Observium_CE/mibs/qtech/QTECH-NMS-SWITCH-MIB

356 lines
12 KiB
Plaintext

-- *****************************************************************
-- switch MIB - The MIB for switch Product
--
-- Copyright (c) 2009 by Co., Ltd.
-- All rights reserved.
-- *****************************************************************
-- ********************************************************************************
-- Log for switch MIB.
--
-- Jan 13 2009
-- 1. Add UserMacAddress
--
-- ********************************************************************************
QTECH-NMS-SWITCH-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE
FROM SNMPv2-SMI
Gauge,TimeTicks
FROM RFC1155-SMI
DisplayString
FROM RFC1213-MIB
nmsMgmt
FROM QTECH-NMS-SMI
PhysAddress,
RowStatus,
MacAddress,
TruthValue
FROM SNMPv2-TC
ifIndex
FROM IF-MIB
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB;
switchMIB MODULE-IDENTITY
LAST-UPDATED "200901130000Z"
ORGANIZATION ""
CONTACT-INFO
""
DESCRIPTION
"The MIB module to describe switch product."
::= { nmsMgmt 1 }
switchMIBObjects OBJECT IDENTIFIER ::= { switchMIB 1 }
switchSystem OBJECT IDENTIFIER ::= { switchMIBObjects 1 }
switchModules OBJECT IDENTIFIER ::= { switchMIBObjects 2 }
-- Port Security Table
portSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF portSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Port-based Security information,including security mode and max host setting."
::= { switchModules 1 }
portSecurityEntry OBJECT-TYPE
SYNTAX portSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing port security information."
INDEX {portSecurityModuleIndex,portSecurityPortIndex }
::= { portSecurityTable 1 }
portSecurityEntry ::= SEQUENCE {
portSecurityModuleIndex INTEGER,
portSecurityPortIndex INTEGER,
portSecurityMode INTEGER,
portSecurityMaxHostCapability INTEGER,
portSecurityMaxHost INTEGER
}
portSecurityModuleIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each
module. It is recommended that values are assigned
contiguously starting from 1. The value for each
interface sub-layer must remain constant at least from
one re-initialization of the entity's network
management system to the next re-initialization."
::= { portSecurityEntry 1 }
portSecurityPortIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each
port. It is recommended that values are assigned
contiguously starting from 1. The value for each
interface sub-layer must remain constant at least from
one re-initialization of the entity's network
management system to the next re-initialization."
::= { portSecurityEntry 2 }
portSecurityMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
dynamic(2),
static-accept(3),
static-reject(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The port security mode."
::= { portSecurityEntry 3 }
portSecurityMaxHostCapability OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum number hosts which can be allowed to be used."
::= { portSecurityEntry 4 }
portSecurityMaxHost OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum number hosts which can be allowed to be used.
a value bigger than portSecurityMaxHostCapability means
unlimited max-host value."
::= { portSecurityEntry 5 }
-- Port Security mac address Table
portSecurityMacAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF portSecurityMacAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of portSecurityMacAddressEntry entries.
The port-based security mac address information."
::= { switchModules 2 }
portSecurityMacAddressEntry OBJECT-TYPE
SYNTAX portSecurityMacAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing security mac address information.Useing the format
(port + space + mac address)to add a new mac address to a port.For example,'20 0013469905a9'
will add the mac address '0013.4699.05a9' to port 20.The switch will return a error symbol
to indicate a unsuccessful operation."
INDEX { portSecurityMacAddressPortIndex , portSecurityMacAddress}
::= { portSecurityMacAddressTable 1 }
portSecurityMacAddressEntry ::= SEQUENCE {
portSecurityMacAddressPortIndex INTEGER,
portSecurityMacAddress MacAddress,
portSecurityMacAddressDel TruthValue
--portSecurityMacAddressMaxNum INTEGER
}
portSecurityMacAddressPortIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each
port."
::= { portSecurityMacAddressEntry 1 }
portSecurityMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A unique string for mac address. Useing the format(port + space + mac address)
to add a new mac address to a port.For example,'20 0013469905a9'will add the mac address
'0013.4699.05a9' to port 20.The switch will return a error symbol to indicate a unsuccessful
operation."
::= { portSecurityMacAddressEntry 2}
portSecurityMacAddressDel OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "mac address cancel flag. True (1) delete the
mac address from a port."
::= { portSecurityMacAddressEntry 3 }
--portSecurityMacAddressMaxNum OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "The max number of security mac address can be applied to a port."
-- ::= { portSecurityMacAddressEntry 4 }
--
-- Lastest user MAC table
--
switchUserMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF switchUserMacEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of switchUserMacEntry entries."
::= { switchModules 11 }
switchUserMacEntry OBJECT-TYPE
SYNTAX switchUserMacEntry
MAX-ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing management information applicable
to a particular switch User mac address."
INDEX { userMacModuleIndex , userMacPortIndex }
::= { switchUserMacTable 1 }
switchUserMacEntry ::=
SEQUENCE {
userMacModuleIndex INTEGER,
userMacPortIndex INTEGER,
userMacAddress1 PhysAddress,
userMacAddress2 PhysAddress,
userMacAddress3 PhysAddress,
userMacAddress4 PhysAddress,
userMacAddress5 PhysAddress,
userMacAddress6 PhysAddress,
userMacAddress7 PhysAddress,
userMacAddress8 PhysAddress
}
userMacModuleIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each
module(Node). It is recommended that values are assigned
contiguously starting from 1."
::= { switchUserMacEntry 1 }
userMacPortIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each
port. It is recommended that values are assigned
contiguously starting from 1."
::= { switchUserMacEntry 2 }
userMacAddress1 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The first entry of lastest user mac address."
::= { switchUserMacEntry 3 }
userMacAddress2 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The second entry of lastest user mac address."
::= { switchUserMacEntry 4 }
userMacAddress3 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The third entry of lastest user mac address."
::= { switchUserMacEntry 5 }
userMacAddress4 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fourth entry of lastest user mac address."
::= { switchUserMacEntry 6 }
userMacAddress5 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fifth entry of lastest user mac address."
::= { switchUserMacEntry 7 }
userMacAddress6 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sixth entry of lastest user mac address."
::= { switchUserMacEntry 8 }
userMacAddress7 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The seventh entry of lastest user mac address."
::= { switchUserMacEntry 9 }
userMacAddress8 OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The eighth entry of lastest user mac address."
::= { switchUserMacEntry 10 }
cpuBandwidthTable OBJECT-TYPE
SYNTAX SEQUENCE OF cpuBandwidthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of cpu bandwidth table entries."
::= { switchSystem 2 }
cpuBandwidthEntry OBJECT-TYPE
SYNTAX cpuBandwidthEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A collection of additional objects in the cpu bandwidth table."
INDEX { cpuBandwidthQueueIndex }
::= { cpuBandwidthTable 1 }
cpuBandwidthEntry ::=
SEQUENCE {
cpuBandwidthQueueIndex INTEGER,
cpuBandwidthQueueBW INTEGER
}
cpuBandwidthQueueIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Queue id. The range is 1-8."
::= { cpuBandwidthEntry 1 }
cpuBandwidthQueueBW OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The rate limitation of cpu queue. Unit is 64kbps. The range is 1-1562. 0 means disable. Default is 0."
::= { cpuBandwidthEntry 2 }
END