|
|
|
|
xcIfIndex2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface Index from the ifTable, which identifies the other
|
|
side of the connection."
|
|
::= { xcEntry 5 }
|
|
|
|
xcRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter allows NMS to create/delete entries of this table."
|
|
::= { xcEntry 6 }
|
|
|
|
xcDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information about the
|
|
xc entry."
|
|
::= { xcEntry 7 }
|
|
|
|
|
|
xcAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired administrative status of this bi-directional
|
|
cross-connect."
|
|
::= { xcEntry 8 }
|
|
|
|
xcOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational status of this bi-directional cross-connect."
|
|
::= { xcEntry 9 }
|
|
|
|
xcAttachedIfType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
free (2),
|
|
routerAtm (3),
|
|
lis (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if the specific VCC is
|
|
already attached to any interface, and indicates
|
|
the type of the interface.
|
|
This object's purpose is to ease the checking to
|
|
the NMS.
|
|
notApplicable - used for entries that are not LAN (as HDLC),
|
|
or when the VCC was attached to a bridge, or
|
|
when this parameter is irrelevant.
|
|
free - the LAN VCC wasn't attached yet to any router
|
|
interface.
|
|
routerAtm - attached to an ATM router interface.
|
|
lis - attached to a LIS interface."
|
|
::= { xcEntry 10 }
|
|
|
|
xcInputPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the priority, by which the LAN frames will be
|
|
internaly sent to the ATM HW. This parameter is applicable if
|
|
atmNteMdlInputPriorityMechanism=enabled.
|
|
|
|
1 - Highest priority. Will be the first to be sent to the ATM HW.
|
|
4 - Lowest priority. Will be the last to be sent to the ATM HW."
|
|
::= { xcEntry 11 }
|
|
|
|
xcBitMapping OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object maps this entry to a bit of an octet string.
|
|
For ACE2002 this object maps the LAN VCC to the bit of the
|
|
VLAN Port Lists. If the value is '0' then it means that
|
|
this VCC is not mapped to a port list or it may be an HDSL
|
|
entry."
|
|
::= { xcEntry 12 }
|
|
|
|
systemModule OBJECT IDENTIFIER ::= { agnt 32 }
|
|
|
|
|
|
modlParam OBJECT IDENTIFIER ::= { systemModule 1 }
|
|
|
|
modlParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ModlParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table include parameters for system modules."
|
|
::= { modlParam 1 }
|
|
|
|
modlParamEntry OBJECT-TYPE
|
|
SYNTAX ModlParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { modlParamIndex }
|
|
::= { modlParamTable 1}
|
|
|
|
|
|
ModlParamEntry ::=
|
|
SEQUENCE {
|
|
modlParamIndex Integer32,
|
|
modlParamReset INTEGER,
|
|
modlParamSwdlStatus INTEGER,
|
|
modlParamLeds OCTET STRING
|
|
}
|
|
|
|
modlParamIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The module index.
|
|
The index can be the slot number or any other module index as described
|
|
in the specifications of the device.
|
|
For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4."
|
|
::= { modlParamEntry 1 }
|
|
|
|
modlParamReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
on (3),
|
|
factory (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset action to be performed on the module.
|
|
Set the parameter will be done always to on(3) or factory (4).
|
|
After performing the Reset operation, Agent will automatically set the parameter to off(2)."
|
|
::= { modlParamEntry 2 }
|
|
|
|
modlParamSwdlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
off (2),
|
|
inProcess (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whatever the swdl is in process or not."
|
|
::= {modlParamEntry 3}
|
|
|
|
modlParamLeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry specifies the LEDs status of the module.
|
|
Each led is represented by 4 bits where the first 2 bits (left) specify the status :
|
|
(00=NA, 01=OFF, 10=ON, 11=BLINK),
|
|
and the next two bits (right) specify the color :
|
|
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY).
|
|
The order of the LEDS is from top to bottom, left to right:
|
|
For each row starting from the top, the LEDS are returned from left to right."
|
|
::= {modlParamEntry 4}
|
|
|
|
agnNearFarConnection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disconnected (2),
|
|
connected (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter describes the connection between near-end and far-end agents."
|
|
::= { agnt 33 }
|
|
|
|
agnAccess OBJECT IDENTIFIER ::= {agnt 34}
|
|
|
|
agnTelnetAccess OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable (2),
|
|
enable (3),
|
|
managersOnly (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable accessing the device via Telnet.
|
|
|
|
disable - no one will be allowed to access the device via Telnet.
|
|
enable - all users are allowed Telnet Access.
|
|
managersOnly - Only manager stations listed in the manager's list are allowed."
|
|
::= { agnAccess 1 }
|
|
|
|
agnWebAccess OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable (2),
|
|
enable (3),
|
|
managersOnly (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable accessing the device via Web.
|
|
|
|
disable - no one will be allowed to access the device via Web.
|
|
enable - all users are allowed Web Access.
|
|
managersOnly - Only manager stations listed in the manager's list are allowed."
|
|
::= { agnAccess 2 }
|
|
|
|
|
|
|
|
systemInterface OBJECT IDENTIFIER ::= { agnt 35 }
|
|
|
|
SysIfEntityType ::= INTEGER
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This type defines the Entity Type.
|
|
-- The values existing in IANAifType MIB
|
|
-- should be taken from there only.
|
|
-- Additional values can be added, starting from 1000 decimal,
|
|
-- when necessary."
|
|
{
|
|
other(1),
|
|
ethernetLan(6),
|
|
atm(37),
|
|
fastEther(62), -- Fast Ethernet (100BaseT)
|
|
ipForward(142), -- Router
|
|
teLink(200),
|
|
bridge(209)
|
|
}
|
|
|
|
-- Interface Configuration Table
|
|
|
|
ifCreateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IfCreateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Interface Configuration Table.
|
|
This table enables to create inferfaces of Entities."
|
|
::= { systemInterface 1 }
|
|
|
|
ifCreateEntry OBJECT-TYPE
|
|
SYNTAX IfCreateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Interface Configuration table."
|
|
INDEX { ifCreateEntityType , ifCreateEntityIdx ,
|
|
ifCreateNumber }
|
|
::= { ifCreateTable 1 }
|
|
|
|
IfCreateEntry ::=
|
|
SEQUENCE {
|
|
ifCreateEntityType SysIfEntityType,
|
|
ifCreateEntityIdx Integer32,
|
|
ifCreateNumber Integer32,
|
|
ifCreateRowStatus RowStatus,
|
|
ifCreateType IANAifType,
|
|
ifCreateIndex Integer32
|
|
}
|
|
|
|
ifCreateEntityType OBJECT-TYPE
|
|
SYNTAX SysIfEntityType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Entity Type."
|
|
::= { ifCreateEntry 1 }
|
|
|
|
ifCreateEntityIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Entity Index."
|
|
::= { ifCreateEntry 2 }
|
|
|
|
ifCreateNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Interface Number."
|
|
::= { ifCreateEntry 3 }
|
|
|
|
ifCreateRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables the user to
|
|
create/delete entries in this table."
|
|
::= { ifCreateEntry 4 }
|
|
|
|
ifCreateType OBJECT-TYPE
|
|
SYNTAX IANAifType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Interface Type."
|
|
::= { ifCreateEntry 5 }
|
|
|
|
ifCreateIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the ifIndex of the created Interface."
|
|
::= { ifCreateEntry 6 }
|
|
|
|
systemOam OBJECT IDENTIFIER ::= { agnt 36 }
|
|
|
|
systemOamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SystemOamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OAM Configuration Table."
|
|
::= { systemOam 1 }
|
|
|
|
systemOamEntry OBJECT-TYPE
|
|
SYNTAX SystemOamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the OAM table."
|
|
INDEX { systemOamCnfgIdx }
|
|
::= { systemOamTable 1 }
|
|
|
|
SystemOamEntry ::=
|
|
SEQUENCE {
|
|
systemOamCnfgIdx Integer32,
|
|
systemOamFrequency Integer32,
|
|
systemOamTimeoutCycles Integer32
|
|
}
|
|
|
|
systemOamCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..255) being
|
|
accessed ; Idx of 255 relates to the TmpCnfg."
|
|
::= { systemOamEntry 1}
|
|
|
|
systemOamFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time in sec. between 2 OAM packets."
|
|
::= { systemOamEntry 2 }
|
|
|
|
systemOamTimeoutCycles OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No. of cycles the agent will send OAM packets without receiving a response
|
|
from the remote device before declaring that the connection to the remote side
|
|
is down - Time Out."
|
|
::= { systemOamEntry 3 }
|
|
|
|
bitMappingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BitMappingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table maps bits of an octet string to an interface.
|
|
For ACE-2002 this table is used to map bits of VLAN port lists
|
|
to LAN VCC's. This table is the opposite view of the xcTable for
|
|
xcBitMapping. It is used to ease the bit translation for the NMS."
|
|
::= { agnt 38 }
|
|
|
|
bitMappingEntry OBJECT-TYPE
|
|
SYNTAX BitMappingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in the table describes a correlation of a bit location to
|
|
an interface.
|
|
For ACE-2002 - Upon creation of a new LAN VCC the agent will add an
|
|
entry to this table that will define the bit location for that VCC."
|
|
INDEX { bitMappingLocation }
|
|
::= { bitMappingTable 1}
|
|
|
|
BitMappingEntry ::=
|
|
SEQUENCE {
|
|
bitMappingLocation Integer32,
|
|
bitMappingIndex Integer32
|
|
}
|
|
|
|
bitMappingLocation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bit location in an octet string."
|
|
::= { bitMappingEntry 1 }
|
|
|
|
bitMappingIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface index or any other index that should be mapped."
|
|
::= { bitMappingEntry 2 }
|
|
|
|
bitMappingView OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A view of the bitMappingTable in one object - each entry in the
|
|
biMappingTable will have the corresponding Bit of this object
|
|
(bitMappingLocation) = '1'.
|
|
For ACE-2002 it is used to describe all the existing LAN VCC's
|
|
So that the NMS can easily calculate which VCC's can be selected
|
|
as members for a VLAN, instead of reading all the bitMapping Table."
|
|
::= { agnt 39 }
|
|
|
|
|
|
|
|
--TRAPS
|
|
|
|
--NOTIFICATIONS
|
|
|
|
systemsEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for RAD products."
|
|
::= { systems 0 }
|
|
|
|
tftpStatusChangeTrap NOTIFICATION-TYPE
|
|
OBJECTS { tftpStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent whenever the status of tftp changed."
|
|
::= { systemsEvents 1 }
|
|
|
|
agnStatusChangeTrap NOTIFICATION-TYPE
|
|
OBJECTS {agnIndication }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent whenever the state of the entity the agent is
|
|
responsible for changed.
|
|
TDM devices will send agnTestStatus variable to indicate the current test status."
|
|
::= { systemsEvents 2 }
|
|
|
|
prtStatusChangeTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent whenever the state of a port changed.
|
|
Attached, will be parameter/s that indicate the new port status.
|
|
The attached variables will be specified in the specifications
|
|
of the products supporting this trap."
|
|
::= { systemsEvents 3 }
|
|
|
|
swdlStatusResult NOTIFICATION-TYPE
|
|
OBJECTS {swdlStatusFileName}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when Software Down Load is finished.
|
|
The attached object indicates the File Name."
|
|
::= { systemsEvents 4 }
|
|
|
|
intSwdlSlotFileMismatch NOTIFICATION-TYPE
|
|
OBJECTS {intSwdlFileName}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when the card in the chosen slot doesn't match
|
|
the chosen file.
|
|
The attached object indicates the File Name."
|
|
::= { systemsEvents 5 }
|
|
|
|
agnCounterChange NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is sent when the value of a specific Counter is changed.
|
|
Agent can send as attached object the updated Counter.
|
|
For details about this Counter and attached object, see spec of the relevant
|
|
application."
|
|
::= { systemsEvents 6 }
|
|
|
|
prtClkSrcChangeTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon any port clock change."
|
|
::= { systemsEvents 7 }
|
|
|
|
moduleFailTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon a module failure."
|
|
::= { systemsEvents 8 }
|
|
|
|
moduleInitFailTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon a module initialization failure."
|
|
::= { systemsEvents 9 }
|
|
|
|
clkSrcChangeTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon any change in Clock Source."
|
|
::= { systemsEvents 10 }
|
|
|
|
agnUploadDataTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon an upload data session termination.
|
|
For more details see product specification."
|
|
::= { systemsEvents 11 }
|
|
|
|
enrollmentTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is a periodically trap, which sent to manager
|
|
untill Agent get any response (Get or Set) from this manager."
|
|
::= { systemsEvents 12 }
|
|
|
|
agnPowerFailureTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon power failure. It is applicable for
|
|
the following devices:
|
|
1. Devices having one PS unit, which sense the failure in advance,
|
|
and still have time to send this trap before it goes off.
|
|
2. Devices having 2 PS units and send this trap in order to notify a
|
|
failure in one of the units."
|
|
::= { systemsEvents 13 }
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\radds1.txt
|
|
--
|
|
-- RAD-DS1-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--Title: RAD-DS1 MIB
|
|
--
|
|
-- Copyright 1998 RAD Data Communications, Ltd.
|
|
-- All Rights Reserved.
|
|
|
|
-- IMPORTS
|
|
-- PerfCurrentCount, PerfIntervalCount FROM PerfHist-TC-MIB;
|
|
|
|
-- OBJECT-TYPE FROM RFC-1212
|
|
-- radWan FROM RAD-GEN-MIB;
|
|
-- RAD-DS1 MIB
|
|
|
|
--Title: RAD's DS1 INTERFACE MIB
|
|
--Date: 03.02.98
|
|
--By: Ilana Schvetz
|
|
--File: radds1.mib
|
|
|
|
-- Last updated by Shlomo Shoham 20-Jan-2003
|
|
|
|
ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4}
|
|
prtDs1PerfHistory OBJECT IDENTIFIER ::= {ds1Interface 1}
|
|
|
|
-- Extension to the dsx1 current table
|
|
|
|
dsx1XCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx1XCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of current statistics entries. This table
|
|
contains additional objects for the current table."
|
|
::= { prtDs1PerfHistory 2 }
|
|
|
|
dsx1XCurrentEntry OBJECT-TYPE
|
|
SYNTAX Dsx1XCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing additional statistical counters
|
|
applicable to a particular current table."
|
|
-- AUGMENTS { dsx1CurrentEntry }
|
|
INDEX { dsx1CurrentIndex }
|
|
::= { dsx1XCurrentTable 1 }
|
|
|
|
Dsx1XCurrentEntry ::=
|
|
SEQUENCE {
|
|
dsx1CurrentLOS PerfCurrentCount,
|
|
dsx1CurrentLOF PerfCurrentCount,
|
|
dsx1CurrentLOC PerfCurrentCount,
|
|
dsx1CurrentAIS PerfCurrentCount,
|
|
dsx1CurrentRAI PerfCurrentCount,
|
|
dsx1CurrentLOMF PerfCurrentCount,
|
|
dsx1CurrentFEBE PerfCurrentCount,
|
|
dsx1CurrentStatus OCTET STRING,
|
|
dsx1CurrentBPV PerfCurrentCount,
|
|
dsx1CurrentLOCRCMF PerfCurrentCount,
|
|
dsx1CurrentLOFC PerfCurrentCount,
|
|
dsx1CurrentCRCErrors PerfCurrentCount
|
|
|
|
|
|
}
|
|
|
|
dsx1CurrentLOS OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOS
|
|
seconds, encountered by a DS1 interface in
|
|
the current 15 minute interval."
|
|
::= { dsx1XCurrentEntry 1 }
|
|
|
|
dsx1CurrentLOF OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOF
|
|
seconds, encountered by a DS1
|
|
interface in the current 15 minute interval."
|
|
::= { dsx1XCurrentEntry 2 }
|
|
|
|
|
|
dsx1CurrentLOC OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver
|
|
lost cells delineation ."
|
|
::= { dsx1XCurrentEntry 3 }
|
|
|
|
dsx1CurrentAIS OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of AIS
|
|
seconds, encountered by a DS1
|
|
interface in the current 15 minute interval."
|
|
::= { dsx1XCurrentEntry 4 }
|
|
|
|
dsx1CurrentRAI OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote Alarm Indication: Transmitted in the outgoing direction
|
|
(toward the PABX) over FDL bits when the DS1 device detected
|
|
an incoming Loss Of Frame. Received from the far end (PABX)
|
|
over FDL when it detects a Loss of frame."
|
|
::= { dsx1XCurrentEntry 5 }
|
|
|
|
dsx1CurrentLOMF OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loss of Multi-Frame sequence in E1 time slot 16."
|
|
::= { dsx1XCurrentEntry 6 }
|
|
|
|
dsx1CurrentFEBE OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Block Errors, as reported in the first bit
|
|
of frames 13 and 15, on multiframe E1 lines with CRC4,
|
|
in the current 15 minute interval."
|
|
::= { dsx1XCurrentEntry 7 }
|
|
|
|
|
|
dsx1CurrentStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - Valid.
|
|
1 - redundantLinkSwitch - the link has been switched
|
|
by a redundancy mechanism.
|
|
2 - discontinuity - module was partialy out.
|
|
4 - notValid - module is out."
|
|
::= { dsx1XCurrentEntry 8 }
|
|
|
|
dsx1CurrentBPV OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of BPVs (Bi-Polar Violations)
|
|
encountered by a DS1 interface in the current 15 minute interval."
|
|
::= { dsx1XCurrentEntry 9 }
|
|
|
|
dsx1CurrentLOCRCMF OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loss of CRC4 Multi-Frame sequence in E1.
|
|
encountered in the current 15 minute interval"
|
|
::= { dsx1XCurrentEntry 10 }
|
|
|
|
dsx1CurrentLOFC OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Counts the number of loss of frame events measured.
|
|
encountered in the current 15 minute interval"
|
|
::= { dsx1XCurrentEntry 11 }
|
|
|
|
dsx1CurrentCRCErrors OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Counts the number of CRC error events,
|
|
encountered in the current 15 minute interval."
|
|
::= { dsx1XCurrentEntry 12 }
|
|
|
|
|
|
|
|
-- Interval table
|
|
|
|
dsx1XIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx1XIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A list of Interval entries. This table
|
|
contains additional objects for the interval table."
|
|
::= { prtDs1PerfHistory 3 }
|
|
|
|
dsx1XIntervalEntry OBJECT-TYPE
|
|
SYNTAX Dsx1XIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing additional statistical counters
|
|
applicable to a particular interval table."
|
|
-- AUGMENTS { dsx1IntervalEntry }
|
|
INDEX { dsx1IntervalIndex, dsx1IntervalNumber }
|
|
::= { dsx1XIntervalTable 1 }
|
|
|
|
Dsx1XIntervalEntry ::=
|
|
SEQUENCE {
|
|
dsx1IntervalLOS PerfIntervalCount,
|
|
dsx1IntervalLOF PerfIntervalCount,
|
|
dsx1IntervalLOC PerfIntervalCount,
|
|
dsx1IntervalAIS PerfIntervalCount,
|
|
dsx1IntervalRAI PerfIntervalCount,
|
|
dsx1IntervalLOMF PerfIntervalCount,
|
|
dsx1IntervalFEBE PerfIntervalCount,
|
|
dsx1IntervalStatus OCTET STRING,
|
|
dsx1IntervalBPV PerfIntervalCount,
|
|
dsx1IntervalLOCRCMF PerfIntervalCount,
|
|
dsx1IntervalLOFC PerfIntervalCount
|
|
}
|
|
|
|
|
|
dsx1IntervalLOS OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOS
|
|
seconds , encountered by a DS1 interface in
|
|
one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { dsx1XIntervalEntry 1 }
|
|
|
|
dsx1IntervalLOF OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of OOF
|
|
seconds, encountered by a DS1
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { dsx1XIntervalEntry 2 }
|
|
|
|
dsx1IntervalLOC OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver
|
|
lost cells delineation ."
|
|
::= { dsx1XIntervalEntry 3 }
|
|
|
|
dsx1IntervalAIS OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of AIS
|
|
seconds, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { dsx1XIntervalEntry 4 }
|
|
|
|
dsx1IntervalRAI OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote Alarm Indication: Transmitted in the outgoing direction
|
|
(toward the PABX) over FDL bits when the DS1 device detected
|
|
an incoming Loss Of Frame. Received from the far end (PABX)
|
|
over FDL when it detects a Loss of frame."
|
|
::= { dsx1XIntervalEntry 5 }
|
|
|
|
dsx1IntervalLOMF OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loss of Multi-Frame sequence in E1 time slot 16."
|
|
::= { dsx1XIntervalEntry 6 }
|
|
|
|
dsx1IntervalFEBE OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Block Errors, as reported in the first bit
|
|
of frames 13 and 15, on multiframe E1 lines with CRC4,
|
|
in one of the previous 96, individual, 15 minute intervals."
|
|
::= { dsx1XIntervalEntry 7 }
|
|
|
|
dsx1IntervalStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - Valid.
|
|
1 - redundantLinkSwitch - the link has been switched
|
|
by a redundancy mechanism.
|
|
2 - discontinuity - module was partialy out.
|
|
4 - notValid - module is out."
|
|
::= { dsx1XIntervalEntry 8 }
|
|
|
|
dsx1IntervalBPV OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of BPV (Bi-Polar Violations)
|
|
encountered by a DS1 interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { dsx1XIntervalEntry 9 }
|
|
|
|
dsx1IntervalLOCRCMF OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loss of CRC4 Multi-Frame sequence in E1."
|
|
::= { dsx1XIntervalEntry 10 }
|
|
|
|
dsx1IntervalLOFC OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Counts the number of loss of frame events measured
|
|
in one of the previous 96, individual 15 minute, intervals."
|
|
::= { dsx1XIntervalEntry 11 }
|
|
|
|
|
|
-- Extension to the dsx1 Total table
|
|
|
|
dsx1XTotalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx1XTotalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Total statistics entries. This table
|
|
contains additional objects for the Total table."
|
|
::= { prtDs1PerfHistory 4 }
|
|
|
|
dsx1XTotalEntry OBJECT-TYPE
|
|
SYNTAX Dsx1XTotalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing additional statistical counters
|
|
applicable to a particular current table."
|
|
-- AUGMENTS { dsx1CurrentEntry }
|
|
INDEX { dsx1TotalIndex }
|
|
::= { dsx1XTotalTable 1 }
|
|
|
|
Dsx1XTotalEntry ::=
|
|
SEQUENCE {
|
|
dsx1TotalBPV PerfTotalCount,
|
|
dsx1TotalLOFC PerfTotalCount
|
|
}
|
|
|
|
dsx1TotalBPV OBJECT-TYPE
|
|
SYNTAX PerfTotalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of BPV (Bi-Polar Violations)
|
|
encountered by a DS1 interface in the previous 24 hour interval.
|
|
Invalid 15 minute intervals count as 0."
|
|
::= { dsx1XTotalEntry 9 }
|
|
|
|
|
|
dsx1TotalLOFC OBJECT-TYPE
|
|
SYNTAX PerfTotalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number loss of frames
|
|
encountered by a DS1 interface in the previous 24 hour interval.
|
|
Invalid 15 minute intervals count as 0."
|
|
::= { dsx1XTotalEntry 11 }
|
|
|
|
|
|
-- Extension to the DS1 Configuration Table
|
|
|
|
dsx1XConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Dsx1XConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An extension to the DS1 Configuration table."
|
|
::= { ds1Interface 2 }
|
|
|
|
dsx1XConfigEntry OBJECT-TYPE
|
|
SYNTAX Dsx1XConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing additional configuration
|
|
parameters."
|
|
-- AUGMENTS { dsx1ConfigTable }
|
|
INDEX { dsx1LineIndex }
|
|
::= { dsx1XConfigTable 1 }
|
|
|
|
Dsx1XConfigEntry ::=
|
|
SEQUENCE {
|
|
dsx1IdleCode Integer32,
|
|
dsx1LineMode INTEGER,
|
|
dsx1dBTxGain INTEGER,
|
|
dsx1RxSensitivity INTEGER,
|
|
dsx1RestoreTime INTEGER,
|
|
dsx1TcFirstSignal Integer32,
|
|
dsx1TcSignal Integer32,
|
|
dsx1TcPattern Integer32,
|
|
dsx1Scramble INTEGER,
|
|
dsx1LineAdaptiveTimingMode INTEGER,
|
|
dsx1TxClockSource INTEGER,
|
|
dsx1AisEnable INTEGER,
|
|
dsx1TsEchoCancel OCTET STRING,
|
|
dsx1EchoCancelerModule INTEGER,
|
|
dsx1PortFunction INTEGER,
|
|
dsx1PortMultiplier INTEGER,
|
|
dsx1LeasedLine INTEGER,
|
|
dsx1CsuLoop INTEGER
|
|
}
|
|
|
|
dsx1IdleCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Byte pattern of the data received/transmitted in the
|
|
E1T1 framer idle timeslots.
|
|
Valid range: (0 - FF HEX)."
|
|
::= { dsx1XConfigEntry 1 }
|
|
|
|
dsx1LineMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
csu(1),
|
|
dsu(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T1 device operation mode.
|
|
Valid for T1 only."
|
|
::= { dsx1XConfigEntry 2 }
|
|
|
|
dsx1dBTxGain OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
neg75dB (2),
|
|
neg15dB (3),
|
|
neg225dB (4),
|
|
zerodB (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmit line Gain for T1 CSU line mode."
|
|
::= { dsx1XConfigEntry 3 }
|
|
|
|
dsx1RxSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
neg10dB (2),
|
|
neg32dB (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determine the maximum attenuation of the
|
|
receive signal that can be compensated for
|
|
by the interface receive path. Not applicable for T1."
|
|
::= { dsx1XConfigEntry 4 }
|
|
|
|
dsx1RestoreTime OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
sec1(2),
|
|
sec10(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to change the sync. algorithms to reduce the time
|
|
required for the port to return to normal operation after
|
|
a RED alarm."
|
|
::= { dsx1XConfigEntry 5 }
|
|
|
|
dsx1TcFirstSignal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trunk conditioning signal - value to be sent as a signal
|
|
during the first 2.5 seconds after alarm detection.
|
|
Range is 0x0..0xF. 0xFF is a NULL value. Valid for T1 only."
|
|
::= { dsx1XConfigEntry 6 }
|
|
|
|
dsx1TcSignal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trunk conditioning signal value after alarm detection.
|
|
Range is 0x1..0xF for E1, and 0x0..0xF for T1."
|
|
::= { dsx1XConfigEntry 7 }
|
|
|
|
dsx1TcPattern OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trunk conditioning data pattern to be sent upon a DS0 fail.
|
|
Range is 0x0..0xFF."
|
|
::= { dsx1XConfigEntry 8 }
|
|
|
|
dsx1Scramble OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
notActive (2),
|
|
active (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scrambling is an operation that randomizes the bits
|
|
of the payload of the ATM cell by a polynom.
|
|
This operation helps with the error detection mechanism
|
|
of the HEC. Not applicable for E1.
|
|
active - will scramble/descramble the payload ATM cell
|
|
notActive - will not scramble/descramble. "
|
|
::= { dsx1XConfigEntry 9 }
|
|
|
|
dsx1LineAdaptiveTimingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables end to end clock synchronization.
|
|
Default value - off."
|
|
::= { dsx1XConfigEntry 10 }
|
|
|
|
dsx1TxClockSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
loopTiming(1),
|
|
localTiming(2),
|
|
throughTiming(3),
|
|
adaptive(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source of Transmit Clock.
|
|
'loopTiming' indicates that the recovered receive clock
|
|
is used as the transmit clock.
|
|
|
|
'localTiming' indicates that a local clock
|
|
source is used or when an external clock is
|
|
attached to the box containing the interface.
|
|
|
|
'throughTiming' indicates that recovered receive clock
|
|
from another interface is used as the transmit clock.
|
|
|
|
'adaptive' indicates that the clock is recovered according
|
|
to the received data flow rate. "
|
|
::= { dsx1XConfigEntry 11 }
|
|
|
|
dsx1AisEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
disable(2),
|
|
enable(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/ disable AIS transmit when Ethernet cable (for TDMoIP) is out (disconnected)."
|
|
::= { dsx1XConfigEntry 12 }
|
|
|
|
dsx1TsEchoCancel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines for each TS whether Echo-Cancellation is on.
|
|
Each bit represents one TS as follow:
|
|
First octet bit'0' = TS#1, bit'7' = TS#8, .. 2nd octet bit'0' = TS#9,..,
|
|
4th octet bit'7' = TS#32.
|
|
Octets and bits order is from left to right:
|
|
[31,30,..24] [23..16] [15..8] [7..0]
|
|
MSB LSB MSB LSB MSB LSB MSB LSB
|
|
|
|
For each bit values are:
|
|
0 - Echo-Cancellation off.
|
|
1 - Echo-Cancellation on."
|
|
::= { dsx1XConfigEntry 13 }
|
|
|
|
dsx1EchoCancelerModule OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notExist(2),
|
|
exist(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whether echo-cancellation module
|
|
exists for this line."
|
|
::= { dsx1XConfigEntry 14 }
|
|
|
|
dsx1PortFunction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
uni (2),
|
|
ces (3),
|
|
ima (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the ATM Mode over the
|
|
physical port.
|
|
uni - The port will function as an ATM UNI.
|
|
ces - The port will function as a CES.
|
|
ima - The port will function as an IMA-ATM."
|
|
::= { dsx1XConfigEntry 15 }
|
|
|
|
dsx1PortMultiplier OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
r56 (2),
|
|
r64 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the data rate of each TS
|
|
(Kbps units).
|
|
This parameter is applicable for T1 only."
|
|
::= { dsx1XConfigEntry 16 }
|
|
|
|
dsx1LeasedLine OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines whether Line mode is regular (non Leased Line mode)
|
|
or transparent (Leased Line mode)."
|
|
::= { dsx1XConfigEntry 17 }
|
|
|
|
dsx1CsuLoop OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
local (2),
|
|
transparent (3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines whether CSU loop will be done locally (by IPmux)
|
|
or will be transferred to the TDM device."
|
|
::= { dsx1XConfigEntry 18 }
|
|
|
|
|
|
|
|
-- END
|
|
--
|
|
-- file :v:\doc\rdv\mib\Before~1\radds3.txt
|
|
--
|
|
-- RAD-DS3-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--Title: RAD-DS3 MIB
|
|
--
|
|
-- Copyright 1993 RAD Data Communications, Ltd.
|
|
-- All Rights Reserved.
|
|
|
|
-- It is RAD's intent to encourage the widespread use of
|
|
-- this Specification in connection with the management of
|
|
-- RAD products. RAD grants vendors, end-users,
|
|
-- and other interested parties a non-exclusive license to
|
|
-- use this Specification in connection with the management
|
|
-- of RAD products.
|
|
-- This Specification is supplied "as is," and RAD makes
|
|
-- no warranty, either express or implied, as to the use,
|
|
-- operation, condition, or performance of the Specification.
|
|
|
|
-- IMPORTS
|
|
-- Gauge32 FROM SNMPv2-SMI
|
|
-- ifIndex FROM SNMPv2-TC
|
|
-- OBJECT-TYPE FROM SNMPv2-SMI
|
|
-- radWan FROM RAD-GEN-MIB;
|
|
|
|
|
|
|
|
-- RAD-DS3 MIB
|
|
|
|
--Title: RAD's DS3 INTERFACE MIB
|
|
--Version: 1.0
|
|
--Date: 13.10.96
|
|
--By: Yair Arian
|
|
--File: ds3.mib
|
|
--
|
|
--Last update: 27.01.98 by Ilana
|
|
|
|
|
|
|
|
ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3}
|
|
|
|
prtDs3PerfHistory OBJECT IDENTIFIER ::= {ds3Interface 1}
|
|
|
|
|
|
-- The DS3 Interface Table
|
|
|
|
prtSDs3IfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtDs3IfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DS3 interface table."
|
|
::= { prtDs3PerfHistory 1 }
|
|
|
|
prtDs3IfEntry OBJECT-TYPE
|
|
SYNTAX PrtDs3IfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DS3 interface table."
|
|
INDEX { ifIndex }
|
|
::= { prtSDs3IfTable 1 }
|
|
|
|
PrtDs3IfEntry ::=
|
|
SEQUENCE {
|
|
prtDs3IfTimeElapsed
|
|
Integer32,
|
|
prtDs3IfValidIntervals
|
|
Integer32
|
|
}
|
|
|
|
prtDs3IfTimeElapsed OBJECT-TYPE
|
|
SYNTAX Integer32 (0..899)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds that have elapsed since
|
|
the beginning of the near end current error-
|
|
measurement period."
|
|
::= { prtDs3IfEntry 1 }
|
|
|
|
prtDs3IfValidIntervals OBJECT-TYPE
|
|
SYNTAX Integer32 (0..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of previous near end intervals for
|
|
which valid data was collected. The value will be
|
|
96 unless the interface was brought online within
|
|
the last 24 hours, in which case the value will be
|
|
the number of complete 15 minute near end
|
|
intervals since the interface has been online."
|
|
::= { prtDs3IfEntry 2 }
|
|
|
|
|
|
-- The DS3 Current Table
|
|
|
|
-- The DS3 Current table contains various statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
prtDs3CurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtDs3CurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DS3 Current table."
|
|
::= { prtDs3PerfHistory 2 }
|
|
|
|
prtDs3CurrentEntry OBJECT-TYPE
|
|
SYNTAX PrtDs3CurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DS3 Current table."
|
|
INDEX { ifIndex }
|
|
::= { prtDs3CurrentTable 1 }
|
|
|
|
PrtDs3CurrentEntry ::=
|
|
SEQUENCE {
|
|
prtDs3CurrentLOS
|
|
Gauge32,
|
|
prtDs3CurrentOOF
|
|
Gauge32,
|
|
prtDs3CurrentLOC
|
|
Gauge32,
|
|
prtDs3CurrentAIS
|
|
Gauge32,
|
|
prtDs3CurrentRDI
|
|
Gauge32,
|
|
prtDs3CurrentUAS
|
|
Gauge32,
|
|
prtDs3CurrentBIP
|
|
Gauge32,
|
|
prtDs3CurrentFEBE
|
|
Gauge32,
|
|
prtDs3CurrentSLM
|
|
Gauge32,
|
|
prtDs3CurrentSES
|
|
Gauge32,
|
|
prtDs3CurrentES
|
|
Gauge32,
|
|
prtDs3CurrentBitParity
|
|
Gauge32,
|
|
prtDs3CurrentPlcpLOF
|
|
Gauge32,
|
|
prtDs3CurrentPlcpRAI
|
|
Gauge32,
|
|
prtDs3CurrentPlcpBIP
|
|
Gauge32,
|
|
prtDs3CurrentPlcpFEBE
|
|
Gauge32,
|
|
prtDs3CurrentBPV
|
|
Gauge32,
|
|
prtDs3CurrentLCE
|
|
Gauge32,
|
|
prtDs3CurrentStatus
|
|
OCTET STRING
|
|
}
|
|
|
|
prtDs3CurrentLOS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOS
|
|
seconds, encountered by a DS3 interface in
|
|
the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 1 }
|
|
|
|
prtDs3CurrentOOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of OOF
|
|
seconds, encountered by a DS3
|
|
interface in the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 2 }
|
|
|
|
prtDs3CurrentLOC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOC
|
|
seconds, encountered by a DS3
|
|
interface in the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 3 }
|
|
|
|
prtDs3CurrentAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of AIS
|
|
seconds, encountered by a DS3
|
|
interface in the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 4 }
|
|
|
|
prtDs3CurrentRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of RDI
|
|
seconds, encountered by a DS3
|
|
interface."
|
|
::= { prtDs3CurrentEntry 5 }
|
|
|
|
prtDs3CurrentUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of UAS,
|
|
encountered by a SONET interface."
|
|
::= { prtDs3CurrentEntry 6 }
|
|
|
|
prtDs3CurrentBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
BIP errors, encountered by a DS3
|
|
interface in the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 7 }
|
|
|
|
prtDs3CurrentFEBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
FEBE errors, encountered by a DS3
|
|
interface in the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 8 }
|
|
|
|
prtDs3CurrentSLM OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SLM
|
|
seconds, encountered by an E3 (only )
|
|
interface in the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 9 }
|
|
|
|
prtDs3CurrentSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SES
|
|
encountered by a E3
|
|
interface in the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 10 }
|
|
|
|
prtDs3CurrentES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The number of Errored Seconds, encountered by a
|
|
DS3 interface in the current 15 minute interval."
|
|
::= { prtDs3CurrentEntry 11 }
|
|
|
|
prtDs3CurrentBitParity OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bit Parity Error counter. Relevant to T3 only."
|
|
::= { prtDs3CurrentEntry 12 }
|
|
|
|
prtDs3CurrentPlcpLOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOF
|
|
seconds, encountered by a DS3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals. This counter is relevant for plcpInternal(5)
|
|
or plcpExternal(6) configuration If frame types only."
|
|
::= { prtDs3CurrentEntry 13 }
|
|
|
|
prtDs3CurrentPlcpRAI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receiving Yellow/Remote Alarm Indication. This counter is
|
|
relevant for PLCP (external/internal) frame types only."
|
|
::= { prtDs3CurrentEntry 14 }
|
|
|
|
prtDs3CurrentPlcpBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The counter associated with the number of BIP errors,
|
|
encountered by a DS3 interface in the current 15 minute
|
|
interval. This counter is relevant for PLCP (external/internal)
|
|
frame types only."
|
|
::= { prtDs3CurrentEntry 15 }
|
|
|
|
prtDs3CurrentPlcpFEBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The counter associated with the number of FEBE
|
|
errors, encountered by a DS3 interface in the current
|
|
15 minute interval. This counter is relevant for PLCP
|
|
(external/internal) frame types only."
|
|
::= { prtDs3CurrentEntry 16 }
|
|
|
|
prtDs3CurrentBPV OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of BPVs (Bi-Polar Violations) , encountered by a
|
|
DS3 interface in the current 15 minute interval.
|
|
This object is relevant only for Electrical Line
|
|
of Fomi-E3/T3."
|
|
::= { prtDs3CurrentEntry 17 }
|
|
|
|
prtDs3CurrentLCE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of LCE (Link Code Errors) encountered
|
|
by a DS3 interface in the current 15 minute interval.
|
|
This object is relevant only for Optical Links
|
|
of Fomi-E3/T3."
|
|
::= { prtDs3CurrentEntry 18 }
|
|
|
|
prtDs3CurrentStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - Valid.
|
|
1 - redundantLinkSwitch - the link has been switched
|
|
by a redundancy mechanism.
|
|
2 - discontinuity - module was partialy out.
|
|
4 - notValid - module is out."
|
|
::= { prtDs3CurrentEntry 19 }
|
|
|
|
-- The DS3 interface Interval
|
|
|
|
-- The DS3 Interval Table contains various statistics
|
|
-- collected by the Interface over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
prtDs3IntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtDs3IntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DS3 Interval table."
|
|
::= { prtDs3PerfHistory 3 }
|
|
|
|
prtDs3IntervalEntry OBJECT-TYPE
|
|
SYNTAX PrtDs3IntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the DS3 Interval table."
|
|
INDEX { ifIndex, prtDs3IntervalNumber }
|
|
::= { prtDs3IntervalTable 1 }
|
|
|
|
PrtDs3IntervalEntry ::=
|
|
SEQUENCE {
|
|
prtDs3IntervalNumber
|
|
Integer32,
|
|
prtDs3IntervalLOS
|
|
Gauge32,
|
|
prtDs3IntervalOOF
|
|
Gauge32,
|
|
prtDs3IntervalLOC
|
|
Gauge32,
|
|
prtDs3IntervalAIS
|
|
Gauge32,
|
|
prtDs3IntervalRDI
|
|
Gauge32,
|
|
prtDs3IntervalUAS
|
|
Gauge32,
|
|
prtDs3IntervalBIP
|
|
Gauge32,
|
|
prtDs3IntervalFEBE
|
|
Gauge32,
|
|
prtDs3IntervalSLM
|
|
Gauge32,
|
|
prtDs3IntervalSES
|
|
Gauge32,
|
|
prtDs3IntervalES
|
|
Gauge32,
|
|
prtDs3IntervalBitParity
|
|
Gauge32,
|
|
prtDs3IntervalPlcpLOF
|
|
Gauge32,
|
|
prtDs3IntervalPlcpRAI
|
|
Gauge32,
|
|
prtDs3IntervalPlcpBIP
|
|
Gauge32,
|
|
prtDs3IntervalPlcpFEBE
|
|
Gauge32,
|
|
prtDs3IntervalBPV
|
|
Gauge32,
|
|
prtDs3IntervalLCE
|
|
Gauge32,
|
|
prtDs3IntervalStatus
|
|
OCTET STRING
|
|
}
|
|
|
|
prtDs3IntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { prtDs3IntervalEntry 1 }
|
|
|
|
prtDs3IntervalLOS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOS
|
|
seconds , encountered by a DS3 interface in
|
|
one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { prtDs3IntervalEntry 2 }
|
|
|
|
prtDs3IntervalOOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of OOF
|
|
seconds, encountered by a DS3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 3 }
|
|
|
|
prtDs3IntervalLOC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOC
|
|
seconds, encountered by a DS3
|
|
interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { prtDs3IntervalEntry 4 }
|
|
|
|
prtDs3IntervalAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of AIS
|
|
seconds, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 5 }
|
|
|
|
prtDs3IntervalRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of RDI
|
|
seconds, encountered by a DS3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 6 }
|
|
|
|
prtDs3IntervalUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of UAS,
|
|
encountered by a DS3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 7 }
|
|
|
|
prtDs3IntervalBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
BIP errors, encountered by a DS3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 8 }
|
|
|
|
prtDs3IntervalFEBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
FEBE errors, encountered by a DS3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 9 }
|
|
|
|
prtDs3IntervalSLM OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SLM
|
|
seconds, encountered by an E3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 10 }
|
|
|
|
prtDs3IntervalSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SES
|
|
encountered by a E3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 11 }
|
|
|
|
prtDs3IntervalES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The number of Errored Seconds, encountered by a
|
|
DS3 interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtDs3IntervalEntry 12 }
|
|
|
|
prtDs3IntervalBitParity OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bit Parity Error counter. Relevant to T3 only."
|
|
::= { prtDs3IntervalEntry 13 }
|
|
|
|
prtDs3IntervalPlcpLOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOF
|
|
seconds, encountered by a DS3
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals. This counter is relevant for plcpInternal(5)
|
|
or plcpExternal(6) configuration If frame types only."
|
|
::= { prtDs3IntervalEntry 14 }
|
|
|
|
prtDs3IntervalPlcpRAI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receiving Yellow/Remote Alarm Indication. This counter is
|
|
relevant for PLCP (external/internal) frame types only."
|
|
::= { prtDs3IntervalEntry 15 }
|
|
|
|
prtDs3IntervalPlcpBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The counter associated with the number of BIP errors,
|
|
encountered by a DS3 interface in the current 15 minute
|
|
interval. This counter is relevant for PLCP (external/internal)
|
|
frame types only."
|
|
::= { prtDs3IntervalEntry 16 }
|
|
|
|
prtDs3IntervalPlcpFEBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The counter associated with the number of FEBE
|
|
errors, encountered by a DS3 interface in the current
|
|
15 minute interval. This counter is relevant for PLCP
|
|
(external/internal) frame types only."
|
|
::= { prtDs3IntervalEntry 17 }
|
|
|
|
prtDs3IntervalBPV OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of BPVs (Bi-Polar Violations) , encountered by a
|
|
DS3 interface in the specified 15 minute interval.
|
|
This object is relevant only for Electrical Line
|
|
of Fomi-E3/T3."
|
|
::= { prtDs3IntervalEntry 18 }
|
|
|
|
prtDs3IntervalLCE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of LCE (Link Code Errors) encountered
|
|
by a DS3 interface in the specified 15 minute interval.
|
|
This object is relevant only for Optical Links
|
|
of Fomi-E3/T3."
|
|
::= { prtDs3IntervalEntry 19 }
|
|
|
|
|
|
prtDs3IntervalStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - Valid.
|
|
1 - redundantLinkSwitch - the link has been switched
|
|
by a redundancy mechanism.
|
|
2 - discontinuity - module was partialy out.
|
|
4 - notValid - module is out."
|
|
::= { prtDs3IntervalEntry 20 }
|
|
|
|
-- the DS3 Total table
|
|
|
|
prtDs3TotalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtDs3TotalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A list of Total entries."
|
|
::= { prtDs3PerfHistory 4 }
|
|
|
|
prtDs3TotalEntry OBJECT-TYPE
|
|
SYNTAX PrtDs3TotalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of Total table."
|
|
INDEX { ifIndex }
|
|
::= { prtDs3TotalTable 1 }
|
|
|
|
PrtDs3TotalEntry ::=
|
|
SEQUENCE {
|
|
prtDs3TotalUAS Gauge32,
|
|
prtDs3TotalBPV Gauge32,
|
|
prtDs3TotalLCE Gauge32
|
|
}
|
|
|
|
prtDs3TotalUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of UASs (Unavailable Seconds) , encountered by a
|
|
DS3 interface in the previous 96 intervals.
|
|
Invalid 15 minute intervals count as 0."
|
|
::= { prtDs3TotalEntry 6 }
|
|
|
|
prtDs3TotalBPV OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of BPVs (Bi-Polar Violations) , encountered by a
|
|
DS3 interface in the previous 96 intervals.
|
|
Invalid 15 minute intervals count as 0."
|
|
::= { prtDs3TotalEntry 17 }
|
|
|
|
prtDs3TotalLCE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of LCE (Link Code Errors) encountered
|
|
by a DS3 interface in the previous 96 intervals.
|
|
Invalid 15 minute intervals count as 0."
|
|
::= { prtDs3TotalEntry 18 }
|
|
-- END
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\brggen.txt
|
|
--
|
|
--Version 4.95
|
|
--Initial Version: 4.0
|
|
--Date: 16.10.94
|
|
--By: Debby Koren & Orly Nicklass
|
|
--File: BRGgen.txt
|
|
|
|
--Last Updated by Ilana Schvetz 15-Jan-2003.
|
|
|
|
|
|
genBridge OBJECT IDENTIFIER ::= {radBridges 1 }
|
|
|
|
-- At the end of the MIB there is a definition of all RAD general traps for bridges.
|
|
|
|
|
|
radBridgeAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reset(1),
|
|
sendNetworkTab(2),
|
|
deleteNetworkTab(3),
|
|
sendRoutingTab(4), -- Level II
|
|
deleteRoutinTab(5),
|
|
sendLanTab(6),
|
|
deleteLanTab(7),
|
|
deleteArpTab(8),
|
|
sendArpTab(9),
|
|
deleteRouteTab(10), -- Level III
|
|
sendRouteTab(11),
|
|
deactivateAllMasks(12),
|
|
saveAllActiveMasks(13),
|
|
loadAndActivateAllMasksFromNVRAM(14),
|
|
clearAllMasksFromNVRAM(15),
|
|
defaultConfig(16),
|
|
resetNVRAM(17),
|
|
clearIPNVRAM(18),
|
|
noOp(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable enables the operator to perform one of the
|
|
specified actions on the tables maintained by the network device.
|
|
Send actions are not currently implemented. Not all actions can
|
|
be performed on all bridges."
|
|
::= { genBridge 1 }
|
|
|
|
radBridgeInactiveArpTimeOut OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable defines the maximum time period that can pass
|
|
between ARP requests concerning an entry in the ARP table.
|
|
After this time period, the entry is deleted from the table."
|
|
::= { genBridge 2 }
|
|
|
|
|
|
-- radBridgeMaskTab defines the format of RAD Bridge OLD masking tables
|
|
|
|
radBridgeMaskTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeMaskEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mask tables enable definition of forwarding restrictions and
|
|
control of message flow in the internetwork. Each entry
|
|
in this table defines a mask statement consisting of up to
|
|
three mask definitions and an action defined by
|
|
radBridgeMaskOper. Different types of mask entries are supported,
|
|
as defined by radBridgeMaskType."
|
|
::= { genBridge 3 }
|
|
|
|
radBridgeMaskEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeMaskEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in table radBridgeMaskTable."
|
|
INDEX { radBridgeMaskType, radBridgeMaskIfIndex, radBridgeMaskNum }
|
|
::= { radBridgeMaskTable 1 }
|
|
|
|
RadBridgeMaskEntry ::= SEQUENCE {
|
|
radBridgeMaskType
|
|
INTEGER,
|
|
radBridgeMaskIfIndex
|
|
Integer32,
|
|
radBridgeMaskNum
|
|
Integer32,
|
|
radBridgeMaskDest
|
|
INTEGER,
|
|
radBridgeMaskPat1
|
|
OCTET STRING,
|
|
radBridgeMaskActiveBit1
|
|
OCTET STRING,
|
|
radBridgeMaskFrom1
|
|
INTEGER,
|
|
radBridgeMaskOffset1
|
|
Integer32,
|
|
radBridgeMaskCond1
|
|
INTEGER,
|
|
radBridgeMaskPat2
|
|
OCTET STRING,
|
|
radBridgeMaskActiveBit2
|
|
OCTET STRING,
|
|
radBridgeMaskFrom2
|
|
INTEGER,
|
|
radBridgeMaskOffset2
|
|
Integer32,
|
|
radBridgeMaskCond2
|
|
INTEGER,
|
|
radBridgeMaskPat3
|
|
OCTET STRING,
|
|
radBridgeMaskActiveBit3
|
|
OCTET STRING,
|
|
radBridgeMaskFrom3
|
|
INTEGER,
|
|
radBridgeMaskOffset3
|
|
Integer32,
|
|
radBridgeMaskCond3
|
|
INTEGER,
|
|
radBridgeMaskOper
|
|
INTEGER
|
|
}
|
|
|
|
radBridgeMaskType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tx(1),
|
|
rx(2),
|
|
compress(3),
|
|
priority(4),
|
|
loadSharing(5),
|
|
facs(6),
|
|
codConnect(7),
|
|
codDisconnect(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the type of mask entry."
|
|
::= { radBridgeMaskEntry 1 }
|
|
|
|
radBridgeMaskIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the if Index of the interface to which the mask is applied."
|
|
::= { radBridgeMaskEntry 2 }
|
|
|
|
radBridgeMaskNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Mask entry number, defined by its line number in the mask
|
|
table."
|
|
::= { radBridgeMaskEntry 3 }
|
|
|
|
radBridgeMaskDest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unassigned-cond (1),
|
|
broadcast-msge (2),
|
|
multicast-msge (3),
|
|
all-msge(4),
|
|
none(5)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the type of destination address carried by the frame
|
|
to which the mask will be applied. Unassigned-condition
|
|
deactivates the mask entry."
|
|
::= { radBridgeMaskEntry 4 }
|
|
|
|
|
|
radBridgeMaskPat1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING -- (SIZE (2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the mask field which is either a 16 bit binary pattern,
|
|
or four digit hexadecimal pattern."
|
|
::= { radBridgeMaskEntry 5 }
|
|
|
|
radBridgeMaskActiveBit1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING -- (SIZE (2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the positions of the wild card characters (*)
|
|
in the radBridgeMaskPat1 field."
|
|
::= { radBridgeMaskEntry 6 }
|
|
|
|
radBridgeMaskFrom1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mac(1),
|
|
llc(2),
|
|
net(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Offset base of radBridgeMaskPat1 within the frame.
|
|
Net can be in some cases the data start point."
|
|
::= { radBridgeMaskEntry 7 }
|
|
|
|
radBridgeMaskOffset1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the radBridgeMaskPat1 offset within the frame (in bytes) from
|
|
the base defined in by radBridgeMaskForm1.The mask offset is an even
|
|
decimal number in the range of 0 to 1518."
|
|
::= { radBridgeMaskEntry 8 }
|
|
|
|
radBridgeMaskCond1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
radBridgeMaskOffset1 the packet contains data that matches
|
|
the content of radBridgeMaskPat1.
|
|
|
|
false - Condition is valid if at the position specified by
|
|
radBridgeMaskOffset1 the packet contains data that does not
|
|
match the content of radBridgeMaskPat1."
|
|
::= { radBridgeMaskEntry 9 }
|
|
|
|
radBridgeMaskPat2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING -- (SIZE (2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the mask field which is either a 16 bit binary pattern,
|
|
or four digit hexadecimal pattern."
|
|
::= { radBridgeMaskEntry 10 }
|
|
|
|
radBridgeMaskActiveBit2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING -- (SIZE (2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the positions of the wild card characters (*)
|
|
in the radBridgeMaskPat2 field."
|
|
::= { radBridgeMaskEntry 11 }
|
|
|
|
radBridgeMaskFrom2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mac (1),
|
|
llc (2),
|
|
net(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Offset base of radBridgeMaskPat2 within the frame.
|
|
Net can be in some cases the data start point."
|
|
::= { radBridgeMaskEntry 12 }
|
|
|
|
radBridgeMaskOffset2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the radBridgeMaskPat2 offset within the frame (in bytes) from
|
|
the base defined in by radBridgeMaskForm2.The mask offset is an even
|
|
decimal number in the range of 0 to 1518."
|
|
::= { radBridgeMaskEntry 13 }
|
|
|
|
radBridgeMaskCond2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
radBridgeMaskOffset2 the packet contains data that matches
|
|
the content of radBridgeMaskPat2.
|
|
|
|
false - Condition is valid if at the position specified by
|
|
radBridgeMaskOffset2 the packet contains data that does not
|
|
match the content of radBridgeMaskPat2."
|
|
::= { radBridgeMaskEntry 14 }
|
|
|
|
radBridgeMaskPat3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING -- (SIZE (2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the mask field which is either a 16 bit binary pattern,
|
|
or four digit hexadecimal pattern."
|
|
::= { radBridgeMaskEntry 15 }
|
|
|
|
radBridgeMaskActiveBit3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING -- (SIZE (2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the positions of the wild card characters (*)
|
|
in the radBridgeMaskPat3 field."
|
|
::= { radBridgeMaskEntry 16 }
|
|
|
|
radBridgeMaskFrom3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mac (1),
|
|
llc (2),
|
|
net (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Offset base of radBridgeMaskPat3 within the frame.
|
|
Net can be in some cases the data start point."
|
|
::= { radBridgeMaskEntry 17 }
|
|
|
|
radBridgeMaskOffset3 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the radBridgeMaskPat3 offset within the frame (in bytes) from
|
|
the base defined in by radBridgeMaskForm3. The mask offset is an even
|
|
decimal number in the range of 0 to 1518."
|
|
::= { radBridgeMaskEntry 18 }
|
|
|
|
radBridgeMaskCond3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
radBridgeMaskOffset3 the packet contains data that matches
|
|
the content of radBridgeMaskPat3
|
|
|
|
false - Condition is valid if at the position specified by
|
|
radBridgeMaskOffset3 the packet contains data that does not
|
|
match the content of radBridgeMaskPat3."
|
|
::= { radBridgeMaskEntry 19 }
|
|
|
|
radBridgeMaskOper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
block (1),
|
|
forward (2),
|
|
route (3),
|
|
forward-route (4),
|
|
high-priority (5),
|
|
noOp(6),
|
|
delete(7)
|
|
}
|
|
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of action to be taken if the frame meets the
|
|
conditions of the mask.
|
|
noOp = disabled (mask remains on list, but is not active)
|
|
delete = mask is removed from the list. "
|
|
::= { radBridgeMaskEntry 20 }
|
|
|
|
radBridgeCOD OBJECT IDENTIFIER ::= {genBridge 4 }
|
|
|
|
radBridgeCODParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeCODEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of COD parameters "
|
|
::= { radBridgeCOD 1}
|
|
|
|
|
|
radBridgeCODEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeCODEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each radBridgeCODEntry consists of the following parameters"
|
|
INDEX {radBridgeCODIfIndex}
|
|
::= { radBridgeCODParamTable 1 }
|
|
|
|
|
|
RadBridgeCODEntry ::= SEQUENCE {
|
|
radBridgeCODIfIndex
|
|
Integer32,
|
|
radBridgeCODManualConnect
|
|
INTEGER,
|
|
radBridgeCODMode
|
|
INTEGER,
|
|
radBridgeCODConnectDelay
|
|
Integer32,
|
|
radBridgeCODisConnectDelay
|
|
Integer32,
|
|
radBridgeCODImplicitSwitch
|
|
INTEGER,
|
|
radBridgeCODNumAccess
|
|
Counter32,
|
|
radBridgeCODTotalConnecTime
|
|
Integer32
|
|
}
|
|
|
|
radBridgeCODIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface to which this COD entry is applicable."
|
|
::= { radBridgeCODEntry 1 }
|
|
|
|
radBridgeCODManualConnect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
connect(1),
|
|
disconnect(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The management station can start connection manually
|
|
by setting this parameter"
|
|
::= { radBridgeCODEntry 2 }
|
|
|
|
|
|
radBridgeCODMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
answer(1),
|
|
originate(2),
|
|
disable(3),
|
|
answerAndOriginate(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In answer mode only one incoming call may be accepted at a time. Other nodes
|
|
attempting to access the local modem will receive a busy signal until the
|
|
connection is terminated. (Answer mode has no difficulty supporting multiple
|
|
remote connections to one local port, as blocking multiple incoming calls is
|
|
just a modem function. Originate mode, on the other
|
|
hand will only support a single local port to remote port connection).
|
|
The disable parameter disables the COD utility for this interface.
|
|
Choosing any other mode will enable the COD utility."
|
|
::= { radBridgeCODEntry 3 }
|
|
|
|
radBridgeCODConnectDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connect delay defines the minimum time period that
|
|
the link must stay disconnected, between 2 succesive
|
|
connections (in seconds)."
|
|
::= { radBridgeCODEntry 4 }
|
|
|
|
radBridgeCODisConnectDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disconnect delay defines the minimum time period
|
|
the link must stay connected, between 2 succesive
|
|
disconnections (in seconds)."
|
|
::= { radBridgeCODEntry 5 }
|
|
|
|
|
|
radBridgeCODImplicitSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inplicit switch allows the user to ignore implicit triggers provided
|
|
by the COD software."
|
|
-- DEFVAL { 1 }
|
|
::= { radBridgeCODEntry 6 }
|
|
|
|
|
|
radBridgeCODNumAccess OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of successful connections that have been established since
|
|
the COD has been reset."
|
|
::= { radBridgeCODEntry 7}
|
|
|
|
radBridgeCODTotalConnecTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sum of all the connect time intervals since the COD was reset."
|
|
::= { radBridgeCODEntry 8}
|
|
|
|
|
|
|
|
|
|
|
|
radBridgeCODTimeTriggerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeCODTimeTriggerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of COD parameters "
|
|
::= { radBridgeCOD 2 }
|
|
|
|
radBridgeCODTimeTriggerEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeCODTimeTriggerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each radBridgeCODTimeTriggerEntry consists of the following parameters"
|
|
INDEX { radBridgeCODTimeIfIndex, radBridgeCODDay, radBridgeCODTimeTriggerNum }
|
|
::= { radBridgeCODTimeTriggerTable 1 }
|
|
|
|
RadBridgeCODTimeTriggerEntry ::= SEQUENCE {
|
|
radBridgeCODTimeIfIndex
|
|
Integer32,
|
|
radBridgeCODDay
|
|
INTEGER,
|
|
radBridgeCODTimeTriggerNum
|
|
Integer32,
|
|
radBridgeCODTimeTriggerFrom
|
|
DisplayString,
|
|
radBridgeCODTimeTriggerTo
|
|
DisplayString,
|
|
radBridgeCODTimeTriggerStatus
|
|
INTEGER
|
|
}
|
|
|
|
radBridgeCODTimeIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface to which this COD Time Trigger entry is applicable."
|
|
::= { radBridgeCODTimeTriggerEntry 1}
|
|
|
|
radBridgeCODDay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mon(1),
|
|
tue(2),
|
|
wed(3),
|
|
thu(4),
|
|
fri(5),
|
|
sat(6),
|
|
sun(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The day of the week in which the dial up connection operates."
|
|
::= { radBridgeCODTimeTriggerEntry 2 }
|
|
|
|
radBridgeCODTimeTriggerNum OBJECT-TYPE
|
|
SYNTAX Integer32 (1..3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Every day of the week the user can configure 3 dial up connections."
|
|
::= { radBridgeCODTimeTriggerEntry 3 }
|
|
|
|
radBridgeCODTimeTriggerFrom OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time to start Dial Up connection, in format hh:mm."
|
|
::= {radBridgeCODTimeTriggerEntry 4 }
|
|
|
|
radBridgeCODTimeTriggerTo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time to terminate Dial Up connection, in format HH:MM."
|
|
::= {radBridgeCODTimeTriggerEntry 5 }
|
|
|
|
radBridgeCODTimeTriggerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
invalid(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a table entry."
|
|
::= { radBridgeCODTimeTriggerEntry 6 }
|
|
|
|
radBridgeCODTraffic OBJECT IDENTIFIER ::= { radBridgeCOD 3}
|
|
|
|
radBridgeCODTrafficTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeCODTrafficEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of COD Traffic trigger "
|
|
::= { radBridgeCODTraffic 1 }
|
|
|
|
radBridgeCODTrafficEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeCODTrafficEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each radBridgeCODTrafficEntry consists of the following parameters."
|
|
INDEX {radBridgeCODProtocolType}
|
|
::= { radBridgeCODTrafficTable 1}
|
|
|
|
|
|
RadBridgeCODTrafficEntry ::= SEQUENCE {
|
|
radBridgeCODProtocolType
|
|
INTEGER,
|
|
radBridgeCODTrafficTriggerStatus
|
|
INTEGER }
|
|
|
|
|
|
radBridgeCODProtocolType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ip(1),
|
|
ipx(2),
|
|
other(3)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Protocol Type of the Traffic Table"
|
|
::= { radBridgeCODTrafficEntry 1 }
|
|
|
|
|
|
radBridgeCODTrafficTriggerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Command of Status of the Protocol Traffic Trigger"
|
|
::= { radBridgeCODTrafficEntry 2 }
|
|
|
|
|
|
radBridgeCODRemoteIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This is the Remote IP Address"
|
|
::= { radBridgeCODTraffic 2 }
|
|
|
|
|
|
radBridgeCODIPMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This is the Mask of the Remote IP Address"
|
|
::= { radBridgeCODTraffic 3 }
|
|
|
|
radBridgeCODTrafficTriggerProtType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Protocol Type for the User Defined Protocol Traffic Trigger (3)."
|
|
::= { radBridgeCODTraffic 4 }
|
|
|
|
|
|
--COD Condition table
|
|
|
|
radBridgeCODCondTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeCODCondEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of COD Condition parameters "
|
|
::= { radBridgeCOD 4}
|
|
|
|
|
|
radBridgeCODCondEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeCODCondEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each radBridgeCODCondEntry consists of the following parameters"
|
|
INDEX {radBridgeCODCondIfIndex}
|
|
::= { radBridgeCODCondTable 1 }
|
|
|
|
|
|
RadBridgeCODCondEntry ::= SEQUENCE {
|
|
radBridgeCODCondIfIndex
|
|
Integer32,
|
|
radBridgeCODOriginateConnectCondition
|
|
INTEGER,
|
|
radBridgeCODOriginateDisConnectCondition
|
|
INTEGER,
|
|
radBridgeCODOriginateDisConnectDelay
|
|
Integer32,
|
|
radBridgeCODAnswerConnectCondition
|
|
INTEGER,
|
|
radBridgeCODSpecificOnTrafficOIDCondition
|
|
OBJECT IDENTIFIER,
|
|
radBridgeCODDisConnectMinimunFramesNumber
|
|
Integer32
|
|
|
|
|
|
|
|
}
|
|
|
|
|
|
radBridgeCODCondIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface, this COD entry is applicable to."
|
|
::= { radBridgeCODCondEntry 1 }
|
|
|
|
radBridgeCODOriginateConnectCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
onPowerOn (1),
|
|
whenAnyStationOnLan (2),
|
|
onTraffic (3),
|
|
onManualConnect (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This condition, allows the user to specify the
|
|
condition under which the link is connected.
|
|
The options are
|
|
onPowerOn - On power on.
|
|
whenAnyStationOnLan - When any station on lan.
|
|
onTraffic - On traffic. The user can specify the
|
|
condition/s for connection.
|
|
The connection will be defined in
|
|
CODSpecificOnTrafficConditionOID .
|
|
onManualConnect - depends on radBridgeCODManualConnect
|
|
OBJECT-TYPE (=connect).
|
|
"
|
|
::= { radBridgeCODCondEntry 2 }
|
|
|
|
radBridgeCODOriginateDisConnectCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStationOnLan (1),
|
|
onTraffic (2),
|
|
onDelayFromConnectionOnRequest (3),
|
|
onManualDisConnect (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This condition allows the user to specify the
|
|
condition under which the link is disconnected.
|
|
The options are:
|
|
noStationOnLan - When there is no station on lan.
|
|
Counts 15 minutes from the point the last
|
|
frame from lan has been received. If no
|
|
frame have been transmitted on lan by the
|
|
end of this period, disconnect the connection.
|
|
onTraffic - On traffic. The user can specify the
|
|
condition/s for disconnection.
|
|
The disconnection will be defined in
|
|
CODSpecificOnTrafficConditionOID .
|
|
onDelayFromConnectionOnRequest -
|
|
On Delay From Connection On Request .
|
|
The delay time period will be defined in
|
|
CODOriginateDisConnectDelay .
|
|
onManualDisConnect - depends on radBridgeCODManualConnect
|
|
OBJECT-TYPE (=disconnect).
|
|
"
|
|
::= { radBridgeCODCondEntry 3 }
|
|
|
|
radBridgeCODOriginateDisConnectDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delay time in seconds. "
|
|
::= { radBridgeCODCondEntry 4 }
|
|
|
|
radBridgeCODAnswerConnectCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
onPowerOn (1),
|
|
whenAnyStationOnLan (2),
|
|
onTraffic (3),
|
|
onManualConnect (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CODCondAnswerConnect allows the user to specify
|
|
the condition under which the link is connected.
|
|
The options are:
|
|
onPowerOn - On power on.
|
|
whenAnyStationOnLan - When any station on lan.
|
|
onTraffic - On traffic. The user can specify the
|
|
condition/s for connection.
|
|
The connection will be defined in
|
|
CODSpecificOnTrafficConditionOID .
|
|
onManualConnect - depends on radBridgeCODManualConnect
|
|
OBJECT-TYPE .
|
|
"
|
|
::= { radBridgeCODCondEntry 5 }
|
|
|
|
|
|
radBridgeCODSpecificOnTrafficOIDCondition OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to a specific entry in the
|
|
radBridgeMaskTable, which describes the
|
|
particular COD condition .
|
|
If Connect or Disconnect Conditions are not
|
|
onTraffic, its value should be set to the
|
|
OBJECT IDENTIFIER { 0 0 }. "
|
|
::= { radBridgeCODCondEntry 6 }
|
|
|
|
|
|
radBridgeCODDisConnectMinimunFramesNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frames rate."
|
|
::= { radBridgeCODCondEntry 7 }
|
|
|
|
--The IPX following objects define the Spoofing
|
|
|
|
radBridgeIPX OBJECT IDENTIFIER ::= {genBridge 5 }
|
|
|
|
|
|
radBridgeIPXdriver OBJECT IDENTIFIER ::= {radBridgeIPX 1 }
|
|
radBridgeIPXRip OBJECT IDENTIFIER ::= {radBridgeIPX 2 }
|
|
radBridgeIPXSap OBJECT IDENTIFIER ::= {radBridgeIPX 3 }
|
|
|
|
radBridgeIPXForwarding OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
forwarding(1),
|
|
not-forwarding(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of whether this entity is acting as an IPX
|
|
gateway in respect to the forwarding of datagrams received by,
|
|
but not addressed to, this entity. IPX gateways forward
|
|
datagrams. IPX hosts do not. Note that changing this parameter
|
|
requiers RESET of the router."
|
|
-- DEFVAL { 1 }
|
|
::= { radBridgeIPXdriver 1 }
|
|
|
|
radBridgeIPXRipOutPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of packets transmitted by RIP."
|
|
::= { radBridgeIPXRip 1 }
|
|
|
|
radBridgeIPXRipInPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of packets received by RIP. This will include
|
|
any packets that are subsequently discarded."
|
|
::= { radBridgeIPXRip 2 }
|
|
|
|
radBridgeIPXRipInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of received packets discarded by RIP."
|
|
::= { radBridgeIPXRip 3 }
|
|
|
|
radBridgeIPXRipTblNoOfEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The max number of entries that exist in the RIP routing table."
|
|
::= { radBridgeIPXRip 4 }
|
|
|
|
radBridgeIPXRipTblBcastTrigUpdateInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default time interval (in seconds)between triggered RIP updates on
|
|
a broadcast type interface. A triggered update occurs when a change is
|
|
detected in the routing database. This time interval delays the
|
|
broadcasting of these updates so that changes on the network will
|
|
not result in a lot of triggered updates."
|
|
::= { radBridgeIPXRip 5 }
|
|
|
|
|
|
|
|
radBridgeIPXRipTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeIPXRipTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The routing table used by RIP to calculate routes to remote
|
|
desination networks."
|
|
::= { radBridgeIPXRip 6 }
|
|
|
|
radBridgeIPXRipTableEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeIPXRipTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The routing information for one of this entity's destination networks."
|
|
INDEX { radBridgeIPXRipDestNetwork,
|
|
radBridgeIPXRipPolicy }
|
|
::= { radBridgeIPXRipTable 1 }
|
|
|
|
RadBridgeIPXRipTableEntry ::= SEQUENCE {
|
|
radBridgeIPXRipDestNetwork
|
|
OCTET STRING (SIZE(4)),
|
|
radBridgeIPXRipPolicy
|
|
INTEGER,
|
|
radBridgeIPXRipForwardingRouter
|
|
OCTET STRING (SIZE(6)),
|
|
radBridgeIPXRipNIC
|
|
Integer32,
|
|
radBridgeIPXRipTickMetric
|
|
Integer32,
|
|
radBridgeIPXRipHopMetric
|
|
Integer32,
|
|
radBridgeIPXRipAgingTime
|
|
TimeTicks,
|
|
radBridgeIPXRipValueStatus
|
|
INTEGER,
|
|
radBridgeIPXRipForwardType
|
|
INTEGER
|
|
}
|
|
|
|
radBridgeIPXRipDestNetwork OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination network address to which this entry's
|
|
routing information pertains."
|
|
::= {radBridgeIPXRipTableEntry 1 }
|
|
|
|
radBridgeIPXRipPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
main(1),
|
|
alternate(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value specifying the precidence of the route. A value of
|
|
zero means that the route is the best route, a value of one
|
|
means that the route is the second best route and so on."
|
|
::= { radBridgeIPXRipTableEntry 2 }
|
|
|
|
radBridgeIPXRipForwardingRouter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX node address of the next hop (router) for the
|
|
entry's associated destination network."
|
|
::= { radBridgeIPXRipTableEntry 3 }
|
|
|
|
radBridgeIPXRipNIC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An interface identifier specifying what IPX interface the
|
|
next hop can be found on."
|
|
::= { radBridgeIPXRipTableEntry 4 }
|
|
|
|
radBridgeIPXRipTickMetric OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The metric, in terms of transit time, associated with the route
|
|
given by the entry. This time is in terms of 1/18ths of a
|
|
second."
|
|
::= { radBridgeIPXRipTableEntry 5 }
|
|
|
|
radBridgeIPXRipHopMetric OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The metric, in terms of distance , associated with the route
|
|
given by the entry."
|
|
::= { radBridgeIPXRipTableEntry 6 }
|
|
|
|
|
|
radBridgeIPXRipAgingTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last time that the entry was updated. The time will be
|
|
provided in terms of the MIB-I object sysUpTime."
|
|
::= {radBridgeIPXRipTableEntry 7 }
|
|
|
|
radBridgeIPXRipValueStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dynamic(2),
|
|
invalid(3),
|
|
semiDynamic(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry status value; whether the entry is permanent (added
|
|
statically), reachable or unreachable. In the latter two cases
|
|
it would be added by RIP. A semiDynamic entry is an entry
|
|
enterd manualy by the user and can be updated by the router."
|
|
::= { radBridgeIPXRipTableEntry 8 }
|
|
|
|
radBridgeIPXRipForwardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1), -- not specified by this MIB
|
|
local (2), -- local interface
|
|
remote (3) -- remote destination
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of route. Note that local(2) refers to a route for which the
|
|
next hop is the final destination; remote(3) refers to a route
|
|
for which the next hop is not the final destination."
|
|
::= {radBridgeIPXRipTableEntry 9 }
|
|
|
|
|
|
|
|
radBridgeIPXRipInfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeIPXRipInfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RIP interface table."
|
|
::= { radBridgeIPXRip 7 }
|
|
|
|
radBridgeIPXRipInfEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeIPXRipInfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry corresponds to one ifindex."
|
|
INDEX { radBridgeIPXRipInfIfIndex}
|
|
::= { radBridgeIPXRipInfTable 1 }
|
|
|
|
RadBridgeIPXRipInfEntry ::= SEQUENCE {
|
|
radBridgeIPXRipInfIfIndex
|
|
Integer32,
|
|
radBridgeIPXRipInfBcastUpdate
|
|
Integer32,
|
|
radBridgeIPXRipInfAgeMultiplier
|
|
Integer32
|
|
}
|
|
|
|
radBridgeIPXRipInfIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value of Ifindex is same as radBridgeIPXIfIndex in the
|
|
IPX Interface Table."
|
|
::= { radBridgeIPXRipInfEntry 1 }
|
|
|
|
radBridgeIPXRipInfBcastUpdate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RIP periodic update interval, in seconds. Zero value
|
|
corresponds to infinite interval."
|
|
-- DEFVAL {60}
|
|
::= { radBridgeIPXRipInfEntry 2 }
|
|
|
|
radBridgeIPXRipInfAgeMultiplier OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The holding multiplier for information received in RIP
|
|
periodic updates. Zero value corresponds to infinite aging time."
|
|
-- DEFVAL {3}
|
|
::= { radBridgeIPXRipInfEntry 3 }
|
|
|
|
radBridgeIPXSapOutPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of packets transmitted by SAP."
|
|
::= { radBridgeIPXSap 1 }
|
|
|
|
radBridgeIPXSapInPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of packets received by SAP. This will include
|
|
any packets that are subsequently discarded."
|
|
::= { radBridgeIPXSap 2 }
|
|
|
|
radBridgeIPXSapInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of received packets discarded by SAP."
|
|
::= { radBridgeIPXSap 3 }
|
|
|
|
|
|
radBridgeIPXSapTblNoOfEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The max number of entries that exist in the SAP Server
|
|
Information table."
|
|
::= { radBridgeIPXSap 4 }
|
|
|
|
radBridgeIPXSapTblBcastTrigUpdateInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default time interval (in seconds) between triggered SAP updates on a
|
|
broadcast style interface. A triggered update occurs when a
|
|
change is detected in the service database. This time interval
|
|
delays the transmission of these updates so that changes on the
|
|
network will not result in a lot of triggered updates."
|
|
::= { radBridgeIPXSap 5 }
|
|
|
|
|
|
|
|
radBridgeIPXSapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeIPXSapTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Server Information table is used by SAP to store information
|
|
of services which are available on the internetwork."
|
|
::= { radBridgeIPXSap 6 }
|
|
|
|
radBridgeIPXSapTableEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeIPXSapTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The server information for one of this entity's server entries."
|
|
INDEX { radBridgeIPXSapServerType,
|
|
radBridgeIPXSapName }
|
|
::= { radBridgeIPXSapTable 1 }
|
|
|
|
RadBridgeIPXSapTableEntry ::= SEQUENCE {
|
|
radBridgeIPXSapServerType
|
|
Integer32,
|
|
radBridgeIPXSapName
|
|
DisplayString (SIZE(48)),
|
|
radBridgeIPXSapNetwork
|
|
OCTET STRING (SIZE(4)),
|
|
radBridgeIPXSapNode
|
|
OCTET STRING (SIZE(6)),
|
|
radBridgeIPXSapSocket
|
|
Integer32,
|
|
radBridgeIPXSapHopsToServer
|
|
Integer32,
|
|
radBridgeIPXSapNIC
|
|
Integer32,
|
|
radBridgeIPXSapAgingTime
|
|
TimeTicks,
|
|
radBridgeIPXSapStatus
|
|
INTEGER
|
|
}
|
|
|
|
radBridgeIPXSapServerType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the server for which this entry pertains."
|
|
::= { radBridgeIPXSapTableEntry 1 }
|
|
|
|
radBridgeIPXSapName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(48))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the server for which this entry pertains."
|
|
::= { radBridgeIPXSapTableEntry 2 }
|
|
|
|
radBridgeIPXSapNetwork OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX network address of the host on which this server exists."
|
|
::= { radBridgeIPXSapTableEntry 3 }
|
|
|
|
radBridgeIPXSapNode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX node address of the host on which this server exists."
|
|
::= { radBridgeIPXSapTableEntry 4 }
|
|
|
|
radBridgeIPXSapSocket OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPX socket number that is being used by the server to
|
|
which this entry pertains."
|
|
::= { radBridgeIPXSapTableEntry 5 }
|
|
|
|
radBridgeIPXSapHopsToServer OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of hops to the entity on which this server exists."
|
|
::= { radBridgeIPXSapTableEntry 6 }
|
|
|
|
radBridgeIPXSapNIC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Network Interface Card identifier specifying what IPX
|
|
interface the next hop can be found on."
|
|
::= { radBridgeIPXSapTableEntry 7 }
|
|
|
|
radBridgeIPXSapAgingTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last time that the entry was updated. The time will be
|
|
provided in terms of the MIB-I object sysUpTime."
|
|
::= { radBridgeIPXSapTableEntry 8 }
|
|
|
|
radBridgeIPXSapStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
permanent(1),
|
|
dynamic(2),
|
|
invalid(3),
|
|
semiDynamic(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the entry."
|
|
::= { radBridgeIPXSapTableEntry 9 }
|
|
|
|
|
|
|
|
radBridgeIPXSapInfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeIPXSapInfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Sap interface table."
|
|
::= { radBridgeIPXSap 7 }
|
|
|
|
radBridgeIPXSapInfEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeIPXSapInfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry corresponds to one ifindex."
|
|
INDEX {radBridgeIPXSapInfIfIndex}
|
|
::= { radBridgeIPXSapInfTable 1 }
|
|
|
|
RadBridgeIPXSapInfEntry ::= SEQUENCE {
|
|
radBridgeIPXSapInfIfIndex
|
|
Integer32,
|
|
radBridgeIPXSapInfBcastUpdate
|
|
Integer32,
|
|
radBridgeIPXSapInfAgeMultiplier
|
|
Integer32
|
|
}
|
|
|
|
radBridgeIPXSapInfIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value of Ifindex is same as radBridgeIPXIfIndex in the
|
|
IPX Interface Table."
|
|
::= { radBridgeIPXSapInfEntry 1 }
|
|
|
|
radBridgeIPXSapInfBcastUpdate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAP periodic update interval, in seconds. Zero value
|
|
corresponds to infinite interval."
|
|
-- DEFVAL {60}
|
|
::= { radBridgeIPXSapInfEntry 2 }
|
|
|
|
radBridgeIPXSapInfAgeMultiplier OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The holding multiplier for information received in SAP
|
|
periodic updates. Zero value corresponds to infinite aging time."
|
|
-- DEFVAL {3}
|
|
::= { radBridgeIPXSapInfEntry 3 }
|
|
|
|
|
|
-- radMaskingTab defines the new format of RAD Bridge masking tables
|
|
|
|
|
|
GenAddress ::= OCTET STRING (SIZE(12))
|
|
|
|
newMasking OBJECT IDENTIFIER ::= {genBridge 6 }
|
|
|
|
maskingMaxEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of entries in the masking table."
|
|
::= { newMasking 1 }
|
|
|
|
|
|
maskingCurrentEntries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of entries in the mask table."
|
|
::= { newMasking 2 }
|
|
|
|
maskingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MaskingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the new masking scheme.
|
|
Mask tables enable definition of forwarding restrictions and
|
|
control of message flow in the internetwork. Each entry
|
|
in this table defines a mask statement and an action defined by
|
|
maskingOperation."
|
|
::= { newMasking 3 }
|
|
|
|
maskingEntry OBJECT-TYPE
|
|
SYNTAX MaskingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the contents of each line in the mask table."
|
|
INDEX { maskingType, maskingIfIndex, maskingIndex }
|
|
::= { maskingTable 1 }
|
|
|
|
MaskingEntry ::= SEQUENCE {
|
|
maskingType
|
|
INTEGER,
|
|
maskingIfIndex
|
|
Integer32,
|
|
maskingIndex
|
|
Integer32,
|
|
maskingProtocolType
|
|
INTEGER,
|
|
maskingSmartMaskOID
|
|
OBJECT IDENTIFIER,
|
|
maskingFrameType
|
|
INTEGER,
|
|
maskingFrameTypeCondition
|
|
INTEGER,
|
|
maskingSourceAddress
|
|
GenAddress,
|
|
maskingSourceActiveBits
|
|
GenAddress,
|
|
maskingSourceMacOrNet
|
|
INTEGER,
|
|
maskingSourceCondition
|
|
INTEGER,
|
|
maskingDestAddress
|
|
GenAddress,
|
|
maskingDestActiveBits
|
|
GenAddress,
|
|
maskingDestMacOrNet
|
|
INTEGER,
|
|
maskingDestCondition
|
|
INTEGER,
|
|
maskingLowLevelProt
|
|
INTEGER,
|
|
maskingLowLevelProtCondition
|
|
INTEGER,
|
|
maskingHighLevelProt
|
|
Integer32,
|
|
maskingHighLevelProtCondition
|
|
INTEGER,
|
|
maskingPortNum
|
|
Integer32,
|
|
maskingPortNumCondition
|
|
INTEGER,
|
|
maskingOperation
|
|
INTEGER,
|
|
maskingSrcPortNum
|
|
Integer32,
|
|
maskingSrcPortNumCondition
|
|
INTEGER
|
|
}
|
|
|
|
maskingType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tx (1),
|
|
rx (2),
|
|
compress(3),
|
|
priority(4),
|
|
loadSharing(5),
|
|
facs(6),
|
|
codConnect(7),
|
|
codDisconnect(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the type of mask entry. "
|
|
::= { maskingEntry 1 }
|
|
|
|
|
|
maskingIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the ifIndex of the interface to which the mask is applied."
|
|
::= { maskingEntry 2 }
|
|
|
|
|
|
|
|
maskingIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index to the masking table. This number should not be greater than maskingMaxEntries"
|
|
::= { maskingEntry 3 }
|
|
|
|
|
|
|
|
|
|
maskingProtocolType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
ip (2),
|
|
ipx (3),
|
|
sna (4),
|
|
netbios (5),
|
|
apple (6),
|
|
dec (7),
|
|
all (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base protocol for masking. IPX, IP, others."
|
|
::= { maskingEntry 4 }
|
|
|
|
|
|
maskingSmartMaskOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to a specific Smart mask table (old radBridgeMaskTable)
|
|
which enables a more specific mask type.
|
|
If this information is not available, its value
|
|
should be set to the OBJECT IDENTIFIER { 0 0 }. "
|
|
::= { maskingEntry 5 }
|
|
|
|
|
|
maskingFrameType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
all (2),
|
|
broadcast (3),
|
|
multicast (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables the user to decide about frame type
|
|
* all frame
|
|
* just broadcast
|
|
* just multicast."
|
|
::= { maskingEntry 6 }
|
|
|
|
maskingFrameTypeCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
maskingFrameType the packet contains data that matches
|
|
the content of maskingFrameType.
|
|
|
|
fa lse - Condition is valid if at the position specified by
|
|
maskingFrameType the packet contains data that does not
|
|
match the content of maskingFrameType."
|
|
::= { maskingEntry 7 }
|
|
|
|
maskingSourceAddress OBJECT-TYPE
|
|
SYNTAX GenAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source address is according to the maskingMacOrNet and
|
|
maskingProtocolType variables.
|
|
In case of 'MAC' enter 6 bytes (48 bit) of source address.
|
|
In case of 'NET'
|
|
if the maskingProtocolType is IP, this is the IP address
|
|
if the maskingProtocolType is IPX, this is the IPX address
|
|
(nnnnmmmmmmss)
|
|
nnnn - IPX net address
|
|
mmmmmm - Node address (Mac)
|
|
ss - IPX socket
|
|
In case of 'Apple'
|
|
nn - net address (4 nibbles)
|
|
ss - socket (4 nibbles)."
|
|
::= { maskingEntry 8 }
|
|
|
|
maskingSourceActiveBits OBJECT-TYPE
|
|
SYNTAX GenAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the positions of the wild card characters (*)
|
|
in the maskingSourceAddress field. Only the 1's bit will be taken in
|
|
considerations."
|
|
::= { maskingEntry 9 }
|
|
|
|
maskingSourceMacOrNet OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
macAddress (1),
|
|
netAddress (2),
|
|
ipRange (3),
|
|
appleAddress(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The variable maskingSourceAddress and maskingSourceActiveBits
|
|
will be treated as MAC, or NET address.
|
|
- If maskingProtocolType = 'all', 'sna', 'netbios', dec or
|
|
'unknown', the maskingSourceMacOrNet can be macAddress only!
|
|
- If maskingProtocolType = 'ip' the
|
|
maskingSourceMacOrNet can be macAddress or netAddress or
|
|
appleAddress.
|
|
- If maskingProtocolType = 'ipx', the
|
|
maskingSourceMacOrNet can be either macAddress or netAddress.
|
|
- If maskingProtocolType = 'apple', the
|
|
maskingSourceMacOrNet can be either macAddress or appleAddress."
|
|
::= { maskingEntry 10 }
|
|
|
|
maskingSourceCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
maskingSourceAddress (in conjunction with maskingSourceActiveBits)
|
|
the packet contains data that matches the content of maskingSourceAddress.
|
|
|
|
false - Condition is valid if at the position specified by
|
|
maskingSourceAddress (in conjunction with maskingSourceActiveBits)
|
|
the packet contains data that does not match the content of
|
|
maskingSourceAddress."
|
|
::= { maskingEntry 11 }
|
|
|
|
maskingDestAddress OBJECT-TYPE
|
|
SYNTAX GenAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If maskingFrameType = broadcast or multicast, this object
|
|
is NOT APPLICABLE.
|
|
If maskingFrameType = all or unknown, this object is
|
|
applicable.
|
|
The destination address is according to the maskingMacOrNet and maskingProtocolType variables.
|
|
In case of 'MAC' enter 6 bytes (48 bit) of source address.
|
|
In case of 'NET'
|
|
if the maskingProtocolType is IP, this is the IP address
|
|
if the maskingProtocolType is IPX, this is the IPX address
|
|
(nnnnmmmmmmss)
|
|
nnnn - IPX net address
|
|
mmmmmm - Node address (Mac)
|
|
ss - IPX socket.
|
|
In case of 'Apple'
|
|
nn - net address (4 nibbles)
|
|
ss - socket (4 nibbles).
|
|
The IPX socket entered here has priority over the value of
|
|
maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx,
|
|
unless the entered IPX socket is don't care. "
|
|
::= { maskingEntry 12 }
|
|
|
|
maskingDestActiveBits OBJECT-TYPE
|
|
SYNTAX GenAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If maskingFrameType = broadcast or multicast, this object
|
|
is NOT APPLICABLE.
|
|
If maskingFrameType = all or unknown, this object is
|
|
applicable.
|
|
Specifies the positions of the wild card characters (*)
|
|
in the maskingDestAddress field. Only the 1's bit will be taken in
|
|
considerations."
|
|
::= { maskingEntry 13 }
|
|
|
|
maskingDestMacOrNet OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
macAddress (1),
|
|
netAddress (2),
|
|
ipRange (3),
|
|
appleAddress(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If maskingFrameType = broadcast or multicast, this object
|
|
is NOT APPLICABLE.
|
|
If maskingFrameType = all or unknown, this object is
|
|
applicable.
|
|
- If maskingProtocolType = 'all', 'sna', 'netbios', dec or
|
|
'unknown', the maskingDestMacOrNet can be macAddress only!
|
|
- If maskingProtocolType = 'ip' the
|
|
maskingDestMacOrNet can be macAddress or netAddress or
|
|
appleAddress.
|
|
- If maskingProtocolType = 'ipx', the
|
|
maskingDestMacOrNet can be either macAddress or netAddress.
|
|
- If maskingProtocolType = 'apple', the
|
|
maskingDestMacOrNet can be either macAddress or appleAddress.
|
|
The variable maskingDestAddress and maskingDestActiveBits will
|
|
be treated as MAC, or NET address. "
|
|
::= { maskingEntry 14 }
|
|
|
|
maskingDestCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If maskingFrameType = broadcast or multicast, this object
|
|
is NOT APPLICABLE.
|
|
If maskingFrameType = all or unknown, this object is
|
|
applicable.
|
|
Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
maskingDestAddress (in conjunction with maskingDestActiveBits)
|
|
the packet contains data that matches the content of maskingDestAddress.
|
|
|
|
false - Condition is valid if at the position specified by
|
|
maskingDestAddress (in conjunction with maskingDestActiveBits)
|
|
the packet contains data that does not match the content of maskingDestAddress."
|
|
::= { maskingEntry 15 }
|
|
|
|
maskingLowLevelProt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1), -- don't care
|
|
ipxRip (2), -- 0x51
|
|
ipxSap (3), -- 0x52
|
|
ipxSpx (4), -- 0x53
|
|
ipUdp (5), -- 0x54
|
|
ipTcp (6), -- 0x55
|
|
ipIcmp (7), -- 0x56
|
|
ipxNcp (8), -- 0x57
|
|
ipxWan (9), -- 0x58
|
|
ipxEco (10), -- 0x59
|
|
ipxErr (11), -- 0x5a
|
|
ipxPep (12) -- 0x5b
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field is set in conjunction with the maskingProtocolType variable.
|
|
This variable specifies the low level protocol.
|
|
The IPX socket entered in maskingDestAddress has priority
|
|
over the value of maskingLowLevelProt, when it is ipxRip,
|
|
ipxSap or ipxSpx, unless the entered IPX socket is don't
|
|
care."
|
|
::= { maskingEntry 16 }
|
|
|
|
maskingLowLevelProtCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
maskingLowLevelProt the packet contains data that matches
|
|
the content of maskingLowLevelProt.
|
|
|
|
false - Condition is valid if at the position specified by
|
|
maskingLowLevelProt the packet contains data that does not
|
|
match the content of maskingLowLevelProt."
|
|
::= { maskingEntry 17 }
|
|
|
|
maskingHighLevelProt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field is set in connection to the maskingProtocolType variable.
|
|
This variable specifies the high level protocols (application).
|
|
As for today it supports just IP protocol stack.
|
|
The object's value is a sum of the following instances values
|
|
(selected by user):
|
|
none (0), -- don't care
|
|
ftp (1),
|
|
ftpC (2),
|
|
telnet (4),
|
|
smtp (8),
|
|
tftp (16),
|
|
snmp (32),
|
|
snmpTrap (64),
|
|
ipRip (128),
|
|
www (256),
|
|
email (512),
|
|
dns (1024),
|
|
|
|
For Apple Protocol only:
|
|
rtmp (2048),
|
|
nbp (4096),
|
|
atp (8192),
|
|
aep (16384),
|
|
zip (32768),
|
|
adsp (65536),
|
|
pap (131072),
|
|
asp (262144)
|
|
|
|
Example: if ftp(1), snmp(32) and snmpTrap(64) instances
|
|
were selected, the value should be 97 (=1+32+64)."
|
|
::= { maskingEntry 18 }
|
|
|
|
maskingHighLevelProtCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
maskingHighLevelProt the packet contains data that matches
|
|
the content of maskingHighLevelProt.
|
|
|
|
false - Condition is valid if at the position specified by
|
|
maskingHighLevelProt the packet contains data that does not
|
|
match the content of maskingHighLevelProt."
|
|
::= { maskingEntry 19 }
|
|
|
|
maskingPortNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number is the same as in high level protocol. It
|
|
specifies the dest. port in IP case or the dest. socket
|
|
in case of IPX & apple protocols.
|
|
IP - This object is applicable only if none (0) value was selected in
|
|
maskingHighLevelProt.
|
|
IPX - This object is applicable only if the socket
|
|
entered in maskingDestAddress is 'don't care'(00) AND
|
|
maskingLowLevelProt is NOT ipxRip or ipxSap.
|
|
Apple - This option is applicable only if the socket
|
|
entered in maskingDestAddress is 'don't care'(00)."
|
|
::= { maskingEntry 20 }
|
|
|
|
maskingPortNumCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the logical condition of the mask pattern:
|
|
|
|
true - Condition is valid if at the position specified by
|
|
maskingPortNum the packet contains data that matches
|
|
the content of maskingPortNum.
|
|
|
|
false - Condition is valid if at the position specified by
|
|
maskingPortNum the packet contains data that does not
|
|
match the content of maskingPortNum.
|
|
This object is applicable only when maskingPortNum is applicable."
|
|
::= { maskingEntry 21 }
|
|
|
|
|
|
maskingOperation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
block (1),
|
|
forward (2),
|
|
route (3),
|
|
forward-route (4),
|
|
high-priority (5),
|
|
noOp (6),
|
|
delete (7),
|
|
smartMask (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of action to be taken if the frame meets the
|
|
conditions of the mask.
|
|
noOp = disabled (mask remains on list, but is not active)
|
|
delete = mask is removed from the list.
|
|
smartMask = the operation and destination of the mask will
|
|
be determined by the objects of the Smart Table
|
|
(old masking table: radBridgeMaskTable).
|
|
If maskingType is codConnect, the 'block' value is NOT
|
|
allowed.
|
|
If maskingType is codDisconnect, the 'forward' value is NOT
|
|
allowed."
|
|
::= { maskingEntry 22 }
|
|
|
|
maskingSrcPortNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source port number.
|
|
For IP: No Condition.
|
|
For IPX: This object is applicable only if the socket entered in
|
|
maskingSourceAddress is don't care (00) and maskingLowLevelProt
|
|
is NOT ipxRip or ipxSap.
|
|
For Apple:This object is applicable only if the socket entered in
|
|
maskingSourceAddress is don't care (00). "
|
|
::= { maskingEntry 23 }
|
|
|
|
maskingSrcPortNumCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false (1),
|
|
true (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The same as 'maskingPortNumCondition'.
|
|
Relates to source port."
|
|
::= { maskingEntry 24 }
|
|
|
|
|
|
radBridgePerformance OBJECT IDENTIFIER ::= {genBridge 7 }
|
|
|
|
-- The RAD Bridge current table contains statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
radBridgeCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RAD Bridge Current table."
|
|
::= { radBridgePerformance 1 }
|
|
|
|
radBridgeCurrentEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the RAD Bridge Current table."
|
|
INDEX { radBridgeCurrentIndex }
|
|
::= { radBridgeCurrentTable 1 }
|
|
|
|
RadBridgeCurrentEntry ::=
|
|
SEQUENCE {
|
|
radBridgeCurrentIndex
|
|
Integer32,
|
|
radBridgeCurrentIngressFilteringDiscardedFrames
|
|
Gauge32,
|
|
radBridgeCurrentFrameTypeDiscardedFrames
|
|
Gauge32
|
|
}
|
|
|
|
radBridgeCurrentIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the Bridge interface.
|
|
It may be ifIndex."
|
|
::= { radBridgeCurrentEntry 1 }
|
|
|
|
radBridgeCurrentIngressFilteringDiscardedFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Discarded
|
|
Frames upon Ingress Filtering, encountered by a Bridge
|
|
interface in the current 15 minute interval."
|
|
::= { radBridgeCurrentEntry 2 }
|
|
|
|
radBridgeCurrentFrameTypeDiscardedFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Discarded
|
|
Frames upon Frame Type and Tagging Mismatch, encountered
|
|
by a Bridge interface in the current 15 minute interval."
|
|
::= { radBridgeCurrentEntry 3 }
|
|
|
|
|
|
|
|
--Interval Table
|
|
|
|
-- The RAD Bridge Interval table contains statistics being
|
|
-- collected by each Interface over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
radBridgeIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RAD Bridge Interval table."
|
|
::= { radBridgePerformance 2 }
|
|
|
|
radBridgeIntervalEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the RAD Bridge Interval table."
|
|
INDEX { radBridgeIntervalIndex, radBridgeIntervalNumber }
|
|
::= { radBridgeIntervalTable 1 }
|
|
|
|
RadBridgeIntervalEntry ::=
|
|
SEQUENCE {
|
|
radBridgeIntervalIndex
|
|
Integer32,
|
|
radBridgeIntervalNumber
|
|
Integer32,
|
|
radBridgeIntervalIngressFilteringDiscardedFrames
|
|
Gauge32,
|
|
radBridgeIntervalFrameTypeDiscardedFrames
|
|
Gauge32
|
|
}
|
|
|
|
radBridgeIntervalIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the bridge interface.
|
|
It may be ifIndex."
|
|
::= { radBridgeIntervalEntry 1 }
|
|
|
|
radBridgeIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals exist)."
|
|
::= { radBridgeIntervalEntry 2 }
|
|
|
|
radBridgeIntervalIngressFilteringDiscardedFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Discarded
|
|
Frames upon Ingress Filtering, encountered by a
|
|
Bridge interface in one of the previous 96, individual
|
|
15 minute, intervals."
|
|
::= { radBridgeIntervalEntry 3 }
|
|
|
|
radBridgeIntervalFrameTypeDiscardedFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Discarded
|
|
Frames upon Frame Type and Tagging Mismatch, encountered
|
|
by a Bridge interface in one of the previous 96, individual
|
|
15 minute, intervals."
|
|
::= { radBridgeIntervalEntry 4 }
|
|
|
|
|
|
radBridgePortBaseVlan OBJECT IDENTIFIER ::= {genBridge 8 }
|
|
|
|
radBridgePortBaseVlanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgePortBaseVlanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing static configuration information for
|
|
each VLAN configured into the device by management.
|
|
All entries are permanent and will
|
|
be restored after the device is reset."
|
|
::= { radBridgePortBaseVlan 1 }
|
|
|
|
radBridgePortBaseVlanEntry OBJECT-TYPE
|
|
SYNTAX RadBridgePortBaseVlanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Static information for a VLAN configured into the
|
|
device by (local or network) management."
|
|
INDEX { radBridgePortBaseVlanCnfgIdx,radBridgePortBaseVlanIdx }
|
|
::= { radBridgePortBaseVlanTable 1 }
|
|
|
|
RadBridgePortBaseVlanEntry ::=
|
|
SEQUENCE {
|
|
radBridgePortBaseVlanCnfgIdx Integer32,
|
|
radBridgePortBaseVlanIdx Integer32,
|
|
radBridgePortBaseVlanName SnmpAdminString,
|
|
radBridgePortBaseVlanEgressPorts PortList,
|
|
radBridgePortBaseVlanVirtualGroups PortList,
|
|
radBridgePortBaseVlanRowStatus RowStatus,
|
|
radBridgePortBaseVlanMng INTEGER
|
|
}
|
|
|
|
radBridgePortBaseVlanCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Agent Cnfg the following
|
|
objects refer.
|
|
255=Temporary Cnfg (when relevant,
|
|
Set is done only to this configuration).
|
|
For Agents that support only one configuration,
|
|
this object will be constant=1. "
|
|
::= { radBridgePortBaseVlanEntry 1 }
|
|
|
|
radBridgePortBaseVlanIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the port based VLAN."
|
|
::= { radBridgePortBaseVlanEntry 2 }
|
|
|
|
radBridgePortBaseVlanName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An administratively assigned string, which may be used
|
|
to identify the the port based VLAN."
|
|
::= { radBridgePortBaseVlanEntry 3 }
|
|
|
|
radBridgePortBaseVlanEgressPorts OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The set of ports which are permanently assigned to the
|
|
egress list for this port based VLAN by management.
|
|
The default value of this object is a string of zeros."
|
|
::= { radBridgePortBaseVlanEntry 4 }
|
|
|
|
|
|
radBridgePortBaseVlanVirtualGroups OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The set of Virtual Groups which are permanently assigned to
|
|
this port based VLAN by management.
|
|
(read Virtual Group instead of port in PortList Textual Convention)
|
|
The default value of this object is a string of zeros."
|
|
::= { radBridgePortBaseVlanEntry 5 }
|
|
|
|
|
|
radBridgePortBaseVlanRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enable user to
|
|
create/delete entries in this table."
|
|
::= { radBridgePortBaseVlanEntry 6 }
|
|
|
|
radBridgePortBaseVlanMng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows user to enable/disable
|
|
management traffic on this VLAN."
|
|
::= { radBridgePortBaseVlanEntry 7 }
|
|
|
|
|
|
-- The Bridge's Ports-VLANs Memebership Table
|
|
|
|
radBridgePortVlanMemberTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgePortVlanMemberEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bridge Ports-VLAN Membership table.
|
|
This table enables the user to assign:
|
|
- Several VLANs to a Port.
|
|
- Several Ports to a VLAN."
|
|
::= { radBridgePortBaseVlan 2 }
|
|
|
|
radBridgePortVlanMemberEntry OBJECT-TYPE
|
|
SYNTAX RadBridgePortVlanMemberEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Bridge Ports-VLANs Memebership table."
|
|
INDEX { radBridgePortVlanMemberBridgeIdx,
|
|
radBridgePortVlanMemberPortIdx,
|
|
radBridgePortVlanMemberVlanId }
|
|
::= { radBridgePortVlanMemberTable 1 }
|
|
|
|
RadBridgePortVlanMemberEntry ::=
|
|
SEQUENCE {
|
|
radBridgePortVlanMemberBridgeIdx Integer32,
|
|
radBridgePortVlanMemberPortIdx Integer32,
|
|
radBridgePortVlanMemberVlanId Integer32,
|
|
radBridgePortVlanMemberRowStatus RowStatus
|
|
}
|
|
|
|
radBridgePortVlanMemberBridgeIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Bridge Index."
|
|
::= { radBridgePortVlanMemberEntry 1 }
|
|
|
|
radBridgePortVlanMemberPortIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Bridge's Port Index.
|
|
For some cases, it can be used as the Port ofIndex."
|
|
::= { radBridgePortVlanMemberEntry 2 }
|
|
|
|
radBridgePortVlanMemberVlanId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the VLAN ID."
|
|
::= { radBridgePortVlanMemberEntry 3 }
|
|
|
|
radBridgePortVlanMemberRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables the user to
|
|
create/delete entries in this table."
|
|
::= { radBridgePortVlanMemberEntry 4 }
|
|
|
|
radBridgeGenCnfg OBJECT IDENTIFIER ::= {genBridge 9 }
|
|
|
|
|
|
radBridgeGenFlowTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeGenFlowEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing static configuration information for
|
|
Bridge configured into the device by (local or
|
|
network) management. All entries are permanent and will
|
|
be restored after the device is reset."
|
|
::= { radBridgeGenCnfg 1 }
|
|
|
|
radBridgeGenFlowEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeGenFlowEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Static information for a Bridge configured into the
|
|
device by management."
|
|
INDEX { radBridgeGenFlowCnfgIdx,radBridgeGenFlowIdx }
|
|
::= { radBridgeGenFlowTable 1 }
|
|
|
|
RadBridgeGenFlowEntry ::=
|
|
SEQUENCE
|
|
{
|
|
radBridgeGenFlowCnfgIdx Integer32,
|
|
radBridgeGenFlowIdx Integer32,
|
|
radBridgeGenFlowRowStatus RowStatus,
|
|
radBridgeGenFlowFloodOrBcastMaxRate Integer32,
|
|
radBridgeGenFlowQosMode INTEGER,
|
|
radBridgeGenFlowSchedulingMode INTEGER
|
|
|
|
}
|
|
|
|
radBridgeGenFlowCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the
|
|
Agent Cnfg the following objects refer.
|
|
255=Temporary Cnfg (when relevant,
|
|
|
|
Set is done only to this configuration).
|
|
For Agents that support only one configuration,
|
|
this object will be constant=1. "
|
|
::= { radBridgeGenFlowEntry 1 }
|
|
|
|
radBridgeGenFlowIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For Agent having more than one bridge,
|
|
this index may be used as bridge index "
|
|
::= { radBridgeGenFlowEntry 2 }
|
|
|
|
radBridgeGenFlowRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enable user to
|
|
create/delete entries in this table."
|
|
::= { radBridgeGenFlowEntry 3 }
|
|
|
|
|
|
radBridgeGenFlowFloodOrBcastMaxRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls maximum Flooding or Broadcast Rate:
|
|
Max number of multicast along with unknown
|
|
or flooded unicast frames allowed to enter
|
|
any port.
|
|
The number is presented as percentage of bandwidth.
|
|
Once the limit is exceeded, any multicast or flooded
|
|
frame entering from the port is discarded
|
|
For RIC-155 valid values are 0-100
|
|
For FCD-155 valid values are 3% , 6%, 12%
|
|
and 100% = No Limit "
|
|
::= { radBridgeGenFlowEntry 4 }
|
|
|
|
|
|
radBridgeGenFlowQosMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
vlanTag (2),
|
|
dscp (3),
|
|
dscpAndVlanTag (4),
|
|
vlanTagAndDscp (5),
|
|
none (6)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls Quality of Service mode.
|
|
User may select which field(s)
|
|
(in case of fields - which one has precedence)
|
|
will affect prioritization of data between egress queues."
|
|
::= { radBridgeGenFlowEntry 5 }
|
|
|
|
radBridgeGenFlowSchedulingMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
wfq (2), -- Weighted Fair Queuing
|
|
sp (3) -- Strict Priority
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls which scheduling mode is used:
|
|
Weighted Fair Queuing (WFQ) scheme or Strict Priority (SP)."
|
|
::= { radBridgeGenFlowEntry 6 }
|
|
|
|
radBridgeStatus OBJECT IDENTIFIER ::= {genBridge 10 }
|
|
|
|
radBridgeInvBasePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RadBridgeInvBasePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An inversed table to dot1dBasePortTable
|
|
from RFC1493 with reduced information.
|
|
This table index is known to the NMS and
|
|
this way the needed information can be received
|
|
by just one Get command, instead of searching
|
|
the entire dot1dBasePortTable (where it is an
|
|
attribute). "
|
|
::= { radBridgeStatus 1 }
|
|
|
|
radBridgeInvBasePortEntry OBJECT-TYPE
|
|
SYNTAX RadBridgeInvBasePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bridge port number for each bridge port
|
|
interface index."
|
|
INDEX { radBridgeInvBasePortIfIndex }
|
|
::= { radBridgeInvBasePortTable 1 }
|
|
|
|
RadBridgeInvBasePortEntry ::=
|
|
SEQUENCE {
|
|
radBridgeInvBasePortIfIndex Integer32,
|
|
radBridgeInvBasePort Integer32
|
|
}
|
|
|
|
radBridgeInvBasePortIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the instance of the ifIndex object,
|
|
defined in MIB-II, for the interface corresponding
|
|
to this Bridge port."
|
|
::= { radBridgeInvBasePortEntry 1 }
|
|
|
|
radBridgeInvBasePort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bridge port number."
|
|
::= { radBridgeInvBasePortEntry 2 }
|
|
|
|
|
|
-- END --
|
|
-- file :v:\doc\rdv\mib\ver495\radsonet.txt
|
|
--
|
|
-- RAD-SONET-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--Title: RAD-SONET MIB ver495
|
|
--
|
|
|
|
-- IMPORTS
|
|
-- Gauge32 FROM RFC1155-SMI
|
|
-- ifIndex FROM RFC1213-MIB
|
|
-- OBJECT-TYPE FROM RFC-1212
|
|
-- radWan FROM RAD-GEN-MIB;
|
|
|
|
|
|
|
|
-- RAD-SONET MIB
|
|
|
|
--Title: RAD's SONET INTERFACE MIB
|
|
--Version: 1.0
|
|
--Date: 13.10.96
|
|
--By: Yair Arian
|
|
--File: sonet.mib
|
|
--
|
|
--Last update: 25-Septemper-2002 by Yig'al Hachmon
|
|
|
|
|
|
|
|
sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2}
|
|
|
|
prtSonetPerfHistory OBJECT IDENTIFIER ::= {sonetInterface 1}
|
|
|
|
|
|
-- The SONET Medium Table
|
|
|
|
prtSonetMediumTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSonetMediumEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SONET Medium table."
|
|
::= { prtSonetPerfHistory 1 }
|
|
|
|
prtSonetMediumEntry OBJECT-TYPE
|
|
SYNTAX PrtSonetMediumEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the SONET Medium table. ifIndex of the
|
|
lowest SONET layer of type sonet(39)."
|
|
INDEX { ifIndex }
|
|
::= { prtSonetMediumTable 1 }
|
|
|
|
PrtSonetMediumEntry ::=
|
|
SEQUENCE {
|
|
prtSonetMediumTimeElapsed
|
|
Integer32,
|
|
prtSonetMediumValidIntervals
|
|
Integer32
|
|
}
|
|
|
|
prtSonetMediumTimeElapsed OBJECT-TYPE
|
|
SYNTAX Integer32 (0..899)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds that have elapsed since
|
|
the beginning of the near end current error-
|
|
measurement period."
|
|
::= { prtSonetMediumEntry 1 }
|
|
|
|
prtSonetMediumValidIntervals OBJECT-TYPE
|
|
SYNTAX Integer32 (0..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of previous near end intervals for
|
|
which valid data was collected. The value will be
|
|
96 unless the interface was brought online within
|
|
the last 24 hours, in which case the value will be
|
|
the number of complete 15 minute near end
|
|
intervals since the interface has been online."
|
|
::= { prtSonetMediumEntry 2 }
|
|
|
|
|
|
-- The SONET Section/Line Current Table
|
|
|
|
-- The SONET Section/Line Current table contains various statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
prtSonetSectionLineCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSectionLineCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SONET Section/Line Current table."
|
|
::= { prtSonetPerfHistory 2 }
|
|
|
|
prtSectionLineCurrentEntry OBJECT-TYPE
|
|
SYNTAX PrtSectionLineCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the SONET Section/Line Current table.
|
|
ifIndex of the section/line SONET layer of type
|
|
sonet(39)."
|
|
INDEX { ifIndex }
|
|
::= { prtSonetSectionLineCurrentTable 1 }
|
|
|
|
PrtSectionLineCurrentEntry ::=
|
|
SEQUENCE {
|
|
prtSonetCurrentLOS
|
|
Gauge32,
|
|
prtSonetCurrentLOF
|
|
Gauge32,
|
|
prtSonetCurrentLineAIS
|
|
Gauge32,
|
|
prtSonetCurrentLineFERF
|
|
Gauge32,
|
|
prtSonetCurrentSectionBIP
|
|
Gauge32,
|
|
prtSonetCurrentLineBIP
|
|
Gauge32,
|
|
prtSonetCurrentLineFEBE
|
|
Gauge32,
|
|
prtSonetCurrentUAS
|
|
Gauge32,
|
|
prtSonetCurrentSES
|
|
Gauge32,
|
|
prtSonetCurrentES
|
|
Gauge32,
|
|
prtSonetCurrentStatus
|
|
OCTET STRING,
|
|
prtSonetCurrentLSV
|
|
Gauge32
|
|
|
|
}
|
|
|
|
prtSonetCurrentLOS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOS
|
|
seconds, encountered by a SONET interface in
|
|
the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 1 }
|
|
|
|
prtSonetCurrentLOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOF
|
|
seconds, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 2 }
|
|
|
|
prtSonetCurrentLineAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line AIS
|
|
seconds, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 3 }
|
|
|
|
prtSonetCurrentLineFERF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line
|
|
FERF seconds, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 4 }
|
|
|
|
prtSonetCurrentSectionBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Section
|
|
BIP errors, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 5 }
|
|
|
|
prtSonetCurrentLineBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line
|
|
BIP errors, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 6 }
|
|
|
|
prtSonetCurrentLineFEBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line
|
|
FEBE errors, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 7 }
|
|
|
|
prtSonetCurrentUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of UAS
|
|
encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 8 }
|
|
|
|
prtSonetCurrentSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SES
|
|
encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 9 }
|
|
|
|
prtSonetCurrentES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Errored Seconds, encountered by a
|
|
SONET interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 10 }
|
|
|
|
prtSonetCurrentStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - O.K.
|
|
1 - The link has been switched by a redundancy mechanism.
|
|
2 - Module is in/out.
|
|
4 - Empty - card is out."
|
|
::= { prtSectionLineCurrentEntry 11 }
|
|
|
|
prtSonetCurrentLSV OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LSV
|
|
seconds (Line Symbol Violation), encountered by a
|
|
SONET interface in the current 15 minute interval."
|
|
::= { prtSectionLineCurrentEntry 12 }
|
|
|
|
|
|
-- The SONET Section/Line interface Interval
|
|
|
|
-- The SONET Section/Line Interval Table contains various statistics
|
|
-- collected by the Interface over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
prtSonetSectionLineIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSectionLineIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Section/Line Interval table."
|
|
::= { prtSonetPerfHistory 3 }
|
|
|
|
prtSectionLineIntervalEntry OBJECT-TYPE
|
|
SYNTAX PrtSectionLineIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the SONET Section/Line Interval table.
|
|
ifIndex of the section/line SONET layer of type
|
|
sonet(39)."
|
|
INDEX { ifIndex, prtSonetLineIntervalNumber }
|
|
::= { prtSonetSectionLineIntervalTable 1 }
|
|
|
|
PrtSectionLineIntervalEntry ::=
|
|
SEQUENCE {
|
|
prtSonetLineIntervalNumber
|
|
Integer32,
|
|
prtSonetIntervalLOS
|
|
Gauge32,
|
|
prtSonetIntervalLOF
|
|
Gauge32,
|
|
prtSonetIntervalLineAIS
|
|
Gauge32,
|
|
prtSonetIntervalLineFERF
|
|
Gauge32,
|
|
prtSonetIntervalSectionBIP
|
|
Gauge32,
|
|
prtSonetIntervalLineBIP
|
|
Gauge32,
|
|
prtSonetIntervalLineFEBE
|
|
Gauge32,
|
|
prtSonetIntervalUAS
|
|
Gauge32,
|
|
prtSonetIntervalSES
|
|
Gauge32,
|
|
prtSonetIntervalES
|
|
Gauge32,
|
|
prtSonetIntervalStatus
|
|
OCTET STRING,
|
|
prtSonetIntervalLSV
|
|
Gauge32 }
|
|
|
|
prtSonetLineIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { prtSectionLineIntervalEntry 1 }
|
|
|
|
prtSonetIntervalLOS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOS
|
|
seconds , encountered by a SONET interface in
|
|
one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { prtSectionLineIntervalEntry 2 }
|
|
|
|
prtSonetIntervalLOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOF
|
|
seconds, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 3 }
|
|
|
|
prtSonetIntervalLineAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line
|
|
AIS seconds, encountered by a SONET
|
|
interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 4 }
|
|
|
|
prtSonetIntervalLineFERF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line
|
|
FERF seconds, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 5 }
|
|
|
|
prtSonetIntervalSectionBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Section
|
|
BIP errors, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 6 }
|
|
|
|
prtSonetIntervalLineBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line
|
|
BIP errors, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 7 }
|
|
|
|
prtSonetIntervalLineFEBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Line
|
|
FEBE errors, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 8 }
|
|
|
|
prtSonetIntervalUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of UAS
|
|
encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 9 }
|
|
|
|
prtSonetIntervalSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SES
|
|
encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 10 }
|
|
|
|
prtSonetIntervalES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Errored Seconds, encountered by a
|
|
SONET interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 11 }
|
|
|
|
prtSonetIntervalStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The statuses of the current interval:
|
|
0 - O.K.
|
|
1 - The link has been switched by a redundancy mechanism.
|
|
2 - Module is in/out.
|
|
4 - Empty - card is out."
|
|
::= { prtSectionLineIntervalEntry 12 }
|
|
|
|
prtSonetIntervalLSV OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LSV seconds
|
|
(Line Symbol Violation), encountered by a SONET interface
|
|
in one of the previous 96, individual 15 minute, intervals."
|
|
::= { prtSectionLineIntervalEntry 13 }
|
|
|
|
|
|
-- The SONET Path Current Table
|
|
|
|
-- The SONET Path Current table contains various statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
prtSonetPathCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtPathCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SONET Path Current table."
|
|
::= { prtSonetPerfHistory 4 }
|
|
|
|
prtPathCurrentEntry OBJECT-TYPE
|
|
SYNTAX PrtPathCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the SONET Path Current table.
|
|
ifIndex of the Path SONET layer of type
|
|
sonetPath(50)."
|
|
INDEX { ifIndex }
|
|
::= { prtSonetPathCurrentTable 1 }
|
|
|
|
PrtPathCurrentEntry ::=
|
|
SEQUENCE {
|
|
prtSonetCurrentPathAIS
|
|
Gauge32,
|
|
prtSonetCurrentPathFERF
|
|
Gauge32,
|
|
prtSonetCurrentLOP
|
|
Gauge32,
|
|
prtSonetCurrentSLM
|
|
Gauge32,
|
|
prtSonetCurrentLOC
|
|
Gauge32,
|
|
prtSonetCurrentPathBIP
|
|
Gauge32,
|
|
prtSonetCurrentPathFEBE
|
|
Gauge32
|
|
}
|
|
|
|
prtSonetCurrentPathAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Path AIS
|
|
seconds, encountered by a SONET interface in
|
|
the current 15 minute interval."
|
|
::= { prtPathCurrentEntry 1 }
|
|
|
|
prtSonetCurrentPathFERF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Path FERF
|
|
seconds, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtPathCurrentEntry 2 }
|
|
|
|
prtSonetCurrentLOP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number LOP
|
|
seconds, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtPathCurrentEntry 3 }
|
|
|
|
prtSonetCurrentSLM OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SLM
|
|
seconds, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtPathCurrentEntry 4 }
|
|
|
|
prtSonetCurrentLOC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOC
|
|
seconds, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtPathCurrentEntry 5 }
|
|
|
|
prtSonetCurrentPathBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Path
|
|
BIP errors, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtPathCurrentEntry 6 }
|
|
|
|
prtSonetCurrentPathFEBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Path
|
|
FEBE errors, encountered by a SONET
|
|
interface in the current 15 minute interval."
|
|
::= { prtPathCurrentEntry 7 }
|
|
|
|
|
|
-- The SONET Path interface Interval
|
|
|
|
-- The SONET Path Interval Table contains various statistics
|
|
-- collected by the Interface over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
prtSonetPathIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtPathIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Path Interval table."
|
|
::= { prtSonetPerfHistory 5 }
|
|
|
|
prtPathIntervalEntry OBJECT-TYPE
|
|
SYNTAX PrtPathIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the SONET Path Interval table."
|
|
INDEX { ifIndex, prtSonetPathIntervalNumber }
|
|
::= { prtSonetPathIntervalTable 1 }
|
|
|
|
PrtPathIntervalEntry ::=
|
|
SEQUENCE {
|
|
prtSonetPathIntervalNumber
|
|
Integer32,
|
|
prtSonetIntervalPathAIS
|
|
Gauge32,
|
|
prtSonetIntervalPathFERF
|
|
Gauge32,
|
|
prtSonetIntervalLOP
|
|
Gauge32,
|
|
prtSonetIntervalSLM
|
|
Gauge32,
|
|
prtSonetIntervalLOC
|
|
Gauge32,
|
|
prtSonetIntervalPathBIP
|
|
Gauge32,
|
|
prtSonetIntervalPathFEBE
|
|
Gauge32
|
|
}
|
|
|
|
prtSonetPathIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { prtPathIntervalEntry 1 }
|
|
|
|
prtSonetIntervalPathAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Path
|
|
AIS seconds , encountered by a SONET interface in
|
|
one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { prtPathIntervalEntry 2 }
|
|
|
|
prtSonetIntervalPathFERF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Path
|
|
FERF seconds, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtPathIntervalEntry 3 }
|
|
|
|
prtSonetIntervalLOP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOP
|
|
seconds, encountered by a SONET
|
|
interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { prtPathIntervalEntry 4 }
|
|
|
|
prtSonetIntervalSLM OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SLM
|
|
seconds, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtPathIntervalEntry 5 }
|
|
|
|
prtSonetIntervalLOC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of LOC
|
|
seconds, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtPathIntervalEntry 6 }
|
|
|
|
prtSonetIntervalPathBIP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Path
|
|
BIP errors, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtPathIntervalEntry 7 }
|
|
|
|
prtSonetIntervalPathFEBE OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Path
|
|
FEBE errors, encountered by a SONET
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { prtPathIntervalEntry 8 }
|
|
|
|
|
|
|
|
virtualIfStatistics OBJECT IDENTIFIER ::= { prtSonetPerfHistory 6}
|
|
|
|
|
|
-- the Virtual Interface Current Table
|
|
|
|
virtualIfCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VirtualIfCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Interface Current table."
|
|
::= { virtualIfStatistics 1 }
|
|
|
|
virtualIfCurrentEntry OBJECT-TYPE
|
|
SYNTAX VirtualIfCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Interface Current table."
|
|
INDEX { ifIndex }
|
|
::= { virtualIfCurrentTable 1 }
|
|
|
|
VirtualIfCurrentEntry ::=
|
|
SEQUENCE {
|
|
virtualIfCurrentMinActiveVC Integer32,
|
|
virtualIfCurrentMaxActiveVC Integer32,
|
|
virtualIfCurrentRxFrames Counter64,
|
|
virtualIfCurrentTxFrames Counter64,
|
|
virtualIfCurrentRxAbortFrames PerfCurrentCount,
|
|
virtualIfCurrentTxAbortFrames PerfCurrentCount,
|
|
virtualIfCurrentMinLengthViolation PerfCurrentCount,
|
|
virtualIfCurrentMaxLengthViolation PerfCurrentCount,
|
|
virtualIfCurrentFcsError PerfCurrentCount,
|
|
virtualIfCurrentByteDestuffingViolation PerfCurrentCount,
|
|
virtualIfCurrentAdressMismatch PerfCurrentCount,
|
|
virtualIfCurrentControlMismatch PerfCurrentCount,
|
|
virtualIfCurrentActiveVC Integer32
|
|
|
|
}
|
|
|
|
virtualIfCurrentMinActiveVC OBJECT-TYPE
|
|
SYNTAX Integer32 (1..63)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the minimum number of active virtual containers (VCs)
|
|
of the Virtual Concatenation Group in the current 15-minute interval."
|
|
::= { virtualIfCurrentEntry 1 }
|
|
|
|
virtualIfCurrentMaxActiveVC OBJECT-TYPE
|
|
SYNTAX Integer32 (1..63)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the maximum number of active virtual containers (VCs)
|
|
of the Virtual Concatenation Group in the current 15-minute interval."
|
|
::= {virtualIfCurrentEntry 2 }
|
|
|
|
virtualIfCurrentRxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of frames received from STS-3/STM-1
|
|
by a Virtual Interface in the current 15-minute interval."
|
|
::= { virtualIfCurrentEntry 3}
|
|
|
|
virtualIfCurrentTxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of frames transmitted to STS-3/STM-1
|
|
by a Virtual Interface in the current 15-minute interval."
|
|
::= { virtualIfCurrentEntry 4 }
|
|
|
|
virtualIfCurrentRxAbortFrames OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Received Aborted frames
|
|
encountered by a Virtual Interface in the current 15-minute interval."
|
|
::= { virtualIfCurrentEntry 5 }
|
|
|
|
virtualIfCurrentTxAbortFrames OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Transmitted Aborted frames
|
|
encountered by a Virtual Interface in the current 15-minute interval."
|
|
::= { virtualIfCurrentEntry 6 }
|
|
|
|
virtualIfCurrentMinLengthViolation OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Rx payload Min Length Violation frames encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfCurrentEntry 7 }
|
|
|
|
virtualIfCurrentMaxLengthViolation OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Rx payload Max Length Violation frames
|
|
encountered by a Virtual Interface in the current 15-minute interval."
|
|
::= { virtualIfCurrentEntry 8 }
|
|
|
|
virtualIfCurrentFcsError OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter is associated with the number of
|
|
Frame Check Sequence errors encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfCurrentEntry 9 }
|
|
|
|
virtualIfCurrentByteDestuffingViolation OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
Byte De-stuffing Violations encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= {virtualIfCurrentEntry 10 }
|
|
|
|
|
|
virtualIfCurrentAdressMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
Adress Mismatch encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= {virtualIfCurrentEntry 11 }
|
|
|
|
virtualIfCurrentControlMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
Control Mismatch encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= {virtualIfCurrentEntry 12 }
|
|
|
|
virtualIfCurrentActiveVC OBJECT-TYPE
|
|
SYNTAX Integer32 (1..64)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the number of active virtual containers (VCs)
|
|
of the Virtual Concatenation Group in the current 15-minute interval."
|
|
::= {virtualIfCurrentEntry 13 }
|
|
|
|
|
|
|
|
-- the Virtual Interface Interval Table
|
|
|
|
-- The Virtual Interface Interval Table
|
|
-- contains various statistics collected over a maximum
|
|
-- of the previous 24 hours of operation.
|
|
-- The past 24 hours may be broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
virtualIfIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VirtualIfIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Interface Interval table."
|
|
::= { virtualIfStatistics 2 }
|
|
|
|
virtualIfIntervalEntry OBJECT-TYPE
|
|
SYNTAX VirtualIfIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Interface Interval table."
|
|
INDEX { ifIndex, virtualIfIntervalNumber }
|
|
::= { virtualIfIntervalTable 1 }
|
|
|
|
VirtualIfIntervalEntry ::=
|
|
SEQUENCE {
|
|
virtualIfIntervalNumber Integer32,
|
|
virtualIfIntervalMinActiveVC Integer32,
|
|
virtualIfIntervalMaxActiveVC Integer32,
|
|
virtualIfIntervalRxFrames Counter64,
|
|
virtualIfIntervalTxFrames Counter64,
|
|
virtualIfIntervalRxAbortFrames PerfIntervalCount,
|
|
virtualIfIntervalTxAbortFrames PerfIntervalCount,
|
|
virtualIfIntervalMinLengthViolation PerfIntervalCount,
|
|
virtualIfIntervalMaxLengthViolation PerfIntervalCount,
|
|
virtualIfIntervalFcsError PerfIntervalCount,
|
|
virtualIfIntervalByteDestuffingViolation PerfIntervalCount,
|
|
virtualIfIntervalAdressMismatch PerfIntervalCount,
|
|
virtualIfIntervalControlMismatch PerfIntervalCount,
|
|
virtualIfIntervalBelowMinThreshold PerfIntervalCount
|
|
}
|
|
|
|
virtualIfIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, which identifies the
|
|
interval for which the set of statistics is available.
|
|
The interval identified by 1 is the most recently
|
|
completed 15 minute interval,
|
|
and the interval identified
|
|
by N is the interval immediately preceding the
|
|
one identified by N-1."
|
|
::= { virtualIfIntervalEntry 1 }
|
|
|
|
virtualIfIntervalMinActiveVC OBJECT-TYPE
|
|
SYNTAX Integer32 (1..64)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the minimum number of
|
|
active virtual containers (VCs) of the Virtual Concatenation Group, in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 2 }
|
|
|
|
virtualIfIntervalMaxActiveVC OBJECT-TYPE
|
|
SYNTAX Integer32 (1..64)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the maximum number of
|
|
active virtual containers (VCs) of the Virtual Concatenation Group, in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 3 }
|
|
|
|
virtualIfIntervalRxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
frames received from STS-3/STM-1 by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 4 }
|
|
|
|
virtualIfIntervalTxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
frames transmitted to STS-3/STM-1 by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 5 }
|
|
|
|
virtualIfIntervalRxAbortFrames OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Received Abort frames encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= {virtualIfIntervalEntry 6 }
|
|
|
|
virtualIfIntervalTxAbortFrames OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Transmitted Abort frames encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 7 }
|
|
|
|
virtualIfIntervalMinLengthViolation OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Rx payload Min Length Violation frames
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 8 }
|
|
|
|
virtualIfIntervalMaxLengthViolation OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Rx payload Max Length Violation frames
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 9 }
|
|
|
|
virtualIfIntervalFcsError OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Frame Check Sequence errors encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 10 }
|
|
|
|
virtualIfIntervalByteDestuffingViolation OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Byte De-stuffing Violations
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 11 }
|
|
|
|
|
|
virtualIfIntervalAdressMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Address Mismatch encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 12 }
|
|
|
|
virtualIfIntervalControlMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
Control mismatch encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 13 }
|
|
|
|
virtualIfIntervalBelowMinThreshold OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
seconds that number of active VCs was below minimum threshold
|
|
defined by vcGroupCnfgNoOfVCs,
|
|
encountered by Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfIntervalEntry 14 }
|
|
|
|
|
|
|
|
|
|
|
|
-- the Virtual Interface LAPS Current Table
|
|
|
|
virtualIfLAPSCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VcGroupLAPSCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Interface LAPS Current table."
|
|
::= { virtualIfStatistics 3 }
|
|
|
|
virtualIfLAPSCurrentEntry OBJECT-TYPE
|
|
SYNTAX VcGroupLAPSCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Interface
|
|
LAPS Current table."
|
|
INDEX { ifIndex }
|
|
::= { virtualIfLAPSCurrentTable 1 }
|
|
|
|
VcGroupLAPSCurrentEntry ::=
|
|
SEQUENCE {
|
|
virtualIfLAPSCurrentSapiMismatch PerfCurrentCount
|
|
}
|
|
|
|
|
|
virtualIfLAPSCurrentSapiMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received SAPI field mismatch
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfLAPSCurrentEntry 1 }
|
|
|
|
|
|
|
|
-- the Virtual Interface LAPS Interval Table
|
|
|
|
-- The Virtual Interface LAPS Interval Table
|
|
-- contains various statistics collected over a maximum
|
|
-- of the previous 24 hours of operation.
|
|
-- The past 24 hours may be broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
virtualIfLAPSIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VirtualIfLAPSIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Interface LAPS table."
|
|
::= { virtualIfStatistics 4 }
|
|
|
|
virtualIfLAPSIntervalEntry OBJECT-TYPE
|
|
SYNTAX VirtualIfLAPSIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Interface
|
|
LAPS Interval table."
|
|
INDEX { ifIndex, virtualIfIntervalNumber }
|
|
::= { virtualIfLAPSIntervalTable 1 }
|
|
|
|
VirtualIfLAPSIntervalEntry ::=
|
|
SEQUENCE {
|
|
virtualIfLAPSIntervalSapiMismatch PerfIntervalCount
|
|
}
|
|
|
|
virtualIfLAPSIntervalSapiMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received SAPI field mismatch
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfLAPSIntervalEntry 1 }
|
|
|
|
|
|
-- the Virtual Interface LAPF Current Table
|
|
|
|
virtualIfLAPFCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VirtualIfLAPFCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Interface LAPF Current table."
|
|
::= { virtualIfStatistics 5 }
|
|
|
|
virtualIfLAPFCurrentEntry OBJECT-TYPE
|
|
SYNTAX VirtualIfLAPFCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Interface
|
|
LAPF Current table."
|
|
INDEX { ifIndex }
|
|
::= { virtualIfLAPFCurrentTable 1 }
|
|
|
|
VirtualIfLAPFCurrentEntry ::=
|
|
SEQUENCE {
|
|
virtualIfLAPFCurrentNlpidMismatch PerfCurrentCount,
|
|
virtualIfLAPFCurrentOuiMismatch PerfCurrentCount,
|
|
virtualIfLAPFCurrentPidMismatch PerfCurrentCount,
|
|
virtualIfLAPFCurrentDlciMismatch PerfCurrentCount,
|
|
virtualIfLAPFCurrentMacRxFrames PerfCurrentCount,
|
|
virtualIfLAPFCurrentMacTxFrames PerfCurrentCount
|
|
}
|
|
|
|
|
|
virtualIfLAPFCurrentNlpidMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received NLPID field mismatch
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfLAPFCurrentEntry 1 }
|
|
|
|
virtualIfLAPFCurrentOuiMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received OUI field mismatch
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfLAPFCurrentEntry 2 }
|
|
|
|
|
|
virtualIfLAPFCurrentPidMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received PID field mismatch
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfLAPFCurrentEntry 3 }
|
|
|
|
|
|
virtualIfLAPFCurrentDlciMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received DLCI field mismatch
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfLAPFCurrentEntry 4 }
|
|
|
|
|
|
virtualIfLAPFCurrentMacRxFrames OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
frames received from LAN
|
|
by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfLAPFCurrentEntry 5 }
|
|
|
|
|
|
virtualIfLAPFCurrentMacTxFrames OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
frames transmitted to LAN
|
|
by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfLAPFCurrentEntry 6 }
|
|
|
|
|
|
-- the Virtual Interface LAPF Interval Table
|
|
|
|
-- The Virtual Interface LAPF Interval Table
|
|
-- contains various statistics collected over a maximum
|
|
-- of the previous 24 hours of operation.
|
|
-- The past 24 hours may be broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
virtualIfLAPFIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VirtualIfLAPFIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Interface LAPF Interval table."
|
|
::= { virtualIfStatistics 6 }
|
|
|
|
virtualIfLAPFIntervalEntry OBJECT-TYPE
|
|
SYNTAX VirtualIfLAPFIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Interface Interval table."
|
|
INDEX { ifIndex, virtualIfIntervalNumber }
|
|
::= { virtualIfLAPFIntervalTable 1 }
|
|
|
|
VirtualIfLAPFIntervalEntry ::=
|
|
SEQUENCE {
|
|
virtualIfLAPFIntervalNlpidMismatch PerfIntervalCount,
|
|
virtualIfLAPFIntervalOuiMismatch PerfIntervalCount,
|
|
virtualIfLAPFIntervalPidMismatch PerfIntervalCount,
|
|
virtualIfLAPFIntervalDlciMismatch PerfIntervalCount,
|
|
virtualIfLAPFIntervalMacRxFrames PerfIntervalCount,
|
|
virtualIfLAPFIntervalMacTxFrames PerfIntervalCount
|
|
}
|
|
|
|
|
|
virtualIfLAPFIntervalNlpidMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received NLPID field mismatch
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfLAPFIntervalEntry 1 }
|
|
|
|
|
|
virtualIfLAPFIntervalOuiMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received OUI field mismatch
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfLAPFIntervalEntry 2 }
|
|
|
|
|
|
|
|
virtualIfLAPFIntervalPidMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received PID field mismatch
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfLAPFIntervalEntry 3 }
|
|
|
|
|
|
virtualIfLAPFIntervalDlciMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received DLCI field mismatch
|
|
by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfLAPFIntervalEntry 4 }
|
|
|
|
virtualIfLAPFIntervalMacRxFrames OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
frames received from LAN
|
|
by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfLAPFIntervalEntry 5 }
|
|
|
|
virtualIfLAPFIntervalMacTxFrames OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
frames transmitted to LAN
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfLAPFIntervalEntry 6 }
|
|
|
|
|
|
-- the Virtual Interface GFP Current Table
|
|
|
|
virtualIfGFPCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VirtualIfGFPCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Interface GFP Current table."
|
|
::= { virtualIfStatistics 7 }
|
|
|
|
virtualIfGFPCurrentEntry OBJECT-TYPE
|
|
SYNTAX VirtualIfGFPCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Interface
|
|
GFP Current table."
|
|
INDEX { ifIndex }
|
|
::= { virtualIfGFPCurrentTable 1 }
|
|
|
|
VirtualIfGFPCurrentEntry ::=
|
|
SEQUENCE {
|
|
virtualIfGFPCurrentIdleFrameError PerfCurrentCount,
|
|
virtualIfGFPCurrentCHecSbError PerfCurrentCount,
|
|
virtualIfGFPCurrentPtiMismatch PerfCurrentCount,
|
|
virtualIfGFPCurrentExiMismatch PerfCurrentCount,
|
|
virtualIfGFPCurrentUpiMismatch PerfCurrentCount,
|
|
virtualIfGFPCurrentTHecSbError PerfCurrentCount,
|
|
virtualIfGFPCurrentTHecMbError PerfCurrentCount,
|
|
virtualIfGFPCurrentCidMismatch PerfCurrentCount,
|
|
virtualIfGFPCurrentEHecSbError PerfCurrentCount,
|
|
virtualIfGFPCurrentEHecMbError PerfCurrentCount
|
|
}
|
|
|
|
virtualIfGFPCurrentIdleFrameError OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP IDLE frames that are
|
|
detected to be in error,
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 1}
|
|
|
|
virtualIfGFPCurrentCHecSbError OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected to have
|
|
single-bit errors in the Core
|
|
header (i.e. cHEC field) only,
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 2 }
|
|
|
|
virtualIfGFPCurrentPtiMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
rreceived GFP frames that are detected with
|
|
a mismatch on the PTI field
|
|
(i.e. value of PTI is not equal to
|
|
Client Data or Management frame),
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 3 }
|
|
|
|
|
|
virtualIfGFPCurrentExiMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected with
|
|
a mismatch on the EXI field
|
|
(i.e. value of EXI is not equal
|
|
to NULL or LINEAR modes),
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 4 }
|
|
|
|
|
|
virtualIfGFPCurrentUpiMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected with a
|
|
mismatch on the UPI field
|
|
(i.e. value of EXI is not equal to 00000001),
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 5 }
|
|
|
|
|
|
virtualIfGFPCurrentTHecSbError OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected
|
|
to only have single-bit errors in the Type header
|
|
(i.e. tHEC field),
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 6 }
|
|
|
|
|
|
virtualIfGFPCurrentTHecMbError OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected to
|
|
only have multi-bit errors in the
|
|
Type header (i.e. tHEC field),
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 7 }
|
|
|
|
virtualIfGFPCurrentCidMismatch OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected to have a
|
|
mismatch/unsupported value in the CID field only,
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 8 }
|
|
|
|
virtualIfGFPCurrentEHecSbError OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected
|
|
to only have single-bit errors
|
|
in the Extension header (i.e. eHEC field),
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 9 }
|
|
|
|
virtualIfGFPCurrentEHecMbError OBJECT-TYPE
|
|
SYNTAX PerfCurrentCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected to only
|
|
have single-bit errors in the
|
|
Extension header (i.e. eHEC field),
|
|
encountered by a Virtual Interface
|
|
in the current 15-minute interval."
|
|
::= { virtualIfGFPCurrentEntry 10 }
|
|
|
|
|
|
-- the Virtual Interface GFP Interval Table
|
|
|
|
-- The Virtual Interface GFP Interval Table
|
|
-- contains various statistics collected over a maximum
|
|
-- of the previous 24 hours of operation.
|
|
-- The past 24 hours may be broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
virtualIfGFPIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VirtualIfGFPIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Interface GFP Interval table."
|
|
::= { virtualIfStatistics 8 }
|
|
|
|
virtualIfGFPIntervalEntry OBJECT-TYPE
|
|
SYNTAX VirtualIfGFPIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Interface
|
|
GFP Interval table."
|
|
INDEX { ifIndex, virtualIfIntervalNumber }
|
|
::= { virtualIfGFPIntervalTable 1 }
|
|
|
|
VirtualIfGFPIntervalEntry ::=
|
|
SEQUENCE {
|
|
virtualIfGFPIntervalIdleFrameError PerfIntervalCount,
|
|
virtualIfGFPIntervalCHecSbError PerfIntervalCount,
|
|
virtualIfGFPIntervalPtiMismatch PerfIntervalCount,
|
|
virtualIfGFPIntervalExiMismatch PerfIntervalCount,
|
|
virtualIfGFPIntervalUpiMismatch PerfIntervalCount,
|
|
virtualIfGFPIntervalTHecSbError PerfIntervalCount,
|
|
virtualIfGFPIntervalTHecMbError PerfIntervalCount,
|
|
virtualIfGFPIntervalCidMismatch PerfIntervalCount,
|
|
virtualIfGFPIntervalEHecSbError PerfIntervalCount,
|
|
virtualIfGFPIntervalEHecMbError PerfIntervalCount
|
|
}
|
|
|
|
virtualIfGFPIntervalIdleFrameError OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP IDLE frames that are detected to be in error,
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 1 }
|
|
|
|
virtualIfGFPIntervalCHecSbError OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected to have
|
|
single-bit errors in the Core header (i.e. cHEC field) only,
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 2 }
|
|
|
|
virtualIfGFPIntervalPtiMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
rreceived GFP frames that are detected with
|
|
a mismatch on the PTI field (i.e. value of PTI
|
|
is not equal to Client Data or Management frame),
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 3 }
|
|
|
|
virtualIfGFPIntervalExiMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected with
|
|
a mismatch on the EXI field (i.e. value of EXI is not
|
|
equal to NULL or LINEAR modes),
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 4 }
|
|
|
|
virtualIfGFPIntervalUpiMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected with a
|
|
mismatch on the UPI field (i.e. value of EXI
|
|
is not equal to 00000001),
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 5 }
|
|
|
|
virtualIfGFPIntervalTHecSbError OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected to only have
|
|
single-bit errors in the Type header (i.e. tHEC field),
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 6 }
|
|
|
|
virtualIfGFPIntervalTHecMbError OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated withthe number of
|
|
received GFP frames that are detected to only have
|
|
multi-bit errors in the Type header (i.e. tHEC field),
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 7 }
|
|
|
|
virtualIfGFPIntervalCidMismatch OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected to have a
|
|
mismatch/unsupported value in the CID field only,
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 8 }
|
|
|
|
virtualIfGFPIntervalEHecSbError OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the number of
|
|
received GFP frames that are detected
|
|
to only have single-bit errors
|
|
in the Extension header (i.e. eHEC field),
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 9 }
|
|
|
|
virtualIfGFPIntervalEHecMbError OBJECT-TYPE
|
|
SYNTAX PerfIntervalCount
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is associated with the the number of
|
|
received GFP frames that are detected to only have
|
|
multi-bit errors in the Extension header (i.e. eHEC field),
|
|
encountered by a Virtual Interface in a
|
|
particular 15-minute interval in the past 24 hours."
|
|
::= { virtualIfGFPIntervalEntry 10 }
|
|
|
|
|
|
|
|
prtSonetConfig OBJECT IDENTIFIER ::= {sonetInterface 2}
|
|
|
|
prtSonetGen OBJECT IDENTIFIER ::= {prtSonetConfig 1}
|
|
|
|
prtSonetGenTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSonetGenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sonet/SDH general port configuration table."
|
|
::= { prtSonetGen 1}
|
|
|
|
prtSonetGenEntry OBJECT-TYPE
|
|
SYNTAX PrtSonetGenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the Sonet/SDH general port configuration table."
|
|
INDEX { prtSonetGenCnfgIdx, prtSonetGenIdx }
|
|
::= { prtSonetGenTable 1}
|
|
|
|
PrtSonetGenEntry ::=
|
|
SEQUENCE {
|
|
prtSonetGenCnfgIdx
|
|
Integer32,
|
|
prtSonetGenIdx
|
|
Integer32,
|
|
prtSonetGenSdThreshold
|
|
INTEGER,
|
|
prtSonetGenEedThreshold
|
|
INTEGER,
|
|
prtSonetGenBerEnable
|
|
INTEGER
|
|
|
|
}
|
|
|
|
prtSonetGenCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config.
|
|
For products that support several configurations, Set can be performed
|
|
only to the Temporary Config (=255). "
|
|
::= { prtSonetGenEntry 1}
|
|
|
|
prtSonetGenIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique port or interface number.
|
|
For numbering, see product's spec.
|
|
For some products, the numbering can equal ifIndex."
|
|
::= { prtSonetGenEntry 2}
|
|
|
|
prtSonetGenSdThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
n3 (3),
|
|
n4 (4),
|
|
n5 (5),
|
|
n6 (6),
|
|
n7 (7),
|
|
n8 (8),
|
|
n9 (9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SD=Signal Degraded Threshold. Units: [10E-].
|
|
The threshold is 10E-x relative to the frequency of the data flow.
|
|
x=3, 4, 5, 6, 7, 8, 9.
|
|
n3= 10E-3
|
|
n4= 10E-4
|
|
n5= 10E-5
|
|
n6= 10E-6
|
|
n7= 10E-7
|
|
n8= 10E-8
|
|
n9= 10E-9 ."
|
|
::= { prtSonetGenEntry 3 }
|
|
|
|
prtSonetGenEedThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
n3 (3),
|
|
n4 (4),
|
|
n5 (5),
|
|
n6 (6),
|
|
n7 (7),
|
|
n8 (8),
|
|
n9 (9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"EED=Excessive Error Defect Threshold. Units: [10E-].
|
|
The threshold is 10E-x relative to the frequency of the data flow.
|
|
x=3, 4, 5, 6, 7, 8, 9.
|
|
n3= 10E-3
|
|
n4= 10E-4
|
|
n5= 10E-5
|
|
n6= 10E-6
|
|
n7= 10E-7
|
|
n8= 10E-8
|
|
n9= 10E-9 ."
|
|
::= { prtSonetGenEntry 4 }
|
|
|
|
prtSonetGenBerEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the activation of the Line Ber (Bit Error Rate), means whether
|
|
SD and EED threshold parameters will be enabled."
|
|
::= { prtSonetGenEntry 5 }
|
|
|
|
|
|
|
|
|
|
--STM-1 ports
|
|
|
|
prtSonetStm1 OBJECT IDENTIFIER ::= {prtSonetConfig 2}
|
|
|
|
|
|
prtSonetStm1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSonetStm1Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sonet/SDH STM-1 port configuration table."
|
|
::= { prtSonetStm1 1}
|
|
|
|
prtSonetStm1Entry OBJECT-TYPE
|
|
SYNTAX PrtSonetStm1Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the Sonet/SDH STM-1 port configuration table."
|
|
INDEX { prtSonetStm1CnfgIdx, prtSonetStm1Idx }
|
|
::= { prtSonetStm1Table 1}
|
|
|
|
PrtSonetStm1Entry ::=
|
|
SEQUENCE {
|
|
prtSonetStm1CnfgIdx
|
|
Integer32,
|
|
prtSonetStm1Idx
|
|
Integer32,
|
|
prtSonetStm1ClockSrc
|
|
INTEGER,
|
|
prtSonetStm1DccMode
|
|
INTEGER,
|
|
prtSonetStm1RoutingProt
|
|
INTEGER,
|
|
prtSonetStm1MngProt
|
|
INTEGER,
|
|
prtSonetStm1OperationalMode
|
|
INTEGER,
|
|
prtSonetStm1VoiceChannel
|
|
INTEGER
|
|
}
|
|
|
|
prtSonetStm1CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config.
|
|
For products that support several configurations, Set can be performed
|
|
only to the Temporary Config (=255). "
|
|
::= { prtSonetStm1Entry 1}
|
|
|
|
prtSonetStm1Idx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique port or interface number.
|
|
For numbering, see product's spec.
|
|
For some products, the numbering can equal ifIndex."
|
|
::= { prtSonetStm1Entry 2}
|
|
|
|
prtSonetStm1ClockSrc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
internal (2),
|
|
lbt (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock Source of the STM-1 port.
|
|
lbt = Loop Back Timing."
|
|
::= { prtSonetStm1Entry 3 }
|
|
|
|
prtSonetStm1DccMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
none (2),
|
|
d1ToD3 (3),
|
|
d4ToD12 (4),
|
|
d1 (5),
|
|
d2 (6),
|
|
d3 (7),
|
|
d4 (8),
|
|
d5 (9),
|
|
d6 (10),
|
|
d7 (11),
|
|
d8 (12),
|
|
d9 (13),
|
|
d10 (14),
|
|
d11 (15),
|
|
d12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DCC Mode. DCC=Data Communication Channel.
|
|
d1ToD3 = D1-D3 bytes are used (RS=Regeneration Section).
|
|
d4ToD12= D4-D12 bytes are used (MS=Multiplexing Section).
|
|
d1.... d12 enable user to select single DCC byte "
|
|
::= { prtSonetStm1Entry 4 }
|
|
|
|
prtSonetStm1RoutingProt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
proprietary (3),
|
|
rip2 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Routing Protocol."
|
|
::= { prtSonetStm1Entry 5 }
|
|
|
|
prtSonetStm1MngProt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
-- none (2)
|
|
proprietary (3),
|
|
-- rip2 (4)
|
|
ppp (5),
|
|
frameRelay (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management Protocol over DCC: Proprietary, PPP or Frame Relay."
|
|
::= { prtSonetStm1Entry 6 }
|
|
|
|
prtSonetStm1OperationalMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
terminal (2),
|
|
linear (3),
|
|
linearProtection (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operational Mode.
|
|
linear - cannot be selected when there is Redundancy between the
|
|
STM-1 ports."
|
|
::= { prtSonetStm1Entry 7 }
|
|
|
|
prtSonetStm1VoiceChannel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
e1Byte (3),
|
|
e2Byte (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter enable user to select whether
|
|
voice channel will be transferred using E1 byte, E2 Byte, or not at all."
|
|
::= { prtSonetStm1Entry 8 }
|
|
|
|
|
|
--SONET/SDH VC-3, VC-4 and VC-12 ports parameters
|
|
|
|
prtSonetVc OBJECT IDENTIFIER ::= {prtSonetConfig 3}
|
|
|
|
|
|
prtSonetVcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSonetVcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sonet/SDH VC port configuration table."
|
|
::= { prtSonetVc 1}
|
|
|
|
prtSonetVcEntry OBJECT-TYPE
|
|
SYNTAX PrtSonetVcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the Sonet/SDH VC port configuration table."
|
|
INDEX { prtSonetVcCnfgIdx, prtSonetVcIdx }
|
|
::= { prtSonetVcTable 1}
|
|
|
|
PrtSonetVcEntry ::=
|
|
SEQUENCE {
|
|
prtSonetVcCnfgIdx
|
|
Integer32,
|
|
prtSonetVcIdx
|
|
Integer32,
|
|
prtSonetVcJTxPathTraceEnable
|
|
INTEGER,
|
|
prtSonetVcJRxPathTraceEnable
|
|
INTEGER,
|
|
prtSonetVcJPathTrace
|
|
DisplayString,
|
|
prtSonetVcConnect
|
|
INTEGER
|
|
}
|
|
|
|
prtSonetVcCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config.
|
|
For products that support several configurations, Set can be performed
|
|
only to the Temporary Config (=255). "
|
|
::= { prtSonetVcEntry 1}
|
|
|
|
prtSonetVcIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique port or interface number.
|
|
For numbering, see product's spec.
|
|
For some products, the numbering can equal ifIndex."
|
|
::= { prtSonetVcEntry 2}
|
|
|
|
prtSonetVcJTxPathTraceEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable Transmitting Jy Path Trace. y=1, 2:
|
|
J1 - for VC-4 layer
|
|
J2 - for VC-12 layer."
|
|
::= { prtSonetVcEntry 3 }
|
|
|
|
prtSonetVcJRxPathTraceEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable checking Jy Path Trace. y=1, 2:
|
|
J1 - for VC-4 layer
|
|
J2 - for VC-12 layer."
|
|
::= { prtSonetVcEntry 4 }
|
|
|
|
prtSonetVcJPathTrace OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Jy Path Trace. y=1, 2:
|
|
J1 - for VC-4 layer
|
|
J2 - for VC-12 layer.
|
|
This object is applicable only if one of the previous 2 objects is 'enable'."
|
|
::= { prtSonetVcEntry 5 }
|
|
|
|
prtSonetVcConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Connect VCn (n - 11,12,2,3,4) port (yes/no)."
|
|
::= { prtSonetVcEntry 6 }
|
|
|
|
|
|
|
|
--TU-12 (within VC-4) Connect Table
|
|
|
|
prtSonetTuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSonetTuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table's Objects is valid only
|
|
for the TmpCnfg entry (Scratch)."
|
|
::= { prtSonetVc 2}
|
|
|
|
prtSonetTuEntry OBJECT-TYPE
|
|
SYNTAX PrtSonetTuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtSonetTuCnfgIdx, prtSonetTuPrtIdx, prtSonetTuIdx, prtSonetTuConPrtIdx }
|
|
::= { prtSonetTuTable 1}
|
|
|
|
PrtSonetTuEntry ::=
|
|
SEQUENCE {
|
|
prtSonetTuCnfgIdx Integer32,
|
|
prtSonetTuPrtIdx Integer32,
|
|
prtSonetTuIdx Integer32,
|
|
prtSonetTuConPrtIdx Integer32,
|
|
prtSonetTuType INTEGER,
|
|
prtSonetTuMode INTEGER,
|
|
prtSonetTuRowStatus RowStatus
|
|
}
|
|
|
|
prtSonetTuCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config.
|
|
For products that support several configurations, Set can be performed
|
|
only to the Temporary Config (=255). "
|
|
::= { prtSonetTuEntry 1}
|
|
|
|
prtSonetTuPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique port or interface number.
|
|
For port numbering, see product's spec.
|
|
For some products, the numbering can equal ifIndex."
|
|
::= { prtSonetTuEntry 2}
|
|
|
|
prtSonetTuIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique TU (Tributary Unit) within VC-4.
|
|
The valid TUs are 1..63."
|
|
::= { prtSonetTuEntry 3}
|
|
|
|
prtSonetTuConPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the connected port, when prtSonetTuType=connect.
|
|
For port numbering, see product's spec.
|
|
For some products, the numbering can equal ifIndex.
|
|
notApplicable - will be indicated as 100."
|
|
::= {prtSonetTuEntry 4}
|
|
|
|
prtSonetTuType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
connect (2),
|
|
bypass (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of TU (Tributary Unit).
|
|
connect - connected to one of the E1 ports.
|
|
bypass - bypassed to the other VC4 port.
|
|
TUs that are not connected or bypassed, will not exist in this table."
|
|
::= { prtSonetTuEntry 5}
|
|
|
|
prtSonetTuMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
addAndDrop (2),
|
|
add (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TU Mode of connection.
|
|
addAndDrop - Add & Drop
|
|
add - Add (TU receives from the E1 ports)."
|
|
::= { prtSonetTuEntry 6}
|
|
|
|
prtSonetTuRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= { prtSonetTuEntry 7}
|
|
|
|
|
|
-- SDH Cross Connect Table
|
|
-- May be used also for SONET
|
|
|
|
prtSonetXConnect OBJECT IDENTIFIER ::= {sonetInterface 3}
|
|
|
|
prtSonetXConnectTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSonetXConnectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table's Objects is valid only
|
|
for the TmpCnfg entry (Scratch)."
|
|
::= { prtSonetXConnect 1}
|
|
|
|
prtSonetXConnectEntry OBJECT-TYPE
|
|
SYNTAX PrtSonetXConnectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {
|
|
prtSonetXConnectCnfgIdx,
|
|
prtSonetXConnectPrtIdx,
|
|
prtSonetXConnectConPrtIdx,
|
|
prtSonetXConnectAUGIdx,
|
|
prtSonetXConnectTUG3Idx,
|
|
prtSonetXConnectTUG2Idx,
|
|
prtSonetXConnectTUnIdx
|
|
}
|
|
::= { prtSonetXConnectTable 1}
|
|
|
|
PrtSonetXConnectEntry ::=
|
|
SEQUENCE {
|
|
prtSonetXConnectCnfgIdx Integer32,
|
|
prtSonetXConnectPrtIdx Integer32,
|
|
prtSonetXConnectConPrtIdx Integer32,
|
|
prtSonetXConnectAUGIdx Integer32,
|
|
prtSonetXConnectTUG3Idx Integer32,
|
|
prtSonetXConnectTUG2Idx Integer32,
|
|
prtSonetXConnectTUnIdx Integer32,
|
|
prtSonetXConnectRowStatus RowStatus,
|
|
prtSonetXConnectDirection INTEGER,
|
|
prtSonetXConnectTuNumber INTEGER
|
|
}
|
|
|
|
prtSonetXConnectCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config.
|
|
For products that support several configurations, Set can be performed
|
|
only to the Temporary Config (=255). "
|
|
::= { prtSonetXConnectEntry 1}
|
|
|
|
prtSonetXConnectPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique port or interface number.
|
|
For port numbering, see product's spec.
|
|
For some products, the numbering can equal ifIndex."
|
|
::= { prtSonetXConnectEntry 2}
|
|
|
|
prtSonetXConnectConPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the connected port.
|
|
For port numbering, see product's spec.
|
|
For some products, the numbering can equal ifIndex.
|
|
notApplicable - will be indicated as 255."
|
|
::= {prtSonetXConnectEntry 3}
|
|
|
|
|
|
prtSonetXConnectAUGIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates an AUG (Administrative Unit Group) within STM-N.
|
|
The valid AUGs values are:
|
|
1 for STM-1
|
|
1...4 for STM-4,
|
|
1..16 for STM-16 and
|
|
1..64 for STM-64 (STM-64)
|
|
255 designates NA."
|
|
::= { prtSonetXConnectEntry 4}
|
|
|
|
prtSonetXConnectTUG3Idx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a TUG-3 (Tributary Unit Group 3) within VC-4.
|
|
The valid TUG3s are values are 1..3. and 255 which designates NA "
|
|
::= { prtSonetXConnectEntry 5}
|
|
|
|
prtSonetXConnectTUG2Idx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a TUG2 (Tributary Unit Group 2 ) within VC-3.
|
|
The valid TUG2's values are 1..7 and 255 which designates NA "
|
|
::= { prtSonetXConnectEntry 6}
|
|
|
|
prtSonetXConnectTUnIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a TUn within TUG-2 or TUG-3
|
|
(Tributary Unit n, where n is 2, 12 or 11 within TUG-2,
|
|
or 3 within TUG-3)
|
|
valid values are
|
|
1 for TU-2
|
|
1 for TU-3
|
|
1..4 for TU-11
|
|
1..3 for TU-12
|
|
255 designates NA"
|
|
::= { prtSonetXConnectEntry 7}
|
|
|
|
|
|
prtSonetXConnectRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= { prtSonetXConnectEntry 8}
|
|
|
|
|
|
prtSonetXConnectDirection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
rx (2),
|
|
tx (3),
|
|
both (4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TU direction of connection.
|
|
rx=Drop
|
|
tx=Add
|
|
both = Add & Drop "
|
|
::= { prtSonetXConnectEntry 9}
|
|
|
|
prtSonetXConnectTuNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
tu2 (2),
|
|
tu3 (3),
|
|
tu11 (4),
|
|
tu12 (5)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates which TU is used in prtSonetXConnectTUnIdx "
|
|
::= { prtSonetXConnectEntry 10}
|
|
|
|
|
|
prtVcGroupCnfg OBJECT IDENTIFIER ::= {prtSonetConfig 4}
|
|
|
|
vcGroupCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VcGroupCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Concatenation Group configuration table."
|
|
::= { prtVcGroupCnfg 1 }
|
|
|
|
vcGroupCnfgEntry OBJECT-TYPE
|
|
SYNTAX VcGroupCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Concatenation Group
|
|
configuration table."
|
|
INDEX { vcGroupCnfgIdx,vcGroupCnfgNumber}
|
|
::= { vcGroupCnfgTable 1 }
|
|
|
|
VcGroupCnfgEntry ::=
|
|
SEQUENCE {
|
|
vcGroupCnfgIdx Integer32,
|
|
vcGroupCnfgNumber Integer32,
|
|
vcGroupCnfgRowStatus RowStatus,
|
|
vcGroupCnfgVcType INTEGER,
|
|
vcGroupCnfgNoOfVCs Integer32,
|
|
vcGroupCnfgLCAS INTEGER,
|
|
vcGroupCnfgEncapsulation INTEGER,
|
|
vcGroupCnfgGroupIfIndex InterfaceIndex,
|
|
vcGroupCnfgRip2 INTEGER,
|
|
vcGroupCnfgGfpChId Integer32
|
|
}
|
|
|
|
vcGroupCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config.
|
|
For products that support several configurations, Set can be performed
|
|
only to the Temporary Config (=255). "
|
|
::= { vcGroupCnfgEntry 1}
|
|
|
|
|
|
vcGroupCnfgNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Virtual Concatenation Group Number.
|
|
For FCD=155 up to four groups are defined
|
|
valid values are 1..4"
|
|
::= { vcGroupCnfgEntry 2}
|
|
|
|
vcGroupCnfgRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= { vcGroupCnfgEntry 3}
|
|
|
|
vcGroupCnfgVcType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
vc12 (2), --SDH
|
|
vc3 (3), --SDH
|
|
vc4 (4), --SDH
|
|
vt1dot5 (5), --SONET VT1.5
|
|
sts1 (6) --SONET STS-1 /SPE
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User may select type of SDH Virtual Containers (VC)
|
|
(SONET Virtual Tributaries VT ) to be concatenated
|
|
in this Virtual Concatenation Group.
|
|
For SDH, values 2,3,4 are valid.
|
|
For SONET, values 5 and 6 are valid."
|
|
::= { vcGroupCnfgEntry 4}
|
|
|
|
vcGroupCnfgNoOfVCs OBJECT-TYPE
|
|
SYNTAX Integer32 (0..84)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User may select number of Virtual Containers (VC)
|
|
(SONET Virtual Tributaries VT ) to be concatenated
|
|
in this Virtual Concatenation Group.
|
|
Valid range for this number depends on
|
|
type VC selected by vcGroupCnfgVCType
|
|
For SDH, up to 63 VC12, or
|
|
up to 3 VC3, or
|
|
1 VC4 are valid
|
|
For SONET, up to 84 VT1.5 without LCAS,
|
|
or 64 VT1.5 under LCAS control.
|
|
or up tp 3 STS-1/SPE, or
|
|
1 STS-3"
|
|
::= { vcGroupCnfgEntry 5}
|
|
|
|
vcGroupCnfgLCAS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
lcasNotActive (2),
|
|
lcasActive (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls Link Capacity Adjustment
|
|
Scheme (LCAS) activation."
|
|
::= { vcGroupCnfgEntry 6}
|
|
|
|
vcGroupCnfgEncapsulation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
laps (2), -- Link access protocol S
|
|
lapf (3), -- Link access protocol F (Frame relay)
|
|
gfp (4) -- Generic Framing Procedure
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables user to select encapsulation method."
|
|
::= { vcGroupCnfgEntry 7}
|
|
|
|
|
|
vcGroupCnfgGroupIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex assigend to this group."
|
|
::= { vcGroupCnfgEntry 8}
|
|
|
|
vcGroupCnfgRip2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls RIP 2.
|
|
User may select to send RIP 2 message over
|
|
selected group or not"
|
|
::= { vcGroupCnfgEntry 9}
|
|
|
|
|
|
vcGroupCnfgGfpChId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generic Framing Procedure (GFP) Channel ID,
|
|
Valid only when vcGroupCnfgEncapsulation = gfp (4)
|
|
Valid values are 0x00 - oxFF (hex) "
|
|
::= { vcGroupCnfgEntry 10}
|
|
|
|
|
|
|
|
vcgGfpMuxCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VcgGfpMuxCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Concatenation Group GFP Mux configuration table."
|
|
::= { prtVcGroupCnfg 2 }
|
|
|
|
-- This table defines multiplexing scheme for GFP mux of
|
|
-- Virtual Concatenation Groups:
|
|
-- Primary group, Secondary group/s and bandwidth allocation
|
|
-- to each group.
|
|
|
|
vcgGfpMuxCnfgEntry OBJECT-TYPE
|
|
SYNTAX VcgGfpMuxCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Virtual Concatenation Group GFP Mux
|
|
configuration table."
|
|
INDEX { vcgGfpMuxCnfgIdx,vcgGfpMuxCnfgMuxNumber}
|
|
::= { vcgGfpMuxCnfgTable 1 }
|
|
|
|
VcgGfpMuxCnfgEntry ::=
|
|
SEQUENCE {
|
|
vcgGfpMuxCnfgIdx Integer32,
|
|
vcgGfpMuxCnfgMuxNumber Integer32,
|
|
vcgGfpMuxCnfgRowStatus RowStatus,
|
|
vcgGfpMuxCnfgMuxName SnmpAdminString,
|
|
vcgGfpMuxCnfgPrimeGroup Integer32,
|
|
vcgGfpMuxCnfgGrpBwAlloc OCTET STRING
|
|
}
|
|
|
|
vcgGfpMuxCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Index of the configuration being accessed.
|
|
Index of 255 relates to the Temporary (Scratch) coninguration.
|
|
For products that support several configurations, Set can be performed
|
|
only to the Temporary Config (=255). "
|
|
::= { vcgGfpMuxCnfgEntry 1}
|
|
|
|
vcgGfpMuxCnfgMuxNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Virtual Concatenation Group GFP Mux Number.
|
|
For FCD=155 up to 2 GFP muxes can be created."
|
|
::= { vcgGfpMuxCnfgEntry 2}
|
|
|
|
vcgGfpMuxCnfgRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= { vcgGfpMuxCnfgEntry 3}
|
|
|
|
vcgGfpMuxCnfgMuxName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Virtual Concatenation Group, GFP Mux name."
|
|
::= { vcgGfpMuxCnfgEntry 4}
|
|
|
|
|
|
vcgGfpMuxCnfgPrimeGroup OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of Virtual Concatenation Group used as
|
|
Primary for the GFP mux created
|
|
for FCD 155 four Virtual Concatenation Group are defined:
|
|
1 -> Virtual Concatenation Group 1
|
|
2 -> Virtual Concatenation Group 2
|
|
3 -> Virtual Concatenation Group 3
|
|
4 -> Virtual Concatenation Group 4"
|
|
::= { vcgGfpMuxCnfgEntry 5}
|
|
|
|
|
|
vcgGfpMuxCnfgGrpBwAlloc OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the allocated bandwidth (BW) to each
|
|
Virtual Concatenation Group (VCG).
|
|
Each nibble indicates BW percentage, in 12.5% steps,
|
|
assigned to a group.
|
|
|
|
For FCD-155, there are 4 VCGs.
|
|
One VCG is identified as primary group by vcGfpMuxConfPrimeGroup.
|
|
Other VCGs may be secondaries.
|
|
VCG with allocated BW value of zero does not belong to the GFPmux
|
|
defined by GFP Mux number.
|
|
________________________________________
|
|
| Octet 0 | Octet 1 |
|
|
|Nibble 4 Nibble 3| Nibble 2| Nibble 1|
|
|
MSB | 7 6 5 4 | 3 2 1 0 | 7 6 5 4 | 3 2 1 0 | LSB
|
|
VCG1 VCG2 VCG 3 VCG4
|
|
Nibble value - BW Percentage
|
|
(0...7) (0 ...87.5%)
|
|
1 0001 12.5 %
|
|
2 0010 25%
|
|
3 0011 37.5
|
|
.....
|
|
7 0111 87.5%
|
|
|
|
at least one nibble must be greater that zero.
|
|
Sum of alloacted BW must be 100%.
|
|
Primary VCG BW must be greater than zero."
|
|
::= { vcgGfpMuxCnfgEntry 6}
|
|
|
|
|
|
-- END--
|
|
-- file :v:\doc\rdv\mib\ver495\atm\NtePrtCo.txt
|
|
--
|
|
-- *************************
|
|
-- file : NtePrtConfg.txt
|
|
--
|
|
--Version: 1.0
|
|
--Date: 12.11.97
|
|
--By: Ilana Schvetz
|
|
--File: v:\doc\rdv\mib\ver495\atm\NtePrtConfg.txt
|
|
|
|
--Last Update: 15-Feb-04 by Yig'al Hachmon (back to original 495)
|
|
-- Copyright 1997 RAD Data Communications, Ltd.
|
|
-- All Rights Reserved.
|
|
|
|
atmNte OBJECT IDENTIFIER ::= { radAtm 3 }
|
|
atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 }
|
|
atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 }
|
|
|
|
atmNteEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for RAD ATM products."
|
|
::= { atmNte 0 }
|
|
|
|
atmNteConfIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteConfIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Physical interface configuration table."
|
|
::= { atmNtePrtConfig 1 }
|
|
|
|
atmNteConfIfEntry OBJECT-TYPE
|
|
SYNTAX AtmNteConfIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Physical interface configuration table.
|
|
The ifIndex is of the lowest physical layer."
|
|
INDEX { ifIndex}
|
|
::= { atmNteConfIfTable 1 }
|
|
|
|
AtmNteConfIfEntry ::=
|
|
SEQUENCE {
|
|
atmConfIfTransmitClk
|
|
INTEGER,
|
|
atmConfIfLoopback
|
|
INTEGER,
|
|
atmConfIfFrameType
|
|
INTEGER,
|
|
atmConfIfCardType
|
|
INTEGER,
|
|
atmConfAtmIfVpiVciLimit
|
|
INTEGER,
|
|
atmConfIfHwFeatures
|
|
INTEGER,
|
|
atmConfIfOutputRate
|
|
Integer32,
|
|
atmConfIfInputRate
|
|
Integer32,
|
|
atmConfAlarmForwarding
|
|
INTEGER,
|
|
atmConfIfAllocatedBw
|
|
Integer32,
|
|
atmConfIfLowerVpi
|
|
Integer32,
|
|
atmConfIfOamMode
|
|
INTEGER
|
|
}
|
|
|
|
atmConfIfTransmitClk OBJECT-TYPE
|
|
SYNTAX INTEGER { internal(2), external(3), loopback(4), adaptive(5) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit clock of the port."
|
|
::= { atmNteConfIfEntry 1 }
|
|
|
|
atmConfIfLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER { internal(2), external(3), disable(4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface Loopback."
|
|
::= { atmNteConfIfEntry 2 }
|
|
|
|
atmConfIfFrameType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
sonet (2),
|
|
sdh (3),
|
|
direct (4),
|
|
plcpInternal (5),
|
|
plcpExternal (6),
|
|
e3 (7),
|
|
ethCrcTrans (8),
|
|
ethCrcNotTrans (9),
|
|
directNoScrmbling (10),
|
|
plcpInternalNoScrmbling (11),
|
|
plcpExternalNoScrmbling (12)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The frame type. Valid values for a 155M interface:
|
|
sonet(2), sdh(3). Valid values for a T3 interface:
|
|
direct(4), plcpInternal(5), plcpExternal(6),
|
|
directNoScrmbling(10), plcpInternalNoScrmbling(11),
|
|
plcpExternalNoScrmbling(12). Valid values for Ethernet
|
|
interface: ethCrcTrans (8), ethCrcNotTrans(9).
|
|
(DS1 interfaces frame type is specified in the DSX1 mib)."
|
|
::= { atmNteConfIfEntry 3 }
|
|
|
|
atmConfIfCardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
sc13m-155(2),
|
|
st13s-155(3),
|
|
st13l-155(4),
|
|
utp-155(5),
|
|
cx-bnc-155(6),
|
|
e3(7),
|
|
t3(8),
|
|
e1(9),
|
|
e1-ltu(10),
|
|
fc13l-155(11),
|
|
fc13lh-155(12),
|
|
fc15lh-155(13),
|
|
fc13l-e3(14),
|
|
fc13lh-e3(15),
|
|
fc15lh-e3(16),
|
|
fc13l-t3(17),
|
|
fc13lh-t3(18),
|
|
fc15lh-t3(19)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The card type."
|
|
::= { atmNteConfIfEntry 4 }
|
|
|
|
atmConfAtmIfVpiVciLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bits15(2),
|
|
bits17(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The limit on the sum of the VPI+VCI bits for this interface."
|
|
::= { atmNteConfIfEntry 5 }
|
|
|
|
atmConfIfHwFeatures OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HW features command."
|
|
::= { atmNteConfIfEntry 6 }
|
|
|
|
atmConfIfOutputRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates the output rate in cells/sec, which is
|
|
supported per port. Successfully setting this parameter
|
|
is dependent on all other ports values calculations,
|
|
which are described in the NMS SRS."
|
|
::= { atmNteConfIfEntry 7 }
|
|
|
|
atmConfIfInputRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates the input rate in cells/sec, which is
|
|
supported per port. Successfully setting this parameter
|
|
is dependent on all other ports values calculations,
|
|
which are described in the NMS SRS."
|
|
::= { atmNteConfIfEntry 8 }
|
|
|
|
atmConfAlarmForwarding OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(2), enable(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables Path AIS Alarm forwarding upon a failure detection. The
|
|
following might be considered as a failure: LOS, LOF, LOC, SLM,
|
|
LOP, Path AIS and Line AIS.
|
|
|
|
disable(2) - will not forward an alarm upon a failure on this port.
|
|
|
|
enable(3) - will forward an alarm upon a failure on this port."
|
|
::= { atmNteConfIfEntry 9 }
|
|
|
|
atmConfIfAllocatedBw OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total VC Bandwidth Allocation."
|
|
::= { atmNteConfIfEntry 10 }
|
|
|
|
atmConfIfLowerVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Lower possible VPI."
|
|
::= { atmNteConfIfEntry 11 }
|
|
|
|
atmConfIfOamMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- intermediate(1),
|
|
segmentTermination(2),
|
|
endToEndTermination(3)
|
|
-- vpEndToEndVcSegment(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM support Mode, which determines the
|
|
interface's location in a segment wise."
|
|
::= { atmNteConfIfEntry 12 }
|
|
|
|
atmNteAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteAlarmIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface Alarm table."
|
|
::= { atmNtePrtConfig 2 }
|
|
|
|
atmNteAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX AtmNteAlarmIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the interface Alarm table."
|
|
INDEX { ifIndex}
|
|
::= { atmNteAlarmIfTable 1 }
|
|
|
|
AtmNteAlarmIfEntry ::=
|
|
SEQUENCE {
|
|
atmInterfaceActiveAlarms
|
|
Integer32,
|
|
atmThresholdSectionBIP
|
|
Integer32,
|
|
atmThresholdLineBIP
|
|
Integer32,
|
|
atmThresholdLineFEBE
|
|
Integer32,
|
|
atmThresholdPathBIP
|
|
Integer32,
|
|
atmThresholdPathFEBE
|
|
Integer32,
|
|
atmThresholdErroredCells
|
|
Integer32,
|
|
atmThresholdLostCells
|
|
Integer32,
|
|
atmThresholdMisinsertedCells
|
|
Integer32,
|
|
atmInterfaceAlarmStatus
|
|
INTEGER,
|
|
atmInterfaceMaskAlarms
|
|
Integer32
|
|
}
|
|
|
|
atmInterfaceActiveAlarms OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Bit String of the active alarms on this interface.
|
|
An up bit (1) means there is an active alarm of this
|
|
type. A down bit (0) means there is no such alarm.
|
|
The meaning of the bits is as follows:
|
|
1 - LOS
|
|
2 - LOF
|
|
3 - Line AIS (SONET)/ PLCP LOF (DS3)
|
|
4 - LOP
|
|
5 - Path AIS
|
|
6 - SLM
|
|
7 - LCD
|
|
8 - Line RDI (SONET)/ PLCP Yellow (DS3)
|
|
9 - Path RDI (SONET)/ RDI (DS3)
|
|
10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold
|
|
11 - Line BIP (SONET)/ PLCP BIP (DS3) > Threshold
|
|
12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold
|
|
13 - Path BIP > Threshold
|
|
14 - Path FEBE > Threshold
|
|
15 - HW Failure
|
|
"
|
|
::= { atmNteAlarmIfEntry 1 }
|
|
|
|
atmThresholdSectionBIP OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Section BIPs are greater than this threshold,
|
|
an active alarm is raised. N/A for ds3/e3 interface."
|
|
::= { atmNteAlarmIfEntry 2 }
|
|
|
|
atmThresholdLineBIP OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Line BIPs are greater than this threshold,
|
|
an active alarm is raised. N/A for ds3/e3 interface."
|
|
::= { atmNteAlarmIfEntry 3 }
|
|
|
|
atmThresholdLineFEBE OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Line FEBEs are greater than this threshold,
|
|
an active alarm is raised. N/A for ds3/e3 interface."
|
|
::= { atmNteAlarmIfEntry 4 }
|
|
|
|
atmThresholdPathBIP OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Path BIPs are greater than this threshold,
|
|
an active alarm is raised."
|
|
::= { atmNteAlarmIfEntry 5 }
|
|
|
|
atmThresholdPathFEBE OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Path FEBEs are greater than this threshold,
|
|
an active alarm is raised."
|
|
::= { atmNteAlarmIfEntry 6 }
|
|
|
|
atmThresholdErroredCells OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Errored Cells are greater than this threshold,
|
|
an active alarm is raised."
|
|
::= { atmNteAlarmIfEntry 7 }
|
|
|
|
atmThresholdLostCells OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Lost Cells are greater than this threshold,
|
|
an active alarm is raised."
|
|
::= { atmNteAlarmIfEntry 8 }
|
|
|
|
atmThresholdMisinsertedCells OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Misinserted Cells are greater than this threshold,
|
|
an active alarm is raised."
|
|
::= { atmNteAlarmIfEntry 9 }
|
|
|
|
|
|
|
|
atmInterfaceAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { off(2),
|
|
on(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The variable is on(3) when there is any active alarm
|
|
on this interface."
|
|
::= { atmNteAlarmIfEntry 10 }
|
|
|
|
atmInterfaceMaskAlarms OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Bit String of alarms mask on this interface.
|
|
An up bit (1) means that the respective alarm is masked.
|
|
A down bit (0) means no mask.
|
|
The mask is supported for the following alarms:
|
|
1 - LOS
|
|
"
|
|
::= { atmNteAlarmIfEntry 11 }
|
|
|
|
|
|
atmNteConfVpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteConfVpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VP configuration table.
|
|
The table is an extension to the atmVplTable of
|
|
RFC-1695."
|
|
::= { atmNtePrtConfig 3 }
|
|
|
|
atmNteConfVpEntry OBJECT-TYPE
|
|
SYNTAX AtmNteConfVpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VP configuration table.
|
|
ifIndex of the ATM layer."
|
|
INDEX { ifIndex, atmVplVpi }
|
|
::= { atmNteConfVpTable 1 }
|
|
|
|
AtmNteConfVpEntry ::=
|
|
SEQUENCE {
|
|
atmConfVpPolicing INTEGER,
|
|
atmConfVpCCAdminStatus INTEGER,
|
|
atmConfVpLoopbackAdminStatus INTEGER,
|
|
atmConfVpLoopbackSinkAddress OCTET STRING,
|
|
atmConfVpCongestionControl OCTET STRING,
|
|
atmConfVpCCDirection INTEGER,
|
|
atmConfVpCreationTime DateAndTime,
|
|
atmConfVpOamSupport INTEGER,
|
|
atmConfVpCCOperStatus INTEGER,
|
|
atmConfVpLoopbackTraffic INTEGER,
|
|
atmConfVpLoopbackFailureInd INTEGER,
|
|
atmConfVpLoopbackFailureThreshold Integer32,
|
|
atmConfVpOamDirection INTEGER
|
|
}
|
|
|
|
atmConfVpPolicing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
police(2),
|
|
monitor(3),
|
|
shaping(4),
|
|
policingAndShaping(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Policing method desired for this VPL."
|
|
::= { atmNteConfVpEntry 1 }
|
|
|
|
atmConfVpCCAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (2),
|
|
down (3),
|
|
source(4), -- agent send Oam CC cells
|
|
sink (5), -- agent check received Oam CC cells
|
|
listenToActivationCells (6),
|
|
originateActivationCells(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"up(2) - Activate Continuity Check (CC).
|
|
down(3) - Deactivate CC.
|
|
source(4) - Activate OAM CC(Continuity Check) of local agent
|
|
( start sending Oam cells to the remote side ).
|
|
sink(5) - Activate CC of remote agent ( start receiving Oam cells from
|
|
remote side ).
|
|
listenToActivationCells (6) - Passive listener till gets an activation request
|
|
originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection."
|
|
::= {atmNteConfVpEntry 2}
|
|
|
|
atmConfVpLoopbackAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(2),
|
|
down(3),
|
|
llid(4),
|
|
segment(5),
|
|
endToEnd(6),
|
|
segmentLlid(7),
|
|
endToEndLlid(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"up(2) - Start loopback OAM cells.
|
|
down(3) - Stop sending loopback OAM cells.
|
|
|
|
For ace2002:
|
|
up(2) - Transmitting LB cells with llid all ones
|
|
(i.e. FFFF..FF)
|
|
down(3) - Not transmitting LB cells.
|
|
llid(4) - Transmitting LB cells with llid indicated
|
|
in the address field.
|
|
segment(5) - Transmitting Segment LB cells with llid
|
|
all ones.
|
|
endToEnd(6) - Transmitting End to End LB cells with llid
|
|
all ones.
|
|
segmentLlid(7) - Transmitting Segment LB cells with
|
|
llid indicated in the address field.
|
|
endToEndLlid(8) - Transmitting LB cells with llid
|
|
indicated in the address field.
|
|
|
|
This parameter value might be in conflict with
|
|
atmConfVpOamSupport value, since this parameter is for LB,
|
|
while atmConfVpOamSupport is for any other OAM cells."
|
|
::= {atmNteConfVpEntry 3}
|
|
|
|
atmConfVpLoopbackSinkAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination address.
|
|
For ace101: 2 bytes are used.
|
|
For ace2002: 16 bytes are used."
|
|
::= {atmNteConfVpEntry 4}
|
|
|
|
atmConfVpCongestionControl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each bit indicates a selection of one option
|
|
as the following description. All combinations
|
|
are possible and legal.
|
|
The codes are:
|
|
1 - EPD
|
|
2 - CLP
|
|
4 - EFCI"
|
|
::= {atmNteConfVpEntry 5}
|
|
|
|
atmConfVpCCDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
both (2),
|
|
source(4),
|
|
sink (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"both(2) - Agent send OAM CC cells and check received OAM CC cells
|
|
source(4)- Agent send OAM CC cells.
|
|
sink(5) - Agent checks received OAM CC cells."
|
|
::= {atmNteConfVpEntry 6}
|
|
|
|
atmConfVpCreationTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A date-time in which the VP was created."
|
|
::= { atmNteConfVpEntry 7 }
|
|
|
|
atmConfVpOamSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
intermediate(1),
|
|
segmentTermination(2),
|
|
endToEndTermination(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM support mode, which determines the device location
|
|
in a segment wise."
|
|
::= { atmNteConfVpEntry 8 }
|
|
|
|
|
|
atmConfVpCCOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
initial (1),
|
|
source(4),
|
|
sink (5),
|
|
both (8),
|
|
timeout (9),
|
|
denied (10),
|
|
conflict (11),
|
|
manual (12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
initial(1) - The CC activation process is not started.
|
|
source(4) - Agent sends OAM CC cells.
|
|
sink(5) - Agent checks received OAM CC cells.
|
|
both (8) - OAM CC of local and remote agents activation.
|
|
timeout (9) - Timeout occured on receiving answer from
|
|
the remote agent.
|
|
denied (10) - CC activation process rejected by remote agent.
|
|
conflict (11) - local and remote sides requested activation
|
|
simultaneously.
|
|
manual (12) - OAM CC of local agent activated manually.
|
|
"
|
|
::= {atmNteConfVpEntry 9}
|
|
|
|
atmConfVpLoopbackTraffic OBJECT-TYPE
|
|
SYNTAX INTEGER { off(2), on(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter has both command and status meanings:
|
|
off(2) - Set to 'Off' will Stop traffic loop. Getting this
|
|
value means that the loop is not running.
|
|
on (3) - Set to 'On' will start traffic loop. Getting
|
|
this value means that the loop is currently running."
|
|
::= {atmNteConfVpEntry 10}
|
|
|
|
atmConfVpLoopbackFailureInd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(2),
|
|
segmentAis(3),
|
|
segmentRdi(4),
|
|
segmentAisAndRdi(5),
|
|
endToEndAis(6),
|
|
endToEndRdi(7),
|
|
endToEndAisAndRdi(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows user to define the Indication that will be created upon
|
|
a LB cell failure.
|
|
disabled(2) - no indication will be created.
|
|
segmentAis(3) - will cause Tx of a segment AIS.
|
|
segmentRdi(4) - will cause Tx of a segment RDI.
|
|
segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI.
|
|
endToEndAis(6) - will cause Tx of an End to End AIS.
|
|
endToEndRdi(7) - will cause Tx of an End to End RDI.
|
|
endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI.
|
|
Default: disabled(2)."
|
|
::= {atmNteConfVpEntry 11}
|
|
|
|
atmConfVpLoopbackFailureThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the LB failures before starting transmission of the
|
|
Indication defined by atmConfVcLoopbackFailureInd.
|
|
Range: 1..16. Default: 1."
|
|
::= {atmNteConfVpEntry 12}
|
|
|
|
atmConfVpOamDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
downStream (2),
|
|
upStream (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of OAM cell insertion.
|
|
downStream(2) - The OAM cell will be inserted in downStream.
|
|
upStream(3) - The OAM cell will be inserted in upStream."
|
|
::= {atmNteConfVpEntry 13}
|
|
|
|
|
|
--Alarm Table
|
|
atmNteAlarmVpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteAlarmVpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VP Alarm table."
|
|
::= { atmNtePrtConfig 5 }
|
|
|
|
atmNteAlarmVpEntry OBJECT-TYPE
|
|
SYNTAX AtmNteAlarmVpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VP Alarm table.
|
|
ifIndex of the ATM layer."
|
|
INDEX { ifIndex, atmNteVpAlarmVpi}
|
|
::= { atmNteAlarmVpTable 1 }
|
|
|
|
AtmNteAlarmVpEntry ::=
|
|
SEQUENCE {
|
|
atmNteVpAlarmVpi
|
|
Integer32,
|
|
atmNteVpActiveAlarms
|
|
Integer32
|
|
}
|
|
|
|
atmNteVpAlarmVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI on which there is an active alarm."
|
|
::= { atmNteAlarmVpEntry 1 }
|
|
|
|
atmNteVpActiveAlarms OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Bit String of the active alarms on this VP.
|
|
An up bit (1) means there is an active alarm of this
|
|
type. A down bit (0) means there is no such alarm.
|
|
The meaning of the bits is as follows:
|
|
1 - VP AIS
|
|
2 - VP Loss Of Continuity
|
|
3 - VP RDI Reception
|
|
4 - VP Errored Cells > Threshold
|
|
5 - VP Lost Cells > Threshold
|
|
6 - VP Misinserted Cells > Threshold
|
|
9 - VP Loopback Failure
|
|
"
|
|
::= { atmNteAlarmVpEntry 2 }
|
|
|
|
atmNteAlarmVcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteAlarmVcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VC Alarm table."
|
|
::= { atmNtePrtConfig 6 }
|
|
|
|
atmNteAlarmVcEntry OBJECT-TYPE
|
|
SYNTAX AtmNteAlarmVcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VC Alarm table.
|
|
ifIndex of the ATM layer."
|
|
INDEX { ifIndex, atmNteVcAlarmVpi, atmNteVcAlarmVci}
|
|
::= { atmNteAlarmVcTable 1 }
|
|
|
|
AtmNteAlarmVcEntry ::=
|
|
SEQUENCE {
|
|
atmNteVcAlarmVpi
|
|
Integer32,
|
|
atmNteVcAlarmVci
|
|
Integer32,
|
|
atmNteVcActiveAlarms
|
|
Integer32
|
|
}
|
|
|
|
atmNteVcAlarmVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VC on which there is an active alarm."
|
|
::= { atmNteAlarmVcEntry 1 }
|
|
|
|
atmNteVcAlarmVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the VC on which there is an active alarm."
|
|
::= { atmNteAlarmVcEntry 2 }
|
|
|
|
atmNteVcActiveAlarms OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Bit String of the active alarms on this VC.
|
|
An up bit (1) means there is an active alarm of this
|
|
type. A down bit (0) means there is no such alarm.
|
|
The meaning of the bits is as follows:
|
|
1 - VC AIS
|
|
2 - VC Loss Of Continuity
|
|
3 - VC RDI
|
|
4 - VC Errored Cells > Threshold
|
|
5 - VC Lost Cells > Threshold
|
|
6 - VC Misinserted Cells > Threshold
|
|
7 - Tx VC AIS
|
|
8 - Tx VC RDI
|
|
9 - VC Loopback Failure
|
|
"
|
|
::= { atmNteAlarmVcEntry 3 }
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\atm\confVcTa.txt
|
|
--
|
|
-- file : ConfVcTable.txt
|
|
--
|
|
--Version: 1.0
|
|
--Date: 12.11.97
|
|
--By: Ilana Schvetz
|
|
--File: v:\doc\rdv\mib\ver495\atm\ConfVcTable.txt
|
|
|
|
--Last Update: 15-Dec-02 by Shay Harari.
|
|
|
|
-- *******************************************************
|
|
-- Configuration Vc Table
|
|
-- *******************************************************
|
|
|
|
--atmNte OBJECT IDENTIFIER ::= { radAtm 3 }
|
|
--atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 }
|
|
--atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 }
|
|
|
|
|
|
atmNteConfVcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteConfVcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VC configuration table.
|
|
The table is an extension to the atmVclTable of
|
|
RFC-1695."
|
|
::= { atmNtePrtConfig 4 }
|
|
|
|
atmNteConfVcEntry OBJECT-TYPE
|
|
SYNTAX AtmNteConfVcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VC configuration table.
|
|
ifIndex of the ATM layer."
|
|
INDEX { ifIndex , atmVclVpi, atmVclVci}
|
|
::= { atmNteConfVcTable 1 }
|
|
|
|
AtmNteConfVcEntry ::=
|
|
SEQUENCE {
|
|
atmConfVcPolicing INTEGER,
|
|
atmConfVcCCAdminStatus INTEGER,
|
|
atmConfVcLoopbackAdminStatus INTEGER,
|
|
atmConfVcLoopbackSinkAddress OCTET STRING,
|
|
atmConfVcCongestionControl OCTET STRING,
|
|
atmConfVcCCDirection INTEGER,
|
|
atmConfVcCreationTime DateAndTime,
|
|
atmConfVcOamSupport INTEGER,
|
|
atmConfVcCCActivationCtrl INTEGER,
|
|
atmConfVcCCOperStatus INTEGER,
|
|
atmConfVcLoopbackTraffic INTEGER,
|
|
atmConfVcLoopbackFailureInd INTEGER,
|
|
atmConfVcLoopbackFailureThreshold Integer32,
|
|
atmConfVcOamDirection INTEGER,
|
|
atmConfVcName DisplayString,
|
|
atmConfVcConnected INTEGER
|
|
}
|
|
|
|
atmConfVcPolicing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
police(2),
|
|
monitor(3),
|
|
shaping(4),
|
|
policingAndShaping(5),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Policing method desired for this VCL."
|
|
::= { atmNteConfVcEntry 1 }
|
|
|
|
atmConfVcCCAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(2),
|
|
down(3),
|
|
source(4), -- agent send Oam CC cells
|
|
sink(5), -- agent check received Oam CC cells
|
|
listenToActivationCells (6),
|
|
originateActivationCells(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"up(2) - Activate Continuity Check (CC).
|
|
down(3) - Deactivate CC.
|
|
source(4) - Activate OAM CC(Continuity Check) of local agent
|
|
( start sending Oam cells to the remote side ).
|
|
sink(5) - Activate CC of remote agent ( start receiving Oam cells from
|
|
remote side).
|
|
listenToActivationCells (6) - Passive listener till gets an activation request
|
|
originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection."
|
|
::= {atmNteConfVcEntry 2}
|
|
|
|
atmConfVcLoopbackAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(2),
|
|
down(3),
|
|
llid(4),
|
|
segment(5),
|
|
endToEnd(6),
|
|
segmentLlid(7),
|
|
endToEndLlid(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"up(2) - Start loopback OAM cells.
|
|
down(3) - Stop sending loopback OAM cells.
|
|
|
|
For ace2002:
|
|
up(2) - Transmitting LB cells with llid all ones
|
|
(i.e. FFFF..FF)
|
|
down(3) - Not transmitting LB cells.
|
|
llid(4) - Transmitting LB cells with llid indicated
|
|
in the address field.
|
|
segment(5) - Transmitting Segment LB cells with llid
|
|
all ones.
|
|
endToEnd(6) - Transmitting End to End LB cells with llid
|
|
all ones.
|
|
segmentLlid(7) - Transmitting Segment LB cells with
|
|
llid indicated in the address field.
|
|
endToEndLlid(8) - Transmitting LB cells with llid
|
|
indicated in the address field.
|
|
|
|
This parameter value might be in conflict with
|
|
atmConfVcOamSupport value, since this parameter is for LB,
|
|
while atmConfVcOamSupport is for any other OAM cells."
|
|
::= {atmNteConfVcEntry 3}
|
|
|
|
atmConfVcLoopbackSinkAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination address.
|
|
For ace101: 2 bytes are used.
|
|
For ace2002: 16 bytes are used."
|
|
::= {atmNteConfVcEntry 4}
|
|
|
|
atmConfVcCongestionControl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each bit indicates a selection of one option
|
|
as the following description. All combinations
|
|
are possible and legal.
|
|
The codes are:
|
|
1 - EPD
|
|
2 - CLP
|
|
4 - EFCI.
|
|
For ace2002:
|
|
1 - Packet Discard."
|
|
::= {atmNteConfVcEntry 5}
|
|
|
|
atmConfVcCCDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
both (2),
|
|
none (3),
|
|
source(4),
|
|
sink (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"both(2) - Agent send OAM CC cells and check receivev OAM CC cells
|
|
none(3) - Agent does not send and does not check received OAM CC cells.
|
|
source(4)- Agent send OAM CC cells.
|
|
sink(5) - Agent checks received OAM CC cells."
|
|
::= {atmNteConfVcEntry 6}
|
|
|
|
atmConfVcCreationTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A date-time in which the VC was created."
|
|
::= { atmNteConfVcEntry 7 }
|
|
|
|
atmConfVcOamSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
intermediate(1),
|
|
segmentTermination(2),
|
|
endToEndTermination(3),
|
|
segmentAndEndToEnd(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM support mode, which determines the device location
|
|
in a segment wise.
|
|
|
|
segmentAndEndToEnd - In this mode the OAM cells are generated
|
|
before the ABM (ATM Buffer Manager), so
|
|
that the PCR and CDVT will not be affected."
|
|
::= { atmNteConfVcEntry 8 }
|
|
|
|
atmConfVcCCActivationCtrl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual(1),
|
|
activator(2),
|
|
listener(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"manual(1) - CC Activation process is disable
|
|
activator(2) - ACE-101 initiate CC Activation process
|
|
listener(3) - ACE-101 wait to CC Activation request from remote side."
|
|
::= { atmNteConfVcEntry 9 }
|
|
|
|
atmConfVcCCOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
initial(1),
|
|
up(2),
|
|
down(3),
|
|
source(4), -- agent send Oam CC cells
|
|
sink(5), -- agent check received Oam CC cells
|
|
both (8),
|
|
timeout (9),
|
|
denied (10),
|
|
conflict (11),
|
|
manual (12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"initial (1) - The CC activation process is not started.
|
|
up (2) - Continuity Check (CC) activated.
|
|
down (3) - CC deactivated.
|
|
source (4) - OAM CC(Continuity Check) of local agent activated.
|
|
sink (5) - OAM CC of remote agent activated.
|
|
both (8) - OAM CC of local and remote agents activation.
|
|
timeout (9) - Timeout occured on receiving answer from
|
|
the remote agent.
|
|
denied (10) - CC activation process rejected by remote agent.
|
|
conflict (11) - local and remote sides requested activation
|
|
simultaneously.
|
|
manual (12) - OAM CC of local agent activated manually.
|
|
"
|
|
::= { atmNteConfVcEntry 10 }
|
|
|
|
atmConfVcLoopbackTraffic OBJECT-TYPE
|
|
SYNTAX INTEGER { off(2), on(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter has both command and status meanings:
|
|
off(2) - Set to 'Off' will Stop traffic loop. Getting this
|
|
value means that the loop is not running.
|
|
on (3) - Set to 'On' will start traffic loop. Getting
|
|
this value means that the loop is currently running."
|
|
::= {atmNteConfVcEntry 11}
|
|
|
|
atmConfVcLoopbackFailureInd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(2),
|
|
segmentAis(3),
|
|
segmentRdi(4),
|
|
segmentAisAndRdi(5),
|
|
endToEndAis(6),
|
|
endToEndRdi(7),
|
|
endToEndAisAndRdi(8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows user to define the Indication that will be created upon
|
|
a LB cell failure.
|
|
disabled(2) - no indication will be created.
|
|
segmentAis(3) - will cause Tx of a segment AIS.
|
|
segmentRdi(4) - will cause Tx of a segment RDI.
|
|
segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI.
|
|
endToEndAis(6) - will cause Tx of an End to End AIS.
|
|
endToEndRdi(7) - will cause Tx of an End to End RDI.
|
|
endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI.
|
|
Default: disabled(2)."
|
|
::= {atmNteConfVcEntry 12}
|
|
|
|
atmConfVcLoopbackFailureThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the LB failures before starting transmission of the
|
|
Indication defined by atmConfVcLoopbackFailureInd.
|
|
Range: 1..16. Default: 1."
|
|
::= {atmNteConfVcEntry 13}
|
|
|
|
atmConfVcOamDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
downStream (2),
|
|
upStream (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of OAM cell insertion.
|
|
downStream(2) - The OAM cell will be inserted in downStream.
|
|
upStream(3) - The OAM cell will be inserted in upStream."
|
|
::= {atmNteConfVcEntry 14}
|
|
|
|
atmConfVcName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VC Name."
|
|
::= {atmNteConfVcEntry 15}
|
|
|
|
atmConfVcConnected OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notConnected(1),
|
|
mng(2),
|
|
bridgePort(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether this VC is connected."
|
|
::= {atmNteConfVcEntry 16}
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver485\atm\radima.txt
|
|
--
|
|
-- RAD-IMA-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--Title: RAD-IMA MIB
|
|
--
|
|
-- Copyright 1998 RAD Data Communications, Ltd.
|
|
-- All Rights Reserved.
|
|
|
|
-- IMPORTS
|
|
|
|
-- OBJECT-TYPE FROM RFC-1212
|
|
-- radWan FROM RAD-GEN-MIB;
|
|
-- RAD-IMA MIB
|
|
|
|
--Title: RAD's IMA INTERFACE MIB
|
|
--Version: 1.0
|
|
--Date: 15.09.98
|
|
--By: Ilana Schvetz
|
|
--File: radima.mib
|
|
|
|
-- Last Update 20.01.02 by Ilana Schvetz
|
|
|
|
|
|
radAtmIma OBJECT IDENTIFIER ::= {radAtm 5}
|
|
|
|
imaPrimaryClk OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
link1(2),
|
|
link2(3),
|
|
link3(4),
|
|
link4(5),
|
|
automatic(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock source to be transmitted to the user side,
|
|
where user module is in 'External' clock source."
|
|
::= { radAtmIma 1 }
|
|
|
|
-- An extension to the Link Table
|
|
|
|
|
|
imaXLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ImaXLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IMA Link Status and Configuration table.
|
|
This table contains additional objects for the link table."
|
|
::= { radAtmIma 2 }
|
|
|
|
imaXLinkEntry OBJECT-TYPE
|
|
SYNTAX ImaXLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IMA Link table."
|
|
-- AUGMENTS { imaLinkTable }
|
|
INDEX { imaLinkIfIndex }
|
|
::= { imaXLinkTable 1 }
|
|
|
|
ImaXLinkEntry ::=
|
|
SEQUENCE {
|
|
imaLinkDirection INTEGER,
|
|
imaLinkItcLBClkSrc INTEGER
|
|
}
|
|
|
|
|
|
|
|
imaLinkDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rx(1),
|
|
tx(2),
|
|
both(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the Link direction."
|
|
-- DEFAULT { both }
|
|
::= { imaXLinkEntry 1 }
|
|
|
|
imaLinkItcLBClkSrc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
link1(1),
|
|
link2(2),
|
|
link3(3),
|
|
link4(4),
|
|
internal (5),
|
|
external (6),
|
|
automatic(7),
|
|
loopback (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock source for the current Tx-line."
|
|
::= { imaXLinkEntry 2 }
|
|
|
|
-- An extension to the Group Table
|
|
|
|
|
|
imaXGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ImaXGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IMA group Status and Configuration table.
|
|
This table contains additional objects for the Group table."
|
|
::= { radAtmIma 3 }
|
|
|
|
imaXGroupEntry OBJECT-TYPE
|
|
SYNTAX ImaXGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the IMA Group table."
|
|
-- AUGMENTS { imaGroupTable }
|
|
INDEX { imaGroupIndex }
|
|
::= { imaXGroupTable 1 }
|
|
|
|
ImaXGroupEntry ::=
|
|
SEQUENCE {
|
|
imaGroupVersion INTEGER,
|
|
imaGroupCtcTxClkSrc INTEGER,
|
|
imaGroupCtcTxClkSrcPort Integer32
|
|
}
|
|
|
|
|
|
imaGroupVersion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ver10(1),
|
|
ver11(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IMA Version."
|
|
::= { imaXGroupEntry 1 }
|
|
|
|
imaGroupCtcTxClkSrc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
link1 (1),
|
|
link2 (2),
|
|
link3 (3),
|
|
link4 (4),
|
|
internal (5),
|
|
external (6),
|
|
automatic (7),
|
|
loopback (8),
|
|
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source of the transmitted, common, Clock Source.
|
|
Applicable if imaGroupNeTxClkMode=ctc(1).
|
|
Automatic - Dynamic source, taken from the currently reference link.
|
|
Internal - taken from the Internal clock on card.
|
|
Loopback - Looped back from one of the ports. In this case a specific
|
|
port should be selected for imaGroupCtcTxClkSrcPort parameter.
|
|
Link N - Clock will be looped from one of the links."
|
|
::= { imaXGroupEntry 2 }
|
|
|
|
imaGroupCtcTxClkSrcPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is valid only when imaGroupCtcTxClkSrc=loopback.
|
|
The value may be any port identifier."
|
|
::= { imaXGroupEntry 3 }
|
|
|
|
-- IMA Traps
|
|
|
|
--NOTIFICATIONS
|
|
|
|
atmImaGroupStatusChangeTrap NOTIFICATION-TYPE
|
|
OBJECTS { imaGroupFailureStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates IMA Group status change."
|
|
::= { radSysAtmEvents 80 }
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\radhdlc.txt
|
|
--
|
|
-- RAD-HDLC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--Title: RAD-HDLC MIB
|
|
--
|
|
-- Copyright 1998 RAD Data Communications, Ltd.
|
|
-- All Rights Reserved.
|
|
|
|
|
|
--Title: RAD's HDLC MIB
|
|
--Version: 1.0
|
|
--Date: 15.09.98
|
|
--By: Ilana Schvetz
|
|
--File: radhdlc.mib
|
|
--
|
|
-- Last Update: 09-Oct-02 By Ilana Schvetz
|
|
|
|
hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5}
|
|
|
|
hdlcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HdlcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The HDLC configuration table."
|
|
::= { hdlcMibObjects 1 }
|
|
|
|
hdlcEntry OBJECT-TYPE
|
|
SYNTAX HdlcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the contents of each line in the RAD HDLC Table."
|
|
INDEX { ifIndex }
|
|
::= { hdlcTable 1 }
|
|
|
|
HdlcEntry ::=
|
|
SEQUENCE {
|
|
hdlcProtocol INTEGER,
|
|
hdlcRateResolution INTEGER,
|
|
hdlcTxClockSource INTEGER,
|
|
hdlcTerminalMode INTEGER,
|
|
hdlcLoopbackState INTEGER,
|
|
hdlcTxClockPolarity INTEGER,
|
|
hdlcFlowControl INTEGER,
|
|
hdlcLineRate Integer32,
|
|
hdlcRxClockMode INTEGER,
|
|
hdlcLOF Gauge32,
|
|
hdlcRxClockPolarity INTEGER
|
|
}
|
|
|
|
|
|
|
|
hdlcProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
v35(2),
|
|
x21(3),
|
|
rs530(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The HDLC protocol type
|
|
V35 - HDLC encapsulated over V35
|
|
X21 - HDLC encapsulated over X21
|
|
RS530 - HDLC encapsulated over RS530"
|
|
::= { hdlcEntry 1 }
|
|
|
|
|
|
|
|
hdlcRateResolution OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
nx56Kbps(2),
|
|
nx64Kbps(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The baud rate of the internal clock."
|
|
::= { hdlcEntry 2 }
|
|
|
|
|
|
hdlcTxClockSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internal(1),
|
|
external(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The baud rate of the internal clock."
|
|
::= { hdlcEntry 3 }
|
|
|
|
hdlcTerminalMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dce(1),
|
|
dte(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { hdlcEntry 4 }
|
|
|
|
hdlcLoopbackState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
internal(2),
|
|
external(3),
|
|
disable(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"internal - All data coming from the
|
|
network port is looped back
|
|
external - All data comming from the line is
|
|
looped back."
|
|
::= { hdlcEntry 5 }
|
|
|
|
|
|
hdlcTxClockPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
inverse(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"normal - The transmitted data is sampled at the middle of bit time
|
|
inverse - The transmitted data is sampled at the end of the bit time
|
|
(high data rate/long cable)."
|
|
::= { hdlcEntry 6 }
|
|
|
|
hdlcFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable the CTS/RTS flow control signals."
|
|
::= { hdlcEntry 7 }
|
|
|
|
|
|
hdlcLineRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rate values for HDLC are n*56/64Kbps, where 1<=n<=32, 64, 128
|
|
and the following values: 1544, 3088, 6176.
|
|
The rate values for HSSI is nMbps, where 1<=n<=52."
|
|
::= { hdlcEntry 8 }
|
|
|
|
|
|
hdlcRxClockMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
internal (2),
|
|
external (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { hdlcEntry 9 }
|
|
|
|
|
|
hdlcLOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of seconds the port is in Loss Of Frame state."
|
|
::= { hdlcEntry 10 }
|
|
|
|
|
|
hdlcRxClockPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
inverse(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"normal - The received data is sampled at the middle of bit time
|
|
inverse - The received data is sampled at the end of the bit time
|
|
(high data rate/long cable)."
|
|
::= { hdlcEntry 11 }
|
|
|
|
|
|
hdlcPerformance OBJECT IDENTIFIER ::= {hdlcMibObjects 2}
|
|
|
|
|
|
hdlcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HdlcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The HDLC Current table."
|
|
::= { hdlcPerformance 1 }
|
|
|
|
hdlcCurrentEntry OBJECT-TYPE
|
|
SYNTAX HdlcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the HDLC Current table."
|
|
INDEX { hdlcCurrentIfIndex }
|
|
::= { hdlcCurrentTable 1 }
|
|
|
|
HdlcCurrentEntry ::=
|
|
SEQUENCE {
|
|
hdlcCurrentIfIndex
|
|
Integer32,
|
|
hdlcCurrentStatus
|
|
OCTET STRING,
|
|
hdlcCurrentLOF
|
|
Gauge32,
|
|
hdlcCurrentInFrames
|
|
Gauge32,
|
|
hdlcCurrentInErrors
|
|
Gauge32,
|
|
hdlcCurrentOutFrames
|
|
Gauge32,
|
|
hdlcCurrentAbortedFrames
|
|
Gauge32,
|
|
hdlcCurrentLengthError
|
|
Gauge32
|
|
}
|
|
|
|
hdlcCurrentIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the HDLC interface.
|
|
It may be ifIndex."
|
|
::= { hdlcCurrentEntry 1 }
|
|
|
|
hdlcCurrentStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - Valid.
|
|
1 - redundantLinkSwitch - the link has been switched
|
|
by a redundancy mechanism.
|
|
2 - discontinuity - module was partialy out.
|
|
4 - notValid - module is out."
|
|
::= { hdlcCurrentEntry 2 }
|
|
|
|
hdlcCurrentLOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of seconds the
|
|
port is in Loss Of Frame state, encountered
|
|
by the HDLC interface in the current 15 minute interval."
|
|
::= { hdlcCurrentEntry 3 }
|
|
|
|
hdlcCurrentInFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames,
|
|
encountered by the HDLC interface in the current 15 minute
|
|
interval."
|
|
::= { hdlcCurrentEntry 4 }
|
|
|
|
hdlcCurrentInErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Errored received
|
|
frames, encountered by the HDLC interface in the current 15
|
|
minute interval."
|
|
::= { hdlcCurrentEntry 5 }
|
|
|
|
hdlcCurrentOutFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted frames,
|
|
encountered by the HDLC interface in the current 15 minute
|
|
interval."
|
|
::= { hdlcCurrentEntry 6 }
|
|
|
|
hdlcCurrentAbortedFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of frames, in which
|
|
at least seven consecutive '1'-s (Abort sequence) were
|
|
encountered by the HDLC interface in the current 15 minute
|
|
interval."
|
|
::= { hdlcCurrentEntry 7 }
|
|
|
|
hdlcCurrentLengthError OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames
|
|
with length error, encountered by the HDLC interface in the
|
|
current 15 minute interval."
|
|
::= { hdlcCurrentEntry 8 }
|
|
|
|
|
|
--Interval Table
|
|
|
|
|
|
hdlcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HdlcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The HDLC Interval table."
|
|
::= { hdlcPerformance 2 }
|
|
|
|
hdlcIntervalEntry OBJECT-TYPE
|
|
SYNTAX HdlcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the HDLC Interval table."
|
|
INDEX { hdlcIntervalIfIndex, hdlcIntervalNumber }
|
|
::= { hdlcIntervalTable 1 }
|
|
|
|
HdlcIntervalEntry ::=
|
|
SEQUENCE {
|
|
hdlcIntervalIfIndex
|
|
Integer32,
|
|
hdlcIntervalNumber
|
|
Integer32,
|
|
hdlcIntervalStatus
|
|
OCTET STRING,
|
|
hdlcIntervalLOF
|
|
Gauge32,
|
|
hdlcIntervalInFrames
|
|
Gauge32,
|
|
hdlcIntervalInErrors
|
|
Gauge32,
|
|
hdlcIntervalOutFrames
|
|
Gauge32,
|
|
hdlcIntervalAbortedFrames
|
|
Gauge32,
|
|
hdlcIntervalLengthError
|
|
Gauge32
|
|
}
|
|
|
|
hdlcIntervalIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the HDLC interface.
|
|
It may be ifIndex."
|
|
::= { hdlcIntervalEntry 1 }
|
|
|
|
hdlcIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals exist)."
|
|
::= { hdlcIntervalEntry 2 }
|
|
|
|
hdlcIntervalStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - Valid.
|
|
1 - redundantLinkSwitch - the link has been switched
|
|
by a redundancy mechanism.
|
|
2 - discontinuity - module was partialy out.
|
|
4 - notValid - module is out."
|
|
::= { hdlcIntervalEntry 3 }
|
|
|
|
hdlcIntervalLOF OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of seconds the
|
|
port is in Loss Of Frame state, encountered by an HDLC
|
|
interface in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { hdlcIntervalEntry 4 }
|
|
|
|
hdlcIntervalInFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames,
|
|
encountered by the HDLC interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { hdlcIntervalEntry 5 }
|
|
|
|
hdlcIntervalInErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Errored received
|
|
frames, encountered by the HDLC interface in one of the
|
|
previous 96, individual 15 minute, intervals."
|
|
::= { hdlcIntervalEntry 6 }
|
|
|
|
hdlcIntervalOutFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
frames, encountered by the HDLC interface in one of
|
|
the previous 96, individual 15 minute, intervals."
|
|
::= { hdlcIntervalEntry 7 }
|
|
|
|
hdlcIntervalAbortedFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of frames, in which
|
|
at least seven consecutive '1'-s (Abort sequence) were
|
|
encountered by the HDLC interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { hdlcIntervalEntry 8 }
|
|
|
|
hdlcIntervalLengthError OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames
|
|
with length error, encountered by the HDLC interface in
|
|
one of the previous 96, individual 15 minute, intervals."
|
|
::= { hdlcIntervalEntry 9 }
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver525\atm\ace101.txt
|
|
--
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver525\ATM\ace101.txt
|
|
|
|
--RAD-ARC-MIB
|
|
|
|
-- DEFINITIONS ::= BEGIN
|
|
|
|
--Title: RAD-ACE MIB
|
|
--
|
|
|
|
-- IMPORTS
|
|
-- Gauge32, IpAddress FROM RFC1155-SMI
|
|
-- ifIndex FROM IF-MIB
|
|
-- OBJECT-TYPE FROM RFC-1212
|
|
-- TRAP-TYPE FROM RFC-1215
|
|
-- radAtm, agnLed, agnIndication FROM RAD-GEN-MIB
|
|
-- RowStatus FROM SNMPv2-TC
|
|
-- atmVplVpi, atmVclVpi, atmVclVci FROM ATM-MIB;
|
|
|
|
|
|
|
|
-- RAD-ACE MIB
|
|
|
|
--Title: RAD's ARC ATM PRODUCT MIB
|
|
--Version: 1.0
|
|
--Date: 24.9.96
|
|
--By: Yair Arian
|
|
--File: arc.mib
|
|
--
|
|
--Last update: 19-Dec-2005 by Ilana Schvetz
|
|
|
|
atmGen OBJECT IDENTIFIER ::= {radAtm 2}
|
|
|
|
atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1}
|
|
|
|
atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1}
|
|
-- aal5VccXTable ::= { atmIfPerformance 4 } in aal5.txt
|
|
|
|
|
|
atmIfDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmIfDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM interface Data table."
|
|
::= { atmIfPerformance 1 }
|
|
|
|
atmIfDataEntry OBJECT-TYPE
|
|
SYNTAX AtmIfDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM interface Data table."
|
|
INDEX { ifIndex }
|
|
::= { atmIfDataTable 1 }
|
|
|
|
AtmIfDataEntry ::=
|
|
SEQUENCE {
|
|
atmIfTimeElapsed
|
|
Integer32,
|
|
atmIfValidIntervals
|
|
Integer32
|
|
}
|
|
|
|
atmIfTimeElapsed OBJECT-TYPE
|
|
SYNTAX Integer32 (0..899)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds that have elapsed since
|
|
the beginning of the near end current error-
|
|
measurement period."
|
|
::= { atmIfDataEntry 1 }
|
|
|
|
atmIfValidIntervals OBJECT-TYPE
|
|
SYNTAX Integer32 (0..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of previous near end intervals for
|
|
which valid data was collected. The value will be
|
|
96 unless the interface was brought online within
|
|
the last 24 hours, in which case the value will be
|
|
the number of complete 15 minute near end
|
|
intervals since the interface has been online."
|
|
::= { atmIfDataEntry 2 }
|
|
|
|
|
|
-- the ATM interface Current
|
|
|
|
-- The ATM interface current table contains various statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
atmIfCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmIfCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM interface Current table."
|
|
::= { atmIfPerformance 2 }
|
|
|
|
atmIfCurrentEntry OBJECT-TYPE
|
|
SYNTAX AtmIfCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM interface Current table."
|
|
INDEX { ifIndex }
|
|
::= { atmIfCurrentTable 1 }
|
|
|
|
AtmIfCurrentEntry ::=
|
|
SEQUENCE {
|
|
atmIfCurrentTxCells
|
|
Gauge32,
|
|
atmIfCurrentRxCells
|
|
Gauge32,
|
|
atmIfCurrentCorrectedHecs
|
|
Gauge32,
|
|
atmIfCurrentUncorrectedHecs
|
|
Gauge32,
|
|
atmIfCurrentHecErrorSeconds
|
|
Gauge32
|
|
}
|
|
|
|
atmIfCurrentTxCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
cells, encountered by an ATM interface in
|
|
the current 15 minute interval."
|
|
::= { atmIfCurrentEntry 1 }
|
|
|
|
atmIfCurrentRxCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
cells, encountered by an ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmIfCurrentEntry 2 }
|
|
|
|
atmIfCurrentCorrectedHecs OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of cells with
|
|
corrected HEC errors, encountered by an
|
|
ATM interface in the current 15 minute
|
|
interval."
|
|
::= { atmIfCurrentEntry 3 }
|
|
|
|
atmIfCurrentUncorrectedHecs OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of cells with
|
|
uncorrected HEC errors, encountered by an ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmIfCurrentEntry 4 }
|
|
|
|
atmIfCurrentHecErrorSeconds OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of seconds with
|
|
HEC errors, encountered by an ATM interface in
|
|
the current 15 minute interval."
|
|
::= { atmIfCurrentEntry 5 }
|
|
|
|
|
|
-- the ATM interface Interval
|
|
|
|
-- The ATM interface Interval Table contains various statistics
|
|
-- collected by each ATM Interface over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
atmIfIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmIfIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM interface Interval table."
|
|
::= { atmIfPerformance 3 }
|
|
|
|
atmIfIntervalEntry OBJECT-TYPE
|
|
SYNTAX AtmIfIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM interface Interval table."
|
|
INDEX { ifIndex, atmIfIntervalNumber }
|
|
::= { atmIfIntervalTable 1 }
|
|
|
|
AtmIfIntervalEntry ::=
|
|
SEQUENCE {
|
|
atmIfIntervalNumber
|
|
Integer32,
|
|
atmIfIntervalTxCells
|
|
Gauge32,
|
|
atmIfIntervalRxCells
|
|
Gauge32,
|
|
atmIfIntervalCorrectedHecs
|
|
Gauge32,
|
|
atmIfIntervalUncorrectedHecs
|
|
Gauge32,
|
|
atmIfIntervalHecErrorSeconds
|
|
Gauge32
|
|
}
|
|
|
|
atmIfIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { atmIfIntervalEntry 1 }
|
|
|
|
atmIfIntervalTxCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
cells , encountered by an ATM interface in
|
|
one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { atmIfIntervalEntry 2 }
|
|
|
|
atmIfIntervalRxCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
cells, encountered by an ATM
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmIfIntervalEntry 3 }
|
|
|
|
atmIfIntervalCorrectedHecs OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of cells with
|
|
corrected HEC errors, encountered by an
|
|
ATM interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { atmIfIntervalEntry 4 }
|
|
|
|
atmIfIntervalUncorrectedHecs OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of cells with
|
|
uncorrected HEC errors, encountered by an ATM
|
|
interface in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmIfIntervalEntry 5 }
|
|
|
|
atmIfIntervalHecErrorSeconds OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of seconds with
|
|
HEC errors, encountered by an ATM interface in one of
|
|
the previous 96, individual 15 minute, intervals."
|
|
::= { atmIfIntervalEntry 6 }
|
|
|
|
|
|
atmPvcPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 2}
|
|
|
|
atmVpPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 1}
|
|
|
|
-- the ATM VP Current
|
|
|
|
-- The ATM VP current table contains various statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
atmVpCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VP Current table."
|
|
::= { atmVpPerformance 1 }
|
|
|
|
atmVpCurrentEntry OBJECT-TYPE
|
|
SYNTAX AtmVpCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VP Current table."
|
|
INDEX { ifIndex, atmVpCurrentVpi }
|
|
::= { atmVpCurrentTable 1 }
|
|
|
|
AtmVpCurrentEntry ::=
|
|
SEQUENCE {
|
|
atmVpCurrentVpi
|
|
Integer32,
|
|
atmVpCurrentRxCellsClp01
|
|
Gauge32,
|
|
atmVpCurrentRxCellsClp0
|
|
Gauge32,
|
|
atmVpCurrentGcra0Violations
|
|
Gauge32,
|
|
atmVpCurrentGcra1Violations
|
|
Gauge32,
|
|
atmVpCurrentRxAIS
|
|
Gauge32,
|
|
atmVpCurrentTxAIS
|
|
Gauge32,
|
|
atmVpCurrentRxRDI
|
|
Gauge32,
|
|
atmVpCurrentTxRDI
|
|
Gauge32,
|
|
atmVpCurrentContinuityLoss
|
|
Gauge32,
|
|
atmVpCurrentUAS
|
|
Gauge32,
|
|
atmVpCurrentSES
|
|
Gauge32,
|
|
atmVpCurrentCDC
|
|
Gauge32,
|
|
atmVpCurrentTotalDiscards
|
|
Gauge32,
|
|
atmVpCurrentClp0Discards
|
|
Gauge32,
|
|
atmVpCurrentTotalCellOuts
|
|
Gauge32,
|
|
atmVpCurrentClp0CellOuts
|
|
Gauge32,
|
|
atmVpCurrentTaggedOuts
|
|
Gauge32,
|
|
atmVpCurrentPCR
|
|
Gauge32,
|
|
atmVpCurrentSCR
|
|
Gauge32,
|
|
atmVpCurrentMCR
|
|
Gauge32,
|
|
atmVpCurrentShaperTotalDiscards
|
|
Gauge32,
|
|
atmVpCurrentShaperClp0Discards
|
|
Gauge32,
|
|
atmVpCurrentShaperClp1Discards
|
|
Gauge32
|
|
}
|
|
|
|
atmVpCurrentVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VPL."
|
|
::= { atmVpCurrentEntry 1 }
|
|
|
|
atmVpCurrentRxCellsClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
cells, encountered by the VPL of this ATM interface in
|
|
the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 2 }
|
|
|
|
atmVpCurrentRxCellsClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 3 }
|
|
|
|
atmVpCurrentGcra0Violations OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of cells
|
|
violating GCRA0, encountered by the VPL of this
|
|
ATM interface in the current 15 minute
|
|
interval."
|
|
::= { atmVpCurrentEntry 4 }
|
|
|
|
atmVpCurrentGcra1Violations OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of cells
|
|
violating GCRA1, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 5 }
|
|
|
|
atmVpCurrentRxAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
AIS cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 6 }
|
|
|
|
atmVpCurrentTxAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
AIS cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval. Not Supported
|
|
in the first phase."
|
|
::= { atmVpCurrentEntry 7 }
|
|
|
|
atmVpCurrentRxRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
RDI cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 8 }
|
|
|
|
atmVpCurrentTxRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
RDI cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 9 }
|
|
|
|
atmVpCurrentContinuityLoss OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of loss of
|
|
continuity cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 10 }
|
|
|
|
atmVpCurrentUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Unavailable
|
|
Seconds, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 11 }
|
|
|
|
atmVpCurrentSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severerly Errored
|
|
Seconds, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpCurrentEntry 12 }
|
|
|
|
atmVpCurrentCDC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of cells dropped in the current 15 minute interval
|
|
of the VP connection."
|
|
::= { atmVpCurrentEntry 13 }
|
|
|
|
atmVpCurrentTotalDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells discarded by
|
|
the traffic policing entity. This includes cells
|
|
originally received with CLP=0 and CLP=1."
|
|
::= { atmVpCurrentEntry 14 }
|
|
|
|
atmVpCurrentClp0Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells received with
|
|
CLP=0 and discarded by the traffic policing
|
|
entity."
|
|
::= { atmVpCurrentEntry 15 }
|
|
|
|
atmVpCurrentTotalCellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells transmitted
|
|
by this VPL. This includes both CLP=0 and CLP=1
|
|
cells."
|
|
::= { atmVpCurrentEntry 16 }
|
|
|
|
atmVpCurrentClp0CellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells transmitted
|
|
with CLP=0 by this VPL."
|
|
::= { atmVpCurrentEntry 17 }
|
|
|
|
atmVpCurrentTaggedOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells tagged by the
|
|
traffic policing entity from CLP=0 to CLP=1 and
|
|
transmitted by this VPL."
|
|
::= { atmVpCurrentEntry 18 }
|
|
|
|
atmVpCurrentPCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum traffic rate encountered in the
|
|
last interval of the VP connection (monitored once a second)."
|
|
::= { atmVpCurrentEntry 19 }
|
|
|
|
atmVpCurrentSCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average traffic rate during the last interval of the VP
|
|
connection."
|
|
::= { atmVpCurrentEntry 20 }
|
|
|
|
atmVpCurrentMCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MCR - The minimum traffic rate encountered in the last
|
|
interval of the VP connection (monitored once a second)."
|
|
::= { atmVpCurrentEntry 21 }
|
|
|
|
atmVpCurrentShaperTotalDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of cells (CLP0 and CLP1) discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVpCurrentEntry 22 }
|
|
|
|
atmVpCurrentShaperClp0Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of CLP0 cells discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVpCurrentEntry 23 }
|
|
|
|
atmVpCurrentShaperClp1Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of CLP1 cells discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVpCurrentEntry 24 }
|
|
|
|
|
|
-- The ATM VP current table for Performance Management
|
|
-- which contains various statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
atmVpPMCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpPMCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VP Current table for Performance Management."
|
|
::= { atmVpPerformance 2 }
|
|
|
|
atmVpPMCurrentEntry OBJECT-TYPE
|
|
SYNTAX AtmVpPMCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VP Current table for Performance
|
|
Management."
|
|
INDEX { ifIndex, atmVpPMCurrentVpi, atmVpPMCurrentDir }
|
|
::= { atmVpPMCurrentTable 1 }
|
|
|
|
AtmVpPMCurrentEntry ::=
|
|
SEQUENCE {
|
|
atmVpPMCurrentDir
|
|
INTEGER,
|
|
atmVpPMCurrentVpi
|
|
Integer32,
|
|
atmVpPMCurrentTxClp01
|
|
Gauge32,
|
|
atmVpPMCurrentTxClp0
|
|
Gauge32,
|
|
atmVpPMCurrentRxClp01
|
|
Gauge32,
|
|
atmVpPMCurrentRxClp0
|
|
Gauge32,
|
|
atmVpPMCurrentErroredCells
|
|
Gauge32,
|
|
atmVpPMCurrentLostCells
|
|
Gauge32,
|
|
atmVpPMCurrentMisinsertedCells
|
|
Gauge32,
|
|
atmVpPMCurrentECB
|
|
Gauge32,
|
|
atmVpPMCurrentSECB
|
|
Gauge32,
|
|
atmVpPMCurrentES
|
|
Gauge32,
|
|
atmVpPMCurrentSES
|
|
Gauge32,
|
|
atmVpPMCurrentUAS
|
|
Gauge32,
|
|
atmVpPMCurrentIntervalQuality
|
|
INTEGER,
|
|
atmVpPMCurrentLastDayQuality
|
|
INTEGER
|
|
}
|
|
|
|
atmVpPMCurrentVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VPL."
|
|
::= { atmVpPMCurrentEntry 1 }
|
|
|
|
atmVpPMCurrentDir OBJECT-TYPE
|
|
SYNTAX INTEGER {forward(2), backward(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of performance management."
|
|
::= { atmVpPMCurrentEntry 2 }
|
|
|
|
atmVpPMCurrentTxClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
CLP 0+1 cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 3 }
|
|
|
|
atmVpPMCurrentTxClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
CLP 0 cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 4 }
|
|
|
|
atmVpPMCurrentRxClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
CLP 0+1 cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 5 }
|
|
|
|
atmVpPMCurrentRxClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
CLP 0 cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 6 }
|
|
|
|
atmVpPMCurrentErroredCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of errored
|
|
cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 7 }
|
|
|
|
atmVpPMCurrentLostCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of lost
|
|
cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 8 }
|
|
|
|
atmVpPMCurrentMisinsertedCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of misinserted
|
|
cells, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 9 }
|
|
|
|
atmVpPMCurrentECB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of ECB,
|
|
encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 10 }
|
|
|
|
atmVpPMCurrentSECB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SECB,
|
|
encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 11 }
|
|
|
|
atmVpPMCurrentES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
Errored Seconds, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 12 }
|
|
|
|
atmVpPMCurrentSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severely
|
|
Errored Seconds, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 13 }
|
|
|
|
atmVpPMCurrentUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Unavailable
|
|
Seconds, encountered by the VPL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVpPMCurrentEntry 14 }
|
|
|
|
atmVpPMCurrentIntervalQuality OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(2), unacceptable(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the number of errors per interval is superior to
|
|
the atmNteUPLTCR value, the quality of service of
|
|
the interval is declared as unacceptable."
|
|
DEFVAL { normal }
|
|
::= { atmVpPMCurrentEntry 15 }
|
|
|
|
atmVpPMCurrentLastDayQuality OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(2), degraded(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the number of errors per 24 hours is superior to
|
|
the atmNteDPLTCR value, the quality of service of
|
|
the day is declared as degraded."
|
|
DEFVAL { normal }
|
|
::= { atmVpPMCurrentEntry 16 }
|
|
|
|
|
|
-- the ATM VP Interval
|
|
|
|
-- The ATM VP Interval Table contains various statistics
|
|
-- collected by each ATM Interface/VP over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
atmVpIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM Vp Interval table."
|
|
::= { atmVpPerformance 3 }
|
|
|
|
atmVpIntervalEntry OBJECT-TYPE
|
|
SYNTAX AtmVpIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM Vp Interval table."
|
|
INDEX { ifIndex, atmVpIntervalVpi,
|
|
atmVpIntervalNumber }
|
|
::= { atmVpIntervalTable 1 }
|
|
|
|
AtmVpIntervalEntry ::=
|
|
SEQUENCE {
|
|
atmVpIntervalVpi
|
|
Integer32,
|
|
atmVpIntervalNumber
|
|
Integer32,
|
|
atmVpIntervalRxCellsClp01
|
|
Gauge32,
|
|
atmVpIntervalRxCellsClp0
|
|
Gauge32,
|
|
atmVpIntervalGcra0Violations
|
|
Gauge32,
|
|
atmVpIntervalGcra1Violations
|
|
Gauge32,
|
|
atmVpIntervalRxAIS
|
|
Gauge32,
|
|
atmVpIntervalTxAIS
|
|
Gauge32,
|
|
atmVpIntervalRxRDI
|
|
Gauge32,
|
|
atmVpIntervalTxRDI
|
|
Gauge32,
|
|
atmVpIntervalContinuityLoss
|
|
Gauge32,
|
|
atmVpIntervalUAS
|
|
Gauge32,
|
|
atmVpIntervalSES
|
|
Gauge32,
|
|
atmVpIntervalCDC
|
|
Gauge32,
|
|
atmVpIntervalTotalDiscards
|
|
Gauge32,
|
|
atmVpIntervalClp0Discards
|
|
Gauge32,
|
|
atmVpIntervalTotalCellOuts
|
|
Gauge32,
|
|
atmVpIntervalClp0CellOuts
|
|
Gauge32,
|
|
atmVpIntervalTaggedOuts
|
|
Gauge32,
|
|
atmVpIntervalPCR
|
|
Gauge32,
|
|
atmVpIntervalSCR
|
|
Gauge32,
|
|
atmVpIntervalMCR
|
|
Gauge32,
|
|
atmVpIntervalShaperTotalDiscards
|
|
Gauge32,
|
|
atmVpIntervalShaperClp0Discards
|
|
Gauge32,
|
|
atmVpIntervalShaperClp1Discards
|
|
Gauge32
|
|
}
|
|
|
|
atmVpIntervalVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VPL."
|
|
::= { atmVpIntervalEntry 1 }
|
|
|
|
atmVpIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { atmVpIntervalEntry 2 }
|
|
|
|
atmVpIntervalRxCellsClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
cells , encountered by an ATM interface/VP in
|
|
one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { atmVpIntervalEntry 3 }
|
|
|
|
atmVpIntervalRxCellsClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 4 }
|
|
|
|
atmVpIntervalGcra0Violations OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
cells violating GCRA0, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 5 }
|
|
|
|
atmVpIntervalGcra1Violations OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
cells violating GCRA1, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 6 }
|
|
|
|
atmVpIntervalRxAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
AIS cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 7 }
|
|
|
|
atmVpIntervalTxAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
AIS cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals. Not supported in the first phase."
|
|
::= { atmVpIntervalEntry 8 }
|
|
|
|
atmVpIntervalRxRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
RDI cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 9 }
|
|
|
|
atmVpIntervalTxRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
RDI cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 10 }
|
|
|
|
atmVpIntervalContinuityLoss OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Continuity
|
|
Loss cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 11 }
|
|
|
|
atmVpIntervalUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Unavailable
|
|
Seconds, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 12 }
|
|
|
|
atmVpIntervalSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severerly Errored
|
|
Seconds, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpIntervalEntry 13 }
|
|
|
|
atmVpIntervalCDC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of cells dropped in the 15 minute interval
|
|
of the VP connection."
|
|
::= { atmVpIntervalEntry 14 }
|
|
|
|
atmVpIntervalTotalDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells discarded by
|
|
the traffic policing entity. This includes cells
|
|
originally received with CLP=0 and CLP=1."
|
|
::= { atmVpIntervalEntry 15 }
|
|
|
|
atmVpIntervalClp0Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells received with
|
|
CLP=0 an discarded by the traffic policing
|
|
entity."
|
|
::= { atmVpIntervalEntry 16 }
|
|
|
|
atmVpIntervalTotalCellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells transmitted
|
|
by this VPL. This includes both CLP=0 and CLP=1
|
|
cells."
|
|
::= { atmVpIntervalEntry 17 }
|
|
|
|
|
|
atmVpIntervalClp0CellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells transmitted
|
|
with CLP=0 by this VPL."
|
|
::= { atmVpIntervalEntry 18 }
|
|
|
|
atmVpIntervalTaggedOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells tagged by the
|
|
traffic policing entity from CLP=0 to CLP=1 and
|
|
transmitted by this VPL."
|
|
::= { atmVpIntervalEntry 19 }
|
|
|
|
atmVpIntervalPCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum traffic rate encountered in the last
|
|
interval of the VP connection (monitored once a second)
|
|
encountered by an ATM interface/VP in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { atmVpIntervalEntry 20 }
|
|
|
|
atmVpIntervalSCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average traffic rate during the last interval of the
|
|
VP connection , encountered by an ATM interface/VP in one
|
|
of the previous 96, individual 15 minute, intervals."
|
|
::= { atmVpIntervalEntry 21 }
|
|
|
|
atmVpIntervalMCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MCR - The minimum traffic rate encountered in the last
|
|
interval of the VP connection (monitored once a second)
|
|
encountered by an ATM interface/VP in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { atmVpIntervalEntry 22 }
|
|
|
|
atmVpIntervalShaperTotalDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of cells (CLP0 and CLP1) discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVpIntervalEntry 23 }
|
|
|
|
atmVpIntervalShaperClp0Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of CLP0 cells discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVpIntervalEntry 24 }
|
|
|
|
atmVpIntervalShaperClp1Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of CLP1 cells discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVpIntervalEntry 25 }
|
|
|
|
|
|
-- The ATM VP Interval Table for Performance Management
|
|
-- contains various statistics
|
|
-- collected by each ATM Interface/VP over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
atmVpPMIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpPMIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM Vp Interval table for Performance Management."
|
|
::= { atmVpPerformance 4 }
|
|
|
|
atmVpPMIntervalEntry OBJECT-TYPE
|
|
SYNTAX AtmVpPMIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM Vp Interval table for Performance
|
|
Management."
|
|
INDEX { ifIndex, atmVpPMIntervalVpi, atmVpPMIntervalDir, atmVpPMIntervalNumber }
|
|
::= { atmVpPMIntervalTable 1 }
|
|
|
|
AtmVpPMIntervalEntry ::=
|
|
SEQUENCE {
|
|
atmVpPMIntervalVpi
|
|
Integer32,
|
|
atmVpPMIntervalDir
|
|
INTEGER,
|
|
atmVpPMIntervalNumber
|
|
Integer32,
|
|
atmVpPMIntervalTxClp01
|
|
Gauge32,
|
|
atmVpPMIntervalTxClp0
|
|
Gauge32,
|
|
atmVpPMIntervalRxClp01
|
|
Gauge32,
|
|
atmVpPMIntervalRxClp0
|
|
Gauge32,
|
|
atmVpPMIntervalErroredCells
|
|
Gauge32,
|
|
atmVpPMIntervalLostCells
|
|
Gauge32,
|
|
atmVpPMIntervalMisinsertedCells
|
|
Gauge32,
|
|
atmVpPMIntervalECB
|
|
Gauge32,
|
|
atmVpPMIntervalSECB
|
|
Gauge32,
|
|
atmVpPMIntervalES
|
|
Gauge32,
|
|
atmVpPMIntervalSES
|
|
Gauge32,
|
|
atmVpPMIntervalUAS
|
|
Gauge32,
|
|
atmVpPMIntervalQuality
|
|
INTEGER,
|
|
atmVpPMIntervalLastDayQuality
|
|
INTEGER
|
|
}
|
|
|
|
atmVpPMIntervalVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VPL."
|
|
::= { atmVpPMIntervalEntry 1 }
|
|
|
|
atmVpPMIntervalDir OBJECT-TYPE
|
|
SYNTAX INTEGER {forward(2),
|
|
backward(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of performance management."
|
|
::= { atmVpPMIntervalEntry 2 }
|
|
|
|
atmVpPMIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { atmVpPMIntervalEntry 3 }
|
|
|
|
atmVpPMIntervalTxClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
CLP 0+1 cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 4 }
|
|
|
|
atmVpPMIntervalTxClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
CLP 0 cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 5 }
|
|
|
|
atmVpPMIntervalRxClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
CLP 0+1 cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 6 }
|
|
|
|
atmVpPMIntervalRxClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
CLP 0 cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 7 }
|
|
|
|
atmVpPMIntervalErroredCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Errored
|
|
cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 8 }
|
|
|
|
atmVpPMIntervalLostCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Lost
|
|
cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 9 }
|
|
|
|
atmVpPMIntervalMisinsertedCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Misinserted
|
|
cells, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 10 }
|
|
|
|
atmVpPMIntervalECB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of ECBs
|
|
encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 11 }
|
|
|
|
atmVpPMIntervalSECB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SECBs
|
|
encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 12 }
|
|
|
|
atmVpPMIntervalES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Errored
|
|
Seconds, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 13 }
|
|
|
|
atmVpPMIntervalSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severely
|
|
Errored Seconds, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 14 }
|
|
|
|
atmVpPMIntervalUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Unavailable
|
|
Seconds, encountered by an ATM
|
|
interface/VP in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVpPMIntervalEntry 15 }
|
|
|
|
atmVpPMIntervalQuality OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(2), unacceptable(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the number of errors per interval is superior to
|
|
the atmNteUPLTCR value, the quality of service of
|
|
the interval is declared as unacceptable."
|
|
DEFVAL { normal }
|
|
::= { atmVpPMIntervalEntry 16}
|
|
|
|
atmVpPMIntervalLastDayQuality OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(2), degraded(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the number of errors per 24 hours is superior to
|
|
the atmNteDPLTCR value, the quality of service of
|
|
the day is declared as degraded."
|
|
DEFVAL { normal }
|
|
::= { atmVpPMIntervalEntry 17}
|
|
|
|
-- VP QoS Table
|
|
|
|
atmVpQoSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpQoSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VP QoS table."
|
|
::= { atmVpPerformance 5 }
|
|
|
|
atmVpQoSEntry OBJECT-TYPE
|
|
SYNTAX AtmVpQoSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
INDEX { ifIndex, atmVplVpi, atmVpQoSPeriodRef }
|
|
::= { atmVpQoSTable 1 }
|
|
|
|
AtmVpQoSEntry ::=
|
|
SEQUENCE {
|
|
atmVpQoSPeriodRef INTEGER,
|
|
atmVpQoSElapsedTime Integer32,
|
|
atmVpQoSUAS Gauge32
|
|
}
|
|
|
|
atmVpQoSPeriodRef OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
currentPeriod (1),
|
|
lastPeriod (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index that specifies which period of time, the next
|
|
2 objects refer to.
|
|
currentPeriod - the period since last systemResetAllStatsCmd received or
|
|
since Start-up (if no systemResetAllStatsCmd was received since
|
|
Start-up) until now.
|
|
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
|
|
- If only one command occurred since Start-up: the period between
|
|
Start-up and last command.
|
|
- If no command occurred since Start-up: this period will not
|
|
actually exist. In this case, he following 5 objects will be 0."
|
|
::= { atmVpQoSEntry 1 }
|
|
|
|
atmVpQoSElapsedTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Elapsed Time in seconds.
|
|
- for atmVpQoSPeriodRef = currentPeriod:
|
|
The period since last systemResetAllStatsCmd received or since Start-up
|
|
(if no systemResetAllStatsCmd was received since Start-up) until now.
|
|
- for atmVpQoSPeriodRef = lastPeriod:
|
|
The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd
|
|
was received."
|
|
::= { atmVpQoSEntry 2 }
|
|
|
|
atmVpQoSUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef)."
|
|
::= { atmVpQoSEntry 3 }
|
|
|
|
-- VP PM QoS Table
|
|
|
|
atmVpPMQoSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpPMQoSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PM VP QoS table."
|
|
::= { atmVpPerformance 6 }
|
|
|
|
atmVpPMQoSEntry OBJECT-TYPE
|
|
SYNTAX AtmVpPMQoSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
INDEX { ifIndex, atmVplVpi, atmVpPMQoSDirection ,atmVpPMQoSPeriodRef }
|
|
::= { atmVpPMQoSTable 1 }
|
|
|
|
AtmVpPMQoSEntry ::=
|
|
SEQUENCE {
|
|
atmVpPMQoSDirection INTEGER,
|
|
atmVpPMQoSPeriodRef INTEGER,
|
|
atmVpPMQoSCLR Gauge32,
|
|
atmVpPMQoSCER Gauge32,
|
|
atmVpPMQoSCMR Gauge32
|
|
}
|
|
|
|
atmVpPMQoSDirection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
forward (2),
|
|
backward (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of performance management."
|
|
::= { atmVpPMQoSEntry 1 }
|
|
|
|
atmVpPMQoSPeriodRef OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
currentPeriod (1),
|
|
lastPeriod (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index that specifies which period of time, the next
|
|
5 objects refer to.
|
|
currentPeriod - the period since last systemResetAllStatsCmd received or
|
|
since Start-up (if no systemResetAllStatsCmd was received since
|
|
Start-up) until now.
|
|
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
|
|
- If only one command occurred since Start-up: the period between
|
|
Start-up and last command.
|
|
- If no command occurred since Start-up: this period will not
|
|
actually exist. In this case, he following 5 objects will be 0."
|
|
::= { atmVpPMQoSEntry 2 }
|
|
|
|
|
|
atmVpPMQoSCLR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)-
|
|
defined in accordance with I.356 , in %.
|
|
The value will be multipuled by 100."
|
|
::= { atmVpPMQoSEntry 3 }
|
|
|
|
atmVpPMQoSCER OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef)
|
|
defined in accordance with I.356 , in %.
|
|
The value will be multipuled by 100."
|
|
::= { atmVpPMQoSEntry 4 }
|
|
|
|
atmVpPMQoSCMR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef)
|
|
defined in accordance with I.356 , cells/sec ."
|
|
::= { atmVpPMQoSEntry 5 }
|
|
|
|
--VP Shaper Statistics Table
|
|
atmVpShaperStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpShaperStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VP shaper statistics table."
|
|
::= { atmVpPerformance 7 }
|
|
|
|
atmVpShaperStatEntry OBJECT-TYPE
|
|
SYNTAX AtmVpShaperStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VP shaper statistics table."
|
|
INDEX { ifIndex, atmVplVpi }
|
|
::= { atmVpShaperStatTable 1 }
|
|
|
|
AtmVpShaperStatEntry ::=
|
|
SEQUENCE {
|
|
atmVpShaperDiscarded Counter32,
|
|
atmVpShaperOccupation Integer32,
|
|
atmVpShaperMaxOccupation Integer32,
|
|
atmVpShaperLevel INTEGER,
|
|
atmVpShaperEpdDropped Counter32,
|
|
atmVpShaperTotalEpdDropped Counter32
|
|
}
|
|
|
|
|
|
atmVpShaperDiscarded OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Cells that were discarded in the shaper on that VPC due
|
|
to buffer overflow.
|
|
This counter counts till it reaches its MAX value (20 bits) and then
|
|
rolls over."
|
|
::= { atmVpShaperStatEntry 1 }
|
|
|
|
atmVpShaperOccupation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Cells that are currently stored in the buffer.
|
|
This parameter is limited to 20 bits."
|
|
::= { atmVpShaperStatEntry 2}
|
|
|
|
atmVpShaperMaxOccupation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Maximum number of Cells that were stored in the buffer,
|
|
since this VP was activated. This parameter is limited to 20 bits."
|
|
::= { atmVpShaperStatEntry 3}
|
|
|
|
atmVpShaperLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
empty (1),
|
|
full (2),
|
|
below (3),
|
|
above (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The occupation of the buffer according to a predefined threshold.
|
|
empty - buffer is Empty
|
|
full - buffer is Full
|
|
below - buffer is Below the threshold
|
|
above - buffer is Above the threshold. This is also the trigger to
|
|
start EPD\PPD mechanism, if set for the VPC."
|
|
::= { atmVpShaperStatEntry 4}
|
|
|
|
atmVpShaperEpdDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Cells that were dropped in the shaper on that VPC
|
|
due to EPD\PPD mechanism in the last second.
|
|
This parameter is limited to 24 bits.
|
|
Applicable for a EPD/PPD VP only."
|
|
::= { atmVpShaperStatEntry 5}
|
|
|
|
atmVpShaperTotalEpdDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Total number of Cells that were dropped in the shaper on that
|
|
VPC due to EPD\PPD mechanism in the last 15 minutes. This counter
|
|
automatically reset itself every 15 minutes.
|
|
Applicable for a EPD/PPD VP only."
|
|
::= { atmVpShaperStatEntry 6}
|
|
|
|
|
|
atmVcPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 2}
|
|
|
|
-- the ATM VC Current
|
|
|
|
-- The ATM VC current table contains various statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
atmVcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VC Current table."
|
|
::= { atmVcPerformance 1 }
|
|
|
|
atmVcCurrentEntry OBJECT-TYPE
|
|
SYNTAX AtmVcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VC Current table."
|
|
INDEX { ifIndex, atmVcCurrentVpi, atmVcCurrentVci }
|
|
::= { atmVcCurrentTable 1 }
|
|
|
|
AtmVcCurrentEntry ::=
|
|
SEQUENCE {
|
|
atmVcCurrentVpi
|
|
Integer32,
|
|
atmVcCurrentVci
|
|
Integer32,
|
|
atmVcCurrentRxCellsClp01
|
|
Gauge32,
|
|
atmVcCurrentRxCellsClp0
|
|
Gauge32,
|
|
atmVcCurrentGcra0Violations
|
|
Gauge32,
|
|
atmVcCurrentGcra1Violations
|
|
Gauge32,
|
|
atmVcCurrentRxAIS
|
|
Gauge32,
|
|
atmVcCurrentTxAIS
|
|
Gauge32,
|
|
atmVcCurrentRxRDI
|
|
Gauge32,
|
|
atmVcCurrentTxRDI
|
|
Gauge32,
|
|
atmVcCurrentContinuityLoss
|
|
Gauge32,
|
|
atmVcCurrentUAS
|
|
Gauge32,
|
|
atmVcCurrentSES
|
|
Gauge32,
|
|
atmVcCurrentCDC
|
|
Gauge32,
|
|
atmVcCurrentTotalDiscards
|
|
Gauge32,
|
|
atmVcCurrentClp0Discards
|
|
Gauge32,
|
|
atmVcCurrentTotalCellOuts
|
|
Gauge32,
|
|
atmVcCurrentClp0CellOuts
|
|
Gauge32,
|
|
atmVcCurrentTaggedOuts
|
|
Gauge32,
|
|
atmVcCurrentPCR
|
|
Gauge32,
|
|
atmVcCurrentSCR
|
|
Gauge32,
|
|
atmVcCurrentMCR
|
|
Gauge32,
|
|
atmVcCurrentShaperTotalDiscards
|
|
Gauge32,
|
|
atmVcCurrentShaperClp0Discards
|
|
Gauge32,
|
|
atmVcCurrentShaperClp1Discards
|
|
Gauge32
|
|
}
|
|
|
|
atmVcCurrentVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VCL."
|
|
::= { atmVcCurrentEntry 1 }
|
|
|
|
atmVcCurrentVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the VCL."
|
|
::= { atmVcCurrentEntry 2 }
|
|
|
|
atmVcCurrentRxCellsClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
cells, encountered by the VCL of this ATM interface in
|
|
the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 3 }
|
|
|
|
atmVcCurrentRxCellsClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 4 }
|
|
|
|
atmVcCurrentGcra0Violations OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of cells
|
|
violating GCRA0, encountered by the VCL of this
|
|
ATM interface in the current 15 minute
|
|
interval."
|
|
::= { atmVcCurrentEntry 5 }
|
|
|
|
atmVcCurrentGcra1Violations OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of cells
|
|
violating GCRA1, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 6 }
|
|
|
|
atmVcCurrentRxAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
AIS cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 7 }
|
|
|
|
atmVcCurrentTxAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
AIS cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval. Not Supported
|
|
in the first phase."
|
|
::= { atmVcCurrentEntry 8 }
|
|
|
|
atmVcCurrentRxRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
RDI cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 9 }
|
|
|
|
atmVcCurrentTxRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
RDI cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 10 }
|
|
|
|
atmVcCurrentContinuityLoss OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of loss of
|
|
continuity cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 11 }
|
|
|
|
atmVcCurrentUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Unavailable
|
|
Seconds, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 12 }
|
|
|
|
|
|
atmVcCurrentSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severerly Errored
|
|
Seconds, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcCurrentEntry 13 }
|
|
|
|
atmVcCurrentCDC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of cells dropped in the current 15 minute interval
|
|
of the VC connection."
|
|
::= { atmVcCurrentEntry 14 }
|
|
|
|
atmVcCurrentTotalDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells discarded by
|
|
the traffic policing entity. This includes cells
|
|
originally received with CLP=0 and CLP=1."
|
|
::= { atmVcCurrentEntry 15 }
|
|
|
|
atmVcCurrentClp0Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells received with
|
|
CLP=0 an discarded by the traffic policing
|
|
entity."
|
|
::= { atmVcCurrentEntry 16 }
|
|
|
|
atmVcCurrentTotalCellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells transmitted
|
|
by this VPL. This includes both CLP=0 and CLP=1
|
|
cells."
|
|
::= { atmVcCurrentEntry 17 }
|
|
|
|
atmVcCurrentClp0CellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells transmitted
|
|
with CLP=0 by this VPL."
|
|
::= { atmVcCurrentEntry 18 }
|
|
|
|
atmVcCurrentTaggedOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells tagged by the
|
|
traffic policing entity from CLP=0 to CLP=1 and
|
|
transmitted by this VPL."
|
|
::= { atmVcCurrentEntry 19 }
|
|
|
|
atmVcCurrentPCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum traffic rate encountered in the last
|
|
interval of the VC connection (monitored once a second)."
|
|
::= { atmVcCurrentEntry 20 }
|
|
|
|
atmVcCurrentSCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average traffic rate during the last interval
|
|
of the VC connection."
|
|
::= { atmVcCurrentEntry 21 }
|
|
|
|
atmVcCurrentMCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MCR - The minimum traffic rate encountered in the last
|
|
interval of the VC connection (monitored once a second)."
|
|
::= { atmVcCurrentEntry 22 }
|
|
|
|
atmVcCurrentShaperTotalDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of cells (CLP0 and CLP1) discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVcCurrentEntry 23 }
|
|
|
|
atmVcCurrentShaperClp0Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of CLP0 cells discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVcCurrentEntry 24 }
|
|
|
|
atmVcCurrentShaperClp1Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of CLP1 cells discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVcCurrentEntry 25 }
|
|
|
|
|
|
-- The ATM VC current table for Performance Management
|
|
-- which contains various statistics being
|
|
-- collected for the current 15 minute interval.
|
|
|
|
atmVcPMCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcPMCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VC Current table for Performance Management."
|
|
::= { atmVcPerformance 2 }
|
|
|
|
atmVcPMCurrentEntry OBJECT-TYPE
|
|
SYNTAX AtmVcPMCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VC Current table for Performance
|
|
Management."
|
|
INDEX { ifIndex, atmVcPMCurrentVpi,
|
|
atmVcPMCurrentVci, atmVcPMCurrentDir }
|
|
::= { atmVcPMCurrentTable 1 }
|
|
|
|
AtmVcPMCurrentEntry ::=
|
|
SEQUENCE {
|
|
atmVcPMCurrentVpi
|
|
Integer32,
|
|
atmVcPMCurrentVci
|
|
Integer32,
|
|
atmVcPMCurrentDir
|
|
Integer32,
|
|
atmVcPMCurrentTxClp01
|
|
Gauge32,
|
|
atmVcPMCurrentTxClp0
|
|
Gauge32,
|
|
atmVcPMCurrentRxClp01
|
|
Gauge32,
|
|
atmVcPMCurrentRxClp0
|
|
Gauge32,
|
|
atmVcPMCurrentErroredCells
|
|
Gauge32,
|
|
atmVcPMCurrentLostCells
|
|
Gauge32,
|
|
atmVcPMCurrentMisinsertedCells
|
|
Gauge32,
|
|
atmVcPMCurrentECB
|
|
Gauge32,
|
|
atmVcPMCurrentSECB
|
|
Gauge32,
|
|
atmVcPMCurrentES
|
|
Gauge32,
|
|
atmVcPMCurrentSES
|
|
Gauge32,
|
|
atmVcPMCurrentUAS
|
|
Gauge32,
|
|
atmVcPMCurrentIntervalQuality
|
|
INTEGER,
|
|
atmVcPMCurrentLastDayQuality
|
|
INTEGER
|
|
}
|
|
|
|
atmVcPMCurrentVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VCL."
|
|
::= { atmVcPMCurrentEntry 1 }
|
|
|
|
atmVcPMCurrentVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the VCL."
|
|
::= { atmVcPMCurrentEntry 2 }
|
|
|
|
atmVcPMCurrentDir OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of Performance Management."
|
|
::= { atmVcPMCurrentEntry 3 }
|
|
|
|
atmVcPMCurrentTxClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
CLP 0+1 cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 4 }
|
|
|
|
atmVcPMCurrentTxClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
CLP 0 cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 5 }
|
|
|
|
atmVcPMCurrentRxClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
CLP 0+1 cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 6 }
|
|
|
|
atmVcPMCurrentRxClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
CLP 0 cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 7 }
|
|
|
|
atmVcPMCurrentErroredCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of errored
|
|
cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 8 }
|
|
|
|
atmVcPMCurrentLostCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of lost
|
|
cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 9 }
|
|
|
|
atmVcPMCurrentMisinsertedCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of misinserted
|
|
cells, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 10 }
|
|
|
|
atmVcPMCurrentECB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of ECBs
|
|
encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 11 }
|
|
|
|
atmVcPMCurrentSECB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SECBs
|
|
encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 12 }
|
|
|
|
atmVcPMCurrentES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
Errored Seconds, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 13 }
|
|
|
|
atmVcPMCurrentSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severely
|
|
Errored Seconds, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 14 }
|
|
|
|
atmVcPMCurrentUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severely
|
|
Errored Seconds, encountered by the VCL of this ATM
|
|
interface in the current 15 minute interval."
|
|
::= { atmVcPMCurrentEntry 15 }
|
|
|
|
atmVcPMCurrentIntervalQuality OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(2), unacceptable(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the number of errors per interval is superior to
|
|
the atmNteUPLTCR value, the quality of service of
|
|
the interval is declared as unacceptable."
|
|
DEFVAL { normal }
|
|
::= { atmVcPMCurrentEntry 16 }
|
|
|
|
atmVcPMCurrentLastDayQuality OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(2), degraded(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the number of errors per 24 hours is superior to
|
|
the atmNteDPLTCR value, the quality of service of
|
|
the day is declared as degraded."
|
|
DEFVAL { normal }
|
|
::= { atmVcPMCurrentEntry 17 }
|
|
|
|
|
|
-- the ATM VC Interval
|
|
|
|
-- The ATM VC Interval Table contains various statistics
|
|
-- collected by each ATM Interface/VC over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
atmVcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM Vc Interval table."
|
|
::= { atmVcPerformance 3 }
|
|
|
|
atmVcIntervalEntry OBJECT-TYPE
|
|
SYNTAX AtmVcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM Vc Interval table."
|
|
INDEX { ifIndex, atmVcIntervalVpi,
|
|
atmVcIntervalVci, atmVcIntervalNumber }
|
|
::= { atmVcIntervalTable 1 }
|
|
|
|
AtmVcIntervalEntry ::=
|
|
SEQUENCE {
|
|
atmVcIntervalVpi
|
|
Integer32,
|
|
atmVcIntervalVci
|
|
Integer32,
|
|
atmVcIntervalNumber
|
|
Integer32,
|
|
atmVcIntervalRxCellsClp01
|
|
Gauge32,
|
|
atmVcIntervalRxCellsClp0
|
|
Gauge32,
|
|
atmVcIntervalGcra0Violations
|
|
Gauge32,
|
|
atmVcIntervalGcra1Violations
|
|
Gauge32,
|
|
atmVcIntervalRxAIS
|
|
Gauge32,
|
|
atmVcIntervalTxAIS
|
|
Gauge32,
|
|
atmVcIntervalRxRDI
|
|
Gauge32,
|
|
atmVcIntervalTxRDI
|
|
Gauge32,
|
|
atmVcIntervalContinuityLoss
|
|
Gauge32,
|
|
atmVcIntervalUAS
|
|
Gauge32,
|
|
atmVcIntervalSES
|
|
Gauge32,
|
|
atmVcIntervalCDC
|
|
Gauge32,
|
|
atmVcIntervalTotalDiscards
|
|
Gauge32,
|
|
atmVcIntervalClp0Discards
|
|
Gauge32,
|
|
atmVcIntervalTotalCellOuts
|
|
Gauge32,
|
|
atmVcIntervalClp0CellOuts
|
|
Gauge32,
|
|
atmVcIntervalTaggedOuts
|
|
Gauge32,
|
|
atmVcIntervalPCR
|
|
Gauge32,
|
|
atmVcIntervalSCR
|
|
Gauge32,
|
|
atmVcIntervalMCR
|
|
Gauge32,
|
|
atmVcIntervalShaperTotalDiscards
|
|
Gauge32,
|
|
atmVcIntervalShaperClp0Discards
|
|
Gauge32,
|
|
atmVcIntervalShaperClp1Discards
|
|
Gauge32
|
|
}
|
|
|
|
atmVcIntervalVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VCL."
|
|
::= { atmVcIntervalEntry 1 }
|
|
|
|
atmVcIntervalVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the VCL."
|
|
::= { atmVcIntervalEntry 2 }
|
|
|
|
atmVcIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { atmVcIntervalEntry 3 }
|
|
|
|
atmVcIntervalRxCellsClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
cells , encountered by an ATM interface/VC in
|
|
one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { atmVcIntervalEntry 4 }
|
|
|
|
atmVcIntervalRxCellsClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 5 }
|
|
|
|
atmVcIntervalGcra0Violations OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
cells violating GCRA0, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 6 }
|
|
|
|
atmVcIntervalGcra1Violations OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
cells violating GCRA1, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 7 }
|
|
|
|
atmVcIntervalRxAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
AIS cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 8 }
|
|
|
|
atmVcIntervalTxAIS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
AIS cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals. Not supported in the first phase."
|
|
::= { atmVcIntervalEntry 9 }
|
|
|
|
atmVcIntervalRxRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
RDI cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 10 }
|
|
|
|
atmVcIntervalTxRDI OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
RDI cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 11 }
|
|
|
|
atmVcIntervalContinuityLoss OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Continuity
|
|
Loss cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 12 }
|
|
|
|
atmVcIntervalUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Unavailable
|
|
Seconds, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 13 }
|
|
|
|
atmVcIntervalSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severerly Errored
|
|
Seconds, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcIntervalEntry 14 }
|
|
|
|
atmVcIntervalCDC OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of cells dropped in the 15 minute interval
|
|
of the VC connection."
|
|
::= { atmVcIntervalEntry 15 }
|
|
|
|
atmVcIntervalTotalDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells discarded by
|
|
the traffic policing entity. This includes cells
|
|
originally received with CLP=0 and CLP=1."
|
|
::= { atmVcIntervalEntry 16 }
|
|
|
|
atmVcIntervalClp0Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells received with
|
|
CLP=0 an discarded by the traffic policing
|
|
entity."
|
|
::= { atmVcIntervalEntry 17 }
|
|
|
|
atmVcIntervalTotalCellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells transmitted
|
|
by this VPL. This includes both CLP=0 and CLP=1
|
|
cells."
|
|
::= { atmVcIntervalEntry 18 }
|
|
|
|
|
|
atmVcIntervalClp0CellOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells transmitted
|
|
with CLP=0 by this VPL."
|
|
::= { atmVcIntervalEntry 19 }
|
|
|
|
atmVcIntervalTaggedOuts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of valid ATM cells tagged by the
|
|
traffic policing entity from CLP=0 to CLP=1 and
|
|
transmitted by this VPL."
|
|
::= { atmVcIntervalEntry 20 }
|
|
|
|
atmVcIntervalPCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum traffic rate encountered in the
|
|
last interval of the VC connection (monitored once a second)
|
|
encountered by an ATM interface/VC in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { atmVcIntervalEntry 21 }
|
|
|
|
atmVcIntervalSCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average traffic rate during the last interval
|
|
of the VC connection, encountered by an ATM interface/VC
|
|
in one of the previous 96, individual 15 minute, intervals."
|
|
::= { atmVcIntervalEntry 22 }
|
|
|
|
atmVcIntervalMCR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MCR - The minimum traffic rate encountered in the last
|
|
interval of the VC connection (monitored once a second)
|
|
encountered by an ATM interface/VC in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { atmVcIntervalEntry 23 }
|
|
|
|
atmVcIntervalShaperTotalDiscards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of cells (CLP0 and CLP1) discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVcIntervalEntry 24 }
|
|
|
|
atmVcIntervalShaperClp0Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of CLP0 cells discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVcIntervalEntry 25 }
|
|
|
|
atmVcIntervalShaperClp1Discards OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of CLP1 cells discarded
|
|
due to congestion by the traffic shaper."
|
|
::= { atmVcIntervalEntry 26 }
|
|
|
|
|
|
-- The ATM VC Interval Table for Performance Management
|
|
-- which contains various statistics
|
|
-- collected by each ATM Interface/VC over the previous 24
|
|
-- hours of operation. The past 24 hours are broken into 96
|
|
-- completed 15 minute intervals.
|
|
|
|
atmVcPMIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcPMIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM Vc Interval table for Performance Management."
|
|
::= { atmVcPerformance 4 }
|
|
|
|
--atmCESAAL1StatsTable OBJECT IDENTIFIER ::= {atmVcPerformance 5} (see hybCES.txt)
|
|
|
|
atmVcPMIntervalEntry OBJECT-TYPE
|
|
SYNTAX AtmVcPMIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM Vc Interval table for Performance
|
|
Management."
|
|
INDEX { ifIndex, atmVcPMIntervalVpi,
|
|
atmVcPMIntervalVci, atmVcPMIntervalDir, atmVcPMIntervalNumber }
|
|
::= { atmVcPMIntervalTable 1 }
|
|
|
|
AtmVcPMIntervalEntry ::=
|
|
SEQUENCE {
|
|
atmVcPMIntervalVpi
|
|
Integer32,
|
|
atmVcPMIntervalVci
|
|
Integer32,
|
|
atmVcPMIntervalDir
|
|
INTEGER,
|
|
atmVcPMIntervalNumber
|
|
Integer32,
|
|
atmVcPMIntervalTxClp01
|
|
Gauge32,
|
|
atmVcPMIntervalTxClp0
|
|
Gauge32,
|
|
atmVcPMIntervalRxClp01
|
|
Gauge32,
|
|
atmVcPMIntervalRxClp0
|
|
Gauge32,
|
|
atmVcPMIntervalErroredCells
|
|
Gauge32,
|
|
atmVcPMIntervalLostCells
|
|
Gauge32,
|
|
atmVcPMIntervalMisinsertedCells
|
|
Gauge32,
|
|
atmVcPMIntervalECB
|
|
Gauge32,
|
|
atmVcPMIntervalSECB
|
|
Gauge32,
|
|
atmVcPMIntervalES
|
|
Gauge32,
|
|
atmVcPMIntervalSES
|
|
Gauge32,
|
|
atmVcPMIntervalUAS
|
|
Gauge32,
|
|
atmVcPMIntervalQuality
|
|
INTEGER,
|
|
atmVcPMIntervalLastDayQuality
|
|
INTEGER
|
|
}
|
|
|
|
atmVcPMIntervalVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the VCL."
|
|
::= { atmVcPMIntervalEntry 1 }
|
|
|
|
atmVcPMIntervalVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the VCL."
|
|
::= { atmVcPMIntervalEntry 2 }
|
|
|
|
atmVcPMIntervalDir OBJECT-TYPE
|
|
SYNTAX INTEGER {forward(2),
|
|
backward(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of Performance Management."
|
|
::= { atmVcPMIntervalEntry 3 }
|
|
|
|
atmVcPMIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { atmVcPMIntervalEntry 4 }
|
|
|
|
atmVcPMIntervalTxClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
CLP 0+1 cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 5 }
|
|
|
|
atmVcPMIntervalTxClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted
|
|
CLP 0 cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 6 }
|
|
|
|
atmVcPMIntervalRxClp01 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
CLP 0+1 cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 7 }
|
|
|
|
atmVcPMIntervalRxClp0 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received
|
|
CLP 0 cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 8 }
|
|
|
|
atmVcPMIntervalErroredCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Errored
|
|
cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 9 }
|
|
|
|
atmVcPMIntervalLostCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Lost
|
|
cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 10 }
|
|
|
|
atmVcPMIntervalMisinsertedCells OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Misinserted
|
|
cells, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 11 }
|
|
|
|
atmVcPMIntervalECB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of ECBs
|
|
encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 12 }
|
|
|
|
atmVcPMIntervalSECB OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of SECBs
|
|
encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 13 }
|
|
|
|
atmVcPMIntervalES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Errored
|
|
Seconds, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 14 }
|
|
|
|
atmVcPMIntervalSES OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Severely
|
|
Errored Seconds, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 15 }
|
|
|
|
atmVcPMIntervalUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Unavailable
|
|
Seconds, encountered by an ATM
|
|
interface/VC in one of the previous 96, individual 15
|
|
minute, intervals."
|
|
::= { atmVcPMIntervalEntry 16 }
|
|
|
|
atmVcPMIntervalQuality OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(2), unacceptable(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the number of errors per interval is superior to
|
|
the atmNteUPLTCR value, the quality of service of
|
|
the interval is declared as unacceptable."
|
|
DEFVAL { normal }
|
|
::= { atmVcPMIntervalEntry 17}
|
|
|
|
atmVcPMIntervalLastDayQuality OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(2), degraded(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the number of errors per 24 hours is superior to
|
|
the atmNteDPLTCR value, the quality of service of
|
|
the day is declared as degraded."
|
|
DEFVAL { normal }
|
|
::= { atmVcPMIntervalEntry 18}
|
|
|
|
|
|
|
|
|
|
-- VC QoS Table
|
|
|
|
atmVcQoSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcQoSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VP QoS table."
|
|
::= { atmVcPerformance 6 }
|
|
|
|
atmVcQoSEntry OBJECT-TYPE
|
|
SYNTAX AtmVcQoSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VP table."
|
|
INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcQoSPeriodRef }
|
|
::= { atmVcQoSTable 1 }
|
|
|
|
AtmVcQoSEntry ::=
|
|
SEQUENCE {
|
|
atmVcQoSPeriodRef INTEGER,
|
|
atmVcQoSElapsedTime Integer32,
|
|
atmVcQoSUAS Gauge32
|
|
}
|
|
|
|
|
|
atmVcQoSPeriodRef OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
currentPeriod (1),
|
|
lastPeriod (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index that specifies which period of time, the next
|
|
2 objects refer to.
|
|
currentPeriod - the period since last systemResetAllStatsCmd received or
|
|
since Start-up (if no systemResetAllStatsCmd was received since
|
|
Start-up) until now.
|
|
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
|
|
- If only one command occurred since Start-up: the period between
|
|
Start-up and last command.
|
|
- If no command occurred since Start-up: this period will not
|
|
actually exist. In this case, he following 5 objects will be 0."
|
|
::= { atmVcQoSEntry 1 }
|
|
|
|
atmVcQoSElapsedTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Elapsed Time in seconds.
|
|
- for atmVcQoSPeriodRef = currentPeriod:
|
|
The period since last systemResetAllStatsCmd received or since Start-up
|
|
(if no systemResetAllStatsCmd was received since Start-up) until now.
|
|
- for atmVcQoSPeriodRef = lastPeriod:
|
|
The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd
|
|
was received."
|
|
::= { atmVcQoSEntry 2 }
|
|
|
|
atmVcQoSUAS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef)."
|
|
::= { atmVcQoSEntry 3 }
|
|
|
|
-- VC PM QoS Table
|
|
|
|
atmVcPMQoSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcPMQoSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PM VC QoS table."
|
|
::= { atmVcPerformance 7 }
|
|
|
|
atmVcPMQoSEntry OBJECT-TYPE
|
|
SYNTAX AtmVcPMQoSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the VC PM QoS table."
|
|
INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcPMQoSDirection ,atmVcPMQoSPeriodRef }
|
|
::= { atmVcPMQoSTable 1 }
|
|
|
|
AtmVcPMQoSEntry ::=
|
|
SEQUENCE {
|
|
atmVcPMQoSDirection INTEGER,
|
|
atmVcPMQoSPeriodRef INTEGER,
|
|
atmVcPMQoSCLR Gauge32,
|
|
atmVcPMQoSCER Gauge32,
|
|
atmVcPMQoSCMR Gauge32
|
|
}
|
|
|
|
atmVcPMQoSDirection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
forward(2),
|
|
backward(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of performance management."
|
|
::= { atmVcPMQoSEntry 1 }
|
|
|
|
atmVcPMQoSPeriodRef OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
currentPeriod (1),
|
|
lastPeriod (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an index that specifies which period of time, the next
|
|
5 objects refer to.
|
|
currentPeriod - the period since last systemResetAllStatsCmd received or
|
|
since Start-up (if no systemResetAllStatsCmd was received since
|
|
Start-up) until now.
|
|
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
|
|
- If only one command occurred since Start-up: the period between
|
|
Start-up and last command.
|
|
- If no command occurred since Start-up: this period will not
|
|
actually exist. In this case, he following 5 objects will be 0."
|
|
::= { atmVcPMQoSEntry 2 }
|
|
|
|
|
|
atmVcPMQoSCLR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)-
|
|
defined in accordance with I.356 , in %.
|
|
The value will be multipuled by 100."
|
|
::= { atmVcPMQoSEntry 3 }
|
|
|
|
atmVcPMQoSCER OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef)
|
|
defined in accordance with I.356 , in %.
|
|
The value will be multipuled by 100."
|
|
::= { atmVcPMQoSEntry 4 }
|
|
|
|
atmVcPMQoSCMR OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef)
|
|
defined in accordance with I.356 , cells/sec ."
|
|
::= { atmVcPMQoSEntry 5 }
|
|
|
|
--VC Shaper Statistics Table
|
|
atmVcShaperStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcShaperStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VC shaper statistics table."
|
|
::= { atmVcPerformance 8 }
|
|
|
|
atmVcShaperStatEntry OBJECT-TYPE
|
|
SYNTAX AtmVcShaperStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ATM VC shaper statistics table."
|
|
INDEX { ifIndex, atmVclVpi, atmVclVci }
|
|
::= { atmVcShaperStatTable 1 }
|
|
|
|
AtmVcShaperStatEntry ::=
|
|
SEQUENCE {
|
|
atmVcShaperDiscarded Counter32,
|
|
atmVcShaperOccupation Integer32,
|
|
atmVcShaperMaxOccupation Integer32,
|
|
atmVcShaperLevel INTEGER,
|
|
atmVcShaperEpdDropped Counter32,
|
|
atmVcShaperTotalEpdDropped Counter32
|
|
}
|
|
|
|
atmVcShaperDiscarded OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Cells that were discarded in the shaper on that VCC due
|
|
to buffer overflow. This counter counts till it reaches its MAX value
|
|
(20 bits) and then rolls over."
|
|
::= { atmVcShaperStatEntry 1 }
|
|
|
|
atmVcShaperOccupation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Cells that are currently stored in the buffer.
|
|
This parameter is limited to 20 bits."
|
|
::= { atmVcShaperStatEntry 2}
|
|
|
|
atmVcShaperMaxOccupation OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Maximum number of Cells that were stored in the buffer,
|
|
since this VC was activated. This parameter is limited to 20 bits."
|
|
::= { atmVcShaperStatEntry 3}
|
|
|
|
atmVcShaperLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
empty (1),
|
|
full (2),
|
|
below (3),
|
|
above (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The occupation of the buffer according to a predefined threshold.
|
|
empty - buffer is Empty
|
|
full - buffer is Full
|
|
below - buffer is Below the threshold
|
|
above - buffer is Above the threshold. This is also the trigger to
|
|
start EPD\PPD mechanism, if set for the VCC."
|
|
::= { atmVcShaperStatEntry 4}
|
|
|
|
atmVcShaperEpdDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Cells that were dropped in the shaper on that VCC
|
|
due to EPD\PPD mechanism in the last second.
|
|
This parameter is limited to 24 bits.
|
|
Applicable for a EPD/PPD VC only."
|
|
::= { atmVcShaperStatEntry 5}
|
|
|
|
atmVcShaperTotalEpdDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Total number of Cells that were dropped in the shaper on that
|
|
VPC due to EPD\PPD mechanism in the last 15 minutes. This counter
|
|
automatically reset itself every 15 minutes.
|
|
Applicable for a EPD/PPD VC only."
|
|
::= { atmVcShaperStatEntry 6}
|
|
|
|
|
|
|
|
-- New
|
|
-- The agent will keep in this group the date & time corresponding to each interval.
|
|
atmIntervalDateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmIntervalDateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The agent will keep in this group the date & time
|
|
corresponding to each interval."
|
|
::= {atmPerfHistory 3}
|
|
|
|
atmIntervalDateEntry OBJECT-TYPE
|
|
SYNTAX AtmIntervalDateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date & time for the given interval."
|
|
INDEX { atmIntervalDateInterval }
|
|
::= { atmIntervalDateTable 1 }
|
|
|
|
AtmIntervalDateEntry ::=
|
|
SEQUENCE {
|
|
atmIntervalDateInterval
|
|
Integer32,
|
|
atmIntervalDateDate
|
|
DisplayString,
|
|
atmIntervalDateTime
|
|
DisplayString
|
|
}
|
|
|
|
atmIntervalDateInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The interval number defining this entry."
|
|
::= { atmIntervalDateEntry 1}
|
|
|
|
atmIntervalDateDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date corresponding to this interval."
|
|
::= { atmIntervalDateEntry 2}
|
|
|
|
atmIntervalDateTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time corresponding to this interval."
|
|
::= { atmIntervalDateEntry 3}
|
|
|
|
|
|
|
|
--atmNte OBJECT IDENTIFIER ::= {radAtm 3}
|
|
|
|
atmNteSys OBJECT IDENTIFIER ::= {atmNte 1}
|
|
|
|
atmNteSysConfig OBJECT IDENTIFIER ::= {atmNteSys 1}
|
|
|
|
atmNteManagerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteManagerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Manager Table includes all the NMSs that
|
|
receive traps from this agent. A single manager
|
|
can receive traps on more than one PVC. The agent
|
|
will set implicitly the correct ifIndex, VPI, VCI
|
|
values to all relevant entries in the table when
|
|
the user changes them for one of the PVCs."
|
|
::= { atmNteSysConfig 1 }
|
|
|
|
atmNteManagerEntry OBJECT-TYPE
|
|
SYNTAX AtmNteManagerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A single manager and the PVC for receiving traps."
|
|
INDEX { atmNteManagerIP, atmNteManagerPvc}
|
|
::= { atmNteManagerTable 1 }
|
|
|
|
AtmNteManagerEntry ::=
|
|
SEQUENCE {
|
|
atmNteManagerIP
|
|
IpAddress,
|
|
atmNteManagerPvc
|
|
Integer32,
|
|
atmNteManagerIfIndex
|
|
Integer32,
|
|
atmNteManagerVpi
|
|
Integer32,
|
|
atmNteManagerVci
|
|
Integer32,
|
|
atmNteManagerTrapMask
|
|
Integer32,
|
|
atmNteManagerRowStatus
|
|
RowStatus,
|
|
atmNteManagerNextHop
|
|
IpAddress,
|
|
atmNteManagerVlanSupport
|
|
INTEGER,
|
|
atmNteManagerVlanIdentifier
|
|
Integer32,
|
|
atmNteManagerVlanFramePriority
|
|
Integer32,
|
|
atmNteManagerAlarmTrapMask
|
|
OCTET STRING,
|
|
atmNteManagerConfigPorts
|
|
Integer32
|
|
}
|
|
|
|
atmNteManagerIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of the NMS."
|
|
::= { atmNteManagerEntry 1 }
|
|
|
|
atmNteManagerPvc OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A PVC index. The range is 1..8. There are four PVCs
|
|
on the User Port and four PVCs on the Network Port.
|
|
The default VPI, VCI values are specified below."
|
|
::= { atmNteManagerEntry 2 }
|
|
|
|
atmNteManagerIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM interface index of the management port."
|
|
::= { atmNteManagerEntry 3 }
|
|
|
|
atmNteManagerVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the management VCL. Default: 0."
|
|
::= { atmNteManagerEntry 4 }
|
|
|
|
atmNteManagerVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the management VCL. Defaults: 32,33,34,35."
|
|
::= { atmNteManagerEntry 5 }
|
|
|
|
atmNteManagerTrapMask OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this attribute determines the type of traps the
|
|
agent should mask and not send to this NMS. The
|
|
value is differently determined for different products. There are
|
|
mainly two methods:
|
|
- an integer number, specifying the traps' severity.
|
|
- a sum of 2**n, where n is a bit assigned to a certain
|
|
masked trap group.
|
|
User should consult the product specification, to find out
|
|
the method employed."
|
|
::= { atmNteManagerEntry 6 }
|
|
|
|
atmNteManagerRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= {atmNteManagerEntry 7}
|
|
|
|
atmNteManagerNextHop OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is relevant to Ethernet out of band
|
|
host only (PVC=10).
|
|
The Next Hop IP address of the entry route."
|
|
::= { atmNteManagerEntry 8 }
|
|
|
|
atmNteManagerVlanSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN support (Tagging).
|
|
no - No support to VLAN.
|
|
yes - 4 VLAN bytes will be added to the frame."
|
|
::= { atmNteManagerEntry 9}
|
|
|
|
atmNteManagerVlanIdentifier OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID. Range is 0..4095."
|
|
::= { atmNteManagerEntry 10 }
|
|
|
|
atmNteManagerVlanFramePriority OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN Frame priority.Range is 0..7."
|
|
::= { atmNteManagerEntry 11 }
|
|
|
|
atmNteManagerAlarmTrapMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object determines the alarm traps that the
|
|
agent should mask and not send to this NMS.
|
|
|
|
The value is an Octet String, where each bit is assigned to a certain
|
|
trap.
|
|
If the bit = 1, the trap will be masked.
|
|
If the bit = 0, the trap will not be masked.
|
|
More details on the masked traps exist in the product specification.
|
|
|
|
For products that do not mask specific traps, the value of the bits will be 0."
|
|
::= { atmNteManagerEntry 12 }
|
|
|
|
atmNteManagerConfigPorts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable defines from which port/s this manager can configure the device.
|
|
For IPmux 11 the value of this variable will be according to the ports
|
|
combination:
|
|
Network =1
|
|
User1=2
|
|
User2=4
|
|
(For Example: All ports = 7)."
|
|
::= { atmNteManagerEntry 13 }
|
|
|
|
|
|
|
|
atmNteUPLTCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Unacceptable ES Limit threshold for Performance Management."
|
|
::= {atmNteSysConfig 2}
|
|
|
|
atmNteDPLTCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Degraded ES Limit threshold for Performance Management."
|
|
::= {atmNteSysConfig 3}
|
|
|
|
atmNteSysLogClearAll OBJECT-TYPE
|
|
SYNTAX INTEGER { off(2), clear(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the variable to clear(3) removes all entries in the
|
|
Log Buffer of the agent. The agent will immediately reset
|
|
the variable to off(2)."
|
|
::= {atmNteSysConfig 4}
|
|
|
|
atmNteUSESLTCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Unacceptable SES Limit threshold for Performance Management."
|
|
::= {atmNteSysConfig 5}
|
|
|
|
atmNteDSESLTCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Degraded ES Limit threshold for Performance Management."
|
|
::= {atmNteSysConfig 6}
|
|
|
|
|
|
atmNteProtection OBJECT IDENTIFIER ::= { atmNteSysConfig 8 }
|
|
|
|
atmNteProtectionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
mspOn (2),
|
|
pathOn (3),
|
|
mspUniOn (4),
|
|
mspOneToN (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Protection Mode.
|
|
MspOn - Multiplex section protection.
|
|
pathOn - High order path protection.
|
|
mspUniOn - Multiplex section Uni-directional protection.
|
|
mspOneToN - Multiplex section protection."
|
|
::= { atmNteProtection 1 }
|
|
|
|
atmNteProtectionWorkingLink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
trunk1(2),
|
|
trunk2(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects the working link when atmNteProtectionMode is off."
|
|
::= { atmNteProtection 2 }
|
|
|
|
atmNteProtectionSwitchLink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
forceSwitch(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ForceSwitch - will force Switching from the working link to the backup link.
|
|
Afterwards the agent will set atmNteProtectionSwitchLink back to off(1).
|
|
atmNteProtectionMode must be either mspOn or pathOn."
|
|
::= { atmNteProtection 3 }
|
|
|
|
atmNteConfOam OBJECT IDENTIFIER ::= { atmNteSysConfig 9 }
|
|
|
|
atmNteConfOamSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
intermediate(1),
|
|
segmentTermination(2),
|
|
endToEndTermination(3),
|
|
vpEndToEndVcSegment(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM support mode, which determines the device location
|
|
in a segment wise."
|
|
::= { atmNteConfOam 1 }
|
|
|
|
atmNteConfOamTransmission OBJECT IDENTIFIER ::= { atmNteConfOam 2 }
|
|
|
|
atmNteConfOamAIS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
user(2),
|
|
network(3),
|
|
both(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines if a F4 segment OAM cell is transmitted due
|
|
to problems in the other port, i.e. physical layer
|
|
alarm or F4 defect. This is valid only when the ACE101
|
|
has ATM UNI interfaces in both sides and is configured
|
|
for 'Non-Intrusive' mode.
|
|
none - AIS is not sent to any of the ports.
|
|
user - F4 AIS will be sent toward the user when defect
|
|
is detected in the network port.
|
|
network - F4 AIS will be sent toward the network when
|
|
defect is detected in the user port.
|
|
both - F4 AIS will be sent toward the network when defect
|
|
is detected in the user port and toward the user
|
|
when defect is detected in the network port."
|
|
::= { atmNteConfOamTransmission 1 }
|
|
|
|
atmNteConfOamRDI OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
user(2),
|
|
network(3),
|
|
both(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines if an F4 OAM RDI cell is transmitted due to
|
|
physical layer problems in the port (in addition to
|
|
F4 RDI cells transmitted due to ATM layer problems).
|
|
The type of F4 RDI (Segment or End-to-End) is according
|
|
to the ACE-101 OAM mode.
|
|
For example, If it is enabled for Network port, then
|
|
physical layer defect will initiate the transmission
|
|
of F4 RDI cell back to the trunk."
|
|
::= { atmNteConfOamTransmission 2 }
|
|
|
|
atmNteConfOamAddressing OBJECT IDENTIFIER ::= { atmNteConfOam 3 }
|
|
|
|
atmNteConfLoopbackAddMode OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
off(1),
|
|
on(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loopback addressing mode.
|
|
on - will enable loopback addressing.
|
|
off - will disable loopback addressing."
|
|
::= { atmNteConfOamAddressing 1 }
|
|
|
|
atmNteConfLoopbackSourceAdd OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Loopback source address. This field is relevant when
|
|
atmNteConfOamAddMode is on."
|
|
::= { atmNteConfOamAddressing 2 }
|
|
|
|
--OAM Table
|
|
atmNteConfOamIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteConfOamIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OAM support per ATM interface."
|
|
::= { atmNteConfOam 4 }
|
|
|
|
atmNteConfOamIfEntry OBJECT-TYPE
|
|
SYNTAX AtmNteConfOamIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
INDEX { ifIndex }
|
|
::= { atmNteConfOamIfTable 1 }
|
|
|
|
AtmNteConfOamIfEntry ::=
|
|
SEQUENCE {
|
|
atmNteConfOamIfAisRdi INTEGER
|
|
}
|
|
|
|
atmNteConfOamIfAisRdi OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter controls the generation of F4/F5
|
|
AIS and RDI due to lower order problems such as physical
|
|
layer problems.
|
|
|
|
For AIS: Defines if F4/F5 AIS cell is transmitted due
|
|
to problems such as physical layer alarm or F4/F5 defect.
|
|
This is applicable for all ports .
|
|
off - Problems in this port will not trigger F4/F5 AIS
|
|
transmition to the ajacent port (e.g. from USER to
|
|
NETWORK) of a VPC/VCC.
|
|
on - Problems in this port will trigger F4/F5 AIS
|
|
transmition to the ajacent port (e.g. from USER
|
|
to NETWORK) of a VPC/VCC.
|
|
|
|
For RDI: Defines if F4/F5 RDI cell will be transmitted due to
|
|
physical layer problems in that port (in addition to
|
|
F4/F5 RDI cells transmitted due to ATM layer problems).
|
|
For example, If it is enabled for Network port, then
|
|
physical layer defect will initiate the transmission
|
|
of F4/F5 RDI cell back to the trunk.
|
|
|
|
The type of F4/F5 (Segment or End-to-End) is according
|
|
to the configuration of the VPC/VCC."
|
|
::= { atmNteConfOamIfEntry 1 }
|
|
|
|
|
|
atmNteConfCAC OBJECT IDENTIFIER ::= { atmNteSysConfig 10 }
|
|
|
|
atmNteConfCACMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CAC support mode.
|
|
|
|
For ACE2002, the following are the applicable values:
|
|
disable(1), enable(2), 10 - 1000."
|
|
::= { atmNteConfCAC 1 }
|
|
|
|
atmNteHostIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteHostIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Host IP interface table."
|
|
::= { atmNteSysConfig 11 }
|
|
|
|
atmNteHostIfEntry OBJECT-TYPE
|
|
SYNTAX AtmNteHostIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
INDEX { atmNteHostPvcIndex }
|
|
::= { atmNteHostIfTable 1 }
|
|
|
|
AtmNteHostIfEntry ::=
|
|
SEQUENCE {
|
|
atmNteHostPvcIndex
|
|
Integer32,
|
|
atmNteHostIP
|
|
IpAddress,
|
|
atmNteHostMask
|
|
IpAddress,
|
|
atmNteHostAtmIfIndex
|
|
Integer32,
|
|
atmNteHostVpi
|
|
Integer32,
|
|
atmNteHostVci
|
|
Integer32,
|
|
atmNteHostRowStatus
|
|
RowStatus,
|
|
atmNteHostRdnVpi
|
|
Integer32,
|
|
atmNteHostRdnVci
|
|
Integer32,
|
|
atmNteHostDefaultNextHop
|
|
IpAddress,
|
|
atmNteHostVlanTagging
|
|
INTEGER,
|
|
atmNteHostDefaultVlanID
|
|
Integer32,
|
|
atmNteHostDefaultVlanPriority
|
|
Integer32
|
|
}
|
|
|
|
|
|
atmNteHostPvcIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A PVC index. The range is 1..10."
|
|
::= { atmNteHostIfEntry 1 }
|
|
|
|
atmNteHostIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The host interface IP address."
|
|
::= { atmNteHostIfEntry 2 }
|
|
|
|
atmNteHostMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The host interface subnet mask."
|
|
::= { atmNteHostIfEntry 3 }
|
|
|
|
atmNteHostAtmIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ATM interface index. Will be 1
|
|
for user port, and 2 for network port."
|
|
::= { atmNteHostIfEntry 4 }
|
|
|
|
atmNteHostVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VPI of the PVC connected to that host interface."
|
|
::= { atmNteHostIfEntry 5 }
|
|
|
|
atmNteHostVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VCI of the PVC connected to that host interface."
|
|
::= { atmNteHostIfEntry 6 }
|
|
|
|
atmNteHostRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= { atmNteHostIfEntry 7 }
|
|
|
|
atmNteHostRdnVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the redundant management VCL.
|
|
This parameter is applicable only if atmNteRdnManagement=enable(3). "
|
|
::= { atmNteHostIfEntry 8 }
|
|
|
|
atmNteHostRdnVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the redundant management VCL.
|
|
This parameter is applicable only if atmNteRdnManagement=enable(3). "
|
|
::= { atmNteHostIfEntry 9 }
|
|
|
|
atmNteHostDefaultNextHop OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The host interface Default Next Hop address.
|
|
This address will be used as default next hop for
|
|
every Bundle mapped to this Host."
|
|
::= { atmNteHostIfEntry 10 }
|
|
|
|
atmNteHostVlanTagging OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN Tag support.
|
|
no - No support to VLAN.
|
|
yes - 4 VLAN bytes will be added
|
|
to each frame connected to this Host."
|
|
::= { atmNteHostIfEntry 11 }
|
|
|
|
atmNteHostDefaultVlanID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default VLAN ID of this Host."
|
|
::= { atmNteHostIfEntry 12 }
|
|
|
|
atmNteHostDefaultVlanPriority OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default VLAN priority for this Host."
|
|
::= { atmNteHostIfEntry 13 }
|
|
|
|
|
|
atmNteShaperMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
group (2),
|
|
aggregate (3),
|
|
vpInbandMng (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shaper Mode.
|
|
vpInbandMng - Vcc within a Vp for management."
|
|
::= { atmNteSysConfig 12 }
|
|
|
|
|
|
atmNteOutputRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Aggregate shaping output rate in Cells per Seconds units.
|
|
Default value is the Network port rate."
|
|
::= { atmNteSysConfig 13 }
|
|
|
|
atmNteTosMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TOS Mode."
|
|
::= { atmNteSysConfig 14 }
|
|
|
|
atmNteTosMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the seqence of bits that will be used for TOS.
|
|
For ACE101 this parameter is applicable only if atmNteTosMode = enable.
|
|
Valid only for IP-TOS process."
|
|
::= { atmNteSysConfig 15 }
|
|
|
|
atmNteTosHighPriority OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Priorities options are High or Low.
|
|
High priority will be represented by bit = 1.
|
|
Low priority will be represented by bit = 0.
|
|
Each TOS value will be represented by the bit location.
|
|
For example, the string for TOS 2, 9, 15 with High priority,
|
|
will be:
|
|
|
|
|0000 0000|... ...|0000 0000|1000 0010|0000 0100|
|
|
...98 7654 3210 (Bit #)
|
|
|
|
8 ... 3 2 1 (Byte #)."
|
|
::= { atmNteSysConfig 16 }
|
|
|
|
atmNtePlugAndPlayActivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
offline (2),
|
|
online (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Activity control for Manager Plug And Play.
|
|
disable - disable the feature.
|
|
offline - Automatic learn IP address into offline memory.
|
|
online - Automatic learn IP address into online memory. "
|
|
::= { atmNteSysConfig 17 }
|
|
|
|
atmNteSlotUsage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
user (2),
|
|
network (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to ace2002. Slot 2 might be configured
|
|
as user slot or as network slot."
|
|
::= { atmNteSysConfig 18 }
|
|
|
|
atmNteConnectionsMaxNumber OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
max1024 (2),
|
|
max2048 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAX number of connections supported by system.
|
|
Setting this parameter will affect the number of MAX intervals supported.
|
|
This parameter will affect the system only after reset.
|
|
Changing this parameter from high value to a low value, will be accepted by agent
|
|
only if the actual used connection <= the desired connection Max number.
|
|
Applicable to ace2002. "
|
|
::= { atmNteSysConfig 19 }
|
|
|
|
atmNteDefaultVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Vpi for management."
|
|
::= { atmNteSysConfig 20 }
|
|
|
|
atmNteDefaultVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Vci for management."
|
|
::= { atmNteSysConfig 21 }
|
|
|
|
atmNteReservedVpi OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal use VPI, where shaperMode=vpInbandMng."
|
|
::= { atmNteSysConfig 22 }
|
|
|
|
atmNteRdnManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The redundancy management status."
|
|
::= { atmNteSysConfig 23 }
|
|
|
|
atmNtePlugAndPlayIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the Plug and Play VCC."
|
|
::= { atmNteSysConfig 24 }
|
|
|
|
atmNteLoopbackTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Loopback state timeout in minutes. A value of
|
|
zero means no timeout (for ever). Default is 5 min."
|
|
::= { atmNteSysConfig 25 }
|
|
|
|
atmNteOamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteOamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is a static table, which is created by agent once
|
|
upon initialization. The created entries are actually, only the
|
|
supported OAM features.
|
|
This table enables addition of new features by adding new entries
|
|
rather than adding scalar parameters.
|
|
An OAM feature is defined by the indexes values combination."
|
|
::= { atmNteSysConfig 26 }
|
|
|
|
atmNteOamEntry OBJECT-TYPE
|
|
SYNTAX AtmNteOamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the OAM table.
|
|
Each entry in this table will indicate a special OAM."
|
|
INDEX {atmNteOamMode, atmNteOamCellType, atmNteOamLevel}
|
|
::= { atmNteOamTable 1 }
|
|
|
|
AtmNteOamEntry ::=
|
|
SEQUENCE {
|
|
atmNteOamMode
|
|
INTEGER,
|
|
atmNteOamCellType
|
|
INTEGER,
|
|
atmNteOamLevel
|
|
INTEGER,
|
|
atmNteOamEnable
|
|
INTEGER
|
|
}
|
|
|
|
atmNteOamMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
endToEnd (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OAM cell path.
|
|
endToEnd(1) - the entire path."
|
|
::= { atmNteOamEntry 1 }
|
|
|
|
atmNteOamCellType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
aisAndRdi (1),
|
|
loopback (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique Indication Signal.
|
|
aisAndRdi(1) - Alarm Indication Signal (AIS) and
|
|
Remote Defect Indication (RDI) cell.
|
|
loopback(2) - Loopback cell."
|
|
::= { atmNteOamEntry 2 }
|
|
|
|
atmNteOamLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
-- f4 (2),
|
|
f5 (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The level of the OAM cell.
|
|
-- f4 (2) - VP level,
|
|
f5 (3) - VC level."
|
|
::= { atmNteOamEntry 3 }
|
|
|
|
atmNteOamEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines if the specified OAM cells
|
|
will be enabled."
|
|
::= { atmNteOamEntry 4 }
|
|
|
|
|
|
atmNteDefaultLoopbackThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Default OAM Loopback Failure Threshold value
|
|
that will be used for configuration."
|
|
::= { atmNteSysConfig 27 }
|
|
|
|
atmNteMaxBurstSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Maximum allowed burst size (cell units).
|
|
This object is applicable for each Physical port."
|
|
::= { atmNteSysConfig 28 }
|
|
|
|
atmNteGranularityFactor OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter affects the granularity of the guaranteed
|
|
Rate (SCR+MCR) in spaced connection (cell/sec units).
|
|
It is also defines the minimum guaranteed rate in spaced
|
|
connection."
|
|
::= { atmNteSysConfig 29 }
|
|
|
|
|
|
atmNteTotalInputRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates the total input rate of the
|
|
device in cells/sec."
|
|
::= { atmNteSysConfig 30 }
|
|
|
|
atmNteTotalOutputRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates the total output rate of the
|
|
device in cells/sec."
|
|
::= { atmNteSysConfig 31 }
|
|
|
|
atmAlarmForwardingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmAlarmForwardingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Alarm Forwarding Mechanism will be operated
|
|
for this table entries."
|
|
::= { atmNteSysConfig 32 }
|
|
|
|
atmAlarmForwardingEntry OBJECT-TYPE
|
|
SYNTAX AtmAlarmForwardingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in this table is a pair of ports that
|
|
the Alarm Forwarding Mechanism is determined for."
|
|
INDEX { atmAlarmForwardingFailPort, atmAlarmForwardingToPort }
|
|
::= { atmAlarmForwardingTable 1 }
|
|
|
|
AtmAlarmForwardingEntry ::=
|
|
SEQUENCE {
|
|
atmAlarmForwardingFailPort
|
|
Integer32,
|
|
atmAlarmForwardingToPort
|
|
Integer32,
|
|
atmAlarmForwardingRowStatus
|
|
RowStatus,
|
|
atmAlarmForwardingFailureLevel
|
|
BITS,
|
|
atmAlarmForwardingRecoveryMode
|
|
INTEGER,
|
|
atmAlarmForwardingRecoveryCommand
|
|
INTEGER,
|
|
atmAlarmForwardingTimeFilterWindow
|
|
Unsigned32
|
|
}
|
|
|
|
atmAlarmForwardingFailPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Index of the port on which a fail occurs."
|
|
::= { atmAlarmForwardingEntry 1 }
|
|
|
|
atmAlarmForwardingToPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Index of the port that will be affected
|
|
upon the failure of the atmAlarmForwardingFailPort."
|
|
::= { atmAlarmForwardingEntry 2 }
|
|
|
|
atmAlarmForwardingRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= { atmAlarmForwardingEntry 3 }
|
|
|
|
atmAlarmForwardingFailureLevel OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
physical (0),
|
|
atm (1)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the level of failure
|
|
that will operate the Alarm Forwarding Mechanism."
|
|
::= { atmAlarmForwardingEntry 4 }
|
|
|
|
atmAlarmForwardingRecoveryMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual (1),
|
|
automatic (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the Recovery Mode.
|
|
manual - The user should stop the RDI transmission
|
|
by using the atmAlarmForwardingRecoveryCommand.
|
|
automatic - The RDI transmission will be automatically
|
|
stopped upon atmAlarmForwardingFailPort
|
|
recovery."
|
|
::= { atmAlarmForwardingEntry 5 }
|
|
|
|
atmAlarmForwardingRecoveryCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is a command. It is applicable when
|
|
atmAlarmForwardingRecoveryMode = manual.
|
|
|
|
on - Will stop the RDI transmission. After setting to 'On'
|
|
the agent will set this parameter back to 'Off'."
|
|
::= { atmAlarmForwardingEntry 6 }
|
|
|
|
atmAlarmForwardingTimeFilterWindow OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the Time Filter Window, meaning:
|
|
how much time (in seconds) should the alarm exist
|
|
in order to start the Alarm Forwarding operation."
|
|
::= { atmAlarmForwardingEntry 7 }
|
|
|
|
|
|
atmSysConfigCellTest OBJECT IDENTIFIER ::= { atmNteSysConfig 33 }
|
|
|
|
atmSysConfigCellTestPort OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Index of the port on which the cell test
|
|
will be sent."
|
|
::= { atmSysConfigCellTest 1 }
|
|
|
|
atmSysConfigCellTestVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI on which the cell test will be sent."
|
|
::= { atmSysConfigCellTest 2 }
|
|
|
|
atmSysConfigCellTestVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI on which the cell test will be sent."
|
|
::= { atmSysConfigCellTest 3 }
|
|
|
|
atmSysConfigCellTestPti OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
user (1),
|
|
oamSegment (2),
|
|
oamEndToEnd (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cell type."
|
|
::= { atmSysConfigCellTest 4 }
|
|
|
|
atmSysConfigCellTestClp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clp0 (1),
|
|
clp1 (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the Cell."
|
|
::= { atmSysConfigCellTest 5 }
|
|
|
|
atmSysConfigCellTestOamType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ais (1),
|
|
rdi (2),
|
|
cc (3),
|
|
lb (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OAM type of the Cell. This object is applicable
|
|
if atmSysConfigCellTestPti = oamSegment/oamEndToEnd ."
|
|
::= { atmSysConfigCellTest 6 }
|
|
|
|
atmSysConfigCellTestPayload OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The payload of the cell. For OAM cell the payload
|
|
is set automatically to 6A."
|
|
::= { atmSysConfigCellTest 7 }
|
|
|
|
atmSysConfigCellTestQuantity OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Quantity of cells to send."
|
|
::= { atmSysConfigCellTest 8 }
|
|
|
|
atmSysConfigCellTestSendCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
send (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the variable to send(3) perfroms cell test.
|
|
The agent will immediately reset the variable to off(2)."
|
|
::= { atmSysConfigCellTest 9 }
|
|
|
|
|
|
|
|
-- The ATM VP Cross Connect Extension Table
|
|
|
|
atmVpCrossConnectExtenTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpCrossConnectExtenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An extension to the ATM VP Cross Connect table
|
|
(RFC2515 - atmVpCrossConnectTable)."
|
|
::= { atmNteSysConfig 34 }
|
|
|
|
atmVpCrossConnectExtenEntry OBJECT-TYPE
|
|
SYNTAX AtmVpCrossConnectExtenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table."
|
|
AUGMENTS { atmVpCrossConnectEntry }
|
|
::= { atmVpCrossConnectExtenTable 1 }
|
|
|
|
AtmVpCrossConnectExtenEntry ::= SEQUENCE {
|
|
atmVpCrossConnectName SnmpAdminString
|
|
}
|
|
|
|
atmVpCrossConnectName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (1..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Connection's name."
|
|
::= { atmVpCrossConnectExtenEntry 1 }
|
|
|
|
|
|
-- The ATM VC Cross Connect Extension Table
|
|
|
|
atmVcCrossConnectExtenTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcCrossConnectExtenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An extension to the ATM VC Cross Connect table
|
|
(RFC2515 - atmVcCrossConnectTable)."
|
|
::= { atmNteSysConfig 35 }
|
|
|
|
atmVcCrossConnectExtenEntry OBJECT-TYPE
|
|
SYNTAX AtmVcCrossConnectExtenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table."
|
|
AUGMENTS { atmVcCrossConnectEntry }
|
|
::= { atmVcCrossConnectExtenTable 1 }
|
|
|
|
AtmVcCrossConnectExtenEntry ::= SEQUENCE {
|
|
atmVcCrossConnectName SnmpAdminString
|
|
}
|
|
|
|
atmVcCrossConnectName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (1..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Connection's name."
|
|
::= { atmVcCrossConnectExtenEntry 1 }
|
|
|
|
|
|
-- The Congestion Thresholds Configuration Table
|
|
|
|
atmCongestionThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmCongestionThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Congestion Thresholds Configuration Table."
|
|
::= { atmNteSysConfig 36 }
|
|
|
|
atmCongestionThresholdEntry OBJECT-TYPE
|
|
SYNTAX AtmCongestionThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table."
|
|
INDEX { atmCongestionThresholdType, atmCongestionThresholdServiceCategory }
|
|
::= { atmCongestionThresholdTable 1 }
|
|
|
|
AtmCongestionThresholdEntry ::= SEQUENCE {
|
|
atmCongestionThresholdType INTEGER,
|
|
atmCongestionThresholdServiceCategory INTEGER,
|
|
atmCongestionThresholdValue Integer32
|
|
}
|
|
|
|
atmCongestionThresholdType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
global (1),
|
|
clp01 (2),
|
|
clp1Upper (3),
|
|
clp1Lower (4)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Congestion Threshold Type."
|
|
::= { atmCongestionThresholdEntry 1 }
|
|
|
|
atmCongestionThresholdServiceCategory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
cbr (1),
|
|
rtVbr (2),
|
|
ubrPlus (3),
|
|
ubr (4)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Congestion Threshold Service Category."
|
|
::= { atmCongestionThresholdEntry 2 }
|
|
|
|
atmCongestionThresholdValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Congestion Threshold Value."
|
|
::= { atmCongestionThresholdEntry 3 }
|
|
|
|
|
|
atmNteQosMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
multipleVc (2),
|
|
singleVc (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable defines the QoS Mode.
|
|
disable(1) - QoS is disabled.
|
|
multipleVc(2) - QoS is enabled and
|
|
multiple VCs can be bound per bridge port.
|
|
singleVc(3) - QoS is enabled and
|
|
only single VC can be bound per bridge port."
|
|
::= { atmNteSysConfig 37 }
|
|
|
|
|
|
atmNteSysInfo OBJECT IDENTIFIER ::= {atmNteSys 2}
|
|
|
|
atmNteIdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IDs of the cards and of the system."
|
|
::= { atmNteSysInfo 1 }
|
|
|
|
atmNteIdEntry OBJECT-TYPE
|
|
SYNTAX AtmNteIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
INDEX { atmNteIdIndex}
|
|
::= { atmNteIdTable 1 }
|
|
|
|
AtmNteIdEntry ::=
|
|
SEQUENCE {
|
|
atmNteIdIndex
|
|
Integer32,
|
|
atmNteUnitId
|
|
Integer32,
|
|
atmNteUnitVersion
|
|
DisplayString,
|
|
atmNteCardType
|
|
INTEGER,
|
|
atmNteCardStatus
|
|
INTEGER,
|
|
atmNteCardCmd
|
|
INTEGER,
|
|
atmNteProgCardType
|
|
INTEGER
|
|
}
|
|
|
|
atmNteIdIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Index of the Unit ID table.
|
|
The following units have IDs in this table:
|
|
1 - System
|
|
2 - ATM Board
|
|
3 - User Card
|
|
4 - Trunk 1 card
|
|
5 - Trunk 2 card
|
|
6 - Shaper
|
|
7 - Clock Unit
|
|
8 - Slot 1 card
|
|
9 - Slot 2 card
|
|
10 - Slot 3 card
|
|
11 - Slot 4 card
|
|
12 - Fan1
|
|
13 - Fan2
|
|
14 - Control Unit."
|
|
::= { atmNteIdEntry 1 }
|
|
|
|
atmNteUnitId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of the Unit.
|
|
For index = 6, the id will describe the validity
|
|
of a shaper in the system: 0 - Shaper Not exist
|
|
1 - Shaper exist.
|
|
For index = 7, the id will describe the validity
|
|
of a clock in the system: 0 - Clock Not exist
|
|
1 - Clock exist.
|
|
2- Clock exist but failed.
|
|
For index = 12,13 the id will describe the functionality
|
|
of a FAN1 : 0 - OK
|
|
1 - Failed."
|
|
::= { atmNteIdEntry 2 }
|
|
|
|
atmNteUnitVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware and Software version
|
|
of the module."
|
|
::= { atmNteIdEntry 3 }
|
|
|
|
atmNteCardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
sc13mR155 (2),
|
|
st13sR155 (3),
|
|
st13lR155 (4),
|
|
utpR155 (5),
|
|
cxBncR155 (6),
|
|
e3 (7),
|
|
t3 (8),
|
|
e1 (9),
|
|
e1Ltu (10),
|
|
fc13lR155 (11),
|
|
fc13lhR155 (12),
|
|
fc15lhR155 (13),
|
|
fc13lE3 (14),
|
|
fc13lhE3 (15),
|
|
fc15lhE3 (16),
|
|
fc13lT3 (17),
|
|
fc13lhT3 (18),
|
|
fc15lhT3 (19),
|
|
t1 (20),
|
|
eth (21),
|
|
ethE1CesBnc (22),
|
|
ethE1CesRj45 (23),
|
|
ethT1CesRj45 (24),
|
|
e1CesRj45 (25),
|
|
e1CesBnc (26),
|
|
t1CesRj45 (27),
|
|
e14Ces (28),
|
|
e14CesRj45 (29),
|
|
t14CesRj45 (30),
|
|
|
|
hdlc4port (31),
|
|
hdlcE14CesBnc (32),
|
|
hdlcE14CesRj45 (33),
|
|
hdlcT14CesRj45 (34),
|
|
e1Rj45 (35),
|
|
e1Bnc (36),
|
|
|
|
ethE14CesBnc (37),
|
|
ethE14CesRj45 (38),
|
|
ethT14CesRj45 (39),
|
|
|
|
hdlc1portHssi (40),
|
|
hdlcHssiE14CesBnc (41),
|
|
hdlcHssiE14CesRj45 (42),
|
|
hdlcHssiT14CesRj45 (43),
|
|
|
|
e14ImaRj45 (44),
|
|
e14ImaBnc (45),
|
|
t14ImaRj45 (46),
|
|
|
|
ethE3CesBnc (47),
|
|
ethT3CesBnc (48),
|
|
|
|
smSf1R155 (49),
|
|
smSf2R155 (50),
|
|
|
|
sc13sR155 (51),
|
|
sc13lR155 (52),
|
|
|
|
utp25 (53),
|
|
|
|
sc13lhR155 (54),
|
|
sc15lhR155 (55),
|
|
|
|
sc13ljR155 (56),
|
|
sc13lhjR155 (57),
|
|
sc15lhjR155 (58),
|
|
|
|
e18Ces (59),
|
|
e18CesRj45 (60),
|
|
t18CesRj45 (61),
|
|
|
|
sc13mR622 (62),
|
|
-- st13sR622 (63),
|
|
-- st13lR622 (64),
|
|
-- utpR622 (65),
|
|
-- cxBncR622 (66),
|
|
-- fc13lR622 (67),
|
|
-- fc13lhR622 (68),
|
|
-- fc15lhR622 (69),
|
|
-- smSf1R622 (70),
|
|
-- smSf2R622 (71),
|
|
-- sc13sR622 (72),
|
|
sc13lR622 (73),
|
|
sc13lhR622 (74),
|
|
sc15lhR622 (75),
|
|
|
|
fr4Port (76),
|
|
t3j (77),
|
|
fr1Port (78),
|
|
hdlc1Port (79),
|
|
|
|
sc13mR155D (80),
|
|
sc13lR155D (81),
|
|
fc13lR155D (82),
|
|
st13lR155D (83),
|
|
sc13lhR155D (84),
|
|
fc13lhR155D (85),
|
|
st13lhR155D (86),
|
|
|
|
e18ImaBnc (87),
|
|
e18ImaRj45 (88),
|
|
t18ImaRj45 (89),
|
|
|
|
lanUtpE (90),
|
|
lanLc13lE (91),
|
|
lanLc13mE (92),
|
|
|
|
e14ImaRj45CfgMode (93),
|
|
e14ImaBncCfgMode (94),
|
|
t14ImaRj45CfgMode (95),
|
|
|
|
sc13mR155R (96), --Dual for Redundancy
|
|
sc13lR155R (97), --Dual for Redundancy
|
|
fc13lR155R (98), --Dual for Redundancy
|
|
st13lR155R (99), --Dual for Redundancy
|
|
sc13lhR155R (100), --Dual for Redundancy
|
|
fc13lhR155R (101), --Dual for Redundancy
|
|
st13lhR155R (102), --Dual for Redundancy
|
|
|
|
fEthUtpD (103),
|
|
fEthSmD (104),
|
|
fEthMmD (105),
|
|
|
|
e14CesRj45Unbal (106),
|
|
|
|
sc13mR155n (107),
|
|
sc13lR155n (108),
|
|
sc13lhR155n (109),
|
|
sc15lhR155n (110),
|
|
fc13lR155n (111),
|
|
fc13lhR155n (112),
|
|
fc15lhR155n (113),
|
|
st13lR155n (114),
|
|
|
|
lanUtp (115),
|
|
lanLc13l (116),
|
|
lanLc13m (117),
|
|
|
|
e1FrHdlc (118),
|
|
e1FrHdlcUnbal (119),
|
|
t1FrHdlc (120),
|
|
|
|
channelizedT3 (121), --for IP-MUX16
|
|
|
|
fc15lhR155D (122), --Dual STM-1
|
|
sc15lhR155D (123), --Dual STM-1
|
|
smSf1R155D (124), --Dual STM-1
|
|
smSf2R155D (125), --Dual STM-1
|
|
smSf3R155D (126), --Dual STM-1
|
|
|
|
fc15lhR155R (127), --Dual for Redundancy
|
|
sc15lhR155R (128), --Dual for Redundancy
|
|
smSf1R155R (129), --Dual for Redundancy
|
|
smSf2R155R (130), --Dual for Redundancy
|
|
smSf3R155R (131), --Dual for Redundancy
|
|
|
|
st13lhR155n (132), --New STM-1
|
|
smSf1R155n (133), --New STM-1
|
|
smSf2R155n (134), --New STM-1
|
|
smSf3R155n (135), --New STM-1
|
|
|
|
t18CesNg (136),
|
|
e18CesUnbalNg (137),
|
|
e18CesBalNg (138),
|
|
t14CesNg (139),
|
|
e14CesUnbalNg (140),
|
|
e14CesBalNg (141),
|
|
|
|
t18ImaUniNg (142),
|
|
e18ImaUniUnbalNg(143),
|
|
e18ImaUniBalNg (144),
|
|
t14ImaUniNg (145),
|
|
e14ImaUniUnbalNg(146),
|
|
e14ImaUniBalNg (147),
|
|
|
|
t1Ces (148),
|
|
e1CesUnbal (149),
|
|
e1CesBal (150),
|
|
|
|
switchedLan (151), --LAN card with ETH switch (usually 4 ports)
|
|
channelizedSts1 (152), --Channelized STS1 card (for IP-MUX16)
|
|
|
|
st13mR155 (153),
|
|
st13lhR155 (154),
|
|
st15lhR155 (155),
|
|
|
|
gigabitEthUtp (156),
|
|
gigabitEthSfp (157),
|
|
fastEthUtp (158),
|
|
|
|
main (251),
|
|
control (252),
|
|
fan (253),
|
|
unknown (254),
|
|
empty (255)
|
|
|
|
-- values 1000 and up are reserved
|
|
-- (used by atmNteProgCardType)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The card type."
|
|
::= { atmNteIdEntry 4 }
|
|
|
|
atmNteCardStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
notActive (2),
|
|
active (3),
|
|
inProgress (4),
|
|
empty (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the card in the selected slot.
|
|
|
|
notActive - Connections are in NotReady state. No configuration is
|
|
available for the card. The access to the card HW is blocked.
|
|
This state is relevant for an extracted card, and for a case
|
|
in which the card was deactivated.
|
|
active - The module installed and functions. A card that in this state
|
|
can be configured.
|
|
inProgress - The status during proccessing of a command from atmNteCardCmd.
|
|
empty - No information is valid for the selected slot. This status is
|
|
relevant to a case in which the card configaration was deleted,
|
|
or in case in which a slot was empty since the device startup."
|
|
::= { atmNteIdEntry 5 }
|
|
|
|
atmNteCardCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
deleteConfig (2),
|
|
deactivate (3),
|
|
activate (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Command on the card that is installed in the selected slot.
|
|
The commands are applicable according to the value of atmNteCardStatus.
|
|
See the specification document for details.
|
|
|
|
deleteConfig - Deletes the card configuration.
|
|
deactivate - All the connections state will be changed to NotReady. The card
|
|
configuration will be blocked.
|
|
activate - Does the same as done upon card insertion: Initiates the relevant
|
|
parameters, activates the physical layer, ATM layer and logical
|
|
layer."
|
|
::= { atmNteIdEntry 6 }
|
|
|
|
atmNteProgCardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- values 1...1000 (if needed) should be used
|
|
-- the same as in atmNteCardType
|
|
main (251),
|
|
control (252),
|
|
fan (253),
|
|
empty (255),
|
|
|
|
atm155 (1001),
|
|
eth (1002)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The programmed card type."
|
|
::= { atmNteIdEntry 7 }
|
|
|
|
|
|
atmSysPSunits OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of power supply units."
|
|
::= { atmNteSysInfo 2 }
|
|
|
|
atmSysPSunitsInUse OBJECT-TYPE
|
|
SYNTAX INTEGER { ps1(2), ps2(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main power supply in this unit."
|
|
::= { atmNteSysInfo 3 }
|
|
|
|
atmSysFanUnits OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of fan units."
|
|
::= { atmNteSysInfo 4 }
|
|
|
|
atmSysNetPrts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of network ports."
|
|
::= { atmNteSysInfo 5 }
|
|
|
|
atmSysNetPrtInUse OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
trunk1(2),
|
|
trunk2(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The network port in use."
|
|
::= { atmNteSysInfo 6 }
|
|
|
|
atmNteBridgingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
accessOnly(1),
|
|
accessAndSwitching (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bridging mode can be one of the following:
|
|
ATM <> Ethernet - Bridging is between the Ethernet
|
|
port and the ATM port (there is no bridging between VCs).
|
|
ATM <> Ethernet + ATM - Bridging is done both between
|
|
the Ethernet port and the ATM port and also between VCs."
|
|
::= { atmNteSysInfo 7}
|
|
|
|
atmSysStats OBJECT IDENTIFIER ::= { atmNteSysInfo 8 }
|
|
|
|
atmSysCurrentCdc OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Seconds in which cells dropped was occured in
|
|
the current 15 minutes interval."
|
|
::= { atmSysStats 1 }
|
|
|
|
atmSysIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmSysIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system level Interval table."
|
|
::= { atmSysStats 2 }
|
|
|
|
atmSysIntervalEntry OBJECT-TYPE
|
|
SYNTAX AtmSysIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
INDEX { atmSysIntervalNumber }
|
|
::= { atmSysIntervalTable 1 }
|
|
|
|
AtmSysIntervalEntry ::=
|
|
SEQUENCE {
|
|
atmSysIntervalNumber
|
|
Integer32,
|
|
atmSysIntervalCdc
|
|
Gauge32
|
|
}
|
|
|
|
atmSysIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals are valid)."
|
|
::= { atmSysIntervalEntry 1 }
|
|
|
|
atmSysIntervalCdc OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Seconds in which cells dropped was occured in
|
|
15 minutes interval."
|
|
::= { atmSysIntervalEntry 2 }
|
|
|
|
atmNteEventType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ps1NotActive (3),
|
|
ps1Active (4),
|
|
ps2NotActive (5),
|
|
ps2Active (6),
|
|
heatAlarmOff (7),
|
|
heatAlarmOn (8),
|
|
inputAlarm1Off (9),
|
|
inputAlarm1On (10),
|
|
inputAlarm2Off (11),
|
|
inputAlarm2On (12),
|
|
inputAlarm3Off (13),
|
|
inputAlarm3On (14),
|
|
inputAlarm4Off (15),
|
|
inputAlarm4On (16),
|
|
fan1Ok (17),
|
|
fan1Fail (18),
|
|
fan2Ok (19),
|
|
fan2Fail (20),
|
|
invalidLogin (21),
|
|
validLogin (22),
|
|
powerFailure (23),
|
|
writeToFlashFailure (24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter identifies the event.
|
|
On - the problem exist.
|
|
Off - the problem not exist.
|
|
InvalidLogin - Invalid login on local console.
|
|
CorrectLogin - Successful login operation."
|
|
::= { atmNteSysInfo 9 }
|
|
|
|
atmNteIntervalMaxNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAX number of connections intervals supported by system.
|
|
This parameter value is a function of atmNteConnectionsMaxNumber
|
|
parameter.
|
|
This parameter should affect the threshold values selected by user.
|
|
Applicable to ace2002."
|
|
::= { atmNteSysInfo 10 }
|
|
|
|
atmNteAlarmType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
ais(2),
|
|
rdi(3),
|
|
continuityLoss(4),
|
|
loopback(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the type of the alarm."
|
|
::= { atmNteSysInfo 11 }
|
|
|
|
atmNteLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
vp(2),
|
|
vc(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the ATM level."
|
|
::= { atmNteSysInfo 12 }
|
|
|
|
atmNteConnectionsNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies a quantity of connections."
|
|
::= { atmNteSysInfo 13 }
|
|
|
|
atmNteTotalLb OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter counts the total number of end-points
|
|
that were configured with Loopback (LB)."
|
|
::= { atmNteSysInfo 14 }
|
|
|
|
atmNteTotalCc OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter counts the total number of end-points
|
|
that were configured with Continuity Check (CC)."
|
|
::= { atmNteSysInfo 15 }
|
|
|
|
atmNteTotalPm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter counts the total number of end-points
|
|
that were configured with PM."
|
|
::= { atmNteSysInfo 16 }
|
|
|
|
|
|
--atmNtePrt OBJECT IDENTIFIER ::= {atmNte 2}
|
|
|
|
-- Changed
|
|
atmNteLoopback OBJECT IDENTIFIER ::= {atmNtePrt 2}
|
|
-- The loopback test consists of inserting special OAM cells. This test is started and stopped
|
|
-- upon operator request (by using MIB item atmVpConfLoopbackAdminStatus).
|
|
-- There are two tables per VP and two tables per VC: the measurements of the current 15 minutes,
|
|
-- and the measurement of the last 96 periods of 15 minutes.
|
|
atmLoopbackVpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmLoopbackVpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains parameters for an OAM VP loopback test."
|
|
::= {atmNteLoopback 1 }
|
|
|
|
atmLoopbackVpEntry OBJECT-TYPE
|
|
SYNTAX AtmLoopbackVpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table atmLoopbackVpTable."
|
|
INDEX {atmLoopbackVpIfIndex,atmLoopbackVpVpi}
|
|
::= {atmLoopbackVpTable 1}
|
|
|
|
AtmLoopbackVpEntry ::=
|
|
SEQUENCE {
|
|
atmLoopbackVpIfIndex Integer32,
|
|
atmLoopbackVpVpi Integer32,
|
|
atmLoopbackVpOperStatus INTEGER,
|
|
atmLoopbackVpCDV Integer32,
|
|
atmLoopbackVpAverageDelay Integer32,
|
|
atmLoopbackVpMaxDelay Integer32,
|
|
atmLoopbackVpMinDelay Integer32,
|
|
atmLoopbackVpErrSessions Integer32
|
|
}
|
|
|
|
atmLoopbackVpIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface index of the ATM layer."
|
|
::= {atmLoopbackVpEntry 1}
|
|
|
|
atmLoopbackVpVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the OAM VPL."
|
|
::= {atmLoopbackVpEntry 2}
|
|
|
|
|
|
atmLoopbackVpOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noActive(1),
|
|
inProgress(2),
|
|
failed(3),
|
|
endSuccessfully(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-noActive(1) means that the loopback test has not been activated for this VP.
|
|
-inProgress(2) means that the test has been activated and there is currently no problem.
|
|
-failed(3) means there was problem during the test or after having stopped it
|
|
-endSuccessfully(4) means that the test was stopped and all was OK."
|
|
::= {atmLoopbackVpEntry 3}
|
|
|
|
atmLoopbackVpCDV OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Delay Variation for this sampling."
|
|
::= {atmLoopbackVpEntry 4}
|
|
|
|
atmLoopbackVpAverageDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Average delay without including lost cells."
|
|
::= {atmLoopbackVpEntry 5}
|
|
|
|
atmLoopbackVpMaxDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum delay without including lost cells."
|
|
::= {atmLoopbackVpEntry 6}
|
|
|
|
atmLoopbackVpMinDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum delay."
|
|
::= {atmLoopbackVpEntry 7}
|
|
|
|
atmLoopbackVpErrSessions OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Errored Sessions. Will be updated once in 5 seconds."
|
|
::= {atmLoopbackVpEntry 8}
|
|
|
|
atmLoopbackVcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmLoopbackVcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains parameters for an OAM VC loopback test."
|
|
::= {atmNteLoopback 2 }
|
|
|
|
atmLoopbackVcEntry OBJECT-TYPE
|
|
SYNTAX AtmLoopbackVcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {atmLoopbackVcIfIndex,atmLoopbackVcVpi,atmLoopbackVcVci}
|
|
::= {atmLoopbackVcTable 1}
|
|
|
|
AtmLoopbackVcEntry ::=
|
|
SEQUENCE {
|
|
atmLoopbackVcIfIndex Integer32,
|
|
atmLoopbackVcVpi Integer32,
|
|
atmLoopbackVcVci Integer32,
|
|
atmLoopbackVcOperStatus INTEGER,
|
|
atmLoopbackVcCDV Integer32,
|
|
atmLoopbackVcAverageDelay Integer32,
|
|
atmLoopbackVcMaxDelay Integer32,
|
|
atmLoopbackVcMinDelay Integer32,
|
|
atmLoopbackVcErrSessions Integer32
|
|
}
|
|
|
|
atmLoopbackVcIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface index of the ATM layer."
|
|
::= {atmLoopbackVcEntry 1}
|
|
|
|
atmLoopbackVcVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the OAM VCL."
|
|
::= {atmLoopbackVcEntry 2}
|
|
|
|
atmLoopbackVcVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the OAM VCL."
|
|
::= {atmLoopbackVcEntry 3}
|
|
|
|
|
|
atmLoopbackVcOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noActive(1),
|
|
inProgress(2),
|
|
failed(3),
|
|
endSuccessfully(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-noActive(1) means that the loopback test has not been activated for this VP.
|
|
-inProgress(2) means that the test has been activated and there is currently no problem.
|
|
-failed(3) means there was problem during the test or after having stopped it
|
|
-endSuccessfully(4) means that the test was stopped and all was OK."
|
|
::= {atmLoopbackVcEntry 4}
|
|
|
|
atmLoopbackVcCDV OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Delay Variation for this sampling."
|
|
::= {atmLoopbackVcEntry 5}
|
|
|
|
|
|
atmLoopbackVcAverageDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Average delay without including lost cells."
|
|
::= {atmLoopbackVcEntry 6}
|
|
|
|
atmLoopbackVcMaxDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum delay without including lost cells."
|
|
::= {atmLoopbackVcEntry 7}
|
|
|
|
atmLoopbackVcMinDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum delay."
|
|
::= {atmLoopbackVcEntry 8}
|
|
|
|
atmLoopbackVcErrSessions OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Errored Sessions. Will be updated once in 5 seconds."
|
|
::= {atmLoopbackVcEntry 9}
|
|
|
|
|
|
-- Entirely New
|
|
atmLoopbackVpIvlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmLoopbackVpIvlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains parameters for an OAM VP loopback test,
|
|
according interval number."
|
|
::= {atmNteLoopback 3 }
|
|
|
|
atmLoopbackVpIvlEntry OBJECT-TYPE
|
|
SYNTAX AtmLoopbackVpIvlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { atmLoopbackVpIvlIfIndex, atmLoopbackVpIvlVpi, atmLoopbackVpIvlIvl }
|
|
::= { atmLoopbackVpIvlTable 1}
|
|
|
|
AtmLoopbackVpIvlEntry ::=
|
|
SEQUENCE {
|
|
atmLoopbackVpIvlIfIndex Integer32,
|
|
atmLoopbackVpIvlVpi Integer32,
|
|
atmLoopbackVpIvlIvl Integer32,
|
|
atmLoopbackVpIvlOperStatus INTEGER,
|
|
atmLoopbackVpIvlCDV Integer32,
|
|
atmLoopbackVpIvlAverageDelay Integer32,
|
|
atmLoopbackVpIvlMaxDelay Integer32,
|
|
atmLoopbackVpIvlMinDelay Integer32,
|
|
atmLoopbackVpIvlErrSessions Integer32
|
|
}
|
|
|
|
atmLoopbackVpIvlIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface index of the ATM layer."
|
|
::= { atmLoopbackVpIvlEntry 1}
|
|
|
|
atmLoopbackVpIvlVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the OAM VPL."
|
|
::= { atmLoopbackVpIvlEntry 2}
|
|
|
|
|
|
atmLoopbackVpIvlIvl OBJECT-TYPE
|
|
SYNTAX Integer32(1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The relevant interval number."
|
|
::= { atmLoopbackVpIvlEntry 3}
|
|
|
|
atmLoopbackVpIvlOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noActive(1),
|
|
inProgress(2),
|
|
failed(3),
|
|
endSuccessfully(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-noActive(1) means that the loopback test has not been activated for this VP during this interval.
|
|
-inProgress(2) has no meaning for an ended interval.
|
|
-failed(3) means there was problem during the test or after having stopped it
|
|
-endSuccessfully(4) means that the test was OK."
|
|
::= { atmLoopbackVpIvlEntry 4}
|
|
|
|
atmLoopbackVpIvlCDV OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Delay Variation for this interval."
|
|
::= { atmLoopbackVpIvlEntry 5}
|
|
|
|
|
|
atmLoopbackVpIvlAverageDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Average delay without including lost cells for this interval."
|
|
::= { atmLoopbackVpIvlEntry 6}
|
|
|
|
atmLoopbackVpIvlMaxDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum delay without including lost cells for this interval."
|
|
::= { atmLoopbackVpIvlEntry 7}
|
|
|
|
atmLoopbackVpIvlMinDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum delay for this interval."
|
|
::= {atmLoopbackVpIvlEntry 8}
|
|
|
|
atmLoopbackVpIvlErrSessions OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Errored Sessions. Will be updated once in 5 seconds."
|
|
::= {atmLoopbackVpIvlEntry 9}
|
|
|
|
|
|
atmLoopbackVcIvlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmLoopbackVcIvlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains parameters for an OAM VC loopback test."
|
|
::= {atmNteLoopback 4 }
|
|
|
|
atmLoopbackVcIvlEntry OBJECT-TYPE
|
|
SYNTAX AtmLoopbackVcIvlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {atmLoopbackVcIvlIfIndex, atmLoopbackVcIvlVpi, atmLoopbackVcIvlVci, atmLoopbackVcIvlIvl }
|
|
::= {atmLoopbackVcIvlTable 1}
|
|
|
|
AtmLoopbackVcIvlEntry ::=
|
|
SEQUENCE {
|
|
atmLoopbackVcIvlIfIndex Integer32,
|
|
atmLoopbackVcIvlVpi Integer32,
|
|
atmLoopbackVcIvlVci Integer32,
|
|
atmLoopbackVcIvlIvl Integer32,
|
|
atmLoopbackVcIvlOperStatus INTEGER,
|
|
atmLoopbackVcIvlCDV Integer32,
|
|
atmLoopbackVcIvlAverageDelay Integer32,
|
|
atmLoopbackVcIvlMaxDelay Integer32,
|
|
atmLoopbackVcIvlMinDelay Integer32,
|
|
atmLoopbackVcIvlErrSessions Integer32
|
|
}
|
|
|
|
atmLoopbackVcIvlIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface index of the ATM layer."
|
|
::= {atmLoopbackVcIvlEntry 1}
|
|
|
|
atmLoopbackVcIvlVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the OAM VCL."
|
|
::= {atmLoopbackVcIvlEntry 2}
|
|
|
|
atmLoopbackVcIvlVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the OAM VCL."
|
|
::= {atmLoopbackVcIvlEntry 3}
|
|
|
|
atmLoopbackVcIvlIvl OBJECT-TYPE
|
|
SYNTAX Integer32(1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The relevant interval number."
|
|
::= {atmLoopbackVcIvlEntry 4}
|
|
|
|
atmLoopbackVcIvlOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noActive(1),
|
|
inProgress(2),
|
|
failed(3),
|
|
endSuccessfully(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-noActive(1) means that the loopback test has not been activated for this VC during this interval.
|
|
-inProgress(2) has no meaning per interval.
|
|
-failed(3) means there was problem for this test during this interval.
|
|
-endSuccessfully(4) means that the test was OK."
|
|
::= {atmLoopbackVcIvlEntry 5}
|
|
|
|
atmLoopbackVcIvlCDV OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cell Delay Variation for this interval."
|
|
::= {atmLoopbackVcIvlEntry 6}
|
|
|
|
|
|
atmLoopbackVcIvlAverageDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Average delay without including lost cells."
|
|
::= {atmLoopbackVcIvlEntry 7}
|
|
|
|
atmLoopbackVcIvlMaxDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum delay without including lost cells."
|
|
::= {atmLoopbackVcIvlEntry 8}
|
|
|
|
atmLoopbackVcIvlMinDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum delay."
|
|
::= {atmLoopbackVcIvlEntry 9}
|
|
|
|
atmLoopbackVcIvlErrSessions OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Errored Sessions. Will be updated once in 5 seconds."
|
|
::= {atmLoopbackVcIvlEntry 10}
|
|
|
|
|
|
atmNtePM OBJECT IDENTIFIER ::= {atmNtePrt 3}
|
|
|
|
atmVpPmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVpPmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains parameters for VP performance monitoring."
|
|
::= {atmNtePM 1 }
|
|
|
|
atmVpPmEntry OBJECT-TYPE
|
|
SYNTAX AtmVpPmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {atmVpPmIfIndex,atmVpPmVpi}
|
|
::= {atmVpPmTable 1}
|
|
|
|
AtmVpPmEntry ::=
|
|
SEQUENCE {
|
|
atmVpPmIfIndex Integer32,
|
|
atmVpPmVpi Integer32,
|
|
atmVpPmAdminStatus INTEGER,
|
|
atmVpPmDirection INTEGER,
|
|
atmVpPmBlockSize Integer32,
|
|
atmVpPmRowStatus RowStatus,
|
|
atmVpPmSink INTEGER,
|
|
atmVpPmSource INTEGER
|
|
}
|
|
|
|
atmVpPmIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface index of the ATM layer."
|
|
::= {atmVpPmEntry 1}
|
|
|
|
atmVpPmVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the Performance Monitoring VPL."
|
|
::= {atmVpPmEntry 2}
|
|
|
|
atmVpPmAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (2),
|
|
down(3),
|
|
listenToActivationCells (4),
|
|
originateActivationCells (5)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"up(2) - Activate PM.
|
|
down(3) - Deactivate PM.
|
|
listenToActivationCells(4) - .
|
|
originateActivationCells(5) - ."
|
|
::= {atmVpPmEntry 3}
|
|
|
|
atmVpPmDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
source(2),
|
|
destination(3),
|
|
bidirectional(4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of PM."
|
|
::= {atmVpPmEntry 4}
|
|
|
|
atmVpPmBlockSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096,
|
|
8192, 16384, 32768."
|
|
::= {atmVpPmEntry 5}
|
|
|
|
atmVpPmRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= {atmVpPmEntry 6}
|
|
|
|
atmVpPmSink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
fwd (2),
|
|
fwdAndBwdReport(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"off (1) - Deactivate PM.
|
|
fwd (2) - Activate Forward PM only.
|
|
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
|
|
::= {atmVpPmEntry 7}
|
|
|
|
atmVpPmSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
fwd (2),
|
|
fwdAndBwdReport(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"off (1) - Deactivate PM.
|
|
fwd (2) - Activate Forward PM only.
|
|
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
|
|
::= {atmVpPmEntry 8}
|
|
|
|
|
|
|
|
atmVcPmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmVcPmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains parameters for VC performance monitoring."
|
|
::= {atmNtePM 2 }
|
|
|
|
atmVcPmEntry OBJECT-TYPE
|
|
SYNTAX AtmVcPmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {atmVcPmIfIndex,atmVcPmVpi,atmVcPmVci}
|
|
::= {atmVcPmTable 1}
|
|
|
|
AtmVcPmEntry ::=
|
|
SEQUENCE {
|
|
atmVcPmIfIndex Integer32,
|
|
atmVcPmVpi Integer32,
|
|
atmVcPmVci Integer32,
|
|
atmVcPmAdminStatus INTEGER,
|
|
atmVcPmDirection INTEGER,
|
|
atmVcPmBlockSize Integer32,
|
|
atmVcPmRowStatus RowStatus,
|
|
atmVcPmSink INTEGER,
|
|
atmVcPmSource INTEGER
|
|
}
|
|
|
|
atmVcPmIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface index of the ATM layer."
|
|
::= {atmVcPmEntry 1}
|
|
|
|
atmVcPmVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the Performance Monitoring VCL."
|
|
::= {atmVcPmEntry 2}
|
|
|
|
atmVcPmVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the PM VCL."
|
|
::= {atmVcPmEntry 3}
|
|
|
|
atmVcPmAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (2),
|
|
down(3),
|
|
listenToActivationCells (4),
|
|
originateActivationCells (5)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"up(2) - Activate PM.
|
|
down(3) - Deactivate PM.
|
|
listenToActivationCells(4) - .
|
|
originateActivationCells(5) - ."
|
|
::= {atmVcPmEntry 4}
|
|
|
|
atmVcPmDirection OBJECT-TYPE
|
|
SYNTAX INTEGER { source(2), destination(3), bidirectional(4) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The direction of PM."
|
|
::= {atmVcPmEntry 5}
|
|
|
|
atmVcPmBlockSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096,
|
|
8192, 16384, 32768."
|
|
::= {atmVcPmEntry 6}
|
|
|
|
atmVcPmRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table."
|
|
::= {atmVcPmEntry 7}
|
|
|
|
atmVcPmSink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
fwd (2),
|
|
fwdAndBwdReport(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"off (1) - Deactivate PM.
|
|
fwd (2) - Activate Forward PM only.
|
|
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
|
|
::= {atmVcPmEntry 8}
|
|
|
|
atmVcPmSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
fwd (2),
|
|
fwdAndBwdReport(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"off (1) - Deactivate PM.
|
|
fwd (2) - Activate Forward PM only.
|
|
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
|
|
::= {atmVcPmEntry 9}
|
|
|
|
atmNteMdl OBJECT IDENTIFIER ::= {atmNte 3}
|
|
|
|
atmNteMdlConfig OBJECT IDENTIFIER ::= {atmNteMdl 1}
|
|
|
|
atmNteMdlConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmNteMdlConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module configuration table."
|
|
::= { atmNteMdlConfig 1 }
|
|
|
|
atmNteMdlConfigEntry OBJECT-TYPE
|
|
SYNTAX AtmNteMdlConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There is an entry in this table just for those modules that have
|
|
parameters that are relevant to module level only."
|
|
INDEX {atmNteMdlSlotIndex}
|
|
::= {atmNteMdlConfigTable 1}
|
|
|
|
AtmNteMdlConfigEntry ::=
|
|
SEQUENCE {
|
|
atmNteMdlSlotIndex Integer32,
|
|
atmNteMdlPrtCpuSharing INTEGER,
|
|
atmNteMdlInputPriorityMechanism INTEGER
|
|
}
|
|
|
|
atmNteMdlSlotIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number."
|
|
::= { atmNteMdlConfigEntry 1}
|
|
|
|
atmNteMdlPrtCpuSharing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
equal (2),
|
|
port1 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object lets the user decide what will be the CPU sharing
|
|
between the ports of the module. This object is applicable for
|
|
modules in which the same CPU handles the traffic of all ports.
|
|
|
|
equal - All ports will have the same CPU resource.
|
|
port1 - Port 1 will have higher priority than the other ports."
|
|
::= {atmNteMdlConfigEntry 2}
|
|
|
|
atmNteMdlInputPriorityMechanism OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the user to Enable/Disable the Input priority mechanism.
|
|
This object is applicable for modules with more than one port, in which the
|
|
total ports input may be greater than the port output.
|
|
|
|
disabled - all LAN VCCs will be transmitted through the same queue (queue 1).
|
|
Upon congestion frames will be dropped randomly.
|
|
enabled - the user should configure each port/connection priority. Upon
|
|
congestion frames will be dropped according to priority."
|
|
::= {atmNteMdlConfigEntry 3}
|
|
|
|
|
|
|
|
atmGenSystem OBJECT IDENTIFIER ::= {atmGen 2}
|
|
|
|
--atmGenModules OBJECT IDENTIFIER ::= {atmGen 3} located in ace2002.txt
|
|
|
|
|
|
atmGenSysGen OBJECT IDENTIFIER ::= {atmGenSystem 1}
|
|
|
|
-- The self test table
|
|
|
|
atmGenSysSelfTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmGenSysSelfTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing the results of the initial testing of the device."
|
|
::= { atmGenSysGen 1 }
|
|
|
|
atmGenSysSelfTestEntry OBJECT-TYPE
|
|
SYNTAX AtmGenSysSelfTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {atmGenSysSelfTestIndex}
|
|
::= {atmGenSysSelfTestTable 1}
|
|
|
|
AtmGenSysSelfTestEntry ::=
|
|
SEQUENCE {
|
|
atmGenSysSelfTestIndex Integer32,
|
|
atmGenSysSelfTestResult DisplayString
|
|
}
|
|
|
|
atmGenSysSelfTestIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A running index for the table."
|
|
::= { atmGenSysSelfTestEntry 1}
|
|
|
|
atmGenSysSelfTestResult OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the initial testing of the device."
|
|
::= { atmGenSysSelfTestEntry 2}
|
|
|
|
-- The Log clear all
|
|
|
|
atmGenSysLogClearAll OBJECT-TYPE
|
|
SYNTAX INTEGER { off(2),clear(3)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the variable to clear(3) removes all entries in the
|
|
Log Buffer of the agent. The agent will immediately
|
|
reset the variable to off(2)."
|
|
::= { atmGenSysGen 2}
|
|
|
|
-- The Log table
|
|
|
|
atmGenSysLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmGenSysLogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A copy of the log buffer."
|
|
::= { atmGenSysGen 3 }
|
|
|
|
atmGenSysLogEntry OBJECT-TYPE
|
|
SYNTAX AtmGenSysLogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {atmGenSysLogIndex}
|
|
::= {atmGenSysLogTable 1}
|
|
|
|
AtmGenSysLogEntry ::=
|
|
SEQUENCE {
|
|
atmGenSysLogIndex Integer32,
|
|
atmGenSysLogMessage DisplayString
|
|
}
|
|
|
|
atmGenSysLogIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2048)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the log buffer."
|
|
::= { atmGenSysLogEntry 1}
|
|
|
|
atmGenSysLogMessage OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The log buffer entry message text."
|
|
::= { atmGenSysLogEntry 2}
|
|
|
|
-- Set to default configuration
|
|
|
|
atmGenSysSetDefaultConfg OBJECT-TYPE
|
|
SYNTAX INTEGER { off(2), on(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to on(3), the agent will set all the configuration parameters
|
|
to their default values. The variable is then reset to off(2)
|
|
by the agent. The agent must be reset for the default configuration
|
|
to apply."
|
|
::= {atmGenSysGen 4}
|
|
|
|
-- A Cross Reference table for connections between tables.
|
|
|
|
atmGenSysCxRefTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmGenSysCxRefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Cross Reference table. The table maintains
|
|
an index of an object which is also the table index,
|
|
and a counter that indicates how many times this
|
|
object was referenced.
|
|
When using this table for more than one referenced table,
|
|
which uses the same range of indexes, then the index
|
|
should be shifted by a unique offset per table.
|
|
|
|
In ACE2002 this table is used for TD and for FR Desc. Thus,
|
|
the index for FR Descriptor is: FR Descriptor index + offset.
|
|
The offset is described in the ACE2002 NMS SRS."
|
|
::= {atmGenSysGen 5}
|
|
|
|
atmGenSysCxRefEntry OBJECT-TYPE
|
|
SYNTAX AtmGenSysCxRefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries will be added by the agent upon
|
|
an entry addition in the referenced tables
|
|
(TD table, FR Descriptor etc.)"
|
|
INDEX { atmGenSysCxRefIndex }
|
|
::= { atmGenSysCxRefTable 1 }
|
|
|
|
AtmGenSysCxRefEntry ::=
|
|
SEQUENCE {
|
|
atmGenSysCxRefIndex
|
|
Integer32,
|
|
atmGenSysCxRefCounter
|
|
Gauge32
|
|
}
|
|
|
|
atmGenSysCxRefIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index specifies an entry in the table of the object."
|
|
::= { atmGenSysCxRefEntry 1 }
|
|
|
|
atmGenSysCxRefCounter OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter counts the number of references
|
|
that have been made to the object ."
|
|
::= { atmGenSysCxRefEntry 2 }
|
|
|
|
|
|
|
|
-- Traps
|
|
|
|
-- System Layer Traps
|
|
|
|
atmAceStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {agnLed,agnIndication}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent every time there is a change in
|
|
the state of one of the LEDs."
|
|
::= { atmNteEvents 1 }
|
|
|
|
atmAceAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS {atmInterfaceAlarmStatus}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent whenever there is a transition from a no alarm
|
|
state to a state with at least one active alarm. An active alarm
|
|
state exists if:
|
|
1) The atmInterfaceActiveAlarms vector is different than 0.
|
|
2) The atmNteAlarmVpTable contains entries.
|
|
3) The atmNteAlarmVcTable contains entries.
|
|
The trap is also sent when a transition into the no alarm state
|
|
occurs.
|
|
The second variable will be atmInterfaceActiveAlarms to
|
|
indicate the kind of the alarm.
|
|
The trap is not sent more than once in a 10 second interval."
|
|
::= { atmNteEvents 2 }
|
|
|
|
atmAceModuleChangeTrap NOTIFICATION-TYPE
|
|
OBJECTS {ifIndex}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent every time a module is changed (Hot swapping).
|
|
The second variable will be atmNteCardType to indicate the
|
|
type of card that was inserted. The value empty(255) indicates that
|
|
a card was taken out."
|
|
::= { atmNteEvents 3 }
|
|
|
|
atmAceRedundancyTrap NOTIFICATION-TYPE
|
|
OBJECTS {ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent upon change in link as a result of redundancy.
|
|
The ifIndex parameter indicates the current active link."
|
|
::= { atmNteEvents 4 }
|
|
|
|
atmAceModuleMismatchTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent upon starting or stopping of
|
|
a module mismatch state.
|
|
A possible mismatch is when the inserted module is other
|
|
than the programmed one."
|
|
::= { atmNteEvents 5 }
|
|
|
|
|
|
atmAceSystemTrap NOTIFICATION-TYPE
|
|
OBJECTS { atmNteEventType, agnLed, alarmSeverity }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap alerts of major problems in the device."
|
|
::= { radSysAtmEvents 6 }
|
|
|
|
atmAceAlarmForwardingTrap NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon starting or stopping Alarm
|
|
Forwarding Mechanism."
|
|
::= { radSysAtmEvents 7 }
|
|
|
|
atmAceDateAndTimeRequest NOTIFICATION-TYPE
|
|
-- OBJECTS { sysObjectID }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon restart. It will send sysObjectID variable.
|
|
Upon recieving this trap the NMS will set the device's date and time.
|
|
This trap's purpose is to fix a problem in ACE2002, ACE-2002E, ACE-202.
|
|
The problem is that the Date and Time is stored in the NVRAM,
|
|
and when the NVRAM's battery is empty, the device loses this information."
|
|
::= { radSysAtmEvents 8 }
|
|
|
|
-- Alarms Traps
|
|
atmAceAlarmLOS NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Loss Of Signal."
|
|
::= { radSysAtmEvents 16 }
|
|
|
|
atmAceAlarmLOF NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Loss Of Frame."
|
|
::= { radSysAtmEvents 17 }
|
|
|
|
atmAceAlarmLCD NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Loss of Cell Delineation."
|
|
::= { radSysAtmEvents 18 }
|
|
|
|
atmAceAlarmSLM NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Signal Line Mismatch."
|
|
::= { radSysAtmEvents 19 }
|
|
|
|
atmAceAlarmLOP NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Loss of Pointer."
|
|
::= { radSysAtmEvents 20 }
|
|
|
|
atmAceAlarmLineAIS NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Line AIS."
|
|
::= { radSysAtmEvents 21 }
|
|
|
|
atmAceAlarmPathAIS NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Path AIS."
|
|
::= { radSysAtmEvents 22 }
|
|
|
|
atmAceAlarmLineRDI NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Line RDI."
|
|
::= { radSysAtmEvents 23 }
|
|
|
|
atmAceAlarmPathRDI NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Path RDIand Path RAI(Yellow) for
|
|
DS1 interfaces."
|
|
::= { radSysAtmEvents 24 }
|
|
|
|
atmAceAlarmSectionBIP NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Section Bit Interleave Parity."
|
|
::= { radSysAtmEvents 25 }
|
|
|
|
atmAceAlarmLineBIP NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Line Bit Interleave Parity."
|
|
::= { radSysAtmEvents 26 }
|
|
|
|
atmAceAlarmPathBIP NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Path Bit Interleave Parity."
|
|
::= { radSysAtmEvents 27 }
|
|
|
|
atmAceAlarmLineFEBE NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Line Far End Block Error."
|
|
::= { radSysAtmEvents 28 }
|
|
|
|
atmAceAlarmPathFEBE NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Path Far End Block Error."
|
|
::= { radSysAtmEvents 29 }
|
|
|
|
atmAceAlarmPlcpLOF NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates T3 PLCP Loss Of Frame."
|
|
::= { radSysAtmEvents 30 }
|
|
|
|
|
|
atmAceAlarmPlcpYELLOW NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates T3 Plcp Yellow."
|
|
::= { radSysAtmEvents 31 }
|
|
|
|
atmAceAlarmPlcpBIP NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates T3 Plcp Bit Interleave Parity."
|
|
::= { radSysAtmEvents 32 }
|
|
|
|
atmAceAlarmPlcpFEBE NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates T3 Plcp Far End Block Error."
|
|
::= { radSysAtmEvents 33 }
|
|
|
|
atmAceAlarmPlcpP1P2 NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates T3 Plcp Parity errors in P1/P2 bytes."
|
|
::= { radSysAtmEvents 34 }
|
|
|
|
atmAceAlarmUAS NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon UAS start or end per port."
|
|
::= { radSysAtmEvents 35 }
|
|
|
|
atmAceAlarmCluster NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, atmNteAlarmType, atmNteLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon atmNteAlarmType start or end,
|
|
for a cluster of VPs/VCs (according to atmNteLevel) with
|
|
the same alarm on the same physical port.
|
|
|
|
This trap replaces sending the same alarm for a big
|
|
quantity (the quantity described in the product
|
|
specification document) of VPs/VCs in order to prevent
|
|
flooding the NMS and the network with traps."
|
|
::= { radSysAtmEvents 36 }
|
|
|
|
atmAceHwFailure NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon HW failure per port."
|
|
::= { radSysAtmEvents 37 }
|
|
|
|
atmAceUnavailableBwTrap NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, ifAlias, atmConfIfInputRate, atmConfIfOutputRate }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when Bandwidth allocation is > max possible
|
|
value for the installed card.
|
|
|
|
For ACE2002 this trap will be sent for the following cases:
|
|
|
|
Card insertion - if the total Input and/or Output Bandwidth is over
|
|
allocated, then the specific card rate will be set to 0 and this trap
|
|
will be sent with the Input/Output rates values.
|
|
|
|
Upgrade from former version - when an over allocated Bandwidth is detected,
|
|
this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF."
|
|
::= { radSysAtmEvents 38 }
|
|
|
|
|
|
--
|
|
-- OAM LOOPBACK
|
|
-- atmAceOAMLoopBackCellRx NOTIFICATION-TYPE
|
|
-- OBJECTS { alarmSeverity, alarmState,ifAlias }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This Trap indicates that a loopback has
|
|
-- been activated on device ATM uplink interface
|
|
-- by the remote ATM equipment, by means of OAM cells"
|
|
-- ::= { radSysAtmEvents 39 }
|
|
--
|
|
--
|
|
-- OAM LOOPBACK
|
|
-- atmAceOAMLoopBackCellTx NOTIFICATION-TYPE
|
|
-- OBJECTS { alarmSeverity, alarmState,ifAlias }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This Trap indicates that a loopback has
|
|
-- been initiated by local device on ATM uplink interface
|
|
-- towards remote ATM equipment, by sending OAM cells."
|
|
-- ::= { radSysAtmEvents 15 }
|
|
|
|
|
|
-- VP Layer Traps
|
|
|
|
-- atmVplVpi have MAX-ACCESS "not-accessible"
|
|
-- and cannot be referenced from NOTIFICATION-TYPE clause
|
|
-- in SMIV2 so they where removed from following caluses.
|
|
-- Dovi Korngut (28/6/00).
|
|
|
|
atmAceAlarmVpContinuityLoss NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Loss of Continuity Check on a VP Connection."
|
|
::= { radSysAtmEvents 40 }
|
|
|
|
|
|
atmAceAlarmVpAISReception NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates AIS Reception on a VP Connection."
|
|
::= { radSysAtmEvents 41 }
|
|
|
|
|
|
atmAceAlarmVpRDIReception NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates RDI Reception on a VP Connection."
|
|
::= { radSysAtmEvents 42 }
|
|
|
|
|
|
atmAceAlarmVpErroredCells NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Errored Cells on a VP Connection reported by PM."
|
|
::= { radSysAtmEvents 43 }
|
|
|
|
|
|
atmAceAlarmVpLostCells NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Lost Cells on a VP Connection reported by PM."
|
|
::= { radSysAtmEvents 44 }
|
|
|
|
|
|
atmAceAlarmVpMisinsertedCells NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Misinserted Cells on a VP Connection
|
|
reported by PM."
|
|
::= { radSysAtmEvents 45 }
|
|
|
|
atmAceAlarmVpUAS NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon UAS start or end per VP."
|
|
::= { radSysAtmEvents 46 }
|
|
|
|
atmAceAlarmVpLoopback NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon OAM LoopBack fail status per VP."
|
|
::= { radSysAtmEvents 47 }
|
|
|
|
atmAceAlarmVpGCRAViolation NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates GCRA violation on a VP Connection
|
|
reported by UPC device."
|
|
::= { radSysAtmEvents 48 }
|
|
|
|
|
|
-- VC Layer Traps
|
|
|
|
-- atmVclVpi and atmVclVci have MAX-ACCESS "not-accessible"
|
|
-- and cannot be referenced from NOTIFICATION-TYPE clause
|
|
-- in SMIV2 so they where removed from following caluses.
|
|
-- Dovi Korngut (28/6/00).
|
|
|
|
atmAceAlarmVcContinuityLoss NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Loss of Continuity Check on a VC Connection."
|
|
::= { radSysAtmEvents 56 }
|
|
|
|
atmAceAlarmVcAISReception NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates AIS Reception on a VC."
|
|
::= { radSysAtmEvents 57 }
|
|
|
|
atmAceAlarmVcRDIReception NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates RDI Reception on a VC Connection."
|
|
::= { radSysAtmEvents 58 }
|
|
|
|
atmAceAlarmVcErroredCells NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Errored Cells on a VC Connection reported by PM."
|
|
::= { radSysAtmEvents 59 }
|
|
|
|
atmAceAlarmVcLostCells NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Lost Cells on a VC Connection reported by PM."
|
|
::= { radSysAtmEvents 60 }
|
|
|
|
atmAceAlarmVcMisinsertedCells NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Misinserted Cells on a VC Connection reported
|
|
by PM."
|
|
::= { radSysAtmEvents 61 }
|
|
|
|
atmAceAlarmVcUnexpectedCell NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates an unexpected cell from user or network port."
|
|
::= { radSysAtmEvents 62 }
|
|
|
|
atmAceAlarmVcUAS NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon UAS start or end per VC."
|
|
::= { radSysAtmEvents 63 }
|
|
|
|
atmAceAlarmVcLoopback NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon OAM LoopBack fail status per VC."
|
|
::= { radSysAtmEvents 64 }
|
|
|
|
atmAceAlarmVcGCRAViolation NOTIFICATION-TYPE
|
|
OBJECTS { alarmSeverity, alarmState, ifAlias }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates GCRA violation on a VC Connection
|
|
reported by UPC device."
|
|
::= { radSysAtmEvents 65 }
|
|
|
|
-- number 80 and up are saved for IMA traps
|
|
|
|
-- END
|
|
|
|
|
|
|
|
-- SENDING OAM VC-AIS CELLS ??
|
|
-- This message appears when the LA-110 starts/stop
|
|
-- transmitting OAM cells of type VC-AIS to the
|
|
-- ATM network the alarm description
|
|
-- will be followed with the relevant VP/VC
|
|
--
|
|
|
|
-- SENDING OAM VC-RDI CELLS ???
|
|
-- This message appears when the LA-110 start/stop
|
|
-- transmitting OAM cells of type VC-RDI to the
|
|
-- ATM network the alarm description will be
|
|
-- followed with the relevant VP/VC
|
|
--
|
|
|
|
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver485\ipRouter.txt
|
|
--
|
|
|
|
|
|
--Version: 1.0
|
|
--Date: 31.01.99
|
|
--By: Ilana Schvetz
|
|
--File: ipRouter.txt
|
|
--
|
|
--Last Update: Ilana Schvetz 09/01/02
|
|
|
|
|
|
--radRouter OBJECT IDENTIFIER ::= { rad 11 }
|
|
--rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
|
|
|
|
ipRouter OBJECT IDENTIFIER ::= { rtrBridge 3 }
|
|
|
|
|
|
|
|
rtrIfIpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrIfIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Router interfaces table."
|
|
::= { ipRouter 1 }
|
|
|
|
rtrIfIpEntry OBJECT-TYPE
|
|
SYNTAX RtrIfIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in table rtrIfIpTable."
|
|
INDEX { rtrIfIp }
|
|
::= { rtrIfIpTable 1 }
|
|
|
|
RtrIfIpEntry ::=
|
|
SEQUENCE {
|
|
rtrIfIp IpAddress,
|
|
rtrIfRowStatus RowStatus,
|
|
rtrIfIpMask IpAddress,
|
|
rtrIfIndex Integer32,
|
|
rtrIfMng INTEGER,
|
|
rtrIfVlanId VlanIndex
|
|
}
|
|
|
|
rtrIfIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address."
|
|
::= { rtrIfIpEntry 1 }
|
|
|
|
rtrIfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"."
|
|
::= { rtrIfIpEntry 2 }
|
|
|
|
rtrIfIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP mask Address."
|
|
::= { rtrIfIpEntry 3 }
|
|
|
|
rtrIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex connection, on which the IP is determined."
|
|
::= { rtrIfIpEntry 4 }
|
|
|
|
rtrIfMng OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IP interface might be determined as a management
|
|
connection (under the product limitations)."
|
|
::= { rtrIfIpEntry 5 }
|
|
|
|
rtrIfVlanId OBJECT-TYPE
|
|
SYNTAX VlanIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN ID assigned to Tagged frames transmitted
|
|
from this port.
|
|
The value inserted should be a defined VLAN."
|
|
::= { rtrIfIpEntry 6 }
|
|
|
|
|
|
-- Brouter Table
|
|
|
|
brtrIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BrtrIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LAN interface table."
|
|
::= { ipRouter 2 }
|
|
|
|
brtrIfEntry OBJECT-TYPE
|
|
SYNTAX BrtrIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries of this table will be created by agent."
|
|
INDEX { brtrIfIndex }
|
|
::= { brtrIfTable 1 }
|
|
|
|
|
|
BrtrIfEntry ::=
|
|
SEQUENCE {
|
|
brtrIfIndex Integer32,
|
|
brtrIfMode INTEGER,
|
|
brtrIfMaxFrameSize Integer32
|
|
}
|
|
|
|
brtrIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the interface (LAN or ATM)."
|
|
::= { brtrIfEntry 1 }
|
|
|
|
brtrIfMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bridge (1),
|
|
router (2),
|
|
brouter (3),
|
|
off (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Connection Mode."
|
|
::= { brtrIfEntry 2 }
|
|
|
|
brtrIfMaxFrameSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frame Max Size."
|
|
::= { brtrIfEntry 3 }
|
|
|
|
|
|
|
|
rtrArpAgingTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ARP Aging Time. Applicable for a Router Mode
|
|
and for a Brouter Mode."
|
|
::= { ipRouter 3 }
|
|
|
|
-- Brouter LAN If table
|
|
|
|
|
|
brtrLanIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BrtrLanIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LAN interface table."
|
|
::= { ipRouter 4 }
|
|
|
|
brtrLanIfEntry OBJECT-TYPE
|
|
SYNTAX BrtrLanIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries of this table will be created by agent ."
|
|
INDEX { brtrLanIfIndex }
|
|
::= { brtrLanIfTable 1 }
|
|
|
|
|
|
BrtrLanIfEntry ::=
|
|
SEQUENCE {
|
|
brtrLanIfIndex Integer32,
|
|
brtrLanIpAddress IpAddress,
|
|
brtrLanIpMask IpAddress,
|
|
brtrLanMaxRateEnable INTEGER,
|
|
brtrLanMaxRate Integer32,
|
|
brtrLanMng INTEGER,
|
|
brtrLanDefaultRouter IpAddress
|
|
}
|
|
|
|
brtrLanIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the LAN entity (physical interface)."
|
|
::= { brtrLanIfEntry 1 }
|
|
|
|
brtrLanIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Host IP address. Applicable for bridge mode connection only."
|
|
::= { brtrLanIfEntry 2 }
|
|
|
|
brtrLanIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Host IP Mask. Applicable for bridge mode connection only."
|
|
::= { brtrLanIfEntry 3 }
|
|
|
|
|
|
brtrLanMaxRateEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the HW ability of the LAN
|
|
card according to HW."
|
|
::= { brtrLanIfEntry 4 }
|
|
|
|
brtrLanMaxRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Max Rate."
|
|
::= { brtrLanIfEntry 5 }
|
|
|
|
brtrLanMng OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no (1),
|
|
yes (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IP interface might be determined as a management
|
|
connection (under the product limitations)."
|
|
::= { brtrLanIfEntry 6 }
|
|
|
|
brtrLanDefaultRouter OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Router's (Gateway's) IP Address.
|
|
For each LAN interface there may be a different Default Router."
|
|
::= { brtrLanIfEntry 7 }
|
|
|
|
|
|
|
|
rtrIsdnIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrIsdnIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains ISDN parameters that do not appear in the standard MIBs."
|
|
::= { ipRouter 5 }
|
|
|
|
rtrIsdnIfEntry OBJECT-TYPE
|
|
SYNTAX RtrIsdnIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries for ISDN parameters that do not appear in the standard MIBs."
|
|
AUGMENTS { isdnSignalingEntry }
|
|
-- INDEX { isdnSignalingIndex }
|
|
::= { rtrIsdnIfTable 1 }
|
|
|
|
|
|
RtrIsdnIfEntry ::=
|
|
SEQUENCE {
|
|
rtrIsdnIfMinNumBchans Integer32,
|
|
rtrIsdnIfMaxNumBchans Integer32
|
|
}
|
|
|
|
rtrIsdnIfMinNumBchans OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum number of B channels that the ISDN Dialer of the router will use
|
|
for Dialing out.
|
|
This parameter will be used for the BOD (Bandwidth On Demand) feature.
|
|
Dial up on B channels is according to the need of bandwidth for router
|
|
data transfer. Voice calls have a higher priority than router data.
|
|
In case of few time slots the voice calls will cause disconnection of
|
|
data channels up to the limit of minimum number of B channels."
|
|
::= { rtrIsdnIfEntry 1 }
|
|
|
|
rtrIsdnIfMaxNumBchans OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of B channels that the ISDN Dialer of the router will use
|
|
for Dialing out.
|
|
This parameter will be used for the BOD (Bandwidth On Demand) feature.
|
|
Dial up on B channels is according to the need of bandwidth for router
|
|
data transfer. Voice calls have a higher priority than router data.
|
|
No more than MAX B channels will be used by the ISDN dialer."
|
|
::= {rtrIsdnIfEntry 2 }
|
|
|
|
|
|
rtrLcrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrLcrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Least Cost Routing Table.
|
|
The user will be able to set a prefix for an outgoing number
|
|
that arrives with a predefined prefix in order to redirect
|
|
the number for the LCR process to be achieved."
|
|
::= { ipRouter 6 }
|
|
|
|
rtrLcrEntry OBJECT-TYPE
|
|
SYNTAX RtrLcrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Least Cost Routing Entry."
|
|
INDEX { ifIndex, rtrLcrOutIfIndex }
|
|
::= { rtrLcrTable 1 }
|
|
|
|
|
|
RtrLcrEntry ::=
|
|
SEQUENCE {
|
|
rtrLcrOutIfIndex InterfaceIndex,
|
|
rtrLcrRowStatus RowStatus,
|
|
rtrLcrInPrefix DisplayString,
|
|
rtrLcrOutPrefix DisplayString
|
|
}
|
|
|
|
rtrLcrOutIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outgoing interface Number of the current route.
|
|
The incoming interface number is the value of ifIndex."
|
|
::= { rtrLcrEntry 1 }
|
|
|
|
rtrLcrRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Status for adding/destroying rows."
|
|
::= { rtrLcrEntry 2 }
|
|
|
|
rtrLcrInPrefix OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This prefix is part of the called number existing in the incoming packet."
|
|
::= {rtrLcrEntry 3 }
|
|
|
|
rtrLcrOutPrefix OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This prefix will be inserted into the outgoing packet."
|
|
::= {rtrLcrEntry 4 }
|
|
|
|
|
|
|
|
|
|
--radRouter OBJECT IDENTIFIER ::= { rad 11 }
|
|
|
|
multicastGen OBJECT IDENTIFIER ::= { radRouter 8 } -- General Multicast Parameters
|
|
|
|
multicastMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (2),
|
|
wanToLan (3),
|
|
wanToLanIgmp (4),
|
|
lanToWan (5),
|
|
bidirectional(6),
|
|
transparent(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"According to this mode the packets will be forwarded.
|
|
If disable (2) is selected, there will be no multicast."
|
|
::= { multicastGen 1 }
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver485\clksrc.txt
|
|
--
|
|
-- file : clksrc.txt
|
|
--
|
|
-- available for ACE2002. This file is part of dxc.txt.
|
|
--Version: 1.0
|
|
--Date: 9.7.00
|
|
--By: Ilana Schvetz
|
|
--File: v:\doc\rdv\mib\ver485\clksrc.txt
|
|
|
|
--Last Update: 25.11.01 by Ilana
|
|
-- Copyright 1997 RAD Data Communications, Ltd.
|
|
-- All Rights Reserved.
|
|
|
|
|
|
dacsMux OBJECT IDENTIFIER ::= {radWan 3}
|
|
|
|
systemDacsMux OBJECT IDENTIFIER ::= {dacsMux 1}
|
|
|
|
sysStatus OBJECT IDENTIFIER ::= {systemDacsMux 3}
|
|
sysConfig OBJECT IDENTIFIER ::= {systemDacsMux 6}
|
|
|
|
|
|
sysSClkSrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master (1),
|
|
fallback(2),
|
|
internal(3),
|
|
ml (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the source of the system clock."
|
|
::= { sysStatus 7 }
|
|
|
|
|
|
--System Configuration Parameters
|
|
|
|
sysCClkSrcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysCClkSrcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the entries of this table are identical (have the
|
|
same value) for all the configurations (1..255) except
|
|
the TmpCnfg.
|
|
The write operation into the Table Objects is valid only
|
|
for the TmpCnfg entry."
|
|
::= { sysConfig 1}
|
|
|
|
sysCClkSrcEntry OBJECT-TYPE
|
|
SYNTAX SysCClkSrcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {sysCClkCnfgIdx, sysCClkSrcIdx}
|
|
::= { sysCClkSrcTable 1}
|
|
|
|
SysCClkSrcEntry ::=
|
|
SEQUENCE {
|
|
sysCClkCnfgIdx Integer32,
|
|
sysCClkSrcIdx INTEGER,
|
|
sysCClkSrcMode INTEGER,
|
|
sysCClkSrcPrt Integer32,
|
|
sysCClkStationFreq INTEGER,
|
|
sysCClkRevertiveTimeout Integer32
|
|
}
|
|
|
|
sysCClkCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..255) being
|
|
accessed ; Idx of 255 relates to the TmpCnfg."
|
|
::= { sysCClkSrcEntry 1}
|
|
-- In phase I of DXC and FCD, only the values 1 (Cnfg1) and 255
|
|
-- (temp) are valid.
|
|
|
|
sysCClkSrcIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master (1),
|
|
fallback (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index in the table. There are only two entries in the
|
|
table.
|
|
master - refers Master clock parameters
|
|
fallback - refers Fallback clock parameters"
|
|
::= { sysCClkSrcEntry 2}
|
|
|
|
sysCClkSrcMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
internal (2),
|
|
rxClk (3),
|
|
station (4),
|
|
lbt (5),
|
|
ntr (6),
|
|
adaptive (7),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the source the nodal timing is
|
|
locked to.
|
|
none - is an invalid option for Master clock.
|
|
internal - is an invalid option for Fallback clock .
|
|
station - is an invalid option for a stand-alone unit.
|
|
lbt - loop-back timing
|
|
ntr - A system locked reference clock
|
|
adaptive - clcok locking is achieved by altering the clock
|
|
according to the data load
|
|
notApplicable - for ML source of Kmux or ML Timing
|
|
combinations when Master/Fallback clock are
|
|
not applicable."
|
|
::= { sysCClkSrcEntry 3}
|
|
|
|
|
|
sysCClkSrcPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is valid only when working in rxClk mode.
|
|
|
|
For ACE2002 in case of invalid entry the return value
|
|
will be 0.
|
|
For other products in case of invalid entry the return
|
|
value will be 9999.
|
|
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside,
|
|
SP.
|
|
* The SP ports will be numbered as follows:
|
|
- SP port 1 : 1
|
|
- SP port 2 : 2
|
|
For external ports the convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
For internal ports the convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
|
|
For Kmux, the port will be according to : Slot*100+Ch.
|
|
|
|
For ACE2002 and LA140, the port will be ifIndex."
|
|
::= { sysCClkSrcEntry 4}
|
|
|
|
|
|
sysCClkStationFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
f1544Khz (2),
|
|
f2048Khz (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the frequency of the station clock
|
|
when the source is 'station'.
|
|
The value will be applicable only when the sysCClkSrcMode is
|
|
'station'. "
|
|
::= { sysCClkSrcEntry 5}
|
|
|
|
sysCClkRevertiveTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time in seconds in which the system will monitor the higher
|
|
level clock source, before decision to revert to that clock.
|
|
In case the time is zero, revertive mode will be disabled."
|
|
::= { sysCClkSrcEntry 6}
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\sub_rtr.txt
|
|
--
|
|
-- version 4.95
|
|
-- file :sub_rtr.txt
|
|
--
|
|
--RTR-MIB
|
|
--
|
|
--Last update: 30-Apr-2003 by Shay Harari
|
|
|
|
|
|
--radRouter OBJECT IDENTIFIER ::= { rad 11 } RAD Router
|
|
|
|
-- ************************************************
|
|
-- Interfaces Group
|
|
-- Link Layer (layer 2) Configuration MIB
|
|
-- ************************************************
|
|
|
|
-- The following MIB group is used by the Management/Configuration
|
|
-- station to configure the device interfaces,
|
|
-- physicals as well as virtuals.
|
|
-- Each entry in the rtrDynamicIfConfigTable should have one of
|
|
-- the extended rtType.
|
|
-- It will also have a corresponding entry in the standard iftable.
|
|
-- The implementation uses these inputs to build the interface
|
|
-- layer of the device. The output is reflected in the
|
|
-- ifTable and ifStackTable which are implementation dependent.
|
|
|
|
|
|
rtrInterfaces OBJECT IDENTIFIER ::= { radRouter 1 }
|
|
|
|
RtrIfConfigTYPE ::= INTEGER
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This type defines what type of sub-layer is used
|
|
-- in each entr of rtrDynamicIfConfigTable.
|
|
-- It should contain values from IANAifType
|
|
-- type for standard sub-layer, and values (starting from 999
|
|
-- decimal) for private sub-layers.
|
|
-- The values of the ifType field in ifTable should be taken
|
|
-- from IANAifType only."
|
|
{
|
|
other(1),
|
|
ethernetLan(6), -- From IANAifType
|
|
iso88023Csmacd(7),
|
|
tokenRingLan(9),
|
|
fddi(15),
|
|
basicISDN(20),
|
|
primaryISDN(21),
|
|
propPointToPoint(22), -- rndWAN
|
|
slip(28),
|
|
ppp(23), -- From IANAifType
|
|
frameRelay(32),
|
|
rs232(33),
|
|
atm(37),
|
|
x25ple(40),
|
|
v35(45),
|
|
fastEther(62), -- Fast Ethernet (100BaseT)
|
|
fastEtherFX(69), -- Fast Ethernet (100BaseFX)
|
|
virtualNet(500),
|
|
|
|
cod(1001), -- Rad/Rnd private
|
|
backUp(1002),
|
|
dialUp(1004),
|
|
b1isdn(1010),
|
|
b2isdn(1011),
|
|
ipBcst(1020),
|
|
ipPtp(1021),
|
|
ipxRaw(1022),
|
|
ipxEtType(1023),
|
|
ipxLlcSap(1024),
|
|
ipxLlcSnap(1025),
|
|
ipxPtp(1026),
|
|
brgUnder(1027),
|
|
wanDriver(1060),
|
|
ethernetDriver(1061),
|
|
tokenRingDriver(1062),
|
|
fddiDriver (1064), -- RAD private FDDI driver
|
|
virtualLan(1080),
|
|
unknown(1100)
|
|
|
|
}
|
|
|
|
rtrConfigIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrConfigIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of configured interfaces."
|
|
::= { rtrInterfaces 1 }
|
|
|
|
rtrConfigIfEntry OBJECT-TYPE
|
|
SYNTAX RtrConfigIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry defines a configured interface."
|
|
INDEX { rtrConfigIfIndex }
|
|
::= { rtrConfigIfTable 1 }
|
|
|
|
|
|
RtrConfigIfEntry ::= SEQUENCE {
|
|
rtrConfigIfIndex
|
|
InterfaceIndex,
|
|
rtrConfigIfType
|
|
RtrIfConfigTYPE,
|
|
rtrConfigIfName
|
|
DisplayString,
|
|
rtrConfigIfStatus
|
|
RowStatus
|
|
}
|
|
|
|
rtrConfigIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the interface.
|
|
It is used as a cross reference in other system tables"
|
|
::= { rtrConfigIfEntry 1 }
|
|
|
|
rtrConfigIfType OBJECT-TYPE
|
|
SYNTAX RtrIfConfigTYPE
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the type of the specific
|
|
entry in the rtrDynamicIfConfigTable.
|
|
This field is writable only at creation time
|
|
(i.e., when value of status is underCreation)."
|
|
::= { rtrConfigIfEntry 2 }
|
|
|
|
rtrConfigIfName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable provides a logical name to a specific entry in
|
|
rtrConfigIfTable. It is also used in identifying the Driver
|
|
interfaces."
|
|
::= { rtrConfigIfEntry 3 }
|
|
|
|
rtrConfigIfStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the ConfigEntry. The choices are those
|
|
defined in SNMPv2-TC. Only: active, createAndWait, and destroy
|
|
will be used.
|
|
active - The conceptual row is available for use by the managed device.
|
|
createAndWait - A new instance of a conceptual row is desired, but
|
|
not to have it available for use by the managed device.
|
|
destroy - Delete all instances associated with an existing conceptual row."
|
|
::= { rtrConfigIfEntry 4 }
|
|
|
|
|
|
-- Router Interface Configuration Table
|
|
|
|
rtrIfCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Router Interface Configuration Table."
|
|
::= { rtrInterfaces 2 }
|
|
|
|
rtrIfCfgEntry OBJECT-TYPE
|
|
SYNTAX RtrIfCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Router Interface Configuration Table."
|
|
INDEX { rtrIfCfgIndex, rtrIfCfgIpAddress }
|
|
::= { rtrIfCfgTable 1 }
|
|
|
|
|
|
RtrIfCfgEntry ::= SEQUENCE {
|
|
rtrIfCfgIndex
|
|
Integer32,
|
|
rtrIfCfgIpAddress
|
|
IpAddress,
|
|
rtrIfCfgRowStatus
|
|
RowStatus,
|
|
rtrIfCfgIpMask
|
|
IpAddress,
|
|
rtrIfCfgIfIndex
|
|
Integer32,
|
|
rtrIfCfgType
|
|
INTEGER,
|
|
rtrIfCfgVlanId
|
|
VlanIndex
|
|
}
|
|
|
|
rtrIfCfgIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Router Interface Index.
|
|
(In some cases it will be equal to the Router Interface ifIndex)."
|
|
::= { rtrIfCfgEntry 1 }
|
|
|
|
rtrIfCfgIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address of the Router Interface."
|
|
::= { rtrIfCfgEntry 2 }
|
|
|
|
rtrIfCfgRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables the user to
|
|
create/delete entries of this table."
|
|
::= { rtrIfCfgEntry 3 }
|
|
|
|
rtrIfCfgIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Mask Address Router Interface."
|
|
::= { rtrIfCfgEntry 4 }
|
|
|
|
rtrIfCfgIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ifIndex of the device interface connected
|
|
to this Router Interface."
|
|
::= { rtrIfCfgEntry 5 }
|
|
|
|
rtrIfCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
atm (2),
|
|
lis (3),
|
|
ethernet(4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Router Interface Type.
|
|
atm - ATM router interface
|
|
lis - Logical IP Subnet router interface.
|
|
ethernet - Ethernet router interface. "
|
|
::= { rtrIfCfgEntry 6 }
|
|
|
|
rtrIfCfgVlanId OBJECT-TYPE
|
|
SYNTAX VlanIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN ID assigned to Tagged frames transmitted
|
|
from this Router Interface.
|
|
The value inserted should be a defined VLAN."
|
|
::= { rtrIfCfgEntry 7 }
|
|
|
|
|
|
|
|
-- **************** Interfaces Groups End *******************
|
|
|
|
|
|
-- **************** IP Groups ******************
|
|
|
|
-- IP Group
|
|
|
|
-- ************************************************
|
|
-- IP Interface Configuration MIB
|
|
-- ************************************************
|
|
|
|
|
|
ipSpec OBJECT IDENTIFIER ::= { radRouter 2 }
|
|
|
|
rtrIpAddrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrIpAddrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is parralel to MIB II IpAddrTable, and is used to
|
|
add/delete entries to/from that table. In addition it contains
|
|
private objects."
|
|
::= { ipSpec 1 }
|
|
|
|
rtrIpAddrEntry OBJECT-TYPE
|
|
SYNTAX RtrIpAddrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The addressing information for one of this
|
|
entity's IP addresses."
|
|
INDEX {rtrIpAdEntAddr}
|
|
::= { rtrIpAddrTable 1 }
|
|
|
|
RtrIpAddrEntry ::= SEQUENCE {
|
|
rtrIpAdEntAddr IpAddress,
|
|
rtrIpAdEntIfIndex Integer32,
|
|
rtrIpAdEntNetMask IpAddress,
|
|
rtrIpAdEntForwardIpBroadcast INTEGER,
|
|
rtrIpAdEntBackupAddr IpAddress,
|
|
rtrIpAdEntStatus RowStatus
|
|
}
|
|
|
|
rtrIpAdEntAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address to which this entry's addressing
|
|
information pertains."
|
|
::= { rtrIpAddrEntry 1 }
|
|
|
|
rtrIpAdEntIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index value which uniquely identifies the
|
|
interface to which this entry is applicable. The
|
|
interface identified by a particular value of this
|
|
index is the same interface as identified by the
|
|
same value of ifIndex."
|
|
::= { rtrIpAddrEntry 2 }
|
|
|
|
rtrIpAdEntNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The subnet mask associated with the IP address of
|
|
this entry. The value of the mask is an IP
|
|
address with all the network bits set to 1 and all
|
|
the hosts bits set to 0."
|
|
::= { rtrIpAddrEntry 3 }
|
|
|
|
rtrIpAdEntForwardIpBroadcast OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This variable controls forwarding of IP (sub)net-directed
|
|
broadcasts destined for an attached sub(net). "
|
|
DEFVAL { enable }
|
|
::= { rtrIpAddrEntry 4 }
|
|
|
|
rtrIpAdEntBackupAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" "
|
|
::= { rtrIpAddrEntry 5 }
|
|
|
|
rtrIpAdEntStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The Status variable is used to create and destroy a Ip Addresses."
|
|
::= { rtrIpAddrEntry 6 }
|
|
|
|
icmpSpec OBJECT IDENTIFIER ::= { ipSpec 2 }
|
|
|
|
rtrIcmpGenErrMsgEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable controlls the ability to generate ICMP error messages"
|
|
DEFVAL { enable }
|
|
::= { icmpSpec 1 }
|
|
|
|
rtrIcmpRdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrIcmpRdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains ICMP Router Discovery parameters
|
|
configurated per IP interface."
|
|
::= {icmpSpec 2}
|
|
|
|
rtrIcmpRdEntry OBJECT-TYPE
|
|
SYNTAX RtrIcmpRdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ICMP parameters configurated for IP interface."
|
|
INDEX {rtrIcmpRdIpAddr}
|
|
::= {rtrIcmpRdTable 1}
|
|
|
|
RtrIcmpRdEntry ::= SEQUENCE {
|
|
rtrIcmpRdIpAddr IpAddress,
|
|
rtrIcmpRdIpAdvertAddr IpAddress,
|
|
rtrIcmpRdMaxAdvertInterval Integer32,
|
|
rtrIcmpRdMinAdvertInterval Integer32,
|
|
rtrIcmpRdAdvertLifetime Integer32,
|
|
rtrIcmpRdAdvertise INTEGER,
|
|
rtrIcmpRdPreferenceLevel Integer32,
|
|
rtrIcmpRdEntStatus Integer32
|
|
}
|
|
|
|
rtrIcmpRdIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address to which this entry's information pertains."
|
|
::= {rtrIcmpRdEntry 1}
|
|
|
|
rtrIcmpRdIpAdvertAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The IP destination address to be used for multicast
|
|
Router Advertisements sent from the interface. The
|
|
only permissible values are the all-systems multicast
|
|
address, 224.0.0.1, or the limited-broadcast address,
|
|
255.255.255.255."
|
|
-- DEFVAL {224.0.0.1}
|
|
::= {rtrIcmpRdEntry 2}
|
|
|
|
rtrIcmpRdMaxAdvertInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (4..1800)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum time allowed between sending multicast
|
|
Router Advertisements from the interface, in seconds.
|
|
Must be no less than 4 seconds and no greater than 1800
|
|
seconds."
|
|
DEFVAL {600}
|
|
::= {rtrIcmpRdEntry 3}
|
|
|
|
rtrIcmpRdMinAdvertInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (3..1800)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum time allowed between sending unsolicited
|
|
multicast Router Advertisements from the interface, in
|
|
seconds. Must be no less than 3 seconds and no greater
|
|
than rtrIcmpRdMaxAdvertInterval.
|
|
Default: 0.75 * rtrIcmpRdMaxAdvertInterval."
|
|
::= {rtrIcmpRdEntry 4}
|
|
|
|
rtrIcmpRdAdvertLifetime OBJECT-TYPE
|
|
SYNTAX Integer32 (4..9000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum length of time that the advertised addresses
|
|
are to be considered as valid. Must be no less than
|
|
rtrIcmpRdMaxAdvertInterval and no greater than 9000 seconds.
|
|
Default: 3 * rtrIcmpRdMaxAdvertInterval."
|
|
::= {rtrIcmpRdEntry 5}
|
|
|
|
rtrIcmpRdAdvertise OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A flag indicating whether or not the address is to be
|
|
advertised."
|
|
DEFVAL {enable}
|
|
::= {rtrIcmpRdEntry 6}
|
|
|
|
rtrIcmpRdPreferenceLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The preferability of the address as a default router
|
|
address, relative to other router addresses on the same
|
|
subnet."
|
|
DEFVAL {0}
|
|
::= {rtrIcmpRdEntry 7}
|
|
|
|
rtrIcmpRdEntStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting of any value to this object set values of
|
|
all fields to the default values."
|
|
::= {rtrIcmpRdEntry 8}
|
|
|
|
|
|
rip2Spec OBJECT IDENTIFIER ::= { ipSpec 3 }
|
|
|
|
rtrRip2IfConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrRip2IfConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is an extension of rip2IfConfTable (RFC 1724 ,RIP 2).
|
|
It means that every time somebody creates/destroys a row in the
|
|
rip2IfConfTable, the same row should be automatically created/destroyed
|
|
in this table."
|
|
::= { rip2Spec 1 }
|
|
|
|
rtrRip2IfConfEntry OBJECT-TYPE
|
|
SYNTAX RtrRip2IfConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in table rtrRip2IfConfTable."
|
|
INDEX { rtrRip2IfConfAddress }
|
|
::= { rtrRip2IfConfTable 1 }
|
|
|
|
RtrRip2IfConfEntry ::= SEQUENCE {
|
|
rtrRip2IfConfAddress IpAddress,
|
|
rtrRip2IfConfVirtualDis Integer32,
|
|
rtrRip2IfConfAutoSend INTEGER
|
|
}
|
|
|
|
rtrRip2IfConfAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The IP Address of this system on the indicated subnet. "
|
|
::= { rtrRip2IfConfEntry 1 }
|
|
|
|
rtrRip2IfConfVirtualDis OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This variable defines the virtual number of hops assigned to
|
|
the interface specified by rtrIfIpAddrIndex. This enables
|
|
fine-tuning of the RIP routing algorithm."
|
|
DEFVAL { 1 }
|
|
::= { rtrRip2IfConfEntry 2 }
|
|
|
|
rtrRip2IfConfAutoSend OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"When set to enable only the default route is sent through
|
|
the interface. When set to disable, regular RIPs are sent."
|
|
DEFVAL { disable }
|
|
::= { rtrRip2IfConfEntry 3 }
|
|
|
|
|
|
arpSpec OBJECT IDENTIFIER ::= { ipSpec 4 }
|
|
|
|
rtrArpDeleteTable OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to any not-null value has the effect of deleting
|
|
all entries of the ARP table."
|
|
::= { arpSpec 1 }
|
|
|
|
rtrArpInactiveTimeOut OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable defines the maximum time period (in second) that can
|
|
pass between ARP requests concerning an entry in the ARP table.
|
|
After this time period, the entry is deleted from the table."
|
|
DEFVAL { 60000 }
|
|
::= { arpSpec 2 }
|
|
|
|
rtrArpProxy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When ARP Proxy is enabled, the router can respond to
|
|
ARP requests for nodes located on a different sub-net,
|
|
provided they are it its network table. The router responds
|
|
with its own MAC address.
|
|
When ARP Proxy is disabled, the router responds only
|
|
to ARP requests for its own IP addresses."
|
|
DEFVAL { disable }
|
|
::= { arpSpec 3 }
|
|
|
|
|
|
-- ****************************************
|
|
-- NAT Network Address Translation
|
|
-- *****************************************
|
|
|
|
rtrNat OBJECT IDENTIFIER ::= { ipSpec 5 }
|
|
|
|
rtrNatIfConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrNatIfConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of interfaces which require separate NAT configuration."
|
|
::= {rtrNat 1}
|
|
|
|
rtrNatIfConfEntry OBJECT-TYPE
|
|
SYNTAX RtrNatIfConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A single routing domain in a single subnet."
|
|
INDEX { ifIndex, rtrNatIfVirtualAddress, rtrNatIfVirtualMask }
|
|
::= { rtrNatIfConfTable 1 }
|
|
|
|
|
|
RtrNatIfConfEntry ::=
|
|
SEQUENCE {
|
|
rtrNatIfVirtualAddress IpAddress,
|
|
rtrNatIfVirtualMask IpAddress,
|
|
rtrNatIfConfStatus RowStatus,
|
|
rtrNatIfRealAddress IpAddress,
|
|
rtrNatIfRealMask IpAddress,
|
|
rtrNatIfType INTEGER
|
|
}
|
|
|
|
|
|
rtrNatIfVirtualAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Address of the virtual subnet to be translated by the 'NAT box'
|
|
attached to this interface."
|
|
::= { rtrNatIfConfEntry 1 }
|
|
|
|
rtrNatIfVirtualMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The subnet Mask of the virtual subnet. "
|
|
::= { rtrNatIfConfEntry 2 }
|
|
|
|
rtrNatIfConfStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing 'destroy' has the effect of deleting this interface."
|
|
::= { rtrNatIfConfEntry 3 }
|
|
|
|
rtrNatIfRealAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The IP Address of the real subnet which is used by 'NAT box' for translation."
|
|
::= { rtrNatIfConfEntry 4 }
|
|
|
|
rtrNatIfRealMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The subnet Mask of the real subnet."
|
|
::= { rtrNatIfConfEntry 5 }
|
|
|
|
rtrNatIfType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static (1),
|
|
dynamic (2),
|
|
pat (3),
|
|
transparent (4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NAT type.
|
|
|
|
static - Translate a specific virtual IP network to a specific real IP
|
|
network. TCP, UDP and ICMP sessions originated both in real and
|
|
virtual networks will be translated.
|
|
dynamic - (Concurrent) Translate real IP network to larger or equal virtual
|
|
IP network. TCP, UDP and ICMP sessions originated in virtual
|
|
networks only can be translated and sessions originated in real
|
|
networks will be rejected. A session that starts in the NAT system
|
|
will be active until there will be no traffic for aging timeout
|
|
period.
|
|
pat - (Port Address Translation/ Single IP).
|
|
Translate one real IP address to virtual IP network. TCP, UDP and
|
|
ICMP sessions originated in virtual network only can be translated,
|
|
sessions originated in real network will be rejected. A session
|
|
that starts in the NAT system will be active until there will be no
|
|
traffic for aging timeout period.
|
|
transparent - In transparent mode all frames belonging to the defined IP
|
|
network will be forwarded with no translation: virtual = real."
|
|
::= { rtrNatIfConfEntry 6 }
|
|
|
|
|
|
-- *************************************
|
|
-- Port Address Translation
|
|
-- *************************************
|
|
|
|
rtrPatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrPatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port Address Translation (PAT - single IP NAT) configuration Table."
|
|
::= {rtrNat 2}
|
|
|
|
rtrPatEntry OBJECT-TYPE
|
|
SYNTAX RtrPatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describe unique mapping between real IP address,
|
|
range of ports and protocol, to local (virtual) IP address.
|
|
Ports are used in the TCP (rfc793) to name the ends of logical
|
|
connections which carry long term conversations.
|
|
For the purpose of providing services to unknown callers,
|
|
a service contact port is defined. "
|
|
INDEX { rtrPatIdx }
|
|
::= { rtrPatTable 1 }
|
|
|
|
RtrPatEntry ::=
|
|
SEQUENCE {
|
|
rtrPatIdx Integer32,
|
|
rtrPatRealAddress IpAddress,
|
|
rtrPatVirtualAddress IpAddress,
|
|
rtrPatLowestPort Integer32,
|
|
rtrPatHighestPort Integer32,
|
|
rtrPatProtocol INTEGER,
|
|
rtrPatStatus RowStatus
|
|
}
|
|
|
|
rtrPatIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Running index for PAT table."
|
|
::= { rtrPatEntry 1 }
|
|
|
|
rtrPatRealAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The real IP Address used for translation "
|
|
::= { rtrPatEntry 2 }
|
|
|
|
rtrPatVirtualAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The virtual IP Address used for translation"
|
|
::= { rtrPatEntry 3 }
|
|
|
|
rtrPatLowestPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lowest Port number for this PAT entry "
|
|
::= { rtrPatEntry 4 }
|
|
|
|
rtrPatHighestPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Highest Port number for this PAT entry "
|
|
::= { rtrPatEntry 5 }
|
|
|
|
rtrPatProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tcp (6),
|
|
udp (17)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Protocol selected.
|
|
This Protocol and port range (lowest port - highest port)
|
|
define the application (FTP, Telnet, SMTP etc.).
|
|
Protocol enumaration numbers correspond to
|
|
IP header 'protocol' field "
|
|
::= { rtrPatEntry 6 }
|
|
|
|
rtrPatStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables creating and deleting
|
|
entries of the table."
|
|
::= { rtrPatEntry 7 }
|
|
|
|
|
|
|
|
-- ************************************************
|
|
-- FACS MIB
|
|
-- ************************************************
|
|
|
|
|
|
rtrFACS OBJECT IDENTIFIER ::= { radRouter 5 }
|
|
|
|
rtrFACSDefaultAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
block(1),
|
|
forward(2),
|
|
blockAndReport(129)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to define the default action for the device, when no
|
|
FACS statements applicable to a given frame are defined."
|
|
|
|
-- DEFVAL { 1 }
|
|
::= { rtrFACS 1 }
|
|
|
|
rtrFACSActTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrFACSActEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of FACS action."
|
|
::= { rtrFACS 2 }
|
|
|
|
rtrFACSActEntry OBJECT-TYPE
|
|
SYNTAX RtrFACSActEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each rtrFACSActEntry consist of the following parameters"
|
|
INDEX {rtrFACSActType,
|
|
rtrFACSActIfIndex}
|
|
::= { rtrFACSActTable 1 }
|
|
|
|
RtrFACSActEntry ::= SEQUENCE {
|
|
rtrFACSActType INTEGER,
|
|
rtrFACSActIfIndex Integer32,
|
|
rtrFACSAction INTEGER,
|
|
rtrFACSActiveDB INTEGER
|
|
}
|
|
|
|
rtrFACSActType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tx(1),
|
|
rx(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates on which FACS Table the FACS
|
|
action will preform."
|
|
::= { rtrFACSActEntry 1 }
|
|
|
|
rtrFACSActIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface to which this FACS entry is applicable."
|
|
::= { rtrFACSActEntry 2 }
|
|
|
|
rtrFACSAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
eraseIP(2),
|
|
eraseDECnet(3),
|
|
eraseIPX(4),
|
|
eraseBrg(5),
|
|
replaceIP(6),
|
|
replaceIPX(8),
|
|
replaceBrg(9),
|
|
backupIP(10),
|
|
backupIPX(12),
|
|
backupBrg(13)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The management station that sends a SET request for one of these actions
|
|
with indexes rtrFACSType and rtrFACSIfIndex defines the type and the
|
|
interface Id for which all FACS statements are to be erased.
|
|
If no interface or no type is specified, all FACS statements for a
|
|
protocol are erased."
|
|
-- DEFVAL { 1 }
|
|
::= { rtrFACSActEntry 3 }
|
|
|
|
rtrFACSActiveDB OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(1),
|
|
temporary(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter will point on which Facs DataBase the SNMP agent
|
|
read. The Active dataBase is Read Only. The user may change FACS
|
|
statements in the temporary DataBase and then write it to the
|
|
Active DB."
|
|
::= { rtrFACSActEntry 4}
|
|
|
|
rtrFACSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrFACSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of FACS statment."
|
|
::= { rtrFACS 3 }
|
|
|
|
rtrFACSEntry OBJECT-TYPE
|
|
SYNTAX RtrFACSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each FACS statment consists of the following parameters"
|
|
INDEX {rtrFACSIfIndex,
|
|
rtrFACSProtocolType,
|
|
rtrFACSType,
|
|
rtrFACSIndex }
|
|
::= { rtrFACSTable 1 }
|
|
|
|
RtrFACSEntry ::= SEQUENCE {
|
|
rtrFACSIfIndex Integer32,
|
|
rtrFACSProtocolType INTEGER,
|
|
rtrFACSType INTEGER,
|
|
rtrFACSIndex Integer32,
|
|
rtrFACSSrcAdd OCTET STRING ,
|
|
rtrFACSSrcAddMask OCTET STRING,
|
|
rtrFACSDesAdd OCTET STRING,
|
|
rtrFACSDesAddMask OCTET STRING,
|
|
rtrFACSOperation INTEGER,
|
|
rtrFACSNetFiltering INTEGER,
|
|
rtrFACSSocketNum Integer32,
|
|
rtrFACSMask1Id Integer32,
|
|
rtrFACSMask2Id Integer32,
|
|
rtrFACSStatus INTEGER
|
|
}
|
|
|
|
rtrFACSIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface to which this FACS entry is applicable.
|
|
For applications this variables is always 0."
|
|
::= { rtrFACSEntry 1 }
|
|
|
|
rtrFACSProtocolType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
ip(1),
|
|
ipx(2),
|
|
dec(3),
|
|
bridge(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter define the protocol the Security Access Control
|
|
is applicable."
|
|
::= { rtrFACSEntry 2 }
|
|
|
|
rtrFACSType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tx(1),
|
|
rx(2),
|
|
cod(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The Mode of in which this FACS statement operates.
|
|
For applications this variable is always rx(2)."
|
|
::= { rtrFACSEntry 3 }
|
|
|
|
rtrFACSIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index to the FACS Table. "
|
|
::= { rtrFACSEntry 4 }
|
|
|
|
rtrFACSSrcAdd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of the octet string will be according to the protocol type
|
|
defined in rtrFACSProtocolType."
|
|
::= { rtrFACSEntry 5 }
|
|
|
|
rtrFACSSrcAddMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source-address mask ."
|
|
::= { rtrFACSEntry 6 }
|
|
|
|
rtrFACSDesAdd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination-address The size of the octet string will be according to the
|
|
protocol type define in rtrFACSProtocolType ."
|
|
::= { rtrFACSEntry 7 }
|
|
|
|
|
|
rtrFACSDesAddMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination-address mask ."
|
|
::= { rtrFACSEntry 8 }
|
|
|
|
|
|
rtrFACSOperation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
block(1),
|
|
forward(2),
|
|
permit(3), -- For Connect On demand Only
|
|
deny(4), -- For Connect On demand Only
|
|
blockAndReport(129)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"... ."
|
|
::= { rtrFACSEntry 9 }
|
|
|
|
rtrFACSNetFiltering OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
l2multicast(2), --applicable for Bridge protocol
|
|
arp(3), --applicable for ip protocol
|
|
icmp(4), --applicable for ip protocol
|
|
ip(5), --applicable for ip protocol
|
|
udp(6), --applicable for ip protocol
|
|
tcp(7), --applicable for ip protocol
|
|
decnet(8), --applicable for decnet protocol
|
|
ipx(9) --applicable for ipx protocol
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"... ."
|
|
::= { rtrFACSEntry 10 }
|
|
|
|
|
|
rtrFACSSocketNum OBJECT-TYPE --applicable for ip,ipx protocol
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Port/socket number for different applications
|
|
0 is default meaning not applicable.
|
|
none(1),
|
|
ftp(21),
|
|
telnet(23),
|
|
smtp(25),
|
|
tftp(69),
|
|
snmp(161),
|
|
snmpTrap(162),
|
|
rip(520),
|
|
sapIPX(1106),
|
|
ripIPX(1107) "
|
|
::= { rtrFACSEntry 11}
|
|
|
|
rtrFACSMask1Id OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Index into RND mask table FACS/COD Type) ."
|
|
::= { rtrFACSEntry 12}
|
|
|
|
rtrFACSMask2Id OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Index into RND mask table FACS/COD according to
|
|
the value of rtrFACSType ."
|
|
::= { rtrFACSEntry 13}
|
|
|
|
rtrFACSStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
valid(1),
|
|
createRequest(2),
|
|
underCreation(3),
|
|
invalid(4) -- logically deleted
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a table entry."
|
|
::= { rtrFACSEntry 14}
|
|
|
|
|
|
rtrFACSFrameData OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data from the frame that violated a FACS Filter."
|
|
::= { rtrFACS 4 }
|
|
|
|
-- **************** FACS Group Ends *******************
|
|
|
|
|
|
-- ************************************************
|
|
-- Bridge ports Configuration MIB
|
|
-- ************************************************
|
|
|
|
-- rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
|
|
|
|
|
|
rtrBridgePortConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrBridgePortConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of the bridge ports"
|
|
::= { rtrBridge 1 }
|
|
|
|
rtrBridgePortConfigEntry OBJECT-TYPE
|
|
SYNTAX RtrBridgePortConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry defines a bridge port "
|
|
INDEX { rtrBridgePortCIndex }
|
|
::= { rtrBridgePortConfigTable 1 }
|
|
|
|
RtrBridgePortConfigEntry ::= SEQUENCE {
|
|
rtrBridgePortCIndex
|
|
Integer32,
|
|
rtrBridgePortCIf
|
|
Integer32,
|
|
rtrBridgePortCStatus
|
|
RowStatus
|
|
}
|
|
|
|
|
|
|
|
rtrBridgePortCIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the index of the bridge port. It is the same
|
|
as 'dot1dBasePort' of the Bridge MIB."
|
|
::= {rtrBridgePortConfigEntry 1}
|
|
|
|
rtrBridgePortCIf OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The config ifIndex the bridge port is sitting on. "
|
|
::= {rtrBridgePortConfigEntry 2}
|
|
|
|
rtrBridgePortCStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the RtrBridgePortConfigEntry.
|
|
Creating and destroying the bridge port is done by this
|
|
variable."
|
|
::= {rtrBridgePortConfigEntry 3}
|
|
|
|
|
|
radRouterConfig OBJECT IDENTIFIER ::= { radRouter 9 }
|
|
|
|
|
|
-- The Router's Configuration Table
|
|
|
|
rtrConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Router's Configuration table."
|
|
::= { radRouterConfig 1 }
|
|
|
|
rtrConfigEntry OBJECT-TYPE
|
|
SYNTAX RtrConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Router's Configuration table."
|
|
INDEX { rtrConfigIndex }
|
|
::= { rtrConfigTable 1 }
|
|
|
|
RtrConfigEntry ::=
|
|
SEQUENCE {
|
|
rtrConfigIndex INTEGER,
|
|
-- 2 is NOT used
|
|
rtrConfigArpAgingTime Integer32,
|
|
-- 4 is NOT used
|
|
rtrConfigClassifierTosMask Integer32
|
|
}
|
|
|
|
rtrConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Router's Index."
|
|
::= { rtrConfigEntry 1 }
|
|
|
|
-- { rtrConfigEntry 2 } is NOT used
|
|
|
|
rtrConfigArpAgingTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ARP Aging Time."
|
|
::= { rtrConfigEntry 3 }
|
|
|
|
-- { rtrConfigEntry 4 } is NOT used
|
|
|
|
rtrConfigClassifierTosMask OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Classifier's TOS Mask,
|
|
as follows:
|
|
0x1C for DTR -- rfc795
|
|
0x1E for Cisco
|
|
0xE0 for Precedence -- rfc795
|
|
0xFC for Diffserv
|
|
Else for Manual
|
|
."
|
|
::= { rtrConfigEntry 5 }
|
|
|
|
|
|
-- { radRouterConfig 2 } is NOT used
|
|
|
|
|
|
-- The Router's Forwarding Table
|
|
|
|
rtrFwdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RtrFwdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Router's Forwarding Table."
|
|
::= { radRouterConfig 3 }
|
|
|
|
rtrFwdEntry OBJECT-TYPE
|
|
SYNTAX RtrFwdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Router's Forwarding table."
|
|
INDEX { rtrFwdIdx, rtrFwdIpAddress,
|
|
rtrFwdIpMask, rtrFwdRuleIdx }
|
|
::= { rtrFwdTable 1 }
|
|
|
|
RtrFwdEntry ::=
|
|
SEQUENCE {
|
|
rtrFwdIdx Integer32,
|
|
rtrFwdIpAddress IpAddress,
|
|
rtrFwdIpMask IpAddress,
|
|
rtrFwdRuleIdx Integer32,
|
|
rtrFwdRowStatus RowStatus,
|
|
rtrFwdNextHop IpAddress,
|
|
rtrFwdIfIndex Integer32,
|
|
rtrFwdType INTEGER,
|
|
rtrFwdProto INTEGER,
|
|
rtrFwdEthQueue Integer32,
|
|
rtrFwdMetric1 Integer32
|
|
}
|
|
|
|
rtrFwdIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Router Index."
|
|
::= { rtrFwdEntry 1 }
|
|
|
|
rtrFwdIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Destination IP Address."
|
|
::= { rtrFwdEntry 2 }
|
|
|
|
rtrFwdIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Mask IP address."
|
|
::= { rtrFwdEntry 3 }
|
|
|
|
rtrFwdRuleIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Rule's Number."
|
|
::= { rtrFwdEntry 4 }
|
|
|
|
rtrFwdRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables the user to
|
|
create/delete entries in this table.
|
|
|
|
Entry of Type rtrFwdType = staticRouting(3)
|
|
are created by the user.
|
|
Only this type of entries can be deleted by the user.
|
|
|
|
Entry of Type rtrFwdType = interface(2)
|
|
are created/deleted automatically by the Agent
|
|
when the user creates/deletes an interface of the Router."
|
|
::= { rtrFwdEntry 5 }
|
|
|
|
rtrFwdNextHop OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the IP Address of the Next Hop."
|
|
::= { rtrFwdEntry 6 }
|
|
|
|
rtrFwdIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Interface Index."
|
|
::= { rtrFwdEntry 7 }
|
|
|
|
rtrFwdType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1), -- not specified by this MIB
|
|
reject (2), -- route which discards traffic
|
|
local (3), -- local interface
|
|
remote (4) -- remote destination
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of route. Note that local(3) refers
|
|
to a route for which the next hop is the final
|
|
destination; remote(4) refers to a route for
|
|
which the next hop is not the final destina-
|
|
tion.
|
|
|
|
Routes which do not result in traffic forwarding or
|
|
rejection should not be displayed even if the
|
|
implementation keeps them stored internally.
|
|
|
|
reject (2) refers to a route which, if matched, discards
|
|
the message as unreachable. This is used in some
|
|
protocols as a means of correctly aggregating routes."
|
|
::= { rtrFwdEntry 8 }
|
|
|
|
rtrFwdProto OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1), -- not specified
|
|
local (2), -- local interface
|
|
netmgmt (3), -- static route
|
|
rip (8), -- Berkeley RIP or RIP-II
|
|
lis (41) -- Logical IP Subnet
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The routing mechanism via which this route was
|
|
learned. Inclusion of values for gateway routing
|
|
protocols is not intended to imply that
|
|
hosts should support those protocols."
|
|
::= { rtrFwdEntry 9 }
|
|
|
|
rtrFwdEthQueue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the ETH Queue number."
|
|
::= { rtrFwdEntry 10 }
|
|
|
|
rtrFwdMetric1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The primary routing metric for this route.
|
|
The semantics of this metric are determined by
|
|
the routing-protocol specified in the route's
|
|
rtrFwdProto value. If this metric is not
|
|
used, its value should be set to -1."
|
|
DEFVAL { -1 }
|
|
::= { rtrFwdEntry 11 }
|
|
|
|
|
|
-- **************** Router Bridge Port Group Ends *******************
|
|
|
|
|
|
|
|
-- Traps
|
|
|
|
rtrFACSViolation NOTIFICATION-TYPE
|
|
OBJECTS { rtrFACSFrameData, rtrFACSProtocolType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent for every violation of a FACS filter."
|
|
::= { radSysRtrEvents 1 }
|
|
|
|
rtrSwDwnLoadTrap NOTIFICATION-TYPE
|
|
OBJECTS { fileName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent after the tftp download of the software
|
|
and before the decompression and reset operations."
|
|
::= { radSysRtrEvents 2 }
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\atm\layer2.txt
|
|
--
|
|
--
|
|
-- file: v:\doc\rdv\mib\ver495\atm\layer2.txt
|
|
--
|
|
--RTR-MIB
|
|
--
|
|
--Last update: 25-Sep-2002
|
|
--By: Shay Harari
|
|
|
|
|
|
-- ************************************************
|
|
-- Link Layer (layer 2) MIB
|
|
-- ************************************************
|
|
|
|
|
|
atmLayer2 OBJECT IDENTIFIER ::= {radAtm 7}
|
|
|
|
atmLayer2XVclTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmLayer2XVclEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is an extension of VCL table, which is created
|
|
for each LAN VCC."
|
|
::= { atmLayer2 1 }
|
|
|
|
atmLayer2XVclEntry OBJECT-TYPE
|
|
SYNTAX AtmLayer2XVclEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conceptual row in atmVclTable.
|
|
This table augments the RFC2515 VCL table."
|
|
AUGMENTS { atmVclEntry }
|
|
::= { atmLayer2XVclTable 1 }
|
|
|
|
AtmLayer2XVclEntry ::= SEQUENCE {
|
|
atmLayer2XVclConnMode INTEGER,
|
|
atmLayer2XVclGroupIdx Integer32
|
|
}
|
|
|
|
atmLayer2XVclConnMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
main (1),
|
|
sub (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each valid LAN VCC is either Main or Sub.
|
|
This parameter is configured only once on creation of a LAN VCC.
|
|
It can not be changed after creation. In order to change the Mode,
|
|
user should delete the connection and create a new one.
|
|
|
|
main - A LAN VCC, which holds its own bridge port.
|
|
Bridge forwarding and Bridge learning is performed only on Main
|
|
VCCs.
|
|
For working on a transparent bridge, that doesn't perform
|
|
layer 2 priority mapping, a Main VCC should be opened, which
|
|
is the default connection Mode.
|
|
When working with layer 2 priority, a group of LAN VCCs should
|
|
be configured, where each group will be associated with only
|
|
one Main VCC.
|
|
A specific Main can not be used by more than one group.
|
|
sub - A LAN VCC is not part of the bridging mechanism.
|
|
A Sub VCC automatically inherit some general definitions from
|
|
Main VCC of its group: ATM Slot/Port and LAN Slot/Port.
|
|
Max number of Sub VCCs allowed per group is:
|
|
[Number of Priorities - 1]."
|
|
::= { atmLayer2XVclEntry 1 }
|
|
|
|
atmLayer2XVclGroupIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group identifier.
|
|
A VCC Group identifier = 0 if the VCC was not associated with a
|
|
group yet.
|
|
This value is updated according to the group identifier set by
|
|
atmLayer2GroupTable."
|
|
::= { atmLayer2XVclEntry 2 }
|
|
|
|
atmLayer2GroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmLayer2GroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains groups and their members.
|
|
A group is a bundle of VCCs, which acts as different queues.
|
|
Main and Sub VCCs should have the same ATM slot and port,
|
|
and the same LAN slot and port.
|
|
Each group contains: 1 to <number of priorities> VCCs."
|
|
::= { atmLayer2 2 }
|
|
|
|
atmLayer2GroupEntry OBJECT-TYPE
|
|
SYNTAX AtmLayer2GroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conceptual row in atmLayer2GroupTable.
|
|
The indexes: ifIndex, atmVclVpi and atmVclVci indicate
|
|
the Network ATM End-Point.
|
|
Upon a group creation, one Main VCC must be added first.
|
|
After the group was created, Sub VCCs may be added to the group."
|
|
INDEX { atmLayer2GroupIdx, ifIndex, atmVclVpi, atmVclVci }
|
|
::= { atmLayer2GroupTable 1 }
|
|
|
|
AtmLayer2GroupEntry ::= SEQUENCE {
|
|
atmLayer2GroupIdx Integer32,
|
|
atmLayer2GroupRowStatus RowStatus,
|
|
atmLayer2GroupConnMode INTEGER,
|
|
atmLayer2GroupConnPriority OCTET STRING,
|
|
atmLayer2GroupName SnmpAdminString
|
|
}
|
|
|
|
atmLayer2GroupIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group identifier.
|
|
0 is not a valid index."
|
|
::= { atmLayer2GroupEntry 1 }
|
|
|
|
atmLayer2GroupRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Creation/Deletion of rows in the table, and indication of the
|
|
entry's status."
|
|
::= {atmLayer2GroupEntry 2 }
|
|
|
|
atmLayer2GroupConnMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
main (1),
|
|
sub (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each valid LAN VCC is either Main or Sub as configured in
|
|
atmLayer2XVclTable."
|
|
::= { atmLayer2GroupEntry 3 }
|
|
|
|
atmLayer2GroupConnPriority OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is configured by atmLayer2PriorityRx from
|
|
atmLayer2PriorityTable.
|
|
Each bit in the Octet represents a specific priority as follows:
|
|
|
|
|
|
MSB 7 6 5 4 3 2 1 0 LSB -> Priorities
|
|
|____________________|
|
|
1 0 0 1 0 0 0 1 -> Value
|
|
|
|
In this example, a certain VCC has several priorities: 0, 4 and 7."
|
|
::= { atmLayer2GroupEntry 4 }
|
|
|
|
atmLayer2GroupName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (1..32))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group name. Configured by the user.
|
|
The name is unique per system.
|
|
For atmLayer2GroupIdx=0, the name will be null."
|
|
::= { atmLayer2GroupEntry 5 }
|
|
|
|
|
|
atmLayer2PriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmLayer2PriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table maps all priorities inside a group.
|
|
Several priorities might be mapped to the same VCC.
|
|
Upon priority change, the agent will update the VCCs of the
|
|
changed priority in this table, and will update -
|
|
atmLayer2GroupConnPriority parameter of both former and new owners
|
|
of the changed priority.
|
|
Changing a VCC value is actually a change of three parameters
|
|
simultaneously: atmLayer2PriorityIfIndex, atmLayer2PriorityVclVpi
|
|
and atmLayer2PriorityVclVci. Otherwise, the set will be rejected,
|
|
since there might be that such VCC doesn't exist in the specific
|
|
group."
|
|
::= { atmLayer2 3 }
|
|
|
|
atmLayer2PriorityEntry OBJECT-TYPE
|
|
SYNTAX AtmLayer2PriorityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conceptual row in atmLayer2PriorityTable.
|
|
Each entry is a Network ATM End-Point per priority.
|
|
Upon a group creation, all priorities are mapped to the Main VCC.
|
|
Number of entries per group is according to the number of
|
|
priorities enabled. (For example, for Max priorities = 8,
|
|
the agent will create 8 entries)."
|
|
INDEX { atmLayer2PriorityGroupIdx, atmLayer2PriorityRx }
|
|
::= { atmLayer2PriorityTable 1 }
|
|
|
|
AtmLayer2PriorityEntry ::= SEQUENCE {
|
|
atmLayer2PriorityGroupIdx Integer32,
|
|
atmLayer2PriorityRx INTEGER,
|
|
atmLayer2PriorityIfIndex InterfaceIndex,
|
|
atmLayer2PriorityVclVpi Integer32,
|
|
atmLayer2PriorityVclVci Integer32
|
|
}
|
|
|
|
atmLayer2PriorityGroupIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group identifier."
|
|
::= { atmLayer2PriorityEntry 1 }
|
|
|
|
atmLayer2PriorityRx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority values.
|
|
The used values are 0-7, but since this value is part of the index
|
|
of the table, and in order to avoid '0' as an index, the index syntax
|
|
is 1..8, but the real value is atmLayer2PriorityRx-1:
|
|
0 - for Low priority.
|
|
7 - for High priority."
|
|
::= { atmLayer2PriorityEntry 2 }
|
|
|
|
atmLayer2PriorityIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ATM ifIndex of the network End-Point."
|
|
::= { atmLayer2PriorityEntry 3 }
|
|
|
|
atmLayer2PriorityVclVpi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vpi of the network End-Point."
|
|
::= { atmLayer2PriorityEntry 4 }
|
|
|
|
atmLayer2PriorityVclVci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vci of the network End-Point."
|
|
::= { atmLayer2PriorityEntry 5 }
|
|
|
|
atmLayer2GroupIndexNext OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains an appropriate value to
|
|
be used for atmLayer2GroupIdx when creating
|
|
entries in the atmLayer2GroupTable. The value
|
|
0 indicates that no unassigned entries are
|
|
available. To obtain the atmLayer2GroupIdx
|
|
value for a new entry, the manager gets
|
|
the current value of this object. The next index
|
|
will be of the first unassigned entry. It will be
|
|
provided by checking the assigned entries."
|
|
::= { atmLayer2 4 }
|
|
|
|
--VLAN
|
|
atmLayer2CfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmLayer2CfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bridge configuration Table. This table supports multi-bridge
|
|
and bridge features within an ATM device."
|
|
::= { atmLayer2 5 }
|
|
|
|
atmLayer2CfgEntry OBJECT-TYPE
|
|
SYNTAX AtmLayer2CfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conceptual row in atmLayer2CfgTable.
|
|
Each entry in this table contains the bridging attributes for
|
|
both Ethernet and ATM sides.
|
|
The interface index is the Ethernet port interface.
|
|
|
|
For Ace52: this object represents the Bridge ifIndex."
|
|
INDEX { ifIndex }
|
|
::= { atmLayer2CfgTable 1 }
|
|
|
|
AtmLayer2CfgEntry ::= SEQUENCE {
|
|
atmLayer2CfgBridgingMode INTEGER,
|
|
atmLayer2CfgVlanMode INTEGER,
|
|
atmLayer2CfgAtmAcceptableFrameType INTEGER,
|
|
atmLayer2CfgAtmIngressFiltering TruthValue,
|
|
atmLayer2CfgAtmTxFrameType INTEGER,
|
|
atmLayer2CfgEthAcceptableFrameType INTEGER,
|
|
atmLayer2CfgBridgeAction INTEGER,
|
|
atmLayer2CfgLearningMode INTEGER,
|
|
atmLayer2CfgAgingTime Integer32
|
|
}
|
|
|
|
atmLayer2CfgBridgingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
accessOnly(1),
|
|
accessAndSwitching (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bridging mode can be one of the following:
|
|
ATM <> Ethernet - Bridging is between the Ethernet
|
|
port and the ATM port (there is no bridging between VCs).
|
|
ATM <> Ethernet + ATM - Bridging is done both between
|
|
the Ethernet port and the ATM port and also between VCs."
|
|
::= { atmLayer2CfgEntry 1 }
|
|
|
|
atmLayer2CfgVlanMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN Mode. Upon Mode changing, all LAN VCCs will be deleted
|
|
by the agent from all tables that include LAN VCCs."
|
|
::= { atmLayer2CfgEntry 2 }
|
|
|
|
atmLayer2CfgAtmAcceptableFrameType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
admitAll (2),
|
|
admitOnlyVlanTagged (3),
|
|
admitOnlyUnTagged (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Frame Type that will be acceptable by the VCCs that
|
|
are associated with this Ethernet port.
|
|
Frames which don't match the selected type will be discarded.
|
|
|
|
admitAll - all frames will be accepted.
|
|
admitOnlyVlanTagged - only Tagged frames will be accepted.
|
|
admitOnlyUnTagged - only unTagged frames will be accepted."
|
|
::= { atmLayer2CfgEntry 3 }
|
|
|
|
atmLayer2CfgAtmIngressFiltering OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For the VCCs that are associated with this Ethernet port,
|
|
when this is true(1) the device will discard incoming
|
|
frames for VLANs which do not include this Port in its
|
|
Member set. When false(2), the port will accept all
|
|
incoming frames."
|
|
::= { atmLayer2CfgEntry 4 }
|
|
|
|
atmLayer2CfgAtmTxFrameType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
unTagged (2),
|
|
tagged (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Frame Type that will be transmitted by the VCCs that
|
|
are associated with this Ethernet port.
|
|
|
|
unTagged - The transmitted frames will be unTagged.
|
|
tagged - The transmitted frames will be Tagged."
|
|
::= { atmLayer2CfgEntry 5 }
|
|
|
|
atmLayer2CfgEthAcceptableFrameType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
admitAll (2),
|
|
admitOnlyVlanTagged (3),
|
|
admitOnlyUnTagged (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Frame Type that this Ethernet port will accept.
|
|
(for ACE-52: the Frame Type that this Bridge will accept)
|
|
This parameter is notApplicable for atmLayer2VlanMode=disable.
|
|
Frames which don't match the selected type will be discarded.
|
|
|
|
admitAll - all frames will be accepted.
|
|
admitOnlyVlanTagged - only Tagged frames will be accepted.
|
|
admitOnlyUnTagged - only unTagged frames will be accepted."
|
|
::= { atmLayer2CfgEntry 6 }
|
|
|
|
atmLayer2CfgBridgeAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
deleteLanTable (7),
|
|
noOp (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables to perform the specified action on the
|
|
selected port."
|
|
::= { atmLayer2CfgEntry 7 }
|
|
|
|
atmLayer2CfgLearningMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
svl (1),
|
|
ivl (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the mode of the learning process of a bridge.
|
|
svl - Shared VLAN process. If an individual MAC Address is learned
|
|
in one VLAN, this information is used in forwarding decisions
|
|
taken for that address for all other VLANs.
|
|
ivl - Independent VLAN process. If an individual MAC Address is learned
|
|
in one VLAN, this information is not used in forwarding decisions
|
|
taken for that address for all other VLANs."
|
|
::= { atmLayer2CfgEntry 8 }
|
|
|
|
atmLayer2CfgAgingTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timeout period in seconds for aging out
|
|
dynamically learned forwarding information."
|
|
::= { atmLayer2CfgEntry 9 }
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver470\atm\frAtm.txt
|
|
--
|
|
--
|
|
-- file: v:\doc\rdv\mib\ver470\atm\frAtm.txt
|
|
--
|
|
--FR-ATM-IWF-X-MIB
|
|
--
|
|
--Last update: 28-Feb-2001
|
|
--By: Ilana Schvetz
|
|
|
|
|
|
--atmSuPortFr OBJECT IDENTIFIER ::= { atmSuPort 4 }
|
|
radAtmFr OBJECT IDENTIFIER ::= {radAtm 8}
|
|
|
|
frAtmIwfXConnectionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrAtmIwfXConnectionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is an extension of frAtmIwfXConnectionTable from
|
|
RFC2955."
|
|
::= { radAtmFr 1 }
|
|
|
|
frAtmIwfXConnectionEntry OBJECT-TYPE
|
|
SYNTAX FrAtmIwfXConnectionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conceptual row in frAtmIwfXConnectionTable.
|
|
This table augments the RFC2955."
|
|
AUGMENTS { frAtmIwfConnectionEntry }
|
|
::= { frAtmIwfXConnectionTable 1 }
|
|
|
|
FrAtmIwfXConnectionEntry ::= SEQUENCE {
|
|
frAtmIwfXConnMode INTEGER,
|
|
frAtmIwfXConnSscsDlci Integer32
|
|
}
|
|
|
|
frAtmIwfXConnMode OBJECT-TYPE
|
|
SYNTAX INTEGER { service(1), network(2) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FR IWF Mode.
|
|
service - Service InterWorking (FRF.8),
|
|
network - Network InterWorking (FRF.5)."
|
|
::= { frAtmIwfXConnectionEntry 1 }
|
|
|
|
frAtmIwfXConnSscsDlci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is relevant for
|
|
frAtmIwfXConnMode=network (FRF.5) only.
|
|
This parameter allow configuration of the
|
|
FR SSCS DLCI that is transferred to the
|
|
remote FR unit."
|
|
::= { frAtmIwfXConnectionEntry 2 }
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt
|
|
--
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt
|
|
--
|
|
--Last update: 19-Nov-2002 by Ilana Schvetz
|
|
|
|
|
|
-- ATM-X-MIB DEFINITIONS ::= BEGIN
|
|
--
|
|
--atmGen OBJECT IDENTIFIER ::= {radAtm 2}
|
|
|
|
--atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1}
|
|
|
|
--atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1}
|
|
|
|
-- AAL5 Virtual Channel Connection Performance Statistics
|
|
|
|
-- Table
|
|
|
|
-- This table contains the AAL5 extension
|
|
-- performance statistics of a VCC at the
|
|
-- interface associated with an AAL5 entity in an ATM
|
|
-- host or ATM switch.
|
|
|
|
aal5VccXTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Aal5VccXEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is an extension to AAL5 VCC Table."
|
|
::= { atmIfPerformance 4 }
|
|
|
|
aal5VccXEntry OBJECT-TYPE
|
|
SYNTAX Aal5VccXEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This list contains the additional AAL5 VCC
|
|
performance parameters and is indexed
|
|
by ifIndex values of AAL5 interfaces
|
|
and the associated VPI/VCI values."
|
|
AUGMENTS { aal5VccEntry }
|
|
::= { aal5VccXTable 1 }
|
|
|
|
Aal5VccXEntry ::= SEQUENCE {
|
|
aal5VccInFrames Counter32,
|
|
aal5VccOutFrames Counter32,
|
|
aal5VccUnknownProtocolFrames Counter32
|
|
}
|
|
|
|
aal5VccInFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames received via this interface."
|
|
::= { aal5VccXEntry 1 }
|
|
|
|
aal5VccOutFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of frames transmitted out of the
|
|
interface."
|
|
::= { aal5VccXEntry 2 }
|
|
|
|
aal5VccUnknownProtocolFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of frames that were discarded due to unsupported
|
|
protocol encapsulation on this VCC."
|
|
::= { aal5VccXEntry 3 }
|
|
|
|
|
|
aal5VccCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Aal5VccCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The AAL5 Current table."
|
|
::= { atmIfPerformance 5 }
|
|
|
|
aal5VccCurrentEntry OBJECT-TYPE
|
|
SYNTAX Aal5VccCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the AAL5 Current table."
|
|
INDEX { ifIndex, aal5VccVpi, aal5VccVci }
|
|
::= { aal5VccCurrentTable 1 }
|
|
|
|
Aal5VccCurrentEntry
|
|
::= SEQUENCE {
|
|
aal5VccCurrentInFrames
|
|
Gauge32,
|
|
aal5VccCurrentOutFrames
|
|
Gauge32,
|
|
aal5VccCurrentUnknownProtocolFrames
|
|
Gauge32,
|
|
aal5VccCurrentCrcErrors
|
|
Gauge32,
|
|
aal5VccCurrentLengthError
|
|
Gauge32,
|
|
aal5VccCurrentInputCongestionDropped
|
|
Gauge32,
|
|
aal5VccCurrentOutputCongestionDropped
|
|
Gauge32
|
|
}
|
|
|
|
aal5VccCurrentInFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames,
|
|
encountered by the AAL5 interface in the current 15 minute
|
|
interval."
|
|
::= { aal5VccCurrentEntry 1 }
|
|
|
|
aal5VccCurrentOutFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted frames,
|
|
encountered by the AAL5 interface in the current 15 minute
|
|
interval."
|
|
::= { aal5VccCurrentEntry 2 }
|
|
|
|
aal5VccCurrentUnknownProtocolFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of frames that were
|
|
discarded due to unsupported protocol encapsulation,
|
|
encountered by the AAL5 interface in the current 15 minute
|
|
interval."
|
|
::= { aal5VccCurrentEntry 3 }
|
|
|
|
aal5VccCurrentCrcErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of AAL5 CPCS PDUs
|
|
received with CRC-32 errors, encountered by the AAL5
|
|
interface in the current 15 minute interval."
|
|
::= { aal5VccCurrentEntry 4 }
|
|
|
|
aal5VccCurrentLengthError OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames
|
|
with length error, encountered by the AAL5 interface in the
|
|
current 15 minute interval."
|
|
::= { aal5VccCurrentEntry 5 }
|
|
|
|
aal5VccCurrentInputCongestionDropped OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
dropped frames due to congestion, encountered by
|
|
the AAL5 interface on the Receive direction
|
|
in the current 15 minute interval."
|
|
::= { aal5VccCurrentEntry 6 }
|
|
|
|
aal5VccCurrentOutputCongestionDropped OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of
|
|
dropped frames due to congestion, encountered by
|
|
the AAL5 interface on the Transmit direction
|
|
in the current 15 minute interval."
|
|
::= { aal5VccCurrentEntry 7 }
|
|
|
|
|
|
-- Interval Table
|
|
|
|
aal5VccIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Aal5VccIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The AAL5 Interval table."
|
|
::= { atmIfPerformance 6 }
|
|
|
|
aal5VccIntervalEntry OBJECT-TYPE
|
|
SYNTAX Aal5VccIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the AAL5 Interval table."
|
|
INDEX { ifIndex, aal5VccVpi, aal5VccVci, aal5VccIntervalNumber }
|
|
::= { aal5VccIntervalTable 1 }
|
|
|
|
Aal5VccIntervalEntry
|
|
::= SEQUENCE {
|
|
aal5VccIntervalNumber
|
|
Integer32,
|
|
aal5VccIntervalInFrames
|
|
Gauge32,
|
|
aal5VccIntervalOutFrames
|
|
Gauge32,
|
|
aal5VccIntervalUnknownProtocolFrames
|
|
Gauge32,
|
|
aal5VccIntervalCrcErrors
|
|
Gauge32,
|
|
aal5VccIntervalLengthError
|
|
Gauge32,
|
|
aal5VccIntervalInputCongestionDropped
|
|
Gauge32,
|
|
aal5VccIntervalOutputCongestionDropped
|
|
Gauge32
|
|
}
|
|
|
|
aal5VccIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals exist)."
|
|
::= { aal5VccIntervalEntry 1 }
|
|
|
|
|
|
aal5VccIntervalInFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames,
|
|
encountered by the AAL5 interface in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { aal5VccIntervalEntry 2 }
|
|
|
|
aal5VccIntervalOutFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted frames,
|
|
encountered by the AAL5 interface in in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { aal5VccIntervalEntry 3 }
|
|
|
|
aal5VccIntervalUnknownProtocolFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of frames that were
|
|
discarded due to unsupported protocol encapsulation,
|
|
encountered by the AAL5 interface in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { aal5VccIntervalEntry 4 }
|
|
|
|
aal5VccIntervalCrcErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of AAL5 CPCS PDUs
|
|
received with CRC-32 errors, encountered by the AAL5
|
|
interface in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { aal5VccIntervalEntry 5 }
|
|
|
|
aal5VccIntervalLengthError OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames
|
|
with length error, encountered by the AAL5 interface in one
|
|
of the previous 96, individual 15 minute, intervals."
|
|
::= { aal5VccIntervalEntry 6 }
|
|
|
|
aal5VccIntervalInputCongestionDropped OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of dropped frames
|
|
due to a congestion, encountered by the AAL5 interface on
|
|
the Receive direction in one of the previous 96, individual
|
|
15 minute, intervals"
|
|
::= { aal5VccIntervalEntry 7 }
|
|
|
|
aal5VccIntervalOutputCongestionDropped OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of dropped frames
|
|
due to a congestion, encountered by the AAL5 interface on
|
|
the Transmit direction in one of the previous 96, individual
|
|
15 minute, intervals"
|
|
::= { aal5VccIntervalEntry 8 }
|
|
|
|
|
|
-- END
|
|
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\ethif.txt
|
|
--
|
|
--01/08/2000
|
|
--By: Smadar Tauber
|
|
--s:\doc\rdv\mib\ver485\ethIf.txt
|
|
--File: ethIf.txt
|
|
|
|
|
|
--EthIf MIB - separated from mpmx.txt
|
|
|
|
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}
|
|
|
|
--Last update: 27-Jan-2003 by Shay Hararim
|
|
|
|
|
|
--
|
|
-- diverseIf - diverse NON-WAN interfaces of WAN products
|
|
--
|
|
|
|
--Ethernet Interface
|
|
|
|
|
|
ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} --Ethernet Interface
|
|
|
|
ethIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EthIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { ethIf 1}
|
|
|
|
ethIfEntry OBJECT-TYPE
|
|
SYNTAX EthIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {ethIfIdx}
|
|
::= {ethIfTable 1}
|
|
|
|
EthIfEntry ::=
|
|
SEQUENCE {
|
|
ethIfIdx Integer32,
|
|
ethMode INTEGER,
|
|
ethBridgingMode INTEGER,
|
|
ethEncapsulationCRCMode INTEGER,
|
|
ethBackPressure INTEGER,
|
|
ethLimit4 INTEGER,
|
|
ethSkipInitReset INTEGER,
|
|
ethMulticastBlock INTEGER,
|
|
ethBroadcastBlock INTEGER,
|
|
ethSpeed INTEGER,
|
|
ethRip2 INTEGER,
|
|
ethPortPriority INTEGER,
|
|
ethPortMngEnable INTEGER,
|
|
ethFlowCtrlMacAddress MacAddress
|
|
|
|
}
|
|
|
|
ethIfIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index of the ethernet interface/port."
|
|
::= {ethIfEntry 1}
|
|
|
|
ethMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
halfDuplex (1),
|
|
fullDuplex (2),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Ethernet mode of operation."
|
|
::= {ethIfEntry 2}
|
|
|
|
ethBridgingMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
filtered (1),
|
|
transparent (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the bridging mode of the Ethernet
|
|
interface. "
|
|
::= {ethIfEntry 3}
|
|
|
|
ethEncapsulationCRCMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
withCRC (2),
|
|
withoutCRC (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object define the encapsulation type requested for the
|
|
Ethernet interface. It indicates if we transfer the Ethernet
|
|
frame to the other side with or without the CRC. "
|
|
::= {ethIfEntry 4}
|
|
|
|
ethBackPressure OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines whether to enable or disable Back pressure.
|
|
Back Pressure is a flow control parameter. "
|
|
::= {ethIfEntry 5}
|
|
|
|
ethLimit4 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determine the Back off algorithm mode.
|
|
Every 4 following collisions the Framer will be thrown out
|
|
(4 times more than usuall)."
|
|
::= {ethIfEntry 6}
|
|
|
|
ethSkipInitReset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
notSkip (2),
|
|
skip (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines whether read status on reset. "
|
|
::= {ethIfEntry 7}
|
|
|
|
ethMulticastBlock OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
unBlock (2),
|
|
block (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines whether to send multicast message to WAN from LAN or not. "
|
|
::= {ethIfEntry 8}
|
|
|
|
ethBroadcastBlock OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
unBlock (2),
|
|
block (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines whether to send broadcast message to WAN from LAN or not."
|
|
::= {ethIfEntry 9}
|
|
|
|
ethSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
s10Mbps (2),
|
|
s100Mbps (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines the line speed."
|
|
::= {ethIfEntry 10}
|
|
|
|
|
|
ethRip2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines whether to send RIP II message
|
|
to WAN from LAN or not"
|
|
::= {ethIfEntry 11}
|
|
|
|
ethPortPriority OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
fixed (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines if priority is to
|
|
be considered for this Port."
|
|
::= {ethIfEntry 12}
|
|
|
|
ethPortMngEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines whether management data can pass through this Port."
|
|
::= {ethIfEntry 13}
|
|
|
|
ethFlowCtrlMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case of flow control - transmit frame with this specific MAC address
|
|
to inform the other end to stop sending frames.
|
|
Default: 01.80.C2.00.00.01."
|
|
::= {ethIfEntry 14}
|
|
|
|
|
|
|
|
|
|
ethIfPerformance OBJECT IDENTIFIER ::= {ethIf 2}
|
|
|
|
ethIfCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EthIfCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Ethernet Current table."
|
|
::= { ethIfPerformance 1}
|
|
|
|
ethIfCurrentEntry OBJECT-TYPE
|
|
SYNTAX EthIfCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Ethernet Current table."
|
|
INDEX {ethIfCurrentIndex}
|
|
::= {ethIfCurrentTable 1}
|
|
|
|
EthIfCurrentEntry ::=
|
|
SEQUENCE {
|
|
ethIfCurrentIndex
|
|
Integer32,
|
|
ethIfCurrentStatus
|
|
OCTET STRING,
|
|
ethIfCurrentInFrames
|
|
Gauge32,
|
|
ethIfCurrentInOctets
|
|
Gauge32,
|
|
ethIfCurrentAlignmentErrors
|
|
Gauge32,
|
|
ethIfCurrentFCSErrors
|
|
Gauge32,
|
|
ethIfCurrentLengthError
|
|
Gauge32,
|
|
ethIfCurrentOutFrames
|
|
Gauge32,
|
|
ethIfCurrentOutOctets
|
|
Gauge32,
|
|
ethIfCurrentSingleCollisionFrames
|
|
Gauge32,
|
|
ethIfCurrentMultipleCollisionFrames
|
|
Gauge32,
|
|
ethIfCurrentDeferredTransmissions
|
|
Gauge32,
|
|
ethIfCurrentLateCollisions
|
|
Gauge32,
|
|
ethIfCurrentCarrierSenseErrors
|
|
Gauge32,
|
|
ethIfCurrentInputCongestionDropped
|
|
Gauge32,
|
|
ethIfCurrentOutputCongestionDropped
|
|
Gauge32
|
|
}
|
|
|
|
ethIfCurrentIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the Ethernet interface.
|
|
It may be ifIndex."
|
|
::= { ethIfCurrentEntry 1 }
|
|
|
|
ethIfCurrentStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - Valid.
|
|
1 - redundantLinkSwitch - the link has been switched
|
|
by a redundancy mechanism.
|
|
2 - discontinuity - module was partialy out.
|
|
4 - notValid - module is out."
|
|
::= { ethIfCurrentEntry 2 }
|
|
|
|
ethIfCurrentInFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames,
|
|
encountered by the Ethernet interface in the current 15 minute
|
|
interval."
|
|
::= { ethIfCurrentEntry 3 }
|
|
|
|
ethIfCurrentInOctets OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received octets,
|
|
encountered by the Ethernet interface in the current 15 minute
|
|
interval."
|
|
::= { ethIfCurrentEntry 4 }
|
|
|
|
ethIfCurrentAlignmentErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames,
|
|
which are not complete (The result of dividing the number
|
|
of bits by 8 is not an Integer), encountered by the Ethernet
|
|
interface in the current 15 minute interval."
|
|
::= { ethIfCurrentEntry 5 }
|
|
|
|
ethIfCurrentFCSErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames
|
|
that didn't pass the FCS test, encountered by the Ethernet
|
|
interface in the current 15 minute interval."
|
|
::= { ethIfCurrentEntry 6 }
|
|
|
|
ethIfCurrentLengthError OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames
|
|
with length error, encountered by the Ethernet interface in
|
|
the current 15 minute interval."
|
|
::= { ethIfCurrentEntry 7 }
|
|
|
|
ethIfCurrentOutFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted frames,
|
|
encountered by the Ethernet interface in the current 15 minute
|
|
interval."
|
|
::= { ethIfCurrentEntry 8 }
|
|
|
|
ethIfCurrentOutOctets OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted octets,
|
|
encountered by the Ethernet interface in the current 15 minute
|
|
interval."
|
|
::= { ethIfCurrentEntry 9 }
|
|
|
|
ethIfCurrentSingleCollisionFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of successfully
|
|
transmitted frames for which transmission was inhibited by
|
|
exactly one collision, encountered by the Ethernet interface
|
|
in the current 15 minute interval."
|
|
::= { ethIfCurrentEntry 10 }
|
|
|
|
ethIfCurrentMultipleCollisionFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of successfully
|
|
transmitted frames for which transmission was inhibited by
|
|
more than one collision, encountered by the Ethernet interface
|
|
in the current 15 minute interval."
|
|
::= { ethIfCurrentEntry 11 }
|
|
|
|
ethIfCurrentDeferredTransmissions OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted frames
|
|
for which the first transmission attempt was delayed due to a
|
|
busy media, encountered by the Ethernet interface in the
|
|
current 15 minute interval."
|
|
::= { ethIfCurrentEntry 12 }
|
|
|
|
ethIfCurrentLateCollisions OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of times that a
|
|
collision was detected later than the first 64 bytes of the
|
|
frame, encountered by the Ethernet interface in the current
|
|
15 minute interval."
|
|
::= { ethIfCurrentEntry 13 }
|
|
|
|
ethIfCurrentCarrierSenseErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of times that the
|
|
carrier sense condition was lost or never asserted when
|
|
attempting to transmit a frame, encountered by the Ethernet
|
|
interface in the current 15 minute interval."
|
|
::= { ethIfCurrentEntry 14 }
|
|
|
|
ethIfCurrentInputCongestionDropped OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of frames dropped
|
|
due to lack of buffers in ingress pool, encountered by
|
|
the Ethernet interface in the current 15 minute interval."
|
|
::= { ethIfCurrentEntry 15 }
|
|
|
|
ethIfCurrentOutputCongestionDropped OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of dropped frames
|
|
due to a congestion, encountered by the Transmit direction
|
|
to the Ethernet interface in the current 15 minute interval."
|
|
::= { ethIfCurrentEntry 16 }
|
|
|
|
|
|
--Interval Table
|
|
|
|
ethIfIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EthIfIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Ethernet Interval table."
|
|
::= { ethIfPerformance 2 }
|
|
|
|
ethIfIntervalEntry OBJECT-TYPE
|
|
SYNTAX EthIfIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Ethernet Interval table."
|
|
INDEX { ethIfIntervalIndex, ethIfIntervalNumber }
|
|
::= {ethIfIntervalTable 1}
|
|
|
|
EthIfIntervalEntry ::=
|
|
SEQUENCE {
|
|
ethIfIntervalIndex
|
|
Integer32,
|
|
ethIfIntervalNumber
|
|
Integer32,
|
|
ethIfIntervalStatus
|
|
OCTET STRING,
|
|
ethIfIntervalInFrames
|
|
Gauge32,
|
|
ethIfIntervalInOctets
|
|
Gauge32,
|
|
ethIfIntervalAlignmentErrors
|
|
Gauge32,
|
|
ethIfIntervalFCSErrors
|
|
Gauge32,
|
|
ethIfIntervalLengthError
|
|
Gauge32,
|
|
ethIfIntervalOutFrames
|
|
Gauge32,
|
|
ethIfIntervalOutOctets
|
|
Gauge32,
|
|
ethIfIntervalSingleCollisionFrames
|
|
Gauge32,
|
|
ethIfIntervalMultipleCollisionFrames
|
|
Gauge32,
|
|
ethIfIntervalDeferredTransmissions
|
|
Gauge32,
|
|
ethIfIntervalLateCollisions
|
|
Gauge32,
|
|
ethIfIntervalCarrierSenseErrors
|
|
Gauge32,
|
|
ethIfIntervalInputCongestionDropped
|
|
Gauge32,
|
|
ethIfIntervalOutputCongestionDropped
|
|
Gauge32
|
|
}
|
|
|
|
ethIfIntervalIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the Ethernet interface.
|
|
It may be ifIndex."
|
|
::= { ethIfIntervalEntry 1 }
|
|
|
|
ethIfIntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals exist)."
|
|
::= { ethIfIntervalEntry 2 }
|
|
|
|
ethIfIntervalStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The statuses of the current interval:
|
|
0 - Valid.
|
|
1 - redundantLinkSwitch - the link has been switched
|
|
by a redundancy mechanism.
|
|
2 - discontinuity - module was partialy out.
|
|
4 - notValid - module is out."
|
|
::= { ethIfIntervalEntry 3 }
|
|
|
|
ethIfIntervalInFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames,
|
|
encountered by the Ethernet interface in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { ethIfIntervalEntry 4 }
|
|
|
|
ethIfIntervalInOctets OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received octets,
|
|
encountered by the Ethernet interface in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { ethIfIntervalEntry 5 }
|
|
|
|
ethIfIntervalAlignmentErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames,
|
|
which are not complete (The result of dividing the number
|
|
of bits by 8 is not an Integer), encountered by the Ethernet
|
|
interface in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { ethIfIntervalEntry 6 }
|
|
|
|
ethIfIntervalFCSErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames
|
|
that didn't pass the FCS test, encountered by the Ethernet
|
|
interface in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { ethIfIntervalEntry 7 }
|
|
|
|
ethIfIntervalLengthError OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received frames
|
|
with length error, encountered by the Ethernet interface in
|
|
one of the previous 96, individual 15 minute, intervals."
|
|
::= { ethIfIntervalEntry 8 }
|
|
|
|
ethIfIntervalOutFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted frames,
|
|
encountered by the Ethernet interface in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { ethIfIntervalEntry 9 }
|
|
|
|
ethIfIntervalOutOctets OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted octets,
|
|
encountered by the Ethernet interface in one of the previous
|
|
96, individual 15 minute, intervals."
|
|
::= { ethIfIntervalEntry 10 }
|
|
|
|
ethIfIntervalSingleCollisionFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of successfully
|
|
transmitted frames for which transmission was inhibited by
|
|
exactly one collision, encountered by the Ethernet
|
|
interface in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { ethIfIntervalEntry 11 }
|
|
|
|
ethIfIntervalMultipleCollisionFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of successfully
|
|
transmitted frames for which transmission was inhibited by
|
|
more than one collision, encountered by the Ethernet
|
|
interface in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { ethIfIntervalEntry 12 }
|
|
|
|
ethIfIntervalDeferredTransmissions OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted frames
|
|
for which the first transmission attempt was delayed due to a
|
|
busy media, encountered by the Ethernet interface in one of
|
|
the previous 96, individual 15 minute, intervals."
|
|
::= { ethIfIntervalEntry 13 }
|
|
|
|
ethIfIntervalLateCollisions OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of times that a
|
|
collision was detected later than the first 64 bytes of the
|
|
frame, encountered by the Ethernet interface in one of the
|
|
previous 96, individual 15 minute, intervals."
|
|
::= { ethIfIntervalEntry 14 }
|
|
|
|
ethIfIntervalCarrierSenseErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of times that the
|
|
carrier sense condition was lost or never asserted when
|
|
attempting to transmit a frame, encountered by the Ethernet
|
|
interface in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { ethIfIntervalEntry 15 }
|
|
|
|
ethIfIntervalInputCongestionDropped OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of dropped frames
|
|
due to a congestion, encountered by the Receive direction
|
|
to the Ethernet interface in one of the previous 96, individual
|
|
15 minute, intervals."
|
|
::= { ethIfIntervalEntry 16 }
|
|
|
|
ethIfIntervalOutputCongestionDropped OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of dropped frames
|
|
due to a congestion, encountered by the Transmit direction
|
|
to the Ethernet interface in one of the previous 96, individual
|
|
15 minute, intervals."
|
|
::= { ethIfIntervalEntry 17 }
|
|
|
|
|
|
ethPerformanceMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
countOK (2),
|
|
countFail (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether OK or Fail statistics will be counted."
|
|
::= {ethIfPerformance 3}
|
|
|
|
|
|
ethIfPerfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EthIfPerfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Ethernet Performance table."
|
|
::= { ethIfPerformance 4}
|
|
|
|
ethIfPerfEntry OBJECT-TYPE
|
|
SYNTAX EthIfPerfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Ethernet Performance table."
|
|
INDEX {ethIfIdx}
|
|
::= {ethIfPerfTable 1}
|
|
|
|
EthIfPerfEntry ::=
|
|
SEQUENCE {
|
|
ethIfPerfInOkFrames
|
|
Gauge32,
|
|
ethIfPerfOutOkFrames
|
|
Gauge32,
|
|
ethIfPerfTotalCollisions
|
|
Gauge32
|
|
}
|
|
|
|
|
|
ethIfPerfInOkFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of received OK frames,
|
|
encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2)
|
|
or Reset Statistics was done."
|
|
::= { ethIfPerfEntry 1 }
|
|
|
|
|
|
ethIfPerfOutOkFrames OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of transmitted OK frames,
|
|
encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2)
|
|
or Reset Statistics was done."
|
|
::= { ethIfPerfEntry 2 }
|
|
|
|
|
|
ethIfPerfTotalCollisions OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the total number of collisions
|
|
of any type encountered by the Ethernet interface since
|
|
ethPerformanceMode Set to countOK (2) or Reset Statistics was done"
|
|
::= { ethIfPerfEntry 3 }
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver485\atm\atmCes.txt
|
|
--
|
|
--
|
|
-- File: v:\doc\rdv\mib\ver485\atm\atmCes.txt
|
|
-- Date: 17/01/02
|
|
-- By: Ilana Schvetz
|
|
|
|
-- Last Update: 17-Jan-02 By Ilana Schvetz
|
|
--
|
|
-- AAL1 statistics. An addition to ATMF-CES (ces.mib)
|
|
--
|
|
|
|
atmCes OBJECT IDENTIFIER ::= {radAtm 9}
|
|
|
|
atmCesPerformance OBJECT IDENTIFIER ::= {atmCes 1 }
|
|
|
|
atmCesAal1CurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmCesAal1CurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The AAL1 Current table."
|
|
::= { atmCesPerformance 1 }
|
|
|
|
atmCesAal1CurrentEntry OBJECT-TYPE
|
|
SYNTAX AtmCesAal1CurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the AAL1 Current table."
|
|
INDEX { atmCesAal1CurrentIfIndex }
|
|
::= { atmCesAal1CurrentTable 1 }
|
|
|
|
AtmCesAal1CurrentEntry ::=
|
|
SEQUENCE {
|
|
atmCesAal1CurrentIfIndex
|
|
Integer32,
|
|
atmCesAal1CurrentSeqErrors
|
|
Gauge32,
|
|
atmCesAal1CurrentHdrErrors
|
|
Gauge32,
|
|
atmCesAal1CurrentPointerReframes
|
|
Gauge32,
|
|
atmCesAal1CurrentBufUnderflows
|
|
Gauge32,
|
|
atmCesAal1CurrentBufOverflows
|
|
Gauge32
|
|
}
|
|
|
|
atmCesAal1CurrentIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the AAL1 interface.
|
|
It may be ifIndex."
|
|
::= { atmCesAal1CurrentEntry 1 }
|
|
|
|
atmCesAal1CurrentSeqErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Discarded
|
|
cells due to wrong sequence number, encountered
|
|
by an AAL1 interface in the current 15 minute interval."
|
|
::= { atmCesAal1CurrentEntry 2 }
|
|
|
|
atmCesAal1CurrentHdrErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Discarded
|
|
cells due to bad AAL1 header error (including correctable
|
|
and uncorrectable CRC, and bad parity), encountered
|
|
by an AAL1 interface in the current 15 minute interval."
|
|
::= { atmCesAal1CurrentEntry 3 }
|
|
|
|
atmCesAal1CurrentPointerReframes OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of events in
|
|
which a SDT pointer isn't where it is expected to be,
|
|
and must be reacquired, encountered by an AAL1 interface
|
|
in the current 15 minute interval."
|
|
::= { atmCesAal1CurrentEntry 4 }
|
|
|
|
atmCesAal1CurrentBufUnderflows OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of buffer
|
|
underflow events, encountered by an AAL1 interface
|
|
in the current 15 minute interval."
|
|
::= { atmCesAal1CurrentEntry 5 }
|
|
|
|
atmCesAal1CurrentBufOverflows OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of buffer
|
|
overflow events, encountered by an AAL1 interface
|
|
in the current 15 minute interval."
|
|
::= { atmCesAal1CurrentEntry 6 }
|
|
|
|
|
|
--Interval Table
|
|
|
|
|
|
atmCesAal1IntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmCesAal1IntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The AAL1 Interval table."
|
|
::= { atmCesPerformance 2 }
|
|
|
|
atmCesAal1IntervalEntry OBJECT-TYPE
|
|
SYNTAX AtmCesAal1IntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the AAL1 Interval table."
|
|
INDEX { atmCesAal1IntervalIfIndex, atmCesAal1IntervalNumber }
|
|
::= { atmCesAal1IntervalTable 1 }
|
|
|
|
AtmCesAal1IntervalEntry ::=
|
|
SEQUENCE {
|
|
atmCesAal1IntervalIfIndex
|
|
Integer32,
|
|
atmCesAal1IntervalNumber
|
|
Integer32,
|
|
atmCesAal1IntervalSeqErrors
|
|
Gauge32,
|
|
atmCesAal1IntervalHdrErrors
|
|
Gauge32,
|
|
atmCesAal1IntervalPointerReframes
|
|
Gauge32,
|
|
atmCesAal1IntervalBufUnderflows
|
|
Gauge32,
|
|
atmCesAal1IntervalBufOverflows
|
|
Gauge32
|
|
}
|
|
|
|
|
|
atmCesAal1IntervalIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the AAL1 interface.
|
|
It may be ifIndex."
|
|
::= { atmCesAal1IntervalEntry 1 }
|
|
|
|
atmCesAal1IntervalNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A number between 1 and 96, where 1 is the most
|
|
recently completed 15 minute interval and 96 is
|
|
the least recently completed 15 minutes interval
|
|
(assuming that all 96 intervals exist)."
|
|
::= { atmCesAal1IntervalEntry 2 }
|
|
|
|
atmCesAal1IntervalSeqErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Discarded
|
|
cells due to wrong sequence number, encountered
|
|
by an AAL1 interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { atmCesAal1IntervalEntry 3 }
|
|
|
|
atmCesAal1IntervalHdrErrors OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of Discarded
|
|
cells due to bad AAL1 header error (including correctable
|
|
and uncorrectable CRC, plus bad parity), encountered
|
|
by an AAL1 interface in one of the previous 96,
|
|
individual 15 minute, intervals."
|
|
::= { atmCesAal1IntervalEntry 4 }
|
|
|
|
atmCesAal1IntervalPointerReframes OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of events in
|
|
which a SDT pointer isn't where it is expected to be,
|
|
and must be reacquired, encountered by an AAL1 interface
|
|
in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { atmCesAal1IntervalEntry 5 }
|
|
|
|
atmCesAal1IntervalBufUnderflows OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of buffer
|
|
underflow events, encountered by an AAL1 interface
|
|
in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { atmCesAal1IntervalEntry 6 }
|
|
|
|
atmCesAal1IntervalBufOverflows OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter associated with the number of buffer
|
|
overflow events, encountered by an AAL1 interface
|
|
in one of the previous 96, individual 15 minute,
|
|
intervals."
|
|
::= { atmCesAal1IntervalEntry 7 }
|
|
|
|
|
|
-- Extension for CES Configuration Table
|
|
|
|
atmCesConfiguration OBJECT IDENTIFIER ::= {atmCes 2 }
|
|
|
|
|
|
atmCesXConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmCesXConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is an extension of atmfCESConfTable table."
|
|
::= { atmCesConfiguration 1 }
|
|
|
|
atmCesXConfEntry OBJECT-TYPE
|
|
SYNTAX AtmCesXConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conceptual row in atmfCESConfTable.
|
|
A new row is created in this table upon each new CES VCC creation."
|
|
AUGMENTS { atmfCESConfEntry }
|
|
::= { atmCesXConfTable 1 }
|
|
|
|
AtmCesXConfEntry ::= SEQUENCE {
|
|
atmCesXConfCBRMode INTEGER
|
|
}
|
|
|
|
atmCesXConfCBRMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (2),
|
|
spaced (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines if to use Spaced or Normal CBR.
|
|
|
|
Normal - TD will be allocated from the policing range (described
|
|
in ACE2002 NMS SRS). The PCR is expanded with a constant
|
|
value of 30 cell/sec.
|
|
Spaced - TD will be allocated from the spacing range (described
|
|
in ACE2002 NMS SRS). The PCR and CDVT will be expanded
|
|
as described for Normal, and the CES traffic including
|
|
the OAM will be spaced out at the TD's PCR.
|
|
This mode is used to prevent CDVT violation due to OAM
|
|
cell insertion with the CES traffic."
|
|
::= { atmCesXConfEntry 1 }
|
|
--
|
|
-- file :v:\doc\rdv\mib\ver495\atm\atmRou~1.txt
|
|
--
|
|
--Version: 4.95
|
|
--
|
|
--First Version Date: 12-Aug-2002
|
|
--By: Shay Harari
|
|
--File: atmRouter.txt
|
|
--
|
|
--Last update: 20-Oct-2002
|
|
--By: Ilana Schvetz
|
|
|
|
|
|
radAtmRouter OBJECT IDENTIFIER ::= { radAtm 10 }
|
|
|
|
|
|
-- Extension of the ATM Logical IP Subnet Interface Mapping Table
|
|
-- ( ipoaLisIfMappingTable from RFC 2320 )
|
|
|
|
atmIpoaLisIfMappingXTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtmIpoaLisIfMappingXEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is an extension of a table
|
|
from RFC 2320: ipoaLisIfMappingTable -
|
|
The ATM Logical IP Subnet Interface Mapping Table."
|
|
::= { radAtmRouter 1 }
|
|
|
|
atmIpoaLisIfMappingXEntry OBJECT-TYPE
|
|
SYNTAX AtmIpoaLisIfMappingXEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conceptual row in ipoaLisIfMappingTable."
|
|
AUGMENTS { ipoaLisIfMappingEntry }
|
|
::= { atmIpoaLisIfMappingXTable 1 }
|
|
|
|
AtmIpoaLisIfMappingXEntry ::= SEQUENCE {
|
|
atmIpoaLisIfMappingType
|
|
INTEGER,
|
|
atmIpoaLisIfMappingIPAddress
|
|
IpAddress
|
|
}
|
|
|
|
atmIpoaLisIfMappingType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
static(2),
|
|
inAtmArp(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Mapping Type."
|
|
::= { atmIpoaLisIfMappingXEntry 1 }
|
|
|
|
atmIpoaLisIfMappingIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is applicable for
|
|
atmIpoaLisIfMappingTypeIP=static(2).
|
|
This parameter is the IP Address assigned
|
|
by the user when applicable."
|
|
::= { atmIpoaLisIfMappingXEntry 2 }
|
|
|
|
|
|
radAtmRtrInAtmArpInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time interval (in seconds) between sending of
|
|
two InATMARP requests."
|
|
::= { radAtmRouter 2 }
|
|
|
|
radAtmRtrInAtmArpAgingTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in seconds) that passes until an
|
|
entry is deleted, unless this entry
|
|
was previously updated by a new inATMARP
|
|
request or response.
|
|
|
|
This variable value should be greater than
|
|
the value of radAtmRtrInAtmArpInterval,
|
|
so that the entry won't be deleted before
|
|
an InATMARP request was sent."
|
|
::= { radAtmRouter 3 }
|
|
|
|
|
|
|
|
-- clksrc.txt is the clock source table that was taken from dacs.txt for ace2002 use
|
|
|
|
END
|
|
|