547 lines
21 KiB
Plaintext
547 lines
21 KiB
Plaintext
TIMETRA-SAS-ALARM-INPUT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-COMPLIANCE, NOTIFICATION-GROUP,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
Integer32, MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE, OBJECT-TYPE,
|
|
TimeTicks
|
|
FROM SNMPv2-SMI
|
|
tmnxChassisNotifyHwIndex, tmnxHwClass,
|
|
tmnxHwID
|
|
FROM TIMETRA-CHASSIS-MIB
|
|
tmnxBasedProducts
|
|
FROM TIMETRA-GLOBAL-MIB
|
|
TItemLongDescription
|
|
FROM TIMETRA-TC-MIB
|
|
;
|
|
|
|
tmnxSasAlarmInputMIBModule MODULE-IDENTITY
|
|
LAST-UPDATED "201507080000Z"
|
|
ORGANIZATION "Nokia"
|
|
CONTACT-INFO
|
|
"Nokia 7x50 Support
|
|
Web: http://www.nokia.com"
|
|
DESCRIPTION
|
|
"This document is the SNMP MIB module for the Nokia SROS implementation
|
|
of Alarm Contact Inputs.
|
|
|
|
Copyright 2003-2018 Nokia. All rights reserved. Reproduction of this
|
|
document is authorized on the condition that the foregoing copyright
|
|
notice is included.
|
|
|
|
This SNMP MIB module (Specification) embodies Nokia's proprietary
|
|
intellectual property. Nokia retains all title and ownership in the
|
|
Specification, including any revisions.
|
|
|
|
Nokia grants all interested parties a non-exclusive license
|
|
to use and distribute an unmodified copy of this Specification
|
|
in connection with management of Nokia products, and without
|
|
fee, provided this copyright notice and license appear on all
|
|
copies.
|
|
|
|
This Specification is supplied `as is', and Nokia makes no
|
|
warranty, either express or implied, as to the use, operation,
|
|
condition, or performance of the Specification."
|
|
|
|
REVISION "201507080000Z"
|
|
DESCRIPTION
|
|
"Rev 2.0 08 Jul 2015 00:00
|
|
2.0 release of the TIMETRA-SAS-ALARM-INPUT-MIB."
|
|
|
|
REVISION "201004080000Z"
|
|
DESCRIPTION
|
|
"Rev 2.0 08 Apr 2010 00:00
|
|
2.0 release of the TIMETRA-SAS-ALARM-INPUT-MIB."
|
|
|
|
::= { timetraSASModules 10 }
|
|
|
|
timetraServiceAccessSwitches OBJECT IDENTIFIER ::= { tmnxBasedProducts 2 }
|
|
|
|
timetraSASRegistry OBJECT IDENTIFIER ::= { timetraServiceAccessSwitches 1 }
|
|
|
|
timetraSASModules OBJECT IDENTIFIER ::= { timetraSASRegistry 1 }
|
|
|
|
timetraSASMIB OBJECT IDENTIFIER ::= { timetraServiceAccessSwitches 2 }
|
|
|
|
timetraSASConfs OBJECT IDENTIFIER ::= { timetraSASMIB 1 }
|
|
|
|
tmnxSASAlarmInputConformance OBJECT IDENTIFIER ::= { timetraSASConfs 6 }
|
|
|
|
tmnxSASAlarmInputCompliances OBJECT IDENTIFIER ::= { tmnxSASAlarmInputConformance 1 }
|
|
|
|
tmnxSASAlarmInputComp7210V2v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSASAlarmInputComp7210V2v0 identifies compliance
|
|
statement for external equipment alarm inputs in Nokia 7210 series
|
|
system, release 2.0."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxSASAlarmInputV2v0Group,
|
|
tmnxAlmInpV2v0NotifyObjsGroup,
|
|
tmnxAlarmInputNotificationV2v0Group
|
|
}
|
|
::= { tmnxSASAlarmInputCompliances 1 }
|
|
|
|
tmnxSASAlarmInputComp7X50V13v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSASAlarmInputComp7X50V13v0 identifies compliance
|
|
statement for external equipment alarm inputs in Nokia 7X50 series
|
|
system, release 13.0."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxAlInpV13v0NotificationGroup
|
|
}
|
|
::= { tmnxSASAlarmInputCompliances 2 }
|
|
|
|
tmnxSASAlarmInputGroups OBJECT IDENTIFIER ::= { tmnxSASAlarmInputConformance 2 }
|
|
|
|
tmnxSASAlarmInputV2v0Group OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxSasAlarmInputDescription,
|
|
tmnxSasAlarmInputAdminState,
|
|
tmnxSasAlarmInputPolarity,
|
|
tmnxSasAlarmOutputSeverity,
|
|
tmnxSasAlarmInputStatus,
|
|
tmnxSasAlarmInputLastChange,
|
|
tmnxSasAlarmInputTriggerMessage,
|
|
tmnxSasAlarmInputClearMessage,
|
|
tmnxSasAlarmInputPowerStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting the alarm input configuration on Nokia
|
|
7210 Release 2.0."
|
|
::= { tmnxSASAlarmInputGroups 1 }
|
|
|
|
tmnxAlarmInputNotificationV2v0Group NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxSasAlarminput1StateChanged,
|
|
tmnxSasAlarminput2StateChanged,
|
|
tmnxSasAlarminput3StateChanged,
|
|
tmnxSasAlarminput4StateChanged
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of notifications supporting the the alarm input capabilities
|
|
on Nokia 7210 Release 2.0."
|
|
::= { tmnxSASAlarmInputGroups 2 }
|
|
|
|
tmnxAlmInpV2v0NotifyObjsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxSasAlarmInputNotifyId,
|
|
tmnxSasAlarmInputNotifyMessage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of notification objects supporting the the alarm input
|
|
capabilities on Nokia 7210 Release 2.0."
|
|
::= { tmnxSASAlarmInputGroups 3 }
|
|
|
|
tmnxAlInpV13v0NotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxAlarmInputVoltageFailure
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting the alarm input configuration on Nokia
|
|
7X50 Release 13.0."
|
|
::= { tmnxSASAlarmInputGroups 5 }
|
|
|
|
timetraSASObjs OBJECT IDENTIFIER ::= { timetraSASMIB 2 }
|
|
|
|
tmnxSASChassisObjs OBJECT IDENTIFIER ::= { timetraSASObjs 6 }
|
|
|
|
tmnxSASChassisNotification OBJECT IDENTIFIER ::= { tmnxSASChassisObjs 2 }
|
|
|
|
tmnxAlarmInputVoltageFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxSasAlarmInputPowerStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] A tmnxAlarmInputVoltageFailure notification is sent when the
|
|
internal power supply for alarm inputs fails. The value of
|
|
tmnxSasAlarmInputPowerStatus indicates whether the power to external
|
|
alarm inputs is on or off.
|
|
|
|
[EFFECT] If the alarm inputs use the internal power supply, then a
|
|
failure in the power supply will cause state change event
|
|
alarms to not be raised.
|
|
|
|
[RECOVERY] Check the internal power source for alarm inputs and
|
|
rectify the problem."
|
|
::= { tmnxSASChassisNotification 10 }
|
|
|
|
tmnxSasAlarmInputObjs OBJECT IDENTIFIER ::= { timetraSASObjs 9 }
|
|
|
|
tmnxSasAlarmInputInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxSasAlarmInputInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table tmnxSasAlarmInputInfoTable contains alarm input
|
|
configuration.
|
|
|
|
This table contains information about alarm inputs driven by external
|
|
equipment."
|
|
::= { tmnxSasAlarmInputObjs 1 }
|
|
|
|
tmnxSasAlarmInputInfoEntry OBJECT-TYPE
|
|
SYNTAX TmnxSasAlarmInputInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry tmnxSasAlarmInputInfoEntry represents one alarm input
|
|
contact.
|
|
|
|
Rows in this table are created at startup by SROS. Rows in this table
|
|
are never destroyed."
|
|
INDEX { tmnxSasAlarmInputId }
|
|
::= { tmnxSasAlarmInputInfoTable 1 }
|
|
|
|
TmnxSasAlarmInputInfoEntry ::= SEQUENCE
|
|
{
|
|
tmnxSasAlarmInputId Integer32,
|
|
tmnxSasAlarmInputDescription TItemLongDescription,
|
|
tmnxSasAlarmInputAdminState INTEGER,
|
|
tmnxSasAlarmInputPolarity INTEGER,
|
|
tmnxSasAlarmOutputSeverity INTEGER,
|
|
tmnxSasAlarmInputStatus INTEGER,
|
|
tmnxSasAlarmInputLastChange TimeTicks
|
|
}
|
|
|
|
tmnxSasAlarmInputId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputId specifies the alarm contact
|
|
identifier."
|
|
::= { tmnxSasAlarmInputInfoEntry 1 }
|
|
|
|
tmnxSasAlarmInputDescription OBJECT-TYPE
|
|
SYNTAX TItemLongDescription (SIZE (0..160))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputDescription specifies the description of
|
|
this alarm input entry."
|
|
DEFVAL { "" }
|
|
::= { tmnxSasAlarmInputInfoEntry 2 }
|
|
|
|
tmnxSasAlarmInputAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up (1),
|
|
down (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputAdminState specifies the administrative
|
|
state of the alarm input.
|
|
|
|
Values:
|
|
up (1) - Specifies that a given alarm-input is operational.
|
|
down (2) - Specifies that a given alarm-input is not operational."
|
|
DEFVAL { down }
|
|
::= { tmnxSasAlarmInputInfoEntry 3 }
|
|
|
|
tmnxSasAlarmInputPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyOpen (1),
|
|
normallyClosed (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputPolarity specifies the polarity of the
|
|
alarm input circuit. This value specifies if the state of alram input
|
|
when it is in normal operation (i.e. when there is no alarm).
|
|
|
|
Values:
|
|
normallyOpen (1) - Specifies that a given alarm-input is open
|
|
when normal.
|
|
normallyClosed (2) - Specifies that a given alarm-input is closed
|
|
when normal."
|
|
DEFVAL { normallyOpen }
|
|
::= { tmnxSasAlarmInputInfoEntry 4 }
|
|
|
|
tmnxSasAlarmOutputSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
minor (2),
|
|
major (3),
|
|
critical (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmOutputSeverity specifies the configured
|
|
output severity of the alarm.
|
|
|
|
Values:
|
|
none (1) - Specifies that severity of the alarm is none.
|
|
minor (2) - Specifies that severity of the alarm is minor.
|
|
major (3) - Specifies that severity of the alarm is major.
|
|
critical (4) - Specifies that severity of the alarm is critical."
|
|
DEFVAL { major }
|
|
::= { tmnxSasAlarmInputInfoEntry 5 }
|
|
|
|
tmnxSasAlarmInputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAlarm (1),
|
|
alarm (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputStatus indicates the current status of
|
|
the alarm.
|
|
|
|
Values:
|
|
noAlarm (1) - Indicates that there was no alarm raised.
|
|
alarm (2) - Indicates that there was an alarm raised."
|
|
::= { tmnxSasAlarmInputInfoEntry 6 }
|
|
|
|
tmnxSasAlarmInputLastChange OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputLastChange indicates the value of
|
|
sysUpTime at the time of the last configuration change an object in
|
|
the specified row."
|
|
::= { tmnxSasAlarmInputInfoEntry 7 }
|
|
|
|
tmnxSasAlarmInputMessageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxSasAlarmInputMessageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table tmnxSasAlarmInputMessageTable contains user defined messages
|
|
that are configured to be sent out with notifications.
|
|
|
|
This table contains information about the messages that have been
|
|
configured to be sent out in the alarm for each alarm input. This
|
|
table permits the trigger message and clear message to be defined
|
|
independently."
|
|
::= { tmnxSasAlarmInputObjs 2 }
|
|
|
|
tmnxSasAlarmInputMessageEntry OBJECT-TYPE
|
|
SYNTAX TmnxSasAlarmInputMessageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputMessageEntry represents one alarm input
|
|
contact.
|
|
|
|
Rows in the table tmnxSasAlarmInputMessageTable are created at SROS
|
|
startup and are never destroyed."
|
|
INDEX { tmnxSasAlarmInputId }
|
|
::= { tmnxSasAlarmInputMessageTable 1 }
|
|
|
|
TmnxSasAlarmInputMessageEntry ::= SEQUENCE
|
|
{
|
|
tmnxSasAlarmInputTriggerMessage OCTET STRING,
|
|
tmnxSasAlarmInputClearMessage OCTET STRING
|
|
}
|
|
|
|
tmnxSasAlarmInputTriggerMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputTriggerMessage specifies the user
|
|
defined alarm trigger event description, for a given alarm input, to
|
|
be sent out to NMS in a SNMP trap when the alarm triggers."
|
|
DEFVAL { "" }
|
|
::= { tmnxSasAlarmInputMessageEntry 1 }
|
|
|
|
tmnxSasAlarmInputClearMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputClearMessage specifies the user defined
|
|
alarm clear event description, for a given alarm input, to be sent out
|
|
to NMS in a SNMP trap when the alarm clears."
|
|
DEFVAL { "" }
|
|
::= { tmnxSasAlarmInputMessageEntry 2 }
|
|
|
|
tmnxSasAlarmInputPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (0),
|
|
on (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value of tmnxSasAlarmInputPowerStatus specifies the configuration
|
|
to turn the power on or off, to all the external alarm input devices.
|
|
|
|
Values:
|
|
off (0) - Turns off the output power supply to all alarm-inputs.
|
|
on (1) - Turns on the output power supply to all alarm-inputs."
|
|
DEFVAL { off }
|
|
::= { tmnxSasAlarmInputObjs 3 }
|
|
|
|
tmnxSasAlarmInputNotifyObjs OBJECT IDENTIFIER ::= { timetraSASObjs 10 }
|
|
|
|
tmnxSasAlarmInputNotifyId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputNotifyId indicates the identifier of
|
|
alarm input contact associated with the notification."
|
|
::= { tmnxSasAlarmInputNotifyObjs 1 }
|
|
|
|
tmnxSasAlarmInputNotifyMessage OBJECT-TYPE
|
|
SYNTAX TItemLongDescription (SIZE (0..160))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSasAlarmInputNotifyMessage indicates the message to
|
|
be sent out with the alarm input state changed event.
|
|
tmnxSasAlarmInputNotifyMessage message is composed using
|
|
tmnxSasAlarmInputTriggerMessage or tmnxSasAlarmInputTriggerMessage."
|
|
::= { tmnxSasAlarmInputNotifyObjs 2 }
|
|
|
|
timetraSASNotifyPrefix OBJECT IDENTIFIER ::= { timetraSASMIB 3 }
|
|
|
|
tmnxSasAlarmInputNotifications OBJECT IDENTIFIER ::= { timetraSASNotifyPrefix 10 }
|
|
|
|
tmnxSasAlarminput1StateChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxSasAlarmInputNotifyId,
|
|
tmnxSasAlarmInputDescription,
|
|
tmnxSasAlarmInputStatus,
|
|
tmnxSasAlarmOutputSeverity,
|
|
tmnxSasAlarmInputNotifyMessage,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] A tmnxSasAlarminput1StateChanged notification is sent when
|
|
status of the alarm input on pin one(1) changes.
|
|
|
|
|
|
When this notification is sent, the field
|
|
tmnxSasAlarmInputNotifyMessage is populated with either the
|
|
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
|
|
tmnxSasAlarmInputClearMessage when the alarm is cleared.
|
|
|
|
The trigger or clear actions depend on the polarity of the input as
|
|
defined in tmnxSasAlarmInputPolarity.
|
|
|
|
[EFFECT] A desirable or undesirable event has occurred in the external
|
|
equipment connected to the alarm input. Hence the characteristics of
|
|
effect and the associated risks vary depending on the nature of the
|
|
external equipment being monitored over the alarm input.
|
|
|
|
[RECOVERY] Check the external equipment, connected to the alarm input
|
|
pin one(1), that resulted in this alarm and rectify the problem."
|
|
::= { tmnxSasAlarmInputNotifications 1 }
|
|
|
|
tmnxSasAlarminput2StateChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxSasAlarmInputNotifyId,
|
|
tmnxSasAlarmInputDescription,
|
|
tmnxSasAlarmInputStatus,
|
|
tmnxSasAlarmOutputSeverity,
|
|
tmnxSasAlarmInputNotifyMessage,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] A tmnxSasAlarminput2StateChanged notification is sent when
|
|
status of the alarm input on pin two(2) changes.
|
|
|
|
When this notification is sent, the field
|
|
tmnxSasAlarmInputNotifyMessage is populated with either the
|
|
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
|
|
tmnxSasAlarmInputClearMessage when the alarm is cleared.
|
|
|
|
The trigger or clear actions depend on the polarity of the input as
|
|
defined in tmnxSasAlarmInputPolarity.
|
|
|
|
[EFFECT] A desirable or undesirable event has occurred in the external
|
|
equipment connected to the alarm input. Hence the characteristics of
|
|
effect and the associated risks vary depending on the nature of the
|
|
external equipment being monitored over the alarm input.
|
|
|
|
[RECOVERY] Check the external equipment, connected to the alarm input
|
|
pin two(2), that resulted in this alarm and rectify the problem."
|
|
::= { tmnxSasAlarmInputNotifications 2 }
|
|
|
|
tmnxSasAlarminput3StateChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxSasAlarmInputNotifyId,
|
|
tmnxSasAlarmInputDescription,
|
|
tmnxSasAlarmInputStatus,
|
|
tmnxSasAlarmOutputSeverity,
|
|
tmnxSasAlarmInputNotifyMessage,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] A tmnxSasAlarminput3StateChanged notification is sent when
|
|
status of the alarm input on pin three(3) changes.
|
|
|
|
When this notification is sent, the field
|
|
tmnxSasAlarmInputNotifyMessage is populated with either the
|
|
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
|
|
tmnxSasAlarmInputClearMessage when the alarm is cleared.
|
|
|
|
The trigger or clear actions depend on the polarity of the input as
|
|
defined in tmnxSasAlarmInputPolarity.
|
|
|
|
[EFFECT] A desirable or undesirable event has occurred in the external
|
|
equipment connected to the alarm input. Hence the characteristics of
|
|
effect and the associated risks vary depending on the nature of the
|
|
external equipment being monitored over the alarm input.
|
|
|
|
[RECOVERY] Check the external equipment, connected to the alarm input
|
|
pin three(3), that resulted in this alarm and rectify the problem."
|
|
::= { tmnxSasAlarmInputNotifications 3 }
|
|
|
|
tmnxSasAlarminput4StateChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxSasAlarmInputNotifyId,
|
|
tmnxSasAlarmInputDescription,
|
|
tmnxSasAlarmInputStatus,
|
|
tmnxSasAlarmOutputSeverity,
|
|
tmnxSasAlarmInputNotifyMessage,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] A tmnxSasAlarminput4StateChanged notification is sent when
|
|
status of the alarm input on pin four(4) changes.
|
|
|
|
When this notification is sent, the field
|
|
tmnxSasAlarmInputNotifyMessage is populated with either the
|
|
tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the
|
|
tmnxSasAlarmInputClearMessage when the alarm is cleared.
|
|
|
|
The trigger or clear actions depend on the polarity of the input as
|
|
defined in tmnxSasAlarmInputPolarity.
|
|
|
|
[EFFECT] A desirable or undesirable event has occurred in the external
|
|
equipment connected to the alarm input. Hence the characteristics of
|
|
effect and the associated risks vary depending on the nature of the
|
|
external equipment being monitored over the alarm input.
|
|
|
|
[RECOVERY] Check the external equipment, connected to the alarm input
|
|
pin four(4), that resulted in this alarm and rectify the problem."
|
|
::= { tmnxSasAlarmInputNotifications 4 }
|
|
|
|
END
|