-- QTECH-NTP-MIB.mib: Qtech NTP MIB file
|
|
--
|
|
-- May 2009, linshuangfeng
|
|
--
|
|
-- Copyright (c) 2009 by Qtech Networks Co.,Ltd.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
--
|
|
|
|
QTECH-NTP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
IpAddress,
|
|
Integer32
|
|
FROM SNMPv2-SMI
|
|
RowStatus
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
InetAddressType,
|
|
InetAddress
|
|
FROM INET-ADDRESS-MIB
|
|
qtechMgmt
|
|
FROM QTECH-SMI;
|
|
|
|
qtechNtpMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200905140000Z"
|
|
ORGANIZATION "Qtech Networks Co.,Ltd."
|
|
CONTACT-INFO
|
|
"
|
|
Tel: 4008-111-000
|
|
|
|
E-mail: service@qtech.com.cn"
|
|
DESCRIPTION
|
|
"This module defines qtech ntp mibs."
|
|
REVISION "200905140000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { qtechMgmt 49}
|
|
|
|
qtechNtpMIBObjects OBJECT IDENTIFIER ::= { qtechNtpMIB 1 }
|
|
qtechNtpMIBConformance OBJECT IDENTIFIER ::= { qtechNtpMIB 2 }
|
|
qtechntpSystem OBJECT IDENTIFIER ::= { qtechNtpMIBObjects 1 }
|
|
qtechNtpMIBCompliances OBJECT IDENTIFIER ::= { qtechNtpMIBConformance 1 }
|
|
qtechNtpMIBGroups OBJECT IDENTIFIER ::= { qtechNtpMIBConformance 2 }
|
|
|
|
NTPTimeStamp ::= OCTET STRING(SIZE(8))
|
|
-- TEXTUAL-CONVENTION
|
|
-- Status
|
|
-- mandatory
|
|
-- Descr
|
|
-- NTP timestamps are represented as a 64-bit
|
|
-- unsigned fixed-point number, in seconds relative to
|
|
-- 00:00 on 1 January 1900. The integer part is in the
|
|
-- first 32 bits and the fraction part is in the last
|
|
-- 32 bits.
|
|
-- Refer
|
|
-- D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
-- RFC-1305, March 1992, Section 3.1
|
|
|
|
NTPLeapIndicator ::= INTEGER {
|
|
-- enum value of zero may cause problems
|
|
noWarning(0),
|
|
addSecond(1),
|
|
subtractSecond(2),
|
|
alarm(3)
|
|
}
|
|
-- TEXTUAL-CONVENTION
|
|
-- Status
|
|
-- mandatory
|
|
-- Descr
|
|
-- This is a two-bit code warning of an impending leap
|
|
-- second to be inserted in the NTP timescale. The bits
|
|
-- are set before 23:59 on the day of insertion and reset
|
|
-- after 00:00 on the following day. This causes the
|
|
-- number of seconds (rollover interval) in the day of
|
|
-- insertion to be increased or decreased by one. The two
|
|
-- bits are coded as below,
|
|
-- 00, no warning
|
|
-- 01, last minute has 61 seconds
|
|
-- 10, last minute has 59 seconds
|
|
-- 11, alarm condition (clock not synchronized)
|
|
-- Refer
|
|
-- D.L. Mills, 'Network Time Protocol(Version 3)',
|
|
-- RFC-1305, March 1992, Section 3.2.1
|
|
|
|
NTPSignedTimeValue ::= OCTET STRING(SIZE(4))
|
|
-- TEXTUAL-CONVENTION
|
|
-- Status
|
|
-- mandatory
|
|
-- Descr
|
|
-- The time in seconds that could represent signed
|
|
-- quantities like time delay with respect to some
|
|
-- source. This textual-convention is specific to
|
|
-- implementation of NTP where 32-bit integers are used
|
|
-- for such quantities. The signed integer part is in
|
|
-- the first 16 bits and the fraction part is in the
|
|
-- last 16 bits.
|
|
-- Refer
|
|
-- D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
-- RFC-1305, March 1992, Sections 2, 3.2.1
|
|
|
|
NTPUnsignedTimeValue ::= OCTET STRING(SIZE(4))
|
|
-- TEXTUAL-CONVENTION
|
|
-- Status
|
|
-- mandatory
|
|
-- Descr
|
|
-- The time in seconds that could represent unsigned
|
|
-- quantities like maximum error of the local clock
|
|
-- with respect to some source. This textual-convention
|
|
-- is specific to implementation of NTP where
|
|
-- 32-bit integers are used for such quantities. The
|
|
-- unsigned integer part is in the first 16 bits and the
|
|
-- fraction part is in the last 16 bits.
|
|
-- Refer
|
|
-- D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
-- RFC-1305, March 1992, Sections 2, 3.2.1
|
|
|
|
NTPStratum ::= INTEGER(0..255)
|
|
-- TEXTUAL-CONVENTION
|
|
-- Status
|
|
-- mandatory
|
|
-- Descr
|
|
-- Indicates the stratum of the clock. The stratum
|
|
-- defines the accuracy of a time server. Higher the
|
|
-- stratum, lower the accuracy.
|
|
-- 0, unspecified
|
|
-- 1, primary reference (e.g., calibrated atomic clock,
|
|
-- radio clock)
|
|
-- 2-255, secondary reference (via NTP)
|
|
-- Refer
|
|
-- D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
-- RFC-1305, March 1992, Section 2.2
|
|
|
|
NTPRefId ::= OCTET STRING(SIZE(4))
|
|
-- TEXTUAL-CONVENTION
|
|
-- Status
|
|
-- mandatory
|
|
-- Descr
|
|
-- The reference clock identifier. In the case of
|
|
-- stratum 0 (unspecified) or stratum 1 (primary
|
|
-- reference source), this is a four-octet,
|
|
-- left-justified, zero-padded ASCII string as defined
|
|
-- in RFC-1305. In the case of stratum 2 and greater
|
|
-- (secondary reference) this is the four-octet Internet
|
|
-- address of the peer selected for synchronization.
|
|
--
|
|
-- Some examples of stratum 0 identifiers are,
|
|
-- DCN, DCN routing protocol
|
|
-- NIST, NIST public modem
|
|
-- TSP, TSP time protocol
|
|
-- DTS, Digital Time Service
|
|
--
|
|
-- Some examples of stratum 1 identifiers are,
|
|
-- ATOM, Atomic clock (calibrated)
|
|
-- VLF, VLF radio (OMEGA,, etc.)
|
|
-- LORC, LORAN-C radionavigation
|
|
-- GOES, GOES UHF environment satellite
|
|
-- GPS, GPS UHF satellite positioning
|
|
-- Refer
|
|
-- D.L. Mills, Network Time Protocol (Version 3)',
|
|
-- RFC-1305, March 1992, Section 3.2.1
|
|
|
|
qtechntpSysLeap OBJECT-TYPE
|
|
SYNTAX NTPLeapIndicator
|
|
-- Rsyntax INTEGER {
|
|
-- enum value of zero may cause problems
|
|
-- noWarning(0),
|
|
-- addSecond(1),
|
|
-- subtractSecond(2),
|
|
-- alarm(3)
|
|
-- }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Two-bit code warning of an impending leap second to
|
|
be inserted in the NTP timescale. This object can be
|
|
set only when the qtechntpSysStratum has a value of 1."
|
|
::= { qtechntpSystem 1 }
|
|
|
|
qtechntpSysStratum OBJECT-TYPE
|
|
SYNTAX NTPStratum
|
|
-- Rsyntax INTEGER(0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The stratum of the local clock. If the value is set
|
|
to 1, i.e., this is a primary reference, then the
|
|
Primary-Clock procedure described in Section 3.4.6,
|
|
in RFC-1305 is invoked."
|
|
::= { qtechntpSystem 2 }
|
|
|
|
qtechntpSysPrecision OBJECT-TYPE
|
|
SYNTAX INTEGER(-24..24)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signed integer indicating the precision
|
|
of the system clock, in seconds to the nearest
|
|
power of two. The value must be rounded to the
|
|
next larger power of two; for instance, a 50-Hz
|
|
(20 ms) or 60-Hz (16.67 ms) power-frequency clock
|
|
would be assigned the value -5 (31.25 ms), while a
|
|
1000-Hz (1 ms) crystal-controlled clock would be
|
|
assigned the value -9 (1.95 ms)."
|
|
::= { qtechntpSystem 3 }
|
|
|
|
qtechntpSysRootDelay OBJECT-TYPE
|
|
SYNTAX NTPSignedTimeValue
|
|
-- Rsyntax OCTET STRING(SIZE(4))
|
|
-- Units
|
|
-- seconds
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A signed fixed-point number indicating the total
|
|
round-trip delay in seconds, to the primary reference
|
|
source at the root of the synchronization subnet."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Sections 2.2, 3.2.1"
|
|
::= { qtechntpSystem 4 }
|
|
|
|
qtechntpSysRootDispersion OBJECT-TYPE
|
|
SYNTAX NTPUnsignedTimeValue
|
|
-- Rsyntax OCTET STRING(SIZE(4))
|
|
-- Units
|
|
-- seconds
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum error in seconds, relative to the
|
|
primary reference source at the root of the
|
|
synchronization subnet. Only positive values greater
|
|
than zero are possible."
|
|
REFERENCE
|
|
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
|
RFC-1305, March 1992, Sections 2, 2.2, 3.2.1"
|
|
::= { qtechntpSystem 5 }
|
|
|
|
qtechntpSysRefId OBJECT-TYPE
|
|
SYNTAX NTPRefId
|
|
-- Rsyntax OCTET STRING(SIZE(4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reference identifier of the local clock."
|
|
::= { qtechntpSystem 6 }
|
|
|
|
qtechntpSysRefTime OBJECT-TYPE
|
|
SYNTAX NTPTimeStamp
|
|
-- Rsyntax OCTET STRING(SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local time when the local clock was last
|
|
updated. If the local clock has never been
|
|
synchronized, the value is zero."
|
|
::= { qtechntpSystem 7 }
|
|
|
|
qtechNTPServerIPAdd OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NTP Server address."
|
|
::= { qtechntpSystem 8 }
|
|
|
|
qtechTimeAfterNTPCal OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time After NTP Call."
|
|
::= { qtechntpSystem 9 }
|
|
|
|
qtechTimeSyncPeriod OBJECT-TYPE
|
|
SYNTAX Integer32(0..8640000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time Sync Period."
|
|
::= { qtechntpSystem 10 }
|
|
|
|
-- ntp server table
|
|
qtechNtpServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF QtechNtpServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table about NTP server infomation."
|
|
::= { qtechntpSystem 11 }
|
|
|
|
qtechNtpServerEntry OBJECT-TYPE
|
|
SYNTAX QtechNtpServerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry of qtechNtpServerTable."
|
|
INDEX {
|
|
qtechNtpServerNetType,
|
|
qtechNtpServerNetAddr
|
|
}
|
|
::= { qtechNtpServerTable 1 }
|
|
|
|
QtechNtpServerEntry ::=
|
|
SEQUENCE {
|
|
qtechNtpServerNetType InetAddressType,
|
|
qtechNtpServerNetAddr InetAddress,
|
|
qtechNtpServerVersion INTEGER,
|
|
qtechNtpServerStatus RowStatus
|
|
}
|
|
|
|
qtechNtpServerNetType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Address type of NTP server:
|
|
ipv4(1),
|
|
ipv6(2)"
|
|
::= { qtechNtpServerEntry 1 }
|
|
|
|
qtechNtpServerNetAddr OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Address of NTP server."
|
|
::= { qtechNtpServerEntry 2 }
|
|
|
|
qtechNtpServerVersion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
version1(1),
|
|
version2(2),
|
|
version3(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version of NTP server."
|
|
::= { qtechNtpServerEntry 3 }
|
|
|
|
qtechNtpServerStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RowStatus of NTP server."
|
|
::= { qtechNtpServerEntry 4 }
|
|
|
|
|
|
-- compliance statements
|
|
qtechNtpSysGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
qtechntpSysLeap,
|
|
qtechntpSysStratum,
|
|
qtechntpSysPrecision,
|
|
qtechntpSysRootDelay,
|
|
qtechntpSysRootDispersion,
|
|
qtechntpSysRefId,
|
|
qtechntpSysRefTime,
|
|
qtechNTPServerIPAdd,
|
|
qtechTimeAfterNTPCal,
|
|
qtechTimeSyncPeriod,
|
|
qtechNtpServerNetType,
|
|
qtechNtpServerNetAddr,
|
|
qtechNtpServerVersion,
|
|
qtechNtpServerStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NTP system variables."
|
|
::= { qtechNtpMIBGroups 1 }
|
|
|
|
qtechNtpMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for agents which implement the NTP MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { qtechNtpMIBGroups
|
|
}
|
|
::= { qtechNtpMIBCompliances 1 }
|
|
|
|
END
|
|
|