-- Copyright (c) 2007, 2010, Oracle and/or its affiliates. All rights reserved.
|
|
--
|
|
|
|
SUN-HW-TRAP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, enterprises, Integer32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString, RowPointer
|
|
FROM SNMPv2-TC
|
|
OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
sun OBJECT IDENTIFIER ::= { enterprises 42 }
|
|
products OBJECT IDENTIFIER ::= { sun 2 }
|
|
ilom OBJECT IDENTIFIER ::= { products 175 }
|
|
|
|
sunHwTrapMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201005050000Z" -- May 5, 2010
|
|
ORGANIZATION "Oracle Corporation"
|
|
CONTACT-INFO "Oracle Corporation
|
|
Worldwide Headquarters
|
|
500 Oracle Parkway
|
|
Redwood Shores, CA 94065
|
|
U.S.A
|
|
|
|
http://www.oracle.com
|
|
or contact your local support representative"
|
|
DESCRIPTION
|
|
"Copyright (c) 2007, 2010, Oracle and/or its affiliates.
|
|
All rights reserved.
|
|
|
|
The SUN-HW-TRAP-MIB describes the hardware related
|
|
notifications/traps that may be generated by Oracle systems"
|
|
REVISION
|
|
"201005050000Z" -- May 5, 2010
|
|
DESCRIPTION
|
|
"Version: 2.4
|
|
Add sunHwTrapFaultDiagnosed trap"
|
|
REVISION
|
|
"200912040000Z" -- December 4, 2009
|
|
DESCRIPTION
|
|
"Version: 2.3
|
|
Add Storage and drive traps"
|
|
REVISION
|
|
"200909090000Z" -- September 9, 2009
|
|
DESCRIPTION
|
|
"Version: 2.2
|
|
Bug fix: missing varbinds in
|
|
sunHwTrapPowerConsumptionThresholdDeasserted"
|
|
REVISION
|
|
"200904170000Z" -- April 17, 2009
|
|
DESCRIPTION
|
|
"Version: 2.1
|
|
Released with ILOM version 3.0"
|
|
REVISION
|
|
"200810290000Z" -- October 29, 2008
|
|
DESCRIPTION
|
|
"Version: 1.1
|
|
Added keywords for HP SIM integration"
|
|
REVISION
|
|
"200702060000Z" -- February 6, 2007
|
|
DESCRIPTION
|
|
"Version: 1.0"
|
|
|
|
::= { ilom 103 }
|
|
|
|
sunHwTrapObjects OBJECT IDENTIFIER ::= { sunHwTrapMIB 1 }
|
|
sunHwTraps OBJECT IDENTIFIER ::= { sunHwTrapMIB 2 }
|
|
sunHwTrapPrefix OBJECT IDENTIFIER ::= { sunHwTraps 0 }
|
|
sunHwTrapData OBJECT IDENTIFIER ::= { sunHwTraps 1 }
|
|
sunHwTrapDataTables OBJECT IDENTIFIER ::= { sunHwTraps 2 }
|
|
sunHwTrapConformances OBJECT IDENTIFIER ::= { sunHwTrapMIB 3 }
|
|
sunHwTrapCompliances OBJECT IDENTIFIER ::= { sunHwTrapConformances 1 }
|
|
sunHwTrapGroups OBJECT IDENTIFIER ::= { sunHwTrapConformances 2 }
|
|
sunHwTrapObjectGroups OBJECT IDENTIFIER ::= { sunHwTrapGroups 1 }
|
|
sunHwTrapNotifGroups OBJECT IDENTIFIER ::= { sunHwTrapGroups 2 }
|
|
|
|
|
|
--
|
|
-- Textual Conventions
|
|
--
|
|
|
|
SunHwTrapThresholdTypeTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes whether a threshold is an upper threshold or
|
|
a lower threshold"
|
|
SYNTAX INTEGER {
|
|
upper(1),
|
|
lower(2),
|
|
unknown(3)
|
|
}
|
|
|
|
SunHwTrapSeverityTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the severity levels that a trap can take."
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
fatal(2),
|
|
critical(3),
|
|
nonCritical(4),
|
|
ok(5)
|
|
}
|
|
|
|
SunHwTrapHAStateTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the states that a high availability system can take."
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
initializing(2),
|
|
standalone(3),
|
|
standby(4),
|
|
master(5)
|
|
}
|
|
|
|
SunHwTrapHardDriveStatesTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the states a hard drive can be in when hard drive status
|
|
is reported."
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
present(2),
|
|
fault(3),
|
|
predictiveFailure(4),
|
|
hotSpare(5),
|
|
consistencyCheckInProgress(6),
|
|
inCriticalArray(7),
|
|
inFailedArray(8),
|
|
rebuildInProgress(9),
|
|
rebuildAborted(10)
|
|
}
|
|
|
|
SunHwTrapDisableReasonsTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the reasons that a component is disabled."
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
faultOrError(2),
|
|
configuration(3)
|
|
}
|
|
|
|
SunHwTrapFloatingPointValueTC ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "255a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A floating point number converted to a string
|
|
in decimal notation of the form [-]mmm.dd"
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
|
|
SunHwTrapHardDriveProbableCauseTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Probable cause for hard drive error"
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
reassignwriteoperationfailed(2),
|
|
unrecoverablemediumerrorduringrebuild(3),
|
|
badblocklogfull(4),
|
|
badblocklogalmostfull(5),
|
|
rebuildfailed(6),
|
|
globalsparecoverage(7),
|
|
uncorrectederror(10),
|
|
nonmediumerror(11),
|
|
selftestfailed(12),
|
|
smarthealthstatusfailed(13),
|
|
startstopmax(14)
|
|
}
|
|
|
|
SunHwTrapDriveControllerProbableCauseTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Probable cause for drive controller error"
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
fatalflasherror(2),
|
|
batterybackuperror(3),
|
|
fatalcacheerror(4),
|
|
controllerfailed(6)
|
|
}
|
|
|
|
SunHwTrapStorageVolumeProbableCauseTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Probable cause for storage volume error"
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
raidfailed(2),
|
|
raidmissing(3),
|
|
raiddegraded(4),
|
|
badblocklogfull(6),
|
|
raiderror(8)
|
|
}
|
|
|
|
SunHwTrapDiagEntityTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the entity that diagnosed the fault."
|
|
SYNTAX INTEGER {
|
|
fdd(1),
|
|
alomfm(2),
|
|
solarisfma(3),
|
|
other(4)
|
|
}
|
|
|
|
SunHwTrapSuspectFruStatusTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the status of a FRU."
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
suspected(2),
|
|
faulted(3),
|
|
repaired(4),
|
|
replaced(5),
|
|
acquitted(6)
|
|
}
|
|
|
|
--
|
|
-- MIB Notification specific data
|
|
--
|
|
|
|
sunHwTrapSystemIdentifier OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string used to identify the source of the trap. Typically
|
|
this is the host name."
|
|
::= { sunHwTrapData 1 }
|
|
|
|
sunHwTrapComponentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the component which is the source of the trap."
|
|
::= { sunHwTrapData 2 }
|
|
|
|
sunHwTrapThresholdType OBJECT-TYPE
|
|
SYNTAX SunHwTrapThresholdTypeTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the threshold type that the sensor is reporting on."
|
|
::= { sunHwTrapData 3 }
|
|
|
|
sunHwTrapThresholdValue OBJECT-TYPE
|
|
SYNTAX SunHwTrapFloatingPointValueTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The threshold setting that has been crossed."
|
|
::= { sunHwTrapData 4 }
|
|
|
|
sunHwTrapSensorValue OBJECT-TYPE
|
|
SYNTAX SunHwTrapFloatingPointValueTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The threshold sensor's reading at the time the trap was generated."
|
|
::= { sunHwTrapData 5 }
|
|
|
|
sunHwTrapSuspectComponentName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the name of a component that is suspected of causing
|
|
a fault."
|
|
::= { sunHwTrapData 6 }
|
|
|
|
sunHwTrapFaultClass OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The class represents a hierarchical classification string indicating
|
|
the type of problem detected, as reported by the fault management
|
|
subsystem, such as, for instance the Solaris fault manager.
|
|
Information on the Solaris fault manager can be found at
|
|
http://www.opensolaris.org/os/community/fm.
|
|
|
|
This object will have a value of NULL if the system doesn't
|
|
support this information."
|
|
REFERENCE
|
|
"SUN-FM-MIB.sunFmFaultEventClass
|
|
http://www.opensolaris.org/os/community/fm/mib/sun-fm-mib.mib"
|
|
|
|
::= { sunHwTrapData 7 }
|
|
|
|
sunHwTrapFaultCertainty OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage likelihood that the component is the source
|
|
of the problem. This object will have a value of 0 if the
|
|
system doesn't support this information."
|
|
::= { sunHwTrapData 8 }
|
|
|
|
sunHwTrapAdditionalInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An optional textual description which provides additional
|
|
information relevant to this notification."
|
|
::= { sunHwTrapData 9 }
|
|
|
|
sunHwTrapAssocObjectId OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object in the entPhysicalTable to which this notification applies.
|
|
The value is the name of the instance of the first accessible columnar
|
|
object in the entPhysicalTable conceptual row. If no association exists
|
|
or the association cannot be determined, this object will have a value
|
|
of 0.0."
|
|
::= { sunHwTrapData 10 }
|
|
|
|
sunHwTrapNewHAState OBJECT-TYPE
|
|
SYNTAX SunHwTrapHAStateTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides the new value of the high availability state
|
|
after a high availability state change has occurred."
|
|
::= { sunHwTrapData 11 }
|
|
|
|
sunHwTrapOldHAState OBJECT-TYPE
|
|
SYNTAX SunHwTrapHAStateTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides the old value of the high availability state
|
|
after a high availability state change has occurred."
|
|
::= { sunHwTrapData 12 }
|
|
|
|
sunHwTrapSeverity OBJECT-TYPE
|
|
SYNTAX SunHwTrapSeverityTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of the severity of the notfication."
|
|
::= { sunHwTrapData 13 }
|
|
|
|
sunHwTrapChassisId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string containing the chassis serial number. When combined
|
|
with the sunHwTrapProductName, it unambiguously identifies the
|
|
system. If the source of the trap is a blade, the text string will
|
|
contain the chassis serial number and the blade serial number, in
|
|
the following format <chassis-serial-number::blade-serial-number>"
|
|
::= { sunHwTrapData 14 }
|
|
|
|
sunHwTrapProductName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string containing the product name. When combined with the
|
|
sunHwTrapChassisId, it unambiguously identifies the system. If the
|
|
source of the trap is a blade, the text string will contain the
|
|
chassis product name and the blade product name, in the following
|
|
format <chassis-name>::<blade-name>"
|
|
::= { sunHwTrapData 15 }
|
|
|
|
sunHwTrapHardDriveState OBJECT-TYPE
|
|
SYNTAX SunHwTrapHardDriveStatesTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The states a hard drive can be in when hard drive status
|
|
is reported."
|
|
::= { sunHwTrapData 16 }
|
|
|
|
sunHwTrapFaultMessageID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The message ID that can be used to get additional information about
|
|
the problem from Sun's knowledge article database. This object will
|
|
have a value of NULL if the system doesn't support this
|
|
information."
|
|
::= { sunHwTrapData 17 }
|
|
|
|
sunHwTrapFaultUUID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The universal unique identifier that was assigned to this fault. This
|
|
object will have a value of NULL if the system doesn't support this
|
|
information."
|
|
::= { sunHwTrapData 18 }
|
|
|
|
sunHwTrapDisableReason OBJECT-TYPE
|
|
SYNTAX SunHwTrapDisableReasonsTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication as to why the component was disabled."
|
|
::= { sunHwTrapData 19 }
|
|
|
|
sunHwTrapTestMessage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a test trap"
|
|
::= { sunHwTrapData 20 }
|
|
|
|
sunHwTrapHardDriveProbableCause OBJECT-TYPE
|
|
SYNTAX SunHwTrapHardDriveProbableCauseTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Probable cause for hard drive error"
|
|
::= { sunHwTrapData 21 }
|
|
|
|
sunHwTrapDriveControllerProbableCause OBJECT-TYPE
|
|
SYNTAX SunHwTrapDriveControllerProbableCauseTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Probable cause for drive controller error"
|
|
::= { sunHwTrapData 22 }
|
|
|
|
sunHwTrapStorageVolumeProbableCause OBJECT-TYPE
|
|
SYNTAX SunHwTrapStorageVolumeProbableCauseTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Probable cause for storage volume error"
|
|
::= { sunHwTrapData 23 }
|
|
|
|
sunHwTrapEventTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time stamp for when the fault occurred."
|
|
::= { sunHwTrapData 24 }
|
|
|
|
sunHwTrapDiagEntity OBJECT-TYPE
|
|
SYNTAX SunHwTrapDiagEntityTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name and version of the software component that generated
|
|
this fault event."
|
|
::= { sunHwTrapData 25 }
|
|
|
|
sunHwTrapFaultDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description of the fault."
|
|
::= { sunHwTrapData 26 }
|
|
|
|
sunHwTrapKaUrl OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Knowledge article URL."
|
|
::= { sunHwTrapData 27 }
|
|
|
|
sunHwTrapSuspectCnt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of suspected faults diagnosed as the cause of
|
|
given set of reported hardware errors."
|
|
::= { sunHwTrapData 28 }
|
|
|
|
sunHwTrapHostname OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hostname of the SP or system"
|
|
::= { sunHwTrapData 29 }
|
|
|
|
sunHwTrapProductManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Product manufacturer"
|
|
::= { sunHwTrapData 30 }
|
|
|
|
sunHwTrapProductSn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Product serial number"
|
|
::= { sunHwTrapData 31 }
|
|
|
|
--
|
|
-- A table of diagnosed fault suspects
|
|
--
|
|
|
|
sunHwTrapSuspectTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SunHwTrapSuspectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of diagnosed fault suspects."
|
|
::= { sunHwTrapDataTables 1 }
|
|
|
|
sunHwTrapSuspectEntry OBJECT-TYPE
|
|
SYNTAX SunHwTrapSuspectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Suspect table entry."
|
|
INDEX { sunHwTrapSuspectFruIndex }
|
|
::= { sunHwTrapSuspectTable 1 }
|
|
|
|
SunHwTrapSuspectEntry ::= SEQUENCE {
|
|
sunHwTrapSuspectFruIndex Integer32,
|
|
sunHwTrapSuspectFruFaultCertainty Integer32,
|
|
sunHwTrapSuspectFruFaultClass DisplayString,
|
|
sunHwTrapSuspectFruName DisplayString,
|
|
sunHwTrapSuspectFruLocation DisplayString,
|
|
sunHwTrapSuspectFruChassisId DisplayString,
|
|
sunHwTrapSuspectFruManufacturer DisplayString,
|
|
sunHwTrapSuspectFruPn DisplayString,
|
|
sunHwTrapSuspectFruSn DisplayString,
|
|
sunHwTrapSuspectFruRevision DisplayString,
|
|
sunHwTrapSuspectFruStatus SunHwTrapSuspectFruStatusTC
|
|
}
|
|
|
|
sunHwTrapSuspectFruIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sequence number for suspect FRUs."
|
|
::= { sunHwTrapSuspectEntry 1 }
|
|
|
|
sunHwTrapSuspectFruFaultCertainty OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage likelihood that the fru is the source
|
|
of the problem. This object will have a value of 0 if the
|
|
system doesn't support this information."
|
|
::= { sunHwTrapSuspectEntry 2 }
|
|
|
|
sunHwTrapSuspectFruFaultClass OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The class represents a hierarchical classification string indicating
|
|
the type of problem detected, as reported by the fault management
|
|
subsystem, such as, for instance the Solaris fault manager.
|
|
Information on the Solaris fault manager can be found at
|
|
http://www.opensolaris.org/os/community/fm.
|
|
|
|
This object will have a value of NULL if the system doesn't
|
|
support this information."
|
|
REFERENCE
|
|
"SUN-FM-MIB.sunFmFaultEventClass
|
|
http://www.opensolaris.org/os/community/fm/mib/sun-fm-mib.mib"
|
|
|
|
::= { sunHwTrapSuspectEntry 3 }
|
|
|
|
sunHwTrapSuspectFruName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the suspect FRU."
|
|
::= { sunHwTrapSuspectEntry 4 }
|
|
|
|
sunHwTrapSuspectFruLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The location of the suspect FRU."
|
|
::= { sunHwTrapSuspectEntry 5 }
|
|
|
|
sunHwTrapSuspectFruChassisId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string containing the chassis serial number. When combined
|
|
with the sunHwTrapProductName, it unambiguously identifies the
|
|
system. If the source of the trap is a blade, the text string will
|
|
contain the chassis serial number and the blade serial number, in
|
|
the following format <chassis-serial-number::blade-serial-number>"
|
|
::= { sunHwTrapSuspectEntry 6 }
|
|
|
|
sunHwTrapSuspectFruManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the manufacturer of this FRU/CRU."
|
|
::= { sunHwTrapSuspectEntry 7 }
|
|
|
|
sunHwTrapSuspectFruPn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number used to order a FRU/CRU (i.e 501-7324-06)."
|
|
::= { sunHwTrapSuspectEntry 8 }
|
|
|
|
sunHwTrapSuspectFruSn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"18-character FRU serial number for this FRU/CRU
|
|
(i.e. 1005LCB-0725ZG01JE)."
|
|
::= { sunHwTrapSuspectEntry 9 }
|
|
|
|
sunHwTrapSuspectFruRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revision level."
|
|
::= { sunHwTrapSuspectEntry 10 }
|
|
|
|
sunHwTrapSuspectFruStatus OBJECT-TYPE
|
|
SYNTAX SunHwTrapSuspectFruStatusTC
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of FRU."
|
|
::= { sunHwTrapSuspectEntry 11 }
|
|
|
|
--
|
|
-- MIB Notifications
|
|
--
|
|
|
|
sunHwTrapVoltageFatalThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A voltage sensor has reported that its value has gone above an upper
|
|
fatal threshold setting or below a lower fatal threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A voltage sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A voltage sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
::= { sunHwTrapPrefix 1 }
|
|
|
|
sunHwTrapVoltageFatalThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A voltage sensor has reported that its value has gone below an upper
|
|
fatal threshold setting or above a lower fatal threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A voltage sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A voltage sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 2 }
|
|
|
|
sunHwTrapVoltageCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A voltage sensor has reported that its value has gone above an upper
|
|
critical threshold setting or below a lower critical threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A voltage sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A voltage sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 3 }
|
|
|
|
sunHwTrapVoltageCritThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A voltage sensor has reported that its value has gone below an upper
|
|
critical threshold setting or above a lower critical threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A voltage sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A voltage sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 4 }
|
|
|
|
sunHwTrapVoltageNonCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A voltage sensor has reported that its value has gone above an upper
|
|
non-critical threshold setting or below a lower non-critical threshold
|
|
setting. The sunHwTrapThresholdType object indicates whether the threshold
|
|
was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A voltage sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A voltage sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MINOR
|
|
::= { sunHwTrapPrefix 5 }
|
|
|
|
sunHwTrapVoltageOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A voltage sensor has reported that its value is in the normal
|
|
operating range."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A voltage sensor has reported that its value is in the normal operating range."
|
|
--#SUMMARY "A voltage sensor has reported that its value is in the normal operating range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 6 }
|
|
|
|
sunHwTrapTempFatalThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature sensor has reported that its value has gone above an upper
|
|
fatal threshold setting or below a lower fatal threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
::= { sunHwTrapPrefix 7 }
|
|
|
|
sunHwTrapTempFatalThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature sensor has reported that its value has gone below an
|
|
upper fatal threshold setting or above a lower fatal threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 8 }
|
|
|
|
sunHwTrapTempCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature sensor has reported that its value has gone above an
|
|
upper critical threshold setting or below a lower critical threshold
|
|
setting. The sunHwTrapThresholdType object indicates whether the
|
|
threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 9 }
|
|
|
|
sunHwTrapTempCritThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature sensor has reported that its value has gone below an
|
|
upper critical threshold setting or above a lower critical threshold
|
|
setting. The sunHwTrapThresholdType object indicates whether the
|
|
threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A temperature sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A temperature sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 10 }
|
|
|
|
sunHwTrapTempNonCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature sensor has reported that its value has gone above an
|
|
upper non-critical threshold setting or below a lower non-critical
|
|
threshold setting. The sunHwTrapThresholdType object indicates whether
|
|
the threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A temperature sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A temperature sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MINOR
|
|
::= { sunHwTrapPrefix 11 }
|
|
|
|
sunHwTrapTempOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature sensor has reported that its value is in the normal
|
|
operating range."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A temperature sensor has reported that its value is in the normal operating range."
|
|
--#SUMMARY "A temperature sensor has reported that its value is in the normal operating range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 12 }
|
|
|
|
sunHwTrapElectricalCurrentFatalThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An electrical current sensor has reported that its value has gone above
|
|
an upper fatal threshold setting or below a lower fatal threshold
|
|
setting. The sunHwTrapThresholdType object indicates whether the
|
|
threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An electrical current sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "An electrical current sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
::= { sunHwTrapPrefix 13 }
|
|
|
|
sunHwTrapElectricalCurrentFatalThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An electrical current sensor has reported that its value has gone below
|
|
an upper fatal threshold setting or above a lower fatal threshold
|
|
setting. The sunHwTrapThresholdType object indicates whether the
|
|
threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An electrical current sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "An electrical current sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 14 }
|
|
|
|
sunHwTrapElectricalCurrentCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An electrical current sensor has reported that its value has gone above
|
|
an upper critical threshold setting or below a lower critical threshold
|
|
setting. The sunHwTrapThresholdType object indicates whether the
|
|
threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An electrical current sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "An electrical current sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 15 }
|
|
|
|
sunHwTrapElectricalCurrentCritThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An electrical current sensor has reported that its value has gone below
|
|
an upper critical threshold setting or above a lower critical threshold
|
|
setting. The sunHwTrapThresholdType object indicates whether the
|
|
threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An electrical current sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "An electrical current sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 16 }
|
|
|
|
sunHwTrapElectricalCurrentNonCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An electrical current sensor has reported that its value has gone above
|
|
an upper non-critical threshold setting or below a lower non-critical
|
|
threshold setting. The sunHwTrapThresholdType object indicates whether
|
|
the threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An electrical current sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "An electrical current sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MINOR
|
|
::= { sunHwTrapPrefix 17 }
|
|
|
|
sunHwTrapElectricalCurrentOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An electrical current sensor has reported that its value is in
|
|
the normal operating range."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An electrical current sensor has reported that its value is in the normal operating range."
|
|
--#SUMMARY "An electrical current sensor has reported that its value is in the normal operating range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 18 }
|
|
|
|
sunHwTrapFanSpeedFatalThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan speed sensor has reported that its value has gone above an upper
|
|
fatal threshold setting or below a lower fatal threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan speed sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A fan speed sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
::= { sunHwTrapPrefix 19 }
|
|
|
|
sunHwTrapFanSpeedFatalThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan speed sensor has reported that its value has gone below an upper
|
|
fatal threshold setting or above a lower fatal threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan speed sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A fan speed sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 20 }
|
|
|
|
sunHwTrapFanSpeedCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan speed sensor has reported that its value has gone above an upper
|
|
critical threshold setting or below a lower critical threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan speed sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A fan speed sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 21 }
|
|
|
|
sunHwTrapFanSpeedCritThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan speed sensor has reported that its value has gone below an upper
|
|
critical threshold setting or above a lower critical threshold setting.
|
|
The sunHwTrapThresholdType object indicates whether the threshold was
|
|
an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan speed sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A fan speed sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 22 }
|
|
|
|
sunHwTrapFanSpeedNonCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan speed sensor has reported that its value has gone above an upper
|
|
non-critical threshold setting or below a lower non-critical threshold
|
|
setting. The sunHwTrapThresholdType object indicates whether the
|
|
threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan speed sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A fan speed sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MINOR
|
|
::= { sunHwTrapPrefix 23 }
|
|
|
|
sunHwTrapFanSpeedOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan speed sensor has reported that its value is in
|
|
the normal operating range."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan speed sensor has reported that its value is in the normal operating range."
|
|
--#SUMMARY "A fan speed sensor has reported that its value is in the normal operating range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 24 }
|
|
|
|
sunHwTrapSensorFatalThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has reported that its value has gone above an upper fatal
|
|
threshold setting or below a lower fatal threshold setting. The
|
|
generic 'sensor' trap is generated when the SNMP agent does not
|
|
recognize the component type. The sunHwTrapThresholdType object
|
|
indicates whether the threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
::= { sunHwTrapPrefix 25 }
|
|
|
|
sunHwTrapSensorFatalThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has reported that its value has gone below an upper fatal
|
|
threshold setting or above a lower fatal threshold setting. The
|
|
generic 'sensor' trap is generated when the SNMP agent does not
|
|
recognize the component type. The sunHwTrapThresholdType object
|
|
indicates whether the threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 26 }
|
|
|
|
sunHwTrapSensorCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has reported that its value has gone above an upper critical
|
|
threshold setting or below a lower critical threshold setting. The
|
|
generic 'sensor' trap is generated when the SNMP agent does not
|
|
recognize the component type. The sunHwTrapThresholdType object
|
|
indicates whether the threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 27 }
|
|
|
|
sunHwTrapSensorCritThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has reported that its value has gone below an upper critical
|
|
threshold setting or above a lower critical threshold setting. The
|
|
generic 'sensor' trap is generated when the SNMP agent does not
|
|
recognize the component type. The sunHwTrapThresholdType object
|
|
indicates whether the threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 28 }
|
|
|
|
sunHwTrapSensorNonCritThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has reported that its value has gone above an upper
|
|
non-critical threshold setting or below a lower non-critical threshold
|
|
setting. The generic 'sensor' trap is generated when the SNMP agent
|
|
does not recognize the component type. The sunHwTrapThresholdType
|
|
object indicates whether the threshold was an upper or lower."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#SUMMARY "A sensor has reported that its value has gone above an upper non-critical threshold setting or below a lower non-critical threshold setting. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MINOR
|
|
::= { sunHwTrapPrefix 29 }
|
|
|
|
sunHwTrapSensorThresholdOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has reported that its value is in the normal operating range.
|
|
The generic 'sensor' trap is generated when the SNMP agent does not
|
|
recognize the component type."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor has reported that its value is in the normal operating range. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#SUMMARY "A sensor has reported that its value is in the normal operating range. The generic 'sensor' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 30 }
|
|
|
|
sunHwTrapPowerSupplyFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power supply component is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A power supply component is suspected of causing a fault."
|
|
--#SUMMARY "A power supply component is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 31 }
|
|
|
|
sunHwTrapPowerSupplyFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power supply component fault has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A power supply component fault has been cleared."
|
|
--#SUMMARY "A power supply component fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 64 }
|
|
|
|
sunHwTrapPowerSupplyError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power supply sensor has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A power supply sensor has detected an error."
|
|
--#SUMMARY "A power supply sensor has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 32 }
|
|
|
|
sunHwTrapPowerSupplyOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power supply sensor has returned to its normal state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A power supply sensor has returned to its normal state."
|
|
--#SUMMARY "A power supply sensor has returned to its normal state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 33 }
|
|
|
|
sunHwTrapFanFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan component is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan component is suspected of causing a fault."
|
|
--#SUMMARY "A fan component is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 34 }
|
|
|
|
sunHwTrapFanFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan component fault has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan component fault has been cleared."
|
|
--#SUMMARY "A fan component fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 65 }
|
|
|
|
sunHwTrapFanError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan sensor has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan sensor has detected an error."
|
|
--#SUMMARY "A fan sensor has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 35 }
|
|
|
|
sunHwTrapFanOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A fan sensor has returned to its normal state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A fan sensor has returned to its normal state."
|
|
--#SUMMARY "A fan sensor has returned to its normal state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 36 }
|
|
|
|
sunHwTrapProcessorFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A processor component is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A processor component is suspected of causing a fault."
|
|
--#SUMMARY "A processor component is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 37 }
|
|
|
|
sunHwTrapProcessorFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A processor component fault has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A processor component fault has been cleared."
|
|
--#SUMMARY "A processor component fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 66 }
|
|
|
|
sunHwTrapProcessorError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A processor sensor has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A processor sensor has detected an error."
|
|
--#SUMMARY "A processor sensor has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 38 }
|
|
|
|
sunHwTrapProcessorOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A processor sensor has returned to its normal state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A processor sensor has returned to its normal state."
|
|
--#SUMMARY "A processor sensor has returned to its normal state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 39 }
|
|
|
|
sunHwTrapMemoryFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A memory component is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A memory component is suspected of causing a fault."
|
|
--#SUMMARY "A memory component is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 40 }
|
|
|
|
sunHwTrapMemoryFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A memory component fault has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A memory component fault has been cleared."
|
|
--#SUMMARY "A memory component fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 67 }
|
|
|
|
sunHwTrapMemoryError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A memory sensor has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A memory sensor has detected an error."
|
|
--#SUMMARY "A memory sensor has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 41 }
|
|
|
|
sunHwTrapMemoryOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A memory sensor has returned to its normal state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A memory sensor has returned to its normal state."
|
|
--#SUMMARY "A memory sensor has returned to its normal state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 42 }
|
|
|
|
sunHwTrapHardDriveFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapHardDriveProbableCause
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hard drive component is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A hard drive component is suspected of causing a fault."
|
|
--#SUMMARY "A hard drive component is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 43 }
|
|
|
|
sunHwTrapHardDriveFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hard drive component fault has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A hard drive component fault has been cleared."
|
|
--#SUMMARY "A hard drive component fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 68 }
|
|
|
|
sunHwTrapHardDriveError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapHardDriveProbableCause
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hard drive sensor has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A hard drive sensor has detected an error."
|
|
--#SUMMARY "A hard drive sensor has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 44 }
|
|
|
|
sunHwTrapHardDriveOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A hard drive sensor has returned to its normal state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A hard drive sensor has returned to its normal state."
|
|
--#SUMMARY "A hard drive sensor has returned to its normal state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 45 }
|
|
|
|
sunHwTrapIOFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A component in the IO subsystem is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A component in the IO subsystem is suspected of causing a fault."
|
|
--#SUMMARY "A component in the IO subsystem is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 46 }
|
|
|
|
sunHwTrapIOFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IO subsystem component fault has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An IO subsystem component fault has been cleared."
|
|
--#SUMMARY "An IO subsystem component fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 69 }
|
|
|
|
sunHwTrapIOError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IO sensor has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An IO sensor has detected an error."
|
|
--#SUMMARY "An IO sensor has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 47 }
|
|
|
|
sunHwTrapIOOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An IO sensor has returned to its normal state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An IO sensor has returned to its normal state."
|
|
--#SUMMARY "An IO sensor has returned to its normal state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 48 }
|
|
|
|
sunHwTrapSlotOrConnectorFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A slot or connector component is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A slot or connector component is suspected of causing a fault."
|
|
--#SUMMARY "A slot or connector component is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 49 }
|
|
|
|
sunHwTrapSlotOrConnectorFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A slot or connector component fault has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A slot or connector component fault has been cleared."
|
|
--#SUMMARY "A slot or connector component fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 70 }
|
|
|
|
sunHwTrapSlotOrConnectorError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor associated with a slot or connector has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor associated with a slot or connector has detected an error."
|
|
--#SUMMARY "A sensor associated with a slot or connector has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 50 }
|
|
|
|
sunHwTrapSlotOrConnectorOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor associated with a slot or connector has returned
|
|
to its normal state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor associated with a slot or connector has returned to its normal state."
|
|
--#SUMMARY "A sensor associated with a slot or connector has returned to its normal state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 51 }
|
|
|
|
sunHwTrapComponentFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A component is suspected of causing a fault. This generic 'component'
|
|
trap is generated when the SNMP agent does not recognize the component
|
|
type."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A component is suspected of causing a fault. This generic 'component' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#SUMMARY "A component is suspected of causing a fault. This generic 'component' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 52 }
|
|
|
|
sunHwTrapComponentFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A component fault has been cleared. This generic 'component'
|
|
trap is generated when the SNMP agent does not recognize the component
|
|
type."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A component fault has been cleared. This generic 'component' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#SUMMARY "A component fault has been cleared. This generic 'component' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 71 }
|
|
|
|
sunHwTrapComponentError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has detected an error. This generic 'component' trap is
|
|
generated when the SNMP agent does not recognize the component type."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor has detected an error. This generic 'component' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#SUMMARY "A sensor has detected an error. This generic 'component' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 53 }
|
|
|
|
sunHwTrapComponentOk NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A sensor has returned to its normal state. This generic 'component'
|
|
trap is generated when the SNMP agent does not recognize the component
|
|
type."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A sensor has returned to its normal state. This generic 'component' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#SUMMARY "A sensor has returned to its normal state. This generic 'component' trap is generated when the SNMP agent does not recognize the component type."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 54 }
|
|
|
|
sunHwTrapFruInserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A field replaceable unit has been inserted into the system."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A field replaceable unit has been inserted into the system."
|
|
--#SUMMARY "A field replaceable unit has been inserted into the system."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 55 }
|
|
|
|
sunHwTrapFruRemoved NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A field replaceable unit has been removed from the system."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A field replaceable unit has been removed from the system."
|
|
--#SUMMARY "A field replaceable unit has been removed from the system."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 56 }
|
|
|
|
sunHwTrapComponentDisabled NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapDisableReason,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component operational state has changed or is changing
|
|
to disabled."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "The component operational state has changed or is changing to disabled."
|
|
--#SUMMARY "The component operational state has changed or is changing to disabled."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 57 }
|
|
|
|
sunHwTrapComponentEnabled NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component operational state has changed or is changing
|
|
to enabled."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "The component operational state has changed or is changing to enabled."
|
|
--#SUMMARY "The component operational state has changed or is changing to enabled."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 58 }
|
|
|
|
sunHwTrapPreOSError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An error has been detected in the period before the operating
|
|
system has taken control of the system."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An error has been detected in the period before the operating system has taken control of the system."
|
|
--#SUMMARY "An error has been detected in the period before the operating system has taken control of the system."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 59 }
|
|
|
|
sunHwTrapHAStateChange NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapNewHAState,
|
|
sunHwTrapOldHAState,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The high availability component identified by sunHwTrapSystemIdentifier
|
|
has changed state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "The high availability component identified by sunHwTrapSystemIdentifier has changed state."
|
|
--#SUMMARY "The high availability component identified by sunHwTrapSystemIdentifier has changed state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 60 }
|
|
|
|
sunHwTrapSecurityIntrusion NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An intrusion sensor has detected that someone may have physically
|
|
tampered with the system."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "An intrusion sensor has detected that someone may have physically tampered with the system."
|
|
--#SUMMARY "An intrusion sensor has detected that someone may have physically tampered with the system."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 61 }
|
|
|
|
sunHwTrapHardDriveStatus NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapHardDriveState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hard drive identified by sunHwTrapComponentName has changed state."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "The hard drive identified by sunHwTrapComponentName has changed state."
|
|
--#SUMMARY "The hard drive identified by sunHwTrapComponentName has changed state."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 62 }
|
|
|
|
sunHwTrapTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapTestMessage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a test trap"
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "This is a test trap"
|
|
--#SUMMARY "This is a test trap"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 63 }
|
|
|
|
sunHwTrapPowerConsumptionThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power consumption threshold has been exceeded."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A power consumption threshold has been exceeded."
|
|
--#SUMMARY "A power consumption threshold has been exceeded."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 72 }
|
|
|
|
sunHwTrapPowerConsumptionThresholdDeasserted NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapSeverity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A power consumption threshold has been deasserted."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A power consumption threshold has been deasserted."
|
|
--#SUMMARY "A power consumption threshold has been deasserted."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 73 }
|
|
|
|
sunHwTrapDriveControllerFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapDriveControllerProbableCause
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A drive controller component is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A drive controller component is suspected of causing a fault."
|
|
--#SUMMARY "A drive controller component is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 74 }
|
|
|
|
sunHwTrapDriveControllerFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A drive controller has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A drive controller fault has been cleared."
|
|
--#SUMMARY "A drive controller fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 75 }
|
|
|
|
sunHwTrapDriveControllerError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapDriveControllerProbableCause
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A drive controller sensor has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A drive controller sensor has detected an error."
|
|
--#SUMMARY "A drive controller sensor has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 76 }
|
|
|
|
|
|
sunHwTrapStorageVolumeFault NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapStorageVolumeProbableCause
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A RAID component is suspected of causing a fault."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A drive controller component is suspected of causing a fault."
|
|
--#SUMMARY "A drive controller component is suspected of causing a fault."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 77 }
|
|
|
|
sunHwTrapStorageVolumeFaultCleared NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A storage volume fault has been cleared."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A storage volume fault has been cleared."
|
|
--#SUMMARY "A storage volume fault has been cleared."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= { sunHwTrapPrefix 78 }
|
|
|
|
sunHwTrapStorageVolumeError NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapSystemIdentifier,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapStorageVolumeProbableCause
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A RAID sensor has detected an error."
|
|
-- Keywords for HP SIM integration
|
|
--#TYPE "A RAID sensor has detected an error."
|
|
--#SUMMARY "A RAID sensor has detected an error."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
::= { sunHwTrapPrefix 79 }
|
|
|
|
sunHwTrapFaultDiagnosed NOTIFICATION-TYPE
|
|
OBJECTS { sunHwTrapEventTime,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapKaUrl,
|
|
sunHwTrapFaultDescription,
|
|
sunHwTrapSeverity,
|
|
sunHwTrapProductManufacturer,
|
|
sunHwTrapProductName,
|
|
sunHwTrapProductSn,
|
|
sunHwTrapDiagEntity,
|
|
sunHwTrapSystemIdentifier,
|
|
sunHwTrapHostname,
|
|
sunHwTrapSuspectCnt,
|
|
|
|
sunHwTrapSuspectFruFaultCertainty,
|
|
sunHwTrapSuspectFruFaultClass,
|
|
sunHwTrapSuspectFruName,
|
|
sunHwTrapSuspectFruLocation,
|
|
sunHwTrapSuspectFruChassisId,
|
|
sunHwTrapSuspectFruManufacturer,
|
|
sunHwTrapSuspectFruPn,
|
|
sunHwTrapSuspectFruSn,
|
|
sunHwTrapSuspectFruRevision,
|
|
sunHwTrapSuspectFruStatus,
|
|
|
|
sunHwTrapSuspectFruFaultCertainty,
|
|
sunHwTrapSuspectFruFaultClass,
|
|
sunHwTrapSuspectFruName,
|
|
sunHwTrapSuspectFruLocation,
|
|
sunHwTrapSuspectFruChassisId,
|
|
sunHwTrapSuspectFruManufacturer,
|
|
sunHwTrapSuspectFruPn,
|
|
sunHwTrapSuspectFruSn,
|
|
sunHwTrapSuspectFruRevision,
|
|
sunHwTrapSuspectFruStatus,
|
|
|
|
sunHwTrapSuspectFruFaultCertainty,
|
|
sunHwTrapSuspectFruFaultClass,
|
|
sunHwTrapSuspectFruName,
|
|
sunHwTrapSuspectFruLocation,
|
|
sunHwTrapSuspectFruChassisId,
|
|
sunHwTrapSuspectFruManufacturer,
|
|
sunHwTrapSuspectFruPn,
|
|
sunHwTrapSuspectFruSn,
|
|
sunHwTrapSuspectFruRevision,
|
|
sunHwTrapSuspectFruStatus,
|
|
|
|
sunHwTrapSuspectFruFaultCertainty,
|
|
sunHwTrapSuspectFruFaultClass,
|
|
sunHwTrapSuspectFruName,
|
|
sunHwTrapSuspectFruLocation,
|
|
sunHwTrapSuspectFruChassisId,
|
|
sunHwTrapSuspectFruManufacturer,
|
|
sunHwTrapSuspectFruPn,
|
|
sunHwTrapSuspectFruSn,
|
|
sunHwTrapSuspectFruRevision,
|
|
sunHwTrapSuspectFruStatus,
|
|
|
|
sunHwTrapSuspectFruFaultCertainty,
|
|
sunHwTrapSuspectFruFaultClass,
|
|
sunHwTrapSuspectFruName,
|
|
sunHwTrapSuspectFruLocation,
|
|
sunHwTrapSuspectFruChassisId,
|
|
sunHwTrapSuspectFruManufacturer,
|
|
sunHwTrapSuspectFruPn,
|
|
sunHwTrapSuspectFruSn,
|
|
sunHwTrapSuspectFruRevision,
|
|
sunHwTrapSuspectFruStatus
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Diagnosed fault has been detected.
|
|
Objects common to all suspects:
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapKaUrl,
|
|
sunHwTrapFaultDescription,
|
|
sunHwTrapSeverity,
|
|
sunHwTrapProductManufacturer,
|
|
sunHwTrapProductName,
|
|
sunHwTrapProductSn,
|
|
sunHwTrapDiagEntity,
|
|
sunHwTrapSystemIdentifier,
|
|
sunHwTrapHostname,
|
|
sunHwTrapSuspectCnt,
|
|
|
|
List of suspects objects:
|
|
sunHwTrapSuspectFruFaultCertainty
|
|
sunHwTrapSuspectFruFaultClass
|
|
sunHwTrapSuspectFruName
|
|
sunHwTrapSuspectFruLocation
|
|
sunHwTrapSuspectFruChassisId
|
|
sunHwTrapSuspectFruManufacturer
|
|
sunHwTrapSuspectFruPn
|
|
sunHwTrapSuspectFruSn
|
|
sunHwTrapSuspectFruRevision
|
|
sunHwTrapSuspectFruStatus"
|
|
|
|
::= { sunHwTrapPrefix 80 }
|
|
|
|
--
|
|
-- Object Groups
|
|
--
|
|
|
|
sunHwTrapNotificationObjectGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
sunHwTrapSystemIdentifier,
|
|
sunHwTrapComponentName,
|
|
sunHwTrapThresholdType,
|
|
sunHwTrapThresholdValue,
|
|
sunHwTrapSensorValue,
|
|
sunHwTrapSuspectComponentName,
|
|
sunHwTrapFaultClass,
|
|
sunHwTrapFaultCertainty,
|
|
sunHwTrapAdditionalInfo,
|
|
sunHwTrapAssocObjectId,
|
|
sunHwTrapNewHAState,
|
|
sunHwTrapOldHAState,
|
|
sunHwTrapSeverity,
|
|
sunHwTrapChassisId,
|
|
sunHwTrapProductName,
|
|
sunHwTrapHardDriveState,
|
|
sunHwTrapFaultMessageID,
|
|
sunHwTrapFaultUUID,
|
|
sunHwTrapDisableReason,
|
|
sunHwTrapTestMessage,
|
|
sunHwTrapHardDriveProbableCause,
|
|
sunHwTrapDriveControllerProbableCause,
|
|
sunHwTrapStorageVolumeProbableCause,
|
|
sunHwTrapEventTime,
|
|
sunHwTrapDiagEntity,
|
|
sunHwTrapKaUrl,
|
|
sunHwTrapFaultDescription,
|
|
sunHwTrapHostname,
|
|
sunHwTrapProductManufacturer,
|
|
sunHwTrapProductSn,
|
|
sunHwTrapSuspectCnt,
|
|
sunHwTrapSuspectFruFaultCertainty,
|
|
sunHwTrapSuspectFruFaultClass,
|
|
sunHwTrapSuspectFruName,
|
|
sunHwTrapSuspectFruLocation,
|
|
sunHwTrapSuspectFruChassisId,
|
|
sunHwTrapSuspectFruManufacturer,
|
|
sunHwTrapSuspectFruPn,
|
|
sunHwTrapSuspectFruSn,
|
|
sunHwTrapSuspectFruRevision,
|
|
sunHwTrapSuspectFruStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used in notifications."
|
|
::= { sunHwTrapObjectGroups 2 }
|
|
|
|
--
|
|
-- Notification Groups
|
|
--
|
|
|
|
sunHwTrapNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
sunHwTrapVoltageFatalThresholdExceeded,
|
|
sunHwTrapVoltageFatalThresholdDeasserted,
|
|
sunHwTrapVoltageCritThresholdExceeded,
|
|
sunHwTrapVoltageCritThresholdDeasserted,
|
|
sunHwTrapVoltageNonCritThresholdExceeded,
|
|
sunHwTrapVoltageOk,
|
|
sunHwTrapTempFatalThresholdExceeded,
|
|
sunHwTrapTempFatalThresholdDeasserted,
|
|
sunHwTrapTempCritThresholdExceeded,
|
|
sunHwTrapTempCritThresholdDeasserted,
|
|
sunHwTrapTempNonCritThresholdExceeded,
|
|
sunHwTrapTempOk,
|
|
sunHwTrapElectricalCurrentFatalThresholdExceeded,
|
|
sunHwTrapElectricalCurrentFatalThresholdDeasserted,
|
|
sunHwTrapElectricalCurrentCritThresholdExceeded,
|
|
sunHwTrapElectricalCurrentCritThresholdDeasserted,
|
|
sunHwTrapElectricalCurrentNonCritThresholdExceeded,
|
|
sunHwTrapElectricalCurrentOk,
|
|
sunHwTrapFanSpeedFatalThresholdExceeded,
|
|
sunHwTrapFanSpeedFatalThresholdDeasserted,
|
|
sunHwTrapFanSpeedCritThresholdExceeded,
|
|
sunHwTrapFanSpeedCritThresholdDeasserted,
|
|
sunHwTrapFanSpeedNonCritThresholdExceeded,
|
|
sunHwTrapFanSpeedOk,
|
|
sunHwTrapSensorFatalThresholdExceeded,
|
|
sunHwTrapSensorFatalThresholdDeasserted,
|
|
sunHwTrapSensorCritThresholdExceeded,
|
|
sunHwTrapSensorCritThresholdDeasserted,
|
|
sunHwTrapSensorNonCritThresholdExceeded,
|
|
sunHwTrapSensorThresholdOk,
|
|
sunHwTrapPowerSupplyFault,
|
|
sunHwTrapPowerSupplyFaultCleared,
|
|
sunHwTrapPowerSupplyError,
|
|
sunHwTrapPowerSupplyOk,
|
|
sunHwTrapFanFault,
|
|
sunHwTrapFanFaultCleared,
|
|
sunHwTrapFanError,
|
|
sunHwTrapFanOk,
|
|
sunHwTrapProcessorFault,
|
|
sunHwTrapProcessorFaultCleared,
|
|
sunHwTrapProcessorError,
|
|
sunHwTrapProcessorOk,
|
|
sunHwTrapMemoryFault,
|
|
sunHwTrapMemoryFaultCleared,
|
|
sunHwTrapMemoryError,
|
|
sunHwTrapMemoryOk,
|
|
sunHwTrapHardDriveFault,
|
|
sunHwTrapHardDriveFaultCleared,
|
|
sunHwTrapHardDriveError,
|
|
sunHwTrapHardDriveOk,
|
|
sunHwTrapIOFault,
|
|
sunHwTrapIOFaultCleared,
|
|
sunHwTrapIOError,
|
|
sunHwTrapIOOk,
|
|
sunHwTrapSlotOrConnectorFault,
|
|
sunHwTrapSlotOrConnectorFaultCleared,
|
|
sunHwTrapSlotOrConnectorError,
|
|
sunHwTrapSlotOrConnectorOk,
|
|
sunHwTrapComponentFault,
|
|
sunHwTrapComponentFaultCleared,
|
|
sunHwTrapComponentError,
|
|
sunHwTrapComponentOk,
|
|
sunHwTrapFruInserted,
|
|
sunHwTrapFruRemoved,
|
|
sunHwTrapComponentDisabled,
|
|
sunHwTrapComponentEnabled,
|
|
sunHwTrapPreOSError,
|
|
sunHwTrapHAStateChange,
|
|
sunHwTrapSecurityIntrusion,
|
|
sunHwTrapHardDriveStatus,
|
|
sunHwTrapTestTrap,
|
|
sunHwTrapPowerConsumptionThresholdExceeded,
|
|
sunHwTrapPowerConsumptionThresholdDeasserted,
|
|
sunHwTrapDriveControllerFault,
|
|
sunHwTrapDriveControllerFaultCleared,
|
|
sunHwTrapDriveControllerError,
|
|
sunHwTrapStorageVolumeFault,
|
|
sunHwTrapStorageVolumeFaultCleared,
|
|
sunHwTrapStorageVolumeError,
|
|
sunHwTrapFaultDiagnosed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of notifications used to indicate faults, errors,
|
|
and other conditions related to HW components in the system."
|
|
::= { sunHwTrapNotifGroups 1 }
|
|
|
|
END
|
|
|