271 lines
7.2 KiB
Plaintext
271 lines
7.2 KiB
Plaintext
-- *****************************************************************
|
|
-- INFINERA-TP-OtdmOtdrPtp-MIB
|
|
--
|
|
-- October 2008, Sharfuddin Syed / Narendra Gupta
|
|
--
|
|
--
|
|
-- Copyright (c) 2008-2012 by Infinera Inc.
|
|
-- All rights reserved.
|
|
-- ****************************************************************
|
|
|
|
INFINERA-TP-OtdmOtdrPtp-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
|
|
ifIndex FROM IF-MIB
|
|
terminationPoint FROM INFINERA-REG-MIB
|
|
FloatHundredths, InfnFiberType FROM INFINERA-TC-MIB
|
|
DisplayString FROM SNMPv2-TC;
|
|
|
|
|
|
otdmOtdrPtpMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201310200000Z"
|
|
ORGANIZATION "Infinera"
|
|
CONTACT-INFO
|
|
"Infinera
|
|
1322 Bordeaux Drive
|
|
Sunnyvale, CA - 94089
|
|
|
|
Contact : Technical Support
|
|
Email : support@infinera.com
|
|
Phone : 1-877-INF-5288"
|
|
DESCRIPTION " "
|
|
REVISION "201310200000Z"
|
|
DESCRIPTION "First Version"
|
|
::= { terminationPoint 48 }
|
|
|
|
otdmOtdrPtpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OtsPTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of otdmOtdrPtp entries. Each entry is uniquely identified by the value of ifIndex."
|
|
::= { otdmOtdrPtpMIB 1 }
|
|
|
|
otdmOtdrPtpEntry OBJECT-TYPE
|
|
SYNTAX OtsPTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
INDEX { ifIndex }
|
|
::= { otdmOtdrPtpTable 1 }
|
|
|
|
|
|
OtsPTPEntry ::= SEQUENCE {
|
|
otdmOtdrPtpConnectivityState INTEGER,
|
|
otdmOtdrPtpLstSuccConnValidationTime Integer32,
|
|
otdmOtdrPtpProvisionedNeighborPtp DisplayString,
|
|
otdmOtdrPtpTestControlStatus INTEGER,
|
|
otdmOtdrPtpTestAquistionMode INTEGER,
|
|
otdmOtdrPtpTestPulseWidth INTEGER,
|
|
otdmOtdrPtpDetectionRange INTEGER,
|
|
otdmOtdrPtpAcquistionTime INTEGER,
|
|
otdmOtdrPtpTestCableID DisplayString,
|
|
otdmOtdrPtpTestFiberID DisplayString,
|
|
otdmOtdrPtpTestFiberType InfnFiberType,
|
|
otdmOtdrPtpTestEventLossThreshold FloatHundredths,
|
|
otdmOtdrPtpTestReflectionThreshold FloatHundredths,
|
|
otdmOtdrPtpTestEndOfFiberThreshold FloatHundredths,
|
|
otdmOtdrPtpTestResultFileName DisplayString,
|
|
otdmOtdrPtpTestResultUpload INTEGER
|
|
}
|
|
|
|
otdmOtdrPtpConnectivityState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notVerified(1),
|
|
valid(2),
|
|
inValid(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 1 }
|
|
|
|
|
|
otdmOtdrPtpLstSuccConnValidationTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 2 }
|
|
|
|
otdmOtdrPtpProvisionedNeighborPtp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 3 }
|
|
|
|
otdmOtdrPtpTestControlStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
inProgress(1),
|
|
queuedUp(2),
|
|
scheduled(3),
|
|
idle(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 4 }
|
|
|
|
otdmOtdrPtpTestAquistionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic(1),
|
|
manual(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 5 }
|
|
|
|
otdmOtdrPtpTestPulseWidth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ns5(1),
|
|
ns10(2),
|
|
ns30(3),
|
|
ns100(4),
|
|
ns300(5),
|
|
us1(6),
|
|
us3(7),
|
|
us10(8),
|
|
us20(9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 6 }
|
|
|
|
otdmOtdrPtpDetectionRange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
km05(1),
|
|
km1(2),
|
|
km2(3),
|
|
km5(4),
|
|
km10(5),
|
|
km20(6),
|
|
km40(7),
|
|
km80(8),
|
|
km160(9),
|
|
km260(10)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 7 }
|
|
|
|
otdmOtdrPtpAcquistionTime OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sec1(1),
|
|
sec5(2),
|
|
sec10(3),
|
|
sec20(4),
|
|
sec30(5),
|
|
sec60(6),
|
|
sec120(7),
|
|
sec180(8),
|
|
sec240(9),
|
|
sec300(10)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 8 }
|
|
|
|
otdmOtdrPtpTestCableID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 9 }
|
|
|
|
otdmOtdrPtpTestFiberID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 10 }
|
|
|
|
otdmOtdrPtpTestFiberType OBJECT-TYPE
|
|
SYNTAX InfnFiberType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 11 }
|
|
|
|
otdmOtdrPtpTestEventLossThreshold OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 12 }
|
|
|
|
otdmOtdrPtpTestReflectionThreshold OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 13 }
|
|
|
|
otdmOtdrPtpTestEndOfFiberThreshold OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 15 }
|
|
|
|
otdmOtdrPtpTestResultFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 16 }
|
|
|
|
otdmOtdrPtpTestResultUpload OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { otdmOtdrPtpEntry 17 }
|
|
|
|
-- Conformance Statements
|
|
otdmOtdrPtpConformance OBJECT IDENTIFIER ::= { otdmOtdrPtpMIB 3 }
|
|
otdmOtdrPtpCompliances OBJECT IDENTIFIER ::= { otdmOtdrPtpConformance 1 }
|
|
otdmOtdrPtpGroups OBJECT IDENTIFIER ::= { otdmOtdrPtpConformance 2 }
|
|
|
|
otdmOtdrPtpCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the requirements for conformance to the otdmOtdrPtp-MIB"
|
|
MODULE
|
|
MANDATORY-GROUPS { otdmOtdrPtpGroup }
|
|
::= { otdmOtdrPtpCompliances 1 }
|
|
|
|
otdmOtdrPtpGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
otdmOtdrPtpConnectivityState,
|
|
otdmOtdrPtpLstSuccConnValidationTime,
|
|
otdmOtdrPtpProvisionedNeighborPtp,
|
|
otdmOtdrPtpTestControlStatus,
|
|
otdmOtdrPtpTestAquistionMode,
|
|
otdmOtdrPtpTestPulseWidth,
|
|
otdmOtdrPtpDetectionRange,
|
|
otdmOtdrPtpAcquistionTime,
|
|
otdmOtdrPtpTestCableID,
|
|
otdmOtdrPtpTestFiberID,
|
|
otdmOtdrPtpTestFiberType,
|
|
otdmOtdrPtpTestEventLossThreshold,
|
|
otdmOtdrPtpTestReflectionThreshold,
|
|
otdmOtdrPtpTestEndOfFiberThreshold,
|
|
otdmOtdrPtpTestResultFileName,
|
|
otdmOtdrPtpTestResultUpload
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A collection of objects for managing the otdmOtdrPtp"
|
|
::= { otdmOtdrPtpGroups 1 }
|
|
END
|