-- Copyright (c) 2010-2014 Hewlett-Packard Development Company, L.P.
|
|
--
|
|
-- Description: RDDC MIB
|
|
-- Reference: Enterprise MIB
|
|
-- Version: V1.0
|
|
-- History:
|
|
-- V1.0 Initial version 2014-01-03
|
|
-- =========================================================================
|
|
HPN-ICF-RDDC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Unsigned32, Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
ifIndex, ifDescr
|
|
FROM IF-MIB
|
|
hpnicfCommon
|
|
FROM HPN-ICF-OID-MIB;
|
|
|
|
hpnicfRddc MODULE-IDENTITY
|
|
LAST-UPDATED "201401030000Z" -- January 03, 2014 at 00:00 GMT
|
|
ORGANIZATION
|
|
""
|
|
CONTACT-INFO
|
|
""
|
|
DESCRIPTION
|
|
"Redundancy group is concerned with ensuring minimal disruption to
|
|
data and control planes in case of a failover. If one of the
|
|
group-node in an IRF fails, the other group-node in the IRF takes over the
|
|
function of the failed group-node with minimal service interruption.
|
|
This module defines the objects pertaining to redundancy group(RDDC)."
|
|
REVISION "201401030000Z" -- January 03, 2014 at 00:00 GMT
|
|
DESCRIPTION "Creation Date."
|
|
::= { hpnicfCommon 151 }
|
|
|
|
hpnicfRddcNotifications OBJECT IDENTIFIER ::= { hpnicfRddc 0 }
|
|
hpnicfRddcObjects OBJECT IDENTIFIER ::= { hpnicfRddc 1 }
|
|
|
|
hpnicfRddcInfo OBJECT IDENTIFIER ::= { hpnicfRddcObjects 1 }
|
|
hpnicfRddcTrapObjects OBJECT IDENTIFIER ::= { hpnicfRddcObjects 2 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- The redundancy group status Table
|
|
-- ---------------------------------------------------------- --
|
|
|
|
hpnicfRddcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpnicfRddcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes the current status of redundancy groups."
|
|
::= { hpnicfRddcInfo 1 }
|
|
|
|
hpnicfRddcEntry OBJECT-TYPE
|
|
SYNTAX HpnicfRddcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry of hpnicfRddcEntry."
|
|
INDEX { hpnicfRddcGroupIdx }
|
|
::= { hpnicfRddcTable 1 }
|
|
|
|
HpnicfRddcEntry ::=
|
|
SEQUENCE {
|
|
hpnicfRddcGroupIdx Unsigned32,
|
|
hpnicfRddcGroupName OCTET STRING,
|
|
hpnicfRddcPreempTimeRemain Unsigned32,
|
|
hpnicfRddcPreempTimeConfig Unsigned32,
|
|
hpnicfRddcHoldTimeRemain Unsigned32,
|
|
hpnicfRddcHoldTimeConfig Unsigned32
|
|
}
|
|
|
|
hpnicfRddcGroupIdx OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique identifier of this redundancy group. 0 is an invalid value."
|
|
::= { hpnicfRddcEntry 1 }
|
|
|
|
hpnicfRddcGroupName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique identifier of this redundancy group."
|
|
::= { hpnicfRddcEntry 2 }
|
|
|
|
hpnicfRddcPreempTimeRemain OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The redundancy group should not switch back immediately
|
|
when a failover is recovered. The preempt delay timer is started
|
|
for waiting the failover became believable.
|
|
This object contains the current preempt delay time remained
|
|
when a failover is recovered."
|
|
::= { hpnicfRddcEntry 3 }
|
|
|
|
hpnicfRddcPreempTimeConfig OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current preempt delay time."
|
|
::= { hpnicfRddcEntry 4 }
|
|
|
|
hpnicfRddcHoldTimeRemain OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To prevent frequent switchovers of the redundancy group,
|
|
the hold-down timer started to keeping in a state for
|
|
a fixed time.
|
|
This object contains the current remained hold-down time
|
|
when a switchover or a failover recovery occurred."
|
|
::= { hpnicfRddcEntry 5 }
|
|
|
|
hpnicfRddcHoldTimeConfig OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current hold-down time."
|
|
::= { hpnicfRddcEntry 6 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- The redundancy group node Table
|
|
-- ---------------------------------------------------------- --
|
|
|
|
hpnicfRddcNodeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpnicfRddcNodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table describes the current status of a redundancy group node."
|
|
::= { hpnicfRddcInfo 2 }
|
|
|
|
hpnicfRddcNodeEntry OBJECT-TYPE
|
|
SYNTAX HpnicfRddcNodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry of hpnicfRddcNodeEntry."
|
|
INDEX { hpnicfRddcNodeGroupIdx,
|
|
hpnicfRddcNodeId }
|
|
::= { hpnicfRddcNodeTable 1 }
|
|
|
|
HpnicfRddcNodeEntry ::=
|
|
SEQUENCE {
|
|
hpnicfRddcNodeGroupIdx Unsigned32,
|
|
hpnicfRddcNodeId Unsigned32,
|
|
hpnicfRddcNodeBindType INTEGER,
|
|
hpnicfRddcNodeBindInfo Unsigned32,
|
|
hpnicfRddcNodePriority Unsigned32,
|
|
hpnicfRddcNodeWeight Integer32,
|
|
hpnicfRddcNodeStatus INTEGER
|
|
}
|
|
|
|
hpnicfRddcNodeGroupIdx OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique identifier of this redundancy group. 0 is an invalid value."
|
|
::= { hpnicfRddcNodeEntry 1 }
|
|
|
|
hpnicfRddcNodeId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique identifier of this redundancy group node. 0 is an invalid value."
|
|
::= { hpnicfRddcNodeEntry 2 }
|
|
|
|
hpnicfRddcNodeBindType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
chassis(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bind type of this redundancy group node.
|
|
The current version only supports binding chassis of an IRF device."
|
|
::= { hpnicfRddcNodeEntry 3 }
|
|
|
|
hpnicfRddcNodeBindInfo OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bind information of this redundancy group node.
|
|
The current version only supports binding chassis of an IRF device.
|
|
If the value of hpnicfRddcNodeBindType is invalid, the value of hpnicfRddcNodeBindInfo is 65535."
|
|
::= { hpnicfRddcNodeEntry 4 }
|
|
|
|
hpnicfRddcNodePriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority of this redundancy group node. The higher the value, the greater the priority."
|
|
::= { hpnicfRddcNodeEntry 5 }
|
|
|
|
hpnicfRddcNodeWeight OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current weight of this redundancy group node. The max value is 255."
|
|
::= { hpnicfRddcNodeEntry 6 }
|
|
|
|
hpnicfRddcNodeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(1),
|
|
master(2),
|
|
standby(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of this redundancy group node."
|
|
::= { hpnicfRddcNodeEntry 7 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- The redundancy group trap objects Table
|
|
-- ---------------------------------------------------------- --
|
|
|
|
hpnicfRddcNodeInfo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains node identification information
|
|
where the switchover occurred."
|
|
::= { hpnicfRddcTrapObjects 1 }
|
|
|
|
hpnicfRddcSwitchReason OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the cause for switchover."
|
|
::= { hpnicfRddcTrapObjects 2 }
|
|
|
|
-- ==================================================================
|
|
--
|
|
-- ======================= trap definition begin ====================
|
|
--
|
|
-- ==================================================================
|
|
hpnicfRddcSwitchoverTrap NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hpnicfRddcGroupIdx,
|
|
hpnicfRddcGroupName,
|
|
hpnicfRddcNodeInfo,
|
|
hpnicfRddcSwitchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification to signal switchover/failover."
|
|
::= { hpnicfRddcNotifications 1 }
|
|
|
|
hpnicfRddcFailIfRecoverTrap NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hpnicfRddcGroupIdx,
|
|
hpnicfRddcGroupName,
|
|
ifIndex,
|
|
ifDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification to signal the failed interface recovered."
|
|
::= { hpnicfRddcNotifications 2 }
|
|
|
|
hpnicfRddcFailIfGenerateTrap NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hpnicfRddcGroupIdx,
|
|
hpnicfRddcGroupName,
|
|
ifIndex,
|
|
ifDescr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification to signal the failed interface generated."
|
|
::= { hpnicfRddcNotifications 3 }
|
|
|
|