Observium_CE/mibs/oneaccess/OneAccess-RoundTripTime-MIB

1718 lines
44 KiB
Plaintext

-- *****************************
-- * *
-- * ONEOS MIB *
-- * *
-- *****************************
--
-- ONEOS_MIB_STD_V05.1.R005_E001
--
-- Creation date : 18/09/2003
-- jitter table added 26/01/2004
--
-- Add of oacRttAppl : 29/03/2004
--
-- Change DESCRIPTION for oacRttControlTimeout : 20/04/2004
--
-- Add description for objects 30/03/06
--
OneAccess-RoundTripTime-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, Counter32, Gauge32, TimeTicks
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
DisplayString, TruthValue, RowStatus,
TimeInterval, TimeStamp, TEXTUAL-CONVENTION
FROM SNMPv2-TC
OwnerString
FROM IF-MIB
oacMIBModules, oacExpIMManagement
FROM ONEACCESS-GLOBAL-REG
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB; -- RFC2851
oacRttChkMIB MODULE-IDENTITY
LAST-UPDATED "201107290000Z"
ORGANIZATION " OneAccess "
CONTACT-INFO
"Pascal KESTELOOT
Postal: ONE ACCESS
381 Avenue du Général de Gaulle
92140 Clamart, France
FRANCE
Tel: (+33) 01 41 87 70 00
Fax: (+33) 01 41 87 74 00
E-mail: pascal.kesteloot@oneaccess-net.com"
DESCRIPTION
"fixed compilation issues"
REVISION "201107290000Z"
DESCRIPTION
"Contact updated"
REVISION "201106150000Z"
DESCRIPTION
"Fixed minor corrections."
REVISION "201007081000Z"
DESCRIPTION
"This MIB module describes a MIB for watching a
list of hosts using different protocols for Round
Trip Time(RTT)"
::= { oacExpIMManagement 1223 }
RttResponseSense ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Values for status of the operation."
SYNTAX INTEGER
{
ok(1),
disconnected(2),
overThreshold(3),
timeout(4),
busy(5),
notConnected(6),
dropped(7),
sequenceError(8),
verifyError(9),
applicationSpecific(10),
error(16)
}
OacRttRttType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Describe the type of operation to execute."
SYNTAX INTEGER
{
echo(1),
pathEcho(2)
}
OacRttProtocol ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Describe the protocol to be used for operation."
SYNTAX INTEGER
{
notApplicable(1),
ipIcmpEcho(2)
}
OacRttTargetAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Target address"
SYNTAX OCTET STRING
oacRttChkObj OBJECT IDENTIFIER ::= { oacRttChkMIB 1 }
oacRttControl OBJECT IDENTIFIER ::= { oacRttChkObj 1 }
oacRttHistory OBJECT IDENTIFIER ::= { oacRttChkObj 2 }
oacRttStats OBJECT IDENTIFIER ::= { oacRttChkObj 3 }
oacRttAppl OBJECT IDENTIFIER ::= { oacRttChkObj 4 }
oacRttApplVersion OBJECT-TYPE
SYNTAX DisplayString
-- Rsyntax OCTET STRING(SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version"
::= { oacRttAppl 1 }
----------------------------------------------------------------------
----------------------------------------------------------------------
----------------------------------------------------------------------
OacRttApplType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Values for Rtt Application Type."
SYNTAX INTEGER
{
echo(1),
pathEcho(2),
fileIO(3),
script(4),
udpEcho(5),
tcpConnect(6),
http(7),
dns(8),
jitter(9),
dlsw(10),
dhcp(11),
ftp(12)
}
OacRttApplProtocol ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Values for Rtt Application Protocol."
SYNTAX INTEGER
{
notApplicable(1),
ipIcmpEcho(2),
ipUdpEchoAppl(3),
snaRUEcho(4),
snaLU0EchoAppl(5),
snaLU2EchoAppl(6),
snaLU62Echo(7),
snaLU62EchoAppl(8),
appleTalkEcho(9),
appleTalkEchoAppl(10),
decNetEcho(11),
decNetEchoAppl(12),
ipxEcho(13),
ipxEchoAppl(14),
isoClnsEcho(15),
isoClnsEchoAppl(16),
vinesEcho(17),
vinesEchoAppl(18),
xnsEcho(19),
xnsEchoAppl(20),
apolloEcho(21),
apolloEchoAppl(22),
netbiosEchoAppl(23),
ipTcpConn(24),
httpAppl(25),
dnsAppl(26),
jitterAppl(27),
dlswAppl(28),
dhcpAppl(29),
ftpAppl(30)
}
oacRttApplSuppRttTypesTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttApplSuppRttTypesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of which contains the supported Rtt
Monitor Types."
::= { oacRttAppl 2 }
oacRttApplSuppRttTypesEntry OBJECT-TYPE
SYNTAX OacRttApplSuppRttTypesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Define valid Rtt Monitor types."
INDEX { oacRttApplSuppRttTypes }
::= { oacRttApplSuppRttTypesTable 1 }
OacRttApplSuppRttTypesEntry ::= SEQUENCE {
oacRttApplSuppRttTypes OacRttApplType,
oacRttApplSuppRttTypesValid TruthValue
}
oacRttApplSuppRttTypes OBJECT-TYPE
SYNTAX OacRttApplType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indexes the supported
'RttType' types."
::= { oacRttApplSuppRttTypesEntry 1 }
oacRttApplSuppRttTypesValid OBJECT-TYPE
SYNTAX TruthValue
-- INTEGER {
-- true(1),
-- false(2)
-- }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the supported
'RttMonRttType' types."
::= { oacRttApplSuppRttTypesEntry 2 }
oacRttApplSuppProtocolsTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttApplSuppProtocolsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of which contains the supported Rtt
Monitor Protocols."
::= { oacRttAppl 3 }
oacRttApplSuppProtocolsEntry OBJECT-TYPE
SYNTAX OacRttApplSuppProtocolsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list that presents the valid Rtt Monitor
Protocols."
INDEX { oacRttApplSuppProtocols }
::= { oacRttApplSuppProtocolsTable 1 }
OacRttApplSuppProtocolsEntry ::= SEQUENCE {
oacRttApplSuppProtocols OacRttApplProtocol ,
oacRttApplSuppProtocolsValid TruthValue
}
oacRttApplSuppProtocols OBJECT-TYPE
SYNTAX OacRttApplProtocol
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indexes the supported
'oacRttProtocol' protocols."
::= { oacRttApplSuppProtocolsEntry 1 }
oacRttApplSuppProtocolsValid OBJECT-TYPE
SYNTAX TruthValue
-- INTEGER {
-- true(1),
-- false(2)
-- }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the supported
'oacRttProtocol' protocols."
::= { oacRttApplSuppProtocolsEntry 2 }
----------------------------------------------------------------------
----------------------------------------------------------------------
----------------------------------------------------------------------
oacRttControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Definitions for RTT operations."
::= { oacRttControl 1 }
oacRttControlEntry OBJECT-TYPE
SYNTAX OacRttControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of objetcts defining a conceptual RTT operation."
INDEX { oacRttControlIndex }
::= { oacRttControlTable 1 }
OacRttControlEntry ::= SEQUENCE
{
oacRttControlIndex Integer32,
oacRttControlStatus RowStatus,
oacRttControlTag DisplayString,
oacRttControlFrequency Integer32,
oacRttControlRttType OacRttRttType,
oacRttControlTimeout Integer32,
oacRttControlOwner OwnerString,
oacRttControlThreshold Integer32
}
oacRttControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies a RTT row in oacRttControlTable."
::= { oacRttControlEntry 1 }
oacRttControlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the RTT row."
::= { oacRttControlEntry 2 }
oacRttControlTag OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"String used only by application for identify the row."
DEFVAL { "" }
::= { oacRttControlEntry 3 }
oacRttControlFrequency OBJECT-TYPE
SYNTAX Integer32 (0..604800)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Define frequency in seconds of RTT operations."
DEFVAL { 60 }
::= { oacRttControlEntry 4 }
oacRttControlRttType OBJECT-TYPE
SYNTAX OacRttRttType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Define type of RTT operation."
DEFVAL { echo }
::= { oacRttControlEntry 5 }
oacRttControlTimeout OBJECT-TYPE
SYNTAX Integer32 (0..604800000)
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines the timeout for an operation. It must be
set to a smaller value then oacRttControlFrequency*1000"
DEFVAL { 5000 }
::= { oacRttControlEntry 6 }
oacRttControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the creator of the row."
DEFVAL { "" }
::= { oacRttControlEntry 7 }
oacRttControlThreshold OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Define threshold limit."
DEFVAL { 5000 }
::= { oacRttControlEntry 8 }
oacRttEchoTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttEchoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table with definitions for an RTT entry."
::= { oacRttControl 2 }
oacRttEchoEntry OBJECT-TYPE
SYNTAX OacRttEchoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of objects for RTT entry configuration."
INDEX { oacRttControlIndex }
::= { oacRttEchoTable 1 }
OacRttEchoEntry ::= SEQUENCE
{
oacRttEchoSourceAddress OacRttTargetAddress,
oacRttEchoTargetAddress OacRttTargetAddress,
oacRttEchoPktDataRequestSize Integer32,
oacRttEchoPktDataResponseSize Integer32,
oacRttEchoTOS Integer32,
oacRttEchoProtocol OacRttProtocol
}
oacRttEchoSourceAddress OBJECT-TYPE
SYNTAX OacRttTargetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Source address to use when sending probes."
DEFVAL { "" }
::= { oacRttEchoEntry 1 }
oacRttEchoTargetAddress OBJECT-TYPE
SYNTAX OacRttTargetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the IP address of the target."
DEFVAL { "" }
::= { oacRttEchoEntry 2 }
oacRttEchoPktDataRequestSize OBJECT-TYPE
SYNTAX Integer32 (0..16384)
UNITS "octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the size of the packet to send."
DEFVAL { 1 }
::= { oacRttEchoEntry 3 }
oacRttEchoPktDataResponseSize OBJECT-TYPE
SYNTAX Integer32 (0..16384)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the size of the packet to receive."
DEFVAL { 0 }
::= { oacRttEchoEntry 4 }
oacRttEchoTOS OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object represents the type of service in an IP header."
DEFVAL { 0 }
::= { oacRttEchoEntry 5 }
oacRttEchoProtocol OBJECT-TYPE
SYNTAX OacRttProtocol
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Protocol type to use for the probes."
DEFVAL { notApplicable }
::= { oacRttEchoEntry 6 }
oacRttHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Definitions for history chcking for an RTT entry."
::= { oacRttControl 3 }
oacRttHistoryEntry OBJECT-TYPE
SYNTAX OacRttHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of definitions for hisotry collections."
AUGMENTS { oacRttControlEntry }
::= { oacRttHistoryTable 1 }
OacRttHistoryEntry ::= SEQUENCE
{
oacRttHistoryNumBuckets Integer32,
oacRttHistoryFilter INTEGER,
oacRttHistoryNumLives Integer32,
oacRttHistoryNumSamples Integer32
}
oacRttHistoryNumBuckets OBJECT-TYPE
SYNTAX Integer32 (1..60)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"MAximum buckets to record."
DEFVAL { 15 }
::= { oacRttHistoryEntry 1 }
oacRttHistoryFilter OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
all(2),
overThreshold(3),
failures(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Define filters for history recording."
DEFVAL { none }
::= { oacRttHistoryEntry 2 }
oacRttHistoryNumLives OBJECT-TYPE
SYNTAX Integer32 (0..2)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Define number of lives for history recording."
DEFVAL { 0 }
::= { oacRttHistoryEntry 3 }
oacRttHistoryNumSamples OBJECT-TYPE
SYNTAX Integer32 (1..30)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of samples to record for one bucket."
DEFVAL { 16 }
::= { oacRttHistoryEntry 4 }
oacRttSchedTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttSchedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Probe scheduling table."
::= { oacRttControl 4 }
oacRttSchedEntry OBJECT-TYPE
SYNTAX OacRttSchedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Probe scheduling entry in the scheduling table."
AUGMENTS { oacRttControlEntry }
::= { oacRttSchedTable 1 }
OacRttSchedEntry ::= SEQUENCE
{
oacRttSchedRttStartTime TimeTicks,
oacRttSchedRttLife Integer32,
oacRttSchedConceptRowAgeout Integer32
}
oacRttSchedRttStartTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies when to start the probe."
DEFVAL { 0 }
::= { oacRttSchedEntry 1 }
oacRttSchedRttLife OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies for how long the probe will remain active."
DEFVAL { 3600 }
::= { oacRttSchedEntry 2 }
oacRttSchedConceptRowAgeout OBJECT-TYPE
SYNTAX Integer32 (0..2073600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the age of created RTR session."
DEFVAL { 3600 }
::= { oacRttSchedEntry 3 }
oacRttReactTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttReactEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Probe reaction table."
::= { oacRttControl 5 }
oacRttReactEntry OBJECT-TYPE
SYNTAX OacRttReactEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Probe reaction entry in the table."
AUGMENTS { oacRttControlEntry }
::= { oacRttReactTable 1 }
OacRttReactEntry ::= SEQUENCE
{
oacRttReactActionType INTEGER,
oacRttReactThresholdType INTEGER,
oacRttReactThresholdCount Integer32,
oacRttReactThresholdCount2 Integer32,
oacRttReactConnectionEnable TruthValue,
oacRttReactVerifyErrorEnable TruthValue,
oacRttReactThresholdFalling Integer32,
oacRttReactTimeoutEnable TruthValue
}
oacRttReactActionType OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
trapOnly(2),
nmvtOnly(3),
triggerOnly(4),
trapAndNmvt(5),
trapAndTrigger(6),
nmvtAndTrigger(7),
trapNmvtAndTrigger(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the trigger as reaction."
DEFVAL { none }
::= { oacRttReactEntry 1 }
oacRttReactThresholdType OBJECT-TYPE
SYNTAX INTEGER
{
never(1),
immediate(2),
consecutive(3),
xOfy(4),
average(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the threshold type for reaction."
DEFVAL { never }
::= { oacRttReactEntry 2 }
oacRttReactThresholdCount OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the threshold count for reaction."
DEFVAL { 5 }
::= { oacRttReactEntry 3 }
oacRttReactThresholdCount2 OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the threshold count for reaction."
DEFVAL { 5 }
::= { oacRttReactEntry 4 }
oacRttReactConnectionEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies if the connection is enabled for reaction."
DEFVAL { false }
::= { oacRttReactEntry 5 }
oacRttReactVerifyErrorEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies if the error verification is enabled for reaction."
DEFVAL { false }
::= { oacRttReactEntry 6 }
oacRttReactThresholdFalling OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the threshold falling for reaction."
DEFVAL { 3000 }
::= { oacRttReactEntry 7 }
oacRttReactTimeoutEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies if the timeout is enabled for reaction."
DEFVAL { false }
::= { oacRttReactEntry 8 }
oacRttStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "RTT statistics table."
::= { oacRttControl 6 }
oacRttStatisticsEntry OBJECT-TYPE
SYNTAX OacRttStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "RTT statistics table entry."
AUGMENTS { oacRttControlEntry }
::= { oacRttStatisticsTable 1 }
OacRttStatisticsEntry ::= SEQUENCE
{
oacRttStatisticsNumDistBuckets Integer32,
oacRttStatisticsNumHops Integer32,
oacRttStatisticsNumPaths Integer32,
oacRttStatisticsDistInterval Integer32,
oacRttStatisticsNumHourGroups Integer32
}
oacRttStatisticsNumDistBuckets OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Number of distibution buckets."
DEFVAL { 1 }
::= { oacRttStatisticsEntry 1 }
oacRttStatisticsNumHops OBJECT-TYPE
SYNTAX Integer32 (1..30)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Number of hops."
DEFVAL { 16 }
::= { oacRttStatisticsEntry 2 }
oacRttStatisticsNumPaths OBJECT-TYPE
SYNTAX Integer32 (1..128)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Number of paths."
DEFVAL { 5 }
::= { oacRttStatisticsEntry 3 }
oacRttStatisticsDistInterval OBJECT-TYPE
SYNTAX Integer32 (1..100)
UNITS "milliseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Distribution interval."
DEFVAL { 20 }
::= { oacRttStatisticsEntry 4 }
oacRttStatisticsNumHourGroups OBJECT-TYPE
SYNTAX Integer32 (0..25)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Number of hour groups."
DEFVAL { 2 }
::= { oacRttStatisticsEntry 5 }
oacRttControlOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttControlOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table with values for a RTT entry."
::= { oacRttControl 7 }
oacRttControlOperEntry OBJECT-TYPE
SYNTAX OacRttControlOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "RTT entry."
AUGMENTS { oacRttControlEntry }
::= { oacRttControlOperTable 1 }
OacRttControlOperEntry ::= SEQUENCE
{
oacRttControlOperNumRtts Integer32,
oacRttControlOperOctetsInUse Gauge32,
oacRttControlOperDiagText DisplayString,
oacRttControlOperOverThresholdOccurred TruthValue,
oacRttControlOperState INTEGER,
oacRttControlOperTimeoutOccurred TruthValue,
oacRttControlOperRttLife Integer32,
oacRttControlOperModificationTime TimeStamp,
oacRttControlOperConnLostOccurred TruthValue,
oacRttControlOperResetTime TimeStamp
}
oacRttControlOperNumRtts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of probe total initialisation."
::= { oacRttControlOperEntry 1 }
oacRttControlOperOctetsInUse OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Octets in use by the entry."
::= { oacRttControlOperEntry 2 }
oacRttControlOperDiagText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..51))
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
DEFVAL { "" }
::= { oacRttControlOperEntry 3 }
oacRttControlOperOverThresholdOccurred OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies if threshold occured."
DEFVAL { false }
::= { oacRttControlOperEntry 4 }
oacRttControlOperState OBJECT-TYPE
SYNTAX INTEGER
{
reset(1),
orderlyStop(2),
immediateStop(3),
pending(4),
inactive(5),
active(6),
restart(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Operations state of the RTT entry."
::= { oacRttControlOperEntry 5 }
oacRttControlOperTimeoutOccurred OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "True if a timeout occured."
DEFVAL { false }
::= { oacRttControlOperEntry 6 }
oacRttControlOperRttLife OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value witch is decremented on every seconds.
When it reaches zero, the RTT entry is suspended."
::= { oacRttControlOperEntry 7 }
oacRttControlOperModificationTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { oacRttControlOperEntry 8 }
oacRttControlOperConnLostOccurred OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Connection loss occured."
DEFVAL { false }
::= { oacRttControlOperEntry 9 }
oacRttControlOperResetTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Reset time."
::= { oacRttControlOperEntry 10 }
oacRttReactTriggerTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttReactTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table witch defines witch entries became active
when a problem is detected."
::= { oacRttControl 8 }
oacRttReactTriggerEntry OBJECT-TYPE
SYNTAX OacRttReactTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Reaction trigger entry."
INDEX { oacRttControlIndex,
oacRttReactTriggerOacRttControlIndex }
::= { oacRttReactTriggerTable 1 }
OacRttReactTriggerEntry ::= SEQUENCE
{
oacRttReactTriggerOacRttControlIndex Integer32,
oacRttReactTriggerStatus RowStatus
}
oacRttReactTriggerOacRttControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Reaction trigger control index."
::= { oacRttReactTriggerEntry 1 }
oacRttReactTriggerStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to create a trigger."
DEFVAL { createAndGo }
::= { oacRttReactTriggerEntry 2 }
oacRttReactTriggerOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttReactTriggerOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Reaction trigger operation table."
::= { oacRttControl 9 }
oacRttReactTriggerOperEntry OBJECT-TYPE
SYNTAX OacRttReactTriggerOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Reaction trigger operation table entry."
AUGMENTS { oacRttReactTriggerEntry }
::= { oacRttReactTriggerOperTable 1 }
OacRttReactTriggerOperEntry ::= SEQUENCE
{
oacRttReactTriggerOperState INTEGER
}
oacRttReactTriggerOperState OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
pending(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Trigger state."
::= { oacRttReactTriggerOperEntry 1 }
oacRttLatestRttOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttLatestRttOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table with values for the latest RTT operation."
::= { oacRttControl 10 }
oacRttLatestRttOperEntry OBJECT-TYPE
SYNTAX OacRttLatestRttOperEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Operation entry."
AUGMENTS { oacRttControlEntry }
::= { oacRttLatestRttOperTable 1 }
OacRttLatestRttOperEntry ::= SEQUENCE
{
oacRttLatestRttOperTime TimeStamp,
oacRttLatestRttOperSense RttResponseSense,
oacRttLatestRttOperSenseDescription DisplayString,
oacRttLatestRttOperAddress OacRttTargetAddress,
oacRttLatestRttOperCompletionTime Gauge32,
oacRttLatestRttOperApplSpecificSense Integer32
}
oacRttLatestRttOperTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The system time when the latest operation occured."
::= { oacRttLatestRttOperEntry 1 }
oacRttLatestRttOperSense OBJECT-TYPE
SYNTAX RttResponseSense
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operation time."
::= { oacRttLatestRttOperEntry 2 }
oacRttLatestRttOperSenseDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operation sense description."
::= { oacRttLatestRttOperEntry 3 }
oacRttLatestRttOperAddress OBJECT-TYPE
SYNTAX OacRttTargetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The address of the target."
::= { oacRttLatestRttOperEntry 4 }
oacRttLatestRttOperCompletionTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operation completion time."
::= { oacRttLatestRttOperEntry 5 }
oacRttLatestRttOperApplSpecificSense OBJECT-TYPE
SYNTAX Integer32 (1001..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Operation application specific sense."
::= { oacRttLatestRttOperEntry 6 }
oacRttHistoryCollectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttHistoryCollectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The table with collected history information."
::= { oacRttHistory 1 }
oacRttHistoryCollectionEntry OBJECT-TYPE
SYNTAX OacRttHistoryCollectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "History collection entry."
INDEX { oacRttControlIndex,
oacRttHistoryCollectionLifeIndex,
oacRttHistoryCollectionBucketIndex,
oacRttHistoryCollectionSampleIndex
}
::= { oacRttHistoryCollectionTable 1 }
OacRttHistoryCollectionEntry ::= SEQUENCE
{
oacRttHistoryCollectionLifeIndex Integer32,
oacRttHistoryCollectionBucketIndex Integer32,
oacRttHistoryCollectionSampleIndex Integer32,
oacRttHistoryCollectionApplSpecificSense Integer32,
oacRttHistoryCollectionAddress OacRttTargetAddress,
oacRttHistoryCollectionSampleTime TimeStamp,
oacRttHistoryCollectionSense RttResponseSense,
oacRttHistoryCollectionSenseDescription DisplayString,
oacRttHistoryCollectionCompletionTime Gauge32
}
oacRttHistoryCollectionLifeIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "History collection life index."
::= { oacRttHistoryCollectionEntry 1 }
oacRttHistoryCollectionBucketIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "History collection bucket index."
::= { oacRttHistoryCollectionEntry 2 }
oacRttHistoryCollectionSampleIndex OBJECT-TYPE
SYNTAX Integer32 (1..512)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "History collection sample index."
::= { oacRttHistoryCollectionEntry 3 }
oacRttHistoryCollectionApplSpecificSense OBJECT-TYPE
SYNTAX Integer32 (1001..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "History collection application specific sense."
::= { oacRttHistoryCollectionEntry 4 }
oacRttHistoryCollectionAddress OBJECT-TYPE
SYNTAX OacRttTargetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "History collection address."
::= { oacRttHistoryCollectionEntry 5 }
oacRttHistoryCollectionSampleTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION "History collection sample time."
::= { oacRttHistoryCollectionEntry 6 }
oacRttHistoryCollectionSense OBJECT-TYPE
SYNTAX RttResponseSense
MAX-ACCESS read-only
STATUS current
DESCRIPTION "History collection sense."
::= { oacRttHistoryCollectionEntry 7 }
oacRttHistoryCollectionSenseDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "History collection sense description."
::= { oacRttHistoryCollectionEntry 8 }
oacRttHistoryCollectionCompletionTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "History collection completion time."
::= { oacRttHistoryCollectionEntry 9 }
oacRttStatsCollectTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttStatsCollectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table for collected statistical information."
::= { oacRttStats 1 }
oacRttStatsCollectEntry OBJECT-TYPE
SYNTAX OacRttStatsCollectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Statistics collection entry."
INDEX { oacRttControlIndex,
oacRttStatsCaptureStartTimeIndex,
oacRttStatsCapturePathIndex,
oacRttStatsCaptureHopIndex
}
::= { oacRttStatsCollectTable 1 }
OacRttStatsCollectEntry ::= SEQUENCE
{
oacRttStatsCollectAddress OacRttTargetAddress,
oacRttStatsCollectNoConnections Integer32,
oacRttStatsCollectBusies Integer32,
oacRttStatsCollectTimeouts Integer32,
oacRttStatsCollectSequenceErrors Integer32,
oacRttStatsCollectNumDisconnects Integer32,
oacRttStatsCollectVerifyErrors Integer32,
oacRttStatsCollectDrops Integer32
}
oacRttStatsCollectAddress OBJECT-TYPE
SYNTAX OacRttTargetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Collection address."
::= { oacRttStatsCollectEntry 1 }
oacRttStatsCollectNoConnections OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many times the connection cannot be etabilished."
::= { oacRttStatsCollectEntry 2 }
oacRttStatsCollectBusies OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many times the connection status was busy."
::= { oacRttStatsCollectEntry 3 }
oacRttStatsCollectTimeouts OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many timeouts."
::= { oacRttStatsCollectEntry 4 }
oacRttStatsCollectSequenceErrors OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many sequence errors."
::= { oacRttStatsCollectEntry 5 }
oacRttStatsCollectNumDisconnects OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many times the connection was disconnected."
::= { oacRttStatsCollectEntry 6 }
oacRttStatsCollectVerifyErrors OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many verify errors."
::= { oacRttStatsCollectEntry 7 }
oacRttStatsCollectDrops OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "How many drops."
::= { oacRttStatsCollectEntry 8 }
oacRttStatsCaptureTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttStatsCaptureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Statistics capture table."
::= { oacRttStats 2 }
oacRttStatsCaptureEntry OBJECT-TYPE
SYNTAX OacRttStatsCaptureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Statistics capture table entry."
INDEX { oacRttControlIndex,
oacRttStatsCaptureStartTimeIndex,
oacRttStatsCapturePathIndex,
oacRttStatsCaptureHopIndex,
oacRttStatsCaptureDistIndex
}
::= { oacRttStatsCaptureTable 1 }
OacRttStatsCaptureEntry ::= SEQUENCE
{
oacRttStatsCaptureStartTimeIndex TimeStamp,
oacRttStatsCapturePathIndex Integer32,
oacRttStatsCaptureHopIndex Integer32,
oacRttStatsCaptureDistIndex Integer32,
oacRttStatsCaptureSumCompletionTime Gauge32,
oacRttStatsCaptureSumCompletionTime2Low Gauge32,
oacRttStatsCaptureSumCompletionTime2High Gauge32,
oacRttStatsCaptureCompletionTimeMin Gauge32,
oacRttStatsCaptureCompletionTimeMax Gauge32,
oacRttStatsCaptureOverThresholds Integer32,
oacRttStatsCaptureCompletions Integer32
}
oacRttStatsCaptureStartTimeIndex OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Capture start time index."
::= { oacRttStatsCaptureEntry 1 }
oacRttStatsCapturePathIndex OBJECT-TYPE
SYNTAX Integer32 (1..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Capture path index."
::= { oacRttStatsCaptureEntry 2 }
oacRttStatsCaptureHopIndex OBJECT-TYPE
SYNTAX Integer32 (1..30)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Capture hop index."
::= { oacRttStatsCaptureEntry 3 }
oacRttStatsCaptureDistIndex OBJECT-TYPE
SYNTAX Integer32 (1..20)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies buckets for a hop."
::= { oacRttStatsCaptureEntry 4 }
oacRttStatsCaptureSumCompletionTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Capture sum completion time."
::= { oacRttStatsCaptureEntry 5 }
oacRttStatsCaptureSumCompletionTime2Low OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Low part of the accumulated squares of completion times."
::= { oacRttStatsCaptureEntry 6 }
oacRttStatsCaptureSumCompletionTime2High OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "High part of the accumulated squares of completion times."
::= { oacRttStatsCaptureEntry 7 }
oacRttStatsCaptureCompletionTimeMin OBJECT-TYPE
SYNTAX Gauge32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Minimum completion time."
::= { oacRttStatsCaptureEntry 8 }
oacRttStatsCaptureCompletionTimeMax OBJECT-TYPE
SYNTAX Gauge32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum completion time."
::= { oacRttStatsCaptureEntry 9 }
oacRttStatsCaptureOverThresholds OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Capture over tresholds."
::= { oacRttStatsCaptureEntry 10 }
oacRttStatsCaptureCompletions OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of completed RTT probes."
::= { oacRttStatsCaptureEntry 11 }
oacRttStatsTotalsTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttStatsTotalsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Totals table."
::= { oacRttStats 3 }
oacRttStatsTotalsEntry OBJECT-TYPE
SYNTAX OacRttStatsTotalsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Totals table entry."
INDEX { oacRttControlIndex,
oacRttStatsCaptureStartTimeIndex
}
::= { oacRttStatsTotalsTable 1 }
OacRttStatsTotalsEntry ::= SEQUENCE
{
oacRttStatsTotalsInitiations Integer32,
oacRttStatsTotalsElapsedTime TimeInterval
}
oacRttStatsTotalsInitiations OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Totals initiations."
::= { oacRttStatsTotalsEntry 1 }
oacRttStatsTotalsElapsedTime OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Totals elapsed time."
::= { oacRttStatsTotalsEntry 2 }
-- bodhi's jitter table
oacRttStatsJitterHopTable OBJECT-TYPE
SYNTAX SEQUENCE OF OacRttStatsJitterHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Jitter HOP table."
::= { oacRttStats 4 }
oacRttStatsJitterHopEntry OBJECT-TYPE
SYNTAX OacRttStatsJitterHopEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Jitter HOP table entry."
INDEX { oacRttControlIndex,
oacRttStatsJitterPathIndex,
oacRttStatsJitterHopIndex
}
::= { oacRttStatsJitterHopTable 1 }
OacRttStatsJitterHopEntry ::= SEQUENCE
{
oacRttStatsJitterPathIndex Integer32,
oacRttStatsJitterHopIndex Integer32,
oacRttStatsJitterHopIpAddress InetAddress,
oacRttStatsJitterHopRTT Integer32,
oacRttStatsJitterHopPacketLoss Integer32,
oacRttStatsJitterHopJitter Integer32,
oacRttStatsJitterHopMinRTT Integer32,
oacRttStatsJitterHopMaxRTT Integer32,
oacRttStatsJitterHopSumRTT Integer32,
oacRttStatsJitterHopSum2RTT Integer32,
oacRttStatsJitterHopMinPosJitter Integer32,
oacRttStatsJitterHopMaxPosJitter Integer32,
oacRttStatsJitterHopSumPos Integer32,
oacRttStatsJitterHopSum2Pos Integer32,
oacRttStatsJitterHopMinNegJitter Integer32,
oacRttStatsJitterHopMaxNegJitter Integer32,
oacRttStatsJitterHopSumNeg Integer32,
oacRttStatsJitterHopSum2Neg Integer32,
oacRttStatsJitterHopOutOfSequence Integer32,
oacRttStatsJitterHopDiscardedSamples Integer32
}
oacRttStatsJitterPathIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies a RTT row in oacRttStatsJitterHopTable along with oacRttStatsJitterHopIndex."
::= { oacRttStatsJitterHopEntry 1 }
oacRttStatsJitterHopIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies a RTT row in oacRttStatsJitterHopTable along with oacRttStatsJitterPathIndex."
::= { oacRttStatsJitterHopEntry 2 }
oacRttStatsJitterHopIpAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "IP Address of the Hop."
::= { oacRttStatsJitterHopEntry 3 }
oacRttStatsJitterHopRTT OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RTT for the Hop."
::= { oacRttStatsJitterHopEntry 4 }
oacRttStatsJitterHopPacketLoss OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Packet loss for the Hop."
::= { oacRttStatsJitterHopEntry 5 }
oacRttStatsJitterHopJitter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Jitter for the Hop."
::= { oacRttStatsJitterHopEntry 6 }
oacRttStatsJitterHopMinRTT OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Min RTT for the Hop."
::= { oacRttStatsJitterHopEntry 7 }
oacRttStatsJitterHopMaxRTT OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Max RTT for the Hop."
::= { oacRttStatsJitterHopEntry 8 }
oacRttStatsJitterHopSumRTT OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sum RTT for the Hop."
::= { oacRttStatsJitterHopEntry 9 }
oacRttStatsJitterHopSum2RTT OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sum2 RTT for the Hop."
::= { oacRttStatsJitterHopEntry 10 }
oacRttStatsJitterHopMinPosJitter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Min pos jitter for the Hop."
::= { oacRttStatsJitterHopEntry 11 }
oacRttStatsJitterHopMaxPosJitter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Max pos jitter for the Hop."
::= { oacRttStatsJitterHopEntry 12 }
oacRttStatsJitterHopSumPos OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sum pos jitter for the Hop."
::= { oacRttStatsJitterHopEntry 13 }
oacRttStatsJitterHopSum2Pos OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sum2 pos jitter for the Hop."
::= { oacRttStatsJitterHopEntry 14 }
oacRttStatsJitterHopMinNegJitter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Min neg jitter for the Hop."
::= { oacRttStatsJitterHopEntry 15 }
oacRttStatsJitterHopMaxNegJitter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Max neg jitter for the Hop."
::= { oacRttStatsJitterHopEntry 16 }
oacRttStatsJitterHopSumNeg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sum neg jitter for the Hop."
::= { oacRttStatsJitterHopEntry 17 }
oacRttStatsJitterHopSum2Neg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sum2 neg jitter for the Hop."
::= { oacRttStatsJitterHopEntry 18 }
oacRttStatsJitterHopOutOfSequence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Out of sequence pkts for the Hop."
::= { oacRttStatsJitterHopEntry 19 }
oacRttStatsJitterHopDiscardedSamples OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Discarded samples for the Hop."
::= { oacRttStatsJitterHopEntry 20 }
-- endof bodhi's jitter table
oacRttNotificationsPrefix OBJECT IDENTIFIER
::= { oacRttChkMIB 2 }
oacRttNotifications OBJECT IDENTIFIER
::= { oacRttNotificationsPrefix 0 }
oacRttConnectionChangeNotification NOTIFICATION-TYPE
OBJECTS { oacRttControlTag,
oacRttHistoryCollectionAddress,
oacRttControlOperConnLostOccurred
}
STATUS current
DESCRIPTION
""
::= { oacRttNotifications 1 }
oacRttTimeoutNotification NOTIFICATION-TYPE
OBJECTS { oacRttControlTag,
oacRttHistoryCollectionAddress,
oacRttControlOperTimeoutOccurred
}
STATUS current
DESCRIPTION ""
::= { oacRttNotifications 2 }
oacRttThresholdNotification NOTIFICATION-TYPE
OBJECTS { oacRttControlTag,
oacRttHistoryCollectionAddress,
oacRttControlOperOverThresholdOccurred
}
STATUS current
DESCRIPTION ""
::= { oacRttNotifications 3 }
END