158 lines
4.6 KiB
Plaintext
158 lines
4.6 KiB
Plaintext
-- ===========================================================
|
|
-- Copyright (c) 2010-2013 Hewlett-Packard Development Company, L.P.
|
|
--
|
|
-- Description:
|
|
-- The information of EPON fiber backup.
|
|
-- Reference:
|
|
-- Version: V1.0
|
|
-- History:
|
|
-- V1.0 created by zhaodan.
|
|
-- Initial version for hpnicfEponFBMibObjects of hpnicfEpon.
|
|
-- ===========================================================
|
|
HPN-ICF-EPON-FB-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hpnicfEpon
|
|
FROM HPN-ICF-OID-MIB
|
|
Integer32, OBJECT-TYPE, MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
hpnicfEponFBMibObjects MODULE-IDENTITY
|
|
LAST-UPDATED "200711271008Z"
|
|
ORGANIZATION
|
|
""
|
|
CONTACT-INFO
|
|
""
|
|
DESCRIPTION
|
|
"
|
|
The objects in this MIB module are used to manage and
|
|
display current configuration of fiber backup groups
|
|
based on EPON OLT port.
|
|
"
|
|
::= { hpnicfEpon 6 }
|
|
|
|
hpnicfEponFBMIB OBJECT IDENTIFIER ::= { hpnicfEponFBMibObjects 1 }
|
|
--
|
|
-- hpnicfEponFBMIBTable
|
|
--
|
|
|
|
hpnicfEponFBMIBTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpnicfEponFBMIBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table defines several optical fiber-backup system parameters."
|
|
::= { hpnicfEponFBMIB 1 }
|
|
|
|
hpnicfEponFBMIBEntry OBJECT-TYPE
|
|
SYNTAX HpnicfEponFBMIBEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry of hpnicfEponFBMIBTable."
|
|
INDEX
|
|
{
|
|
hpnicfEponFBGroupIndex
|
|
}
|
|
::= { hpnicfEponFBMIBTable 1}
|
|
|
|
|
|
HpnicfEponFBMIBEntry ::= SEQUENCE
|
|
{
|
|
hpnicfEponFBGroupIndex Integer32,
|
|
hpnicfEponFBGroupRowStatus RowStatus,
|
|
hpnicfEponFBMasterPort Integer32,
|
|
hpnicfEponFBSlavePort Integer32,
|
|
hpnicfEponFBMasterPortStatus INTEGER,
|
|
hpnicfEponFBSlavePortStatus INTEGER,
|
|
hpnicfEponFBSwitchover INTEGER
|
|
}
|
|
|
|
hpnicfEponFBGroupIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The EPON fiber-backup group ID."
|
|
::= { hpnicfEponFBMIBEntry 1 }
|
|
|
|
hpnicfEponFBGroupRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows entry to be created and deleted
|
|
from the hpnicfEponFBMIBTable."
|
|
::= { hpnicfEponFBMIBEntry 2 }
|
|
|
|
hpnicfEponFBMasterPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OLT port ifindex of the fiber-backup group.
|
|
Use it to set or get the group master port."
|
|
::= { hpnicfEponFBMIBEntry 3 }
|
|
|
|
hpnicfEponFBSlavePort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OLT port ifindex of the fiber-backup group.
|
|
Use it to set or get the group slave port.
|
|
hpnicfEponFBSlavePort must be set after hpnicfEponFBMasterPort.
|
|
"
|
|
::= { hpnicfEponFBMIBEntry 4 }
|
|
|
|
hpnicfEponFBMasterPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
active(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The master port status of the fiber-backup group.
|
|
The active state indicates that the port's role is master, the olt chip is right
|
|
and the optical module is inserted.
|
|
The down state indicates others conditions."
|
|
::= { hpnicfEponFBMIBEntry 5 }
|
|
|
|
hpnicfEponFBSlavePortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ready(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slave port status of the fiber-backup group.
|
|
The ready state indicates that the port's role is slave, the olt chip is right
|
|
and optical module is inserted.
|
|
The down state indicates others conditions."
|
|
::= { hpnicfEponFBMIBEntry 6 }
|
|
|
|
hpnicfEponFBSwitchover OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
false(1),
|
|
true(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Switch the fiber backup group's two port manually.
|
|
The group must has two ports
|
|
and the value of hpnicfEponFBSlavePortStatus must be ready before Switchover.
|
|
after Switchover the port's role will be changed.
|
|
The value true is for switch-over. The default value is false."
|
|
::= { hpnicfEponFBMIBEntry 7 }
|
|
|
|
END
|