Observium_CE/mibs/qtech/QTECH-GBNDeviceOEM-MIB

375 lines
13 KiB
Plaintext

QTECH-GBNDeviceOEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, Counter64 FROM SNMPv2-SMI
DisplayString, TruthValue FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
gbnDevice FROM QTECH-MASTER-MIB
PortList FROM Q-BRIDGE-MIB;
bcm5600 MODULE-IDENTITY
LAST-UPDATED "0105030000Z" -- May 03,2001
ORGANIZATION "QTECH LLC"
CONTACT-INFO "Basil Budko
E-mail: budko@qtech.ru"
DESCRIPTION "GBN Broadcom BCM5600 StrataSwitch OEM-Product
Enterprise MIB definition."
REVISION "0105030000Z" -- May 03,2001
DESCRIPTION "Initial MIB creation."
::= { gbnDevice 3 }
------------------------------------------------------------------------------
-- Textual Conventions (i.e., these do not affect object encoding):
------------------------------------------------------------------------------
--
-- "DURABLE":
-- Objects that are saved across a system reset and/or power cycle
-- are noted as "DURABLE" for convenience in the DESCRIPTION
-- section of the object definition. Code must be explicitly
-- written to implement these DURABLE objects.
--
------------------------------------------------------------------------------
-- define groups in OEM-BCM5600-MIB
------------------------------------------------------------------------------
oemArchIface OBJECT IDENTIFIER ::= { bcm5600 1 }
oemChip OBJECT IDENTIFIER ::= { bcm5600 2 }
oemProdConformance OBJECT IDENTIFIER ::= { bcm5600 3 }
oemProdGroups OBJECT IDENTIFIER ::= { oemProdConformance 1 }
oemProdCompliances OBJECT IDENTIFIER ::= { oemProdConformance 2 }
------------------------------------------------------------------------------
oemArchIfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF OemArchIfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of switch interfaces and associated properties."
::= { oemArchIface 1 }
oemArchIfaceEntry OBJECT-TYPE
SYNTAX OemArchIfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for switch interface control and status information."
INDEX { oemArchIfaceUnit, oemArchIfacePort }
::= { oemArchIfaceTable 1 }
OemArchIfaceEntry ::= SEQUENCE {
oemArchIfaceUnit Integer32,
oemArchIfacePort Integer32,
oemArchIfaceLLWHPort Integer32,
oemArchIfaceIfIndex Integer32,
oemArchIfaceName DisplayString,
oemArchIfaceEnable TruthValue,
oemArchIfaceSTPEnable TruthValue,
oemArchIfaceLink INTEGER,
oemArchIfaceDuplexSpeedSet INTEGER,
oemArchIfaceDuplexSpeedGet INTEGER,
oemArchIfacePortLoop INTEGER,
oemArchIfaceFlowControl INTEGER,
oemArchIfaceTxVlanTagPkts Counter64,
oemArchIfaceTxL3Pkts Counter64,
oemArchIfaceTxL3AbortedPkts Counter64,
oemArchIfaceRxIpInHdrErrors Counter64
}
oemArchIfaceUnit OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies a unit in the TiNet Switch
stack. If an invalid value is used for the index, a SNMP
'noSuchName' error (SNMPv1) or 'noSuchInstance' exception
(SNMPv2/v3) is returned. For implementations that do not support
stacking, the same response is returned for any unit index other
than 1."
::= { oemArchIfaceEntry 1 }
oemArchIfacePort OBJECT-TYPE
SYNTAX Integer32 (1..26)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies a GBN Application 'logical port'
(i.e., IEEE 802.3ad Aggregator) within the oemArchIfaceUnit."
::= { oemArchIfaceEntry 2 }
oemArchIfaceLLWHPort OBJECT-TYPE
SYNTAX Integer32 (8193..8296)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value that uniquely identifies a GBN Application 'logical port'
(i.e., IEEE 802.3ad Aggregator) in the GBN BCM5600 stack. This is
a 'Layered Linear With Holes' (LLWH) port number that may may have
holes for missing ports or units. For this MIB, 26 port numbers
are reserved for each unit in the stack. For example, LLHW port
8193 is unit 1, port 1 ."
::= { oemArchIfaceEntry 3 }
oemArchIfaceIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex of this GBN Application 'logical port' (i.e., IEEE
802.3ad Aggregator). Note that an ifIndex value of 34603009
(0x02100001) represents the Aggregator layer, unit 1, slot 0
(base unit ports), port 1."
::= { oemArchIfaceEntry 4 }
oemArchIfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE:
The textual name of this interface, e.g., 'John'."
::= { oemArchIfaceEntry 5 }
oemArchIfaceEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { true:all }
This object is true(1) when this interface is enabled and
false(1) when it is disabled. For this product, this is the
ONLY way to enable or disable this interface. Note that
'ifAdminStatus' in RFC1213 and RFC2233 and 'dot1dStpPortEnable'
in RFC1493 are each implemented as 'read-only'."
::= { oemArchIfaceEntry 6 }
oemArchIfaceSTPEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { true:all }
This object is true(1) when Spanning Tree operation is enabled
for this interface and false(2) when it is disabled."
::= { oemArchIfaceEntry 7 }
oemArchIfaceLink OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of Link Detect on this interface."
::= { oemArchIfaceEntry 8 }
oemArchIfaceDuplexSpeedSet OBJECT-TYPE
SYNTAX INTEGER {
autonegotiate(1),
half-10(2),
full-10(3),
half-100(4),
full-100(5),
half-1000(6),
full-1000(7),
auto-10(8),
auto-100(9),
auto-1000(10),
full-10000(11),
illegal(99)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { autonegotiate:all }
The desired speed and duplex for this interface. If the selected
control is not possible on the interface, a value of illegal(99)
is returned. If the port type does NOT support the default
of autonegotiate(1), then the application initializes the
port to a valid value (e.g., 1000full(6)). Note that not all
controls are possible for all interfaces. For example, only
full-1000(6) is available for Gigabit Ethernet interfaces."
::= { oemArchIfaceEntry 9 }
oemArchIfaceDuplexSpeedGet OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
half-10(2),
full-10(3),
half-100(4),
full-100(5),
half-1000(6),
full-1000(7),
auto_10(8),
auto_100(9),
auto_1000(10),
full-10000(11),
illegal(99)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual speed and duplex for this interface. If the
interface is not configured for an acceptable value, a value of
illegal(99) is returned. A value of unknown(1) is returned when
the 'oemArchIfaceLink' indicates down(2) for this interface."
::= { oemArchIfaceEntry 10 }
oemArchIfacePortLoop OBJECT-TYPE
SYNTAX INTEGER {
internalEnable(1),
externalEnable(2),
disable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The state of Link Detect on this interface."
::= { oemArchIfaceEntry 11 }
oemArchIfaceFlowControl OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE: { enable }
Set the flow control on the interface to enable(1) or disable(2)."
::= { oemArchIfaceEntry 12 }
oemArchIfaceTxVlanTagPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of VLAN tagged packets transmitted on this interface."
::= { oemArchIfaceEntry 13 }
oemArchIfaceTxL3Pkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Layer 3 packets transmitted on this interface."
::= { oemArchIfaceEntry 14 }
oemArchIfaceTxL3AbortedPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Layer 3 transmit packets aborted on this interface."
::= { oemArchIfaceEntry 15 }
oemArchIfaceRxIpInHdrErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Layer 3 packets received on this interface that
were discarded due to IP header errors (e.g., bad checksum,
invalid versions, format errors)."
::= { oemArchIfaceEntry 16 }
------------------------------------------------------------------------------
-- Chip Interface Section
------------------------------------------------------------------------------
--
oemChipStub OBJECT-TYPE
SYNTAX INTEGER {
noop(1),
chip-value2(2),
chip-value3(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a place holder for the OEM Chip interface."
::= { oemChip 1 }
------------------------------------------------------------------------------
------------------------------------------------------------------------------
-- conformance information
------------------------------------------------------------------------------
-- --------------------------------------------------------------------------
-- units of conformance
-- --------------------------------------------------------------------------
oemArchIfaceGroup OBJECT-GROUP
OBJECTS {
oemArchIfaceLLWHPort,
oemArchIfaceIfIndex,
oemArchIfaceName,
oemArchIfaceEnable,
oemArchIfaceSTPEnable,
oemArchIfaceLink,
oemArchIfaceDuplexSpeedSet,
oemArchIfaceDuplexSpeedGet,
oemArchIfacePortLoop,
oemArchIfaceFlowControl,
oemArchIfaceTxVlanTagPkts,
oemArchIfaceTxL3Pkts,
oemArchIfaceTxL3AbortedPkts,
oemArchIfaceRxIpInHdrErrors
}
STATUS current
DESCRIPTION
"This group configures and retrieves Architecture interface
specific objects."
::= { oemProdGroups 1 }
oemChipGroup OBJECT-GROUP
OBJECTS {
oemChipStub
}
STATUS current
DESCRIPTION
"This group configures OEM Chip specific objects."
::= { oemProdGroups 2 }
-- --------------------------------------------------------------------------
-- compliance statements
-- --------------------------------------------------------------------------
oemProdCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement."
MODULE -- this module
MANDATORY-GROUPS {
oemArchIfaceGroup
}
GROUP oemChipGroup
DESCRIPTION
"This group is optional."
::= { oemProdCompliances 1 }
--
-- END of OEM-BCM5600-MIB
--
END