-- INFINERA-PM-GROUPTP-MIB
--
-- October 2008, Sharfuddin Syed / Narendra Gupta
--
--
-- Copyright (c) 2008-2012 by Infinera Inc.
-- All rights reserved.
-- ****************************************************************
INFINERA-PM-GROUPTP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, Counter64 FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
DisplayString, TruthValue FROM SNMPv2-TC
ifIndex FROM IF-MIB
HCPerfIntervalCount FROM HC-PerfHist-TC-MIB
perfMon FROM INFINERA-REG-MIB;
groupTpPmMIB MODULE-IDENTITY
LAST-UPDATED "200810200000Z"
ORGANIZATION "Infinera"
CONTACT-INFO
"Infinera
1322 Bordeaux Drive
Sunnyvale, CA - 94089
Contact : Technical Support
Email : support@infinera.com
Phone : 1-877-INF-5288"
DESCRIPTION
" "
REVISION "200810200000Z"
DESCRIPTION
"First Version"
::= { perfMon 9 }
groupTpPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF GroupTpPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of GroupTpPm entries. Each entry is uniquely identified by the value of ifIndex, sampleDuration and groupTpPmTimestamp."
::= { groupTpPmMIB 2 }
groupTpPmEntry OBJECT-TYPE
SYNTAX GroupTpPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A GroupTp entry containing historical performance information pertaining to Infinera GroupTp interfaces.
This table is a subclass of IfCommon. Entries will exist in this table only for interfaces of type GroupTp.
Each interface may have a number of entries in this table, each with a different combination
of timestamp and sample duration."
INDEX { ifIndex, groupTpPmSampleDuration, groupTpPmTimestamp }
::= { groupTpPmTable 1 }
GroupTpPmEntry ::= SEQUENCE {
groupTpPmTimestamp Integer32,
groupTpPmSampleDuration INTEGER,
groupTpPmValidity TruthValue,
groupTpPmDtpRxCV HCPerfIntervalCount,
groupTpPmDtpRxES Integer32,
groupTpPmDtpRxSES Integer32,
groupTpPmDtpRxUAS Integer32,
groupTpPmDtpTxCV HCPerfIntervalCount,
groupTpPmDtpTxES Integer32,
groupTpPmDtpTxSES Integer32,
groupTpPmDtpTxUAS Integer32
}
groupTpPmTimestamp OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"End Time stamp for this interval. If this time is later than the current time,
then the data for this bucket is currently being collected."
::= { groupTpPmEntry 1 }
groupTpPmSampleDuration OBJECT-TYPE
SYNTAX INTEGER {
fifteenMinutes(1),
day(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The duration of this sample."
::= { groupTpPmEntry 2 }
groupTpPmValidity OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Flag indicating if data was valid for the entire interval"
::= { groupTpPmEntry 3 }
groupTpPmDtpRxCV OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Received Code Violations."
::= { groupTpPmEntry 4 }
groupTpPmDtpRxES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Errored Seconds"
::= { groupTpPmEntry 5 }
groupTpPmDtpRxSES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received Severely Errored Seconds"
::= { groupTpPmEntry 6 }
groupTpPmDtpRxUAS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DTF Path Layer Unavailable Seconds."
::= { groupTpPmEntry 7 }
groupTpPmDtpTxCV OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Transmitted Code Violations"
::= { groupTpPmEntry 8 }
groupTpPmDtpTxES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted Errored Seconds"
::= { groupTpPmEntry 9 }
groupTpPmDtpTxSES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted Severely Errored Seconds"
::= { groupTpPmEntry 10 }
groupTpPmDtpTxUAS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DTF Path Layer Unavailable Seconds."
::= { groupTpPmEntry 11 }
groupTpPmRealTable OBJECT-TYPE
SYNTAX SEQUENCE OF GroupTpPmRealEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of GroupTpPmReal entries. Each entry is uniquely identified by the value of ifIndex."
::= { groupTpPmMIB 1 }
groupTpPmRealEntry OBJECT-TYPE
SYNTAX GroupTpPmRealEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A GroupTp entry containing real-time performance information pertaining to Infinera GroupTp interfaces.
This table is a subclass of IfCommon. Entries will exist in this table only for interfaces of type GroupTp."
INDEX { ifIndex }
::= { groupTpPmRealTable 1 }
GroupTpPmRealEntry ::= SEQUENCE {
groupTpPmRealDtpRxCV Counter64,
groupTpPmRealDtpRxES Integer32,
groupTpPmRealDtpRxSES Integer32,
groupTpPmRealDtpRxUAS Integer32,
groupTpPmRealDtpTxCV Counter64,
groupTpPmRealDtpTxES Integer32,
groupTpPmRealDtpTxSES Integer32,
groupTpPmRealDtpTxUAS Integer32
}
groupTpPmRealDtpRxCV OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Code Violations"
::= { groupTpPmRealEntry 1 }
groupTpPmRealDtpRxES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Errored Seconds"
::= { groupTpPmRealEntry 2 }
groupTpPmRealDtpRxSES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Severely Errored Seconds"
::= { groupTpPmRealEntry 3 }
groupTpPmRealDtpRxUAS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "DtpUAS"
::= { groupTpPmRealEntry 4 }
groupTpPmRealDtpTxCV OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Transmitted Code Violations"
::= { groupTpPmRealEntry 5 }
groupTpPmRealDtpTxES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Transmitted Errored Seconds"
::= { groupTpPmRealEntry 6 }
groupTpPmRealDtpTxSES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Transmitted Severely Errored Seconds"
::= { groupTpPmRealEntry 7 }
groupTpPmRealDtpTxUAS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "DtpTxUAS"
::= { groupTpPmRealEntry 8 }
-- Conformance Statements
groupTpPmConformance OBJECT IDENTIFIER ::= { groupTpPmMIB 3 }
groupTpPmCompliances OBJECT IDENTIFIER ::= { groupTpPmConformance 1 }
groupTpPmGroups OBJECT IDENTIFIER ::= { groupTpPmConformance 2 }
groupTpPmCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the PM-GROUPTP-MIB"
MODULE
MANDATORY-GROUPS { groupTpPmGroup }
::= { groupTpPmCompliances 1 }
groupTpPmRealCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the groupTpPmReal-MIB"
MODULE
MANDATORY-GROUPS { groupTpPmRealGroup }
::= { groupTpPmCompliances 2 }
groupTpPmGroup OBJECT-GROUP
OBJECTS {
groupTpPmValidity,
groupTpPmDtpRxCV,
groupTpPmDtpRxES,
groupTpPmDtpRxSES,
groupTpPmDtpRxUAS,
groupTpPmDtpTxCV,
groupTpPmDtpTxES,
groupTpPmDtpTxSES,
groupTpPmDtpTxUAS
}
STATUS current
DESCRIPTION
" A collection of objects for reading the performance of the groupTp."
::= { groupTpPmGroups 1 }
groupTpPmRealGroup OBJECT-GROUP
OBJECTS {
groupTpPmRealDtpRxCV,
groupTpPmRealDtpRxES,
groupTpPmRealDtpRxSES,
groupTpPmRealDtpRxUAS,
groupTpPmRealDtpTxCV,
groupTpPmRealDtpTxES,
groupTpPmRealDtpTxSES,
groupTpPmRealDtpTxUAS
}
STATUS current
DESCRIPTION
" A collection of objects for reading the real-time performance of the groupTp."
::= { groupTpPmGroups 2 }
END