-- INFINERA-ENTITY-CHASSIS-MIB
|
|
--
|
|
-- October 2008, Sharfuddin Syed / Narendra Gupta
|
|
--
|
|
--
|
|
-- Copyright (c) 2008-2012 by Infinera Inc.
|
|
-- All rights reserved.
|
|
-- ****************************************************************
|
|
|
|
INFINERA-ENTITY-CHASSIS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY, Integer32, Unsigned32 FROM SNMPv2-SMI
|
|
OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF
|
|
RowStatus, DisplayString, TruthValue FROM SNMPv2-TC
|
|
entLPPhysicalIndex FROM ENTITY-MIB
|
|
equipment FROM INFINERA-REG-MIB
|
|
FloatThousandths, FloatHundredths,
|
|
FloatArbitraryPrecision,
|
|
FloatTenths, InfnChassisType, InfnPmHistStatsControl,
|
|
InfnChassisSwitchingMode, InfnEnableDisable FROM INFINERA-TC-MIB;
|
|
|
|
chassisMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200810200000Z"
|
|
ORGANIZATION
|
|
"INFINERA"
|
|
CONTACT-INFO
|
|
"Infinera
|
|
169 Java Drive
|
|
Sunnyvale, CA - 94089
|
|
|
|
Contact : Technical Support
|
|
Email : support@infinera.com
|
|
Phone : 1-877-INF-5288"
|
|
DESCRIPTION
|
|
"This MIB is modeling for CHASSIS equipment table."
|
|
|
|
::= { equipment 13 }
|
|
|
|
chassisConformance OBJECT IDENTIFIER ::= { chassisMIB 3 }
|
|
chassisCompliances OBJECT IDENTIFIER ::= { chassisConformance 1 }
|
|
chassisGroups OBJECT IDENTIFIER ::= { chassisConformance 2 }
|
|
|
|
chassisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ChassisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains all chassis modules that are currently present in a network element."
|
|
::= { chassisMIB 1 }
|
|
|
|
chassisEntry OBJECT-TYPE
|
|
SYNTAX ChassisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the CHASSIS table. Each row in the table is identified with a unique entPhysicalIndexID.
|
|
"
|
|
INDEX { entLPPhysicalIndex }
|
|
::= { chassisTable 1 }
|
|
|
|
ChassisEntry ::= SEQUENCE {
|
|
chassisMoId DisplayString,
|
|
chassisProvChassisType InfnChassisType,
|
|
chassisInstalledChassisType InfnChassisType,
|
|
chassisProvSerialNumber DisplayString,
|
|
chassisInstalledSerialNumber DisplayString,
|
|
chassisRackName DisplayString,
|
|
chassisRUlocationInRack Unsigned32,
|
|
chassisSwitchCapabilityMode INTEGER,
|
|
chassisInletTemperature FloatArbitraryPrecision,
|
|
chassisAcoState INTEGER,
|
|
chassisBayLevelSummaryAlarmReporting INTEGER,
|
|
chassisConfiguredMaxPowerDraw FloatThousandths,
|
|
chassisCurrentEstimatedPowerDraw FloatThousandths,
|
|
chassisEqptMaxPowerDraw FloatHundredths,
|
|
chassisScmMigrationAllowed TruthValue,
|
|
chassisScmMigrationInProgress TruthValue,
|
|
chassisPowerControl INTEGER,
|
|
chassiscurrentInstalledPowerDraw FloatThousandths,
|
|
chassisConfiguredPemRating Unsigned32,
|
|
chassisRowStatus RowStatus,
|
|
chassisIsNCChassis TruthValue,
|
|
chassisSwitchingMode InfnChassisSwitchingMode,
|
|
chassisMaxAvailablePower FloatThousandths,
|
|
chassisActvTimingSource DisplayString,
|
|
chassisConfiguredAmbientTemp Unsigned32,
|
|
chassisSkewBudget INTEGER,
|
|
chassisOperatingTemperatureThreshold Integer32,
|
|
chassisPduCktBreakerRating FloatArbitraryPrecision,
|
|
chassisRebootTime Integer32,
|
|
chassisCLEI DisplayString,
|
|
chassisHardwareVersion DisplayString,
|
|
chassisManufacturedDate DisplayString,
|
|
chassisPartNumber DisplayString,
|
|
chassisPON DisplayString,
|
|
chassisHolderType INTEGER,
|
|
chassisHolderState INTEGER,
|
|
chassisAcceptableEquipmentTypeList DisplayString,
|
|
chassisUnreachableFromManagement TruthValue,
|
|
chassisSerialPortCLIAccess InfnEnableDisable,
|
|
chassisAcliSessionAdminState InfnEnableDisable,
|
|
chassisFruInsertionDate DisplayString,
|
|
chassisPowerSupplyType INTEGER,
|
|
chassisBaffleType INTEGER,
|
|
chassisPmHistStatsEnable InfnPmHistStatsControl,
|
|
chassisInletTemperatureOffset FloatTenths,
|
|
chassisHasPluggableEeprom TruthValue,
|
|
chassisPluggablePromSerialNumber DisplayString,
|
|
chassisOutletTemperature FloatArbitraryPrecision,
|
|
chassisTTLMax Integer32,
|
|
chassisTTLCurrentDays Integer32
|
|
}
|
|
|
|
|
|
chassisMoId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the primary Key of the objects e.g 1, 2, 3..."
|
|
::= { chassisEntry 1 }
|
|
|
|
chassisProvChassisType OBJECT-TYPE
|
|
SYNTAX InfnChassisType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The provisioned chassis. Valid values: OTC, DTC, DTC-A, DTC-B, and MTC-A."
|
|
::= { chassisEntry 2 }
|
|
|
|
chassisInstalledChassisType OBJECT-TYPE
|
|
SYNTAX InfnChassisType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The installed chassis type."
|
|
::= { chassisEntry 3 }
|
|
|
|
chassisProvSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The provisioned serial number of the Expansion Chassis.
|
|
This field is configured for the expansion chassis in a multi-chassis
|
|
configuration. This attribute can be modified only when the Admin State
|
|
of the chassis (Expansion Chassis only) is Locked."
|
|
::= { chassisEntry 4 }
|
|
|
|
chassisInstalledSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual serial number of the chassis"
|
|
::= { chassisEntry 5 }
|
|
|
|
chassisRackName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the rack in which the chassis is installed."
|
|
::= { chassisEntry 6 }
|
|
|
|
chassisRUlocationInRack OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The position of the chassis within the rack. The chassis with lower
|
|
RU location is displayed at the bottom in the node view and the one
|
|
with higher number is displayed at the top. If there are more than two
|
|
chassis having the same rack name, they are displayed next to each
|
|
other though they might be physically located in the same rack."
|
|
::= { chassisEntry 7 }
|
|
|
|
chassisSwitchCapabilityMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ring (1),
|
|
mesh (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The switch capability mode for the chassis. Valid values: ring and mesh."
|
|
::= { chassisEntry 8 }
|
|
|
|
chassisInletTemperature OBJECT-TYPE
|
|
SYNTAX FloatArbitraryPrecision
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature (in Centigrade) of the circuit pack at the inlet.
|
|
The temperature is displayed as -1 if the circuit pack does not have
|
|
a temperature sensor."
|
|
::= { chassisEntry 9 }
|
|
|
|
chassisAcoState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis alarm cutoff state."
|
|
::= { chassisEntry 10 }
|
|
|
|
chassisBayLevelSummaryAlarmReporting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flag that enables reporting of bay-level alarms. Typically, this is
|
|
enabled for one chassis within a bay and disabled for all other chassis
|
|
in the same bay. Vaid values:enabled and disabled."
|
|
::= { chassisEntry 11 }
|
|
|
|
chassisConfiguredMaxPowerDraw OBJECT-TYPE
|
|
SYNTAX FloatThousandths
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The estimated power drawn by the chassis. This varies depending on the
|
|
type of the chassis and associated configuration."
|
|
::= { chassisEntry 12 }
|
|
|
|
chassisCurrentEstimatedPowerDraw OBJECT-TYPE
|
|
SYNTAX FloatThousandths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sum of estimated power drawn by all the currently installed and
|
|
pre-provisioned FRUs in the chassis. This value is not indicative of
|
|
the actual power drawn."
|
|
::= { chassisEntry 13 }
|
|
|
|
chassisEqptMaxPowerDraw OBJECT-TYPE
|
|
SYNTAX FloatHundredths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The estimated power drawn by the chassis. This varies depending on the
|
|
type of the chassis and associated configuration."
|
|
::= { chassisEntry 14 }
|
|
|
|
chassisScmMigrationAllowed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects indicate whether user can chnage the chassisSwitchCapabilityMode.
|
|
If this is false user will not be able to chnage."
|
|
::= { chassisEntry 15 }
|
|
|
|
chassisScmMigrationInProgress OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects indicate that switch capability mode change is in
|
|
progress."
|
|
::= { chassisEntry 16 }
|
|
|
|
chassisPowerControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects enable the auto power saving if pwoer is hitting the limit."
|
|
::= { chassisEntry 17 }
|
|
|
|
chassiscurrentInstalledPowerDraw OBJECT-TYPE
|
|
SYNTAX FloatThousandths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The estimated power drawn by the installed equipment in chassis.
|
|
This varies depending on the type of the chassis and installed equipment."
|
|
::= { chassisEntry 18 }
|
|
|
|
chassisConfiguredPemRating OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute tells what is the compatible PEM rating for the chassis
|
|
, in case of PEM-35 this attribute should be set to 35 and in case
|
|
of PEM-70 it should be set to 70. Accordingly RatingAmps attribute of PEM
|
|
will change and in case RatingAmps value of PEM doesn't matche with
|
|
its InstalledRatingAmps then equipment mismatch alarm will be raised."
|
|
::= { chassisEntry 19 }
|
|
|
|
chassisRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status of this CHASSIS entry.
|
|
Because rows in this table are indexed by entPhysicalIndex, to create a new row one must
|
|
choose a value of entPhysicalIndex that is not already in use.
|
|
|
|
A side-effect of the creation of a row in this table is the creation of a corresponding
|
|
row in the eqptTable and the entPhysicalTable.
|
|
|
|
The status may not be set to active if the chassisMoId, chassisProvEqptType and other
|
|
read-create objects are not set to valid values.
|
|
|
|
This row may only be deleted if it was a pre-provisioned row and the hardware is not present.
|
|
|
|
If this row is deleted, the associated row in the Eqpt Table and entPhysicalTable will be
|
|
deleted by the agent."
|
|
::= { chassisEntry 20 }
|
|
|
|
chassisIsNCChassis OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"whether or not this
|
|
chassis houses the Node Controller XCM."
|
|
::= { chassisEntry 21 }
|
|
|
|
chassisSwitchingMode OBJECT-TYPE
|
|
SYNTAX InfnChassisSwitchingMode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"current configuration of the chassis
|
|
switch fabric module."
|
|
::= { chassisEntry 22 }
|
|
|
|
chassisMaxAvailablePower OBJECT-TYPE
|
|
SYNTAX FloatThousandths
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum available
|
|
power in the chassis"
|
|
::= { chassisEntry 23 }
|
|
|
|
chassisActvTimingSource OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 24 }
|
|
|
|
chassisOperatingTemperatureThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 25 }
|
|
|
|
chassisConfiguredAmbientTemp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 26 }
|
|
|
|
|
|
chassisSkewBudget OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
low (2),
|
|
high (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 27 }
|
|
|
|
chassisPduCktBreakerRating OBJECT-TYPE
|
|
SYNTAX FloatArbitraryPrecision
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 28 }
|
|
|
|
chassisRebootTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 29 }
|
|
|
|
chassisCLEI OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 30 }
|
|
|
|
chassisHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 31 }
|
|
|
|
chassisManufacturedDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 32 }
|
|
|
|
chassisPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 33 }
|
|
|
|
chassisPON OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 34 }
|
|
|
|
chassisHolderType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
chassis(1),
|
|
self(2),
|
|
slot(3),
|
|
subSlot(4),
|
|
unknown (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 35 }
|
|
|
|
chassisHolderState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
empty (1),
|
|
plugIn(2),
|
|
installed(3),
|
|
installedAndExpected(4),
|
|
mismatchOfInstalledAndExpected(5),
|
|
unknown(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 36 }
|
|
|
|
chassisAcceptableEquipmentTypeList OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 37 }
|
|
|
|
chassisUnreachableFromManagement OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 38 }
|
|
|
|
chassisSerialPortCLIAccess OBJECT-TYPE
|
|
SYNTAX InfnEnableDisable
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 39}
|
|
|
|
chassisAcliSessionAdminState OBJECT-TYPE
|
|
SYNTAX InfnEnableDisable
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 40 }
|
|
|
|
chassisFruInsertionDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 41 }
|
|
|
|
chassisPowerSupplyType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
native(1),
|
|
unmanaged3rdparty(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 42 }
|
|
|
|
chassisBaffleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
mtc9AirBaffle(2),
|
|
mtc9AirBaffle2(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 43 }
|
|
|
|
chassisPmHistStatsEnable OBJECT-TYPE
|
|
SYNTAX InfnPmHistStatsControl
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 44 }
|
|
|
|
chassisInletTemperatureOffset OBJECT-TYPE
|
|
SYNTAX FloatTenths
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inlet Temperature Offset"
|
|
::= { chassisEntry 45 }
|
|
|
|
chassisHasPluggableEeprom OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flag to indicate if the device has pluggable Eeprom"
|
|
::= { chassisEntry 46 }
|
|
|
|
chassisPluggablePromSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Plugged in Eeprom serial number"
|
|
::= { chassisEntry 47 }
|
|
|
|
chassisOutletTemperature OBJECT-TYPE
|
|
SYNTAX FloatArbitraryPrecision
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outlet temperature of the chassis"
|
|
::= { chassisEntry 48 }
|
|
|
|
chassisTTLMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 49 }
|
|
|
|
chassisTTLCurrentDays OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { chassisEntry 50 }
|
|
|
|
chassisCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
MODULE
|
|
MANDATORY-GROUPS { chassisGroup }
|
|
::= { chassisCompliances 1 }
|
|
|
|
|
|
|
|
|
|
chassisGroup OBJECT-GROUP
|
|
OBJECTS { chassisMoId,
|
|
chassisProvChassisType,
|
|
chassisInstalledChassisType,
|
|
chassisProvSerialNumber,
|
|
chassisInstalledSerialNumber,
|
|
chassisRackName,
|
|
chassisRUlocationInRack,
|
|
chassisSwitchCapabilityMode,
|
|
chassisInletTemperature,
|
|
chassisAcoState,
|
|
chassisBayLevelSummaryAlarmReporting,
|
|
chassisConfiguredMaxPowerDraw,
|
|
chassisCurrentEstimatedPowerDraw,
|
|
chassisEqptMaxPowerDraw,
|
|
chassisScmMigrationAllowed,
|
|
chassisScmMigrationInProgress,
|
|
chassisPowerControl,
|
|
chassiscurrentInstalledPowerDraw,
|
|
chassisConfiguredPemRating,
|
|
chassisRowStatus,
|
|
chassisIsNCChassis,
|
|
chassisSwitchingMode,
|
|
chassisMaxAvailablePower,
|
|
chassisActvTimingSource,
|
|
chassisOperatingTemperatureThreshold,
|
|
chassisConfiguredAmbientTemp,
|
|
chassisSkewBudget,
|
|
chassisPduCktBreakerRating,
|
|
chassisRebootTime ,
|
|
chassisCLEI ,
|
|
chassisHardwareVersion ,
|
|
chassisManufacturedDate ,
|
|
chassisPartNumber ,
|
|
chassisPON ,
|
|
chassisHolderType ,
|
|
chassisHolderState ,
|
|
chassisAcceptableEquipmentTypeList,
|
|
chassisUnreachableFromManagement ,
|
|
chassisSerialPortCLIAccess ,
|
|
chassisAcliSessionAdminState ,
|
|
chassisFruInsertionDate ,
|
|
chassisPowerSupplyType ,
|
|
chassisBaffleType ,
|
|
chassisPmHistStatsEnable,
|
|
chassisInletTemperatureOffset,
|
|
chassisHasPluggableEeprom,
|
|
chassisPluggablePromSerialNumber,
|
|
chassisOutletTemperature,
|
|
chassisTTLMax,
|
|
chassisTTLCurrentDays
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { chassisGroups 1 }
|
|
END
|