11617 lines
456 KiB
Plaintext
11617 lines
456 KiB
Plaintext
|
||
-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 2014.
|
||
--
|
||
-- LaserJet 570 Printer Model Specific MIB.
|
||
--
|
||
-- Generated on Jun. 05, 2014.
|
||
--
|
||
-- Company names and product names mentioned herein may be
|
||
-- trademarks, and/or registered trademarks of their respective
|
||
-- companies.
|
||
--
|
||
-- For internal and external use.
|
||
--
|
||
-- This MIB describes all the printer model specific
|
||
-- objects supported by the LaserJet 570 printer
|
||
-- when networked connected.
|
||
--
|
||
-- The following MIBs also contain objects supported
|
||
-- by a LaserJet 570 printer:
|
||
--
|
||
-- IEEE 802.11 MIB
|
||
-- IEEE 802.1X MIB
|
||
-- rfc 2790 Host Resources MIB
|
||
-- rfc 3411 SNMP Framework MIB
|
||
-- rfc 3412 SNMP MPD MIB
|
||
-- rfc 3418 SNMP MIB
|
||
-- rfc 3805 Printer MIB
|
||
-- rfc 4022 TCP MIB
|
||
-- rfc 4293 IP MIB
|
||
-- rfc 4113 UDP MIB
|
||
-- PWG 5107.1-2005 Printer Port Monitor MIB
|
||
--
|
||
-- This MIB complies with the following RFCs:
|
||
--
|
||
-- rfc 1157 Simple Network Management Protocol
|
||
-- rfc 2578 Structure of Management Information Version 2
|
||
--
|
||
-- Notes:
|
||
--
|
||
-- 1) Objects containing a string which are defined in this MIB use the
|
||
-- first two bytes to hold the symbol set used to encode the string.
|
||
-- The Roman-8 symbol set has a hex encoding of 0x0115. Other
|
||
-- symbol sets are listed in the PCL 5 Comparison Guide in table
|
||
-- C-1 Symbol Set Values.
|
||
--
|
||
-- 2) Some of the objects included are only supported if an accessory
|
||
-- is installed. These accessories include:
|
||
-- MIO based accessories
|
||
-- SIMM based accessories
|
||
-- Paper handling accessories
|
||
|
||
LJ570-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
OBJECT-TYPE
|
||
FROM RFC-1212
|
||
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
hpPrintServer OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 11}
|
||
dm OBJECT IDENTIFIER ::= { hpPrintServer nm(2) hpsystem(3) net-peripheral(9) netdm(4) 2}
|
||
|
||
device OBJECT IDENTIFIER ::= { dm 1 }
|
||
system OBJECT IDENTIFIER ::= { device 1 }
|
||
settings-system OBJECT IDENTIFIER ::= { system 1 }
|
||
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
|
||
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
|
||
settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 }
|
||
marking-agent-density OBJECT IDENTIFIER ::= { settings-prt-eng 9 }
|
||
status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 }
|
||
marking-agent OBJECT IDENTIFIER ::= { print-engine 5 }
|
||
settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 }
|
||
print-engine-test OBJECT IDENTIFIER ::= { print-engine 9 }
|
||
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
|
||
scanner OBJECT IDENTIFIER ::= { source-subsystem 2 }
|
||
status-scanner OBJECT IDENTIFIER ::= { scanner 2 }
|
||
copier OBJECT IDENTIFIER ::= { device 5 }
|
||
settings-copier OBJECT IDENTIFIER ::= { copier 1 }
|
||
status-system OBJECT IDENTIFIER ::= { system 2 }
|
||
id OBJECT IDENTIFIER ::= { system 3 }
|
||
job OBJECT IDENTIFIER ::= { system 6 }
|
||
settings-job OBJECT IDENTIFIER ::= { job 1 }
|
||
fax-job-control OBJECT IDENTIFIER ::= { job 3 }
|
||
settings-fax-job OBJECT IDENTIFIER ::= { fax-job-control 1 }
|
||
status-fax-job OBJECT IDENTIFIER ::= { fax-job-control 2 }
|
||
faxjob OBJECT IDENTIFIER ::= { fax-job-control 3 }
|
||
faxjob-rx-status OBJECT IDENTIFIER ::= { faxjob 1 }
|
||
faxjob-tx-status OBJECT IDENTIFIER ::= { faxjob 3 }
|
||
faxjob-tx-error OBJECT IDENTIFIER ::= { faxjob 4 }
|
||
faxjob-tx-current-page OBJECT IDENTIFIER ::= { faxjob 5 }
|
||
faxjob-rx-current-page OBJECT IDENTIFIER ::= { faxjob 6 }
|
||
faxjob-rx-duration OBJECT IDENTIFIER ::= { faxjob 7 }
|
||
faxjob-tx-duration OBJECT IDENTIFIER ::= { faxjob 8 }
|
||
fax-activity-log OBJECT IDENTIFIER ::= { job 4 }
|
||
settings-faxlog OBJECT IDENTIFIER ::= { fax-activity-log 1 }
|
||
phone OBJECT IDENTIFIER ::= { system 9 }
|
||
dial OBJECT IDENTIFIER ::= { phone 1 }
|
||
dial-all-lines OBJECT IDENTIFIER ::= { dial 1 }
|
||
answer OBJECT IDENTIFIER ::= { phone 2 }
|
||
answer-all-lines OBJECT IDENTIFIER ::= { answer 1 }
|
||
fax-receive OBJECT IDENTIFIER ::= { source-subsystem 3 }
|
||
settings-fax-receive OBJECT IDENTIFIER ::= { fax-receive 1 }
|
||
status-fax-receive OBJECT IDENTIFIER ::= { fax-receive 2 }
|
||
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
|
||
fax-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 7 }
|
||
settings-fax-proc-sub OBJECT IDENTIFIER ::= { fax-proc-sub 1 }
|
||
status-fax-proc-sub OBJECT IDENTIFIER ::= { fax-proc-sub 2 }
|
||
fax-forwarding OBJECT IDENTIFIER ::= { fax-proc-sub 3 }
|
||
fax-send OBJECT IDENTIFIER ::= { destination-subsystem 2 }
|
||
settings-fax-send OBJECT IDENTIFIER ::= { fax-send 1 }
|
||
status-fax-send OBJECT IDENTIFIER ::= { fax-send 2 }
|
||
transmit-fax OBJECT IDENTIFIER ::= { fax-send 5 }
|
||
hrm OBJECT IDENTIFIER ::= { dm 3 }
|
||
hrStorage OBJECT IDENTIFIER ::= { hrm 2 }
|
||
hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 }
|
||
hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 }
|
||
hrDevice OBJECT IDENTIFIER ::= { hrm 3 }
|
||
hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 }
|
||
hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 }
|
||
hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 }
|
||
hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 }
|
||
iso OBJECT IDENTIFIER ::= { dm 1 }
|
||
org OBJECT IDENTIFIER ::= { iso 3 }
|
||
dod OBJECT IDENTIFIER ::= { org 6 }
|
||
internet OBJECT IDENTIFIER ::= { dod 1 }
|
||
private OBJECT IDENTIFIER ::= { internet 4 }
|
||
enterprises OBJECT IDENTIFIER ::= { private 1 }
|
||
nm OBJECT IDENTIFIER ::= { hpPrintServer 2 }
|
||
interface OBJECT IDENTIFIER ::= { nm 4 }
|
||
npCard OBJECT IDENTIFIER ::= { interface 3 }
|
||
npCRCTable OBJECT IDENTIFIER ::= { npCard 15 }
|
||
npCRCEntry OBJECT IDENTIFIER ::= { npCRCTable 1 }
|
||
inetTrap OBJECT IDENTIFIER ::= { npCard 22 }
|
||
inetTrapDestination OBJECT IDENTIFIER ::= { inetTrap 1 }
|
||
inetTrapDestinationTable OBJECT IDENTIFIER ::= { inetTrapDestination 2 }
|
||
inetTrapDestinationEntry OBJECT IDENTIFIER ::= { inetTrapDestinationTable 1 }
|
||
trap OBJECT IDENTIFIER ::= { nm 13 }
|
||
trapDest OBJECT IDENTIFIER ::= { trap 1 }
|
||
trapFQDNTable OBJECT IDENTIFIER ::= { trapDest 7 }
|
||
trapFQDNEntry OBJECT IDENTIFIER ::= { trapFQDNTable 1 }
|
||
snmpAccess OBJECT IDENTIFIER ::= { nm 15 }
|
||
community OBJECT IDENTIFIER ::= { snmpAccess 1 }
|
||
npSys OBJECT IDENTIFIER ::= { npCard 1 }
|
||
npConns OBJECT IDENTIFIER ::= { npCard 4 }
|
||
npCfg OBJECT IDENTIFIER ::= { npCard 5 }
|
||
npCfgAccessListTable OBJECT IDENTIFIER ::= { npCfg 9 }
|
||
npCfgAccessListEntry OBJECT IDENTIFIER ::= { npCfgAccessListTable 1 }
|
||
npTcp OBJECT IDENTIFIER ::= { npCard 6 }
|
||
npCtl OBJECT IDENTIFIER ::= { npCard 7 }
|
||
npPort OBJECT IDENTIFIER ::= { npCard 13 }
|
||
npDhcp OBJECT IDENTIFIER ::= { npCard 16 }
|
||
npWeb OBJECT IDENTIFIER ::= { npCard 18 }
|
||
npSecurity OBJECT IDENTIFIER ::= { npCard 20 }
|
||
npSecurityDot11EncryptedWEPKeyTable OBJECT IDENTIFIER ::= { npSecurity 7 }
|
||
npSecurityDot11EncryptedWEPKeyEntry OBJECT IDENTIFIER ::= { npSecurityDot11EncryptedWEPKeyTable 1 }
|
||
npSecurityDot11SSIDTable OBJECT IDENTIFIER ::= { npSecurity 9 }
|
||
npSecurityDot11SSIDEntry OBJECT IDENTIFIER ::= { npSecurityDot11SSIDTable 1 }
|
||
system OBJECT IDENTIFIER ::= { nm 3 }
|
||
netPeripheral OBJECT IDENTIFIER ::= { system 9 }
|
||
netPrinter OBJECT IDENTIFIER ::= { netPeripheral 1 }
|
||
generalDeviceStatus OBJECT IDENTIFIER ::= { netPrinter 1 }
|
||
netPML OBJECT IDENTIFIER ::= { netPeripheral 4 }
|
||
netPMLtrap OBJECT IDENTIFIER ::= { netPML 1 }
|
||
npNpi OBJECT IDENTIFIER ::= { npCard 8 }
|
||
npNpiPeripheralAttributeEntry OBJECT IDENTIFIER ::= { npNpi 3 }
|
||
npNpiCardAttributeEntry OBJECT IDENTIFIER ::= { npNpi 4 }
|
||
gdStatusEntry OBJECT IDENTIFIER ::= { generalDeviceStatus 2 }
|
||
photo-job OBJECT IDENTIFIER ::= { job 8 }
|
||
settings-photo-job OBJECT IDENTIFIER ::= { photo-job 3 }
|
||
device-configure OBJECT IDENTIFIER ::= { settings-system 32 }
|
||
display OBJECT IDENTIFIER ::= { status-system 20 }
|
||
display-status OBJECT IDENTIFIER ::= { display 1 }
|
||
interface OBJECT IDENTIFIER ::= { system 4 }
|
||
simm OBJECT IDENTIFIER ::= { interface 1 }
|
||
simm1 OBJECT IDENTIFIER ::= { simm 1 }
|
||
usb-interface OBJECT IDENTIFIER ::= { interface 9 }
|
||
usb OBJECT IDENTIFIER ::= { usb-interface 2 }
|
||
test OBJECT IDENTIFIER ::= { system 5 }
|
||
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
|
||
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
|
||
job-info OBJECT IDENTIFIER ::= { job 5 }
|
||
job-info-attribute OBJECT IDENTIFIER ::= { job-info 23 }
|
||
errorlog OBJECT IDENTIFIER ::= { system 11 }
|
||
error1 OBJECT IDENTIFIER ::= { errorlog 1 }
|
||
error2 OBJECT IDENTIFIER ::= { errorlog 2 }
|
||
error3 OBJECT IDENTIFIER ::= { errorlog 3 }
|
||
error4 OBJECT IDENTIFIER ::= { errorlog 4 }
|
||
error5 OBJECT IDENTIFIER ::= { errorlog 5 }
|
||
error6 OBJECT IDENTIFIER ::= { errorlog 6 }
|
||
error7 OBJECT IDENTIFIER ::= { errorlog 7 }
|
||
error8 OBJECT IDENTIFIER ::= { errorlog 8 }
|
||
error9 OBJECT IDENTIFIER ::= { errorlog 9 }
|
||
error10 OBJECT IDENTIFIER ::= { errorlog 10 }
|
||
firmware-download OBJECT IDENTIFIER ::= { system 18 }
|
||
io OBJECT IDENTIFIER ::= { source-subsystem 1 }
|
||
settings-io OBJECT IDENTIFIER ::= { io 1 }
|
||
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
|
||
settings-pdl OBJECT IDENTIFIER ::= { pdl 1 }
|
||
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
|
||
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
|
||
pdl-pclxl OBJECT IDENTIFIER ::= { pdl 16 }
|
||
pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 }
|
||
intray OBJECT IDENTIFIER ::= { print-engine 3 }
|
||
settings-intray OBJECT IDENTIFIER ::= { intray 1 }
|
||
intrays OBJECT IDENTIFIER ::= { intray 3 }
|
||
intray1 OBJECT IDENTIFIER ::= { intrays 1 }
|
||
intray2 OBJECT IDENTIFIER ::= { intrays 2 }
|
||
intray3 OBJECT IDENTIFIER ::= { intrays 3 }
|
||
imaging OBJECT IDENTIFIER ::= { print-engine 6 }
|
||
print-media OBJECT IDENTIFIER ::= { print-engine 8 }
|
||
settings-print-media OBJECT IDENTIFIER ::= { print-media 1 }
|
||
media-info OBJECT IDENTIFIER ::= { print-media 3 }
|
||
media1 OBJECT IDENTIFIER ::= { media-info 1 }
|
||
media2 OBJECT IDENTIFIER ::= { media-info 2 }
|
||
media3 OBJECT IDENTIFIER ::= { media-info 3 }
|
||
media4 OBJECT IDENTIFIER ::= { media-info 4 }
|
||
media5 OBJECT IDENTIFIER ::= { media-info 5 }
|
||
media6 OBJECT IDENTIFIER ::= { media-info 6 }
|
||
media7 OBJECT IDENTIFIER ::= { media-info 7 }
|
||
media8 OBJECT IDENTIFIER ::= { media-info 8 }
|
||
media9 OBJECT IDENTIFIER ::= { media-info 9 }
|
||
media10 OBJECT IDENTIFIER ::= { media-info 10 }
|
||
media11 OBJECT IDENTIFIER ::= { media-info 11 }
|
||
media12 OBJECT IDENTIFIER ::= { media-info 12 }
|
||
media13 OBJECT IDENTIFIER ::= { media-info 13 }
|
||
media14 OBJECT IDENTIFIER ::= { media-info 14 }
|
||
media15 OBJECT IDENTIFIER ::= { media-info 15 }
|
||
media16 OBJECT IDENTIFIER ::= { media-info 16 }
|
||
media17 OBJECT IDENTIFIER ::= { media-info 17 }
|
||
media18 OBJECT IDENTIFIER ::= { media-info 18 }
|
||
media19 OBJECT IDENTIFIER ::= { media-info 19 }
|
||
media20 OBJECT IDENTIFIER ::= { media-info 20 }
|
||
media21 OBJECT IDENTIFIER ::= { media-info 21 }
|
||
media22 OBJECT IDENTIFIER ::= { media-info 22 }
|
||
media23 OBJECT IDENTIFIER ::= { media-info 23 }
|
||
media24 OBJECT IDENTIFIER ::= { media-info 24 }
|
||
media25 OBJECT IDENTIFIER ::= { media-info 25 }
|
||
media26 OBJECT IDENTIFIER ::= { media-info 26 }
|
||
media27 OBJECT IDENTIFIER ::= { media-info 27 }
|
||
media28 OBJECT IDENTIFIER ::= { media-info 28 }
|
||
media29 OBJECT IDENTIFIER ::= { media-info 29 }
|
||
media30 OBJECT IDENTIFIER ::= { media-info 30 }
|
||
media31 OBJECT IDENTIFIER ::= { media-info 31 }
|
||
media32 OBJECT IDENTIFIER ::= { media-info 32 }
|
||
media33 OBJECT IDENTIFIER ::= { media-info 33 }
|
||
media34 OBJECT IDENTIFIER ::= { media-info 34 }
|
||
media-modes OBJECT IDENTIFIER ::= { print-media 4 }
|
||
consumables OBJECT IDENTIFIER ::= { print-engine 10 }
|
||
consumables-1 OBJECT IDENTIFIER ::= { consumables 1 }
|
||
consumable-status OBJECT IDENTIFIER ::= { consumables-1 1 }
|
||
consumables-status OBJECT IDENTIFIER ::= { consumables 5 }
|
||
consumables-life OBJECT IDENTIFIER ::= { consumables-status 1 }
|
||
consumables-test OBJECT IDENTIFIER ::= { consumables 6 }
|
||
settings-scanner OBJECT IDENTIFIER ::= { scanner 1 }
|
||
scan-calibration OBJECT IDENTIFIER ::= { settings-scanner 32 }
|
||
pe-test-scanner-configuration OBJECT IDENTIFIER ::= { print-engine-test 58 }
|
||
printmib OBJECT IDENTIFIER ::= { dm 2 }
|
||
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
|
||
prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 }
|
||
prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 }
|
||
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
|
||
prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 }
|
||
prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 }
|
||
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
|
||
prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 }
|
||
prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 }
|
||
prtStorageRefTable OBJECT IDENTIFIER ::= { prtGeneral 2 }
|
||
prtStorageRefEntry OBJECT IDENTIFIER ::= { prtStorageRefTable 1 }
|
||
prtDeviceRefTable OBJECT IDENTIFIER ::= { prtGeneral 3 }
|
||
prtDeviceRefEntry OBJECT IDENTIFIER ::= { prtDeviceRefTable 1 }
|
||
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
|
||
prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 }
|
||
prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 }
|
||
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
|
||
prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 }
|
||
prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 }
|
||
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
|
||
prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 }
|
||
prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 }
|
||
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
|
||
prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 }
|
||
prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 }
|
||
prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }
|
||
prtMarkerColorantTable OBJECT IDENTIFIER ::= { prtMarkerColorant 1 }
|
||
prtMarkerColorantEntry OBJECT IDENTIFIER ::= { prtMarkerColorantTable 1 }
|
||
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
|
||
prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 }
|
||
prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 }
|
||
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
|
||
prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 }
|
||
prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 }
|
||
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
|
||
prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 }
|
||
prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 }
|
||
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
|
||
prtConsoleLightTable OBJECT IDENTIFIER ::= { prtConsoleLights 6 }
|
||
prtConsoleLightEntry OBJECT IDENTIFIER ::= { prtConsoleLightTable 1 }
|
||
|
||
|
||
mono-color-switching-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNeverSwitch(1),
|
||
eAlwaysSwitch(2),
|
||
eLookAheadSwitch(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object allows the user to view/change the color/mono
|
||
switching mode for a device.
|
||
Additional information:
|
||
This object allows the user to view/change the color/mono
|
||
switching mode for a device."
|
||
::= { settings-system 31 }
|
||
|
||
|
||
calibration-lowspeed-enable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisable(1),
|
||
eEnable(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Enable or disable an optional low speed calibration. This
|
||
calibration will allow the device to obtain accurate data for
|
||
use with low speed print modes.
|
||
Additional information:
|
||
Enable or disable an optional low speed calibration. This
|
||
calibration will allow the device to obtain accurate data for
|
||
use with low speed print modes."
|
||
::= { settings-system 85 }
|
||
|
||
|
||
marking-agent-density-setting OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the marking agent density setting for each of
|
||
the marking agents installed. The Marking Agent (aka Print)
|
||
density is the instantaneous amount of marking agent applied to
|
||
the media while printing. A value of zero has the lowest print
|
||
density, yielding a lighter page. A value of 10 has the highest
|
||
print density, yielding a darker page. The device POS will
|
||
document what values are supported.
|
||
Additional information:
|
||
See the description for PRINT-DENSITY ."
|
||
::= { marking-agent-density 1 }
|
||
|
||
|
||
marking-agent-highlights-density-setting OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the marking agent highlights density setting
|
||
for each of the marking agents installed. The value of this
|
||
object is in the range of -5..+5. The Marking Agent (aka Print)
|
||
density is the instantaneous amount of marking agent applied to
|
||
the media while printing. A value of -5 has the lowest print
|
||
density, yeilding a lighter pageA value of +5 the highest print
|
||
density, yielding a darker page."
|
||
::= { marking-agent-density 2 }
|
||
|
||
|
||
marking-agent-midtones-density-setting OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the marking agent midtones density setting for
|
||
each of the marking agents installed. The value of this object
|
||
is in the range of -5..+5. See
|
||
MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific
|
||
description."
|
||
::= { marking-agent-density 3 }
|
||
|
||
|
||
marking-agent-shadows-density-setting OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the marking agent shadows density setting for
|
||
each of the marking agents installed. The value of this object
|
||
is in the range of -5..+5. See
|
||
MARKING-AGENT-HIGHLIGHTS-DENSITY-SETTING for a more specific
|
||
description."
|
||
::= { marking-agent-density 4 }
|
||
|
||
|
||
calibration-power-on-initiation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2),
|
||
eDelayed(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object determines when a power on calibration occurs. If
|
||
eOn, then the calibration occurs immediately following boot. If
|
||
eOff, then it never occurs. If eDelayed, then refer to the
|
||
CALIBRATION-POWER-ON-DELAY PML object for the delay interval."
|
||
::= { settings-prt-eng 20 }
|
||
|
||
|
||
calibration-power-on-delay OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This is the delay interval for the power on calibration in
|
||
minutes. This PML object is only used if the
|
||
CALIBRATION-POWER-ON-INITIATION PML object is set to eDelayed.
|
||
Additional information:
|
||
This is the delay interval for the power on
|
||
calibration in minutes. The range in minutes for the product
|
||
is 1-60 minutes. "
|
||
::= { settings-prt-eng 21 }
|
||
|
||
|
||
calibration-pages-printed-initiation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The number of pages that will be printed prior to an
|
||
automatically initiated print calibration. If set to 0, it
|
||
turns this calibration off.
|
||
Additional information:
|
||
This is the number of pages that will be printed
|
||
prior to an automatically initiated print calibration.
|
||
If set to 0, it turns this calibration off. The range for
|
||
the product will be 0-500. On Raptor the default value is
|
||
200. On Kiwi the default value is 150"
|
||
::= { settings-prt-eng 22 }
|
||
|
||
|
||
calibration-timer-initiation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This is a timer in minutes that will be set in between
|
||
calibrations. When the timer expires, a calibration will
|
||
automatically be initiated. If set to 0, it turns this
|
||
calibration off.
|
||
Additional information:
|
||
This is a timer in minutes that will be set in
|
||
between calibrations. If set to 0,
|
||
it turns this calibration off. The range for the product
|
||
will be 0-10080. When you set to a value of 2 (min) or any
|
||
other legal value other than 0, the device does not
|
||
immediately begin calibrating when the timer expires.
|
||
The calibration takes place after the timer expires,
|
||
the next job has finished printing, and a 15 minute period
|
||
of inactivity has passed."
|
||
::= { settings-prt-eng 23 }
|
||
|
||
|
||
calibration-cpr-pages-printed-initiation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The number of pages that will be printed prior to an
|
||
automatically initiated CPR calibration. If set to 0, it turns
|
||
this calibration off.
|
||
Additional information:
|
||
The number of pages that will be printed prior to an
|
||
automatically initiated CPR calibration. If set to 0, it turns
|
||
this calibration off."
|
||
::= { settings-prt-eng 32 }
|
||
|
||
|
||
total-mono-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of black pages printed by the device.
|
||
Additional information:
|
||
Total number of mono pages printed by the device."
|
||
::= { status-prt-eng 6 }
|
||
|
||
|
||
total-color-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of color pages printed by the device.
|
||
Additional information:
|
||
Total number of color pages printed
|
||
by the device."
|
||
::= { status-prt-eng 7 }
|
||
|
||
|
||
marker-density-calibration OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNotCallibrating(1),
|
||
eCalibrateALL(2),
|
||
eCalibrateColor(3),
|
||
eCalibrateColorPlaneRegistration(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns the calibration status or triggers a calibration cycle.
|
||
All calibration procedures are used if set to eCalibrateALL. If
|
||
set to eCalibrateColor then a full density engine calibration
|
||
is triggered. If set to eCalibrateHalftone, then a Halftone
|
||
calibration is triggered. If set to
|
||
eCalibrateColorPlaneRegistration, then a Color Plane
|
||
Registration calibration is triggered. If set to
|
||
eCalibrateDrumPhaseAdjustment, then a Drum Phase Adjustment
|
||
calibration is triggered.If set to eCalibrateLowSpeedColor,
|
||
then a Low Speed Color calibration is triggered.If set to
|
||
eCalibrateDrumSpeedAdjustment, then a Drum Speed Adjustment
|
||
calibration is triggered.If set to eCalibrateNeutrals, then a
|
||
Gray Axis Control calibration is triggered.
|
||
Additional information:
|
||
Returns the calibration status or triggers a
|
||
calibration cycle."
|
||
::= { settings-marking-agent 11 }
|
||
|
||
|
||
pe-test-abort-calibration OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(1),
|
||
eTrue(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Aborts all executing and scheduled calibrations if set to
|
||
eTrue.
|
||
Additional information:
|
||
All scheduled caliberations will abort. Any currently
|
||
executing calibration will finish normally."
|
||
::= { print-engine-test 94 }
|
||
|
||
|
||
copier-token OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..128))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate
|
||
exclusive access to a copier device. Setting the object to a
|
||
unique id will only succeed if the token is currently set to 0.
|
||
The token is unlocked when it is set to 0. If the token is set
|
||
to any value other than 0, then token is locked. If the token
|
||
was set to a unique id (locked), then an attempt to set (lock)
|
||
the token will fail. If the token was set to 0 (unlocked), then
|
||
an attempt to set (lock) the token will succeed in locking the
|
||
token. A get operation on COPIER-TOKEN will return its current
|
||
setting. The device does not prevent access to any objects. It
|
||
is assumed that hosts will be well behaved; respecting this
|
||
advisory locking mechanism by:
|
||
1) acquiring the lock before changing copier objects, and
|
||
|
||
2) releasing the lock when done changing copier objects.
|
||
|
||
Additional information:
|
||
Provides an advisory locking mechanism for hosts to
|
||
coordinate exclusive access. Setting the object to a unique id
|
||
will only succeed if the token is currently set to 0. The token
|
||
is unlocked when it is set to 0. If the token is set to a any
|
||
value other than 0, then token is locked.
|
||
|
||
If the token was set to a unique id (locked), then an
|
||
attempt to set (lock) the token will fail.
|
||
|
||
If the token was set to 0 (unlocked), then an attempt to set (lock)
|
||
the token will succeed in locking the token.
|
||
|
||
A get operation on COPY-TOKEN will return its current setting.
|
||
The device does not prevent access to any objects. It is assumed
|
||
that hosts will be well behaved; respecting this advisory locking
|
||
mechanism by:
|
||
1) acquiring the lock before changing copy objects, and
|
||
2) releasing the lock when done changing copy objects."
|
||
::= { settings-system 24 }
|
||
|
||
|
||
copy-scanner-dimensions OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object is used to obtain the exact pixel scan dimensions
|
||
for copy. The dimensions returned correspond to the quality,
|
||
reduce/enlarge, and media size currently selected.
|
||
Additional information:
|
||
This object is used to obtain the exact pixel scan dimensions for copy.
|
||
The dimensions returned correspond to the quality, reduce/enlarge,
|
||
and media size currently selected."
|
||
::= { status-scanner 13 }
|
||
|
||
|
||
copier-contrast OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Range is 0..100.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command
|
||
which is used for setting the copier contrast level. Contrast
|
||
values can range from -127 to +127, for a total of 255 contrast
|
||
levels. A positive value results in a larger difference, and a
|
||
negative value results in a smaller difference. We support the
|
||
values -125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125.
|
||
We will map by snapping toward 0, to the closest device dependent
|
||
value if some other value is given. "
|
||
::= { settings-copier 2 }
|
||
|
||
|
||
copier-reduction OBJECT-TYPE
|
||
SYNTAX INTEGER(25..400)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Percentage reduction desired for the copier. A value less than
|
||
or equal to zero is invalid. A value greater than 100
|
||
accomplishes magnification. A device is allowed to support a
|
||
set of values (documented in its POS), instead of the full
|
||
range. <OKNearestLegalValue Used> will be returned for unsupported values greater than zero.
|
||
Additional information:
|
||
Percentage reduction desired for the copier. A value less
|
||
than or equal to zero is invalid. A value greater than 100
|
||
accomplishes magnification. A device is allowed to support a set
|
||
of values (documented in its POS), instead of the full range.
|
||
<OKNearestLegalValueUsed> will be returned for unsupported valuesgreater than zero.
|
||
Our default of 100 means no scaling"
|
||
::= { settings-copier 4 }
|
||
|
||
|
||
copier-num-copies OBJECT-TYPE
|
||
SYNTAX INTEGER(1..99)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the number of copies to be printed in the
|
||
next Host requested copy operation.
|
||
Additional information:
|
||
Returns or changes the number of copies to be printed in
|
||
the next Host requested copy operation."
|
||
::= { settings-copier 6 }
|
||
|
||
|
||
copier-collation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eCollateDisabled(1),
|
||
eCollateForward(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Enables the device with local copier capability that also
|
||
supports outputting multiple copies of a multi-paged source
|
||
document to print in a collated fashion.
|
||
eCollateDisabled - The collating feature of the copier
|
||
device is not to be performed on subsequent copier
|
||
operation.
|
||
eCollateForward - Copier device is to print multiple copies
|
||
of the input document in such a way that the printed
|
||
output order matches the source document.
|
||
eCollateReverse - Copier device is to print multiple copies
|
||
of the input document such that the order of the
|
||
printed output is in reverse order of the source
|
||
document.
|
||
Additional information:
|
||
Enables the device with local copier capability that
|
||
also supports outputting multiple copies of a multi-
|
||
paged source document to print in a collated fashion.
|
||
eCollateDisabled - The collating feature of the copier
|
||
device is not to be performed on subsequent copier
|
||
operation.
|
||
eCollateForward - Copier device is to print multiple
|
||
copies of the input document in such a way that the
|
||
printed output order matches the source document."
|
||
::= { settings-copier 7 }
|
||
|
||
|
||
copier-enlargement-maximum OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Maximum value that the host may set COPIER-REDUCTION to. A
|
||
value less than or equal to zero is invalid.
|
||
Additional information:
|
||
Maximum value that the host may set COPIER-REDUCTION or
|
||
COPIER-JOB-REDUCTION to.
|
||
A value less than or equal to zero is invalid."
|
||
::= { settings-copier 11 }
|
||
|
||
|
||
copier-reduction-maximum OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Minimum value that the host may set COPIER-REDUCTION to. A
|
||
value less than or equal to zero is invalid.
|
||
Additional information:
|
||
Minimum value that the host may set COPIER-REDUCTION or
|
||
COPIER-JOB-REDUCTION to.
|
||
A value less than or equal to zero is invalid."
|
||
::= { settings-copier 12 }
|
||
|
||
|
||
copier-quality OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eCopierQualityFast(1),
|
||
eCopierQualityNormal(2),
|
||
eCopierQualityPresentation(3),
|
||
eCopierQualityPicture(6),
|
||
eCopierQualityAutoSelect(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the copier quality. This value is stored in
|
||
NVRAM, hence the value is saved over power cycles.
|
||
Additional information:
|
||
This value is stored in NVRAM, hence the value is
|
||
saved over power cycles.
|
||
|
||
eCopierQualityFast is mapped to eCopierQualityNormal."
|
||
::= { settings-copier 13 }
|
||
|
||
|
||
copier-adf-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages scanned for
|
||
copying through the ADF. In order to write this object
|
||
SERVICE-PASSWORD must be set correctly.
|
||
Additional information:
|
||
This object tracks the page count for pages
|
||
scanned for copying through the ADF. This value is
|
||
stored in the device NVRAM."
|
||
::= { settings-copier 19 }
|
||
|
||
|
||
copier-print-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages sent to the
|
||
print engine, for copy jobs. In order to write this object
|
||
SERVICE-PASSWORD must be set correctly.
|
||
Additional information:
|
||
This object tracks the page count for pages sent to
|
||
the print engine, for monochrome copy jobs. This value is
|
||
stored in the device NVRAM."
|
||
::= { settings-copier 20 }
|
||
|
||
|
||
copier-job-media-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eISOandJISA4(26)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The user can set a copy job setting for paper size using the
|
||
COPIER-JOB-MEDIA-SIZE object, which is independent of other
|
||
functions in the device. The device behavior when the scanned
|
||
media and or print media do not match the value of this object
|
||
should be documented in the device POS. (for a full list of
|
||
media size enums see the end of this file)
|
||
Additional information:
|
||
The default size for imaging a copy is
|
||
determined by reading the common device default paper size
|
||
object. The default for copy size cannot be changed
|
||
independently of other functions like fax and print. The
|
||
device will scan and format the print data based on the value
|
||
of this object."
|
||
::= { settings-copier 21 }
|
||
|
||
|
||
copier-job-quality OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eCopierQualityFast(1),
|
||
eCopierQualityNormal(2),
|
||
eCopierQualityPresentation(3),
|
||
eCopierQualityDraft(6),
|
||
eCopierQualityAutoSelect(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the copier quality.
|
||
Additional information:
|
||
Returns or sets the copier quality.
|
||
eCopierQualityFast is supported but gets mapped to normal."
|
||
::= { settings-copier 22 }
|
||
|
||
|
||
copier-job-collation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eCollateDisabled(1),
|
||
eCollateForward(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Enables the device with local copier capability that also
|
||
supports outputting multiple copies of a multi-paged source
|
||
document to print in a collated fashion. eCollateDisabled - The
|
||
collating feature of the copier device is not be performed on
|
||
subsequent copier operation. eCollateForward - Copier device is
|
||
to print multiple copies of the input document in such a way
|
||
that the printed output order matches the source document.
|
||
eCollateReverse - Copier device is to print multiple copies of
|
||
the input document such that the order of the printed output is
|
||
in reverse order of the source document. "
|
||
::= { settings-copier 23 }
|
||
|
||
|
||
copier-job-num-copies OBJECT-TYPE
|
||
SYNTAX INTEGER(1..99)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the number of copies to be printed in the
|
||
next Host requested copy operation."
|
||
::= { settings-copier 24 }
|
||
|
||
|
||
copier-job-reduction OBJECT-TYPE
|
||
SYNTAX INTEGER(25..400)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Percentage reduction desired for the copier. A device is
|
||
allowed to support a set of values (documented in its POS),
|
||
instead of the full range. <OKNearesetLegalValueUsed> will be
|
||
returned for unsupported values.
|
||
Additional information:
|
||
A value less than or equal to zero is invalid.
|
||
A value greater than 100 accomplishes magnification.
|
||
<OKNearestLegalValueUsed> will be returned for unsupported valuesgreater than zero.
|
||
(default = 100 = no scaling)."
|
||
::= { settings-copier 25 }
|
||
|
||
|
||
copier-job-contrast OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Used to set the copier contrast level.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command
|
||
which is used for setting the copier contrast level. Contrast values
|
||
can range from <20>-127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value results
|
||
in a larger difference, and a negative value results in a smaller
|
||
difference.
|
||
We support values of -125, -100, -75, -50, -25, 0, 25, 50, 75,
|
||
100, 125. The range of values we support is spread over a
|
||
range such that a software product would support the standard spec,
|
||
and we would map by snapping toward 0 to the closest device dependent
|
||
value."
|
||
::= { settings-copier 26 }
|
||
|
||
|
||
copier-job OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eCopierIdle(1),
|
||
eCopierStart(2),
|
||
eCopierActive(3),
|
||
eCopierAborting(4),
|
||
eCopierSetup(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Controls initiating and canceling a copy job.
|
||
Additional information:
|
||
Controls initiating and canceling a copy job.
|
||
eCopierIdle <20> indicates that a copy function is not in progress.
|
||
- Device sets to this state from eCopierActive to signal successful
|
||
completion of copy operation.
|
||
- Device sets to this state from eCopierAborting to signal successful
|
||
cancel of copy operation.
|
||
- Device sets to this state from eCopierStart to signal that the device is
|
||
busy and cannot perform a copy operation.
|
||
- Host sets to this state to indicate it wants to cancel the job. Device
|
||
will abort the job.
|
||
|
||
eCopierSetup <20> indicates the host wants to set up job settings for a copy
|
||
job. Host sets to this state to then access copier job settings objects.
|
||
Device does not set to this state. Object can only transition to this state
|
||
from eCopierIdle.
|
||
|
||
eCopierStart - This state is set by host to request copy function initiation.
|
||
Object can only transition to this state from eCopierSetup.
|
||
To specify job settings host has to set to Setup first,
|
||
send settings, then set to Start. Device should not set to this state.
|
||
|
||
eCopierActive <20> indicates the copy function is in progress. Device sets this
|
||
state if the activity was started through front panel or if host request was
|
||
successfully initiated. Host should not set to this state.
|
||
|
||
eCopierAborting <20> Set by device to indicate copy function was prematurely
|
||
terminated, either by an error, or user canceled by pressing cancel button
|
||
on device. Device stays in this state until abort is complete, then moves to
|
||
eCopierIdle. Host cannot set to this state, host sets to eCopierIdle to indicate
|
||
it want to cancel the job.
|
||
|
||
- Device powers up in eCopierIdle. "
|
||
::= { settings-copier 27 }
|
||
|
||
|
||
default-copy-duplex-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eSimplexToSimplex(1),
|
||
eSimplexToDuplexLongEdgeBinding(2),
|
||
eDuplexToDuplex(4),
|
||
eDuplexToSimplexLongEdgeBinding(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the duplex copying mode. Duplex printing is
|
||
when printing occurs on both sides of a sheet of media. Long
|
||
edge binding is also called vertical binding or book binding.
|
||
Short edge binding is also called horizontal binding or
|
||
calendar binding.
|
||
eSimplexToSimplex: takes image data from only one side of
|
||
the original document, and print only on one side of
|
||
each copy.
|
||
eSimplexToDuplexLongEdgeBinding: takes image data from only
|
||
one side of the original document, and print to both
|
||
sides of each copy. The images are rotated so that if
|
||
the media is rotated along the axis of the long edge of
|
||
the media, both images would appear as in the original.
|
||
|
||
eSimplexToDuplexShortEdgeBinding: takes image data from
|
||
only one side of the original document, and print to
|
||
both sides of each copy. The images are rotated so that
|
||
if the media is rotated along the axis of the short
|
||
edge of the media, both images would appear as in the
|
||
original.
|
||
eDuplexToDuplex: takes image data from both sides of the
|
||
original document, and print on both sides of each
|
||
copy.
|
||
eDuplexToSimplexLongEdgeBinding: takes image data from both
|
||
sides of the original document, and prints to only one
|
||
side of each copy. The images are rotated so that if
|
||
the media is rotated along the axis of the long edge of
|
||
the media, both images would appear as in the original.
|
||
|
||
eDuplexToSimplexShortEdgeBinding: takes image data from
|
||
both sides of the original document, and prints to only
|
||
one side of each copy. The images are rotated so that
|
||
if the media is rotated along the axis of the short
|
||
edge of the media, both images would appear as in the
|
||
original.
|
||
Additional information:
|
||
Returns or sets the duplex copying mode. Duplex printing is
|
||
when printing occurs on both sides of a sheet of media. Long
|
||
edge binding is also called vertical binding or book binding.
|
||
Short edge binding is also called horizontal binding or
|
||
calendar binding.
|
||
eSimplexToSimplex: takes image data from only one side of
|
||
the original document, and print only on one side of
|
||
each copy.
|
||
eSimplexToDuplexLongEdgeBinding: takes image data from only
|
||
one side of the original document, and print to both
|
||
sides of each copy. The images are rotated so that if
|
||
the media is rotated along the axis of the long edge of
|
||
the media, both images would appear as in the original.
|
||
|
||
eSimplexToDuplexShortEdgeBinding: takes image data from
|
||
only one side of the original document, and print to
|
||
both sides of each copy. The images are rotated so that
|
||
if the media is rotated along the axis of the short
|
||
edge of the media, both images would appear as in the
|
||
original.
|
||
eDuplexToDuplex: takes image data from both sides of the
|
||
original document, and print on both sides of each
|
||
copy.
|
||
eDuplexToSimplexLongEdgeBinding: takes image data from both
|
||
sides of the original document, and prints to only one
|
||
side of each copy. The images are rotated so that if
|
||
the media is rotated along the axis of the long edge of
|
||
the media, both images would appear as in the original.
|
||
|
||
eDuplexToSimplexShortEdgeBinding: takes image data from
|
||
both sides of the original document, and prints to only
|
||
one side of each copy. The images are rotated so that
|
||
if the media is rotated along the axis of the short
|
||
edge of the media, both images would appear as in the
|
||
original.
|
||
If duplex print has been disabled the object will return an error
|
||
for pmlsets on eSimplexToDuplexLongEdgeBinding(2) and
|
||
eDuplexToDuplex(4). If duplex scan has been disabled it will
|
||
return an error for pmlsets on eDuplexToDuplex(4) and
|
||
eDuplexToSimplexLongEdgeBinding(5).If the device has both disabled
|
||
or the features is are present, such as on a kiwi, both pmlsets and
|
||
pmlgets will return an error for all enumerations."
|
||
::= { settings-copier 28 }
|
||
|
||
|
||
copier-flatbed-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages scanned for
|
||
copying from the flatbed. In order to write this object
|
||
SERVICE-PASSWORD must be set correctly.
|
||
Additional information:
|
||
This object tracks the page count for pages
|
||
scanned for copying from the flatbed. This value is
|
||
stored in the device NVRAM."
|
||
::= { settings-copier 44 }
|
||
|
||
|
||
copier-pages-per-sheet OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePagesPerSheet1(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the copier number of input pages per output
|
||
sheet. This is also known as nup. This value is stored in
|
||
NVRAM, hence the value is saved over power cycles.
|
||
Additional information:
|
||
Enables the device with local copier capability that
|
||
also supports outputting multiple copies of a multi-
|
||
paged source document to print multiple input sheets onto
|
||
a single output sheet.
|
||
ePagesPerSheet_1: A single input image is placed on a
|
||
single output sheet. This basically has no affect.
|
||
ePagesPerSheet_2: Two input images are placed on a
|
||
single output sheet, in landscape format.
|
||
ePagesPerSheet_4: Four input images are placed on
|
||
a single output sheet, in portrait format.
|
||
NOTE: The Pages Per Sheet feature will only be supported
|
||
on devices with an ADF. If no ADF is present, then
|
||
changes to this object will not be allowed."
|
||
::= { settings-copier 45 }
|
||
|
||
|
||
copier-job-pages-per-sheet OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePagesPerSheet1(1),
|
||
ePagesPerSheet2(2),
|
||
ePagesPerSheet4(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the copy value for how many input pages per
|
||
output sheet.
|
||
Additional information:
|
||
Enables the device with local copier capability that
|
||
also supports outputting multiple copies of a multi-
|
||
paged source document to print multiple input sheets onto
|
||
a single output sheet.
|
||
ePagesPerSheet1: A single input image is placed on a
|
||
single output sheet. This basically has no affect.
|
||
ePagesPerSheet2: Two input images are placed on a
|
||
single output sheet, in landscape format.
|
||
ePagesPerSheet4: Four input images are placed on
|
||
a single output sheet, in portrait format.
|
||
NOTE: The Pages Per Sheet feature will only be supported
|
||
on devices with an ADF. If no ADF is present, then
|
||
changes to this object will not be allowed."
|
||
::= { settings-copier 46 }
|
||
|
||
|
||
copier-fit-to-page OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFitToPageDisabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the copy setting for fit to page. This value is
|
||
stored in NVRAM; hence, the value is saved over power cycles.
|
||
Additional information:
|
||
Enables the device with local copier capability to
|
||
fit the input image size automatically onto the output sheet
|
||
size."
|
||
::= { settings-copier 47 }
|
||
|
||
|
||
copier-job-fit-to-page OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFitToPageDisabled(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the copy value for fit to page.
|
||
Additional information:
|
||
Enables the device with local copier capability to
|
||
fit the input image size automatically onto the output sheet
|
||
size."
|
||
::= { settings-copier 48 }
|
||
|
||
|
||
copier-pages-per-sheet-maximum OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Maximum pages per sheet value supported by the COPIER-
|
||
PAGES-PER-SHEET and COPIER-JOB-PAGES-PER-SHEET objects. A value
|
||
less than or equal to zero is invalid.
|
||
Additional information:
|
||
Maximum value supported for COPIER-PAGES-PER-SHEET or
|
||
COPIER-JOB-PAGES-PER-SHEET objects.
|
||
A value less than or equal to zero is invalid."
|
||
::= { settings-copier 49 }
|
||
|
||
|
||
copier-print-color-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for pages sent to the print
|
||
engine for color copy jobs. This value is stored in the device
|
||
NVRAM.
|
||
Additional information:
|
||
This object tracks the page count for pages sent to
|
||
the print engine, for color copy jobs. This value is stored
|
||
in the device NVRAM."
|
||
::= { settings-copier 64 }
|
||
|
||
|
||
copier-adf-test-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This is only writable in service mode. When this object is
|
||
enabled, all copy jobs following will only scan the pages and
|
||
throw the data away rather than printing. This is used for
|
||
testing the ADF. When this is disabled, the device will copy as
|
||
normal.
|
||
Additional information:
|
||
This is only writable in service mode. When this
|
||
object is set to enabled, all copy jobs following will only
|
||
scan the pages and throw the data away rather than printing.
|
||
This is used for testing the ADF. When this is set back to
|
||
disabled, then the device will copy as normal."
|
||
::= { settings-copier 65 }
|
||
|
||
|
||
copier-adf-test-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Reads the number of pages printed during the last ADF copy
|
||
test. This object is associated with the COPIER-ADF-TEST-MODE
|
||
object.
|
||
Additional information:
|
||
Reads the number of pages printed during the last
|
||
ADF copy test. This is associated with the COPIER-ADF-TEST-MODE
|
||
object."
|
||
::= { settings-copier 66 }
|
||
|
||
|
||
copier-job-advanced-contrast OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value."
|
||
::= { settings-copier 70 }
|
||
|
||
|
||
copier-advanced-contrast OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given. "
|
||
::= { settings-copier 71 }
|
||
|
||
|
||
copier-job-sharpen OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75,100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75,100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value."
|
||
::= { settings-copier 72 }
|
||
|
||
|
||
copier-sharpen OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given. "
|
||
::= { settings-copier 73 }
|
||
|
||
|
||
copier-job-background-removal OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value."
|
||
::= { settings-copier 74 }
|
||
|
||
|
||
copier-background-removal OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given. "
|
||
::= { settings-copier 75 }
|
||
|
||
|
||
copier-job-lightness OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value."
|
||
::= { settings-copier 76 }
|
||
|
||
|
||
copier-lightness OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given. "
|
||
::= { settings-copier 77 }
|
||
|
||
|
||
copier-job-grayness OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value."
|
||
::= { settings-copier 78 }
|
||
|
||
|
||
copier-grayness OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given. "
|
||
::= { settings-copier 79 }
|
||
|
||
|
||
copier-job-red-color-balance OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value."
|
||
::= { settings-copier 80 }
|
||
|
||
|
||
copier-red-color-balance OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given. "
|
||
::= { settings-copier 81 }
|
||
|
||
|
||
copier-job-blue-color-balance OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value."
|
||
::= { settings-copier 82 }
|
||
|
||
|
||
copier-blue-color-balance OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given. "
|
||
::= { settings-copier 83 }
|
||
|
||
|
||
copier-job-green-color-balance OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels.
|
||
The default contrast level is 0 (normal). A positive value
|
||
results in a larger difference, and a negative value results in
|
||
a smaller difference. We support values of -125, -100, -75,
|
||
-50, -25, 0, 25, 50, 75, 100, 125. The range of values we
|
||
support is spread over a range such that a software product
|
||
would support the standard spec, and we would map by snapping
|
||
toward 0 to the closest device dependent value."
|
||
::= { settings-copier 84 }
|
||
|
||
|
||
copier-green-color-balance OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given.
|
||
Additional information:
|
||
Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the copier contrast level. Contrast values can
|
||
range from -127 to +127, for a total of 255 contrast levels. A
|
||
positive value results in a larger difference, and a negative
|
||
value results in a smaller difference. We support the values
|
||
-125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125. We will map
|
||
by snapping toward 0, to the closest device dependent value if
|
||
some other value is given. "
|
||
::= { settings-copier 85 }
|
||
|
||
|
||
copier-job-draft-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOn(1),
|
||
eOff(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Enables the device with local copier capability to turn on a
|
||
draft printing mode.
|
||
Additional information:
|
||
Enables the device with local copier capability to turn on a
|
||
draft printing mode."
|
||
::= { settings-copier 86 }
|
||
|
||
|
||
copier-draft-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOn(1),
|
||
eOff(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Enables the device with local copier capability to turn on a
|
||
draft printing mode.
|
||
Additional information:
|
||
Enables the device with local copier capability to turn on a
|
||
draft printing mode."
|
||
::= { settings-copier 87 }
|
||
|
||
|
||
copier-job-multipage OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOn(1),
|
||
eOff(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Enables the device with local copier capability to turn on
|
||
multi page copying from the flatbed.
|
||
Additional information:
|
||
Enables the device with local copier capability to turn on
|
||
multi page copying from the flatbed."
|
||
::= { settings-copier 88 }
|
||
|
||
|
||
copier-multipage OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOn(1),
|
||
eOff(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Enables the device with local copier capability to turn on
|
||
multi page copying from the flatbed.
|
||
Additional information:
|
||
Enables the device with local copier capability to turn on
|
||
multi page copying from the flatbed."
|
||
::= { settings-copier 89 }
|
||
|
||
|
||
device-cfg-download OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eCfgDownloadIdle(1),
|
||
eCfgDownloadStart(2),
|
||
eCfgDownloadActive(3),
|
||
eCfgDownloadAborted(4),
|
||
eCfgDownloadDone(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Handshaking mechanism between host and device to coordinate the
|
||
download of device specific data.
|
||
eCfgDownloadIdle - indicates device configuration download
|
||
activity is not occurring. Device powers up in this
|
||
state but will otherwise never transition to this
|
||
state. This state is host settable from
|
||
eCfgDownloadActive, eCfgDownloadDone, and
|
||
eCfgDownloadAborted. Host setting to eCfgDownloadIdle
|
||
while object is in eCfgDownloadActive will cause the
|
||
download activity to be prematurely terminated. Host
|
||
setting to this state resets the object to permit
|
||
another download activity to be initiated.
|
||
eCfgDownloadStart - indicates host wishes to commence a
|
||
device configuration download activity. This state is
|
||
only host settable from eCfgDownloadIdle. Only the
|
||
device can transition this object from this state to
|
||
eCfgDownloadActive or eCfgDownloadAborted. Device will
|
||
not set to this state.
|
||
eCfgDownloadActive - indicates download activity is in
|
||
progress. Device transitions object to this state only
|
||
from eCfgDownloadStart, to signal data download can
|
||
commence. The device can transition from this state to
|
||
eCfgDownloadDone or eCfgDownloadAborted. The host can
|
||
transition from this state to eCfgDownloadIdle. This
|
||
state is not host settable.
|
||
eCfgDownloadAborted - indicates the download activity was
|
||
terminated by the device. Only the device can set to
|
||
this state from eCfgDownloadStart or
|
||
eCfgDownloadActive. Only the host can transition from
|
||
this state to eCfgDownloadIdle. This state is not host
|
||
settable.
|
||
eCfgDownloadDone - indicates device has completely received
|
||
the download data. Device transitions to this state
|
||
only from eCfgDownloadActive. Only the host can
|
||
transition from this state to eCfgDownloadIdle. This
|
||
state is not host settable. "
|
||
::= { settings-system 11 }
|
||
|
||
|
||
device-cfg-download-data-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eSpeedDials(5),
|
||
eFaxLogs(6),
|
||
eConfigPrams(7),
|
||
eJunkFaxDialStrings(9)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the type of device specific data to be downloaded."
|
||
::= { settings-system 12 }
|
||
|
||
|
||
device-cfg-upload OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eCfgUploadIdle(1),
|
||
eCfgUploadStart(2),
|
||
eCfgUploadActive(3),
|
||
eCfgUploadAborted(4),
|
||
eCfgUploadDone(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Handshaking mechanism between host and device to coordinate the
|
||
upload of device specific data.
|
||
eCfgUploadIdle - indicates device configuration upload
|
||
activity is not occurring. Device powers up in this
|
||
state but will otherwise never transition to this
|
||
state. This state is host settable from
|
||
eCfgUploadActive, eCfgUploadDone, and
|
||
eCfgUploadAborted. Host setting to eCfgUploadIdle while
|
||
object is in eCfgUploadActive will cause the upload
|
||
activity to be prematurely terminated. Host setting to
|
||
this state resets the object allowing a new upload to
|
||
be initiated.
|
||
eCfgUploadStart - indicates host wishes to commence a
|
||
device configuration upload activity. This state is
|
||
only host settable from eCfgUploadIdle. Only the device
|
||
can transition this object from this state to
|
||
eCfgUploadActive or eCfgUploadAborted. Device will not
|
||
set to this state.
|
||
eCfgUploadActive - indicates upload activity is in
|
||
progress. Device transitions object to this state only
|
||
from eCfgUploadStart, to signal data upload can
|
||
commence. The device can transition from this state to
|
||
eCfgUploadDone or eCfgUploadAborted. The host can
|
||
transition from this state to eCfgUploadIdle. This
|
||
state is not host settable.
|
||
eCfgUploadAborted - indicates the upload activity was
|
||
terminated by the device. Only the device can set to
|
||
this state from eCfgUploadStart or eCfgUploadActive.
|
||
Only the host can transition from this state to
|
||
eCfgUploadIdle. This state is not host settable.
|
||
eCfgUploadDone - indicates device completely transmitted
|
||
the upload data. Device transitions to this state only
|
||
from eCfgUploadActive. Only the host can transition
|
||
from this state to eCfgUploadIdle. This state is not
|
||
host settable. "
|
||
::= { settings-system 13 }
|
||
|
||
|
||
device-cfg-upload-data-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eSpeedDials(5),
|
||
eFaxLogs(6),
|
||
eConfigPrams(7),
|
||
eJunkFaxDialStrings(9)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the type of device specific data to be uploaded."
|
||
::= { settings-system 14 }
|
||
|
||
|
||
download-timeout OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Specifies the number of seconds that device will wait for data
|
||
from the host before the device determines the host is being
|
||
unresponsive. This timeout condition may cause the device to
|
||
take recourse action regarding the disposition of the download
|
||
activity. A value of zero indicates device will wait forever
|
||
for the host data. POS should indicate whether this object
|
||
value, when set by the host, is remembered between device power
|
||
cycles.
|
||
Additional information:
|
||
This object is volatile and as such will not be
|
||
retained by the device between power cycles."
|
||
::= { settings-system 17 }
|
||
|
||
|
||
upload-timeout OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Specifies the number of seconds that device will wait for
|
||
response from the host after transmitting a unit of data before
|
||
the device determines the host is being unresponsive. This
|
||
timeout condition may cause the device to take recourse action
|
||
regarding the disposition of the upload activity. A value of
|
||
zero indicates device will wait forever for the host response.
|
||
POS should indicate whether this object value, when set by the
|
||
host, is remembered between device power cycles.
|
||
Additional information:
|
||
This object is volatile and as such will not be
|
||
retained by the device between power cycles."
|
||
::= { settings-system 18 }
|
||
|
||
|
||
date-display OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDateDisplayMMDDYY(1),
|
||
eDateDisplayDDMMYY(2),
|
||
eDateDisplayYYMMDD(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Controls front-panel date display format.
|
||
Additional information:
|
||
Controls front-panel date display format."
|
||
::= { settings-system 22 }
|
||
|
||
|
||
device-cfg-param-command OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "A C structure containing the following fields: typedef
|
||
struct {
|
||
u8bit list_id;
|
||
s8bit auto_incr;
|
||
u16bit max_index;
|
||
u16bit rec_size;
|
||
u16bit index;
|
||
u8bit data[];
|
||
} PML_device_cfg_param_cmd_t;
|
||
where u8bit is an unsigned byte (0..255), s8bit is a signed
|
||
byte (-128..127), and u16bit is a big endian format unsigned
|
||
short (0..65535). The POS should state which list_id's the
|
||
device supports.
|
||
Additional information:
|
||
This LaserJet MFP supports two values for list_id:
|
||
0 for configuration parameters and
|
||
1 for default configuration parameters."
|
||
::= { settings-system 23 }
|
||
|
||
|
||
fax-upload-token OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..128))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate
|
||
exclusive access to the fax upload features of a device.
|
||
Setting the object to a unique id will only succeed if the
|
||
token is currently set to 0. The token is unlocked when it is
|
||
set to 0. If the token is set to any value other than 0, then
|
||
token is locked. If the token was set to a unique id (locked),
|
||
then an attempt to set (lock) the token will fail. If the token
|
||
was set to 0 (unlocked), then an attempt to set (lock) the
|
||
token will succeed in locking the token. A get operation on
|
||
FAX-UPLOAD-TOKEN will return its current setting. The device
|
||
does not prevent access to any objects. It is assumed that
|
||
hosts will be well behaved; respecting this advisory locking
|
||
mechanism by:
|
||
1) acquiring the lock before changing any fax-upload
|
||
objects, and
|
||
2) releasing the lock when done changing scan objects.
|
||
Additional information:
|
||
Provides an advisory locking mechanism for hosts to
|
||
coordinate exclusive access. Setting the object to a unique id
|
||
will only succeed if the token is currently set to 0. The token
|
||
is unlocked when it is set to 0. If the token is set to a any
|
||
value other than 0, then token is locked.
|
||
|
||
If the token was set to a unique id (locked), then an
|
||
attempt to set (lock) the token will fail.
|
||
|
||
If the token was set to 0 (unlocked), then an attempt to set (lock)
|
||
the token will succeed in locking the token.
|
||
|
||
A get operation on FAX-UPLOAD-TOKEN will return its current setting.
|
||
The device does not prevent access to any objects. It is assumed
|
||
that hosts will be well behaved; respecting this advisory locking
|
||
mechanism by:
|
||
1) acquiring the lock before changing fax objects, and
|
||
2) releasing the lock when done changing fax objects."
|
||
::= { settings-system 26 }
|
||
|
||
|
||
fax-download-token OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..128))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate
|
||
exclusive access to the fax download features of a device.
|
||
Setting the object to a unique id will only succeed if the
|
||
token is currently set to 0. The token is unlocked when it is
|
||
set to 0. If the token is set to any value other than 0, then
|
||
token is locked. If the token was set to a unique id (locked),
|
||
then an attempt to set (lock) the token will fail. If the token
|
||
was set to 0 (unlocked), then an attempt to set (lock) the
|
||
token will succeed in locking the token. A get operation on
|
||
FAX-DOWNLOAD-TOKEN will return its current setting. The device
|
||
does not prevent access to any objects. It is assumed that
|
||
hosts will be well behaved; respecting this advisory locking
|
||
mechanism by:
|
||
1) acquiring the lock before changing any fax-download
|
||
objects, and
|
||
2) releasing the lock when done changing scan objects.
|
||
Additional information:
|
||
Provides an advisory locking mechanism for hosts to
|
||
coordinate exclusive access. Setting the object to a unique id
|
||
will only succeed if the token is currently set to 0. The token
|
||
is unlocked when it is set to 0. If the token is set to a any
|
||
value other than 0, then token is locked.
|
||
|
||
If the token was set to a unique id (locked), then an
|
||
attempt to set (lock) the token will fail.
|
||
|
||
If the token was set to 0 (unlocked), then an attempt to set (lock)
|
||
the token will succeed in locking the token.
|
||
|
||
A get operation on FAX-DOWNLOAD-TOKEN will return its current setting.
|
||
The device does not prevent access to any objects. It is assumed
|
||
that hosts will be well behaved; respecting this advisory locking
|
||
mechanism by:
|
||
1) acquiring the lock before changing fax objects, and
|
||
2) releasing the lock when done changing fax objects."
|
||
::= { settings-system 27 }
|
||
|
||
|
||
date-and-time OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "A C structure containing the following fields: typedef
|
||
struct {
|
||
ubyte yr; /* year: 0 to 99 */
|
||
ubyte mon; /* month: 1 to 12 */
|
||
ubyte day; /* day: 1 to 31 */
|
||
ubyte wday; /* Day of week: 1 to 07 */
|
||
ubyte hr; /* hour: 0 to 23 */
|
||
ubyte min; /* minute: 0 to 59 */
|
||
ubyte sec; /* second: 0 to 59 */
|
||
} date_t;
|
||
where ubyte is an unsigned byte (0-255)."
|
||
::= { status-system 17 }
|
||
|
||
|
||
time-display OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTimeDisplayTwelveHour(1),
|
||
eTimeDisplayTwentyFourHour(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Controls front-panel time display format. Set to
|
||
eTimeDisplayTwelveHour for AM/PM display. Set to
|
||
eTimeDisplayTwentyFourHour for military-type display."
|
||
::= { status-system 28 }
|
||
|
||
|
||
device-cfg-download-error OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Error status of the configuration download session. POS should
|
||
indicate the actual error values reserving value 0 as NO
|
||
ERROR.
|
||
Additional information:
|
||
A value of 0 indicates NO ERROR."
|
||
::= { status-system 43 }
|
||
|
||
|
||
device-cfg-upload-error OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Error status of the configuration upload session. POS should
|
||
indicate the actual error values reserving value 0 as NO
|
||
ERROR.
|
||
Additional information:
|
||
A value of 0 indicates NO ERROR."
|
||
::= { status-system 45 }
|
||
|
||
|
||
fax-local-phone-num OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "CCITT sender's station id (ex. 08-396-4122)."
|
||
::= { id 8 }
|
||
|
||
|
||
fax-station-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "name for the fax device (ex. HP R&D)."
|
||
::= { id 9 }
|
||
|
||
|
||
fax-line-interface-unit-id OBJECT-TYPE
|
||
SYNTAX INTEGER(0..8)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The fax device line interface unit (LIU) identifier. The LIU
|
||
number identifies the telephone system electrical
|
||
characteristics supported by this device.
|
||
Additional information:
|
||
In this LaserJet MFP this value is stored in 3 bits on the
|
||
LIU."
|
||
::= { id 18 }
|
||
|
||
|
||
cancel-job OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Cancels the print job whose ID matches the value written to the
|
||
CANCEL-JOB object. The host first learns the job ID using the
|
||
CURRENT-JOB-PARSING-ID command. If the printer has completely
|
||
processed the job, the printer responds with
|
||
<badValue>. If the value of the
|
||
CURRENT-JOB-PARSING-ID is smaller than the value written to the
|
||
CANCEL-JOB object, then the printer responds with
|
||
<badValue>. When read, returns the value
|
||
of the last job ID what was canceled, or -1 to indicate no job
|
||
has been canceled."
|
||
::= { settings-job 2 }
|
||
|
||
|
||
faxjob-action OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePrintFaxToPrinter(1),
|
||
eDeleteFaxFromMemory(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Permits host to specify an action to be applied with a
|
||
particular fax."
|
||
::= { settings-fax-job 1 }
|
||
|
||
|
||
faxjob-action-id OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Contains the fax job identification of the fax to be acted upon
|
||
by the action specified by the object FAXJOB-ACTION."
|
||
::= { settings-fax-job 2 }
|
||
|
||
|
||
faxjob-tx-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eSrcHostOnly(2),
|
||
eSrcScannerOnly(5),
|
||
eSrcHostToMemoryOnly(9)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates sources of the fax image for transmission. Also
|
||
specifies the temporal order of the data sources.
|
||
eSrcHostOnly - The fax document images will be wholly
|
||
downloaded from the host.
|
||
eSrcScannerOnly - The fax document images originate wholly
|
||
from the device scanner/ADF subsystem.
|
||
eSrcHostThenScanner - The fax document is composed of
|
||
images downloaded from the host and pages from the
|
||
scanner/ADF subsystem. The host downloaded pages will
|
||
be faxed first, followed by the pages in the
|
||
scanner/ADF.
|
||
eSrcScannerThenHost - The fax document is composed of pages
|
||
in the scanner/ADF and the images downloaded from the
|
||
host. The document in the ADF is faxed first, followed
|
||
by the pages downloaded from the host.
|
||
eSrcHostThenMemory - The fax document is composed of pages
|
||
downloaded from the host and images already stored
|
||
within the device. The fax transmission will contain
|
||
the host downloaded pages followed by the images in the
|
||
device memory.
|
||
eSrcHostToMemoryOnly - Permits fax images to be downloaded
|
||
into device memory for later use with
|
||
eSrcHostThenMemory.
|
||
Additional information:
|
||
eSrcHostToMemoryOnly is included for
|
||
development and testing only. eSrcHostToMemoryOnly will
|
||
not be an allowed value for this object in the released
|
||
product."
|
||
::= { settings-fax-job 3 }
|
||
|
||
|
||
faxjob-print-duplex-mode-select OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDuplexerDisabled(1),
|
||
eDuplexerEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Allows the host to enable or disable duplex printing on a
|
||
device for the next fax job.
|
||
Additional information:
|
||
Allows the host to enable or disable duplex printing on a
|
||
device for the next fax job."
|
||
::= { settings-fax-job 5 }
|
||
|
||
|
||
faxjob-download-id OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains the device assigned job identification for the current
|
||
fax downloading job. The job ID is monotonically increasing
|
||
number. The job ID may be reset to zero or may roll over to
|
||
zero after reaching some maximum. The maximum value before the
|
||
rollover should be stated in the POS.
|
||
Additional information:
|
||
The maximum value before this object rolls over
|
||
to 0 is 2,147,483,648. Behavior of this object once
|
||
the value rolls over to 0 is not specified."
|
||
::= { status-fax-job 1 }
|
||
|
||
|
||
faxjob-rx-id OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains the device assigned job identification for the
|
||
currently fax reception job. The job ID is monotonically
|
||
increasing number. The job ID may be reset to zero or may roll
|
||
over to zero after reaching some maximum. The maximum value
|
||
before the rollover should be stated in the POS.
|
||
Additional information:
|
||
The maximum value before this object rolls over
|
||
to 0 is 2,147,483,648. Behavior of this object once
|
||
the value rolls over to 0 is not specified."
|
||
::= { status-fax-job 2 }
|
||
|
||
|
||
faxjob-tx-id OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains the device assigned job identification for the current
|
||
fax transmission job. The job ID is monotonically increasing
|
||
number. The job ID may be reset to zero or may roll over to
|
||
zero after reaching some maximum. The maximum value before the
|
||
rollover should be stated in the POS.
|
||
Additional information:
|
||
The maximum value before this object rolls over
|
||
to 0 is 2,147,483,648. Behavior of this object once
|
||
the value rolls over to 0 is not specified."
|
||
::= { status-fax-job 3 }
|
||
|
||
|
||
faxjob-upload-id OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains the device assigned job identification for the current
|
||
fax upload job. The job ID is monotonically increasing number.
|
||
The job ID may be reset to zero or may roll over to zero after
|
||
reaching some maximum. The maximum value before the rollover
|
||
should be stated in the POS.
|
||
Additional information:
|
||
The maximum value before this object rolls over
|
||
to 0 is 2,147,483,648. Behavior of this object once
|
||
the value rolls over to 0 is not specified."
|
||
::= { status-fax-job 4 }
|
||
|
||
|
||
faxjob-rx-status-1 OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFaxRxIdle(1),
|
||
eFaxRxRinging(2),
|
||
eFaxRxAnswering(3),
|
||
eFaxRxReceiving(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Status of receiving fax session 1."
|
||
::= { faxjob-rx-status 1 }
|
||
|
||
|
||
faxjob-tx-status-1 OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFaxTxIdle(1),
|
||
eFaxTxDialing(2),
|
||
eFaxTxConnecting(3),
|
||
eFaxTxTransmitting(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Status of sending fax session 1."
|
||
::= { faxjob-tx-status 1 }
|
||
|
||
|
||
faxjob-tx-error-1 OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Error status of the fax reception session 1.
|
||
Additional information:
|
||
Error status of the fax transmission session 1."
|
||
::= { faxjob-tx-error 1 }
|
||
|
||
|
||
faxjob-tx-current-page-1 OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The page number of the fax page currently being transmitted via
|
||
send fax session 1. Starts with page number 1."
|
||
::= { faxjob-tx-current-page 1 }
|
||
|
||
|
||
faxjob-rx-current-page-1 OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The page number of the fax page currently being received via
|
||
fax reception session 1. Starts with page number 1."
|
||
::= { faxjob-rx-current-page 1 }
|
||
|
||
|
||
faxjob-rx-duration-1 OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Represent the number of seconds of phone-connect time for a fax
|
||
reception session 1."
|
||
::= { faxjob-rx-duration 1 }
|
||
|
||
|
||
faxjob-tx-duration-1 OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Represent the number of seconds of phone-connect time for send
|
||
fax session 1."
|
||
::= { faxjob-tx-duration 1 }
|
||
|
||
|
||
fax-log-action OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eIdle(1),
|
||
eClear(2),
|
||
ePrintLatest(3),
|
||
ePrintAll(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Provides applications with the ability to clear or print the
|
||
fax transaction log. eIdle - no action is occurring on the fax
|
||
log. eClear - clear the fax log. ePrintLatest - print the
|
||
latest entry in the fax log. ePrintAll - print all the entries
|
||
in the fax log. When this object is set to a non-eIdle value by
|
||
an application, the given action starts. When the action is
|
||
complete, this object is changed back to eIdle by the device. A
|
||
host's request to write this object will be rejected when the
|
||
object is not eIdle. When eIdle, the host may set the object to
|
||
any value (including eIdle)."
|
||
::= { settings-faxlog 1 }
|
||
|
||
|
||
fax-log-reporting OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNever(1),
|
||
eErrorOnly(2),
|
||
eSendOnly(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Specifies when fax transaction logs are to be printed."
|
||
::= { settings-faxlog 2 }
|
||
|
||
|
||
fax-dial-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eToneDial(1),
|
||
ePulseDial(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Device should use DTMF dialing if eToneDial, pulse dial if
|
||
ePulseDial."
|
||
::= { dial-all-lines 1 }
|
||
|
||
|
||
device-redial OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Device to permit redial upon detecting certain error
|
||
conditions."
|
||
::= { dial-all-lines 2 }
|
||
|
||
|
||
fax-pulse-dial-support OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eSupported(1),
|
||
eNotSupported(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object reports whether the current set country supports
|
||
pulse dial.
|
||
Additional information:
|
||
This object reports whether the current set country supports pulse
|
||
dial. In this LaserJet MFP, it checks the DS variable, which is updated
|
||
when the pml object FAX-COUNTRY is changed."
|
||
::= { dial-all-lines 3 }
|
||
|
||
|
||
fax-answer-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eManualAnswer(1),
|
||
eFaxAnswer(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Sets the answering-priority when using a shared voice line.
|
||
eManualAnswer - Device will not automatically answer the phone.
|
||
User must answer and push START button. eFaxAnswer - Device
|
||
should assume call is fax, send CED immediately upon answering.
|
||
eTadAnswer - (Telephone Answering Device Mode) Device allows
|
||
downstream TAD to answer but device will eavesdrop for fax CNG
|
||
signal. If a CNG detected, cut off the downstream device, send
|
||
CED. Do nothing if CNG not detected."
|
||
::= { answer-all-lines 1 }
|
||
|
||
|
||
fax-num-rings-pickup OBJECT-TYPE
|
||
SYNTAX INTEGER(1..6)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Number of rings before the fax device answers the phone if
|
||
FAX-ANSWER-MODE is not set to MANUAL-MODE."
|
||
::= { answer-all-lines 2 }
|
||
|
||
|
||
device-ring-type-pickup OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Device to answer the incoming call based on detecting the the
|
||
specified type of telephone ring."
|
||
::= { answer-all-lines 3 }
|
||
|
||
|
||
fax-receive-stamping-enable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Controls whether or not incoming pages of a fax will be stamped
|
||
upon receipt. Content of the stamp is device-specific but may
|
||
include such information as date, time, fax station name, and
|
||
page number. When this object is set to eEnabled each page of
|
||
an incoming fax is stamped by the device. When this object is
|
||
set to eDisabled incoming fax pages are not stamped.
|
||
Additional information:
|
||
When this object is set to eEnabled each page of an
|
||
incoming fax is stamped with the date, time, fax station
|
||
name, and page number. When this object is set to
|
||
eDisabled incoming fax pages are not stamped.
|
||
//
|
||
The received fax page will be scaled down 0.03% to
|
||
accomodate the header. No header will be printed on
|
||
page 2 of paginated output."
|
||
::= { settings-fax-receive 1 }
|
||
|
||
|
||
not-ready-fax-receive OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates if the receiving fax sub-system in the device is not
|
||
ready. If there are no items in the collection (i.e. no bits
|
||
are set), then the receiving fax sub-system is ready. If there
|
||
is an item present, then the item indicates what is causing the
|
||
receiving fax sub-system to be not ready."
|
||
::= { status-fax-receive 1 }
|
||
|
||
|
||
fax-rxscale OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Received faxes are to be printed at a reduced scale percentage.
|
||
Value of 0 indicates auto-scaled printing based on the length
|
||
of the received fax image and the length of the paper."
|
||
::= { settings-fax-proc-sub 1 }
|
||
|
||
|
||
fax-noise-volume OBJECT-TYPE
|
||
SYNTAX INTEGER(0..200)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest
|
||
possible. A device shall divide this value into ranges
|
||
corresponding to the possible volumes.
|
||
Additional information:
|
||
For this LaserJet MFP the range is 0..200, where 0=off (silent),
|
||
96=soft, 160=medium, and 200=loud.
|
||
|
||
For this LaserJet MFP this object refers to the line monitor
|
||
noise volume. The decimal values above correspond
|
||
to the hex values the object gets set to."
|
||
::= { settings-fax-proc-sub 3 }
|
||
|
||
|
||
fax-download OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFaxDownloadIdle(1),
|
||
eFaxDownloadStart(2),
|
||
eFaxDownloadActive(3),
|
||
eFaxDownloadAborted(4),
|
||
eFaxDownloadDone(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Note: Changed enumeration values in a non-backwards manner in
|
||
version 4.7. Handshake mechanism between host and device to
|
||
initiate and coordinate the download of fax image data to be
|
||
transmitted by the device fax modem. This object serves both as
|
||
an indicator of fax download activity as well as a trigger for
|
||
the host to alter fax download progress. This object has been
|
||
redefined to track only the download acpect of the fax
|
||
transmission.
|
||
eFaxDownloadIdle - indicates no fax download activity is
|
||
occurring. Device powers up in this state but will
|
||
otherwise never transition to this state of its own
|
||
accord. Host setting to eFaxDownloadIdle while object
|
||
is in eFaxDownloadActive will cause download activity
|
||
to be prematurely terminated. Host setting to this
|
||
state resets the handshake mechanism to permit a
|
||
another fax download activity to be initiated.
|
||
eFaxDownloadStart - indicates the host requests to commence
|
||
a download session for sending a fax. This state is
|
||
host settable only from eFaxDownloadIdle. Device will
|
||
never transition to this state of its own accord.
|
||
eFaxDownloadActive - indicates a fax download is occurring.
|
||
This state is not host settable. Device will transition
|
||
to this state from eFaxDownloadStart as a positive
|
||
response for host to commence download of fax data.
|
||
This state is not host settable. The object
|
||
FAXJOB-DOWNLOAD-ID now contains the job ID to be used
|
||
to track the progress of this fax job.
|
||
eFaxDownloadAborted - indicates the fax download activity
|
||
has been prematurely terminated by the device due to
|
||
some error. Object FAX-DOWNLOAD-ERROR contains the
|
||
error reason for the premature session termination.
|
||
This state is device settable from eFaxDownloadStart or
|
||
eFaxDownloadActive. This state is not host settable. If
|
||
modem transmission of fax data has started for this
|
||
download, the fax session will also be aborted.
|
||
eFaxDownloadDone - indicates the fax download activity has
|
||
reached a successful termination in that the device has
|
||
accepted all the download data from the host. This state is
|
||
only settable by the device from eFaxDownloadActive. This state
|
||
is not host settable. This state does not indicate the
|
||
progress of the modem transmission of the downloaded fax data.
|
||
Host should transition from this state to eFaxDownloadIdle in
|
||
order to reset the handshake mechanism for subsequent
|
||
download."
|
||
::= { settings-fax-proc-sub 6 }
|
||
|
||
|
||
fax-silent-detection OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "When enabled, this object causes the FAX machine to assume that
|
||
the caller is a FAX even though the line has remained silent
|
||
for a time (i.e., no CNG detected). When disabled, a CNG is
|
||
required of the caller."
|
||
::= { settings-fax-proc-sub 7 }
|
||
|
||
|
||
fax-ring-enable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "When the phone line rings, this object determines whether an
|
||
audible ring shall be emitted."
|
||
::= { settings-fax-proc-sub 8 }
|
||
|
||
|
||
fax-country OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eChina(6),
|
||
eMexicoAndLatinAmerica(13),
|
||
eCanadaFrench(14),
|
||
eUnitedStatesAndCanadaEnglish(15),
|
||
eNewZealand(19),
|
||
eIsrael(21),
|
||
eAustralia(23),
|
||
eMalaysia(27),
|
||
eHongKong(29),
|
||
eSingapore(30),
|
||
eUnitedKingdom(31),
|
||
eAustria(34),
|
||
eNetherlands(35),
|
||
eSwitzerlandFrench(37),
|
||
eGermany(39),
|
||
eDenmark(40),
|
||
eSweden(41),
|
||
eNorway(43),
|
||
eIreland(44),
|
||
eBelgium(45),
|
||
eFinland(46),
|
||
eFrance(47),
|
||
eItaly(51),
|
||
eSpain(55),
|
||
ePoland(56),
|
||
eHungary(62),
|
||
eUkraine(63),
|
||
eRussia(64),
|
||
eBelarus(66),
|
||
eBrunei(33),
|
||
eCambodia(94),
|
||
eCyprus(95),
|
||
eEgypt(67),
|
||
eEstonia(54),
|
||
eIceland(96),
|
||
eLatvia(53),
|
||
eLiechtentstein(98),
|
||
eLithuania(52),
|
||
eMalta(99),
|
||
eMorocco(65),
|
||
eSaudiArabia(28),
|
||
eTunisia(32),
|
||
eUAE(88)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Note: Non-backwards compatible change make in version 4.7.
|
||
Returns which country the telephone-electronics (LIU) is
|
||
configured for. If this object is implemented with an access of
|
||
read-write the device POS will specify what occurs when this
|
||
object is written."
|
||
::= { settings-fax-proc-sub 9 }
|
||
|
||
|
||
fax-tx-phone-number OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "Phone number about to be dialed."
|
||
::= { settings-fax-proc-sub 10 }
|
||
|
||
|
||
fax-redial-time OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Number of seconds one must wait between the current redial (set
|
||
by FAX-WHICH-REDIAL) and any prior dialing."
|
||
::= { settings-fax-proc-sub 14 }
|
||
|
||
|
||
fax-pstn-access-code OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The code used within a PBX to get access to an outside PSTN
|
||
line. Typically this is ''9''."
|
||
::= { settings-fax-proc-sub 18 }
|
||
|
||
|
||
fax-rx-disposition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePrintOnly(1),
|
||
eUploadOnly(2),
|
||
eUploadElsePrint(4),
|
||
eForwardElsePrint(6)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates what is to be done with the incoming fax call.
|
||
ePrintOnly - New fax arrivals only go to the printer. If
|
||
printer becomes unavailable, the fax is stored in
|
||
device memory until the printer becomes available. If
|
||
device memory becomes full, no subsequent calls will be
|
||
answered. If power is cycled on the device, the user
|
||
must be informed of any lost faxes. If faxes are saved
|
||
in non-volatile memory, then they will be printed upon
|
||
successful power-up.
|
||
eUploadOnly - New fax can only be uploaded to the host. If
|
||
host becomes unavailable, the fax is stored in device
|
||
memory until host becomes available again to upload. If
|
||
device memory becomes full, no subsequent calls will be
|
||
answered. If power is cycled on the device, the user
|
||
must be informed of any lost faxes. If faxes are saved
|
||
in non-volatile device memory, the host must be
|
||
informed of a need to upload saved faxes upon
|
||
successful power up.
|
||
eUploadAndPrint - Received faxes are to be printed and also
|
||
uploaded to the host. The fax is stored in device
|
||
memory until it has been printed and uploaded. If
|
||
device memory becomes full, no subsequent calls will be
|
||
answered. If power is cycled on the device, the user
|
||
must be informed of any lost faxes. If faxes were saved
|
||
into non-volatile memory, then faxes must be printed
|
||
and uploaded before erasure from device memory.
|
||
eUploadElsePrint - Received faxes are to be uploaded if
|
||
host is available, otherwise the fax is printed. During
|
||
an upload, if the host becomes unavailable, the
|
||
remainder of the fax is printed. Once the host is
|
||
detected to be unavailable, the object will transition
|
||
to ePrintOnly. Refer to fax reception behavior for
|
||
ePrintOnly.
|
||
ePrintElseUpload - Received faxes are to be printed. If
|
||
printer is unavailable, the fax will be uploaded. If
|
||
printer becomes unavailable while the fax is being
|
||
received, the remainder unprinted pages of the fax will
|
||
be uploaded. If host then becomes unavailable, this
|
||
object will transition to ePrintOnly. Remainder pages
|
||
of the fax being uploaded will be stored in device
|
||
memory, to be printed when printer becomes available.
|
||
If device memory becomes full, no subsequent calls will
|
||
be answered. If power is cycled on the device, the user
|
||
must be informed of any lost faxes.
|
||
eForwardElsePrint - Received faxes are to be forwarded to
|
||
another fax station. If remote number does not answer,
|
||
fax is printed. If remote number is busy on multiple
|
||
redial attempts, the fax is printed. If device memory
|
||
becomes full before fax reception is complete, the fax
|
||
is printed. If printer becomes unavailable, the fax is
|
||
stored in device memory and then printed when printer
|
||
becomes available again. "
|
||
::= { settings-fax-proc-sub 19 }
|
||
|
||
|
||
fax-error-correction-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates whether the device is configured to send and receive
|
||
faxes in error correction mode (ECM). This object controls both
|
||
receiving and transmitting in ECM. A value of eDisabled means
|
||
ECM is off and the device will not advertise the ability to do
|
||
ECM during negotiation with other fax machines. A value of
|
||
eEnabled means ECM is on and the device will advertise its
|
||
ability to do ECM. Changing this setting may or may not take
|
||
affect on the immediate page or ensuing pages of the document
|
||
currently being sent."
|
||
::= { settings-fax-proc-sub 21 }
|
||
|
||
|
||
fax-report-transmission OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNone(1),
|
||
ePrintReport(2),
|
||
ePrintReportOnSend(3),
|
||
ePrintReportOnError(4),
|
||
ePrintReportOnSendError(5),
|
||
ePrintReportOnReceiveError(6)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Provides a host application with the ability to print a fax
|
||
transmission report. The supported enumerations are:
|
||
eNone - no transmission report printed
|
||
ePrintReport - transmission report always printed
|
||
ePrintReportOnSend - transmission report printed on send
|
||
only
|
||
ePrintReportOnError - transmission report printed on error
|
||
only
|
||
ePrintReportOnSendError - transmission report printed on
|
||
send error only
|
||
ePrintReportOnReceiveError - transmission report printed on
|
||
receive error only. "
|
||
::= { settings-fax-proc-sub 22 }
|
||
|
||
|
||
fax-report-activity-log OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNever(1),
|
||
eThreshold(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Specifies when a report of fax transactions is to be printed.
|
||
|
||
eNever - to never print a transaction report.
|
||
eThreshold - to automatically print a transaction report
|
||
every N transactions.
|
||
|
||
The POS for each product shall specify the value of N.
|
||
|
||
FAX-REPORT-TRANSMISSION also prints a transaction report,
|
||
but for only a given fax, not a log of fax activities.
|
||
May not be settable if the fax machine is not idle.
|
||
|
||
The log is cleared after each printing caused by this
|
||
object. "
|
||
::= { settings-fax-proc-sub 23 }
|
||
|
||
|
||
fax-dial-tone-detection OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Determines whether the fax machine waits for a dial tone before
|
||
dialing a fax number. eEnabled - causes the fax machine to wait
|
||
until a dial tone is recognized before attempting to dial a fax
|
||
number. eDisabled - causes the fax machine to dial without
|
||
waiting to recognize a dial tone."
|
||
::= { settings-fax-proc-sub 24 }
|
||
|
||
|
||
fax-alarm-volume OBJECT-TYPE
|
||
SYNTAX INTEGER(0..3)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest
|
||
possible. A device shall divide this value into ranges
|
||
corresponding to the possible volumes and document these
|
||
settings and their meanings in the product POS.
|
||
Additional information:
|
||
For this LaserJet MFP the range is 0..3, where 0=off (silent),
|
||
1=soft, 2=medium, and 3=loud."
|
||
::= { settings-fax-proc-sub 25 }
|
||
|
||
|
||
fax-beep-volume OBJECT-TYPE
|
||
SYNTAX INTEGER(0..3)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest
|
||
possible. A device shall divide this value into ranges
|
||
corresponding to the possible volumes and document these
|
||
settings and their meanings in the product POS.
|
||
Additional information:
|
||
For this LaserJet MFP the range is 0..3, where 0=off (silent),
|
||
1=soft, 2=medium, and 3=loud."
|
||
::= { settings-fax-proc-sub 26 }
|
||
|
||
|
||
fax-ring-volume OBJECT-TYPE
|
||
SYNTAX INTEGER(0..3)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest
|
||
possible. A device shall divide this value into ranges
|
||
corresponding to the possible volumes and document these
|
||
settings and their meanings in the product POS.
|
||
Additional information:
|
||
For this LaserJet MFP the range is 0..3, where 0=off (silent),
|
||
1=soft, 2=medium, and 3=loud."
|
||
::= { settings-fax-proc-sub 27 }
|
||
|
||
|
||
fax-master-host OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Identifies the hostname of the master host to which the device
|
||
is connected."
|
||
::= { settings-fax-proc-sub 28 }
|
||
|
||
|
||
fax-thumbnail-enable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Controls whether or not a thumbnail reprint of the first page
|
||
of a fax shall be included on the fax call report. When set to
|
||
eEnabled a thumbnail shall be included on the report. When set
|
||
to eDisabled there shall be not be a thumbnail on the fax call
|
||
report.
|
||
Additional information:
|
||
Controls whether or not a thumbnail reprint of the
|
||
first page of a fax shall be included on the
|
||
fax call report. When set to eEnabled a thumbnail shall
|
||
be included on the report. When set to eDisabled there
|
||
shall be not be a thumbnail on the fax call report."
|
||
::= { settings-fax-proc-sub 29 }
|
||
|
||
|
||
fax-phone-pickup-enable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object is included to handle the situation where a fax
|
||
machine and a telephone share the same phone line. If a call
|
||
picked up at the phone turns out to be a fax call, the user may
|
||
initiate a fax receive via the fax machine front panel (with,
|
||
say, a button press). When this object is set to eEnabled and a
|
||
fax call is answered at the phone, the user has the option of
|
||
initiating the fax receive in the usual way at the fax front
|
||
panel or by entering a (product-specific) key sequence on the
|
||
telephone keypad (e.g. '***'). The device POS must indicate
|
||
what the key sequence is for a particular product. When this
|
||
object is set to eDisabled and a fax call is answered at the
|
||
phone, the user may only initiate the fax receive by taking the
|
||
product-specific action (such as a button press) at the fax
|
||
machine front panel. It is necessary to be able to turn this
|
||
feature off (i.e. set it to eDisabled) because the key sequence
|
||
of a particular fax device may interfere with other devices
|
||
connected to the phone line (e.g. an answering machine).
|
||
Additional information:
|
||
On this LaserJet MFP, the key sequence to initiate a fax from the
|
||
phone keypad is '***'."
|
||
::= { settings-fax-proc-sub 30 }
|
||
|
||
|
||
fax-adf-scan-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages scanned for
|
||
faxing from the ADF. In order to write this object
|
||
SERVICE-PASSWORD must be set correctly.
|
||
Additional information:
|
||
This object tracks the page count for the pages scanned for faxing
|
||
from the ADF. In order to write this object SERVICE-PASSWORD must be
|
||
set correctly."
|
||
::= { settings-fax-proc-sub 31 }
|
||
|
||
|
||
fax-print-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages sent to the
|
||
print engine for fax jobs. In order to write this object
|
||
SERVICE-PASSWORD must be set correctly.
|
||
Additional information:
|
||
This object tracks the page count for the pages sent to the print
|
||
engine for fax jobs. In order to write this object SERVICE-PASSWORD
|
||
must be set correctly."
|
||
::= { settings-fax-proc-sub 32 }
|
||
|
||
|
||
fax-download-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages downloaded to
|
||
the peripheral for fax jobs. In order to write this object
|
||
SERVICE-PASSWORD must be set correctly.
|
||
Additional information:
|
||
This object tracks the page count for the pages downloaded to the
|
||
peripheral for fax jobs. In order to write this object SERVICE-PASSWORD
|
||
must be set correctly."
|
||
::= { settings-fax-proc-sub 33 }
|
||
|
||
|
||
fax-upload-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages uploaded from
|
||
the peripheral for fax jobs. In order to write this object
|
||
SERVICE-PASSWORD must be set correctly.
|
||
Additional information:
|
||
This object tracks the page count for the pages uploaded from the
|
||
peripheral for fax jobs. In order to write this object SERVICE-PASSWORD
|
||
must be set correctly."
|
||
::= { settings-fax-proc-sub 34 }
|
||
|
||
|
||
fax-flatbed-scan-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages scanned for
|
||
faxing from the flatbed. In order to write this object the
|
||
SERVICE-PASSWORD must be set.
|
||
Additional information:
|
||
This object tracks the page count for the pages scanned
|
||
for faxing from the flatbed. In order to write this
|
||
object the SERVICE-PASSWORD must be set."
|
||
::= { settings-fax-proc-sub 36 }
|
||
|
||
|
||
default-fax-glass-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eISOandJISA4(26)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the default fax glass size.
|
||
Additional information:
|
||
Indicates the default fax glass size."
|
||
::= { settings-fax-proc-sub 37 }
|
||
|
||
|
||
fax-cold-reset-fax-glass-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eISOandJISA4(26)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the fax glass size that is used as the
|
||
DEFAULT-FAX-GLASS-SIZE when a cold reset occurs.
|
||
Additional information:
|
||
Returns or sets the fax glass size that is used as the
|
||
DEFAULT-FAX-GLASS-SIZE when a cold reset occurs."
|
||
::= { settings-fax-proc-sub 38 }
|
||
|
||
|
||
fax-upload OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFaxUploadIdle(1),
|
||
eFaxUploadStart(2),
|
||
eFaxUploadActive(3),
|
||
eFaxUploadAborted(4),
|
||
eFaxUploadDone(5),
|
||
eFaxUploadNeeded(6)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Note: The enumeration values for this object where changed in a
|
||
non-backwards compatible manner in version 4.7. Handshake
|
||
mechanism between host and device to notify and coordinate the
|
||
transfer of fax image data received by the device fax modem.
|
||
This object serves both as an indicator of fax upload activity
|
||
as well as a trigger for the host to alter fax upload progress.
|
||
Handshake mechanism between host and device to initiate scan
|
||
operation and coordinate the transfer of scanned image data to
|
||
the host. This object serves both as an indicator of scan
|
||
upload activity as well as a trigger for the host to alter scan
|
||
upload progress.
|
||
eFaxUploadIdle - indicates no fax upload activity is is
|
||
occurring. Device powers up in this state but will
|
||
otherwise never transition to this state of its own
|
||
accord. Host setting to eFaxUploadIdle while object is
|
||
in eFaxUploadActive will cause download activity to be
|
||
prematurely terminated. Host setting to this state
|
||
resets the handshake mechanism to permit another fax
|
||
upload activity to be initiated.
|
||
eFaxUploadStart - indicates the host requests to commence
|
||
an upload session for a received fax. This state is
|
||
host settable only from eFaxUploadIdle. Device will
|
||
never transition to this state of its own accord.
|
||
eFaxUploadActive - indicates a fax upload is occurring.
|
||
This state is not host settable. Device will transition
|
||
to this state from eFaxUploadStart as a positive
|
||
response for host to commence upload of fax data. The
|
||
object FAXJOB-UPLOAD-ID now contains the job ID.
|
||
eFaxUploadAborted - indicates the fax upload activity has
|
||
been prematurely terminated by the device due to some
|
||
error. Object FAX-UPLOAD-ERROR contains the error
|
||
reason for the premature session termination. This
|
||
state is device settable from eFaxUploadStart,
|
||
eFaxUploadActive or eFaxUploadNeeded. This state is not
|
||
host settable.
|
||
eFaxUploadDone - indicates the fax upload activity has
|
||
reached a successful termination in that the device has
|
||
transmitted all the upload data to the host. This state
|
||
is only settable by the device from eFaxUploadActive.
|
||
This state is not host settable. Host should transition
|
||
from this state to eFaxUploadIdle in order to reset the
|
||
handshake mechanism for subsequent upload session.
|
||
eFaxUploadNeeded - indicates device has received fax modem
|
||
data available for host upload. This state is not host
|
||
settable. This state is device settable from
|
||
eFaxUploadIdle. Host should respond by setting to
|
||
eFaxUploadStart to initiate upload session. Should host
|
||
fail to respond by the time fax reception is complete
|
||
or device has exhausted local memory storage, device
|
||
shall transition object from eFaxUploadNeeded to
|
||
eFaxUploadAborted. The POS should state the recourse
|
||
behavior associated with the received fax. "
|
||
::= { status-fax-proc-sub 1 }
|
||
|
||
|
||
fax-min-rings-pickup OBJECT-TYPE
|
||
SYNTAX INTEGER(1..1)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the minimum legal rings before pickup."
|
||
::= { status-fax-proc-sub 2 }
|
||
|
||
|
||
fax-max-rings-pickup OBJECT-TYPE
|
||
SYNTAX INTEGER(1..10)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the maximum legal rings before pickup."
|
||
::= { status-fax-proc-sub 3 }
|
||
|
||
|
||
fax-max-redials OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Maximum number of allowed redials."
|
||
::= { status-fax-proc-sub 4 }
|
||
|
||
|
||
fax-additional-wait OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Number of additional seconds to wait before beginning a
|
||
FAX-DOWNLOAD."
|
||
::= { status-fax-proc-sub 5 }
|
||
|
||
|
||
fax-download-error OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Error status of the fax download session."
|
||
::= { status-fax-proc-sub 6 }
|
||
|
||
|
||
fax-upload-error OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Error status of the fax upload session."
|
||
::= { status-fax-proc-sub 7 }
|
||
|
||
|
||
fax-firmware-revision OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(8))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object identifies the fax firmware ROM revision code. The
|
||
format is device specific and shall be specified in the device
|
||
POS.
|
||
Additional information:
|
||
This object identifies the fax firmware ROM revision
|
||
code. For this LaserJet MFP, the format for this object is a date
|
||
in the form YYYYMMDD."
|
||
::= { status-fax-proc-sub 8 }
|
||
|
||
|
||
fax-forwarding-phone-num OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Phone number digits of the remote fax station where arrived
|
||
faxes are to be forwarded."
|
||
::= { fax-forwarding 3 }
|
||
|
||
|
||
fax-resolution OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..64))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "struct {
|
||
unsigned_32bit x_res; /* 1st four bytes; big endian */
|
||
unsigned_32bit y_res; /* 2nd four bytes; big endian */
|
||
}
|
||
Sets the send fax resolution. The x and y resolutions in
|
||
this object are in fixed-point with 16 bits of
|
||
fraction, and 16 bits of integer, and are in dots per
|
||
inch. X is horizontal; Y is vertical. Examples of
|
||
computing x_res and y_res: 300 dots/inch:round(300 *
|
||
65536) = 19660800
|
||
16 dots/mm: round(16 *25.4 * 65536) = 26633830.
|
||
If the device does not support the given combination, then
|
||
it'll select the nearest supported values in a device-dependent
|
||
manner (documented in the POS).
|
||
Additional information:
|
||
This LaserJet MFP supports 4 fax resolutions. As far as the
|
||
end-user is concerned these resolutions are: standard,
|
||
fine, superfine, and photo. Photo is not really a
|
||
resolution--see more below. Standard is the default.
|
||
Resolutions map as follows (values are given in dots per
|
||
inch (dpi) horizontal X vertical (x X y)): standard(203
|
||
X 98), fine(203 X 196), superfine(300 X 300), and
|
||
photo(300 X 300).
|
||
|
||
Supported resolutions in hex notation (dpi, x X y) are:
|
||
standard(00cb0000 X 00620000), fine(00cb0000 X 00c4000),
|
||
superfine(012C0000 X 012C0000), and photo(012C0000 X
|
||
012C0000).
|
||
|
||
The device ignores attempts to set invalid resolutions.
|
||
|
||
Photo is not a resolution, but photo setting depends on
|
||
whether half-toning is on or off. In the case of this LaserJet MFP
|
||
photo setting doesn't actually change the bits going out
|
||
the modem -- still one bit per pixel so photo and
|
||
superfine are the same.
|
||
|
||
NOTE: The last 16 bits of the horizontal and vertical
|
||
settings are ignored. Only the first 16 bits of the
|
||
horizontal and vertical resolution setting are used."
|
||
::= { settings-fax-send 1 }
|
||
|
||
|
||
fax-contrast OBJECT-TYPE
|
||
SYNTAX INTEGER(-127..127)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
|
||
used for setting the sending fax contrast level. Range is
|
||
0..100.
|
||
Additional information:
|
||
Behaves as COPIER-CONTRAST and SCANNER-CONTRAST.
|
||
Contrast values can range from -127 to +127, for a total
|
||
of 255 contrast values. Within that range, this LaserJet MFP
|
||
supports 11 values. They are: -125, -100, -75, -50,
|
||
-25, 0, 25, 50, 75, 100, 125. The default contrast level is 0
|
||
(normal). A positive value results in a larger
|
||
difference, and a negative value results in a smaller
|
||
difference.
|
||
|
||
This LaserJet MFP snaps unsupported values toward zero as follows:
|
||
<=-125 snaps to -125
|
||
>-125 and <=-100 snaps to -100
|
||
>-100 and <=-75 snaps to -75
|
||
>-75 and <=-50 snaps to -50
|
||
>-50 and <=-25 snaps to -25
|
||
>-25 and <25 snaps to 0
|
||
>=25 and <50 snaps to 25
|
||
>=50 and <75 snaps to 50
|
||
>=75 and <100 snaps to 75
|
||
>=100 and <125 snaps to 100
|
||
>=125 snaps to 125"
|
||
::= { settings-fax-send 2 }
|
||
|
||
|
||
fax-pixel-data-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eBiLevelThesholded(1),
|
||
eBiLevelHalfToned(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Sets the scanning method used when sending a fax.
|
||
eBiLevelThesholded - One bit per pixel, using simple
|
||
thresholding of greyscale scan data. eBiLevelHalfToned - One
|
||
bit per pixel, using some kind of half-toning technique (such
|
||
as dithering or error-diffusion) to approximate greyscale scan
|
||
data."
|
||
::= { settings-fax-send 3 }
|
||
|
||
|
||
not-ready-fax-send OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates if the sending fax sub-system in the device is not
|
||
ready. If there are no items in the collection (i.e. no bits
|
||
are set), then the sending fax sub-system is ready. If there is
|
||
an item present, then the item indicates what is causing the
|
||
sending fax sub-system to be not ready."
|
||
::= { status-fax-send 1 }
|
||
|
||
|
||
fax-allow-redials OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(1),
|
||
eTrue(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "When eTrue, the FAX machine can redial a phone number if the
|
||
prior call failed for some reason. When eFalse, such redialing
|
||
will not occur.
|
||
Additional information:
|
||
This object is not used for this LaserJet MFP products."
|
||
::= { transmit-fax 3 }
|
||
|
||
|
||
hrMemorySize OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The amount of physical main memory contained by
|
||
the host.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The unit of measure for this object is 1024
|
||
bytes. The default value for Kiwi imaging and Raptor with no
|
||
additional memory. Kiwi base (lite) only has 131072 (128 megs)"
|
||
::= { hrStorage 2 }
|
||
|
||
|
||
hrStorageIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each logical storage area
|
||
contained by the host.
|
||
Refer to RFC 1514, Host Resources MIB, for more details."
|
||
::= { hrStorageEntry 1 }
|
||
|
||
|
||
hrStorageType OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The type of storage represented by this entry.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The object is constant for the product."
|
||
::= { hrStorageEntry 2 }
|
||
|
||
|
||
hrStorageDescr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A description of the type and instance of the
|
||
storage described by this entry.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This object is not localized. For the product, this
|
||
object is constant."
|
||
::= { hrStorageEntry 3 }
|
||
|
||
|
||
hrStorageAllocationUnits OBJECT-TYPE
|
||
SYNTAX INTEGER(1..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The size, in bytes, of the data objects allocated
|
||
from this pool. If this entry is monitoring
|
||
sectors, blocks, buffers, or packets, for example,
|
||
this number will commonly be greater than one.
|
||
Otherwise this number will typically be one.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Unit is one byte. For the product,
|
||
this object is constant."
|
||
::= { hrStorageEntry 4 }
|
||
|
||
|
||
hrStorageSize OBJECT-TYPE
|
||
SYNTAX INTEGER(0..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The size of the storage represented by this entry,
|
||
in units of hrStorageAllocationUnits.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
Total formatter RAM. (The value of this object
|
||
is hrMemorySize times the unit of measure for hrMemorySize.
|
||
For Kiwi imaging , Raptor and Kiwi base (lite) this is
|
||
131072*1024 (134217728) bytes)"
|
||
::= { hrStorageEntry 5 }
|
||
|
||
|
||
hrStorageUsed OBJECT-TYPE
|
||
SYNTAX INTEGER(0..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The amount of the storage represented by this
|
||
entry that is allocated, in units of
|
||
hrStorageAllocationUnits.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This object returns the amount of memory in use
|
||
by the printer at the current time. This object should not
|
||
be used when creating a print job for the device because the
|
||
amount of memory in use will likely be different when the
|
||
printer processes the print job."
|
||
::= { hrStorageEntry 6 }
|
||
|
||
|
||
hrStorageAllocationFailures OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The number of requests for storage represented by
|
||
this entry that could not be honored due to not
|
||
enough storage. It should be noted that as this
|
||
object has a SYNTAX of Counter, that it does not
|
||
have a defined initial value. However, it is
|
||
recommended that this object be initialized to
|
||
zero.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This object is set to zero at power on and when
|
||
any reset is done via prtGeneralReset.
|
||
This object is incremented whenever the printer is short on
|
||
memory (codewise: when PersMemoryCycle is called with a
|
||
parameter of 2)."
|
||
::= { hrStorageEntry 7 }
|
||
|
||
|
||
hrDeviceIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..2147483647)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A unique value for each device contained by the
|
||
host. The value for each device must remain
|
||
constant at least from one re-initialization of the
|
||
agent to the next re-initialization.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The entry in the Device Table which describes
|
||
the printer."
|
||
::= { hrDeviceEntry 1 }
|
||
|
||
|
||
hrDeviceType OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "An indication of the type of device.
|
||
If this value is `hrDeviceProcessor { hrDeviceTypes
|
||
3 }' then an entry exists in the hrProcessorTable
|
||
which corresponds to this device.
|
||
If this value is `hrDeviceNetwork { hrDeviceTypes 4
|
||
}', then an entry exists in the hrNetworkTable
|
||
which corresponds to this device.
|
||
If this value is `hrDevicePrinter { hrDeviceTypes 5
|
||
}', then an entry exists in the hrPrinterTable
|
||
which corresponds to this device.
|
||
If this value is `hrDeviceDiskStorage {
|
||
hrDeviceTypes 6 }', then an entry exists in the
|
||
hrDiskStorageTable which corresponds to this
|
||
device.
|
||
Refer to RFC 1514, Host Resources MIB, for more details."
|
||
::= { hrDeviceEntry 2 }
|
||
|
||
|
||
hrDeviceDescr OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "A textual description of this device, including
|
||
the device's manufacturer and revision, and
|
||
optionally, its serial number.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The serial number is not returned with this
|
||
object. This object is not localized."
|
||
::= { hrDeviceEntry 3 }
|
||
|
||
|
||
hrDeviceID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The product ID for this device.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The DEFAULT for Kiwi is {kiwi} and the complete ID is:
|
||
1.3.6.1.4.1.11.2.3.9.1.2.88.2
|
||
The DEFAULT for Raptor is {raptor}:
|
||
1.3.6.1.4.1.11.2.3.9.1.2.89.2"
|
||
::= { hrDeviceEntry 4 }
|
||
|
||
|
||
hrDeviceStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHrunning(2),
|
||
eHwarning(3),
|
||
eHdown(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current operational state of the device
|
||
described by this row of the table. A value
|
||
unknown(1) indicates that the current state of the
|
||
device is unknown. running(2) indicates that the
|
||
device is up and running and that no unusual error
|
||
conditions are known. The warning(3) state
|
||
indicates that agent has been informed of an
|
||
unusual error condition by the operational software
|
||
(e.g., a disk device driver) but that the device is
|
||
still 'operational'. An example would be high
|
||
number of soft errors on a disk. A value of
|
||
testing(4), indicates that the device is not
|
||
available for use because it is in the testing
|
||
state. The state of down(5) is used only when the
|
||
agent has been informed that the device is not
|
||
available for any use.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The printer's condition is mapped as follows:
|
||
|
||
eHrunning -- Printer ready to print or is printing. It may
|
||
be in power save mode.
|
||
|
||
eHwarning -- A condition exists that needs attention, but it
|
||
is not currently preventing printing. A non-critical alert
|
||
is active.
|
||
|
||
eHdown -- Printer is not printing because it is offline, or
|
||
a critical alert is active. Human interaction is needed to
|
||
bring the printer to a ready state."
|
||
::= { hrDeviceEntry 5 }
|
||
|
||
|
||
hrDeviceErrors OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The number of errors detected on this device. It
|
||
should be noted that as this object has a SYNTAX
|
||
of Counter, that it does not have a defined
|
||
initial value. However, it is recommended that
|
||
this object be initialized to zero.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
This is the number of critical alerts that have
|
||
been entered into the alert table since the device was
|
||
powered on. The maximum value for this object is 2^32-1. At
|
||
power-on, this object will be set to zero."
|
||
::= { hrDeviceEntry 6 }
|
||
|
||
|
||
hrPrinterStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eHother(1),
|
||
eHidle(3),
|
||
eHprinting(4),
|
||
eHwarmup(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "The current status of this printer device. When
|
||
in the idle(1), printing(2), or warmup(3) state,
|
||
the corresponding hrDeviceStatus should be
|
||
running(2) or warning(3). When in the unknown
|
||
state, the corresponding hrDeviceStatus should be
|
||
unknown(1).
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The printer's condition is mapped as follows:
|
||
|
||
eHother -- The printer is offline, or a critical alert is
|
||
active.
|
||
|
||
eHidle -- The printer is not performing any of the items
|
||
listed under eHprinting status.
|
||
|
||
eHprinting -- A job is currently being processed or printed,
|
||
or a PJL job is being processed.
|
||
|
||
eHwarmup -- If hrDeviceStatus is eHdown, the printer is
|
||
currently offline but is resolving the condition that caused
|
||
it to be offline. It will be online when it is ready to
|
||
print. If hrDeviceStatus is eHrunning, the printer was
|
||
in power save mode and is now becoming ready to print. (In
|
||
the product, this status only occurs very
|
||
briefly at boot time. At no other time does the printer
|
||
report 'eHwarmup' status.)"
|
||
::= { hrPrinterEntry 1 }
|
||
|
||
|
||
hrPrinterDetectedErrorState OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION "This object represents any error conditions
|
||
detected by the printer. The error conditions are
|
||
encoded as bits in an octet string, with the
|
||
following definitions:
|
||
Condition Bit # hrDeviceStatus
|
||
lowPaper 0 warning(3)
|
||
noPaper 1 down(5)
|
||
lowToner 2 warning(3)
|
||
noToner 3 down(5)
|
||
doorOpen 4 down(5)
|
||
jammed 5 down(5)
|
||
offline 6 down(5)
|
||
serviceRequested 7 warning(3)
|
||
If multiple conditions are currently detected and
|
||
the hrDeviceStatus would not otherwise be
|
||
unknown(1) or testing(4), the hrDeviceStatus shall
|
||
correspond to the worst state of those indicated,
|
||
where down(5) is worse than warning(3) which is
|
||
worse than running(2).
|
||
Bits are numbered starting with the most
|
||
significant bit of the first byte being bit 0, the
|
||
least significant bit of the first byte being bit
|
||
7, the most significant bit of the second byte
|
||
being bit 8, and so on. A one bit encodes that
|
||
the condition was detected, while a zero bit
|
||
encodes that the condition was not detected.
|
||
This object is useful for alerting an operator to
|
||
specific warning or error conditions that may
|
||
occur, especially those requiring human
|
||
intervention.
|
||
Refer to RFC 1514, Host Resources MIB, for more details.
|
||
Additional information:
|
||
The product reports error
|
||
conditions as follows:
|
||
|
||
noPaper - A tray is empty and must be filled for printing to
|
||
continue.
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
A critical alert is active.
|
||
|
||
coverOpen -- A cover or door is open.
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
A critical alert is active.
|
||
|
||
jammed -- A jam condition is preventing printing.
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
A critical alert is active.
|
||
|
||
offline -- Printer is offline and will not accept new print
|
||
jobs until it is online. This condition is rare in the
|
||
and may indicate some other error.
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
A critical alert is active.
|
||
|
||
serviceRequested -- Any status or error condition not listed
|
||
above. These fall into two categories:
|
||
(1) If the condition prevents printing, the 'offline' bit
|
||
is also set and status values are as for offline. i.e.:
|
||
hrDeviceStatus = eHdown;
|
||
hrPrinterStatus = eHother;
|
||
A critical alert is active.
|
||
(2) If the condition does not prevent printing the status
|
||
values are:
|
||
hrDeviceStatus = eHwarning;
|
||
hrPrinterStatus = eHidle or eHprinting;
|
||
A non-critical alert is active.
|
||
|
||
lowToner -- The product can report this condition.
|
||
|
||
noToner -- The product can report this condition."
|
||
::= { hrPrinterEntry 2 }
|
||
|
||
|
||
npCRCTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF NpCRCEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION ""
|
||
::= { npCard 15 }
|
||
|
||
|
||
npCRCEntry OBJECT-TYPE
|
||
SYNTAX NpCRCEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION ""
|
||
::= { npCRCTable 1 }
|
||
|
||
|
||
npCRCIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION ""
|
||
::= { npCRCEntry 1 }
|
||
|
||
|
||
npCRCText OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION ""
|
||
::= { npCRCEntry 2 }
|
||
|
||
|
||
npCRCChannel OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION ""
|
||
::= { npCRCEntry 3 }
|
||
|
||
|
||
inetTrapDestinationNum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Total number of ACTIVE rows in the inetTrapDestination table."
|
||
::= { inetTrapDestination 1 }
|
||
|
||
|
||
inetTrapDestinationTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF InetTrapDestinationEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "List of inetTrap destinations to which the agent sends traps."
|
||
::= { inetTrapDestination 2 }
|
||
|
||
|
||
inetTrapDestinationEntry OBJECT-TYPE
|
||
SYNTAX InetTrapDestinationEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Entries are inetAddress Specific sequence of trap destination parameters."
|
||
::= { inetTrapDestinationTable 1 }
|
||
|
||
|
||
inetTrapRowIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Row Index of the inetTrapDestination table"
|
||
::= { inetTrapDestinationEntry 1 }
|
||
|
||
|
||
inetTrapRowStatus OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Individual Row Status
|
||
1 - Row is Active - Row is activated and ready.
|
||
2 - Not-In-Service - Row is suspended.
|
||
3 - Not Ready - Row is not activated and still needs some columnar values to move to ready state.
|
||
4 - Create and Go - This is set when the client uses multivarbind request to configure the trap table.
|
||
5 - Create and Wait - This is set when the client does sequential configuration of the trap table.
|
||
6 - Destroy - This is set when the client wants to delete the row from the table.
|
||
"
|
||
::= { inetTrapDestinationEntry 2 }
|
||
|
||
|
||
inetTrapAddressType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Protocol family for trap. Possible values:
|
||
ipv4(1) An IPv4 address as defined by the
|
||
InetAddressIPv4 textual convention.
|
||
|
||
ipv6(2) An IPv6 address as defined by the
|
||
InetAddressIPv6 textual convention.
|
||
|
||
dns(16) A DNS domain name as defined by the
|
||
InetAddressDNS textual convention."
|
||
::= { inetTrapDestinationEntry 3 }
|
||
|
||
|
||
inetTrapAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "IPv4/IPv6/FQDN address of trap destination node."
|
||
::= { inetTrapDestinationEntry 4 }
|
||
|
||
|
||
inetTrapPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Port number of the inetTrap Destination to which the trap is sent."
|
||
::= { inetTrapDestinationEntry 5 }
|
||
|
||
|
||
inetTrapCommunityName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Trap community name specified in the trap packet."
|
||
::= { inetTrapDestinationEntry 6 }
|
||
|
||
|
||
inetTrapVersion OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Trap version, one of the following
|
||
0 = snmpV1
|
||
1 = snmpV2
|
||
3 = Inform
|
||
Default is 1 = snmpV2.
|
||
This value remains persistent through a powercycle."
|
||
::= { inetTrapDestinationEntry 7 }
|
||
|
||
|
||
inetTrapStyle OBJECT-TYPE
|
||
SYNTAX INTEGER {selectable-pml-traps(1),
|
||
aps-and-general-or-nrdpe-traps(2),
|
||
both-of-the-above(3)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This OID is read-write.
|
||
If the user wants to receive only the PML traps, then trapStyle can be set to 1.
|
||
If the user wants to receive only APS and General or NOT-READY-DESTINATION-PRINT-ENGINE traps, then trapStyle can be set to 2.
|
||
If the user wants to receive the both kinds of above traps, then trapStyle can be set to 3."
|
||
::= { inetTrapDestinationEntry 8 }
|
||
|
||
|
||
inetTrapPMLOids OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This OID is a read-write. This will have tokens of PML trappable OIDs.
|
||
Each token (OID) will be separated by a semi-colon. If a trap destination entry is
|
||
registered for only APS and general/NRDPE traps, then the pmlTrapOids OID will be a NULL string."
|
||
::= { inetTrapDestinationEntry 9 }
|
||
|
||
|
||
inetTrapErrorValue OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Gives the error value in case if the server is not able to send the traps
|
||
to the configured trapDestination entry. It will be set to below defined error values
|
||
if there the agent finds any error while dispatching a trap.
|
||
|
||
10 - Invalid value for rowStatus. Should be 1, 2, 3 or 6.
|
||
11 - Ivalid value for InetTrapAddressType. Should be 1, 2 or 16.
|
||
12 - Invalid for IP Address or FQDN.
|
||
13 - Ivalid value for inetTrapPort. Should be greater than 0 or less than 65536.
|
||
14 - Invalid valur for inetTrapCommunityName.
|
||
15 - Invalid value for inetTrapVersion. Should be 0, 1 or 3.
|
||
16 - Invalid value for inetTrapStyle. Should be either 1, 2 or 3.
|
||
17 - Unable to resgister SOME or ALL PML trappable OIDs.
|
||
|
||
51 - InetTrapAddressType & InetTrapAddress does not macth.
|
||
52 - It is a Duplicate entry.
|
||
53 - Unable to move the row to ACTIVE state because of insufficient/invalid entries.
|
||
|
||
80 - Unable to resolve name: no DNS server.
|
||
81 - Unable to resolve name: no DNS records present for name.
|
||
82 - Unable to resolve name: no dns records matching FQDN Resolution Value.
|
||
"
|
||
::= { inetTrapDestinationEntry 10 }
|
||
|
||
|
||
inetTrapTest OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION "Causes agent to send an snmp trap to hosts registered in the trap
|
||
destination table. Value specified will be used as the specific
|
||
trap id."
|
||
::= { inetTrapDestination 3 }
|
||
|
||
|
||
inetTrapFilterDelay OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The purpose of the trap filter feature is to prevent multiple traps
|
||
of the same specificTrapId to be sent within a short period of time.
|
||
This object assigns the period of time within which a duplicate trap
|
||
will be blocked. This value is in 1/10 second intervals and the default
|
||
value is set to 50 corresponding to 5 seconds.
|
||
This value remains persistent through a powercycle."
|
||
::= { inetTrapDestination 4 }
|
||
|
||
|
||
inetTrapBaseTimeout OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Applicable only if trapVersion is set to Inform.
|
||
Units are 1/10 second intervals. Default is 2
|
||
corresponding to 200 milliseconds. This value corresponds
|
||
to the time of the first retry following the initial inform
|
||
request. Additional retries are sent at times corresponding to
|
||
the retry number multiplied by the inetTrapBaseTimeout.
|
||
This value remains persistent through a powercycle."
|
||
::= { inetTrapDestination 5 }
|
||
|
||
|
||
inetTrapRetryNum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Applicable only if trapVersion is set to Inform.
|
||
This is the maximum number of inform retries that will be sent to
|
||
this destination. Retries are sent if no inform reply is received
|
||
within the timeout value. The timeout value is calculated as
|
||
described under inetTrapBaseTimeout.
|
||
This value remains persistent through a powercycle."
|
||
::= { inetTrapDestination 6 }
|
||
|
||
|
||
inetTrapFQDNResolution OBJECT-TYPE
|
||
SYNTAX INTEGER {resolve-for-IPv4-address(1),
|
||
resolve-for-IPv6-address(2),
|
||
resolve-for-both(10)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The purpose of this field is to configure various options for resolving FQDN.
|
||
If configured as 1 - then FQDN names will be resolved for IPv4 addresses only
|
||
If configured as 2 - then FQDN names will be resolved for IPv6 addresses only.
|
||
If configured as 10 - then FQDN names will be resolved for both IPv4 and IPv6 addresses."
|
||
::= { inetTrapDestination 7 }
|
||
|
||
|
||
inetTrapFQDNMultipleAddressBehavior OBJECT-TYPE
|
||
SYNTAX INTEGER {send-to-first-resolved-address(1),
|
||
send-to-all-resolved-address(2)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "1 - Send traps to the first resolved address
|
||
2 - Send traps to all resolved address.
|
||
"
|
||
::= { inetTrapDestination 8 }
|
||
|
||
|
||
inetTrapUseDNSCache OBJECT-TYPE
|
||
SYNTAX INTEGER {enable(1),
|
||
disable(0)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Depending upon the value of this field resolution of FQDN will happen everytime when a trap is sent."
|
||
::= { inetTrapDestination 9 }
|
||
|
||
|
||
trapDestinationNum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The number of trap destinations."
|
||
::= { trapDest 1 }
|
||
|
||
|
||
trapDestinationTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF TrapDestinationEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Protocol specific list of destinations
|
||
to which the agent sends traps."
|
||
::= { trapDest 2 }
|
||
|
||
|
||
trapDestinationEntry OBJECT-TYPE
|
||
SYNTAX TrapDestinationEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Entries are a protocol specific sequence of trap
|
||
destination parameters."
|
||
::= { trapDestinationTable 1 }
|
||
|
||
|
||
trapTest OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Causes agent to send an snmp trap to hosts registered in the trap
|
||
destination table. Value specified will be used as the specific
|
||
trap id."
|
||
::= { trapDest 3 }
|
||
|
||
|
||
trapSource OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Sets the agent internal source for traps. Possibilities are as follows:
|
||
0 = ALL_TRAPS_ON
|
||
1 = ASYNC_PERIPHERAL_STATUS traps only
|
||
2 = proprietary PML traps only
|
||
3 = alert table traps only
|
||
|
||
This object was changed to read-only to accommodate the SNMPv3
|
||
Notifiaction tables requirement to recieve all traps. SNMPv3 tags
|
||
are used to filter SNMP Trap sources."
|
||
::= { trapDest 4 }
|
||
|
||
|
||
trapFilterDelay OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The purpose of the trap filter feature is to prevent multiple traps
|
||
of the same specificTrapId to be sent within a short period of time.
|
||
This object assigns the period of time within which a duplicate trap
|
||
will be blocked. This value is in 1/10 second intervals and the default
|
||
value is set to 50 corresponding to 5 seconds. This value remains
|
||
persistent
|
||
through a powercycle."
|
||
::= { trapDest 5 }
|
||
|
||
|
||
trapFQDNNum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Number of trapFQDNTable rows."
|
||
::= { trapDest 6 }
|
||
|
||
|
||
trapFQDNTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF TrapFQDNEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "The trap destination entries can be mapped to destination's FQDN name in this table."
|
||
::= { trapDest 7 }
|
||
|
||
|
||
trapFQDNEntry OBJECT-TYPE
|
||
SYNTAX TrapFQDNEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "An FQDN destination entry indexed by the destination's IP address."
|
||
::= { trapFQDNTable 1 }
|
||
|
||
|
||
trapIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The trap destination IP address."
|
||
::= { trapFQDNEntry 1 }
|
||
|
||
|
||
trapFQDN OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The trap destination's FQDN. This will be resolved to IP address(es) at trap destination time."
|
||
::= { trapFQDNEntry 2 }
|
||
|
||
|
||
setCommunityName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This object controls access of snmp read-write requests. Factory
|
||
default configuration provides authentication of incoming packets
|
||
with community names: internal and public. This object overrides the
|
||
factory default settings so that the factory default setttings no longer
|
||
work. This object returns SET or NOT_SET."
|
||
::= { community 1 }
|
||
|
||
|
||
getCommunityName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This object controls access of snmp read requests. Factory
|
||
default configuration provides authentication of incoming packets
|
||
with community names: internal and public. This object provides
|
||
access in addition to the factory default settings. If
|
||
set, then authentication will succeed with any of the following
|
||
community names: internal, public, getCommunityName, or
|
||
setCommunityName. This object returns SET or NOT_SET."
|
||
::= { community 2 }
|
||
|
||
|
||
npSysStatusMessage OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "A status string reflecting the current state of the card
|
||
and peripheral."
|
||
::= { npSys 2 }
|
||
|
||
|
||
npSysModelNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The HP model number of the device."
|
||
::= { npSys 10 }
|
||
|
||
|
||
npSysNetworkConnectors OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This object describes the network connectors supported by the
|
||
device. The value is a bit mask. A set bit indicates the
|
||
connector is supported.
|
||
Bit Value Connector
|
||
0 0x01 Ethernet, BNC
|
||
1 0x02 Ethernet, AUI
|
||
2 0x04 Ethernet, RJ-45
|
||
3 0x08 TokenRing, DB-9
|
||
4 0x10 TokenRing, RJ-45
|
||
5 0x20 LocalTalk
|
||
6 0x40 100VG, RJ-45
|
||
7 0x80 100T, RJ-45"
|
||
::= { npSys 11 }
|
||
|
||
|
||
npSysCardServices1 OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This object is a bitmap showing what services are available
|
||
on the card.
|
||
|
||
Bit 0 - IPX/SPX/NCP protocol stack
|
||
Bit 1 - IP/TCP protocol stack
|
||
Bit 2 - LLC/DLC protocol stack
|
||
Bit 3 - Ethertalk protocol stack
|
||
Bit 4 - IPv6 protocol stack
|
||
Bit 5 - IPSec protocol stack
|
||
Bits 6 - 11 Reserved
|
||
Bit 12 - LPD print services
|
||
Bit 13 - FTP print services
|
||
Bit 14 - Port 9100 print services
|
||
Bit 15 - IPP print services
|
||
Bits 16 - 23 Reserved
|
||
Bit 24 - Queue Server Bindery
|
||
Bit 25 - Queue Server NDS
|
||
Bit 26 - Remote Printer
|
||
Bit 27 - SPX Direct Mode
|
||
Bit 28 - DLC Print Services
|
||
Bit 29 - EtherTalk Print Services
|
||
Bits 30 - 31 Reserved"
|
||
::= { npSys 16 }
|
||
|
||
|
||
npSysCardServices2 OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This object is a bitmap showing what services are available
|
||
on the card.
|
||
|
||
Bit 0 - XIP2
|
||
Bit 1 - PML Get/Set
|
||
Bit 2 - PML Traps
|
||
Bit 3 - Scan to Web Browser
|
||
Bit 4 - Scan to Email
|
||
Bit 5 - MFP Scan Support
|
||
Bits 6 - 11 Reserved
|
||
Bit 12 - Telnet API
|
||
Bit 13 - Web API
|
||
Bit 14 - SNMP V2
|
||
Bit 15 - SNMP Traps
|
||
Bit 16 - Download
|
||
Bit 17 - TFTP
|
||
Bit 18 - RCFG
|
||
Bit 19 - SLP
|
||
Bit 20 - Syslog
|
||
Bit 21 - DHCP
|
||
Bit 22 - BOOTP
|
||
Bit 23 - RARP
|
||
Bit 24 - SNMP V3
|
||
Bit 25 - SSL Functionality
|
||
Bit 26 - Auto IP
|
||
Bits 27 - 31 Reserved"
|
||
::= { npSys 17 }
|
||
|
||
|
||
npSysCardServices3 OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This object is a bitmap showing what services are available
|
||
on the card.
|
||
|
||
Bit 0 - 100T
|
||
Bit 1 - Token Ring 802.5
|
||
Bit 2 - 802.11b
|
||
Bit 3 - 80211.a
|
||
Bit 4 - Bluetooth
|
||
Bits 5 - 11 Reserved
|
||
Bit 12 - EIO. For embedded Jetdirect this bit will be 1.
|
||
Bit 13 - LIO
|
||
Bit 14 - USB
|
||
Bit 15 - Firewire
|
||
Bit 16 - TCP Download
|
||
|
||
Bits 17 - 31 Reserved"
|
||
::= { npSys 22 }
|
||
|
||
|
||
npConnsIP OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Remote IP address of the node currently connected to the card.
|
||
Zero if no connection is active."
|
||
::= { npConns 11 }
|
||
|
||
|
||
npCfgSource OBJECT-TYPE
|
||
SYNTAX INTEGER {manual-one(1),
|
||
bootp-two(2),
|
||
manual-three(3),
|
||
bootp-four(4),
|
||
dhcp(5),
|
||
not-configured(6),
|
||
default-config(7),
|
||
rarp(8),
|
||
read-only(9),
|
||
auto-ip(10)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This object indicates how the device obtained its IP configuration."
|
||
::= { npCfg 1 }
|
||
|
||
|
||
npCfgYiaddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP address assigned to the card from the BOOTP reply
|
||
yiaddr field."
|
||
::= { npCfg 2 }
|
||
|
||
|
||
npCfgSiaddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The IP address of the TFTP server from the BOOTP reply
|
||
siaddr field."
|
||
::= { npCfg 3 }
|
||
|
||
|
||
npCfgLogServer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The IP address of the Syslog Server. If set via BOOTP (Tag: 7 field,
|
||
lg=<ipaddress> ) then SNMP set will fail. If not set via BOOTP then SNMP set
|
||
will succeed. Value saved across warm boot power cycles. BOOTP will always
|
||
overwrite SNMP set values."
|
||
::= { npCfg 5 }
|
||
|
||
|
||
npCfgSyslogFacility OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This specifies the facility identifier used in syslog messages
|
||
generated by the card."
|
||
::= { npCfg 6 }
|
||
|
||
|
||
npCfgAccessState OBJECT-TYPE
|
||
SYNTAX INTEGER {allowed(1),
|
||
not-allowed(2)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "An indication of whether or not the requesting host
|
||
is allowed to connect to the card as dictated by the
|
||
access list."
|
||
::= { npCfg 7 }
|
||
|
||
|
||
npCfgAccessListNum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The number of access list entries."
|
||
::= { npCfg 8 }
|
||
|
||
|
||
npCfgAccessListTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF NpCfgAccessListEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "List of access addresses and masks."
|
||
::= { npCfg 9 }
|
||
|
||
|
||
npCfgAccessListEntry OBJECT-TYPE
|
||
SYNTAX NpCfgAccessListEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Each entry contains an access address and mask."
|
||
::= { npCfgAccessListTable 1 }
|
||
|
||
|
||
npCfgAccessListIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..9)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Index to the configuration access list table."
|
||
::= { npCfgAccessListEntry 1 }
|
||
|
||
|
||
npCfgAccessListAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The Access List Address contains the list of hosts or network
|
||
of hosts that are allowed to connect to the print server over ip.
|
||
When setting this object npCfgAccessListAddrMask should also
|
||
be set in the same varbind packet. NpCfgAccessListAddress
|
||
should always preceed npCfgAccessListAddrMask in the set packet.
|
||
If npCfgAccessListAddrMask is not set, the default value of
|
||
255.255.255.255 will be assigned to npCfgAccessListAddrMask
|
||
for that particular npCfgAccessListAddress entry. Duplicate host
|
||
addresses are possible and, once set, it is not possible to change
|
||
any particular row other than to clear the Access List Table.
|
||
To clear the Access List Table set npCfgAccessListAddress to 0.0.0.0.
|
||
This table has a maximum of 10 rows."
|
||
::= { npCfgAccessListEntry 2 }
|
||
|
||
|
||
npCfgAccessListAddrMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Address mask used to help determine whether or not a given
|
||
IP address is allowed access to the print server. An IP address
|
||
is allowed access if (Addr & AddrMask) == (IP & AddrMask).
|
||
A set of this object may only be done if npCfgAccessListAddress
|
||
preceeds it in the same varbind packet."
|
||
::= { npCfgAccessListEntry 3 }
|
||
|
||
|
||
npCfgSubnetMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The subnet mask associated with the IP address of this card."
|
||
::= { npCfg 12 }
|
||
|
||
|
||
npCfgDefaultGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This variable contains the IP address of the default router for this
|
||
card."
|
||
::= { npCfg 13 }
|
||
|
||
|
||
npCfgDomainName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The print server domain name."
|
||
::= { npCfg 16 }
|
||
|
||
|
||
npCfgIPP OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Below are the different values accepted by this OID.
|
||
|
||
0 - Disable IPP and IPP-S
|
||
1 - Enable IPP and IPP-S
|
||
2 - Enable IPP-S only
|
||
3 - Enable IPP only
|
||
"
|
||
::= { npCfg 18 }
|
||
|
||
|
||
npCfgWINSNameServerIdPri OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Primary name server for NetBIOS over TCP/IP."
|
||
::= { npCfg 22 }
|
||
|
||
|
||
npCfgPasswd1Verify OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Compares string value to passwd1 and returns OK if match,
|
||
GENERAL ERROR if doesn't match."
|
||
::= { npCfg 28 }
|
||
|
||
|
||
npCfgPasswd1 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Password for root or administrator. Get request returns
|
||
either 'SET' or 'NOT_SET'."
|
||
::= { npCfg 29 }
|
||
|
||
|
||
npCfgBanner OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Line Printer Daemon Protocol (LPD) banner page per I/O port.
|
||
(0) = Disabled
|
||
(1) = Enabled
|
||
Enabled by default."
|
||
::= { npCfg 31 }
|
||
|
||
|
||
npCfgLinkType OBJECT-TYPE
|
||
SYNTAX INTEGER {autoNegotiate(1),
|
||
full10T(2),
|
||
half10T(3),
|
||
full100T(4),
|
||
half100T(5),
|
||
auto100T(6),
|
||
full1000T(7)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Network link speed and communication mode."
|
||
::= { npCfg 35 }
|
||
|
||
|
||
npCfgSnmpDefaultReadCmnty OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Controls Default Read Community Name access.
|
||
(0) = Disabled, i.e., default get community names FAIL to access target.
|
||
(1) = Enabled, i.e., default get community names SUCCEED to access target."
|
||
::= { npCfg 40 }
|
||
|
||
|
||
npCfgBonjourServiceName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The name by which all the Jetdirect services will be advertised by
|
||
Multicast Domain Name System (Bonjour). Must set a non empty string"
|
||
::= { npCfg 44 }
|
||
|
||
|
||
npCfgBonjourDomainName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The name used as the 'target name' in the DNS SRV records by
|
||
Multicast Domain Name System (Bonjour)."
|
||
::= { npCfg 46 }
|
||
|
||
|
||
npCfgIPv6DomainName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "IPv6 Domain Name."
|
||
::= { npCfg 49 }
|
||
|
||
|
||
npCfgIPv6ConfigState OBJECT-TYPE
|
||
SYNTAX INTEGER {ipv6-going-down(0),
|
||
ipv6-is-up(1)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "IPv6 stack status event; IPv6 enabled/disabled."
|
||
::= { npCfg 50 }
|
||
|
||
|
||
npCfgIPv6DNSAddr1 OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "IPv6 DNS Address, priority 1."
|
||
::= { npCfg 56 }
|
||
|
||
|
||
npCfgIPv6DNSAddr2 OBJECT-TYPE
|
||
SYNTAX InetAddress
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "IPv6 DNS Address, priority 2."
|
||
::= { npCfg 57 }
|
||
|
||
|
||
npCfgIPConfigPrecedence OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Allows to set uniform rules for parameter overwrite by
|
||
different configuration methods.
|
||
0 - Manual
|
||
1 - TFTP
|
||
2 - DHCPv4/Bootp
|
||
3 - DHCPv6 - only if ipv6 is supported
|
||
3/4 - Default - 4 if ipv6 is supported otherwise 3
|
||
The set string should be 0:1:2:3:4 (or 0:1:2:3 when ipv6 is not supported)
|
||
or any colon separated combination of the 5 (or 4) integral values. The
|
||
string should contain all integral values atleast and atmost once."
|
||
::= { npCfg 59 }
|
||
|
||
|
||
npCfgPortConfig OBJECT-TYPE
|
||
SYNTAX INTEGER {half10T(10),
|
||
full10T(11),
|
||
half100T(12),
|
||
full100T(13),
|
||
full1000T(19)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Network link speed and communication mode."
|
||
::= { npCfg 65 }
|
||
|
||
|
||
npTcpTFTPFileName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The TFTP configuration file name."
|
||
::= { npTcp 9 }
|
||
|
||
|
||
npTcpTFTPServerId OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "TFTP server from which configuration
|
||
information is obtained."
|
||
::= { npTcp 10 }
|
||
|
||
|
||
npTcpSyslogMax OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1000)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Maximum number of syslog packets to be sent
|
||
per minute. 0 = Disabled."
|
||
::= { npTcp 11 }
|
||
|
||
|
||
npTcpAppSyslogPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..8)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Priority below which the syslog messages will
|
||
not be sent.
|
||
Valid priority levels = 0 through 7.
|
||
Disabled = 8."
|
||
::= { npTcp 12 }
|
||
|
||
|
||
npCtlReconfig OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Writing any value to this variable causes the card to
|
||
reconfigure itself by doing the BOOTP/TFTP configuration
|
||
activity."
|
||
::= { npCtl 8 }
|
||
|
||
|
||
npCtlProtocolSet OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This is a 4 byte integer value. The least significant bytes
|
||
represent the protocols on the card. A value of '1' indicates
|
||
a protocol that is enabled. A value of '0' indicates a
|
||
protocol that is disabled.
|
||
The 32-bit protocol enable 'structure' is defined as:
|
||
|
||
bits 31-28: Number of I/O channels/protocols present (NUM_CHAN)
|
||
bits 27-24: Number of I/O channels which may operate concurrently
|
||
(NUM_OP_CHAN)
|
||
bits 23-16: unused, reserved
|
||
bits 15-1: Individual I/O channel/protocol enable bits,
|
||
0 == disable, 1 == enable
|
||
MIO_IOCHAN_NOVELL bit 1
|
||
MIO_IOCHAN_LLC bit 2
|
||
MIO_IOCHAN_TCP bit 3
|
||
MIO_IOCHAN_ATALK bit 4
|
||
MIO_IOCHAN_IPV6 bit 5
|
||
bit 0: When NUM_OP_CHAN == 1, auto-protocol select enable bit,
|
||
0 == disable, 1 == enable (APS_ON)"
|
||
::= { npCtl 9 }
|
||
|
||
|
||
npCtlSNMPEnableDisable OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "0 = SNMP disabled
|
||
1 = SNMP enabled
|
||
If SNMP is enabled, setting this object to 0 will
|
||
disable SNMP on the print server. Once disabled it is not
|
||
possible to enable SNMP via SNMP. When enabled,
|
||
a get request will return 1. SNMP may be enabled
|
||
via a different user interface, such as telnet or
|
||
the print server Embedded Web Server."
|
||
::= { npCtl 14 }
|
||
|
||
|
||
npCtlTelnet OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Configure Telnet service.
|
||
(0) = Telnet disabled
|
||
(1) = Telnet enabled"
|
||
::= { npCtl 19 }
|
||
|
||
|
||
npCtlFTP OBJECT-TYPE
|
||
SYNTAX Integer32 {
|
||
printDisable-downloadDisable(0),
|
||
printEnable-downloadEnable(1),
|
||
printEnable-downloadDisable(2),
|
||
printDisable-downloadEnable(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Configure File Transfer Protocol (FTP) service.
|
||
(0) = Both FTP Print and Download Disabled
|
||
(1) = Both FTP Print and Download Enabled
|
||
(2) = FTP Print Enabled and FTP Download Disabled
|
||
(3) = FTP Print Disabled and FTP Download Enabled
|
||
"
|
||
::= { npCtl 20 }
|
||
|
||
|
||
npCtlSLP OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Configure Service Location Protocol (SLP) service.
|
||
(0) = SLP disabled
|
||
(1) = SLP enabled"
|
||
::= { npCtl 21 }
|
||
|
||
|
||
npCtlLPD OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Configure Line Printer Daemon Protocol (LPD) service.
|
||
(0) = LPD disabled
|
||
(1) = LPD enabled"
|
||
::= { npCtl 22 }
|
||
|
||
|
||
npCtl9100 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Configure TCP port 9100 printing.
|
||
(0) = port 9100 printing disabled
|
||
(1) = port 9100 printing enabled"
|
||
::= { npCtl 24 }
|
||
|
||
|
||
npCtlSysLog OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Configure Syslog service.
|
||
(0) = Syslog service disabled
|
||
(1) = Syslog service enabled
|
||
Enabled by default."
|
||
::= { npCtl 26 }
|
||
|
||
|
||
npCtlSnmpVersionAccess OBJECT-TYPE
|
||
SYNTAX INTEGER {snmpV1RW-snmpV3RW(1),
|
||
snmpV1RO-snmpV3RW(2),
|
||
snmpV1NoAccess-snmpV3RW(3),
|
||
snmpV1RW-snmpV3NoAccess(4),
|
||
snmpV1RO-snmpV3NoAccess(5)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Manages an SNMP version's read and write access to the MIB."
|
||
::= { npCtl 27 }
|
||
|
||
|
||
npCtlSnmpV3InitAccount OBJECT-TYPE
|
||
SYNTAX INTEGER {destroy(0),
|
||
blockInitEncrypt(4)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Used to create initial SNMPv3 account. The following rules apply:
|
||
|
||
0 = clear init account, only if previously 0.
|
||
4 = Block init account, only cold reset will clear or use Web User interface.
|
||
|
||
Setting this object to blocked (4) will block an initial account
|
||
creation until a cold reset."
|
||
::= { npCtl 28 }
|
||
|
||
|
||
npCtlBonjour OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Configure Multicast Domain Name Service.
|
||
(0) = Bonjour disabled
|
||
(1) = Bonjour enabled"
|
||
::= { npCtl 29 }
|
||
|
||
|
||
npCtlNetworkConnectionMode OBJECT-TYPE
|
||
SYNTAX INTEGER {auto-cable-detect(1),
|
||
disable-radio(2),
|
||
disable-wired(3)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This object controls the selection of the active network
|
||
interface used for communication. This is applicable to
|
||
products supporting dual wired and wireless network interfaces"
|
||
::= { npCtl 32 }
|
||
|
||
|
||
npCtlIPSecurityPolicy OBJECT-TYPE
|
||
SYNTAX INTEGER {disable(0),
|
||
enable(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Disable IP Security (IPSec) or Firewall. Only disabling is allowed."
|
||
::= { npCtl 34 }
|
||
|
||
|
||
npCtlWSDiscovery OBJECT-TYPE
|
||
SYNTAX INTEGER {disable(0),
|
||
enable(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Web Services Discovery enable/disable."
|
||
::= { npCtl 36 }
|
||
|
||
|
||
npCtlWSPrint OBJECT-TYPE
|
||
SYNTAX INTEGER {disable(0),
|
||
enable(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Web Services Print enable/disable."
|
||
::= { npCtl 37 }
|
||
|
||
|
||
npCtlLLMNR OBJECT-TYPE
|
||
SYNTAX INTEGER {disable(0),
|
||
enable(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Link-Local Multicast Name Resolution( LLMNR ) enable/disable."
|
||
::= { npCtl 38 }
|
||
|
||
|
||
npCtlFpDot11WirelessState OBJECT-TYPE
|
||
SYNTAX INTEGER {disable(0),
|
||
enable(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Use for enabling and disabling Wireless Radio.
|
||
The following values are defined:
|
||
Disable = 0
|
||
Enable = 1
|
||
Default = 1(Enabled)"
|
||
::= { npCtl 47 }
|
||
|
||
|
||
npCtlAirPrintStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {disable(0),
|
||
enable(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION " Use to Enabled/Disabled AirPrint functionality.
|
||
Disable = 0
|
||
Enable(Default) = 1
|
||
"
|
||
::= { npCtl 68 }
|
||
|
||
|
||
npCtlAllowRFC5746TLS-SSLCompatibilityMode OBJECT-TYPE
|
||
SYNTAX INTEGER {disable(0),
|
||
enable(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION " Added to support RFC-5746.
|
||
This OID can be use to enable/disable legacy SSL renegotiation.
|
||
Disable = 0
|
||
Enable(Default) = 1
|
||
"
|
||
::= { npCtl 70 }
|
||
|
||
|
||
npPortNumPorts OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The number of peripheral interfaces supported by this device."
|
||
::= { npPort 1 }
|
||
|
||
|
||
npDHCPserver OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "IP address of DHCP server that provided this unit with an IP
|
||
address via the DHCP protocol."
|
||
::= { npDhcp 2 }
|
||
|
||
|
||
npDhcpFQDNBehavior OBJECT-TYPE
|
||
SYNTAX INTEGER {present-JD-Behavior(0),
|
||
rFC4702-compliant-Behavior(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This object defines the FQDN behavior in Jetdirect. Set this to
|
||
( 0 ) - Present Jetdirect Behavior
|
||
( 1 ) - RFC 4702 compliant behavior"
|
||
::= { npDhcp 4 }
|
||
|
||
|
||
npWebProxyServerId OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "IP address or hostname of web proxy server."
|
||
::= { npWeb 12 }
|
||
|
||
|
||
npWebProxyServerPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "IP port of web proxy server"
|
||
::= { npWeb 13 }
|
||
|
||
|
||
npWebProxyUserName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Proxy web user identification"
|
||
::= { npWeb 14 }
|
||
|
||
|
||
npWebProxyUserPasswd OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Proxy web user password"
|
||
::= { npWeb 15 }
|
||
|
||
|
||
npWebCheckACLforHTTP OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Configure checking of HTTP web connections against Access Control List.
|
||
(0) = Disable ACL checking
|
||
(1) = Enable ACL checking"
|
||
::= { npWeb 17 }
|
||
|
||
|
||
npSecurityDot11ServerAuthentication OBJECT-TYPE
|
||
SYNTAX INTEGER {eap-md5(1),
|
||
eap-tls(2),
|
||
leap(4),
|
||
peap(8),
|
||
ttls(16)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Server-Based Authentication with the following bitwise values:
|
||
None(0),
|
||
EAP-MD5(1),
|
||
EAP-TLS(2),
|
||
LEAP(4),
|
||
PEAP(8),
|
||
TTLS(16)"
|
||
::= { npSecurity 1 }
|
||
|
||
|
||
npSecurityDot1xEapMd5Identity OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Radius MD5 authentication User Name."
|
||
::= { npSecurity 2 }
|
||
|
||
|
||
npSecurityDot1xTLSAuthServerId OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "TLS authentication Server ID."
|
||
::= { npSecurity 3 }
|
||
|
||
|
||
npSecurityPublicKey OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The public key of a public/private key pair to be
|
||
used by applications to set encrypted values."
|
||
::= { npSecurity 4 }
|
||
|
||
|
||
npSecurityDot11EncryptedDot11NetworkName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION "The encrypted network name (SSID). Use the
|
||
npSecurityPublicKey to encrypt this value.
|
||
Setting this object will cause the card to reconfigure."
|
||
::= { npSecurity 5 }
|
||
|
||
|
||
npSecurityDot11EncryptedDot1xEapMd5Secret OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION "The encrypted dot1xEapMD5Secret authentication password.
|
||
Use the npSecurityPublicKey to encrypt this value.
|
||
Setting this object will cause the card to reconfigure."
|
||
::= { npSecurity 6 }
|
||
|
||
|
||
npSecurityDot11EncryptedWEPKeyTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF NpSecurityDot11EncryptedWEPKeyEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Encrypted interface to the WEP Keys."
|
||
::= { npSecurity 7 }
|
||
|
||
|
||
npSecurityDot11EncryptedWEPKeyEntry OBJECT-TYPE
|
||
SYNTAX NpSecurityDot11EncryptedWEPKeyEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Each row of the table gives a WEP Key"
|
||
::= { npSecurityDot11EncryptedWEPKeyTable 1 }
|
||
|
||
|
||
npSecurityDot11EncryptedWEPKey OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION "The encrypted WEP Key value. Use
|
||
the npSecurityDot11PublicKey to encrypt this value.
|
||
Setting this object will cause the card to reconfigure."
|
||
::= { npSecurityDot11EncryptedWEPKeyEntry 2 }
|
||
|
||
|
||
npSecurityDot11SignalStrength OBJECT-TYPE
|
||
SYNTAX INTEGER {level-1-TBD(1),
|
||
level-2-TBD(2),
|
||
level-3-TBD(3),
|
||
level-4-TBD(4),
|
||
level-5-TBD(5)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "A weighted average over time of the signal strength
|
||
between the access point and the print server in infrastructure
|
||
mode. Not applicable when in ad hoc mode."
|
||
::= { npSecurity 8 }
|
||
|
||
|
||
npSecurityDot11SSIDTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF NpSecurityDot11SSIDEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "List of discovered SSIDs."
|
||
::= { npSecurity 9 }
|
||
|
||
|
||
npSecurityDot11SSIDEntry OBJECT-TYPE
|
||
SYNTAX NpSecurityDot11SSIDEntry
|
||
ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION "Each row of the table gives a discovered SSID value."
|
||
::= { npSecurityDot11SSIDTable 1 }
|
||
|
||
|
||
npSecurityDot11SSID OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "A discovered SSID value."
|
||
::= { npSecurityDot11SSIDEntry 2 }
|
||
|
||
|
||
npSecurityDot11SSIDTableNumEntries OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Displays the number of discovered SSIDs in
|
||
the SSID Table."
|
||
::= { npSecurity 10 }
|
||
|
||
|
||
npSecurityDot11SSLCertLoaded OBJECT-TYPE
|
||
SYNTAX INTEGER {true(1),
|
||
false(2)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Indicates if SSL certificate has been loaded."
|
||
::= { npSecurity 11 }
|
||
|
||
|
||
npSecurityDot11TLSCertLoaded OBJECT-TYPE
|
||
SYNTAX INTEGER {true(1),
|
||
false(2)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Indicates if TLS Trusted CA certificate has been loaded."
|
||
::= { npSecurity 12 }
|
||
|
||
|
||
npSecuritySnmpV3EncryptedUserName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION "The encrypted SNMPv3 User Name.
|
||
Use the npSecurityPublicKey to encrypt this value.
|
||
The new SNMPv3 User Account will be installed after the
|
||
npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase
|
||
and npSecuritySnmpV3PrivKeyPassPharse have been set."
|
||
::= { npSecurity 13 }
|
||
|
||
|
||
npSecuritySnmpV3AuthKeyPassPhrase OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION "The encrypted SNMPv3 Authentication passphrase or key .
|
||
Use the npSecurityPublicKey to encrypt this value.
|
||
The new SNMPv3 User Account will be installed after the
|
||
npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase
|
||
and npSecuritySnmpV3PrivKeyPassPharse have been set.
|
||
|
||
Set npSecuritySnmpV3AuthAlgorithm, npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase
|
||
to the required values before setting this OID.
|
||
"
|
||
::= { npSecurity 14 }
|
||
|
||
|
||
npSecuritySnmpV3PrivKeyPassPharse OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION "The encrypted SNMPv3 Privacy passphrase or key.
|
||
Use the npSecurityPublicKey to encrypt this value.
|
||
The new SNMPv3 User Account will be installed after the
|
||
npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase
|
||
and npSecuritySnmpV3PrivKeyPassPharse have been set.
|
||
|
||
Set npSecuritySnmpV3AuthAlgorithm, npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase
|
||
to the required values before setting this OID.
|
||
"
|
||
::= { npSecurity 15 }
|
||
|
||
|
||
npSecurityDot11BSSID OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The BSSID value (hardware address of the access point)."
|
||
::= { npSecurity 16 }
|
||
|
||
|
||
npSecurityDot1xTunnelAuthBits OBJECT-TYPE
|
||
SYNTAX INTEGER {eap-md5(1),
|
||
eap-mschap(2),
|
||
eap-mschapv2(4),
|
||
mschap(8),
|
||
mschapv2(16),
|
||
eap-gtc(32)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The Dot1x Tunnel Authentication Bits. Bitwise field
|
||
with the followings bits:
|
||
|
||
Default All bits cleared
|
||
EAP MD5 1
|
||
EAP MSCHAP 2
|
||
EAP MSCHAPv2 4
|
||
MSCHAP 8
|
||
MSCHAPv2 16
|
||
EAP GTC 32"
|
||
::= { npSecurity 17 }
|
||
|
||
|
||
npSecurityDot1xIdentityCleartext OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The Dot1x Identity in cleartext."
|
||
::= { npSecurity 18 }
|
||
|
||
|
||
npSecurityDot11ExactMatchServerId OBJECT-TYPE
|
||
SYNTAX INTEGER {true(1),
|
||
false(2)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Indicates if an exact match is required on the EAP Server ID."
|
||
::= { npSecurity 19 }
|
||
|
||
|
||
npSecurityDot11EncryptionStrength OBJECT-TYPE
|
||
SYNTAX INTEGER {low(1),
|
||
medium(2),
|
||
high(3)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Indicates the EAP encrytpion strength."
|
||
::= { npSecurity 20 }
|
||
|
||
|
||
npSecurityCertBuff OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "A 512 byte buffer of the print server certificate as indexed by
|
||
npSecurityCertBuffIndex."
|
||
::= { npSecurity 21 }
|
||
|
||
|
||
npSecurityCertBuffIndex OBJECT-TYPE
|
||
SYNTAX INTEGER {block1(1),
|
||
block2(2),
|
||
block3(3),
|
||
block4(4),
|
||
block5(5),
|
||
block6(6)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Indicates the index of the 512 byte block of the print server
|
||
certificate to load into npSecurityCertBuff."
|
||
::= { npSecurity 22 }
|
||
|
||
|
||
npSecuritySslRedirection OBJECT-TYPE
|
||
SYNTAX INTEGER {redirectionEnabled(1),
|
||
redirectionDisabled(2)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Setting this object causes the SSL redirection connection
|
||
to be enabled or disabled."
|
||
::= { npSecurity 23 }
|
||
|
||
|
||
npSecurityReset OBJECT-TYPE
|
||
SYNTAX INTEGER {set(0),
|
||
reset(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Setting this object causes security object to reset bact to the defaults."
|
||
::= { npSecurity 24 }
|
||
|
||
|
||
npSecurityWebSpiEnable OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This object enables/disables the Embedded Web Simple Printer Install feature."
|
||
::= { npSecurity 25 }
|
||
|
||
|
||
npSecurityDot11WEPStrength OBJECT-TYPE
|
||
SYNTAX INTEGER {not-set(1),
|
||
strenth-40-bit(2),
|
||
strenth-104-bit(3)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Indicates the encryption strength of the WEP keys."
|
||
::= { npSecurity 26 }
|
||
|
||
|
||
npSecurityServicesSupported OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "BITWISE indication of the 802.11 security services this device supports.
|
||
The following bits are defined:
|
||
|
||
MD5 (0)
|
||
TLS (1)
|
||
TTLS (2)
|
||
LEAP (3)
|
||
PEAP (4)
|
||
Reserved (5 - 15)
|
||
WEP (16)
|
||
WPA (17)
|
||
AES (18)
|
||
WPA2 (19)
|
||
AUTO_FOR_WEP_SUPPORTED (20)
|
||
AUTO_FOR_WPA_SUPPORTED (21)
|
||
AUTO_FOR_ENCRYPTION_SUPPORTED (22)
|
||
Reserved (23 - 31)"
|
||
::= { npSecurity 27 }
|
||
|
||
|
||
npSecurityDot11Encryption OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "802.11 encryption method currently enabled.
|
||
The following values are defined:
|
||
|
||
NONE (0x00)
|
||
SSN/WEP (0x01)
|
||
TKIP (0x02)
|
||
AES (0x03)
|
||
AUTO (0x04)
|
||
Reserved (5 - 31)
|
||
|
||
It is advised not to use dot11PrivacyInvoked OID anymore, instead use npSecurityDot11Encryption.
|
||
Since Jetdirect updates the same variable when the set happens through any of the two OIDs and
|
||
npSecurityDot11Encryption is more versatile, it is recommended to use this OID.
|
||
"
|
||
::= { npSecurity 28 }
|
||
|
||
|
||
npSecurityDot11MulticastCipher OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "BITWISE indication of the multicast cipher method currently enabled.
|
||
At minimum, one bit must be set.
|
||
The following bits are defined:
|
||
|
||
WEP (0)
|
||
WPA (1)
|
||
Reserved (2 - 31)"
|
||
::= { npSecurity 29 }
|
||
|
||
|
||
npSecurityDot11BeaconTableNumEntries OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Displays the number of discovered SSIDs in the DOT11 Beacon Table."
|
||
::= { npSecurity 34 }
|
||
|
||
|
||
npSecurityDot11OpenSSIDEnabled OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Indicates if the Open SSID is enabled (Spirit-only)."
|
||
::= { npSecurity 35 }
|
||
|
||
|
||
npSecurityDot11EncryptedWPAConfigPSKPassPhrase OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS current
|
||
DESCRIPTION "The encrypted WPA Config PSK PassPhrase. Use the
|
||
npSecurityPublicKey to encrypt this value"
|
||
::= { npSecurity 36 }
|
||
|
||
|
||
npSecurityDot11DataRate OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Current wireless network data rate"
|
||
::= { npSecurity 37 }
|
||
|
||
|
||
npSecurityDot11ScanComplete OBJECT-TYPE
|
||
SYNTAX INTEGER {true(1),
|
||
false(2)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Used to control scan for SSIDs in the wireless network.
|
||
Set to false to initiate a scan. A value of true indicates
|
||
the completion of the scan"
|
||
::= { npSecurity 38 }
|
||
|
||
|
||
npSecurityDot11RoamThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER {no-signal(1),
|
||
very-weak-signal(2),
|
||
weak-signal(3)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Used to control roaming by the wireless radio. The radio on
|
||
the print server will roam or try to find an access point with
|
||
a stronger signal once the signal strength from the associated
|
||
access point reaches the specified roam threshold level."
|
||
::= { npSecurity 39 }
|
||
|
||
|
||
npSecuritySslEncryptionStrength OBJECT-TYPE
|
||
SYNTAX INTEGER {low(1),
|
||
medium(2),
|
||
high(3)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "The SSL Encryption Strength."
|
||
::= { npSecurity 40 }
|
||
|
||
|
||
npSecurityDot11InstantVerification OBJECT-TYPE
|
||
SYNTAX INTEGER {disable(0),
|
||
enable(1)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Enable and disable wireless instant verification.
|
||
(0) = Disable
|
||
(1) = Enable"
|
||
::= { npSecurity 41 }
|
||
|
||
|
||
npSecurityDot11DynamicEncryption OBJECT-TYPE
|
||
SYNTAX INTEGER {nONE(0),
|
||
bASIC(1),
|
||
wPA(2),
|
||
wPA2(3),
|
||
aUTO(4)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "WPA mode.
|
||
(0x00) = NONE
|
||
(0x01) = BASIC
|
||
(0x02) = WPA
|
||
(0x03) = WPA2
|
||
(0x04) = AUTO"
|
||
::= { npSecurity 42 }
|
||
|
||
|
||
npSecurityDot11LinkAuthentication OBJECT-TYPE
|
||
SYNTAX INTEGER {open(1),
|
||
shared-key(2),
|
||
leap(128),
|
||
auto(143)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "DOT11 Link Authentication modes.
|
||
(1) = OPEN
|
||
(2) = SHARED-KEY
|
||
(128) = LEAP
|
||
(143) = AUTO
|
||
|
||
We can set the Link Authentication using the object dot11AuthenticationAlgorithmsEnable ( OID: 1.2.840.10036.1.2.1.3.x )
|
||
Since the dot11AuthenticationAlgorithsmEnable object does not supports setting of AUTO option, we provide this object.
|
||
|
||
Through this OID you can set to any one of the above options.
|
||
Whereas using the dot11AuthenticationAlgorithmsEnable object we can set either OPEN OR SHARED mode only."
|
||
::= { npSecurity 43 }
|
||
|
||
|
||
npSecuritySnmpV3AuthAlgorithm OBJECT-TYPE
|
||
SYNTAX INTEGER {md5(2),
|
||
sha-1(3)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Indicates the Authentication Algorithm used.
|
||
It can have the value MD5 or SHA-1.
|
||
This key will have a default value set to MD5.
|
||
The following values are defined:
|
||
MD5 2 (Default)
|
||
SHA-1 3
|
||
"
|
||
::= { npSecurity 44 }
|
||
|
||
|
||
npSecuritySnmpV3PrivAlgorithm OBJECT-TYPE
|
||
SYNTAX INTEGER {des(2),
|
||
aes-128(3)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Indicates the Privacy Algorithm used.
|
||
It can have the value DES or AES-128.
|
||
This key will have a default value set to DES.
|
||
The following values are defined:
|
||
DES 2 (Default)
|
||
AES-128 3
|
||
"
|
||
::= { npSecurity 45 }
|
||
|
||
|
||
npSecurityDot1xFailSafe OBJECT-TYPE
|
||
SYNTAX INTEGER {enable(1),
|
||
disable(0)}
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "After configuring 802.1x on the printer and switching it over to a secured network, if authentication is
|
||
successful printer retains connectivity and if it fails it loses connectivity.
|
||
In case of authentication failure, it does not acquire connectivity even when switched over to an unsecured network.
|
||
802.1x failsafe is a feature which allows printer to retain connectivity in a unsecured network even if authentication fails.
|
||
Setting this OID to 1 enables this feature and setting to 0 disables this feature.
|
||
|
||
Connect anyway (802.1x Fail-Safe) ( 1 )
|
||
Block network (secure failure) ( 0 )
|
||
"
|
||
::= { npSecurity 57 }
|
||
|
||
|
||
gdStatusBytes OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The number of valid bytes in the gdStatusEntry
|
||
array."
|
||
::= { generalDeviceStatus 1 }
|
||
|
||
|
||
gdStatusDisplay OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The string diplayed on the peripheral front panel.
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this is always a zero length string."
|
||
::= { generalDeviceStatus 3 }
|
||
|
||
|
||
gdStatusId OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "A formatted string of NVT ASCII
|
||
charactersdescribing this peripheral."
|
||
::= { generalDeviceStatus 7 }
|
||
|
||
|
||
gdStatusJobTimeout OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-write
|
||
STATUS obsolete
|
||
::= { generalDeviceStatus 10 }
|
||
|
||
|
||
gdPasswords OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This object is used as a 256 byte NVRAM area for JetAdmin. It
|
||
is completely managed by JetAdmin. Initially it is initialized
|
||
to all zeros. A coldboot will re-initialize to all zeros."
|
||
::= { generalDeviceStatus 13 }
|
||
|
||
|
||
pmlTrapEnable OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This OID is used to enable individual peripheral trappable objects through the print server."
|
||
::= { netPMLtrap 1 }
|
||
|
||
|
||
pmlTrapDisable OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "This OID is used to disable individual peripheral trappable objects through the print server."
|
||
::= { netPMLtrap 2 }
|
||
|
||
|
||
npNpiPaeClass OBJECT-TYPE
|
||
SYNTAX INTEGER {printer(1),
|
||
plotter(2),
|
||
xStation(3)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The class assigned to the peripheral onto which
|
||
this card is plugged."
|
||
::= { npNpiPeripheralAttributeEntry 2 }
|
||
|
||
|
||
npNpiPaeIdentification OBJECT-TYPE
|
||
SYNTAX INTEGER {laserjet-IIISI(1),
|
||
laserjet-4SI(5)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The Identification number of the peripheral. These values are
|
||
defined in the MIO spec. DesignJet, PaintJet XL300, and
|
||
DesignJet/600 peripherals will identify themselves as
|
||
LaserJet-IIIsi."
|
||
::= { npNpiPeripheralAttributeEntry 3 }
|
||
|
||
|
||
npNpiCaeClass OBJECT-TYPE
|
||
SYNTAX INTEGER {rs-232(1),
|
||
centronics(2),
|
||
csma-cd-network(3),
|
||
token-ring-network(4),
|
||
scsi(5),
|
||
hpib(6),
|
||
localtalk(7),
|
||
hpna(8),
|
||
usb(9),
|
||
firewire(10),
|
||
bluetooth(11),
|
||
ieee802-11b(12)}
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "The class of this network peripheral card."
|
||
::= { npNpiCardAttributeEntry 2 }
|
||
|
||
|
||
gdStatusLineState OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This describes the line state of the peripheral.
|
||
When non-zero, the peripheral is off-line. When
|
||
zero the peripheral is on-line."
|
||
::= { gdStatusEntry 1 }
|
||
|
||
|
||
gdStatusPaperState OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This describes the state of the paper on the peripheral.
|
||
When non-zero, the peripheral has a paper problem. When
|
||
zero, the peripheral does not have a paper problem."
|
||
::= { gdStatusEntry 2 }
|
||
|
||
|
||
gdStatusInterventionState OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This describes the intervention state of the
|
||
peripheral. When non-zero, the peripheral requires
|
||
human intervention to continue working. When
|
||
zero, it requires no assistance."
|
||
::= { gdStatusEntry 3 }
|
||
|
||
|
||
gdStatusPeripheralError OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This is the error code from the peripheral."
|
||
::= { gdStatusEntry 6 }
|
||
|
||
|
||
gdStatusPaperOut OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral is out of paper.
|
||
off (0),
|
||
paper-out-or-paper-mount (1),
|
||
manual-paper-feed-needed (2)
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 8 }
|
||
|
||
|
||
gdStatusPaperJam OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral has a paper jam.
|
||
off (0),
|
||
paper-jam(1)
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 9 }
|
||
|
||
|
||
gdStatusTonerLow OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral has a low toner condition.
|
||
off (0),
|
||
toner-low (1),
|
||
no-toner-cartridge (2)
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 10 }
|
||
|
||
|
||
gdStatusPagePunt OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral did not receive data fast
|
||
enough to keep up with the print engine when generating a page.
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 11 }
|
||
|
||
|
||
gdStatusMemoryOut OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral did not have enough memory
|
||
to render an image on a page.
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 12 }
|
||
|
||
|
||
gdStatusIoActive OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral is processing data from
|
||
this I/O interface card. For some peripherals, such as the
|
||
HP LaserJet IIISi printer or HP DesignJet plotter,
|
||
this value is always a zero (0).
|
||
|
||
For X.20.06 firmware and later firmware releases, this object is
|
||
not relevant. In order not to break legacy applications which call this
|
||
object in multi-varbind requests, this value is always zero (0)."
|
||
::= { gdStatusEntry 13 }
|
||
|
||
|
||
gdStatusBusy OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral is busy processing
|
||
print/plot data.
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 14 }
|
||
|
||
|
||
gdStatusWait OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral is waiting for print/plot
|
||
data to process.
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 15 }
|
||
|
||
|
||
gdStatusInitialize OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral is initializing or
|
||
warming up.
|
||
off (0),
|
||
initializing (1),
|
||
warm-up(2)
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 16 }
|
||
|
||
|
||
gdStatusDoorOpen OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral cover or door is open.
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 17 }
|
||
|
||
|
||
gdStatusPrinting OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral is printing or otherwise
|
||
marking or moving paper.
|
||
off (0),
|
||
ordinary-page (1),
|
||
test-fonts-config-or-start-page (2)
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 18 }
|
||
|
||
|
||
gdStatusPaperOutput OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "This indicates that the peripheral has a paper output problem
|
||
such as the output storage bin being full.
|
||
off (0),
|
||
output-storage-full (1)
|
||
For some peripherals, such as the HP LaserJet IIISi printer
|
||
or HP DesignJet plotter, this value is always a zero (0)."
|
||
::= { gdStatusEntry 19 }
|
||
|
||
|
||
photo-access-card-error OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePhotoCardAccessNoError(0),
|
||
ePhotoCardSmartMediaUpsideDown(1),
|
||
ePhotoCardMediaNotFullyInserted(2),
|
||
ePhotoCardMoreThenOneInSlots(3),
|
||
ePhotoCardReadError(4),
|
||
ePhotoCardRemovedWhileReading(5),
|
||
ePhotoCardBadFileWhilePrinting(6),
|
||
ePhotoCardNotInSlot(7),
|
||
ePhotoCardContainsNoPhotos(8),
|
||
ePhotoCardWriteError(9),
|
||
ePhotoCardRemovedWhileWriting(10),
|
||
ePhotoCardUnknownError(999)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Specifies the error reason for most recent unsucessful photo
|
||
card access.
|
||
Additional information:
|
||
Specifies the error reason for most recent unsucessful photo
|
||
card access."
|
||
::= { photo-job 2 }
|
||
|
||
|
||
photo-default-num-copies OBJECT-TYPE
|
||
SYNTAX INTEGER(1..99)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the default number of copies to be printed
|
||
during photo application print jobs. This value is saved over a
|
||
power cycle.
|
||
Additional information:
|
||
Reads or writes the default number of copies to be
|
||
printed during photo application print jobs. This value is
|
||
saved over a power cycle."
|
||
::= { settings-photo-job 1 }
|
||
|
||
|
||
photo-job-num-copies OBJECT-TYPE
|
||
SYNTAX INTEGER(1..99)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the number of copies to be printed during the
|
||
next photo application print job. This value is not saved over
|
||
power cycles.
|
||
Additional information:
|
||
Reads or writes the number of copies to be printed
|
||
during the next photo application print job. This value is
|
||
not saved over a power cycle."
|
||
::= { settings-photo-job 2 }
|
||
|
||
|
||
photo-job-media-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eISOandJISA4(26),
|
||
ePhoto4x6(76)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the default media size to be used during the
|
||
next photo application print job. This value is not saved over
|
||
power cycles.
|
||
Additional information:
|
||
Reads or writes the default media size to be
|
||
used during the next photo application print job. This
|
||
value is not saved over a power cycle."
|
||
::= { settings-photo-job 4 }
|
||
|
||
|
||
photo-job-media-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the media type to be used on the next photo
|
||
application print job. This value is not saved over power
|
||
cycles.
|
||
Additional information:
|
||
Reads or writes the media type to be used on the next
|
||
photo application print job. This value is not saved over a
|
||
power cycle."
|
||
::= { settings-photo-job 6 }
|
||
|
||
|
||
photo-image-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eThumbnail(1),
|
||
eWallet(2),
|
||
e3halfx5in(3),
|
||
e3x4in(4),
|
||
e4x6in(5),
|
||
e5x7in(6),
|
||
e6x8in(7),
|
||
e8x10in(8),
|
||
e6x8cm(9),
|
||
e7x10cm(10),
|
||
e9x13cm(11),
|
||
e10x15cm(12),
|
||
e13x18cm(13),
|
||
e15x21cm(14),
|
||
e18x24cm(15),
|
||
e20x25cm(16),
|
||
eFullPage(17),
|
||
ePanoramic(18)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the default image size to be used during photo
|
||
application print jobs. This value is saved over power cycles.
|
||
Additional information:
|
||
Reads or writes the default image size to be
|
||
used during photo application print jobs. This value is
|
||
saved over a power cycle. Valid image sizes are determined
|
||
by the PHOTO-IMAGE-SIZE-SET pml object."
|
||
::= { settings-photo-job 7 }
|
||
|
||
|
||
photo-job-image-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eThumbnail(1),
|
||
eWallet(2),
|
||
e3halfx5in(3),
|
||
e3x4in(4),
|
||
e4x6in(5),
|
||
e5x7in(6),
|
||
e6x8in(7),
|
||
e8x10in(8),
|
||
e6x8cm(9),
|
||
e7x10cm(10),
|
||
e9x13cm(11),
|
||
e10x15cm(12),
|
||
e13x18cm(13),
|
||
e15x21cm(14),
|
||
e18x24cm(15),
|
||
e20x25cm(16),
|
||
eFullPage(17),
|
||
ePanoramic(18)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the image size to be used during the next photo
|
||
application print job. This value is not saved over power
|
||
cycles.
|
||
Additional information:
|
||
Reads or writes the image size to be used during
|
||
the next photo application print job. This value is not
|
||
saved over a power cycle. Valid image sizes are determined
|
||
by the PHOTO-IMAGE-SIZE-SET pml object."
|
||
::= { settings-photo-job 8 }
|
||
|
||
|
||
photo-select-images OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the list of images to print during the next
|
||
photo application print job. Each image number or number range
|
||
must be separated by a comma. The image number corresponds to
|
||
the location of the file on the image card. For example, if
|
||
there are 10 images on the photo card, then you could select
|
||
'1-10' or '1,2,3,4,5' or '1,2,3,4-9'. The same image number can
|
||
also appear multiple times in the list. i.e.
|
||
'1,2,2,2,3,3,4,4,5'. This value is not saved over power cycles
|
||
and only applies to the next job.
|
||
Additional information:
|
||
Reads or writes the list of images to print
|
||
during the next photo application print job. Each image
|
||
number or number range must be separated by a comma. The
|
||
image number corresponds to the location of the file on
|
||
the image card. For example, if there are 10 images on
|
||
the photo card, then you could select 1-10 or 1,2,3,4,5 or
|
||
1,2,3,4-9. The same image number can also appear multiple
|
||
times in the list. i.e. 1,2,2,2,3,3,4,4,5. This value is
|
||
not saved over a power cycle, and only applies to the next
|
||
job."
|
||
::= { settings-photo-job 9 }
|
||
|
||
|
||
photo-images-on-card OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Reads the number of printable photo images found on the
|
||
inserted memory card. If 0, then no images were found, or the
|
||
card was not properly inserted.
|
||
Additional information:
|
||
Reads the number of printable photo images found
|
||
on the inserted memory card. If 0, then no images were
|
||
found, or the card was not properly inserted."
|
||
::= { settings-photo-job 10 }
|
||
|
||
|
||
photo-job-source OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePhotoPrintProofSheet(1),
|
||
ePhotoScanProofSheet(2),
|
||
ePhotoPrintColorJob(3),
|
||
ePhotoPrintMonochromeJob(4),
|
||
ePhotoPrintIndexPrint(5)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "Controls initiating photo application features.
|
||
Additional information:
|
||
Controls initiating photo application features."
|
||
::= { settings-photo-job 11 }
|
||
|
||
|
||
photo-color-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the page count for color pages printed by the
|
||
photo application. This value is saved over power cycles.
|
||
Additional information:
|
||
Reads or writes the page count for color pages
|
||
printed by the photo application. This value is saved over
|
||
a power cycle."
|
||
::= { settings-photo-job 12 }
|
||
|
||
|
||
photo-mono-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the page count for monochrome pages printed by
|
||
the photo application. This value is saved over power cycles.
|
||
Additional information:
|
||
Reads or writes the page count for monochrome pages
|
||
printed by the photo application. This value is saved over
|
||
a power cycle."
|
||
::= { settings-photo-job 13 }
|
||
|
||
|
||
photo-image-size-set OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eImageSizeSetInch1(1),
|
||
eImageSizeSetInch2(2),
|
||
eImageSizeSetCentimeter1(3),
|
||
eImageSizeSetCentimeter2(4),
|
||
eImageSizeSetCentimeter3(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This is only writable in service mode. This object changes the
|
||
set of valid image sizes for the device. The image sizes groups
|
||
are as follows:
|
||
eImageSizeSetInch1: Wallet, 3x4in, 3 1/2 x 5in, 4x6in,
|
||
5x7in, 8x10in, full page
|
||
eImageSizeSetInch2: Wallet, 3 1/2 x 5in, 4x6in, 5x7in,
|
||
6x8in, 8x10in, full page
|
||
eImageSizeSetCentimeter1: 6x8cm, 7x10cm, 9x13cm, 10x15cm,
|
||
13x18cm, 15x21cm, 20x25cm, full page
|
||
eImageSizeSetCentimeter2: 7x10cm, 9x13cm, 10x15cm, 13x18cm,
|
||
20x25cm, full page
|
||
eImageSizeSetCentimeter3: 6x8cm, 9x13cm, 10x15cm, 13x18cm,
|
||
15x21cm, 18x24cm, 20x25cm, full page .
|
||
Additional information:
|
||
This is only writable in service mode. This object
|
||
changes the set of valid image sizes for the device. The image
|
||
sizes groups are as follows:
|
||
eImageSizeSetInch1: Thumbnail, Wallet, 3x4in, 3 1/2 x 5in, 4x6in,
|
||
5x7in, 8x10in, full page, panorama
|
||
eImageSizeSetInch2: Thumbnail, Wallet, 3 1/2 x 5in, 4x6in, 5x7in,
|
||
6x8in, 8x10in, full page, panorama
|
||
eImageSizeSetCentimeter1: Thumbnail, 6x8cm, 7x10cm, 9x13cm, 10x15cm,
|
||
13x18cm, 15x21cm, 20x25cm, full page, panorama
|
||
eImageSizeSetCentimeter2: Thumbnail, 7x10cm, 9x13cm, 10x15cm, 13x18cm,
|
||
20x25cm, full page, panorama
|
||
eImageSizeSetCentimeter3: Thumbnail, 6x8cm, 9x13cm, 10x15cm, 13x18cm,
|
||
15x21cm, 18x24cm, 20x25cm, full page, panorama"
|
||
::= { settings-photo-job 15 }
|
||
|
||
|
||
photo-clear-counts OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eClearPageCounts(1),
|
||
eClearInsertCounts(2),
|
||
eClearAllCounts(3)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "writing this object causes the page counts, insert counts, or
|
||
all photo counts to be cleared and reset to 0.
|
||
Additional information:
|
||
writing this object causes the page counts, insert counts, or all photo counts
|
||
to be cleared and reset to 0."
|
||
::= { settings-photo-job 18 }
|
||
|
||
|
||
photo-compact-flash-insert-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the count for the number of times a compact
|
||
flash memory card has been inserted in the device. This value
|
||
is saved over a power cycle.
|
||
Additional information:
|
||
reads or writes the count for the number of times a compact flash memory card
|
||
has been inserted in the device. This value is saved over a power cycle."
|
||
::= { settings-photo-job 19 }
|
||
|
||
|
||
photo-memory-stick-insert-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the count for the number of times a memory
|
||
stick memory card has been inserted in the device. This value
|
||
is saved over a power cycle.
|
||
Additional information:
|
||
reads or writes the count for the number of times a memory stick memory card
|
||
has been inserted in the device. This value is saved over a power cycle."
|
||
::= { settings-photo-job 20 }
|
||
|
||
|
||
photo-memory-stick-pro-insert-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the count for the number of times a memory
|
||
stick pro memory card has been inserted in the device. This
|
||
value is saved over a power cycle.
|
||
Additional information:
|
||
reads or writes the count for the number of times a memory stick pro memory card
|
||
has been inserted in the device. This value is saved over a power cycle."
|
||
::= { settings-photo-job 21 }
|
||
|
||
|
||
photo-smart-media-insert-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the count for the number of times a smart media
|
||
memory card has been inserted in the device. This value is
|
||
saved over a power cycle.
|
||
Additional information:
|
||
reads or writes the count for the number of times a compact flash memory card
|
||
has been inserted in the device. This value is saved over a power cycle."
|
||
::= { settings-photo-job 22 }
|
||
|
||
|
||
photo-secure-digital-insert-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the count for the number of times a secure
|
||
digital memory card has been inserted in the device. This value
|
||
is saved over a power cycle.
|
||
Additional information:
|
||
reads or writes the count for the number of times a compact flash memory card
|
||
has been inserted in the device. This value is saved over a power cycle."
|
||
::= { settings-photo-job 23 }
|
||
|
||
|
||
photo-mmc-insert-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the count for the number of times a
|
||
MultiMediaCard memory card has been inserted in the device.
|
||
This value is saved over a power cycle.
|
||
Additional information:
|
||
reads or writes the count for the number of times a MultiMediaCard memory card
|
||
has been inserted in the device. This value is saved over a power cycle."
|
||
::= { settings-photo-job 24 }
|
||
|
||
|
||
photo-xd-insert-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Reads or writes the count for the number of times an xD-Picture
|
||
memory card has been inserted in the device. This value is
|
||
saved over a power cycle.
|
||
Additional information:
|
||
reads or writes the count for the number of times an xD-Picture memory card
|
||
has been inserted in the device. This value is saved over a power cycle."
|
||
::= { settings-photo-job 25 }
|
||
|
||
|
||
pe-test-photocard-manufacturing-errors OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Error status of the photocard manufacturing test.
|
||
Additional information:
|
||
Error status of the photocard manufacturing test."
|
||
::= { print-engine-test 90 }
|
||
|
||
|
||
pe-test-photocard-manufacturing-test-config OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "Configures the device for photocard manufacturing test mode.
|
||
Additional information:
|
||
Configures the device for photocard manufacturing test mode."
|
||
::= { print-engine-test 91 }
|
||
|
||
|
||
pe-test-photocard-data-input OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "This object sets the value of the test string to be written to
|
||
the photocard.
|
||
Additional information:
|
||
This object sets the value of the test string to be
|
||
written to the photocard ."
|
||
::= { print-engine-test 95 }
|
||
|
||
|
||
pe-test-photocard-dir-input OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "This object creates or opens a directory with the string name
|
||
on a photocard.
|
||
Additional information:
|
||
This object creates or opens a directory with the string
|
||
name on a photocard."
|
||
::= { print-engine-test 96 }
|
||
|
||
|
||
pe-test-photocard-file-input OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "This object creates or opens a file with the string name on a
|
||
photocard.
|
||
Additional information:
|
||
This object creates or opens a file with the string name on a
|
||
photocard."
|
||
::= { print-engine-test 97 }
|
||
|
||
|
||
energy-star OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the Energy Star sleep value. If the value
|
||
is greater than zero, then the device will go into energy
|
||
saving sleep mode after the print engine has been idle for the
|
||
number of seconds specified by this object. A value of zero
|
||
means Energy Star is disabled and the device will not go to
|
||
sleep based on print engine idle time. The value must be
|
||
non-negative.
|
||
Additional information:
|
||
The product will always be in
|
||
sleep mode when not processing data. This object will
|
||
always return a value of 1."
|
||
::= { settings-system 1 }
|
||
|
||
|
||
sleep-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eFalse(1),
|
||
eTrue(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns eTrue if the device is in energy saving sleep mode,
|
||
otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes
|
||
the device to wake up, if it is in sleep mode. Setting
|
||
SLEEP-MODE to eTrue causes the device to go into sleep mode.
|
||
Additional information:
|
||
The product will always be in
|
||
sleep mode except when either processing a print job or
|
||
in an error state."
|
||
::= { settings-system 2 }
|
||
|
||
|
||
service-password OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "When set to the password value, other service related objects
|
||
become 'visible' (i.e readable) or become writable. When
|
||
written with any other value, the service related objects
|
||
become 'hidden' (i.e. are no longer readable) or are not longer
|
||
writable. The objects that can be effected by the
|
||
SERVICE-PASSWORD object include: SERIAL-NUMBER and
|
||
TOTAL-ENGINE-PAGE-COUNT. The password value, and the list of
|
||
objects effected by the SERVICE-PASSWORD being set to the
|
||
correct value, should be documented in the device POS.
|
||
Additional information:
|
||
The objects that can be effected by the SERVICE-
|
||
PASSWORD are: SCANNER-JAM-PAGE-COUNT, SCANNER-ADF-PAGE
|
||
-COUNT, SCAN-ADF-PAGE-COUNT, SCANNER-RETRIEVE-SCANLINE,
|
||
SCANNER-MOTOR-CONTROL, COPIER-ADF-PAGE-COUNT, COPIER-
|
||
PRINT-PAGE-COUNT, TOTAL-ENGINE-PAGE-COUNT, PRINT-ENGINE-
|
||
JAM-COUNT, PRINT-ENGINE-MISPICK-COUNT, CLEAR-NVRAM"
|
||
::= { settings-system 9 }
|
||
|
||
|
||
fuser-pressure-release OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisengage(1)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "This object is used to disengage the pressure on the fuser to
|
||
prevent roller marks on the fuser, which can occur when the
|
||
pressure is engaged for long periods of time.
|
||
Additional information:
|
||
This object is used to disengage the pressure on the
|
||
fuser to prevent roller marks on the fuser, which can occur when
|
||
the pressure is engaged for long periods of time."
|
||
::= { settings-system 53 }
|
||
|
||
|
||
device-configure-generic-language-prompt OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object is used to determine whether to prompt the user to
|
||
enter the appropriate language.
|
||
Additional information:
|
||
This object is used to determine whether to
|
||
prompt the user to enter the appropriate language
|
||
at boot."
|
||
::= { device-configure 10 }
|
||
|
||
|
||
device-configure-generic-country-prompt OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION " This object is used to determine whether to prompt the user to
|
||
enter the appropriate country at boot.
|
||
Additional information:
|
||
This object is used to determine whether to
|
||
prompt the user to enter the appropriate country
|
||
at boot."
|
||
::= { device-configure 11 }
|
||
|
||
|
||
device-configure-generic-country OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eKorea(4),
|
||
eIndonesia(5),
|
||
eChina(6),
|
||
eTaiwan(7),
|
||
ePhilippines(8),
|
||
eThailand(9),
|
||
eSriLanka(10),
|
||
eBrazil(12),
|
||
eCanada(13),
|
||
eMexico(14),
|
||
eUnitedStates(15),
|
||
eArgentina(16),
|
||
eChile(17),
|
||
eNewZealand(19),
|
||
eIsrael(21),
|
||
eUAE(22),
|
||
eAustralia(23),
|
||
eIndia(25),
|
||
ePakistan(26),
|
||
eMalaysia(27),
|
||
eHongKong(29),
|
||
eSingapore(30),
|
||
eUnitedKingdom(31),
|
||
eAustria(34),
|
||
eNetherlands(35),
|
||
eGermany(39),
|
||
eDenmark(40),
|
||
eSweden(41),
|
||
eSouthAfrica(42),
|
||
eNorway(43),
|
||
eIreland(44),
|
||
eBelgium(45),
|
||
eFinland(46),
|
||
eFrance(47),
|
||
eTurkey(48),
|
||
eGreece(49),
|
||
ePortugal(50),
|
||
eItaly(51),
|
||
eSpain(55),
|
||
ePoland(56),
|
||
eBulgaria(57),
|
||
eCroatia(58),
|
||
eRomania(59),
|
||
eSlovakRepublic(60),
|
||
eCzechRepublic(61),
|
||
eHungary(62),
|
||
eRussia(64),
|
||
ePeru(70),
|
||
eJordan(78),
|
||
eLebanon(79),
|
||
eSwitzerland(82),
|
||
eVietnam(83),
|
||
eLuxemberg(85),
|
||
eNorthAfrica(86),
|
||
eBelarus(66),
|
||
eBrunei(33),
|
||
eCambodia(94),
|
||
eCyprus(95),
|
||
eEgypt(67),
|
||
eEstonia(54),
|
||
eIceland(96),
|
||
eLatvia(53),
|
||
eLiechtentstein(98),
|
||
eLithuania(52),
|
||
eMalta(99),
|
||
eMorocco(65),
|
||
eSaudiArabia(28),
|
||
eTunisia(32),
|
||
eUkraine(63)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Set the location configuration for the device. This affects
|
||
parameters that vary per region like the default paper size,
|
||
symbol set, supply reorder URL, and fax parameters if
|
||
applicable."
|
||
::= { device-configure 16 }
|
||
|
||
|
||
device-configure-secure-nvram-items OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object is used to configure product settings that are
|
||
stored in secure area of nvram. The object consists of a 16-bit
|
||
variable in secure nvram. Bits 15-8 are product specific. Bits
|
||
7-0 are system specific.
|
||
Additional information:
|
||
This object is used to configure product settings that are
|
||
stored in secure area of nvram. The object consists of a 16-bit
|
||
variable in secure nvram. Bits 15-8 are product specific. Bits
|
||
7-0 are system specific."
|
||
::= { device-configure 17 }
|
||
|
||
|
||
control-panel-button-press-delay OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object gives the number of seconds to wait before
|
||
simulating the button press when CONTROL-PANEL-BUTTON-PRESS is
|
||
next called.
|
||
Additional information:
|
||
This object gives the number of seconds to wait before
|
||
simulating the button press when CONTROL-PANEL-BUTTON-PRESS is
|
||
next called."
|
||
::= { settings-system 47 }
|
||
|
||
|
||
low-power OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the Auto Low Power sleep value. The device
|
||
will go into energy saving Auto Low Power mode after the print
|
||
engine has been idle for the number of seconds specified by
|
||
this object. Frida supports values of 300 until 14400 seconds.
|
||
If the value is invalid then it will return status of
|
||
PML_Status_ErrUnsupValue and will not issue command to the
|
||
engine.
|
||
Additional information:
|
||
Returns or changes the Auto Low Power sleep value. The device
|
||
will go into energy saving Auto Low Power mode after the print
|
||
engine has been idle for the number of seconds specified by
|
||
this object. The product supports values of 0 (Off), 60 (1
|
||
minute), 900 (15 minutes), 1800 (30 minutes), 3600 (1 hour),
|
||
7200 (2 hours), and 14400 (4 hours).
|
||
If the value is invalid then it will return a status of
|
||
PML_ERROR_INVALID_OR_UNSUPPORTED_VALUE and will not issue
|
||
a command to the engine."
|
||
::= { settings-system 49 }
|
||
|
||
|
||
control-panel-display-contrast OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eLightest(1),
|
||
eLight(2),
|
||
eMedium(3),
|
||
eDark(4),
|
||
eDarkest(5)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object returns or sets the display contrast setting if the
|
||
control panel has a display and it supports contrast
|
||
adjustment. The setting Is stored in NVRAM, so the value is
|
||
saved over power cycles.
|
||
Additional information:
|
||
This object returns or sets the display contrast setting
|
||
if the control panel has a display and it supports
|
||
contrast adjustment. The setting is stored in NVRAM,
|
||
so the value is saved over power cycles."
|
||
::= { settings-system 73 }
|
||
|
||
|
||
on-off-line OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOnline(1),
|
||
eOffline(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "To bring the PDL processing sub-system on or off line. If the
|
||
device is a printer, then the printer does not process print
|
||
job data when the printer is off line. PML communication
|
||
persists.
|
||
Additional information:
|
||
The value of this object is eOnline
|
||
whenever the printer is in the ready state. This object
|
||
will return eOffline only when an alert is active. For
|
||
example, the printer will go eOffline if the cover is
|
||
open, if the toner cartridge is removed, or if the paper
|
||
trays are all empty. It is not possible to change the
|
||
state of the printer with this object. "
|
||
::= { status-system 5 }
|
||
|
||
|
||
continue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eInitiateAction(1),
|
||
eRetry(2),
|
||
eRetryAndCheck(3),
|
||
eUseLoadedMedia(4),
|
||
eEjectAndWait(5),
|
||
eSelectMediaSize(6)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "A device can support a class of errors called continuable
|
||
errors. When a continuable error is encountered, the device
|
||
requires a continue event to occur before the device will
|
||
continue operation. One continue event is setting the CONTINUE
|
||
object to eInitiateAction. Devices can support other continue
|
||
events, like auto-continue. A continue event causes the
|
||
continuable error to be acknowledged, thus allowing the device
|
||
to continue. Each device needs to list the continuable errors.
|
||
If the device doesn't currently have an unacknowledged
|
||
continuable error, the response will contain
|
||
<genErr>.
|
||
Additional information:
|
||
Consult the Control Panel ERS for a
|
||
list of continuable errors."
|
||
::= { status-system 6 }
|
||
|
||
|
||
auto-continue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates if the device will automatically continue after
|
||
encountering a continuable error. If AUTO-CONTINUE is set to
|
||
eOn, the device will automatically generate continue event to
|
||
acknowledge continuable errors. If AUTO-CONTINUE is set to
|
||
eOff, then some other continue event will have to acknowledge
|
||
the continuable error."
|
||
::= { status-system 7 }
|
||
|
||
|
||
install-date OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..14))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Identifies the date that the device was installed. The format
|
||
of the string is 'YYYYMMDDHHmmZ'. Where:
|
||
YYYY is the year.
|
||
MM is the month (1-12).
|
||
DD is the day (1-31).
|
||
HH is the hour of the day (0-23).
|
||
mm are the minutes (0-59).
|
||
'Z' designates Greenwich Mean Time; if 'Z' not specified,
|
||
value is local time.
|
||
Device POS must specify the conditions for setting this
|
||
object.
|
||
Additional information:
|
||
Identifies the date that the device was installed. The
|
||
format of the string is 'YYYYMMDDHHmmZ'. Where:
|
||
YYYY is the year.
|
||
MM is the month (1-12).
|
||
DD is the day (1-31).
|
||
HH is the hour of the day (0-23).
|
||
mm are the minutes (0-59).
|
||
'Z' designates Greenwich Mean Time; if 'Z' not specified,
|
||
value is local time.
|
||
|
||
On Products without a real-time clock this
|
||
object has the inital value of 'INVALID'. While in
|
||
the invalid state the object may written to. Once the
|
||
initial install date has been written a new intall date
|
||
can not be written without resetting the object to 'INVALID'.
|
||
|
||
The behavior on products with real-time clocks is different.
|
||
The object is set to the initial real-time clock value, usually
|
||
this is '199000300000'. Manufacturing sets the real-time
|
||
clock to the correct date and sets the INSTALL-DATE to 'INVALID'.
|
||
Then when the customer turns on the printer for the first time
|
||
the install date is reset."
|
||
::= { status-system 8 }
|
||
|
||
|
||
show-address OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eAuto(3),
|
||
eOff(1)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "If this object is set to eAuto, and the device has an IP
|
||
address, the IP address of the device will be shown with the
|
||
READY message. If this object is set to eOff, the IP address
|
||
will not be shown."
|
||
::= { display-status 3 }
|
||
|
||
|
||
job-input-auto-continue-timeout OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The number of seconds the device waits after a job related
|
||
continuable error occurs before automatically continuing. An
|
||
example job related continuable error is the job requesting a
|
||
media size that is not available. After the timeout expires,
|
||
the device will continue processing the job as if a continue
|
||
event occurred, such as the front panel continue key being
|
||
pressed. If the value is -1, the device does not automatically
|
||
continue after a job related continuable error occurs. If the
|
||
value is 0, the device immediately continues. If the value is
|
||
greater than 0, the value represents the timeout value in
|
||
seconds."
|
||
::= { status-system 35 }
|
||
|
||
|
||
job-input-auto-continue-mode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the device behavior when the desired media is
|
||
not currently available.
|
||
cCancelJob - The device cancels the job. The device POS
|
||
should explain what happens if this item is not the
|
||
only item in the collection.
|
||
cAutoMediaSizeOverride - The device is allowed to
|
||
substitute a different size media.
|
||
cAutoMediaNameOverride - The device is allowed to
|
||
substitute a different media name.
|
||
cUSMediaSizeOverride - The device is allowed to substitute
|
||
US media sizes (letter, etc.) for ISO media sizes (A4,
|
||
etc.).
|
||
cISOMediaSizeOverride - The device is allowed to substitute
|
||
ISO media sizes (A4, etc.) for US media sizes (letter,
|
||
etc.). "
|
||
::= { status-system 36 }
|
||
|
||
|
||
error-log-clear OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eClearErrorLog(1)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "Setting this object clears all the entries in the error log
|
||
sub-tree.
|
||
Additional information:
|
||
Setting this object removes all errors that
|
||
have been stored in the printer's non-volatile memory."
|
||
::= { status-system 38 }
|
||
|
||
|
||
control-panel-button-press OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eMenuPlusButton(2),
|
||
eMenuMinusButton(3),
|
||
eCancelJobButton(9),
|
||
eBackButton(13),
|
||
eQuestionMarkButton(14)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "Writing this object simulates pressing a button on the control
|
||
panel. Reading it will return the last key pressed either on
|
||
the control panel or via PML. The device POS will specify which
|
||
keys are supported.
|
||
Additional information:
|
||
Writing this object simulates pressing a
|
||
button on the control panel."
|
||
::= { status-system 60 }
|
||
|
||
|
||
device-mac-address OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The device's MAC address.
|
||
Additional information:
|
||
The device's MAC address."
|
||
::= { status-system 120 }
|
||
|
||
|
||
extended-print-modes-modified OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eYes(1),
|
||
eNo(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object allows the user to view whether the extended print
|
||
modes have been modified from their default settings.
|
||
Additional information:
|
||
This object allows the user to view whether the extended print
|
||
modes have been modified from their default settings."
|
||
::= { status-system 121 }
|
||
|
||
|
||
clear-nvram OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eClearUnprotectedNVRAM(1),
|
||
eClearProtectedNVRAM(2),
|
||
eClearCompleteNVRAM(3)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "Writing this object causes the specified NVRAM init option to
|
||
be performed. Depending on the option, some (or all) of the
|
||
permanent storage area will be completely erased. This object
|
||
is only writable when the SERVICE-PASSWORD has been set
|
||
correctly. NOTE: This considerably more destructive than
|
||
setting the prtGeneralReset object to ePresetToFactoryDefaults
|
||
since it destroys page counts, serial number, and other items
|
||
not normally affected by ePresetToFactoryDefaults.
|
||
eClearUnprotectedNVRAM - clears unprotected NVRAM
|
||
eClearProtectedNVRAM - clears protected NVRAM
|
||
eClearCompleteNVRAM - clears both protected nd unprotected
|
||
NVRAM."
|
||
::= { status-system 68 }
|
||
|
||
|
||
model-number OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Identifies the device model number as listed in the HP
|
||
corporate price list (e.g. C2121A for DeskJet 500C). The string
|
||
is as specific as possible. Products should note in POS if the
|
||
model number on the CPL changes but the device reports the
|
||
previous model number. If the model number changes based on the
|
||
installed options, the POS should indicate if only the base
|
||
model number is returned, or if the device senses the installed
|
||
options and returns the correct model number. If possible,
|
||
encode the model number in a symbol set (like Roman-8) that
|
||
matches the ASCII character set and limit the characters used
|
||
to ASCII characters.
|
||
Additional information:
|
||
Identifies the device model number as listed in the HP
|
||
corporate price list (e.g. C2121A for DeskJet 500C)."
|
||
::= { id 1 }
|
||
|
||
|
||
model-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Identifies the device model name (e.g. ''DeskJet 1200C''). The
|
||
string is as specific as possible. Capitalization and spacing
|
||
should match family naming conventions. Products should note in
|
||
POS if the model name on the HP corporate price list changes
|
||
but the device reports the previous device name. If the model
|
||
name changes based on the installed options, the POS should
|
||
indicate if only the base model name is returned, or if the
|
||
device senses the installed options and returns the correct
|
||
model name. If possible, encode the model name in a symbol set
|
||
(like Roman-8) that matches the ASCII character set and limit
|
||
the characters used to ASCII characters.
|
||
Additional information:
|
||
The value of this object changes based on the
|
||
installed options.
|
||
|
||
Since the value of this object is frequently used in
|
||
displaying a list of printers, it is kept relatively
|
||
short in case systems have limited width for their
|
||
display area."
|
||
::= { id 2 }
|
||
|
||
|
||
serial-number OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..10))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Identifies the serial number for the device. If the
|
||
SERIAL-NUMBER object is set by the user, then setting the
|
||
object does not need to be protected. If the SERIAL-NUMBER
|
||
object is set at the factory, then the SERVICE-PASSWORD object
|
||
must be set correctly before the SERIAL-NUMBER object is
|
||
writable. If this is a writable object, the POS should indicate
|
||
the maximum supported string length. If possible, encode the
|
||
serial number in a symbol set (like Roman-8) that matches the
|
||
ASCII character set and limit the characters used to ASCII
|
||
characters.
|
||
Additional information:
|
||
This value is initially set to the default
|
||
value of XXXXXXXXXX."
|
||
::= { id 3 }
|
||
|
||
|
||
fw-rom-datecode OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Identifies the base system firmware date code. The date code
|
||
will be encoded in the yyyymmdd format. There may be several
|
||
versions of the base system firmware. The date code associated
|
||
with the version of the base system firmware that is being used
|
||
is reported. There may be other date code objects for other
|
||
specific modules such as fonts, localization modules, etc.;
|
||
these other datecode objects are device specific."
|
||
::= { id 5 }
|
||
|
||
|
||
device-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "User defined device name. The POS should indicate the maximum
|
||
supported string length. If the user entered string is too
|
||
long, the device will store as much as possible and will return
|
||
the <OKNearestLegal ValueSubstituted>.Additional information:
|
||
The maximum supported string length is 32
|
||
characters. If the user entered string is too long, the
|
||
device will store the first 32 characters and will
|
||
return the <noError> status."
|
||
::= { id 10 }
|
||
|
||
|
||
asset-number OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..8))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "User defined asset number. The POS should indicate the maximum
|
||
supported string length. If the user entered string is too
|
||
long, the device will store as much as possible and will return
|
||
the <OKNearestLegal ValueSubstituted>.Additional information:
|
||
The maximum supported string length is 8
|
||
characters. If the user entered string is too long, the
|
||
device will store the first 8 characters and will return
|
||
the <noError> status."
|
||
::= { id 12 }
|
||
|
||
|
||
simm1-type OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eEmpty(1),
|
||
eUnknown(2),
|
||
eUnSupported(3),
|
||
eReadOnlyMemory(4),
|
||
eVolatileRandomAccessMemory(5),
|
||
eRamRom(9)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns an indication of the type of option installed in SIMM
|
||
slot 1.
|
||
eEmpty means the device did not detect any option installed
|
||
in the interface slot.
|
||
eUnknown means the device doesn't recognize the installed
|
||
option.
|
||
eUnSupported means the device recognizes the installed
|
||
option, but does not support the option.
|
||
eReadOnlyMemory means the installed option contains ROM
|
||
Ics.
|
||
eVolatileRandomAccessMemory means the installed option
|
||
contains RAM ICs that loose data when the power is
|
||
turned off.
|
||
eNonVolatileRandomAccessMemory means that the installed
|
||
option contains RAM ICs that do not loose data when the
|
||
power is turned off.
|
||
eFlashMemory means that the installed option contains a
|
||
type of non-volatile RAM that needs to be erased before
|
||
it can be written.
|
||
eDiskDrive means the installed option contains a disk
|
||
drive.
|
||
eRamRom means the installed option contains both volatile
|
||
random access memory and read only memory.
|
||
eInputPHD means the installed option is an input paper
|
||
handling device.
|
||
eOutputPHD means the installed option is an output paper
|
||
handling device. eIOCard means the installed option is
|
||
an I/O card.
|
||
eVolatileRAMOnBoardMemory means the installed option
|
||
contains on board RAM ICs that loose data when the
|
||
power is turned off.
|
||
Additional information:
|
||
This object is used to describe DIMMs
|
||
instead of SIMMs on the product. eRamRom is
|
||
used to denote a combo dimm."
|
||
::= { simm1 4 }
|
||
|
||
|
||
simm1-capacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns an indication of the capacity of the SIMM installed in
|
||
SIMM slot 1. The capacity is dependent on the type of option,
|
||
as indicated by the SIMM1-TYPE object. This object has no
|
||
meaning if the installed option type is eUnknown or
|
||
eReadOnlyMemory. This object contains the size, in bytes, if
|
||
the installed option type is eVolatileRandomAccessMemory,
|
||
eNonVolatileRandomAccessMemory, eFlashMemory, or eDiskDrive. If
|
||
the type of the installed option is eRamRom, this object
|
||
contains the size, in bytes, of the random access memory. If
|
||
the type of the installed option is eInputPHD, the capacity
|
||
indicates the number of input trays supported by the installed
|
||
option. If the type of the installed option is eOutputPHD, the
|
||
capacity indicates the number of output bins supported by the
|
||
installed option. If the type of the installed option is
|
||
eIOCard, the capacity indicates the number of logical I/O ports
|
||
supported by the I/O card.
|
||
Additional information:
|
||
Returns an indication of the capacity of
|
||
the installed option in bytes. This object is not
|
||
supported unless the SIMM1-TYPE type is
|
||
eVolatileRandomAccessMemory or eRamRom. For eRamRom
|
||
only the size of the Ram portion of the simm (dimm) is
|
||
returned."
|
||
::= { simm1 5 }
|
||
|
||
|
||
usb-product-id OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the Product ID of a connected USB device as defined in
|
||
the Standard Device Descriptor of the Universal Serial Bus
|
||
Specification Version 2.0. The value will be in the range
|
||
0..65535."
|
||
::= { usb 5 }
|
||
|
||
|
||
self-test OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNotInASelfTest(1),
|
||
eNonDestructiveSelfTest(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Writing this object allows a device self test to be started.
|
||
Reading this object provides an indication what self-test is
|
||
currently executing, if any. Actual self-test operation is
|
||
device specific. A self test may not be allowed at any
|
||
arbitrary time. If the device supports the requested self test,
|
||
but can not start the execution of the self test when
|
||
requested, the device will respond with
|
||
<genErr>. If a non-destructive self
|
||
test is being started, the device will generate a response
|
||
before the self test is completed. RECOMMENDATION: If the
|
||
device is ready (i.e. the NOT-READY-PRINTER object does not
|
||
contain any items, except maybe being off-line) and is idle
|
||
(i.e. the NOT-IDLE object does not contain any items), this
|
||
request should always succeed. This provides a mechanism for
|
||
driver writers to always determine if the action will succeed
|
||
or not.
|
||
Additional information:
|
||
The eNonDestructiveSelfTest performs
|
||
limited testing on the printer and its attached paper
|
||
handling devices. After the self-test is complete a
|
||
configuration page is printed. The recommended way to
|
||
cause a configuration page to be printed is to use the
|
||
PRINT-INTERNAL-PAGE object. A continuous self test
|
||
cannot be started or terminated using this OID.
|
||
|
||
When the printer is idle, setting this object to
|
||
eNonDestructiveSelfTest results in a status of <noError> and
|
||
a value of eNonDestructiveSelfTest being returned. If
|
||
the printer is not idle (whether printing an external
|
||
job, printing an internal page or running self test), a
|
||
status of <genErr> status will
|
||
be returned with a value of eNotInASelfTest.
|
||
|
||
When the printer is idle, setting this object to
|
||
eNonDestructiveSelfTest causes the configuration page to
|
||
be formatted and put in the printer's print queue.
|
||
|
||
Attempting to set this object before the configuration
|
||
page has completed being formatted and printed will
|
||
cause <genErr> status to be
|
||
returned with a value of eNotInASelfTest.
|
||
|
||
After the configuration page is in the queue, a get on
|
||
this object will return a value of eNotInASelfTest.
|
||
|
||
Setting the value to eNotInASelfTest is not supported on
|
||
the product. Once the test has started, it
|
||
will finish printing.
|
||
|
||
Likewise, if the PRINT-INTERNAL-PAGE object is set to a
|
||
valid value and that page has not printed when this
|
||
object is set to eNonDestructiveSelfTest, a status of
|
||
<genErr> status with a value of
|
||
eNotInASelfTest will be returned until the internal page
|
||
has printed."
|
||
::= { test 1 }
|
||
|
||
|
||
print-internal-page OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNotPrintingAnInternalPage(1),
|
||
ePrintingAnUnknownInternalPage(2),
|
||
eDeviceDemoPage1ConfigurationPage(3),
|
||
eDeviceDemoPage2(4),
|
||
eDeviceDemoPage7MenuMap(9),
|
||
eDeviceUsagePage(10),
|
||
eServicePage(13),
|
||
eSuppliesPage(101),
|
||
eDeviceCleaningPage(253),
|
||
ePCLFontList1(350),
|
||
ePCLXLFontList1(353),
|
||
ePostScriptFontList1(450),
|
||
eNetworkConfigPage(1200),
|
||
eFaxActivityLogPage(1304),
|
||
ePrintQualityDiagnosticPage(1409),
|
||
eColorUsageLog(1412)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Writing this object to a value other than
|
||
eNotPrintingAnInternalPage causes the device to attempt to
|
||
print an internally generated page. Reading this object
|
||
provides an indication what internally generated page is
|
||
currently being printed, if any. The actual page is device
|
||
specific. Some devices may support continuously printing an
|
||
internally generated page. Setting this object to
|
||
eNotPrintingAnInternalPage terminates continuously printing
|
||
internally generated pages. An internally generated page may
|
||
not be allowed to be printed at any arbitrary time; under what
|
||
conditions it will succeed or fail is device specific. If the
|
||
device supports the requested page, but can not start printing
|
||
the page when requested, the device will respond with
|
||
<genErr>. RECOMMENDATION: If the
|
||
device is ready (i.e. the NOT-READY-PRINTER object does not
|
||
contain any items, except maybe being off-line) and is idle
|
||
(i.e. the NOT-IDLE object does not contain any items), this
|
||
request should always succeed. This provides a mechanism for
|
||
driver writers to always determine if the action will succeed
|
||
or not.
|
||
Additional information:
|
||
eDeviceDemoPage2 is the printer demo page.
|
||
ePCLFontList1 is the PCL typeface list,
|
||
ePostScriptFontList1 is the PostScript font list, and
|
||
eDeviceDemoPage1ConfigurationPage is the selftest page.
|
||
|
||
The product does not support continuously
|
||
printing a demo page.
|
||
|
||
The printer will queue requests if it is currently busy.
|
||
|
||
When this object is set to a valid value and the printer
|
||
is idle, the status returned is <noError> and the value
|
||
returned is ePrintingAnUnknownInternalPage.
|
||
|
||
Setting this object to a valid value causes the desired
|
||
page to be formatted and put in the printer's print
|
||
queue. While the page is being formatted, and the
|
||
printer remains in a testing state, a get on this object
|
||
will return the value ePrintingAnUnknownInternalPage.
|
||
The return value will be eNotPrintingAnInternal page if
|
||
the printer is not in a testing state, and the internal
|
||
page is done being formatted.
|
||
|
||
The user will not be able to set
|
||
eNotPrintingAnInternalPage or
|
||
ePrintingAnUnknownInternalPage, and the return status
|
||
will be <badValue> with a return
|
||
value of eNotPrintingAnInternalPage.
|
||
|
||
ePostScriptFontList1 and ePCLFontList1 will not be
|
||
valid values unless postscript and PCL, respectively,
|
||
are installed in the printer. If postscript (PCL)
|
||
is not installed and the user attempts to set
|
||
ePostScriptFontList1 (ePCLFontList1), the return status
|
||
will be <badValue> with a return
|
||
value of eNotPrintingAnInternalPage.
|
||
|
||
Setting through DMCMD will cause a 15 second delay in
|
||
printing."
|
||
::= { test 2 }
|
||
|
||
|
||
job-info-change-id OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(16))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the current value of an object in the job-info sub-tree
|
||
whose value has changed. Define the object identifier for the
|
||
object whose value has changed as
|
||
job-info.required-field.optional-field.job-id. job-info
|
||
represents the OID prefix of all objects in the job-info
|
||
sub-tree. Required-field represents the OID field value that
|
||
follows the job-info prefix. Since some objects in the job-info
|
||
sub-tree have two OID fields between the job-info prefix and
|
||
the job-id, the optional-field represents the OID field between
|
||
the required-field and the job-id field, if present. Using this
|
||
definition, the format for the JOB-INFO-CHANGE-ID binary value
|
||
can be described as follows:
|
||
Bytes 0-3 : required-field
|
||
Bytes 4-7 : optional-field, or all zeros if there
|
||
is no optional field
|
||
Bytes 8-11: Job ID.
|
||
Bytes 12-n : The value of the object job-info.
|
||
required-field.optional-field.job-id.
|
||
All multi-byte values stored in Motorola (big-endian) format,
|
||
where the most significant byte occurs first.
|
||
Additional information:
|
||
The product will use this object
|
||
to report changes of the job-info-pages-printed and
|
||
job-info-state objects. The required-field (bytes 0
|
||
through 3) will designate whether the change to be
|
||
reported involves the pages printed (13) or job state
|
||
(15). The optional-field (bytes 4 through 7) will
|
||
always be zeroes. The value-field (bytes 12 through 15)
|
||
will contain the new value for pages printed or job
|
||
state cast to a 32-bit integer."
|
||
::= { settings-job 3 }
|
||
|
||
|
||
current-job-parsing-id OBJECT-TYPE
|
||
SYNTAX INTEGER(-1..32767)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains the printer assigned job identification for the job
|
||
currently being processed by the processing PDL sub-system. The
|
||
job ID is a monotonically increasing number. The job ID may be
|
||
reset to zero at power-up and may roll over to zero after
|
||
reaching some maximum value.
|
||
Additional information:
|
||
A value of -1 is returned when the printer
|
||
is not parsing a job.
|
||
|
||
When data for a new job is detected, this object is
|
||
updated (the job may or may not turn out to be a Null
|
||
Job). (A job is considered to be a 'null job' if it has
|
||
no name or job attribute, causes no pages to be printed,
|
||
and consumes MIN_JOB_SIZE (9) or fewer bytes.) See the
|
||
Job Boundary ERS for details on what constitutes a job
|
||
boundary.
|
||
|
||
Some job-info- objects are created when the first data
|
||
bytes are received. If the printer determines that the
|
||
job is a Null Job, the job-info- objects related to the
|
||
Null Job are deleted. The product retains
|
||
the job-info- objects for the MAX_JOBS_IN_LIST (12) most
|
||
recent jobs that are not Null Jobs.
|
||
|
||
The first job received after power-up will have job ID 1,
|
||
and the job ID will increment to 32767 before rolling
|
||
to zero. To distinguish whether a power cycle or a
|
||
rollover causes a reduction in the job ID value, the
|
||
object prtGeneralConfigChanges can be watched and if it
|
||
increments at the same time as the drop is observed in
|
||
the value of CURRENT-JOB-PARSING-ID, then a power cycle
|
||
is the most likely cause."
|
||
::= { job-being-parsed 1 }
|
||
|
||
|
||
job-info-name1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains the first part of this print job's name. The last OID
|
||
field for this dynamic object contains the job ID.
|
||
Additional information:
|
||
The job name is the string specified by the
|
||
NAME= parameter of the @PJL JOB command which allows a
|
||
maximum of 80 characters. The first 40 characters are
|
||
in this object and the second 40 are in job-info-name2.
|
||
The symbol set is Roman-8.
|
||
|
||
When jobs are nested, the value assigned to this object
|
||
is the name provided by the most recent @PJL JOB NAME=
|
||
command. If no name is provided, a null string is
|
||
returned."
|
||
::= { job-info 1 }
|
||
|
||
|
||
job-info-name2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains the second part of this print job's name. The last OID
|
||
field for this dynamic object contains the job ID.
|
||
Additional information:
|
||
See job-info-name1-1."
|
||
::= { job-info 2 }
|
||
|
||
|
||
job-info-stage OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates what printer sub-systems are currently processing
|
||
this print job. The last OID field for this dynamic object
|
||
contains the job ID. cSourceSubsystem - some of the job is in
|
||
the printer I/O subsystem. cProcessingSubsystem - some of the
|
||
job is in the printer imaging processing subsystem.
|
||
cDestinationSubsystem - some of the job is being printed.
|
||
Additional information:
|
||
For the product, cSourceSubsystem
|
||
and cProcessingSubsystem will always be set and cleared
|
||
together. They are set when the beginning of the job is
|
||
detected, and they are cleared when the end of the job
|
||
is parsed.
|
||
|
||
A non-printing job will never set
|
||
cDestinationSubsystem.
|
||
|
||
When a page is ready to be printed (the intermediate has
|
||
been built and the page is 'closed' by the personality),
|
||
cDestinationSubsystem will be set even if a page of a
|
||
previous job is currently being printed.
|
||
cDestinationSubsystem remains set until the last page of
|
||
the job has finished printing.
|
||
|
||
If a page requires extensive processing and allows all
|
||
the previous pages of a job to complete printing
|
||
cDestinationSubsystem will remain set until the last
|
||
page of the job has finished printing."
|
||
::= { job-info 10 }
|
||
|
||
|
||
job-info-io-source OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates which I/O source, the print job was received over.
|
||
The value maps to port numbering scheme supported in the
|
||
DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree.
|
||
Additional information:
|
||
The product does not
|
||
support the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
|
||
::= { job-info 11 }
|
||
|
||
|
||
job-info-pages-processed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the number of pages processed by the processing
|
||
subsystem. If neither the cSourceSubsystem or the
|
||
cProcessingSubsystem items are in the associated JOB-INFO-STAGE
|
||
object, then this object contains the total number of pages
|
||
processed for this job. The last OID field for this dynamic
|
||
object contains the job ID.
|
||
Additional information:
|
||
This object is incremented by one when a
|
||
page is processed ('closed' by the personality),
|
||
regardless of the number of pages that are printed as a
|
||
result of the single page processed. In other words, it
|
||
does not matter how many identical copies of a page are
|
||
printed, or no pages may be printed if operating in
|
||
silent run mode, this count is incremented exactly once
|
||
per page processed.
|
||
|
||
A page is considered processed when all of the input
|
||
data has been processed for a page (that is, when the
|
||
intermediate has been produced and the personality has
|
||
'closed' the page). At this time, the image of the page
|
||
is not necessarily completely formed."
|
||
::= { job-info 12 }
|
||
|
||
|
||
job-info-pages-printed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the number of pages printed by the destination
|
||
subsystem. If none of the cSourceSubsystem,
|
||
cProcessingSubsystem or cDestinationSubsystem items are in the
|
||
associated JOB-INFO-STAGE object, then this object contains the
|
||
total number of pages printed for this job. This value may
|
||
increase by two each time for duplex jobs. The last OID field
|
||
for this dynamic object contains the job ID.
|
||
Additional information:
|
||
If multiple copies of a page are printed,
|
||
each copy is counted individually."
|
||
::= { job-info 13 }
|
||
|
||
|
||
job-info-size OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the number of bytes of data processed by the
|
||
processing subsystem. If neither of the cSourceSubsystem or
|
||
cProcessingSubsystem items are in the associated JOB-INFO-STAGE
|
||
object, then this object contains the size of this job, in
|
||
bytes. The last OID field for this dynamic object contains the
|
||
job ID.
|
||
Additional information:
|
||
This count may be incremented by values
|
||
other than one as blocks of data are processed; blocks
|
||
of data (which may be as large as 2K bytes) will be
|
||
processed in a varying amount of time.
|
||
|
||
During the processing of a job and even when a job
|
||
completes, an exact count of the number of I/O bytes
|
||
processed by teh job is not necessarily expected."
|
||
::= { job-info 14 }
|
||
|
||
|
||
job-info-state OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eAborted(3),
|
||
eWaitingForResources(4),
|
||
ePrinted(5),
|
||
eTerminating(7),
|
||
eCancelled(10),
|
||
eProcessing(11)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the state of the job. The last OID field for this
|
||
dynamic object contains the job ID.
|
||
eAborted - the print job was aborted.
|
||
eWaitingForResources - the print job requires resources
|
||
that are not currently available. Example resources
|
||
that can cause the job to wait include the print engine
|
||
or PDL processor being unavailable. The print engine
|
||
could be unavailable due to paper out, paper jam,
|
||
staple out, stapler jam, marking agent low, output bin
|
||
full, etc. The PDL processor could be unavailable due
|
||
to an off-line condition. Each printer specific object
|
||
specification should state which conditions cause a job
|
||
to be waiting for resources and also state which
|
||
objects can be retrieved by an application to determine
|
||
the exact cause of a resource being unavailable.
|
||
ePrinted - the job has printed. The related JOB-INFO-
|
||
OUTCOME object indicates if any problems were
|
||
encountered while the job was processed.
|
||
eRetained - the job can be reprinted.
|
||
eTerminating - the job was aborted or cancelled and is
|
||
currently is terminating.
|
||
eInterrupted - the job has been interrupted. The job can be
|
||
continued.
|
||
ePaused - the job has been paused. The job can be
|
||
continuted.
|
||
eCancelled - the job has been cancelled.
|
||
eProcessing - the job is currently being printed normally.
|
||
eStored - The job is stored on the device and can be retrieved
|
||
and printed at a later point in time."
|
||
::= { job-info 15 }
|
||
|
||
|
||
job-info-outcome OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOk(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates if any warning or error conditions were encountered
|
||
while processing the assoicated job. The last OID field for
|
||
this dynamic object contains the job ID.
|
||
Additional information:
|
||
In the product, warnings
|
||
and errors are not recorded in this object. Although no
|
||
meaningful information can be obtained from this object,
|
||
it is kept around for the compatibility needs of
|
||
existing software."
|
||
::= { job-info 19 }
|
||
|
||
|
||
job-info-outbins-used OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates which output bins this job has delivered printed
|
||
pages to. The last OID field for this dynamic object contains
|
||
the job ID.
|
||
Additional information:
|
||
The product has only 1 output bin.
|
||
cOutbin1 is the top/face-down bin."
|
||
::= { job-info 20 }
|
||
|
||
|
||
job-info-physical-outbins-used OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates which physical output bins this job has delivered
|
||
printed pages to. The last OID field for this dynamic object
|
||
contains the job ID.
|
||
Additional information:
|
||
The product only has one output
|
||
bin so this will always be set to cOutbin1.
|
||
cOutbin1--Face-up bin"
|
||
::= { job-info 22 }
|
||
|
||
|
||
job-info-attr-1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. Attribute objects are saved sequentially, starting
|
||
with 1, after the start of a job. If more attributes are set
|
||
than there are objects to store them, the excess JOBATTR values
|
||
are ignored. If the corresponding SET JOBATTR= command has not
|
||
been received when a get is done for this object, a status of
|
||
<noSuchName> will be returned."
|
||
::= { job-info-attribute 1 }
|
||
|
||
|
||
job-info-attr-2 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 2 }
|
||
|
||
|
||
job-info-attr-3 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 3 }
|
||
|
||
|
||
job-info-attr-4 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 4 }
|
||
|
||
|
||
job-info-attr-5 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 5 }
|
||
|
||
|
||
job-info-attr-6 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 6 }
|
||
|
||
|
||
job-info-attr-7 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 7 }
|
||
|
||
|
||
job-info-attr-8 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 8 }
|
||
|
||
|
||
job-info-attr-9 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 9 }
|
||
|
||
|
||
job-info-attr-10 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 10 }
|
||
|
||
|
||
job-info-attr-11 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 11 }
|
||
|
||
|
||
job-info-attr-12 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 12 }
|
||
|
||
|
||
job-info-attr-13 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 13 }
|
||
|
||
|
||
job-info-attr-14 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 14 }
|
||
|
||
|
||
job-info-attr-15 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 15 }
|
||
|
||
|
||
job-info-attr-16 OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(1..80))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns the value that was set in PJL via the SET JOBATTR=
|
||
command. See JOB-INFO-ATTR-1 for details."
|
||
::= { job-info-attribute 16 }
|
||
|
||
|
||
error1-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 1
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
This item contains the engine page count
|
||
when the error occurred.
|
||
|
||
If there is currently no error entry for this object, a
|
||
'0' will be returned. If ERROR1-CODE object also
|
||
returns '0', then an error has not yet been logged for
|
||
this object
|
||
|
||
See ERROR1-CODE for an explanation of the order used for
|
||
storing errors."
|
||
::= { error1 1 }
|
||
|
||
|
||
error1-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
Returns a device specific error code. If
|
||
the error code returned is '0', then the printer has not
|
||
yet logged an error for this object. When the maximum
|
||
number of errors is reached (10 on the
|
||
product), and a new error occurs, the error in
|
||
ERROR1-CODE will be replaced by the one in ERROR2-CODE,
|
||
and so on until the last error object will be given the
|
||
value of the new error.
|
||
|
||
The error category is returned in the upper 16 bits,
|
||
either 79 (for service) or 0 (for support). The lower
|
||
16 bits encodes the specific error. If an error is not
|
||
a 79 service error, the value of this object is the PJL
|
||
USTATUS code. If it is a 79 service error, the lower 16
|
||
bits contain the PJL USTATUS code.
|
||
|
||
The types of errors reported for the product are:
|
||
49 Service Error
|
||
50-67 Service Error
|
||
69 Service Error
|
||
70-72 Service Error
|
||
79 Service Errors
|
||
Access Error
|
||
Address Error
|
||
ASIC fault
|
||
Asserts
|
||
Bad Beam Detect
|
||
Bad E-Label
|
||
Bad Fan
|
||
Bad Fuser
|
||
Bad Malfunction
|
||
Bad MIO
|
||
Bad Scanner Motor
|
||
Data Communication Error
|
||
Engine Communication Error
|
||
Format Error
|
||
Genunine HP Supply Installed
|
||
Illegal Instruction
|
||
Insufficient Memory
|
||
Invalid Personality
|
||
Laser Malfunction
|
||
MIO Buffer Overflow
|
||
MIO Connection Break
|
||
Missing E-Label
|
||
Non-HP Supply Detected
|
||
NVRAM Error
|
||
NVRAM Service Error
|
||
Parallel Buffer Overflow
|
||
Print Page Punt
|
||
Priviledge Violation
|
||
Trace Fault
|
||
Unimplemented Line-a Opcode
|
||
Unimplemented Line-f Opcode
|
||
Uninitialized Interrupt"
|
||
::= { error1 2 }
|
||
|
||
|
||
error2-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 2
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error2 1 }
|
||
|
||
|
||
error2-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error2 2 }
|
||
|
||
|
||
error3-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 3
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error3 1 }
|
||
|
||
|
||
error3-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error3 2 }
|
||
|
||
|
||
error4-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 4
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error4 1 }
|
||
|
||
|
||
error4-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error4 2 }
|
||
|
||
|
||
error5-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 5
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error5 1 }
|
||
|
||
|
||
error5-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error5 2 }
|
||
|
||
|
||
error6-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 6
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error6 1 }
|
||
|
||
|
||
error6-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error6 2 }
|
||
|
||
|
||
error7-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 7
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error7 1 }
|
||
|
||
|
||
error7-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error7 2 }
|
||
|
||
|
||
error8-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 8
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error8 1 }
|
||
|
||
|
||
error8-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error8 2 }
|
||
|
||
|
||
error9-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 9
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error9 1 }
|
||
|
||
|
||
error9-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error9 2 }
|
||
|
||
|
||
error10-time-stamp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains some sort of time stamp indicating when error 10
|
||
occurred. Example time stamps include the actual time the error
|
||
occurred (in seconds since Jan. 1, 1970), and the total engine
|
||
page count. The device POS documents the meaning of the time
|
||
stamp.
|
||
Additional information:
|
||
See ERROR1-TIME-STAMP."
|
||
::= { error10 1 }
|
||
|
||
|
||
error10-code OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Contains a device specific error code. Each device POS should
|
||
list what errors are logged to the error log and the meaning of
|
||
each supported error code value.
|
||
Additional information:
|
||
See ERROR1-CODE."
|
||
::= { error10 2 }
|
||
|
||
|
||
firmware-download-version OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object will return a string value representing the current
|
||
revision of firmware that the printer is operating with. This
|
||
is used to determine if code needs to be upgraded when an
|
||
firmware bundle comes in, in an upgrade job.
|
||
Additional information:
|
||
This object will return a string value representing the current
|
||
revision of firmware that the printer is operating with. This
|
||
is used to determine if code needs to be upgraded when an
|
||
firmware bundle comes in, in an upgrade job."
|
||
::= { firmware-download 7 }
|
||
|
||
|
||
io-timeout OBJECT-TYPE
|
||
SYNTAX INTEGER(5..7200)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The amount of time, in seconds, to wait for more print job data
|
||
to be received before an I/O timeout occurs. The I/O channel
|
||
being timed is the I/O channel that received the data
|
||
associated with the current print job. If an I/O timeout
|
||
occurs, the PDL processing sub-system assumes all the data
|
||
associated with the current print job has been received, and
|
||
processes the end of job in a PDL specific manner. The POS
|
||
specifies the supported values.
|
||
Additional information:
|
||
If an I/O timeout occurs,the PDL processing
|
||
sub-system will consider it an end of job condition only
|
||
if there is data from another I/O subsystem waiting to be
|
||
processed.
|
||
The supported values are 5 to 7200 seconds. Setting to a
|
||
value outside the supported range returns
|
||
<badValue> status."
|
||
::= { settings-io 1 }
|
||
|
||
|
||
io-switch OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eYes(1)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates if the device will switch between I/O channels when a
|
||
job boundary is encountered and print job data is available on
|
||
another I/O channel."
|
||
::= { settings-io 2 }
|
||
|
||
|
||
default-copies OBJECT-TYPE
|
||
SYNTAX INTEGER(1..999)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes default copies. Default copies is the
|
||
default values used by the PDL to control the number of copies
|
||
of each page in the print job that are printed. The print job
|
||
can override this value. The list of supported values should be
|
||
documented in the device POS.
|
||
Additional information:
|
||
The supported values are 1 through 999.
|
||
Setting to an unsupported value causes the printer to
|
||
substitute in a snap value and to return
|
||
<noError> status.
|
||
The snaps are as follows:
|
||
<1 snaps to
|
||
>999 snaps to 999"
|
||
::= { settings-pdl 4 }
|
||
|
||
|
||
default-vertical-black-resolution OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the value of the default vertical black
|
||
resolution. The units are dots per inch.
|
||
Additional information:
|
||
In the product, changing this OID
|
||
also causes DEFAULT-HORIZONTAL-BLACK RESOLUTION to
|
||
change. DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
|
||
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
||
same. The supported values are 600, and 1200.
|
||
When the default monochrome resolution or bits-per-pixel
|
||
are changed to anything other than 600x1 the product
|
||
no longer prints color jobs. Color jobs are always 600x1.
|
||
|
||
Setting to an unsupported value causes the printer to
|
||
substitute in a snap value and to return
|
||
<noError> status.
|
||
|
||
The snap values are as follows:
|
||
<450 will snap to 600
|
||
>=450 and <900 will snap to 600
|
||
>=900 will snap to 1200"
|
||
::= { settings-pdl 8 }
|
||
|
||
|
||
default-horizontal-black-resolution OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the value of the default horizontal black
|
||
resolution. The units are dots per inch.
|
||
Additional information:
|
||
In the product, changing this OID
|
||
also causes DEFAULT-VERTICAL-BLACK RESOLUTION to change.
|
||
DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
|
||
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
||
same. The supported values are 600 and 1200. When the default
|
||
monochrome resolution or bits-per-pixel are changed to
|
||
anything other than 600x1 the product no longer prints color
|
||
jobs. Color jobs are always 600x1.
|
||
|
||
|
||
Setting to an unsupported value causes the printer to
|
||
substitute in a snap value and to return
|
||
<noError> status.
|
||
|
||
The snap values are as follows:
|
||
<450 snaps to 600
|
||
>=450 and <900 snaps to 600
|
||
>=900 snaps to 1200"
|
||
::= { settings-pdl 9 }
|
||
|
||
|
||
default-lines-per-page OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the default number of lines per page. The
|
||
POS indicates the supported values. An unsupported value causes
|
||
the printer to use the closest supported value, causing the
|
||
printer to return the <noError>.
|
||
Additional information:
|
||
The supported values in the product
|
||
are 5 to 128. Setting to an unsupported value
|
||
causes the printer to substitute in a snap value and to
|
||
return <noError> status.
|
||
|
||
The snap values are as follows:
|
||
<5 snaps to 5
|
||
>128 snaps to 128"
|
||
::= { settings-pdl 11 }
|
||
|
||
|
||
default-vmi OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the default vertical motion index. The unit
|
||
of measure for VMI is centipoints per line. The POS indicates
|
||
the supported values. An unsupported value causes the printer
|
||
to use the closest supported value, causing the printer to
|
||
return <noError>.
|
||
Additional information:
|
||
Setting this object may cause
|
||
DEFAULT-LINES-PER-PAGE to change."
|
||
::= { settings-pdl 12 }
|
||
|
||
|
||
default-media-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eFoolscap(10),
|
||
eROC16K(17),
|
||
eISOandJISA6(24),
|
||
eISOandJISA5(25),
|
||
eISOandJISA4(26),
|
||
ePRC16K195X270(34),
|
||
eJISB5(45),
|
||
eJapanesePostcardSingle(71),
|
||
eJapanesePostcardDouble(72),
|
||
eIndexCard5x8(75),
|
||
ePhoto4x6(76),
|
||
eMonarch(80),
|
||
eCommercial10(81),
|
||
eROC16K184X260(89),
|
||
eInternationalDL(90),
|
||
eInternationalC5(91),
|
||
eInternationalB5(100),
|
||
eCustom(101),
|
||
ePhoto10x15(118)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This indicates the default media size. A write of an
|
||
unsupported value causes an <ErrorInvalidOrUnsupported Value>. Complete list of supported media sizes along with their
|
||
dimensions are listed in the ''Media Size Table'' near the end
|
||
of this document. (for a full list of media size enums see the
|
||
end of this file) "
|
||
::= { settings-pdl 13 }
|
||
|
||
|
||
cold-reset-media-size OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSLetter(2),
|
||
eISOandJISA4(26)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the media size that is used as the
|
||
DEFAULT-MEDIA-SIZE when a cold reset occurs."
|
||
::= { settings-pdl 19 }
|
||
|
||
|
||
default-media-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the media name that is used until the media
|
||
name is changed by a print job command.
|
||
Additional information:
|
||
This string must be one of the MEDIAn-NAME
|
||
objects, except it cannot be set to ANY.
|
||
The value of this object is saved across
|
||
a power cycle."
|
||
::= { settings-pdl 22 }
|
||
|
||
|
||
reprint OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2),
|
||
eAuto(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the reprint (jam recovery) setting. If eOn,
|
||
then the device will reprint pages jammed pages. If eOff, the
|
||
device will not attempt to reprint jammed pages. If eAuto, a
|
||
device dependent algorithm (which should be documented in the
|
||
POS) will be used to determine if the page gets reprinted. This
|
||
object controls all PDLs, unless a specific PDL supports its
|
||
own reprint control mechanism. To date, only PostScript has a
|
||
PDL reprint control mechanism.
|
||
Additional information:
|
||
Setting this object when the printer is not
|
||
idle, may cause a status of <noError> to be returned, but
|
||
the new value will not take effect until a job boundary
|
||
is reached. If a get is done on object before the job
|
||
boundary is reached, the value last set will be
|
||
returned.
|
||
|
||
When the value is set to eOff, pages will not be stored
|
||
in the printer, and in the event of a paper jam, will
|
||
have to be reprinted. When the value is set to eOn,
|
||
pages will be stored until delivery, therefore, in the
|
||
event of a paper jam, the page will be reprinted.
|
||
|
||
When the value is set to eAuto, the printer will behave
|
||
as though it is eOff when there is less than seven
|
||
megabytes of memory installed in the printer. When
|
||
additional memory is installed, to total at least seven
|
||
megabytes of RAM, the setting of eAuto will behave as
|
||
though it was set to eOn."
|
||
::= { settings-pdl 36 }
|
||
|
||
|
||
wide-a4 OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the wide A4 logical page size setting. If
|
||
eOn, then the margins/printable area of A4 paper will be
|
||
changed to allow 80 10-pitch characters to be printed on a
|
||
single line. If eOff then the industry standard A4 logical page
|
||
size is used."
|
||
::= { settings-pdl 37 }
|
||
|
||
|
||
dark-courier OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the dark Courier setting. If eOn, then the
|
||
Courier font used will approximate the same darkness as the
|
||
LaserJet III printer. If eOff, then the Courier font used will
|
||
approximate the same darkness as the LaserJet 4 printer."
|
||
::= { settings-pdl 38 }
|
||
|
||
|
||
default-bits-per-pixel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Controls the number of levels used (per pixel) when printing
|
||
grayscale or color images."
|
||
::= { settings-pdl 39 }
|
||
|
||
|
||
pcl-total-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of PCL pages printed by the device."
|
||
::= { pdl-pcl 5 }
|
||
|
||
|
||
pcl-default-font-height OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the default PCL height. Height is an
|
||
approximate measure of the body of the type in centipoints. A
|
||
centipoint is 1/7200 inch. Height applies only to proportional
|
||
fonts. Point size, in points, can be converted to font height,
|
||
in centipoints, by multiplying the point size by 100. The POS
|
||
indicates the supported values. An unsupported value causes the
|
||
printer to use the closest supported value, causing the printer
|
||
to return <noError>. ''Closest'' means
|
||
the smallest absolute difference.
|
||
Additional information:
|
||
This object refers to the font point size
|
||
with 400 representing the smallest settable font (4) and
|
||
99975 representing the largest settable font (999.75).
|
||
The default of 1200 is a font point size of 12.
|
||
|
||
Supported values range from 400 to 99975. Setting to an
|
||
unsupported value causes the printer to substitute in a
|
||
snap value and to return
|
||
<noError> status.
|
||
|
||
The snap values are as follows:
|
||
<=400 snaps to 400
|
||
>=99975 snaps to 99975
|
||
|
||
Fonts are settable to the nearest quarter point size
|
||
(i.e. 10, 10.25, 10.50, 10.75). Unsupported values in
|
||
the range 401 to 99974 snap DOWN to the previous
|
||
supported value (i.e 25293 snaps to 25275 or 75038 snaps
|
||
to 75025)."
|
||
::= { pdl-pcl 13 }
|
||
|
||
|
||
pcl-default-font-source OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eInternal(1),
|
||
ePermanentSoft(2),
|
||
eRomSimm1(10)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the value of the default font source
|
||
variable in NVRAM."
|
||
::= { pdl-pcl 14 }
|
||
|
||
|
||
pcl-default-font-number OBJECT-TYPE
|
||
SYNTAX INTEGER(0..255)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the value of the default font number
|
||
variable in NVRAM. Writing an unsupported value causes the
|
||
printer to generate an <badValue>.
|
||
Additional information:
|
||
Valid numbers or 0 - 255, but only font
|
||
numbers that are included in the PCL FONT LIST are
|
||
selectable."
|
||
::= { pdl-pcl 15 }
|
||
|
||
|
||
pcl-default-font-width OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the default PCL font width. Width is
|
||
expressed as the width of a character in centipoints. A
|
||
centipoint is 1/7200 inch. Width applies only to fixed space
|
||
fonts. Pitch, in character per inch, can be converted to font
|
||
width, in centipoints, by dividing 7200 by the pitch. The POS
|
||
indicates the supported values. An unsupported value causes the
|
||
printer to use the closest supported value, causing the printer
|
||
to return <noError>. ''Closest'' means
|
||
the smallest absolute difference.
|
||
Additional information:
|
||
Setting to an unsupported value causes the
|
||
printer to substitue in a snap value (listed below) and
|
||
return <noError> status.
|
||
|
||
The snap values for pitch are as follow:
|
||
<=44 snaps to 44
|
||
>=9999 snaps to 9999
|
||
|
||
Unsupported values in the range 44 - 9999 (.44 - 99.99)
|
||
snap DOWN to the next supported value."
|
||
::= { pdl-pcl 16 }
|
||
|
||
|
||
postscript-total-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of PostScript pages printed by the device."
|
||
::= { pdl-postscript 5 }
|
||
|
||
|
||
postscript-print-errors OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the value of the print PostScript errors
|
||
setting. If eOn, PostScript prints an error page showing the
|
||
error encountered and the stack at the time of the error.
|
||
Additional information:
|
||
Returns or changes the value of the print PostScript errors
|
||
setting. If eOn, PostScript prints an error page showing the
|
||
error encountered and the stack at the time of the error."
|
||
::= { pdl-postscript 11 }
|
||
|
||
|
||
pclxl-total-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of PCLXL pages printed by the device."
|
||
::= { pdl-pclxl 1 }
|
||
|
||
|
||
pjl-password OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns PJL password, if the password is not set (zero). If the
|
||
password is set, then attempting to retrieve the password
|
||
causes an <genErr> to occur and will return
|
||
the <NullValue>."
|
||
::= { pjl 1 }
|
||
|
||
|
||
default-duplex-mode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eSimplex(1),
|
||
eDuplexVerticalBinding(2),
|
||
eDuplexHorizontalBinding(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the duplex printing mode. Duplex printing is
|
||
when printing occurs on both sides of a sheet of media.
|
||
Vertical binding is also called long edge binding or book
|
||
binding. Horizontal binding is also called short edge binding
|
||
or calendar binding.
|
||
Additional information:
|
||
Returns or sets the duplex printing mode. Duplex printing is
|
||
when printing occurs on both sides of a sheet of media.
|
||
Vertical binding is also called long edge binding or book
|
||
binding. Horizontal binding is also called short edge binding
|
||
or calendar binding."
|
||
::= { settings-prt-eng 4 }
|
||
|
||
|
||
print-density OBJECT-TYPE
|
||
SYNTAX INTEGER(1..5)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or sets the print density setting. Print density is the
|
||
instantaneous amount of marking agent applied to the paper
|
||
while printing. A value of zero has the lowest print density,
|
||
yielding a lighter page. A value of 10 has the highest print
|
||
density, yielding a darker page. Each POS should document what
|
||
values in the 0 to 10 range are supported.
|
||
Additional information:
|
||
When this value is written, the page
|
||
pipeline will be flushed (all pages being printed are
|
||
completed, no new ones are started), the new density
|
||
setting is set and printing resumes. The acutal change
|
||
in print density may be gradual over several pages.
|
||
|
||
The supported values are 1 through 5. Setting to an
|
||
unsupported value causes the printer to substitue in a
|
||
a snap value and to return <noError>
|
||
status.
|
||
|
||
The snap values are as follows:
|
||
<1 snaps to 1
|
||
>5 snaps to 5."
|
||
::= { settings-prt-eng 5 }
|
||
|
||
|
||
invalid-personality-reports-enabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eDisabled(1),
|
||
eEnabled(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Read or configure wether invalid personality reports are
|
||
enabled or disabled for a product."
|
||
::= { settings-prt-eng 18 }
|
||
|
||
|
||
fast-first-page-out OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Return or set the value of the fast first page out setting.
|
||
Additional information:
|
||
Return or set the value of the fast first page out setting."
|
||
::= { settings-prt-eng 19 }
|
||
|
||
|
||
supplies-at-very-low-setting OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eStopAtOut(2),
|
||
eOverrideAtOut(4),
|
||
ePromptAtOut(6),
|
||
ePrintBlack(7)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object can be used to change the setting of menu item AT
|
||
VERY LOW. The behavior of the printer when a supply reaches low
|
||
changes in accordance with the setting of this PML Object. If
|
||
the option eStopAtOut is selected then printer will stop when a
|
||
supply reaches Estimated End of Life (EEOL). If the option
|
||
eOverrideAtOut is selected then printer will continue past EEOL
|
||
in override mode. If the option eOverrideAtOut is selected then
|
||
printer will continue past EEOL in override mode. If the option
|
||
ePromptAtOut is selected then printer will ask the user if they
|
||
wish to continue printing past EEOL in override mode. If the
|
||
option eAutoContinueBlack is selected then printer will
|
||
continue printing in mono past EEOL. This may be subject to
|
||
page limits. (Color only) NOTE: This object replaces
|
||
SUPPLIES-REPLACE-ACTION-AT-SETTING"
|
||
::= { settings-prt-eng 38 }
|
||
|
||
|
||
total-engine-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of pages printed by the device. POS indicates if
|
||
the total engine page count is kept in NVRAM, and the maximum
|
||
supported value before the page count rolls over to zero.
|
||
Additional information:
|
||
This object is stored in NVRAM. The maximum value of
|
||
this count is 1000000 before it rolls over to zero."
|
||
::= { status-prt-eng 5 }
|
||
|
||
|
||
print-engine-jam-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of pages jammed in the print engine's life time.
|
||
The POS indicates if the total jam count is kept in NVRAM and
|
||
the maximum supported value before the jam count rolls over to
|
||
zero.
|
||
Additional information:
|
||
This object is stored in NVRAM. The maximum value of
|
||
this count is 65000 before it rolls over to zero."
|
||
::= { status-prt-eng 34 }
|
||
|
||
|
||
print-engine-mispick-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of pages mispicked in the print engine's life
|
||
time. The POS indicates if the total mispick count is kept in
|
||
NVRAM and the maximum supported value before the mispick count
|
||
rolls over to zero.
|
||
Additional information:
|
||
This object is stored in NVRAM. The maximum value of
|
||
this count is 65000 before it rolls over to zero."
|
||
::= { status-prt-eng 35 }
|
||
|
||
|
||
supply-out-device-state OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNoSupplyOut(1),
|
||
eOffline(2),
|
||
eSupplyOutOverride(3),
|
||
eMonochromePrintingAfterColorCartridgeOut(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This PML object indicates the current behavior of the device if
|
||
one or more supplies have reached out. If no supply has reached
|
||
out, the value of this PML object is eNoSupplyOut. If one or
|
||
more supplies have reached out, the value of this PML object
|
||
will indicate if the printer is online and if so what mode is
|
||
being used to continue printing.
|
||
Additional information:
|
||
This PML object indicates the current behavior of the device if
|
||
one or more supplies have reached out. If no supply has reached
|
||
out, the value of this PML object is eNoSupplyOut. If one or
|
||
more supplies have reached out, the value of this PML object
|
||
will indicate if the printer is online and if so what mode is
|
||
being used to continue printing. If the printer is in both
|
||
eSupplyOutOverride and eMonochromePrintingAfterColorCartridgeOut
|
||
then eMonochromePrintingAfterColorCartridgeOut will be returned."
|
||
::= { status-prt-eng 49 }
|
||
|
||
|
||
duplex-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER(0..1000000)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Total number of sheets of media that have been duplex printed.
|
||
A sheet is counted if it travels through the duplex page path,
|
||
regardless of whether or not marks are made on the page. The
|
||
POS will indicate if the value is kept in NVRAM.
|
||
Additional information:
|
||
Total number of sheets of media that have been duplex printed.
|
||
A sheet is counted if it travels through the duplex page path,
|
||
regardless of whether or not marks are made on the page.
|
||
This object is stored in NVRAM. The maximum value of
|
||
this count is 1000000 before it rolls over to zero."
|
||
::= { status-prt-eng 22 }
|
||
|
||
|
||
print-engine-revision OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Print engine revision string.
|
||
Additional information:
|
||
Print engine revision string."
|
||
::= { status-prt-eng 26 }
|
||
|
||
|
||
mp-tray OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eManual(1),
|
||
eCassette(2),
|
||
eFirst(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the value of the multi-purpose (MP) tray
|
||
configuration variable. The MP tray can be configured to
|
||
operate as an additional input tray (eCassette), a manual feed
|
||
slot (eManual), or in a manner compatible with the LaserJet III
|
||
manual feed slot (eFirst). If configured for eFirst, if media
|
||
is present in the MP tray, that media is used (assuming the
|
||
size matches and the print job didn't specify another tray)
|
||
until the MP tray is empty.
|
||
Additional information:
|
||
Returns or changes the value of the multi-purpose (MP) tray
|
||
configuration variable. The MP tray can be configured to
|
||
operate as an additional input tray (eCassette), a manual feed
|
||
slot (eManual), or in a manner compatible with the LaserJet III
|
||
manual feed slot (eFirst). If configured for eFirst, if media
|
||
is present in the MP tray, that media is used (assuming the
|
||
size matches and the print job didn't specify another tray)
|
||
until the MP tray is empty."
|
||
::= { settings-intray 5 }
|
||
|
||
|
||
tray-lock OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the list of locked input trays. The printer
|
||
only pulls media from a locked input tray when the input tray
|
||
is specifically requested by the print job.
|
||
Additional information:
|
||
Returns or changes the list of locked input trays. The printer
|
||
only pulls media from a locked input tray when the input tray
|
||
is specifically requested by the print job."
|
||
::= { settings-intray 6 }
|
||
|
||
|
||
custom-paper-dim-unit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTenThousandthsOfInches(3),
|
||
eMicrometers(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The units of measure used to specify the width and height of
|
||
the printer's custom paper. The unit of measure of
|
||
eTenThousandthsOfInches is 0.0001 inches.
|
||
Additional information:
|
||
The only valid values for this object are
|
||
eTenThousandthsOfInches (3), and eMicrometers (4). The
|
||
data for this object is stored in NVRAM."
|
||
::= { settings-intray 7 }
|
||
|
||
|
||
custom-paper-feed-dim OBJECT-TYPE
|
||
SYNTAX INTEGER(50000..140000)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Sets the printer's custom paper dimension in the feed direction
|
||
(direction parallel to the direction of paper feeding). The
|
||
value for this object is specified in micrometers or
|
||
tenthousandths of an inch, depending upon the value of
|
||
CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and
|
||
should be documented in the POS for each product.
|
||
Additional information:
|
||
The valid range is 50000 to 140000 if
|
||
CUSTOM-PAPER_DIM_UNIT is eTenThousandthsOfInches or 127000 to
|
||
355600 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers. Attempts
|
||
to set this object outside the valid range will result in a
|
||
return value of ERROR_INVALID_OR_UNSUPPORTED_VALUE."
|
||
::= { settings-intray 8 }
|
||
|
||
|
||
custom-paper-xfeed-dim OBJECT-TYPE
|
||
SYNTAX INTEGER(30000..85000)
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Sets the printer's custom paper dimension in the cross-feed
|
||
direction (direction ninety degrees relative to the direction
|
||
of paper feeding). The value for this object is specified in
|
||
micrometers or tenthousandths of an inch, depending upon the
|
||
value of CUSTOM-PAPER-DIM-UNIT. The valid range is
|
||
engine-dependent and should be documented in the POS for each
|
||
product.
|
||
Additional information:
|
||
The valid range for the product
|
||
is 30000 to 85000 if CUSTOM-PAPER-DIM-UNIT is
|
||
eTenThousandthsOfInches or 76200 to 215900 if
|
||
CUSTOM-PAPER-DIM-UNIT is ePmicrometers. Attempts to set
|
||
this object outside the valid range will result in a
|
||
return value of <badValue>."
|
||
::= { settings-intray 9 }
|
||
|
||
|
||
tray1-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eFoolscap(10),
|
||
eROC16K(17),
|
||
eISOandJISA6(24),
|
||
eISOandJISA5(25),
|
||
eISOandJISA4(26),
|
||
eROC16K195X270(34),
|
||
eJISB5(45),
|
||
eJapansePostcardSingle(71),
|
||
eJapansePostcardDouble(72),
|
||
eIndexCard5x8(75),
|
||
ePhoto4x6(76),
|
||
eMonarch(80),
|
||
eCommercial10(81),
|
||
eROC16K184X260(89),
|
||
eInternationalDL(90),
|
||
eInternationalC5(91),
|
||
eInternationalB5(100),
|
||
eCustom(101),
|
||
ePhoto10x15(118),
|
||
eAnySize(32765)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns the media size that is currently configuredconfigured
|
||
in tray #1. This object can be set to indicate the media size
|
||
currently loaded, if the printer supports input trays that can
|
||
not sense the media size. Complete list of supported media
|
||
sizes along with their dimensions are listed in the ''Media
|
||
Size Table'' near the end of this document."
|
||
::= { intray1 1 }
|
||
|
||
|
||
tray1-fuser-temperature OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The fuser temperature to be used when printing media from Tray
|
||
1. The value zero is the default temperature. Values less than
|
||
zero are progressively lower and values greater than zero are
|
||
progressively higher. The range of values supported is device
|
||
specific.
|
||
Additional information:
|
||
The fuser temperature to be used when printing media from Tray
|
||
1. The value zero is the default temperature. Values less than
|
||
zero are progressively lower and values greater than zero are
|
||
progressively higher. The range of values supported is device
|
||
specific."
|
||
::= { intray1 13 }
|
||
|
||
|
||
tray2-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eFoolscap(10),
|
||
eROC16K(17),
|
||
eISOandJISA6(24),
|
||
eISOandJISA5(25),
|
||
eISOandJISA4(26),
|
||
eROC16K195X270(34),
|
||
eJISB5(45),
|
||
eJapansePostcardSingle(71),
|
||
eJapansePostcardDouble(72),
|
||
eIndexCard5x8(75),
|
||
ePhoto4x6(76),
|
||
eMonarch(80),
|
||
eCommercial10(81),
|
||
eROC16K184X260(89),
|
||
eInternationalDL(90),
|
||
eInternationalC5(91),
|
||
eInternationalB5(100),
|
||
eCustom(101),
|
||
ePhoto10x15(118),
|
||
eAnySize(32765)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns the media size that is currently configured in tray #2.
|
||
Complete list of supported media sizes along with their
|
||
dimensions are listed in the ''Media Size Table'' near the end
|
||
of this document."
|
||
::= { intray2 1 }
|
||
|
||
|
||
tray2-fuser-temperature OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The fuser temperature to be used when printing media from Tray
|
||
2. The value zero is the default temperature. Values less than
|
||
zero are progressively lower and values greater than zero are
|
||
progressively higher. The range of values supported is device
|
||
specific.
|
||
Additional information:
|
||
The fuser temperature to be used when printing media from Tray
|
||
2. The value zero is the default temperature. Values less than
|
||
zero are progressively lower and values greater than zero are
|
||
progressively higher. The range of values supported is device
|
||
specific."
|
||
::= { intray2 13 }
|
||
|
||
|
||
tray3-media-size-loaded OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eUSExecutive(1),
|
||
eUSLetter(2),
|
||
eUSLegal(3),
|
||
eFoolscap(10),
|
||
eROC16K(17),
|
||
eISOandJISA5(25),
|
||
eISOandJISA4(26),
|
||
eROC16K195X270(34),
|
||
eJISB5(45),
|
||
eAnySize(32765)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns the media size that is currently configured in tray #3.
|
||
Complete list of supported media sizes along with their
|
||
dimensions are listed in the ''Media Size Table'' near the end
|
||
of this document."
|
||
::= { intray3 1 }
|
||
|
||
|
||
tray3-fuser-temperature OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The fuser temperature to be used when printing media from Tray
|
||
3. The value zero is the default temperature. Values less than
|
||
zero are progressively lower and values greater than zero are
|
||
progressively higher. The range of values supported is device
|
||
specific.
|
||
Additional information:
|
||
The fuser temperature to be used when printing media from Tray
|
||
3. The value zero is the default temperature. Values less than
|
||
zero are progressively lower and values greater than zero are
|
||
progressively higher. The range of values supported is device
|
||
specific."
|
||
::= { intray3 13 }
|
||
|
||
|
||
default-ret OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eLight(2),
|
||
eMedium(3),
|
||
eDark(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the Resolution Enhancement Technology
|
||
setting. Devices that only support eOff and eOn should map all
|
||
other values to eOn and always return the same non-eOff value
|
||
to indicate on. The list of supported values should be
|
||
documented in the device POS."
|
||
::= { imaging 5 }
|
||
|
||
|
||
media-names-available OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of this object controls which of the MEDIAx-NAME
|
||
objects are supported. If a bit is set to zero, then attempting
|
||
to get or set the corresponding MEDIAx-NAME objects will return
|
||
<noSuchName>.
|
||
Additional information:
|
||
Since this object is read-only, the corresponding MEDIAx
|
||
objects will always be available. The DEFAULTS below
|
||
represent which MediaNameX is available on this product
|
||
of the total possible available defined in SYNTAX, so the
|
||
collection is like a bitfield. Raptor does not support
|
||
cMediaName32Available"
|
||
::= { settings-print-media 1 }
|
||
|
||
|
||
media1-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 1 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media1 1 }
|
||
|
||
|
||
media1-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
The engine processing characteristics that are to
|
||
be applied to this media type. Currently, 'engine
|
||
processing characteristics' denotes changes to
|
||
fusing temperature and/or transfer roller voltage."
|
||
::= { media1 4 }
|
||
|
||
|
||
media2-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 2 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media2 1 }
|
||
|
||
|
||
media2-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media2 4 }
|
||
|
||
|
||
media3-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 3 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media3 1 }
|
||
|
||
|
||
media3-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media3 4 }
|
||
|
||
|
||
media4-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 4 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media4 1 }
|
||
|
||
|
||
media4-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media4 4 }
|
||
|
||
|
||
media5-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 5 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media5 1 }
|
||
|
||
|
||
media5-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media5 4 }
|
||
|
||
|
||
media6-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 6 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media6 1 }
|
||
|
||
|
||
media6-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media6 4 }
|
||
|
||
|
||
media7-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 7 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media7 1 }
|
||
|
||
|
||
media7-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media7 4 }
|
||
|
||
|
||
media8-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 8 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media8 1 }
|
||
|
||
|
||
media8-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media8 4 }
|
||
|
||
|
||
media9-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 9 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media9 1 }
|
||
|
||
|
||
media9-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media9 4 }
|
||
|
||
|
||
media10-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 10 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media10 1 }
|
||
|
||
|
||
media10-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media10 4 }
|
||
|
||
|
||
media11-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 11 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media11 1 }
|
||
|
||
|
||
media11-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media11 4 }
|
||
|
||
|
||
media12-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 12 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media12 1 }
|
||
|
||
|
||
media12-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media12 4 }
|
||
|
||
|
||
media13-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 13 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media13 1 }
|
||
|
||
|
||
media13-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media13 4 }
|
||
|
||
|
||
media14-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 14 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media14 1 }
|
||
|
||
|
||
media14-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media14 4 }
|
||
|
||
|
||
media15-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 15 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media15 1 }
|
||
|
||
|
||
media15-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media15 4 }
|
||
|
||
|
||
media16-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 16 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media16 1 }
|
||
|
||
|
||
media16-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media16 4 }
|
||
|
||
|
||
media17-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 17 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media17 1 }
|
||
|
||
|
||
media17-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media17 4 }
|
||
|
||
|
||
media18-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 18 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media18 1 }
|
||
|
||
|
||
media18-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media18 4 }
|
||
|
||
|
||
media19-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 19 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media19 1 }
|
||
|
||
|
||
media19-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media19 4 }
|
||
|
||
|
||
media20-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 20 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media20 1 }
|
||
|
||
|
||
media20-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media20 4 }
|
||
|
||
|
||
media21-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 21 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media21 1 }
|
||
|
||
|
||
media21-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media21 4 }
|
||
|
||
|
||
media22-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 22 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media22 1 }
|
||
|
||
|
||
media22-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media22 4 }
|
||
|
||
|
||
media23-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 23 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media23 1 }
|
||
|
||
|
||
media23-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media23 4 }
|
||
|
||
|
||
media24-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 24 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media24 1 }
|
||
|
||
|
||
media24-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media24 4 }
|
||
|
||
|
||
media25-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 25 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media25 1 }
|
||
|
||
|
||
media25-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media25 4 }
|
||
|
||
|
||
media26-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 26 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media26 1 }
|
||
|
||
|
||
media26-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media26 4 }
|
||
|
||
|
||
media27-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 27 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media27 1 }
|
||
|
||
|
||
media27-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media27 4 }
|
||
|
||
|
||
media28-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 28 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media28 1 }
|
||
|
||
|
||
media28-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media28 4 }
|
||
|
||
|
||
media29-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 29 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media29 1 }
|
||
|
||
|
||
media29-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media29 4 }
|
||
|
||
|
||
media30-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 30 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media30 1 }
|
||
|
||
|
||
media30-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media30 4 }
|
||
|
||
|
||
media31-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 31 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media31 1 }
|
||
|
||
|
||
media31-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media31 4 }
|
||
|
||
|
||
media32-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 32 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media32 1 }
|
||
|
||
|
||
media32-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media32 4 }
|
||
|
||
|
||
media33-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 3 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media33 1 }
|
||
|
||
|
||
media33-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media33 4 }
|
||
|
||
|
||
media34-name OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Media 3 name.
|
||
Additional information:
|
||
The symbol set for this string is Roman-8."
|
||
::= { media34 1 }
|
||
|
||
|
||
media34-engine-media-mode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The engine processing characteristics that are to be applied to
|
||
this media. The processing characteristics are device
|
||
specific.
|
||
Additional information:
|
||
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
||
::= { media34 4 }
|
||
|
||
|
||
engine-media-modes-supported1 OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The list of engine media modes supported by the device. The
|
||
modes are each separated by a comma character. An example
|
||
string would be: 'Normal,Rough,Low,Vellum'."
|
||
::= { media-modes 1 }
|
||
|
||
|
||
pe-test-cause-assert OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
e49DEAD(1),
|
||
e494C02(2),
|
||
e4900FF(3),
|
||
e80DEAD(4),
|
||
e81DEAD(5)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "This object allows the user to cause a 49 Error.
|
||
Additional information:
|
||
This object allows the user to cause a 49 Error."
|
||
::= { print-engine-test 111 }
|
||
|
||
|
||
pe-test-cause-79error OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
e79DEAD(1)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "This object allows the user to cause a 79 Error.
|
||
Additional information:
|
||
This object allows the user to cause a 79 Error."
|
||
::= { print-engine-test 116 }
|
||
|
||
|
||
consumable-status-serial-number OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object is used to report the serial number for this
|
||
consumable."
|
||
::= { consumable-status 3 }
|
||
|
||
|
||
consumable-status-partnumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object will have one sub-array for the consumable and will
|
||
will hold the consumable's part number.
|
||
Additional information:
|
||
This object will have one sub-array for the consumable and will
|
||
will hold the consumable's part number."
|
||
::= { consumable-status 56 }
|
||
|
||
|
||
consumable-reorder-url OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..64))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object is used to read and write the URL that can be used
|
||
to reorder consumables for this device. This URL is set at the
|
||
factory but can be updated by a reseller or third party.
|
||
Additional information:
|
||
The URL can be up to 64 characters long."
|
||
::= { consumables 2 }
|
||
|
||
|
||
consumable-pages-printed-with-supply OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This PML object returns the number of pages printed with a
|
||
cartridge consumable. This PML object returns the value that
|
||
should be displayed under 'Pages Printed With This Supply' for
|
||
cartridges in color products."
|
||
::= { consumables 11 }
|
||
|
||
|
||
consumable-life-usage-units-remaining OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object reports the current estimate of the number of usage
|
||
units that remain before this supply is depleted. An installed
|
||
supply that cannot report such a number will return a value of
|
||
-2. It is the reponsibility of the host application to query
|
||
each supply in order to determine an overall device
|
||
USAGE-UNITS-REMAINING number - the lowest value returned. The
|
||
unit of measure for this life estimate is determined by reading
|
||
the corresponding CONSUMABLE-LIFE-USAGE-UNITS object.
|
||
Additional information:
|
||
This object reports the approximate number of pages remaining
|
||
before this supply reaches very low. An installed cartridge that
|
||
cannot report such a number (because supply status is not
|
||
available) will return a value of -2. If the supply life is above
|
||
80% then this object will return ErrorActionCanNotBePerformedNow
|
||
(or genErr if queried through SNMP)."
|
||
::= { consumables-life 1 }
|
||
|
||
|
||
consumable-life-low-threshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object is used to report and modify a threshold value
|
||
indicating the point in the life of a consumable or supply at
|
||
which a transition to a LOW state will occur."
|
||
::= { consumables-life 3 }
|
||
|
||
|
||
consumable-test-password OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "When set with the correct integer password value this object is
|
||
used to enable certain device specific test capabilities. When
|
||
set with any incorrect integer value, this object is used to
|
||
disable any device specific features previously enabled by this
|
||
object. This object will return a response of
|
||
<noSuchName> whenever an attempt is made to
|
||
query the object rather than
|
||
<noSuchName> so as to hide the
|
||
existence of this object from external host applications."
|
||
::= { consumables-test 1 }
|
||
|
||
|
||
scanner-jam-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates a count of the total pages jammed in the
|
||
scanner'slifetime."
|
||
::= { settings-scanner 43 }
|
||
|
||
|
||
scanner-adf-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates a count of the total pages scanned through the ADF on
|
||
the device. This may include scan to host jobs, copyjobs, and
|
||
fax jobs. If only the total pages scanned to the host are
|
||
wanted, use SCAN-ADF-PAGE-COUNT."
|
||
::= { settings-scanner 44 }
|
||
|
||
|
||
scan-adf-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Indicates the total pages scanned through the ADF to the host
|
||
from the device. If the total pages scanned through the scanner
|
||
are needed for all features, including copy and fax jobs, use
|
||
the SCANNER-ADF-PAGE-COUNT object."
|
||
::= { settings-scanner 45 }
|
||
|
||
|
||
scanner-retrieve-scanline OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object facilitates the sending of a scan line of data from
|
||
the scanner to a host. It grabs either raw or corrected data.
|
||
SERVICE-PASSWORD must be set correctly to use this object.
|
||
cScannerRequestRawScanLine - This is set by the host in
|
||
order to signal to the firmware that it wants a scan
|
||
line of raw (no PRNU or DSNU correction)data to be sent
|
||
back up to the host.
|
||
cScannerRequestCorrectedScanLine - This is set by the host
|
||
in order to signal to the firmware that it wants a scan
|
||
line of corrected (PRNU or DSNU correction) data to be
|
||
sent back up to the host.
|
||
cScannerSendDataRequest - This is set by firmware to
|
||
indicate that it has acquired the scan line from scan
|
||
engine and is ready to send the data to the host.
|
||
cScannerSendDataOK - This is set by the host to indicate
|
||
that it is ready to receive the data from the device.
|
||
|
||
cScannerSendDataDone - This is set by the firmware to
|
||
indicate that the transfer of data is complete.
|
||
cScannerPickSheet - This is set by the host to tell the
|
||
device to pick and stage the sheet of paper in the ADF.
|
||
|
||
cScannerFlushSheet - This is set by the host to tell the
|
||
device to flush the sheet of paper currently in the
|
||
device.
|
||
Additional information:
|
||
This object is meant to be used by Manufacturing
|
||
in order to facilitate the sending of a scan line of data from
|
||
the scanner over HDT. It
|
||
grabs either raw or corrected data.
|
||
|
||
cScannerRequestRawScanLine - This is set by the host in order
|
||
to signal to the firmware that it wants an scan line of raw
|
||
(no PRNU or DSNU correction)data to be sent back up to the
|
||
host.
|
||
|
||
cScannerRequestCorrectedScanLine - This is set by the host in
|
||
order to signal to the firmware that it wants a scan line of
|
||
corrected (PRNU or DSNU correction) data to be sent back up to
|
||
the host.
|
||
|
||
cScannerSendDataRequest - This is set by firmware to indicate
|
||
that it has acquired the scan line from scan engine and is
|
||
ready to send the data to the host.
|
||
|
||
cScannerSendDataOK - This is set by the host to
|
||
indicate that it is ready to receive the data from the device.
|
||
|
||
cScannerSendDataDone - This is set by the firmware to indicate
|
||
that the transfer of data is complete.
|
||
|
||
cScannerPickSheet - This is used for manufacturing to drop the
|
||
scan bogey to prevent damage during shipping. For LaserJet
|
||
3200, it was used to load a sheet in the ADF for shipping.
|
||
|
||
cScannerFlushSheet - This is set by the host to tell the
|
||
device to flush the sheet of paper currently in the device."
|
||
::= { settings-scanner 48 }
|
||
|
||
|
||
scanner-motor-control OBJECT-TYPE
|
||
SYNTAX INTEGER(-500..4680)
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "This objects is set to the number of steps that the scan motor
|
||
should move. SERVICE-PASSWORD must be set correctly to use this
|
||
object.
|
||
Additional information:
|
||
This objects is set to the number of steps that
|
||
the scan motor should move. It is meant to be used by Manufacturing
|
||
in order to position the scanner shipping blocks.
|
||
The minimum value is -500, and the maximum is 4680. The value
|
||
set for this object will move the scan motor relative to the
|
||
home position. A value of 0 will use the find home algorithm
|
||
to move the scan motor home."
|
||
::= { settings-scanner 49 }
|
||
|
||
|
||
scanner-scanline-statistics OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object is used to obtain statistics about the scan line
|
||
that was previously obtained using the
|
||
SCANNER-RETRIEVE-SCANLINE object. Just as SERVICE-PASSWORD must
|
||
be set correctly for SCANNER-RETRIEVE-SCANLINE; it must be set
|
||
correctly to use this object as well.
|
||
Additional information:
|
||
This object is used to obtain statistics about
|
||
the scan line that was previously grabbed using the SCANNER_
|
||
RETRIEVE_SCANLINE object, max string is 256 bytes. The format
|
||
is the following: max red value; position; min red value; position;
|
||
max red pixel to pixel difference; position; red mean; max blue value;
|
||
position; min blue value; position; max blue pixel to pixel difference;
|
||
position; blue mean; max green value; position; min green value;
|
||
position; max green pixel to pixel difference; position; green mean;"
|
||
::= { settings-scanner 51 }
|
||
|
||
|
||
scan-control-descriptor OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Describes the control language and formats supported for this
|
||
scanner.
|
||
Additional information:
|
||
This string is also used by Jetdirect Embedded WebScan"
|
||
::= { settings-scanner 52 }
|
||
|
||
|
||
scan-flatbed-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages scanned from
|
||
the flatbed."
|
||
::= { settings-scanner 73 }
|
||
|
||
|
||
scanner-flatbed-page-count OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object tracks the page count for the pages scanned for all
|
||
jobs from the flatbed. This includes scan to host jobs, fax
|
||
jobs, and copy jobs. "
|
||
::= { settings-scanner 74 }
|
||
|
||
|
||
scanner-modular-hardware OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Used to specify whether optional hardware is installed or not.
|
||
Additional information:
|
||
This HP LaserJet MFP uses this object to allow
|
||
a host to query whether or not it has an ADF installed,
|
||
Letter/A4 flatbed, or Legal flatbed."
|
||
::= { settings-scanner 75 }
|
||
|
||
|
||
scanner-clock-edge-modifiers OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "This object accesses a table used by firmware to modify clock
|
||
edge values for CCD scanner modules.
|
||
Additional information:
|
||
This object accesses a table used by firmware to modify
|
||
clock edge values for CCD scanner modules."
|
||
::= { settings-scanner 84 }
|
||
|
||
|
||
scan-clock-edges OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Returns a table of clock edges used by the scanner.
|
||
Additional information:
|
||
Returns a table of clock edges used by the scanner."
|
||
::= { settings-scanner 85 }
|
||
|
||
|
||
scan-emulate-copy OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eYes(1),
|
||
eNo(2)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Setting this object to eYes will cause firmware to run the next
|
||
scan job as if it were a copy job, using copy values for
|
||
scanner h/w and image processing, and then return the data to
|
||
the host as if it were a scan job. Setting this object to eNo
|
||
will cause firmware to process scan jobs in the normal way.
|
||
Additional information:
|
||
Setting this object to eYes will cause firmware to run
|
||
the next scan job as if it were a copy job, using copy
|
||
values for scanner h/w and image processing, and then
|
||
return the data to the host as if it were a scan job.
|
||
Setting this object to eNo will cause firmware to
|
||
process scan jobs in the normal way."
|
||
::= { settings-scanner 86 }
|
||
|
||
|
||
scan-calibration-target OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eWhiteSheet(1),
|
||
ePlaten(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object is used by the host to check which type of
|
||
calibration this scan device supports. The device pos will
|
||
describe the meaning and intent of each type of scan
|
||
calibration supported.
|
||
Additional information:
|
||
This object is used by the host to check which
|
||
type of calibration the firmware supports."
|
||
::= { scan-calibration 18 }
|
||
|
||
|
||
not-ready-source-scanner OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates whether and why the scanner is not ready. A set bit
|
||
indicates a problem.
|
||
Additional information:
|
||
ISSUES: Timberline only used
|
||
cScannerFeederJam. Tahiti does not have
|
||
an ADF sensor. Can cScannerFeederEmpty still
|
||
be used (i.e. when the device tries to pull
|
||
a page, but the ADF is empty or a mispick
|
||
occurred). cInvalidScannerMediaSize may be used.
|
||
If a page is longer that 33 inches normally this would be
|
||
shown to the host as a Jam. However, can the device
|
||
use cInvalidScannerMediaSize instead?"
|
||
::= { status-scanner 1 }
|
||
|
||
|
||
scan-calibration-download OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Returns or changes the state of the calibration operation.
|
||
cScanCalibrationIdle - This indicates that the device is
|
||
not currently processing a
|
||
calibration request. The host
|
||
should not set the object to this state.
|
||
SCAN-CALIBRATION-ERROR state
|
||
will reflect results of most
|
||
recent calibration.
|
||
cScanCalibrationActive - The device sets this state to
|
||
indicate it is in calibration
|
||
mode. The device will set
|
||
SCAN-CALIBRATION-ERROR to eNoError(1) as a consequence
|
||
of entering this state.
|
||
cScanCalibrationOptical - This state is set by the host to
|
||
request factory optical
|
||
calibration initiation. The
|
||
device should not set to this state. The device will
|
||
ignore this request, without
|
||
error, if it is already in the
|
||
active or the done state.
|
||
cScanCalibrationADFFaceUpMechanical - This state is set by
|
||
the host to request factory
|
||
face up ADF mechanical calibration
|
||
initiation. The calibration
|
||
target should be placed face up in the ADF.
|
||
The device should not set to
|
||
this state. The device will
|
||
ignore this request, without error, if
|
||
it is already in the active or
|
||
the done state.
|
||
cScanCalibrationADFFaceDownMechanical - This state is set
|
||
by the host to request factory
|
||
face down ADF mechanical calibration
|
||
initiation. The calibration
|
||
target should be placed face down in the ADF.
|
||
The device should not set to
|
||
this state. The device will
|
||
ignore this request, without error, if
|
||
it is already in the active or
|
||
the done state.
|
||
cScanCalibrationFBMechanical - This state is set by the
|
||
host to request factory flat
|
||
bed mechanical calibration
|
||
initiation. The device should not set to this state.
|
||
The device will ignore this
|
||
request, without error, if it
|
||
is already in the active state.
|
||
cScanCalibrationADFResetMechanical - This state is set by
|
||
the host if he wants to start
|
||
ADF mechanical calibration all
|
||
over again. If this is set then both Face Up and Face
|
||
Down calibration can be started
|
||
even after a successful pass.
|
||
The device will NOT print a calibration graph when calibration
|
||
is complete.
|
||
Additional information:
|
||
Returns or changes the state of the calibration
|
||
operation.
|
||
cScanCalibrationIdle - indicates that calibration is not
|
||
in progress.
|
||
cScanCalibrationStart - This state is set by host to
|
||
request calibration initiation. Device should not set to
|
||
this state.
|
||
cScanCalibrationActive - Indicates device is in
|
||
calibration mode. Device sets cScanCalibrationActive to
|
||
signal calibration is in process.
|
||
cScanCalibrationAborted - Set by device to indicate
|
||
calibration was prematurely terminated. Set by host when
|
||
a calibration error occurs.
|
||
cScanCalibrationDone - Set by the host to inform the
|
||
device calibration is complete.
|
||
|
||
The device will print a calibration graph when
|
||
calibration is complete."
|
||
::= { status-scanner 5 }
|
||
|
||
|
||
scan-calibration-error OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eNoError(1),
|
||
eUnknownCalibrationError(2),
|
||
eScannerFeederEmpty(3),
|
||
eLowMemory(4),
|
||
eWriteFailed(5),
|
||
eScannerBusy(6),
|
||
eADFMispick(7),
|
||
eADFJam(8),
|
||
eUncorrectablePixels(9)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Error status of the most recent calibration session.
|
||
eNoError(1) - The calibation was successful.
|
||
eUnknownCalibrationError(2) - An unknown error occurred.
|
||
eScannerFeederEmpty(3) - The feeder contained nothing
|
||
to scan.
|
||
eLowMemory(4) - Insufficient memory available to complete
|
||
the calibration.
|
||
eWriteFailed(5) - Write to NVRAM failure.
|
||
eScannerBusy(6) - Scanner is busy.
|
||
Detailed information about the cause and remedy for each error
|
||
should be documented in the device POS.
|
||
Additional information:
|
||
This object was originally defined for use on
|
||
Timberline. We are proposing the new enums number 7-9.
|
||
Note: Option 9 would only be set during a factory calibration
|
||
to indicate that at least one pixel was not correctable by
|
||
the digital calibration factors."
|
||
::= { status-scanner 6 }
|
||
|
||
|
||
scanner-lamp-gain-value OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Provides PWM and analog gain for the color channels. The range
|
||
will vary based on scan mode. The device specific POS should
|
||
describe the valid range. The format is the following:
|
||
PWM value; red analog gain; green analog gain; blue analog
|
||
gain.
|
||
Additional information:
|
||
The range will vary based on scan mode. The values
|
||
will differ from those of San Diego. The initial value
|
||
can be obtained at the start of warmup and the final
|
||
value can be obtained at the end of warmup. The warmup period is about
|
||
2 minutes. The format is the following PWM value; red analog gain;
|
||
green analog gain; blue analog gain;. The valid values for PWM value
|
||
are 580 - 730 and the valid values for analog gains are 1.00-5.80.
|
||
The gains are reported with accuracy to 2 decimal places.
|
||
A sample return value would be '584;1.00;1.34;1.00;' "
|
||
::= { status-scanner 8 }
|
||
|
||
|
||
scanner-light-monitor-window OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Provides the pixel at which the LMW starts, as the ratio of the
|
||
average LMW value to the six pixel average value. The device
|
||
specific pos should specify the valid ranges for each value.
|
||
The format is the following:
|
||
LMW position; ratio of LMWavg to 6 pixel avg.
|
||
Additional information:
|
||
Provides the pixel at which the LMW starts as well as
|
||
the ratio of the average LMW value over a 6 pixel average value.
|
||
A algebraic representation of this ratio is:
|
||
Average of Light Monitor Window pixels
|
||
______________________________________
|
||
Average of 6 test point pixels
|
||
|
||
The 6 test point pixels do not inlcude any of the Light Monitor Window.
|
||
A sample return value would be '50;0.059;'. "
|
||
::= { status-scanner 9 }
|
||
|
||
|
||
scanner-reference-position OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Provides 3 pairs of x,y coordinates within a specified range of
|
||
the calibrate reference position. The device specific POS
|
||
should specify the valid ranges. The format is the following:
|
||
'x;y;x;y;x;y'
|
||
Additional information:
|
||
Provides x,y coordinates within 1/300 of a line of the
|
||
calibrate reference position. The 3 locations in order that are
|
||
reported are the 1st Reference Mark, the 2nd Reference Mark, and
|
||
the Document Origin. A sample return value would be
|
||
80,471;2523,2914;80,471;1;34326;27,32;193;35748;28,27;194;0,0;0;0;0;0;0;0;0,0;0;0;0;0;0;0;0,0;0;0,0;0;0;0
|
||
The extra 0's on the end are used specifically to gather information during
|
||
the cimation process. "
|
||
::= { status-scanner 10 }
|
||
|
||
|
||
scanner-sensor-manufacturer OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Reports the scan sensor manufacturer. The device specific POS
|
||
should list valid manufacturers.
|
||
Additional information:
|
||
Reports the scan sensor manufacturer. The device specific
|
||
POS should list valid manufacturers."
|
||
::= { status-scanner 11 }
|
||
|
||
|
||
pe-test-scanner-adf-voltage-start OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Set any attributes related to the ADF scanner voltage.
|
||
Additional information:
|
||
Set any attributes related to the ADF scanner start
|
||
voltage. Controls the ADF starve start voltage.
|
||
The possible values are 0-16 inclusive."
|
||
::= { pe-test-scanner-configuration 2 }
|
||
|
||
|
||
pe-test-scanner-adf-voltage-run OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Set any attributes related to the ADF scanner voltage.
|
||
Additional information:
|
||
Set attributes related to the ADF scanner run voltage.
|
||
Controls the ADF starve run voltage. The possible values
|
||
are 0-16 inclusive."
|
||
::= { pe-test-scanner-configuration 3 }
|
||
|
||
|
||
pe-test-scanner-flatbed-voltage-start OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Set any attributes related to the flatbed scanner voltage.
|
||
Additional information:
|
||
Set any attributes related to the flatbed scanner
|
||
start voltage.Controls the flatbed starve start voltage.
|
||
The possible values are 0-16 inclusive."
|
||
::= { pe-test-scanner-configuration 4 }
|
||
|
||
|
||
pe-test-scanner-flatbed-voltage-run OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Set any attributes related to the flatbed scanner voltage.
|
||
Additional information:
|
||
Set attributes related to the flatbed scanner run
|
||
voltage.Controls the flatbed starve run voltage.
|
||
The possible values are 0-16 inclusive."
|
||
::= { pe-test-scanner-configuration 5 }
|
||
|
||
|
||
pe-test-scanner-test-config OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eOff(1),
|
||
eOn(2)
|
||
}
|
||
ACCESS write-only
|
||
STATUS optional
|
||
DESCRIPTION "Configures the device for scanner test mode.
|
||
Additional information:
|
||
Configures the device for scanner test mode."
|
||
::= { pe-test-scanner-configuration 6 }
|
||
|
||
|
||
prtGeneralConfigChanges OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Counts configuration changes that change the capabilities of
|
||
a printer, such as the addition/deletion of input/output bins,
|
||
the addition/deletion of interpreters, or changes in media
|
||
size. Such changes will often affect the capability of the
|
||
printer to service certain types of print jobs.
|
||
Management applications may cache infrequently changed
|
||
configuration information about sub-units on the printer.
|
||
This object should be incremented whenever the agent wishes
|
||
such applications to invalidate that cache and re-download
|
||
all of this configuration information, thereby signaling a
|
||
change in the printer's configuration.
|
||
For example, if an input tray that contained paper of
|
||
different dimensions was added, this counter would be
|
||
incremented.
|
||
As an additional example, this counter would not be
|
||
incremented when an input tray is removed or the level of an
|
||
input device changes.
|
||
Additional information:
|
||
This is a 32 bit counter (unsigned). When it
|
||
reaches its maximum value, it will roll to zero."
|
||
::= { prtGeneralEntry 1 }
|
||
|
||
|
||
prtGeneralCurrentLocalization OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The value of the prtLocalizationIndex corresponding to the
|
||
current language, country, and character set to be used for
|
||
localized string values that are identified as being dependent
|
||
on the value of this object. Note that this object does not
|
||
apply to localized strings in the prtConsole group or to any
|
||
object that is not explicitly identified as being localized
|
||
according to prtGeneralCurrentLocalization."
|
||
::= { prtGeneralEntry 2 }
|
||
|
||
|
||
prtGeneralReset OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePnotResetting(3),
|
||
ePpowerCycleReset(4),
|
||
ePresetToNVRAM(5),
|
||
ePresetToFactoryDefaults(6)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "Setting this value to `powerCycleReset', `resetToNVRAM', or
|
||
`resetToFactoryDefaults' will result in the resetting of the
|
||
printer. When read, this object will always have the value
|
||
`notResetting(3)', and a SET of the value `notResetting' shall
|
||
have no effect on the printer. Some of the defined values are
|
||
optional. However, every implementation must support at least
|
||
the values `notResetting' and 'resetToNVRAM'.
|
||
Additional information:
|
||
Setting this object to ePnotResetting causes the
|
||
printer to not reset.
|
||
|
||
Setting this object to ePpowerCycleReset causes this device
|
||
to do a reset.
|
||
|
||
Setting this object to 'resetToNVRAM' does NOT perform an NVRAM
|
||
init on the product. It causes the device to perform its power
|
||
on initialization routines. All I/O buffers are reset and tests
|
||
normally run at power on time are executed.
|
||
|
||
Setting the object to 'resetToFactoryDefaults, causes the
|
||
device to perform its reset to factory defaults routines.
|
||
Also, the device will perform a power cycle, which is required
|
||
to set all variables to their factory defaults."
|
||
::= { prtGeneralEntry 3 }
|
||
|
||
|
||
prtGeneralCurrentOperator OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..26))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The name of the person who is responsible for operating
|
||
this printer. It is suggested that this string include
|
||
information that would enable other humans to reach the operator,
|
||
such as a phone number. As a convention to facilitate automatic
|
||
notification of the operator by the agent or the network
|
||
management station, the phone number, fax number or email address
|
||
should be placed on a separate line starting with ASCII LF (hex
|
||
0x0A) and the ASCII text string (without the quotes): 'phone: ',
|
||
'fax: ', and 'email: ', respectively. Phone numbers may contain
|
||
digits, whitespace and parentheses, which shall be ignored. Phone
|
||
numbers may also include ASCII comma characters(hex 2C) that are
|
||
used to indicate a two-second pause during the dialing sequence.
|
||
If either the phone, fax, or email information is not available,
|
||
then a line should not be included for this information.
|
||
NOTE: For interoperability purposes, it is advisable to use email
|
||
addresses formatted according to RFC 822 requirements.
|
||
Additional information:
|
||
The maximum supported string length is 26
|
||
characters.
|
||
|
||
If the user entered string is too long, the device will store
|
||
as much as possible and will return the
|
||
<noError> status."
|
||
::= { prtGeneralEntry 4 }
|
||
|
||
|
||
prtGeneralServicePerson OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..28))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The name of the person responsible for servicing this
|
||
printer. It is suggested that this string include information
|
||
that would enable other humans to reach the service person, such
|
||
as a phone number. As a convention to facilitate automatic
|
||
notification of the service person by the agent or a network
|
||
management station, the phone number, fax number or email address
|
||
should be placed on a separate line starting with ASCII LF (hex
|
||
0x0A) and the ASCII text string (without the quotes): 'phone: ',
|
||
'fax: ', and 'email: ', respectively. Phone numbers may contain
|
||
digits, whitespace and parentheses, which shall be ignored. Phone
|
||
numbers can also include one or more ASCII comma characters(hex
|
||
2C) to indicate a two-second pause during the dialing sequence.
|
||
If either the phone,fax, or email information is not available,
|
||
then a line should not included for this information.
|
||
NOTE: For interoperability purposes, it is advisable to use email
|
||
addresses formatted according to RFC 822 requirements.
|
||
Additional information:
|
||
The maximum supported string length is 28
|
||
characters.
|
||
|
||
If the user entered string is too long, the device will store
|
||
as much as possible and will return the
|
||
<noError> status."
|
||
::= { prtGeneralEntry 5 }
|
||
|
||
|
||
prtInputDefaultIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of prtInputIndex corresponding to the default input
|
||
sub-unit: that is, this object selects the default source of
|
||
input media.
|
||
This value shall be -1 if there is no default input subunit specified
|
||
for the printer as a whole. In this case, the actual default
|
||
input subunit may be specified by means outside the scope of this
|
||
MIB, such as by each interpreter in a printer with multiple
|
||
interpreters.
|
||
Additional information:
|
||
The default input tray is determined by the
|
||
printer based on DEFAULT-MEDIA-SIZE, what trays are locked
|
||
(if any), and whether or not Tray 2 is installed.
|
||
|
||
This object always returns -1, unknown."
|
||
::= { prtGeneralEntry 6 }
|
||
|
||
|
||
prtOutputDefaultIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of prtOutputIndex corresponding to the default
|
||
output sub-unit; that is, this object selects the default
|
||
output destination.
|
||
This value shall be -1 if there is no default output subunit specified
|
||
for the printer as a whole. In this case, the actual default
|
||
output subunit may be specified by means outside the scope of this
|
||
MIB, such as by each interpreter in a printer with multiple
|
||
interpreters.
|
||
Additional information:
|
||
The product has only one output bin, a
|
||
face-down bin located at the top of the printer."
|
||
::= { prtGeneralEntry 7 }
|
||
|
||
|
||
prtMarkerDefaultIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of prtMarkerIndex corresponding to the
|
||
default marker sub-unit; that is, this object selects the
|
||
default marker.
|
||
Additional information:
|
||
The product only has one marker subunit."
|
||
::= { prtGeneralEntry 8 }
|
||
|
||
|
||
prtMediaPathDefaultIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..3)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of prtMediaPathIndex corresponding to
|
||
the default media path; that is, the selection of the
|
||
default media path.
|
||
Additional information:
|
||
The only valid value for this object is 1
|
||
(simplex)."
|
||
::= { prtGeneralEntry 9 }
|
||
|
||
|
||
prtConsoleLocalization OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The value of the prtLocalizationIndex corresponding to
|
||
the language, country, and character set to be used for the
|
||
console. This localization applies both to the actual display
|
||
on the console as well as the encoding of these console
|
||
objects in management operations."
|
||
::= { prtGeneralEntry 10 }
|
||
|
||
|
||
prtConsoleNumberOfDisplayLines OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The number of lines on the printer's physical
|
||
display. This value is 0 if there are no lines on the
|
||
physical display or if there is no physical display."
|
||
::= { prtGeneralEntry 11 }
|
||
|
||
|
||
prtConsoleNumberOfDisplayChars OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The number of characters per line displayed on the physical
|
||
display. This value is 0 if there are no lines on the
|
||
physical display or if there is no physical display.
|
||
Additional information:
|
||
The device has a 16 character by 2 line display."
|
||
::= { prtGeneralEntry 12 }
|
||
|
||
|
||
prtConsoleDisable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePoperatorConsoleEnabled(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "If the object prtConsoleDisable has value
|
||
'operatorConsoleDisabled' then input is not accepted from the
|
||
operator console. If the object prtConsoleDisable has the value
|
||
'operatorConsoleEnabled' then input is accepted from the
|
||
operator console. If the object prtConsoleDisable has the value
|
||
'operatorConsoleEnabledLevel1','operatorConsoleEnabledLevel2' or
|
||
'operatorConsoleEnabledLevel3' then limited input is accepted
|
||
from the operator console; the limitations are product specific,
|
||
however, the limitations are generally less restrictive for
|
||
operatorConsoleEnabledLevel1 than for
|
||
operatorConsoleEnabledLeve2, which is less restrictive than
|
||
operatorConsoleEnabledLevel3.
|
||
The value of the prtConsoleDisable object is a type-2
|
||
enumeration."
|
||
::= { prtGeneralEntry 13 }
|
||
|
||
|
||
prtGeneralPrinterName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..32))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "An administrator-specified name for this printer.
|
||
Depending upon implementation of this printer, the value of this
|
||
object may or may not be same as the value for the MIB-II
|
||
'SysName' object.
|
||
Additional information:
|
||
The maximum supported string length is 32
|
||
characters. Length of 32 was chosen so a phone number could
|
||
be included with the name.
|
||
If the user-entered string is too long, the device will store
|
||
as much as possible and will return the
|
||
<noError> status. The value of this
|
||
object is saved over a power cycle."
|
||
::= { prtGeneralEntry 16 }
|
||
|
||
|
||
prtGeneralSerialNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..11))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "A recorded serial number for this device that indexes some type
|
||
device catalog or inventory. This value is usually set by the
|
||
device manufacturer but the MIB supports the option of
|
||
writeability for this object for site-specific administration of
|
||
device inventory or tracking."
|
||
::= { prtGeneralEntry 17 }
|
||
|
||
|
||
prtAlertCriticalEvents OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "A running counter of the number of critical alert events
|
||
that have been recorded in the alert table. The value of this
|
||
object is RESET in the event of a power cycle operation (i.e.,
|
||
the value is not persistent.
|
||
Additional information:
|
||
This object is set to zero every time the
|
||
printer is turned on."
|
||
::= { prtGeneralEntry 18 }
|
||
|
||
|
||
prtAlertAllEvents OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "A running counter of the total number of alert event entries
|
||
(critical and non-critical) that have been recorded in the
|
||
alert table
|
||
Additional information:
|
||
This object is set to zero every time the
|
||
printer is turned on. (It is not persistent through a
|
||
power-cycle.)"
|
||
::= { prtGeneralEntry 19 }
|
||
|
||
|
||
prtCoverDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The manufacturer provided cover sub-mechanism name in the
|
||
localization specified by prtGeneralCurrentLocalization."
|
||
::= { prtCoverEntry 2 }
|
||
|
||
|
||
prtCoverStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePdoorOpen(3),
|
||
ePdoorClosed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The status of this cover sub-unit."
|
||
::= { prtCoverEntry 3 }
|
||
|
||
|
||
prtLocalizationLanguage OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..2))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "A two character language code from ISO 639. Examples
|
||
en, gb, ca, fr, de."
|
||
::= { prtLocalizationEntry 2 }
|
||
|
||
|
||
prtLocalizationCountry OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..2))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "A two character country code from ISO 3166, a blank string
|
||
(two space characters) shall indicate that the country is
|
||
not defined. Examples: US, FR, DE, ..."
|
||
::= { prtLocalizationEntry 3 }
|
||
|
||
|
||
prtLocalizationCharacterSet OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePcsHPRoman8(2004),
|
||
ePcsISOLatin2(5),
|
||
ePcsISOLatinCyrillic(8),
|
||
ePcsISOLatin5(12),
|
||
ePcsISOLatinGreek(10),
|
||
ePcsISOLatinHebrew(11),
|
||
ePcsISOLatinArabic(9),
|
||
ePcsUnicode(2000)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The coded character set used for this localization."
|
||
::= { prtLocalizationEntry 4 }
|
||
|
||
|
||
prtStorageRefIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of the hrDeviceIndex of the printer device that this
|
||
storageEntry is associated with."
|
||
::= { prtStorageRefEntry 2 }
|
||
|
||
|
||
prtDeviceRefIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(1..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of the hrDeviceIndex of the printer device that this
|
||
deviceEntry is associated with."
|
||
::= { prtDeviceRefEntry 2 }
|
||
|
||
|
||
prtInputType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePsheetFeedAutoRemovableTray(3),
|
||
ePsheetFeedAutoNonRemovableTray(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The type of technology (discriminated primarily according to
|
||
feeder mechanism type) employed by the input sub-unit. Note,
|
||
the Optional Input Class provides for a descriptor field to
|
||
further qualify the other choice.
|
||
Additional information:
|
||
Tray 1 is the multi-purpose tray and is always
|
||
present. It supports both sheets and envelopes. Its type is
|
||
ePsheetFeedAutoNonRemovableTray. The tray 2 object does not
|
||
exist when the tray is NOT installed."
|
||
::= { prtInputEntry 2 }
|
||
|
||
|
||
prtInputDimUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The unit of measurement for use calculating and relaying
|
||
dimensional values for this input sub-unit.
|
||
Additional information:
|
||
Following is a table of paper sizes and
|
||
dimensions for each paper size supported by
|
||
the product:
|
||
|
||
Size....................Inches(ten-thousandths)...Micrometers
|
||
-----------------------------------------------------------------
|
||
eUSExecutive............72500 x 105000............184150 x 266700
|
||
eUSLetter...............85000 x 110000............215900 x 279400
|
||
eUSLegal................85000 x 140000............215900 x 355600
|
||
eFoolscap...............85000 x 130000............215900 x 330200
|
||
eROC16K.................77500 x 107500............196850 x 273050
|
||
eISOandJISA4............82677 x 116929............210000 x 297000
|
||
eISOandJISA5............58286 x 82677.............148000 x 210000
|
||
eJISB5..................71654 x 101181............182000 x 257000
|
||
eIOSB5..................69300 x 98400.............176000 x 250000
|
||
eJapanesePostcardSingle.39370 x 58267.............100000 x 148000
|
||
eJapanesePostcardDouble.58267 x 78740.............148000 x 200000
|
||
eMonarch................38750 x 75000.............98425 x 190500
|
||
eCommercial10...........41250 x 95000.............104775 x 241300
|
||
eInternationalDL........43307 x 86614.............110000 x 220000
|
||
eInternationalC5........63780 x 90157.............162000 x 229000
|
||
eInternationalB5........69291 x 98425.............176000 x 250000
|
||
eCustom.................30000 x 140000(max).......76000 x 355600(max)"
|
||
::= { prtInputEntry 3 }
|
||
|
||
|
||
prtInputMediaDimFeedDirDeclared OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object provides the value of the declared dimension, in
|
||
the feed direction, of the media that is (or, if empty, was or
|
||
will be) in this input sub-unit. The feed direction is the
|
||
direction in which the media is fed on this sub-unit. This
|
||
dimension is measured in input sub-unit dimensional units
|
||
(prtInputDimUnit). If this input sub-unit can reliably sense
|
||
this value, the value is sensed by the printer and may not be
|
||
changed by management requests. Otherwise, the value may be
|
||
changed. The value (-1) means other and specifically means
|
||
that this sub-unit places no restriction on this parameter.
|
||
The value (-2) indicates unknown.
|
||
Additional information:
|
||
The default values assume the trays are
|
||
configured for letter size paper. For tray 1 the value is
|
||
the dimension for the media size currently declared.
|
||
|
||
Valid values are 50000 to 140000 if prtInputDimUnit is
|
||
ePtenThousandthsOfInches and 127000 to 355600 if
|
||
prtInputDimUnit is ePmicrometers."
|
||
::= { prtInputEntry 4 }
|
||
|
||
|
||
prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object provides the value of the declared dimension, in
|
||
the cross feed direction, of the media that is (or, if empty,
|
||
was or will be) in this input sub-unit. The cross feed
|
||
direction is ninety degrees relative to the feed direction
|
||
associated with this sub-unit. This dimension is measured in
|
||
input sub-unit dimensional units (prtInputDimUnit). If this
|
||
input sub-unit can reliably sense this value, the value is
|
||
sensed by the printer and may not be changed by management
|
||
requests. Otherwise, the value may be changed. The value (-1)
|
||
means other and specifically means that this sub-unit places
|
||
no restriction on this parameter. The value (-2) indicates
|
||
unknown.
|
||
Additional information:
|
||
The default values assume the trays are
|
||
configured for letter size paper. For trays 1 & 2, the value
|
||
is the dimension for the media size currently declared.
|
||
|
||
Valid values are 30000 to 85000 if prtInputDimUnit is
|
||
ePtenThousandthsOfInches and 76000 to 216000 if
|
||
prtInputDimUnit is ePmicrometers. The minimum
|
||
value for tray 2 is 72500 (tenthousandsinch)
|
||
and 191000(micrometers)."
|
||
::= { prtInputEntry 5 }
|
||
|
||
|
||
prtInputMediaDimFeedDirChosen OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The printer will act as if media of the chosen dimension (in
|
||
the feed direction) is present in this input source. Note
|
||
that this value will be used even if the input tray is empty.
|
||
Feed dimension measurements are taken relative to the feed
|
||
direction associated with that sub-unit and are in input sub-unit
|
||
dimensional units (MediaUnit). If the printer supports the
|
||
declared dimension, the granted dimension is the same as
|
||
the declared dimension. If not, the granted dimension is
|
||
set to the closest dimension that the printer supports
|
||
when the declared dimension is set. The value (-1) means
|
||
other and specifically indicates that this sub-unit
|
||
places no restriction on this parameter. The value (-2)
|
||
indicates unknown.
|
||
Additional information:
|
||
The default value assumes the trays are configured
|
||
for letter size paper. The objects for the trays
|
||
return the value of the media size for which the trays
|
||
are currently configured because it cannot sense what size
|
||
media they contain."
|
||
::= { prtInputEntry 6 }
|
||
|
||
|
||
prtInputMediaDimXFeedDirChosen OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The printer will act as if media of the chosen dimension (in
|
||
the cross feed direction) is present in this input source.
|
||
Note that this value will be used even if the input tray is
|
||
empty. The cross feed direction is ninety degrees relative
|
||
to the feed direction associated with this sub-unit. This
|
||
dimension is measured in input sub-unit dimensional units
|
||
(MediaUnit). If the printer supports the declared
|
||
dimension, the granted dimension is the same as the
|
||
declared dimension. If not, the granted dimension is set
|
||
to the closest dimension that the printer supports when
|
||
the declared dimension is set. The value (-1) means other
|
||
and specifically indicates that this sub-unit places no
|
||
restriction on this parameter. The value (-2) indicates
|
||
unknown.
|
||
Additional information:
|
||
The default value assumes the trays are configured
|
||
for letter size paper. The object for the trays
|
||
return the value of the media size for which the trays
|
||
are currently configured because it cannot sense what size
|
||
media it contains."
|
||
::= { prtInputEntry 7 }
|
||
|
||
|
||
prtInputCapacityUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePsheets(8)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The unit of measurement for use in calculating and relaying
|
||
capacity values for this input sub-unit.
|
||
Additional information:
|
||
A sheet is a single piece of 20 pound paper. "
|
||
::= { prtInputEntry 8 }
|
||
|
||
|
||
prtInputMaxCapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum capacity of the input sub-unit in input
|
||
sub-unit capacity units (PrtCapacityUnitTC). There is no
|
||
convention associated with the media itself so this value
|
||
reflects claimed capacity. If this input sub-unit can
|
||
reliably sense this value, the value is sensed by the
|
||
printer and may not be changed by management requests;
|
||
otherwise, the value may be written (by a Remote
|
||
Control Panel or a Management Application).
|
||
The value (-1) means other and specifically
|
||
indicates that the sub-unit places no restrictions
|
||
on this parameter. The value (-2) means unknown.
|
||
Additional information:
|
||
This is specified assuming 20 pound paper for
|
||
the paper trays and that the device is a Raptor. Kiwi only
|
||
has tray 1 and its DEFAULT value is 150"
|
||
::= { prtInputEntry 9 }
|
||
|
||
|
||
prtInputCurrentLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The current capacity of the input sub-unit in input
|
||
sub-unit capacity units (PrtCapacityUnitTC). If this input
|
||
sub-unit can reliably sense this value, the value is
|
||
sensed by the printer and may not be changed by
|
||
management requests; otherwise, the value may
|
||
be written (by a Remote Contol Panel or a
|
||
Management Application). The value (-1) means other and
|
||
specifically indicates that the sub-unit places no
|
||
restrictions on this parameter. The value (-2) means unknown.
|
||
The value (-3) means that the printer knows that at least one
|
||
unit remains.
|
||
Additional information:
|
||
The product can only detect
|
||
empty/not empty in its trays. It returns -3 for not empty
|
||
and -2 (unknown) for any other condition (e.g. tray is empty
|
||
or tray is removed)."
|
||
::= { prtInputEntry 10 }
|
||
|
||
|
||
prtInputStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The current status of this input sub-unit.
|
||
Additional information:
|
||
The default value assumes that media is loaded
|
||
in the tray. When there is not media loaded in the tray it
|
||
returns 9 instead of 0 (the default).
|
||
|
||
Default - 0 (Available and Idle)
|
||
paper motion - 6 (Available and Busy)
|
||
paper out in this tray - 9 (Non-Critical Alert(8) + Unavailable and OnRequest(1))
|
||
paper mount in this tray - 48 (Critical Alert (16) + OffLine (32))
|
||
manual feed prompt (PaperMount) - 48 (Critical Alert (16) + OffLine (32))"
|
||
::= { prtInputEntry 11 }
|
||
|
||
|
||
prtInputMediaName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "A description of the media contained in this input sub-unit;
|
||
This description is intended for display to a human operator.
|
||
This description is not processed by the printer. It is used
|
||
to provide information not expressible in terms of the other
|
||
media attributes (e.g. prtInputMediaDimFeedDirChosen,
|
||
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
|
||
prtInputMediaType). An example would be `legal tender bond
|
||
paper'.
|
||
Additional information:
|
||
The product supports the
|
||
concept of named media types. The values for this
|
||
object will always match one of the MEDIAn-NAME objects."
|
||
::= { prtInputEntry 12 }
|
||
|
||
|
||
prtInputName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The name assigned to this input sub-unit."
|
||
::= { prtInputEntry 13 }
|
||
|
||
|
||
prtInputVendorName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The vendor name of this input sub-unit."
|
||
::= { prtInputEntry 14 }
|
||
|
||
|
||
prtInputModel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The model name of this input sub-unit.
|
||
Additional information:
|
||
The product does not specify model
|
||
names for the input trays."
|
||
::= { prtInputEntry 15 }
|
||
|
||
|
||
prtInputVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The version of this input sub-unit.
|
||
Additional information:
|
||
The product does not specify version
|
||
numbers for the input trays."
|
||
::= { prtInputEntry 16 }
|
||
|
||
|
||
prtInputSerialNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..63))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The serial number assigned to this input sub-unit.
|
||
Additional information:
|
||
The product does not specify serial
|
||
numbers for the input trays."
|
||
::= { prtInputEntry 17 }
|
||
|
||
|
||
prtInputDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "A free-form text description of this input
|
||
sub-unit in the localization specified by
|
||
prtGeneralCurrentLocalization."
|
||
::= { prtInputEntry 18 }
|
||
|
||
|
||
prtInputSecurity OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePon(3),
|
||
ePoff(4),
|
||
ePnotPresent(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates if this input sub-unit has some security
|
||
associated with it.
|
||
Additional information:
|
||
No security mechanism provided."
|
||
::= { prtInputEntry 19 }
|
||
|
||
|
||
prtOutputType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePunknown(2),
|
||
ePremovableBin(3),
|
||
ePunRemovableBin(4),
|
||
ePcontinuousRollDevice(5),
|
||
ePmailBox(6),
|
||
ePcontinousFanFold(7)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The type of technology supported by this output sub-unit.
|
||
Additional information:
|
||
The product has only one output bin, a
|
||
face-down bin located at the top of the printer."
|
||
::= { prtOutputEntry 2 }
|
||
|
||
|
||
prtOutputCapacityUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4),
|
||
ePsheets(8),
|
||
ePfeet(16),
|
||
ePmeters(17)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The unit of measurement for use in calculating and relaying
|
||
capacity values for this output sub-unit.
|
||
Additional information:
|
||
A sheet is a single piece of 20 pound paper."
|
||
::= { prtOutputEntry 3 }
|
||
|
||
|
||
prtOutputMaxCapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum capacity of this output sub-unit in output
|
||
sub-unit capacity units (PrtCapacityUnitTC). There is no
|
||
convention associated with the media itself so this value
|
||
essentially reflects claimed capacity. If this output
|
||
sub-unit can reliably sense this value, the value is
|
||
sensed by the printer and may not be changed by management
|
||
requests; otherwise, the value may be written
|
||
(by a Remote Control Panel or a Management Application).
|
||
The value (-1) means other and specifically indicates
|
||
that the sub-unit places no restrictions on this parameter.
|
||
The value (-2) means unknown.
|
||
Additional information:
|
||
Note: The product cannot sense how
|
||
much is in the output bin. The output bin can hold 125
|
||
sheets."
|
||
::= { prtOutputEntry 4 }
|
||
|
||
|
||
prtOutputRemainingCapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The remaining capacity of the possible output sub-unit
|
||
capacity in output sub-unit capacity units (PrtCapacityUnitTC)
|
||
of this output sub-unit. If this output sub-unit can
|
||
reliably sense this value, the value is sensed by the
|
||
printer and may not be modified by management requests;
|
||
otherwise, the value may be written (by
|
||
a Remote Control Panel or a Management
|
||
Application). The value (-1) means other and
|
||
specifically indicates that the sub-unit places no
|
||
restrictions on this parameter. The value (-2) means
|
||
unknown. The value (-3) means that the printer knows that
|
||
there remains capacity for at least one unit.
|
||
Additional information:
|
||
The product does not have any sensing
|
||
on the output bin, so it will always report unknown (-2).
|
||
Note that for the products, this object is read-only
|
||
because any values written by a Remote Control Panel or a
|
||
Management Application would be unreliable."
|
||
::= { prtOutputEntry 5 }
|
||
|
||
|
||
prtOutputStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The current status of this output sub-unit.
|
||
Additional information:
|
||
The product cannot sense the output
|
||
tray so this object will always return 5 (Unknown Status)."
|
||
::= { prtOutputEntry 6 }
|
||
|
||
|
||
prtMarkerMarkTech OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePelectrophotographicLaser(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The type of marking technology used for this marking sub-unit."
|
||
::= { prtMarkerEntry 2 }
|
||
|
||
|
||
prtMarkerCounterUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePimpressions(7)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The unit that will be used by the printer when reporting
|
||
counter values for this marking sub-unit. The
|
||
time units of measure are provided for a device like a
|
||
strip recorder that does not or cannot track the physical
|
||
dimensions of the media and does not use characters,
|
||
lines or sheets.
|
||
Additional information:
|
||
Since the product keeps track of pages
|
||
printed, the counter unit will be defined as ePimpressions
|
||
which would be like saying pages printed. (The term
|
||
'impressions' is used instead of 'pages' to avoid confusion
|
||
between 'sheets' and 'pages' on a duplexing printer.)"
|
||
::= { prtMarkerEntry 3 }
|
||
|
||
|
||
prtMarkerLifeCount OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The count of the number of units of measure counted during
|
||
the life of printer using units of measure as specified by
|
||
prtMarkerCounterUnit.
|
||
Additional information:
|
||
In the product, the total engine page
|
||
count is kept in NVRAM, however the NVRAM value is only
|
||
updated every 10 impressions.
|
||
|
||
NOTE: The value returned by this OID will be incremented
|
||
every page but if power is lost between NVRAM updates, up to
|
||
9 impressions of the page count may be lost. The counter
|
||
will be reset to zero after 999999 pages.
|
||
|
||
The page count is incremented when a sheet of media is pulled
|
||
from an input tray."
|
||
::= { prtMarkerEntry 4 }
|
||
|
||
|
||
prtMarkerPowerOnCount OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The count of the number of units of measure counted since the
|
||
equipment was most recently powered on using units of measure as
|
||
specified by prtMarkerCounterUnit."
|
||
::= { prtMarkerEntry 5 }
|
||
|
||
|
||
prtMarkerProcessColorants OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The number of process colors supported by this marker. A
|
||
process color of 1 implies monochrome. The value of this
|
||
object and prtMarkerSpotColorants cannot both be 0. The value of
|
||
prtMarkerProcessColorants must be 0 or greater."
|
||
::= { prtMarkerEntry 6 }
|
||
|
||
|
||
prtMarkerSpotColorants OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The number of spot colors supported by this marker. The
|
||
value of this object and prtMarkerProcessColorants cannot
|
||
both be 0. Must be 0 or greater."
|
||
::= { prtMarkerEntry 7 }
|
||
|
||
|
||
prtMarkerAddressabilityUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The unit of measure of distances, as applied to the marker's
|
||
resolution.
|
||
Additional information:
|
||
This will always be ePtenThousandthsOfInches, no
|
||
matter what COLD-RESET-MEDIA-SIZE is because we are talking
|
||
about resolution and toner addressability, which is always
|
||
dpi."
|
||
::= { prtMarkerEntry 8 }
|
||
|
||
|
||
prtMarkerAddressabilityFeedDir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum number of addressable marking positions in the feed
|
||
direction per 10000 units of measure specified by
|
||
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
|
||
'infinite' while a value of (-2) implies 'unknown'.
|
||
Additional information:
|
||
Use this object to specify resolution. The
|
||
product supports 300, 600, or 1200 dots
|
||
per inch with 600 being the default."
|
||
::= { prtMarkerEntry 9 }
|
||
|
||
|
||
prtMarkerAddressabilityXFeedDir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum number of addressable marking positions in the cross
|
||
feed direction in 10000 units of measure specified by
|
||
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
|
||
'infinite' while a value of (-2) implies 'unknown'.
|
||
Additional information:
|
||
Use this object to specify resolution. The
|
||
product support 300, 600, or 1200 dots per inch with
|
||
1200 being the default."
|
||
::= { prtMarkerEntry 10 }
|
||
|
||
|
||
prtMarkerNorthMargin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The margin, in units identified by prtMarkerAddressabilityUnit,
|
||
from the leading edge of the medium as the medium flows
|
||
through the marking engine with the side to be imaged
|
||
facing the observer. The leading edge is the North edge
|
||
and the other edges are defined by the normal compass
|
||
layout of directions with the compass facing the
|
||
observer. Printing within the area bounded by all four
|
||
margins is guaranteed for all interpreters. The value
|
||
(-2) means unknown."
|
||
::= { prtMarkerEntry 11 }
|
||
|
||
|
||
prtMarkerSouthMargin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The margin from the South edge (see prtMarkerNorthMargin)
|
||
of the medium in units identified by
|
||
prtMarkerAddressabilityUnit. Printing within the area bounded by
|
||
all four margins is guaranteed for all interpreters.
|
||
The value (-2) means unknown."
|
||
::= { prtMarkerEntry 12 }
|
||
|
||
|
||
prtMarkerWestMargin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The margin from the West edge (see prtMarkerNorthMargin) of the
|
||
medium in units identified by prtMarkerAddressabilityUnit.
|
||
Printing within the area bounded by all four margins is
|
||
guaranteed for all interpreters. The value (-2) means
|
||
unknown."
|
||
::= { prtMarkerEntry 13 }
|
||
|
||
|
||
prtMarkerEastMargin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The margin from the East edge (see prtMarkerNorthMargin) of the
|
||
medium in units identified by prtMarkerAddressabilityUnit.
|
||
Printing within the area bounded by all four margins is
|
||
guaranteed for all interpreters. The value (-2) means
|
||
unknown."
|
||
::= { prtMarkerEntry 14 }
|
||
|
||
|
||
prtMarkerStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The current status of this marker sub-unit.
|
||
Additional information:
|
||
The default value assumes the printer is idle
|
||
and has no malfunctions.
|
||
|
||
Default - 0 (Available and Idle)
|
||
no toner cartridge - 51 (UnAvailable because Broken (3) + Critical Alert (16) + OffLine (32))"
|
||
::= { prtMarkerEntry 15 }
|
||
|
||
|
||
prtMarkerSuppliesMarkerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of prtMarkerIndex corresponding to the
|
||
marking sub-unit with which this marker supply
|
||
sub-unit is associated."
|
||
::= { prtMarkerSuppliesEntry 2 }
|
||
|
||
|
||
prtMarkerSuppliesColorantIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of prtMarkerColorantIndex
|
||
corresponding to the colorant with which this
|
||
marker supply sub-unit is associated. This value
|
||
shall be 0 if there is no colorant table."
|
||
::= { prtMarkerSuppliesEntry 3 }
|
||
|
||
|
||
prtMarkerSuppliesClass OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePsupplyThatIsConsumed(3),
|
||
ePreceptacleThatIsFilled(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates whether this supply entity represents a supply
|
||
that is consumed or a receptacle that is filled."
|
||
::= { prtMarkerSuppliesEntry 4 }
|
||
|
||
|
||
prtMarkerSuppliesType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtoner(3),
|
||
ePtransferUnit(20),
|
||
ePtonerCartridge(21),
|
||
ePfuser(15),
|
||
ePdeveloper(10),
|
||
ePfuserCleaingPad(19),
|
||
ePopc(9)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The type of this supply."
|
||
::= { prtMarkerSuppliesEntry 5 }
|
||
|
||
|
||
prtMarkerSuppliesDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The description of this supply container/receptacle in the
|
||
localization specified by prtGeneralCurrentLocalization."
|
||
::= { prtMarkerSuppliesEntry 6 }
|
||
|
||
|
||
prtMarkerSuppliesSupplyUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4),
|
||
ePimpressions(7),
|
||
ePsheets(8),
|
||
ePthousandthsOfOunces(12),
|
||
ePhours(11),
|
||
ePtenthsOfGrams(13),
|
||
ePhundrethsOfFluidOunces(14),
|
||
ePtenthsOfMilliliters(15),
|
||
ePfeet(16),
|
||
ePmeters(17),
|
||
ePpercent(19)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Unit of measure of this marker supply container/receptacle."
|
||
::= { prtMarkerSuppliesEntry 7 }
|
||
|
||
|
||
prtMarkerSuppliesMaxCapacity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum capacity of this supply container/receptacle
|
||
expressed in prtMarkerSuppliesSupplyUnit. If this supply
|
||
container/receptacle can reliably sense this value, the
|
||
value is reported by the printer and is read-only;
|
||
otherwise, the value may be written (by a Remote Control
|
||
Panel or a Management Application). The value (-1) means
|
||
other and specifically indicates that the sub-unit places
|
||
no restrictions on this parameter. The value (-2) means
|
||
unknown.
|
||
Additional information:
|
||
This object reports the maximum capacity for the supply
|
||
against which the level is reported."
|
||
::= { prtMarkerSuppliesEntry 8 }
|
||
|
||
|
||
prtMarkerSuppliesLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The current level if this supply is a container; the
|
||
remaining space if this supply is a receptacle. If this
|
||
supply container/receptacle can reliably sense this
|
||
value, the value is reported by the printer and is
|
||
read-only; otherwise, the value may be written (by a
|
||
Remote Control Panel or a Management Application). The
|
||
value (-1) means other and specifically indicates that
|
||
the sub-unit places no restrictions on this parameter.
|
||
The value (-2) means unknown. A value of (-3) means that the
|
||
printer knows that there is some supply/remaining space,
|
||
respectively.
|
||
Additional information:
|
||
Print Cartridges measure life based on the three
|
||
components: toner, developer and drum. These Print
|
||
Cartridge objects (1..4) report the lowest of these
|
||
three factors. Print Cartridges that are not
|
||
installed will return a value of 100."
|
||
::= { prtMarkerSuppliesEntry 9 }
|
||
|
||
|
||
prtMarkerColorantMarkerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..65535)
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The value of prtMarkerIndex corresponding to the
|
||
marker sub-unit with which this colorant entry is
|
||
associated."
|
||
::= { prtMarkerColorantEntry 2 }
|
||
|
||
|
||
prtMarkerColorantRole OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePprocess(3),
|
||
ePspot(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The role played by this colorant."
|
||
::= { prtMarkerColorantEntry 3 }
|
||
|
||
|
||
prtMarkerColorantValue OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The name of the color of this
|
||
colorant using standardized string names from ISO 10175 (DPA)
|
||
and ISO 10180 (SPDL) which are:
|
||
other
|
||
unknown
|
||
white
|
||
red
|
||
green
|
||
blue
|
||
cyan
|
||
magenta
|
||
yellow
|
||
black
|
||
Implementors may add additional string values. The naming
|
||
conventions in ISO 9070 are recommended in order to avoid
|
||
potential name clashes.
|
||
Additional information:
|
||
"
|
||
::= { prtMarkerColorantEntry 4 }
|
||
|
||
|
||
prtMarkerColorantTonality OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The distinct levels of tonality realizable by a marking
|
||
sub-unit when using this colorant. This value does not
|
||
include the number of levels of tonal difference that an
|
||
interpreter can obtain by techniques such as half toning.
|
||
This value must be at least 2."
|
||
::= { prtMarkerColorantEntry 5 }
|
||
|
||
|
||
prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePimpressionsPerHour(7)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The unit of measure used in specifying the speed of all media
|
||
paths in the printer.
|
||
Additional information:
|
||
ePimpressionsPerHour is the value that will
|
||
always be returned for this object. (Print Speed is measured
|
||
in pages-per-minute (impressions per minute), so
|
||
ePimpressionsPerHour is a natural extension.)"
|
||
::= { prtMediaPathEntry 2 }
|
||
|
||
|
||
prtMediaPathMediaSizeUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePtenThousandthsOfInches(3),
|
||
ePmicrometers(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The units of measure of media size for use in calculating and
|
||
relaying dimensional values for all media paths in the printer."
|
||
::= { prtMediaPathEntry 3 }
|
||
|
||
|
||
prtMediaPathMaxSpeed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum printing speed of this media path expressed in
|
||
prtMediaPathMaxSpeedUnit's. A value of (-1) implies
|
||
'other'.
|
||
Additional information:
|
||
The page size for this performance is 8.5 x 11. For
|
||
Kiwi, this value is (12ppm * 60). For Raptor, this value is
|
||
1260 (21ppm * 60)"
|
||
::= { prtMediaPathEntry 4 }
|
||
|
||
|
||
prtMediaPathMaxMediaFeedDir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum physical media size in the feed direction of this
|
||
media path expressed in units of measure specified by
|
||
PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited',
|
||
a value of (-2) implies 'unknown'.
|
||
Additional information:
|
||
The value returned by this object depends on the
|
||
value of prtMediaPathMediaSizeUnit. It is 140000 if
|
||
prtInputDimUnit is ePtenThousandthsOfInches or 355600 if
|
||
prtInputDimUnit is ePmicrometers. (140000 is the value
|
||
arrived at because legal paper is the longest allowable on
|
||
the product.)"
|
||
::= { prtMediaPathEntry 5 }
|
||
|
||
|
||
prtMediaPathMaxMediaXFeedDir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum physical media size across the feed direction of
|
||
this media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
Additional information:
|
||
The value returned by this object depends on the
|
||
value of prtMediaPathMediaSizeUnit. It is 85000 if
|
||
prtInputDimUnit is ePtenThousandthsOfInches or 216000 if
|
||
prtInputDimUnit is ePmicrometers."
|
||
::= { prtMediaPathEntry 6 }
|
||
|
||
|
||
prtMediaPathMinMediaFeedDir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The minimum physical media size in the feed direction of this
|
||
media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
Additional information:
|
||
The value returned by this object depends on the
|
||
value of prtMediaPathMediaSizeUnit. It is 50000 if
|
||
prtInputDimUnit is ePtenThousandthsOfInches or 127000 if
|
||
prtInputDimUnit is ePmicrometers."
|
||
::= { prtMediaPathEntry 7 }
|
||
|
||
|
||
prtMediaPathMinMediaXFeedDir OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The minimum physical media size across the feed direction of
|
||
this media path expressed in units of measure specified by
|
||
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
Additional information:
|
||
The value returned by this object depends on the
|
||
value of prtMediaPathMediaSizeUnit. It is 30000 if
|
||
prtInputDimUnit is ePtenThousandthsOfInches or 76200 if
|
||
prtInputDimUnit is ePmicrometers. This size corresponds to a
|
||
Monarch envelope. "
|
||
::= { prtMediaPathEntry 8 }
|
||
|
||
|
||
prtMediaPathType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePsimplex(5)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The type of the media path for this media path.
|
||
Additional information:
|
||
This object describes how many paths there are
|
||
through the engine disregarding the paper source (tray 1, 2,
|
||
or 3)."
|
||
::= { prtMediaPathEntry 9 }
|
||
|
||
|
||
prtMediaPathDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The manufacturer-provided description of this media path in
|
||
the localization specified by prtGeneralCurrentLocalization."
|
||
::= { prtMediaPathEntry 10 }
|
||
|
||
|
||
prtMediaPathStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The current status of this media path.
|
||
Additional information:
|
||
The default values assume the printer is idle.
|
||
|
||
Default - 0 (Available and Idle)
|
||
paper motion - 6 (Available and Busy)
|
||
paper out in all trays - 9 (Non-Critical Alert(8) + Unavailable and OnRequest(1))
|
||
paper mount (any tray) - 0 (Available and Idle)
|
||
manual feed prompt (PaperMount) - 48 (Critical Alert (16) + OffLine (32))"
|
||
::= { prtMediaPathEntry 11 }
|
||
|
||
|
||
prtInterpreterLangFamily OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePlangPCL(3),
|
||
ePlangPJL(5),
|
||
ePlangPS(6),
|
||
ePlangAutomatic(37),
|
||
ePlangPCLXL(47)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The family name of a Page Description Language (PDL) or
|
||
control language which this interpreter in the printer can
|
||
interpret or emulate.
|
||
Additional information:
|
||
ePlangAutomatic refers to the 'super-language'
|
||
made available by implicit language switching."
|
||
::= { prtInterpreterEntry 2 }
|
||
|
||
|
||
prtInterpreterLangLevel OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The level of the language which this interpreter is
|
||
interpreting or emulating. This might contain a value like
|
||
'5e' for an interpreter which is emulating level 5e of the PCL
|
||
language. It might contain '2' for an interpreter which is
|
||
emulating level 2 of the PostScript language. Similarly it
|
||
might contain '2' for an interpreter which is emulating level
|
||
2 of the HPGL language."
|
||
::= { prtInterpreterEntry 3 }
|
||
|
||
|
||
prtInterpreterLangVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The date code or version of the language which this interpreter
|
||
is interpreting or emulating.
|
||
Additional information:
|
||
These values are derived from the dateCode field
|
||
of the personality entities. (ePlangautomatic uses the PJL
|
||
dateCode.) For PostScript, this is more detailed revision
|
||
information."
|
||
::= { prtInterpreterEntry 4 }
|
||
|
||
|
||
prtInterpreterDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "A string to identify this interpreter in the localization
|
||
specified by prtGeneralCurrentLocalization as opposed to the
|
||
language which is being interpreted. It is anticipated that
|
||
this string will allow manufacturers to unambiguously identify
|
||
their interpreters.
|
||
Additional information:
|
||
None of these strings are localized."
|
||
::= { prtInterpreterEntry 5 }
|
||
|
||
|
||
prtInterpreterVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..31))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The date code, version number, or other product specific
|
||
information tied to this interpreter. This value is
|
||
associated with the interpreter, rather than with the version
|
||
of the language which is being interpreted or emulated.
|
||
Additional information:
|
||
Same as prtInterpreterLangVersion."
|
||
::= { prtInterpreterEntry 6 }
|
||
|
||
|
||
prtInterpreterDefaultOrientation OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePportrait(3),
|
||
ePlandscape(4)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The current orientation default for this interpreter. This
|
||
value may be overridden for a particular job (e.g., by a
|
||
command in the input data stream).
|
||
Additional information:
|
||
Interpreters 1 and 2 ignore the value of this
|
||
object.
|
||
|
||
The values for PCL and PostScript are either ePportrait or
|
||
ePlandscape; attempting to set them to a different value will
|
||
cause <badValue> to be returned.
|
||
Setting this object for one interpreter will change it for
|
||
all installed interpreters."
|
||
::= { prtInterpreterEntry 7 }
|
||
|
||
|
||
prtInterpreterFeedAddressability OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum interpreter addressability in the feed
|
||
direction in 10000 prtMarkerAddressabilityUnits (see
|
||
prtMarkerAddressabilityFeedDir ) for this interpreter.
|
||
The value (-1) means other and specifically indicates
|
||
that the sub-unit places no restrictions on this parameter."
|
||
::= { prtInterpreterEntry 8 }
|
||
|
||
|
||
prtInterpreterXFeedAddressability OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The maximum interpreter addressability in the cross feed
|
||
direction in 10000 prtMarkerAddressabilityUnits (see
|
||
prtMarkerAddressabilityXFeedDir) for this interpreter.
|
||
The value (-1) means other and specifically indicates
|
||
that the sub-unit places no restrictions on this
|
||
parameter."
|
||
::= { prtInterpreterEntry 9 }
|
||
|
||
|
||
prtInterpreterDefaultCharSetIn OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePcsASCII(3),
|
||
ePcsISOLatin1(4),
|
||
ePcsISOLatin2(5),
|
||
ePcsISOLatin5(12),
|
||
ePcsISOLatin6(13),
|
||
ePcsISOLatin9(2090),
|
||
ePcsISO4UnitedKingdom(20),
|
||
ePcsISO11SwedishforNames(21),
|
||
ePcsISO15Italian(22),
|
||
ePcsISO17Spanish(23),
|
||
ePcsISO21German(24),
|
||
ePcsISO60DanishNorwegian(25),
|
||
ePcsISO69French(26),
|
||
ePcsUnicodeIBM2039(1004),
|
||
ePcsWindows30Latin1(2000),
|
||
ePcsWindows31Latin1(2001),
|
||
ePcsWindows31Latin2(2002),
|
||
ePcsWindows31Latin5(2003),
|
||
ePcsHPRoman8(2004),
|
||
ePcsAdobeStandardEncoding(2005),
|
||
ePcsPC850Multilingual(2009),
|
||
ePcsPC858Multilingual(2089),
|
||
ePcsPCp852(2010),
|
||
ePcsPC8CodePage437(2011),
|
||
ePcsPC8DNDanishNorwegian(2012),
|
||
ePcsHPPC8Turkish(2014),
|
||
ePcsHPLegal(2017),
|
||
ePcsHPDeskTop(2021),
|
||
ePcsMacintosh(2027),
|
||
ePcsPC77Baltic(2087),
|
||
ePcsWindows1257Baltic(2257)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION "The default coded character set for input octets
|
||
encountered outside a context in which the Page
|
||
Description Language established the interpretation
|
||
of the octets. (Input octets are presented to the
|
||
interpreter through a path defined in the channel group.)
|
||
This value shall be (2) if there is no default.
|
||
Additional information:
|
||
ePcsAdobeStandardEncoding is the same as PSText(10J).
|
||
|
||
The object corresponding to PCL has read-write access;
|
||
all others are read-only.
|
||
|
||
Note: To determine which languages correspond to which subarrays refer
|
||
to the object prtInterpreterLangFamily.
|
||
|
||
The above list corresponds to the following symbol sets as they appear
|
||
on the Control Panel:
|
||
|
||
ePother( 1) - used if designated coded char. set not in list
|
||
ePcsASCII( 3) - ISO-6
|
||
ePcsISOLatin1( 4) - ISO L1
|
||
ePcsISOLatin2( 5) - IS L2
|
||
ePcsISOLatin5( 12) - ISO L5
|
||
ePcsISOLatin6( 13) - ISO L6
|
||
ePcsISOLatin9( 2090) - ISO L9
|
||
ePcsISO4UnitedKingdom( 20) - ISO-4
|
||
ePcsISO11SwedishforNames( 21) - ISO-11
|
||
ePcsISO15Italian( 22) - ISO-15
|
||
ePcsISO17Spanish( 23) - ISO-17
|
||
ePcsISO21German( 24) - ISO-21
|
||
ePcsISO60DanishNorwegian( 25) - ISO-60
|
||
ePcsISO69French( 26) - ISO-69
|
||
ePcsUnicodeIBM2039(1004) - PC-1004
|
||
ePcsWindows30Latin1( 2000) - WIN 3.0
|
||
ePcsWindows31Latin1( 2001) - WIN L1
|
||
ePcsWindows31Latin2( 2002) - WIN L2
|
||
ePcsWindows31Latin5( 2003) - WIN L5
|
||
ePcsHPRoman8( 2004) - ROMAN-8
|
||
ePcsAdobeStandardEncoding( 2005) - PS TEXT
|
||
ePcsPC850Multilingual( 2009) - PC-850
|
||
ePcsPC858Multilingual( 2089) - PC-858
|
||
ePcsPCp852( 2010) - PC-852
|
||
ePcsPC8CodePage437( 2011) - PC-8
|
||
ePcsPC8DNDanishNorwegian( 2012) - PC-8DN
|
||
ePcsHPPC8Turkish( 2014) - PC-8 TK
|
||
ePcsHPLegal( 2017) - LEGAL
|
||
ePcsHPDeskTop( 2021) - DESKTOP
|
||
ePcsMacintosh( 2027) - MC TEXT
|
||
ePcsPC77Baltic( 2087) - PC-775
|
||
ePcsWindows1257Baltic( 2257) - WINBALT"
|
||
::= { prtInterpreterEntry 10 }
|
||
|
||
|
||
prtInterpreterDefaultCharSetOut OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePcsNoDefault(2),
|
||
ePcsASCII(3),
|
||
ePcsHPRoman8(2004),
|
||
ePcsAdobeStandardEncoding(2005)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The default character set for data coming from this interpreter
|
||
through the printer's output channel (i.e. the 'backchannel').
|
||
This value shall be (2) if there is no default."
|
||
::= { prtInterpreterEntry 11 }
|
||
|
||
|
||
prtInterpreterTwoWay OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePyes(3),
|
||
ePno(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "Indicates whether or not this interpreter returns information
|
||
back to the host."
|
||
::= { prtInterpreterEntry 12 }
|
||
|
||
|
||
prtConsoleDisplayBufferText OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The content of a line in the logical display buffer of
|
||
the operator's console of the printer. When a write
|
||
operation occurs, normally a critical message, to one of
|
||
the LineText strings, the agent should make that line
|
||
displayable if a physical display is present. Writing
|
||
a zero length string clears the line. It is an
|
||
implementation-specific matter as to whether the agent allows
|
||
a line to be overwritten before it has been cleared.
|
||
Printer generated strings shall be in the localization
|
||
specified by prtConsoleLocalization. Management Application
|
||
generated strings should be localized by the Management
|
||
Application.
|
||
Additional information:
|
||
In the case of a 2-line display message,
|
||
prtConsoleDisplayBufferText.1 maps to the first
|
||
line and prtConsoleDisplayBufferText.2 maps to
|
||
the second. In the case of a 1-line display
|
||
message, prtConsoleDisplayBufferText.1 maps to
|
||
the first line and prtConsoleDisplayBufferText.2
|
||
return NULL."
|
||
::= { prtConsoleDisplayBufferEntry 2 }
|
||
|
||
|
||
prtConsoleOnTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object, in conjunction with prtConsoleOffTime, defines
|
||
the current status of the light. If both prtConsoleOnTime and
|
||
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
||
values presented define the on time and off time, respectively,
|
||
in milliseconds. If prtConsoleOnTime is zero and
|
||
prtConsoleOffTime is non-zero, the lamp is off. If
|
||
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
|
||
the lamp is on. If both values are zero the status of the
|
||
lamp is undefined.
|
||
Additional information:
|
||
There are two control panel LEDs: Attention
|
||
and Ready. When an LED blinks, it is on for one half
|
||
second and off for one half second. The value used for this
|
||
object is 500 when the LED is on or blinking, otherwise it is
|
||
zero.
|
||
|
||
When the LEDs are in a cycling state the value of this object
|
||
for all LEDs is zero and the value for prtConsoleOffTime for
|
||
all LEDs is zero."
|
||
::= { prtConsoleLightEntry 2 }
|
||
|
||
|
||
prtConsoleOffTime OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "This object, in conjunction with prtConsoleOnTime, defines
|
||
the current status of the light. If both prtConsoleOnTime and
|
||
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
||
values presented define the on time and off time, respectively,
|
||
in milliseconds. If prtConsoleOnTime is zero and
|
||
prtConsoleOffTime is non-zero, the lamp is off. If
|
||
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
|
||
the lamp is on. If both values are zero the status of the
|
||
lamp is undefined.
|
||
Additional information:
|
||
There are 2 control panel LEDs: Attention
|
||
and Ready. When an LED blinks, it is on for one half
|
||
second and off for one half second. The value used for this
|
||
object is 500 when the LED is off or blinking, otherwise it
|
||
is
|
||
zero.
|
||
|
||
When the LEDs are in a cycling state the value of this object
|
||
for all LEDs is zero and the value for prtConsoleOnTime for
|
||
all LEDs is zero."
|
||
::= { prtConsoleLightEntry 3 }
|
||
|
||
|
||
prtConsoleColor OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
ePother(1),
|
||
ePunknown(2),
|
||
ePwhite(3),
|
||
ePred(4),
|
||
ePgreen(5),
|
||
ePblue(6),
|
||
ePcyan(7),
|
||
ePmagenta(8),
|
||
ePyellow(9),
|
||
ePorange(10)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The color of this light."
|
||
::= { prtConsoleLightEntry 4 }
|
||
|
||
|
||
prtConsoleDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE(0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION "The vendor description or label of this light in the
|
||
localization specified by prtConsoleLocalization."
|
||
::= { prtConsoleLightEntry 5 }
|
||
|
||
|
||
END
|