Observium_CE/mibs/nokia/TIMETRA-IEEE8021-CFM-MIB

6046 lines
231 KiB
Plaintext

TIMETRA-IEEE8021-CFM-MIB DEFINITIONS ::= BEGIN
IMPORTS
Dot1agCfmInterfaceStatus,
Dot1agCfmLowestAlarmPri,
Dot1agCfmMDLevel,
Dot1agCfmMaintAssocName,
Dot1agCfmMaintDomainNameType,
Dot1agCfmMepId, Dot1agCfmMepIdOrZero,
Dot1agCfmMpDirection,
Dot1agCfmPortStatus, VlanId,
VlanIdOrNone, dot1agCfmDefaultMdEntry,
dot1agCfmMaCompEntry, dot1agCfmMaIndex,
dot1agCfmMaMepListEntry,
dot1agCfmMaNetEntry, dot1agCfmMdEntry,
dot1agCfmMdIndex, dot1agCfmMepDbEntry,
dot1agCfmMepEntry,
dot1agCfmMepIdentifier,
dot1agCfmMepTransmitLbmDestMacAddress,
dot1agCfmMepTransmitLtmSeqNumber
FROM IEEE8021-CFM-MIB
InterfaceIndex, InterfaceIndexOrZero
FROM IF-MIB
LldpChassisIdSubtype
FROM LLDP-MIB
MODULE-COMPLIANCE, NOTIFICATION-GROUP,
OBJECT-GROUP
FROM SNMPv2-CONF
Counter32, Gauge32, Integer32,
MODULE-IDENTITY, NOTIFICATION-TYPE,
OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
DateAndTime, DisplayString, MacAddress,
RowStatus, TEXTUAL-CONVENTION,
TimeInterval, TruthValue
FROM SNMPv2-TC
timetraSRMIBModules, tmnxSRConfs,
tmnxSRNotifyPrefix, tmnxSRObjs
FROM TIMETRA-GLOBAL-MIB
SdpId
FROM TIMETRA-SERV-MIB
TFCSet, TItemDescription, TLNamedItem,
TLNamedItemOrEmpty, TNamedItem,
TmnxCreateOrigin, TmnxEnabledDisabled,
TmnxServId
FROM TIMETRA-TC-MIB
;
timetraIEEE8021CfmMIBModule MODULE-IDENTITY
LAST-UPDATED "201603110000Z"
ORGANIZATION "Nokia"
CONTACT-INFO
"Nokia SROS Support
Web: http://www.nokia.com"
DESCRIPTION
"This document is the SNMP MIB module to manage and provision dot1ag
Connectivity Fault Management module functionality for the Nokia SROS
products. This includes extensions to the IEEE8021-CFM MIB.
Copyright 2008-2018 Nokia. All rights reserved. Reproduction of this
document is authorized on the condition that the foregoing copyright
notice is included.
This SNMP MIB module (Specification) embodies Nokia's
proprietary intellectual property. Nokia retains
all title and ownership in the Specification, including any
revisions.
Nokia grants all interested parties a non-exclusive license to use and
distribute an unmodified copy of this Specification in connection with
management of Nokia products, and without fee, provided this copyright
notice and license appear on all copies.
This Specification is supplied 'as is', and Nokia makes no warranty,
either express or implied, as to the use, operation, condition, or
performance of the Specification."
REVISION "201603110000Z"
DESCRIPTION
"Rev 15.0 11 Mar 2016 00:00
15.0 release of the TIMETRA-IEEE8021-CFM-MIB."
REVISION "201601010000Z"
DESCRIPTION
"Rev 14.0 1 Jan 2016 00:00
14.0 release of the TIMETRA-IEEE8021-CFM-MIB."
REVISION "201501010000Z"
DESCRIPTION
"Rev 13.0 1 Jan 2015 00:00
13.0 release of the TIMETRA-IEEE8021-CFM-MIB."
REVISION "201401010000Z"
DESCRIPTION
"Rev 12.0 1 Jan 2014 00:00
12.0 release of the TIMETRA-IEEE8021-CFM-MIB."
REVISION "201102010000Z"
DESCRIPTION
"Rev 9.0 1 Feb 2011 00:00
9.0 release of the TIMETRA-IEEE8021-CFM-MIB."
REVISION "200902280000Z"
DESCRIPTION
"Rev 7.0 28 Feb 2009 00:00
7.0 release of the TIMETRA-IEEE8021-CFM-MIB."
REVISION "200801010000Z"
DESCRIPTION
"Rev 1.0 01 Jan 2008 00:00
Initial version of the TIMETRA-IEEE8021-CFM-MIB."
::= { timetraSRMIBModules 52 }
Dot1agCfmStatisticOpcodeName ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value indicating the CFM PDU Opcode to which a statistic
may be associated.
other(1) Indicates the CFM PDU type does not match
any other type explicitly detailed below.
ccm(2) Connectivity check messages.
lbr(3) Loopback response messages.
lbm(4) Loopback request messages.
ltr(5) Linktrace response messages.
ltm(6) Linktrace request messages.
ais(7) Alarm indication signal messages.
lck(8) Ethernet locked signal messages.
tst(9) Ethernet test signal messages.
laps(10) Linear automatic protection switching messages.
raps(11) Ring automatic protection switching messages.
mcc(12) Maintenance communications channel messages.
lmr(13) Ethernet loss measurement response messages.
lmm(14) Ethernet loss measurement messages.
odm(15) One way delay measurement messages.
dmr(16) Delay measurement response messages.
dmm(17) Delay measurement message.
exr(18) Ethernet experimental response messages.
exm(19) Ethernet experimental messages.
csf(20) Client signal fail messages.
vsr(21) Vendor specific response messages.
vsm(22) Vendor specific messages.
osl(23) One way synthetic loss measurement messages.
slr(24) Synthetic loss measurement response messages.
slm(25) Synthetic loss measurement messages.
gnm(26) Generic notification messages."
REFERENCE
"Y.1731 clauses 7 and 8"
SYNTAX INTEGER {
other (1),
ccm (2),
lbr (3),
lbm (4),
ltr (5),
ltm (6),
ais (7),
lck (8),
tst (9),
laps (10),
raps (11),
mcc (12),
lmr (13),
lmm (14),
odm (15),
dmr (16),
dmm (17),
exr (18),
exm (19),
csf (20),
vsr (21),
vsm (22),
osl (23),
slr (24),
slm (25),
gnm (26)
}
TmnxDot1agCfmMepFclty ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"TmnxDot1agCfmMepFclty is an enumerated integer that indicates the
facility type that a facility MEP has affected.
value indicates
-----------------------------------
port(1) physical port
lag (2) lag port
networkInterface(3) network interface
qinqPortTunnelSap(4) QinQ on physical port
qinqLagTunnelSap(5) QinQ on lag port"
SYNTAX INTEGER {
port (1),
lag (2),
networkInterface (3),
qinqPortTunnelSap (4),
qinqLagTunnelSap (5)
}
TmnxDot1agCfmMaintDomainNameOrEmpty ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The data type TmnxDot1agCfmMaintDomainNameOrEmpty specifies a generic
Maintenance Domain Name as described by IEEE8021-CFM-MIB
Dot1agCfmMaintDomainName.
In addition, a zero-length name is also accepted when IEEE8021-CFM-MIB
Dot1agCfmMaintDomainNameType value is set to 'none (1)'."
SYNTAX OCTET STRING (SIZE (0..43))
TmnxDot1agCfmMaintAssocNameType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A value that represents a type (and thereby the format) of a
Dot1agCfmMaintAssocName. The values refer directly to the
Dot1agCfmMaintAssocNameType with the additional ituReserved(xx)
defined for iccBased(32). This is a refinement of the
Dot1agCfmMaintAssocNameType and follows the same rules and details as
it does.
ieeeReserved(0) Reserved for definition by IEEE 802.1
recommend to not use zero unless
absolutely needed.
primaryVid(1) Primary VLAN ID.
12 bits represented in a 2-octet integer:
- 4 least significant bits of the first
byte contains the 4 most significant
bits of the 12 bits primary VID
- second byte contains the 8 least
significant bits of the primary VID
0 1 2 3 4 5 6 7 8
+-+-+-+-+-+-+-+-+
|0 0 0 0| (MSB) |
+-+-+-+-+-+-+-+-+
| VID LSB |
+-+-+-+-+-+-+-+-+
charString(2) RFC2579 DisplayString, except that the
character codes 0-31 (decimal) are not
used. (1..45) octets
unsignedInt16(3) 2-octet integer/big endian
rfc2865VpnId(4) RFC 2685 VPN ID
3 octet VPN authority Organizationally
Unique Identifier followed by 4 octet VPN
index identifying VPN according to the OUI:
0 1 2 3 4 5 6 7 8
+-+-+-+-+-+-+-+-+
| VPN OUI (MSB) |
+-+-+-+-+-+-+-+-+
| VPN OUI |
+-+-+-+-+-+-+-+-+
| VPN OUI (LSB) |
+-+-+-+-+-+-+-+-+
|VPN Index (MSB)|
+-+-+-+-+-+-+-+-+
| VPN Index |
+-+-+-+-+-+-+-+-+
| VPN Index |
+-+-+-+-+-+-+-+-+
|VPN Index (LSB)|
+-+-+-+-+-+-+-+-+
iccBased(32) The ICC value for Y.1731.
It is taken from the ituReserved(xx) range of
the Dot1agCfmMaintAssocNameType."
SYNTAX INTEGER {
primaryVid (1),
charString (2),
unsignedInt16 (3),
rfc2865VpnId (4),
iccBased (32)
}
TmnxDot1agCfmMhfCreation ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates if the Management Entity can create MHFs. This is a
refinement of Dot1agCfmMhfCreation.
The valid values are:
defMHFnone(1) No MHFs can be created for this VID.
defMHFdefault(2) MHFs can be created on this VID on any
Bridge port through which this VID can
pass.
defMHFexplicit(3) MHFs can be created for this VID only on
Bridge ports through which this VID can
pass, and only if a MEP is created at some
lower MD Level.
defMHFstatic (32) multiple MHFs can be created on the
primary VID on any bridge port through
which this primary VID can pass,
provided that any existing MEP is
created at a lower MD level."
REFERENCE
"802.1ag clause 12.14.5.1.3:c and 22.2.3"
SYNTAX INTEGER {
defMHFnone (1),
defMHFdefault (2),
defMHFexplicit (3),
defMHFstatic (32)
}
TmnxDot1agCfmIdPermission ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates what, if anything, is to be included in the Sender ID TLV
transmitted in CCMs, LBMs, LTMs, and LTRs.
This is a refinement of Dot1agCfmIdPermission.
The valid values are:
sendIdNone(1) The Sender ID TLV is not to be sent.
sendIdChassis(2) The Chassis ID Length, Chassis ID
Subtype, and Chassis ID fields of the
Sender ID TLV are to be sent."
REFERENCE
"802.1ag clause 12.14.6.1.3:d and 21.5.3"
SYNTAX INTEGER {
sendIdNone (1),
sendIdChassis (2)
}
TmnxDot1agCfmCcmInterval ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the interval at which CCMs are sent by a MEP. The possible
values are:
interval300Hz(1) CCMs are sent every 3 1/3 milliseconds.
interval10ms(2) CCMs are sent every 10 milliseconds.
interval100ms(3) CCMs are sent every 100 milliseconds.
interval1s(4) CCMs are sent every 1 second.
interval10s(5) CCMs are sent every 10 seconds.
interval1min(6) CCMs are sent every minute.
interval10min(7) CCMs are sent every 10 minutes."
REFERENCE
"802.1ag clauses 12.14.6.1.3:e, 20.8.1 and 21.6.1.3"
SYNTAX INTEGER {
interval300Hz (1),
interval10ms (2),
interval100ms (3),
interval1s (4),
interval10s (5),
interval1min (6),
interval10min (7)
}
TmnxDot1agCfmMdIndexOrNone ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An object of type TmnxDot1agCfmMdIndexOrNone specifies a configurable
index value in the Maintenance Domain table, or indicates that no
index is specified.
Md-index zero (0) specifies that no index is set."
SYNTAX Unsigned32 (0 | 1..4294967295)
TmnxDot1agCfmMaIndexOrNone ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An object of type TmnxDot1agCfmMaIndexOrNone specifies a configurable
index value in the Maintenance Domain table, or indicates that no
index is specified.
Md-index zero (0) specifies that no index is set."
SYNTAX Unsigned32 (0 | 1..4294967295)
tmnxDot1agMIBObjs OBJECT IDENTIFIER ::= { tmnxSRObjs 52 }
tmnxDot1agCfmStack OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 1 }
tmnxDot1agCfmSdpBindStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmSdpBindStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one CFM SDP-Bind Stack table per bridge. It permits the
retrieval of information about the Maintenance Points configured on
any given SDP bindings."
REFERENCE
"802.1ag clauses 12.14.2"
::= { tmnxDot1agCfmStack 1 }
tmnxDot1agCfmSdpBindStackEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmSdpBindStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the tmnxDot1agCfmSdpBindStackTable. This row
behaves exactly like the dot1agCfmStackEntry row."
INDEX {
tmnxDot1agCfmSdpBindStackSdpId,
tmnxDot1agCfmSdpBindStackVcId,
tmnxDot1agCfmSdpBindStackMdLevel,
tmnxDot1agCfmSdpBindStackDirection
}
::= { tmnxDot1agCfmSdpBindStackTable 1 }
TmnxDot1agCfmSdpBindStackEntry ::= SEQUENCE
{
tmnxDot1agCfmSdpBindStackSdpId SdpId,
tmnxDot1agCfmSdpBindStackVcId Unsigned32,
tmnxDot1agCfmSdpBindStackMdLevel Dot1agCfmMDLevel,
tmnxDot1agCfmSdpBindStackDirection Dot1agCfmMpDirection,
tmnxDot1agCfmSdpBindStackMdIndex Unsigned32,
tmnxDot1agCfmSdpBindStackMaIndex Unsigned32,
tmnxDot1agCfmSdpBindStackMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmSdpBindStackMacAddress MacAddress
}
tmnxDot1agCfmSdpBindStackSdpId OBJECT-TYPE
SYNTAX SdpId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpBindStackSdpId specifies the Bridge Port
or aggregated port on which MEPs or MHFs might be configured."
REFERENCE
"802.1ag clause 12.14.2.1.2:a"
::= { tmnxDot1agCfmSdpBindStackEntry 1 }
tmnxDot1agCfmSdpBindStackVcId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpBindStackVcId specifies, along with
tmnxDot1agCfmSdpBindStackSdpId, the SDP Binding for the bridge."
REFERENCE
"802.1ag clause 12.14.2.1.2:d"
::= { tmnxDot1agCfmSdpBindStackEntry 2 }
tmnxDot1agCfmSdpBindStackMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpBindStackMdLevel specifies the MD Level
of the Maintenance Point."
REFERENCE
"802.1ag clause 12.14.2.1.2:b"
::= { tmnxDot1agCfmSdpBindStackEntry 3 }
tmnxDot1agCfmSdpBindStackDirection OBJECT-TYPE
SYNTAX Dot1agCfmMpDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpBindStackDirection specifies the
Direction in which the MP faces on the Bridge Port"
REFERENCE
"802.1ag clause 12.14.2.1.2:c"
::= { tmnxDot1agCfmSdpBindStackEntry 4 }
tmnxDot1agCfmSdpBindStackMdIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpBindStackMdIndex indicates the index of
the Maintenance Domain in the dot1agCfmMdTable to which the MP is
associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:b"
::= { tmnxDot1agCfmSdpBindStackEntry 5 }
tmnxDot1agCfmSdpBindStackMaIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpBindStackMaIndex indicates the index of
the MA in the dot1agCfmMaNetTable and dot1agCfmMaCompTable to which
the MP is associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:c"
::= { tmnxDot1agCfmSdpBindStackEntry 6 }
tmnxDot1agCfmSdpBindStackMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpBindStackMepId indicates if an MEP is
configured, the MEPID, else 0"
REFERENCE
"802.1ag clause 12.14.2.1.3:d"
::= { tmnxDot1agCfmSdpBindStackEntry 7 }
tmnxDot1agCfmSdpBindStackMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpBindStackMacAddress indicates the MAC
address of the MP."
REFERENCE
"802.1ag clause 12.14.2.1.3:e"
::= { tmnxDot1agCfmSdpBindStackEntry 8 }
tmnxDot1agCfmStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one CFM Stack table per bridge. It permits the retrieval of
information about the Maintenance Points configured on any given
interface."
REFERENCE
"802.1ag clauses 12.14.2"
::= { tmnxDot1agCfmStack 2 }
tmnxDot1agCfmStackEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Stack table entry"
INDEX {
tmnxDot1agCfmStackifIndex,
tmnxDot1agCfmStackVlanIdOrNone,
tmnxDot1agCfmStackMdLevel,
tmnxDot1agCfmStackDirection
}
::= { tmnxDot1agCfmStackTable 1 }
TmnxDot1agCfmStackEntry ::= SEQUENCE
{
tmnxDot1agCfmStackifIndex InterfaceIndex,
tmnxDot1agCfmStackVlanIdOrNone Unsigned32,
tmnxDot1agCfmStackMdLevel Dot1agCfmMDLevel,
tmnxDot1agCfmStackDirection Dot1agCfmMpDirection,
tmnxDot1agCfmStackMdIndex Unsigned32,
tmnxDot1agCfmStackMaIndex Unsigned32,
tmnxDot1agCfmStackMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmStackMacAddress MacAddress,
tmnxDot1agCfmStackMPType INTEGER
}
tmnxDot1agCfmStackifIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Bridge Port or aggregated port
on which MEPs or MHFs might be configured.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable, and rearrange the
dot1agCfmStackTable, so that it indexes the entry in the
interface table with the same value of ifAlias that it
indexed before the system restart. If no such entry exists,
then the system SHALL delete all entries in the
dot1agCfmStackTable with the interface index."
REFERENCE
"802.1ag clause 12.14.2.1.2:a"
::= { tmnxDot1agCfmStackEntry 1 }
tmnxDot1agCfmStackVlanIdOrNone OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"VLAN ID to which the MP is attached, or 0, if none."
REFERENCE
"802.1ag clauses 12.14.2.1.2:d, 22.1.7"
::= { tmnxDot1agCfmStackEntry 2 }
tmnxDot1agCfmStackMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MD Level of the Maintenance Point."
REFERENCE
"802.1ag clause 12.14.2.1.2:b"
::= { tmnxDot1agCfmStackEntry 3 }
tmnxDot1agCfmStackDirection OBJECT-TYPE
SYNTAX Dot1agCfmMpDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Direction in which the MP faces on the Bridge Port"
REFERENCE
"802.1ag clause 12.14.2.1.2:c"
::= { tmnxDot1agCfmStackEntry 4 }
tmnxDot1agCfmStackMdIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Maintenance Domain in the dot1agCfmMdTable to which
the MP is associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:b"
::= { tmnxDot1agCfmStackEntry 5 }
tmnxDot1agCfmStackMaIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the MA in the dot1agCfmMaNetTable and
dot1agCfmMaCompTable to which the MP is associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:c"
::= { tmnxDot1agCfmStackEntry 6 }
tmnxDot1agCfmStackMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If an MEP is configured, the MEPID, else 0"
REFERENCE
"802.1ag clause 12.14.2.1.3:d"
::= { tmnxDot1agCfmStackEntry 7 }
tmnxDot1agCfmStackMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the MP."
REFERENCE
"802.1ag clause 12.14.2.1.3:e"
::= { tmnxDot1agCfmStackEntry 8 }
tmnxDot1agCfmStackMPType OBJECT-TYPE
SYNTAX INTEGER {
sap (1),
ethTun (2),
ethRing (3),
facPort (4),
facInterface (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmStackMPType indicates the entity that the
MP is configured on:
sap(1) MP is configured on a SAP
ethTun(2) MP is configured on an ethernet-tunnel
ethRing(3) MP is configured on an ethernet-ring
facPort(4) MP is configured on a facility port
facInterface(5) MP is configured on a facility interface"
::= { tmnxDot1agCfmStackEntry 9 }
tmnxDot1agCfmVStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmVStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one CFM Virtual Stack entry per service. It permits the
retrieval of information about the Maintenance Points configured on
any given virtual Maintenance Association End Point (MEP)."
REFERENCE
"802.1ag clauses 12.14.2"
::= { tmnxDot1agCfmStack 3 }
tmnxDot1agCfmVStackEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmVStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the tmnxDot1agCfmVStackTable.
There exists one row for each configured virtual MEP in the system.
Rows are created and destroyed based on the existence of a virtual
MEP."
INDEX {
tmnxDot1agCfmVStackSvcId,
tmnxDot1agCfmVStackMdLevel,
tmnxDot1agCfmVStackDirection
}
::= { tmnxDot1agCfmVStackTable 1 }
TmnxDot1agCfmVStackEntry ::= SEQUENCE
{
tmnxDot1agCfmVStackSvcId TmnxServId,
tmnxDot1agCfmVStackMdLevel Dot1agCfmMDLevel,
tmnxDot1agCfmVStackDirection Dot1agCfmMpDirection,
tmnxDot1agCfmVStackMdIndex Unsigned32,
tmnxDot1agCfmVStackMaIndex Unsigned32,
tmnxDot1agCfmVStackMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmVStackMacAddress MacAddress
}
tmnxDot1agCfmVStackSvcId OBJECT-TYPE
SYNTAX TmnxServId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmVStackSvcId specifies the service on which
MEPs might be configured."
REFERENCE
"802.1ag clause 12.14.2.1.2:a"
::= { tmnxDot1agCfmVStackEntry 1 }
tmnxDot1agCfmVStackMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmVStackMdLevel specifies the Maintenance
Domain (MD) Level of the Maintenance Point."
REFERENCE
"802.1ag clause 12.14.2.1.2:b"
::= { tmnxDot1agCfmVStackEntry 2 }
tmnxDot1agCfmVStackDirection OBJECT-TYPE
SYNTAX Dot1agCfmMpDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmVStackDirection specifies the direction in
which the Maintenance Point (MP) faces on the service."
REFERENCE
"802.1ag clause 12.14.2.1.2:c"
::= { tmnxDot1agCfmVStackEntry 3 }
tmnxDot1agCfmVStackMdIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmVStackMdIndex indicates the index of the
Maintenance Domain in the dot1agCfmMdTable to which the Maintenance
Point (MP) is associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:b"
::= { tmnxDot1agCfmVStackEntry 4 }
tmnxDot1agCfmVStackMaIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmVStackMaIndex indicates the index of the
Maintenance Association (MA) in the dot1agCfmMaNetTable and
dot1agCfmMaCompTable to which the Maintenance Point (MP) is
associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:c"
::= { tmnxDot1agCfmVStackEntry 5 }
tmnxDot1agCfmVStackMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmVStackMepId indicates if an MEP is
configured, the MEPID, else 0."
REFERENCE
"802.1ag clause 12.14.2.1.3:d"
::= { tmnxDot1agCfmVStackEntry 6 }
tmnxDot1agCfmVStackMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmVStackMacAddress indicates the MAC address
of the MP."
REFERENCE
"802.1ag clause 12.14.2.1.3:e"
::= { tmnxDot1agCfmVStackEntry 7 }
tmnxDot1agCfmPVStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmPVStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one CFM Stack table per bridge. It permits the retrieval of
information about the Maintenance Points (MP) configured on any given
interface."
REFERENCE
"802.1ag clauses 12.14.2"
::= { tmnxDot1agCfmStack 4 }
tmnxDot1agCfmPVStackEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmPVStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Primary VLAN-ID Stack table entry. Entries in this table are MEPs
configured to use the primary VLAN-ID of the Maintenance Association
(MA)."
INDEX {
tmnxDot1agCfmPVStackifIndex,
tmnxDot1agCfmPVStackVlanIdOrNone,
tmnxDot1agCfmPVStackPriVlanId,
tmnxDot1agCfmPVStackMdLevel,
tmnxDot1agCfmPVStackDirection
}
::= { tmnxDot1agCfmPVStackTable 1 }
TmnxDot1agCfmPVStackEntry ::= SEQUENCE
{
tmnxDot1agCfmPVStackifIndex InterfaceIndex,
tmnxDot1agCfmPVStackVlanIdOrNone Unsigned32,
tmnxDot1agCfmPVStackPriVlanId Unsigned32,
tmnxDot1agCfmPVStackMdLevel Dot1agCfmMDLevel,
tmnxDot1agCfmPVStackDirection Dot1agCfmMpDirection,
tmnxDot1agCfmPVStackMdIndex Unsigned32,
tmnxDot1agCfmPVStackMaIndex Unsigned32,
tmnxDot1agCfmPVStackMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmPVStackMacAddress MacAddress
}
tmnxDot1agCfmPVStackifIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Bridge Port or aggregated port
on which MEPs or MHFs might be configured."
REFERENCE
"802.1ag clause 12.14.2.1.2:a"
::= { tmnxDot1agCfmPVStackEntry 1 }
tmnxDot1agCfmPVStackVlanIdOrNone OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"VLAN ID to which the MP is attached, or 0, if none."
REFERENCE
"802.1ag clauses 12.14.2.1.2:d, 22.1.7"
::= { tmnxDot1agCfmPVStackEntry 2 }
tmnxDot1agCfmPVStackPriVlanId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Primary VLAN ID with which the Maintenance Association is
associated."
REFERENCE
"802.1ag clause 12.14.6.1.3:b"
::= { tmnxDot1agCfmPVStackEntry 3 }
tmnxDot1agCfmPVStackMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MD Level of the Maintenance Point."
REFERENCE
"802.1ag clause 12.14.2.1.2:b"
::= { tmnxDot1agCfmPVStackEntry 4 }
tmnxDot1agCfmPVStackDirection OBJECT-TYPE
SYNTAX Dot1agCfmMpDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Direction in which the MP faces on the Bridge Port"
REFERENCE
"802.1ag clause 12.14.2.1.2:c"
::= { tmnxDot1agCfmPVStackEntry 5 }
tmnxDot1agCfmPVStackMdIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Maintenance Domain in the dot1agCfmMdTable to which
the MP is associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:b"
::= { tmnxDot1agCfmPVStackEntry 6 }
tmnxDot1agCfmPVStackMaIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the MA in the dot1agCfmMaNetTable and
dot1agCfmMaCompTable to which the MP is associated, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:c"
::= { tmnxDot1agCfmPVStackEntry 7 }
tmnxDot1agCfmPVStackMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If an MEP is configured, the MEPID, else 0"
REFERENCE
"802.1ag clause 12.14.2.1.3:d"
::= { tmnxDot1agCfmPVStackEntry 8 }
tmnxDot1agCfmPVStackMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the MP."
REFERENCE
"802.1ag clause 12.14.2.1.3:e"
::= { tmnxDot1agCfmPVStackEntry 9 }
tmnxDot1agCfmSdpPVStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmSdpPVStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmSdpPVStackTable contains a read-only copy of the locally
configured information for Maintenance Points (MPs) hosted by Service
Delivery Point (SDP) bindings with Ethernet CFM Primary VLAN support
enabled.
The table is modeled after IEEE8021-CFM-MIB::dot1agCfmStackTable (with
extensions for SDP binding support and Primary VLAN support).
tmnxDot1agCfmPVStackTable is the equivalent table for Service Access
Points (SAPs)."
REFERENCE
"IEEE Std 802.1Q-2014, 'Bridges and Bridged Networks', Section 12.14.2,
'CFM Stack managed object'."
::= { tmnxDot1agCfmStack 5 }
tmnxDot1agCfmSdpPVStackEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmSdpPVStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmSdpPVStackEntry contains a read-only copy of the locally
configured information for an MP direction (e.g. MEPID=1, domain=2,
association=3, direction=down), if a) the MP direction is hosted by an
SDP binding, and b) the MP direction has Primary VLAN support enabled.
A row is created by SROS when an MP direction (hosted by an SDP
binding) has Primary VLAN support enabled.
A row is destroyed by SROS when an MP direction (hosted by an SDP
binding) is destroyed (provided the MP direction had Primary VLAN
support enabled)."
REFERENCE
"IEEE Std 802.1Q-2014, 'Bridges and Bridged Networks', Section 3,
'Definitions'."
INDEX {
tmnxDot1agCfmSdpPVStackSdpId,
tmnxDot1agCfmSdpPVStackVcId,
tmnxDot1agCfmSdpPVStackPriVlanId,
tmnxDot1agCfmSdpPVStackMdLevel,
tmnxDot1agCfmSdpPVStackDirection
}
::= { tmnxDot1agCfmSdpPVStackTable 1 }
TmnxDot1agCfmSdpPVStackEntry ::= SEQUENCE
{
tmnxDot1agCfmSdpPVStackSdpId SdpId,
tmnxDot1agCfmSdpPVStackVcId Unsigned32,
tmnxDot1agCfmSdpPVStackPriVlanId VlanId,
tmnxDot1agCfmSdpPVStackMdLevel Dot1agCfmMDLevel,
tmnxDot1agCfmSdpPVStackDirection Dot1agCfmMpDirection,
tmnxDot1agCfmSdpPVStackMdIndex Unsigned32,
tmnxDot1agCfmSdpPVStackMaIndex Unsigned32,
tmnxDot1agCfmSdpPVStackMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmSdpPVStackMacAddr MacAddress
}
tmnxDot1agCfmSdpPVStackSdpId OBJECT-TYPE
SYNTAX SdpId (1..32767)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackSdpId specifies the SDP identifier
index of the row."
::= { tmnxDot1agCfmSdpPVStackEntry 1 }
tmnxDot1agCfmSdpPVStackVcId OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackVcId specifies the Virtual Circuit
(VC) identifier index of the row. Together,
tmnxDot1agCfmSdpPVStackSdpId and tmnxDot1agCfmSdpPVStackVcId identify
an SDP binding."
::= { tmnxDot1agCfmSdpPVStackEntry 2 }
tmnxDot1agCfmSdpPVStackPriVlanId OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackPriVlanId specifies the Primary
VLAN identifier index of the row."
::= { tmnxDot1agCfmSdpPVStackEntry 3 }
tmnxDot1agCfmSdpPVStackMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackMdLevel specifies the Maintenance
Domain Level index of the row."
::= { tmnxDot1agCfmSdpPVStackEntry 4 }
tmnxDot1agCfmSdpPVStackDirection OBJECT-TYPE
SYNTAX Dot1agCfmMpDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackDirection specifies the MP
direction index (e.g. 'down(1)') of the row."
::= { tmnxDot1agCfmSdpPVStackEntry 5 }
tmnxDot1agCfmSdpPVStackMdIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackMdIndex indicates the Maintenance
Domain for the specified MP direction.
Zero is returned in the case of a MIP created using a default domain
with dot1agCfmDefaultMdMhfCreation set to 'defMHFdefault(2)' or
'defMHFexplicit(3)'."
::= { tmnxDot1agCfmSdpPVStackEntry 6 }
tmnxDot1agCfmSdpPVStackMaIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackMaIndex indicates the Maintenance
Association for the specified MP direction.
Zero is returned in the case of a MIP created using a default domain
with dot1agCfmDefaultMdMhfCreation set to 'defMHFdefault(2)' or
'defMHFexplicit(3)'."
::= { tmnxDot1agCfmSdpPVStackEntry 7 }
tmnxDot1agCfmSdpPVStackMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackMepId indicates the MEPID for the
specified MP direction.
Zero indicates the MP is a MIP."
REFERENCE
"IEEE Std 802.1Q-2014, 'Bridges and Bridged Networks', Section 3,
'Definitions'."
::= { tmnxDot1agCfmSdpPVStackEntry 8 }
tmnxDot1agCfmSdpPVStackMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpPVStackMacAddr indicates the MAC address
for the specified MP direction.
If no MAC address has been locally configured against the MP
direction, the all-zeros MAC address is returned."
::= { tmnxDot1agCfmSdpPVStackEntry 9 }
tmnxDot1agCfmGlobalObjs OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 2 }
tmnxDot1agCfmMcLagConfigGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 1 }
tmnxDot1agCfmMcLagStdbyInactive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMcLagStdbyInactive specifies whether or not
ETH-CFM MEPs configured on Multi-Chassis LAG ports are aware of MC-LAG
port active/standby states.
When this object is 'true (1)', MEPs configured on a Multi-Chassis LAG
port will act as if they are administratively shutdown if running on a
standby port, and will only be operational on an active MC-LAG port.
When this object is 'false (2)', MEPs configured on a Multi-Chassis
LAG port will operate regardless of the MC-LAG port active and standby
states."
DEFVAL { false }
::= { tmnxDot1agCfmMcLagConfigGroup 1 }
tmnxDot1agCfmMcLagPropHoldTime OBJECT-TYPE
SYNTAX Unsigned32 (0..60)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMcLagPropHoldTime specifies the duration, in
seconds, of a timer that is activated when an MC-LAG port or protocol
changes state. While the timer is active, no fault set or clear is
propagated to the MC-LAG SAP's CFM MEP.
The outstanding hold time can be monitored by polling the value of
sapEthCfmMcLagPropHoldTimeRemain for a particular SAP. When set to
the value zero (0), no delay in response to a port or protocol change
will be observed.
This object is meaningful only when tmnxDot1agCfmMcLagStdbyInactive is
set to the value 'enabled (1)', otherwise an SNMP Set operation will
result in an inconsistentValue error and the result of an SNMP Get
operation will be undefined."
DEFVAL { 1 }
::= { tmnxDot1agCfmMcLagConfigGroup 2 }
tmnxDot1agCfmSLMConfigGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 2 }
tmnxDot1agCfmSLMInactivityTimer OBJECT-TYPE
SYNTAX Unsigned32 (10..100)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSLMInactivityTimer specifies the duration,
in seconds, that the system will maintain Synthetic Loss Measurement
(SLM) reply (SLR) data for individual two-way tests in the absence of
receiving SLM frames.
The system may be blocked in responding to new two-way SLM tests due
to an excessive inactive timer duration. In this case, reducing this
object's value, thus reducing the retention time for existing latent
SLR test data, will help free test resources allowing the system to
respond to new two-way SLM tests."
REFERENCE
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)
Section 8.2 Note 2."
DEFVAL { 100 }
::= { tmnxDot1agCfmSLMConfigGroup 1 }
tmnxDot1agCfmStatisticsGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 3 }
tmnxDot1agCfmGlobalPacketStats OBJECT IDENTIFIER ::= { tmnxDot1agCfmStatisticsGroup 1 }
tmnxDot1agCfmGlobalPacketRxCount OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmGlobalPacketRxCount indicates the number of
received ETH-CFM packets."
::= { tmnxDot1agCfmGlobalPacketStats 1 }
tmnxDot1agCfmGlobalPacketTxCount OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmGlobalPacketTxCount indicates the number of
transmitted ETH-CFM packets."
::= { tmnxDot1agCfmGlobalPacketStats 2 }
tmnxDot1agCfmGlobalPacketDropped OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmGlobalPacketDropped indicates the number of
packets dropped by ETH-CFM. A packet is dropped because of resource
contention."
::= { tmnxDot1agCfmGlobalPacketStats 3 }
tmnxDot1agCfmGlobalPacketDiscard OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmGlobalPacketDiscard indicates the number of
packets discarded by ETH-CFM. A packet may be discarded for several
reasons including, but not limited to, malformed PDU, invalid TLVs,
MEP admin down, etc."
::= { tmnxDot1agCfmGlobalPacketStats 4 }
tmnxDot1agCfmGlobalAisTxActive OBJECT-TYPE
SYNTAX Counter32
UNITS "sessions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmGlobalAisTxActive indicates the number of
sessions where fault (AIS or other) is actively being transmitted."
::= { tmnxDot1agCfmGlobalPacketStats 5 }
tmnxDot1agCfmGlobalAisTxFail OBJECT-TYPE
SYNTAX Counter32
UNITS "sessions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmGlobalAisTxFail indicates the number of
sessions where fault (AIS or other) can't be transmitted due to lack
of resources."
::= { tmnxDot1agCfmGlobalPacketStats 6 }
tmnxDot1agCfmComponentLimitTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmComponentLimitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmComponentLimitTable stores the current resource
counts as well as their resource limits for Ethernet Connectivity
Fault Management (ETH-CFM) components in the SROS series system."
::= { tmnxDot1agCfmStatisticsGroup 2 }
tmnxDot1agCfmComponentLimitEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmComponentLimitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmComponentLimitEntry consists of the resource limits
for a particular component of ETH-CFM.
Rows are managed by the system and can not be created or destroyed
using SNMP set requests."
INDEX {
tmnxDot1agCfmCompMajorIndex,
tmnxDot1agCfmCompMinorIndex
}
::= { tmnxDot1agCfmComponentLimitTable 1 }
TmnxDot1agCfmComponentLimitEntry ::= SEQUENCE
{
tmnxDot1agCfmCompMajorIndex Unsigned32,
tmnxDot1agCfmCompMinorIndex Unsigned32,
tmnxDot1agCfmCompName TNamedItem,
tmnxDot1agCfmCompResourceUsage Unsigned32,
tmnxDot1agCfmCompResourceLimit Unsigned32
}
tmnxDot1agCfmCompMajorIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmCompMajorIndex specifies the major
identifier of the ETH-CFM component."
::= { tmnxDot1agCfmComponentLimitEntry 1 }
tmnxDot1agCfmCompMinorIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmCompMinorIndex specifies the minor
identifier of the ETH-CFM component."
::= { tmnxDot1agCfmComponentLimitEntry 2 }
tmnxDot1agCfmCompName OBJECT-TYPE
SYNTAX TNamedItem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmCompName indicates the name of the ETH-CFM
component."
::= { tmnxDot1agCfmComponentLimitEntry 3 }
tmnxDot1agCfmCompResourceUsage OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmCompResourceUsage indicates the current
resource usage for the ETH-CFM component."
::= { tmnxDot1agCfmComponentLimitEntry 4 }
tmnxDot1agCfmCompResourceLimit OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmCompResourceLimit indicates the maximum
resource usage limit for the ETH-CFM component for the SROS series
system."
::= { tmnxDot1agCfmComponentLimitEntry 5 }
tmnxDot1agCfmGlobalOpcodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmGlobalOpcodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmGlobalOpcodeTable consists of global statistics that are
kept in the receive and transmit direction on the node for each CFM
PDU Opcode."
REFERENCE
"Y.1731 clauses 8 and 9"
::= { tmnxDot1agCfmStatisticsGroup 3 }
tmnxDot1agCfmGlobalOpcodeEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmGlobalOpcodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Global Opcode Stats Table entry."
INDEX { tmnxDot1agCfmGlobalOpcode }
::= { tmnxDot1agCfmGlobalOpcodeTable 1 }
TmnxDot1agCfmGlobalOpcodeEntry ::= SEQUENCE
{
tmnxDot1agCfmGlobalOpcode Dot1agCfmStatisticOpcodeName,
tmnxDot1agCfmGlobalOpcodeRx Counter32,
tmnxDot1agCfmGlobalOpcodeTx Counter32
}
tmnxDot1agCfmGlobalOpcode OBJECT-TYPE
SYNTAX Dot1agCfmStatisticOpcodeName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Integer that defines which CFM PDU Opcode the statistics refer to."
::= { tmnxDot1agCfmGlobalOpcodeEntry 1 }
tmnxDot1agCfmGlobalOpcodeRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of PDUs received on the node with the specified
Opcode."
::= { tmnxDot1agCfmGlobalOpcodeEntry 2 }
tmnxDot1agCfmGlobalOpcodeTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of PDUs transmitted from the node with the specified
Opcode."
::= { tmnxDot1agCfmGlobalOpcodeEntry 3 }
tmnxDot1agCfmSystemScalarsGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 4 }
tmnxDot1agCfmGraceTxEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmGraceTxEnable specifies whether or not grace
period notifications will be sent to the ETH-CFM remote MEP peers. The
value 'true' enables grace period notifications, and the value 'false'
suppresses the notifications.
During an outage, the modification of this object from 'true' to
'false' will cause an immediate clear of all grace period
notifications, after which no further notifications will be sent. A
modification of this object from 'false' to 'true' will not enable the
transmission of grace period for any outages currently in progress but
will take effect for subsequent outages."
DEFVAL { true }
::= { tmnxDot1agCfmSystemScalarsGroup 1 }
tmnxDot1agCfmGracePeriod OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmGracePeriod indicates whether or not the
node is locally executing a grace period. A value of 'true' indicates
that all peer timeouts are extended locally and eligible MEPs are
transmitting grace period information. A value of 'false' indicates
no grace period information is transmitted and standard values are
used for timing out remote peers.
Note that for a local MEP to be eligible for grace period transmission
it must be admin up and ccm-enabled. Additionally, for any
transmission to occur tmnxDot1agCfmGraceTxEnable must be set to
'true'."
::= { tmnxDot1agCfmSystemScalarsGroup 2 }
tmnxDot1agCfmSenderIdType OBJECT-TYPE
SYNTAX LldpChassisIdSubtype
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSenderIdType specifies the type of sender
identification that is transmitted in CFM PDUs generated from this
system.
The value of 'chassisComponent (1)' indicates that the system's name
(TIMETRA-CHASSIS-MIB::tmnxChassisName) is inserted in transmitted
PDUs, while 'local (7)' indicates that the value as defined in
tmnxDot1agCfmSenderIdName is transmitted."
DEFVAL { chassisComponent }
::= { tmnxDot1agCfmSystemScalarsGroup 3 }
tmnxDot1agCfmSenderIdName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..45))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSenderIdName specifies the locally defined
sender-id name that is inserted in all CFM transmitted PDUs. The value
of this object is only meaningful if the value of
tmnxDot1agCfmSenderIdType is set to the value 'local (7)'. Otherwise
the value of this object MUST be the empty string.
The value of this object MUST be set to a non-empty string in the same
SNMP PDU as the modification of tmnxDot1agCfmSenderIdType when the
type is assigned to the value 'local (7)'. Modification of the type
away from 'local (7)' will automatically reset the value to its
default value."
DEFVAL { "" }
::= { tmnxDot1agCfmSystemScalarsGroup 4 }
tmnxDot1agAutoIndexGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 5 }
tmnxDot1agAutoMdIndexRangeStart OBJECT-TYPE
SYNTAX TmnxDot1agCfmMdIndexOrNone
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The tmnxDot1agAutoMdIndexRangeStart specifies start of the CFM
Maintenance Domain index range to be used in model-driven user
interfaces"
DEFVAL { 0 }
::= { tmnxDot1agAutoIndexGroup 1 }
tmnxDot1agAutoMdIndexRangeEnd OBJECT-TYPE
SYNTAX TmnxDot1agCfmMdIndexOrNone
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The tmnxDot1agAutoMdIndexRangeEnd specifies end of the CFM Maintenance
Domain index range to be used in model-driven user interfaces."
DEFVAL { 0 }
::= { tmnxDot1agAutoIndexGroup 2 }
tmnxDot1agAutoMaIndexRangeStart OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaIndexOrNone
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The tmnxDot1agAutoMaIndexRangeStart specifies the start of the CFM
Maintenance Association index range to be used in model-driven user
interfaces"
DEFVAL { 0 }
::= { tmnxDot1agAutoIndexGroup 3 }
tmnxDot1agAutoMaIndexRangeEnd OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaIndexOrNone
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The tmnxDot1agAutoMaIndexRangeEnd specifies the end of the CFM
Maintenance Association index range to be used in model-driven user
interfaces."
DEFVAL { 0 }
::= { tmnxDot1agAutoIndexGroup 4 }
tmnxDot1agCfmManagementObjects OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 3 }
tmnxDot1agCfmMepMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepMgmtTable manages the row creation and deletion of
dot1agCfmMepTable rows. This table replaces the standard row creation
model for Dot1ag CFM MEPs to better facilitate Nokia SROS series
requirements. The use of writing to the
IEEE-8021-CFM-MIB::dot1agCfmMepRowStatus object is deprecated and
should be discouraged in favor of this table."
::= { tmnxDot1agCfmManagementObjects 1 }
tmnxDot1agCfmMepMgmtEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepMgmtEntry consists of the configuration objects
used for the purpose of row creation for Nokia SROS Dot1ag MEPs. To
create a MEP one must specify its type and endpoint association."
AUGMENTS { dot1agCfmMepEntry }
::= { tmnxDot1agCfmMepMgmtTable 1 }
TmnxDot1agCfmMepMgmtEntry ::= SEQUENCE
{
tmnxDot1agCfmMepMgmtRowStatus RowStatus,
tmnxDot1agCfmMepMgmtType INTEGER,
tmnxDot1agCfmMepMgmtServiceId TmnxServId,
tmnxDot1agCfmMepMgmtIfIndex InterfaceIndexOrZero,
tmnxDot1agCfmMepMgmtPrimaryVid Unsigned32,
tmnxDot1agCfmMepMgmtSdpId SdpId,
tmnxDot1agCfmMepMgmtVcId Unsigned32,
tmnxDot1agCfmMepMgmtFcltyIfIndex InterfaceIndexOrZero,
tmnxDot1agCfmMepMgmtFcltyVlanId VlanIdOrNone,
tmnxDot1agCfmMepMgmtDirection Dot1agCfmMpDirection
}
tmnxDot1agCfmMepMgmtRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtRowStatus specifies the row status of
the dot1ag CFM MEP. This object replaces the use of the
IEEE-8021-CFM-MIB::dot1agCfmMepRowStatus object."
::= { tmnxDot1agCfmMepMgmtEntry 1 }
tmnxDot1agCfmMepMgmtType OBJECT-TYPE
SYNTAX INTEGER {
default (0),
facilityPort (1),
facilityInterface (2),
sapPrimaryVlan (3),
sdpPrimaryVlan (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtType specifies the type of the
specified MEP.
Code Points
-----------
default(0)
The MEP resides on a Service Access Point (SAP) or Service Delivery
Point (SDP) binding. The MEP has primary VLAN processing disabled.
OR
The MEP resides on a service.
facilityPort(1)
The MEP resides on a port or a Link Aggregation Group (LAG).
facilityInterface(2)
The MEP resides on a router interface.
sapPrimaryVlan(3)
The MEP resides on a SAP. The MEP has primary VLAN processing
enabled. This code point is rejected if the MEP's
IEEE8021-CFM-MIB::dot1agCfmMaCompPrimaryVlanId is zero.
sdpPrimaryVlan(4)
The MEP resides on an SDP binding. The MEP has primary VLAN
processing enabled. This code point is rejected if the MEP's
IEEE8021-CFM-MIB::dot1agCfmMaCompPrimaryVlanId is zero.
This object must be specified during row creation."
DEFVAL { default }
::= { tmnxDot1agCfmMepMgmtEntry 2 }
tmnxDot1agCfmMepMgmtServiceId OBJECT-TYPE
SYNTAX TmnxServId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtServiceId specifies the service to
which the virtual MEP is attached.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepSvcId.
This object may be specified during row creation when
tmnxDot1agCfmMepMgmtType is set to the value 'default'."
::= { tmnxDot1agCfmMepMgmtEntry 3 }
tmnxDot1agCfmMepMgmtIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtIfIndex specifies, along with
tmnxDot1agCfmMepMgmtPrimaryVid, the interface index of the interface
to which the MEP is attached.
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMepIfIndex.
This object may be specified during row creation when
tmnxDot1agCfmMepMgmtType is set to either the value 'default' or
'sapPrimaryVlan'."
::= { tmnxDot1agCfmMepMgmtEntry 4 }
tmnxDot1agCfmMepMgmtPrimaryVid OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtPrimaryVid specifies, along with
tmnxDot1agCfmMepMgmtIfIndex, the Primary VID of the MEP.
This object refers directly to
IEEE8021-CFM-MIB::dot1agCfmMepPrimaryVid.
This object must be specified during row creation when
tmnxDot1agCfmMepMgmtIfIndex is specified."
::= { tmnxDot1agCfmMepMgmtEntry 5 }
tmnxDot1agCfmMepMgmtSdpId OBJECT-TYPE
SYNTAX SdpId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtSdpId specifies, along with
tmnxDot1agCfmMepMgmtVcId, the SDP-Binding to which the MEP is
attached.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepSdpId.
This object may be specified during row creation when
tmnxDot1agCfmMepMgmtType is set to the value 'default'."
::= { tmnxDot1agCfmMepMgmtEntry 6 }
tmnxDot1agCfmMepMgmtVcId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtVcId specifies, along with
tmnxDot1agCfmMepMgmtSdpId, the SDP-Binding to which the MEP is
attached.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepVcId.
This object must be specified during row creation when
tmnxDot1agCfmMepMgmtSdpId is specified."
::= { tmnxDot1agCfmMepMgmtEntry 7 }
tmnxDot1agCfmMepMgmtFcltyIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtFcltyIfIndex specifies, along with
tmnxDot1agCfmMepMgmtFcltyVlanId, the port or interface to which this
MEP is attached.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepFacilityIfIndex.
This object must be specified during row creation when
tmnxDot1agCfmMepMgmtType is set to a 'facility' value."
::= { tmnxDot1agCfmMepMgmtEntry 8 }
tmnxDot1agCfmMepMgmtFcltyVlanId OBJECT-TYPE
SYNTAX VlanIdOrNone
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtFcltyVlanId specifies, along with
tmnxDot1agCfmMepMgmtFcltyIfIndex, the port or interface to which this
MEP is attached.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepFacilityVlanId.
This object must be specified during row creation when
tmnxDot1agCfmMepMgmtFcltyIfIndex is specified."
::= { tmnxDot1agCfmMepMgmtEntry 9 }
tmnxDot1agCfmMepMgmtDirection OBJECT-TYPE
SYNTAX Dot1agCfmMpDirection
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMgmtDirection specifies the direction in
which the MEP faces on the Bridge port.
This object refers directly to
IEEE8021-CFM-MIB::dot1agCfmMepDirection.
This object applies to any MEP type as specified by the object
tmnxDot1agCfmMepMgmtType."
DEFVAL { down }
::= { tmnxDot1agCfmMepMgmtEntry 50 }
tmnxDot1agCfmMd OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 5 }
tmnxDot1agCfmMdTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMdTable extends the functionality of the
dot1agCfmMdTable for the SROS series systems."
::= { tmnxDot1agCfmMd 1 }
tmnxDot1agCfmMdEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMdEntry consists of the objects used to enhance the
Maintenance Domain functionality.
Use of AUGMENTS clause implies a one-to-one dependent relationship
between the base table, dot1agCfmMdTable, and the augmenting table,
tmnxDot1agCfmMdTable. This in effect extends the dot1agCfmMdTable with
additional columns.
Creation (or deletion) of a row in the dot1agCfmMdTable results in the
same fate for the row in the tmnxDot1agCfmMdTable."
AUGMENTS { dot1agCfmMdEntry }
::= { tmnxDot1agCfmMdTable 1 }
TmnxDot1agCfmMdEntry ::= SEQUENCE
{
tmnxDot1agCfmMdCreationOrigin TmnxCreateOrigin,
tmnxDot1agCfmMdAdminName TLNamedItemOrEmpty
}
tmnxDot1agCfmMdCreationOrigin OBJECT-TYPE
SYNTAX TmnxCreateOrigin
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMdCreationOrigin indicates the mechanism
which created this CFM Maintenance Domain."
::= { tmnxDot1agCfmMdEntry 1 }
tmnxDot1agCfmMdAdminName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMdAdminName indicates a name that can be
used to uniquely identify a CFM Maintenance Domain. Historically, only
the arbitrary integer index, dot1agCfmMdIndex, would be used for this
purpose. A string provides greater flexibility and allows some amount
of context to also be included."
DEFVAL { ''H }
::= { tmnxDot1agCfmMdEntry 2 }
tmnxDot1agCfmMa OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 6 }
tmnxDot1agCfmMaNetTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMaNetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaNetTable AUGMENTS the standard MIB table,
dot1agCfmMaNetTable. This table is used to enhance Maintenance
Association functionality for Ethernet Connectivity Fault Management
(ETH-CFM)."
::= { tmnxDot1agCfmMa 1 }
tmnxDot1agCfmMaNetEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaNetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaNetEntry consists of the configuration objects used
to enhance the Maintenance Association functionality."
AUGMENTS { dot1agCfmMaNetEntry }
::= { tmnxDot1agCfmMaNetTable 1 }
TmnxDot1agCfmMaNetEntry ::= SEQUENCE
{
tmnxDot1agCfmMaNetHoldDownTimer Unsigned32,
tmnxDot1agCfmMaNetTotalMEPCount Counter32,
tmnxDot1agCfmMaNetAutoDiscAdmin TruthValue,
tmnxDot1agCfmMaNetIdPermission TmnxDot1agCfmIdPermission,
tmnxDot1agCfmMaNetAdminName TLNamedItemOrEmpty
}
tmnxDot1agCfmMaNetHoldDownTimer OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..1000)
UNITS "centiseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaNetHoldDownTimer specifies the time, in
centiseconds, that a MEP in the association will delay declaring a
fault. This delay is added on to the existing
3.5 * dot1agCfmMaNetCcmInterval value used to determine if a
connectivity fault to the peer should be raised.
A value of zero (0) indicates that no additional delay should be added
to the existing 3.5 * dot1agCfmMaNetCcmInterval value."
DEFVAL { 0 }
::= { tmnxDot1agCfmMaNetEntry 1 }
tmnxDot1agCfmMaNetTotalMEPCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaNetTotalMEPCount indicates the number of
unique MEPs configured (both local and remote) that are associated
with this MA.
When the number of MEPs exceed the normal MA limits, the MA is
considered to be an extended MA and will use a resource from the
'Extended MA' resource entry in tmnxDot1agCfmComponentLimitTable."
::= { tmnxDot1agCfmMaNetEntry 2 }
tmnxDot1agCfmMaNetAutoDiscAdmin OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaNetAutoDiscAdmin specifies if remote MEP
automatic discovery is enabled in the association. A value of 'true'
indicates that a new remote MEP entry will be added to the
dot1agCfmMepDbTable when the node receives a CCM PDU from a remote
MEP that is not yet in that table (up to the maximum limit of MEPs
allowed in the association). A value of 'false' indicates that remote
MEPs must be manually configured in the association
dot1agCfmMaMepListTable before being added to the association
dot1agCfmMepDbTable."
DEFVAL { false }
::= { tmnxDot1agCfmMaNetEntry 3 }
tmnxDot1agCfmMaNetIdPermission OBJECT-TYPE
SYNTAX TmnxDot1agCfmIdPermission
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enumerated value indicating what, if anything, is to be included in
the Sender ID TLV (21.5.3) transmitted by MPs configured in this MA.
This object is configurable on MA entries that do not consist of
component entries."
REFERENCE
"802.1ag clause 12.14.6.1.3:d"
DEFVAL { sendIdNone }
::= { tmnxDot1agCfmMaNetEntry 4 }
tmnxDot1agCfmMaNetAdminName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaNetAdminName indicates a name that can be
used to uniquely identify a CFM Maintenance Association. Historically,
only the arbitrary integer index, dot1agCfmMaIndex, would be used for
this purpose. A string provides greater flexibility and allows some
amount of context to also be included."
DEFVAL { ''H }
::= { tmnxDot1agCfmMaNetEntry 5 }
tmnxDot1agCfmMaCompTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMaCompEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaCompTable AUGMENTS the standard MIB table,
dot1agCfmMaCompTable. This table is used to enhance Maintenance
Association functionality for Ethernet Connectivity Fault Management
(ETH-CFM)."
::= { tmnxDot1agCfmMa 2 }
tmnxDot1agCfmMaCompEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaCompEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaCompEntry consists of the configuration objects
used to enhance the Maintenance Association functionality."
AUGMENTS { dot1agCfmMaCompEntry }
::= { tmnxDot1agCfmMaCompTable 1 }
TmnxDot1agCfmMaCompEntry ::= SEQUENCE
{ tmnxDot1agCfmMaCompMipLtrPrio Unsigned32 }
tmnxDot1agCfmMaCompMipLtrPrio OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaCompMipLtrPrio specifies at what priority
the link-trace response frames should be transmitted for a MIP
request."
DEFVAL { 7 }
::= { tmnxDot1agCfmMaCompEntry 1 }
tmnxDot1agCfmMaMepListTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMaMepListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaMepListTable extends the functionality of the
dot1agCfmMaMepListTable for the SROS series systems."
::= { tmnxDot1agCfmMa 3 }
tmnxDot1agCfmMaMepListEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaMepListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaMepListEntry augments the standard MIB entry for
the purpose of extending functionality for the SROS series systems for
the Dot1ag CFM MEP Lists. Rows are created and destroyed by the system
through the row status field in dot1agCfmMaMepListEntry."
AUGMENTS { dot1agCfmMaMepListEntry }
::= { tmnxDot1agCfmMaMepListTable 1 }
TmnxDot1agCfmMaMepListEntry ::= SEQUENCE
{
tmnxDot1agCfmMaMepListMacAddress MacAddress,
tmnxDot1agCfmMaMepListAutoDiscvd TruthValue
}
tmnxDot1agCfmMaMepListMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMepListMacAddress specifies the target
unicast MAC address used for transmitting CFM packets to the remote
MEPs for the specified MEPID.
Setting a unicast MAC address restricts the number of MEPIDs that can
be configured for an individual MA to a maximum of one (1). Setting
the address back to the default value will remove this restriction and
will result in the regular CCM multicast address being used. This
value cannot be set to any multicast or broadcast address."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMaMepListEntry 1 }
tmnxDot1agCfmMaMepListAutoDiscvd OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMepListAutoDiscvd specifies whether or not
the remote peer was automatically discovered ('true') or not. Auto-
discovered remote peers are created by the system only and are of a
'volatile' storage type. Specifying the value of 'false' will mark an
auto-discovered remote peer as permanently configured.
To reset a configured remote peer to auto-discovered a manager must
destroy the corresponding dot1agCfmMaMepListEntry."
DEFVAL { false }
::= { tmnxDot1agCfmMaMepListEntry 2 }
tmnxDot1agCfmMep OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 7 }
tmnxDot1agCfmMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments the Maintenance Association End Point (MEP) table
of the IEEE8021-CFM-MIB."
::= { tmnxDot1agCfmMep 1 }
tmnxDot1agCfmMepEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the tmnxDot1agCfmMepTable. This row exists only if
the association dot1agCfmMepEntry is active."
AUGMENTS { dot1agCfmMepEntry }
::= { tmnxDot1agCfmMepTable 1 }
TmnxDot1agCfmMepEntry ::= SEQUENCE
{
tmnxDot1agCfmMepSdpId SdpId,
tmnxDot1agCfmMepVcId Unsigned32,
tmnxDot1agCfmMepMacAddress MacAddress,
tmnxDot1agCfmMepAisEnable TruthValue,
tmnxDot1agCfmMepAisMegLevel BITS,
tmnxDot1agCfmMepAisPriority Unsigned32,
tmnxDot1agCfmMepAisInterval Unsigned32,
tmnxDot1agCfmMepEthRxAisInterval Unsigned32,
tmnxDot1agCfmMepEthRxAis TruthValue,
tmnxDot1agCfmMepEthAisTxCount Counter32,
tmnxDot1agCfmMepEthTestEnable TruthValue,
tmnxDot1agCfmMepEthTestPattern INTEGER,
tmnxDot1agCfmMepEthTestMacAddr MacAddress,
tmnxDot1agCfmMepEthTestDataLen Unsigned32,
tmnxDot1agCfmMepEthTestPriority Unsigned32,
tmnxDot1agCfmMepOWDTMacAddress MacAddress,
tmnxDot1agCfmMepOWDTPriority Unsigned32,
tmnxDot1agCfmMepTWDTMacAddress MacAddress,
tmnxDot1agCfmMepTWDTPriority Unsigned32,
tmnxDot1agCfmMepSvcId TmnxServId,
tmnxDot1agCfmMepControlMep TruthValue,
tmnxDot1agCfmMepEthTestThreshold Unsigned32,
tmnxDot1agCfmMepOWDTThreshold Unsigned32,
tmnxDot1agCfmMepFaultPropagation INTEGER,
tmnxDot1agCfmMepFacilityIfIndex InterfaceIndexOrZero,
tmnxDot1agCfmMepFacilityVlanId VlanIdOrNone,
tmnxDot1agCfmMepFacilityType INTEGER,
tmnxDot1agCfmMepFcltyFaultNotify TruthValue,
tmnxDot1agCfmMepDescription TItemDescription,
tmnxDot1agCfmMepMcLagInactive INTEGER,
tmnxDot1agCfmMepCcmPaddingSize Unsigned32,
tmnxDot1agCfmMepCcmIgnoreTLVs BITS,
tmnxDot1agCfmMepCsfEnable TruthValue,
tmnxDot1agCfmMepCsfRxMultiplier Unsigned32,
tmnxDot1agCfmMepCsfRxState INTEGER,
tmnxDot1agCfmMepCsfRxInterval Unsigned32,
tmnxDot1agCfmMepCsfRxCount Counter32,
tmnxDot1agCfmMepEthAisTxFail Counter32,
tmnxDot1agCfmMepTxLbmTimeout Unsigned32,
tmnxDot1agCfmMepTxLbmInterval Unsigned32,
tmnxDot1agCfmMepLbmPaddingSize Unsigned32,
tmnxDot1agCfmMepIfSupportEnable TruthValue,
tmnxDot1agCfmMepAisLowPrioDef Dot1agCfmLowestAlarmPri,
tmnxDot1agCfmMepCollectLmmStats TruthValue,
tmnxDot1agCfmMepCreationOrigin TmnxCreateOrigin,
tmnxDot1agCfmMepEthTestTargMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmMepEthTestLstDstMac MacAddress,
tmnxDot1agCfmMepOWDTTargetMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmMepOWDTLstDstMac MacAddress,
tmnxDot1agCfmMepTWDTTargetMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmMepTWDTLstDstMac MacAddress,
tmnxDot1agCfmMepCollLmmFcSts TFCSet,
tmnxDot1agCfmMepCollLmmFcStsInP TFCSet,
tmnxDot1agCfmMepTxEthVsmGrace TruthValue,
tmnxDot1agCfmMepRxEthVsmGrace TruthValue,
tmnxDot1agCfmMepTxEthEd TruthValue,
tmnxDot1agCfmMepRxEthEd TruthValue,
tmnxDot1agCfmMepEthEdMaxDurRx Unsigned32,
tmnxDot1agCfmMepEthEdPriority Integer32,
tmnxDot1agCfmMepLbmSvcActResp TruthValue,
tmnxDot1agCfmMepEthBnReceive TruthValue,
tmnxDot1agCfmMepEthBnRxUpdPacing Unsigned32,
tmnxDot1agCfmMepInstallMep TruthValue
}
tmnxDot1agCfmMepSdpId OBJECT-TYPE
SYNTAX SdpId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSdpId specifies, along with the
tmnxDot1agCfmMepVcId, the SDP-Binding within a bridge port, to which
the MEP is attached.
This object is applicable to SDP-Bindings only, and MUST be set to the
null ID (0) when dot1agCfmMepIfIndex, dot1agCfmMepPrimaryVid,
tmnxDot1agCfmMepSvcId, tmnxDot1agCfmMepFacilityIfIndex,
tmnxDot1agCfmMepFacilityVlanId, or tmnxDot1agCfmMepFacilityType is
non-zero. When this object is applicable (non-zero), the above objects
MUST be set to zero (0).
Once set, this object can not be modified."
REFERENCE
"802.1ag clause 12.14.2.1.2:a"
::= { tmnxDot1agCfmMepEntry 1 }
tmnxDot1agCfmMepVcId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepVcId specifies, along with
tmnxDot1agCfmMepSdpId, the SDP Binding for the bridge.
tmnxDot1agCfmMepVcId is applicable to SDP-Bindings only, and MUST be
set to zero (0) when dot1agCfmMepIfIndex, dot1agCfmMepPrimaryVid
tmnxDot1agCfmMepSvcId, tmnxDot1agCfmMepFacilityIfIndex,
tmnxDot1agCfmMepFacilityVlanId, or tmnxDot1agCfmMepFacilityType is
non-zero. When this object is applicable (non-zero), the above objects
MUST be set to zero (0).
Once set, this object can not be modified."
REFERENCE
"802.1ag clause 12.14.2.1.2:d"
::= { tmnxDot1agCfmMepEntry 2 }
tmnxDot1agCfmMepMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMacAddress specifies the MAC address that
is assigned to dot1agCfmMepMacAddress."
REFERENCE
"802.1ag clause 12.14.7.1.3:i and 19.4"
::= { tmnxDot1agCfmMepEntry 3 }
tmnxDot1agCfmMepAisEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepAisEnable specifies whether AIS frames
are generated from the Maintenance Entity Group (MEG)."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 4 }
tmnxDot1agCfmMepAisMegLevel OBJECT-TYPE
SYNTAX BITS {
level1 (0),
level2 (1),
level3 (2),
level4 (3),
level5 (4),
level6 (5),
level7 (6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepAisMegLevel specifies the levels that
should be notified to suppress alarms resulting from defect conditions
detected by the MEP."
DEFVAL { {} }
::= { tmnxDot1agCfmMepEntry 5 }
tmnxDot1agCfmMepAisPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepAisPriority specifies at what priority
the AIS frames should be transmitted."
DEFVAL { 7 }
::= { tmnxDot1agCfmMepEntry 6 }
tmnxDot1agCfmMepAisInterval OBJECT-TYPE
SYNTAX Unsigned32 (1 | 60)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepAisInterval specifies at what intervals
to transmit AIS frames."
DEFVAL { 1 }
::= { tmnxDot1agCfmMepEntry 7 }
tmnxDot1agCfmMepEthRxAisInterval OBJECT-TYPE
SYNTAX Unsigned32 (1 | 60)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthRxAisInterval indicates the AIS
Interval received in the last AIS Frame."
DEFVAL { 1 }
::= { tmnxDot1agCfmMepEntry 8 }
tmnxDot1agCfmMepEthRxAis OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthRxAis indicates the MEP is receiving
AIS test frames from one or more of its sub-layer MEPs."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 9 }
tmnxDot1agCfmMepEthAisTxCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthAisTxCount indicates number of AIS
frames transmitted on the MEP."
::= { tmnxDot1agCfmMepEntry 10 }
tmnxDot1agCfmMepEthTestEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthTestEnable specifies whether Ethernet
test frames are to be generated on transmission or processed on
reception. If this object is set to 'false', then
tmnxDot1agCfmMepEthTestPattern is undefined.
When this object is set to 'true', tmnxDot1agCfmMepEthTestPattern is
reset to its default value, unless tmnxDot1agCfmMepEthTestPattern is
set to a specific value in the same SNMP PDU."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 11 }
tmnxDot1agCfmMepEthTestPattern OBJECT-TYPE
SYNTAX INTEGER {
allZerosNoCrc (0),
allZerosCrc (1),
prbsNoCrc (2),
prbsCrc (3),
allOnesNoCrc (4),
allOnesCrc (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthTestPattern specifies the data-content
of the AIS test frames. 'allZerosNoCrc (0)' and 'allZerosCrc (1)'
specifies the data content as all zero values (without and with CRC
calculations respectively). 'prbsNoCrc (3) and 'prbsCrc (4) specifies
the data content as pseudo random bit sequence (without and with CRC
calculations respectively). 'allOnesNoCrc (4)' and 'allOnesCrc (5)',
specifies the data content as all ones (without and with CRC
calculations respectively).
This object is only applicable if tmnxDot1agCfmMepEthTestEnable is set
to 'true'."
DEFVAL { allZerosNoCrc }
::= { tmnxDot1agCfmMepEntry 12 }
tmnxDot1agCfmMepEthTestMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthTestMacAddr specifies the MAC address
of the target to whom the Eth-test frames are sent.
Setting this object will trigger the test frame to be sent. Once the
test is complete, the object will revert to the default value,
indicating that another test is possible."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepEntry 13 }
tmnxDot1agCfmMepEthTestDataLen OBJECT-TYPE
SYNTAX Unsigned32 (64..1500)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthTestDataLen specifies the length of
the data sent in an Eth-test frame. The contents of the data is
specified by the tmnxDot1agCfmMepEthTestPattern object."
DEFVAL { 64 }
::= { tmnxDot1agCfmMepEntry 14 }
tmnxDot1agCfmMepEthTestPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthTestPriority specifies the priority
used in generating Eth-Test frames."
DEFVAL { 7 }
::= { tmnxDot1agCfmMepEntry 15 }
tmnxDot1agCfmMepOWDTMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepOWDTMacAddress specifies the MAC address
used as a target for the One-Way-Delay Test (OWDT).
Setting this object will trigger a One-Way-Delay test to the specified
MAC address.
Upon completion of the test, the MacAddress will revert to its default
value, indicating that another test is possible."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepEntry 16 }
tmnxDot1agCfmMepOWDTPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepOWDTPriority specifies the priority used
in the generated test frame for the One-Way-Delay test."
DEFVAL { 7 }
::= { tmnxDot1agCfmMepEntry 17 }
tmnxDot1agCfmMepTWDTMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTWDTMacAddress specifies the MAC address
used as a target for the Two-Way-Delay Test (TWDT).
Setting this object will trigger a Two-Way-Delay test to the specified
MAC address.
Upon completion of the test, the MacAddress will revert to its default
value, indicating that another test is possible."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepEntry 18 }
tmnxDot1agCfmMepTWDTPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTWDTPriority specifies the priority used
in the generated test frame for the Two-Way-Delay test."
DEFVAL { 7 }
::= { tmnxDot1agCfmMepEntry 19 }
tmnxDot1agCfmMepSvcId OBJECT-TYPE
SYNTAX TmnxServId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSvcId specifies the service to which the
virtual MEP is attached.
tmnxDot1agCfmMepSvcId is applicable to virtual MEPs only, and MUST
be set to zero (0) when dot1agCfmMepIfIndex, dot1agCfmMepPrimaryVid,
tmnxDot1agCfmMepSdpId, tmnxDot1agCfmMepVcId,
tmnxDot1agCfmMepFacilityIfIndex, tmnxDot1agCfmMepFacilityVlanId, or
tmnxDot1agCfmMepFacilityType is non-zero. When this object is
applicable (non-zero), the above objects MUST be set to zero (0).
Once set, this object can not be modified."
::= { tmnxDot1agCfmMepEntry 20 }
tmnxDot1agCfmMepControlMep OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepControlMep specifies whether or not the
operational state of the MEP is used by the management entity over
which this MEP is configured."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 21 }
tmnxDot1agCfmMepEthTestThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..11840)
UNITS "bit errors"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthTestThreshold specifies when a
tmnxDot1agCfmMepEthTestComplete notification is sent. If
tmnxDot1agCfmMepEthTestThreshold is set to zero (0), a notification is
sent on the completion of any test for this MEP. Otherwise the
threshold must be exceeded and/or CRC failures must be detected to
send the notification."
DEFVAL { 1 }
::= { tmnxDot1agCfmMepEntry 22 }
tmnxDot1agCfmMepOWDTThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepOWDTThreshold specifies when a
tmnxDot1agCfmMepDMTestComplete notification is sent for a
one-way-delay test. If tmnxDot1agCfmMepOWDTThreshold is set to zero
(0), a notification is sent on the completion of any
one-way-delay-test for this MEP. Otherwise the threshold must be
exceeded to send the notification."
DEFVAL { 3 }
::= { tmnxDot1agCfmMepEntry 23 }
tmnxDot1agCfmMepFaultPropagation OBJECT-TYPE
SYNTAX INTEGER {
disabled (0),
useIfStatusTLV (1),
suspendCCM (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFaultPropagation specifies what action
should be taken by the MEP if a fault is detected in the service
containing the MEP. It also specifies if the MEP should propagate
a fault that it has detected into the service.
When this object is set to 'disabled (0)', no additional fault
propagation will occur. When this object is set to 'useIfStatusTLV
(1)', the MEP will send an interface status TLV in the next CCM
indicating fault when fault is detected, even if the MEP itself has
not detected a fault. When this object is set to 'suspendCCM (2)',
faults will be propagated by stopping the regular CCM transmissions
entirely. Once the fault is cleared, the regular CCM transmissions
will resume. Additionally, when the value of
tmnxDot1agCfmMepFaultPropagation is different than 'disabled (0)', a
defect detected by the MEP will be propagated into the service."
DEFVAL { disabled }
::= { tmnxDot1agCfmMepEntry 24 }
tmnxDot1agCfmMepFacilityIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFacilityIfIndex specifies, along with
tmnxDot1agCfmMepFacilityVlanId and tmnxDot1agCfmMepFacilityType, the
port or interface associated with this MEP.
The tmnxDot1agCfmMepFacilityIfIndex is applicable to facility MEPs
only, and MUST be set to zero (0) when dot1agCfmMepIfIndex,
dot1agCfmMepPrimaryVid, tmnxDot1agCfmMepSdpId, tmnxDot1agCfmMepVcId,
or tmnxDot1agCfmMepSvcId is non-zero. When this object is applicable
(non-zero), the above objects MUST be set to zero (0).
Once set, this object can not be modified."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 25 }
tmnxDot1agCfmMepFacilityVlanId OBJECT-TYPE
SYNTAX VlanIdOrNone
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFacilityVlanId specifies, along with
tmnxDot1agCfmMepFacilityIfIndex and tmnxDot1agCfmMepFacilityType, the
encapsulation value of the port or interface associated with this MEP.
The tmnxDot1agCfmMepFacilityVlanId is applicable to facility MEPs
only, and MUST be set to zero (0) when dot1agCfmMepIfIndex,
dot1agCfmMepPrimaryVid, tmnxDot1agCfmMepSdpId, tmnxDot1agCfmMepVcId,
or tmnxDot1agCfmMepSvcId is non-zero. When this object is applicable
(non-zero), the above objects MUST be set to zero (0).
Once set, this object can not be modified."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 26 }
tmnxDot1agCfmMepFacilityType OBJECT-TYPE
SYNTAX INTEGER {
nonFacilityType (0),
port (1),
interface (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFacilityType specifies, along with
tmnxDot1agCfmMepFacilityIfIndex and tmnxDot1agCfmMepFacilityVlanId,
whether the port or interface is associated with this MEP.
The tmnxDot1agCfmMepFacilityType is applicable to facility MEPs only,
and MUST be set to 'nonFacilityType (0)' when dot1agCfmMepIfIndex,
dot1agCfmMepPrimaryVid, tmnxDot1agCfmMepSdpId, tmnxDot1agCfmMepVcId,
or tmnxDot1agCfmMepSvcId is non-zero. When this object is applicable
(non-zero), the above objects MUST be set to zero (0).
Once set, this object can not be modified."
DEFVAL { nonFacilityType }
::= { tmnxDot1agCfmMepEntry 27 }
tmnxDot1agCfmMepFcltyFaultNotify OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFcltyFaultNotify specifies whether or not
a fault detected on this Facility MEP will notify the port or facility
tunnel associated to this MEP.
This object pertains to Facility MEPs only. Attempting to change this
object away from its default for a non-facility MEP will result in an
'inconsistentValue' error."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 28 }
tmnxDot1agCfmMepDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepDescription specifies a user supplied
detailed description for this ETH-CFM MEP."
DEFVAL { "" }
::= { tmnxDot1agCfmMepEntry 29 }
tmnxDot1agCfmMepMcLagInactive OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (0),
standby (1),
active (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepMcLagInactive indicates whether or not the
MEP is inactive, 'standby (2)', due to the MC-LAG standby state. The
value of tmnxDot1agCfmMcLagStdbyInactive must be set to 'true (1)' for
this object to have meaning and return anything other than
'notApplicable (0)'."
::= { tmnxDot1agCfmMepEntry 30 }
tmnxDot1agCfmMepCcmPaddingSize OBJECT-TYPE
SYNTAX Unsigned32 (0 | 3..1500)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCcmPaddingSize specifies the number of
additional octets inserted into the CCM PDU for the Data TLV padding.
If tmnxDot1agCfmMepCcmPaddingSize is set to zero (0), no Data TLV will
be added to the CCM PDUs."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 31 }
tmnxDot1agCfmMepCcmIgnoreTLVs OBJECT-TYPE
SYNTAX BITS {
interfaceStatus (0),
portStatus (1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCcmIgnoreTLVs specifies the set of TLVs
that are received in a CCM PDU for the Remote MEP state machine of the
MEP that will be validated for format correctness but their values
will be ignored and marked 'Absent' by ETH-CFM."
DEFVAL { {} }
::= { tmnxDot1agCfmMepEntry 32 }
tmnxDot1agCfmMepCsfEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCsfEnable specifies whether received CSF
(Client Signal Fault) frames are processed by the Maintenance Entity
Group (MEG)."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 33 }
tmnxDot1agCfmMepCsfRxMultiplier OBJECT-TYPE
SYNTAX Unsigned32 (0 | 20..300)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCsfRxMultiplier specifies the receive
period multiplier used for timing out CSF, in increments of 5.
To calculate the timeout period of CSF frames the following formula is
used:
(CSF-rx-interval X multiplier) / 10
The default multiplier, therefore, is 3.5 times the interval."
DEFVAL { 35 }
::= { tmnxDot1agCfmMepEntry 34 }
tmnxDot1agCfmMepCsfRxState OBJECT-TYPE
SYNTAX INTEGER {
los (0),
ais (1),
rdi (2),
dci (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCsfRxState indicates the state of the
received CSF frames for the MEP.
The values are:
los (0) - Client Loss of Signal
ais (1) - Client Forward Defect Indication
rdi (2) - Client Reverse Defect Indication
dci (3) - Client Defect Clear Indication"
DEFVAL { dci }
::= { tmnxDot1agCfmMepEntry 35 }
tmnxDot1agCfmMepCsfRxInterval OBJECT-TYPE
SYNTAX Unsigned32 (1 | 60)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCsfRxInterval indicates the CSF Interval
received in the most recent CSF frame."
DEFVAL { 1 }
::= { tmnxDot1agCfmMepEntry 36 }
tmnxDot1agCfmMepCsfRxCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCsfRxCount indicates the number of CSF
frames received on the MEP since the time CSF was enabled."
::= { tmnxDot1agCfmMepEntry 37 }
tmnxDot1agCfmMepEthAisTxFail OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthAisTxFail indicates the number of AIS
frames the MEP failed to transmit due to resource limitations."
::= { tmnxDot1agCfmMepEntry 38 }
tmnxDot1agCfmMepTxLbmTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTxLbmTimeout specifies the duration, in
seconds, before a loopback PDU sent by the node is considered to be
timed out."
DEFVAL { 5 }
::= { tmnxDot1agCfmMepEntry 39 }
tmnxDot1agCfmMepTxLbmInterval OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..600)
UNITS "deciseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTxLbmInterval specifies the duration,
in deciseconds, between loopback PDU transmissions. A value of zero
is only valid if there are 5 or fewer loopbacks in the test (as defined
by dot1agCfmMepTransmitLbmMessages)."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 40 }
tmnxDot1agCfmMepLbmPaddingSize OBJECT-TYPE
SYNTAX Unsigned32 (0 | 3..9778)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepLbmPaddingSize specifies the number of
additional octets inserted into the LBM PDU for the Data TLV padding.
If tmnxDot1agCfmMepLbmPaddingSize is set to zero (0), no Data TLV will
be added to the LBM PDUs. Note that setting this value is mutually
exclusive with setting dot1agCfmMepTransmitLbmDataTlv."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 41 }
tmnxDot1agCfmMepIfSupportEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepIfSupportEnable specifies whether or not
the MEP will generate AIS PDUs when the endpoint associated to this
MEP is down regardless of CCM failures."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 42 }
tmnxDot1agCfmMepAisLowPrioDef OBJECT-TYPE
SYNTAX Dot1agCfmLowestAlarmPri
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepAisLowPrioDef specifies the lowest
priority defect that is allowed to generate an AIS frame.
When this object is 'allDef (1)', AIS frame generation will be
triggered for any defect in the CCM state machine.
When this object is 'macRemErrXcon (2)', AIS frame generation will be
triggered for defMACstatus defect and any defect higher than
defMACstatus."
DEFVAL { allDef }
::= { tmnxDot1agCfmMepEntry 43 }
tmnxDot1agCfmMepCollectLmmStats OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCollectLmmStats specifies whether or not
to compute the Y.1731 Ethernet Loss Measurement (ETH-LM) RxFCl and
TxFCl service frame counters for the specified MEP. Note that when
tmnxDot1agCfmMepCollectLmmStats is set to 'true', all data traffic
regardless of forwarding class level, both in and out of profile, will
be aggregated to a single stat counter.
Configuration of tmnxDot1agCfmMepCollectLmmStats is mutually exclusive
with the forwarding class level aware objects
tmnxDot1agCfmMepCollLmmFcSts and tmnxDot1agCfmMepCollLmmFcStsInP.
The RxFCl and TxFCl counters are used by ETH-LM tests. An ETH-LM test
is created using TIMETRA-OAM-PM-MIB::tmnxOamPmCfgLossLmmRowStatus."
REFERENCE
"ITU-T G.8013/Y.1731, 'OAM functions and mechanisms for Ethernet based
networks', 11/2013, Section 8.1 'Frame loss measurement (ETH-LM)'."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 44 }
tmnxDot1agCfmMepCreationOrigin OBJECT-TYPE
SYNTAX TmnxCreateOrigin
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCreationOrigin indicates the mechanism
which created this entry."
::= { tmnxDot1agCfmMepEntry 45 }
tmnxDot1agCfmMepEthTestTargMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthTestTargMepId specifies the
Maintenance association End Point Identifier (MepId) of another MEP in
the same Maintenance Association that the Eth-Test frames will be sent
to. If the tmnxDot1agCfmMepEthTestTargMepId is set then a local lookup
for the target MEP destination MAC address will be performed when the
test is started. Note that a valid target destination MAC address must
be found for proper execution of the Eth test if the
tmnxDot1agCfmMepEthTestTargMepId is being used as the input for the
test. The tmnxDot1agCfmMepEthTestTargMepId cannot be set if the
tmnxDot1agCfmMepEthTestMacAddr is set to a non-zero value.
Setting this object will trigger the test frame to be sent. Once the
test is complete, the object will revert to the default value,
indicating that another test is possible."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 46 }
tmnxDot1agCfmMepEthTestLstDstMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthTestLstDstMac indicates the
destination MAC address used in the most recent Eth-Test. If there
is no information about a previous test run, or if the test was not
able to be initiated properly, tmnxDot1agCfmMepEthTestLstDstMac will
have a value of all zeros. If the Eth-Test was initiated properly,
then the unicast MAC address that was used as the destination for the
most recent test PDU will be stored in
tmnxDot1agCfmMepEthTestLstDstMac."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepEntry 47 }
tmnxDot1agCfmMepOWDTTargetMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepOWDTTargetMepId specifies the Maintenance
association End Point Identifier (MepId) of another MEP in the same
Maintenance Association that the One-Way-Delay Test frames will be
sent to. If the tmnxDot1agCfmMepOWDTTargetMepId is set then a local
lookup for the target MEP destination MAC address will be performed
when the test is started. Note that a valid target destination MAC
address must be found for proper execution of the one-way-delay-test
if the tmnxDot1agCfmMepOWDTTargetMepId is being used as the input for
the test. The tmnxDot1agCfmMepOWDTTargetMepId cannot be set if the
tmnxDot1agCfmMepOWDTMacAddress is set to a non-zero value.
Setting this object will trigger the test frame to be sent. Once the
test is complete, the object will revert to the default value,
indicating that another test is possible."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 48 }
tmnxDot1agCfmMepOWDTLstDstMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepOWDTLstDstMac indicates the
destination MAC addressed used in the most recent One-Way-Delay Test.
If there is no information about a previous test run, or if the test
was not able to be initiated properly, tmnxDot1agCfmMepOWDTLstDstMac
will have a value of all zeros. If the One-Way-Delay Test was
initiated properly, then the unicast MAC address that was used as the
destination for the most recent test PDU will be stored in
tmnxDot1agCfmMepOWDTLstDstMac."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepEntry 49 }
tmnxDot1agCfmMepTWDTTargetMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTWDTTargetMepId specifies the Maintenance
association End Point Identifier (MepId) of another MEP in the same
Maintenance Association that the Two-Way-Delay Test frames will be
sent to. If the tmnxDot1agCfmMepTWDTTargetMepId is set then a local
lookup for the target MEP destination MAC address will be performed
when the test is started. Note that a valid target destination MAC
address must be found for proper execution of the two-way-delay-test
if the tmnxDot1agCfmMepTWDTTargetMepId is being used as the input for
the test. The tmnxDot1agCfmMepTWDTTargetMepId cannot be set if the
tmnxDot1agCfmMepTWDTMacAddress is set to a non-zero value.
Setting this object will trigger the test frame to be sent. Once the
test is complete, the object will revert to the default value,
indicating that another test is possible."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 50 }
tmnxDot1agCfmMepTWDTLstDstMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTWDTLstDstMac indicates the
destination MAC addressed used in the most recent Two-Way-Delay Test.
If there is no information about a previous test run, or if the test
was not able to be initiated properly, tmnxDot1agCfmMepTWDTLstDstMac
will have a value of all zeros. If the Two-Way-Delay Test was
initiated properly, then the unicast MAC address that was used as the
destination for the most recent test PDU will be stored in
tmnxDot1agCfmMepTWDTLstDstMac."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepEntry 51 }
tmnxDot1agCfmMepCollLmmFcSts OBJECT-TYPE
SYNTAX TFCSet
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCollLmmFcSts specifies which forwarding
class levels (in and out of profile combined) have enabled the
computation for Y.1731 Ethernet Loss Measurement (ETH-LM) RxFCl and
TxFCl service frame counters for the specified MEP. If the bit
corresponding to a forwarding class level is set, then a unique
counter will be used to track all the combined in and out of profile
traffic associated with that forwarding class.
Note that no tmnxDot1agCfmMepCollLmmFcSts bits can be set if
tmnxDot1agCfmMepCollectLmmStats is set to 'true' as the two are
mutually exclusive.
The RxFCl and TxFCl counters are used by ETH-LM tests. An ETH-LM test
is created using TIMETRA-OAM-PM-MIB::tmnxOamPmCfgLossLmmRowStatus."
REFERENCE
"ITU-T G.8013/Y.1731, 'OAM functions and mechanisms for Ethernet based
networks', 11/2013, Section 8.1 'Frame loss measurement (ETH-LM)'."
DEFVAL { {} }
::= { tmnxDot1agCfmMepEntry 52 }
tmnxDot1agCfmMepCollLmmFcStsInP OBJECT-TYPE
SYNTAX TFCSet
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCollLmmFcStsInP specifies which
forwarding class levels (in profile only) have enabled the computation
for Y.1731 Ethernet Loss Measurement (ETH-LM) RxFCl and TxFCl service
frame counters for the specified MEP. If the bit corresponding to a
forwarding class level is set, then a unique counter will be used to
track only all the in profile data traffic that is associated with
that forwarding class.
Note that no tmnxDot1agCfmMepCollLmmFcStsInP bits can be set if
tmnxDot1agCfmMepCollectLmmStats is set to 'true' as the two are
mutually exclusive.
The RxFCl and TxFCl counters are used by ETH-LM tests. An ETH-LM test
is created using TIMETRA-OAM-PM-MIB::tmnxOamPmCfgLossLmmRowStatus."
REFERENCE
"ITU-T G.8013/Y.1731, 'OAM functions and mechanisms for Ethernet based
networks', 11/2013, Section 8.1 'Frame loss measurement (ETH-LM)'."
DEFVAL { {} }
::= { tmnxDot1agCfmMepEntry 53 }
tmnxDot1agCfmMepTxEthVsmGrace OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTxEthVsmGrace specifies whether or not
Vendor Specific Message (VSM) grace period notifications will be sent
to the ETH-CFM remote MEP peers of this local MEP. The value 'true
(1)' enables grace period notifications, and the value 'false (2)'
suppresses the notifications.
During an outage, the modification of this object from 'true (1)' to
'false (2)' will cause an immediate clear of all grace period
notifications, after which no further notifications will be sent. A
modification of this object from 'false (2)' to 'true (1)' will not
enable the transmission of VSM grace period for any outages currently
in progress but will take effect for subsequent outages.
Note that this value is mutually exclusive to tmnxDot1agCfmMepTxEthEd,
and only one of the two can be enabled at any time."
DEFVAL { true }
::= { tmnxDot1agCfmMepEntry 54 }
tmnxDot1agCfmMepRxEthVsmGrace OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepRxEthVsmGrace specifies whether or not
VSM grace period notifications that are received on the local MEP
will be processed. The value 'true (1)' enables grace period
notification processing, and the value 'false (2)' disables
processing and causes any received VSM grace period notifications to
be ignored."
DEFVAL { true }
::= { tmnxDot1agCfmMepEntry 55 }
tmnxDot1agCfmMepTxEthEd OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTxEthEd specifies whether or not Ethernet
Expect Defect (ETH-ED) PDUs will be sent to the ETH-CFM remote MEP
peers of this local MEP. The value 'true (1)' enables ETH-ED PDU
transmission, and the value 'false (2)' suppresses transmissions.
During an outage, the modification of this object from 'true (1)' to
'false (2)' will cause an immediate clear of the ETH-ED PDU
transmission state, after which no further notifications will be sent.
A modification of this object from 'false (2)' to 'true (1)' will not
enable the transmission of ETH-ED for any outages currently in
progress, but will take effect for subsequent outages.
Note that this value is mutually exclusive to
tmnxDot1agCfmMepTxEthVsmGrace, and only one of the two can be enabled
at any time."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 56 }
tmnxDot1agCfmMepRxEthEd OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepRxEthEd specifies whether or not ETH-ED
PDUs that are received on the local MEP will be processed. The value
'true (1)' enables ETH-ED PDU processing, and the value 'false (2)'
disables processing and causes received MCC-ED notifications to be
ignored."
DEFVAL { true }
::= { tmnxDot1agCfmMepEntry 57 }
tmnxDot1agCfmMepEthEdMaxDurRx OBJECT-TYPE
SYNTAX Unsigned32 (0..86400)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthEdMaxDurRx specifies the maximum
Expected Duration value, in seconds, that will be used to track a peer
MEP outage. This value limits the size of the received ETH-ED expected
defect window to the lesser of the received value from the peer, or
the value of tmnxDot1agCfmMepEthEdMaxDurRx. A value of zero (0)
specifies that the received defect window advertised by the peer will
be used."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepEntry 58 }
tmnxDot1agCfmMepEthEdPriority OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthEdPriority specifies the priority
value for ETH-ED PDUs transmitted by the MEP.
If this object has the value '-1', the priority of this entry is
deferred to the dot1agCfmMepCcmLtmPriority associated with this MEP."
DEFVAL { -1 }
::= { tmnxDot1agCfmMepEntry 59 }
tmnxDot1agCfmMepLbmSvcActResp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepLbmSvcActResp specifies whether or not
the MEP is capable of processing service activation streams
encapsulated in the ETH-CFM request Loopback Message (LBM).
When the value of this object is 'true (1)', additional resources will
be allocated to allow the MEP to respond to high bandwidth requests,
which are typically service activation requests, encapsulated in the
ETH-LBM format. While this object is 'true (1)' the MEP will not
validate any type-length-value (TLV)s and will not increment or
compute any loopback statistics.
When this object is 'false (2)', the MEP LBMs are reverted to standard
processing."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 60 }
tmnxDot1agCfmMepEthBnReceive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnReceive specifies whether or not the
reception and processing of Eth-BN (Ethernet Bandwidth Notification)
PDUs is enabled.
The value 'true (1)' specifies that the reception and processing is
enabled."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 61 }
tmnxDot1agCfmMepEthBnRxUpdPacing OBJECT-TYPE
SYNTAX Unsigned32 (1..600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnRxUpdPacing specifies the pacing of
the messages from the Eth-CFM subsystem to the QoS subsystem. The
updates will be held by the Eth-CFM subsystem, but the sending of the
most recent update will be held until the expiration of the pacing
timer."
DEFVAL { 5 }
::= { tmnxDot1agCfmMepEntry 62 }
tmnxDot1agCfmMepInstallMep OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepInstallMep specifies whether or not the
MEP is installed in the forwarding plane and runs any of the Eth-CFM
State Machines.
When the value of this object is set to 'true (1)', the administrative
state of the MEP can be enabled.
When the value of this object is 'false (2)', the MEP will not
terminate ETH-CFM PDUs at any level in any direction. In addition, the
MEPs administative state must also be disabled.
The MEP must be administratively down in order to change the value of
this object."
DEFVAL { false }
::= { tmnxDot1agCfmMepEntry 63 }
tmnxDot1agCfmMepEthTestRsltTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepEthTestRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepEthTestRsltTable indicates the results of all
eth-tests indexed by the originating MAC addresses.
This table is not persistent over reboots of the chassis."
::= { tmnxDot1agCfmMep 2 }
tmnxDot1agCfmMepEthTestRsltEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepEthTestRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEG result table."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
tmnxDot1agCfmMepSrcMacAddress
}
::= { tmnxDot1agCfmMepEthTestRsltTable 1 }
TmnxDot1agCfmMepEthTestRsltEntry ::= SEQUENCE
{
tmnxDot1agCfmMepSrcMacAddress MacAddress,
tmnxDot1agCfmMepFrameCount Counter32,
tmnxDot1agCfmMepByteCount Counter32,
tmnxDot1agCfmMepFailedBits Counter32,
tmnxDot1agCfmMepCrcFailures Counter32,
tmnxDot1agCfmMepCurrByteCount Gauge32,
tmnxDot1agCfmMepCurrFailedBits Gauge32,
tmnxDot1agCfmMepCurrCrcFailures TruthValue
}
tmnxDot1agCfmMepSrcMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSrcMacAddress indicates the MAC address
of the issuer of the eth-test."
::= { tmnxDot1agCfmMepEthTestRsltEntry 1 }
tmnxDot1agCfmMepFrameCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFrameCount indicates the number of frames
received from the issuer of the eth-test."
::= { tmnxDot1agCfmMepEthTestRsltEntry 2 }
tmnxDot1agCfmMepByteCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepByteCount indicates the number of bytes
received from the issuer of the eth-test."
::= { tmnxDot1agCfmMepEthTestRsltEntry 3 }
tmnxDot1agCfmMepFailedBits OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFailedBits indicates the accumulated
number of bits that did not match the test pattern in all received
Eth-Tst frames since tmnxDot1agCfmMepEthTestEnable is configured from
'false' to 'true'."
::= { tmnxDot1agCfmMepEthTestRsltEntry 4 }
tmnxDot1agCfmMepCrcFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCrcFailures indicates the accumulated
number of CRC checksum failures."
::= { tmnxDot1agCfmMepEthTestRsltEntry 5 }
tmnxDot1agCfmMepCurrByteCount OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCurrByteCount indicates the number of
bytes contained in the most recently received Eth-Tst frame Test TLV."
::= { tmnxDot1agCfmMepEthTestRsltEntry 6 }
tmnxDot1agCfmMepCurrFailedBits OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCurrFailedBits indicates the number of
bits that did not match the test pattern in the most recently received
Eth-Tst frame."
::= { tmnxDot1agCfmMepEthTestRsltEntry 7 }
tmnxDot1agCfmMepCurrCrcFailures OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCurrCrcFailures indicates that CRC errors
were detected in the most recently received Eth-Tst frame."
::= { tmnxDot1agCfmMepEthTestRsltEntry 8 }
tmnxDot1agCfmMepDelayRsltTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepDelayRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepDelayRsltTable indicates the results of all the
One-Way/Two-Way Delay Tests from the originating MAC addresses.
This table is not persistent over reboots of the chassis."
::= { tmnxDot1agCfmMep 3 }
tmnxDot1agCfmMepDelayRsltEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepDelayRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEG result table."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
tmnxDot1agCfmMepDelaySrcMacAddr,
tmnxDot1agCfmMepDelayTestType
}
::= { tmnxDot1agCfmMepDelayRsltTable 1 }
TmnxDot1agCfmMepDelayRsltEntry ::= SEQUENCE
{
tmnxDot1agCfmMepDelaySrcMacAddr MacAddress,
tmnxDot1agCfmMepDelayTestType INTEGER,
tmnxDot1agCfmMepDelayTestDelay Integer32,
tmnxDot1agCfmMepDelayVariation Unsigned32
}
tmnxDot1agCfmMepDelaySrcMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepDelaySrcMacAddr indicates the source MAC
address of the issuer of the test."
::= { tmnxDot1agCfmMepDelayRsltEntry 1 }
tmnxDot1agCfmMepDelayTestType OBJECT-TYPE
SYNTAX INTEGER {
oneWayTest (1),
twoWayTest (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepDelayTestType indicates the type of test
this row details."
::= { tmnxDot1agCfmMepDelayRsltEntry 2 }
tmnxDot1agCfmMepDelayTestDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepDelayTestDelay indicates the amount of
time, measured in microseconds, from when the test-frame was
transmitted to the time it was received minus the local processing
time taken by the remote system."
::= { tmnxDot1agCfmMepDelayRsltEntry 3 }
tmnxDot1agCfmMepDelayVariation OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepDelayVariation indicates the amount of
time delay variation, measured in microseconds, from the two most
recent time delay measurements"
::= { tmnxDot1agCfmMepDelayRsltEntry 4 }
tmnxDot1agCfmMepSlmTWTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepSlmTWTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepSlmTWTestTable consists of the MEP configuration for
issuing individual Synthetic Loss Measurement tests."
REFERENCE
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tmnxDot1agCfmMep 4 }
tmnxDot1agCfmMepSlmTWTestEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepSlmTWTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepSlmTWTestEntry contains the configuration for
generating Synthetic Loss Measurement (SLM) Tests for a particular
MEP. A row exists for each row in the dot1agCfmMepTable, and is
destroyed automatically with the removal of a row in the
dot1agCfmMepTable.
Results from a two-way SLM test are reported in
tmnxDot1agCfmMepSlmTestRsltTable with the tmnxDot1agCfmMepSlmTestType
set to 'twoWayTest (2)'."
AUGMENTS { dot1agCfmMepEntry }
::= { tmnxDot1agCfmMepSlmTWTestTable 1 }
TmnxDot1agCfmMepSlmTWTestEntry ::= SEQUENCE
{
tmnxDot1agCfmMepSlmTWTestStatus TmnxEnabledDisabled,
tmnxDot1agCfmMepSlmTWTestId Unsigned32,
tmnxDot1agCfmMepSlmTWMacAddress MacAddress,
tmnxDot1agCfmMepSlmTWPriority Unsigned32,
tmnxDot1agCfmMepSlmTWInterval Unsigned32,
tmnxDot1agCfmMepSlmTWTimeout Unsigned32,
tmnxDot1agCfmMepSlmTWDataSize Unsigned32,
tmnxDot1agCfmMepSlmTWSendCount Unsigned32,
tmnxDot1agCfmMepSlmTWIntrvlUnits INTEGER,
tmnxDot1agCfmMepSlmTWTargetMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmMepSlmTWLstDstMac MacAddress
}
tmnxDot1agCfmMepSlmTWTestStatus OBJECT-TYPE
SYNTAX TmnxEnabledDisabled
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWTestStatus specifies the operational
state of the two-way Synthetic Loss Measurement (SLM) test.
To issue a two-way SLM test the user must issue an SNMP SET on this
object with a value 'enabled (1)'. To abort the two-way SLM test issue
an SNMP SET on this object with the value 'disabled (2)'.
A read on this object represents the current state of the two-way SLM
test:
enabled (1) - The test is actively running, and attempts at
modifying any two-way SLM object will be rejected
disabled (2) - The test is not running.
Once the test is complete this object will revert to the default value
'disabled (2)'."
DEFVAL { disabled }
::= { tmnxDot1agCfmMepSlmTWTestEntry 1 }
tmnxDot1agCfmMepSlmTWTestId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWTestId indicates the test identifier
used to initiate the two-way Synthetic Loss Measurement (SLM) test."
::= { tmnxDot1agCfmMepSlmTWTestEntry 2 }
tmnxDot1agCfmMepSlmTWMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWMacAddress specifies the MAC address
used as a target for the two-way Synthetic Loss Measurement (SLM)
test.
This object MUST be set to a valid MAC Address for proper execution of
the two-way SLM test if tmnxDot1agCfmMepSlmTWTargetMepId is set to
zero (0)."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepSlmTWTestEntry 3 }
tmnxDot1agCfmMepSlmTWPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWPriority specifies the priority used
in the generated test frame for the two-way Synthetic Loss Measurement
(SLM) test."
DEFVAL { 7 }
::= { tmnxDot1agCfmMepSlmTWTestEntry 4 }
tmnxDot1agCfmMepSlmTWInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..90)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWInterval, in conjunction with
tmnxDot1agCfmMepSlmTWIntrvlUnits, specifies the interval between
Synthetic Loss Measurement (SLM) messages sent by the two-way SLM
test. For example, if tmnxDot1agCfmMepSlmTWInterval has the value 90,
and tmnxDot1agCfmMepSlmTWIntrvlUnits has the value 'centiseconds(2)',
the interval between SLM messages is 0.9 seconds.
The tmnxDot1agCfmMepSlmTWInterval and tmnxDot1agCfmMepSlmTWIntrvlUnits
pair provide support for the following intervals:
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 seconds;
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 seconds."
DEFVAL { 5 }
::= { tmnxDot1agCfmMepSlmTWTestEntry 5 }
tmnxDot1agCfmMepSlmTWTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWTimeout specifies the timeout value,
in seconds, to wait for a Synthetic Loss Measurement (SLM) message to
reply for the two-way SLM test. Upon expiration of the timeout period,
the agent assumes that the message response will not be received. Any
response received after the timeout period has expired is silently
discarded."
DEFVAL { 5 }
::= { tmnxDot1agCfmMepSlmTWTestEntry 6 }
tmnxDot1agCfmMepSlmTWDataSize OBJECT-TYPE
SYNTAX Unsigned32 (0..1500)
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWDataSize specifies the data size, in
bytes, contained in the padding TLV for the two-way Synthetic Loss
Measurement (SLM) test. A value of zero (0) specifies that no padding
TLV is inserted in the SLM packet. Any non-zero value will increase
the packet size by the specified data size plus 3 bytes for the TLV
header."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepSlmTWTestEntry 7 }
tmnxDot1agCfmMepSlmTWSendCount OBJECT-TYPE
SYNTAX Unsigned32 (1..1000)
UNITS "packets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWSendCount specifies the number of
Synthetic Loss Measurement (SLM) packets to send during the two-way
SLM test."
DEFVAL { 1 }
::= { tmnxDot1agCfmMepSlmTWTestEntry 8 }
tmnxDot1agCfmMepSlmTWIntrvlUnits OBJECT-TYPE
SYNTAX INTEGER {
seconds (1),
centiseconds (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWIntrvlUnits, in conjunction with
tmnxDot1agCfmMepSlmTWInterval, specifies the interval between Synthetic
Loss Measurement (SLM) messages sent by the two-way SLM test. For
example, if tmnxDot1agCfmMepSlmTWInterval has the value 90, and
tmnxDot1agCfmMepSlmTWIntrvlUnits has the value 'centiseconds(2)', the
interval between SLM messages is 0.9 seconds.
The intervals supported are shown in the tmnxDot1agCfmMepSlmTWInterval
DESCRIPTION clause."
DEFVAL { seconds }
::= { tmnxDot1agCfmMepSlmTWTestEntry 9 }
tmnxDot1agCfmMepSlmTWTargetMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWTargetMepId specifies the
Maintenance association End Point Identifier (MepId) of another MEP
in the same Maintenance Association that the Synthetic Loss
Measurement (SLM) messages should be directed to. If the
tmnxDot1agCfmMepSlmTWTargetMepId is set then a local lookup for the
target MEP destination MAC address will be performed when the test is
started. Note that a valid target destination MAC address must be
found for proper execution of the two-way SLM test if the
tmnxDot1agCfmMepSlmTWTargetMepId is being used as the input for the
test. The tmnxDot1agCfmMepSlmTWTargetMepId cannot be set if the
tmnxDot1agCfmMepSlmTWMacAddress is set to a non-zero value."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepSlmTWTestEntry 10 }
tmnxDot1agCfmMepSlmTWLstDstMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTWLstDstMac indicates the
destination MAC addressed used in the most recent two-way SLM Test.
If there is no information about a previous test run, or if the test
was not able to be initiated properly, tmnxDot1agCfmMepSlmTWLstDstMac
will have a value of all zeros. If the two-way SLM Test was initiated
properly, then the unicast MAC address that was used as the
destination for the most recent test PDU will be stored in
tmnxDot1agCfmMepSlmTWLstDstMac."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepSlmTWTestEntry 11 }
tmnxDot1agCfmMepSlmOWTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepSlmOWTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepSlmOWTestTable consists of the MEP configuration for
issuing individual Synthetic Loss Measurement one-way tests."
REFERENCE
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tmnxDot1agCfmMep 5 }
tmnxDot1agCfmMepSlmOWTestEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepSlmOWTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepSlmOWTestEntry contains the configuration for
generating Synthetic Loss Measurement (SLM) Tests for a particular
MEP. A row exists for each row in the dot1agCfmMepTable, and is
destroyed automatically with the removal of a row in the
dot1agCfmMepTable.
Results from a one-way SLM test are reported in
tmnxDot1agCfmMepSlmTestRsltTable with tmnxDot1agCfmMepSlmTestType set
to 'oneWayTest (1)'."
AUGMENTS { dot1agCfmMepEntry }
::= { tmnxDot1agCfmMepSlmOWTestTable 1 }
TmnxDot1agCfmMepSlmOWTestEntry ::= SEQUENCE
{
tmnxDot1agCfmMepSlmOWTestStatus TmnxEnabledDisabled,
tmnxDot1agCfmMepSlmOWTestId Unsigned32,
tmnxDot1agCfmMepSlmOWMacAddress MacAddress,
tmnxDot1agCfmMepSlmOWPriority Unsigned32,
tmnxDot1agCfmMepSlmOWInterval Unsigned32,
tmnxDot1agCfmMepSlmOWDataSize Unsigned32,
tmnxDot1agCfmMepSlmOWSendCount Unsigned32,
tmnxDot1agCfmMepSlmOWTargetMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmMepSlmOWLstDstMac MacAddress
}
tmnxDot1agCfmMepSlmOWTestStatus OBJECT-TYPE
SYNTAX TmnxEnabledDisabled
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWTestStatus specifies the operational
state of the one-way Synthetic Loss Measurement (SLM) test.
To issue a one-way SLM test the user must issue an SNMP SET on this
object with a value 'enabled (1)'. To abort the one-way SLM test issue
an SNMP SET on this object with the value 'disabled (2)'.
A read on this object represents the current state of the one-way SLM
test:
enabled (1) - The test is actively running, and attempts at
modifying any one-way SLM object will be rejected
disabled (2) - The test is not running.
Once the test is complete this object will revert to the default value
'disabled (2)'."
DEFVAL { disabled }
::= { tmnxDot1agCfmMepSlmOWTestEntry 1 }
tmnxDot1agCfmMepSlmOWTestId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWTestId indicates the test identifier
used to initiate the one-way Synthetic Loss Measurement (SLM) test."
::= { tmnxDot1agCfmMepSlmOWTestEntry 2 }
tmnxDot1agCfmMepSlmOWMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWMacAddress specifies the MAC address
used as a target for the one-way Synthetic Loss Measurement (SLM)
Test.
This object MUST be set to a valid MAC Address for proper execution of
the one-way SLM test if tmnxDot1agCfmMepSlmOWTargetMepId is set to
zero (0)."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepSlmOWTestEntry 3 }
tmnxDot1agCfmMepSlmOWPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWPriority specifies the priority used
in the generated test frame for the one-way Synthetic Loss Measurement
(SLM) test."
DEFVAL { 7 }
::= { tmnxDot1agCfmMepSlmOWTestEntry 4 }
tmnxDot1agCfmMepSlmOWInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWInterval specifies the delay, in
seconds, between Synthetic Loss Measurement (SLM) messages for the
one-way SLM test."
DEFVAL { 5 }
::= { tmnxDot1agCfmMepSlmOWTestEntry 5 }
tmnxDot1agCfmMepSlmOWDataSize OBJECT-TYPE
SYNTAX Unsigned32 (0..1500)
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWDataSize specifies the data size, in
bytes, contained in the padding TLV for the one-way Synthetic Loss
Measurement (SLM) test. A value of zero (0) specifies that no padding
TLV is inserted in the SLM packet. Any non-zero value will increase
the packet size by the specified data size plus 3 bytes for the TLV
header."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepSlmOWTestEntry 6 }
tmnxDot1agCfmMepSlmOWSendCount OBJECT-TYPE
SYNTAX Unsigned32 (1..100)
UNITS "packets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWSendCount specifies the number of
Synthetic Loss Measurement (SLM) packets to send consecutively during
the one-way SLM test."
DEFVAL { 1 }
::= { tmnxDot1agCfmMepSlmOWTestEntry 7 }
tmnxDot1agCfmMepSlmOWTargetMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWTargetMepId specifies the
Maintenance association End Point Identifier (MepId) of another MEP
in the same Maintenance Association that the Synthetic Loss
Measurement (SLM) messages should be directed to. If the
tmnxDot1agCfmMepSlmOWTargetMepId is set then a local lookup for the
target MEP destination MAC address will be performed when the test is
started. Note that a valid target destination MAC address must be
found for proper execution of the one-way SLM test if the
tmnxDot1agCfmMepSlmOWTargetMepId is being used as the input for the
test. The tmnxDot1agCfmMepSlmOWTargetMepId cannot be set if the
tmnxDot1agCfmMepSlmOWMacAddress is set to a non-zero value."
DEFVAL { 0 }
::= { tmnxDot1agCfmMepSlmOWTestEntry 8 }
tmnxDot1agCfmMepSlmOWLstDstMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmOWLstDstMac indicates the
destination MAC addressed used in the most recent one-way SLM Test.
If there is no information about a previous test run, or if the test
was not able to be initiated properly, tmnxDot1agCfmMepSlmOWLstDstMac
will have a value of all zeros. If the one-way SLM Test was initiated
properly, then the unicast MAC address that was used as the
destination for the most recent test PDU will be stored in
tmnxDot1agCfmMepSlmOWLstDstMac."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmMepSlmOWTestEntry 9 }
tmnxDot1agCfmMepSlmTestRsltTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepSlmTestRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepSlmTestRsltTable consists of the results of manually
triggered Synthetic Loss Measurement tests."
::= { tmnxDot1agCfmMep 6 }
tmnxDot1agCfmMepSlmTestRsltEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepSlmTestRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepSlmTestRsltEntry contains the results of a manually
triggered Synthetic Loss Measurement (SLM) test for a particular MEP.
Rows are auto-generated by the system based on the issuing of a SLM
test."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
tmnxDot1agCfmMepSlmTestType,
tmnxDot1agCfmMepSlmRemoteMacAddr
}
::= { tmnxDot1agCfmMepSlmTestRsltTable 1 }
TmnxDot1agCfmMepSlmTestRsltEntry ::= SEQUENCE
{
tmnxDot1agCfmMepSlmTestType INTEGER,
tmnxDot1agCfmMepSlmRemoteMacAddr MacAddress,
tmnxDot1agCfmMepSlmTestId Unsigned32,
tmnxDot1agCfmMepSlmRemoteMepId Dot1agCfmMepIdOrZero,
tmnxDot1agCfmMepSlmLastTxSeqF Unsigned32,
tmnxDot1agCfmMepSlmPacketIn Counter32,
tmnxDot1agCfmMepSlmPacketLossIn Integer32,
tmnxDot1agCfmMepSlmPacketLossOut Integer32,
tmnxDot1agCfmMepSlmPacketUnack Gauge32
}
tmnxDot1agCfmMepSlmTestType OBJECT-TYPE
SYNTAX INTEGER {
oneWayTest (1),
twoWayTest (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTestType specifies whether the row for
this Synthetic Loss Measurement (SLM) test refers to a two-way SLM
test."
::= { tmnxDot1agCfmMepSlmTestRsltEntry 1 }
tmnxDot1agCfmMepSlmRemoteMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmRemoteMacAddr specifies the source MAC
address of the remote node involved in the test."
::= { tmnxDot1agCfmMepSlmTestRsltEntry 2 }
tmnxDot1agCfmMepSlmTestId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmTestId indicates the test identifier
that was used to initiate the Synthetic Loss Measurement (SLM) test."
::= { tmnxDot1agCfmMepSlmTestRsltEntry 3 }
tmnxDot1agCfmMepSlmRemoteMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmRemoteMepId indicates the MEP
Identifier of the remote node involved in the test.
Zero indicates that the remote node did not provide a MEP Identifier.
For example, zero is returned if the local node timed out while
waiting for a probe response for each probe sent for the test."
::= { tmnxDot1agCfmMepSlmTestRsltEntry 4 }
tmnxDot1agCfmMepSlmLastTxSeqF OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmLastTxSeqF indicates the last received
sequence number on the local node, transmitted by the remote node."
REFERENCE
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tmnxDot1agCfmMepSlmTestRsltEntry 5 }
tmnxDot1agCfmMepSlmPacketIn OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmPacketIn indicates the number of
packets received during the execution of the test."
REFERENCE
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tmnxDot1agCfmMepSlmTestRsltEntry 6 }
tmnxDot1agCfmMepSlmPacketLossIn OBJECT-TYPE
SYNTAX Integer32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmPacketLossIn indicates the number of
packets transmitted from the remote node but not received on the local
node during the execution of the test."
REFERENCE
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tmnxDot1agCfmMepSlmTestRsltEntry 7 }
tmnxDot1agCfmMepSlmPacketLossOut OBJECT-TYPE
SYNTAX Integer32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmPacketLossOut indicates the number of
packets transmitted from the local node but not received on the remote
node during the execution of the test."
REFERENCE
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tmnxDot1agCfmMepSlmTestRsltEntry 8 }
tmnxDot1agCfmMepSlmPacketUnack OBJECT-TYPE
SYNTAX Gauge32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepSlmPacketUnack indicates the number of
unacknowledged lost packets during the execution of the test."
REFERENCE
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
::= { tmnxDot1agCfmMepSlmTestRsltEntry 9 }
tmnxDot1agCfmMepMcstLbmRsltTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepMcstLbmRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepMcstLbmRsltTable consists of the results of manually
triggered ETH-CFM loopback tests where the value of
dot1agCfmMepTransmitLbmDestMacAddress was set to the multicast MAC
address for the MEP.
Only one result set per MEP is retained."
::= { tmnxDot1agCfmMep 7 }
tmnxDot1agCfmMepMcstLbmRsltEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepMcstLbmRsltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepMcstLbmRsltEntry contains an individual message
response to a manually triggered loopback test.
A row is auto-generated by the system upon receipt of a valid loopback
response that matches a multicast loopback test in progress."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
tmnxDot1agCfmMepLbmRemoteMepMac,
tmnxDot1agCfmMepLbmSeqNumber,
tmnxDot1agCfmMepLbmRxIndex
}
::= { tmnxDot1agCfmMepMcstLbmRsltTable 1 }
TmnxDot1agCfmMepMcstLbmRsltEntry ::= SEQUENCE
{
tmnxDot1agCfmMepLbmRemoteMepMac MacAddress,
tmnxDot1agCfmMepLbmSeqNumber Unsigned32,
tmnxDot1agCfmMepLbmRxIndex Unsigned32
}
tmnxDot1agCfmMepLbmRemoteMepMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepLbmRemoteMepMac specifies the MAC address
of the remote MEP responding to the multicast loopback message."
::= { tmnxDot1agCfmMepMcstLbmRsltEntry 1 }
tmnxDot1agCfmMepLbmSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepLbmSeqNumber specifies the sequence
number contained within the reply message."
::= { tmnxDot1agCfmMepMcstLbmRsltEntry 2 }
tmnxDot1agCfmMepLbmRxIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepLbmRxIndex indicates the order in which
the reply was received for the corresponding remote MAC address. It
is locally assigned and can be used to detect out of order responses."
::= { tmnxDot1agCfmMepMcstLbmRsltEntry 3 }
tmnxDot1agCfmMepDbTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepDbTable is an augmented table for the standard
IEEE8021-CFM table dot1agCfmMepDbTable."
::= { tmnxDot1agCfmMep 8 }
tmnxDot1agCfmMepDbEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepDbEntry is an augmented conceptual row in the
dot1agCfmMepDbTable. Objects defined in this row extend the
functionality of the base row.
Creation and deletion of rows in this table is managed through the
base table."
AUGMENTS { dot1agCfmMepDbEntry }
::= { tmnxDot1agCfmMepDbTable 1 }
TmnxDot1agCfmMepDbEntry ::= SEQUENCE
{
tmnxDot1agCfmMepDbGraceRx TruthValue,
tmnxDot1agCfmMepDbMccEdRx TruthValue
}
tmnxDot1agCfmMepDbGraceRx OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepDbGraceRx indicates whether the remote
peer is transmitting a grace period notification or not."
::= { tmnxDot1agCfmMepDbEntry 1 }
tmnxDot1agCfmMepDbMccEdRx OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepDbMccEdRx indicates whether the remote
peer is transmitting MCC-ED notifications or not."
::= { tmnxDot1agCfmMepDbEntry 2 }
tmnxDot1agCfmMepOpcodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepOpcodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmMepOpcodeTable consists of statistics that are kept in
the receive and transmit direction on a MEP for each CFM PDU Opcode."
REFERENCE
"Y.1731 clauses 8 and 9"
::= { tmnxDot1agCfmMep 9 }
tmnxDot1agCfmMepOpcodeEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepOpcodeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Mep Opcode Stats Table entry."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
tmnxDot1agCfmMepOpcode
}
::= { tmnxDot1agCfmMepOpcodeTable 1 }
TmnxDot1agCfmMepOpcodeEntry ::= SEQUENCE
{
tmnxDot1agCfmMepOpcode Dot1agCfmStatisticOpcodeName,
tmnxDot1agCfmMepOpcodeRx Counter32,
tmnxDot1agCfmMepOpcodeTx Counter32
}
tmnxDot1agCfmMepOpcode OBJECT-TYPE
SYNTAX Dot1agCfmStatisticOpcodeName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepOpcode specifies the CFM PDU Opcode to
which the statistics refer."
::= { tmnxDot1agCfmMepOpcodeEntry 1 }
tmnxDot1agCfmMepOpcodeRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of PDUs received on the MEP with the specified
Opcode."
::= { tmnxDot1agCfmMepOpcodeEntry 2 }
tmnxDot1agCfmMepOpcodeTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of PDUs transmitted from the MEP with the specified
Opcode."
::= { tmnxDot1agCfmMepOpcodeEntry 3 }
tmnxDot1agCfmMepExtOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMepExtOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEP Extended Operational Table augments the Maintenance
Association End Point (MEP) table of the IEEE8021-CFM-MIB,
dot1agCfmMepTable.
This table is a continuation from the Nokia SROS product series CFM
Mep table, tmnxDot1agCfmMepTable. It is intended for read-only
objects."
::= { tmnxDot1agCfmMep 10 }
tmnxDot1agCfmMepExtOpEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepExtOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row in the tmnxDot1agCfmMepExtOpTable. This row exists
only if the association dot1agCfmMepEntry is active."
AUGMENTS { dot1agCfmMepEntry }
::= { tmnxDot1agCfmMepExtOpTable 1 }
TmnxDot1agCfmMepExtOpEntry ::= SEQUENCE
{
tmnxDot1agCfmMepOpRxPeerGrace TruthValue,
tmnxDot1agCfmMepCcmTxRdi TruthValue,
tmnxDot1agCfmMepCcmTxPortStatus Dot1agCfmPortStatus,
tmnxDot1agCfmMepCcmTxIfStatus Dot1agCfmInterfaceStatus,
tmnxDot1agCfmMepTxAis INTEGER,
tmnxDot1agCfmMepTxGrace INTEGER,
tmnxDot1agCfmMepTxCcm INTEGER,
tmnxDot1agCfmMepEthBnNominalBw Integer32,
tmnxDot1agCfmMepEthBnCurrentBw Integer32,
tmnxDot1agCfmMepEthBnReportedBw Integer32,
tmnxDot1agCfmMepEthBnLastReport DateAndTime,
tmnxDot1agCfmMepEthBnUpdPacTimer TimeInterval,
tmnxDot1agCfmMepEthBnPortId Unsigned32,
tmnxDot1agCfmMepEthBnRxInterval Unsigned32
}
tmnxDot1agCfmMepOpRxPeerGrace OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepOpRxPeerGrace indicates whether the local
MEP is receiving and processing grace notifications from one or more
peer MEPs. A value of 'true (1)' indicates the local MEP is
receiving and processing grace from at least one peer MEP. A value
of 'false (2)' indicates that no peer grace notifications are being
received and processed."
DEFVAL { false }
::= { tmnxDot1agCfmMepExtOpEntry 1 }
tmnxDot1agCfmMepCcmTxRdi OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCcmTxRdi indicates whether or not the
Remote Defect Indication (RDI) bit was set on the most recent
Connectivity Check Message (CCM) transmission from the local MEP.
If the value of dot1agCfmMepActive or dot1agCfmMepCciEnabled is set to
'false (2)', or if the RDI bit was not set in the most recent
transmission, then tmnxDot1agCfmMepCcmTxRdi will return a value of
'false (2)'."
::= { tmnxDot1agCfmMepExtOpEntry 2 }
tmnxDot1agCfmMepCcmTxPortStatus OBJECT-TYPE
SYNTAX Dot1agCfmPortStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCcmTxPortStatus indicates the port status
TLV information included in the most recent Connectivity Check Message
(CCM) transmission from the local MEP.
If the value of dot1agCfmMepActive or dot1agCfmMepCciEnabled value is
set to 'false (2)', or if no port status TLV was included in the most
recent transmission, then tmnxDot1agCfmMepCcmTxPortStatus will return
a value of 'psNoPortStateTLV (0)'."
::= { tmnxDot1agCfmMepExtOpEntry 3 }
tmnxDot1agCfmMepCcmTxIfStatus OBJECT-TYPE
SYNTAX Dot1agCfmInterfaceStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepCcmTxIfStatus indicates the interface
status TLV information included in the most recent Connectivity Check
Message (CCM) transmission from the local MEP.
If the value of dot1agCfmMepActive or dot1agCfmMepCciEnabled value is
set to 'false (2)', or if no interface status TLV was included in the
most recent transmission, then tmnxDot1agCfmMepCcmTxIfStatus will
return a value of 'isNoInterfaceStatusTLV (0)'."
::= { tmnxDot1agCfmMepExtOpEntry 4 }
tmnxDot1agCfmMepTxAis OBJECT-TYPE
SYNTAX INTEGER {
noTransmit (0),
transmit (1),
pending (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTxAis indicates the state of the MEP AIS
PDU transmission.
Values:
noTransmit (0) - no AIS PDUs are being transmitted by the MEP
transmit (1) - MEP is currently transmitting AIS PDUs
pending (2) - MEP should be transmitting AIS PDUs but cannot due
to lack of resources or some other reason"
::= { tmnxDot1agCfmMepExtOpEntry 5 }
tmnxDot1agCfmMepTxGrace OBJECT-TYPE
SYNTAX INTEGER {
noTransmit (0),
grace (1),
ethEd (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTxGrace indicates the state of the MEP
grace period PDU transmission.
Values:
noTransmit (0) - no grace PDUs are being transmitted by the MEP
grace (1) - MEP is currently transmitting grace period PDUs
eth-ed (2) - MEP is currently transmitting Ethernet Expected
Defect (ETH-ED) PDUs"
::= { tmnxDot1agCfmMepExtOpEntry 6 }
tmnxDot1agCfmMepTxCcm OBJECT-TYPE
SYNTAX INTEGER {
noTransmit (0),
transmit (1),
suppressed (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepTxCcm indicates the state of the MEP CCM
PDU transmission.
Values:
noTransmit (0) - no CCM PDUs are being transmitted by the MEP
transmit (1) - MEP is currently transmitting CCM PDUs
suppressed (2) - MEP should be transmitting CCM PDUs but is suppressing
them due to an internal condition"
::= { tmnxDot1agCfmMepExtOpEntry 7 }
tmnxDot1agCfmMepEthBnNominalBw OBJECT-TYPE
SYNTAX Integer32
UNITS "megabps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnNominalBw indicates the data rate
received in the ETH-BN PDU. It is the nominal egress rate of the
physical port of the facility MEP.
A value of '-1' indicates that the rate value is not available."
::= { tmnxDot1agCfmMepExtOpEntry 8 }
tmnxDot1agCfmMepEthBnCurrentBw OBJECT-TYPE
SYNTAX Integer32
UNITS "megabps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnCurrentBw indicates the bandwidth of
the outdoor radio link. It is received in the ETH-BN PDU. The value
advises the physical port to change its egress rate.
A value of '-1' indicates that the rate value is not available."
::= { tmnxDot1agCfmMepExtOpEntry 9 }
tmnxDot1agCfmMepEthBnReportedBw OBJECT-TYPE
SYNTAX Integer32
UNITS "megabps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnReportedBw indicates the most recent
egress rate that the MEP reported to its port. The most recently
received current bandwidth in an ETH-BN message is marked as the
tmnxDot1agCfmMepEthBnReportedBw when the timer specified by
tmnxDot1agCfmMepEthBnRxUpdPacing expires.
A value of '-1' indicates that the rate value is not available."
::= { tmnxDot1agCfmMepExtOpEntry 10 }
tmnxDot1agCfmMepEthBnLastReport OBJECT-TYPE
SYNTAX DateAndTime (SIZE (11))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnLastReport indicates when the most
recent tmnxDot1agCfmMepEthBnReportedBw was sent to the MEP's port."
::= { tmnxDot1agCfmMepExtOpEntry 11 }
tmnxDot1agCfmMepEthBnUpdPacTimer OBJECT-TYPE
SYNTAX TimeInterval
UNITS "centiseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnUpdPacTimer indicates the time
interval, in centiseconds, until the next
tmnxDot1agCfmMepEthBnReportedBw value is sent to the MEP's port."
::= { tmnxDot1agCfmMepExtOpEntry 12 }
tmnxDot1agCfmMepEthBnPortId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnPortId indicates the port id
received in the ETH-BN PDU."
::= { tmnxDot1agCfmMepExtOpEntry 13 }
tmnxDot1agCfmMepEthBnRxInterval OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepEthBnRxInterval indicates the interval,
in seconds, between reception of ETH-BN PDUs."
::= { tmnxDot1agCfmMepExtOpEntry 14 }
tmnxDot1agCfmMip OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 8 }
tmnxDot1agCfmSapMipTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmSapMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the tmnxDot1agCfmSapMipTable indicates that the specified SAP
may have a MIP created on the endpoint."
::= { tmnxDot1agCfmMip 1 }
tmnxDot1agCfmSapMipEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmSapMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MIP (SAP) entry"
INDEX {
tmnxDot1agCfmSapMipIfIndex,
tmnxDot1agCfmSapMipVlanIdOrNone,
tmnxDot1agCfmSapMipPrimaryVlanId
}
::= { tmnxDot1agCfmSapMipTable 1 }
TmnxDot1agCfmSapMipEntry ::= SEQUENCE
{
tmnxDot1agCfmSapMipIfIndex InterfaceIndex,
tmnxDot1agCfmSapMipVlanIdOrNone Unsigned32,
tmnxDot1agCfmSapMipRowStatus RowStatus,
tmnxDot1agCfmSapMipSrcMacAddress MacAddress,
tmnxDot1agCfmSapMipPrimaryVlanId VlanIdOrNone
}
tmnxDot1agCfmSapMipIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Bridge Port or aggregated port
on which MEPs or MHFs might be configured."
::= { tmnxDot1agCfmSapMipEntry 1 }
tmnxDot1agCfmSapMipVlanIdOrNone OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"VLAN ID to which the MIP is attached, or 0, if none."
::= { tmnxDot1agCfmSapMipEntry 2 }
tmnxDot1agCfmSapMipRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The tmnxDot1agCfmSapMipRowStatus specifies the ability to enable MIP
creation under a SAP. Existing MIPs associated with the SAP may be
viewed via the tmnxDot1agCfmStackTable."
::= { tmnxDot1agCfmSapMipEntry 3 }
tmnxDot1agCfmSapMipSrcMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSapMipSrcMacAddress specifies the source MAC
address used by the MIP.
By default, the MAC address is the MAC address of the SAP."
::= { tmnxDot1agCfmSapMipEntry 4 }
tmnxDot1agCfmSapMipPrimaryVlanId OBJECT-TYPE
SYNTAX VlanIdOrNone
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSapMipPrimaryVlanId specifies primary VLAN
ID used by the MIP. A value of zero '(0)' specifies a non-primary vlan
MIP."
::= { tmnxDot1agCfmSapMipEntry 5 }
tmnxDot1agCfmSdpMipTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmSdpMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmSdpMipTable contains the configuration information for
Maintenance domain Intermediate Points (MIPs) associated with Service
Delivery Point (SDP) bindings and primary Virtual Local Area Networks
(VLANs)."
::= { tmnxDot1agCfmMip 2 }
tmnxDot1agCfmSdpMipEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmSdpMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"tmnxDot1agCfmSdpMipEntry contains configuration information for a MIP.
If the primary Virtual Local Area Network (VLAN) index of the row (i.e.
tmnxDot1agCfmSdpMipPrimaryVlanId) is zero, the MIP is configured
against an SDP binding. Otherwise, the MIP is configured against an
SDP binding and a Primary VLAN identifier.
Rows are created or destroyed using tmnxDot1agCfmSdpMipRowStatus."
INDEX {
tmnxDot1agCfmSdpMipSvcId,
tmnxDot1agCfmSdpMipSdpId,
tmnxDot1agCfmSdpMipVcId,
tmnxDot1agCfmSdpMipPrimaryVlanId
}
::= { tmnxDot1agCfmSdpMipTable 1 }
TmnxDot1agCfmSdpMipEntry ::= SEQUENCE
{
tmnxDot1agCfmSdpMipSvcId TmnxServId,
tmnxDot1agCfmSdpMipSdpId SdpId,
tmnxDot1agCfmSdpMipVcId Unsigned32,
tmnxDot1agCfmSdpMipRowStatus RowStatus,
tmnxDot1agCfmSdpMipSrcMacAddress MacAddress,
tmnxDot1agCfmSdpMipPrimaryVlanId VlanIdOrNone
}
tmnxDot1agCfmSdpMipSvcId OBJECT-TYPE
SYNTAX TmnxServId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpMipSvcId specifies the service identifier
index of the row."
::= { tmnxDot1agCfmSdpMipEntry 1 }
tmnxDot1agCfmSdpMipSdpId OBJECT-TYPE
SYNTAX SdpId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpMipSdpId specifies the SDP identifier
index of the row."
::= { tmnxDot1agCfmSdpMipEntry 2 }
tmnxDot1agCfmSdpMipVcId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpMipVcId specifies the Virtual Circuit
(VC) identifier index of the row."
::= { tmnxDot1agCfmSdpMipEntry 3 }
tmnxDot1agCfmSdpMipRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpMipRowStatus specifies the status of the
row. Creating/destroying a row creates/destroys a MIP."
::= { tmnxDot1agCfmSdpMipEntry 4 }
tmnxDot1agCfmSdpMipSrcMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpMipSrcMacAddress specifies the source MAC
address used by the MIP.
When the all-zeros MAC address is configured, SROS uses the chassis
MAC address (i.e. TIMETRA-CHASSIS-MIB::tmnxChassisBaseMacAddress) as
the MIP's source MAC address."
DEFVAL { '000000000000'H }
::= { tmnxDot1agCfmSdpMipEntry 5 }
tmnxDot1agCfmSdpMipPrimaryVlanId OBJECT-TYPE
SYNTAX VlanIdOrNone
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmSdpMipPrimaryVlanId specifies the Primary
VLAN identifier index of the row.
The tmnxDot1agCfmSdpMipEntry DESCRIPTION clause describes the
tmnxDot1agCfmSdpMipPrimaryVlanId = 0 case.
This index was added to the table in SROS release 15.0 R1."
::= { tmnxDot1agCfmSdpMipEntry 6 }
tmnxDot1agCfmNotificationObjs OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 9 }
tmnxDot1agCfmNotifySvcId OBJECT-TYPE
SYNTAX TmnxServId
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The tmnxDot1agCfmNotifySvcId is used in notifications when a row
consisting of the service identifier may not exist when the trap is
issued."
::= { tmnxDot1agCfmNotificationObjs 1 }
tmnxDot1agCfmMepFcltyType OBJECT-TYPE
SYNTAX TmnxDot1agCfmMepFclty
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFcltyType indicates the type of facility
that a facility MEP has affected via a raised or cleared event."
::= { tmnxDot1agCfmNotificationObjs 2 }
tmnxDot1agCfmMepFcltyInstance OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMepFcltyInstance indicates the specific
facility instance that a facility MEP has affected via a raised or
cleared event.
This value is used in combination with its tmnxDot1agCfmMepFcltyType.
The possible facility types and instance forms are described in the
following table:
Facility Type | Facility Instance
---------------------------------------------
port | slot/mda/port
lag | lag-id
networkInterface | interface name
qinqPortTunnelSap | sap-id
qinqLagTunnelSap | sap-id
The combined value will appear as in the following examples:
port 7/2/2
lag 1
networkInterface test
qinqPortTunnelSap 2/2/2:100.*
qinqLagTunnelSap lag-1:100.*
When a facility fault occurs on a QinQ port or lag, the sap executing
the CFM functional test, the sap will be included as part of the
event log message. However, QinQ facility tunnel MEPs on the sap are
only the detection point for the defect / clear condition. The QinQ
facility tunnel is port or lag based and a representative outer tag."
::= { tmnxDot1agCfmNotificationObjs 3 }
tmnxDot1agCfmDefaultMd OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 10 }
tmnxDot1agCfmDfltMdDefMipLtrPrio OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmDfltMdDefMipLtrPrio indicates at what
priority the link-trace response frames should be transmitted for a
MIP request, for each tmnxDot1agCfmDefaultMdEntry whose
tmnxDot1agCfmDefaultMdMipLtrPrio object contains the value '-1'.
This object defaults to, and only supports the value '7'."
::= { tmnxDot1agCfmDefaultMd 1 }
tmnxDot1agCfmDefaultMdTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmDefaultMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmDefaultMdTable AUGMENTS the standard MIB table,
dot1agCfmDefaultMdTable. This table is used to enhance the Default
Maintenance Domain functionality for Ethernet Connectivity Fault
Management (Eth-CFM)."
::= { tmnxDot1agCfmDefaultMd 2 }
tmnxDot1agCfmDefaultMdEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmDefaultMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmDefaultMdEntry consists of the configuration objects
used to enhance the Default Maintenance Domain functionality."
AUGMENTS { dot1agCfmDefaultMdEntry }
::= { tmnxDot1agCfmDefaultMdTable 1 }
TmnxDot1agCfmDefaultMdEntry ::= SEQUENCE
{ tmnxDot1agCfmDefaultMdMipLtrPrio Integer32 }
tmnxDot1agCfmDefaultMdMipLtrPrio OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmDefaultMdMipLtrPrio specifies at what
priority the link-trace response frames should be transmitted for a
MIP request.
If this object has the value '-1', the priority of this entry is
deferred to tmnxDot1agCfmDfltMdDefMipLtrPrio."
DEFVAL { -1 }
::= { tmnxDot1agCfmDefaultMdEntry 1 }
tmnxDot1agLearnedRemoteMacObjs OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 11 }
tmnxDot1agCfmLearnedRmtMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmLearnedRmtMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmLearnedRmtMacTable stores the remote MEP MAC
addresses that have been learned when receiving CCM PDUs on a local
MEP."
::= { tmnxDot1agLearnedRemoteMacObjs 1 }
tmnxDot1agCfmLearnedRmtMacEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmLearnedRmtMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmLearnedRmtMacEntry consists of the remote MEP MAC
address that has been learned by a local MEP as well as information
about the state of the remote MEP MAC address.
Rows are managed by the system and can not be created or destroyed
using SNMP set requests."
INDEX {
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
tmnxDot1agCfmLearnedRmtMepId
}
::= { tmnxDot1agCfmLearnedRmtMacTable 1 }
TmnxDot1agCfmLearnedRmtMacEntry ::= SEQUENCE
{
tmnxDot1agCfmLearnedRmtMepId Dot1agCfmMepId,
tmnxDot1agCfmLearnedRmtMacAddr MacAddress,
tmnxDot1agCfmLearnedRmtStaleFlag TruthValue,
tmnxDot1agCfmLearnedRmtChngdFlag TruthValue
}
tmnxDot1agCfmLearnedRmtMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmLearnedRmtMepId indicates the remote MEP
identifier associated with the entry."
::= { tmnxDot1agCfmLearnedRmtMacEntry 1 }
tmnxDot1agCfmLearnedRmtMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmLearnedRmtMacAddr indicates the source MAC
address used by the remote MEP in the most recently received CCM PDU."
::= { tmnxDot1agCfmLearnedRmtMacEntry 2 }
tmnxDot1agCfmLearnedRmtStaleFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmLearnedRmtStaleFlag indicates if the learned
MAC entry for this remote MEP matches the entry found in the
dot1agCfmMepDbTable.
The value 'false' indicates that the MAC address matches the entry
found in both the tables for the same local and remote MEP values and
therefore is not considered stale.
The value 'true' indicates either the entries do not match, or there
is no equivalent entry for the remote MEP in the dot1agCfmMepDbTable
so the learned remote MAC address in this table is considered stale."
::= { tmnxDot1agCfmLearnedRmtMacEntry 3 }
tmnxDot1agCfmLearnedRmtChngdFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmLearnedRmtChngdFlag indicates if the learned
MAC entry for this remote MEP has been modified in the last CCM
interval of the local MEP.
The value 'true' indicates that the local MEP received a CCM from the
remote MEP with a MAC address that does not match the address in the
tmnxDot1agCfmLearnedRmtMacAddr from the last CCM interval of the local
MEP. The new address will be stored in tmnxDot1agCfmLearnedRmtMacAddr.
The value 'false' indicates a new entry or an entry where
tmnxDot1agCfmLearnedRmtMacAddr has not changed in over one CCM
interval.
This object can be used to detect if a remote MEP MAC address has
recently changed. This may help detect configuration changes of
remote MEP MAC addresses, or possibly duplicate remote MEPs configured
in the network."
::= { tmnxDot1agCfmLearnedRmtMacEntry 4 }
tmnxDot1agCfmMdMgmt OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 12 }
tmnxDot1agCfmMdMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMdMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMdMgmtTable manages the row creation and deletion of
dot1agCfmMdTable rows. This table replaces the standard row creation
model for Dot1ag CFM Maintenance Domains to better facilitate Nokia
SROS series requirements. The use of writing to the
IEEE-8021-CFM-MIB::dot1agCfmMdRowStatus object is deprecated and
should be discouraged in favor of this table."
::= { tmnxDot1agCfmMdMgmt 1 }
tmnxDot1agCfmMdMgmtEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMdMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMdMgmtEntry consists of the configuration objects
used for the purpose of row creation for Nokia SROS Dot1ag Maintenance
Domains."
AUGMENTS { dot1agCfmMdEntry }
::= { tmnxDot1agCfmMdMgmtTable 1 }
TmnxDot1agCfmMdMgmtEntry ::= SEQUENCE
{
tmnxDot1agCfmMdMgmtRowStatus RowStatus,
tmnxDot1agCfmMdMgmtFormat Dot1agCfmMaintDomainNameType,
tmnxDot1agCfmMdMgmtName TmnxDot1agCfmMaintDomainNameOrEmpty,
tmnxDot1agCfmMdMgmtMdLevel Dot1agCfmMDLevel,
tmnxDot1agCfmMdMgmtAdminName TLNamedItemOrEmpty
}
tmnxDot1agCfmMdMgmtRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMdMgmtRowStatus specifies the row status of
the dot1ag CFM MEP. This object replaces the use of the
IEEE-8021-CFM-MIB::dot1agCfmMdRowStatus object."
::= { tmnxDot1agCfmMdMgmtEntry 1 }
tmnxDot1agCfmMdMgmtFormat OBJECT-TYPE
SYNTAX Dot1agCfmMaintDomainNameType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMdMgmtFormat specifies the type (and thereby
format) of the Maintenance Domain Name.
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMdFormat.
This object may be specified only during row creation."
DEFVAL { charString }
::= { tmnxDot1agCfmMdMgmtEntry 2 }
tmnxDot1agCfmMdMgmtName OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaintDomainNameOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMdMgmtName specifies the Maintenance Domain
name. The type/format of this object is determined by the value of the
dot1agCfmMdNameType object.
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMdName.
This object may be specified only during row creation."
DEFVAL { '44454641554c54'H }
::= { tmnxDot1agCfmMdMgmtEntry 3 }
tmnxDot1agCfmMdMgmtMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMdMgmtMdLevel specifies the Maintenance
Domain level.
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMdMdLevel.
This object may be specified only during row creation."
DEFVAL { 0 }
::= { tmnxDot1agCfmMdMgmtEntry 4 }
tmnxDot1agCfmMdMgmtAdminName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMdMgmtAdminName specifies a name that can be
used to uniquely identify a CFM Maintenance Domain. Historically, only
the arbitrary integer index, dot1agCfmMdIndex, would be used for this
purpose. A string provides greater flexibility and allows some amount
of context to also be included.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMdAdminName.
This object must be specified during row creation."
DEFVAL { ''H }
::= { tmnxDot1agCfmMdMgmtEntry 5 }
tmnxDot1agCfmMaMgmt OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 13 }
tmnxDot1agCfmMaMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMaMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaMgmtTable manages the row creation and deletion of
dot1agCfmMaNetTable rows. This table replaces the standard row
creation model for Dot1ag CFM Maintenance Domain Associations to
better facilitate Nokia SROS series requirements. The use of writing
to the IEEE-8021-CFM-MIB::dot1agCfmMaNetRowStatus object is deprecated
and should be discouraged in favor of this table."
::= { tmnxDot1agCfmMaMgmt 1 }
tmnxDot1agCfmMaMgmtEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaMgmtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaMgmtEntry consists of the configuration objects
used for the purpose of row creation for Nokia SROS Dot1ag Maintenance
Domain Associations."
AUGMENTS { dot1agCfmMaNetEntry }
::= { tmnxDot1agCfmMaMgmtTable 1 }
TmnxDot1agCfmMaMgmtEntry ::= SEQUENCE
{
tmnxDot1agCfmMaMgmtRowStatus RowStatus,
tmnxDot1agCfmMaMgmtFormat TmnxDot1agCfmMaintAssocNameType,
tmnxDot1agCfmMaMgmtName Dot1agCfmMaintAssocName,
tmnxDot1agCfmMaMgmtCcmInterval TmnxDot1agCfmCcmInterval,
tmnxDot1agCfmMaMgmtAdminName TLNamedItemOrEmpty,
tmnxDot1agCfmMaMgmtHoldDownTimer Unsigned32,
tmnxDot1agCfmMaMgmtAutoDiscAdmin TruthValue,
tmnxDot1agCfmMaMgmtIdPermission TmnxDot1agCfmIdPermission
}
tmnxDot1agCfmMaMgmtRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMgmtRowStatus specifies the row status of
the dot1ag CFM Maintenance Association. This object replaces the use
of the IEEE-8021-CFM-MIB::dot1agCfmMaNetRowStatus object."
::= { tmnxDot1agCfmMaMgmtEntry 1 }
tmnxDot1agCfmMaMgmtFormat OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaintAssocNameType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMgmtFormat specifies the type (and thereby
format) of the Maintenance Association Name.
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMaNetFormat.
This object may be specified only during row creation."
::= { tmnxDot1agCfmMaMgmtEntry 2 }
tmnxDot1agCfmMaMgmtName OBJECT-TYPE
SYNTAX Dot1agCfmMaintAssocName
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMgmtName specifies the Short Maintenance
Association name. The type/format of this object is determined by the
value of the dot1agCfmMaNetNameType object. This name must be unique
within a maintenance domain.
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMaNetName.
This object may be specified only during row creation."
::= { tmnxDot1agCfmMaMgmtEntry 3 }
tmnxDot1agCfmMaMgmtCcmInterval OBJECT-TYPE
SYNTAX TmnxDot1agCfmCcmInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMgmtCcmInterval specifies the interval
between CCM transmissions to be used by all MEPs in the MA.
This object refers directly to
IEEE8021-CFM-MIB::dot1agCfmMaNetCcmInterval."
DEFVAL { interval10s }
::= { tmnxDot1agCfmMaMgmtEntry 4 }
tmnxDot1agCfmMaMgmtAdminName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMgmtAdminName specifies a name that can be
used to uniquely identify a CFM Maintenance Association. Historically,
only the arbitrary integer index, dot1agCfmMaIndex, would be used for
this purpose. A string provides greater flexibility and allows some
amount of context to also be included.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaNetAdminName.
This object must be specified during row creation."
DEFVAL { ''H }
::= { tmnxDot1agCfmMaMgmtEntry 5 }
tmnxDot1agCfmMaMgmtHoldDownTimer OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..1000)
UNITS "centiseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMgmtHoldDownTimer specifies the time, in
centiseconds, that a MEP in the association will delay declaring a
fault. This delay is added on to the existing
3.5 * dot1agCfmMaNetCcmInterval value used to determine if a
connectivity fault to the peer should be raised.
A value of zero (0) indicates that no additional delay should be added
to the existing 3.5 * dot1agCfmMaNetCcmInterval value.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaNetHoldDownTimer."
DEFVAL { 0 }
::= { tmnxDot1agCfmMaMgmtEntry 6 }
tmnxDot1agCfmMaMgmtAutoDiscAdmin OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMgmtAutoDiscAdmin specifies if remote MEP
automatic discovery is enabled in the association. A value of 'true'
indicates that a new remote MEP entry will be added to the
dot1agCfmMepDbTable when the node receives a CCM PDU from a remote
MEP that is not yet in that table (up to the maximum limit of MEPs
allowed in the association). A value of 'false' indicates that remote
MEPs must be manually configured in the association
dot1agCfmMaMepListTable before being added to the association
dot1agCfmMepDbTable.
This object refers directly to
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaNetAutoDiscAdmin."
DEFVAL { false }
::= { tmnxDot1agCfmMaMgmtEntry 7 }
tmnxDot1agCfmMaMgmtIdPermission OBJECT-TYPE
SYNTAX TmnxDot1agCfmIdPermission
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaMgmtIdPermission specifies what, if
anything, is to be included in the Sender ID TLV (21.5.3) transmitted
by MPs configured in this MA. This object is configurable on MA
entries that do not consist of component entries. This object refers
directly to TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaNetIdPermission."
REFERENCE
"802.1ag clause 12.14.6.1.3:d"
DEFVAL { sendIdNone }
::= { tmnxDot1agCfmMaMgmtEntry 8 }
tmnxDot1agCfmMaBrName OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 14 }
tmnxDot1agCfmMaBrNameTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxDot1agCfmMaBrNameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaBrNameTable optionally replaces the standard row
creation model for Dot1ag CFM Maintenance Domain Association
Components. The tmnxDot1agCfmMaBrNameId allows for named references
linking to the bridging instance. The use of writing to the
IEEE-8021-CFM-MIB::dot1agCfmMaCompRowStatus object is mutually
exclusive from writing to the
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaBrNameRowStatus."
::= { tmnxDot1agCfmMaBrName 1 }
tmnxDot1agCfmMaBrNameEntry OBJECT-TYPE
SYNTAX TmnxDot1agCfmMaBrNameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMaBrNameEntry consists of the configuration objects
used for the purpose of row creation for Nokia SROS Dot1ag Maintenance
Domain Association Components using a name as a key."
INDEX {
tmnxDot1agCfmMaBrNameId,
dot1agCfmMdIndex,
dot1agCfmMaIndex
}
::= { tmnxDot1agCfmMaBrNameTable 1 }
TmnxDot1agCfmMaBrNameEntry ::= SEQUENCE
{
tmnxDot1agCfmMaBrNameId TLNamedItem,
tmnxDot1agCfmMaBrNamePVlanId VlanIdOrNone,
tmnxDot1agCfmMaBrNameMhfCreation TmnxDot1agCfmMhfCreation,
tmnxDot1agCfmMaBrNameIdPerm TmnxDot1agCfmIdPermission,
tmnxDot1agCfmMaBrNameMipLtrPrio Unsigned32,
tmnxDot1agCfmMaBrNameNumOfVids Unsigned32,
tmnxDot1agCfmMaBrNameRowStatus RowStatus
}
tmnxDot1agCfmMaBrNameId OBJECT-TYPE
SYNTAX TLNamedItem
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaBrNameId specifies a name that can be used
to uniquely identify a CFM Maintenance Association Component.
Historically, only the arbitrary integer index,
dot1agCfmMaComponentId, would be used for this purpose. A string
provides greater flexibility and allows some amount of context to also
be included."
::= { tmnxDot1agCfmMaBrNameEntry 1 }
tmnxDot1agCfmMaBrNamePVlanId OBJECT-TYPE
SYNTAX VlanIdOrNone
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaBrNamePVlanId specifies the Primary VLAN
ID with which the Maintenance Association is associated, or 0 if the
MA is not attached to any VID. If the MA is associated with more than
one VID, the dot1agCfmVlanTable lists them."
REFERENCE
"802.1ag clause 12.14.6.1.3:b"
::= { tmnxDot1agCfmMaBrNameEntry 2 }
tmnxDot1agCfmMaBrNameMhfCreation OBJECT-TYPE
SYNTAX TmnxDot1agCfmMhfCreation
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaBrNameMhfCreation specifies if the
Management entity can create MHFs (MIP Half Function) for this MA."
REFERENCE
"802.1ag clause 12.14.6.1.3:c"
DEFVAL { defMHFnone }
::= { tmnxDot1agCfmMaBrNameEntry 3 }
tmnxDot1agCfmMaBrNameIdPerm OBJECT-TYPE
SYNTAX TmnxDot1agCfmIdPermission
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaBrNameIdPerm specifies what, if anything,
is to be included in the Sender ID TLV (21.5.3) transmitted by MPs
configured in this MA."
REFERENCE
"802.1ag clause 12.14.6.1.3:d"
DEFVAL { sendIdNone }
::= { tmnxDot1agCfmMaBrNameEntry 4 }
tmnxDot1agCfmMaBrNameMipLtrPrio OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaBrNameMipLtrPrio specifies at what
priority the link-trace response frames should be transmitted for a
MIP request."
DEFVAL { 7 }
::= { tmnxDot1agCfmMaBrNameEntry 5 }
tmnxDot1agCfmMaBrNameNumOfVids OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaBrNameNumOfVids indicates the number of
VIDs associated with the MA."
REFERENCE
"802.1ag clause 12.14.6.1.3:b"
::= { tmnxDot1agCfmMaBrNameEntry 6 }
tmnxDot1agCfmMaBrNameRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxDot1agCfmMaBrNameRowStatus specifies the row status
of the dot1ag CFM Maintenance Association. This object optionally
replaces the use of the IEEE-8021-CFM-MIB::dot1agCfmMaCompRowStatus
object."
::= { tmnxDot1agCfmMaBrNameEntry 7 }
tmnxDot1agMIBConformance OBJECT IDENTIFIER ::= { tmnxSRConfs 52 }
tmnxDot1agCfmCompliances OBJECT IDENTIFIER ::= { tmnxDot1agMIBConformance 1 }
tmnxDot1agCfmCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 1.0 of TIMETRA-IEEE8021-CFM-MIB."
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmSdpBindStackGroup,
tmnxDot1agCfmMepGroup,
tmnxDot1agCfmSapStackGroup
}
::= { tmnxDot1agCfmCompliances 1 }
tmnxDot1agCfmComplianceV7v0 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 7.0 of the SROS system"
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmSdpBindStackGroup,
tmnxDot1agCfmSapStackGroup,
tmnxDot1agCfmNotificationGroup,
tmnxY1731CfmNotificationGroup,
tmnxDot1agCfmMipGroup,
tmnxDot1agCfmMipNotifyGroup,
tmnxDot1agCfmMepGroupV7v0
}
::= { tmnxDot1agCfmCompliances 2 }
tmnxDot1agCfmComplianceV8v0 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 8.0 of the SROS system"
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmSdpBindStackGroup,
tmnxDot1agCfmSapStackGroup,
tmnxDot1agCfmNotificationGroup,
tmnxY1731CfmNotificationGroup,
tmnxDot1agCfmMipNotifyGroup,
tmnxDot1agCfmMipGroupV8v0,
tmnxDot1agCfmMepGroupV7v0,
tmnxDot1agCfmMepGroupV8v0
}
::= { tmnxDot1agCfmCompliances 3 }
tmnxDot1agCfmComplianceV9v0 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 9.0 of the SROS system"
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmMaGroupV9v0,
tmnxDot1agCfmSdpBindStackGroup,
tmnxDot1agCfmSapStackGroup,
tmnxDot1agCfmNotificationGroup,
tmnxY1731CfmNotificationGroup,
tmnxDot1agCfmMipNotifyGroup,
tmnxDot1agCfmMipGroupV8v0,
tmnxDot1agCfmMepGroupV7v0,
tmnxDot1agCfmMepGroupV8v0,
tmnxDot1agCfmMepGroupV9v0,
tmnxDot1agCfmGlobalGroupV9v0,
tmnxDot1agCfmMepSlmGroupV9v0,
tmnxDot1agCfmMepSlmNotifyGroup,
tmnxDot1agCfmMepMcastLbmGroup
}
::= { tmnxDot1agCfmCompliances 4 }
tmnxDot1agCfmComplianceV10v0 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 10.0 of the SROS system"
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmGlobalGroupV9v0,
tmnxDot1agCfmMaGroupV9v0,
tmnxDot1agCfmMaGroupV10v0,
tmnxDot1agCfmMepGroupV7v0,
tmnxDot1agCfmMepGroupV8v0,
tmnxDot1agCfmMepGroupV9v0,
tmnxDot1agCfmMepGroupV10v0,
tmnxDot1agCfmMepMcastLbmGroup,
tmnxDot1agCfmMepSlmGroupV9v0,
tmnxDot1agCfmMepSlmNotifyGroup,
tmnxDot1agCfmMepSlmTWGroupV10v0,
tmnxDot1agCfmMipGroupV8v0,
tmnxDot1agCfmMipNotifyGroup,
tmnxDot1agCfmNotificationGroup,
tmnxDot1agCfmSapStackGroup,
tmnxDot1agCfmSdpBindStackGroup,
tmnxDot1agCfmStatsGroupV10v0,
tmnxY1731CfmNotificationGroup,
tmnxDot1agCfmGPGroupV10v0
}
::= { tmnxDot1agCfmCompliances 5 }
tmnxDot1agCfmComplianceV11v0 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 11.0 of the SROS system"
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmGlobalGroupV9v0,
tmnxDot1agCfmMaGroupV9v0,
tmnxDot1agCfmMaGroupV10v0,
tmnxDot1agCfmMaGroupV11v0,
tmnxDot1agCfmMepGroupV7v0,
tmnxDot1agCfmMepGroupV8v0,
tmnxDot1agCfmMepGroupV9v0,
tmnxDot1agCfmMepGroupV10v0,
tmnxDot1agCfmMepCSFGroupV11v0,
tmnxDot1agCfmMepMcastLbmGroup,
tmnxDot1agCfmMepSlmGroupV9v0,
tmnxDot1agCfmMepSlmNotifyGroup,
tmnxDot1agCfmMepSlmTWGroupV10v0,
tmnxDot1agCfmMipGroupV8v0,
tmnxDot1agCfmMipNotifyGroup,
tmnxDot1agCfmNotificationGroup,
tmnxDot1agCfmCSFNotifyGroupV11v0,
tmnxDot1agCfmSapStackGroup,
tmnxDot1agCfmSdpBindStackGroup,
tmnxDot1agCfmStatsGroupV10v0,
tmnxY1731CfmNotificationGroup,
tmnxDot1agCfmGPGroupV10v0,
tmnxDot1agCfmMEPMgmtGroupV11v0,
tmnxDot1agCfmMdGroupV11v0
}
::= { tmnxDot1agCfmCompliances 6 }
tmnxDot1agCfmComplianceV12v0 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for revision 12.0 of the SROS system"
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmGlobalGroupV9v0,
tmnxDot1agCfmMaGroupV9v0,
tmnxDot1agCfmMaGroupV10v0,
tmnxDot1agCfmMaGroupV11v0,
tmnxDot1agCfmMaGroupV12v0,
tmnxDot1agCfmMepGroupV7v0,
tmnxDot1agCfmMepGroupV8v0,
tmnxDot1agCfmMepGroupV9v0,
tmnxDot1agCfmMepGroupV10v0,
tmnxDot1agCfmMepCSFGroupV11v0,
tmnxDot1agCfmMepGroupV12v0,
tmnxDot1agCfmMepMcastLbmGroup,
tmnxDot1agCfmMepSlmGroupV9v0,
tmnxDot1agCfmMepSlmNotifyGroup,
tmnxDot1agCfmMepSlmTWGroupV10v0,
tmnxDot1agCfmMipGroupV8v0,
tmnxDot1agCfmMipNotifyGroup,
tmnxDot1agCfmNotificationGroup,
tmnxDot1agCfmCSFNotifyGroupV11v0,
tmnxDot1agCfmSapStackGroup,
tmnxDot1agCfmSdpBindStackGroup,
tmnxDot1agCfmStatsGroupV10v0,
tmnxDot1agCfmStatsGroupV12v0,
tmnxY1731CfmNotificationGroup,
tmnxDot1agCfmGPGroupV10v0,
tmnxDot1agCfmMEPMgmtGroupV11v0,
tmnxDot1agCfmMdGroupV11v0,
tmnxDot1agCfmScalarsGroupV12v0
}
::= { tmnxDot1agCfmCompliances 7 }
tmnxDot1agCfmComplianceV13v0 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the object groups added in SROS Release
13.0."
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmMepGroupV13v0,
tmnxDot1agCfmXmppEnhGroup
}
::= { tmnxDot1agCfmCompliances 8 }
tmnxDot1agCfmComplianceV14v0 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the management of Ethernet Connectivity
Fault Management (Eth-CFM) for release 14.0 on Nokia SROS series
systems."
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmDefaultMdGroupV14v0,
tmnxDot1agNotifyObjsGroupV14v0,
tmnxDot1agCfmCLENotifyGroupV14v0
}
::= { tmnxDot1agCfmCompliances 9 }
tmnxDot1agCfmComplianceV15v0 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the management of Ethernet Connectivity
Fault Management (Eth-CFM) for release 15.0 on Nokia SROS series
systems."
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmMepGroupV15v0,
tmnxDot1agCfmTstMepIdGroupV15v0,
tmnxDot1agCfmLmmPerQosGroupV15v0,
tmnxDot1agCfmMccEdGroupV15v0,
tmnxDot1agCfmSdpPrimVLanGrpV15v0,
tmnxDot1agCfmLbmLbrMepGroupV15v0
}
::= { tmnxDot1agCfmCompliances 10 }
tmnxDot1agCfmComplianceV15v1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the management of Ethernet Connectivity
Fault Management (Eth-CFM) for release 15.1 on Nokia SROS series
systems."
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmAdminNameGroup
}
::= { tmnxDot1agCfmCompliances 11 }
tmnxDot1AgCfmComplianceV16v0 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the management of Ethernet Connectivity
Fault Management (Eth-CFM) for release 16.0 on Nokia SROS series
systems."
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmEthBnGroup,
tmnxDot1agCfmMaBrNameGroup,
tmnxDot1agCfmAdminNameGroupExt,
tmnxDot1agCfmModelDrivenGroup
}
::= { tmnxDot1agCfmCompliances 12 }
tmnxDot1agCfmComplianceV19v0 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the management of Ethernet Connectivity
Fault Management (Eth-CFM) for release 19.5 on Nokia SROS series
systems."
MODULE
MANDATORY-GROUPS {
tmnxDot1agCfmMepIXRGroup
}
::= { tmnxDot1agCfmCompliances 13 }
tmnxDot1agCfmGroups OBJECT IDENTIFIER ::= { tmnxDot1agMIBConformance 2 }
tmnxDot1agCfmSdpBindStackGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmSdpBindStackMdIndex,
tmnxDot1agCfmSdpBindStackMaIndex,
tmnxDot1agCfmSdpBindStackMepId,
tmnxDot1agCfmSdpBindStackMacAddress
}
STATUS current
DESCRIPTION
"The group of objects for management of dot1ag Stack Table applicable
to implementing SDP-Bindings."
::= { tmnxDot1agCfmGroups 1 }
tmnxDot1agCfmMepGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepSdpId,
tmnxDot1agCfmMepVcId,
tmnxDot1agCfmMepMacAddress
}
STATUS obsolete
DESCRIPTION
"The group of objects for management of dot1ag MEP Table applicable to
implementing SDP-Bindings."
::= { tmnxDot1agCfmGroups 2 }
tmnxDot1agCfmSapStackGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmStackMdIndex,
tmnxDot1agCfmStackMaIndex,
tmnxDot1agCfmStackMepId,
tmnxDot1agCfmStackMacAddress
}
STATUS current
DESCRIPTION
"The group of objects for management of dot1ag Stack Table applicable
to implementing SAP on the SROS."
::= { tmnxDot1agCfmGroups 3 }
tmnxDot1agCfmNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxDot1agCfmMepLbmTestComplete,
tmnxDot1agCfmMepLtmTestComplete
}
STATUS current
DESCRIPTION
"The group of objects for management of dot1ag Notifications applicable
to implementing CFM on the SROS."
::= { tmnxDot1agCfmGroups 4 }
tmnxDot1agCfmMipGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmSapMipRowStatus,
tmnxDot1agCfmSdpMipRowStatus
}
STATUS obsolete
DESCRIPTION
"The group of objects for management of dot1ag MIP Tables applicable to
implementing MIPs."
::= { tmnxDot1agCfmGroups 5 }
tmnxDot1agCfmMepGroupV7v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepSdpId,
tmnxDot1agCfmMepVcId,
tmnxDot1agCfmMepMacAddress,
tmnxDot1agCfmMepAisEnable,
tmnxDot1agCfmMepAisMegLevel,
tmnxDot1agCfmMepAisPriority,
tmnxDot1agCfmMepAisInterval,
tmnxDot1agCfmMepEthTestEnable,
tmnxDot1agCfmMepEthTestPattern,
tmnxDot1agCfmMepEthRxAisInterval,
tmnxDot1agCfmMepEthRxAis,
tmnxDot1agCfmMepEthAisTxCount,
tmnxDot1agCfmMepEthTestMacAddr,
tmnxDot1agCfmMepEthTestDataLen,
tmnxDot1agCfmMepEthTestPriority,
tmnxDot1agCfmMepOWDTMacAddress,
tmnxDot1agCfmMepOWDTPriority,
tmnxDot1agCfmMepTWDTMacAddress,
tmnxDot1agCfmMepTWDTPriority,
tmnxDot1agCfmMepFrameCount,
tmnxDot1agCfmMepByteCount,
tmnxDot1agCfmMepFailedBits,
tmnxDot1agCfmMepCrcFailures,
tmnxDot1agCfmMepCurrByteCount,
tmnxDot1agCfmMepCurrFailedBits,
tmnxDot1agCfmMepCurrCrcFailures,
tmnxDot1agCfmMepDelayTestDelay,
tmnxDot1agCfmMepDelayVariation,
tmnxDot1agCfmMepSvcId,
tmnxDot1agCfmMepControlMep,
tmnxDot1agCfmMepEthTestThreshold,
tmnxDot1agCfmMepOWDTThreshold,
tmnxDot1agCfmVStackMdIndex,
tmnxDot1agCfmVStackMaIndex,
tmnxDot1agCfmVStackMepId,
tmnxDot1agCfmVStackMacAddress,
tmnxDot1agCfmStackMPType
}
STATUS current
DESCRIPTION
"The group of objects for managing dot1ag and Y.1731 tables applicable
to Virtual MEPs and MEGs on SROS R7.0, and enabling APS support."
::= { tmnxDot1agCfmGroups 6 }
tmnxY1731CfmNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxDot1agCfmMepEthTestComplete,
tmnxDot1agCfmMepDMTestComplete,
tmnxDot1agCfmMepAisStateChanged
}
STATUS current
DESCRIPTION
"The group of objects for management of Y.1731 Notifications applicable
to implementing CFM on the SROS."
::= { tmnxDot1agCfmGroups 7 }
tmnxDot1agCfmNotifyObjsGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmNotifySvcId
}
STATUS current
DESCRIPTION
"The group of objects supporting notifications for revision 7.0 on
Nokia SROS series systems."
::= { tmnxDot1agCfmGroups 8 }
tmnxDot1agCfmMipNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxDot1agCfmMipEvaluation
}
STATUS current
DESCRIPTION
"The group of notification objects for management of dot1ag MIPs."
::= { tmnxDot1agCfmGroups 9 }
tmnxDot1agCfmV6v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 10 }
tmnxDot1agCfmV7v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 11 }
tmnxDot1agCfmV8v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 12 }
tmnxDot1agCfmMipGroupV8v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmSapMipRowStatus,
tmnxDot1agCfmSapMipSrcMacAddress,
tmnxDot1agCfmSdpMipRowStatus,
tmnxDot1agCfmSdpMipSrcMacAddress
}
STATUS current
DESCRIPTION
"The group of objects for management of dot1ag MIP Tables applicable to
implementing MIPs for SROS release 8.0."
::= { tmnxDot1agCfmV8v0Groups 1 }
tmnxDot1agCfmMepGroupV8v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepFaultPropagation
}
STATUS current
DESCRIPTION
"The group of objects for managing dot1ag and Y.1731 tables applicable
to Virtual MEPs and MEGs on SROS R8.0, and enabling APS support."
::= { tmnxDot1agCfmV8v0Groups 2 }
tmnxDot1agCfmV9v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 13 }
tmnxDot1agCfmMaGroupV9v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMaNetHoldDownTimer
}
STATUS current
DESCRIPTION
"The group of objects for management of dot1ag and Y.1731 tables
applicable to enhancing Maintenance Associations for the SROS release
9.0."
::= { tmnxDot1agCfmV9v0Groups 1 }
tmnxDot1agCfmMepGroupV9v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepFacilityIfIndex,
tmnxDot1agCfmMepFacilityVlanId,
tmnxDot1agCfmMepFacilityType,
tmnxDot1agCfmMepFcltyFaultNotify,
tmnxDot1agCfmMepDescription,
tmnxDot1agCfmMepMcLagInactive
}
STATUS current
DESCRIPTION
"The group of objects for management of dot1ag and Y.1731 tables
applicable to implementing Facility MEPs for the SROS release 9.0."
::= { tmnxDot1agCfmV9v0Groups 2 }
tmnxDot1agCfmGlobalGroupV9v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMcLagStdbyInactive,
tmnxDot1agCfmMcLagPropHoldTime
}
STATUS current
DESCRIPTION
"The group of global objects for enhancing dot1ag and Y.1731 features
with support for Multi-Chassis LAG ports for the SROS release 9.0."
::= { tmnxDot1agCfmV9v0Groups 3 }
tmnxDot1agCfmMepSlmGroupV9v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmSLMInactivityTimer,
tmnxDot1agCfmMepSlmTWTestStatus,
tmnxDot1agCfmMepSlmTWTestId,
tmnxDot1agCfmMepSlmTWMacAddress,
tmnxDot1agCfmMepSlmTWPriority,
tmnxDot1agCfmMepSlmTWInterval,
tmnxDot1agCfmMepSlmTWTimeout,
tmnxDot1agCfmMepSlmTWDataSize,
tmnxDot1agCfmMepSlmTWSendCount,
tmnxDot1agCfmMepSlmOWTestStatus,
tmnxDot1agCfmMepSlmOWTestId,
tmnxDot1agCfmMepSlmOWMacAddress,
tmnxDot1agCfmMepSlmOWPriority,
tmnxDot1agCfmMepSlmOWInterval,
tmnxDot1agCfmMepSlmOWDataSize,
tmnxDot1agCfmMepSlmOWSendCount,
tmnxDot1agCfmMepSlmTestId,
tmnxDot1agCfmMepSlmRemoteMepId,
tmnxDot1agCfmMepSlmLastTxSeqF,
tmnxDot1agCfmMepSlmPacketIn,
tmnxDot1agCfmMepSlmPacketLossIn,
tmnxDot1agCfmMepSlmPacketLossOut,
tmnxDot1agCfmMepSlmPacketUnack
}
STATUS current
DESCRIPTION
"The group of objects for management of Synthetic Loss Measurement
Tests for the SROS release 9.0."
::= { tmnxDot1agCfmV9v0Groups 4 }
tmnxDot1agCfmMepSlmNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxDot1agCfmMepSLMTestComplete
}
STATUS current
DESCRIPTION
"The group of notification objects for management of dot1ag Synthetic
Loss Measurement (SLM) test for the SROS release 9.0."
::= { tmnxDot1agCfmV9v0Groups 5 }
tmnxDot1agCfmMepMcastLbmGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepLbmRxIndex
}
STATUS current
DESCRIPTION
"The group of objects for management of multicast loopback tests for
the SROS release 9.0."
::= { tmnxDot1agCfmV9v0Groups 6 }
tmnxDot1agCfmV10v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 14 }
tmnxDot1agCfmMepSlmTWGroupV10v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepSlmTWIntrvlUnits
}
STATUS current
DESCRIPTION
"The group of objects providing additional management options for
two-way SLM tests in SROS Release 10.0."
::= { tmnxDot1agCfmV10v0Groups 1 }
tmnxDot1agCfmMaGroupV10v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMaMepListMacAddress,
tmnxDot1agCfmMaNetTotalMEPCount
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
tables applicable to Maintenance Associations for the SROS release
10.0."
::= { tmnxDot1agCfmV10v0Groups 2 }
tmnxDot1agCfmMepGroupV10v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepCcmPaddingSize,
tmnxDot1agCfmMepCcmIgnoreTLVs,
tmnxDot1agCfmMepAisLowPrioDef
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
tables applicable to MEPs for the SROS release 10.0."
::= { tmnxDot1agCfmV10v0Groups 3 }
tmnxDot1agCfmStatsGroupV10v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmGlobalPacketRxCount,
tmnxDot1agCfmGlobalPacketTxCount,
tmnxDot1agCfmGlobalPacketDropped,
tmnxDot1agCfmGlobalPacketDiscard,
tmnxDot1agCfmCompName,
tmnxDot1agCfmCompResourceUsage,
tmnxDot1agCfmCompResourceLimit
}
STATUS current
DESCRIPTION
"The group of objects reporting dot1ag and Y.1731 global statistics
applicable for the SROS release 10.0."
::= { tmnxDot1agCfmV10v0Groups 4 }
tmnxDot1agCfmGPGroupV10v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmGraceTxEnable,
tmnxDot1agCfmGracePeriod,
tmnxDot1agCfmMepDbGraceRx
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
tables applicable to Continuity Check and the grace period
notifications."
::= { tmnxDot1agCfmV10v0Groups 5 }
tmnxDot1agCfmV11v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 15 }
tmnxDot1agCfmMEPMgmtGroupV11v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepMgmtRowStatus,
tmnxDot1agCfmMepMgmtType,
tmnxDot1agCfmMepMgmtServiceId,
tmnxDot1agCfmMepMgmtIfIndex,
tmnxDot1agCfmMepMgmtPrimaryVid,
tmnxDot1agCfmMepMgmtSdpId,
tmnxDot1agCfmMepMgmtVcId,
tmnxDot1agCfmMepMgmtFcltyIfIndex,
tmnxDot1agCfmMepMgmtFcltyVlanId,
tmnxDot1agCfmMepMgmtDirection,
tmnxDot1agCfmPVStackMdIndex,
tmnxDot1agCfmPVStackMaIndex,
tmnxDot1agCfmPVStackMepId,
tmnxDot1agCfmPVStackMacAddress
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
tables applicable to the row creation and deletion of MEPs."
::= { tmnxDot1agCfmV11v0Groups 1 }
tmnxDot1agCfmMaGroupV11v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMaCompMipLtrPrio
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
tables applicable to the Maintenance Association (MA)."
::= { tmnxDot1agCfmV11v0Groups 2 }
tmnxDot1agCfmMdGroupV11v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMdCreationOrigin
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
tables applicable to the Maintenance Domain (MD)."
::= { tmnxDot1agCfmV11v0Groups 3 }
tmnxDot1agCfmMepCSFGroupV11v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepCsfEnable,
tmnxDot1agCfmMepCsfRxMultiplier,
tmnxDot1agCfmMepCsfRxState,
tmnxDot1agCfmMepCsfRxInterval,
tmnxDot1agCfmMepCsfRxCount
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
MEP tables for the purpose of processing CSF (Client Signal Fault)
frames."
::= { tmnxDot1agCfmV11v0Groups 4 }
tmnxDot1agCfmCSFNotifyGroupV11v0 NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxDot1agCfmMepCsfStateChanged
}
STATUS current
DESCRIPTION
"The group of additional notifications for management of dot1ag and
Y.1731 MEP tables for the purpose of processing CSF (Client Signal
Fault) frames."
::= { tmnxDot1agCfmV11v0Groups 5 }
tmnxDot1agCfmV12v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 16 }
tmnxDot1agCfmMaGroupV12v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMaNetAutoDiscAdmin,
tmnxDot1agCfmMaMepListAutoDiscvd,
tmnxDot1agCfmMaNetIdPermission
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
tables applicable to Maintenance Associations for the SROS release
12.0."
::= { tmnxDot1agCfmV12v0Groups 1 }
tmnxDot1agCfmStatsGroupV12v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmGlobalOpcodeRx,
tmnxDot1agCfmGlobalOpcodeTx,
tmnxDot1agCfmGlobalAisTxActive,
tmnxDot1agCfmGlobalAisTxFail
}
STATUS current
DESCRIPTION
"The group of additional objects reporting dot1ag and Y.1731 global
statistics applicable for the SROS release 12.0."
::= { tmnxDot1agCfmV12v0Groups 2 }
tmnxDot1agCfmMepGroupV12v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepOpcodeRx,
tmnxDot1agCfmMepOpcodeTx,
tmnxDot1agCfmMepEthAisTxFail,
tmnxDot1agCfmMepTxLbmTimeout,
tmnxDot1agCfmMepTxLbmInterval,
tmnxDot1agCfmMepLbmPaddingSize,
tmnxDot1agCfmMepIfSupportEnable
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
tables applicable to MEPs for the SROS release 12.0."
::= { tmnxDot1agCfmV12v0Groups 3 }
tmnxDot1agCfmScalarsGroupV12v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmSenderIdType,
tmnxDot1agCfmSenderIdName
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
global configuration for the SROS release 12.0."
::= { tmnxDot1agCfmV12v0Groups 4 }
tmnxDot1agCfmV13v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 17 }
tmnxDot1agCfmMepGroupV13v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepCollectLmmStats
}
STATUS current
DESCRIPTION
"The group of additional objects for management of dot1ag and Y.1731
MEF tables for SROS release 13.0."
::= { tmnxDot1agCfmV13v0Groups 1 }
tmnxDot1agCfmXmppEnhGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepCreationOrigin
}
STATUS current
DESCRIPTION
"The group of additional objects for XMPP support for fully dynamic
services for SROS release 13.0R4."
::= { tmnxDot1agCfmV13v0Groups 2 }
tmnxDot1agCfmV14v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 18 }
tmnxDot1agCfmDefaultMdGroupV14v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmDfltMdDefMipLtrPrio,
tmnxDot1agCfmDefaultMdMipLtrPrio
}
STATUS current
DESCRIPTION
"The group of additional objects maintaining the Default Maintenance
Domain (MD) on Nokia SROS series systems for Release 14.0."
::= { tmnxDot1agCfmV14v0Groups 1 }
tmnxDot1agNotifyObjsGroupV14v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepFcltyType,
tmnxDot1agCfmMepFcltyInstance
}
STATUS current
DESCRIPTION
"The group of objects for management of CFM Facility MEP correlation
log events for the SROS release 14.0."
::= { tmnxDot1agCfmV14v0Groups 2 }
tmnxDot1agCfmCLENotifyGroupV14v0 NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxDot1agCfmMepFcltyFaultRaise,
tmnxDot1agCfmMepFcltyFaultClear
}
STATUS current
DESCRIPTION
"The group of notifications for management of the CFM Facility MEP
correlation log events for the SROS release 14.0."
::= { tmnxDot1agCfmV14v0Groups 3 }
tmnxDot1agCfmV15v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 19 }
tmnxDot1agCfmMepGroupV15v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepCcmTxRdi,
tmnxDot1agCfmMepCcmTxPortStatus,
tmnxDot1agCfmMepCcmTxIfStatus,
tmnxDot1agCfmMepTxAis,
tmnxDot1agCfmMepTxGrace,
tmnxDot1agCfmMepTxCcm
}
STATUS current
DESCRIPTION
"The group of additional objects maintaining the Maintenance
Association End Point (MEP) capabilities on Nokia SROS series systems
for Release 15.0."
::= { tmnxDot1agCfmV15v0Groups 1 }
tmnxDot1agCfmTstMepIdGroupV15v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepSlmOWTargetMepId,
tmnxDot1agCfmMepSlmOWLstDstMac,
tmnxDot1agCfmMepSlmTWTargetMepId,
tmnxDot1agCfmMepSlmTWLstDstMac,
tmnxDot1agCfmMepEthTestTargMepId,
tmnxDot1agCfmMepEthTestLstDstMac,
tmnxDot1agCfmMepOWDTTargetMepId,
tmnxDot1agCfmMepOWDTLstDstMac,
tmnxDot1agCfmMepTWDTTargetMepId,
tmnxDot1agCfmMepTWDTLstDstMac,
tmnxDot1agCfmLearnedRmtMacAddr,
tmnxDot1agCfmLearnedRmtStaleFlag,
tmnxDot1agCfmLearnedRmtChngdFlag
}
STATUS current
DESCRIPTION
"The group of objects required to provide additional management options
to allow CFM testing to remote MepId in SROS Release 15.0."
::= { tmnxDot1agCfmV15v0Groups 2 }
tmnxDot1agCfmLmmPerQosGroupV15v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepCollLmmFcSts,
tmnxDot1agCfmMepCollLmmFcStsInP
}
STATUS current
DESCRIPTION
"The group of objects supporting the ETH-LMM per QoS Class feature on
Nokia SROS series systems for Release 15.0."
::= { tmnxDot1agCfmV15v0Groups 3 }
tmnxDot1agCfmMccEdGroupV15v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepTxEthVsmGrace,
tmnxDot1agCfmMepRxEthVsmGrace,
tmnxDot1agCfmMepTxEthEd,
tmnxDot1agCfmMepRxEthEd,
tmnxDot1agCfmMepEthEdMaxDurRx,
tmnxDot1agCfmMepEthEdPriority,
tmnxDot1agCfmMepDbMccEdRx,
tmnxDot1agCfmMepOpRxPeerGrace
}
STATUS current
DESCRIPTION
"The group of objects supporting the ETH-MCC Ethernet Defect (ED)
feature on Nokia SROS series systems for Release 15.0."
::= { tmnxDot1agCfmV15v0Groups 4 }
tmnxDot1agCfmSdpPrimVLanGrpV15v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmSdpPVStackMdIndex,
tmnxDot1agCfmSdpPVStackMaIndex,
tmnxDot1agCfmSdpPVStackMepId,
tmnxDot1agCfmSdpPVStackMacAddr
}
STATUS current
DESCRIPTION
"The group of objects supporting Primary VLANs on SDP bindings on Nokia
SROS series systems for Release 15.0."
::= { tmnxDot1agCfmV15v0Groups 5 }
tmnxDot1agCfmLbmLbrMepGroupV15v0 OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepLbmSvcActResp
}
STATUS current
DESCRIPTION
"The group of objects supporting LBM and LBR MEP Processing on the IOM
on Nokia SROS series systems for Release 15.0."
::= { tmnxDot1agCfmV15v0Groups 6 }
tmnxDot1agCfmAdminNameGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMdAdminName,
tmnxDot1agCfmMaNetAdminName,
tmnxDot1agCfmMdMgmtRowStatus,
tmnxDot1agCfmMdMgmtName,
tmnxDot1agCfmMdMgmtFormat,
tmnxDot1agCfmMdMgmtMdLevel,
tmnxDot1agCfmMdMgmtAdminName,
tmnxDot1agCfmMaMgmtRowStatus,
tmnxDot1agCfmMaMgmtFormat,
tmnxDot1agCfmMaMgmtName,
tmnxDot1agCfmMaMgmtCcmInterval,
tmnxDot1agCfmMaMgmtAdminName
}
STATUS current
DESCRIPTION
"The group of objects supporting the addition of an admin name on Nokia
SROS series systems for Release 15.1."
::= { tmnxDot1agCfmV15v0Groups 7 }
tmnxDot1agCfmV16v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 20 }
tmnxDot1agCfmEthBnGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepEthBnReceive,
tmnxDot1agCfmMepEthBnRxUpdPacing,
tmnxDot1agCfmMepEthBnNominalBw,
tmnxDot1agCfmMepEthBnCurrentBw,
tmnxDot1agCfmMepEthBnReportedBw,
tmnxDot1agCfmMepEthBnLastReport,
tmnxDot1agCfmMepEthBnUpdPacTimer,
tmnxDot1agCfmMepEthBnPortId,
tmnxDot1agCfmMepEthBnRxInterval
}
STATUS current
DESCRIPTION
"The group of objects supporting the processing of Eth-BN messages on
Nokia SROS series systems in release 16.0."
::= { tmnxDot1agCfmV16v0Groups 1 }
tmnxDot1agCfmMaBrNameGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMaBrNamePVlanId,
tmnxDot1agCfmMaBrNameMhfCreation,
tmnxDot1agCfmMaBrNameIdPerm,
tmnxDot1agCfmMaBrNameMipLtrPrio,
tmnxDot1agCfmMaBrNameNumOfVids,
tmnxDot1agCfmMaBrNameRowStatus
}
STATUS current
DESCRIPTION
"The group of objects supporting the addition of a configurable bridge
name on Nokia SROS series systems in release 16.0."
::= { tmnxDot1agCfmV16v0Groups 2 }
tmnxDot1agCfmAdminNameGroupExt OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMaMgmtHoldDownTimer,
tmnxDot1agCfmMaMgmtAutoDiscAdmin,
tmnxDot1agCfmMaMgmtIdPermission
}
STATUS current
DESCRIPTION
"The group of objects added for additional support of admin name
management on Nokia SROS series systems for Release 16.0."
::= { tmnxDot1agCfmV16v0Groups 3 }
tmnxDot1agCfmModelDrivenGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agAutoMdIndexRangeStart,
tmnxDot1agAutoMdIndexRangeEnd,
tmnxDot1agAutoMaIndexRangeStart,
tmnxDot1agAutoMaIndexRangeEnd
}
STATUS current
DESCRIPTION
"The group of objects added to support model driven mode on Nokia SROS
series systems in release 16.0."
::= { tmnxDot1agCfmV16v0Groups 4 }
tmnxDot1agCfmV19v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 21 }
tmnxDot1agCfmMepIXRGroup OBJECT-GROUP
OBJECTS {
tmnxDot1agCfmMepInstallMep
}
STATUS current
DESCRIPTION
"The group of objects added to support MEP forwarding plane
installation on Nokia SROS series systems in release 19.5."
::= { tmnxDot1agCfmV19v0Groups 1 }
tmnxDot1agNotificationsPrefix OBJECT IDENTIFIER ::= { tmnxSRNotifyPrefix 52 }
tmnxDot1agNotifications OBJECT IDENTIFIER ::= { tmnxDot1agNotificationsPrefix 0 }
tmnxDot1agCfmMepLbmTestComplete NOTIFICATION-TYPE
OBJECTS {
dot1agCfmMepTransmitLbmDestMacAddress
}
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepLbmTestComplete notification indicates that a
loopback test has been issued and results are ready."
::= { tmnxDot1agNotifications 1 }
tmnxDot1agCfmMepLtmTestComplete NOTIFICATION-TYPE
OBJECTS {
dot1agCfmMepTransmitLtmSeqNumber
}
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepLtmTestComplete notification indicates that a
linktrace test has been issued and results are ready. The
dot1agCfmMepTransmitLtmSeqNumber indicates the Transaction Identifier
to use to retrieve the Link-trace results."
::= { tmnxDot1agNotifications 2 }
tmnxDot1agCfmMepEthTestComplete NOTIFICATION-TYPE
OBJECTS {
tmnxDot1agCfmMepCurrByteCount,
tmnxDot1agCfmMepCurrFailedBits,
tmnxDot1agCfmMepCurrCrcFailures
}
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepEthTestComplete notification indicates that an
eth-test has been issued and results are ready. The
tmnxDot1agCfmMepCurrByteCount indicates the number of bytes contained
in the frame's Test TLV, and the tmnxDot1agCfmMepCurrFailedBits and
tmnxDot1agCfmMepCurrCrcFailures indicate the failure state of the
test. A value of Zero (0) for tmnxDot1agCfmMepCurrFailedBits and a
value of 'false (2)' for tmnxDot1agCfmMepCurrCrcFailures indicates a
successful test."
::= { tmnxDot1agNotifications 3 }
tmnxDot1agCfmMepDMTestComplete NOTIFICATION-TYPE
OBJECTS {
tmnxDot1agCfmMepDelayTestDelay
}
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepDMTestComplete notification indicates that a
One-Way-Delay-Test (OWDT) frame, or a Two-Way-Delay-Test (TWDT)
response was received. For an OWDT frame, traps are raised only when a
delay threshold of three seconds is exceeded."
::= { tmnxDot1agNotifications 4 }
tmnxDot1agCfmMepAisStateChanged NOTIFICATION-TYPE
OBJECTS {
tmnxDot1agCfmMepEthRxAis
}
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepAisStateChanged notification is generated when a
MEP enters or exits an AIS state."
::= { tmnxDot1agNotifications 5 }
tmnxDot1agCfmMipEvaluation NOTIFICATION-TYPE
OBJECTS {
tmnxDot1agCfmNotifySvcId
}
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMipEvaluation notification is generated when a
virtual MEP is created or deleted causing MIP reevaluation on the
service. On virtual MEP creation, any MIPs in the service will be
removed. On virtual MEP deletion, the MIPs are reevaluated."
::= { tmnxDot1agNotifications 6 }
tmnxDot1agCfmMepSLMTestComplete NOTIFICATION-TYPE
OBJECTS {
tmnxDot1agCfmMepSlmTestId,
tmnxDot1agCfmMepSlmRemoteMepId,
tmnxDot1agCfmMepSlmLastTxSeqF,
tmnxDot1agCfmMepSlmPacketIn,
tmnxDot1agCfmMepSlmPacketLossIn,
tmnxDot1agCfmMepSlmPacketLossOut,
tmnxDot1agCfmMepSlmPacketUnack
}
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepSLMTestComplete notification is generated when a
two-way Synthetic Loss Measurement (SLM) test is completed."
::= { tmnxDot1agNotifications 7 }
tmnxDot1agCfmMepCsfStateChanged NOTIFICATION-TYPE
OBJECTS {
tmnxDot1agCfmMepCsfRxState
}
STATUS current
DESCRIPTION
"The tmnxDot1agCfmMepCsfStateChanged notification is generated when a
MEP enters or exits a CSF state."
::= { tmnxDot1agNotifications 8 }
tmnxDot1agCfmMepFcltyFaultRaise NOTIFICATION-TYPE
OBJECTS {
tmnxDot1agCfmMepFcltyType,
tmnxDot1agCfmMepFcltyInstance
}
STATUS current
DESCRIPTION
"[CAUSE] The tmnxDot1agCfmMepFcltyFaultRaise notification is generated
when the associated facility MEP dot1agCfmMepHighestPrDefect has
increased.
[EFFECT] This notification can be used to correlate the ETH_CFM
dot1agCfmFaultAlarm event and the related IF-MIB::linkDown
notification caused by the failure of the facility MEP.
[RECOVERY] Follow the recovery for the dot1agCfmFaultAlarm and the
related IF-MIB::linkDown caused by the failure of the facility MEP."
::= { tmnxDot1agNotifications 9 }
tmnxDot1agCfmMepFcltyFaultClear NOTIFICATION-TYPE
OBJECTS {
tmnxDot1agCfmMepFcltyType,
tmnxDot1agCfmMepFcltyInstance
}
STATUS current
DESCRIPTION
"[CAUSE] The tmnxDot1agCfmMepFcltyFaultClear notification is generated
when the associated facility MEP has cleared an event affecting the
specific tmnxDot1agCfmMepFcltyType tmnxDot1agCfmMepFcltyInstance
combination over which it is configured.
[EFFECT] This notification can be used to correlate the ETH_CFM
dot1agCfmFaultAlarm event and the related IF-MIB::linkUp notification
caused by the facility MEP."
::= { tmnxDot1agNotifications 10 }