Observium_CE/mibs/microsens/G6-SYSTEM-MIB

529 lines
15 KiB
Plaintext

G6-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter32, enterprises,NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, MacAddress
FROM SNMPv2-TC
g6 FROM MICROSENS-G6-MIB
;
device MODULE-IDENTITY --Category
LAST-UPDATED "201802121619Z"
ORGANIZATION "MICROSENS GmbH & Co. KG"
CONTACT-INFO
"Kueferstrasse 16
D-59067 Hamm
Germany
support@microsens.de
http://www.microsens.de"
DESCRIPTION
"Microsens private MIB for Generation 6 Ethernet Switches"
REVISION "201802121619Z"
DESCRIPTION
"File creation"
::= { g6 1 }
system OBJECT IDENTIFIER ::= { device 30 }
-- *************************** CONFIGURATION SECTION ********************************
systemShowTimeDate OBJECT-TYPE -- show_time_date
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Show system time and date."
::= { system 1 }
systemSetTime OBJECT-TYPE -- set_time
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the system clock (time only). Syntax: 12:30:00"
::= { system 2 }
systemSetDate OBJECT-TYPE -- set_date
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the system clock (date only). Syntax: 2012-12-24"
::= { system 3 }
systemShowUtilization OBJECT-TYPE -- show_utilization
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Show CPU status information"
::= { system 4 }
systemRebootDevice OBJECT-TYPE -- reboot_device
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This command will restart the device. All communication will be disrupted! Syntax: reboot_device = CONFIRM."
::= { system 5 }
systemCreateSnapshot OBJECT-TYPE -- create_snapshot
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Creates a snapshot of all relevant configuration and status information packaged as a single tar archieve. This file can be found in service/snapshot."
::= { system 6 }
systemSendWakeOnLanPacket OBJECT-TYPE -- send_wake_on_lan_packet
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This command will send a magic packet to wake up a selected sleeping device. The device is identified by its MAC address. Syntax: send_wake_on_lan_packet = 00:11:22:44:55:66."
::= { system 7 }
systemAlternativeMacAddress OBJECT-TYPE -- alternative_mac_address
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field is usually empty. This field may be used to override the MAC address fixed in the factory setting. NOTE: This value is only activated after a reset!"
::= { system 8 }
systemBootPreference OBJECT-TYPE -- boot_preference
SYNTAX INTEGER
{
sdCardFirst (0),
internalFirst (1),
sdCardOnly (2),
internalOnly (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This feature only applies to devices that feature internal memory plus plugged-in SD cards. It defines which software is used after reboot."
::= { system 9 }
systemInventory OBJECT-TYPE -- inventory
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Inventory string free for customer use. Up to 512 character are accepted. Note this config is linked to the SD card and may change when config or SD card is exchanged. For an inventory information that is fixed to the hardware use Device.Factory.custom_info command."
::= { system 10 }
systemAutorunCliScript OBJECT-TYPE -- autorun_cli_script
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Optional cli scripts executed after power sequence is completed. Several scripts may be assigned, with comma or blank separation."
::= { system 11 }
systemSerialPort OBJECT-TYPE -- serial_port
SYNTAX INTEGER
{
disabled (0),
console (1),
appControlled (2),
terminalServer (3),
smartSensor (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to DISABLED the local serial console port is disabled. Local access via serial cable is blocked. While this enhances local protection it also closes the emergency access should the device become inaccessible over the network due to misconfiguration. Other setting permit use of the serial port as TERMINAL_SERVER to attach a foreign device for management or to SMART_SENSOR to attach a local hardware extension for use with smart office solutions. "
::= { system 12 }
systemPermitDebugAccess OBJECT-TYPE -- permit_debug_access
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled it is possible to log into the system for debug purposes. This includes telnet/ssh, as well as web and file transfer protocols. To protect the system from unauthorized access it is advised to disable this feature unless instructed by authorized service personnel. NOTE: To ensure that any possibly pending debug access is terminated reboot the device after setting this parameter to disabled."
::= { system 13 }
systemPermitIncomingAlerts OBJECT-TYPE -- permit_incoming_alerts
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled it is possible receive alerts via from external devices via SNMP or HTTP(S). This feature may be used in combination with custom scripting to react to external events. To protect the system from unauthorized spam it is advised to disable this feature unless there is an application for it."
::= { system 14 }
systemCharacterSet OBJECT-TYPE -- character_set
SYNTAX INTEGER
{
iso88591 (1),
iso88595 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter can be set to support languages with characters not found the normal Western European character set. Be sure to set your CLI terminal to the matching setting."
::= { system 15 }
systemConfigurationSaveMode OBJECT-TYPE -- configuration_save_mode
SYNTAX INTEGER
{
permanently (0),
temporarily (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In most cases the configuration of the device should be permanently saved and automatically be applied after a power up. In some cases, however, where public acces to the device is granted it can be desireable to only save changes temporarily. In this mode all configuration changes that occured after setting this mode will be saved in RAM only and will be forgotten on the next system reboot. Important: When this parameter changed to PERMANENTLY all outstanding changes are commited to SD card immediately. When this parameter is changed to temporarily, this already is not saved permanently. Use Management.Files.configuration.commit_config to save this setting before proceeding."
::= { system 16 }
-- ******************* Begin of scriptScheduleTable *************************
scriptScheduleTable OBJECT-TYPE
SYNTAX SEQUENCE OF ScriptScheduleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This dynamic table permits the setup of automated script execution based on precise time scheduling definition. Any number of scripts may be executed at any desired interval or at selected dates. Please ensure the time and date are properly set (via NTP) when using this feature."
::= { system 17 }
scriptScheduleEntry OBJECT-TYPE
SYNTAX ScriptScheduleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { scriptScheduleIndex }
::= { scriptScheduleTable 1 }
ScriptScheduleEntry ::= SEQUENCE {
scriptScheduleIndex INTEGER,
scriptScheduleName DisplayString,
scriptScheduleMode INTEGER ,
scriptScheduleCliScript DisplayString,
scriptScheduleMinutes DisplayString,
scriptScheduleHours DisplayString,
scriptScheduleDays DisplayString,
scriptScheduleMonths DisplayString,
scriptScheduleWeekdays DisplayString
}
scriptScheduleIndex OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Automatically generated"
::= { scriptScheduleEntry 1 }
scriptScheduleName OBJECT-TYPE -- name
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unique name to reference this entry and to remember whose MAC address is entered."
::= { scriptScheduleEntry 2 }
scriptScheduleMode OBJECT-TYPE -- mode
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to disabled this entry is ignored. It is recommended to first set the mode to disabled before the associated time values are modified. When all values are properly set re-enable the entry."
::= { scriptScheduleEntry 3 }
scriptScheduleCliScript OBJECT-TYPE -- cli_script
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enter the name of the cli script that should be executed when the defined time occurs. Ensure that the script name selects a valid file. Several scripts may be assigned, with comma or blank separation."
::= { scriptScheduleEntry 4 }
scriptScheduleMinutes OBJECT-TYPE -- minutes
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Format: 3,14 select exact minutes hour:03 and hour:14. * is every minute. */5 defines every five minutes."
::= { scriptScheduleEntry 5 }
scriptScheduleHours OBJECT-TYPE -- hours
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Format: 0-23. Range and comma separation is permitted. * is every hour."
::= { scriptScheduleEntry 6 }
scriptScheduleDays OBJECT-TYPE -- days
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Format: 1-31. Range and comma separation is permitted. * is every day."
::= { scriptScheduleEntry 7 }
scriptScheduleMonths OBJECT-TYPE -- months
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Format: 1-12 or Jan-Dec. Range and comma separation is permitted. * is every month."
::= { scriptScheduleEntry 8 }
scriptScheduleWeekdays OBJECT-TYPE -- weekdays
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Format: 0-6 or Sun-Sat. Range and comma separation is permitted. * is every day."
::= { scriptScheduleEntry 9 }
-- ********************* End of scriptScheduleTable ***********************
-- ****************************** STATUS SECTION ********************************
systemLastBootTime OBJECT-TYPE -- last_boot_time
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time and date when this device has booted."
::= { system 100 }
systemUptime OBJECT-TYPE -- uptime
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Uptime since last reboot in seconds."
::= { system 101 }
systemUsedMacAddress OBJECT-TYPE -- used_mac_address
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the mac address used by this unit. Usually follows to MAC defined in the factory setting, but may be overwritten by the alternative_mac_address."
::= { system 102 }
systemUsedBootMedia OBJECT-TYPE -- used_boot_media
SYNTAX INTEGER
{
sdCard (0),
internalMemory (1),
nfs (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { system 103 }
systemTemperature OBJECT-TYPE -- temperature
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature value in centigrade."
::= { system 104 }
systemClimateLevel OBJECT-TYPE -- climate_level
SYNTAX INTEGER
{
unknown (0),
criticalLow (1),
low (2),
normal (3),
increased (4),
high (5),
criticalHigh (6),
shutdown (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Annotated temperature level."
::= { system 105 }
-- ******************* Begin of firmwareTable *************************
firmwareTable OBJECT-TYPE
SYNTAX SEQUENCE OF FirmwareEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This section provides details about the running firmware."
::= { system 106 }
firmwareEntry OBJECT-TYPE
SYNTAX FirmwareEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { firmwareIndex }
::= { firmwareTable 1 }
FirmwareEntry ::= SEQUENCE {
firmwareIndex INTEGER,
firmwareRunningVersion DisplayString,
firmwareBuildDate DisplayString,
firmwareBuildNumber Unsigned32
}
firmwareIndex OBJECT-TYPE
SYNTAX INTEGER (0)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Automatically generated"
::= { firmwareEntry 1 }
firmwareRunningVersion OBJECT-TYPE -- running_version
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Running firmware version."
::= { firmwareEntry 2 }
firmwareBuildDate OBJECT-TYPE -- build_date
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Build date of the running firmware. Format: 2012-01-18 12:00:22."
::= { firmwareEntry 3 }
firmwareBuildNumber OBJECT-TYPE -- build_number
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Build number of the running firmware retrieved from the repository."
::= { firmwareEntry 4 }
-- ********************* End of firmwareTable ***********************
-- ******************* Begin of saveInfoTable *************************
saveInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SaveInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This section provided status information about the internal parameter saving process."
::= { system 107 }
saveInfoEntry OBJECT-TYPE
SYNTAX SaveInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { saveInfoIndex }
::= { saveInfoTable 1 }
SaveInfoEntry ::= SEQUENCE {
saveInfoIndex INTEGER,
saveInfoLastSavedParameter DisplayString,
saveInfoSaveMode INTEGER ,
saveInfoWriteStatus INTEGER ,
saveInfoTimeStamp Counter32
}
saveInfoIndex OBJECT-TYPE
SYNTAX INTEGER (0)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Automatically generated"
::= { saveInfoEntry 1 }
saveInfoLastSavedParameter OBJECT-TYPE -- last_saved_parameter
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Records the last written parameter."
::= { saveInfoEntry 2 }
saveInfoSaveMode OBJECT-TYPE -- save_mode
SYNTAX INTEGER
{
permanently (0),
temporarily (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reflects Device.system.configuration_save_mode setting."
::= { saveInfoEntry 3 }
saveInfoWriteStatus OBJECT-TYPE -- write_status
SYNTAX INTEGER
{
nothingToSave (0),
processing (1),
savedToRam (2),
savedToSdcard (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if last parameter was written to SD card or temporary RAM."
::= { saveInfoEntry 4 }
saveInfoTimeStamp OBJECT-TYPE -- time_stamp
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Records the time the write status was last changed."
::= { saveInfoEntry 5 }
-- ********************* End of saveInfoTable ***********************
END