-- THIS MIB CREATED TO REDUCE DUPLICATION BETWEEN HP LASERJET MIBS
|
|
--
|
|
-- Notes:
|
|
--
|
|
-- 1) Objects containing a string which are defined in this MIB use the
|
|
-- first two bytes to hold the symbol set used to encode the string.
|
|
-- The Roman-8 symbol set has a hex encoding of 0x0115. Other
|
|
-- symbol sets are listed in the PCL 5 Comparison Guide in table
|
|
-- C-1 Symbol Set Values.
|
|
--
|
|
HP-LASERJET-COMMON-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises FROM SNMPv2-SMI
|
|
DisplayString FROM SNMPv2-TC;
|
|
|
|
hp MODULE-IDENTITY
|
|
LAST-UPDATED "202005180000Z" --May 17, 2020 00:00 GMT
|
|
ORGANIZATION "Hewlett-Packard Company"
|
|
CONTACT-INFO "Customer Care Center"
|
|
DESCRIPTION "Objects used in HP JetDirect Print Servers"
|
|
|
|
REVISION "202005180000Z"
|
|
DESCRIPTION "Copied multiple Oids from FUTURESMART-MIB."
|
|
|
|
::= { enterprises 11 }
|
|
|
|
|
|
-- hp OBJECT IDENTIFIER ::= { enterprises 11 }
|
|
nm OBJECT IDENTIFIER ::= { hp 2 }
|
|
hpsystem OBJECT IDENTIFIER ::= { nm 3 }
|
|
net-peripheral OBJECT IDENTIFIER ::= { hpsystem 9 }
|
|
netdm OBJECT IDENTIFIER ::= { net-peripheral 4 }
|
|
dm OBJECT IDENTIFIER ::= { netdm 2 }
|
|
|
|
device OBJECT IDENTIFIER ::= { dm 1 }
|
|
device-system OBJECT IDENTIFIER ::= { device 1 }
|
|
|
|
settings-system OBJECT IDENTIFIER ::= { device-system 1 }
|
|
status-system OBJECT IDENTIFIER ::= { device-system 2 }
|
|
|
|
test OBJECT IDENTIFIER ::= { device-system 5 }
|
|
|
|
job OBJECT IDENTIFIER ::= { device-system 6 }
|
|
|
|
job-info OBJECT IDENTIFIER ::= { job 5 }
|
|
job-info-accounting OBJECT IDENTIFIER ::= { job-info 28 }
|
|
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
|
|
pml OBJECT IDENTIFIER ::= { processing-subsystem 4 }
|
|
accounting OBJECT IDENTIFIER ::= { device-system 16 }
|
|
|
|
printer-accounting OBJECT IDENTIFIER ::= { accounting 1 }
|
|
printed-media-usage OBJECT IDENTIFIER ::= { printer-accounting 1 }
|
|
printer-color-accounting OBJECT IDENTIFIER ::= { accounting 3 }
|
|
printed-media-color-usage OBJECT IDENTIFIER ::= { printer-color-accounting 1 }
|
|
printed-modes-accounting OBJECT IDENTIFIER ::= { accounting 4 }
|
|
printed-modes-usage OBJECT IDENTIFIER ::= { printed-modes-accounting 1 }
|
|
source-tray-accounting OBJECT IDENTIFIER ::= { accounting 5 }
|
|
source-tray-usage OBJECT IDENTIFIER ::= { source-tray-accounting 1 }
|
|
destination-bin-accounting OBJECT IDENTIFIER ::= { accounting 6 }
|
|
destination-bin-usage OBJECT IDENTIFIER ::= { destination-bin-accounting 1 }
|
|
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
|
|
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
|
|
print-media OBJECT IDENTIFIER ::= { print-engine 8 }
|
|
media-size OBJECT IDENTIFIER ::= { print-media 5 }
|
|
background-message OBJECT IDENTIFIER ::= { status-system 37 }
|
|
background-message1 OBJECT IDENTIFIER ::= { background-message 1 }
|
|
background-message2 OBJECT IDENTIFIER ::= { background-message 2 }
|
|
control-panel-display OBJECT IDENTIFIER ::= { status-system 65 }
|
|
|
|
id OBJECT IDENTIFIER ::= { device-system 3 }
|
|
|
|
interface OBJECT IDENTIFIER ::= { device-system 4 }
|
|
at OBJECT IDENTIFIER ::= { interface 2 }
|
|
at1 OBJECT IDENTIFIER ::= { at 1 }
|
|
imaging OBJECT IDENTIFIER ::= { print-engine 6 }
|
|
simm OBJECT IDENTIFIER ::= { interface 1 }
|
|
simm1 OBJECT IDENTIFIER ::= { simm 1 }
|
|
simm1-bank OBJECT IDENTIFIER ::= { simm1 6 }
|
|
simm1-bank1 OBJECT IDENTIFIER ::= { simm1-bank 1 }
|
|
simm1-bank2 OBJECT IDENTIFIER ::= { simm1-bank 2 }
|
|
simm2 OBJECT IDENTIFIER ::= { simm 2 }
|
|
simm2-bank OBJECT IDENTIFIER ::= { simm2 6 }
|
|
simm2-bank1 OBJECT IDENTIFIER ::= { simm2-bank 1 }
|
|
simm2-bank2 OBJECT IDENTIFIER ::= { simm2-bank 2 }
|
|
simm3-bank OBJECT IDENTIFIER ::= { simm3 6 }
|
|
simm3-bank1 OBJECT IDENTIFIER ::= { simm3-bank 1 }
|
|
simm3-bank2 OBJECT IDENTIFIER ::= { simm3-bank 2 }
|
|
simm3 OBJECT IDENTIFIER ::= { simm 3 }
|
|
simm4 OBJECT IDENTIFIER ::= { simm 4 }
|
|
simm5 OBJECT IDENTIFIER ::= { simm 5 }
|
|
simm6 OBJECT IDENTIFIER ::= { simm 6 }
|
|
simm7 OBJECT IDENTIFIER ::= { simm 7 }
|
|
simm8 OBJECT IDENTIFIER ::= { simm 8 }
|
|
|
|
settings-job OBJECT IDENTIFIER ::= { job 1 }
|
|
operating-system OBJECT IDENTIFIER ::= { device-system 19 }
|
|
phd OBJECT IDENTIFIER ::= { interface 5 }
|
|
phd1 OBJECT IDENTIFIER ::= { phd 1 }
|
|
phd2 OBJECT IDENTIFIER ::= { phd 2 }
|
|
phd3 OBJECT IDENTIFIER ::= { phd 3 }
|
|
phd4 OBJECT IDENTIFIER ::= { phd 4 }
|
|
phd5 OBJECT IDENTIFIER ::= { phd 5 }
|
|
phd6 OBJECT IDENTIFIER ::= { phd 6 }
|
|
|
|
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
|
|
settings-pdl OBJECT IDENTIFIER ::= { pdl 1 }
|
|
status-pdl OBJECT IDENTIFIER ::= { pdl 2 }
|
|
menus OBJECT IDENTIFIER ::= { print-engine 13 }
|
|
errorlog OBJECT IDENTIFIER ::= { device-system 11 }
|
|
error1 OBJECT IDENTIFIER ::= { errorlog 1 }
|
|
error2 OBJECT IDENTIFIER ::= { errorlog 2 }
|
|
error3 OBJECT IDENTIFIER ::= { errorlog 3 }
|
|
error4 OBJECT IDENTIFIER ::= { errorlog 4 }
|
|
error5 OBJECT IDENTIFIER ::= { errorlog 5 }
|
|
error6 OBJECT IDENTIFIER ::= { errorlog 6 }
|
|
error7 OBJECT IDENTIFIER ::= { errorlog 7 }
|
|
error8 OBJECT IDENTIFIER ::= { errorlog 8 }
|
|
error9 OBJECT IDENTIFIER ::= { errorlog 9 }
|
|
error10 OBJECT IDENTIFIER ::= { errorlog 10 }
|
|
error11 OBJECT IDENTIFIER ::= { errorlog 11 }
|
|
error12 OBJECT IDENTIFIER ::= { errorlog 12 }
|
|
error13 OBJECT IDENTIFIER ::= { errorlog 13 }
|
|
error14 OBJECT IDENTIFIER ::= { errorlog 14 }
|
|
error15 OBJECT IDENTIFIER ::= { errorlog 15 }
|
|
error16 OBJECT IDENTIFIER ::= { errorlog 16 }
|
|
error17 OBJECT IDENTIFIER ::= { errorlog 17 }
|
|
error18 OBJECT IDENTIFIER ::= { errorlog 18 }
|
|
error19 OBJECT IDENTIFIER ::= { errorlog 19 }
|
|
error20 OBJECT IDENTIFIER ::= { errorlog 20 }
|
|
error21 OBJECT IDENTIFIER ::= { errorlog 21 }
|
|
error22 OBJECT IDENTIFIER ::= { errorlog 22 }
|
|
error23 OBJECT IDENTIFIER ::= { errorlog 23 }
|
|
error24 OBJECT IDENTIFIER ::= { errorlog 24 }
|
|
error25 OBJECT IDENTIFIER ::= { errorlog 25 }
|
|
error26 OBJECT IDENTIFIER ::= { errorlog 26 }
|
|
error27 OBJECT IDENTIFIER ::= { errorlog 27 }
|
|
error28 OBJECT IDENTIFIER ::= { errorlog 28 }
|
|
error29 OBJECT IDENTIFIER ::= { errorlog 29 }
|
|
error30 OBJECT IDENTIFIER ::= { errorlog 30 }
|
|
error31 OBJECT IDENTIFIER ::= { errorlog 31 }
|
|
error32 OBJECT IDENTIFIER ::= { errorlog 32 }
|
|
error33 OBJECT IDENTIFIER ::= { errorlog 33 }
|
|
error34 OBJECT IDENTIFIER ::= { errorlog 34 }
|
|
error35 OBJECT IDENTIFIER ::= { errorlog 35 }
|
|
error36 OBJECT IDENTIFIER ::= { errorlog 36 }
|
|
error37 OBJECT IDENTIFIER ::= { errorlog 37 }
|
|
error38 OBJECT IDENTIFIER ::= { errorlog 38 }
|
|
error39 OBJECT IDENTIFIER ::= { errorlog 39 }
|
|
error40 OBJECT IDENTIFIER ::= { errorlog 40 }
|
|
error41 OBJECT IDENTIFIER ::= { errorlog 41 }
|
|
error42 OBJECT IDENTIFIER ::= { errorlog 42 }
|
|
error43 OBJECT IDENTIFIER ::= { errorlog 43 }
|
|
error44 OBJECT IDENTIFIER ::= { errorlog 44 }
|
|
error45 OBJECT IDENTIFIER ::= { errorlog 45 }
|
|
error46 OBJECT IDENTIFIER ::= { errorlog 46 }
|
|
error47 OBJECT IDENTIFIER ::= { errorlog 47 }
|
|
error48 OBJECT IDENTIFIER ::= { errorlog 48 }
|
|
error49 OBJECT IDENTIFIER ::= { errorlog 49 }
|
|
error50 OBJECT IDENTIFIER ::= { errorlog 50 }
|
|
error51 OBJECT IDENTIFIER ::= { errorlog 51 }
|
|
error52 OBJECT IDENTIFIER ::= { errorlog 52 }
|
|
error53 OBJECT IDENTIFIER ::= { errorlog 53 }
|
|
error54 OBJECT IDENTIFIER ::= { errorlog 54 }
|
|
error55 OBJECT IDENTIFIER ::= { errorlog 55 }
|
|
error56 OBJECT IDENTIFIER ::= { errorlog 56 }
|
|
error57 OBJECT IDENTIFIER ::= { errorlog 57 }
|
|
error58 OBJECT IDENTIFIER ::= { errorlog 58 }
|
|
error59 OBJECT IDENTIFIER ::= { errorlog 59 }
|
|
error60 OBJECT IDENTIFIER ::= { errorlog 60 }
|
|
error61 OBJECT IDENTIFIER ::= { errorlog 61 }
|
|
error62 OBJECT IDENTIFIER ::= { errorlog 62 }
|
|
error63 OBJECT IDENTIFIER ::= { errorlog 63 }
|
|
error64 OBJECT IDENTIFIER ::= { errorlog 64 }
|
|
error65 OBJECT IDENTIFIER ::= { errorlog 65 }
|
|
error66 OBJECT IDENTIFIER ::= { errorlog 66 }
|
|
error67 OBJECT IDENTIFIER ::= { errorlog 67 }
|
|
error68 OBJECT IDENTIFIER ::= { errorlog 68 }
|
|
error69 OBJECT IDENTIFIER ::= { errorlog 69 }
|
|
error70 OBJECT IDENTIFIER ::= { errorlog 70 }
|
|
error71 OBJECT IDENTIFIER ::= { errorlog 71 }
|
|
error72 OBJECT IDENTIFIER ::= { errorlog 72 }
|
|
error73 OBJECT IDENTIFIER ::= { errorlog 73 }
|
|
error74 OBJECT IDENTIFIER ::= { errorlog 74 }
|
|
error75 OBJECT IDENTIFIER ::= { errorlog 75 }
|
|
error76 OBJECT IDENTIFIER ::= { errorlog 76 }
|
|
error77 OBJECT IDENTIFIER ::= { errorlog 77 }
|
|
error78 OBJECT IDENTIFIER ::= { errorlog 78 }
|
|
error79 OBJECT IDENTIFIER ::= { errorlog 79 }
|
|
error80 OBJECT IDENTIFIER ::= { errorlog 80 }
|
|
error81 OBJECT IDENTIFIER ::= { errorlog 81 }
|
|
error82 OBJECT IDENTIFIER ::= { errorlog 82 }
|
|
error83 OBJECT IDENTIFIER ::= { errorlog 83 }
|
|
error84 OBJECT IDENTIFIER ::= { errorlog 84 }
|
|
error85 OBJECT IDENTIFIER ::= { errorlog 85 }
|
|
error86 OBJECT IDENTIFIER ::= { errorlog 86 }
|
|
error87 OBJECT IDENTIFIER ::= { errorlog 87 }
|
|
error88 OBJECT IDENTIFIER ::= { errorlog 88 }
|
|
error89 OBJECT IDENTIFIER ::= { errorlog 89 }
|
|
error90 OBJECT IDENTIFIER ::= { errorlog 90 }
|
|
|
|
channel OBJECT IDENTIFIER ::= { device 6 }
|
|
channelTable OBJECT IDENTIFIER ::= { channel 3 }
|
|
channelEntry OBJECT IDENTIFIER ::= { channelTable 1 }
|
|
display OBJECT IDENTIFIER ::= { status-system 20 }
|
|
display-status OBJECT IDENTIFIER ::= { display 1 }
|
|
status-message OBJECT IDENTIFIER ::= { display 2 }
|
|
status-message1 OBJECT IDENTIFIER ::= { status-message 1 }
|
|
web-server OBJECT IDENTIFIER ::= { interface 6 }
|
|
settings-web-server OBJECT IDENTIFIER ::= { web-server 1 }
|
|
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
|
|
webserver-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 9 }
|
|
settings-webserver OBJECT IDENTIFIER ::= { webserver-proc-sub 1 }
|
|
settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 }
|
|
intray OBJECT IDENTIFIER ::= { print-engine 3 }
|
|
settings-intray OBJECT IDENTIFIER ::= { intray 1 }
|
|
status-intray OBJECT IDENTIFIER ::= { intray 2 }
|
|
ph OBJECT IDENTIFIER ::= { print-engine 7 }
|
|
settings-ph OBJECT IDENTIFIER ::= { ph 1 }
|
|
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
|
|
pdl-esc-p OBJECT IDENTIFIER ::= { pdl 5 }
|
|
pdl-pdf OBJECT IDENTIFIER ::= { pdl 15 }
|
|
pdl-pclxl OBJECT IDENTIFIER ::= { pdl 16 }
|
|
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
|
|
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
|
|
job-info-attribute OBJECT IDENTIFIER ::= { job-info 23 }
|
|
fax-job-control OBJECT IDENTIFIER ::= { job 3 }
|
|
settings-fax-job OBJECT IDENTIFIER ::= { fax-job-control 1 }
|
|
status-fax-job OBJECT IDENTIFIER ::= { fax-job-control 2 }
|
|
faxjob OBJECT IDENTIFIER ::= { fax-job-control 3 }
|
|
faxjob-rx-status OBJECT IDENTIFIER ::= { faxjob 1 }
|
|
faxjob-tx-status OBJECT IDENTIFIER ::= { faxjob 3 }
|
|
faxjob-tx-error OBJECT IDENTIFIER ::= { faxjob 4 }
|
|
faxjob-tx-current-page OBJECT IDENTIFIER ::= { faxjob 5 }
|
|
faxjob-rx-current-page OBJECT IDENTIFIER ::= { faxjob 6 }
|
|
faxjob-rx-duration OBJECT IDENTIFIER ::= { faxjob 7 }
|
|
faxjob-tx-duration OBJECT IDENTIFIER ::= { faxjob 8 }
|
|
fax-activity-log OBJECT IDENTIFIER ::= { job 4 }
|
|
settings-faxlog OBJECT IDENTIFIER ::= { fax-activity-log 1 }
|
|
settings-fax-proc-sub OBJECT IDENTIFIER ::= { fax-proc-sub 1 }
|
|
status-fax-proc-sub OBJECT IDENTIFIER ::= { fax-proc-sub 2 }
|
|
fax-forwarding OBJECT IDENTIFIER ::= { fax-proc-sub 3 }
|
|
fax-receive OBJECT IDENTIFIER ::= { source-subsystem 3 }
|
|
settings-fax-receive OBJECT IDENTIFIER ::= { fax-receive 1 }
|
|
status-fax-receive OBJECT IDENTIFIER ::= { fax-receive 2 }
|
|
held-job OBJECT IDENTIFIER ::= { job 7 }
|
|
held-job-info OBJECT IDENTIFIER ::= { held-job 1 }
|
|
held-job-control OBJECT IDENTIFIER ::= { held-job 2 }
|
|
photo-job OBJECT IDENTIFIER ::= { job 8 }
|
|
settings-photo-job OBJECT IDENTIFIER ::= { photo-job 3 }
|
|
|
|
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
|
|
spooler OBJECT IDENTIFIER ::= { source-subsystem 4 }
|
|
settings-spooler OBJECT IDENTIFIER ::= { spooler 1 }
|
|
pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 }
|
|
mio OBJECT IDENTIFIER ::= { interface 3 }
|
|
mio1 OBJECT IDENTIFIER ::= { mio 1 }
|
|
mio2 OBJECT IDENTIFIER ::= { mio 2 }
|
|
mio3 OBJECT IDENTIFIER ::= { mio 3 }
|
|
mio4 OBJECT IDENTIFIER ::= { mio 4 }
|
|
usb-interface OBJECT IDENTIFIER ::= { interface 9 }
|
|
usb OBJECT IDENTIFIER ::= { usb-interface 2 }
|
|
io OBJECT IDENTIFIER ::= { source-subsystem 1 }
|
|
settings-io OBJECT IDENTIFIER ::= { io 1 }
|
|
status-io OBJECT IDENTIFIER ::= { io 2 }
|
|
ports OBJECT IDENTIFIER ::= { io 3 }
|
|
port1 OBJECT IDENTIFIER ::= { ports 1 }
|
|
parallel OBJECT IDENTIFIER ::= { port1 1 }
|
|
foreign-interface OBJECT IDENTIFIER ::= { interface 8 }
|
|
fax-send OBJECT IDENTIFIER ::= { destination-subsystem 2 }
|
|
settings-fax-send OBJECT IDENTIFIER ::= { fax-send 1 }
|
|
status-fax-send OBJECT IDENTIFIER ::= { fax-send 2 }
|
|
transmit-fax OBJECT IDENTIFIER ::= { fax-send 5 }
|
|
phone OBJECT IDENTIFIER ::= { device-system 9 }
|
|
dial OBJECT IDENTIFIER ::= { phone 1 }
|
|
dial-all-lines OBJECT IDENTIFIER ::= { dial 1 }
|
|
answer OBJECT IDENTIFIER ::= { phone 2 }
|
|
answer-all-lines OBJECT IDENTIFIER ::= { answer 1 }
|
|
fax-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 7 }
|
|
|
|
|
|
tables OBJECT IDENTIFIER ::= { device 7 }
|
|
channel-table OBJECT IDENTIFIER ::= { tables 2 }
|
|
channel-entry OBJECT IDENTIFIER ::= { channel-table 1 }
|
|
remote-procedure-call OBJECT IDENTIFIER ::= { device-system 13 }
|
|
|
|
settings-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 1 }
|
|
status-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 2 }
|
|
rpc-services OBJECT IDENTIFIER ::= { remote-procedure-call 3 }
|
|
file-system OBJECT IDENTIFIER ::= { device-system 10 }
|
|
|
|
settings-file-system OBJECT IDENTIFIER ::= { file-system 1 }
|
|
status-file-system OBJECT IDENTIFIER ::= { file-system 2 }
|
|
file-systems OBJECT IDENTIFIER ::= { file-system 3 }
|
|
file-system1 OBJECT IDENTIFIER ::= { file-systems 1 }
|
|
file-system2 OBJECT IDENTIFIER ::= { file-systems 2 }
|
|
file-system3 OBJECT IDENTIFIER ::= { file-systems 3 }
|
|
file-system4 OBJECT IDENTIFIER ::= { file-systems 4 }
|
|
resource-manager OBJECT IDENTIFIER ::= { device-system 12 }
|
|
|
|
mass-storage-resources OBJECT IDENTIFIER ::= { resource-manager 3 }
|
|
mass-storage-block-driver OBJECT IDENTIFIER ::= { device-system 15 }
|
|
|
|
settings-mass-storage-bd OBJECT IDENTIFIER ::= { mass-storage-block-driver 1 }
|
|
status-mass-storage-bd OBJECT IDENTIFIER ::= { mass-storage-block-driver 2 }
|
|
mass-storage-block-drivers OBJECT IDENTIFIER ::= { mass-storage-block-driver 3 }
|
|
mass-storage-bd2 OBJECT IDENTIFIER ::= { mass-storage-block-drivers 2 }
|
|
settings-msbd2 OBJECT IDENTIFIER ::= { mass-storage-bd2 1 }
|
|
|
|
settings-print-media OBJECT IDENTIFIER ::= { print-media 1 }
|
|
media-info OBJECT IDENTIFIER ::= { print-media 3 }
|
|
media1 OBJECT IDENTIFIER ::= { media-info 1 }
|
|
media2 OBJECT IDENTIFIER ::= { media-info 2 }
|
|
media3 OBJECT IDENTIFIER ::= { media-info 3 }
|
|
media4 OBJECT IDENTIFIER ::= { media-info 4 }
|
|
media5 OBJECT IDENTIFIER ::= { media-info 5 }
|
|
media6 OBJECT IDENTIFIER ::= { media-info 6 }
|
|
media7 OBJECT IDENTIFIER ::= { media-info 7 }
|
|
media8 OBJECT IDENTIFIER ::= { media-info 8 }
|
|
media9 OBJECT IDENTIFIER ::= { media-info 9 }
|
|
media10 OBJECT IDENTIFIER ::= { media-info 10 }
|
|
media11 OBJECT IDENTIFIER ::= { media-info 11 }
|
|
media12 OBJECT IDENTIFIER ::= { media-info 12 }
|
|
media13 OBJECT IDENTIFIER ::= { media-info 13 }
|
|
media14 OBJECT IDENTIFIER ::= { media-info 14 }
|
|
media15 OBJECT IDENTIFIER ::= { media-info 15 }
|
|
media16 OBJECT IDENTIFIER ::= { media-info 16 }
|
|
media17 OBJECT IDENTIFIER ::= { media-info 17 }
|
|
media18 OBJECT IDENTIFIER ::= { media-info 18 }
|
|
media19 OBJECT IDENTIFIER ::= { media-info 19 }
|
|
media20 OBJECT IDENTIFIER ::= { media-info 20 }
|
|
media21 OBJECT IDENTIFIER ::= { media-info 21 }
|
|
media22 OBJECT IDENTIFIER ::= { media-info 22 }
|
|
media23 OBJECT IDENTIFIER ::= { media-info 23 }
|
|
media24 OBJECT IDENTIFIER ::= { media-info 24 }
|
|
media25 OBJECT IDENTIFIER ::= { media-info 25 }
|
|
media26 OBJECT IDENTIFIER ::= { media-info 26 }
|
|
media27 OBJECT IDENTIFIER ::= { media-info 27 }
|
|
media28 OBJECT IDENTIFIER ::= { media-info 28 }
|
|
media29 OBJECT IDENTIFIER ::= { media-info 29 }
|
|
media30 OBJECT IDENTIFIER ::= { media-info 30 }
|
|
media31 OBJECT IDENTIFIER ::= { media-info 31 }
|
|
media32 OBJECT IDENTIFIER ::= { media-info 32 }
|
|
media33 OBJECT IDENTIFIER ::= { media-info 33 }
|
|
media34 OBJECT IDENTIFIER ::= { media-info 34 }
|
|
media35 OBJECT IDENTIFIER ::= { media-info 35 }
|
|
media36 OBJECT IDENTIFIER ::= { media-info 36 }
|
|
media37 OBJECT IDENTIFIER ::= { media-info 37 }
|
|
media38 OBJECT IDENTIFIER ::= { media-info 38 }
|
|
media-types OBJECT IDENTIFIER ::= { print-media 8 }
|
|
media-sizes OBJECT IDENTIFIER ::= { print-engine 15 }
|
|
device-configure OBJECT IDENTIFIER ::= { settings-system 32 }
|
|
marking-agent-density OBJECT IDENTIFIER ::= { settings-prt-eng 9 }
|
|
status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 }
|
|
printer-calibration-dhalf OBJECT IDENTIFIER ::= { status-prt-eng 37 }
|
|
printer-cal-dhalf-data OBJECT IDENTIFIER ::= { printer-calibration-dhalf 3 }
|
|
printer-cal-grayaxis OBJECT IDENTIFIER ::= { printer-calibration-dhalf 6 }
|
|
printer-cal-grayaxis-data OBJECT IDENTIFIER ::= { printer-calibration-dhalf 7 }
|
|
printer-calibration-cpr OBJECT IDENTIFIER ::= { status-prt-eng 38 }
|
|
intrays OBJECT IDENTIFIER ::= { intray 3 }
|
|
intray1 OBJECT IDENTIFIER ::= { intrays 1 }
|
|
intray2 OBJECT IDENTIFIER ::= { intrays 2 }
|
|
intray3 OBJECT IDENTIFIER ::= { intrays 3 }
|
|
intray4 OBJECT IDENTIFIER ::= { intrays 4 }
|
|
intray5 OBJECT IDENTIFIER ::= { intrays 5 }
|
|
intray6 OBJECT IDENTIFIER ::= { intrays 6 }
|
|
intray7 OBJECT IDENTIFIER ::= { intrays 7 }
|
|
outbin OBJECT IDENTIFIER ::= { print-engine 4 }
|
|
settings-outbin OBJECT IDENTIFIER ::= { outbin 1 }
|
|
outbins OBJECT IDENTIFIER ::= { outbin 3 }
|
|
outbin1 OBJECT IDENTIFIER ::= { outbins 1 }
|
|
outbin2 OBJECT IDENTIFIER ::= { outbins 2 }
|
|
outbin3 OBJECT IDENTIFIER ::= { outbins 3 }
|
|
outbin4 OBJECT IDENTIFIER ::= { outbins 4 }
|
|
outbin5 OBJECT IDENTIFIER ::= { outbins 5 }
|
|
outbin6 OBJECT IDENTIFIER ::= { outbins 6 }
|
|
outbin7 OBJECT IDENTIFIER ::= { outbins 7 }
|
|
outbin8 OBJECT IDENTIFIER ::= { outbins 8 }
|
|
outbin9 OBJECT IDENTIFIER ::= { outbins 9 }
|
|
outbin10 OBJECT IDENTIFIER ::= { outbins 10 }
|
|
outbin11 OBJECT IDENTIFIER ::= { outbins 11 }
|
|
marking-agent OBJECT IDENTIFIER ::= { print-engine 5 }
|
|
settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 }
|
|
ph-devices OBJECT IDENTIFIER ::= { ph 3 }
|
|
ph2 OBJECT IDENTIFIER ::= { ph-devices 2 }
|
|
ph3 OBJECT IDENTIFIER ::= { ph-devices 3 }
|
|
ph4 OBJECT IDENTIFIER ::= { ph-devices 4 }
|
|
ph5 OBJECT IDENTIFIER ::= { ph-devices 5 }
|
|
ph6 OBJECT IDENTIFIER ::= { ph-devices 6 }
|
|
media-modes OBJECT IDENTIFIER ::= { print-media 4 }
|
|
media-mode-details OBJECT IDENTIFIER ::= { print-media 6 }
|
|
media-mode1 OBJECT IDENTIFIER ::= { media-mode-details 1 }
|
|
media-mode2 OBJECT IDENTIFIER ::= { media-mode-details 2 }
|
|
media-mode3 OBJECT IDENTIFIER ::= { media-mode-details 3 }
|
|
media-mode4 OBJECT IDENTIFIER ::= { media-mode-details 4 }
|
|
media-mode5 OBJECT IDENTIFIER ::= { media-mode-details 5 }
|
|
media-counts OBJECT IDENTIFIER ::= { print-media 7 }
|
|
consumables OBJECT IDENTIFIER ::= { print-engine 10 }
|
|
consumables-1 OBJECT IDENTIFIER ::= { consumables 1 }
|
|
consumable-status OBJECT IDENTIFIER ::= { consumables-1 1 }
|
|
consumable-string OBJECT IDENTIFIER ::= { consumables 8 }
|
|
consumables-status OBJECT IDENTIFIER ::= { consumables 5 }
|
|
consumables-life OBJECT IDENTIFIER ::= { consumables-status 1 }
|
|
print-meter OBJECT IDENTIFIER ::= { print-engine 11 }
|
|
printer-average OBJECT IDENTIFIER ::= { print-meter 1 }
|
|
jetsend-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 8 }
|
|
settings-jetsend OBJECT IDENTIFIER ::= { jetsend-proc-sub 1 }
|
|
jetsend-contact OBJECT IDENTIFIER ::= { jetsend-proc-sub 3 }
|
|
settings-jetsend-contact OBJECT IDENTIFIER ::= { jetsend-contact 1 }
|
|
mount OBJECT IDENTIFIER ::= { rpc-services 1 }
|
|
settings-mount OBJECT IDENTIFIER ::= { mount 1 }
|
|
nfs-server OBJECT IDENTIFIER ::= { rpc-services 2 }
|
|
settings-nfs-server OBJECT IDENTIFIER ::= { nfs-server 1 }
|
|
status-nfs-server OBJECT IDENTIFIER ::= { nfs-server 2 }
|
|
rpc-bind OBJECT IDENTIFIER ::= { rpc-services 3 }
|
|
settings-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 1 }
|
|
status-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 2 }
|
|
xport-interface OBJECT IDENTIFIER ::= { device-system 14 }
|
|
status-xip OBJECT IDENTIFIER ::= { xport-interface 2 }
|
|
firmware-download OBJECT IDENTIFIER ::= { device-system 18 }
|
|
|
|
upgradable-devices OBJECT IDENTIFIER ::= { device-system 20 }
|
|
|
|
|
|
warninglog OBJECT IDENTIFIER ::= { device-system 22 }
|
|
|
|
warning1 OBJECT IDENTIFIER ::= { warninglog 1 }
|
|
warning2 OBJECT IDENTIFIER ::= { warninglog 2 }
|
|
warning3 OBJECT IDENTIFIER ::= { warninglog 3 }
|
|
warning4 OBJECT IDENTIFIER ::= { warninglog 4 }
|
|
warning5 OBJECT IDENTIFIER ::= { warninglog 5 }
|
|
warning6 OBJECT IDENTIFIER ::= { warninglog 6 }
|
|
warning7 OBJECT IDENTIFIER ::= { warninglog 7 }
|
|
warning8 OBJECT IDENTIFIER ::= { warninglog 8 }
|
|
warning9 OBJECT IDENTIFIER ::= { warninglog 9 }
|
|
warning10 OBJECT IDENTIFIER ::= { warninglog 10 }
|
|
warning11 OBJECT IDENTIFIER ::= { warninglog 11 }
|
|
warning12 OBJECT IDENTIFIER ::= { warninglog 12 }
|
|
warning13 OBJECT IDENTIFIER ::= { warninglog 13 }
|
|
warning14 OBJECT IDENTIFIER ::= { warninglog 14 }
|
|
warning15 OBJECT IDENTIFIER ::= { warninglog 15 }
|
|
warning16 OBJECT IDENTIFIER ::= { warninglog 16 }
|
|
warning17 OBJECT IDENTIFIER ::= { warninglog 17 }
|
|
warning18 OBJECT IDENTIFIER ::= { warninglog 18 }
|
|
warning19 OBJECT IDENTIFIER ::= { warninglog 19 }
|
|
warning20 OBJECT IDENTIFIER ::= { warninglog 20 }
|
|
warning21 OBJECT IDENTIFIER ::= { warninglog 21 }
|
|
warning22 OBJECT IDENTIFIER ::= { warninglog 22 }
|
|
warning23 OBJECT IDENTIFIER ::= { warninglog 23 }
|
|
warning24 OBJECT IDENTIFIER ::= { warninglog 24 }
|
|
warning25 OBJECT IDENTIFIER ::= { warninglog 25 }
|
|
warning26 OBJECT IDENTIFIER ::= { warninglog 26 }
|
|
warning27 OBJECT IDENTIFIER ::= { warninglog 27 }
|
|
warning28 OBJECT IDENTIFIER ::= { warninglog 28 }
|
|
warning29 OBJECT IDENTIFIER ::= { warninglog 29 }
|
|
warning30 OBJECT IDENTIFIER ::= { warninglog 30 }
|
|
warning31 OBJECT IDENTIFIER ::= { warninglog 31 }
|
|
warning32 OBJECT IDENTIFIER ::= { warninglog 32 }
|
|
warning33 OBJECT IDENTIFIER ::= { warninglog 33 }
|
|
warning34 OBJECT IDENTIFIER ::= { warninglog 34 }
|
|
warning35 OBJECT IDENTIFIER ::= { warninglog 35 }
|
|
warning36 OBJECT IDENTIFIER ::= { warninglog 36 }
|
|
warning37 OBJECT IDENTIFIER ::= { warninglog 37 }
|
|
warning38 OBJECT IDENTIFIER ::= { warninglog 38 }
|
|
warning39 OBJECT IDENTIFIER ::= { warninglog 39 }
|
|
warning40 OBJECT IDENTIFIER ::= { warninglog 40 }
|
|
warning41 OBJECT IDENTIFIER ::= { warninglog 41 }
|
|
warning42 OBJECT IDENTIFIER ::= { warninglog 42 }
|
|
warning43 OBJECT IDENTIFIER ::= { warninglog 43 }
|
|
warning44 OBJECT IDENTIFIER ::= { warninglog 44 }
|
|
warning45 OBJECT IDENTIFIER ::= { warninglog 45 }
|
|
warning46 OBJECT IDENTIFIER ::= { warninglog 46 }
|
|
warning47 OBJECT IDENTIFIER ::= { warninglog 47 }
|
|
warning48 OBJECT IDENTIFIER ::= { warninglog 48 }
|
|
warning49 OBJECT IDENTIFIER ::= { warninglog 49 }
|
|
warning50 OBJECT IDENTIFIER ::= { warninglog 50 }
|
|
security OBJECT IDENTIFIER ::= { device-system 23 }
|
|
settings-security OBJECT IDENTIFIER ::= { security 1 }
|
|
scanner OBJECT IDENTIFIER ::= { source-subsystem 2 }
|
|
settings-scanner OBJECT IDENTIFIER ::= { scanner 1 }
|
|
status-scanner OBJECT IDENTIFIER ::= { scanner 2 }
|
|
scan-calibration OBJECT IDENTIFIER ::= { settings-scanner 32 }
|
|
print-meter-usage OBJECT IDENTIFIER ::= { printer-accounting 14 }
|
|
scanner-accounting OBJECT IDENTIFIER ::= { accounting 2 }
|
|
scanned-media-usage OBJECT IDENTIFIER ::= { scanner-accounting 1 }
|
|
settings-system2 OBJECT IDENTIFIER ::= { device-system 25 }
|
|
|
|
printmib OBJECT IDENTIFIER ::= { dm 2 }
|
|
|
|
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
|
|
prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 }
|
|
prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 }
|
|
|
|
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
|
|
prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 }
|
|
prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 }
|
|
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
|
|
prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 }
|
|
prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 }
|
|
|
|
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
|
|
prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 }
|
|
prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 }
|
|
prtStorageRefTable OBJECT IDENTIFIER ::= { prtGeneral 2 }
|
|
prtStorageRefEntry OBJECT IDENTIFIER ::= { prtStorageRefTable 1 }
|
|
prtDeviceRefTable OBJECT IDENTIFIER ::= { prtGeneral 3 }
|
|
prtDeviceRefEntry OBJECT IDENTIFIER ::= { prtDeviceRefTable 1 }
|
|
|
|
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
|
|
prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 }
|
|
prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 }
|
|
|
|
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
|
|
prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 }
|
|
prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 }
|
|
|
|
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
|
|
prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 }
|
|
prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 }
|
|
|
|
prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }
|
|
prtMarkerColorantTable OBJECT IDENTIFIER ::= { prtMarkerColorant 1 }
|
|
prtMarkerColorantEntry OBJECT IDENTIFIER ::= { prtMarkerColorantTable 1 }
|
|
|
|
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
|
|
prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 }
|
|
prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 }
|
|
|
|
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
|
|
prtChannelTable OBJECT IDENTIFIER ::= { prtChannel 1 }
|
|
prtChannelEntry OBJECT IDENTIFIER ::= { prtChannelTable 1 }
|
|
|
|
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
|
|
prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 }
|
|
prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 }
|
|
|
|
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
|
|
prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 }
|
|
prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 }
|
|
|
|
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
|
|
prtConsoleLightTable OBJECT IDENTIFIER ::= { prtConsoleLights 6 }
|
|
prtConsoleLightEntry OBJECT IDENTIFIER ::= { prtConsoleLightTable 1 }
|
|
prtAlert OBJECT IDENTIFIER ::= { printmib 18 }
|
|
prtAlertTable OBJECT IDENTIFIER ::= { prtAlert 1 }
|
|
prtAlertEntry OBJECT IDENTIFIER ::= { prtAlertTable 1 }
|
|
|
|
hrm OBJECT IDENTIFIER ::= { dm 3 }
|
|
|
|
hrStorage OBJECT IDENTIFIER ::= { hrm 2 }
|
|
hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 }
|
|
hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 }
|
|
|
|
hrDevice OBJECT IDENTIFIER ::= { hrm 3 }
|
|
hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 }
|
|
hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 }
|
|
hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 }
|
|
hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 }
|
|
hrDiskStorageTable OBJECT IDENTIFIER ::= { hrDevice 6 }
|
|
hrDiskStorageEntry OBJECT IDENTIFIER ::= { hrDiskStorageTable 1 }
|
|
hrPartitionTable OBJECT IDENTIFIER ::= { hrDevice 7 }
|
|
hrPartitionEntry OBJECT IDENTIFIER ::= { hrPartitionTable 1 }
|
|
hrFSTable OBJECT IDENTIFIER ::= { hrDevice 8 }
|
|
hrFSEntry OBJECT IDENTIFIER ::= { hrFSTable 1 }
|
|
|
|
net-printer OBJECT IDENTIFIER ::= { net-peripheral 1 }
|
|
generalDeviceStatus OBJECT IDENTIFIER ::= { net-printer 1 }
|
|
netPrinterType OBJECT IDENTIFIER ::= { net-printer 2 }
|
|
gdStatusEntry OBJECT IDENTIFIER ::= { generalDeviceStatus 2 }
|
|
|
|
|
|
localization-language OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEnglish(1),
|
|
eFrench(2),
|
|
eGerman(3),
|
|
eSpanish(4),
|
|
eItalian(5),
|
|
eSwedish(6),
|
|
eDanish(7),
|
|
eNorwegian(8),
|
|
eDutch(9),
|
|
eFinnish(10),
|
|
eJapanese(11),
|
|
ePortuguese(12),
|
|
ePolish(13),
|
|
eTurkish(14)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Localization language used by the device for device
|
|
generated PML strings, control panel messages, and text
|
|
contained in any of the printer generated printed pages.
|
|
The order is the same order that is defined in MIO.
|
|
Since the MIO values start at zero, one has been added
|
|
to each value."
|
|
::= { status-system 1 }
|
|
|
|
not-ready-printer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if any of the sub-systems in the printer are
|
|
not ready. A sub-system is not ready if the sub-system
|
|
is unable to perform its function until some sort of
|
|
intervention occurs. If there are no items in the NOT-
|
|
READY-PRINTER collection (i.e. no bits are set), then
|
|
all printer sub- systems are ready. Each sub-system has
|
|
a sub-system specific not ready object. If a sub-system
|
|
specific not ready object contains any items, then the
|
|
associated item will be in the NOT-READY collection."
|
|
::= { status-system 2 }
|
|
|
|
|
|
not-ready-controller OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the hardware controller sub-system in the
|
|
device is not ready. If there are no items in the
|
|
collection (i.e. no bits are set), then the hardware
|
|
controller sub-system is ready. If there is an item
|
|
present, then the item indicates what is causing the
|
|
hardware controller sub-system to be not ready. If the
|
|
cControllerFailure item is in the collection, then a
|
|
hardware error was detected on the main controller PC
|
|
board, sometimes called the formatter or the logic
|
|
broad. Example controller hardware errors include DRAM
|
|
controller failure, clock failure, memory parity error,
|
|
and ROM CRC error. The cFirmwareFailure item is in the
|
|
collection if a firmware/software error was detected.
|
|
Device specific detailed error information can be
|
|
retrieved from the error log objects, if the device
|
|
supports those objects. The POS will list which device
|
|
failures cause each item to be included in the
|
|
collection.
|
|
Additional information:
|
|
A controller failure occurrence will set the
|
|
cControllerFailure bit (bit 1). The controller
|
|
failures are: 62.X Service, 63 Service, 65 Service,
|
|
67 Service, 68 Service, and 68 Error.
|
|
A SIMM failure occurrence will set the cSIMMFailure
|
|
bit (bit 2). The SIMM failures are 61.X Service,
|
|
53-XY-ZZ Error, and 72 Service.
|
|
A DISK failure occurrence will set the cATFailure
|
|
bit (bit 3). The DISK failure is FS DISK FAILURE."
|
|
::= { status-system 3 }
|
|
|
|
|
|
not-idle OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if any of the sub-systems in the device are
|
|
not idle. The I/O source sub-system is considered not
|
|
idle if there is unprocessed PDL data in the device.
|
|
The PDL processing sub-system is considered not idle if
|
|
the device is processing a print job. The print engine
|
|
destination sub-system is considered not idle if media
|
|
is moving (i.e. the device is printing). [other text
|
|
here describing what causes the other sub-systems to be
|
|
considered not idle]."
|
|
::= { status-system 4 }
|
|
|
|
on-off-line OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOnline(1),
|
|
eOffline(2),
|
|
eOfflineAtEndOfJob(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To bring the PDL processing sub-system on or off line.
|
|
If the device is a printer, then the printer does not
|
|
process print job data when the printer is off line.
|
|
PML communication persists.
|
|
Additional information:
|
|
When the printer is in the Offline state,
|
|
printing will stop as soon as possible (no more sheets
|
|
of media are pulled from input trays). The I/O
|
|
is taken offline also.
|
|
|
|
Setting to eOnline has the following affect:
|
|
Printer will immediately go to or remain in the Online
|
|
state; <noError> status is returned.
|
|
If the printer's current state
|
|
is Offline with a pending error condition that
|
|
prevents the printer from going to the Online
|
|
state, the printer will remain in the Offline state;
|
|
<genErr> status is returned
|
|
|
|
Setting to eOffline has the following affect:
|
|
Printer will immediately go to or remain in the
|
|
Offline state; <noError> status is returned.
|
|
If pages are being printed, those pages will complete
|
|
with the printer in the Offline state.
|
|
|
|
Setting to eOfflineAtEndOfJob has the following
|
|
affect:
|
|
If not in a job or already in the Offline state, the
|
|
printer will immediately go to or remain in the
|
|
Offline state; <noError> status is returned.
|
|
If in a job and the current state is Online, the
|
|
printer will remain in the Online state, with the
|
|
value of this object as eOfflineAtEndOfJob, until the
|
|
end of the job; <noError> status is returned. At the end of
|
|
the job, the printer goes to the Offline state and the
|
|
value of this object becomes eOffline.
|
|
Setting this object to eOffline or eOnline before the
|
|
end of the job causes the action for that value to be
|
|
taken immediately."
|
|
::= { status-system 5 }
|
|
|
|
|
|
continue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInitiateAction(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A device can support a class of errors called
|
|
continuable errors. When a continuable error is
|
|
encountered, the device requires a continue event to
|
|
occur before the device will continue operation. One
|
|
continue event is setting the CONTINUE object to
|
|
eInitiateAction. Devices can support other continue
|
|
events, like auto-continue. A continue event causes the
|
|
continuable error to be acknowledged, thus allowing the
|
|
device to continue. Each device needs to list the
|
|
continuable errors. If the device doesn't currently
|
|
have an unacknowledged continuable error, the response
|
|
will contain <genErr>.
|
|
Additional information:
|
|
See the CLEARABLE-WARNING and AUTO-CONTINUE objects for the
|
|
errors that this object will clear."
|
|
::= { status-system 6 }
|
|
|
|
auto-continue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the device will automatically continue
|
|
after encountering a continuable error. If AUTO-
|
|
CONTINUE is set to eOn, the device will automatically
|
|
generate continue event to acknowledge continuable
|
|
errors. If AUTO-CONTINUE is set to eOff, then some
|
|
other continue event will have to acknowledge the
|
|
continuable error.
|
|
Additional information:
|
|
If this is set to eOn the device displays an
|
|
error message and goes offline for ten seconds. After ten seconds the
|
|
printer automatically returns to the online state.
|
|
|
|
If this is set to eOff then the device displays an error message and
|
|
goes offline. It remains offline until the operator presses the GO key or
|
|
until the CONTINUE object is set.
|
|
|
|
If the printer is not idle, the new value may not take effect
|
|
until a job boundary is reached. If a get is done on this object before
|
|
the job boundary is reached, the value last set will be returned."
|
|
::= { status-system 7 }
|
|
|
|
|
|
install-date OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Identifies the date that the device was installed. The format
|
|
of the string is 'YYYYMMDDHHmmZ'. Where:
|
|
YYYY is the year.
|
|
MM is the month (1-12).
|
|
DD is the day (1-31).
|
|
HH is the hour of the day (0-23).
|
|
mm are the minutes (0-59).
|
|
'Z' designates Greenwich Mean Time; if 'Z' not specified,
|
|
value is local time.
|
|
Device POS must specify the conditions for setting this
|
|
object.
|
|
Additional information:
|
|
Identifies the date that the device was installed. The
|
|
format of the string is 'YYYYMMDDHHmmZ'. Where:
|
|
YYYY is the year.
|
|
MM is the month (1-12).
|
|
DD is the day (1-31).
|
|
HH is the hour of the day (0-23).
|
|
mm are the minutes (0-59).
|
|
'Z' designates Greenwich Mean Time; if 'Z' not specified,
|
|
value is local time.
|
|
|
|
On Products without a real-time clock this
|
|
object has the inital value of 'INVALID'. While in
|
|
the invalid state the object may written to. Once the
|
|
initial install date has been written a new intall date
|
|
can not be written without resetting the object to 'INVALID'.
|
|
|
|
The behavior on products with real-time clocks is different.
|
|
The object is set to the initial real-time clock value, usually
|
|
this is '199000300000'. Manufacturing sets the real-time
|
|
clock to the correct date and sets the INSTALL-DATE to 'INVALID'.
|
|
Then when the customer turns on the printer for the first time
|
|
the install date is reset."
|
|
::= { status-system 8 }
|
|
|
|
user-nvram-reset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTrue(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting to eTrue causes all user NVRAM settings to
|
|
factory default settings. May also perform POWER-ON-
|
|
RESET functionality thus loosing print job data. The
|
|
POS will list which objects are effected by a user NVRAM
|
|
reset. Some items are NVRAM settings, but not user
|
|
controllable, so this action may not cause all of NVRAM
|
|
to be reset. Some examples of NVRAM settings that may
|
|
not be affected are page count, internally used pen
|
|
information, line configuration information, etc.
|
|
Additional information:
|
|
Setting to eTrue returns the NVRAM items listed
|
|
below to their factory default values. Performs
|
|
the same function as the 'MENU RESET' function
|
|
supported by the control panel except when printer
|
|
is in Offline state, setting this OID to eTrue will
|
|
not take the printer to the Online state.
|
|
DEFAULT-COPIES
|
|
DEFAULT-MEDIA-SIZE
|
|
DEFAULT-ORIENTATION
|
|
DEFAULT-LINES-PER-PAGE
|
|
DEFAULT-MANUAL-FEED
|
|
DEFAULT-RET
|
|
DEFAULT-PRINT-QUALITY
|
|
PCL-DEFAULT-FONT-SOURCE
|
|
PCL-DEFAULT-FONT-NUMBER
|
|
PCL-DEFAULT-FONT-HEIGHT
|
|
PCL-DEFAULT-FONT-WIDTH
|
|
PCL-DEFAULT-SYMBOL-SET
|
|
DEFAULT-VERTICAL-BLACK-RESOLUTION
|
|
DEFAULT-HORIZONTAL-BLACK-RESOLUTION
|
|
DEFAULT-PDL
|
|
CONTEXT-SENSITIVE-PDL-SELECTION
|
|
ENERGY-STAR
|
|
IO-TIMEOUT
|
|
DEFAULT-PAGE-PROTECT
|
|
POSTSCRIPT-JAM-RECOVERY (PostScript installed)
|
|
POSTSCRIPT-PRINT-ERRORS (PostScript installed)"
|
|
::= { status-system 12 }
|
|
|
|
total-ram-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies total amount of RAM, in bytes, available to
|
|
the controller for general computing."
|
|
::= { status-system 21 }
|
|
|
|
status-printer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if any of the sub-systems in the device in a
|
|
warning condition. A warning condition exists if the
|
|
sub-system is useable, but not at its highest state of
|
|
functionality."
|
|
::= { status-system 22 }
|
|
|
|
status-controller OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the hardware controller sub-system in a
|
|
warning condition."
|
|
::= { status-system 23 }
|
|
|
|
|
|
display-column-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of characters displayable on each
|
|
row of the printer's display."
|
|
::= { display-status 1 }
|
|
|
|
|
|
display-number-of-rows OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of rows displayable on the
|
|
printer's display."
|
|
::= { display-status 2 }
|
|
|
|
|
|
show-address OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eAuto(3),
|
|
eOff(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "If this object is set to eAuto, and the device has an IP
|
|
address, the IP address of the device will be shown with the
|
|
READY message. If this object is set to eOff, the IP address
|
|
will not be shown."
|
|
::= { display-status 3 }
|
|
|
|
|
|
status-msg-line1-part1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First part of the first line of the printer's status
|
|
message.
|
|
Additional information:
|
|
In the Offline state, device only returns
|
|
00 OFFLINE and not the actual content of control panel
|
|
display."
|
|
::= { status-message1 1 }
|
|
|
|
|
|
background-status-msg-line1-part1 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The string displayed on the device's front panel in
|
|
place of the printer's built-in background status
|
|
string. An example built-in background status string is
|
|
'00 READY'.
|
|
Additional information:
|
|
The display size for the LaserJet 4050 Series printers is 2 X 16.
|
|
The value of this object and the current value of
|
|
BACKGROUND-STATUS-MSG-LINE2-PART1 are displayed
|
|
together on the 2-line display, but they must
|
|
be set independently. If line 2 has been set, and the
|
|
next message to be displayed only requires line 1,
|
|
BACKGROUND-STATUS-MSG-LINE2-PART1 must be set to the
|
|
null string to clear it.
|
|
This object allows a message to be displayed when
|
|
it is the highest priority message. Setting this
|
|
object does not guarantee the message will be
|
|
displayed; and reading it returns the value last
|
|
written, not the currently displayed message (use
|
|
prtConsoleDisplayBufferText to read the
|
|
display).
|
|
The priority assigned for displaying this message
|
|
is one lower than the READY message. In other words,
|
|
the only message that can be replaced by these
|
|
objects is the READY message.
|
|
To clear the message, write a null string to both
|
|
this object and BACKGROUND-STATUS-MSG-LINE2-PART1."
|
|
::= { background-message1 1 }
|
|
|
|
|
|
background-status-msg-line2-part1 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The string displayed on the device's front panel in
|
|
place of the printer's built-in background status
|
|
string. An example built-in background status string is
|
|
'00 READY'.
|
|
Additional information:
|
|
See BACKGROUND-STATUS-MSG-LINE1-PART1"
|
|
::= { background-message2 1 }
|
|
|
|
error-log-clear OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eClearErrorLog(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object clears all the entries in the error
|
|
log sub-tree.
|
|
Additional information:
|
|
Setting this object removes all errors that have been
|
|
stored in the printer's non-volatile memory."
|
|
::= { status-system 38 }
|
|
|
|
|
|
localization-languages-supported OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of languages supported by the device. The
|
|
languages are primarily, but not limited to, two
|
|
character codes from ISO 639, each separated by a comma
|
|
character.
|
|
Additional information:
|
|
This string will always be in the Roman-8 character
|
|
set. See prtLocalizationLanguage for details about each language value."
|
|
::= { status-system 52 }
|
|
|
|
|
|
localization-countries-supported OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of countries supported by the device. The
|
|
countries are primarily, but not limited to, two
|
|
character codes from ISO 3166, each separated by a comma
|
|
character.
|
|
Additional information:
|
|
This string will always be in the Roman-8 character
|
|
set. See prtLocalizationCountry for details about each country value."
|
|
::= { status-system 53 }
|
|
|
|
|
|
control-panel-button-press OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eGoButton(1),
|
|
eMenuPlusButton(2),
|
|
eMenuMinusButton(3),
|
|
eItemPlusButton(4),
|
|
eItemMinusButton(5),
|
|
eValuePlusButton(6),
|
|
eValueMinusButton(7),
|
|
eSelectButton(8),
|
|
eCancelJobButton(9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing this object simulates pressing a button on the
|
|
control panel."
|
|
::= { status-system 60 }
|
|
|
|
|
|
model-number OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the device model number as listed in the HP
|
|
corporate price list (e.g. C2121A for DeskJet 500C).
|
|
The string is as specific as possible. Products should
|
|
note in POS if the model number on the CPL changes but
|
|
the device reports the previous model number. If the
|
|
model number changes based on the installed options, the
|
|
POS should indicate if only the base model number is
|
|
returned, or if the device senses the installed options
|
|
and returns the correct model number. If possible,
|
|
encode the model number in a symbol set (like Roman-8)
|
|
that matches the ASCII character set and limit the
|
|
characters used to ASCII characters.
|
|
Additional information:
|
|
The value of this object does not change based on
|
|
the installed options."
|
|
::= { id 1 }
|
|
|
|
model-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the device model name (e.g. ''DeskJet 1200C''). The
|
|
string is as specific as possible. Capitalization and spacing
|
|
should match family naming conventions. Products should note in
|
|
POS if the model name on the HP corporate price list changes
|
|
but the device reports the previous device name. If the model
|
|
name changes based on the installed options, the POS should
|
|
indicate if only the base model name is returned, or if the
|
|
device senses the installed options and returns the correct
|
|
model name. If possible, encode the model name in a symbol set
|
|
(like Roman-8) that matches the ASCII character set and limit
|
|
the characters used to ASCII characters."
|
|
::= { id 2 }
|
|
|
|
serial-number OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the serial number for the device. If the
|
|
SERIAL-NUMBER object is set by the user, then setting
|
|
the object does not need to be protected. If the
|
|
SERIAL-NUMBER object is set at the factory, then the
|
|
SERVICE-PASSWORD object must be set correctly before the
|
|
SERIAL-NUMBER object is writable. If this is a writable
|
|
object, the POS should indicate the maximum supported
|
|
string length. If possible, encode the serial number in
|
|
a symbol set (like Roman-8) that matches the ASCII
|
|
character set and limit the characters used to ASCII
|
|
characters.
|
|
Additional information:
|
|
This value IS AFFECTED BY NVRAM resets, it is set to the
|
|
default value of XXXXXXXXXX, when a NVRAM init is done."
|
|
::= { id 3 }
|
|
|
|
|
|
fw-rom-datecode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the base system firmware date code. The date
|
|
code will be encoded in the yyyymmdd format. There may
|
|
be several versions of the base system firmware. The
|
|
date code associated with the version of the base system
|
|
firmware that is being used is reported. There may be
|
|
other date code objects for other specific modules such
|
|
as fonts, localization modules, etc.; these other
|
|
datecode objects are device specific."
|
|
::= { id 5 }
|
|
|
|
fw-rom-revision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies the system code firmware ROM revision code. The
|
|
format for a revision is major_revision.minor_revision. There
|
|
may be other ROM revision code objects for other specific ROMs
|
|
such as font ROMs, localization ROMs, etc; these other ROM
|
|
revision code objects are device specific."
|
|
::= { id 6 }
|
|
|
|
fax-local-phone-num OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "CCITT sender's station id (ex. 08-396-4122)."
|
|
::= { id 8 }
|
|
|
|
|
|
fax-station-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "name for the fax device (ex. HP R&D)."
|
|
::= { id 9 }
|
|
|
|
|
|
device-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User defined device name. The POS should indicate the
|
|
maximum supported string length. If the user entered
|
|
string is too long, the device will store as much as
|
|
possible and will return the <noError>.
|
|
|
|
Additional information:
|
|
The maximum supported string length is 32
|
|
characters. If the user entered string is too long,
|
|
the device will store the first 32 characters and will
|
|
return the <noError> status."
|
|
::= { id 10 }
|
|
|
|
device-location OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User defined device location. The POS should indicate
|
|
the maximum supported string length. If the user
|
|
entered string is too long, the device will store as
|
|
much as possible and will return the <noError>.
|
|
|
|
Additional information:
|
|
The maximum supported string length is 16
|
|
characters. If the user entered string is too long,
|
|
the device will store the first 16 characters and will
|
|
return the <noError> status."
|
|
::= { id 11 }
|
|
|
|
|
|
asset-number OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User defined asset number. The POS should indicate the
|
|
maximum supported string length. If the user entered
|
|
string is too long, the device will store as much as
|
|
possible and will return the <noError>.
|
|
|
|
Additional information:
|
|
The maximum supported string length is 8
|
|
characters. If the user entered string is too long,
|
|
the device will store the first 8 characters and will
|
|
return the <noError> status."
|
|
::= { id 12 }
|
|
|
|
system-contact OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User defined string containing the name of the person or
|
|
group that is responsible for the device. The POS
|
|
should indicate the maximum supported string length. If
|
|
the user entered string is too long, the device will
|
|
store as much as possible and will return the
|
|
<noError>.
|
|
Additional information:
|
|
User defined system contact. The maximum
|
|
supported string length is 16 characters. If the user
|
|
entered string is too long, the device will store as
|
|
much as possible and will return the
|
|
<noError> status."
|
|
::= { id 13 }
|
|
|
|
fax-line-interface-unit-id OBJECT-TYPE
|
|
SYNTAX INTEGER(0..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The fax device line interface unit (LIU) identifier. The LIU
|
|
number identifies the telephone system electrical
|
|
characteristics supported by this device.
|
|
Additional information:
|
|
In this LaserJet MFP this value is stored in 3 bits on the
|
|
LIU."
|
|
::= { id 18 }
|
|
|
|
|
|
at1-model-number OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the AT model number. If the disk was
|
|
manufactured by HP, then the model number is the one
|
|
listed in the HP corporate price list. If possible,
|
|
encode the model number in a symbol set (like Roman-8)
|
|
that matches the ASCII character set and limit the
|
|
characters used to ASCII characters.
|
|
Additional information:
|
|
The model number is obtained from the disk
|
|
using the IDE (Intelligent Drive Electronics)
|
|
Identify command. This objects is only supported
|
|
if a disk is installed. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no disk installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no disk installed."
|
|
::= { at1 1 }
|
|
|
|
|
|
at1-model-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying the AT storage
|
|
device. Example: C3014A
|
|
Additional information:
|
|
The product information is obtained from the
|
|
disk using the IDE (Intelligent Drive Electronics)
|
|
Identify command. This objects is only supported
|
|
if a disk is installed. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no disk installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no disk installed."
|
|
::= { at1 2 }
|
|
|
|
|
|
at1-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of this
|
|
particular AT. May include serial number and firmware
|
|
revision.
|
|
Additional information:
|
|
Returns the model number, serial number, and
|
|
firmware revision of the installed disk. This
|
|
information is obtained from the disk using the
|
|
IDE (Intelligent Drive Electronics) Identify
|
|
command. Example: HP C3014A JP932412W9 K2A4A059.
|
|
This objects is only supported if a disk is installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no disk
|
|
installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no disk installed."
|
|
::= { at1 3 }
|
|
|
|
|
|
at1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eDiskDrive(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
this particular AT interface. See SIMM1-TYPE for an
|
|
explanation of the enumerations.
|
|
Additional information:
|
|
eEmpty means the device did not detect any AT.
|
|
eDiskDrive means the AT contains a disk drive."
|
|
::= { at1 4 }
|
|
|
|
|
|
at1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the installed
|
|
option. See SIMM1-CAPACITY for an explanation of the
|
|
meaning of the value of this object.
|
|
Additional information:
|
|
This object contains the size, in bytes, of
|
|
the installed disk option. This objects is only
|
|
supported if a disk is installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no disk
|
|
installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no disk installed."
|
|
::= { at1 5 }
|
|
|
|
|
|
simm1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5),
|
|
eFlashMemory(7),
|
|
eRamRom(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 1.
|
|
eEmpty means the device did not detect any option
|
|
installed in the interface slot.
|
|
eUnknown means the device doesn't recognize the
|
|
installed option.
|
|
eUnSupported means the device recognizes the installed
|
|
option, but does not support the option.
|
|
eReadOnlyMemory means the installed option contains
|
|
ROM Ics.
|
|
eVolatileRandomAccessMemory means the installed option
|
|
contains RAM ICs that loose data when the power is
|
|
turned off.
|
|
eNonVolatileRandomAccessMemory means that the
|
|
installed option contains RAM ICs that do not loose data
|
|
when the power is turned off.
|
|
eFlashMemory means that the installed option contains
|
|
a type of non-volatile RAM that needs to be erased
|
|
before it can be written.
|
|
eDiskDrive means the installed option contains a disk
|
|
drive. eRamRom means the installed option contains both
|
|
volatile random access memory and read only memory.
|
|
eInputPHD means the installed option is an input paper
|
|
handling device.
|
|
eOutputPHD means the installed option is an output
|
|
paper handling device.
|
|
eIOCard means the installed option is an I/O card.
|
|
Additional information:
|
|
This object is used for describing DIMMs instead
|
|
of SIMMs on LaserJet 4050 Series. eRamRom is used to denote LaserJet 4050 Series's combo simm."
|
|
::= { simm1 4 }
|
|
|
|
|
|
simm1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 1. The capacity is dependent on
|
|
the type of option, as indicated by the SIMM1-TYPE
|
|
object. This object has no meaning if the installed
|
|
option type is eUnknown or eReadOnlyMemory. This object
|
|
contains the size, in bytes, if the installed option
|
|
type is eVolatileRandomAccessMemory,
|
|
eNonVolatileRandomAccessMemory, eFlashMemory, or
|
|
eDiskDrive. If the type of the installed option is
|
|
eRamRom, this object contains the size, in bytes, of the
|
|
random access memory. If the type of the installed
|
|
option is eInputPHD, the capacity indicates the number
|
|
of input trays supported by the installed option. If
|
|
the type of the installed option is eOutputPHD, the
|
|
capacity indicates the number of output bins supported
|
|
by the installed option. If the type of the installed
|
|
option is eIOCard, the capacity indicates the number of
|
|
logical I/O ports supported by the I/O card.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM1-TYPE type is
|
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
|
For eRamRom only the size of the Ram portion of the SIMM
|
|
is returned."
|
|
::= { simm1 5 }
|
|
|
|
|
|
simm2-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5),
|
|
eFlashMemory(7),
|
|
eRamRom(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 2. See SIMM1-TYPE for a description.
|
|
Additional information:
|
|
This object is used for describing DIMMs instead
|
|
of SIMMs on LaserJet 4050 Series. eRamRom is used to denote LaserJet 4050 Series's combo simm."
|
|
::= { simm2 4 }
|
|
|
|
|
|
simm2-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 2. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
This object is used for describing DIMMs instead
|
|
of SIMMs on LaserJet 4050 Series. Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM2-TYPE type is
|
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
|
For eRamRom only the size of the Ram portion of the
|
|
SIMM is returned."
|
|
::= { simm2 5 }
|
|
|
|
|
|
simm3-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5),
|
|
eFlashMemory(7),
|
|
eRamRom(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 3. See SIMM1-TYPE for a description."
|
|
::= { simm3 4 }
|
|
|
|
|
|
simm3-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 3. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
This object is used for describing DIMMs instead
|
|
of SIMMs on LaserJet 4050 Series. Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM3-TYPE type is
|
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
|
For eRamRom only the size of the Ram portion of the
|
|
simm is returned."
|
|
::= { simm3 5 }
|
|
|
|
simm4-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 4. See SIMM1-TYPE for a description."
|
|
::= { simm4 4 }
|
|
|
|
|
|
simm4-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 4. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM4-TYPE type is
|
|
eVolatileRandomAccessMemory."
|
|
::= { simm4 5 }
|
|
|
|
simm5-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 5. See SIMM1-TYPE for a description."
|
|
::= { simm5 4 }
|
|
|
|
|
|
simm5-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 5. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM5-TYPE type is
|
|
eVolatileRandomAccessMemory."
|
|
::= { simm5 5 }
|
|
|
|
|
|
simm6-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 6. See SIMM1-TYPE for a description."
|
|
::= { simm6 4 }
|
|
|
|
|
|
simm6-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 6. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM6-TYPE type is
|
|
eVolatileRandomAccessMemory."
|
|
::= { simm6 5 }
|
|
|
|
|
|
simm7-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 7. See SIMM1-TYPE for a description."
|
|
::= { simm7 4 }
|
|
|
|
|
|
simm7-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 7. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM7-TYPE type is
|
|
eVolatileRandomAccessMemory."
|
|
::= { simm7 5 }
|
|
|
|
|
|
simm8-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 8. See SIMM1-TYPE for a description."
|
|
::= { simm8 4 }
|
|
|
|
|
|
simm8-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 8. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM8-TYPE type is
|
|
eVolatileRandomAccessMemory."
|
|
::= { simm8 5 }
|
|
|
|
|
|
usb-product-id OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Returns the Product ID of a connected USB device as defined in
|
|
the Standard Device Descriptor of the Universal Serial Bus
|
|
Specification Version 2.0. The value will be in the range
|
|
0..65535."
|
|
::= { usb 5 }
|
|
|
|
|
|
self-test OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNotInASelfTest(1),
|
|
eNonDestructiveSelfTest(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing this object allows a device self test to be
|
|
started. Reading this object provides an indication
|
|
what self-test is currently executing, if any. Actual
|
|
self-test operation is device specific. A self test may
|
|
not be allowed at any arbitrary time. If the device
|
|
supports the requested self test, but can not start the
|
|
execution of the self test when requested, the device
|
|
will respond with <genErr>. If
|
|
a non-destructive self test is being started, the device
|
|
will generate a response before the self test is
|
|
completed.
|
|
RECOMMENDATION: If the device is ready (i.e. the NOT-
|
|
READY-PRINTER object does not contain any items, except
|
|
maybe being off-line) and is idle (i.e. the NOT-IDLE
|
|
object does not contain any items), this request should
|
|
always succeed. This provides a mechanism for driver
|
|
writers to always determine if the action will succeed
|
|
or not.
|
|
Additional information:
|
|
The eNonDestructiveSelfTest performs limited
|
|
testing on the printer and its attached paper handling
|
|
devices. After the self-test is complete a
|
|
configuration page is printed. The recommended
|
|
way to cause a configuration page to be printed is to
|
|
use the PRINT-INTERNAL-PAGE object.
|
|
|
|
Setting this object to eNonDestructiveSelfTest results in a status of <noError>
|
|
and a value of eNonDestructiveSelfTest being returned.
|
|
If the printer is not idle (whether printing an external job or printing
|
|
an internal page), this action will be delayed until the next job boundary.
|
|
|
|
See the PRINT-INTERNAL-PAGE object for more details."
|
|
::= { test 1 }
|
|
|
|
|
|
print-internal-page OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNotPrintingAnInternalPage(1),
|
|
ePrintingAnUnknownInternalPage(2),
|
|
eDeviceDemoPage1ConfigurationPage(3),
|
|
eDeviceDemoPage5ErrorLog(7),
|
|
eDeviceDemoPage6FileSystemDirectoryListing(8),
|
|
eDeviceDemoPage7MenuMap(9),
|
|
eDeviceUsagePage(10),
|
|
ePCLFontList1(350),
|
|
ePSFontList(450)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing this object to a value other than
|
|
eNotPrintingAnInternalPage causes the device to attempt
|
|
to print an internally generated page. Reading this
|
|
object provides an indication what internally generated
|
|
page is currently being printed, if any. The actual
|
|
page is device specific. Some devices may support
|
|
continuously printing an internally generated page.
|
|
Setting this object to eNotPrintingAnInternalPage
|
|
terminates continuously printing internally generated
|
|
pages. An internally generated page may not be allowed
|
|
to be printed at any arbitrary time; under what
|
|
conditions it will succeed or fail is device specific.
|
|
If the device supports the requested page, but can not
|
|
start printing the page when requested, the device will
|
|
respond with <genErr>.
|
|
RECOMMENDATION: If the device is ready (i.e. the NOT-
|
|
READY-PRINTER object does not contain any items, except
|
|
maybe being off-line) and is idle (i.e. the NOT-IDLE
|
|
object does not contain any items), this request should
|
|
always succeed. This provides a mechanism for driver
|
|
writers to always determine if the action will succeed
|
|
or not.
|
|
Additional information:
|
|
Previous products used
|
|
ePCLDemoPage1ConfigurationPage(300) for the
|
|
Configuration or Self Test page. This product uses
|
|
eDeviceDemoPage1ConfigurationPage(3).
|
|
|
|
LaserJet 4050 Series does not support continuously printing a demo page.
|
|
|
|
When this object is set to a valid value, the status returned is <noError>
|
|
and the value returned is ePrintingAnUnknownInternalPage. If the printer
|
|
is idle, the page will be printed immediately. If the printer is
|
|
currently printing another job, the internal page requested will not print
|
|
until that job is finished.
|
|
|
|
Setting this object to a valid value causes the
|
|
desired page to be formatted and put in the printer's
|
|
print queue. While the page is being formatted a get on this object will
|
|
return the value ePrintingAnUnknownInternalPage. Once the page (or pages)
|
|
is finished being formatted, this object returns a value of
|
|
eNotPrintingAnInternalPage, even though the page may not have finished
|
|
being printed.
|
|
|
|
Setting this object multiple times will queue up the requests, but only
|
|
a limited number will be queued. Once the queue is full, additional
|
|
requests will be ignored."
|
|
::= { test 2 }
|
|
|
|
|
|
clearable-warning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOn(2),
|
|
eJob(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or controls how the device will track clearable
|
|
warnings. A clearable warning indicates a transient
|
|
event in the device. The device will continue after the
|
|
transient event occurs. If CLEARABLE-WARNING is eOff,
|
|
the device does not track clearable warnings. If
|
|
CLEARABLE-WARNING is eOn, all clearable warnings will be
|
|
tracked until cleared (acknowledged). If CLEARABLE-
|
|
WARNING is eJob, a clearable warning generated due to an
|
|
event that occurs because of the print job being
|
|
processed will be automatically cleared when the device
|
|
has finished processing the job. Example clearable
|
|
warning events include the device altering resolution or
|
|
page protection due to memory constraints. The POS will
|
|
document what transient events are treated as clearable
|
|
warnings.
|
|
Additional information:
|
|
If set to eOn, the warning is displayed until the GO key
|
|
is pressed or the CONTINUE object is set.
|
|
|
|
If set to eJob, the warning is displayed until the end of the job in which
|
|
it was generated."
|
|
::= { settings-job 1 }
|
|
|
|
|
|
cancel-job OBJECT-TYPE
|
|
SYNTAX INTEGER(0..32767)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cancels the print job whose ID matches the value written
|
|
to the CANCEL-JOB object. The host first learns the job
|
|
ID using the CURRENT-JOB-PARSING-ID command. If the
|
|
printer has completely processed the job, the printer
|
|
responds with <badValue>. If the
|
|
value of the CURRENT-JOB-PARSING-ID is smaller than the
|
|
value written to the CANCEL-JOB object, then the printer
|
|
responds with <badValue>. When
|
|
read, returns the value of the last job ID what was
|
|
canceled, or -1 to indicate no job has been canceled.
|
|
Additional information:
|
|
If the value written matches the ID of a job that is
|
|
currently being canceled (for any reason),
|
|
the printer responds with <noError>.
|
|
LaserJet 4050 Series uses job ID's in the range of 0..32767.
|
|
Because the ID number can wrap to zero,
|
|
CURRENT-JOB-PARSING-ID may be smaller than the value
|
|
written to this object; when this occurs, no error
|
|
will result as long as the ID is for a currently
|
|
processing job. This object is write only, so the
|
|
comment in the general description stating the
|
|
job ID or -1 will be returned on a read does not
|
|
apply."
|
|
::= { settings-job 2 }
|
|
|
|
|
|
faxjob-action OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePrintFaxToPrinter(1),
|
|
eDeleteFaxFromMemory(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Permits host to specify an action to be applied with a
|
|
particular fax."
|
|
::= { settings-fax-job 1 }
|
|
|
|
|
|
faxjob-action-id OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the fax job identification of the fax to be
|
|
acted upon by the action specified by the object FAXJOB-
|
|
ACTION."
|
|
::= { settings-fax-job 2 }
|
|
|
|
|
|
faxjob-tx-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eSrcHostOnly(2),
|
|
eSrcScannerOnly(5),
|
|
eSrcHostToMemoryOnly(9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates sources of the fax image for transmission.
|
|
Also specifies the temporal order of the data sources.
|
|
eSrcHostOnly - The fax document images will be wholly
|
|
downloaded from the host.
|
|
eSrcScannerOnly - The fax document images originate
|
|
wholly from the device scanner/ADF subsystem.
|
|
eSrcHostThenScanner - The fax document is composed of
|
|
images downloaded from the host and pages from the
|
|
scanner/ADF subsystem. The host downloaded pages will
|
|
be faxed first, followed by the pages in the
|
|
scanner/ADF.
|
|
eSrcScannerThenHost - The fax document is composed of
|
|
pages in the scanner/ADF and the images downloaded from
|
|
the host. The document in the ADF is faxed first,
|
|
followed by the pages downloaded from the host.
|
|
wSrcHostThenMemory - The fax document is composed of
|
|
pages downloaded from the host and images already stored
|
|
within the device. The fax transmission will contain
|
|
the host downloaded pages followed by the images in the
|
|
device memory.
|
|
eSrcHostToMemoryOnly - Permits fax images to be
|
|
downloaded into device memory for later use with
|
|
eSrcHostThenMemory.
|
|
Additional information:
|
|
GECKO NOTE: eSrcHostToMemoryOnly is included for
|
|
development and testing only. eSrcHostToMemoryOnly will
|
|
not be an allowed value for this object in the released
|
|
product."
|
|
::= { settings-fax-job 3 }
|
|
|
|
|
|
faxjob-print-duplex-mode-select OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDuplexerDisabled(1),
|
|
eDuplexerEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Allows the host to enable or disable duplex printing on a
|
|
device for the next fax job.
|
|
Additional information:
|
|
Allows the host to enable or disable duplex printing on a
|
|
device for the next fax job."
|
|
::= { settings-fax-job 5 }
|
|
|
|
|
|
faxjob-download-id OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the device assigned job identification for the
|
|
current fax downloading job. The job ID is
|
|
monotonically increasing number. The job ID may be
|
|
reset to zero or may roll over to zero after reaching
|
|
some maximum. The maximum value before the rollover
|
|
should be stated in the POS.
|
|
Additional information:
|
|
The maximum value before this object rolls over
|
|
to 0 is 2,147,483,648. Behavior of this object once
|
|
the value rolls over to 0 is not specified."
|
|
::= { status-fax-job 1 }
|
|
|
|
|
|
faxjob-rx-id OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the device assigned job identification for the
|
|
currently fax reception job. The job ID is
|
|
monotonically increasing number. The job ID may be
|
|
reset to zero or may roll over to zero after reaching
|
|
some maximum. The maximum value before the rollover
|
|
should be stated in the POS.
|
|
Additional information:
|
|
The maximum value before this object rolls over
|
|
to 0 is 2,147,483,648. Behavior of this object once
|
|
the value rolls over to 0 is not specified."
|
|
::= { status-fax-job 2 }
|
|
|
|
|
|
faxjob-tx-id OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the device assigned job identification for the
|
|
current fax transmission job. The job ID is
|
|
monotonically increasing number. The job ID may be
|
|
reset to zero or may roll over to zero after reaching
|
|
some maximum. The maximum value before the rollover
|
|
should be stated in the POS.
|
|
Additional information:
|
|
The maximum value before this object rolls over
|
|
to 0 is 2,147,483,648. Behavior of this object once
|
|
the value rolls over to 0 is not specified."
|
|
::= { status-fax-job 3 }
|
|
|
|
|
|
faxjob-upload-id OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the device assigned job identification for the
|
|
current fax upload job. The job ID is monotonically
|
|
increasing number. The job ID may be reset to zero or
|
|
may roll over to zero after reaching some maximum. The
|
|
maximum value before the rollover should be stated in
|
|
the POS.
|
|
Additional information:
|
|
The maximum value before this object rolls over
|
|
to 0 is 2,147,483,648. Behavior of this object once
|
|
the value rolls over to 0 is not specified."
|
|
::= { status-fax-job 4 }
|
|
|
|
|
|
faxjob-rx-status-1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFaxRxIdle(1),
|
|
eFaxRxRinging(2),
|
|
eFaxRxAnswering(3),
|
|
eFaxRxReceiving(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of receiving fax session 1."
|
|
::= { faxjob-rx-status 1 }
|
|
|
|
|
|
faxjob-tx-status-1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFaxTxIdle(1),
|
|
eFaxTxDialing(2),
|
|
eFaxTxConnecting(3),
|
|
eFaxTxTransmitting(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of sending fax session 1."
|
|
::= { faxjob-tx-status 1 }
|
|
|
|
|
|
faxjob-tx-error-1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error status of the fax reception session 1.
|
|
Additional information:
|
|
Error status of the fax transmission session 1."
|
|
::= { faxjob-tx-error 1 }
|
|
|
|
|
|
faxjob-tx-current-page-1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The page number of the fax page currently being
|
|
transmitted via send fax session 1. Starts with page
|
|
number 1."
|
|
::= { faxjob-tx-current-page 1 }
|
|
|
|
|
|
faxjob-rx-current-page-1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The page number of the fax page currently being received
|
|
via fax reception session 1. Starts with page number
|
|
1."
|
|
::= { faxjob-rx-current-page 1 }
|
|
|
|
|
|
faxjob-rx-duration-1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represent the number of seconds of phone-connect time
|
|
for a fax reception session 1."
|
|
::= { faxjob-rx-duration 1 }
|
|
|
|
|
|
faxjob-tx-duration-1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represent the number of seconds of phone-connect time
|
|
for send fax session 1."
|
|
::= { faxjob-tx-duration 1 }
|
|
|
|
|
|
fax-log-action OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eIdle(1),
|
|
eClear(2),
|
|
ePrintLatest(3),
|
|
ePrintAll(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides applications with the ability to clear or print
|
|
the fax transaction log.
|
|
eIdle - no action is occurring on the fax log.
|
|
eClear - clear the fax log.
|
|
ePrintLatest - print the latest entry in the fax log.
|
|
ePrintAll - print all the entries in the fax log.
|
|
When this object is set to a non-eIdle value by an
|
|
application, the given action starts. When the action
|
|
is complete, this object is changed back to eIdle by the
|
|
device. A host's request to write this object will be
|
|
rejected when the object is not eIdle. When eIdle, the
|
|
host may set the object to any value (including eIdle)."
|
|
::= { settings-faxlog 1 }
|
|
|
|
|
|
fax-log-reporting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNever(1),
|
|
eErrorOnly(2),
|
|
eSendOnly(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies when fax transaction logs are to be printed."
|
|
::= { settings-faxlog 2 }
|
|
|
|
|
|
fax-dial-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eToneDial(1),
|
|
ePulseDial(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device should use DTMF dialing if eToneDial, pulse dial
|
|
if ePulseDial."
|
|
::= { dial-all-lines 1 }
|
|
|
|
|
|
device-redial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device to permit redial upon detecting certain error
|
|
conditions."
|
|
::= { dial-all-lines 2 }
|
|
|
|
|
|
fax-answer-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eManualAnswer(1),
|
|
eFaxAnswer(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the answering-priority when using a shared voice
|
|
line.
|
|
eManualAnswer - Device will not automatically answer
|
|
the phone. User must answer and push START button.
|
|
eFaxAnswer - Device should assume call is fax, send
|
|
CED immediately upon answering.
|
|
eTadAnswer - (Telephone Answering Device Mode) Device
|
|
allows downstream TAD to answer but device will
|
|
eavesdrop for fax CNG signal. If a CNG detected, cut
|
|
off the downstream device, send CED. Do nothing if CNG
|
|
not detected."
|
|
::= { answer-all-lines 1 }
|
|
|
|
|
|
fax-num-rings-pickup OBJECT-TYPE
|
|
SYNTAX INTEGER(1..6)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of rings before the fax device answers the phone
|
|
if FAX-ANSWER-MODE is not set to MANUAL-MODE."
|
|
::= { answer-all-lines 2 }
|
|
|
|
|
|
device-ring-type-pickup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device to answer the incoming call based on detecting
|
|
the the specified type of telephone ring."
|
|
::= { answer-all-lines 3 }
|
|
|
|
|
|
fax-receive-stamping-enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether or not incoming pages of a fax will be
|
|
stamped upon receipt. Content of the stamp is device-
|
|
specific but may include such information as date,
|
|
time, fax station name, and page number. When this
|
|
object is set to eEnabled each page of an incoming fax
|
|
is stamped by the device. When this object is set to
|
|
eDisabled incoming fax pages are not stamped.
|
|
Additional information:
|
|
When this object is set to eEnabled each page of an
|
|
incoming fax is stamped with the date, time, fax station
|
|
name, and page number. When this object is set to
|
|
eDisabled incoming fax pages are not stamped.
|
|
//
|
|
The received fax page will be scaled down 0.03% to
|
|
accomodate the header. No header will be printed on
|
|
page 2 of paginated output."
|
|
::= { settings-fax-receive 1 }
|
|
|
|
|
|
not-ready-fax-receive OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the receiving fax sub-system in the device
|
|
is not ready. If there are no items in the collection
|
|
(i.e. no bits are set), then the receiving fax sub-
|
|
system is ready. If there is an item present, then the
|
|
item indicates what is causing the receiving fax sub-
|
|
system to be not ready."
|
|
::= { status-fax-receive 1 }
|
|
|
|
|
|
fax-rxscale OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received faxes are to be printed at a reduced scale
|
|
percentage. Value of 0 indicates auto-scaled printing
|
|
based on the length of the received fax image and the
|
|
length of the paper."
|
|
::= { settings-fax-proc-sub 1 }
|
|
|
|
|
|
fax-noise-volume OBJECT-TYPE
|
|
SYNTAX INTEGER(0..200)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Range is 0..100, where 0 = quietest possible, and 100 =
|
|
loudest possible. A device shall divide this value into
|
|
ranges corresponding to the possible volumes.
|
|
Additional information:
|
|
For HP Laserjet 3200 the range is 0..200, where 0=off (silent),
|
|
96=soft, 160=medium, and 200=loud.
|
|
|
|
For HP Laserjet 3200 this object refers to the line monitor
|
|
noise volume. The decimal values above correspond
|
|
to the hex values the object gets set to."
|
|
::= { settings-fax-proc-sub 3 }
|
|
|
|
|
|
fax-download OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFaxDownloadIdle(1),
|
|
eFaxDownloadStart(2),
|
|
eFaxDownloadActive(3),
|
|
eFaxDownloadAborted(4),
|
|
eFaxDownloadDone(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Note: Changed enumeration values in a non-backwards
|
|
manner in version 4.7. Handshake mechanism between host
|
|
and device to initiate and coordinate the download of
|
|
fax image data to be transmitted by the device fax
|
|
modem. This object serves both as an indicator of fax
|
|
download activity as well as a trigger for the host to
|
|
alter fax download progress. This object has been
|
|
redefined to track only the download acpect of the fax
|
|
transmission.
|
|
eFaxDownloadIdle - indicates no fax download activity
|
|
is occurring. Device powers up in this state but will
|
|
otherwise never transition to this state of its own
|
|
accord. Host setting to eFaxDownloadIdle while object
|
|
is in eFaxDownloadActive will cause download activity to
|
|
be prematurely terminated. Host setting to this state
|
|
resets the handshake mechanism to permit a another fax
|
|
download activity to be initiated.
|
|
eFaxDownloadStart - indicates the host requests to
|
|
commence a download session for sending a fax. This
|
|
state is host settable only from eFaxDownloadIdle.
|
|
Device will never transition to this state of its own
|
|
accord.
|
|
eFaxDownloadActive - indicates a fax download is
|
|
occurring. This state is not host settable. Device
|
|
will transition to this state from eFaxDownloadStart as
|
|
a positive response for host to commence download of fax
|
|
data. This state is not host settable. The object
|
|
FAXJOB-DOWNLOAD-ID now contains the job ID to be used to
|
|
track the progress of this fax job.
|
|
eFaxDownloadAborted - indicates the fax download
|
|
activity has been prematurely terminated by the device
|
|
due to some error. Object FAX-DOWNLOAD-ERROR contains
|
|
the error reason for the premature session termination.
|
|
This state is device settable from eFaxDownloadStart or
|
|
eFaxDownloadActive. This state is not host settable.
|
|
If modem transmission of fax data has started for this
|
|
download, the fax session will also be aborted.
|
|
eFaxDownloadDone - indicates the fax download activity
|
|
has reached a successful termination in that the device
|
|
has accepted all the download data from the host. This
|
|
state is only settable by the device from
|
|
eFaxDownloadActive. This state is not host settable.
|
|
This state does not indicate the progress of the modem
|
|
transmission of the downloaded fax data. Host should
|
|
transition from this state to eFaxDownloadIdle in order
|
|
to reset the handshake mechanism for subsequent
|
|
download."
|
|
::= { settings-fax-proc-sub 6 }
|
|
|
|
|
|
fax-silent-detection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When enabled, this object causes the FAX machine to
|
|
assume that the caller is a FAX even though the line has
|
|
remained silent for a time (i.e., no CNG detected).
|
|
When disabled, a CNG is required of the caller."
|
|
::= { settings-fax-proc-sub 7 }
|
|
|
|
|
|
fax-ring-enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the phone line rings, this object determines
|
|
whether an audible ring shall be emitted."
|
|
::= { settings-fax-proc-sub 8 }
|
|
|
|
|
|
fax-country OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eChina(6),
|
|
eMexicoAndLatinAmerica(13),
|
|
eCanadaFrench(14),
|
|
eUnitedStatesAndCanadaEnglish(15),
|
|
eNewZealand(19),
|
|
eIsrael(21),
|
|
eAustralia(23),
|
|
eMalaysia(27),
|
|
eHongKong(29),
|
|
eSingapore(30),
|
|
eUnitedKingdom(31),
|
|
eAustria(34),
|
|
eNetherlands(35),
|
|
eSwitzerlandFrench(37),
|
|
eGermany(39),
|
|
eDenmark(40),
|
|
eSweden(41),
|
|
eNorway(43),
|
|
eIreland(44),
|
|
eBelgium(45),
|
|
eFinland(46),
|
|
eFrance(47),
|
|
eItaly(51),
|
|
eSpain(55),
|
|
ePoland(56),
|
|
eHungary(62),
|
|
eUkraine(63),
|
|
eRussia(64)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Note: Non-backwards compatible change make in version
|
|
4.7. Returns which country the telephone-electronics
|
|
(LIU) is configured for.
|
|
|
|
If this object is implemented with an access of read-write
|
|
the device POS will specify what occurs when this object
|
|
is written.
|
|
Additional information:
|
|
GECKO NOTE: Is enumeration 37 (eSwitzerlandFrench)
|
|
the correct setting for Switzerland? The mib also
|
|
provides the following options:
|
|
eSwitzerland(36)
|
|
eSwitzerlandGerman(36)
|
|
eSwitzerlandItalian(38)"
|
|
::= { settings-fax-proc-sub 9 }
|
|
|
|
|
|
fax-tx-phone-number OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Phone number about to be dialed."
|
|
::= { settings-fax-proc-sub 10 }
|
|
|
|
|
|
fax-redial-time OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds one must wait between the current
|
|
redial (set by FAX-WHICH-REDIAL) and any prior dialing."
|
|
::= { settings-fax-proc-sub 14 }
|
|
|
|
|
|
fax-pstn-access-code OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The code used within a PBX to get access to an outside
|
|
PSTN line. Typically this is ''9''."
|
|
::= { settings-fax-proc-sub 18 }
|
|
|
|
|
|
fax-rx-disposition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePrintOnly(1),
|
|
eUploadOnly(2),
|
|
eUploadElsePrint(4),
|
|
eForwardElsePrint(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates what is to be done with the incoming fax
|
|
call.
|
|
ePrintOnly - New fax arrivals only go to the printer.
|
|
If printer becomes unavailable, the fax is stored in
|
|
device memory until the printer becomes available. If
|
|
device memory becomes full, no subsequent calls will be
|
|
answered. If power is cycled on the device, the user
|
|
must be informed of any lost faxes. If faxes are saved
|
|
in non-volatile memory, then they will be printed upon
|
|
successful power-up.
|
|
eUploadOnly - New fax can only be uploaded to the
|
|
host. If host becomes unavailable, the fax is stored in
|
|
device memory until host becomes available again to
|
|
upload. If device memory becomes full, no subsequent
|
|
calls will be answered. If power is cycled on the
|
|
device, the user must be informed of any lost faxes. If
|
|
faxes are saved in non-volatile device memory, the host
|
|
must be informed of a need to upload saved faxes upon
|
|
successful power up.
|
|
eUploadAndPrint - Received faxes are to be printed and
|
|
also uploaded to the host. The fax is stored in device
|
|
memory until it has been printed and uploaded. If
|
|
device memory becomes full, no subsequent calls will be
|
|
answered. If power is cycled on the device, the user
|
|
must be informed of any lost faxes. If faxes were saved
|
|
into non-volatile memory, then faxes must be printed and
|
|
uploaded before erasure from device memory.
|
|
eUploadElsePrint - Received faxes are to be uploaded
|
|
if host is available, otherwise the fax is printed.
|
|
During an upload, if the host becomes unavailable, the
|
|
remainder of the fax is printed. Once the host is
|
|
detected to be unavailable, the object will transition
|
|
to ePrintOnly. Refer to fax reception behavior for
|
|
ePrintOnly.
|
|
ePrintElseUpload - Received faxes are to be printed.
|
|
If printer is unavailable, the fax will be uploaded. If
|
|
printer becomes unavailable while the fax is being
|
|
received, the remainder unprinted pages of the fax will
|
|
be uploaded. If host then becomes unavailable, this
|
|
object will transition to ePrintOnly. Remainder pages
|
|
of the fax being uploaded will be stored in device
|
|
memory, to be printed when printer becomes available.
|
|
If device memory becomes full, no subsequent calls will
|
|
be answered. If power is cycled on the device, the user
|
|
must be informed of any lost faxes.
|
|
eForwardElsePrint - Received faxes are to be forwarded
|
|
to another fax station. If remote number does not
|
|
answer, fax is printed. If remote number is busy on
|
|
multiple redial attempts, the fax is printed. If device
|
|
memory becomes full before fax reception is complete,
|
|
the fax is printed. If printer becomes unavailable, the
|
|
fax is stored in device memory and then printed when
|
|
printer becomes available again. "
|
|
::= { settings-fax-proc-sub 19 }
|
|
|
|
|
|
fax-error-correction-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the device is configured to send
|
|
and receive faxes in error correction mode (ECM).
|
|
This object controls both receiving and transmitting
|
|
in ECM. A value of eDisabled means ECM is off and the
|
|
device will not advertise the ability to do ECM during
|
|
negotiation with other fax machines. A value of eEnabled
|
|
means ECM is on and the device will advertise its ability
|
|
to do ECM.
|
|
|
|
Changing this setting may or may not take affect on the
|
|
immediate page or ensuing pages of the document
|
|
currently being sent."
|
|
::= { settings-fax-proc-sub 21 }
|
|
|
|
|
|
fax-report-transmission OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNone(1),
|
|
ePrintReport(2),
|
|
ePrintReportOnSend(3),
|
|
ePrintReportOnError(4),
|
|
ePrintReportOnSendError(5),
|
|
ePrintReportOnReceiveError(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides a host application with the ability to
|
|
print a fax transmission report. The supported
|
|
enumerations are:
|
|
eNone - no transmission report printed
|
|
ePrintReport - transmission report always printed
|
|
ePrintReportOnSend - transmission report printed on
|
|
send only
|
|
ePrintReportOnError - transmission report printed on
|
|
error only
|
|
ePrintReportOnSendError - transmission report printed
|
|
on send error only
|
|
ePrintReportOnReceiveError - transmission report
|
|
printed on receive error only."
|
|
::= { settings-fax-proc-sub 22 }
|
|
|
|
|
|
fax-report-activity-log OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNever(1),
|
|
eThreshold(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies when a report of fax transactions is to be
|
|
printed.
|
|
|
|
eNever - to never print a transaction report.
|
|
eThreshold - to automatically print a transaction
|
|
report every N transactions.
|
|
|
|
The POS for each product shall specify the value of N.
|
|
|
|
FAX-REPORT-TRANSMISSION also prints a transaction report,
|
|
but for only a given fax, not a log of fax activities.
|
|
May not be settable if the fax machine is not idle.
|
|
|
|
The log is cleared after each printing caused by this
|
|
object."
|
|
::= { settings-fax-proc-sub 23 }
|
|
|
|
|
|
fax-dial-tone-detection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether the fax machine waits for a dial tone
|
|
before dialing a fax number. eEnabled - causes the fax
|
|
machine to wait until a dial tone is recognized before
|
|
attempting to dial a fax number. eDisabled - causes the
|
|
fax machine to dial without waiting to recognize a dial
|
|
tone."
|
|
::= { settings-fax-proc-sub 24 }
|
|
|
|
|
|
fax-alarm-volume OBJECT-TYPE
|
|
SYNTAX INTEGER(0..3)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Range is 0..100, where 0 = quietest possible, and
|
|
100 = loudest possible. A device shall divide this value
|
|
into ranges corresponding to the possible volumes and
|
|
document these settings and their meanings in the product
|
|
POS.
|
|
Additional information:
|
|
For HP Laserjet 3200 the range is 0..3, where 0=off (silent),
|
|
1=soft, 2=medium, and 3=loud."
|
|
::= { settings-fax-proc-sub 25 }
|
|
|
|
|
|
fax-beep-volume OBJECT-TYPE
|
|
SYNTAX INTEGER(0..3)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Range is 0..100, where 0 = quietest possible, and
|
|
100 = loudest possible. A device shall divide this value
|
|
into ranges corresponding to the possible volumes and
|
|
document these settings and their meanings in the product
|
|
POS.
|
|
Additional information:
|
|
For HP Laserjet 3200 the range is 0..3, where 0=off (silent),
|
|
1=soft, 2=medium, and 3=loud."
|
|
::= { settings-fax-proc-sub 26 }
|
|
|
|
|
|
fax-ring-volume OBJECT-TYPE
|
|
SYNTAX INTEGER(0..3)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Range is 0..100, where 0 = quietest possible, and
|
|
100 = loudest possible. A device shall divide this value
|
|
into ranges corresponding to the possible volumes and
|
|
document these settings and their meanings in the product
|
|
POS.
|
|
Additional information:
|
|
For HP Laserjet 3200 the range is 0..3, where 0=off (silent),
|
|
1=soft, 2=medium, and 3=loud."
|
|
::= { settings-fax-proc-sub 27 }
|
|
|
|
|
|
fax-master-host OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the hostname of the master host to which
|
|
the device is connected."
|
|
::= { settings-fax-proc-sub 28 }
|
|
|
|
|
|
fax-thumbnail-enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether or not a thumbnail reprint of the
|
|
first page of a fax shall be included on the
|
|
fax call report. When set to eEnabled a thumbnail shall
|
|
be included on the report. When set to eDisabled there
|
|
shall be not be a thumbnail on the fax call report.
|
|
Additional information:
|
|
Controls whether or not a thumbnail reprint of the
|
|
first page of a fax shall be included on the
|
|
fax call report. When set to eEnabled a thumbnail shall
|
|
be included on the report. When set to eDisabled there
|
|
shall be not be a thumbnail on the fax call report."
|
|
::= { settings-fax-proc-sub 29 }
|
|
|
|
|
|
fax-phone-pickup-enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is included to handle the situation where a
|
|
fax machine and a telephone share the same phone line.
|
|
|
|
If a call picked up at the phone turns out to be a fax
|
|
call, the user may initiate a fax receive via the fax
|
|
machine front panel (with, say, a button press). When
|
|
this object is set to eEnabled and a fax call is answered
|
|
at the phone, the user has the option of initiating the
|
|
fax receive in the usual way at the fax front panel or by
|
|
entering a (product-specific) key sequence on the telephone
|
|
keypad (e.g. '***'). The device POS must indicate what
|
|
the key sequence is for a particular product.
|
|
|
|
When this object is set to eDisabled and a fax call is
|
|
answered at the phone, the user may only initiate the fax
|
|
receive by taking the product-specific action (such as a
|
|
button press) at the fax machine front panel.
|
|
|
|
It is necessary to be able to turn this feature off (i.e.
|
|
set it to eDisabled) because the key sequence of a
|
|
particular fax device may interfere with other devices
|
|
connected to the phone line (e.g. an answering machine).
|
|
Additional information:
|
|
On HP Laserjet 3200, the key sequence to initiate a fax from the
|
|
phone keypad is '***'."
|
|
::= { settings-fax-proc-sub 30 }
|
|
|
|
|
|
fax-adf-scan-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object tracks the page count for the pages scanned for
|
|
faxing from the ADF. In order to write this object
|
|
SERVICE-PASSWORD must be set correctly.
|
|
Additional information:
|
|
This object tracks the page count for the pages scanned for faxing
|
|
from the ADF. In order to write this object SERVICE-PASSWORD must be
|
|
set correctly."
|
|
::= { settings-fax-proc-sub 31 }
|
|
|
|
|
|
fax-print-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object tracks the page count for the pages sent to the
|
|
print engine for fax jobs. In order to write this object
|
|
SERVICE-PASSWORD must be set correctly.
|
|
Additional information:
|
|
This object tracks the page count for the pages sent to the print
|
|
engine for fax jobs. In order to write this object SERVICE-PASSWORD
|
|
must be set correctly."
|
|
::= { settings-fax-proc-sub 32 }
|
|
|
|
|
|
fax-download-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object tracks the page count for the pages downloaded to
|
|
the peripheral for fax jobs. In order to write this object
|
|
SERVICE-PASSWORD must be set correctly.
|
|
Additional information:
|
|
This object tracks the page count for the pages downloaded to the
|
|
peripheral for fax jobs. In order to write this object SERVICE-PASSWORD
|
|
must be set correctly."
|
|
::= { settings-fax-proc-sub 33 }
|
|
|
|
|
|
fax-upload-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object tracks the page count for the pages uploaded from
|
|
the peripheral for fax jobs. In order to write this object
|
|
SERVICE-PASSWORD must be set correctly.
|
|
Additional information:
|
|
This object tracks the page count for the pages uploaded from the
|
|
peripheral for fax jobs. In order to write this object SERVICE-PASSWORD
|
|
must be set correctly."
|
|
::= { settings-fax-proc-sub 34 }
|
|
|
|
|
|
fax-flatbed-scan-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object tracks the page count for the pages scanned for
|
|
faxing from the flatbed. In order to write this object the
|
|
SERVICE-PASSWORD must be set.
|
|
Additional information:
|
|
This object tracks the page count for the pages scanned
|
|
for faxing from the flatbed. In order to write this
|
|
object the SERVICE-PASSWORD must be set."
|
|
::= { settings-fax-proc-sub 36 }
|
|
|
|
|
|
default-fax-glass-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eISOandJISA4(26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the default fax glass size.
|
|
Additional information:
|
|
Indicates the default fax glass size."
|
|
::= { settings-fax-proc-sub 37 }
|
|
|
|
|
|
fax-cold-reset-fax-glass-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eISOandJISA4(26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Returns or sets the fax glass size that is used as the
|
|
DEFAULT-FAX-GLASS-SIZE when a cold reset occurs.
|
|
Additional information:
|
|
Returns or sets the fax glass size that is used as the
|
|
DEFAULT-FAX-GLASS-SIZE when a cold reset occurs."
|
|
::= { settings-fax-proc-sub 38 }
|
|
|
|
|
|
fax-upload OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFaxUploadIdle(1),
|
|
eFaxUploadStart(2),
|
|
eFaxUploadActive(3),
|
|
eFaxUploadAborted(4),
|
|
eFaxUploadDone(5),
|
|
eFaxUploadNeeded(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Note: The enumeration values for this object where
|
|
changed in a non-backwards compatible manner in version
|
|
4.7. Handshake mechanism between host and device to
|
|
notify and coordinate the transfer of fax image data
|
|
received by the device fax modem. This object serves
|
|
both as an indicator of fax upload activity as well as a
|
|
trigger for the host to alter fax upload progress.
|
|
Handshake mechanism between host and device to initiate
|
|
scan operation and coordinate the transfer of scanned
|
|
image data to the host. This object serves both as an
|
|
indicator of scan upload activity as well as a trigger
|
|
for the host to alter scan upload progress.
|
|
eFaxUploadIdle - indicates no fax upload activity is
|
|
is occurring. Device powers up in this state but will
|
|
otherwise never transition to this state of its own
|
|
accord. Host setting to eFaxUploadIdle while object is
|
|
in eFaxUploadActive will cause download activity to be
|
|
prematurely terminated. Host setting to this state
|
|
resets the handshake mechanism to permit another fax
|
|
upload activity to be initiated.
|
|
eFaxUploadStart - indicates the host requests to
|
|
commence an upload session for a received fax. This
|
|
state is host settable only from eFaxUploadIdle. Device
|
|
will never transition to this state of its own accord.
|
|
eFaxUploadActive - indicates a fax upload is
|
|
occurring. This state is not host settable. Device
|
|
will transition to this state from eFaxUploadStart as a
|
|
positive response for host to commence upload of fax
|
|
data. The object FAXJOB-UPLOAD-ID now contains the job
|
|
ID.
|
|
eFaxUploadAborted - indicates the fax upload activity
|
|
has been prematurely terminated by the device due to
|
|
some error. Object FAX-UPLOAD-ERROR contains the error
|
|
reason for the premature session termination. This
|
|
state is device settable from eFaxUploadStart,
|
|
eFaxUploadActive or eFaxUploadNeeded. This state is not
|
|
host settable.
|
|
eFaxUploadDone - indicates the fax upload activity has
|
|
reached a successful termination in that the device has
|
|
transmitted all the upload data to the host. This state
|
|
is only settable by the device from eFaxUploadActive.
|
|
This state is not host settable. Host should transition
|
|
from this state to eFaxUploadIdle in order to reset the
|
|
handshake mechanism for subsequent upload session.
|
|
eFaxUploadNeeded - indicates device has received fax
|
|
modem data available for host upload. This state is not
|
|
host settable. This state is device settable from
|
|
eFaxUploadIdle. Host should respond by setting to
|
|
eFaxUploadStart to initiate upload session. Should host
|
|
fail to respond by the time fax reception is complete or
|
|
device has exhausted local memory storage, device shall
|
|
transition object from eFaxUploadNeeded to
|
|
eFaxUploadAborted. The POS should state the recourse
|
|
behavior associated with the received fax."
|
|
::= { status-fax-proc-sub 1 }
|
|
|
|
|
|
fax-min-rings-pickup OBJECT-TYPE
|
|
SYNTAX INTEGER(1..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum legal rings before pickup.
|
|
Additional information:
|
|
GECKO NOTE: Do all countries on the HP Laserjet 3200 list allow a
|
|
minimum of 1? If not, object syntax must be amended."
|
|
::= { status-fax-proc-sub 2 }
|
|
|
|
|
|
fax-max-rings-pickup OBJECT-TYPE
|
|
SYNTAX INTEGER(1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum legal rings before pickup."
|
|
::= { status-fax-proc-sub 3 }
|
|
|
|
|
|
fax-max-redials OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of allowed redials."
|
|
::= { status-fax-proc-sub 4 }
|
|
|
|
|
|
fax-additional-wait OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of additional seconds to wait before beginning a
|
|
FAX-DOWNLOAD."
|
|
::= { status-fax-proc-sub 5 }
|
|
|
|
|
|
fax-download-error OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error status of the fax download session.
|
|
Additional information:
|
|
GECKO NOTE: What error conditions will be reported by
|
|
this object? Provide a map for the meaning of each
|
|
valid value here."
|
|
::= { status-fax-proc-sub 6 }
|
|
|
|
|
|
fax-upload-error OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error status of the fax upload session.
|
|
Additional information:
|
|
GECKO NOTE: What error conditions will be reported by
|
|
this object? Provide a map for the meaning of each
|
|
valid value here. Does this functionality stay? If not,
|
|
this object is superfluous."
|
|
::= { status-fax-proc-sub 7 }
|
|
|
|
|
|
fax-firmware-revision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the fax firmware ROM revision
|
|
code. The format is device specific and shall be
|
|
specified in the device POS.
|
|
Additional information:
|
|
This object identifies the fax firmware ROM revision
|
|
code. For HP Laserjet 3200, the format for this object is a date
|
|
in the form YYYYMMDD."
|
|
::= { status-fax-proc-sub 8 }
|
|
|
|
|
|
fax-forwarding-phone-num OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Phone number digits of the remote fax station where
|
|
arrived faxes are to be forwarded."
|
|
::= { fax-forwarding 3 }
|
|
|
|
|
|
fax-resolution OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"struct {
|
|
unsigned_32bit x_res; /* 1st four bytes; big endian */
|
|
unsigned_32bit y_res; /* 2nd four bytes; big endian */
|
|
}
|
|
Sets the send fax resolution. The x and y resolutions
|
|
in this object are in fixed-point with 16 bits of
|
|
fraction, and 16 bits of integer, and are in dots per
|
|
inch. X is horizontal; Y is vertical.
|
|
Examples of computing x_res and y_res:
|
|
300 dots/inch:round(300 * 65536) = 19660800
|
|
16 dots/mm: round(16 * 25.4 * 65536) = 26633830.
|
|
If the device does not support the given combination,
|
|
then it'll select the nearest supported values in a
|
|
device-dependent manner (documented in the POS).
|
|
Additional information:
|
|
HP Laserjet 3200 supports 4 fax resolutions. As far as the
|
|
end-user is concerned these resolutions are: standard,
|
|
fine, superfine, and photo. Photo is not really a
|
|
resolution--see more below. Standard is the default.
|
|
Resolutions map as follows (values are given in dots per
|
|
inch (dpi) horizontal X vertical (x X y)): standard(203
|
|
X 98), fine(203 X 196), superfine(300 X 300), and
|
|
photo(300 X 300).
|
|
|
|
Supported resolutions in hex notation (dpi, x X y) are:
|
|
standard(00cb0000 X 00620000), fine(00cb0000 X 00c4000),
|
|
superfine(012C0000 X 012C0000), and photo(012C0000 X
|
|
012C0000).
|
|
|
|
The device ignores attempts to set invalid resolutions.
|
|
|
|
Photo is not a resolution, but photo setting depends on
|
|
whether half-toning is on or off. In the case of HP Laserjet 3200
|
|
photo setting doesn't actually change the bits going out
|
|
the modem -- still one bit per pixel so photo and
|
|
superfine are the same.
|
|
|
|
NOTE: The last 16 bits of the horizontal and vertical
|
|
settings are ignored. Only the first 16 bits of the
|
|
horizontal and vertical resolution setting are used."
|
|
::= { settings-fax-send 1 }
|
|
|
|
|
|
fax-contrast OBJECT-TYPE
|
|
SYNTAX INTEGER(-127..127)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Behaves as SCL's 'Set Scanner Contrast Level' command
|
|
which is used for setting the sending fax contrast
|
|
level. Range is 0..100.
|
|
Additional information:
|
|
Behaves as COPIER-CONTRAST and SCANNER-CONTRAST.
|
|
Contrast values can range from -127 to +127, for a total
|
|
of 255 contrast values. Within that range, HP Laserjet 3200
|
|
supports 11 values. They are: -125, -100, -75, -50,
|
|
-25, 0, 25, 50, 75, 100, 125. The default contrast level is 0
|
|
(normal). A positive value results in a larger
|
|
difference, and a negative value results in a smaller
|
|
difference.
|
|
|
|
HP Laserjet 3200 snaps unsupported values toward zero as follows:
|
|
<=-125 snaps to -125
|
|
>-125 and <=-100 snaps to -100
|
|
>-100 and <=-75 snaps to -75
|
|
>-75 and <=-50 snaps to -50
|
|
>-50 and <=-25 snaps to -25
|
|
>-25 and <25 snaps to 0
|
|
>=25 and <50 snaps to 25
|
|
>=50 and <75 snaps to 50
|
|
>=75 and <100 snaps to 75
|
|
>=100 and <125 snaps to 100
|
|
>=125 snaps to 125"
|
|
::= { settings-fax-send 2 }
|
|
|
|
|
|
fax-pixel-data-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eBiLevelThesholded(1),
|
|
eBiLevelHalfToned(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the scanning method used when sending a fax.
|
|
eBiLevelThesholded - One bit per pixel, using
|
|
simple thresholding of greyscale
|
|
scan data.
|
|
eBiLevelHalfToned - One bit per pixel, using some kind
|
|
of half-toning technique (such as
|
|
dithering or error-diffusion) to
|
|
approximate greyscale scan data."
|
|
::= { settings-fax-send 3 }
|
|
|
|
|
|
not-ready-fax-send OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the sending fax sub-system in the device is
|
|
not ready. If there are no items in the collection
|
|
(i.e. no bits are set), then the sending fax sub-system
|
|
is ready. If there is an item present, then the item
|
|
indicates what is causing the sending fax sub-system to
|
|
be not ready."
|
|
::= { status-fax-send 1 }
|
|
|
|
|
|
fax-allow-redials OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When eTrue, the FAX machine can redial a phone number if
|
|
the prior call failed for some reason. When eFalse,
|
|
such redialing will not occur."
|
|
::= { transmit-fax 3 }
|
|
|
|
error1-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 1
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
This item contains the engine
|
|
page count when the error occurred.
|
|
|
|
If there is currently no error entry for this object, a '0' will be returned.
|
|
Note that '0' may also be returned when there is a valid error, but a current
|
|
page count was unavailable. If ERROR1-CODE object also returns '0', then
|
|
an error has not yet been logged for this object.
|
|
|
|
See ERROR1-CODE for an explanation of the order used for storing errors."
|
|
::= { error1 1 }
|
|
|
|
|
|
error1-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
Returns a device specific error code.
|
|
If the error code returned is '0', then the printer has not yet logged an
|
|
error for this object.
|
|
When the maximum number of errors is reached (30 on LaserJet 4050 Series printers), and
|
|
a new error occurs, the error in ERROR1-CODE will be replaced by the
|
|
one in ERROR2-CODE, and so on until the last error object will be given
|
|
the value of the new error.
|
|
|
|
The error number is returned in the upper 16 bits.
|
|
If it is 68, 69, 79, or 80, then the sub code is returned in the lower
|
|
16 bits (eg. 68 001C, where the subcode is already a hexadecimal value).
|
|
If the error number is any other number, then the 1st sub code (XX)
|
|
will be in bits 15-8 and the 2nd sub code (YY) will be in bits 7-0 (eg.
|
|
55.04.02) where XX=04 and YY=02).
|
|
|
|
Example: If the error is 68 001A, then the value returned will be 4456474.
|
|
To break it down: 4456474 = 0x0044001A
|
|
The upper 16 bits: 0x0044 = 68
|
|
The lower 16 bits: 0x001A = 001A
|
|
Which is the error: 68 001A
|
|
|
|
Example: If the error is 55.04.241, then the error code will be 3605745.
|
|
To break it down: 3605745 = 0x003704F1
|
|
The upper 16 bits: 0x0037 = 55
|
|
The upper byte of the lower 16 bits: 0x04 = 04
|
|
The lower byte of the lower 16 bits: 0xF1 = 241
|
|
Which is the error: 55.04.241"
|
|
::= { error1 2 }
|
|
|
|
|
|
error2-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 2
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error2 1 }
|
|
|
|
|
|
error2-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error2 2 }
|
|
|
|
|
|
error3-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 3
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error3 1 }
|
|
|
|
|
|
error3-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error3 2 }
|
|
|
|
|
|
error4-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 4
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error4 1 }
|
|
|
|
|
|
error4-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error4 2 }
|
|
|
|
|
|
error5-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 5
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error5 1 }
|
|
|
|
|
|
error5-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error5 2 }
|
|
|
|
|
|
error6-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 6
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error6 1 }
|
|
|
|
|
|
error6-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error6 2 }
|
|
|
|
|
|
error7-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 7
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error7 1 }
|
|
|
|
|
|
error7-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error7 2 }
|
|
|
|
|
|
error8-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 8
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error8 1 }
|
|
|
|
|
|
error8-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error8 2 }
|
|
|
|
|
|
error9-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error 9
|
|
occurred. Example time stamps include the actual time
|
|
the error occurred (in seconds since Jan. 1, 1970), and
|
|
the total engine page count. The device POS documents
|
|
the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error9 1 }
|
|
|
|
|
|
error9-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error9 2 }
|
|
|
|
|
|
error10-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
10 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error10 1 }
|
|
|
|
|
|
error10-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error10 2 }
|
|
|
|
|
|
error11-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
11 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error11 1 }
|
|
|
|
|
|
error11-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error11 2 }
|
|
|
|
|
|
error12-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
12 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error12 1 }
|
|
|
|
|
|
error12-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error12 2 }
|
|
|
|
|
|
error13-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
13 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error13 1 }
|
|
|
|
|
|
error13-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error13 2 }
|
|
|
|
|
|
error14-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
14 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error14 1 }
|
|
|
|
|
|
error14-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error14 2 }
|
|
|
|
|
|
error15-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
15 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error15 1 }
|
|
|
|
|
|
error15-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error15 2 }
|
|
|
|
|
|
error16-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
16 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error16 1 }
|
|
|
|
|
|
error16-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error16 2 }
|
|
|
|
|
|
error17-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
17 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error17 1 }
|
|
|
|
|
|
error17-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error17 2 }
|
|
|
|
|
|
error18-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
18 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error18 1 }
|
|
|
|
|
|
error18-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error18 2 }
|
|
|
|
|
|
error19-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
19 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error19 1 }
|
|
|
|
|
|
error19-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error19 2 }
|
|
|
|
|
|
error20-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
20 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error20 1 }
|
|
|
|
|
|
error20-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error20 2 }
|
|
|
|
|
|
error21-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
21 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error21 1 }
|
|
|
|
|
|
error21-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error21 2 }
|
|
|
|
|
|
error22-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
22 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error22 1 }
|
|
|
|
|
|
error22-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error22 2 }
|
|
|
|
|
|
error23-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
23 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error23 1 }
|
|
|
|
|
|
error23-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error23 2 }
|
|
|
|
|
|
error24-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
24 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error24 1 }
|
|
|
|
|
|
error24-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error24 2 }
|
|
|
|
|
|
error25-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
25 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error25 1 }
|
|
|
|
|
|
error25-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error25 2 }
|
|
|
|
|
|
error26-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
26 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error26 1 }
|
|
|
|
|
|
error26-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error26 2 }
|
|
|
|
|
|
error27-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
27 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error27 1 }
|
|
|
|
|
|
error27-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error27 2 }
|
|
|
|
|
|
error28-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
28 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error28 1 }
|
|
|
|
|
|
error28-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error28 2 }
|
|
|
|
|
|
error29-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
29 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error29 1 }
|
|
|
|
|
|
error29-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error29 2 }
|
|
|
|
|
|
error30-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
30 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error30 1 }
|
|
|
|
|
|
error30-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error30 2 }
|
|
|
|
error31-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains some sort of time stamp indicating when error
|
|
31 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error31 1 }
|
|
|
|
|
|
error31-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error31 2 }
|
|
|
|
error32-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
32 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error32 1 }
|
|
|
|
|
|
error32-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error32 2 }
|
|
|
|
|
|
error33-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
33 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error33 1 }
|
|
|
|
|
|
error33-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error33 2 }
|
|
|
|
|
|
error34-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
34 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error34 1 }
|
|
|
|
|
|
error34-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error34 2 }
|
|
|
|
|
|
error35-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
35 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error35 1 }
|
|
|
|
|
|
error35-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error35 2 }
|
|
|
|
|
|
error36-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
36 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error36 1 }
|
|
|
|
|
|
error36-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error36 2 }
|
|
|
|
|
|
error37-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
37 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error37 1 }
|
|
|
|
|
|
error37-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error37 2 }
|
|
|
|
|
|
error38-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
38 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error38 1 }
|
|
|
|
|
|
error38-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error38 2 }
|
|
|
|
|
|
error39-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
39 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error39 1 }
|
|
|
|
|
|
error39-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error39 2 }
|
|
|
|
|
|
error40-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
40 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error40 1 }
|
|
|
|
|
|
error40-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error40 2 }
|
|
|
|
|
|
error41-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
41 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error41 1 }
|
|
|
|
|
|
error41-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error41 2 }
|
|
|
|
|
|
error42-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
42 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error42 1 }
|
|
|
|
|
|
error42-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error42 2 }
|
|
|
|
|
|
error43-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
43 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error43 1 }
|
|
|
|
|
|
error43-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error43 2 }
|
|
|
|
|
|
error44-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
44 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error44 1 }
|
|
|
|
|
|
error44-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error44 2 }
|
|
|
|
|
|
error45-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
45 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error45 1 }
|
|
|
|
|
|
error45-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error45 2 }
|
|
|
|
|
|
error46-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
46 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error46 1 }
|
|
|
|
|
|
error46-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error46 2 }
|
|
|
|
|
|
error47-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
47 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error47 1 }
|
|
|
|
|
|
error47-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error47 2 }
|
|
|
|
|
|
error48-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
48 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error48 1 }
|
|
|
|
|
|
error48-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error48 2 }
|
|
|
|
|
|
error49-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
49 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error49 1 }
|
|
|
|
|
|
error49-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error49 2 }
|
|
|
|
|
|
error50-time-stamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a time stamp indicating when error
|
|
50 occurred. Example time stamps include the actual
|
|
time the error occurred (in seconds since Jan. 1, 1970),
|
|
and the total engine page count. The device POS
|
|
documents the meaning of the time stamp.
|
|
Additional information:
|
|
See ERROR1-TIME-STAMP."
|
|
::= { error50 1 }
|
|
|
|
|
|
error50-code OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a device specific error code. Each device POS
|
|
should list what errors are logged to the error log and
|
|
the meaning of each supported error code value.
|
|
Additional information:
|
|
See ERROR1-CODE."
|
|
::= { error50 2 }
|
|
|
|
io-timeout OBJECT-TYPE
|
|
SYNTAX INTEGER(5..300)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in seconds, to wait for more print
|
|
job data to be received before an I/O timeout occurs.
|
|
The I/O channel being timed is the I/O channel that
|
|
received the data associated with the current print job.
|
|
If an I/O timeout occurs, the PDL processing sub-system
|
|
assumes all the data associated with the current print
|
|
job has been received, and processes the end of job in
|
|
an PDL specific manner. The POS specifies the supported
|
|
values.
|
|
Additional information:
|
|
If an I/O timeout occurs,the PDL processing
|
|
sub-system will consider it an end of job condition only
|
|
if there is data from another I/O subsystem waiting to be
|
|
processed.
|
|
The supported values are 5 to 300 seconds.
|
|
Setting to a value outside the supported range returns
|
|
<noError> status and the
|
|
value will be snapped to the nearest supported
|
|
value."
|
|
::= { settings-io 1 }
|
|
|
|
|
|
io-switch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eYes(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the device will switch between I/O channels
|
|
when a job boundary is encountered and print job data is
|
|
available on another I/O channel."
|
|
::= { settings-io 2 }
|
|
|
|
|
|
io-buffering OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2),
|
|
eAuto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or controls the manner in which the device
|
|
performs I/O data buffering. I/O data buffering allows
|
|
additional print job data to be buffered by the I/O sub-
|
|
system in an effort to allow the computer sending the
|
|
data to perform other tasks and to keep the PDL
|
|
processing sub-system busy. eOff, I/O buffering is
|
|
disabled. When eOn, I/O buffering is enabled and the
|
|
IO-BUFFER-SIZE object controls the amount of memory set
|
|
aside for I/O buffer. When eAuto, I/O buffering is
|
|
enabled and the I/O buffer size is determined
|
|
automatically by the device and the IO-BUFFER-SIZE
|
|
object is not used.
|
|
Additional information:
|
|
In a PCL-only printer, all values may be set at any time.
|
|
|
|
When there is less than 4M of memory installed, setting this object to eOn
|
|
or eAuto will cause <badValue> to be returned.
|
|
At exactly 4M of memory, eOn is not a valid setting. At more than 4M
|
|
of memory any setting is valid, subject to the conditions listed in the
|
|
interactions below."
|
|
::= { settings-io 5 }
|
|
|
|
|
|
io-buffer-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or configures the amount of memory, in bytes,
|
|
dedicated to I/O print job data buffering. Attempting
|
|
to set to an unsupported value causes the device to use
|
|
the closest supported value. Each device POS should
|
|
document the list of supported values.
|
|
Additional information:
|
|
In LaserJet 4050 Series the minimum supported value is 10K bytes
|
|
(10240).
|
|
The maximum supported value is dependent on total memory installed
|
|
and the amount of memory currently being used by other memory
|
|
consumers. Use the MAXIMUM-IO-BUFFERING-MEMORY object to determine
|
|
this value.
|
|
|
|
The following rules determine legal values for this object:
|
|
1) Sizes less than 10K bytes will snap to 10K bytes.
|
|
2) Sizes between 10K and 100K bytes will be rounded to the nearest 10K.
|
|
3) Sizes between 100K bytes and the maximum value allowed will round to
|
|
the nearest 100K bytes.
|
|
|
|
If the value had to be snapped or rounded, <noError>
|
|
will be returned along with the actual value that was written.
|
|
|
|
Attempting to set this object when IO-BUFFERING is eOff will cause a status
|
|
of <genErr> to be returned. When IO-BUFFERING is
|
|
eOff, reading this object will return a value of zero."
|
|
::= { settings-io 6 }
|
|
|
|
|
|
maximum-io-buffering-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object's name is misleading. Returns the maximum
|
|
amount of additional memory, in bytes, that can be
|
|
dedicated to buffering print job data."
|
|
::= { settings-io 7 }
|
|
|
|
not-ready-source-io OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the I/O sub-system in the device is not
|
|
ready. If there are no items in the collection (i.e. no
|
|
bits are set), then the I/O sub-system is ready. If
|
|
there is an item present, then the item indicates what
|
|
is causing the I/O sub-system to be not ready. If the
|
|
I/O sub-system is not ready due to a soft error, the
|
|
soft error is considered to be an auto-continuable
|
|
error, thus it can be acknowledged by setting the
|
|
CONTINUE object to eTrue."
|
|
::= { status-io 1 }
|
|
|
|
|
|
status-source-io OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the I/O sub-system in a warning condition."
|
|
::= { status-io 2 }
|
|
|
|
parallel-speed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eSlow(1),
|
|
eFast(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the maximum parallel I/O port speed.
|
|
An eSlow setting causes a 10 us busy pulse per received
|
|
byte of data. An eFast setting causes a 1.5 us busy
|
|
pulse per received byte of data. In rare cases, setting
|
|
this value to eFast can cause the parallel port to no
|
|
longer transfer data reliably."
|
|
::= { parallel 4 }
|
|
|
|
|
|
parallel-bidirectionality OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUnidirectional(1),
|
|
eBidirectional(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes whether the parallel I/O port
|
|
supports bidirectional communication."
|
|
::= { parallel 5 }
|
|
|
|
|
|
port1-parallel-speed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eSlow(1),
|
|
eFast(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the maximum parallel I/O port speed,
|
|
for port 1. This object is only supported if this port
|
|
is a parallel port. An eSlow setting causes a 10 us
|
|
busy pulse per received byte of data. An eFast setting
|
|
causes a 1.5 us busy pulse per received byte of data.
|
|
In rare cases, setting this value to eFast can cause the
|
|
parallel port to no longer transfer data reliably."
|
|
::= { port1 4 }
|
|
|
|
|
|
port1-parallel-bidirectionality OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUnidirectional(1),
|
|
eBidirectional(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes whether the parallel I/O port
|
|
supports bidirectional communication for port 1. This
|
|
object is only supported if this port is a parallel
|
|
port.
|
|
Additional information:
|
|
A get on this object returns the current mode
|
|
for the parallel port. Setting this object specifies whether or not
|
|
bidirectional communications will be allowed."
|
|
::= { port1 5 }
|
|
|
|
default-orientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePortrait(1),
|
|
eLandscape(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the default orientation. The list of
|
|
supported values should be documented in the device
|
|
POS."
|
|
::= { settings-pdl 2 }
|
|
|
|
|
|
default-copies OBJECT-TYPE
|
|
SYNTAX INTEGER(1..999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes default copies. Default copies is
|
|
the default values used by the PDL to control the number
|
|
of copies of each page in the print job that are
|
|
printed. The print job can override this value. The
|
|
list of supported values should be documented in the
|
|
device POS.
|
|
Additional information:
|
|
The supported values are 1 through 999.
|
|
Setting to an unsupported value causes the printer to substitute in a snap
|
|
value and to return <noError> status.
|
|
The snaps are as follows:
|
|
<1 snaps to 1
|
|
>999 snaps to 999"
|
|
::= { settings-pdl 4 }
|
|
|
|
|
|
form-feed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInitiateAction(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instructs the PDL processing sub-system to finishing
|
|
processing the current page of the current job. Form
|
|
feed is also known as close page or eject page. If the
|
|
PDL processing sub-system is in a FORM-FEED-NEEDED
|
|
state, this causes the device to flush or finish
|
|
processing the current page of the current job. If the
|
|
device is not in the FORM-FEED-NEEDED state, an
|
|
<genErr> will occur."
|
|
::= { settings-pdl 5 }
|
|
|
|
|
|
resource-saving OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2),
|
|
eAuto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes PDL resource saving. Resource saving
|
|
stores a PDL's permanent soft resources, like fonts,
|
|
even when another PDL is active. Resource saving is
|
|
also called environment saving. When eOff, resource
|
|
saving is disabled. When ON, resource saving is enabled
|
|
and memory is set aside for each PDL based on that PDL's
|
|
resource saving memory size object, to store that PDL's
|
|
permanent soft resources. When eAuto, resource saving
|
|
is enabled and memory space for each installed PDL is
|
|
determined automatically. The device POS should
|
|
document what values are legal when only one PDL is
|
|
installed.
|
|
Additional information:
|
|
When PCL (including PCL/XL) is the only PDL
|
|
installed in LaserJet 4050 Series, eOn is not a legal value. Attempting to set this object to
|
|
eOn with a PCL-only printer will result in a status of
|
|
<badValue> being returned.
|
|
|
|
When Postscript is installed and less than 8 Megabytes of RAM are present,
|
|
resource saving is not available. The only valid value for this object
|
|
is eOff. Attempting to set this object to eOn or eAuto will cause
|
|
<badValue> to be returned.
|
|
|
|
When Postscript and 8 Megabytes or more of RAM are installed, all values
|
|
are valid, provided I/O Buffering, Mopying, or Ram Disk have not consumed
|
|
the needed memory.
|
|
|
|
This object is only supported if Postscript is resident in the printer."
|
|
::= { settings-pdl 6 }
|
|
|
|
|
|
maximum-resource-saving-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object's name is misleading. This object returns
|
|
the maximum amount of additional memory, in bytes, that
|
|
can be dedicated to holding PDL permanent soft
|
|
resources.
|
|
Additional information:
|
|
NOTE: The values listed below have not been verified
|
|
on LaserJet 4050 Series. The following numbers assume that IO-BUFFERING=eOff;
|
|
if IO-BUFFERING<>eOff, the following numbers will be reduced by the value of
|
|
IO-BUFFER-SIZE.
|
|
|
|
Memory for resource saving is allocated in increments of 102400 bytes.
|
|
Therefore, for each 1M (1048576 bytes) of memory added to the printer, 102400
|
|
bytes are made available to resource saving (and I/O buffering) and 24576
|
|
bytes are retained until an additional 102400 byte block can be made
|
|
available. The value reported by this object is always rounded down to the
|
|
nearest multiple of 102400.
|
|
|
|
For a PCL-only printer, the value of this object is zero (all resource saving
|
|
memory is dedicated to PCL).
|
|
|
|
If PostScript is installed without a duplex unit, the value of this object is
|
|
as follows:
|
|
Zero if <7M memory is installed.
|
|
1048576 if 7M memory is installed and RESOURCE-SAVING=eOff.
|
|
1048576 if 7M memory is installed and RESOURCE-SAVING=eOn (note that this
|
|
value will be reduced by the amount of memory allocated to
|
|
PCL-RESOURCE-SAVING-MEMORY-SIZE and POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE).
|
|
819200 if 7M memory is installed and RESOURCE-SAVING=eAuto.
|
|
When RESOURCE-SAVING=eAuto, 819200 bytes of each 1M over 7M memory installed
|
|
are allocated to PCL and PostScript (409600 each) with the remaining bytes
|
|
added to this object.
|
|
When RESOURCE-SAVING=eOn or eOff, all bytes over 13M memory installed are
|
|
added to this object.
|
|
|
|
If PostScript is installed with a duplex unit, the value of this object is as
|
|
follows:
|
|
Zero if <13M memory is installed.
|
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eOff.
|
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eOn (note that this
|
|
value will be reduced by the amount of memory allocated to
|
|
PCL-RESOURCE-SAVING-MEMORY-SIZE and POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE).
|
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eAuto.
|
|
When RESOURCE-SAVING=eAuto, 810200 bytes of each 1M over 13M memory installed
|
|
are allocated to PCL and PostScript (409600 each) with the remaining bytes
|
|
added to this object.
|
|
When RESOURCE-SAVING=eOn or eOff, all bytes over 13M memory installed are
|
|
added to this object.
|
|
|
|
The above listed values returned by this object will be reduced by the amount
|
|
of memory added to PCL-RESOURCE-SAVING-MEMORY-SIZE and
|
|
POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE when RESOURCE-SAVING=eOn."
|
|
::= { settings-pdl 7 }
|
|
|
|
|
|
default-vertical-black-resolution OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the value of the default vertical
|
|
black resolution. The units are dots per inch.
|
|
Additional information:
|
|
In LaserJet 4050 Series changing this OID also causes
|
|
DEFAULT- HORIZONTAL-BLACK RESOLUTION to change.
|
|
DEFAULT- HORIZONTAL-BLACK-RESOLUTION and
|
|
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
|
same. The supported values are 300 and 600
|
|
for LaserJet 8100 Series and LaserJet 8000 Series, and 300, 600, and 1200 for LaserJet 5000 Series
|
|
and LaserJet 4000 Series.
|
|
Setting to an unsupported value causes the printer
|
|
to substitute in a snap value and
|
|
to return <noError> status.
|
|
The snap values are as follow:
|
|
LaserJet 5000 Series and LaserJet 4000 Series:
|
|
n < 450 snaps to 300
|
|
450 >= n < 900 snaps to 600
|
|
n >= 900 snaps to 1200
|
|
LaserJet 8100 Series and LaserJet 8000 Series:
|
|
n < 450 snaps to 300
|
|
n >= 450 snaps to 600 "
|
|
::= { settings-pdl 8 }
|
|
|
|
|
|
default-horizontal-black-resolution OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the value of the default horizontal
|
|
black resolution. The units are dots per inch.
|
|
Additional information:
|
|
In LaserJet 4050 Series changing this object also causes
|
|
DEFAULT-VERTICAL-BLACK RESOLUTION to change.
|
|
DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
|
|
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
|
same. The supported values are 300 and 600
|
|
for LaserJet 8100 Series and LaserJet 8000 Series, and 300, 600, and 1200 for LaserJet 5000 Series
|
|
and LaserJet 4000 Series.
|
|
Setting to an unsupported value causes the printer
|
|
to substitute in a snap value and to
|
|
return <noError> status.
|
|
The snap values are as follow:
|
|
LaserJet 5000 Series and LaserJet 4000 Series:
|
|
n < 450 snaps to 300
|
|
450 >= n < 900 snaps to 600
|
|
n >= 900 snaps to 1200
|
|
LaserJet 8100 Series and LaserJet 8000 Series:
|
|
n < 450 snaps to 300
|
|
n >= 450 snaps to 600 "
|
|
::= { settings-pdl 9 }
|
|
|
|
|
|
default-page-protect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOn(2),
|
|
eAuto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the default page protection behavior.
|
|
If eOff, the device does not reserve memory for holding
|
|
the entire raster form of a processed page. If eOn,
|
|
then memory is reserved. If eAuto, the device
|
|
determines the amount of memory to reserve.
|
|
Additional information:
|
|
Setting to eOn causes MET to be more conservative, but
|
|
it will not allocate memory to hold an entire
|
|
rasterized page."
|
|
::= { settings-pdl 10 }
|
|
|
|
|
|
default-lines-per-page OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the default number of lines per page.
|
|
The POS indicates the supported values. An unsupported
|
|
value causes the printer to use the closest supported
|
|
value, causing the printer to return the
|
|
<noError>.
|
|
Additional information:
|
|
The supported values in LaserJet 4050 Series are 5 to 128.
|
|
Setting to an unsupported value causes the
|
|
the printer to substitute in a snap value and to return
|
|
<noError>
|
|
status.
|
|
The snap values are as follow:
|
|
<5 snaps to 5
|
|
>128 snaps to 128"
|
|
::= { settings-pdl 11 }
|
|
|
|
|
|
default-vmi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the default vertical motion index.
|
|
The unit of measure for VMI is centipoints per line.
|
|
The POS indicates the supported values. An unsupported
|
|
value causes the printer to use the closest supported
|
|
value, causing the printer to return
|
|
<noError>."
|
|
::= { settings-pdl 12 }
|
|
|
|
default-media-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eROC16K(17),
|
|
eJISExecutive(18),
|
|
eISOandJISA5(25),
|
|
eISOandJISA4(26),
|
|
eMonarch(80),
|
|
eCommercial10(81),
|
|
eInternationalDL(90),
|
|
eInternationalC5(91),
|
|
eInternationalB5(100),
|
|
eCustom(101)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the default media size. A write of an
|
|
unsupported value causes an <badValue>.
|
|
Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document."
|
|
::= { settings-pdl 13 }
|
|
|
|
|
|
cold-reset-media-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSLetter(2),
|
|
eISOandJISA4(26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the media size that is used as the
|
|
DEFAULT-MEDIA-SIZE when a cold reset occurs."
|
|
::= { settings-pdl 19 }
|
|
|
|
default-media-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the media name that is used until the
|
|
media name is changed by a print job command.
|
|
Additional information:
|
|
This string must be one of the MEDIAn-NAME
|
|
objects. The value of this object is saved across
|
|
a power cycle."
|
|
::= { settings-pdl 22 }
|
|
|
|
reprint OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2),
|
|
eAuto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the reprint (jam recovery) setting.
|
|
If eOn, then the device will reprint pages jammed pages.
|
|
If eOff, the device will not attempt to reprint jammed
|
|
pages. If eAuto, a device dependent algorithm (which
|
|
should be documented in the POS) will be used to
|
|
determine if the page gets reprinted. This object
|
|
controls all PDLs, unless a specific PDL supports its
|
|
own reprint control mechanism. To date, only PostScript
|
|
has a PDL reprint control mechanism.
|
|
Additional information:
|
|
Setting this object when the printer is not
|
|
idle, may cause a status of <noError> to be returned, but
|
|
the new value will not take effect until a job boundary
|
|
is reached. If a get is done on object before the job
|
|
boundary is reached, the value last set will be
|
|
returned.
|
|
|
|
When the value is set to eOff, pages will not be stored
|
|
in the printer, and in the event of a paper jam, will
|
|
have to be reprinted. When the value is set to eOn,
|
|
pages will be stored until delivery, therefore, in the
|
|
event of a paper jam, the page will be reprinted.
|
|
|
|
When the value is set to eAuto, the printer will behave
|
|
as though it is eOff when there is less than seven
|
|
megabytes of memory installed in the printer. When
|
|
additional memory is installed, to total at least seven
|
|
megabytes of RAM, the setting of eAuto will behave as
|
|
though it was set to eOn."
|
|
::= { settings-pdl 36 }
|
|
|
|
wide-a4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the wide A4 logical page size
|
|
setting. If eOn, then the margins/printable area of A4
|
|
paper will be changed to allow 80 10-pitch characters to
|
|
be printed on a single line. If eOff then the industry
|
|
standard A4 logical page size is used."
|
|
::= { settings-pdl 37 }
|
|
|
|
dark-courier OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the dark Courier setting. If eOn,
|
|
then the Courier font used will approximate the same
|
|
darkness as the LaserJet III printer. If eOff, then the
|
|
Courier font used will approximate the same darkness as
|
|
the LaserJet 4 printer."
|
|
::= { settings-pdl 38 }
|
|
|
|
default-bits-per-pixel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the number of levels used (per pixel) when
|
|
printing grayscale or color images."
|
|
::= { settings-pdl 39 }
|
|
|
|
pcl-datecode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the PCL firmware date code in yyyymmdd
|
|
format."
|
|
::= { pdl-pcl 1 }
|
|
|
|
pcl-resource-saving-memory-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the amount of resource saving memory
|
|
set aside to hold permanent soft PCL resources.
|
|
Additional information:
|
|
The value returned by this object is the amount of
|
|
Resource Saving memory currently dedicated to PCL.
|
|
|
|
For a PCL-only printer, the value of this object is zero. All memory is
|
|
dedicated to PCL, but it is not shown as such.
|
|
|
|
If Postscript is installed, the default value of this object is as follows:
|
|
0 if RESOURCE-SAVING = eOff.
|
|
0 if less than 8 Megabytes of RAM is in the printer.
|
|
400K bytes if RAM >= 8 Megabytes and RESOURCE-SAVING = eOn.
|
|
400K bytes if RAM = 8 Megabytes and RESOURCE-SAVING = eAuto, plus 100K bytes
|
|
for each Megabyte of RAM over 8 Megabytes.
|
|
|
|
If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource
|
|
Saving memory currently dedicated to PCL. The range of values supported by
|
|
this object are:
|
|
0 bytes (which disables resource saving for PCL)
|
|
400K bytes through (400K bytes + MAXIMUM-RESOURCE-SAVING-MEMORY) in
|
|
increments of 100K bytes.
|
|
If a value is received that is greater than 0 and less than 400K bytes,
|
|
it will be snapped to 400K bytes and a status of
|
|
<noError> returned.
|
|
If an unsupported value greater than 400K bytes is received,
|
|
it will be snapped down to the nearest 100K value
|
|
and a status of <noError> returned.
|
|
|
|
Attempting to set this object when RESOURCE-SAVING is eAuto or eOff will
|
|
cause a status of <genErr> to be returned."
|
|
::= { pdl-pcl 2 }
|
|
|
|
pcl-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the name of the PDL. For PCL, the name is
|
|
`PCL'."
|
|
::= { pdl-pcl 3 }
|
|
|
|
pcl-version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the PDL version."
|
|
::= { pdl-pcl 4 }
|
|
|
|
|
|
pcl-total-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of PCL pages printed by the device.
|
|
Additional information:
|
|
In LaserJet 4050 Series the PCL page count is kept in
|
|
NVRAM, and the NVRAM value is updated at least every
|
|
10 pages. NOTE: The value returned by this object will
|
|
be incremented every page but if power is lost between
|
|
NVRAM updates, up to 9 pages of the page count may be
|
|
lost. The page count counter will be reset to zero
|
|
after 16,777,215 (2^24-1) pages.
|
|
The page count is incremented when a sheet of media is pulled from an input
|
|
tray. A duplex printed sheet will cause this counter to be incremented by
|
|
two."
|
|
::= { pdl-pcl 5 }
|
|
|
|
pcl-default-symbol-set OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eISO60DanishNorwegian(4),
|
|
eISO15Italian(9),
|
|
eISO88591Latin1ECMA94(14),
|
|
eISO11SwedishforNames(19),
|
|
eISO6ASCII(21),
|
|
eISO4UnitedKingdom(37),
|
|
eISO69French(38),
|
|
eISO21German(39),
|
|
eLegal(53),
|
|
eISO88592Latin2ECMA94(78),
|
|
eISO17Spanish(83),
|
|
ePSMath(173),
|
|
eISO88599Latin5ECMA128(174),
|
|
eWindows31Latin5(180),
|
|
eMicrosoftPublishing(202),
|
|
eVenturaMath(205),
|
|
eDeskTop(234),
|
|
eMath8(269),
|
|
eRoman8(277),
|
|
eWindows31Latin2(293),
|
|
ePC8Turkish(308),
|
|
eWindows30Latin1(309),
|
|
ePSText(330),
|
|
ePC8CodePage437(341),
|
|
ePC8DNDanishNorwegian(373),
|
|
ePC850Multilingual(405),
|
|
eVenturaInternational(426),
|
|
eVenturaUS(458),
|
|
ePiFont(501),
|
|
ePC852Latin2(565),
|
|
eWindows31J(619),
|
|
eWindows31Latin1(629)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the default PCL symbol set. The
|
|
enumeration values match the values supported by the PCL
|
|
Symbol Set Code escape sequence, <ESC>*c#R. The binary
|
|
representation of the enumerated value is also matches
|
|
the PML <SymbolSetValue>.
|
|
Additional information:
|
|
The eWindows31J enumeration is only supported
|
|
if a Japanese font SIMM is installed."
|
|
::= { pdl-pcl 11 }
|
|
|
|
|
|
pcl-default-font-height OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the default PCL height. Height is an
|
|
approximate measure of the body of the type in
|
|
centipoints. A centipoint is 1/7200 inch. Height
|
|
applies only to proportional fonts. Point size, in
|
|
points, can be converted to font height, in centipoints,
|
|
by multiplying the point size by 100. The POS indicates
|
|
the supported values. An unsupported value causes the
|
|
printer to use the closest supported value, causing the
|
|
printer to return <noError>.
|
|
''Closest'' means the smallest absolute difference.
|
|
Additional information:
|
|
Supported values range from 400 to 99975, in
|
|
increments of 25 units.
|
|
Setting to an unsupported value causes the
|
|
printer to substitute in a snap value and to
|
|
return <noError> status.
|
|
The snap values are as follow:
|
|
<=400 snaps to 400
|
|
>=99975 snaps to 99975
|
|
Unsupported values in the range 400 to 99975 snap
|
|
DOWN to the previous supported value
|
|
(i.e 25293 snaps to 25275 or 75038 snaps to 75025)."
|
|
::= { pdl-pcl 13 }
|
|
|
|
|
|
pcl-default-font-source OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInternal(1),
|
|
ePermanentSoft(2),
|
|
eRomSimm1(10),
|
|
eRomSimm2(11),
|
|
eRomSimm3(12),
|
|
eRomSimm4(13),
|
|
eRomSimm5(14),
|
|
eUsb1(15),
|
|
eUsb2(16),
|
|
eUsb3(17),
|
|
eUsb4(18)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the value of the default font source
|
|
variable in NVRAM."
|
|
::= { pdl-pcl 14 }
|
|
|
|
|
|
pcl-default-font-number OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the value of the default font number
|
|
variable in NVRAM. Writing an unsupported value causes
|
|
the printer to generate an
|
|
<badValue>.
|
|
Additional information:
|
|
Valid numbers or 0 - 255, but only font numbers that are
|
|
included in the PCL FONT LIST are selectable."
|
|
::= { pdl-pcl 15 }
|
|
|
|
|
|
pcl-default-font-width OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the default PCL font width. Width is
|
|
expressed as the width of a character in centipoints. A
|
|
centipoint is 1/7200 inch. Width applies only to fixed
|
|
space fonts. Pitch, in character per inch, can be
|
|
converted to font width, in centipoints, by dividing
|
|
7200 by the pitch. The POS indicates the supported
|
|
values. An unsupported value causes the printer to use
|
|
the closest supported value, causing the printer to
|
|
return <noError>. ''Closest''
|
|
means the smallest absolute difference.
|
|
Additional information:
|
|
Setting to an unsupported value causes the
|
|
printer to substitue in a snap value (listed below)
|
|
and return <noError> status.
|
|
The snap values for pitch are as follow:
|
|
<=44 snaps to 44
|
|
>=9999 snaps to 9999"
|
|
::= { pdl-pcl 16 }
|
|
|
|
postscript-datecode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the PostScript firmware datecode in
|
|
yyyymmdd format.
|
|
Additional information:
|
|
This object is only supported if PostScript
|
|
option is installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no
|
|
PostScript option installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no PostScript option
|
|
installed."
|
|
::= { pdl-postscript 1 }
|
|
|
|
|
|
postscript-resource-saving-memory-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the amount of resource saving memory
|
|
set aside to hold permanent soft PostScript resources.
|
|
Additional information:
|
|
The value returned by this object is the amount of
|
|
Resource Saving memory currently dedicated to Postscript.
|
|
|
|
If Postscript is installed, the default value of this object is as follows:
|
|
0 if RESOURCE-SAVING = eOff.
|
|
0 if less than 8 Megabytes of RAM is in the printer.
|
|
400K bytes if RAM >= 8 Megabytes and RESOURCE-SAVING = eOn.
|
|
400K bytes if RAM = 8 Megabytes and RESOURCE-SAVING = eAuto, plus 100K bytes
|
|
for each Megabyte of RAM over 8 Megabytes.
|
|
|
|
If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource
|
|
Saving memory currently dedicated to PCL. The range of values supported by
|
|
this object are:
|
|
0 bytes (which disables resource saving for Postscript)
|
|
400K bytes through (400K bytes + MAXIMUM-RESOURCE-SAVING-MEMORY) in
|
|
increments of 100K bytes.
|
|
If a value is received that is greater than 0 and less than 400K bytes,
|
|
it will be snapped to 400K bytes and a status of
|
|
<noError> returned.
|
|
If an unsupported value greater than 400K bytes is received,
|
|
it will be snapped down to the nearest 100K value
|
|
and a status of <noError> returned.
|
|
|
|
Attempting to set this object when RESOURCE-SAVING is eAuto or eOff will
|
|
cause a status of <genErr> to be returned."
|
|
::= { pdl-postscript 2 }
|
|
|
|
postscript-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the name of the PDL. For PostScript, the name
|
|
is `PostScript'.
|
|
Additional information:
|
|
This object is only supported if PostScript
|
|
option is installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no
|
|
PostScript option installed.
|
|
Returns an <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no PostScript option
|
|
installed."
|
|
::= { pdl-postscript 3 }
|
|
|
|
postscript-version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the PDL version.
|
|
Additional information:
|
|
This object is only supported if PostScript
|
|
option is installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no
|
|
PostScript option installed.
|
|
Returns an <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no PostScript option
|
|
installed."
|
|
::= { pdl-postscript 4 }
|
|
|
|
postscript-total-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of PostScript pages printed by the device.
|
|
Additional information:
|
|
This object is only supported if the PostScript
|
|
option is installed.
|
|
In LaserJet 4050 Series the count is kept in NVRAM, and the
|
|
NVRAM value is updated at least every 10
|
|
sheets. NOTE: The value returned by this object will
|
|
be incremented every sheet but if power is lost between
|
|
NVRAM updates up to 9 sheets of the count may be
|
|
lost. The counter will be reset to zero
|
|
after 16,777,215 (2^24-1) pages. "
|
|
::= { pdl-postscript 5 }
|
|
|
|
|
|
postscript-print-errors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the value of the print PostScript
|
|
errors setting. If eOn, PostScript prints an error page
|
|
showing the error encountered and the stack at the time
|
|
of the error.
|
|
Additional information:
|
|
This object is only supported if the PostScript
|
|
option is installed."
|
|
::= { pdl-postscript 11 }
|
|
|
|
postscript-jam-recovery OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the PostScript jam recovery setting.
|
|
If eOn, then the device will reprint PostScript pages,
|
|
if those pages jam.
|
|
Additional information:
|
|
This object is only supported if PostScript
|
|
option is installed."
|
|
::= { pdl-postscript 12 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.4.14
|
|
postscript-defer-media OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object will be used to enable or disable the use of the
|
|
Adobe Postscript Paper Handling Model in the printer firmware.
|
|
By default it is enabled which means that PostScript will
|
|
always defer the media selection to HP Paper Handling Model"
|
|
::= { pdl-postscript 14 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.15.1
|
|
pdf-version OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Contains version of PDF that is supported on the device"
|
|
::= { pdl-pdf 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.15.2
|
|
pdf-total-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of PDF pages printed by the device"
|
|
::= { pdl-pdf 2 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.15.3
|
|
pdf-enabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePDFNotEnabled(1),
|
|
ePDFEnabled(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Used to tell whether the device supports PDF"
|
|
::= { pdl-pdf 3 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.15.4
|
|
pdf-print-errors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Returns or changes the value of the print PDF errors setting.
|
|
If eOn, PDF prints an error page showing the error encountered
|
|
and the stack at the time of the error"
|
|
::= { pdl-pdf 4 }
|
|
|
|
pclxl-total-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Total number of PCLXL pages printed by the device."
|
|
::= { pdl-pclxl 1 }
|
|
|
|
esc-p-datecode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the ESC-P PDL datecode. The datecode
|
|
format is yyyymmdd.
|
|
Additional information:
|
|
This object is only supported if ESC-P option is
|
|
installed.
|
|
Returns an <noSuchName> status if
|
|
attempting to perform a Get on this OID with no ESC-P
|
|
option installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no ESC-P option
|
|
installed."
|
|
::= { pdl-esc-p 1 }
|
|
|
|
|
|
esc-p-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the name of the PDL. For ESC-P, the name is
|
|
`ESC-P'.
|
|
Additional information:
|
|
This object is only supported if ESC-P option is
|
|
installed.
|
|
Returns an <noSuchName> status if
|
|
attempting to perform a Get on this OID with no ESC-P
|
|
option installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no ESC-P option
|
|
installed."
|
|
::= { pdl-esc-p 3 }
|
|
|
|
|
|
esc-p-version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the PDL version.
|
|
Additional information:
|
|
This object is only supported if ESC-P option is
|
|
installed.
|
|
Returns an <noSuchName> status if
|
|
attempting to perform a Get on this OID with no ESC-P
|
|
option installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no ESC-P option
|
|
installed."
|
|
::= { pdl-esc-p 4 }
|
|
|
|
|
|
pjl-password OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns PJL password, if the password is not set (zero).
|
|
If the password is set, then attempting to retrieve the
|
|
password causes an <genErr> to occur
|
|
and will return the <NullValue>."
|
|
::= { pjl 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.8.8.1
|
|
media-number-of-type-supported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Indicates the maximum number of supported media types"
|
|
::= { media-types 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.15.1.
|
|
media-size-supported-driver-n-string OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns the Driver (PJL) string used to specigy a media size,
|
|
for each media size that is supported by a product. PML walk of
|
|
1.4.1.15.1 will return the driver (PJL) name string for each
|
|
media size supported by a product. PML Get of 1.4.1.15.1.X will
|
|
return the driver (PJL) name string of the media size whose PML
|
|
ID maps to X (if it is supported)"
|
|
::= { media-sizes 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.8.2
|
|
fih-extra-pulses-feature OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisable(1),
|
|
eEnable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object allows one to get/set the setting of the FIH EXTRA
|
|
PULSES FEATURE item. This either turns the feature on or off
|
|
based on customer requirement"
|
|
::= { foreign-interface 2 }
|
|
|
|
print-density OBJECT-TYPE
|
|
SYNTAX INTEGER(1..5)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the print density setting. Print
|
|
density is the instantaneous amount of marking agent
|
|
applied to the paper while printing. A value of zero
|
|
has the lowest print density, yielding a lighter page.
|
|
A value of 10 has the highest print density, yielding a
|
|
darker page. Each POS should document what values in
|
|
the 0 to 10 range are supported.
|
|
Additional information:
|
|
When this value is written, the page pipeline
|
|
will be flushed (all pages being printed are completed, no
|
|
new ones are started), the new density setting is set and
|
|
printing resumes. The acutal change in print density may be
|
|
gradual over several pages.
|
|
The supported values are 1 through 5. Setting to an
|
|
unsupported value causes the printer to substitue in a
|
|
a snap value and to return <noError>
|
|
status. The snap values are as follows:
|
|
<1 snaps to 1
|
|
>5 snaps to 5."
|
|
::= { settings-prt-eng 5 }
|
|
|
|
|
|
transfer-setting OBJECT-TYPE
|
|
SYNTAX INTEGER(100..200)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set the object will cause the transfer setting of the
|
|
device to be changed to the nearest appropriate value. When
|
|
the object is read it will return the current transfer
|
|
setting. Each engine will have different supported values.
|
|
The object should snap to the nearest supported value.
|
|
Different products could use this value in different ways.
|
|
Typically, this value would be a voltage on an EP system,
|
|
but could be a pressure level on an inkjet.
|
|
Additional information:
|
|
This setting is a voltage adjustment in the LaserJet
|
|
2200. Any value >= 150 snaps to 200."
|
|
::= { settings-prt-eng 8 }
|
|
|
|
|
|
separation-setting OBJECT-TYPE
|
|
SYNTAX INTEGER(100..200)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set this object will cause the separation setting of
|
|
the device to be changed to the nearest appropriate value.
|
|
When the object is read it will return the current separation
|
|
setting. Each engine will have different supported values.
|
|
The object should snap to the nearest supported value.
|
|
Different products could use this value in different ways.
|
|
Typically, this value would be a voltage in an EP system,
|
|
but could be some other parameter on an inkjet. The device
|
|
POS will specify supported values, any snap behavior and
|
|
will detail the product specific meaning of
|
|
'device separation'.
|
|
Additional information:
|
|
This object changes the charge so the media does not
|
|
curl too much causing the media to jam under the cartridge.
|
|
Any value >= 150 snaps to 200."
|
|
::= { settings-prt-eng 13 }
|
|
|
|
not-ready-destination-print-engine OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the print engine sub-system in the device
|
|
is not ready. If there are no items in the collection
|
|
(i.e. no bits are set), then the print engine sub-
|
|
system is ready. If there is an item present, then the
|
|
item indicates what is causing the print engine sub-
|
|
system to be not ready. cDoorOpen is in the collection
|
|
if one or more access panels are open. If the device
|
|
contains more than one access panel, then NOT-READY-
|
|
PRINT-ENGINE-DOOR indicates which access panel(s) are
|
|
open. cInternalMediaJam is in the collection if one or
|
|
more pieces of media are jammed inside the device. If
|
|
the media is jammed at an input tray, cTrayMediaJam is
|
|
in the collection, and if the device has more than one
|
|
input tray, then NOT-READY-MEDIA-JAM-AT-TRAY indicates
|
|
which tray has a media jam. If the media is jammed at
|
|
an output bin, cBinMediaJam is in the collection, and if
|
|
the device has more than one output bin, then NOT-READY-
|
|
MEDIA-JAM-AT-BIN indicates which bin has a media jam.
|
|
cRequestedMediaUnavailable is in the collection if the
|
|
current print job requires media that is not available.
|
|
cTrayEmpty is in the collection if the current print job
|
|
requires media from an input tray that is empty. If the
|
|
device has more than one input tray, then NOT-READY-
|
|
TRAY-EMPTY indicates which tray is empty.
|
|
cOutputBinFull is in the collection if an output bin is
|
|
full. If the device has more than one output bin, then
|
|
NOT-READY-BIN-FULL indicates which bin is full.
|
|
cManualFeedMedia is in the collection if the device is
|
|
waiting for media to manually be fed.
|
|
cMarkingAgentMissing is in the collection if a marking
|
|
agent (toner cartridge, ink pen, etc.) is missing. If
|
|
the device has more than one marking agent, then NOT-
|
|
READY-MARKING-AGENT-MISSING indicates which marking
|
|
agent is missing. cMarkingAgentOut is in the collection
|
|
if the device is not ready due to one or more marking
|
|
agents being low or out. If the device has more than
|
|
one marking agent, then NOT-READY-MARKING-AGENT-LOW-OR-
|
|
OUT indicates which marking agent is low or out.
|
|
cIncorrectMarkingAgent is in the collection if the
|
|
device detects that an incorrect marking agent is
|
|
installed. If the device has more than one marking
|
|
agent, then NOT-READY-INCORRECT-MARKING-AGENT indicates
|
|
which marking agent location is loaded with the wrong
|
|
type of marking agent. cTrayMissing is in the
|
|
collection if the device is not ready because one or
|
|
more trays are not installed. If the device has more
|
|
than one input tray, then NOT-READY-TRAY-MISSING
|
|
indicates which tray is missing. cDeviceSpecific is in
|
|
the collection if one or more items are in either NOT-
|
|
READY-LASER-PRINT-ENGINE or NOT-READY-DESTINATION-
|
|
INKJET-PRINT-ENGINE-NOT-READY. cMediaPickMisfeed is in
|
|
the collection if the print engine detects the tray is
|
|
not empty, but can not pick up a sheet of media from
|
|
that tray. cMarkingAgentFailure indicates there is a
|
|
failure with a marking agent and it may need to be
|
|
replaced. If the device supports more than one marking
|
|
agent, then the NOT-READY-MARKING-AGENT-FAILURE object
|
|
indicates all the marking agents that have failed. The
|
|
POS will indicate the marking agent failure recovery
|
|
process, if any."
|
|
::= { status-prt-eng 1 }
|
|
|
|
override-media-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets a string identifying the media name that is to be
|
|
used in place of the currently requested media. The
|
|
substitution will continue until another media is
|
|
selected. If set to a named media that is not currently
|
|
available the requested media is not overridden.
|
|
Additional information:
|
|
When a request is received to print on a size and
|
|
type of media that is not currently available, this
|
|
object contains the desired media name as set by the
|
|
print job. This object should be set to a media name
|
|
that is currently available in the printer. If a
|
|
paper mount request is not pending, attempting to get
|
|
or set this object will cause
|
|
<noSuchName> to be returned.
|
|
Setting this object to a string other than one of the
|
|
MEDIAn-NAME objects (MEDIA-NAMES-AVAILABLE is applied)
|
|
will cause a status of <badValue>
|
|
to be returned."
|
|
::= { settings-prt-eng 2 }
|
|
|
|
not-ready-laser-print-engine OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the laser print engine sub-system in the
|
|
device is not ready. If there are no items in the
|
|
collection (i.e. no bits are set), then the laser print
|
|
engine sub-system is ready. If there is an item
|
|
present, then the item indicates what is causing the
|
|
laser print engine sub-system to be not ready."
|
|
::= { status-prt-eng 3 }
|
|
|
|
total-engine-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of pages printed by the device. POS
|
|
indicates if the total engine page count is kept in
|
|
NVRAM, and the maximum supported value before the page
|
|
count rolls over to zero.
|
|
Additional information:
|
|
This object is stored in NVRAM. The maximum value of
|
|
this count is 1000000 before it rolls over to zero."
|
|
::= { status-prt-eng 5 }
|
|
|
|
|
|
total-mono-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Total number of black pages printed by the device.
|
|
Additional information:
|
|
Total number of mono pages printed by the device."
|
|
::= { status-prt-eng 6 }
|
|
|
|
total-color-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..4294967296)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of color pages printed by the device.
|
|
Additional information:
|
|
Any page with one or more color pixels is counted as
|
|
a color page. Pages that only contain black marks are not
|
|
counted by this object.
|
|
The counter will roll over to zero after 4,294,967,296 pages.
|
|
Each side of a duplexed sheet of media will be counted
|
|
independently based on the criteria listed above."
|
|
::= { status-prt-eng 7 }
|
|
|
|
status-destination-print-engine OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if part of the print engine sub-system is not
|
|
functional, but the non-functional component(s) are not
|
|
currently required to print."
|
|
::= { status-prt-eng 8 }
|
|
|
|
duplex-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of sheets of media that have been duplex
|
|
printed. A sheet is counted if it travels through the
|
|
duplex page path, regardless of whether or not marks are
|
|
made on the page. The POS will indicate if the value is
|
|
kept in NVRAM.
|
|
Additional information:
|
|
In LaserJet 4050 Series the count is kept in
|
|
NVRAM however the NVRAM value is only updated every 10
|
|
sheets. NOTE: The value returned by this object will be
|
|
incremented every sheet but if power is lost between
|
|
NVRAM updates up to 9 sheets of the count may be
|
|
lost. The counter will be reset to zero
|
|
after 16,777,215 (2^24-1) pages. "
|
|
::= { status-prt-eng 22 }
|
|
|
|
print-engine-revision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Print engine revision string.
|
|
Additional information:
|
|
The symbol set for this string is Roman-8. Converts
|
|
engine revision number to a string and returns it."
|
|
::= { status-prt-eng 26 }
|
|
|
|
print-engine-jam-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of pages jammed in the print engine's life
|
|
time. The POS indicates if the total jam count is kept in
|
|
NVRAM and the maximum supported value before the jam count
|
|
rolls over to zero.
|
|
Additional information:
|
|
This object is stored in NVRAM. The maximum value of
|
|
this count is 65000 before it rolls over to zero."
|
|
::= { status-prt-eng 34 }
|
|
|
|
|
|
print-engine-mispick-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of pages mispicked in the print engine's life
|
|
time. The POS indicates if the total mispick count is kept in
|
|
NVRAM and the maximum supported value before the mispick count
|
|
rolls over to zero.
|
|
Additional information:
|
|
This object is stored in NVRAM. The maximum value of
|
|
this count is 65000 before it rolls over to zero."
|
|
::= { status-prt-eng 35 }
|
|
|
|
|
|
default-manual-feed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the default manual feed value used by
|
|
the PDLs."
|
|
::= { settings-intray 4 }
|
|
|
|
mp-tray OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eCassette(2),
|
|
eFirst(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the value of the multi-purpose (MP)
|
|
tray configuration variable. The MP tray can be
|
|
configured to operate as an additional input tray
|
|
(eCassette), a manual feed slot (eManual), or in a
|
|
manner compatible with the LaserJet III manual feed slot
|
|
(eFirst). If configured for eFirst, if media is present
|
|
in the MP tray, that media is used (assuming the size
|
|
matches and the print job didn't specify another tray)
|
|
until the MP tray is empty.
|
|
Additional information:
|
|
The MP tray can be configured for use either as a paper
|
|
cassette or as a priority manual feed tray. When the tray is configured as a manual feed tray, unsolicited status messages are not generated when there is no
|
|
paper in the tray. LaserJet 4050 Series will pull media from TRAY 1 only if there is
|
|
a sheet present and it matches the needed size and type."
|
|
::= { settings-intray 5 }
|
|
|
|
tray-lock OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the list of locked input trays. The
|
|
printer only pulls media from a locked input tray when
|
|
the input tray is specifically requested by the print
|
|
job.
|
|
Additional information:
|
|
The HP LaserJet 2100 Series will pull paper from a
|
|
locked tray if that tray is specifically requested or if
|
|
the user presses the Go button on a paper mount override
|
|
and there is no paper available in an unlocked tray.
|
|
|
|
There must always be at least one unlocked tray. When
|
|
no optional lower cassette is installed and one tray is
|
|
locked, an attempt to lock the other tray will result in
|
|
the first tray unlocking. When the optional cassette is
|
|
installed and two trays are locked, an attempt to lock
|
|
the third will fail with a return status of
|
|
<badValue> and a return value
|
|
containing the collection of previously locked trays."
|
|
::= { settings-intray 6 }
|
|
|
|
|
|
custom-paper-dim-unit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTenThousandthsOfInches(3),
|
|
eMicrometers(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The units of measure used to specify the width and
|
|
height of the printer's custom paper. The unit of
|
|
measure of eTenThousandthsOfInches is 0.0001 inches.
|
|
Additional information:
|
|
The only valid values for this object are
|
|
eTenThousandthsOfInches (3), and eMicrometers (4). The
|
|
data for this object is stored in NVRAM."
|
|
::= { settings-intray 7 }
|
|
|
|
custom-paper-feed-dim OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the printer's custom paper dimension in the feed
|
|
direction (direction parallel to the direction of paper
|
|
feeding). The value for this object is specified in
|
|
micrometers or tenthousandths of an inch, depending upon
|
|
the value of CUSTOM-PAPER-DIM-UNIT. The valid range is
|
|
engine-dependent and should be documented in the POS for
|
|
each product.
|
|
Additional information:
|
|
The valid range for LaserJet 4000 Series is 50000 to 140000 if
|
|
CUSTOM-PAPER-DIM-UNIT is eTenThousandthsOfInches or
|
|
127000 to 355600 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers.
|
|
Attempts to set this object outside the valid range will result
|
|
in a return value of <badValue>."
|
|
::= { settings-intray 8 }
|
|
|
|
|
|
custom-paper-xfeed-dim OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the printer's custom paper dimension in the cross-
|
|
feed direction (direction ninety degrees relative to the
|
|
direction of paper feeding). The value for this object
|
|
is specified in micrometers or tenthousandths of an
|
|
inch, depending upon the value of CUSTOM-PAPER-DIM-UNIT.
|
|
The valid range is engine-dependent and should be
|
|
documented in the POS for each product.
|
|
Additional information:
|
|
The valid range for LaserJet 4000 Series is 30000 to 85000 if
|
|
CUSTOM-PAPER-DIM-UNIT is eTenThousandthsOfInches or
|
|
76200 to 215900 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers.
|
|
Attempts to set this object outside the valid range will result
|
|
in a return value of <badValue>."
|
|
::= { settings-intray 9 }
|
|
|
|
not-ready-tray-missing OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which trays are not currently installed that
|
|
is caused the device to be not ready."
|
|
::= { status-intray 1 }
|
|
|
|
|
|
not-ready-tray-empty OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which trays contain no media causing the
|
|
device to be not ready. Some devices may treat tray
|
|
missing as a tray empty condition."
|
|
::= { status-intray 2 }
|
|
|
|
|
|
status-tray-missing OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which trays are not currently installed that
|
|
is caused the device to be in a warning condition."
|
|
::= { status-intray 3 }
|
|
|
|
|
|
status-tray-empty OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which trays contain no media causing the
|
|
device to be in a warning condition. Some devices may
|
|
treat tray missing as a tray empty condition."
|
|
::= { status-intray 4 }
|
|
|
|
low-marking-agent-processing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eStop(1),
|
|
eCont(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes how the device processes a low
|
|
marking agent event. If eCont, then the device
|
|
continues to print. If eStop, then the device stops
|
|
until a continue event occurs."
|
|
::= { settings-marking-agent 3 }
|
|
|
|
|
|
default-ret OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eLight(2),
|
|
eMedium(3),
|
|
eDark(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the Resolution Enhancement Technology
|
|
setting. Devices that only support eOff and on should
|
|
map all other values to on and always return the same
|
|
non-eOff value to indicate on. The list of supported
|
|
values should be documented in the device POS.
|
|
Additional information:
|
|
Setting this object may cause a status of <noError> to be
|
|
returned, but the new value will not take effect until a job
|
|
boundary is reached. If a get is done on object before the job
|
|
boundary is reached, the value last set will be returned.
|
|
The value of this object is saved over a powercycle."
|
|
::= { imaging 5 }
|
|
|
|
|
|
default-print-quality OBJECT-TYPE
|
|
SYNTAX INTEGER(0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the default print quality. A value of
|
|
zero has the lowest print quality. A value of 100 has
|
|
the highest print quality. Each POS should document
|
|
what values in the 0 to 100 range are supported.
|
|
Additional information:
|
|
In LaserJet 4050 Series, the supported values are 0 and
|
|
100. A value of zero has the lowest print
|
|
quality(ECONOMODE=ON), thus minimizes the amount of
|
|
toner used to print a page. A value of 100 has the
|
|
highest print quality (ECONOMODE=OFF), thus uses more
|
|
toner to print a page. Setting to an unsupported value
|
|
outside of the 0 to 100 range causes the printer to
|
|
return <badValue> status.
|
|
Setting to an unsupported value inside of the 0 to
|
|
100 range causes the printer to substitute in a snap
|
|
value (listed below) and to return
|
|
<noError> status.
|
|
The snap values are as follow:
|
|
0 to 50 snap to 0
|
|
51 to 100 snap to 100"
|
|
::= { imaging 7 }
|
|
|
|
|
|
gdStatusLineState OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This describes the line state of the peripheral.
|
|
When non-zero, the peripheral is off-line. When
|
|
zero the peripheral is on-line."
|
|
::= { gdStatusEntry 1 }
|
|
|
|
|
|
gdStatusPaperState OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This describes the state of the paper on the peripheral.
|
|
When non-zero, the peripheral has a paper problem. When
|
|
zero, the peripheral does not have a paper problem."
|
|
::= { gdStatusEntry 2 }
|
|
|
|
|
|
gdStatusInterventionState OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This describes the intervention state of the
|
|
peripheral. When non-zero, the peripheral requires
|
|
human intervention to continue working. When
|
|
zero, it requires no assistance."
|
|
::= { gdStatusEntry 3 }
|
|
|
|
gdStatusNewMode OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This indicates to which read channel state the
|
|
card should move. When non-zero, the card should
|
|
indicate that the read channel is idle. When zero,
|
|
the card should indicate that the read channel is
|
|
operating. This object is Lan Manager io channel
|
|
specific. It is kept here for backward compatibility.
|
|
|
|
Starting with firmware release X.20.06 and subsequent
|
|
releases, this object is obsolete as it provides no
|
|
relevant data for the new hardware architecture.
|
|
No current supported applications use this object."
|
|
::={ gdStatusEntry 4 }
|
|
|
|
gdStatusConnectionTerminationAck OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This indicates whether the peripheral is waiting for
|
|
the Connection termination ACK. When non-zero, it
|
|
is waiting. When zero, it is not waiting."
|
|
::={ gdStatusEntry 5 }
|
|
|
|
gdStatusPeripheralError OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the error code from the peripheral."
|
|
::= { gdStatusEntry 6 }
|
|
|
|
|
|
gdStatusPaperOut OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral is out of paper.
|
|
off (0),
|
|
paper-out-or-paper-mount (1),
|
|
manual-paper-feed-needed (2)
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 8 }
|
|
|
|
|
|
gdStatusPaperJam OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral has a paper jam.
|
|
off (0),
|
|
paper-jam(1)
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 9 }
|
|
|
|
|
|
gdStatusTonerLow OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral has a low toner condition.
|
|
off (0),
|
|
toner-low (1),
|
|
no-toner-cartridge (2)
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 10 }
|
|
|
|
|
|
gdStatusPagePunt OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral did not receive data fast
|
|
enough to keep up with the print engine when generating a page.
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 11 }
|
|
|
|
|
|
gdStatusMemoryOut OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral did not have enough memory
|
|
to render an image on a page.
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 12 }
|
|
|
|
|
|
gdStatusIoActive OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral is processing data from
|
|
this I/O interface card. For some peripherals, such as the
|
|
HP LaserJet IIISi printer or HP DesignJet plotter,
|
|
this value is always a zero (0).
|
|
|
|
For X.20.06 firmware and later firmware releases, this object is
|
|
not relevant. In order not to break legacy applications which call this
|
|
object in multi-varbind requests, this value is always zero (0)."
|
|
::= { gdStatusEntry 13 }
|
|
|
|
|
|
gdStatusBusy OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral is busy processing
|
|
print/plot data.
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 14 }
|
|
|
|
|
|
gdStatusWait OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral is waiting for print/plot
|
|
data to process.
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 15 }
|
|
|
|
|
|
gdStatusInitialize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral is initializing or
|
|
warming up.
|
|
off (0),
|
|
initializing (1),
|
|
warm-up(2)
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 16 }
|
|
|
|
|
|
gdStatusDoorOpen OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral cover or door is open.
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 17 }
|
|
|
|
|
|
gdStatusPrinting OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral is printing or otherwise
|
|
marking or moving paper.
|
|
off (0),
|
|
ordinary-page (1),
|
|
test-fonts-config-or-start-page (2)
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 18 }
|
|
|
|
|
|
gdStatusPaperOutput OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates that the peripheral has a paper output problem
|
|
such as the output storage bin being full.
|
|
off (0),
|
|
output-storage-full (1)
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this value is always a zero (0)."
|
|
::= { gdStatusEntry 19 }
|
|
|
|
gdStatusReserved OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..13))
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This is the reserved area that is not currently
|
|
used, but will allow for growth within the gdStatusEntry table."
|
|
::={ gdStatusEntry 20 }
|
|
|
|
gdStatusNovBusy OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This indicates if this channel is active. If the
|
|
value is 0 then this channel is active or the peripheral
|
|
is idle. If this value is non-zero then another channel
|
|
is active. This is the Novell io channel"
|
|
::={ gdStatusEntry 21 }
|
|
|
|
gdStatusLlcBusy OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This indicates if this channel is active. If the
|
|
value is 0 then this channel is active or the peripheral
|
|
is idle. If this value is non-zero then another channel
|
|
is active. This is the LLC io channel"
|
|
::={ gdStatusEntry 22 }
|
|
|
|
gdStatusTcpBusy OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This indicates if this channel is active. If the
|
|
value is 0 then this channel is active or the peripheral
|
|
is idle. If this value is non-zero then another channel
|
|
is active. This is the TCP io channel"
|
|
::={ gdStatusEntry 23 }
|
|
|
|
gdStatusAtBusy OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This indicates if this channel is active. If the
|
|
value is 0 then this channel is active or the peripheral
|
|
is idle. If this value is non-zero then another channel
|
|
is active. This is the Apple talk io channel"
|
|
::={ gdStatusEntry 24 }
|
|
|
|
|
|
gdStatusBytes OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of valid bytes in the gdStatusEntry
|
|
array."
|
|
::= { generalDeviceStatus 1 }
|
|
|
|
gdStatusDisplay OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"The string diplayed on the peripheral front panel.
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this is always a zero length string."
|
|
::={ generalDeviceStatus 3 }
|
|
|
|
gdStatusJobName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"The current job name set by the peripheral.
|
|
For some peripherals, such as the HP LaserJet IIISi printer
|
|
or HP DesignJet plotter, this is always a zero length string."
|
|
::={ generalDeviceStatus 4 }
|
|
|
|
gdStatusSource OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"A string indicating the name of the physical port or protocol
|
|
the printer is currently getting data from."
|
|
::={ generalDeviceStatus 5 }
|
|
|
|
gdStatusPapstatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"A string indicating the Appletalk papstatus response."
|
|
::={ generalDeviceStatus 6 }
|
|
|
|
gdStatusId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"A formatted string describing this peripheral."
|
|
::={ generalDeviceStatus 7 }
|
|
|
|
gdStatusDisplayCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This is the display code that the peripheral uses
|
|
to tell the card what type of display the front
|
|
panel of the printer is.
|
|
|
|
Starting with firmware release X.20.06 and subsequent
|
|
releases, this object is obsolete as it provides no
|
|
relevant data for the new hardware architecture.
|
|
No current supported applications use this object."
|
|
::={ generalDeviceStatus 8 }
|
|
|
|
gdStatusNlsCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"This value is the representation of what native
|
|
language the printer is in currently."
|
|
::={ generalDeviceStatus 9 }
|
|
|
|
gdStatusJobTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This value represents (in seconds) the maximum time of
|
|
inactivity which must elapse before the JetDirect card
|
|
switches from the current network protocol to another when
|
|
a normal end of job is not detected."
|
|
::={ generalDeviceStatus 10 }
|
|
|
|
gdStatusPjlUstatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"This object will enable/disable PJL ustatus.
|
|
disabled (0),
|
|
enabled (1)"
|
|
::={ generalDeviceStatus 11 }
|
|
|
|
gdStatusLaaSupport OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"This value represents what protocols Locally Administered
|
|
addressing is supported over. This is currently 0 for
|
|
802.3 cards and 7 for 802.5 cards. LAA is not supported
|
|
on 802.3. The value is a mask of bits, 1 for each of the
|
|
protocols below.
|
|
+-----------------------------------------------+
|
|
| NA | NA | NA | NA | NA | TCP | LLC | NOV |
|
|
+-----------------------------------------------+"
|
|
::={ generalDeviceStatus 12 }
|
|
|
|
|
|
gdPasswords OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"This object is used as a 256 byte NVRAM area for JetAdmin. It
|
|
is completely managed by JetAdmin. Initially it is initialized
|
|
to all zeros. A coldboot will re-initialize to all zeros."
|
|
::={ generalDeviceStatus 13 }
|
|
|
|
gdStatusAtPrinterName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current --
|
|
DESCRIPTION
|
|
"The AppleTalk name of the printer."
|
|
::={ generalDeviceStatus 18 }
|
|
|
|
gdStatusAtPrinterType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete --
|
|
DESCRIPTION
|
|
"The AppleTalk type of the printer."
|
|
::={ generalDeviceStatus 19 }
|
|
|
|
photo-access-card-error OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePhotoCardAccessNoError(0),
|
|
ePhotoCardSmartMediaUpsideDown(1),
|
|
ePhotoCardMediaNotFullyInserted(2),
|
|
ePhotoCardMoreThenOneInSlots(3),
|
|
ePhotoCardReadError(4),
|
|
ePhotoCardRemovedWhileReading(5),
|
|
ePhotoCardBadFileWhilePrinting(6),
|
|
ePhotoCardNotInSlot(7),
|
|
ePhotoCardContainsNoPhotos(8),
|
|
ePhotoCardWriteError(9),
|
|
ePhotoCardRemovedWhileWriting(10),
|
|
ePhotoCardUnknownError(999)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Specifies the error reason for most recent unsucessful photo
|
|
card access.
|
|
Additional information:
|
|
Specifies the error reason for most recent unsucessful photo
|
|
card access."
|
|
::= { photo-job 2 }
|
|
|
|
|
|
photo-default-num-copies OBJECT-TYPE
|
|
SYNTAX INTEGER(1..99)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the default number of copies to be printed
|
|
during photo application print jobs. This value is saved over a
|
|
power cycle.
|
|
Additional information:
|
|
Reads or writes the default number of copies to be
|
|
printed during photo application print jobs. This value is
|
|
saved over a power cycle."
|
|
::= { settings-photo-job 1 }
|
|
|
|
|
|
photo-job-num-copies OBJECT-TYPE
|
|
SYNTAX INTEGER(1..99)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the number of copies to be printed during the
|
|
next photo application print job. This value is not saved over
|
|
power cycles.
|
|
Additional information:
|
|
Reads or writes the number of copies to be printed
|
|
during the next photo application print job. This value is
|
|
not saved over a power cycle."
|
|
::= { settings-photo-job 2 }
|
|
|
|
|
|
photo-job-media-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSLetter(2),
|
|
eISOandJISA4(26),
|
|
ePhoto4x6(76)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the default media size to be used during the
|
|
next photo application print job. This value is not saved over
|
|
power cycles.
|
|
Additional information:
|
|
Reads or writes the default media size to be
|
|
used during the next photo application print job. This
|
|
value is not saved over a power cycle."
|
|
::= { settings-photo-job 4 }
|
|
|
|
|
|
photo-job-media-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the media type to be used on the next photo
|
|
application print job. This value is not saved over power
|
|
cycles.
|
|
Additional information:
|
|
Reads or writes the media type to be used on the next
|
|
photo application print job. This value is not saved over a
|
|
power cycle."
|
|
::= { settings-photo-job 6 }
|
|
|
|
|
|
photo-image-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eThumbnail(1),
|
|
eWallet(2),
|
|
e3halfx5in(3),
|
|
e3x4in(4),
|
|
e4x6in(5),
|
|
e5x7in(6),
|
|
e6x8in(7),
|
|
e8x10in(8),
|
|
e6x8cm(9),
|
|
e7x10cm(10),
|
|
e9x13cm(11),
|
|
e10x15cm(12),
|
|
e13x18cm(13),
|
|
e15x21cm(14),
|
|
e18x24cm(15),
|
|
e20x25cm(16),
|
|
eFullPage(17),
|
|
ePanoramic(18)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the default image size to be used during photo
|
|
application print jobs. This value is saved over power cycles.
|
|
Additional information:
|
|
Reads or writes the default image size to be
|
|
used during photo application print jobs. This value is
|
|
saved over a power cycle. Valid image sizes are determined
|
|
by the PHOTO-IMAGE-SIZE-SET pml object."
|
|
::= { settings-photo-job 7 }
|
|
|
|
|
|
photo-job-image-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eThumbnail(1),
|
|
eWallet(2),
|
|
e3halfx5in(3),
|
|
e3x4in(4),
|
|
e4x6in(5),
|
|
e5x7in(6),
|
|
e6x8in(7),
|
|
e8x10in(8),
|
|
e6x8cm(9),
|
|
e7x10cm(10),
|
|
e9x13cm(11),
|
|
e10x15cm(12),
|
|
e13x18cm(13),
|
|
e15x21cm(14),
|
|
e18x24cm(15),
|
|
e20x25cm(16),
|
|
eFullPage(17),
|
|
ePanoramic(18)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the image size to be used during the next photo
|
|
application print job. This value is not saved over power
|
|
cycles.
|
|
Additional information:
|
|
Reads or writes the image size to be used during
|
|
the next photo application print job. This value is not
|
|
saved over a power cycle. Valid image sizes are determined
|
|
by the PHOTO-IMAGE-SIZE-SET pml object."
|
|
::= { settings-photo-job 8 }
|
|
|
|
|
|
photo-select-images OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the list of images to print during the next
|
|
photo application print job. Each image number or number range
|
|
must be separated by a comma. The image number corresponds to
|
|
the location of the file on the image card. For example, if
|
|
there are 10 images on the photo card, then you could select
|
|
'1-10' or '1,2,3,4,5' or '1,2,3,4-9'. The same image number can
|
|
also appear multiple times in the list. i.e.
|
|
'1,2,2,2,3,3,4,4,5'. This value is not saved over power cycles
|
|
and only applies to the next job.
|
|
Additional information:
|
|
Reads or writes the list of images to print
|
|
during the next photo application print job. Each image
|
|
number or number range must be separated by a comma. The
|
|
image number corresponds to the location of the file on
|
|
the image card. For example, if there are 10 images on
|
|
the photo card, then you could select 1-10 or 1,2,3,4,5 or
|
|
1,2,3,4-9. The same image number can also appear multiple
|
|
times in the list. i.e. 1,2,2,2,3,3,4,4,5. This value is
|
|
not saved over a power cycle, and only applies to the next
|
|
job."
|
|
::= { settings-photo-job 9 }
|
|
|
|
|
|
photo-images-on-card OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Reads the number of printable photo images found on the
|
|
inserted memory card. If 0, then no images were found, or the
|
|
card was not properly inserted.
|
|
Additional information:
|
|
Reads the number of printable photo images found
|
|
on the inserted memory card. If 0, then no images were
|
|
found, or the card was not properly inserted."
|
|
::= { settings-photo-job 10 }
|
|
|
|
|
|
photo-job-source OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePhotoPrintProofSheet(1),
|
|
ePhotoScanProofSheet(2),
|
|
ePhotoPrintColorJob(3),
|
|
ePhotoPrintMonochromeJob(4),
|
|
ePhotoPrintIndexPrint(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls initiating photo application features.
|
|
Additional information:
|
|
Controls initiating photo application features."
|
|
::= { settings-photo-job 11 }
|
|
|
|
|
|
photo-color-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the page count for color pages printed by the
|
|
photo application. This value is saved over power cycles.
|
|
Additional information:
|
|
Reads or writes the page count for color pages
|
|
printed by the photo application. This value is saved over
|
|
a power cycle."
|
|
::= { settings-photo-job 12 }
|
|
|
|
|
|
photo-mono-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the page count for monochrome pages printed by
|
|
the photo application. This value is saved over power cycles.
|
|
Additional information:
|
|
Reads or writes the page count for monochrome pages
|
|
printed by the photo application. This value is saved over
|
|
a power cycle."
|
|
::= { settings-photo-job 13 }
|
|
|
|
|
|
photo-image-size-set OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eImageSizeSetInch1(1),
|
|
eImageSizeSetInch2(2),
|
|
eImageSizeSetCentimeter1(3),
|
|
eImageSizeSetCentimeter2(4),
|
|
eImageSizeSetCentimeter3(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This is only writable in service mode. This object changes the
|
|
set of valid image sizes for the device. The image sizes groups
|
|
are as follows:
|
|
eImageSizeSetInch1: Wallet, 3x4in, 3 1/2 x 5in, 4x6in,
|
|
5x7in, 8x10in, full page
|
|
eImageSizeSetInch2: Wallet, 3 1/2 x 5in, 4x6in, 5x7in,
|
|
6x8in, 8x10in, full page
|
|
eImageSizeSetCentimeter1: 6x8cm, 7x10cm, 9x13cm, 10x15cm,
|
|
13x18cm, 15x21cm, 20x25cm, full page
|
|
eImageSizeSetCentimeter2: 7x10cm, 9x13cm, 10x15cm, 13x18cm,
|
|
20x25cm, full page
|
|
eImageSizeSetCentimeter3: 6x8cm, 9x13cm, 10x15cm, 13x18cm,
|
|
15x21cm, 18x24cm, 20x25cm, full page .
|
|
Additional information:
|
|
This is only writable in service mode. This object
|
|
changes the set of valid image sizes for the device. The image
|
|
sizes groups are as follows:
|
|
eImageSizeSetInch1: Thumbnail, Wallet, 3x4in, 3 1/2 x 5in, 4x6in,
|
|
5x7in, 8x10in, full page, panorama
|
|
eImageSizeSetInch2: Thumbnail, Wallet, 3 1/2 x 5in, 4x6in, 5x7in,
|
|
6x8in, 8x10in, full page, panorama
|
|
eImageSizeSetCentimeter1: Thumbnail, 6x8cm, 7x10cm, 9x13cm, 10x15cm,
|
|
13x18cm, 15x21cm, 20x25cm, full page, panorama
|
|
eImageSizeSetCentimeter2: Thumbnail, 7x10cm, 9x13cm, 10x15cm, 13x18cm,
|
|
20x25cm, full page, panorama
|
|
eImageSizeSetCentimeter3: Thumbnail, 6x8cm, 9x13cm, 10x15cm, 13x18cm,
|
|
15x21cm, 18x24cm, 20x25cm, full page, panorama"
|
|
::= { settings-photo-job 15 }
|
|
|
|
|
|
photo-clear-counts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eClearPageCounts(1),
|
|
eClearInsertCounts(2),
|
|
eClearAllCounts(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "writing this object causes the page counts, insert counts, or
|
|
all photo counts to be cleared and reset to 0.
|
|
Additional information:
|
|
writing this object causes the page counts, insert counts, or all photo counts
|
|
to be cleared and reset to 0."
|
|
::= { settings-photo-job 18 }
|
|
|
|
|
|
photo-compact-flash-insert-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the count for the number of times a compact
|
|
flash memory card has been inserted in the device. This value
|
|
is saved over a power cycle.
|
|
Additional information:
|
|
reads or writes the count for the number of times a compact flash memory card
|
|
has been inserted in the device. This value is saved over a power cycle."
|
|
::= { settings-photo-job 19 }
|
|
|
|
|
|
photo-memory-stick-insert-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the count for the number of times a memory
|
|
stick memory card has been inserted in the device. This value
|
|
is saved over a power cycle.
|
|
Additional information:
|
|
reads or writes the count for the number of times a memory stick memory card
|
|
has been inserted in the device. This value is saved over a power cycle."
|
|
::= { settings-photo-job 20 }
|
|
|
|
|
|
photo-memory-stick-pro-insert-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the count for the number of times a memory
|
|
stick pro memory card has been inserted in the device. This
|
|
value is saved over a power cycle.
|
|
Additional information:
|
|
reads or writes the count for the number of times a memory stick pro memory card
|
|
has been inserted in the device. This value is saved over a power cycle."
|
|
::= { settings-photo-job 21 }
|
|
|
|
|
|
photo-smart-media-insert-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the count for the number of times a smart media
|
|
memory card has been inserted in the device. This value is
|
|
saved over a power cycle.
|
|
Additional information:
|
|
reads or writes the count for the number of times a compact flash memory card
|
|
has been inserted in the device. This value is saved over a power cycle."
|
|
::= { settings-photo-job 22 }
|
|
|
|
|
|
photo-secure-digital-insert-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the count for the number of times a secure
|
|
digital memory card has been inserted in the device. This value
|
|
is saved over a power cycle.
|
|
Additional information:
|
|
reads or writes the count for the number of times a compact flash memory card
|
|
has been inserted in the device. This value is saved over a power cycle."
|
|
::= { settings-photo-job 23 }
|
|
|
|
|
|
photo-mmc-insert-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the count for the number of times a
|
|
MultiMediaCard memory card has been inserted in the device.
|
|
This value is saved over a power cycle.
|
|
Additional information:
|
|
reads or writes the count for the number of times a MultiMediaCard memory card
|
|
has been inserted in the device. This value is saved over a power cycle."
|
|
::= { settings-photo-job 24 }
|
|
|
|
|
|
photo-xd-insert-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reads or writes the count for the number of times an xD-Picture
|
|
memory card has been inserted in the device. This value is
|
|
saved over a power cycle.
|
|
Additional information:
|
|
reads or writes the count for the number of times an xD-Picture memory card
|
|
has been inserted in the device. This value is saved over a power cycle."
|
|
::= { settings-photo-job 25 }
|
|
|
|
|
|
hrstorageindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each logical storage area
|
|
contained by the host.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (mass storage) :
|
|
Constant. The index is assigned by the
|
|
person controlling the printer object definition.
|
|
The value of the hrFileSystemStorageIndex and the
|
|
index of the prtStorageRefIndex use the value of
|
|
this object's index. The value of the object
|
|
matches the value of the object's index. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a get on this OID with no mass storage device
|
|
installed. This first volume installed will be number 2,
|
|
followed by the second. IDE will always be 2. If ram disk
|
|
and flash disk are installed then Flash disk will be 2 followed
|
|
by ram disk. The Storage types are:
|
|
IDE (EIO DISK), Flash Disk, Ram Disk"
|
|
::= { hrStorageEntry 1 }
|
|
|
|
|
|
hrstoragetype OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of storage represented by this entry.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (mass storage):
|
|
Constant. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed.
|
|
HRMhrStorageFixedDisk is 1.3.6.1.2.1.25.2.1.4"
|
|
::= { hrStorageEntry 2 }
|
|
|
|
|
|
hrstoragedescr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of the type and instance of the
|
|
storage described by this entry.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (printer) :
|
|
This object is not localized.
|
|
Additional information (mass storage) :
|
|
This string indicates the location of the installed
|
|
mass storage device. The supported values are:
|
|
'Flash disk in DIMM slot 1'
|
|
'Flash disk in DIMM slot 2'
|
|
'Flash disk in DIMM slot 3'
|
|
'Disk in EIO 1'
|
|
'Disk in EIO 2'
|
|
'Disk in EIO 3'
|
|
'Static RAM disk using system memory'
|
|
Applications determine the location of the installed mass storage
|
|
device by getting this object. This string is not
|
|
localized. Returns <noSuchName>
|
|
status if attempting to perform a Get on this OID
|
|
with no mass storage device installed."
|
|
::= { hrStorageEntry 3 }
|
|
|
|
|
|
hrstorageallocationunits OBJECT-TYPE
|
|
SYNTAX INTEGER(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size, in bytes, of the data objects allocated
|
|
from this pool. If this entry is monitoring
|
|
sectors, blocks, buffers, or packets, for example,
|
|
this number will commonly be greater than one.
|
|
Otherwise this number will typically be one.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (printer) :
|
|
Unit is one byte.
|
|
Additional information (mass storage) :
|
|
Returns the value 1024 if the file system is
|
|
not initialized. Returns <noSuchName>
|
|
status if attempting to perform a Get on this OID
|
|
with no mass storage device installed."
|
|
::= { hrStorageEntry 4 }
|
|
|
|
|
|
hrstorageused OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of the storage represented by this
|
|
entry that is allocated, in units of
|
|
hrStorageAllocationUnits.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
This object returns the amount of memory in use
|
|
by the printer at the current time. This object should not be
|
|
used when creating a print
|
|
job for the device because the amount of memory in use will
|
|
likely be different when the printer processes the print job.
|
|
Additional information (mass storage) :
|
|
Applications can determine the amount of used
|
|
space on the installed mass storage device by getting the
|
|
hrStorageAllocationUnits object and this object. The amount
|
|
of used space is these two returned values multiplied
|
|
together. Returns the value 0 if the file system
|
|
is not initialized. Returns <noSuchName>
|
|
status if attempting to perform a Get on this OID
|
|
with no mass storage device installed."
|
|
::= { hrStorageEntry 6 }
|
|
|
|
|
|
hrstorageallocationfailures OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of requests for storage represented by
|
|
this entry that could not be honored due to not
|
|
enough storage. It should be noted that as this
|
|
object has a SYNTAX of Counter, that it does not
|
|
have a defined initial value. However, it is
|
|
recommended that this object be initialized to
|
|
zero.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (printer):
|
|
This object is set to zero at power on and when any
|
|
reset is done via prtGeneralReset.
|
|
This object is incremented whenever the printer is
|
|
short on memory (codewise: when PersMemoryCycle is
|
|
called with a parameter of 2).
|
|
Additional information (mass storage):
|
|
Total number of writes that failed
|
|
since power on) due to the mass storage device
|
|
being full. Returns the value 0 when the file
|
|
system has not been initialized. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrStorageEntry 7 }
|
|
|
|
|
|
hrdeviceindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each device contained by the
|
|
host. The value for each device must remain
|
|
constant at least from one re-initialization of the
|
|
agent to the next re-initialization.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (printer):
|
|
The entry in the Device Table which
|
|
describes the printer.
|
|
Additional information (mass storage):
|
|
Constant. The index is assigned by the
|
|
person controlling the printer object definition.
|
|
All device/mass storage/file system/partition
|
|
tables in Host Resources MIB and the Printer MIB that
|
|
relate to the mass storage device use the same index value.
|
|
The value of the index of the following objects is
|
|
this object's value:
|
|
prtDeviceRefIndex
|
|
hrDiskStorageIndex
|
|
hrPartitionIndex
|
|
hrFSIndex
|
|
The value of the object matches the value of the
|
|
object's index. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
|
|
::= { hrDeviceEntry 1 }
|
|
|
|
|
|
hrdevicetype OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of the type of device.
|
|
If this value is `hrDeviceProcessor { hrDeviceTypes
|
|
3 }' then an entry exists in the hrProcessorTable
|
|
which corresponds to this device.
|
|
If this value is `hrDeviceNetwork { hrDeviceTypes 4
|
|
}', then an entry exists in the hrNetworkTable
|
|
which corresponds to this device.
|
|
If this value is `hrDevicePrinter { hrDeviceTypes 5
|
|
}', then an entry exists in the hrPrinterTable
|
|
which corresponds to this device.
|
|
If this value is `hrDeviceDiskStorage {
|
|
hrDeviceTypes 6 }', then an entry exists in the
|
|
hrDiskStorageTable which corresponds to this
|
|
device.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (mass storage):
|
|
Constant. Applications should determine if
|
|
a mass storage device is installed by getting this object.
|
|
If the response is something other than HRMhrDeviceDiskStorage,
|
|
the application knows this row in the hrDeviceTable does not
|
|
refer to a mass storage object. Due to restrictions placed on
|
|
this object by the Host Resources Disk Table, the value of this
|
|
object must be HRMhrDeviceDiskStorge. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed. HRMhrDeviceDiskStorage is 1.3.6.1.2.1.25.3.1.6"
|
|
::= { hrDeviceEntry 2 }
|
|
|
|
|
|
hrdevicestatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHrunning(2),
|
|
eHwarning(3),
|
|
eHdown(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational state of the device
|
|
described by this row of the table. A value
|
|
unknown(1) indicates that the current state of the
|
|
device is unknown. running(2) indicates that the
|
|
device is up and running and that no unusual error
|
|
conditions are known. The warning(3) state
|
|
indicates that agent has been informed of an
|
|
unusual error condition by the operational software
|
|
(e.g., a disk device driver) but that the device is
|
|
still 'operational'. An example would be high
|
|
number of soft errors on a disk. A value of
|
|
testing(4), indicates that the device is not
|
|
available for use because it is in the testing
|
|
state. The state of down(5) is used only when the
|
|
agent has been informed that the device is not
|
|
available for any use.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (printer) :
|
|
The printer's condition is mapped as follows (printer):
|
|
|
|
eHrunning -- Printer ready to print or is printing. May be in power save
|
|
mode.
|
|
|
|
eHwarning -- A condition exists that needs attention but it is
|
|
not currently preventing printing. A non-critical alert is active.
|
|
|
|
eHdown -- Printer is not printing because it is offline or a critical
|
|
alert is active. Human interaction is needed to bring the printer to
|
|
a ready state.
|
|
Additional information (mass storage) :
|
|
Returns mass storage device status information.
|
|
running -- mass storage device functional. May be in power save
|
|
mode.
|
|
warning -- The mass storage device failed a self-test but completed
|
|
the power-on initialization sequence. The mass storage device
|
|
is readable even when the mass storage device fails the power-up
|
|
self-test in order to give the customer a chance to
|
|
retrieve any data that can be made available.
|
|
testing -- Mass storage device is executing a test.
|
|
down -- Mass storage device is non-functional. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrDeviceEntry 5 }
|
|
|
|
|
|
hrprinterstatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHother(1),
|
|
eHidle(3),
|
|
eHprinting(4),
|
|
eHwarmup(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of this printer device. When
|
|
in the idle(1), printing(2), or warmup(3) state,
|
|
the corresponding hrDeviceStatus should be
|
|
running(2) or warning(3). When in the unknown
|
|
state, the corresponding hrDeviceStatus should be
|
|
unknown(1).
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
The printer's condition is mapped as follows:
|
|
|
|
eHother -- The printer is offline or a critical alert is active.
|
|
|
|
eHidle -- The printer is not doing any of the items listed below
|
|
for eHprinting status.
|
|
|
|
eHprinting -- A job is currently being processed or printed or a PJL job
|
|
is being processed.
|
|
|
|
eHwarmup -- If hrDeviceStatus is eHdown, then the printer is currently
|
|
offline but is resolving the condition that caused it be offline.
|
|
If hrDeviceStatus is eHrunning, then the printer was in power save mode
|
|
and is now ready ready to print."
|
|
::= { hrPrinterEntry 1 }
|
|
|
|
|
|
hrprinterdetectederrorstate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents any error conditions
|
|
detected by the printer. The error conditions are
|
|
encoded as bits in an octet string, with the
|
|
following definitions:
|
|
Condition Bit # hrDeviceStatus
|
|
lowPaper 0 warning(3)
|
|
noPaper 1 down(5)
|
|
lowToner 2 warning(3)
|
|
noToner 3 down(5)
|
|
doorOpen 4 down(5)
|
|
jammed 5 down(5)
|
|
offline 6 down(5)
|
|
serviceRequested 7 warning(3)
|
|
If multiple conditions are currently detected and
|
|
the hrDeviceStatus would not otherwise be
|
|
unknown(1) or testing(4), the hrDeviceStatus shall
|
|
correspond to the worst state of those indicated,
|
|
where down(5) is worse than warning(3) which is
|
|
worse than running(2).
|
|
Bits are numbered starting with the most
|
|
significant bit of the first byte being bit 0, the
|
|
least significant bit of the first byte being bit
|
|
7, the most significant bit of the second byte
|
|
being bit 8, and so on. A one bit encodes that
|
|
the condition was detected, while a zero bit
|
|
encodes that the condition was not detected.
|
|
This object is useful for alerting an operator to
|
|
specific warning or error conditions that may
|
|
occur, especially those requiring human
|
|
intervention.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
LaserJet 4050 Series reports error conditions as follows:
|
|
|
|
lowPaper -- A tray is empty, but the media to be loaded is not
|
|
currently needed.
|
|
hrDeviceStatus = eHwarning;
|
|
hrPrinterStatus = eHidle or eHprinting;
|
|
A non-critical alert is active.
|
|
|
|
noPaper -- A tray is empty and must be filled for printing to continue.
|
|
hrDeviceStatus = eHdown;
|
|
hrPrinterStatus = eHother;
|
|
A critical alert is active.
|
|
|
|
lowToner -- Toner is almost gone. The quality of printed pages will begin
|
|
to deteriorate until the toner is completely gone.
|
|
hrDeviceStatus = eHwarning;
|
|
hrPrinterStatus = eHidle or eHprinting;
|
|
A non-critical alert is active.
|
|
|
|
noToner -- LaserJet 4050 Series printers do not report this condition.
|
|
|
|
coverOpen -- A printer cover or door is open.
|
|
hrDeviceStatus = eHdown;
|
|
hrPrinterStatus = eHother;
|
|
A critical alert is active.
|
|
|
|
jammed -- Paper is jammed and the printer will be unable to continue
|
|
printing until the jam is cleared.
|
|
hrDeviceStatus = eHdown;
|
|
hrPrinterStatus = eHother;
|
|
A critical alert is active.
|
|
|
|
offline -- Printer is offline and will not accept new print jobs until
|
|
it is online again.
|
|
hrDeviceStatus = eHdown;
|
|
hrPrinterStatus = eHother;
|
|
A critical alert is active.
|
|
|
|
serviceRequested -- Any status or error condition not listed
|
|
above. If the condition prevents printing, the 'offline'
|
|
bit is also set and the hrDeviceStatus and hrPrinterStatus listed for
|
|
offline above are returned.
|
|
hrDeviceStatus = eHwarning;
|
|
hrPrinterStatus = eHidle or eHprinting;
|
|
A non-critical alert is active."
|
|
::= { hrPrinterEntry 2 }
|
|
|
|
|
|
prtgeneralconfigchanges OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483648)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Counts configuration changes that change the capabilities of
|
|
a printer, such as the addition/deletion of input/output bins,
|
|
the addition/deletion of interpreters, or changes in media
|
|
size. Such changes will often affect the capability of the
|
|
printer to service certain types of print jobs.
|
|
Management applications may cache infrequently changed
|
|
configuration information about sub-units on the printer.
|
|
This object should be incremented whenever the agent wishes
|
|
such applications to invalidate that cache and re-download
|
|
all of this configuration information, thereby signaling a
|
|
change in the printer's configuration.
|
|
|
|
For example, if an input tray that contained paper of
|
|
different dimensions was added, this counter would be
|
|
incremented.
|
|
As an additional example, this counter would not be
|
|
incremented when an input tray is removed or the level of an
|
|
input device changes.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This is a 32 bit counter (unsigned). When it reaches
|
|
its maximum value, it will roll to zero."
|
|
::= { prtGeneralEntry 1 }
|
|
|
|
|
|
prtgeneralcurrentlocalization OBJECT-TYPE
|
|
SYNTAX INTEGER(1..17)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the prtLocalizationIndex corresponding to the
|
|
current language, country, and character set to be used for
|
|
localized string values that are identified as being dependent
|
|
on the value of this object. Note that this object does not
|
|
apply to localized strings in the prtConsole group or to any
|
|
object that is not explicitly identified as being localized
|
|
according to prtGeneralCurrentLocalization.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The value of this object is saved in NVRAM."
|
|
::= { prtGeneralEntry 2 }
|
|
|
|
|
|
prtgeneralreset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePnotResetting(3),
|
|
ePpowerCycleReset(4),
|
|
ePresetToNVRAM(5),
|
|
ePresetToFactoryDefaults(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this value to `powerCycleReset', `resetToNVRAM', or
|
|
`resetToFactoryDefaults' will result in the resetting of the
|
|
printer. When read, this object will always have the value
|
|
`notResetting(3)', and a SET of the value `notResetting' shall
|
|
have no effect on the printer. Some of the defined values are
|
|
optional. However, every implementation must support at least
|
|
the values `notResetting' and 'resetToNVRAM'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML USER-NVRAM-RESET and POWER-ON-RESET.
|
|
|
|
The, the following sequence of events occur when this object is set to
|
|
ePpowerCycleReset, ePresetToNVRAM, or ePresetToFactoryDefaults:
|
|
1. Wait until a job boundary.
|
|
2. The paper path is flushed.
|
|
3. The printer is reset per the request. The printer will respond to PML
|
|
requests up to this point in time.
|
|
|
|
All settings will make the printer go thru its power-on initialization
|
|
routines and I/O cards are reset.
|
|
|
|
When this object is set to ePpowerCycleReset or ePresetToNVRAM, the printer
|
|
performs its power on initialization routines. I/O cards are reset, although
|
|
NVRAM on the cards is not changed, and all I/O buffers are flushed. This is
|
|
equivalent to turning the printer off and then on again.
|
|
|
|
Setting this object to ePresetToFactoryDefaults causes the same action as
|
|
ePpowerCycleReset exept that it also changes all configurable settings back
|
|
to their factory defaults. It is equivalent to doing a Cold Reset from the
|
|
control panel while turning on the printer."
|
|
::= { prtGeneralEntry 3 }
|
|
|
|
|
|
prtgeneralcurrentoperator OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the person who is responsible for operating
|
|
this printer. It is suggested that this string include
|
|
information that would enable other humans to reach the operator,
|
|
such as a phone number. As a convention to facilitate automatic
|
|
notification of the operator by the agent or the network
|
|
management station, the phone number, fax number or email address
|
|
should be placed on a separate line starting with ASCII LF (hex
|
|
0x0A) and the ASCII text string (without the quotes): 'phone: ',
|
|
'fax: ', and 'email: ', respectively. Phone numbers may contain
|
|
digits, whitespace and parentheses, which shall be ignored. Phone
|
|
numbers may also include ASCII comma characters(hex 2C) that are
|
|
used to indicate a two-second pause during the dialing sequence.
|
|
If either the phone, fax, or email information is not available,
|
|
then a line should not be included for this information.
|
|
NOTE: For interoperability purposes, it is advisable to use email
|
|
addresses formatted according to RFC 822 requirements.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML SYSTEM-CONTACT.
|
|
The maximum supported string length is 32 characters.
|
|
Length of 32 was chosen so a phone number could be
|
|
included with the name.
|
|
If the user entered string is too long, the device
|
|
will store as much as possible and will return the
|
|
<noError> status."
|
|
::= { prtGeneralEntry 4 }
|
|
|
|
|
|
prtgeneralserviceperson OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the person responsible for servicing this
|
|
printer. It is suggested that this string include information
|
|
that would enable other humans to reach the service person, such
|
|
as a phone number. As a convention to facilitate automatic
|
|
notification of the service person by the agent or a network
|
|
management station, the phone number, fax number or email address
|
|
should be placed on a separate line starting with ASCII LF (hex
|
|
0x0A) and the ASCII text string (without the quotes): 'phone: ',
|
|
'fax: ', and 'email: ', respectively. Phone numbers may contain
|
|
digits, whitespace and parentheses, which shall be ignored. Phone
|
|
numbers can also include one or more ASCII comma characters(hex
|
|
2C) to indicate a two-second pause during the dialing sequence.
|
|
If either the phone,fax, or email information is not available,
|
|
then a line should not included for this information.
|
|
NOTE: For interoperability purposes, it is advisable to use email
|
|
addresses formatted according to RFC 822 requirements.
|
|
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML SYSTEM-CONTACT.
|
|
The maximum supported string length is 32 characters.
|
|
Length of 32 was chosen so a phone number could be
|
|
included with the name.
|
|
If the user entered string is too long, the device
|
|
will store as much as possible and will return the
|
|
<noError> status."
|
|
::= { prtGeneralEntry 5 }
|
|
|
|
|
|
prtconsolelocalization OBJECT-TYPE
|
|
SYNTAX INTEGER(1..17)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the prtLocalizationIndex corresponding to
|
|
the language, country, and character set to be used for the
|
|
console. This localization applies both to the actual display
|
|
on the console as well as the encoding of these console
|
|
objects in management operations.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The value of this object is saved in NVRAM.
|
|
If a localized string is currently being displayed on the control panel by the
|
|
device, changing this object will cause the displayed string to be changed
|
|
to its new value. If this object is changed while the printer is processing
|
|
a page that contains localized strings, the results are undefined."
|
|
::= { prtGeneralEntry 10 }
|
|
|
|
|
|
prtconsolenumberofdisplaylines OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of lines on the printer's physical
|
|
display. This value is 0 if there are no lines on the
|
|
physical display or if there is no physical display
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The printer has two physical lines on the display,
|
|
however, in many cases up to four seperate lines
|
|
of text may be displayed by alternating pairs of
|
|
lines every three seconds. Thus the display really
|
|
has four logical lines for displaying messages.
|
|
This object will return the number of logical
|
|
display lines supported by the printer."
|
|
::= { prtGeneralEntry 11 }
|
|
|
|
|
|
prtconsolenumberofdisplaychars OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of characters per line displayed on the physical
|
|
display. This value is 0 if there are no lines on the
|
|
physical display or if there is no physical display
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtGeneralEntry 12 }
|
|
|
|
|
|
prtconsoledisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePoperatorConsoleEnabled(3),
|
|
ePoperatorConsoleDisabled(4),
|
|
ePoperatorConsoleEnabledLevel1(5),
|
|
ePoperatorConsoleEnabledLevel2(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the object prtConsoleDisable has value
|
|
'operatorConsoleDisabled' then input is not accepted from the
|
|
operator console. If the object prtConsoleDisable has the value
|
|
'operatorConsoleEnabled' then input is accepted from the
|
|
operator console. If the object prtConsoleDisable has the value
|
|
'operatorConsoleEnabledLevel1','operatorConsoleEnabledLevel2' or
|
|
'operatorConsoleEnabledLevel3' then limited input is accepted
|
|
from the operator console; the limitations are product specific,
|
|
however, the limitations are generally less restrictive for
|
|
operatorConsoleEnabledLevel1 than for
|
|
operatorConsoleEnabledLeve2, which is less restrictive than
|
|
operatorConsoleEnabledLevel3.
|
|
The value of the prtConsoleDisable object is a type-2
|
|
enumeration.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
If the object prtConsoleDisable has value
|
|
'ePoperatorConsoleDisabled' then manual input is not
|
|
accepted from the operator console. If the object prtConsoleDisable has the
|
|
value 'ePoperatorConsoleEnabled' then manual input is accepted from the
|
|
operator console.
|
|
The following menus are locked with these corresponding
|
|
values:
|
|
ePoperatorConsoleEnabled (no locking)
|
|
ePoperatorConsoleEnabledLevel1 (minimal locking)
|
|
RESETS MENU
|
|
CONFIGURATION MENU
|
|
I/O MENU
|
|
ePoperatorConsoleEnabledLevel2 (moderate locking)
|
|
PRINT QUALITY MENU
|
|
PAPER HANDLING MENU
|
|
menus in level 1
|
|
ePoperatorConsoleDisabled (maximum locking)
|
|
PRINTING MENU
|
|
INFORMATION MENU
|
|
Job Cancel
|
|
menus in levels 1 and 2"
|
|
::= { prtGeneralEntry 13 }
|
|
|
|
|
|
prtgeneralstartuppage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePnotPresent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to enable or disable printing a startup page. If
|
|
enabled, a startup page will be printed shortly after
|
|
power-up, when the device is ready. Typical startup
|
|
pages include test patterns and/or printer configuration
|
|
information.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtGeneralEntry 14 }
|
|
|
|
|
|
prtgeneralbannerpage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePnotPresent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to enable or disable printing banner pages at the
|
|
beginning of jobs. This is a master switch which applies
|
|
to all jobs, regardless of interpreter.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtGeneralEntry 15 }
|
|
|
|
|
|
prtgeneralprintername OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An administrator-specified name for this printer.
|
|
Depending upon implementation of this printer, the value of this
|
|
object may or may not be same as the value for the MIB-II
|
|
'SysName' object.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The maximum supported string length is 32 characters.
|
|
Length of 32 was chosen so a phone number could be
|
|
included with the name.
|
|
If the user-entered string is too long, the device
|
|
will store as much as possible and will return the
|
|
<noError> status.
|
|
The value of this object is saved over a power cycle."
|
|
::= { prtGeneralEntry 16 }
|
|
|
|
|
|
prtgeneralserialnumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A recorded serial number for this device that indexes some type
|
|
device catalog or inventory. This value is usually set by the
|
|
device manufacturer but the MIB supports the option of
|
|
writeability for this object for site-specific administration of
|
|
device inventory or tracking.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtGeneralEntry 17 }
|
|
|
|
|
|
prtalertcriticalevents OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A running counter of the number of critical alert events
|
|
that have been recorded in the alert table. The value of this
|
|
object is RESET in the event of a power cycle operation (i.e.,
|
|
the value is not persistent.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object is set to zero every time the printer is
|
|
turned on."
|
|
::= { prtGeneralEntry 18 }
|
|
|
|
|
|
prtalertallevents OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A running counter of the total number of alert event entries
|
|
(critical and non-critical) that have been recorded in the
|
|
alert table
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object is set to zero every time the printer is
|
|
turned on. (It is not persistent through a power-cycle.)"
|
|
::= { prtGeneralEntry 19 }
|
|
|
|
|
|
prtlocalizationlanguage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..2))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A two character language code from ISO 639. Examples
|
|
en, gb, ca, fr, de.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The languages supported by LaserJet 4050 Series are English, French,
|
|
German, Italian, Spanish, Swedish, Danish, Norwegian, Dutch, Finnish,
|
|
Portuguese, Turkish, Polish, Japanese, Russian, Czech, and Hungarian."
|
|
::= { prtLocalizationEntry 2 }
|
|
|
|
|
|
prtlocalizationcountry OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..2))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A two character country code from ISO 3166, a blank string
|
|
(two space characters) shall indicate that the country is
|
|
not defined. Examples: US, FR, DE, ...
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The languages supported by LaserJet 4050 Series (and corresponding
|
|
country) are English (US, United States), French (FR, France),
|
|
German (DE, Germany), Italian (IT, Italy), Spanish (ES, Spain),
|
|
Swedish (SE, Sweden), Danish (DK, Denmark), Norwegian (NO, Norway),
|
|
Dutch (NL, Netherlands), Finnish (FI, Finland), Portuguese (PT, Portugal),
|
|
Turkish (TR, Turkey), Polish (PL, Poland), Japanese (JP, Japan),
|
|
Russian, (RU, Russia), Czech (CS, Czechoslovakia),
|
|
Hungarian (HU, Hungary)"
|
|
::= { prtLocalizationEntry 3 }
|
|
|
|
|
|
prtlocalizationcharacterset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePcsHPRoman8(2004),
|
|
ePcsISOLatin2(5),
|
|
ePcsISOLatin5(12),
|
|
ePcsWindows31J(2024),
|
|
ePcsISOLatinCyrillic(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The coded character set used for this localization.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtLocalizationEntry 4 }
|
|
|
|
|
|
prtstoragerefindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the hrDeviceIndex of the printer device that this
|
|
storageEntry is associated with.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information (mass storage):
|
|
Constant. The index value indicates
|
|
the hrStorageTable index for this storage device.
|
|
The value indicates the hrDeviceTable index for the
|
|
printer which uses this storage device. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no storage device
|
|
is installed."
|
|
::= { prtStorageRefEntry 2 }
|
|
|
|
|
|
prtdevicerefindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the hrDeviceIndex of the printer device that this
|
|
deviceEntry is associated with.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information (mass storage) :
|
|
Constant. The index indicates the
|
|
hrDeviceIndex for this mass storage device. The value indicates
|
|
the hrDeviceIndex for the printer which uses this
|
|
mass storage device. Returns <noSuchName> status
|
|
if attempting to perform a Get on this OID with no
|
|
mass storage device installed."
|
|
|
|
::= { prtDeviceRefEntry 2 }
|
|
|
|
|
|
prtmarkeraddressabilityfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of addressable marking positions in the feed
|
|
direction per 10000 units of measure specified by
|
|
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
|
|
'infinite' while a value of (-2) implies 'unknown'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object indicates the value of the resolution
|
|
(dots per inch) setting for the printer. LaserJet 5000 Series
|
|
and LaserJet 4000 Series support 300, 600 and 1200 dots per inch. LaserJet 8100 Series
|
|
and LaserJet 8000 Series supports 300 or 600 dots per inch. 600 dots per inch is
|
|
the default."
|
|
::= { prtMarkerEntry 9 }
|
|
|
|
|
|
prtmarkeraddressabilityxfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of addressable marking positions in the cross
|
|
feed direction in 10000 units of measure specified by
|
|
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
|
|
'infinite' while a value of (-2) implies 'unknown'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object indicates the value of the resolution
|
|
(dots per inch) setting for the printer. LaserJet 5000 Series
|
|
and LaserJet 4000 Series support 300, 600 and 1200 dots per inch. LaserJet 8100 Series
|
|
and LaserJet 8000 Series supports 300 or 600 dots per inch. 600 dots per inch is
|
|
the default."
|
|
::= { prtMarkerEntry 10 }
|
|
|
|
|
|
prtconsoledisplaybuffertext OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The content of a line in the logical display buffer of
|
|
the operator's console of the printer. When a write
|
|
operation occurs, normally a critical message, to one of
|
|
the LineText strings, the agent should make that line
|
|
displayable if a physical display is present. Writing
|
|
a zero length string clears the line. It is an
|
|
implementation-specific matter as to whether the agent allows
|
|
a line to be overwritten before it has been cleared.
|
|
Printer generated strings shall be in the localization
|
|
specified by prtConsoleLocalization. Management Application
|
|
generated strings should be localized by the Management
|
|
Application.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML STATUS-MSG-LINE1-PART1 and
|
|
STATUS-MSG-LINE2-PART1 (read functionality).
|
|
The proprietary objects BACKGROUND-STATUS-MSG-LINE1-PART1
|
|
and BACKGROUND-STATUS-MSG-LINE2-PART1 should be used to
|
|
write messages to the control panel display.
|
|
|
|
prtConsoleDisplayBufferText.1.[1..6] maps to logical lines
|
|
1-6 of the display.
|
|
|
|
Most of the time the display will show a single one or two line
|
|
message. This message can be retrieved by reading
|
|
prtConsoleDisplayBufferText.1.1 and
|
|
prtConsoleDisplayBufferText.1.2. In this case
|
|
prtConsoleDisplayBufferText.1.[3..6] will be NULL.
|
|
|
|
If prtConsoleDisplayBufferText.1.3 or
|
|
prtConsoleDisplayBufferText.1.4 is not NULL, the display will
|
|
be alternating.
|
|
|
|
If prtConsoleDisplayBufferText.1.[5..6] are NULL, the display
|
|
will alternate prtConsoleDisplayBufferText.1.[1..2] with
|
|
prtConsoleDisplayBufferText.1.[3..4].
|
|
|
|
If prtConsoleDisplayBufferText.1.5 or
|
|
prtConsoleDisplayBufferText.1.6 is not NULL, the display will
|
|
show prtConsoleDisplayBufferText.1.[1..2] then
|
|
prtConsoleDisplayBufferText.1.[3..4] then
|
|
prtConsoleDisplayBufferText.1.[5..6].
|
|
|
|
The display will alternate between line pairs at three second
|
|
intervals. "
|
|
::= { prtConsoleDisplayBufferEntry 2 }
|
|
|
|
|
|
prtconsoleontime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, in conjunction with prtConsoleOffTime, defines
|
|
the current status of the light. If both prtConsoleOnTime and
|
|
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
|
values presented define the on time and off time, respectively,
|
|
in milliseconds. If prtConsoleOnTime is zero and
|
|
prtConsoleOffTime is non-zero, the lamp is off. If
|
|
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
|
|
the lamp is on. If both values are zero the status of the
|
|
lamp is undefined.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
There are three control panel LED's: Ready (1),
|
|
Data (2), and Attention (3). When an LED blinks, it is typically on for
|
|
one half second and off for one half second. The value used for this object
|
|
is 500 when the LED is on or blinking, otherwise it is zero."
|
|
::= { prtConsoleLightEntry 2 }
|
|
|
|
|
|
prtconsoleofftime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object, in conjunction with prtConsoleOnTime, defines
|
|
the current status of the light. If both prtConsoleOnTime and
|
|
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
|
values presented define the on time and off time, respectively,
|
|
in milliseconds. If prtConsoleOnTime is zero and
|
|
prtConsoleOffTime is non-zero, the lamp is off. If
|
|
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
|
|
the lamp is on. If both values are zero the status of the
|
|
lamp is undefined.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
There are three control panel LED's: Ready (1),
|
|
Data (2), and Attention (3). When an LED blinks, it is typically on for
|
|
one half second and off for one half second. The value used for this object
|
|
is 500 when the LED is off or blinking, otherwise it is zero."
|
|
::= { prtConsoleLightEntry 3 }
|
|
|
|
|
|
prtconsoledescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vendor description or label of this light in the
|
|
localization specified by prtConsoleLocalization.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtConsoleLightEntry 5 }
|
|
|
|
|
|
prtalertseveritylevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePcriticalBinaryChangeEvent(3),
|
|
ePwarningUnaryChangeEvent(4),
|
|
ePwarningBinaryChangeEvent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The level of severity of this alert table entry. The printer
|
|
determines the severity level assigned to each entry into the
|
|
table.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtAlertEntry 2 }
|
|
|
|
|
|
prtalerttraininglevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePuntrained(3),
|
|
ePtrained(4),
|
|
ePfieldService(5),
|
|
ePmanagement(6),
|
|
ePnoInterventionRequired(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"See textual convention PrtAlertTrainingLevelTC
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The value of this object depends on the alert.
|
|
Some examples:
|
|
ePfieldService: Marker failure.
|
|
ePtrained: Toner low.
|
|
ePuntrained: Paper low/out.
|
|
ePmanagement: Configuration change."
|
|
::= { prtAlertEntry 3 }
|
|
|
|
|
|
prtalertgroup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePgeneralPrinter(5),
|
|
ePcover(6),
|
|
ePinput(8),
|
|
ePoutput(9),
|
|
ePmarker(10),
|
|
ePmarkerSupplies(11),
|
|
ePchannel(14)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of sub-unit within the printer model that this alert
|
|
is related. Input, output, and markers are examples of
|
|
printer model groups, i.e., examples of types of sub-units.
|
|
Wherever possible, these enumerations match the
|
|
sub-identifier that identifies the relevant table in the
|
|
printmib.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtAlertEntry 4 }
|
|
|
|
|
|
prtalertgroupindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index of the row within the principle table in the
|
|
group identified by prtAlertGroup that represents the
|
|
sub-unit of the printer that caused this alert. The
|
|
combination of the prtAlertGroup and the prtAlertGroupIndex defines
|
|
exactly which printer sub-unit caused the alert.; for
|
|
example, Input #3, Output #2, and Marker #1.
|
|
Every object in this MIB is indexed with hrDeviceIndex and
|
|
optionally, another index variable. If this other index
|
|
variable is present in the table that generated the alert, it
|
|
will be used as the value for this object. Otherwise, this
|
|
value shall be -1.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtAlertEntry 5 }
|
|
|
|
|
|
prtalertlocation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sub-unit location that is defined by the printer
|
|
manufacturer to further refine the location of this alert
|
|
within the designated sub-unit. The location is used in
|
|
conjunction with the Group and GroupIndex values; for
|
|
example, there is an alert in Input #2 at location number 7.
|
|
The value (-2) indicates unknown
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtAlertEntry 6 }
|
|
|
|
|
|
prtalertcode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePcoverOpened(3),
|
|
ePjam(8),
|
|
ePsubunitMissing(9),
|
|
ePsubunitAlmostEmpty(12),
|
|
ePsubunitEmpty(13),
|
|
ePsubunitAlmostFull(14),
|
|
ePsubunitFull(15),
|
|
ePsubunitOffline(22),
|
|
ePsubunitPowerSaver(23),
|
|
ePsubunitMotorFailure(33),
|
|
ePsubunitMemoryExhausted(34),
|
|
ePmarkerFuserUnderTemperature(1001),
|
|
ePmarkerFuserOverTemperature(1002),
|
|
ePmarkerTonerEmpty(1101),
|
|
ePmarkerTonerAlmostEmpty(1104)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"See associated textual convention PrtAlertCodeTC
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtAlertEntry 7 }
|
|
|
|
|
|
prtalertdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of this alert entry in the localization
|
|
specified by prtGeneralCurrentLocalization. The description is
|
|
provided by the printer to further elaborate on the enumerated
|
|
alert or provide information in the case where the code is
|
|
classified as `other' or `unknown'. The printer is required
|
|
to return a description string but the string may be a null
|
|
string.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtAlertEntry 8 }
|
|
|
|
|
|
prtalerttime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time that this alert was
|
|
generated.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtAlertEntry 9 }
|
|
|
|
|
|
job-input-auto-continue-timeout OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..3600)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds the device waits after a job
|
|
related continuable error occurs before automatically
|
|
continuing. An example job related continuable error is
|
|
the job requesting a media size that is not available.
|
|
After the timeout expires, the device will continue
|
|
processing the job as if a continue event occurred, such
|
|
as the front panel continue key being pressed. If the
|
|
value is -1, the device does not automatically continue
|
|
after a job related continuable error occurs. If the
|
|
value is 0, the device immediately continues. If the
|
|
value is greater than 0, the value represents the
|
|
timeout value in seconds.
|
|
Additional information:
|
|
This object is used only for media requests
|
|
(size and/or name). LaserJet 4050 Series supports any value in
|
|
the range of -1 to 3600. Setting to a value outside
|
|
of that range causes the printer to substitute a
|
|
value (listed below) and to return
|
|
<noError> status. The
|
|
values are as follow: <-1 snaps to -1
|
|
>3600 snaps to 3600 (60 minutes) The action that
|
|
occurs when this timeout expires is explained by
|
|
JOB-INPUT-AUTO-CONTINUE-MODE. It is not the same as
|
|
the CONTINUE object being set to eInitiateAction or
|
|
the Select key being pressed on the control panel.
|
|
See the CONTINUE object description for
|
|
information on the actions that occur for those
|
|
conditions.
|
|
The data for this object is stored in NVRAM."
|
|
::= { status-system 35 }
|
|
|
|
|
|
job-input-auto-continue-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when the desired
|
|
media is not currently available.
|
|
cCancelJob - The device cancels the job. The device
|
|
POS should explain what happens if this item is not the
|
|
only item in the collection.
|
|
cAutoMediaSizeOverride - The device is allowed to
|
|
substitute a different size media.
|
|
cAutoMediaNameOverride - The device is allowed to
|
|
substitute a different media name.
|
|
Additional information:
|
|
If cCancelJob is set, the current print job will
|
|
be canceled regardless of other item settings. At
|
|
least one bit of the collection must be set; setting
|
|
this object to zero will cause a status of
|
|
<badValue> to be returned.
|
|
This object applies to all media requests, including
|
|
Manual Feed Requests. This object describes the
|
|
action that is performed when the
|
|
JOB-INPUT-AUTO-CONTINUE-TIMEOUT expires. The action
|
|
performed by the CONTINUE object being set to
|
|
eInitiateAction or the GO key being pressed on the
|
|
control panel may cause different actions. See the
|
|
CONTINUE object description for information on the
|
|
actions that occur for those conditions.
|
|
The data for this object is stored in NVRAM."
|
|
::= { status-system 36 }
|
|
|
|
|
|
job-output-auto-continue-timeout OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..3600)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the time that the printer will wait
|
|
after an output bin becomes full and the printer is
|
|
trying to deliver a sheet of media to that output bin.
|
|
When the timeout expires, the job is processed according
|
|
to the OUTBINn-OVERRIDE-MODE. A value of -1 indicates
|
|
that the printer will wait for a continue event. A non-
|
|
negative value is the number of seconds to wait.
|
|
Additional information:
|
|
A value of zero means to continue immediately.
|
|
The value of this object is stored in NVRAM, so
|
|
it is maintained across a power cycle.
|
|
The data for this object is stored in NVRAM."
|
|
::= { status-system 40 }
|
|
|
|
|
|
phd2-model OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying PHD device 2.
|
|
Additional information:
|
|
If at least one (1) external paper handling device
|
|
is attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns product information about the
|
|
first paper handling device in the device chain."
|
|
::= { phd2 1 }
|
|
|
|
|
|
phd2-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of PHD 2.
|
|
May include serial number and firmware revision.
|
|
Additional information:
|
|
If at least one (1) external paper handling device
|
|
is attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the name of the manufacturer of
|
|
the first paper handling device."
|
|
::= { phd2 2 }
|
|
|
|
|
|
phd2-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUnknown(2),
|
|
eInputPHD(10),
|
|
eOutputPHD(11),
|
|
eBindingPHD(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
PHD interface 2. See SIMM1-TYPE for an explanation of
|
|
the enumerations.
|
|
Additional information:
|
|
If at least one (1) external paper handling device
|
|
is attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns whether the device is an input
|
|
device, an output device, or an unknown device which may
|
|
be developed in the future."
|
|
::= { phd2 3 }
|
|
|
|
|
|
phd2-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the installed
|
|
option. See SIMM1-CAPACITY for an explanation of the
|
|
meaning of the value of this object.
|
|
Additional information:
|
|
If at least one (1) external paper handling device
|
|
(EPHD) is attached to the printer, then this object
|
|
will exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the number of input trays or
|
|
output bins, depending the the device type (see
|
|
PHD2-TYPE) for the first EPHD in the device chain."
|
|
::= { phd2 4 }
|
|
|
|
|
|
phd3-model OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying PHD device 3.
|
|
Additional information:
|
|
If at least two (2) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns product information about the
|
|
second paper handling device in the device chain."
|
|
::= { phd3 1 }
|
|
|
|
|
|
phd3-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of PHD 3.
|
|
May include serial number and firmware revision.
|
|
Additional information:
|
|
If at least two (2) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the name of the manufacturer of
|
|
the second paper handling device."
|
|
::= { phd3 2 }
|
|
|
|
|
|
phd3-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUnknown(2),
|
|
eInputPHD(10),
|
|
eOutputPHD(11),
|
|
eBindingPHD(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
PHD interface 3. See SIMM1-TYPE for an explanation of
|
|
the enumerations.
|
|
Additional information:
|
|
If at least two (2) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns whether the second device is an
|
|
input device, an output device, or an unknown object which may
|
|
be developed in the future."
|
|
::= { phd3 3 }
|
|
|
|
|
|
phd3-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the installed
|
|
option. See SIMM1-CAPACITY for an explanation of the
|
|
meaning of the value of this object.
|
|
Additional information:
|
|
If at least two (2) external paper handling devices
|
|
(EPHD) are attached to the printer, then this object
|
|
will exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the number of input trays or
|
|
output bins, depending the the device type (see
|
|
PHD3-TYPE) for the second EPHD in the device chain."
|
|
::= { phd3 4 }
|
|
|
|
|
|
phd4-model OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying PHD device 4.
|
|
Additional information:
|
|
If at least three (3) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns product information about the
|
|
third paper handling device in the device chain."
|
|
::= { phd4 1 }
|
|
|
|
|
|
phd4-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of PHD 4.
|
|
May include serial number and firmware revision.
|
|
Additional information:
|
|
If at least three (3) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the name of the manufacturer of
|
|
the third paper handling device."
|
|
::= { phd4 2 }
|
|
|
|
|
|
phd4-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUnknown(2),
|
|
eInputPHD(10),
|
|
eOutputPHD(11),
|
|
eBindingPHD(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
PHD interface 4. See SIMM1-TYPE for an explanation of
|
|
the enumerations.
|
|
Additional information:
|
|
If at least three (3) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns whether the third device is an
|
|
input device, an output device, or an unknown device which may
|
|
be developed in the future."
|
|
::= { phd4 3 }
|
|
|
|
|
|
phd4-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the installed
|
|
option. See SIMM1-CAPACITY for an explanation of the
|
|
meaning of the value of this object.
|
|
Additional information:
|
|
If at least three (3) external paper handling devices
|
|
(EPHD) are attached to the printer, then this object
|
|
will exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the number of input trays or
|
|
output bins, depending the the device type (see
|
|
PHD4-TYPE) for the third EPHD in the device chain."
|
|
::= { phd4 4 }
|
|
|
|
|
|
phd5-model OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying PHD device 3.
|
|
Additional information:
|
|
If at least four (4) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns product information about the
|
|
fourth paper handling device in the device chain."
|
|
::= { phd5 1 }
|
|
|
|
|
|
phd5-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of PHD 5.
|
|
May include serial number and firmware revision.
|
|
Additional information:
|
|
If at least four (4) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the name of the manufacturer of
|
|
the fourth paper handling device."
|
|
::= { phd5 2 }
|
|
|
|
|
|
phd5-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUnknown(2),
|
|
eInputPHD(10),
|
|
eOutputPHD(11),
|
|
eBindingPHD(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
PHD interface 5. See SIMM1-TYPE for an explanation of
|
|
the enumerations.
|
|
Additional information:
|
|
If at least four (4) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns whether the fourth device is an
|
|
input device, an output device, or an unknown device which may
|
|
be developed in the future."
|
|
::= { phd5 3 }
|
|
|
|
|
|
phd5-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the installed
|
|
option. See SIMM1-CAPACITY for an explanation of the
|
|
meaning of the value of this object.
|
|
Additional information:
|
|
If at least four (4) external paper handling devices
|
|
(EPHD) are attached to the printer, then this object
|
|
will exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the number of input trays or
|
|
output bins, depending the the device type (see
|
|
PHD5-TYPE) for the fourth EPHD in the device chain."
|
|
::= { phd5 4 }
|
|
|
|
|
|
phd6-model OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying PHD device 6.
|
|
Additional information:
|
|
If at least five (5) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns product information about the
|
|
fifth paper handling device in the device chain."
|
|
::= { phd6 1 }
|
|
|
|
|
|
phd6-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of PHD 6.
|
|
May include serial number and firmware revision.
|
|
Additional information:
|
|
If at least five (5) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the name of the manufacturer of
|
|
the fifth paper handling device."
|
|
::= { phd6 2 }
|
|
|
|
|
|
phd6-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUnknown(2),
|
|
eInputPHD(10),
|
|
eOutputPHD(11),
|
|
eBindingPHD(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
PHD interface 6. See SIMM1-TYPE for an explanation of
|
|
the enumerations.
|
|
Additional information:
|
|
If at least five (5) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns whether the fifth device is an
|
|
input device, an output device, or an unknown device which may
|
|
be developed in the future."
|
|
::= { phd6 3 }
|
|
|
|
|
|
phd6-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the installed
|
|
option. See SIMM1-CAPACITY for an explanation of the
|
|
meaning of the value of this object.
|
|
Additional information:
|
|
If at least five (5) external paper handling devices
|
|
(EPHD) are attached to the printer, then this object
|
|
will exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the number of input trays or
|
|
output bins, depending the the device type (see
|
|
PHD6-TYPE) for the fifth EPHD in the device chain."
|
|
::= { phd6 4 }
|
|
|
|
|
|
tray1-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this input tray.
|
|
Additional information:
|
|
The internal trays belong to device 0, which is the
|
|
base engine. The envelope feeder (if supported) is
|
|
considered to be device 1 and the external input devices
|
|
can number between 2 and 6 depending on individual
|
|
user configurations."
|
|
::= { intray1 12 }
|
|
|
|
tray1-fuser-temperature OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fuser temperature to be used when printing media
|
|
from Tray 1. The value zero is the default temperature.
|
|
Values less than zero are progressively lower and values
|
|
greater than zero are progressively higher. The range
|
|
of values supported is device specific.
|
|
Additional information:
|
|
HP LaserJet 2100 Series supports 3 fuser temperatures.
|
|
Zero (0) is the default temperature, one(1) is a higher
|
|
temperature (for use on media like cardstock), negative
|
|
one (-1) is a lower temperature (for use on media like
|
|
transparencies).
|
|
|
|
Setting to an unsupported value causes the printer to
|
|
snap to the nearest supported value and to return
|
|
<noError> status along with
|
|
the actual value that was written.
|
|
|
|
The snap values are as follows:
|
|
<=-1 snaps to -1
|
|
>=1 snaps to 1"
|
|
::= { intray1 13 }
|
|
|
|
overflow-bin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the bin that will be used for additional
|
|
sheets of media when the current bin is full and
|
|
printing is allowed to continue.
|
|
Additional information:
|
|
The data for this object is stored in NVRAM."
|
|
::= { settings-outbin 4 }
|
|
|
|
|
|
outbin1-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
If cCancelJob is set, the current print job will
|
|
be cancelled regardless of other item settings.
|
|
If cOutbinFullOverride is set and this bin is the
|
|
designated overflow bin (OVERFLOW-BIN = 1), then the
|
|
bit is ignored. This object describes the action
|
|
that is performed when the
|
|
JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires. If no bits
|
|
are set, no override action is taken (the printer
|
|
will continue to wait).
|
|
The action performed by the CONTINUE object being set
|
|
to eInitiateAction or the GO key being pressed on the
|
|
control panel may cause different actions. See the
|
|
CONTINUE object
|
|
description for information on the actions that occur
|
|
for those conditions."
|
|
::= { outbin1 9 }
|
|
|
|
outbin1-maximum-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum capacity of the output bin, in sheets of 20
|
|
pound paper."
|
|
::= { outbin1 1 }
|
|
|
|
outbin2-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN1-OVERRIDE-MODE."
|
|
::= { outbin2 9 }
|
|
|
|
phd2-device-specific-command OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to send device-specific data to the
|
|
paper handling device. The meaning of the device-
|
|
specific command is dependent on the paper handling
|
|
device and must be specified in the POS.
|
|
If the paper handling device does not accept the
|
|
command, then an <badValue> will
|
|
be returned. If the device accepts the command, it may
|
|
still be processing the command after the response has
|
|
been returned. Depending on the device, the application
|
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
|
command has completed.
|
|
Additional information:
|
|
If at least one (1) external paper handling device
|
|
is attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
will be returned.
|
|
Since the data formats can vary from device to
|
|
device, this information must be documented for
|
|
each device by the manufacturer of the device.
|
|
If the device does not support this command, then
|
|
an <badValue> error message
|
|
will be returned.
|
|
Since it will usually take longer to send this
|
|
command to the device than PML allows for <Set>
|
|
operations, this object will have a return value
|
|
that does not necessarily match the value currently
|
|
received by the first device."
|
|
::= { ph2 2 }
|
|
|
|
|
|
phd2-device-memory OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to read the current values stored in
|
|
shared memory available from the paper handling device.
|
|
Additional information:
|
|
If at least one (1) external paper handling device
|
|
is attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the current memory stored in
|
|
the printer's NVRAM (non-volatile RAM) for the
|
|
first paper handling device. Currently, the
|
|
printer allocates 16 bytes for each device."
|
|
::= { ph2 4 }
|
|
|
|
|
|
phd3-device-specific-command OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to send device-specific data to the
|
|
paper handling device. The meaning of the device-
|
|
specific command is dependent on the paper handling
|
|
device and must be specified in the POS.
|
|
If the paper handling device does not accept the
|
|
command, then an <badValue> will
|
|
be returned. If the device accepts the command, it may
|
|
still be processing the command after the response has
|
|
been returned. Depending on the device, the application
|
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
|
command has completed.
|
|
Additional information:
|
|
If at least two (2) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
will be returned.
|
|
Since the data formats can vary from device to
|
|
device, this information must be documented for
|
|
each device by the manufacturer of the device.
|
|
If the device does not support this command, then
|
|
an <badValue> error message
|
|
will be returned.
|
|
Since it will usually take longer to send this
|
|
command to the device than PML allows for <Set>
|
|
operations, this object will have a return value
|
|
that does not necessarily match the value currently
|
|
received by the second device."
|
|
::= { ph3 2 }
|
|
|
|
|
|
phd3-device-memory OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to read the current values stored in
|
|
shared memory available from the paper handling device.
|
|
Additional information:
|
|
If at least two (2) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the current memory stored in
|
|
the printer's NVRAM (non-volatile RAM) for the
|
|
second paper handling device. Currently, the
|
|
printer allocates 16 bytes for each device."
|
|
::= { ph3 4 }
|
|
|
|
|
|
phd4-device-specific-command OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to send device-specific data to the
|
|
paper handling device. The meaning of the device-
|
|
specific command is dependent on the paper handling
|
|
device and must be specified in the POS.
|
|
If the paper handling device does not accept the
|
|
command, then an <badValue> will
|
|
be returned. If the device accepts the command, it may
|
|
still be processing the command after the response has
|
|
been returned. Depending on the device, the application
|
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
|
command has completed.
|
|
Additional information:
|
|
If at least three (3) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
will be returned.
|
|
Since the data formats can vary from device to
|
|
device, this information must be documented for
|
|
each device by the manufacturer of the device.
|
|
If the device does not support this command, then
|
|
an <badValue> error message
|
|
will be returned.
|
|
Since it will usually take longer to send this
|
|
command to the device than PML allows for <Set>
|
|
operations, this object will have a return value
|
|
that does not necessarily match the value currently
|
|
received by the third device."
|
|
::= { ph4 2 }
|
|
|
|
|
|
phd4-device-memory OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to read the current values stored in
|
|
shared memory available from the paper handling device.
|
|
Additional information:
|
|
If at least three (3) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the current memory stored in
|
|
the printer's NVRAM (non-volatile RAM) for the
|
|
second paper handling device. Currently, the
|
|
printer allocates 16 bytes for each device."
|
|
::= { ph4 4 }
|
|
|
|
|
|
phd5-device-specific-command OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to send device-specific data to the
|
|
paper handling device. The meaning of the device-
|
|
specific command is dependent on the paper handling
|
|
device and must be specified in the POS.
|
|
If the paper handling device does not accept the
|
|
command, then an <badValue> will
|
|
be returned. If the device accepts the command, it may
|
|
still be processing the command after the response has
|
|
been returned. Depending on the device, the application
|
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
|
command has completed.
|
|
Additional information:
|
|
If at least four (4) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
will be returned.
|
|
Since the data formats can vary from device to
|
|
device, this information must be documented for
|
|
each device by the manufacturer of the device.
|
|
If the device does not support this command, then
|
|
an <badValue> error message
|
|
will be returned.
|
|
Since it will usually take longer to send this
|
|
command to the device than PML allows for <Set>
|
|
operations, this object will have a return value
|
|
that does not necessarily match the value currently
|
|
received by the fourth device."
|
|
::= { ph5 2 }
|
|
|
|
|
|
phd5-device-memory OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to read the current values stored in
|
|
shared memory available from the paper handling device.
|
|
Additional information:
|
|
If at least four (4) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the current memory stored in
|
|
the printer's NVRAM (non-volatile RAM) for the
|
|
second paper handling device. Currently, the
|
|
printer allocates 16 bytes for each device."
|
|
::= { ph5 4 }
|
|
|
|
|
|
phd6-device-specific-command OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to send device-specific data to the
|
|
paper handling device. The meaning of the device-
|
|
specific command is dependent on the paper handling
|
|
device and must be specified in the POS.
|
|
If the paper handling device does not accept the
|
|
command, then an <badValue> will
|
|
be returned. If the device accepts the command, it may
|
|
still be processing the command after the response has
|
|
been returned. Depending on the device, the application
|
|
may need to query PHDx-DEVICE-MEMORY to see when the
|
|
command has completed.
|
|
Additional information:
|
|
If at least five (5) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
will be returned.
|
|
Since the data formats can vary from device to
|
|
device, this information must be documented for
|
|
each device by the manufacturer of the device.
|
|
If the device does not support this command, then
|
|
an <badValue> error message
|
|
will be returned.
|
|
Since it will usually take longer to send this
|
|
command to the device than PML allows for <Set>
|
|
operations, this object will have a return value
|
|
that does not necessarily match the value currently
|
|
received by the fifth device."
|
|
::= { ph6 2 }
|
|
|
|
|
|
phd6-device-memory OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to read the current values stored in
|
|
shared memory available from the paper handling device.
|
|
Additional information:
|
|
If at least five (5) external paper handling devices
|
|
are attached to the printer, then this object will
|
|
exist, otherwise <noSuchName>
|
|
should be returned.
|
|
This object returns the current memory stored in
|
|
the printer's NVRAM (non-volatile RAM) for the
|
|
second paper handling device. Currently, the
|
|
printer allocates 16 bytes for each device."
|
|
::= { ph6 4 }
|
|
|
|
|
|
north-edge-offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the number of 300 dpi dots by which the
|
|
image is shifted. Shift is relative to the leading edge
|
|
of the medium as the medium flows through the marking
|
|
engine with the side to be imaged facing the observer.
|
|
The leading edge is the North edge and the other edges
|
|
are defined by the normal compass layout of directions
|
|
with the compass facing the observer. The adjustment is
|
|
for all pages printed. A positive value moves the
|
|
image away from the leading edge of the medium. A
|
|
negative value moves the image closer to the leading
|
|
edge of the medium. The value 0 will return the image to
|
|
its factory default position.
|
|
Additional information:
|
|
The value of this object is stored in NVRAM."
|
|
::= { settings-print-media 2 }
|
|
|
|
|
|
media1-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 1 name.
|
|
Additional information:
|
|
The symbol set for this string is Roman-8."
|
|
::= { media1 1 }
|
|
|
|
|
|
media1-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 1. The
|
|
length restriction is required to allow the media name
|
|
to be displayed on the device's control panel. The
|
|
device POS must state the maximum number of characters
|
|
allowed. If the device also has a limitation on what
|
|
characters in a character set can be used (e.g. only
|
|
uppercase characters allowed), the POS should also state
|
|
character restrictions.
|
|
Additional information:
|
|
The maximum supported string length is 9 characters. If
|
|
the user entered string is too long, the device will store
|
|
the first 9 characters and will return the
|
|
<noError> status.
|
|
The characters must be in the range 20H to 7FH except 5C
|
|
cannot be used. The default symbol set is Roman-8 for
|
|
English; additional legal symbol sets are ISOLatin5,
|
|
ISOLatin2 and Windows31J. Setting this object with characters
|
|
outside of the range or of an illegal symbol set will cause an
|
|
error status of <badValue> to be returned."
|
|
::= { media1 2 }
|
|
|
|
|
|
media1-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 1 that have been printed. The
|
|
device POS should state whether this value is lost
|
|
across a power cycle or kept in NVRAM.
|
|
Additional information:
|
|
For LaserJet 4050 Series this page count is saved in NVRAM after every 10
|
|
pages. The maximum value is 4,294,967,295 which will never be reached in
|
|
normal operation.
|
|
The page count is incremented when a sheet of media is pulled from an input
|
|
tray. A duplex printed sheet will cause this counter to be incremented by
|
|
one.
|
|
The data for this object is stored in NVRAM."
|
|
::= { media1 3 }
|
|
|
|
|
|
media1-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
The engine processing characteristics that are to
|
|
be applied to this media type. Currently, 'engine
|
|
processing characteristics' denotes changes to
|
|
fusing temperature and/or transfer roller voltage.
|
|
The data for this object is stored in NVRAM."
|
|
::= { media1 4 }
|
|
|
|
|
|
media2-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 2 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media2 1 }
|
|
|
|
|
|
media2-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 2. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media2 2 }
|
|
|
|
|
|
media2-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 2 that have been printed. See
|
|
MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media2 3 }
|
|
|
|
|
|
media2-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media2 4 }
|
|
|
|
|
|
media3-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 3 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media3 1 }
|
|
|
|
|
|
media3-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 3. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media3 2 }
|
|
|
|
|
|
media3-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 3 that have been printed. See
|
|
MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media3 3 }
|
|
|
|
|
|
media3-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media3 4 }
|
|
|
|
|
|
media4-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 4 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media4 1 }
|
|
|
|
|
|
media4-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 4. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media4 2 }
|
|
|
|
|
|
media4-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 4 that have been printed. See
|
|
MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media4 3 }
|
|
|
|
|
|
media5-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 5 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media5 1 }
|
|
|
|
|
|
media5-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 5. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media5 2 }
|
|
|
|
|
|
media5-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 5 that have been printed. See
|
|
MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media5 3 }
|
|
|
|
|
|
media5-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media5 4 }
|
|
|
|
|
|
media6-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 6 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media6 1 }
|
|
|
|
|
|
media6-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 6. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media6 2 }
|
|
|
|
|
|
media6-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 6 that have been printed. See
|
|
MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media6 3 }
|
|
|
|
|
|
media7-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 7 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media7 1 }
|
|
|
|
|
|
media7-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 7. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media7 2 }
|
|
|
|
|
|
media7-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 7 that have been printed. See
|
|
MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media7 3 }
|
|
|
|
|
|
media7-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media7 4 }
|
|
|
|
|
|
media8-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 8 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media8 1 }
|
|
|
|
|
|
media8-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 8. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media8 2 }
|
|
|
|
|
|
media8-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 8 that have been printed. See
|
|
MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media8 3 }
|
|
|
|
|
|
media8-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media8 4 }
|
|
|
|
|
|
media9-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 9 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media9 1 }
|
|
|
|
|
|
media9-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 9. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media9 2 }
|
|
|
|
|
|
media9-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 9 that have been printed. See
|
|
MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media9 3 }
|
|
|
|
|
|
media9-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media9 4 }
|
|
|
|
|
|
media10-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 10 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media10 1 }
|
|
|
|
|
|
media10-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 10. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media10 2 }
|
|
|
|
|
|
media10-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 10 that have been printed.
|
|
See MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media10 3 }
|
|
|
|
|
|
media11-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 11 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media11 1 }
|
|
|
|
|
|
media11-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 11. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media11 2 }
|
|
|
|
|
|
media11-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 11 that have been printed.
|
|
See MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media11 3 }
|
|
|
|
media12-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 12 name.
|
|
Additional information:
|
|
See MEDIA1-NAME."
|
|
::= { media12 1 }
|
|
|
|
|
|
media12-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 12. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA1-SHORT-NAME."
|
|
::= { media12 2 }
|
|
|
|
|
|
media12-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 12 that have been printed.
|
|
See MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media12 3 }
|
|
|
|
|
|
media12-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media12 4 }
|
|
|
|
|
|
media13-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 13 name.
|
|
Additional information:
|
|
The maximum supported string length is 24
|
|
bytes. If the user entered string is too long,
|
|
the device will store the first 24 bytes and
|
|
return the <noError> status.
|
|
See CAUTION statement under Product Specific Use."
|
|
::= { media13 1 }
|
|
|
|
|
|
media13-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 13. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
The maximum supported string length is 9 characters. If
|
|
the user entered string is too long, the device will store
|
|
the first 9 characters and will return the
|
|
<noError> status.
|
|
The characters must be in the range 20H to 7FH except 5C
|
|
cannot be used. The default symbol set is Roman-8 for
|
|
English; additional legal symbol sets are ISOLatin5,
|
|
ISOLatin2 and Windows31J. Setting this object with characters
|
|
outside of the range or of an illegal symbol set will cause an
|
|
error status of <badValue> to be returned."
|
|
::= { media13 2 }
|
|
|
|
|
|
media13-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 13 that have been printed.
|
|
See MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA1-PAGE-COUNT."
|
|
::= { media13 3 }
|
|
|
|
|
|
media13-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media13 4 }
|
|
|
|
|
|
media14-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 14 name.
|
|
Additional information:
|
|
See MEDIA13-NAME."
|
|
::= { media14 1 }
|
|
|
|
|
|
media14-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 14. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA13-SHORT-NAME."
|
|
::= { media14 2 }
|
|
|
|
|
|
media14-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 14 that have been printed.
|
|
See MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA13-PAGE-COUNT."
|
|
::= { media14 3 }
|
|
|
|
|
|
media14-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media14 4 }
|
|
|
|
|
|
media15-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 15 name.
|
|
Additional information:
|
|
See MEDIA13-NAME."
|
|
::= { media15 1 }
|
|
|
|
|
|
media15-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 15. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA13-SHORT-NAME."
|
|
::= { media15 2 }
|
|
|
|
|
|
media15-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 15 that have been printed.
|
|
See MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA13-PAGE-COUNT."
|
|
::= { media15 3 }
|
|
|
|
|
|
media15-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media15 4 }
|
|
|
|
|
|
media16-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 16 name.
|
|
Additional information:
|
|
See MEDIA13-NAME."
|
|
::= { media16 1 }
|
|
|
|
|
|
media16-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 16. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA13-SHORT-NAME."
|
|
::= { media16 2 }
|
|
|
|
|
|
media16-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 16 that have been printed.
|
|
See MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA13-PAGE-COUNT."
|
|
::= { media16 3 }
|
|
|
|
|
|
media16-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media16 4 }
|
|
|
|
|
|
media17-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..24))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media 17 name.
|
|
Additional information:
|
|
See MEDIA13-NAME."
|
|
::= { media17 1 }
|
|
|
|
|
|
media17-short-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..9))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length restricted version of the media name 17. See
|
|
MEDIA1-SHORT-NAME for details.
|
|
Additional information:
|
|
See MEDIA13-SHORT-NAME."
|
|
::= { media17 2 }
|
|
|
|
|
|
media17-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sheets of media 17 that have been printed.
|
|
See MEDIA1-PAGE-COUNT for details.
|
|
Additional information:
|
|
See MEDIA13-PAGE-COUNT."
|
|
::= { media17 3 }
|
|
|
|
|
|
media17-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media17 4 }
|
|
|
|
|
|
prtinputdefaultindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtInputIndex corresponding to the default input
|
|
sub-unit: that is, this object selects the default source of
|
|
input media.
|
|
This value shall be -1 if there is no default input subunit specified
|
|
for the printer as a whole. In this case, the actual default
|
|
input subunit may be specified by means outside the scope of this
|
|
MIB, such as by each interpreter in a printer with multiple
|
|
interpreters.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The default input tray is determined by the printer
|
|
based on DEFAULT-MEDIA-SIZE and DEFAULT-MEDIA-NAME, and whether or
|
|
not optional trays are installed.
|
|
If Tray 1 is set in FIRST mode then the size of paper loaded in
|
|
Tray 1 is assumed to be the requested size. In this case, the printer will
|
|
pick from Tray 1 without regard to the requested size unless the
|
|
print job's paper size, paper type and tray designations exactly
|
|
match the configuration of another tray; in that case, the requested
|
|
tray will be picked."
|
|
::= { prtGeneralEntry 6 }
|
|
|
|
|
|
prtmarkerdefaultindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtMarkerIndex corresponding to the
|
|
default marker sub-unit; that is, this object selects the
|
|
default marker.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4050 Series only has one marker subunit."
|
|
::= { prtGeneralEntry 8 }
|
|
|
|
|
|
prtmediapathdefaultindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..3)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtMediaPathIndex corresponding to
|
|
the default media path; that is, the selection of the
|
|
default media path.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
If the duplex unit is not installed, the only valid
|
|
value for this object is 1; with duplex unit installed,
|
|
1-3 values are valid. 1 is simplex, 2 is
|
|
LongEdgeBindingDuplex, and 3 is ShortEdgeBindingDuplex.
|
|
If the printer is not idle, the new value of this object
|
|
may not take effect until a job boundary is reached.
|
|
If a get is done on this object before the job boundary
|
|
is reached, the value last set will be returned."
|
|
::= { prtGeneralEntry 9 }
|
|
|
|
|
|
prtcoverdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer provided cover sub-mechanism name in the
|
|
localization specified by prtGeneralCurrentLocalization.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtCoverEntry 2 }
|
|
|
|
|
|
prtcoverstatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePdoorOpen(3),
|
|
ePdoorClosed(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this cover sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML NOT-READY-DOOR-OPEN."
|
|
::= { prtCoverEntry 3 }
|
|
|
|
|
|
prtmarkermarktech OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePelectrophotographicLaser(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of marking technology used for this marking sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
ePelectrophotographicLaser is the only value that applies
|
|
for the LaserJet 4050 Series products, and this is the value that will
|
|
always be returned for this object."
|
|
::= { prtMarkerEntry 2 }
|
|
|
|
|
|
prtmarkercounterunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePimpressions(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit that will be used by the printer when reporting
|
|
counter values for this marking sub-unit. The
|
|
time units of measure are provided for a device like a
|
|
strip recorder that does not or cannot track the physical
|
|
dimensions of the media and does not use characters,
|
|
lines or sheets.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Since LaserJet 4050 Series keeps track of pages printed, the
|
|
counter unit will be defined as ePimpressions which would be
|
|
like saying pages printed."
|
|
::= { prtMarkerEntry 3 }
|
|
|
|
|
|
prtmarkerlifecount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The count of the number of units of measure counted during
|
|
the life of printer using units of measure as specified by
|
|
prtMarkerCounterUnit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML TOTAL-ENGINE-PAGE-COUNT.
|
|
The total engine page count is kept in NVRAM however
|
|
the NVRAM value is only updated every 10 impressions.
|
|
NOTE: The value returned by this OID will be incremented
|
|
every page but if power is lost between NVRAM updates,
|
|
up to 9 impressions of the page count may be lost. The
|
|
counter will be reset to zero after 999999 pages.
|
|
The page count is incremented when a sheet of media is
|
|
pulled from an input tray. A duplex printed sheet will
|
|
cause this counter to be incremented by two."
|
|
::= { prtMarkerEntry 4 }
|
|
|
|
|
|
prtmarkerpoweroncount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The count of the number of units of measure counted since the
|
|
equipment was most recently powered on using units of measure as
|
|
specified by prtMarkerCounterUnit.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerEntry 5 }
|
|
|
|
|
|
prtmarkerprocesscolorants OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of process colors supported by this marker. A
|
|
process color of 1 implies monochrome. The value of this
|
|
object and prtMarkerSpotColorants cannot both be 0. The value of
|
|
prtMarkerProcessColorants must be 0 or greater.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerEntry 6 }
|
|
|
|
|
|
prtmarkerspotcolorants OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of spot colors supported by this marker. The
|
|
value of this object and prtMarkerProcessColorants cannot
|
|
both be 0. Must be 0 or greater.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerEntry 7 }
|
|
|
|
|
|
prtmarkeraddressabilityunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit of measure of distances, as applied to the marker's
|
|
resolution.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This will always be ePtenThousandthsOfInches, no matter
|
|
what COLD-RESET-MEDIA-SIZE is because we are talking about
|
|
resolution and toner addressability, which is always dpi."
|
|
::= { prtMarkerEntry 8 }
|
|
|
|
|
|
prtmarkernorthmargin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The margin, in units identified by prtMarkerAddressabilityUnit,
|
|
from the leading edge of the medium as the medium flows
|
|
through the marking engine with the side to be imaged
|
|
facing the observer. The leading edge is the North edge
|
|
and the other edges are defined by the normal compass
|
|
layout of directions with the compass facing the
|
|
observer. Printing within the area bounded by all four
|
|
margins is guaranteed for all interpreters. The value
|
|
(-2) means unknown.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerEntry 11 }
|
|
|
|
|
|
prtmarkersouthmargin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The margin from the South edge (see prtMarkerNorthMargin)
|
|
of the medium in units identified by
|
|
prtMarkerAddressabilityUnit. Printing within the area bounded by
|
|
all four margins is guaranteed for all interpreters.
|
|
The value (-2) means unknown.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerEntry 12 }
|
|
|
|
|
|
prtmarkerwestmargin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The margin from the West edge (see prtMarkerNorthMargin) of the
|
|
medium in units identified by prtMarkerAddressabilityUnit.
|
|
Printing within the area bounded by all four margins is
|
|
guaranteed for all interpreters. The value (-2) means
|
|
unknown.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerEntry 13 }
|
|
|
|
|
|
prtmarkereastmargin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The margin from the East edge (see prtMarkerNorthMargin) of the
|
|
medium in units identified by prtMarkerAddressabilityUnit.
|
|
Printing within the area bounded by all four margins is
|
|
guaranteed for all interpreters. The value (-2) means
|
|
unknown.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerEntry 14 }
|
|
|
|
|
|
prtmarkerstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of this marker sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML NOT-READY-DESTINATION-PRINT-ENGINE and
|
|
STATUS-DESTINATION-PRINT-ENGINE.
|
|
51 = No toner cart.
|
|
49 = Low toner and toner low = stop in config menu
|
|
14 = Low toner and toner low = continue in config menu
|
|
and paper is moving.
|
|
08 = Low toner and toner low = continue in config menu
|
|
and no paper is moving.
|
|
00 = OK.
|
|
The default value assumes no malfunctions."
|
|
::= { prtMarkerEntry 15 }
|
|
|
|
|
|
prtmarkersuppliesmarkerindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtMarkerIndex corresponding to the
|
|
marking sub-unit with which this marker supply
|
|
sub-unit is associated.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4050 Series has just one marker supply, the toner
|
|
cartridge, so this value is always 1."
|
|
::= { prtMarkerSuppliesEntry 2 }
|
|
|
|
|
|
prtmarkersuppliescolorantindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtMarkerColorantIndex
|
|
corresponding to the colorant with which this
|
|
marker supply sub-unit is associated. This value
|
|
shall be 0 if there is no colorant table.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerSuppliesEntry 3 }
|
|
|
|
|
|
prtmarkersuppliesclass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePsupplyThatIsConsumed(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether this supply entity represents a supply
|
|
that is consumed or a receptacle that is filled.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
ePsupplyThatIsConsumed is the only value that applies
|
|
for the LaserJet 4050 Series products, and this is the value that will
|
|
always be returned for this object."
|
|
::= { prtMarkerSuppliesEntry 4 }
|
|
|
|
|
|
prtmarkersuppliestype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtoner(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of this supply.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
ePtoner is the only value that applies for the LaserJet 4050 Series
|
|
products, and this is the value that will always be
|
|
returned for this object."
|
|
::= { prtMarkerSuppliesEntry 5 }
|
|
|
|
|
|
prtmarkersuppliessupplyunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenthsOfGrams(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit of measure of this marker supply container/receptacle.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
ePtenthsOfGrams will always be returned for this object."
|
|
::= { prtMarkerSuppliesEntry 7 }
|
|
|
|
|
|
prtmarkercolorantmarkerindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtMarkerIndex corresponding to the
|
|
marker sub-unit with which this colorant entry is
|
|
associated.
|
|
Additional information:
|
|
LaserJet 4500 only has one marker. Therefore, the
|
|
value of these objects is always 1."
|
|
::= { prtMarkerColorantEntry 2 }
|
|
|
|
|
|
prtmarkercolorantrole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePprocess(3),
|
|
ePspot(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The role played by this colorant.
|
|
Additional information:
|
|
All LaserJet 4500 colorants are process colorants."
|
|
::= { prtMarkerColorantEntry 3 }
|
|
|
|
|
|
prtmarkercolorantvalue OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the color of this
|
|
colorant using standardized string names from ISO 10175 (DPA)
|
|
and ISO 10180 (SPDL) which are:
|
|
other
|
|
unknown
|
|
white
|
|
red
|
|
green
|
|
blue
|
|
cyan
|
|
magenta
|
|
yellow
|
|
black
|
|
Implementors may add additional string values. The naming
|
|
conventions in ISO 9070 are recommended in order to avoid
|
|
potential name clashes"
|
|
::= { prtMarkerColorantEntry 4 }
|
|
|
|
|
|
prtmarkercoloranttonality OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distinct levels of tonality realizable by a marking
|
|
sub-unit when using this colorant. This value does not
|
|
include the number of levels of tonal difference that an
|
|
interpreter can obtain by techniques such as half toning.
|
|
This value must be at least 2.
|
|
Additional information:
|
|
LaserJet 4500 supports eight bits per pixel."
|
|
::= { prtMarkerColorantEntry 5 }
|
|
|
|
|
|
|
|
prtmediapathmaxspeedprintunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePimpressionsPerHour(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit of measure used in specifying the speed of all media
|
|
paths in the printer.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
ePimpressionsPerHour is the value that will
|
|
always be returned for this object. (Print Speed is
|
|
measured in pages-per-minute (impressions per minute),
|
|
so ePimpressionsPerHour is a natural extension)."
|
|
::= { prtMediaPathEntry 2 }
|
|
|
|
|
|
prtmediapathmediasizeunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The units of measure of media size for use in calculating and
|
|
relaying dimensional values for all media paths in the printer.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMediaPathEntry 3 }
|
|
|
|
|
|
prtmediapathtype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePlongEdgeBindingDuplex(3),
|
|
ePshortEdgeBindingDuplex(4),
|
|
ePsimplex(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the media path for this media path.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML DUPLEX-INSTALLED."
|
|
::= { prtMediaPathEntry 9 }
|
|
|
|
|
|
prtmediapathdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer-provided description of this media path in
|
|
the localization specified by prtGeneralCurrentLocalization.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMediaPathEntry 10 }
|
|
|
|
|
|
prtmediapathstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of this media path.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The default values assume the printer is idle."
|
|
::= { prtMediaPathEntry 11 }
|
|
|
|
|
|
collated-originals-support OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that the printer can create multiple, collated
|
|
'originals' of a job and shows the level of support for
|
|
this capability.
|
|
cCollatedOriginals - The printer can create multiple
|
|
collated originals, or 'mopies'. This is the base
|
|
functionality required by the other collection items.
|
|
cProofAndHold - The printer saves a copy of the job
|
|
while printing the first mopy. Later, this held job can
|
|
be released and the rest of the mopies will print.
|
|
cSecurityPrint - The printer spools the job and holds
|
|
the job until the user releases the job by entering a
|
|
password at the printer's control panel.
|
|
cAutoHighlight - The printer prints the job a number
|
|
of times with a mail distribution list prepended to each
|
|
job. A different mailing address is highlighted on each
|
|
mopy.
|
|
cCollatedAtSpeed - The printer can create multiple
|
|
collated copies where all copies after the original are
|
|
printed at engine speed.
|
|
Additional information:
|
|
Indicates that the printer can create multiple, collated
|
|
originals of a job and shows the level of support for this
|
|
capability.
|
|
cCollatedOriginals - The printer can create multiple collated
|
|
originals, or mopies.
|
|
|
|
This is the base functionality required by the other
|
|
collection items. None of them are supported by Jonah.
|
|
Without disk, this object will not exist. This will be set at
|
|
boot-up initialization. If the disk fails, in any way, then
|
|
the disk error functionality will handle the situation.
|
|
|
|
The value of this object will be:
|
|
!cCollatedOriginals - Only FLASH installed
|
|
cCollatedOriginals - IDE is installed combined
|
|
with/without FLASH
|
|
cCollatedOriginals - RAMDISK is On combined with/without FLASH"
|
|
::= { status-system 42 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.7.
|
|
consumable-current-state OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cAuthLevel1(0),
|
|
cAuthLevel2(1),
|
|
cAuthLevel3(2),
|
|
cAuthLevel4(3),
|
|
cAuthLevel5(4),
|
|
cAuthLevel6(5),
|
|
cAuthLevel7(6),
|
|
cGenuineHPUnsupported(8),
|
|
cELabelDefective(9),
|
|
cELabelMissing(10),
|
|
cLowCondition(11),
|
|
cOutCondition(12),
|
|
cIncorrect(13),
|
|
cMissing(14),
|
|
cPastOutCondition(15),
|
|
cConfigurableLow(16),
|
|
cExpired(17),
|
|
cFailure(18),
|
|
cLeak(19),
|
|
cUnknownManufacturer(20),
|
|
cUnsupported(21),
|
|
cUnavailable(22),
|
|
cIncompatible(23),
|
|
cStatusAreValid(31)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This PML object returns the current state of the particular
|
|
consumable. \\
|
|
cAuthLevel1 - Consumable is at Authentication Level 1 \\
|
|
cAuthLevel2 - Consumable is at Authentication Level 2 \\
|
|
cAuthLevel3 - Consumable is at Authentication Level 3 \\
|
|
cAuthLevel4 - Consumable is at Authentication Level 4 \\
|
|
cAuthLevel5 - Consumable is at Authentication Level 5 \\
|
|
cGenuineHPUnsupported - Cartridge is GenuineHP intended for another product \\
|
|
cDefectiveMemory - Cartridge has a defective memory tag \\
|
|
cMissingMemory - Memory tag is missing from the cartridge\\
|
|
cLowCondition - Consumable has reached the engine low threshold \\
|
|
cOutCondition - Consumable has reached its out threshold \\
|
|
cIncorrect - Cartridge inserted is not the correct one \\
|
|
cMissing - Consumable is missing from the printer \\
|
|
cConfigurableLow - Consumable has reached the configurable low threshold value \\
|
|
cStatusArevalid - The status reported on other bits are
|
|
valid only if the bit is set to 1. If it is 0, the values are invalid. \\
|
|
cExpired - Is the cartridge expired, which is determined \\
|
|
by the formatter.\\
|
|
cFailure - Cartridge has failed determined by the engine. \\
|
|
cLeak - Cartridge has a leak as determined by the engine. \\
|
|
cUnknownManufacturer - the brand of the cartridge is \\
|
|
unknown as determined by the engine. \\
|
|
cUnsupported --- Cartridge is not supported as determined\\
|
|
by the engine. \\
|
|
cIncompatible - When installed consumable is incompatible with
|
|
current printer. These are the possible states and whenever the
|
|
consumable is in any of these states, the appropriate bit will
|
|
be set. The cLowCondition will be set when the consumable
|
|
reaches the engine low threshold, and cConfigurableLow will be
|
|
set when the consumable reaches the Configurable Low threshold
|
|
value. For non-cartridge supplies only cLowCondition,
|
|
cOutCondition, and cMissing will be supported "
|
|
::= { consumables 7 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.9
|
|
device-used-while-cartridge-out-override-active OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNotUsed(1),
|
|
eUsed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns eUsed if the device has ever been used while Cartridge
|
|
Out Override is activated. Merely enabling cartridge out
|
|
override will not cause eUsed to be returned. Cartridge Out
|
|
Override must be activated by a cartridge becoming out and
|
|
device must be used in that mode"
|
|
::= { consumables 9 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.11.
|
|
consumable-pages-printed-with-supply OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This PML object returns the number of pages printed with a
|
|
cartridge consumable. This PML object returns the value that
|
|
should be displayed under 'Pages Printed With This Supply' for
|
|
cartridges in color products"
|
|
::= { consumables 11 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.15.
|
|
total-kilo-pixels-per-cartridge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns the total number of kilo-pixels at 600dpi in the
|
|
cartridge. That is, the number returned by this object should
|
|
be multiplied by 1000 to determine the total number of pixels
|
|
at 600dpi in the cartridge "
|
|
::= { consumables 15 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.16
|
|
consumable-replacement-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The total number of times a consumable has been replaced.
|
|
"
|
|
::= { consumables 16 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.18
|
|
consumable-pages-since-replacement OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The total number of pages fed since the last replacement of the
|
|
consumable.
|
|
"
|
|
::= { consumables 18 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.2
|
|
supplies-at-very-low-delay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Indicates if the transition to a VERY LOW state should be
|
|
delayed by the number of pages specified in
|
|
SUPPLIES-AT-VERY-LOW-DELAY-LIMIT"
|
|
::= { consumables-status 2 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.1.
|
|
consumable-life-usage-units-remaining OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This object reports the current estimate of the number of usage
|
|
units that remain before this supply is depleted. An installed
|
|
supply that cannot report such a number will return a value of
|
|
-2. It is the reponsibility of the host application to query
|
|
each supply in order to determine an overall device
|
|
USAGE-UNITS-REMAINING number - the lowest value returned. The
|
|
unit of measure for this life estimate is determined by reading
|
|
the corresponding CONSUMABLE-LIFE-USAGE-UNITS object"
|
|
::= { consumables-life 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.2.
|
|
consumable-life-usage-units OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePagesRemaining(1),
|
|
eEstimatedPagesRemaining(2),
|
|
eUnknownUnits(3),
|
|
ePagesSinceLow(4),
|
|
ePagesSinceOut(5),
|
|
ePagesPicked(6),
|
|
ePercentLifeRemaining(7),
|
|
e4X6ImagesPrinted(8),
|
|
eEngineDropCount(9),
|
|
eEngineWebAdvances(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This object reports current usage units in use by the
|
|
corresponding CONSUMABLE-LIFE-USAGE-UNITS-REMAINING object"
|
|
::= { consumables-life 2 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.3.
|
|
consumable-life-low-threshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object is used to report and modify a threshold value
|
|
indicating the point in the life of a consumable or supply at
|
|
which a transition to a LOW state will occur"
|
|
::= { consumables-life 3 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.4.
|
|
estimated-page-yield OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns the estimated yield of the cartridge in
|
|
ESTIMATED-PAGE-YIELD-UNIT units"
|
|
::= { consumables-life 4 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.5.
|
|
estimated-page-yield-unit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
e5PercentPages(1),
|
|
eISOPages(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns the unit used for ESTIMATED-PAGE-YIELD"
|
|
::= { consumables-life 5 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.6.
|
|
supplies-at-very-low-delay-limit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object is used to report and modify a very low delay limit
|
|
value indicating the number of pages to delay the transition to
|
|
a very low state for a supply."
|
|
::= { consumables-life 6 }
|
|
|
|
printer-average-marking-agent-units-per-gram OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is used to read the marking agent units of measure
|
|
per gram. This is typically a conversion factor for converting
|
|
pixels of toner to grams. This pixels-per-gram value is used to
|
|
calculate the estimated number of pages remaining for a given
|
|
marking agent."
|
|
::= { printer-average 4 }
|
|
|
|
|
|
printer-average-marking-agent-coverage-actual OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is used to read the actual average marking agent
|
|
coverage for a given color plane. It is a real number that
|
|
represents percent coverage and will read from 0 to 100%. This
|
|
object will return the same value as
|
|
PRINTER-AVERAGE-MARKING-AGENT-COVERAGE except under certain
|
|
conditions which will be specified in the device POS."
|
|
::= { printer-average 5 }
|
|
|
|
file-system-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of memory, in bytes, used by the file system
|
|
to buffer file data.
|
|
Additional information:
|
|
Reports the amount of memory, in bytes,
|
|
reserved for use by the file system. Returns
|
|
<noSuchName> status if attempting
|
|
to access this object and there is no storage device
|
|
is installed. The values remain constant across reboots.
|
|
Possible Values:
|
|
FILE-SYSTEM-MAX-OPEN-FILES 32 512
|
|
EIO DISK 69916 198556
|
|
EIO DISK + 1 2MB Flash 88940 217580
|
|
1 2MB Flash 33052 161692"
|
|
::= { settings-file-system 1 }
|
|
|
|
|
|
file-system-test-return-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test object that will not be supported in any
|
|
released product. Setting this object allows the next
|
|
file system call return code to be specified or to
|
|
simulate uninitialized or unistalled volumes. The POS
|
|
will specify the binary format.
|
|
Additional information:
|
|
A three byte binary value. The first
|
|
byte indicates what function is being effected by
|
|
this set.
|
|
value | function
|
|
------+------------------
|
|
1 | PersFSCtl
|
|
2 | PersFSDirClose
|
|
3 | PersFSDirCreate
|
|
4 | PersFSDirDelete
|
|
5 | PersFSDirOpen
|
|
6 | PersFSDirRead
|
|
7 | PersFSDirReadStd
|
|
8 | PersFSDirRewind
|
|
9 | PersFSDirSeek
|
|
10 | PersFSDirTell
|
|
11 | PersFSFileClose
|
|
12 | PersFSFileDelete
|
|
13 | PersFSFileMove
|
|
14 | PersFSFileOpen
|
|
15 | PersFSFileRead
|
|
16 | PersFSFileSeek
|
|
17 | PersFSFileStatus
|
|
18 | PersFSFileWrite
|
|
19 | PersFSFlush
|
|
20 | PersFSVolChk
|
|
21 | PersFSVolFix
|
|
22 | PersFSVolInit
|
|
23 | PersFSVolStatus
|
|
The return value of the function being effected will
|
|
return the value -1 to indicate an error occurred.
|
|
The second byte is the
|
|
value returned by the next call to PersFSErrNo()
|
|
(after the call being effected is called). Refer to
|
|
the 'Copernicus Personality Interface Volume 2 Disk
|
|
File System' documentation for a list of values
|
|
returned by PersFSErrNo(). The third byte indicates
|
|
which call to the specified file system routine will
|
|
fail. A value of one means the first call will fail.
|
|
A value of two means the second call will fail, and
|
|
so on. Writing this object causes any previous write to
|
|
this object to be invalidated.
|
|
Note: The error triggering
|
|
mechanism is actually implemented at the message
|
|
interface to the file system rather than at the PersFSxxx()
|
|
function call interface. This is easier to do, and
|
|
it is better for NFS because NFS uses the message
|
|
interface rather than the PersFSxxx() functions.
|
|
Fortunately there is a one-to-one mapping between
|
|
messages and PersFSxxx() functions so everything
|
|
works out nicely.
|
|
The printer will uninitialize the mass storage device if
|
|
the first byte is one of the values listed below.
|
|
value | meaning
|
|
------+------------------
|
|
101 | Effects the printer state
|
|
102 | Effects the data on the device
|
|
The Moby printer supports 3 volumes zero, so the
|
|
second byte must be 0 - 2. The third byte has no meaning
|
|
and must be zero."
|
|
::= { settings-file-system 3 }
|
|
|
|
|
|
file-system-statistic-read-open OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the file system has received
|
|
requests to open a file for reading. Opening a file for
|
|
both reading and writing will cause this value to
|
|
change. The POS should state if a power cycle causes
|
|
the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed. This value is
|
|
increamented when a file is opened."
|
|
::= { status-file-system 1 }
|
|
|
|
|
|
file-system-statistic-write-open OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the file system has received
|
|
requests to open a file for writing. Opening a file for
|
|
both reading and writing will cause this value to
|
|
change. The POS should state if a power cycle causes
|
|
the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed. This value is
|
|
increamented when a file is opened."
|
|
::= { status-file-system 2 }
|
|
|
|
|
|
file-system-statistic-successful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of file system requests
|
|
that completed successfully. The POS should state if a
|
|
power cycle causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 3 }
|
|
|
|
|
|
file-system-statistic-unsuccessful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of file system requests
|
|
that completed unsuccessfully. The POS should state if
|
|
a power cycle causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 4 }
|
|
|
|
|
|
file-system-statistic-current-memory-usage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value indicating the number of bytes of RAM currently
|
|
used by the file system firmware.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed. This will veri
|
|
depending on the number and size of Mass Storage
|
|
devices installed."
|
|
::= { status-file-system 5 }
|
|
|
|
|
|
file-system-statistic-max-memory-usage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value indicating the maximum number of bytes of RAM
|
|
used by the file system firmware. The POS should state
|
|
if the value is reset to zero after a power cycle.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 6 }
|
|
|
|
file-system1-initialized OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns eTrue if a file system has been written to the
|
|
mass storage device(s) which will hold file data
|
|
contained in this file system. Returns eFalse
|
|
otherwise. Each POS needs to specify the relationship
|
|
between file systems and the physical storage devices
|
|
that can hold the data contained in those file systems.
|
|
Additional information:
|
|
This objects is only supported if a disk is
|
|
installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no disk
|
|
installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no disk installed."
|
|
::= { file-system1 1 }
|
|
|
|
|
|
file-system1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the total size, in bytes, of the mass storage
|
|
space configured to hold the file data (and file system
|
|
information) assoicated with files stored in this file
|
|
system. This refers to hardware capacity, independent
|
|
of any space consumed by the file system overhead or
|
|
user files.
|
|
Additional information:
|
|
This objects is only supported if a disk is
|
|
installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no disk
|
|
installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no disk installed."
|
|
::= { file-system1 2 }
|
|
|
|
|
|
file-system1-free-space OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the total amount, in bytes, of unused storage
|
|
space currently available to this file system.
|
|
Additional information:
|
|
This objects is only supported if a disk is
|
|
installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no disk
|
|
installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no disk installed."
|
|
::= { file-system1 3 }
|
|
|
|
|
|
file-system1-write-protect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Supports write-protecting the file system. Setting
|
|
FILE-SYSTEM-WRITE-PROTECT to eEnabled blocks any
|
|
modification of the contents of the file system.
|
|
Setting FILE-SYSTEM-WRITE-PROTECT to eDisabled allows
|
|
modification of the contents of the file system.
|
|
Additional information:
|
|
This objects is only supported if a disk is
|
|
installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get, or Set on this OID
|
|
with no disk installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform an EnableTrap, or
|
|
DisableTrap on this OID with no disk installed."
|
|
::= { file-system1 4 }
|
|
|
|
|
|
file-system2-initialize-volume OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInitializing(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to eInitializing causes file system
|
|
2 to be initialized. Reading this object indicates if
|
|
the file system is currently being initialized.
|
|
Additional information:
|
|
The hrDeviceIndex value for the mass storage
|
|
device is the same value that is used to index into the
|
|
FILE-SYSTEM sub-tree. Since this product supports
|
|
up to 3 mass storage device, and since the hrDeviceIndex
|
|
for the mass storage devices will start at 2 if the mass
|
|
storage device is installed, the FILE-SYSTEM2-INITIALIZE-VOLUME
|
|
object will be the object that allows the mass storage device to be
|
|
initialized that is the 1st device."
|
|
::= { file-system2 6 }
|
|
|
|
|
|
file-system3-initialize-volume OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInitializing(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to eInitializing causes file system
|
|
3 to be initialized. Reading this object indicates if
|
|
the file system is currently being initialized.
|
|
Additional information:
|
|
The hrDeviceIndex value for the mass storage
|
|
device is the same value that is used to index into the
|
|
FILE-SYSTEM sub-tree. Since this product supports
|
|
up to 3 mass storage device, and since the hrDeviceIndex
|
|
for the mass storage devices will start at 2 if the mass
|
|
storage device is installed, the FILE-SYSTEM3-INITIALIZE-VOLUME
|
|
object will be the object that allows the mass storage device to be
|
|
initialized that is the 2nd device."
|
|
::= { file-system3 6 }
|
|
|
|
|
|
file-system4-initialize-volume OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInitializing(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to eInitializing causes file system
|
|
4 to be initialized. Reading this object indicates if
|
|
the file system is currently being initialized.
|
|
Additional information:
|
|
The hrDeviceIndex value for the mass storage
|
|
device is the same value that is used to index into the
|
|
FILE-SYSTEM sub-tree. Since this product supports
|
|
up to 3 mass storage devices, and since the hrDeviceIndex
|
|
for the mass storage devices will start at 2 if the mass
|
|
storage device is installed, the FILE-SYSTEM4-INITIALIZE-VOLUME
|
|
object will be the object that allows the mass storage device to be
|
|
initialized that is the 3rd device."
|
|
::= { file-system4 6 }
|
|
|
|
|
|
mass-storage-resource-change-counter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter which changes when a mass storage based
|
|
resource has been added or deleted.
|
|
Additional information:
|
|
The value of this counter changes
|
|
each time the MASS-STORAGE-RESOURCE-CHANGED object
|
|
is set to eTrue. The value also changes when the
|
|
mass storage device is initialized. However, the value does not
|
|
change when a mass storage device is removed and a different
|
|
mass storage device is installed. Initializing all volumes sets
|
|
this object back to the factory default value. A reboot sets
|
|
this object back to the factory devalut value.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { mass-storage-resources 1 }
|
|
|
|
|
|
mass-storage-resource-changed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE-
|
|
COUNTER to be incremented.
|
|
Additional information:
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { mass-storage-resources 2 }
|
|
|
|
|
|
hrstoragesize OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of the storage represented by this entry,
|
|
in units of hrStorageAllocationUnits.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (printer):
|
|
Total formatter RAM.
|
|
Additional information (mass storage):
|
|
Applications can determine the size of the
|
|
installed mass storage device by getting the
|
|
hrStorageAllocationUnits object and this object. The size
|
|
of the mass storage device is these two returned values multiplied
|
|
together. Returns <noSuchName>
|
|
status if attempting to perform a Get on this OID
|
|
with no mass storage device installed."
|
|
::= { hrStorageEntry 5 }
|
|
|
|
|
|
hrdevicedescr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description of this device, including
|
|
the device's manufacturer and revision, and
|
|
optionally, its serial number.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (printer) :
|
|
The serial number is not returned with this object.
|
|
This object is not localized.
|
|
Additional information (mass storage) :
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Get on this OID
|
|
with no mass storage device installed."
|
|
::= { hrDeviceEntry 3 }
|
|
|
|
|
|
hrdeviceid OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The product ID for this device.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (printer) :
|
|
The complete OID reported by this object is:
|
|
.1.3.6.1.4.1.11.2.3.9.1.2.12
|
|
Additional information (mass storage) :
|
|
Constant. Since we don't know all the
|
|
possible registered OIDs for each mass storage device model that
|
|
could be installed in this printer, this object
|
|
always returns the unknown product ID. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrDeviceEntry 4 }
|
|
|
|
|
|
hrdeviceerrors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of errors detected on this device. It
|
|
should be noted that as this object has a SYNTAX
|
|
of Counter, that it does not have a defined
|
|
initial value. However, it is recommended that
|
|
this object be initialized to zero.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information (mass storage):
|
|
Total number of read and write errors
|
|
that have occurred since the printer was turned on.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no mass storage device
|
|
installed. Returns 0 if the mass storage device is
|
|
uninitialized."
|
|
::= { hrDeviceEntry 6 }
|
|
|
|
|
|
hrdiskstorageaccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHreadWrite(1),
|
|
eHreadOnly(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication if this long-term storage device is
|
|
readable and writable or only readable. This
|
|
should reflect the media type, any write-protect
|
|
mechanism, and any device configuration that
|
|
affects the entire device.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
This object can be set to write protect
|
|
the mass storage device, even though the host resources MIB
|
|
documents the object as read-only. Applications wanting to
|
|
know if the mass storage device is writable should get this
|
|
object. Applications wanting to change the read/write access
|
|
of the mass storage device should set this object.
|
|
If this object is set to write-protect while a file is being
|
|
written to the mass storage device, the write-protect takes effect
|
|
immediately and the new file doesn't appear in the file system.
|
|
Returns <noSuchName> status if attempting to
|
|
perform a Get on this OID with no mass storage device installed."
|
|
::= { hrDiskStorageEntry 1 }
|
|
|
|
|
|
hrdiskstoragemedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHother(1),
|
|
eHhardDisk(3),
|
|
eHramDisk(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of the type of media used in this
|
|
long-term storage device.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. Applications can determine if the
|
|
installed mass storage device is a disk or is flash by
|
|
getting this value.
|
|
Possible Values:
|
|
EIO DISK returns eHhardDisk
|
|
Ram Disk returns eHramDisk
|
|
Flash Disk returns eHother
|
|
Returns <noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrDiskStorageEntry 2 }
|
|
|
|
|
|
hrdiskstorageremoveble OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHfalse(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Denotes whether or not the disk media may be
|
|
removed from the drive.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrDiskStorageEntry 3 }
|
|
|
|
|
|
hrdiskstoragecapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total size for this long-term storage device.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
The capacity is in Kbytes. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrDiskStorageEntry 4 }
|
|
|
|
|
|
hrpartitionindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each partition on this long-
|
|
term storage device. The value for each long-term
|
|
storage device must remain constant at least from
|
|
one re-initialization of the agent to the next re-
|
|
initialization.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. The first and second index
|
|
indicates the hrDeviceIndex for this mass storage device.
|
|
The value of this object is the same as
|
|
the second index. The printer only supports one
|
|
partition per mass storage device. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrPartitionEntry 1 }
|
|
|
|
|
|
hrpartitionlabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..11))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description of this partition.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
The MS-DOS volume label. The volume
|
|
label is writable. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device installed.
|
|
This object is settable and returns the empty
|
|
string if the mass storage device has not been initialized. NOTE
|
|
the RamDisk will lose this value after a PowerCycle."
|
|
::= { hrPartitionEntry 2 }
|
|
|
|
|
|
hrpartitionid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A descriptor which uniquely represents this
|
|
partition to the responsible operating system. On
|
|
some systems, this might take on a binary
|
|
representation.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. The value returned is the
|
|
ASCII string version of the hrDeviceIndex for
|
|
this mass storage device. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrPartitionEntry 3 }
|
|
|
|
|
|
hrpartitionsize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of this partition.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
The capacity is in Kbytes. Returns the
|
|
same value as hrDiskStorageCapacity. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrPartitionEntry 4 }
|
|
|
|
|
|
hrpartitionfsindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the file system mounted on this
|
|
partition. If no file system is mounted on this
|
|
partition, then this value shall be zero. Note
|
|
that multiple partitions may point to one file
|
|
system, denoting that that file system resides on
|
|
those partitions. Multiple file systems may not
|
|
reside on one partition.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Indicates if the mass storage device has been
|
|
initialized. Applications determine if the storage device
|
|
has been initialized by getting this object. Returns zero
|
|
if the mass storage device is not
|
|
initialized, otherwise the value matches the
|
|
hrDeviceIndex value for this mass storage device.
|
|
The value indicates the
|
|
hrFileSystemTable index for the file system stored
|
|
on this partition. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device
|
|
installed."
|
|
::= { hrPartitionEntry 5 }
|
|
|
|
|
|
hrfsindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each file system local to this
|
|
host. The value for each file system must remain
|
|
constant at least from one re-initialization of
|
|
the agent to the next re-initialization.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. The index is assigned by the
|
|
person controlling the printer object definition.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no mass storage device
|
|
installed or if the file system has not been
|
|
initialized."
|
|
::= { hrFSEntry 1 }
|
|
|
|
|
|
hrfsmountpoint OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path name of the root of this file system.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device installed
|
|
or if the file system has not been initialized."
|
|
::= { hrFSEntry 2 }
|
|
|
|
|
|
hrfsremotemountpoint OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of the name and/or address of the
|
|
server that this file system is mounted from.
|
|
This may also include parameters such as the mount
|
|
point on the remote file system. If this is not a
|
|
remote file system, this string should have a
|
|
length of zero.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. This printer does not support
|
|
remote file system mounting. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device installed
|
|
or if the file system has not been initialized."
|
|
::= { hrFSEntry 3 }
|
|
|
|
|
|
hrfstype OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the type of
|
|
this file system.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device installed
|
|
or if the file system has not been initialized."
|
|
::= { hrFSEntry 4 }
|
|
|
|
|
|
hrfsaccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHreadWrite(1),
|
|
eHreadOnly(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication if this file system is logically
|
|
configured by the operating system to be readable
|
|
and writable or only readable. This does not
|
|
represent any local access-control policy, except
|
|
one that is applied to the file system as a whole.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Returns the same value as
|
|
hrDiskStorageAccess. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device installed
|
|
or if the file system has not been initialized."
|
|
::= { hrFSEntry 5 }
|
|
|
|
|
|
hrfsbootable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHfalse(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A flag indicating whether this file system is
|
|
bootable.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device installed
|
|
or if the file system has not been initialized."
|
|
::= { hrFSEntry 6 }
|
|
|
|
|
|
hrfsstorageindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the hrStorageEntry that represents
|
|
information about this file system. If there is
|
|
no such information available, then this value
|
|
shall be zero. The relevant storage entry will be
|
|
useful in tracking the percent usage of this file
|
|
system and diagnosing errors that may occur when
|
|
it runs out of space.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant. The value indicates the
|
|
hrStorageTable index for this mass storage device. Returns
|
|
<noSuchName> status if attempting
|
|
to perform a Get on this OID with no mass storage device installed
|
|
or if the file system has not been initialized."
|
|
::= { hrFSEntry 7 }
|
|
|
|
|
|
hrfslastfullbackupdate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last date at which this complete file system
|
|
was copied to another storage device for backup.
|
|
This information is useful for ensuring that
|
|
backups are being performed regularly.
|
|
If this information is not known, then this
|
|
variable shall have the value corresponding to
|
|
January 1, year 0000, 00:00:00.0, which is encoded
|
|
as (hex)'00 00 01 01 00 00 00 00'.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant.
|
|
The default value is the value defined
|
|
to represent an unknown time of January 1, year 0000,
|
|
00:00:00.0. Returns <noSuchName>
|
|
status if attempting to perform a Get on this OID
|
|
with no mass storage device installed or if the file system has not
|
|
been initialized."
|
|
::= { hrFSEntry 8 }
|
|
|
|
|
|
hrfslastpartialbackupdate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last date at which a portion of this file
|
|
system was copied to another storage device for
|
|
backup. This information is useful for ensuring
|
|
that backups are being performed regularly.
|
|
If this information is not known, then this
|
|
variable shall have the value corresponding to
|
|
January 1, year 0000, 00:00:00.0, which is encoded
|
|
as (hex)'00 00 01 01 00 00 00 00'.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
Constant.
|
|
The default value is the value defined
|
|
to represent an unknown time of January 1, year 0000,
|
|
00:00:00.0. Returns <noSuchName>
|
|
status if attempting to perform a Get on this OID
|
|
with no mass storage device installed or if the file system has not
|
|
been initialized."
|
|
::= { hrFSEntry 9 }
|
|
|
|
|
|
|
|
mio1-model-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying the I/O card.
|
|
Example: XXXX"
|
|
::= { mio1 2 }
|
|
|
|
|
|
mio1-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of the
|
|
I/O card installed in MIO/EIO slot 1. May include
|
|
serial number and firmware revision.
|
|
Additional information:
|
|
The format of the string returned is determined by
|
|
the manufacturer of the EIO device. There is no standard for content of the
|
|
string."
|
|
::= { mio1 3 }
|
|
|
|
|
|
mio1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eDiskDrive(8),
|
|
eIOCard(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
MIO/EIO slot 1. See SIMM1-TYPE for an explanation of
|
|
the enumerations."
|
|
::= { mio1 4 }
|
|
|
|
|
|
mio2-model-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying the I/O card.
|
|
Example: XXXX"
|
|
::= { mio2 2 }
|
|
|
|
|
|
mio2-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of the
|
|
I/O card installed in MIO/EIO slot 2. May include
|
|
serial number and firmware revision.
|
|
Additional information:
|
|
The format of the string returned is determined by
|
|
the manufacturer of the EIO device. There is no standard for content of the
|
|
string."
|
|
::= { mio2 3 }
|
|
|
|
|
|
mio2-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eDiskDrive(8),
|
|
eIOCard(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
MIO/EIO slot 2. See SIMM1-TYPE for an explanation of
|
|
the enumerations."
|
|
::= { mio2 4 }
|
|
|
|
mio3-model-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying the I/O card.
|
|
Example: XXXX"
|
|
::= { mio3 2 }
|
|
|
|
|
|
mio3-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of the
|
|
I/O card installed in MIO/EIO interface 3. May include
|
|
serial number and firmware revision.
|
|
Additional information:
|
|
The format of the string returned is determined by
|
|
the manufacturer of the EIO device. There is no standard for content of the
|
|
string."
|
|
::= { mio3 3 }
|
|
|
|
|
|
mio3-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eDiskDrive(8),
|
|
eIOCard(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
MIO/EIO interface 3. See SIMM1-TYPE for an explanation
|
|
of the enumerations."
|
|
::= { mio3 4 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.4.2
|
|
mio4-model-name OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns product information identifying the I/O card. Example:
|
|
XXXX"
|
|
::= { mio4 2 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.4.3
|
|
mio4-manufacturing-info OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns information describing the manufacture of the I/O card
|
|
installed in MIO/EIO interface 4. May include serial number and
|
|
firmware revision"
|
|
::= { mio4 3 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.4.4
|
|
mio4-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5),
|
|
eNonVolatileRandomAccessMemory(6),
|
|
eFlashMemory(7),
|
|
eDiskDrive(8),
|
|
eRamRom(9),
|
|
eInputPHD(10),
|
|
eOutputPHD(11),
|
|
eIOCard(12),
|
|
eBindingPHD(13),
|
|
eSDRandomAccessMemory(14),
|
|
eSRandomAccessMemory(15),
|
|
eFPMRandomAccessMemory(16),
|
|
eEDORandomAccessMemory(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns an indication of the type of option installed in
|
|
MIO/EIO interface 4. See SIMM1-TYPE for an explanation of the
|
|
enumerations"
|
|
::= { mio4 4 }
|
|
|
|
job-info-change-id OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the current value of an object in the job-info
|
|
sub-tree whose value has changed. Define the object
|
|
identifier for the object whose value has changed as
|
|
job-info.required-field.optional-field.job-id. job-info
|
|
represents the OID prefix of all objects in the job-info
|
|
sub-tree. Required-field represents the OID field value
|
|
that follows the job-info prefix. Since some objects in
|
|
the job-info sub-tree have two OID fields between the
|
|
job-info prefix and the job-id, the optional-field
|
|
represents the OID field between the required-field and
|
|
the job-id field, if present. Using this definition,
|
|
the format for the JOB-INFO-CHANGE-ID binary value can
|
|
be described as follows:
|
|
Bytes 0-3 : required-field
|
|
Bytes 4-7 : optional-field, or all zeros if there
|
|
is no optional field
|
|
Bytes 8-11: Job ID.
|
|
Bytes 12-n : The value of the object job-info.
|
|
required-field.optional-field.job-id.
|
|
All multi-byte values stored in Motorola (big-endian)
|
|
format, where the most significant byte occurs first.
|
|
Additional information:
|
|
LaserJet 4050 Series will use this object to report
|
|
changes to the job-info-pages-printed and job-info-state
|
|
objects. The required-field (bytes 0 through 3) will
|
|
designate whether the change to be reported involves the
|
|
pages printed (13) or job state (15). The optional-field
|
|
(bytes 4 through 7) will always be zeroes. The value-field
|
|
(bytes 12 through 15) will contain the new value for pages
|
|
printed or job state cast to a 32-bit integer."
|
|
::= { settings-job 3 }
|
|
|
|
|
|
hold-job-timeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time, in minutes, that the printer will wait before
|
|
automatically deleting a held job. This allows the
|
|
printer to automatically clean up jobs that have been
|
|
forgotten (held but never released).
|
|
Additional information:
|
|
This only applies to temporary held jobs, i.e., HOLD=ON or
|
|
PROOF. This is a global timer that only affects the jobs
|
|
that are sent after it is set.
|
|
A value of 0 means never delete the jobs.
|
|
Setting it to an unsupported value causes
|
|
the printer to substitute a value (listed
|
|
below) and to return <noError>
|
|
status.
|
|
LaserJet 4050 Series supports values of 0, 60, 240, 1440, and 10080
|
|
The values are as follows:
|
|
<=0 snap to 0 (disabled)
|
|
>=1 and <=150 snap to 60 (60 minutes)
|
|
>=151 and <=840 snap to 240 (4 hours)
|
|
>=841 and <=2880 snap to 1440 (1 day)
|
|
>=2881 snap to 10080 (1 week)"
|
|
::= { settings-job 10 }
|
|
|
|
|
|
current-job-parsing-id OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the printer assigned job identification for the
|
|
job currently being processed by the processing PDL sub-
|
|
system. The job ID is a monotonically increasing
|
|
number. The job ID may be reset to zero at power-up and
|
|
may roll over to zero after reaching some maximum
|
|
value.
|
|
Additional information:
|
|
A value of -1 is returned when the printer
|
|
is not parsing a job.
|
|
|
|
When data for a new job is detected, this object is
|
|
updated (the job may or may not turn out to be a Null
|
|
Job); however, the trap does not occur until the printer
|
|
determines that it is not a Null Job. (A job is considered
|
|
to be a 'null job' if it has no name or job attribute,
|
|
causes no pages to be printed, and consumes MIN_JOB_SIZE
|
|
(9) or fewer bytes.) A trapped value will differ from
|
|
the previous value by one or more.
|
|
|
|
Some job-info- objects are created when the first data
|
|
bytes are received. If the printer determines that the
|
|
job is a Null Job, the job-info- objects related to the
|
|
Null Job are deleted. LaserJet 4050 Series retains the job-info-
|
|
objects for the MAX_JOBS_IN_LIST (12) most recent jobs
|
|
that are not Null Jobs.
|
|
|
|
The first job received after power-up will have job ID 1,
|
|
and the job ID will increment to 32767 before rolling
|
|
to zero. To distinguish whether a power cycle or a
|
|
rollover causes a reduction in the job ID value, the
|
|
object prtGeneralConfigChanges can be watched and if it
|
|
increments at the same time as the drop is observed in
|
|
the value of CURRENT-JOB-PARSING-ID, then a power cycle
|
|
is the most likely cause."
|
|
::= { job-being-parsed 1 }
|
|
|
|
|
|
job-info-name1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the first part of this print job's name. The
|
|
last OID field for this dynamic object contains the job
|
|
ID.
|
|
Additional information:
|
|
The job name is the string specified by the
|
|
NAME= parameter of the @PJL JOB command which allows a
|
|
maximum of 80 characters. The first 40 characters are
|
|
in this object and the second 40 are in job-info-name2.
|
|
The symbol set is Roman-8.
|
|
|
|
When jobs are nested, the value assigned to this object
|
|
is the name provided by the most recent @PJL JOB NAME=
|
|
command. If no name is provided, a null string is
|
|
returned."
|
|
::= { job-info 1 }
|
|
|
|
|
|
job-info-name2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the second part of this print job's name. The
|
|
last OID field for this dynamic object contains the job
|
|
ID.
|
|
Additional information:
|
|
See job-info-name1."
|
|
::= { job-info 2 }
|
|
|
|
|
|
job-info-stage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates what printer sub-systems are currently
|
|
processing this print job. The last OID field for this
|
|
dynamic object contains the job ID.
|
|
cSourceSubsystem - some of the job is in the printer
|
|
I/O subsystem.
|
|
cProcessingSubsystem - some of the job is in the
|
|
printer imaging processing subsystem.
|
|
cDestinationSubsystem - some of the job is being
|
|
printed.
|
|
Additional information:
|
|
For LaserJet 4050 Series, cSourceSubsystem and
|
|
cProcessingSubsystem will always be set and cleared
|
|
together. They are set when the beginning of the
|
|
job is detected, and they are cleared when the end
|
|
of the job is parsed.
|
|
|
|
A non-printing job will never set
|
|
cDestinationSubsystem.
|
|
|
|
When a page is ready to be printed (the intermediate has
|
|
been built and the page is `closed' by the personality),
|
|
cDestinationSubsystem will be set even if a page of a
|
|
previous job is currently being printed.
|
|
cDestinationSubsystem remains set until the last page of
|
|
the job has finished printing.
|
|
|
|
If a page requires extensive processing and allows all
|
|
the previous pages of a job to complete printing,
|
|
cDestinationSubsystem will remain set until the last
|
|
page of the job has finished printing."
|
|
::= { job-info 10 }
|
|
|
|
|
|
job-info-io-source OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which I/O source, the print job was received
|
|
over. The value maps to port numbering scheme supported
|
|
in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
|
|
::= { job-info 11 }
|
|
|
|
|
|
job-info-pages-processed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of pages processed by the
|
|
processing subsystem. If neither the cSourceSubsystem
|
|
or the cProcessingSubsystem items are in the associated
|
|
JOB-INFO-STAGE object, then this object contains the
|
|
total number of pages processed for this job. The last
|
|
OID field for this dynamic object contains the job ID.
|
|
Additional information:
|
|
This object is incremented by one when a
|
|
page is processed (`closed' by the personality), regardless
|
|
of the number of pages that are printed as a result of the
|
|
single page processed. In other words, it does not matter
|
|
how many identical copies of a page are printed or no pages
|
|
may be printed if operating in silent run mode, this count
|
|
is incremented exactly once.
|
|
|
|
A page is considered processed when all of the input
|
|
data has been processed for a page (that is, when the
|
|
intermediate has been produced, and the personality has
|
|
`closed' the page. At this time, the image of the page is
|
|
not necessarily completely formed.)"
|
|
::= { job-info 12 }
|
|
|
|
|
|
job-info-pages-printed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of pages printed by the destination
|
|
subsystem. If non of the cSourceSubsystem,
|
|
cProcessingSubsystem or cDestinationSubsystem items are
|
|
in the associated JOB-INFO-STAGE object, then this
|
|
object contains the total number of pages printed for
|
|
this job. This value may increase by two each time for
|
|
duplex jobs. The last OID field for this dynamic object
|
|
contains the job ID.
|
|
Additional information:
|
|
If multiple copies of a page are printed,
|
|
each copy is counted individually."
|
|
::= { job-info 13 }
|
|
|
|
|
|
job-info-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of bytes of data processed by the
|
|
processing subsystem. If neither of the
|
|
cSourceSubsystem or cProcessingSubsystem items are in
|
|
the associated JOB-INFO-STAGE object, then this object
|
|
contains the size of this job, in bytes. The last OID
|
|
field for this dynamic object contains the job ID.
|
|
Additional information:
|
|
This count may be incremented by values
|
|
other than one as blocks of data are processed; blocks
|
|
of data (which may be as large as 2K bytes) will be
|
|
processed in a varying amount of time.
|
|
|
|
During the processing of a job and even when a job completes,
|
|
an exact count of the number of I/O bytes processed by the
|
|
job is not necessarily to be expected."
|
|
::= { job-info 14 }
|
|
|
|
|
|
job-info-state OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eAborted(3),
|
|
eWaitingForResources(4),
|
|
ePrinted(5),
|
|
eTerminating(7),
|
|
eCancelled(10),
|
|
eProcessing(11)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the state of the job. The last OID field for
|
|
this dynamic object contains the job ID.
|
|
eAborted - the print job was aborted.
|
|
eWaitingForResources - the print job requires
|
|
resources that are not currently available. Example
|
|
resources that can cause the job to wait include the
|
|
print engine or PDL processor being unavailable. The
|
|
print engine could be unavailable due to paper out,
|
|
paper jam, staple out, stapler jam, marking agent low,
|
|
output bin full, etc. The PDL processor could be
|
|
unavailable due to an off-line condition. Each printer
|
|
specific object specification should state which
|
|
conditions cause a job to be waiting for resources and
|
|
also state which objects can be retrieved by an
|
|
application to determine the exact cause of a resource
|
|
being unavailable.
|
|
ePrinted - the job has printed. The related JOB-INFO-
|
|
OUTCOME object indicates if any problems were
|
|
encountered while the job was processed.
|
|
eRetained - the job can be reprinted.
|
|
eTerminating - the job was aborted or cancelled and is
|
|
currently is terminating.
|
|
eInterrupted - the job has been interrupted. The job
|
|
can be continued.
|
|
ePaused - the job has been paused. The job can be
|
|
continuted.
|
|
eCancelled - the job has been cancelled.
|
|
eProcessing - the job is currently being printed
|
|
normally."
|
|
::= { job-info 15 }
|
|
|
|
|
|
job-info-outcome OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOk(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if any warning or error conditions were
|
|
encountered while processing the assoicated job. The
|
|
last OID field for this dynamic object contains the job
|
|
ID.
|
|
Additional information:
|
|
In LaserJet 4050 Series, warnings and errors are not recorded
|
|
in this object. Although no meaningful information can be
|
|
obtained from this object, it is kept around for the
|
|
compatibility needs of existing software."
|
|
::= { job-info 19 }
|
|
|
|
|
|
job-info-attr-1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. Attribute objects are saved
|
|
sequentially, starting with 1, after the start of a job.
|
|
If more attributes are set than there are objects to
|
|
store them, the excess JOBATTR values are ignored. If
|
|
the corresponding SET JOBATTR= command has not been
|
|
received when a get is done for this object, a status of
|
|
<noSuchName> will be returned."
|
|
::= { job-info-attribute 1 }
|
|
|
|
|
|
job-info-attr-2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 2 }
|
|
|
|
|
|
job-info-attr-3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 3 }
|
|
|
|
|
|
job-info-attr-4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 4 }
|
|
|
|
|
|
job-info-attr-5 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 5 }
|
|
|
|
|
|
job-info-attr-6 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 6 }
|
|
|
|
|
|
job-info-attr-7 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 7 }
|
|
|
|
|
|
job-info-attr-8 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 8 }
|
|
|
|
|
|
job-info-attr-9 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 9 }
|
|
|
|
|
|
job-info-attr-10 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 10 }
|
|
|
|
|
|
job-info-attr-11 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 11 }
|
|
|
|
|
|
job-info-attr-12 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 12 }
|
|
|
|
|
|
job-info-attr-13 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 13 }
|
|
|
|
|
|
job-info-attr-14 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 14 }
|
|
|
|
|
|
job-info-attr-15 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 15 }
|
|
|
|
|
|
job-info-attr-16 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 16 }
|
|
|
|
job-info-attr-17 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 17 }
|
|
|
|
|
|
job-info-attr-18 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 18 }
|
|
|
|
|
|
job-info-attr-19 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 19 }
|
|
|
|
|
|
job-info-attr-20 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 20 }
|
|
|
|
|
|
job-info-attr-21 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 21 }
|
|
|
|
|
|
job-info-attr-22 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 22 }
|
|
|
|
|
|
job-info-attr-23 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 23 }
|
|
|
|
|
|
job-info-attr-24 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 24 }
|
|
|
|
|
|
job-info-attr-25 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 25 }
|
|
|
|
|
|
job-info-attr-26 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 26 }
|
|
|
|
|
|
job-info-attr-27 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 27 }
|
|
|
|
|
|
job-info-attr-28 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 28 }
|
|
|
|
|
|
job-info-attr-29 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 29 }
|
|
|
|
|
|
job-info-attr-30 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 30 }
|
|
|
|
|
|
job-info-attr-31 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 31 }
|
|
|
|
|
|
job-info-attr-32 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 32 }
|
|
|
|
|
|
job-info-requested-originals OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of requested collated copies. The value was
|
|
supplied with the job via PJL QTY variable, the
|
|
PostScript Collate and NumCopies entries in the page
|
|
device dictionary, or via some other mechansim."
|
|
::= { job-info 24 }
|
|
|
|
|
|
job-info-page-count-current-original OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The page number being printed within the current copy of
|
|
a collated multi-copy job. This value changes when the
|
|
job-info-pages-printed changes. The job-info-pages-
|
|
printed indicates the total number of pages printed in
|
|
the job, while this object indicates the number of pages
|
|
printed for this copy of a collated multi-copy job.
|
|
Additional information:
|
|
The number of pages in the current copy of a collated
|
|
multi-copy job which have been completely printed and
|
|
safely delivered to the output bin."
|
|
::= { job-info 25 }
|
|
|
|
|
|
job-info-pages-in-original OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of pages in a single copy of a collated multi-
|
|
copy job."
|
|
::= { job-info 26 }
|
|
|
|
|
|
job-info-printed-originals OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of collated copies completely printed and
|
|
delivered to the output bin at time of query."
|
|
::= { job-info 27 }
|
|
|
|
not-ready-processing-pdl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the PDL sub-system in the device is not
|
|
ready. If there are no items in the collection (i.e. no
|
|
bits are set), then the PDL sub-system is ready. If
|
|
there is an item present, then the item indicates what
|
|
is causing the PDL sub-system to be not ready. cOffLine
|
|
indicates the PDL processing sub-system is off line.
|
|
cPrintDataMemoryOverflow indicates the print job was
|
|
sufficiently complex to use up all memory available for
|
|
processing print job data. cSoftResourceMemoryOverflow
|
|
indicates the print job contained soft resources (fonts,
|
|
macros, etc.) that over flowed the available memory."
|
|
::= { status-pdl 1 }
|
|
|
|
form-feed-needed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the PDL processing sub-system has made
|
|
marks on the current page and the source subsystem has
|
|
been idle for a device specific amount of time.
|
|
Additional information:
|
|
LaserJet 4050 Series will set this object to eTrue when it
|
|
has made marks on the current page, the IO-TIMEOUT has
|
|
expired while PCL was running in `backward-compatibility
|
|
mode' (which is caused by jobs consisting purely of PCL
|
|
data with no prepended PJL commands), and no data is pending
|
|
on another I/O. Once it is set to eTrue, more data on the
|
|
same I/O will cause this object to be set to eFalse, until
|
|
the above conditions are met again."
|
|
::= { status-pdl 2 }
|
|
|
|
|
|
jetsend-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables or disables the JetSend processing sub-system.
|
|
Additional information:
|
|
Enables or disables the JetSend processing subsystem.
|
|
The valid values are eOff and eOn. (Specifying an invalid mode
|
|
causes an <badValue> error to be returned.).
|
|
This object will be enabled in IR devices even if is does not
|
|
detect an EIO card."
|
|
::= { settings-jetsend 1 }
|
|
|
|
|
|
jetsend-contact-password OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A C structure containing the following fields:
|
|
typedef struct {
|
|
ubyte old_password[8];
|
|
ubyte new_password[8];/
|
|
} jetsend_change_contact_password_t;
|
|
where ubyte is an unsigned byte (0-255).
|
|
Additional information:
|
|
Controls access to the JetSend processing subsystem.
|
|
Password absence/presence determines whether the device will allow
|
|
a session to be established. The following C data structure
|
|
contains the relevant fields (described in subsequent paragraphs):
|
|
|
|
typedef struct {
|
|
unsigned char old_password[8];
|
|
unsigned char new_password[8];
|
|
}
|
|
|
|
Whenever the password is disabled (i.e., is zero-filled for its
|
|
entire length), the device is indicating its willingness to allow
|
|
session establishment. Whenever the password is enabled (i.e., has
|
|
one or more non-zero-filled values), the device is controlling
|
|
session establishment -- all in-progress JetSend sessions must
|
|
supply a matching password or the device will reject the in-progress
|
|
session.
|
|
|
|
To disable the password, specify the matching password via the
|
|
'old_password' field and zero-fill the 'new_password' field.
|
|
To enable the password for the first time, zero-fill the
|
|
'old_password' field and specify the new password via the
|
|
'new_password' field (the new password should not be
|
|
zero-filled; otherwise, the password will remain disabled).
|
|
To enable or change the password thereafter, specify the
|
|
matching password via the 'old_password' field and specify
|
|
the new password via the 'new_password' field (the new
|
|
desired password should not be zero-filled; otherwise,
|
|
the password will be disabled). To determine if the password
|
|
is enabled, zero-fill both the 'old_password' and 'new_password'
|
|
fields. If an error occurs, the password is enabled; otherwise,
|
|
the password is disabled.
|
|
|
|
(Specifying either an 'old_password' or 'new_password'
|
|
fields greater than eight (8) bytes causes the error
|
|
<badValue> to be returned.)
|
|
|
|
This object will be enabled in IR devices even if is does not
|
|
detect an EIO card."
|
|
::= { settings-jetsend-contact 1 }
|
|
|
|
|
|
jetsend-contact-ip-address-security OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A C structure containing the following fields:
|
|
typedef struct {
|
|
ubyte reserved[3];
|
|
ubyte command; /* command: 0 to 1 */
|
|
ubyte password[8];
|
|
ubyte IPAddress[4];
|
|
} jetsend_contact_ip_address_security_t;
|
|
where ubyte is an unsigned byte (0-255). The defined
|
|
values defined for command are:
|
|
|
|
When command is 0:
|
|
IPAddress is 0: device is locked, no one can contact
|
|
it
|
|
IPAddress is > 0: only that address is allowed to
|
|
contact the device
|
|
|
|
When command is 1:
|
|
IPAddress is 0: any device can contact it
|
|
IPAddress is > 0: any device matching this mask can
|
|
contact it. If the result of logically anding the mask
|
|
value supplied in the IPAddress field with the sending
|
|
device's IP address matches the result of logically
|
|
anding the mask value supplied in the IPAddress field
|
|
with this device's IP address, then JetSend will allow
|
|
the session to be established.
|
|
Additional information:
|
|
Controls the device or class of device(s) which may
|
|
communicate with the JetSend processing subsystem. The following C
|
|
data structure contains the relevant fields (described in subsequent
|
|
paragraphs):
|
|
|
|
typedef struct {
|
|
unsigned char reserved[3];
|
|
unsigned char command;
|
|
unsigned char password[8];
|
|
unsigned char IPAddress[4];
|
|
}
|
|
|
|
The 'reserved' field is not used and should remain zero-filled.
|
|
The 'command' field interpretation differs based on its value:
|
|
|
|
0 = Accept session(s) only from the specific device whose
|
|
IP address matches the specified IP address; all other
|
|
session request(s) from non-matching device(s) are rejected.
|
|
1 = Accept session(s) only from the specific device(s) whose
|
|
IP address(es) conform to the mask specified in the 'IPAddress'
|
|
field; all other session request(s) from device(s) with
|
|
non-matching submask(s) are rejected. (If the result of
|
|
logically AND'ing the mask value supplied in the 'IPAddress'
|
|
field with the sending device's IP address matches the result
|
|
of logically AND'ing the mask value supplied in the 'IPAddress'
|
|
field with this device's IP address, then JetSend will allow
|
|
session establishment.
|
|
|
|
Password absence/presence determines whether the device will allow
|
|
the caller to alter the IP address security. If the password is
|
|
disabled, the caller may set the 'command' and 'IPAddress' fields
|
|
directly. If the password is enabled, the caller may (re-)set the
|
|
'command' and 'IPAddress' fields only after specifying the matching
|
|
'password' field. (Refer to the aforementioned 'JETSEND-CONTACT-PASSWORD'
|
|
object ID.)
|
|
|
|
(Specifying either an invalid 'command' field value or a 'password'
|
|
field greater than eight (8) bytes or an 'IPAddress' field greater
|
|
than four (4) bytes causes the error <badValue>
|
|
to be returned.)
|
|
|
|
This object will be enabled in IR devices even if is does not
|
|
detect an EIO card."
|
|
::= { settings-jetsend-contact 2 }
|
|
|
|
|
|
host-application-available-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the amount of memory, in bytes, that the device
|
|
has available for job-related processing or resources.
|
|
Also known as driver work space (DWS) memory."
|
|
::= { status-system 59 }
|
|
|
|
|
|
held-job-user-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User name that is obtained by the driver through some
|
|
internal method or from user input.
|
|
Additional information:
|
|
The following is a general description for all the JOB-MANAGEMENT
|
|
objects described below. These object describe the attributes of the
|
|
dynamic list containing all the stored jobs on the disk available for
|
|
printing or deleting via the job-management feature. The jobs on this
|
|
list are not deleted from the disk unless explicitly specified by the
|
|
user. A print job may be specified for retention by PJL commands in the
|
|
data stream.
|
|
|
|
Following is a list of the PJL commands (i.e. these comments describe
|
|
the PJL implementation and in some cases do not reflect the PML
|
|
implementation.):
|
|
|
|
@PJL SET HOLD=OFF|ON|PROOF|STORE|PRINT
|
|
|
|
GENERAL DESCRIPTION:
|
|
|
|
This variable specifies the retention classification of the job. The
|
|
values indicate whether the job is printed immediately and/or stored.
|
|
|
|
OFF: The job is printed but not retained on disk after printing. This
|
|
is the default value.
|
|
|
|
ON: This setting may be thought of as free proof-and-hold. The
|
|
requested number of copies will be printed and the job will be
|
|
temporarily stored on disk. The job will then be available for printing
|
|
additional copies through the control panel and through PML. There will
|
|
be a limit to the number of these temporary jobs that may be stored, and
|
|
when the limit is exceeded the oldest job will be removed from the disk.
|
|
|
|
PROOF: One copy of the job is printed and remaining copies are stored
|
|
on disk. The job is then available to select for printing via the
|
|
control panel menus or PML. The job will be deleted from the disk when
|
|
the disk space is needed for another proof and hold job but only after
|
|
the additional copies have been printed. It will also be deleted when
|
|
the user sends down another proof and hold job with the same job name,
|
|
or the user explicitly deletes the job.
|
|
|
|
STORE: The job is not printed immediately but is retained on disk. The
|
|
job is available to select for printing via the control panel
|
|
|
|
DEFAULT VALUE: OFF
|
|
|
|
The value will be stored in RAM only, not in NVRAM.
|
|
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
|
The variable will appear in the PJL INFO VARIABLES list.
|
|
|
|
@PJL SET USERNAME=<80 bytes>
|
|
|
|
GENERAL DESCRIPTION:
|
|
|
|
Eighty-character user name that is obtained by the driver through some
|
|
internal method or from user input. If the job stream does not contain
|
|
a USERNAME the default value will be NO USER NAME. The driver is
|
|
responsible for determining the size of the printers control panel and
|
|
sending a string of appropriate length.
|
|
|
|
DEFAULT VALUE: NO USER NAME
|
|
|
|
The value will be stored in RAM only, not in NVRAM.
|
|
The legal PJL commands are SET and, INQUIRE. DEFAULT is not allowed.
|
|
The variable will appear in the PJL INFO VARIABLES list.
|
|
|
|
@PJL SET JOBNAME=<80 bytes>
|
|
|
|
GENERAL DESCRIPTION:
|
|
|
|
Eighty-character job name that may be generated by the driver or
|
|
obtained from user input. This value may be used in conjunction with
|
|
the USERNAME to select a job from the front panel. If the job stream
|
|
does not contain a JOBNAME, the printer will assume no job name; each
|
|
subsequent job that is sent down by the same user would replace the
|
|
users last job on disk. The driver is responsible for determining the
|
|
size of the printers control panel and sending a string of appropriate
|
|
length.
|
|
|
|
NOTE: The limit of 80 bytes is a PJL limit. The limit for PML will
|
|
be 40 bytes.
|
|
|
|
DEFAULT VALUE: NULL STRING
|
|
|
|
The value will be stored in RAM only, not in NVRAM.
|
|
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
|
The variable will appear in the PJL INFO VARIABLES list.
|
|
|
|
@PJL SET HOLDTYPE=PUBLIC|PRIVATE
|
|
|
|
GENERAL DESCRIPTION:
|
|
|
|
This variable specifies the privacy level of the job.
|
|
|
|
PUBLIC: The job does not require a PIN in order to be released for
|
|
printing. This is the default value.
|
|
|
|
PRIVATE: The job requires a PIN in order to be released for printing.
|
|
The PIN is specified by the HOLDKEY variable. If the
|
|
|
|
HOLDTYPE is set to PRIVATE, a HOLDKEY value must be specified. If no
|
|
HOLDKEY is specified, the job will be considered PUBLIC.
|
|
|
|
DEFAULT VALUE: PUBLIC
|
|
|
|
The value will be stored in RAM only, not in NVRAM.
|
|
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
|
The variable will appear in the PJL INFO VARIABLES list.
|
|
|
|
@PJL SET HOLDKEY=4 digits, 0000...9999
|
|
|
|
GENERAL DESCRIPTION:
|
|
|
|
A 4-digit string, each digit 0-9, that is specified in the job stream
|
|
and then required to be entered in order to release the job for
|
|
printing. If a HOLDTYPE is PRIVATE, a HOLDKEY value must be specified.
|
|
If no HOLDKEY value is specified, a job will be considered PUBLIC.
|
|
|
|
DEFAULT VALUE: NULL STRING
|
|
|
|
The value will be stored in RAM only, not in NVRAM.
|
|
The legal PJL commands are SET and INQUIRE. DEFAULT is not allowed.
|
|
The variable will appear in the PJL INFO VARIABLES list.
|
|
|
|
|
|
The format for the OID is as follows:
|
|
|
|
3.4.1.6.x.y
|
|
<-----> | |
|
|
| | \
|
|
/ | job-id in the system
|
|
/ \
|
|
PML_JOB_MGNT_ROOT_OID \
|
|
job attribute 1..6
|
|
|
|
x values are 1..6:
|
|
|
|
1) user-name: user name that is obtained by the driver through some
|
|
internal method or from user input.
|
|
|
|
2) job-name: job name may be generated by the driver or obtained from
|
|
user input.
|
|
|
|
3) hold: indicates the retention classification of the job. The values
|
|
indicate whether the job is printed immediately and/or stored. There
|
|
are 4 options:
|
|
OFF: The job is printed but not retained on the disk.
|
|
ON: The job is printed and stored temporarily on the disk.
|
|
STORE: The job is not printed but stored on the disk.
|
|
PROOF: One copy of the job is printed and the remaining copies are
|
|
stored on the disk.
|
|
|
|
4) holdtype: The variable specifies the security level of the job.
|
|
PUBLIC: The job does not require a PIN in order to release the job for
|
|
printing.
|
|
PRIVATE: The job requires a PIN in order to be released for printing.
|
|
|
|
5) quantity: number of copies to print. Valid values are 0..999.
|
|
|
|
6) pin: A 4 digit string, each digit is 0-9, that is specified in the
|
|
job stream and then required to be entered in order to release the job
|
|
for printing.
|
|
|
|
y : an unsigned 15 bit number which uniquely identifies the job. The job
|
|
id for the job remains the same for the job until it is deleted from the
|
|
held jobs list.
|
|
|
|
|
|
For example, the OID below is asking for the user name of the
|
|
job whose id is 3. The application would issue:
|
|
|
|
OID
|
|
get 3.4.1.6.1.3
|
|
|
|
For example, the <getnext> OID values sequence is as follows:
|
|
|
|
OID returned OID
|
|
getnext 3.4.1.6 3.4.1.6.1.1
|
|
getnext 3.4.1.6.1.1 3.4.1.6.1.2
|
|
getnext 3.4.1.6.2.1 3.4.1.6.2.2
|
|
...
|
|
getnext 3.4.1.6.1.6 3.4.1.6.1.7
|
|
getnext 3.4.1.6.2.1 3.4.1.6.2.2
|
|
getnext 3.4.1.6.5.2828 3.4.1.6.6.1
|
|
|
|
NOTE: for example above, job id 2828 is the last job in the list of
|
|
held jobs.
|
|
...
|
|
|
|
Also supported is <getnext> on the job attributes:
|
|
OID returned OID
|
|
getnext 3.4.1.6.1 3.4.1.6.1.1
|
|
getnext 3.4.1.6.6 3.4.1.6.6.1"
|
|
::= { held-job-info 1 }
|
|
|
|
|
|
held-job-job-name OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The job name may be generated by the driver or obtained
|
|
from user input."
|
|
::= { held-job-info 2 }
|
|
|
|
|
|
held-job-retention OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHoldOff(1),
|
|
eHoldOn(2),
|
|
eHoldStore(3),
|
|
eHoldProof(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the retention classification of the job. The
|
|
values indicate whether the job is printed immediately
|
|
and/or stored. There are 4 options:
|
|
OFF: The job is printed but not retained on the disk.
|
|
ON: The job is printed and stored temporarily on the disk.
|
|
PROOF: One copy of the job is printed and the remaining copies are stored on the disk.
|
|
STORE: The job is not printed but stored on the disk."
|
|
::= { held-job-info 3 }
|
|
|
|
|
|
held-job-security OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHoldTypePublic(1),
|
|
eHoldTypePrivate(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The variable specifies the security level of the job.
|
|
PUBLIC: The job does not require a PIN in order to release the job for printing.
|
|
PRIVATE: The job requires a PIN in order to be released for printing."
|
|
::= { held-job-info 4 }
|
|
|
|
|
|
held-job-quantity OBJECT-TYPE
|
|
SYNTAX INTEGER(1..999)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of copies to print."
|
|
::= { held-job-info 5 }
|
|
|
|
|
|
held-job-pin OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..4))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string that is specified in the job stream and then
|
|
required to be entered in order to release the job for
|
|
printing. PIN stands for Personal Identification
|
|
Number.
|
|
Additional information:
|
|
Must be a 4 digit string, each digit must be 0..9 or a null string
|
|
if there is no pin."
|
|
::= { held-job-info 6 }
|
|
|
|
|
|
held-job-print OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instructs the printer to schedule the specified held job
|
|
for printing with the specified number of copies. The
|
|
job-id is used to identify which job to print. A held
|
|
job can also be printed from the control panel.
|
|
Additional information:
|
|
Bytes 0-3 is the job id of the job to print.
|
|
Bytes 4-7 is the number of copies to print."
|
|
::= { held-job-control 1 }
|
|
|
|
|
|
held-job-delete OBJECT-TYPE
|
|
SYNTAX INTEGER(0..32768)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instructs the printer to delete the specified held job
|
|
from the list. The job-id is used to identify which job
|
|
to delete. A held job can also be deleted from the
|
|
control panel.
|
|
Additional information:
|
|
"
|
|
::= { held-job-control 2 }
|
|
|
|
|
|
held-job-set-queue-size OBJECT-TYPE
|
|
SYNTAX INTEGER(0..50)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the maximum number of jobs which can be stored in
|
|
the held job list.
|
|
Additional information:
|
|
Sets the size of the temporary job lists queue."
|
|
::= { held-job-control 3 }
|
|
|
|
|
|
held-job-enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables or disables Job Retention (Job Hold). The valid
|
|
values are eDisabled and eEnabled. (Specifying an
|
|
invalid mode causes an <badValue>
|
|
error to be returned.) When eDisabled is specified all
|
|
Job Retention (Hold, Proof, Store, PIN Printing) is
|
|
disabled. When eEnabled is specified, the Job Retention
|
|
characteristics of a given job are defined by the PJL
|
|
variable SET HOLD.
|
|
Additional information:
|
|
When disabled, currently held jobs are not removed,
|
|
but must be explicitly removed through the Control Panel
|
|
or the PML object HELD-JOB-DELETE."
|
|
::= { held-job-control 4 }
|
|
|
|
|
|
usage-printer-total-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total printer charge for all paper sizes printed."
|
|
::= { printer-accounting 2 }
|
|
|
|
|
|
usage-average-toner-coverage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports the average toner area coverage of all pages
|
|
printed over the life of the device. Counts pixels on
|
|
each page, divides pixel count by pixels possible on a
|
|
page to give the percentage of coverage, and keeps a
|
|
rolling average percent weighted by area printed."
|
|
::= { printer-accounting 3 }
|
|
|
|
|
|
usage-staple-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..930576247)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of staples used."
|
|
::= { printer-accounting 4 }
|
|
|
|
|
|
usage-instructions-line1 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..40))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The first line of usage instructions for the device
|
|
user.Appears on Line 1 of the usage page."
|
|
::= { printer-accounting 5 }
|
|
|
|
|
|
usage-instructions-line2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..40))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The second line of usage instructions for the device
|
|
user.Appears on Line 1 of the usage page."
|
|
::= { printer-accounting 6 }
|
|
|
|
|
|
usage-instructions-line3 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..40))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The third line of usage instructions for the device
|
|
user.Appears on Line 1 of the usage page."
|
|
::= { printer-accounting 7 }
|
|
|
|
|
|
usage-instructions-line4 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..40))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fourth line of usage instructions for the device
|
|
user.Appears on Line 1 of the usage page."
|
|
::= { printer-accounting 8 }
|
|
|
|
|
|
scanned-media-simplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..930576247)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of simplex pages scanned, for this media
|
|
size.
|
|
Additional information:
|
|
The 5 usage (simplex/duplex count, simplex/duplex click
|
|
charge and paper size total) objects described here and
|
|
below detail the usage for the scanner for each paper
|
|
size defined in the PCL Implementor's Guide and in the
|
|
Media Size Table in the hpmib.txt. The OID binding is
|
|
based on the click attribute and paper size.
|
|
For example:
|
|
|
|
The format for the OID is as follows:
|
|
|
|
3.4.1.5.x.y
|
|
<-----> | |
|
|
| | \
|
|
/ | paper size
|
|
/ \
|
|
PRINTER-CLICK_TOTALS ROOT \
|
|
OID click attribute 1..5
|
|
|
|
x values are 1..5:
|
|
|
|
1) simplex count
|
|
2) simplex click charge
|
|
3) duplex count
|
|
4) duplex click charge
|
|
5) printer or scanner paper size total (i.e. depends if the
|
|
root OID is referrring to the printer or scanner).
|
|
|
|
y : paper size as defined in the Media Size Table in the
|
|
hpmib.txt
|
|
|
|
The click charge objects are of data type real and have a single
|
|
digit of precision. Setting these objects to more than a single
|
|
digit of precision will cause truncation at a single digit, for
|
|
example, if click charge is set to 15.475 and later retrieved with
|
|
a get, the value will be 15.400 for this object."
|
|
::= { scanned-media-usage 1 }
|
|
|
|
|
|
scanned-media-simplex-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Charge for each simplex page printed in this media
|
|
size."
|
|
::= { scanned-media-usage 2 }
|
|
|
|
|
|
scanned-media-duplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..930576247)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of duplex pages scanned, for this media
|
|
size."
|
|
::= { scanned-media-usage 3 }
|
|
|
|
|
|
scanned-media-duplex-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Charge for each duplex page scanned, for this media
|
|
size."
|
|
::= { scanned-media-usage 4 }
|
|
|
|
|
|
scanned-media-total-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total charge for pages scanned, for this media
|
|
size."
|
|
::= { scanned-media-usage 5 }
|
|
|
|
|
|
usage-scanner-total-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total scanner charge or cost for all paper sizes
|
|
scanned."
|
|
::= { scanner-accounting 2 }
|
|
|
|
|
|
scan-contrast OBJECT-TYPE
|
|
SYNTAX INTEGER(-127..127)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Behaves as SCL's 'Set Scanner Contrast Level' command
|
|
which is used for setting the scanner contrast level.
|
|
Range is 0..100.
|
|
Additional information:
|
|
There are 11 different tonemap that will
|
|
be used on scan images to change the contrast. Software
|
|
can set the contrast setting to -125, -100, -75, -50, -25,
|
|
0, 50, 75, 100, and 125 to select the different tonemaps.
|
|
A user can also set the value to -127, which is a special
|
|
mode used by manufacturing to tell the device to use all
|
|
linear tonemaps and to perform no gamma correction. The
|
|
scan pml object does not snap the pml scan-contrast. However,
|
|
the contrast setting is mapped to the correct tonemap within
|
|
the device."
|
|
::= { settings-scanner 1 }
|
|
|
|
|
|
scan-resolution OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"struct {
|
|
unsigned_32bit x_res; /* 1st four bytes; big endian */
|
|
unsigned_32bit y_res; /* 2nd four bytes; big endian */
|
|
}
|
|
Sets the scanning resolution. The x and y resolutions
|
|
in this object are in fixed-point with 16 bits of
|
|
fraction, and 16 bits of integer, and are in dots per
|
|
inch. X is horizontal; Y is vertical.
|
|
Examples of computing x_res and y_res:
|
|
300 dots/inch:round(300 * 65536) = 19660800
|
|
16 dots/mm: round(16 * 25.4 * 65536) = 26633830.
|
|
If the device does not support the given combination,
|
|
then it'll select the nearest supported values in a
|
|
device-dependent manner (documented in the POS).
|
|
Additional information:
|
|
The 4-pack device will support only: 100,
|
|
150, 200, 300 and 600. The Host SW may scale the image to
|
|
many more resolutions. If an invalid resolution setting
|
|
is passed to the device or the setting is greater than
|
|
the max value(600ppi), the device will set the resolution
|
|
to the default value. If the resolution setting is not
|
|
100, 150, 200, 300 or 600, the value is snapped up. For
|
|
instance, if the value is < 100, the resolution is snapped
|
|
to 100. If the value is between 101-149, the value is
|
|
snapped to 150, etc. NOTE: The last 16 bits of the
|
|
horizontal and vertical settings are ignored. Only the
|
|
first 16 bits of the horizontal and vertical resolution
|
|
setting are used."
|
|
::= { settings-scanner 2 }
|
|
|
|
|
|
scan-pixel-data-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eBiLevelThesholded(1),
|
|
eGrey256(8),
|
|
e24BitColor(24)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the method used when scanning.
|
|
eBiLevelThesholded - One bit per pixel, using simple
|
|
thresholding of greyscale scan data.
|
|
eBiLevelHalfToned - One bit per pixel, using some kind
|
|
of half-toning technique (such as dithering or error-
|
|
diffusion) to approximate greyscale scan data.
|
|
eGrey16 - 4 bits per pixel to represent 16 shades of
|
|
grey.
|
|
eGrey64 - 6 bits per pixel to represent 64 shades of
|
|
grey.
|
|
e3BitColor - 1 bit thresholded per Red, Green, and
|
|
Blue plane.
|
|
eGrey128 - 7 bits per pixel to represent 128 shades of
|
|
grey.
|
|
eGrey256 - 8 bits per pixel to represent 256 shades of
|
|
grey.
|
|
e24BitColor - 24 bits per pixel, 8 bits for Red, 8 bit
|
|
for Green, and 8 bits for Blue."
|
|
::= { settings-scanner 3 }
|
|
|
|
|
|
scan-compression OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eCompressNone(1),
|
|
eCompressDefault(2),
|
|
eCompressionMMR(5),
|
|
eCompressionJPEG(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of data compression applied to the
|
|
image data in the scanning upload session."
|
|
::= { settings-scanner 4 }
|
|
|
|
|
|
scan-compression-factor OBJECT-TYPE
|
|
SYNTAX INTEGER(0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the level of compression to be applied to the
|
|
scanned image data for upload. Range is normalized to
|
|
be between 0..100. The device POS determines the
|
|
mapping of the normalized scale to the actual Q factor
|
|
for JPEG.
|
|
Additional information:
|
|
The 4-pack will use the
|
|
SCAN-COMPRESSION-FACTOR for JPEG as described above
|
|
in the General Description."
|
|
::= { settings-scanner 5 }
|
|
|
|
|
|
scan-upload-error OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error status of the image scanning upload session."
|
|
::= { settings-scanner 6 }
|
|
|
|
|
|
scan-upload OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eScanUploadIdle(1),
|
|
eScanUploadStart(2),
|
|
eScanUploadActive(3),
|
|
eScanUploadAborted(4),
|
|
eScanUploadDone(5),
|
|
eScanUploadNewPage(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Handshake mechanism between host and device to initiate
|
|
scan operation and coordinate the transfer of scanned
|
|
image data to the host. This object serves both as an
|
|
indicator of scan upload activity as well as a trigger
|
|
for the host to alter scan upload progress. The
|
|
handshake is on a per page basis to allow greater host
|
|
control.
|
|
eScanUploadIdle - indicates the scan upload activity
|
|
is not occurring. Host setting this object to
|
|
eScanUploadIdle from eScanUploadActive will cause the
|
|
scan upload activity to be prematurely terminated. Host
|
|
may set object to this state at any time. Device sets
|
|
object to this state only upon initial power up but will
|
|
otherwise never set to this state of its own accord.
|
|
eScanUploadStart - indicates host requesting to
|
|
commence a scan to host operation. Host may set object
|
|
to this state from eScanUploadIdle or
|
|
eScanUploadNewPage. Device will not set object to this
|
|
state of its own accord.
|
|
eScanUploadActive - indicates scan upload activity is
|
|
occurring. The device sets object to this state to
|
|
indicate host may commence receiving scanned image data.
|
|
During this state, the device will be writing scanned
|
|
image data to the I/O channel.
|
|
eScanUploadAborted - indicates the scanning and scan
|
|
upload activity has terminated in error state. This
|
|
value is set by the device. This state is not settable
|
|
by the host. The host should transition this state to
|
|
eScanUploadIdle.
|
|
eScanUploadDone - indicates the device is signaling
|
|
successful completion of scan upload activity and there
|
|
are no more document pages in the scanner/ADF. The
|
|
application should set this object to eScanUploadIdle.
|
|
eScanUploadNewPage - indicates the device is signaling
|
|
successful completion of scan upload activity for the
|
|
current page and there remains at least one page in the
|
|
scanner/ADF available for scanning. Host may choose to
|
|
begin scan upload cycle by setting object to
|
|
eScanUploadStart or end the cycle by setting object to
|
|
eScanUploadIdle.
|
|
Additional information:
|
|
eScanUploadNewPage - indicates
|
|
the device is signaling successful completion
|
|
of scan upload activity for the current page. There
|
|
may be a page in the device or not. The device will
|
|
wait to prefeed another page until the application sets
|
|
the object to eScanUploadStart. This was to fix
|
|
a bug on HP LaserJet 1100 that a prefed page would cause a jam
|
|
if the application set the object to eScanUploadIdle.
|
|
The application could not create another scan job until
|
|
the prefed page was removed.
|
|
|
|
Host may choose to begin scan upload cycle by
|
|
setting object to eScanUploadStart or end the cycle
|
|
by setting object to eScanUploadIdle."
|
|
::= { settings-scanner 12 }
|
|
|
|
|
|
default-scanner-margin-left OBJECT-TYPE
|
|
SYNTAX INTEGER(0..5088)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the left scanner margin. The unit of measure should
|
|
be documented in the device POS.
|
|
Additional information:
|
|
The margin value must be a multiple of 4
|
|
for alignment reasons. If the entered value is not
|
|
a multiple of 4, the resolution value will be snapped
|
|
down to the closest value divisible by 4."
|
|
::= { settings-scanner 16 }
|
|
|
|
|
|
default-scanner-margin-right OBJECT-TYPE
|
|
SYNTAX INTEGER(32..5120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the right scanner margin. The unit of measure
|
|
should be documented in the device POS.
|
|
Additional information:
|
|
The margin value must be a multiple of 4
|
|
for alignment reasons. If the entered value is not
|
|
a multiple of 4, the resolution value will be snapped
|
|
down to the closest value divisible by 4."
|
|
::= { settings-scanner 17 }
|
|
|
|
|
|
scanner-accessory-serial-number OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the serial number for the scanner accessory.
|
|
If this is a writable object, the POS should indicate
|
|
the maximum supported string length. This string should
|
|
only use characters from the US-ASCII code set.
|
|
Additional information:
|
|
The serial number is 5 digit decimal number."
|
|
::= { settings-scanner 18 }
|
|
|
|
|
|
scanner-accessory-model-number OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Model number of the scanner accessory. This string
|
|
should only use characters from the US-ASCII code set.
|
|
Additional information:
|
|
Model number for the Fujitsu scanner."
|
|
::= { settings-scanner 19 }
|
|
|
|
|
|
scanner-accessory-adf-sheet-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of sheets that have been fed through the
|
|
Automatic Document Feed (ADF) accessory.
|
|
Additional information:
|
|
The Automatic Document Feed (ADF) count is
|
|
incremented each time a sheet feeds through the
|
|
ADF."
|
|
::= { settings-scanner 20 }
|
|
|
|
|
|
scanner-accessory-flatbed-scan-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of scans performed by a flatbed scanner
|
|
accessory.
|
|
Additional information:
|
|
The count is only incremented when a sheet is
|
|
scanned on the FLATBED."
|
|
::= { settings-scanner 21 }
|
|
|
|
|
|
scanner-accessory-cleaning-interval OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Recommended cleaning interval in units of sheets
|
|
scanned.
|
|
Additional information:
|
|
Recommended cleaning interval is in units of sheets
|
|
scanned."
|
|
::= { settings-scanner 22 }
|
|
|
|
|
|
scanner-accessory-cleaning-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of sheets scanned since the last cleaning was
|
|
performed.
|
|
Additional information:
|
|
The number of sheets that have gone through the
|
|
ADF since the last cleaning was performed."
|
|
::= { settings-scanner 23 }
|
|
|
|
|
|
scanner-accessory-maintenance-interval OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Recommended maintenance interval in units of sheets
|
|
scanned.
|
|
Additional information:
|
|
Recommended maintenance interval is in units of sheets
|
|
scanned."
|
|
::= { settings-scanner 24 }
|
|
|
|
|
|
scanner-accessory-maintenance-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of sheets scanned since the last maintenance
|
|
was performed.
|
|
Additional information:
|
|
The number of sheets that have gone through the
|
|
ADF since the last maintenance was performed."
|
|
::= { settings-scanner 25 }
|
|
|
|
|
|
scanner-accessory-rom-revision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ROM revision of the scanner accessory firmware.
|
|
Additional information:
|
|
ROM revision of the Fujitsu scanner is
|
|
downloaded from the scanner after the attached
|
|
scanner establishes communications to the
|
|
printer."
|
|
::= { settings-scanner 26 }
|
|
|
|
|
|
scanner-accessory-copy-processor-boot-revision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Boot ROM revision of scanner copy processor firmware.
|
|
Boot code to initialize the copy processor, establish
|
|
communications with the scanner, and load the runtime
|
|
code.
|
|
Additional information:
|
|
Boot ROM revision of the Pixel Magic - Copy
|
|
Processor firmware is downloaded from the scanner
|
|
after the attached scanner establishes
|
|
communications to the printer."
|
|
::= { settings-scanner 27 }
|
|
|
|
|
|
scanner-accessory-copy-processor-runtime-revision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revision of the runtime firmware for the scanner copy
|
|
processor. Runtime code which retrieves scanned data
|
|
from the scanner and sends it to other devices such as a
|
|
printer or PC host.
|
|
Additional information:
|
|
Revision of Pixel Magic - Copy Processor
|
|
firmware shipped on the disk which is download
|
|
into RAM for execution."
|
|
::= { settings-scanner 28 }
|
|
|
|
|
|
scanner-accessory-service-agent-revision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revision of scanner service agent firmware. Service
|
|
agent which accepts scanned data and processes scanner
|
|
copy processor requests, resident in a device such as a
|
|
printer or PC host.
|
|
Additional information:
|
|
Revision of the Scanner Service Agent firmware
|
|
shipped on the disk as a Service Provider entity
|
|
to retrieve scanned data from the scanner."
|
|
::= { settings-scanner 29 }
|
|
|
|
|
|
scanner-accessory-control-panel-user-interface-revision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revision of the control panel user interface firmware.
|
|
Additional information:
|
|
Revision of the copy processor user interface
|
|
firmware shipped on the disk."
|
|
::= { settings-scanner 30 }
|
|
|
|
|
|
scanner-accessory-nvram OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the contents of the NVRAM (Non-Volatile RAM)
|
|
located in the scanner accessory.
|
|
Additional information:
|
|
Read bytes 0..39 of the NVRAM in the
|
|
scanner. The Fujitsu Controller board has a
|
|
total of 128 bytes of NVRAM."
|
|
::= { settings-scanner 33 }
|
|
|
|
|
|
scanner-accessory-nvram2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the second part of the contents of the NVRAM
|
|
(Non-Volatile RAM) located in the scanner accessory.
|
|
Additional information:
|
|
Read bytes 40..79 of the NVRAM in the
|
|
scanner. The Fujitsu Controller board has a
|
|
total of 128 bytes of NVRAM."
|
|
::= { settings-scanner 34 }
|
|
|
|
|
|
scanner-accessory-nvram3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the third part of the contents of the NVRAM
|
|
(Non-Volatile RAM) located in the scanner accessory.
|
|
Additional information:
|
|
Read bytes 80..119 of the NVRAM in the
|
|
scanner. The Fujitsu Controller board has a
|
|
total of 128 bytes of NVRAM."
|
|
::= { settings-scanner 35 }
|
|
|
|
|
|
scanner-accessory-nvram4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the fourth part of the contents of the NVRAM
|
|
(Non-Volatile RAM) located in the scanner accessory.
|
|
Additional information:
|
|
Read bytes 120..127 of the NVRAM in the
|
|
scanner. The Fujitsu Controller board has a
|
|
total of 128 bytes of NVRAM."
|
|
::= { settings-scanner 36 }
|
|
|
|
|
|
ui-add-option OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lets the host application set up target (eg.scan) destinations.
|
|
The destinations can be a host network address and/or an
|
|
application to be launched on that host. The string sent
|
|
down has a list of 'KEYWORD=value;' items. The data sent
|
|
down also contains a string to be displayed in the device
|
|
LCD display. The device POS specifies the number of strings
|
|
that can be handled (eg. 20) and the replacement/expiration
|
|
policy as new target destinations are added.
|
|
Additional information:
|
|
For push scanning on the 4-pack, there will be a
|
|
limitation to the number of unique strings sent to the device
|
|
via UI-ADD-OPTION. A host registers for push scanning by using
|
|
the UI-ADD-OPTION object. HP Laserjet 3200 will limit the number of hosts
|
|
registered for push scanning to 20. HP LaserJet 1220 will have a
|
|
limitation of 1. Another limitation for the 4-pack is that the
|
|
DISPLAY value must be at most 18 characters. This limitation is
|
|
due to the control panel display. "
|
|
::= { settings-scanner 37 }
|
|
|
|
|
|
ui-select-option OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Triggers a job from the device based on the option selected."
|
|
::= { settings-scanner 38 }
|
|
|
|
|
|
ui-delete-option OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lets the host application delete target eg. scan
|
|
destinations that were setup with UI-ADD-OPTION.
|
|
The host sends down the entire string that was
|
|
sent earlier. The firmware looks for an exact
|
|
match in its lists and deletes the requested
|
|
option.
|
|
Additional information:
|
|
Removes an existing option only if it is
|
|
uniquely matched by the given object value."
|
|
::= { settings-scanner 42 }
|
|
|
|
|
|
scanner-jam-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates a count of the total pages jammed in the scanner'slifetime."
|
|
::= { settings-scanner 43 }
|
|
|
|
|
|
scanner-adf-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates a count of the total pages scanned through the ADF on the
|
|
device. This may include scan to host jobs, copyjobs, and fax jobs. If
|
|
only the total pages scanned to the host are wanted, use
|
|
SCAN-ADF-PAGE-COUNT."
|
|
::= { settings-scanner 44 }
|
|
|
|
|
|
scan-adf-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the total pages scanned through the ADF to the host from the
|
|
device. If the total pages scanned through the scanner are needed for
|
|
all features, including copy and fax jobs, use the
|
|
SCANNER-ADF-PAGE-COUNT object."
|
|
::= { settings-scanner 45 }
|
|
|
|
|
|
scan-image-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eText(1),
|
|
ePhoto(2),
|
|
eMixed(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the image type of the scan data."
|
|
::= { settings-scanner 46 }
|
|
|
|
|
|
scan-subsample OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFourToOneToOne(1),
|
|
eFourToTwoToTwo(2),
|
|
eFourToThreeToThree(3),
|
|
eFourToFourToFour(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the subsampling used for Scan Data. 4:1:1, 4:2:2, and
|
|
4:3:3 subsampling are used to modify the scan image quality and amount
|
|
of scan data by reducing the number of samples or pixels of the
|
|
luminous and chrominance data."
|
|
::= { settings-scanner 47 }
|
|
|
|
|
|
scanner-retrieve-scanline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object facilitates the sending of a scan line of data from the
|
|
scanner to a host. It grabs either raw or corrected data.
|
|
SERVICE-PASSWORD must be set correctly to use this object.
|
|
cScannerRequestRawScanLine - This is set by the host in order to
|
|
signal to the firmware that it wants an scan line of raw (no PRNU or
|
|
DSNU correction)data to be sent back up to the host.
|
|
cScannerRequestCorrectedScanLine - This is set by the host in order to
|
|
signal to the firmware that it wants a scan line of corrected (PRNU or
|
|
DSNU correction) data to be sent back up to the host.
|
|
cScannerSendDataRequest - This is set by firmware to indicate that it
|
|
has acquired the scan line from scan engine and is ready to send the
|
|
data to the host.
|
|
cScannerSendDataOK - This is set by the host to
|
|
indicate that it is ready to receive the data from the device.
|
|
cScannerSendDataDone - This is set by the firmware to indicate that
|
|
the transfer of data is complete.
|
|
cScannerPickSheet - This is set by the
|
|
host to tell the device to pick and stage the sheet of paper in the
|
|
ADF.
|
|
cScannerFlushSheet - This is set by the host to tell the device to
|
|
flush the sheet of paper currently in the device.
|
|
Additional information:
|
|
This object is meant to be used by Manufacturing
|
|
in order to facilitate the sending of a scan line of data from
|
|
the scanner over HDT. It
|
|
grabs either raw or corrected data."
|
|
::= { settings-scanner 48 }
|
|
|
|
|
|
scanner-motor-control OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects is set to the number of steps that the scan motor should move.
|
|
SERVICE-PASSWORD must be setcorrectly to use this object.
|
|
Additional information:
|
|
This objects is set to the number of steps that
|
|
the scan motor should move. It is meant to be used by Manufacturing
|
|
in order to position the scanner shipping blocks."
|
|
::= { settings-scanner 49 }
|
|
|
|
|
|
scan-height OBJECT-TYPE
|
|
SYNTAX INTEGER(0..25200)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to set the height of a scan image in Decapoints. The use of
|
|
Decapoints as units of measure eliminates the need for the user to
|
|
understand the scanner mechanics and the device supported resolutions.
|
|
Additional information:
|
|
This object will be used to set the height of the
|
|
scan image. The height will be entered using the
|
|
measurement of 1/720th of an inch. This will eliminate
|
|
the host being tied to the scanner mechanics and needing
|
|
to know what resolutions and number of lines the device
|
|
supports."
|
|
::= { settings-scanner 50 }
|
|
|
|
|
|
scanner-scanline-statistics OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to obtain statistics about the scan line
|
|
that was previously obtained using the SCANNER-RETRIEVE-SCANLINE
|
|
object. Just as SERVICE-PASSWORD must be set correctly for
|
|
SCANNER-RETRIEVE-SCANLINE, it must be set correctly to use this
|
|
object as well.
|
|
Additional information:
|
|
This object is used to obtain statistics about
|
|
the scan line that was previously grabbed using the SCANNER_
|
|
RETRIEVE_SCANLINE object, max string is 256 bytes. The format
|
|
is the following: max red value; position; min red value; position;
|
|
max red pixel to pixel difference; position; red mean; max blue value;
|
|
position; min blue value; position; max blue pixel to pixel difference;
|
|
position; blue mean; max green value; position; min green value;
|
|
position; max green pixel to pixel difference; position; green mean;"
|
|
::= { settings-scanner 51 }
|
|
|
|
|
|
scan-control-descriptor OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the control language and formats supported for this scanner."
|
|
::= { settings-scanner 52 }
|
|
|
|
|
|
scan-gamma-correction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A 32-bit quantity that indicates the gamma correction to
|
|
use on the scan image. The first 16 bits indicate the
|
|
integral portion of the gamma correction. The last 16
|
|
bits indicate the fraction portion in units of 1/65536.
|
|
An example is gamma correction value of 2.2 will be
|
|
representedas 0x00023333 (2 & 13107/65536ths)).
|
|
|
|
The 4-pack products (HP Laserjet 3200, HP Laserjet 1220, HP Laserjet 2200 & HP Laserjet 1200)
|
|
software will set the gamma correction to be applied on
|
|
the scan data. IPE SW will request a value of 1.0, which
|
|
indicates no gamma correction. TWAIN software will request a
|
|
value of 2.2 for grayscale scans and 2.9 for color scans.
|
|
|
|
The device pos will indicate any deviation from the
|
|
above description.
|
|
Additional information:
|
|
Indicates the gamma correction to use on the
|
|
scan image. The first 16 bits indicate the integral portion
|
|
of the gamma correction. The last 16 bits indicate the fraction
|
|
portion and in units of 1/65536. An example is gamma correction
|
|
value of 2.2 will be represented as 0x00023333 (2 & 13107/65536ths). "
|
|
::= { settings-scanner 53 }
|
|
|
|
|
|
scan-pad-image OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the scan image should be padded with white data
|
|
or not."
|
|
::= { settings-scanner 54 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.1.63
|
|
scanner-accessory-total-copy-pages-printed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This relates to the number of copy pages printed on a device.
|
|
The output sheet that is duplexed (made 2- sided) should be
|
|
counted as 2 pages"
|
|
::= { settings-scanner 63 }
|
|
|
|
scan-flatbed-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object tracks the page count for the pages scanned from
|
|
the flatbed."
|
|
::= { settings-scanner 73 }
|
|
|
|
|
|
scanner-flatbed-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object tracks the page count for the pages scanned for all
|
|
jobs from the flatbed. This includes scan to host jobs, fax
|
|
jobs, and copy jobs. "
|
|
::= { settings-scanner 74 }
|
|
|
|
|
|
scanner-modular-hardware OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Used to specify whether optional hardware is installed or not.
|
|
Additional information:
|
|
This HP LaserJet MFP uses this object to allow
|
|
a host to query whether or not it has an ADF installed,
|
|
Letter/A4 flatbed, or Legal flatbed."
|
|
::= { settings-scanner 75 }
|
|
|
|
|
|
scanner-clock-edge-modifiers OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object accesses a table used by firmware to modify clock
|
|
edge values for CCD scanner modules.
|
|
Additional information:
|
|
This object accesses a table used by firmware to modify
|
|
clock edge values for CCD scanner modules."
|
|
::= { settings-scanner 84 }
|
|
|
|
|
|
scan-clock-edges OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Returns a table of clock edges used by the scanner.
|
|
Additional information:
|
|
Returns a table of clock edges used by the scanner."
|
|
::= { settings-scanner 85 }
|
|
|
|
|
|
scan-emulate-copy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eYes(1),
|
|
eNo(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this object to eYes will cause firmware to run the next
|
|
scan job as if it were a copy job, using copy values for
|
|
scanner h/w and image processing, and then return the data to
|
|
the host as if it were a scan job. Setting this object to eNo
|
|
will cause firmware to process scan jobs in the normal way.
|
|
Additional information:
|
|
Setting this object to eYes will cause firmware to run
|
|
the next scan job as if it were a copy job, using copy
|
|
values for scanner h/w and image processing, and then
|
|
return the data to the host as if it were a scan job.
|
|
Setting this object to eNo will cause firmware to
|
|
process scan jobs in the normal way."
|
|
::= { settings-scanner 86 }
|
|
|
|
|
|
scan-calibration-target OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eWhiteSheet(1),
|
|
ePlaten(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used by the host to check which type of calibration
|
|
this scan device supports. The device pos will describe the meaning
|
|
and intent of each type of scan calibration supported.
|
|
Additional information:
|
|
This object is used by the host to check which
|
|
type of calibration the firmware supports. This is in
|
|
anticipation of the fact that the initial release of HP Laserjet 3200
|
|
will be calibrated off of a sheet, but the 'Rest of World'
|
|
release will be calibrated off of the platen."
|
|
::= { scan-calibration 18 }
|
|
|
|
|
|
not-ready-source-scanner OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether and why the scanner is not ready. A
|
|
set bit indicates a problem.
|
|
Additional information:
|
|
ISSUES: HP LaserJet 1100 only used
|
|
cScannerFeederJam. Tahiti does not have
|
|
an ADF sensor. Can cScannerFeederEmpty still
|
|
be used (i.e. when the device tries to pull
|
|
a page, but the ADF is empty or a mispick
|
|
occurred). cInvalidScannerMediaSize may be used.
|
|
If a page is longer that 33 inches normally this would be
|
|
shown to the host as a Jam. However, can the device
|
|
use cInvalidScannerMediaSize instead?"
|
|
::= { status-scanner 1 }
|
|
|
|
|
|
scan-resolution-range OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enumerates the range of selectable scanning resolutions.
|
|
Format as follows: Each supported resolution is in the
|
|
format: (m)x(n) where m describes the x dpi resolution
|
|
along the paper width. n describes the y dpi resolution
|
|
along the paper length. A scanner that supports several
|
|
resolutions would enumerate each resolution separated by
|
|
a comma. A scanner that supports a continuous
|
|
resolution range would format its range as: (m1-m2)x(n1-
|
|
n2) where m1 < m2, n1 < n2 "
|
|
::= { status-scanner 3 }
|
|
|
|
|
|
scan-calibration-download OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the state of the calibration
|
|
operation.
|
|
cScanCalibrationIdle - indicates that calibration is not
|
|
in progress.
|
|
cScanCalibrationStart - This state is set by host to
|
|
request calibration initiation. Device should not set to
|
|
this state.
|
|
cScanCalibrationActive - Indicates device is in
|
|
calibration mode. Device sets cScanCalibrationActive to
|
|
signal calibration is in process.
|
|
cScanCalibrationAborted - Set by device to indicate
|
|
calibration was prematurely terminated. Set by host when
|
|
a calibration error occurs.
|
|
cScanCalibrationSendDataRequest - Set by host when host
|
|
wants to send data to the device.
|
|
cScanCalibrationSendDataRequestOK - Set by the device to
|
|
tell the host that the device is ready to accept data.
|
|
cScanCalibrationSendDataRequestDone -Set by the device
|
|
to indicate the data was received by the device.
|
|
cScanCalibrationRequestScanBuffer - Set by the host to
|
|
request a buffer from the device.
|
|
cScanCalibrationDone - Set by the host to inform the
|
|
device calibration is complete.
|
|
The sequence of bits being set and the restrictions for
|
|
setting bits should be documented in the device POS.
|
|
Additional information:
|
|
This object was originally defined for
|
|
use on HP LaserJet 1100. HP Laserjet 3200 we will not be using
|
|
values 3-6. These are no longer applicable since
|
|
the calibration is completely contained within firmware."
|
|
::= { status-scanner 5 }
|
|
|
|
|
|
scan-calibration-error OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNoError(1),
|
|
eUnknownCalibrationError(2),
|
|
eScannerFeederEmpty(3),
|
|
eLowMemory(4),
|
|
eWriteFailed(5),
|
|
eScannerBusy(6),
|
|
eADFMispick(7),
|
|
eADFJam(8),
|
|
eUncorrectablePixels(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Error status of the most recent calibration session.
|
|
eNoError(1) - The calibation was successful.
|
|
eUnknownCalibrationError(2) - An unknown error
|
|
occurred.
|
|
eScannerFeederEmpty(3) - The feeder contained nothing to
|
|
scan.
|
|
eLowMemory(4) - Insufficient memory available to
|
|
complete the calibration.
|
|
eWriteFailed(5) - Write to NVRAM failure.
|
|
eScannerBusy(6) - Scanner is busy.
|
|
Detailed information about the cause and remedy for each
|
|
error should be documented in the device POS.
|
|
Additional information:
|
|
This object was originally defined for use on
|
|
HP LaserJet 1100. We are proposing the new enums number 7-9.
|
|
Note: Option 9 would only be set during a factory calibration
|
|
to indicate that at least one pixel was not correctable by
|
|
the digital calibration factors."
|
|
::= { status-scanner 6 }
|
|
|
|
|
|
scanner-button-status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the scanner button has been pressed. The value
|
|
changes to eOn(2) when the button is pressed. The host
|
|
acknowledges the button press by setting the value to
|
|
eOff(1)."
|
|
::= { status-scanner 7 }
|
|
|
|
|
|
scanner-lamp-gain-value OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Provides PWM and analog gain for the color channels. The range
|
|
will vary based on scan mode. The device specific POS should
|
|
describe the valid range. The format is the following:
|
|
PWM value; red analog gain; green analog gain; blue analog
|
|
gain.
|
|
Additional information:
|
|
The range will vary based on scan mode. The values
|
|
will differ from those of San Diego. The initial value
|
|
can be obtained at the start of warmup and the final
|
|
value can be obtained at the end of warmup. The warmup period is about
|
|
2 minutes. The format is the following PWM value; red analog gain;
|
|
green analog gain; blue analog gain;. The valid values for PWM value
|
|
are 580 - 730 and the valid values for analog gains are 1.00-5.80.
|
|
The gains are reported with accuracy to 2 decimal places.
|
|
A sample return value would be '584;1.00;1.34;1.00;' "
|
|
::= { status-scanner 8 }
|
|
|
|
|
|
scanner-light-monitor-window OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Provides the pixel at which the LMW starts, as the ratio of the
|
|
average LMW value to the six pixel average value. The device
|
|
specific pos should specify the valid ranges for each value.
|
|
The format is the following:
|
|
LMW position; ratio of LMWavg to 6 pixel avg.
|
|
Additional information:
|
|
Provides the pixel at which the LMW starts as well as
|
|
the ratio of the average LMW value over a 6 pixel average value.
|
|
A algebraic representation of this ratio is:
|
|
Average of Light Monitor Window pixels
|
|
______________________________________
|
|
Average of 6 test point pixels
|
|
|
|
The 6 test point pixels do not inlcude any of the Light Monitor Window.
|
|
A sample return value would be '50;0.059;'. "
|
|
::= { status-scanner 9 }
|
|
|
|
|
|
scanner-reference-position OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Provides 3 pairs of x,y coordinates within a specified range of
|
|
the calibrate reference position. The device specific POS
|
|
should specify the valid ranges. The format is the following:
|
|
'x;y;x;y;x;y'
|
|
Additional information:
|
|
Provides x,y coordinates within 1/300 of a line of the
|
|
calibrate reference position. The 3 locations in order that are
|
|
reported are the 1st Reference Mark, the 2nd Reference Mark, and
|
|
the Document Origin. A sample return value would be
|
|
80,471;2523,2914;80,471;1;34326;27,32;193;35748;28,27;194;0,0;0;0;0;0;0;0;0,0;0;0;0;0;0;0;0,0;0;0,0;0;0;0
|
|
The extra 0's on the end are used specifically to gather information during
|
|
the cimation process. "
|
|
::= { status-scanner 10 }
|
|
|
|
|
|
scanner-sensor-manufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Reports the scan sensor manufacturer. The device specific POS
|
|
should list valid manufacturers.
|
|
Additional information:
|
|
Reports the scan sensor manufacturer. The device specific
|
|
POS should list valid manufacturers."
|
|
::= { status-scanner 11 }
|
|
|
|
|
|
rpc-test-return-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test object that will not be supported in any
|
|
released product. Setting this object allows the next
|
|
RPC call return code to be specified. The POS will
|
|
specify the binary format.
|
|
Additional information:
|
|
The format of the binary data is a one
|
|
of three formats. The first format is no binary
|
|
data, which indicates the next RPC reply should not
|
|
be modified. The other two formats are described in
|
|
RFC 1057 and encoded using XDR (i.e. the value is
|
|
the data used to instead of the actual RPC reply).
|
|
The second format is when reply_stat is MSG_ACCEPTED
|
|
and accept_stat is something other than SUCCESS.
|
|
The third format is when reply_stat is MSG_DENIED.
|
|
Notice that all RPC replies that do not contain any
|
|
'results' are supported."
|
|
::= { settings-rpc 1 }
|
|
|
|
|
|
rpc-bind-protocol-address OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Array of Berkeley sockets style protocol addresses used
|
|
to bind RPC to a communications protocol family.
|
|
Setting an instance of this array object to a zero
|
|
length binary value disables the transport protocol
|
|
indicated by that instance. All multi-bytes fields are
|
|
in network (or big-endian) order. Bytes 1 and 2
|
|
indicate the transport protocol. Some of the transport
|
|
protocol mapping information can be found in RFC 1010
|
|
Assigned Numbers. A list of interesting transport
|
|
protocol number mappings include:
|
|
Protocol | Number
|
|
---------+-------
|
|
UDP/IP | 17
|
|
IPX | 1000
|
|
MLC | 4660
|
|
Bytes 3 and 4 indicate the address family. The address
|
|
family uses the same mapping as the BSD sockets address
|
|
family. A list of interesting address family mappings
|
|
include:
|
|
Address Family | Number
|
|
---------------+-------
|
|
Internet | 2
|
|
NetWare | 6
|
|
MLC | 22136
|
|
The format the fifth and following bytes is dependent on
|
|
the address family. For the Internet address family,
|
|
bytes 5 and 6 contain the port number, bytes 7 through
|
|
10 contain the IP address, and the following eight bytes
|
|
are unused. For NetWare, bytes 5 through 8 are the
|
|
network number, bytes 9 through 14 are the node number,
|
|
and bytes 15 and 16 are the socket number.
|
|
Additional information:
|
|
The length of the binary value is zero
|
|
if the instance of an object in the rpc-bind-protocol-address
|
|
array is not in use. An unfortunate side effect of the
|
|
implementation is initializing the mass storage device sets this object
|
|
back to the factory default value.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { settings-rpc 2 }
|
|
|
|
|
|
rpc-statistic-successful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of RPC requests that
|
|
completed successfully (reply_data stat is SUCCESS).
|
|
The POS should state if a power cycle causes the counter
|
|
is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc 1 }
|
|
|
|
|
|
rpc-statistic-unsuccessful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of RPC requests that
|
|
completed unsuccessfully (reply_data stat is not
|
|
SUCCESS). The POS should state if a power cycle causes
|
|
the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc 2 }
|
|
|
|
|
|
rpc-bound-protocol-address OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An array of Berkeley sockets style protocol addresses
|
|
that the NFS service has been bound to successful. The
|
|
format is that same as the array of RPC-BIND-PROTOCOL-
|
|
ADDRESS of objects.
|
|
Additional information:
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc 3 }
|
|
|
|
mount-test-return-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test object that will not be supported in any
|
|
released product. Setting this object allows the next
|
|
mount call return code to be specified. The POS will
|
|
specify the binary format.
|
|
Additional information:
|
|
A one byte binary value. The
|
|
byte indicates what procedure is being effected by
|
|
this set.
|
|
value | function
|
|
------+------------------
|
|
1 | Mount will return an fhstatus of 0.
|
|
2 | Dump will return an empty table."
|
|
::= { settings-mount 1 }
|
|
|
|
nfs-server-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of memory, in bytes, used by the Network File
|
|
System server to buffer file data.
|
|
Additional information:
|
|
Reports the amount of memory, in bytes,
|
|
reserved for use by the NFS server. An unfortunate
|
|
side effect of the implementation is initializing
|
|
the mass storage device sets this object back to the factory
|
|
default value. Also includes the memory used by
|
|
other firmware components in addition to the NFS
|
|
server. Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { settings-nfs-server 1 }
|
|
|
|
|
|
nfs-server-read-size OBJECT-TYPE
|
|
SYNTAX INTEGER(256..1500)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum amount of data transferred in one NFS server
|
|
read data call.
|
|
Additional information:
|
|
An unfortunate side effect of the
|
|
implementation is initializing the mass storage device
|
|
sets this object back to the factory default value.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed. Rebooting causes
|
|
this value to reset to factory default.
|
|
value < 256 snaps to 256
|
|
value > 1500 snaps to 1500"
|
|
::= { settings-nfs-server 2 }
|
|
|
|
|
|
nfs-server-write-size OBJECT-TYPE
|
|
SYNTAX INTEGER(256..1500)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum amount of data transferred in one NFS server
|
|
write data call.
|
|
Additional information:
|
|
An unfortunate side effect of the
|
|
implementation is initializing the mass storage device sets this object
|
|
back to the factory default value.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { settings-nfs-server 3 }
|
|
|
|
|
|
nfs-server-test-return-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test object that will not be supported in any
|
|
released product. Setting this object allows the next
|
|
NFS call return code to be specified. The POS will
|
|
specify the binary format.
|
|
Additional information:
|
|
A three byte binary value. The first
|
|
byte indicates what procedure is being effected by
|
|
this set.
|
|
value | function
|
|
------+------------------
|
|
1 | GetAttr
|
|
2 | SetAttr
|
|
3 | reserved
|
|
4 | Lookup
|
|
5 | reserved
|
|
6 | Read
|
|
7 | reserved
|
|
8 | Write
|
|
9 | Create
|
|
10 | Remove
|
|
11 | Rename
|
|
12 | reserved
|
|
13 | reserved
|
|
14 | MkDir
|
|
15 | RmDir
|
|
16 | ReadDir
|
|
17 | StatFS
|
|
The second byte is the stat value returned by the next
|
|
call to procedure specified by the value of the
|
|
first byte. The second byte can not be zero. Refer
|
|
to RFC 1094 for a list of stat values. The third byte
|
|
indicates
|
|
which call to the specified file system routine will
|
|
fail. A value of one means the first call will fail.
|
|
A value of two means the second call will fail, and
|
|
so on. Writing this object causes any previous write to
|
|
this object to be invalidated."
|
|
::= { settings-nfs-server 4 }
|
|
|
|
|
|
nfs-server-statistic-successful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of NFS requests that
|
|
completed without error. The POS should state if a
|
|
power cycle causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-nfs-server 1 }
|
|
|
|
|
|
nfs-server-statistic-unsuccessful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of NFS requests that
|
|
completed with an NFS status other than NFS_OK (0). The
|
|
POS should state if a power cycle causes the counter is
|
|
be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-nfs-server 2 }
|
|
|
|
|
|
nfs-server-statistic-current-memory-usage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value indicating the number of bytes of RAM currently
|
|
used by the NFS firmware.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-nfs-server 4 }
|
|
|
|
|
|
nfs-server-statistic-max-memory-usage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value indicating the maximum number of bytes of RAM
|
|
used by the NFS firmware. The POS should state if the
|
|
value is reset to zero after a power cycle.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-nfs-server 5 }
|
|
|
|
|
|
rpc-bind-test-return-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test object that will not be supported in any
|
|
released product. Setting this object allows the next
|
|
RPC bind call return code to be specified. The POS will
|
|
specify the binary format.
|
|
Additional information:
|
|
A one byte value.
|
|
value | meaning
|
|
------+------------------
|
|
1 | Next GetPort or GetAddr will receive port 0
|
|
| (indicating the service is not supported).
|
|
2 | Next Dump will receive an empty table."
|
|
::= { settings-rpc-bind 1 }
|
|
|
|
|
|
rpc-bind-statistic-successful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of RPC bind (RPC program
|
|
number 100000, version 2) requests that completed
|
|
successfully. The POS should state if a power cycle
|
|
causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc-bind 1 }
|
|
|
|
|
|
rpc-bind-statistic-unsuccessful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of RPC bind (RPC program
|
|
number 100000, version 2) requests that completed
|
|
unsuccessfully. The POS should state if a power cycle
|
|
causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc-bind 2 }
|
|
|
|
|
|
xip-statistic-processed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of XIP requests that
|
|
were processed. The POS should state if a power cycle
|
|
causes the counter is be reset to zero.
|
|
Additional information:
|
|
The number of XIP datagrams that have
|
|
been received by the XIP service. Reset to the
|
|
factory default value after a power cycle. Returns
|
|
<noSuchName> status if attempting
|
|
to access this object and there is no storage device
|
|
is installed."
|
|
::= { status-xip 1 }
|
|
|
|
|
|
xip-statistic-data-in-dropped OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter indicating the number of XIP data in datagrams
|
|
that were dropped (typically due to the printer being
|
|
flooded with XIP requests ). The POS should state if a
|
|
power cycle causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-xip 2 }
|
|
|
|
|
|
prtinterpreterlangfamily OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePlangPCL(3),
|
|
ePlangPJL(5),
|
|
ePlangPS(6),
|
|
ePlangAutomatic(37),
|
|
ePlangPCLXL(47)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The family name of a Page Description Language (PDL) or
|
|
control language which this interpreter in the printer can
|
|
interpret or emulate.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
ePlangAutomatic refers to the `super-language'
|
|
made available by implicit language switching."
|
|
::= { prtInterpreterEntry 2 }
|
|
|
|
|
|
prtinterpreterlanglevel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The level of the language which this interpreter is
|
|
interpreting or emulating. This might contain a value like
|
|
'5e' for an interpreter which is emulating level 5e of the PCL
|
|
language. It might contain '2' for an interpreter which is
|
|
emulating level 2 of the PostScript language. Similarly it
|
|
might contain '2' for an interpreter which is emulating level
|
|
2 of the HPGL language.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML PCL-VERSION."
|
|
::= { prtInterpreterEntry 3 }
|
|
|
|
|
|
prtinterpreterlangversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date code or version of the language which this interpreter
|
|
is interpreting or emulating.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML FW-ROM-DATECODE, PJL-DATECODE,
|
|
PCL-DATECODE and PS-DATECODE
|
|
|
|
These values are derived from the dateCode field of the personality
|
|
entities. (ePlangAutomatic uses the PJL dateCode.)"
|
|
::= { prtInterpreterEntry 4 }
|
|
|
|
|
|
prtinterpreterdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string to identify this interpreter in the localization
|
|
specified by prtGeneralCurrentLocalization as opposed to the
|
|
language which is being interpreted. It is anticipated that
|
|
this string will allow manufacturers to unambiguously identify
|
|
their interpreters.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
These values are obtained from the persName fields
|
|
of the personality entities (except for the hard-coded value
|
|
of 'Automatic Language Switching'.)
|
|
|
|
These strings are not localized."
|
|
::= { prtInterpreterEntry 5 }
|
|
|
|
|
|
prtinterpreterversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date code, version number, or other product specific
|
|
information tied to this interpreter. This value is
|
|
associated with the interpreter, rather than with the version
|
|
of the language which is being interpreted or emulated.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Same as prtInterpreterLangVersion."
|
|
::= { prtInterpreterEntry 6 }
|
|
|
|
|
|
prtinterpreterdefaultorientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePportrait(3),
|
|
ePlandscape(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current orientation default for this interpreter. This
|
|
value may be overridden for a particular job (e.g., by a
|
|
command in the input data stream).
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The value of the system's DEFAULT-ORIENTATION is
|
|
set or retrieved without regard to interpreters. Setting this
|
|
object for one interpreter will change it for all installed
|
|
interpreters.
|
|
|
|
The valid values are ePportrait and ePlandscape. Attempting
|
|
to set the orientation to a different value will cause
|
|
<badValue> to be returned."
|
|
::= { prtInterpreterEntry 7 }
|
|
|
|
|
|
prtinterpreterfeedaddressability OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum interpreter addressability in the feed
|
|
direction in 10000 prtMarkerAddressabilityUnits (see
|
|
prtMarkerAddressabilityFeedDir ) for this interpreter.
|
|
The value (-1) means other and specifically indicates
|
|
that the sub-unit places no restrictions on this parameter.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtInterpreterEntry 8 }
|
|
|
|
|
|
prtinterpreterxfeedaddressability OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum interpreter addressability in the cross feed
|
|
direction in 10000 prtMarkerAddressabilityUnits (see
|
|
prtMarkerAddressabilityXFeedDir) for this interpreter.
|
|
The value (-1) means other and specifically indicates
|
|
that the sub-unit places no restrictions on this
|
|
parameter.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtInterpreterEntry 9 }
|
|
|
|
|
|
prtinterpreterdefaultcharsetin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePcsASCII(3),
|
|
ePcsISOLatin1(4),
|
|
ePcsISOLatin2(5),
|
|
ePcsISOLatin5(12),
|
|
ePcsISOLatin6(13),
|
|
ePcsISO4UnitedKingdom(20),
|
|
ePcsISO11SwedishforNames(21),
|
|
ePcsISO15Italian(22),
|
|
ePcsISO17Spanish(23),
|
|
ePcsISO21German(24),
|
|
ePcsISO60DanishNorwegian(25),
|
|
ePcsISO69French(26),
|
|
ePcsUnicodeIBM2039(1004),
|
|
ePcsWindows30Latin1(2000),
|
|
ePcsWindows31Latin1(2001),
|
|
ePcsWindows31Latin2(2002),
|
|
ePcsWindows31Latin5(2003),
|
|
ePcsHPRoman8(2004),
|
|
ePcsAdobeStandardEncoding(2005),
|
|
ePcsPC850Multilingual(2009),
|
|
ePcsPCp852(2010),
|
|
ePcsPC8CodePage437(2011),
|
|
ePcsPC8DNDanishNorwegian(2012),
|
|
ePcsHPPC8Turkish(2014),
|
|
ePcsHPLegal(2017),
|
|
ePcsHPDeskTop(2021),
|
|
ePcsMacintosh(2027),
|
|
ePcsPC775Baltic(2087),
|
|
ePcsWindows1257Baltic(2257)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default coded character set for input octets
|
|
encountered outside a context in which the Page
|
|
Description Language established the interpretation
|
|
of the octets. (Input octets are presented to the
|
|
interpreter through a path defined in the channel group.)
|
|
This value shall be (2) if there is no default.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The object corresponding to PCL has read-write access;
|
|
For all other interpreters, the object is read-only.
|
|
|
|
The above list corresponds to the following symbol sets as they
|
|
appear on the Control Panel:
|
|
|
|
ePcsASCII( 3) - ISO-6
|
|
ePcsISOLatin1( 4) - ISO L1
|
|
ePcsISOLatin2( 5) - IS L2
|
|
ePcsISOLatin5( 12) - ISO L5
|
|
ePcsISOLatin6( 13) - ISO L6
|
|
ePcsISO4UnitedKingdom( 20) - ISO-4
|
|
ePcsISO11SwedishforNames( 21) - ISO-11
|
|
ePcsISO15Italian( 22) - ISO-15
|
|
ePcsISO17Spanish( 23) - ISO-17
|
|
ePcsISO21German( 24) - ISO-21
|
|
ePcsISO60DanishNorwegian( 25) - ISO-60
|
|
ePcsISO69French( 26) - ISO-69
|
|
ePcsUnicodeIBM2039(1004) - PC-1004
|
|
ePcsWindows30Latin1( 2000) - WIN 3.0
|
|
ePcsWindows31Latin1( 2001) - WIN L1
|
|
ePcsWindows31Latin2( 2002) - WIN L2
|
|
ePcsWindows31Latin5( 2003) - WIN L5
|
|
ePcsHPRoman8( 2004) - ROMAN-8
|
|
ePcsAdobeStandardEncoding( 2005) - PS TEXT
|
|
ePcsPC850Multilingual( 2009) - PC-850
|
|
ePcsPCp852( 2010) - PC-852
|
|
ePcsPC8CodePage437( 2011) - PC-8
|
|
ePcsPC8DNDanishNorwegian( 2012) - PC-8DN
|
|
ePcsHPPC8Turkish( 2014) - PC-8 TK
|
|
ePcsHPLegal( 2017) - LEGAL
|
|
ePcsHPDeskTop( 2021) - DESKTOP
|
|
ePcsMacintosh(2027) - MC TEXT
|
|
ePcsPC775Baltic( 2087) - PC-775
|
|
ePcsWindows1257Baltic( 2257) - WINBALT"
|
|
::= { prtInterpreterEntry 10 }
|
|
|
|
|
|
prtinterpreterdefaultcharsetout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePcsNoDefault(2),
|
|
ePcsASCII(3),
|
|
ePcsHPRoman8(2004),
|
|
ePcsAdobeStandardEncoding(2005)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default character set for data coming from this interpreter
|
|
through the printer's output channel (i.e. the 'backchannel').
|
|
This value shall be (2) if there is no default.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtInterpreterEntry 11 }
|
|
|
|
|
|
prtinterpretertwoway OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePyes(3),
|
|
ePno(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether or not this interpreter returns information
|
|
back to the host.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtInterpreterEntry 12 }
|
|
|
|
|
|
energy-star OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the Energy Star sleep value. If the
|
|
value is greater than zero, then the device will go into
|
|
energy saving sleep mode after the print engine has been
|
|
idle for the number of seconds specified by this object.
|
|
A value of zero means Energy Star is disabled and the
|
|
device will not go to sleep based on print engine idle
|
|
time. The value must be non-negative.
|
|
Additional information:
|
|
Returns or changes the Energy Star sleep value.
|
|
The device will go into energy saving sleep
|
|
mode after the print engine has been idle for
|
|
the number of seconds specified by this
|
|
object.
|
|
|
|
LaserJet 4050 Series supports values of 0, 900, 1800,
|
|
3600, 7200, and 10800. A value of 0 means
|
|
never go to sleep based on print engine idle
|
|
time. Setting to an unsupported value causes
|
|
the printer to substitute a value (listed
|
|
below) and to return <noError>
|
|
status.
|
|
The values are as follow:
|
|
<=0 snap to 0
|
|
>=1 and <=1349 snap to 900 (15 minutes)
|
|
>=1350 and <=2699 snap to 1800 (30 minutes)
|
|
>=2700 and <=5399 snap to 3600 (1 hour)
|
|
>=5400 and <=8999 snap to 7200 (2 hours)
|
|
>=9000 snap to 10800 (3 hours)"
|
|
::= { settings-system 1 }
|
|
|
|
sleep-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns eTrue if the device is in energy saving sleep
|
|
mode, otherwise returns eFalse. Setting SLEEP-MODE to
|
|
eFalse causes the device to wake up, if it is in sleep
|
|
mode. Setting SLEEP-MODE to eTrue causes the device to
|
|
go into sleep mode.
|
|
Additional information:
|
|
This object returns eTrue if the device is in
|
|
energy saving sleep mode, otherwise it returns eFalse.
|
|
Setting this object to eTrue while the printer
|
|
is awake will not change the printer's current state
|
|
and will return <genErr>
|
|
status. NOTE: This object should behave this way
|
|
when the printer does not have an instant-on fuser.
|
|
Setting this object to eTrue while printer is already
|
|
in Sleep Mode will not change the printer's
|
|
current state and will return <noError> status.
|
|
Setting this object to eFalse while printer is already
|
|
awake will not change the printer's current state and
|
|
will return <noError> status.
|
|
Setting this object to eFalse while the printer is
|
|
asleep causes the device to wake up. "
|
|
::= { settings-system 2 }
|
|
|
|
control-panel-lock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device control panel lock. A value of eDisabled means
|
|
the control panel is unlocked and the device's
|
|
configuration can be modified from the control panel. A
|
|
value of eEnabled means the control panel is locked,
|
|
thus the device's configuration cannot be modified from
|
|
the control panel."
|
|
::= { settings-system 8 }
|
|
|
|
service-password OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set to the password value, other service related
|
|
objects become 'visible' (i.e readable) and/or become
|
|
writable. When written with any other value, the
|
|
service related objects become 'hidden' (i.e. are no
|
|
longer readable) and/or are not longer writable. The
|
|
objects that can be effected by the SERVICE-PASSWORD
|
|
object include: SERIAL-NUMBER and TOTAL-ENGINE-PAGE-
|
|
COUNT. The password value, and the list of objects
|
|
effected by the SERVICE-PASSWORD being set to the
|
|
correct value, should be documented in the device POS.
|
|
Additional information:
|
|
The objects that can be effected by the SERVICE-
|
|
PASSWORD are: SCANNER-JAM-PAGE-COUNT, SCANNER-ADF-PAGE
|
|
-COUNT, SCAN-ADF-PAGE-COUNT, SCANNER-RETRIEVE-SCANLINE,
|
|
SCANNER-MOTOR-CONTROL, COPIER-ADF-PAGE-COUNT, COPIER-
|
|
PRINT-PAGE-COUNT, TOTAL-ENGINE-PAGE-COUNT, PRINT-ENGINE-
|
|
JAM-COUNT, PRINT-ENGINE-MISPICK-COUNT"
|
|
::= { settings-system 9 }
|
|
|
|
|
|
device-cfg-download OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eCfgDownloadIdle(1),
|
|
eCfgDownloadStart(2),
|
|
eCfgDownloadActive(3),
|
|
eCfgDownloadAborted(4),
|
|
eCfgDownloadDone(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Handshaking mechanism between host and device to coordinate the download of device specific data.
|
|
eCfgDownloadIdle - indicates device configuration download activity is not occurring. Device powers up in this state but will otherwise never transition to this state. This state is host settable from eCfgDownloadActive, eCfgDownloadDone, and eCfgDownloadAborted. Host setting to eCfgDownloadIdle while object is in eCfgDownloadActive will cause the download activity to be prematurely terminated. Host setting to this state resets the object to permit another download activity to be initiated.
|
|
eCfgDownloadStart - indicates host wishes to commence a device configuration download activity. This state is only host settable from eCfgDownloadIdle. Only the device can transition this object from this state to eCfgDownloadActive or eCfgDownloadAborted. Device will not set to this state.
|
|
eCfgDownloadActive - indicates download activity is in progress. Device transitions object to this state only from eCfgDownloadStart, to signal data download can commence. The device can transition from this state to eCfgDownloadDone or eCfgDownloadAborted. The host can transition from this state to eCfgDownloadIdle. This state is not host settable.
|
|
eCfgDownloadAborted - indicates the download activity was terminated by the device. Only the device can set to this state from eCfgDownloadStart or eCfgDownloadActive. Only the host can transition from this state to eCfgDownloadIdle. This state is not host settable.
|
|
eCfgDownloadDone - indicates device has completely received the download data. Device transitions to this state only from eCfgDownloadActive. Only the host can transition from this state to eCfgDownloadIdle. This state is not host settable."
|
|
::= { settings-system 11 }
|
|
|
|
|
|
device-cfg-download-data-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eSpeedDials(5),
|
|
eFaxLogs(6),
|
|
eConfigPrams(7),
|
|
eJunkFaxDialStrings(9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of device specific data to be
|
|
downloaded."
|
|
::= { settings-system 12 }
|
|
|
|
|
|
device-cfg-upload OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eCfgUploadIdle(1),
|
|
eCfgUploadStart(2),
|
|
eCfgUploadActive(3),
|
|
eCfgUploadAborted(4),
|
|
eCfgUploadDone(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Handshaking mechanism between host and device to
|
|
coordinate the upload of device specific data.
|
|
eCfgUploadIdle - indicates device configuration upload
|
|
activity is not occurring. Device powers up in this
|
|
state but will otherwise never transition to this state.
|
|
This state is host settable from eCfgUploadActive,
|
|
eCfgUploadDone, and eCfgUploadAborted. Host setting to
|
|
eCfgUploadIdle while object is in eCfgUploadActive will
|
|
cause the upload activity to be prematurely terminated.
|
|
Host setting to this state resets the object allowing a
|
|
new upload to be initiated.
|
|
eCfgUploadStart - indicates host wishes to commence a
|
|
device configuration upload activity. This state is
|
|
only host settable from eCfgUploadIdle. Only the device
|
|
can transition this object from this state to
|
|
eCfgUploadActive or eCfgUploadAborted. Device will not
|
|
set to this state.
|
|
eCfgUploadActive - indicates upload activity is in
|
|
progress. Device transitions object to this state only
|
|
from eCfgUploadStart, to signal data upload can
|
|
commence. The device can transition from this state to
|
|
eCfgUploadDone or eCfgUploadAborted. The host can
|
|
transition from this state to eCfgUploadIdle. This
|
|
state is not host settable.
|
|
eCfgUploadAborted - indicates the upload activity was
|
|
terminated by the device. Only the device can set to
|
|
this state from eCfgUploadStart or eCfgUploadActive.
|
|
Only the host can transition from this state to
|
|
eCfgUploadIdle. This state is not host settable.
|
|
eCfgUploadDone - indicates device completely
|
|
transmitted the upload data. Device transitions to this
|
|
state only from eCfgUploadActive. Only the host can
|
|
transition from this state to eCfgUploadIdle. This
|
|
state is not host settable."
|
|
::= { settings-system 13 }
|
|
|
|
|
|
device-cfg-upload-data-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eSpeedDials(5),
|
|
eFaxLogs(6),
|
|
eConfigPrams(7),
|
|
eJunkFaxDialStrings(9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of device specific data to be
|
|
uploaded."
|
|
::= { settings-system 14 }
|
|
|
|
|
|
download-timeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of seconds that device will wait
|
|
for data from the host before the device determines the
|
|
host is being unresponsive. This timeout condition may
|
|
cause the device to take recourse action regarding the
|
|
disposition of the download activity. A value of zero
|
|
indicates device will wait forever for the host data.
|
|
POS should indicate whether this object value, when set
|
|
by the host, is remembered between device power cycles.
|
|
Additional information:
|
|
This object is volatile and as such will not be
|
|
retained by the device between power cycles."
|
|
::= { settings-system 17 }
|
|
|
|
|
|
upload-timeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of seconds that device will wait
|
|
for response from the host after transmitting a unit of
|
|
data before the device determines the host is being
|
|
unresponsive. This timeout condition may cause the
|
|
device to take recourse action regarding the disposition
|
|
of the upload activity. A value of zero indicates
|
|
device will wait forever for the host response. POS
|
|
should indicate whether this object value, when set by
|
|
the host, is remembered between device power cycles
|
|
Additional information:
|
|
This object is volatile and as such will not be
|
|
retained by the device between power cycles."
|
|
::= { settings-system 18 }
|
|
|
|
|
|
run-location OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or changes the location from which code
|
|
executes. The object allows the user to pick a memory
|
|
bank to run code from which is different than the
|
|
default running code bank. A value of 0 means the code
|
|
executes from the default code bank, which should be
|
|
documented in the device POS. The list of supported
|
|
values should be documented in the device POS. Setting
|
|
to an unsupported value causes the device to return
|
|
<badValue>.
|
|
Additional information:
|
|
Returns or changes the location from which code
|
|
should be run. The object allows the user to pick a ram bank
|
|
to run code from which is potentially faster than the onboard
|
|
ROM. LaserJet 8100 Series and LaserJet 8000 Series support values of 0,4-9. A value of 0
|
|
means run code from default ROM device. Values other than 0
|
|
indicate a valid RAM bank of size >= 8MBs. Setting to an
|
|
unsupported value causes the printer to leave the run location
|
|
set to its previous value."
|
|
::= { settings-system 21 }
|
|
|
|
date-display OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDateDisplayMMDDYY(1),
|
|
eDateDisplayDDMMYY(2),
|
|
eDateDisplayYYMMDD(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls front-panel date display format."
|
|
::= { settings-system 22 }
|
|
|
|
|
|
device-cfg-param-command OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A C structure containing the following fields:
|
|
typedef struct {
|
|
u8bit list_id;
|
|
s8bit auto_incr;
|
|
u16bit max_index;
|
|
u16bit rec_size;
|
|
u16bit index;
|
|
u8bit data[];
|
|
} PML_device_cfg_param_cmd_t;
|
|
where u8bit is an unsigned byte (0..255), s8bit is a
|
|
signed byte (-128..127), and u16bit is an big endian
|
|
format unsigned short (0..65535). The POS should state
|
|
which list_id's the device supports.
|
|
Additional information:
|
|
HP Laserjet 3200 supports two values for list_id:
|
|
0 for configuration parameters and
|
|
1 for default configuration parameters."
|
|
::= { settings-system 23 }
|
|
|
|
|
|
copier-token OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides an advisory locking mechanism for hosts to coordinate
|
|
exclusive access to a copier device. Setting the object to a
|
|
unique id will only succeed if the token is currently set to 0.
|
|
The token is unlocked when it is set to 0. If the token is set
|
|
to a any value other than 0, then token is locked. If the token
|
|
was set to a unique id (locked), then an attempt to set (lock)
|
|
the token will fail. If the token was set to 0 (unlocked), then
|
|
an attempt to set (lock) the token will succeed in locking the
|
|
token. A get operation on COPIER-TOKEN will return its current
|
|
setting. The device does not prevent access to any objects. It
|
|
is assumed that hosts will be well behaved; respecting this
|
|
advisory locking mechanism by:
|
|
1) acquiring the lock before changing copier objects, and
|
|
2) releasing the lock when done changing copier objects.
|
|
Additional information:
|
|
Provides an advisory locking mechanism for hosts to
|
|
coordinate exclusive access. Setting the object to a unique id
|
|
will only succeed if the token is currently set to 0. The token
|
|
is unlocked when it is set to 0. If the token is set to a any
|
|
value other than 0, then token is locked.
|
|
|
|
If the token was set to a unique id (locked), then an
|
|
attempt to set (lock) the token will fail.
|
|
|
|
If the token was set to 0 (unlocked), then an attempt to set (lock)
|
|
the token will succeed in locking the token.
|
|
|
|
A get operation on COPY-TOKEN will return its current setting.
|
|
The device does not prevent access to any objects. It is assumed
|
|
that hosts will be well behaved; respecting this advisory locking
|
|
mechanism by:
|
|
1) acquiring the lock before changing copy objects, and
|
|
2) releasing the lock when done changing copy objects."
|
|
::= { settings-system 24 }
|
|
|
|
|
|
fax-upload-token OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides an advisory locking mechanism for hosts to coordinate
|
|
exclusive access to the fax upload features of a device. Setting
|
|
the object to a unique id will only succeed if the token is
|
|
currently set to 0. The token is unlocked when it is set to 0.
|
|
If the token is set to a any value other than 0, then token is
|
|
locked. If the token was set to a unique id (locked), then an
|
|
attempt to set (lock) the token will fail. If the token was set
|
|
to 0 (unlocked), then an attempt to set (lock) the token will
|
|
succeed in locking the token. A get operation on FAX-UPLOAD-TOKEN
|
|
will return its current setting. The device does not prevent
|
|
MAX-ACCESS to any objects. It is assumed that hosts will be well behaved;
|
|
respecting this advisory locking mechanism by:
|
|
1) acquiring the lock before changing any fax-upload objects, and
|
|
2) releasing the lock when done changing scan objects.
|
|
Additional information:
|
|
Provides an advisory locking mechanism for hosts to
|
|
coordinate exclusive access. Setting the object to a unique id
|
|
will only succeed if the token is currently set to 0. The token
|
|
is unlocked when it is set to 0. If the token is set to a any
|
|
value other than 0, then token is locked.
|
|
|
|
If the token was set to a unique id (locked), then an
|
|
attempt to set (lock) the token will fail.
|
|
|
|
If the token was set to 0 (unlocked), then an attempt to set (lock)
|
|
the token will succeed in locking the token.
|
|
|
|
A get operation on FAX-UPLOAD-TOKEN will return its current setting.
|
|
The device does not prevent access to any objects. It is assumed
|
|
that hosts will be well behaved; respecting this advisory locking
|
|
mechanism by:
|
|
1) acquiring the lock before changing fax objects, and
|
|
2) releasing the lock when done changing fax objects."
|
|
::= { settings-system 26 }
|
|
|
|
|
|
fax-download-token OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides an advisory locking mechanism for hosts to coordinate
|
|
exclusive access to the fax download features of a device. Setting
|
|
the object to a unique id will only succeed if the token is
|
|
currently set to 0. The token is unlocked when it is set to 0.
|
|
If the token is set to a any value other than 0, then token is
|
|
locked. If the token was set to a unique id (locked), then an
|
|
attempt to set (lock) the token will fail. If the token was set
|
|
to 0 (unlocked), then an attempt to set (lock) the token will
|
|
succeed in locking the token. A get operation on FAX-DOWNLOAD-TOKEN
|
|
will return its current setting. The device does not prevent
|
|
MAX-ACCESS to any objects. It is assumed that hosts will be well behaved;
|
|
respecting this advisory locking mechanism by:
|
|
1) acquiring the lock before changing any fax-download objects, and
|
|
2) releasing the lock when done changing scan objects.
|
|
Additional information:
|
|
Provides an advisory locking mechanism for hosts to
|
|
coordinate exclusive access. Setting the object to a unique id
|
|
will only succeed if the token is currently set to 0. The token
|
|
is unlocked when it is set to 0. If the token is set to a any
|
|
value other than 0, then token is locked.
|
|
|
|
If the token was set to a unique id (locked), then an
|
|
attempt to set (lock) the token will fail.
|
|
|
|
If the token was set to 0 (unlocked), then an attempt to set (lock)
|
|
the token will succeed in locking the token.
|
|
|
|
A get operation on FAX-DOWNLOAD-TOKEN will return its current setting.
|
|
The device does not prevent access to any objects. It is assumed
|
|
that hosts will be well behaved; respecting this advisory locking
|
|
mechanism by:
|
|
1) acquiring the lock before changing fax objects, and
|
|
2) releasing the lock when done changing fax objects."
|
|
::= { settings-system 27 }
|
|
|
|
device-config-token OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides an advisory locking mechanism for hosts to coordinate
|
|
exclusive access to a specific device or subset of device
|
|
capabilities. Setting the object to a unique id will only succeed
|
|
if the token is currently set to 0. The token is unlocked when it
|
|
is set to 0. If the token is set to a any value other than 0, then
|
|
token is locked. If the token was set to a unique id (locked),
|
|
then an attempt to set (lock) the token will fail. If the token
|
|
was set to 0 (unlocked), then an attempt to set (lock) the token
|
|
will succeed in locking the token. A get operation on
|
|
DEVICE-CONFIG-TOKEN will return its current setting. The device
|
|
does not prevent access to any objects. It is assumed that hosts
|
|
will be well behaved; respecting this advisory locking mechanism by:
|
|
1) acquiring the lock before changing device config objects, and
|
|
2) releasing the lock when done changing device config objects.
|
|
Additional information:
|
|
Provides an advisory locking mechanism for hosts to
|
|
coordinate exclusive access. Setting the object to a unique id
|
|
will only succeed if the token is currently set to 0. The token
|
|
is unlocked when it is set to 0. If the token is set to a any
|
|
value other than 0, then token is locked.
|
|
|
|
If the token was set to a unique id (locked), then an
|
|
attempt to set (lock) the token will fail.
|
|
|
|
If the token was set to 0 (unlocked), then an attempt to set (lock)
|
|
the token will succeed in locking the token.
|
|
|
|
A get operation on CONFIG-TOKEN will return its current setting.
|
|
The device does not prevent access to any objects. It is assumed
|
|
that hosts will be well behaved; respecting this advisory locking
|
|
mechanism by:
|
|
1) acquiring the lock before changing CONFIG objects, and
|
|
2) releasing the lock when done changing CONFIG objects."
|
|
::= { settings-system 28 }
|
|
|
|
|
|
mono-color-switching-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNeverSwitch(1),
|
|
eAlwaysSwitch(2),
|
|
eLookAheadSwitch(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object allows the user to view/change the color/mono
|
|
switching mode for a device.
|
|
Additional information:
|
|
This object allows the user to view/change the color/mono
|
|
switching mode for a device."
|
|
::= { settings-system 31 }
|
|
|
|
|
|
control-panel-button-press-delay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object gives the number of seconds to wait before
|
|
simulating the button press when CONTROL-PANEL-BUTTON-PRESS is
|
|
next called.
|
|
Additional information:
|
|
This object gives the number of seconds to wait before
|
|
simulating the button press when CONTROL-PANEL-BUTTON-PRESS is
|
|
next called."
|
|
::= { settings-system 47 }
|
|
|
|
|
|
low-power OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Returns or changes the Auto Low Power sleep value. The device
|
|
will go into energy saving Auto Low Power mode after the print
|
|
engine has been idle for the number of seconds specified by
|
|
this object. Frida supports values of 300 until 14400 seconds.
|
|
If the value is invalid then it will return status of
|
|
PML_Status_ErrUnsupValue and will not issue command to the
|
|
engine.
|
|
Additional information:
|
|
Returns or changes the Auto Low Power sleep value. The device
|
|
will go into energy saving Auto Low Power mode after the print
|
|
engine has been idle for the number of seconds specified by
|
|
this object. The product supports values of 0 (Off), 60 (1
|
|
minute), 900 (15 minutes), 1800 (30 minutes), 3600 (1 hour),
|
|
and 7200 (2 hours).
|
|
If the value is invalid then it will return a status of
|
|
PML_ERROR_INVALID_OR_UNSUPPORTED_VALUE and will not issue
|
|
a command to the engine."
|
|
::= { settings-system 49 }
|
|
|
|
|
|
fuser-pressure-release OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisengage(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object is used to disengage the pressure on the fuser to
|
|
prevent roller marks on the fuser, which can occur when the
|
|
pressure is engaged for long periods of time.
|
|
Additional information:
|
|
This object is used to disengage the pressure on the
|
|
fuser to prevent roller marks on the fuser, which can occur when
|
|
the pressure is engaged for long periods of time."
|
|
::= { settings-system 53 }
|
|
|
|
|
|
control-panel-display-contrast OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eLightest(1),
|
|
eLight(2),
|
|
eMedium(3),
|
|
eDark(4),
|
|
eDarkest(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object returns or sets the display contrast setting if the
|
|
control panel has a display and it supports contrast
|
|
adjustment. The setting Is stored in NVRAM, so the value is
|
|
saved over power cycles.
|
|
Additional information:
|
|
This object returns or sets the display contrast setting
|
|
if the control panel has a display and it supports
|
|
contrast adjustment. The setting is stored in NVRAM,
|
|
so the value is saved over power cycles."
|
|
::= { settings-system 73 }
|
|
|
|
calibration-lowspeed-enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisable(1),
|
|
eEnable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable or disable an optional low speed calibration. This
|
|
calibration will allow the device to obtain accurate data for
|
|
use with low speed print modes.
|
|
Additional information:
|
|
Enable or disable an optional low speed calibration. This
|
|
calibration will allow the device to obtain accurate data for
|
|
use with low speed print modes."
|
|
::= { settings-system 85 }
|
|
|
|
|
|
start-engine-early-warmup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eValue1(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This PML object is used by HP SW drivers to signal the printer
|
|
that a job is coming, and to start the warm-up process
|
|
early.The effect of warming up early will reduce the First Page
|
|
Out time.
|
|
Additional information:
|
|
This PML object is used by HP SW drivers to signal the printer
|
|
that a job is coming, and to start the warm-up process
|
|
early.The effect of warming up early will reduce the First Page
|
|
Out time."
|
|
::= { settings-system 99 }
|
|
|
|
|
|
enable-engine-early-warmup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisable(1),
|
|
eEnable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This PML object is used by HP SW to enable/disable the printer
|
|
to send the signal of warm-up process early to engine. The
|
|
effect of warming up early will reduce the First Page Out
|
|
time.
|
|
Additional information:
|
|
This PML object is used by HP SW to enable/disable the printer
|
|
to send the signal of warm-up process early to engine. The
|
|
effect of warming up early will reduce the First Page Out
|
|
time."
|
|
::= { settings-system 101 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.1
|
|
toner-miser-plus-value OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object is used to enable/disable toner miser plus
|
|
feature"
|
|
::= { settings-system2 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.2
|
|
toner-miser-plus-supported OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " The supported values are ON and OFF. The toner miser plus
|
|
feature is turned OFF by default"
|
|
::= { settings-system2 2 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.17
|
|
protect-ews-info-tab OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This PML object is used by the WJA tool to allow administrators
|
|
to enable or disable EWS information tab protection. When this
|
|
option in selected/turned on the user will not be able to
|
|
MAX-ACCESS anything on the EWS without logging in with the EWS
|
|
device <<hidden>>(in case the EWS device <<hidden>> is configured).
|
|
If the option is turned off the user will be able to access the
|
|
information tab on the EWS page without providing the EWS
|
|
device <<hidden>>(in case the EWS device <<hidden>> is configured),
|
|
for all other tabs on the EWS page the user will have to login with EWS device <<hidden>>"
|
|
::= { settings-system2 17 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.19
|
|
eprint-opt-in OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object is the master switch for the ePrint feature. By
|
|
default this should be eOff(1). This differs from
|
|
EPRINT-ENABLED in that ePrint connot be registered with the
|
|
cloud when this is diabled while EPRINT-ENABLED allows
|
|
registration and temporary disablement"
|
|
::= { settings-system2 19 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.20
|
|
eprint-enabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Returns the current setting of the ePrint feature"
|
|
::= { settings-system2 20 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.21
|
|
eprint-email-address OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This is the configured ePrint email address"
|
|
::= { settings-system2 21 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.22
|
|
eprint-email OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object reports the current setting of ePrint e-mail"
|
|
::= { settings-system2 22 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.23
|
|
eprint-printer-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This is the configured ePrint printer code"
|
|
::= { settings-system2 23 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.24
|
|
eprint-hp-web-services OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object reports the current setting of the ePrint web
|
|
services"
|
|
::= { settings-system2 24 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.25
|
|
eprint-jdi-interface OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eJDIInterface1(1),
|
|
eJDIInterface2(2),
|
|
eJDIInterface3(3),
|
|
eJDIInterface4(4),
|
|
eJDIInterface5(5),
|
|
eJDIInterface6(6),
|
|
eJDIInterface7(7),
|
|
eJDIInterface8(8),
|
|
eJDIInterface9(9),
|
|
eJDIInterface10(10)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This number represents the instance of jdi that has ePrint
|
|
registered"
|
|
::= { settings-system2 25 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.31
|
|
eprint-supported OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object is used to indicate whether the device supports
|
|
ePrint or not. By default this should be eOff(1), but will be
|
|
set to eOn(2) if the device supports ePrint"
|
|
::= { settings-system2 31 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.32
|
|
eprint-supported-jdi OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object is used to indicate whether the JDI supports ePrint
|
|
or not. By default this should be eOff(1), but will be set to
|
|
eOn(2) if JDI supports ePrint"
|
|
::= { settings-system2 32 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.47
|
|
fax-init-at-command OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This custom fax modem commands will be executed on the modem
|
|
every time a fax modem is initialized along with the predefined
|
|
set of commands
|
|
"
|
|
::= { settings-system2 47 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.59
|
|
set-primary-interface-index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Sets the index of the primary network interface to be used for outbound routing. Index 1 is EIO, 2 is wireless station, 3 is wireless access point and 4 is JDI."
|
|
::= { settings-system2 59 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.25.60
|
|
wireless-direct-print-setting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enable or disable wireless direct printing."
|
|
::= { settings-system2 60 }
|
|
|
|
copy-scanner-dimensions OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object is used to obtain the exact pixel scan dimensions
|
|
for copy. The dimensions returned correspond to the quality,
|
|
reduce/enlarge, and media size currently selected.
|
|
Additional information:
|
|
This object is used to obtain the exact pixel scan dimensions for copy.
|
|
The dimensions returned correspond to the quality, reduce/enlarge,
|
|
and media size currently selected."
|
|
::= { status-scanner 13 }
|
|
|
|
|
|
device-configure-generic-language-prompt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object is used to determine whether to prompt the user to
|
|
enter the appropriate language.
|
|
Additional information:
|
|
This object is used to determine whether to
|
|
prompt the user to enter the appropriate language
|
|
at boot."
|
|
::= { device-configure 10 }
|
|
|
|
|
|
device-configure-generic-country-prompt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " This object is used to determine whether to prompt the user to
|
|
enter the appropriate country at boot.
|
|
Additional information:
|
|
This object is used to determine whether to
|
|
prompt the user to enter the appropriate country
|
|
at boot."
|
|
::= { device-configure 11 }
|
|
|
|
|
|
device-configure-generic-country OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eKorea(4),
|
|
eIndonesia(5),
|
|
eChina(6),
|
|
eTaiwan(7),
|
|
ePhilippines(8),
|
|
eThailand(9),
|
|
eSriLanka(10),
|
|
eBrazil(12),
|
|
eCanada(13),
|
|
eMexico(14),
|
|
eUnitedStates(15),
|
|
eArgentina(16),
|
|
eChile(17),
|
|
eNewZealand(19),
|
|
eIsrael(21),
|
|
eAustralia(23),
|
|
eIndia(25),
|
|
ePakistan(26),
|
|
eMalaysia(27),
|
|
eHongKong(29),
|
|
eSingapore(30),
|
|
eUnitedKingdom(31),
|
|
eAustria(34),
|
|
eNetherlands(35),
|
|
eGermany(39),
|
|
eDenmark(40),
|
|
eSweden(41),
|
|
eSouthAfrica(42),
|
|
eNorway(43),
|
|
eIreland(44),
|
|
eBelgium(45),
|
|
eFinland(46),
|
|
eFrance(47),
|
|
eTurkey(48),
|
|
eGreece(49),
|
|
ePortugal(50),
|
|
eItaly(51),
|
|
eSpain(55),
|
|
ePoland(56),
|
|
eBulgaria(57),
|
|
eCroatia(58),
|
|
eRomania(59),
|
|
eSlovakRepublic(60),
|
|
eCzechRepublic(61),
|
|
eHungary(62),
|
|
eRussia(64),
|
|
ePeru(70),
|
|
eJordan(78),
|
|
eLebanon(79),
|
|
eSwitzerland(82),
|
|
eVietnam(83),
|
|
eLuxemberg(85),
|
|
eNorthAfrica(86),
|
|
eBelarus(66),
|
|
eBrunei(33),
|
|
eCambodia(94),
|
|
eCyprus(95),
|
|
eEgypt(67),
|
|
eEstonia(54),
|
|
eIceland(96),
|
|
eLatvia(53),
|
|
eLiechtentstein(98),
|
|
eLithuania(52),
|
|
eMalta(99),
|
|
eMorocco(65),
|
|
eSaudiArabia(28),
|
|
eTunisia(32),
|
|
eUAE(88),
|
|
eUkraine(63)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the location configuration for the device. This affects
|
|
parameters that vary per region like the default paper size,
|
|
symbol set, supply reorder URL, and fax parameters if
|
|
applicable."
|
|
::= { device-configure 16 }
|
|
|
|
|
|
device-configure-secure-nvram-items OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object is used to configure product settings that are
|
|
stored in secure area of nvram. The object consists of a 16-bit
|
|
variable in secure nvram. Bits 15-8 are product specific. Bits
|
|
7-0 are system specific.
|
|
Additional information:
|
|
This object is used to configure product settings that are
|
|
stored in secure area of nvram. The object consists of a 16-bit
|
|
variable in secure nvram. Bits 15-8 are product specific. Bits
|
|
7-0 are system specific."
|
|
::= { device-configure 17 }
|
|
|
|
|
|
device-configure-cpe-feature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object allows CPE to enable specific bug fixes or
|
|
enhancements in post-release products.
|
|
Additional information:
|
|
This object allows CPE to enable specific bug fixes or
|
|
enhancements in post-release products."
|
|
::= { device-configure 18 }
|
|
|
|
|
|
device-configure-custom-product-number OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object allows manufacturing to change the product number
|
|
to a pre-defined alternate after release. This feature will
|
|
allow manufacturing to assign unique product numbers to custom
|
|
product bundles when the device is unable to determine its
|
|
product number in firmware. For example, A HP Color LaserJet
|
|
CP1515n could be configured to display CP1516n to the customer.
|
|
This product number must be defined prior to release.
|
|
Additional information:
|
|
This object allows manufacturing to change the product number
|
|
to a pre-defined alternate after release. This feature will
|
|
allow manufacturing to assign unique product numbers to custom
|
|
product bundles when the device is unable to determine its
|
|
product number in firmware. For example, A HP Color LaserJet
|
|
CP1515n could be configured to display CP1516n to the customer.
|
|
This product number must be defined prior to release."
|
|
::= { device-configure 19 }
|
|
|
|
|
|
device-configure-preferred-boot-localization-language OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEnglish(1),
|
|
eFrench(2),
|
|
eGerman(3),
|
|
eSpanish(4),
|
|
eItalian(5),
|
|
eSwedish(6),
|
|
eDanish(7),
|
|
eNorwegian(8),
|
|
eDutch(9),
|
|
eFinnish(10),
|
|
ePortuguese(12),
|
|
ePolish(13),
|
|
eTurkish(14),
|
|
eTradChinese(16),
|
|
eSimpChinese(17),
|
|
eRussian(18),
|
|
eCzech(19),
|
|
eHungarian(20),
|
|
eKorean(21),
|
|
eThai(22),
|
|
eUnknownLanguage(44)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Preferred localization language used by the device at boot up
|
|
time. Setting this object will instruct the device to boot up
|
|
in that language. Setting this language does not impact device
|
|
generated PML strings, control panel messages, and text
|
|
contained in any of the printer generated printed pages. The
|
|
order of these languages is the same order that is defined for
|
|
LOCALIZATION-LANGUAGE.
|
|
Additional information:
|
|
Preferred localization language used by the device at
|
|
boot up time. Setting this object will instruct the device to boot
|
|
up in that language. This will allow the device to NOT show the
|
|
generic prompt on the CP display, since the device already knows
|
|
the language."
|
|
::= { device-configure 20 }
|
|
|
|
|
|
date-and-time OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A C structure containing the following fields: typedef
|
|
struct {
|
|
ubyte yr; /* year: 0 to 99 */
|
|
ubyte mon; /* month: 1 to 12 */
|
|
ubyte day; /* day: 1 to 31 */
|
|
ubyte wday; /* Day of week: 1 to 07 */
|
|
ubyte hr; /* hour: 0 to 23 */
|
|
ubyte min; /* minute: 0 to 59 */
|
|
ubyte sec; /* second: 0 to 59 */
|
|
} date_t;
|
|
where ubyte is an unsigned byte (0-255)."
|
|
::= { status-system 17 }
|
|
|
|
|
|
time-display OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTimeDisplayTwelveHour(1),
|
|
eTimeDisplayTwentyFourHour(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls front-panel time display format. Set to
|
|
eTimeDisplayTwelveHour for AM/PM display. Set to
|
|
eTimeDisplayTwentyFourHour for military-type display."
|
|
::= { status-system 28 }
|
|
|
|
|
|
device-cfg-download-error OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Error status of the configuration download session. POS should
|
|
indicate the actual error values reserving value 0 as NO
|
|
ERROR.
|
|
Additional information:
|
|
A value of 0 indicates NO ERROR."
|
|
::= { status-system 43 }
|
|
|
|
|
|
device-cfg-upload-error OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Error status of the configuration upload session. POS should
|
|
indicate the actual error values reserving value 0 as NO
|
|
ERROR.
|
|
Additional information:
|
|
A value of 0 indicates NO ERROR."
|
|
::= { status-system 45 }
|
|
|
|
|
|
ship-cartridge-installed-in-printer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set developer motor cams in the position needed for shipping
|
|
the cartridges installed in the printer if set to eTrue.
|
|
Additional information:
|
|
Notifies the engine that it needs to change it's shipping state."
|
|
::= { status-system 97 }
|
|
|
|
|
|
device-mac-address OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The device's MAC address.
|
|
Additional information:
|
|
The device's MAC address."
|
|
::= { status-system 120 }
|
|
|
|
|
|
extended-print-modes-modified OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eYes(1),
|
|
eNo(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object allows the user to view whether the extended print
|
|
modes have been modified from their default settings.
|
|
Additional information:
|
|
This object allows the user to view whether the extended print
|
|
modes have been modified from their default settings."
|
|
::= { status-system 121 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.23.1.1
|
|
supports-pjl-user-groups OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Returns eTrue if the device is able to process PJL user group
|
|
variables. See the PJL Technical Reference for the proper
|
|
syntax for setting these variables. Because there may be many
|
|
user groups in some environments, this object allows a client
|
|
application to optimize the print job by including user groups
|
|
only when the device is able to process them"
|
|
::= { settings-security 1 }
|
|
|
|
|
|
simm1-bank1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eFlashMemory(7),
|
|
eSDRandomAccessMemory(14),
|
|
eSRandomAccessMemory(15),
|
|
eFPMRandomAccessMemory(16),
|
|
eEDORandomAccessMemory(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
Bank 1 of SIMM slot 1. See SIMM1-TYPE for a
|
|
description.
|
|
Additional information:
|
|
This object is used for describing the type
|
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
|
::= { simm1-bank1 1 }
|
|
|
|
|
|
simm1-bank1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of Bank 1 of the
|
|
SIMM installed in SIMM slot 1. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed bank option in bytes. This object is not
|
|
supported unless the SIMM1-BANK1-TYPE type is
|
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
|
or eFPMRandomAccessMemory."
|
|
::= { simm1-bank1 2 }
|
|
|
|
|
|
simm1-bank2-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eFlashMemory(7),
|
|
eSDRandomAccessMemory(14),
|
|
eSRandomAccessMemory(15),
|
|
eFPMRandomAccessMemory(16),
|
|
eEDORandomAccessMemory(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
Bank 2 of SIMM slot 1. See SIMM1-TYPE for a
|
|
description.
|
|
Additional information:
|
|
This object is used for describing the type
|
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
|
::= { simm1-bank2 1 }
|
|
|
|
|
|
simm1-bank2-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of Bank 2 of the
|
|
SIMM installed in SIMM slot 1. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed bank option in bytes. This object is not
|
|
supported unless the SIMM1-BANK2-TYPE type is
|
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
|
or eFPMRandomAccessMemory."
|
|
::= { simm1-bank2 2 }
|
|
|
|
|
|
simm2-bank1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eFlashMemory(7),
|
|
eSDRandomAccessMemory(14),
|
|
eSRandomAccessMemory(15),
|
|
eFPMRandomAccessMemory(16),
|
|
eEDORandomAccessMemory(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
Bank 1 of SIMM slot 2. See SIMM1-TYPE for a
|
|
description.
|
|
Additional information:
|
|
This object is used for describing the type
|
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
|
::= { simm2-bank1 1 }
|
|
|
|
|
|
simm2-bank1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of Bank 1 of the
|
|
SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed bank option in bytes. This object is not
|
|
supported unless the SIMM2-BANK1-TYPE type is
|
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
|
or eFPMRandomAccessMemory."
|
|
::= { simm2-bank1 2 }
|
|
|
|
|
|
simm2-bank2-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eFlashMemory(7),
|
|
eSDRandomAccessMemory(14),
|
|
eSRandomAccessMemory(15),
|
|
eFPMRandomAccessMemory(16),
|
|
eEDORandomAccessMemory(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
Bank 2 of SIMM slot 2. See SIMM1-TYPE for a
|
|
description.
|
|
Additional information:
|
|
This object is used for describing the type
|
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
|
::= { simm2-bank2 1 }
|
|
|
|
|
|
simm2-bank2-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of Bank 2 of the
|
|
SIMM installed in SIMM slot 2. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed bank option in bytes. This object is not
|
|
supported unless the SIMM2-BANK2-TYPE type is
|
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
|
or eFPMRandomAccessMemory."
|
|
::= { simm2-bank2 2 }
|
|
|
|
|
|
simm3-bank1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eFlashMemory(7),
|
|
eSDRandomAccessMemory(14),
|
|
eSRandomAccessMemory(15),
|
|
eFPMRandomAccessMemory(16),
|
|
eEDORandomAccessMemory(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
Bank 1 of SIMM slot 3. See SIMM1-TYPE for a
|
|
description.
|
|
Additional information:
|
|
This object is used for describing the type
|
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
|
::= { simm3-bank1 1 }
|
|
|
|
|
|
simm3-bank1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of Bank 1 of the
|
|
SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed bank option in bytes. This object is not
|
|
supported unless the SIMM3-BANK1-TYPE type is
|
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
|
or eFPMRandomAccessMemory."
|
|
::= { simm3-bank1 2 }
|
|
|
|
|
|
simm3-bank2-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eFlashMemory(7),
|
|
eSDRandomAccessMemory(14),
|
|
eSRandomAccessMemory(15),
|
|
eFPMRandomAccessMemory(16),
|
|
eEDORandomAccessMemory(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
Bank 2 of SIMM slot 3. See SIMM1-TYPE for a
|
|
description.
|
|
Additional information:
|
|
This object is used for describing the type
|
|
of DIMM banks. Each physical DIMM slot has up to 2 banks."
|
|
::= { simm3-bank2 1 }
|
|
|
|
|
|
simm3-bank2-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of Bank 2 of the
|
|
SIMM installed in SIMM slot 3. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed bank option in bytes. This object is not
|
|
supported unless the SIMM3-BANK2-TYPE type is
|
|
eReadOnlyMemory, eFlashMemory, eEDORandomAccessMemory,
|
|
eSDRandomAccessMemory, eSRandomAccessMemory,
|
|
or eFPMRandomAccessMemory."
|
|
::= { simm3-bank2 2 }
|
|
|
|
|
|
ram-disk-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2),
|
|
eAuto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or controls RAM disk support. eOFF turns off
|
|
the RAM disk functionality. eOn turns on the RAM disk
|
|
functionality and creates a RAM disk whose size is
|
|
controlled by the RAM-DISK-SIZE object. eAuto turns on
|
|
the RAM disk functionality and creates a RAM disk size
|
|
determined by the printer based on installed options and
|
|
other memory related settings.
|
|
Additional information:
|
|
Returns or controls RAM disk support. eOFF turns off
|
|
the RAM disk functionality. eOn turns on the RAM disk
|
|
functionality and creates a RAM disk whose size is
|
|
controlled by the RAM-DISK-SIZE object. eAuto turns on
|
|
the RAM disk functionality and creates a RAM disk size
|
|
determined by the printer based on the amount of installed
|
|
memory. The automatic size will be 25 percent of all memory
|
|
above 4MB."
|
|
::= { settings-mass-storage-bd 1 }
|
|
|
|
|
|
ram-disk-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or controls the size of the RAM disk. The
|
|
device POS specifies the minimum memory requirements.
|
|
The object MAXIMUM-RAM-DISK-MEMORY specifies the maximum
|
|
memory available for the RAM disk.
|
|
Additional information:
|
|
Returns or controls the size of the RAM disk. The values
|
|
that can be set depend on the current setting of the
|
|
RAM-DISK-MODE object, and the amount of memory available
|
|
above 4MB. Use the MAXIMUM-RAM-DISK-MEMORY object to
|
|
determine the amount of additional memory available
|
|
for the RAM disk."
|
|
::= { settings-mass-storage-bd 2 }
|
|
|
|
|
|
maximum-ram-disk-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object's name is misleading. This object does not
|
|
return the maximum configurable RAM disk size. Instead,
|
|
it returns the maximum amount of memory, in bytes, that
|
|
can used to increase the size of the RAM disk.
|
|
Additional information:
|
|
This object returns the maximum amount of additional
|
|
memory that is available for increasing the size of the RAM
|
|
disk."
|
|
::= { status-mass-storage-bd 1 }
|
|
|
|
|
|
device-configure-print-engine-speed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNormal(1),
|
|
eSlowDown1(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return or set the value of the print engine speed. Where
|
|
eNormal is the default speed and with each eSlowDownN setting
|
|
the printer gets progressively slower than the previous speed.
|
|
Additional information:
|
|
This object will only be registered once the
|
|
PE_TEST_PASSWORD is set. This object is used to
|
|
return or set the value for the engine's print speed.
|
|
This value is written to NVRAM and is persistant.
|
|
eNormal = Normal engine speed.
|
|
eSlowDown1 = Decreased engine speed."
|
|
::= { device-configure 5 }
|
|
|
|
|
|
device-configure-duplexer-enabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eDisabled(1),
|
|
eEnabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return or set the value for the duplexer installed. eEnabled =
|
|
The duplexer is installed. eDisabled = The duplexer is not
|
|
installed.
|
|
Additional information:
|
|
This object will only be registered once the
|
|
PE_TEST_PASSWORD is set. This object is used to
|
|
return or set the value controlling the duplexer
|
|
This value is written to NVRAM and is persistant.
|
|
eDisabled = Disabled Duplexer.
|
|
eEnabled = Enabled Duplexer."
|
|
::= { device-configure 8 }
|
|
|
|
|
|
disk-storage-block-driver2-test-return-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test object will not be supported in any released
|
|
product. Setting this object allows the next call to
|
|
the mass storage block driver 2 to return the specified
|
|
code. The POS will specify the binary format.
|
|
Additional information:
|
|
The hrDeviceIndex value for the mass storage
|
|
device is the same value that is used to index into the
|
|
DISK-STORAGE-BLOCK-DRIVERS sub-tree. Since this product
|
|
only supports one mass storage device, the hrDeviceIndex
|
|
for the mass storage device will be 2 if the mass storage device is
|
|
installed. The value is a two byte value. The value
|
|
of the first byte indicates the return code, as described
|
|
in the following table:
|
|
value | meaning
|
|
------+------------------
|
|
1 | After the next power cycle, indicate the
|
|
| mass storage device is not installed. Only affects the
|
|
| printer state after the next power cycle.
|
|
2 | After the next power cycle, indicate the
|
|
| mass storage device is not initialized. Changes the
|
|
| contents of the mass storage device so the mass storage device becomes
|
|
| uninitialized.
|
|
3 | After the next power cycle, indicate the
|
|
| mass storage device is defective. Only affects the
|
|
| printer state after the next power cycle.
|
|
4 | Cause the specified call to the read block
|
|
| routine to indicate read failure.
|
|
5 | Cause the specified call to the write block
|
|
| routine to indicate write failure.
|
|
6 | After the next power cycle, indicate the
|
|
| mass storage device failed the power-on self-test, but
|
|
| completed the initialization sequence
|
|
| successfully. Only affects the
|
|
| printer state after the next power cycle.
|
|
7 | Cause the driver to behave, after the next power
|
|
| cycle, as if the mass storage device had the serial number
|
|
| 'SN00000000'. This is a one-shot effect and the
|
|
| driver reverts to normal behavior if the printer
|
|
| is power cycled a second time.
|
|
The second byte indicates on which call to the specified
|
|
block driver the failure will start to occur.
|
|
If the value of the first bytes is four or five, then the
|
|
value of the second byte in indicates which call to the
|
|
specified block driver routine will fail. A value of one
|
|
means the first call will fail. A value of two means the
|
|
second call will fail, and so on. If the value of the
|
|
first byte is one, two, three, six, or seven, then the
|
|
value of the second byte is ignored. Writing this object
|
|
causes any previous write to this object to be invalidated."
|
|
::= { settings-msbd2 1 }
|
|
|
|
mopy-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eStandard(4),
|
|
eEnhanced(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls or reports how mopies are generated. eOff
|
|
turns off the mopy feature. eAuto allows the device to
|
|
determine the best method for generating mopies based on
|
|
the device configuration. eStandard spools the I/O data
|
|
and replays the I/O data multiple times to generate the
|
|
mopies. eEnhanced spools the rasterized page images and
|
|
replays the rasterized data to generate the mopies.
|
|
Typically, the rasterized data will be larger and will
|
|
allow all but the first mopy to print at speed. If the
|
|
job being mopied is not extremely complex, then the
|
|
first mopy will print at speed also."
|
|
::= { settings-spooler 1 }
|
|
|
|
|
|
engine-media-modes-supported1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of engine media modes supported by the device.
|
|
The modes are each separated by a comma character. An
|
|
example string would be: 'Normal,Rough,Low,Vellum'."
|
|
::= { media-modes 1 }
|
|
|
|
|
|
hrmemorysize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of physical main memory contained by
|
|
the host.
|
|
Refer to RFC 1514, Host Resources MIB, for more details.
|
|
Additional information:
|
|
The unit of measure for this object is 1024 bytes.
|
|
The default value assumes the base printer with no
|
|
additional memory."
|
|
::= { hrStorage 2 }
|
|
|
|
|
|
prtconsolecolor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePunknown(2),
|
|
ePwhite(3),
|
|
ePred(4),
|
|
ePgreen(5),
|
|
ePblue(6),
|
|
ePcyan(7),
|
|
ePmagenta(8),
|
|
ePyellow(9),
|
|
ePorange(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The color of this light.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtConsoleLightEntry 4 }
|
|
|
|
|
|
phd1-model OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns product information identifying the PHD device.
|
|
Example: XXXX"
|
|
::= { phd1 1 }
|
|
|
|
|
|
phd1-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of this
|
|
particular PHD. May include serial number and firmware
|
|
revision."
|
|
::= { phd1 2 }
|
|
|
|
|
|
phd1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eInputPHD(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed as
|
|
PHD 1. See SIMM1-TYPE for an explanation of the
|
|
enumerations.
|
|
Additional information:
|
|
Returns an indication of whether or not the
|
|
envelope feeder is installed on the printer. A value of eEmpty means that
|
|
the envelope feeder is not installed."
|
|
::= { phd1 3 }
|
|
|
|
|
|
phd1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the installed
|
|
option. See SIMM1-CAPACITY for an explanation of the
|
|
meaning of the value of this object.
|
|
Additional information:
|
|
The LaserJet 4000 Series envelope feeder has a single tray."
|
|
::= { phd1 4 }
|
|
|
|
|
|
override-media-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eISOandJISA5(25),
|
|
eISOandJISA4(26),
|
|
eJISB5(45),
|
|
eMonarch(80),
|
|
eCommercial10(81),
|
|
eInternationalDL(90),
|
|
eInternationalC5(91),
|
|
eInternationalB5(100),
|
|
eCustom(101)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the media size that is to be used in place of the
|
|
currently requested media size.
|
|
Additional information:
|
|
When a request is received to print on a size and
|
|
type of media that is not currently available, this object contains the
|
|
desired size as set by the print job. This object should be set to a media
|
|
size that is currently available to the printer.
|
|
If a paper mount request is not pending, attempting to get or set this object
|
|
will cause <noSuchName> to be returned."
|
|
::= { settings-prt-eng 3 }
|
|
|
|
|
|
tray1-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eFoolscap(10),
|
|
eLedger(11),
|
|
eStatement(15),
|
|
eROC16K(17),
|
|
eISOandJISA6(24),
|
|
eISOandJISA5(25),
|
|
eISOandJISA4(26),
|
|
eISOandJISA3(27),
|
|
ePRC16K195X270(34),
|
|
eJISB6(44),
|
|
eJISB5(45),
|
|
eJISB4(46),
|
|
eJapanesePostcardSingle(71),
|
|
eJapanesePostcardDouble(72),
|
|
eIndexCard4x6(74),
|
|
eIndexCard5x8(75),
|
|
eIndexCard3x5(78),
|
|
eMonarch(80),
|
|
eCommercial10(81),
|
|
ePRC16K184X260(89),
|
|
eInternationalDL(90),
|
|
eInternationalC5(91),
|
|
eInternationalC6(92),
|
|
eInternationalB5(100),
|
|
eCustom(101),
|
|
eJapanseEnvLong3(110),
|
|
eJapanseEnvLong4(111),
|
|
ePhoto10x15(118),
|
|
ePhotoLSizeCard(121),
|
|
eIndexCard5x7(122),
|
|
eLegal216x340(127),
|
|
eJapaneseOufuku148x200(328),
|
|
eAnySize(32765)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the media size that is currently loaded in tray
|
|
#1. This object can be set to indicate the media size
|
|
currently loaded, if the printer supports input trays
|
|
that can not sense the media size. Complete list of
|
|
supported media sizes along with their dimensions are
|
|
listed in the ``Media Size Table'' near the end of this
|
|
document."
|
|
::= { intray1 1 }
|
|
|
|
|
|
tray1-media-available OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns a number that indicates how full the input tray
|
|
is. If the device can only detect empty / not empty the
|
|
device returns -1 for not empty and 0 for empty. If the
|
|
device can determine how full the tray is, the device
|
|
returns a percentage full from 0% to 100%
|
|
Additional information:
|
|
LaserJet 4V can only detect empty/not empty tray.
|
|
It returns -1 for not empty and 0 for empty."
|
|
::= { intray1 2 }
|
|
|
|
|
|
tray1-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the device specific name for tray 1."
|
|
::= { intray1 3 }
|
|
|
|
tray1-media-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a string identifying the media that is currently
|
|
loaded in tray #1. The media name string is the name associated
|
|
with the loaded media. The strings identifying different media
|
|
are user defined. Examples media name strings include 'HR
|
|
Company LetterHead', '1091 Invoice Form', 'White Bond',
|
|
'Canary', and 'White Recycled'."
|
|
::= { intray1 4 }
|
|
|
|
tray1-custom-media-width OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Width of media (in decipoints) loaded in tray 1."
|
|
::= { intray1 10 }
|
|
|
|
tray1-custom-media-length OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length of media (in decipoints) loaded in tray 1."
|
|
::= { intray1 11 }
|
|
|
|
tray1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTray(1),
|
|
eManualRoll(2),
|
|
eArss(3),
|
|
eManualSheet(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of input media support installed. eTray (1)
|
|
if the paper source is a tray eManualRoll (2) if the paper
|
|
source is a manually loaded roll eArss (3) if the paper source
|
|
is an anutomatically loaded roll (ARSS) eManualSheet (4) if the
|
|
paper source is only for a manually loaded single sheet"
|
|
::= { intray1 17 }
|
|
|
|
tray1-media-key OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the media key (index) in the database."
|
|
::= { intray1 20 }
|
|
tray2-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eLedger(11),
|
|
eStatement(15),
|
|
eROC16K(17),
|
|
eISOandJISA5(25),
|
|
eISOandJISA4(26),
|
|
eISOandJISA3(27),
|
|
ePRC16K195X270(34),
|
|
eJISB5(45),
|
|
eJISB4(46),
|
|
eCommercial10(81),
|
|
ePRC16K184X260(89),
|
|
eInternationalDL(90),
|
|
eInternationalC5(91),
|
|
eInternationalB5(100),
|
|
eJapanseEnvLong3(110),
|
|
eCustom(101),
|
|
eUnknownMediaSize(32767)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the media size that is currently configured in
|
|
tray #2. Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document.
|
|
Additional information:
|
|
If the tray drawer is open, a get on this object
|
|
will cause a status of
|
|
<genErr> to be
|
|
returned. If the tray is empty, the size that the
|
|
tray is configured for will be returned. If Tray 2
|
|
is a 500-sheet standard tray, eJISB5 and eUSExecutive
|
|
are not valid values."
|
|
::= { intray2 1 }
|
|
|
|
tray2-media-available OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns a number that indicates how full the input tray
|
|
is. If the device can only detect empty / not empty the
|
|
device returns -1 for not empty and 0 for empty. If the
|
|
device can determine how full the tray is, the device
|
|
returns a percentage full from 0% to 100%
|
|
Additional information:
|
|
LaserJet 4V can only detect empty/not empty tray.
|
|
It returns -1 for not empty and 0 for empty."
|
|
::= { intray2 2 }
|
|
|
|
|
|
tray2-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the device specific name for tray 2."
|
|
::= { intray2 3 }
|
|
|
|
tray2-media-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a string identifying the media that is currently
|
|
loaded in tray 2. See TRAY1-MEDIA-NAME for a complete
|
|
description."
|
|
::= { intray2 4 }
|
|
|
|
tray2-custom-media-width OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Width of media (in decipoints) loaded in tray 2."
|
|
::= { intray2 10 }
|
|
|
|
tray2-custom-media-length OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length of media (in decipoints) loaded in tray 2."
|
|
::= { intray2 11 }
|
|
|
|
tray2-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this input tray."
|
|
::= { intray2 12 }
|
|
|
|
tray2-fuser-temperature OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fuser temperature to be used when printing media
|
|
from Tray 2. The value zero is the default temperature.
|
|
Values less than zero are progressively lower and values
|
|
greater than zero are progressively higher. The range
|
|
of values supported is device specific.
|
|
Additional information:
|
|
See TRAY1-FUSER-TEMPERATURE."
|
|
::= { intray2 13 }
|
|
|
|
tray2-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTray(1),
|
|
eManualRoll(2),
|
|
eArss(3),
|
|
eManualSheet(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of input media support installed. eTray (1)
|
|
if the paper source is a tray eManualRoll (2) if the paper
|
|
source is a manually loaded roll eArss (3) if the paper source
|
|
is an anutomatically loaded roll (ARSS) eManualSheet (4) if the
|
|
paper source is only for a manually loaded single sheet"
|
|
::= { intray2 17 }
|
|
|
|
tray2-media-key OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the media key (index) in the database."
|
|
::= { intray2 20 }
|
|
|
|
tray3-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eFoolscap(10),
|
|
eLedger(11),
|
|
eStatement(15),
|
|
eROC16K(17),
|
|
eISOandJISA5(25),
|
|
eISOandJISA4(26),
|
|
eISOandJISA3(27),
|
|
ePRC16K195X270(34),
|
|
eJISB5(45),
|
|
eJISB4(46),
|
|
ePRC16K184X260(89),
|
|
eCustom(101),
|
|
eLegal216x340(127),
|
|
eUnknownMediaSize(32767)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the media size that is currently configured in
|
|
tray #3. Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document.
|
|
Additional information:
|
|
If the tray drawer is open, a get on this object
|
|
will cause a status of
|
|
<genErr> to be
|
|
returned. If the tray is empty, the size that the
|
|
tray is configured for will be returned."
|
|
::= { intray3 1 }
|
|
|
|
tray3-media-available OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns a number that indicates how full the input tray
|
|
is. If the device can only detect empty / not empty the
|
|
device returns -1 for not empty and 0 for empty. If the
|
|
device can determine how full the tray is, the device
|
|
returns a percentage full from 0% to 100%
|
|
Additional information:
|
|
LaserJet 4V can only detect empty/not empty tray.
|
|
It returns -1 for not empty and 0 for empty.
|
|
This object is only supported if a LC is installed.
|
|
Returns <noSuchName> status
|
|
if attempting to perform a Get on this OID with
|
|
no LC installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no LC installed."
|
|
::= { intray3 2 }
|
|
|
|
|
|
tray3-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the device specific name for tray 3.
|
|
Additional information:
|
|
This object is only supported if a LC is
|
|
installed.
|
|
Returns <noSuchName> status if
|
|
attempting to perform a Get on this OID with no LC
|
|
installed.
|
|
Returns <noSuchName>
|
|
status if attempting to perform a Set, EnableTrap, or
|
|
DisableTrap on this OID with no LC installed."
|
|
::= { intray3 3 }
|
|
|
|
tray3-media-name OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a string identifying the media that is currently
|
|
loaded in tray 3. See TRAY1-MEDIA-NAME for a complete
|
|
description."
|
|
::= { intray3 4 }
|
|
|
|
tray3-custom-media-width OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Width of media (in decipoints) loaded in tray 3."
|
|
::= { intray3 10 }
|
|
|
|
tray3-custom-media-length OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length of media (in decipoints) loaded in tray 3."
|
|
::= { intray3 11 }
|
|
|
|
tray3-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this input tray."
|
|
::= { intray3 12 }
|
|
|
|
tray3-fuser-temperature OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The fuser temperature to be used when printing media
|
|
from Tray 3. The value zero is the default temperature.
|
|
Values less than zero are progressively lower and values
|
|
greater than zero are progressively higher. The range
|
|
of values supported is device specific.
|
|
Additional information:
|
|
See TRAY1-FUSER-TEMPERATURE."
|
|
::= { intray3 13 }
|
|
|
|
tray3-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTray(1),
|
|
eManualRoll(2),
|
|
eArss(3),
|
|
eManualSheet(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of input media support installed. eTray (1)
|
|
if the paper source is a tray eManualRoll (2) if the paper
|
|
source is a manually loaded roll eArss (3) if the paper source
|
|
is an anutomatically loaded roll (ARSS) eManualSheet (4) if the
|
|
paper source is only for a manually loaded single sheet"
|
|
::= { intray3 17 }
|
|
|
|
tray3-media-key OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the media key (index) in the database."
|
|
::= { intray3 20 }
|
|
|
|
tray4-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eLedger(11),
|
|
eISOandJISA3(27),
|
|
eISOandJISA4(26),
|
|
eJISB4(46)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the media size that is currently configured in
|
|
tray #4. Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document.
|
|
Additional information:
|
|
The Media Size Table does not exist in this document.
|
|
Attempting to access this object when the tray is not installed
|
|
will result in an ErrorUnknownObjectIdentifier response from
|
|
the printer."
|
|
::= { intray4 1 }
|
|
|
|
tray4-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this input tray."
|
|
::= { intray4 12 }
|
|
|
|
|
|
tray5-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eFoolscap(10),
|
|
eStatement(15),
|
|
eROC16K(17),
|
|
eISOandJISA5(25),
|
|
eISOandJISA4(26),
|
|
ePRC16K195X270(34),
|
|
eJISB5(45),
|
|
ePRC16K184X260(89),
|
|
eCustom(101),
|
|
eLegal216x340(127),
|
|
eUnknownMediaSize(32767)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the media size that is currently configured in
|
|
tray #5. Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document.
|
|
Additional information:
|
|
If the tray drawer is open, a get on this object
|
|
will cause a status of
|
|
<genErr> to be
|
|
returned. If the tray is empty, the size that the
|
|
tray is configured for will be returned."
|
|
::= { intray5 1 }
|
|
|
|
tray5-media-name OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains a string identifying the media that is currently
|
|
loaded in tray 4. See TRAY1-MEDIA-NAME for a complete
|
|
description."
|
|
::= { intray5 4 }
|
|
|
|
tray5-custom-media-width OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Width of media (in decipoints) loaded in tray 4."
|
|
::= { intray5 10 }
|
|
|
|
tray5-custom-media-length OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Length of media (in decipoints) loaded in tray 4."
|
|
::= { intray5 11 }
|
|
|
|
tray5-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this input tray."
|
|
::= { intray5 12 }
|
|
|
|
tray5-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTray(1),
|
|
eManualRoll(2),
|
|
eArss(3),
|
|
eManualSheet(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of input media support installed. eTray (1)
|
|
if the paper source is a tray eManualRoll (2) if the paper
|
|
source is a manually loaded roll eArss (3) if the paper source
|
|
is an anutomatically loaded roll (ARSS) eManualSheet (4) if the
|
|
paper source is only for a manually loaded single sheet"
|
|
::= { intray5 17 }
|
|
|
|
tray5-media-key OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the media key (index) in the database."
|
|
::= { intray5 20 }
|
|
|
|
tray6-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eISOandJISA4(26),
|
|
eJISB4(46)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the media size that is currently configured in
|
|
tray #5. Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document.
|
|
Additional information:
|
|
If the tray drawer is open, a get on this object
|
|
will cause a status of
|
|
<genErr> to be
|
|
returned. If the tray is empty, the size that the
|
|
tray is configured for will be returned"
|
|
::= { intray6 1 }
|
|
|
|
|
|
tray6-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this input tray.
|
|
Additional information:
|
|
The internal trays belong to device 0 (base engine), the
|
|
envelope feeder is considered to be device 1
|
|
and the external input devices can number
|
|
between 2 and 6 depending on individual user
|
|
configurations."
|
|
::= { intray6 12 }
|
|
|
|
|
|
tray7-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eLedger(11),
|
|
eISOandJISA4(26),
|
|
eISOandJISA3(27),
|
|
eJISB4(46)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the media size that is currently configured in
|
|
tray #5. Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document.
|
|
Additional information:
|
|
If the tray drawer is open, a get on this object
|
|
will cause a status of
|
|
<genErr> to be
|
|
returned. If the tray is empty, the size that the
|
|
tray is configured for will be returned"
|
|
::= { intray7 1 }
|
|
|
|
|
|
tray7-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this input tray.
|
|
Additional information:
|
|
The internal trays belong to device 0 (base engine), the
|
|
envelope feeder is considered to be device 1
|
|
and the external input devices can number
|
|
between 2 and 6 depending on individual user
|
|
configurations.
|
|
NOTE: only TRAY6 and TRAY7 are listed here
|
|
because HP does not make a device with more than
|
|
two trays, but the Specification requires
|
|
support of up to 10 external trays. Therefore the
|
|
objects for TRAY8-PHD ... TRAY15-PHD will exist if
|
|
that many trays exist."
|
|
::= { intray7 12 }
|
|
|
|
|
|
|
|
outbin3-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
If cCancelJob is set, the current print job will
|
|
be cancelled regardless of other item settings.
|
|
This object describes the action that is performed
|
|
when the JOB-OUTPUT-AUTO-CONTINUE-TIMEOUT expires.
|
|
The action performed by the CONTINUE object being set
|
|
to eInitiateAction or the GO key being pressed on the
|
|
control panel may cause different actions. See the
|
|
CONTINUE object
|
|
description for information on the actions that
|
|
occur for those conditions.
|
|
NOTE: Because HP is marketing a device with a max of
|
|
16 bins the OUTBIN-OVERRIDE-MODE objects are 3-18 but
|
|
the external device specification requires support of
|
|
up to 315 output bins. Therefore if these bins exist
|
|
above 16, then the coresponding objects will also exist
|
|
OUTBIN19-OVERRIDE-MODE through OUTBIN317-OVERRIDE-MODE
|
|
The data for this object is stored in NVRAM."
|
|
::= { outbin3 9 }
|
|
|
|
|
|
outbin3-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
This is a read only object that returns the number of
|
|
20# pages that this bin can bind(i.e. staple). This
|
|
number is used by the host applications to prevent
|
|
jobs that exceed this amount from being sent to this
|
|
bin. If this bin does not have a finishing function
|
|
like stapling where this object is necessary the
|
|
object will return <badValue>.
|
|
NOTE: Because HP is marketing a device with a max of
|
|
16 bins the OUTBIN-MAXIMUM-BINDING objects are 3-18 but
|
|
the external device specification requires support of
|
|
up to 315 output bins. Therefore if these bins exist
|
|
above 16, then the coresponding objects will also exist
|
|
OUTBIN19-MAXIMUM-BINDING ... OUTBIN317-MAXIMUM-BINDING"
|
|
::= { outbin3 10 }
|
|
|
|
|
|
outbin3-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
This object will return the the device number that
|
|
contains this output bin. The envelope feed is
|
|
considered PHD1 thus this object will return
|
|
2-6 depending on where in the device chain the bin
|
|
exists.
|
|
NOTE: Because HP is marketing a device with a max of
|
|
16 bins the OUTBIN-OVERRIDE-MODE objects are 3-18 but
|
|
the external device specification requires support of
|
|
up to 315 output bins. Therefore if these bins exist
|
|
above 16, then the coresponding objects will also exist
|
|
OUTBIN19-PHD through OUTBIN317-PHD"
|
|
::= { outbin3 11 }
|
|
|
|
|
|
outbin3-error-info OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A device specific description of the last error
|
|
encountered for output bin 3. Each POS should document
|
|
the meaning of all supported error information.
|
|
Additional information:
|
|
This is a description of the current error state of a
|
|
finishing device. (ie stapler). If the bin does not
|
|
support any finishing capabilities then the object
|
|
will return <badValue>.
|
|
The possible return values are as follows:
|
|
Byte1, Byte2, and Byte3 should be 0x00. as they are
|
|
reserved for future use.
|
|
Byte4 is a bit field that can be interpreted as
|
|
follows:
|
|
bit 0 -- unused
|
|
bit 1 -- eBinderOut Out of staples
|
|
bit 2 -- eBinderLimit Too many pages to finish
|
|
bit 3 -- eBinderJam Staple jammed in stapler
|
|
bit 4 -- eBinderAlign Pages aren't aligned correctly
|
|
to finish.
|
|
bit 5 -- unused
|
|
bit 6 -- unused
|
|
bit 7 -- unused
|
|
|
|
NOTE: Because HP is marketing a device with a max of
|
|
16 bins the OUTBIN-MAXIMUM-BINDING objects are 3-18 but
|
|
the external device specification requires support of
|
|
up to 315 output bins. Therefore if these bins exist
|
|
above 16, then the coresponding objects will also exist
|
|
OUTBIN19-MAXIMUM-BINDING ... OUTBIN317-MAXIMUM-BINDING"
|
|
::= { outbin3 12 }
|
|
|
|
outbin4-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN3-OVERRIDE-MODE."
|
|
::= { outbin4 9 }
|
|
|
|
|
|
outbin4-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
See OUTBIN3-MAXIMUM-BINDING."
|
|
::= { outbin4 10 }
|
|
|
|
|
|
outbin4-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
See OUTBIN3-PHD."
|
|
::= { outbin4 11 }
|
|
|
|
outbin5-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN3-OVERRIDE-MODE."
|
|
::= { outbin5 9 }
|
|
|
|
|
|
outbin5-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
See OUTBIN3-MAXIMUM-BINDING."
|
|
::= { outbin5 10 }
|
|
|
|
|
|
outbin5-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
See OUTBIN3-PHD."
|
|
::= { outbin5 11 }
|
|
|
|
|
|
outbin6-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN3-OVERRIDE-MODE."
|
|
::= { outbin6 9 }
|
|
|
|
|
|
outbin6-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
See OUTBIN3-MAXIMUM-BINDING."
|
|
::= { outbin6 10 }
|
|
|
|
|
|
outbin6-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
See OUTBIN3-PHD."
|
|
::= { outbin6 11 }
|
|
|
|
|
|
outbin7-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN3-OVERRIDE-MODE."
|
|
::= { outbin7 9 }
|
|
|
|
|
|
outbin7-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
See OUTBIN3-MAXIMUM-BINDING."
|
|
::= { outbin7 10 }
|
|
|
|
|
|
outbin7-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
See OUTBIN3-PHD."
|
|
::= { outbin7 11 }
|
|
|
|
|
|
outbin8-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN3-OVERRIDE-MODE."
|
|
::= { outbin8 9 }
|
|
|
|
|
|
outbin8-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
See OUTBIN3-MAXIMUM-BINDING."
|
|
::= { outbin8 10 }
|
|
|
|
|
|
outbin8-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
See OUTBIN3-PHD."
|
|
::= { outbin8 11 }
|
|
|
|
|
|
outbin9-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN3-OVERRIDE-MODE."
|
|
::= { outbin9 9 }
|
|
|
|
|
|
outbin9-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
See OUTBIN3-MAXIMUM-BINDING."
|
|
::= { outbin9 10 }
|
|
|
|
|
|
outbin9-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
See OUTBIN3-PHD."
|
|
::= { outbin9 11 }
|
|
|
|
outbin9-error-info OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..65535))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A device specific description of the last error
|
|
encountered for output bin 9. Each POS should document
|
|
the meaning of all supported error information.
|
|
Additional information:
|
|
This is a description of the current error state of a
|
|
finishing device. (ie stapler). If the bin does not
|
|
support any finishing capabilities then the object
|
|
will return <badValue>.
|
|
The possible return values are as follows:
|
|
Byte1, Byte2, and Byte3 should be 0x00. as they are
|
|
reserved for future use.
|
|
Byte4 is a bit field that can be interpreted as
|
|
follows:
|
|
bit 0 -- unused
|
|
bit 1 -- eBinderOut Out of staples
|
|
bit 2 -- eBinderLimit Too many pages to finish
|
|
bit 3 -- eBinderJam Staple jammed in stapler
|
|
bit 4 -- eBinderAlign Pages aren't aligned correctly
|
|
to finish.
|
|
bit 5 -- unused
|
|
bit 6 -- unused
|
|
bit 7 -- unused
|
|
|
|
OUTBIN3 is the topmost bin on the output device. This bin
|
|
replaces the left output bin on the base printer. OUTBIN4
|
|
through OUTBIN8 are the additional 5 regular bins supplied
|
|
by the MBM5S device. OUTBIN9 is the stapler unit and is
|
|
the lowest bin in the device.
|
|
NOTE: Because HP is marketing a device with a max of
|
|
7 bins (MBM5S) the OUTBINn-ERROR-INFO objects are
|
|
3-9 but the external device specification requires
|
|
support of up to 315 output bins. Therefore if these
|
|
bins exist above 7, then the coresponding objects will
|
|
also exist OUTBIN10-ERROR-INFO through OUTBIN317-ERROR-INFO."
|
|
::= { outbin9 12 }
|
|
|
|
outbin10-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN3-OVERRIDE-MODE."
|
|
::= { outbin10 9 }
|
|
|
|
|
|
outbin10-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
See OUTBIN3-MAXIMUM-BINDING."
|
|
::= { outbin10 10 }
|
|
|
|
|
|
outbin10-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
See OUTBIN3-PHD."
|
|
::= { outbin10 11 }
|
|
|
|
|
|
outbin11-override-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the device behavior when this output bin
|
|
condition causes printing to stop.
|
|
cCancelJob - The device cancels the job.
|
|
cOutbinFullOverride - The device sends subsequent
|
|
media to the overflow bin.
|
|
cOutbinAttentionOverride - The device ignores the
|
|
attention condition and continues printing.
|
|
cBinderAttentionOverride - The device ignores the
|
|
binder attention condition and continues printing.
|
|
Additional information:
|
|
See OUTBIN3-OVERRIDE-MODE."
|
|
::= { outbin11 9 }
|
|
|
|
|
|
outbin11-maximum-binding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of sheets of 20 pound paper that can
|
|
be bound by the binding device that serves this output
|
|
bin. If a job exceeds this number and the job has
|
|
requested binding, cBindingError will be set in NOT-
|
|
READY-DESTINATION-PRINT-ENGINE.
|
|
Additional information:
|
|
See OUTBIN3-MAXIMUM-BINDING."
|
|
::= { outbin11 10 }
|
|
|
|
|
|
outbin11-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this output bin.
|
|
Additional information:
|
|
See OUTBIN3-PHD."
|
|
::= { outbin11 11 }
|
|
|
|
|
|
media-names-available OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object controls which of the MEDIAx-
|
|
NAME objects are supported. If a bit is set to zero,
|
|
then attempting to get or set the corresponding MEDIAx-
|
|
NAME objects will return
|
|
<noSuchName>.
|
|
Additional information:
|
|
Setting a bit to one will cause the corresponding
|
|
MEDIAn- objects to be available (attempting to access
|
|
an unavailable object will return <noSuchName>).
|
|
MEDIA1- objects are always present in LaserJet 4000 Series, as this is the default
|
|
media. If this object is set to a value that does not include
|
|
cMediaName1Available, that bit will be set and a status of
|
|
<noError> will be returned.
|
|
cMediaName12Available cannot be changed on LaserJet 4000 Series, as MediaName12
|
|
is not a supported Media Name for that product. Attempts to set
|
|
cMediaName12Available will cause <badValue>
|
|
to be returned."
|
|
::= { settings-print-media 1 }
|
|
|
|
|
|
media4-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media4 4 }
|
|
|
|
|
|
media6-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media6 4 }
|
|
|
|
|
|
media10-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media10 4 }
|
|
|
|
|
|
media11-engine-media-mode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The engine processing characteristics that are to be
|
|
applied to this media. The processing characteristics
|
|
are device specific.
|
|
Additional information:
|
|
See the description for MEDIA1-ENGINE-MEDIA-MODE."
|
|
::= { media11 4 }
|
|
|
|
engine-media-mode1-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of sheets printed using this media mode. The
|
|
device POS should state whether this value is lost
|
|
across a power cycle or is kept in permanent storage.
|
|
Additional information:
|
|
The value of this object is persistent across a power cycle.
|
|
Engine media mode 1 is normal fusing.
|
|
Engine media mode 2 is transparency fusing.
|
|
Engine media mode 3 is glossy fusing.
|
|
Enigne media mode 4 is heavy media fusing.
|
|
Engine media mode 5 is envelope fusing."
|
|
::= { media-mode1 2 }
|
|
|
|
|
|
engine-media-mode2-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of sheets printed using this media mode. The
|
|
device POS should state whether this value is lost
|
|
across a power cycle or is kept in permanent storage.
|
|
Additional information:
|
|
The value of this object is persistent across a power cycle.
|
|
Engine media mode 1 is normal fusing.
|
|
Engine media mode 2 is transparency fusing.
|
|
Engine media mode 3 is glossy fusing.
|
|
Enigne media mode 4 is heavy media fusing.
|
|
Engine media mode 5 is envelope fusing."
|
|
::= { media-mode2 2 }
|
|
|
|
|
|
engine-media-mode3-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of sheets printed using this media mode. The
|
|
device POS should state whether this value is lost
|
|
across a power cycle or is kept in permanent storage.
|
|
Additional information:
|
|
The value of this object is persistent across a power cycle.
|
|
Engine media mode 1 is normal fusing.
|
|
Engine media mode 2 is transparency fusing.
|
|
Engine media mode 3 is glossy fusing.
|
|
Enigne media mode 4 is heavy media fusing.
|
|
Engine media mode 5 is envelope fusing."
|
|
::= { media-mode3 2 }
|
|
|
|
|
|
engine-media-mode4-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of sheets printed using this media mode. The
|
|
device POS should state whether this value is lost
|
|
across a power cycle or is kept in permanent storage.
|
|
Additional information:
|
|
The value of this object is persistent across a power cycle.
|
|
Engine media mode 1 is normal fusing.
|
|
Engine media mode 2 is transparency fusing.
|
|
Engine media mode 3 is glossy fusing.
|
|
Enigne media mode 4 is heavy media fusing.
|
|
Engine media mode 5 is envelope fusing."
|
|
::= { media-mode4 2 }
|
|
|
|
|
|
engine-media-mode5-page-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of sheets printed using this media mode. The
|
|
device POS should state whether this value is lost
|
|
across a power cycle or is kept in permanent storage.
|
|
Additional information:
|
|
The value of this object is persistent across a power cycle.
|
|
Engine media mode 1 is normal fusing.
|
|
Engine media mode 2 is transparency fusing.
|
|
Engine media mode 3 is glossy fusing.
|
|
Enigne media mode 4 is heavy media fusing.
|
|
Engine media mode 5 is envelope fusing."
|
|
::= { media-mode5 2 }
|
|
|
|
media-size-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of impressions printed on sheets of this
|
|
media size. The device POS should state whether this
|
|
value is lost across a power cycle or is kept in
|
|
permanent storage.
|
|
Additional information:
|
|
The value of this object is persistent across a power cycle.
|
|
|
|
The index for these objects, the last number of the OID, uniquely identifies the paper size. This value
|
|
corresponds to the page sizes listed below. These values are also documented in the PCL Implementor's Guide
|
|
and the PML Master MIB.
|
|
|
|
1 US-Executive
|
|
2 US-Letter
|
|
3 US-Legal
|
|
25 ISO and JIS A5
|
|
26 ISO and JIS A4
|
|
45 JIS B5
|
|
80 LaserJet 4500
|
|
81 Commercal-10
|
|
90 International DL
|
|
91 International C5
|
|
100 International B5
|
|
101 Custom"
|
|
::= { media-size 1 }
|
|
|
|
media-size-west-edge-first-side-offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the number of 300 dpi dots by which the
|
|
image is shifted relative to the west edge of the medium
|
|
(see NORTH-EDGE-OFFSET). The adjustment is for the
|
|
first printed side of the medium only. A positive value
|
|
moves the image away from the west edge of the medium.
|
|
A negative value moves the image closer to the west edge
|
|
of the medium. The value 0 will return the image to its
|
|
factory default position.
|
|
Additional information:
|
|
Returns or sets the number of 300 dpi dots by which the
|
|
image is shifted relative to the west edge of the medium
|
|
(see NORTH-EDGE-OFFSET). The adjustment is for the
|
|
first printed side of the medium only. A positive value
|
|
moves the image away from the west edge of the medium.
|
|
A negative value moves the image closer to the west edge
|
|
of the medium. The value 0 will return the image to its
|
|
factory default position. The values in the sub array index
|
|
are from the media size table in the hpmib.
|
|
The data for this object is stored in NVRAM."
|
|
::= { media-size 2 }
|
|
|
|
|
|
media-size-west-edge-second-side-offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns or sets the number of 300 dpi dots by which the
|
|
image is shifted relative to the west edge of the medium
|
|
(see NORTH-EDGE-OFFSET). The adjustment is for the
|
|
second printed side of the medium only. A positive
|
|
value moves the image away from the west edge of the
|
|
medium. A negative value moves the image closer to the
|
|
west edge of the medium. The value 0 will return the
|
|
image to its factory default position.
|
|
Additional information:
|
|
Returns or sets the number of 300 dpi dots by which the
|
|
image is shifted relative to the west edge of the medium
|
|
(see NORTH-EDGE-OFFSET). The adjustment is for the
|
|
second printed side of the medium only. A positive value
|
|
moves the image away from the west edge of the medium.
|
|
A negative value moves the image closer to the west edge
|
|
of the medium. The value 0 will return the image to its
|
|
factory default position. The values in the sub array index
|
|
are from the media size table in the hpmib.
|
|
The data for this object is stored in NVRAM."
|
|
::= { media-size 3 }
|
|
|
|
|
|
prtoutputdefaultindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtOutputIndex corresponding to the default
|
|
output sub-unit; that is, this object selects the default
|
|
output destination.
|
|
This value shall be -1 if there is no default output subunit specified
|
|
for the printer as a whole. In this case, the actual default
|
|
output subunit may be specified by means outside the scope of this
|
|
MIB, such as by each interpreter in a printer with multiple
|
|
interpreters.
|
|
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4050 Series (LaserJet 4050) has two output bins in the
|
|
base product: a face-up bin on the back of the engine and a
|
|
face-down bin on the top of the engine. These bins are not
|
|
firmware-selectable; instead, paper is diverted to the face-down
|
|
bin only if the face-up bin is physically closed. Therefore,
|
|
these bins are considered together as the 'standard' bin. However,
|
|
if an HCO is attached to the engine, users will be able to select
|
|
between an HCO bin and the 'standard' bin, which may be either the
|
|
face-up or face-down bin, depending upon whether the face-up bin
|
|
is open. With external output bins attached, the value of this
|
|
object will be settable from the control panel and by the PJL
|
|
OUTBIN variable."
|
|
::= { prtGeneralEntry 7 }
|
|
|
|
|
|
prtinputtype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePunknown(2),
|
|
ePsheetFeedAutoRemovableTray(3),
|
|
ePsheetFeedAutoNonRemovableTray(4),
|
|
ePsheetFeedManual(5),
|
|
ePcontinuousRoll(6),
|
|
ePcontinuousFanFold(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of technology (discriminated primarily according to
|
|
feeder mechanism type) employed by the input sub-unit. Note,
|
|
the Optional Input Class provides for a descriptor field to
|
|
further qualify the other choice.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Tray 1 is the multi-purpose tray and is always present.
|
|
It supports both sheets and envelopes. Its type is
|
|
ePsheetFeedAutoNonRemovableTray.
|
|
Tray 2 is a removable tray that comes standard
|
|
with the printer, although it is usually not removed
|
|
from the printer. It is of type
|
|
ePsheetFeedAutoRemovableTray.
|
|
Tray 3 is either a 250-sheet standard tray in the
|
|
2x250 base engine configuration or a 500-sheet optional tray
|
|
in the 1x500 base engine configuration. (The optional
|
|
tray is only recognized if it's installed before the
|
|
printer is powered on.) It is of type
|
|
ePsheetFeedAutoRemovableTray.
|
|
The 4th tray in this array is the envelope feeder. It
|
|
can be detected even when it is installed while the
|
|
printer is powered on.
|
|
Tray 5 is a 500-sheet optional tray that cannot be
|
|
installed while the printer is powered on. It is of type
|
|
ePsheetFeedAutoRemovableTray."
|
|
::= { prtInputEntry 2 }
|
|
|
|
|
|
prtinputdimunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit of measurement for use calculating and relaying
|
|
dimensional values for this input sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Following is a table of paper sizes and dimensions
|
|
for each paper size supported by LaserJet 4000 Series:
|
|
|
|
Size Inches (ten-thousandths) Millimeters
|
|
--------------- ------------------------ -----------
|
|
eUSExecutive 72500 x 105000 184150 x 266700
|
|
eUSLetter 85000 x 110000 215900 x 279400
|
|
eUSLegal 85000 x 140000 215900 x 355600
|
|
eISOandJISA5 58286 x 82677 148000 x 210000
|
|
eISOandJISA4 82677 x 116929 210000 x 297000
|
|
eJISB5 71654 x 101181 182000 x 257000
|
|
eMonarch 38750 x 75000 98425 x 190500
|
|
eCommercial10 41250 x 95000 104775 x 241300
|
|
eInternationalDL 43307 x 86614 110000 x 220000
|
|
eInternationalC5 63780 x 90157 162000 x 229000
|
|
eInternationalB5 69291 x 98425 176000 x 250000
|
|
eCustom 85000 x 140000 (max) 215900 x 355600 (max) "
|
|
::= { prtInputEntry 3 }
|
|
|
|
|
|
prtinputmediadimfeeddirdeclared OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides the value of the declared dimension, in
|
|
the feed direction, of the media that is (or, if empty, was or
|
|
will be) in this input sub-unit. The feed direction is the
|
|
direction in which the media is fed on this sub-unit. This
|
|
dimension is measured in input sub-unit dimensional units
|
|
(prtInputDimUnit). If this input sub-unit can reliably sense
|
|
this value, the value is sensed by the printer and may not be
|
|
changed by management requests. Otherwise, the value may be
|
|
changed. The value (-1) means other and specifically means
|
|
that this sub-unit places no restriction on this parameter.
|
|
The value (-2) indicates unknown.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
For trays 2, 3, and 5 (which can reliably sense this
|
|
value) these objects behave exactly the same as prtInputMediaDimFeedDirChosen.
|
|
Attempting to set the objects for tray 2, 3, or 5 will cause
|
|
<noSuchName> to be returned.
|
|
The default values assume the trays are configured for letter size paper (or COM10,
|
|
in the case of the envelope feeder). For tray 1, the value is the dimension for
|
|
the media size currently declared. For the envelope feeder (tray 4), the value is
|
|
the dimension for the media size currently declared.
|
|
Valid values are 0 to 268435455. If a value within 0.2 inches of a standard
|
|
size (e.g. 85001) is chosen when setting these objects, the standard size will
|
|
be set for the specified tray if the value of prtInputMediaDimXFeedDirDeclared
|
|
is also set to within 0.2 inches of the same standard size. If the value is not
|
|
within 0.2 inches, Custom will be chosen as the size if it is supported by the
|
|
specified tray, otherwise the first available standard size for the tray will
|
|
be selected."
|
|
::= { prtInputEntry 4 }
|
|
|
|
|
|
prtinputmediadimxfeeddirdeclared OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides the value of the declared dimension, in
|
|
the cross feed direction, of the media that is (or, if empty,
|
|
was or will be) in this input sub-unit. The cross feed
|
|
direction is ninety degrees relative to the feed direction
|
|
associated with this sub-unit. This dimension is measured in
|
|
input sub-unit dimensional units (prtInputDimUnit). If this
|
|
input sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed by management
|
|
requests. Otherwise, the value may be changed. The value (-1)
|
|
means other and specifically means that this sub-unit places
|
|
no restriction on this parameter. The value (-2) indicates
|
|
unknown.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
For trays 2, 3, and 5 (which can reliably sense this
|
|
value) these objects behave exactly the same as prtInputMediaDimXFeedDirChosen.
|
|
Attempting to set these objects for tray 2, 3, and 5 will cause
|
|
<noSuchName> to be returned.
|
|
The default values assume the trays are configured for letter size paper (or COM10,
|
|
in the case of the envelope feeder). For tray 1 the value is the dimension for the
|
|
media size currently declared.
|
|
Valid values are 0 to 268435455. If a value within 0.2 inches of a standard
|
|
size (e.g. 85001) is chosen when setting these objects, the standard size will
|
|
be set for the specified tray if the value of prtInputMediaDimFeedDirDeclared
|
|
is also set to within 0.2 inches of the same standard size. If the value is not
|
|
within 0.2 inches, Custom will be chosen as the size if it is supported by the
|
|
specified tray, otherwise the first available standard size for the tray will
|
|
be selected."
|
|
::= { prtInputEntry 5 }
|
|
|
|
|
|
prtinputmediadimfeeddirchosen OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The printer will act as if media of the chosen dimension (in
|
|
the feed direction) is present in this input source. Note
|
|
that this value will be used even if the input tray is empty.
|
|
Feed dimension measurements are taken relative to the feed
|
|
direction associated with that sub-unit and are in input sub-unit
|
|
dimensional units (MediaUnit). If the printer supports the
|
|
declared dimension, the granted dimension is the same as
|
|
the declared dimension. If not, the granted dimension is
|
|
set to the closest dimension that the printer supports
|
|
when the declared dimension is set. The value (-1) means
|
|
other and specifically indicates that this sub-unit
|
|
places no restriction on this parameter. The value (-2)
|
|
indicates unknown.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The objects for trays 2, 3, and 5 reflect the
|
|
configuration of the corresponding trays. When the tray is removed, a value
|
|
of -2 is returned. The default values assume the trays are configured for
|
|
letter size paper (or COM10, in the case of the envelope feeder). For tray 1
|
|
and the envelope feeder, the object returns the value of the media size for
|
|
which the tray is currently configured because those trays cannot sense what
|
|
size media they contain."
|
|
::= { prtInputEntry 6 }
|
|
|
|
|
|
prtinputmediadimxfeeddirchosen OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The printer will act as if media of the chosen dimension (in
|
|
the cross feed direction) is present in this input source.
|
|
Note that this value will be used even if the input tray is
|
|
empty. The cross feed direction is ninety degrees relative
|
|
to the feed direction associated with this sub-unit. This
|
|
dimension is measured in input sub-unit dimensional units
|
|
(MediaUnit). If the printer supports the declared
|
|
dimension, the granted dimension is the same as the
|
|
declared dimension. If not, the granted dimension is set
|
|
to the closest dimension that the printer supports when
|
|
the declared dimension is set. The value (-1) means other
|
|
and specifically indicates that this sub-unit places no
|
|
restriction on this parameter. The value (-2) indicates
|
|
unknown.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The objects for trays 2, 3, and 5 reflect the
|
|
configuration of the corresponding trays. When the tray is removed, a value
|
|
of -2 is returned. The default values assume the trays are configured for
|
|
letter size paper (or COM10, in the case of the envelope feeder). The objects
|
|
for tray 1 and the envelope feeder return the value of the media size for which
|
|
the tray is currently configured because those trays cannot sense what size media
|
|
they contain."
|
|
::= { prtInputEntry 7 }
|
|
|
|
|
|
prtinputcapacityunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4),
|
|
ePsheets(8),
|
|
ePfeet(16),
|
|
ePmeters(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit of measurement for use in calculating and relaying
|
|
capacity values for this input sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
A sheet is a single piece of 20 pound paper. For tray
|
|
4, the envelope feeder, a sheet is one envelope"
|
|
::= { prtInputEntry 8 }
|
|
|
|
|
|
prtinputmaxcapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum capacity of the input sub-unit in input
|
|
sub-unit capacity units (PrtCapacityUnitTC). There is no
|
|
convention associated with the media itself so this value
|
|
reflects claimed capacity. If this input sub-unit can
|
|
reliably sense this value, the value is sensed by the
|
|
printer and may not be changed by management requests;
|
|
otherwise, the value may be written (by a Remote
|
|
Control Panel or a Management Application).
|
|
The value (-1) means other and specifically
|
|
indicates that the sub-unit places no restrictions
|
|
on this parameter. The value (-2) means unknown.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML TRAYn-MAXIMUM-CAPACITY. This is
|
|
specified assuming 20 pound paper for the paper trays."
|
|
::= { prtInputEntry 9 }
|
|
|
|
|
|
prtinputcurrentlevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current capacity of the input sub-unit in input
|
|
sub-unit capacity units (PrtCapacityUnitTC). If this input
|
|
sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed by
|
|
management requests; otherwise, the value may
|
|
be written (by a Remote Contol Panel or a
|
|
Management Application). The value (-1) means other and
|
|
specifically indicates that the sub-unit places no
|
|
restrictions on this parameter. The value (-2) means unknown.
|
|
The value (-3) means that the printer knows that at least one
|
|
unit remains.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series can only detect empty/not empty for its
|
|
trays. It returns -3 for not empty and 0 for empty.
|
|
If a tray is removed, a value of -2 (unknown) will
|
|
be returned."
|
|
::= { prtInputEntry 10 }
|
|
|
|
|
|
prtinputstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of this input sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML STATUS-TRAY-MISSING and
|
|
STATUS-TRAY-EMPTY.
|
|
Values returned by the firmware are detailed in the
|
|
following table. 'Value Or'd Due To Condition' indicates
|
|
that the specified value will be logically or'd into the
|
|
value for this object when the specified Condition occurs.
|
|
Condition Value Or'd Due To Condition
|
|
----------------------- ------------------------
|
|
Tray Lifter Error 3
|
|
Tray not installed or
|
|
not inserted or not
|
|
occupied 1
|
|
Tray is current source tray
|
|
and paper is moving 6
|
|
Tray involved in paper mount 16 + 32
|
|
Value 3 or 1 is Or'd in 8
|
|
Tray is lifting 64 "
|
|
::= { prtInputEntry 11 }
|
|
|
|
|
|
prtinputmedianame OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of the media contained in this input sub-unit;
|
|
This description is intended for display to a human operator.
|
|
This description is not processed by the printer. It is used
|
|
to provide information not expressible in terms of the other
|
|
media attributes (e.g. prtInputMediaDimFeedDirChosen,
|
|
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
|
|
prtInputMediaType). An example would be `legal tender bond
|
|
paper'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML TRAYn-MEDIA-NAME.
|
|
If set to a string other than one contained by a MEDIAn-NAME
|
|
object, a status of <badValue> is returned.
|
|
If set to a string that is unsupported for the specified tray
|
|
object, a status of <badValue> is returned.
|
|
After Build5.0 (LaserJet 8100 Series) Cassette trays will not support
|
|
Transparency nor Label media types.
|
|
The value of this object is saved across a power cycle."
|
|
::= { prtInputEntry 12 }
|
|
|
|
|
|
prtinputname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name assigned to this input sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML TRAYn-NAME."
|
|
::= { prtInputEntry 13 }
|
|
|
|
|
|
prtinputvendorname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vendor name of this input sub-unit.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtInputEntry 14 }
|
|
|
|
|
|
prtinputmodel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The model name of this input sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series does not specify a model name for Tray1 or Tray2,
|
|
nor for Tray 3 in the 2x250 tray configuration. However, if Tray 3
|
|
is installed in the 1x500 configuration, 'Optional Cassette C4124A' will
|
|
be returned. Tray 3, 4, and 5 objects do not exist unless those trays
|
|
are installed."
|
|
::= { prtInputEntry 15 }
|
|
|
|
|
|
prtinputversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of this input sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series does not specify a version number
|
|
for the input trays."
|
|
::= { prtInputEntry 16 }
|
|
|
|
|
|
prtinputserialnumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number assigned to this input sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series does not specify a serial number for the
|
|
input trays."
|
|
::= { prtInputEntry 17 }
|
|
|
|
|
|
prtinputdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A free-form text description of this input
|
|
sub-unit in the localization specified by
|
|
prtGeneralCurrentLocalization.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtInputEntry 18 }
|
|
|
|
|
|
prtinputsecurity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePon(3),
|
|
ePoff(4),
|
|
ePnotPresent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if this input sub-unit has some security
|
|
associated with it.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
No security mechanism provided."
|
|
::= { prtInputEntry 19 }
|
|
|
|
|
|
prtinputmedialoadtimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the printer is not able to print due to a subunit
|
|
being empty or the requested media must be manually loaded, the
|
|
printer will wait for the duration (in seconds) specified by this
|
|
object. Upon expiration of the timeout, the printer will take the
|
|
action specified by prtInputNextIndex.
|
|
The event which causes the printer to enter the waiting state is
|
|
product specific. If the printer is not waiting for manually fed
|
|
media, it may switch from an empty subunit to a different subunit
|
|
without waiting for the timeout to expire.
|
|
A value of (-1) implies 'other' or 'infinite' which translates to
|
|
'wait forever'. The action which causes printing to continue is
|
|
product specific. A value of (-2) implies 'unknown'.
|
|
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object simply reflects the value of the
|
|
JOB-INPUT-AUTO-CONTINUE-TIMEOUT object. See the description of that object
|
|
for additional information."
|
|
::= { prtInputEntry 24 }
|
|
|
|
|
|
prtinputnextindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtInputIndex corresponding to the input
|
|
subunit which will be used when this input subunit is emptied and
|
|
the timeout specified by prtInputMediaLoadTimeout expires. A
|
|
value of zero(0) indicates that auto input switching will not
|
|
occur when this input subunit is emptied. If the timeout
|
|
specified by prtInputLoadMediaTimeout expires and this value is
|
|
zero(0), the job will be aborted. A value of (-1) means other.
|
|
The value (-2) means 'unknown' and specifically indicates that an
|
|
implementation specific method will determine the next input
|
|
subunit to use at the time this subunit is emptied and the
|
|
timeout expires. The value(-3) means input switching is not
|
|
supported for this subunit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object reflects the state of JOB-INPUT-AUTO-CONTINUE-MODE
|
|
and JOB-INPUT-AUTO-CONTINUE-TIMEOUT. If
|
|
JOB-INPUT-AUTO-CONTINUE-TIMEOUT is set to -1 or
|
|
JOB-INPUT-AUTO-CONTINUE-MODE is set up to cancel the job,
|
|
this object will return 0. If JOB-INPUT-AUTO-CONTINUE-TIMEOUT
|
|
is >= 0 and JOB-INPUT-AUTO-CONTINUE-MODE is not set up to
|
|
cancel the job, this object will return -2, meaning that
|
|
a product-specific tray switching action will occur."
|
|
::= { prtInputEntry 26 }
|
|
|
|
|
|
prtoutputtype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePunknown(2),
|
|
ePremovableBin(3),
|
|
ePunRemovableBin(4),
|
|
ePcontinuousRollDevice(5),
|
|
ePmailBox(6),
|
|
ePcontinousFanFold(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of technology supported by this output sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series has two built-in output bins: a face-down
|
|
bin located at the top of the printer and a face-up bin located
|
|
at the rear of the printer. However, neither of these bins is
|
|
firmware-selectable, so both bins are considered together as the
|
|
'standard' bin. LaserJet 4000 Series supports HCO devices as well as a
|
|
stacker/stapler, but these devices are currently T.B.D."
|
|
::= { prtOutputEntry 2 }
|
|
|
|
|
|
prtoutputcapacityunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4),
|
|
ePsheets(8),
|
|
ePfeet(16),
|
|
ePmeters(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit of measurement for use in calculating and relaying
|
|
capacity values for this output sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
A sheet is a single piece of 20 pound paper."
|
|
::= { prtOutputEntry 3 }
|
|
|
|
|
|
prtoutputmaxcapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum capacity of this output sub-unit in output
|
|
sub-unit capacity units (PrtCapacityUnitTC). There is no
|
|
convention associated with the media itself so this value
|
|
essentially reflects claimed capacity. If this output
|
|
sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed by management
|
|
requests; otherwise, the value may be written
|
|
(by a Remote Control Panel or a Management Application).
|
|
The value (-1) means other and specifically indicates
|
|
that the sub-unit places no restrictions on this parameter.
|
|
The value (-2) means unknown.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML OUTBINn-MAXIMUM-CAPACITY.
|
|
LaserJet 4000 Series cannot sense the amount of paper in its standard output
|
|
bin; however, the face-up bin can hold 50 sheets of 20lb. paper,
|
|
and the face-down bin can hold 250 sheets. External output devices
|
|
are currently T.B.D."
|
|
::= { prtOutputEntry 4 }
|
|
|
|
|
|
prtoutputremainingcapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining capacity of the possible output sub-unit
|
|
capacity in output sub-unit capacity units (PrtCapacityUnitTC)
|
|
of this output sub-unit. If this output sub-unit can
|
|
reliably sense this value, the value is sensed by the
|
|
printer and may not be modified by management requests;
|
|
otherwise, the value may be written (by
|
|
a Remote Control Panel or a Management
|
|
Application). The value (-1) means other and
|
|
specifically indicates that the sub-unit places no
|
|
restrictions on this parameter. The value (-2) means
|
|
unknown. The value (-3) means that the printer knows that
|
|
there remains capacity for at least one unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML NOT-READY-OUTBIN-FULL and
|
|
STATUS-OUTBIN-FULL.
|
|
LaserJet 4000 Series is capable of determining when the face-down
|
|
bin goes full, but not the level of that bin. LaserJet 4000 Series
|
|
is not capable of determining whether the face-up bin
|
|
is full. RemainingCapacity capabilities of the
|
|
stapler/stacker, as well as unplanned HCO devices,
|
|
are currently T.B.D.
|
|
LaserJet 4000 Series will report a value of 0 when the face-down
|
|
bin is full and -3 when the face down bin is not full."
|
|
::= { prtOutputEntry 5 }
|
|
|
|
|
|
prtoutputstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of this output sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML NOT-READY-OUTBIN-MISSING and
|
|
STATUS-OUTBIN-MISING.
|
|
The default values assume all bins are empty.
|
|
See SubUnitStatus in RFC1759 Printer MIB for details on values reported by
|
|
this object. LaserJet 4000 Series will not include values Available and Standby (2),
|
|
Available and Active (4), Unknown (5) or Transitioning to Intended State
|
|
(64).
|
|
Values returned by the firmware are detailed in the
|
|
following table. 'Value Or'd Due To Condition' indicates
|
|
that the specified value will be logically or'd into the
|
|
value for this object when the specified Condition occurs.
|
|
Condition Value Or'd Due To Condition
|
|
----------------------- ------------------------
|
|
Binder Error 3
|
|
Bin full, binder empty,
|
|
bind limit reached, binder
|
|
align error, bin attention
|
|
error, or bin attention
|
|
warning 1
|
|
Bin is current bin and
|
|
paper is moving 6
|
|
Bin is the bin responsible
|
|
for Bin Full error message
|
|
being displayed 16 + 32
|
|
Value 1 or 3 is Or'd in 8 "
|
|
::= { prtOutputEntry 6 }
|
|
|
|
|
|
prtoutputname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..15))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name assigned to this output sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML OUTBINn-NAME.
|
|
The characters must be in the range 20H to 7FH except
|
|
5C cannot be used. When this string is displayed on
|
|
the control panel the Roman-8 symbol set is used."
|
|
::= { prtOutputEntry 7 }
|
|
|
|
|
|
prtoutputvendorname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vendor name of this output sub-unit.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtOutputEntry 8 }
|
|
|
|
|
|
prtoutputmodel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name assigned to this output sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series does not support a model number for its
|
|
built-in output bins. This object may change in the
|
|
future when external output devices are added."
|
|
::= { prtOutputEntry 9 }
|
|
|
|
|
|
prtoutputversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of this output sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Returns device-specific information about the configuration
|
|
of the output bin. May include information about the type of
|
|
processing that can be done to media sent to this bin;
|
|
processing includes but is not limited to binding, punching,
|
|
folding and sealing. Format of this object is specified by
|
|
the output device documentation."
|
|
::= { prtOutputEntry 10 }
|
|
|
|
|
|
prtoutputserialnumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number assigned to this output sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series does not support a serial number for output
|
|
devices."
|
|
::= { prtOutputEntry 11 }
|
|
|
|
|
|
prtoutputdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A free-form text description of this output sub-unit in the
|
|
localization specified by prtGeneralCurrentLocalization.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtOutputEntry 12 }
|
|
|
|
|
|
prtoutputsecurity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePon(3),
|
|
ePoff(4),
|
|
ePnotPresent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if this output sub-unit has some security associated
|
|
with it and if that security is enabled or not.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
No security mechanism provided."
|
|
::= { prtOutputEntry 13 }
|
|
|
|
|
|
prtoutputdimunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit of measurement for use in calculating and relaying
|
|
dimensional values for this output sub-unit.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
See the description for prtInputDimUnit for a table
|
|
of supported paper sizes and their dimensions for LaserJet 4000 Series."
|
|
::= { prtOutputEntry 14 }
|
|
|
|
|
|
prtoutputmaxdimfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum dimensions supported by this output sub-unit
|
|
for measurements taken parallel relative to the feed
|
|
direction associated with that sub-unit in output
|
|
sub-unit dimensional units (MediaUnit). If this output
|
|
sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed with
|
|
management protocol operations.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series has two output bins in the base product:
|
|
a face-up bin on the back of the engine and a face-down bin on
|
|
the top of the engine. These bins are not firmware-selectable;
|
|
instead, paper is diverted to the face-down bin only if the face-up
|
|
bin is physically closed. Therefore, these bins are considered
|
|
together as the 'standard' bin.
|
|
The value returned by this object depends on the value
|
|
of prtOutputDimUnit. It is 140000 if prtOutputDimUnit is
|
|
ePtenThousandthsOfInches or 355600 if prtOutputDimUnit is ePmicrometers."
|
|
::= { prtOutputEntry 15 }
|
|
|
|
|
|
prtoutputmaxdimxfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum dimensions supported by this output sub-unit
|
|
for measurements taken ninety degrees relative to the
|
|
feed direction associated with that sub-unit in output
|
|
sub-unit dimensional units (MediaUnit). If this output
|
|
sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed with
|
|
management protocol operations.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series has two output bins in the base product:
|
|
a face-up bin on the back of the engine and a face-down bin on
|
|
the top of the engine. These bins are not firmware-selectable;
|
|
instead, paper is diverted to the face-down bin only if the face-up
|
|
bin is physically closed. Therefore, these bins are considered
|
|
together as the 'standard' bin.
|
|
The value returned by this object depends on the value
|
|
of prtOutputDimUnit. It is 85000 if prtOutputDimUnit is
|
|
ePtenThousandthsOfInches and 215900 if prtOutputDimUnit
|
|
is ePmicrometers."
|
|
::= { prtOutputEntry 16 }
|
|
|
|
|
|
prtoutputmindimfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum dimensions supported by this output sub-unit
|
|
for measurements taken parallel relative to the feed
|
|
direction associated with that sub-unit in output
|
|
sub-unit dimensional units (DimUnit). If this output
|
|
sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed with
|
|
management protocol operations.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series has two output bins in the base product:
|
|
a face-up bin on the back of the engine and a face-down bin on
|
|
the top of the engine. These bins are not firmware-selectable;
|
|
instead, paper is diverted to the face-down bin only if the face-up
|
|
bin is physically closed. Therefore, these bins are considered
|
|
together as the 'standard' bin.
|
|
The value returned by this object depends on the value
|
|
of prtOutputDimUnit. It is 50000 if prtOutputDimUnit is
|
|
ePtenThousandthsOfInches or 127000 if prtOutputDimUnit is
|
|
ePmicrometers."
|
|
::= { prtOutputEntry 17 }
|
|
|
|
|
|
prtoutputmindimxfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum dimensions supported by this output sub-unit
|
|
for measurements taken ninety degrees relative to the
|
|
feed direction associated with that sub-unit in output
|
|
sub-unit dimensional units (DimUnit). If this output
|
|
sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed with
|
|
management protocol operations.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4000 Series has two output bins in the base product:
|
|
a face-up bin on the back of the engine and a face-down bin on
|
|
the top of the engine. These bins are not firmware-selectable;
|
|
instead, paper is diverted to the face-down bin only if the face-up
|
|
bin is physically closed. Therefore, these bins are considered
|
|
together as the 'standard' bin.
|
|
The value returned by this object depends on the value
|
|
of prtOutputDimUnit. It is 30000 if prtOutputDimUnit is
|
|
ePtenThousandthsOfInches or 76200 if prtOutputDimUnit is ePmicrometers."
|
|
::= { prtOutputEntry 18 }
|
|
|
|
|
|
prtoutputstackingorder OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePunknown(2),
|
|
ePfirstToLast(3),
|
|
ePlastToFirst(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the stacking order for the
|
|
associated output sub-unit. `FirstToLast' means
|
|
that as pages are output the front of the next page is
|
|
placed against the back of the previous page.
|
|
`LasttoFirst' means that as pages are output the back
|
|
of the next page is placed against the front of the
|
|
previous page.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML OUTBINn-STACK-ORDER."
|
|
::= { prtOutputEntry 19 }
|
|
|
|
|
|
prtoutputpagedeliveryorientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePfaceUp(3),
|
|
ePfaceDown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reading surface that will be `up' when pages are
|
|
delivered to the associated output sub-unit. Values are
|
|
faceUp and faceDown. (Note: interpretation of these
|
|
values is in general context-dependent based on locale;
|
|
presentation of these values to an end-user should be
|
|
normalized to the expectations of the user).
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtOutputEntry 20 }
|
|
|
|
|
|
prtoutputbursting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePon(3),
|
|
ePoff(4),
|
|
ePnotPresent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that the outputting sub-unit
|
|
supports bursting, and if so, whether the feature is enabled.
|
|
Bursting is the process by which continuous media is separated
|
|
into individual sheets, typically by bursting along pre-formed
|
|
perforations.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtOutputEntry 21 }
|
|
|
|
|
|
prtoutputdecollating OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePon(3),
|
|
ePoff(4),
|
|
ePnotPresent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that the output supports
|
|
supports decollating, and if so, whether the feature
|
|
is enabled. Decollating is the process by which the
|
|
individual parts within a multi-part form are separated
|
|
and sorted into separate stacks for each part.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtOutputEntry 22 }
|
|
|
|
|
|
prtoutputpagecollated OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePon(3),
|
|
ePoff(4),
|
|
ePnotPresent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that the output sub-unit
|
|
supports page collation, and if so, whether the feature is
|
|
enabled. See glossary for definition of how this document defines
|
|
collation.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtOutputEntry 23 }
|
|
|
|
|
|
prtoutputoffsetstacking OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePon(3),
|
|
ePoff(4),
|
|
ePnotPresent(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates that the output supports
|
|
supports offset stacking, and if so, whether the feature is
|
|
enabled. See glossary for how Offset Stacking is defined by this
|
|
document.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtOutputEntry 24 }
|
|
|
|
|
|
prtmarkersuppliesdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description of this supply container/receptacle in the
|
|
localization specified by prtGeneralCurrentLocalization.
|
|
Refer to Standard Printer MIB for more details."
|
|
::= { prtMarkerSuppliesEntry 6 }
|
|
|
|
|
|
prtmarkersuppliesmaxcapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum capacity of this supply container/receptacle
|
|
expressed in prtMarkerSuppliesSupplyUnit. If this supply
|
|
container/receptacle can reliably sense this value, the
|
|
value is reported by the printer and is read-only;
|
|
otherwise, the value may be written (by a Remote Control
|
|
Panel or a Management Application). The value (-1) means
|
|
other and specifically indicates that the sub-unit places
|
|
no restrictions on this parameter. The value (-2) means
|
|
unknown.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4050 Series - LaserJet 4050 Series now has the same toner-mesuring feature
|
|
as LaserJet 8100 Series which utilizes the GRIN ASICS's ability to detect the
|
|
number of pixels placed on a page. The default value units are
|
|
in 10ths of a gram. A 27X toner cartridge holds 460 grams of
|
|
toner. Note :a 27A cartidge holds 303 g but we are using the
|
|
27X value."
|
|
::= { prtMarkerSuppliesEntry 8 }
|
|
|
|
|
|
prtmarkersupplieslevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current level if this supply is a container; the
|
|
remaining space if this supply is a receptacle. If this
|
|
supply container/receptacle can reliably sense this
|
|
value, the value is reported by the printer and is
|
|
read-only; otherwise, the value may be written (by a
|
|
Remote Control Panel or a Management Application). The
|
|
value (-1) means other and specifically indicates that
|
|
the sub-unit places no restrictions on this parameter.
|
|
The value (-2) means unknown. A value of (-3) means that the
|
|
printer knows that there is some supply/remaining space,
|
|
respectively.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
LaserJet 4050 Series will have a new toner-measuring feature that
|
|
utilizes the GRIN ASIC's ability to detect the amount of pixels
|
|
that have been placed on a single page. This Pixel-Counting
|
|
Gas Gauge should be able to calculate toner levels within 10%.
|
|
Because textual printing and graphics printing utilize different
|
|
pixel usage, accuracy for the counting algorithms have been
|
|
biased toward textual printing. Heavy graphics printing will
|
|
cause the cartridge to appear to be emptier than it really is.
|
|
Over time however, statistical averaging values that are kept in
|
|
NVRAM will help make the gauge more accurate according to
|
|
individual customer usage models. The new values will vary
|
|
between 0 and 4600 depending on how much toner has been
|
|
calculated to have been used."
|
|
::= { prtMarkerSuppliesEntry 9 }
|
|
|
|
|
|
prtmediapathmaxspeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum printing speed of this media path expressed in
|
|
prtMediaPathMaxSpeedUnit's. A value of (-1) implies
|
|
'other'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML PRINT-ENGINE-PERFORMANCE.
|
|
The page size for this performance is 8.5x11. The
|
|
duplex speed is based on 6 ppm."
|
|
::= { prtMediaPathEntry 4 }
|
|
|
|
|
|
prtmediapathmaxmediafeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum physical media size in the feed direction of this
|
|
media path expressed in units of measure specified by
|
|
PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited',
|
|
a value of (-2) implies 'unknown'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The value returned by this object depends on the value
|
|
of prtMediaPathMediaSizeUnit. It is 140000 if prtMediaPathMediaSizeUnit is
|
|
ePtenThousandthsOfInches or 355600 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
|
::= { prtMediaPathEntry 5 }
|
|
|
|
|
|
prtmediapathmaxmediaxfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum physical media size across the feed direction of
|
|
this media path expressed in units of measure specified by
|
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The value returned by this object depends on the value
|
|
of prtMediaPathMediaSizeUnit. It is 85000 if prtMediaPathMediaSizeUnit is
|
|
ePtenThousandthsOfInches and 215900 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
|
::= { prtMediaPathEntry 6 }
|
|
|
|
|
|
prtmediapathminmediafeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum physical media size in the feed direction of this
|
|
media path expressed in units of measure specified by
|
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The value returned by this object depends on the value
|
|
of prtMediaPathMediaSizeUnit. It is 50000 if prtMediaPathMediaSizeUnit is
|
|
ePtenThousandthsOfInches or 127000 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
|
::= { prtMediaPathEntry 7 }
|
|
|
|
|
|
prtmediapathminmediaxfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum physical media size across the feed direction of
|
|
this media path expressed in units of measure specified by
|
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
The value returned by this object depends on the value
|
|
of prtMediaPathMediaSizeUnit. It is 30000 if prtMediaPathMediaSizeUnit is
|
|
ePtenThousandthsOfInches or 76200 if prtMediaPathMediaSizeUnit is ePmicrometers."
|
|
::= { prtMediaPathEntry 8 }
|
|
|
|
|
|
file-system-max-open-files OBJECT-TYPE
|
|
SYNTAX INTEGER(32..512)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of open files allowed at one time. Opening a
|
|
file when the maximum number of files are currently open
|
|
will fail.
|
|
Additional information:
|
|
Indicates the number of open files a
|
|
personality (e.g. PCL or PostScript) is guaranteed to be
|
|
able to open before the file system runs out of file handles.
|
|
After writing this object, the printer
|
|
must be rebooted (powercycled) before the change takes effect.
|
|
This object supports any value between 32 - 512 inclusive.
|
|
If a value Less then 32 then it snaps to 32 if greater then
|
|
512 it snaps to 512.
|
|
The factory default value is dependent on the amount of
|
|
installed RAM. The default value of 32 is when
|
|
Memory <= 4MB, 128 is if the memory is > 4MB.
|
|
Performing a cold reset sets this object
|
|
back to the factory default value. Returns
|
|
<noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed.
|
|
Default for LaserJet 4000 Series/LaserJet 5000 Series is 32
|
|
Default for LaserJet 8000 Series/LaserJet 8100 Series/LaserJet 4050 Series is 128"
|
|
::= { settings-file-system 2 }
|
|
|
|
|
|
file-system-set-system-partition-writeable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the system partition to be written to. It
|
|
consists of a C structure containing the following fields:
|
|
typedef struct {
|
|
ubyte password[8];
|
|
ubyte volumenumber;
|
|
} fs_writeable_system_partition_t;
|
|
which is described below:
|
|
Bytes 0 - 7: contain the password
|
|
Byte 8 : is the volume number
|
|
MAX-ACCESS to this command is controlled by the password. If the
|
|
password supplied is incorrect the command will fail. The
|
|
volumenumber is a volume number of an existing system
|
|
partition.
|
|
Additional information:
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed.
|
|
Returns <badValue> if the password is incorrect or if
|
|
the volume requested is not present."
|
|
::= { settings-file-system 6 }
|
|
|
|
|
|
file-system-set-system-partition-readonly OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Changes a system partition to be READ-ONLY. The value is the
|
|
volume number to change. If the volume number specified is NOT
|
|
a system partition an error is returned.
|
|
Additional information:
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed.
|
|
Returns <badValue> if the volume requested
|
|
is not present."
|
|
::= { settings-file-system 7 }
|
|
|
|
|
|
file-system-delete-files OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object causes the specified filename to be
|
|
deleted, after first validating that the authentication data is
|
|
correct for the specified user ID.
|
|
The format for this object is a C structure:
|
|
typedef struct {
|
|
sint32 UserId;
|
|
uint16 AuthenticationDataLen
|
|
ubyte AuthenticationData[]
|
|
char Filename[];
|
|
} fs_delete_files_t;
|
|
which is described below:
|
|
Bytes 0 - 3: contains a user id represented as a multi-byte
|
|
value that is stored in big-endian format, where the
|
|
most significant byte occurs first.
|
|
Bytes 4 - 5 : Length of the Athentication data that follows
|
|
starting at offset 6. Stored as a multi-byte value that
|
|
is stored in big-endian format, where the most
|
|
significant byte occurs first.
|
|
Bytes 6 - 6+AuthenticationDataLen : a ubyte array
|
|
containing the Authentication data used to verify
|
|
MAX-ACCESS for this operation.
|
|
Bytes starting at offset (6+AuthenticationDataLen+1): A
|
|
null terminated character array representing the ASCII
|
|
file name to be deleted. The length of the string will
|
|
be limited by the remaining space in the object.
|
|
This string represents a fully-qualified path name which may
|
|
specify a filename or a regular expression that may match
|
|
multiple files (e.g <path>/*.exe). Access to this command is
|
|
controlled by the UserId and the authentication data. If the
|
|
UserID or authentication data supplied is incorrect the command
|
|
will fail. The device POS will specify any limitations to the
|
|
length of the filename string, what constitutes a correct user
|
|
ID, what constitutes correct authentication data, and the
|
|
significance of any return values.
|
|
Additional information:
|
|
Setting this object causes the specified filename
|
|
to be deleted, after first validating that the
|
|
authentication data is correct for the specified
|
|
user ID. This object is always present.
|
|
|
|
The format for this object is a C structure:
|
|
|
|
typedef struct {
|
|
sint32 UserId;
|
|
uint16 AuthenticationDataLen
|
|
ubyte AuthenticationData[]
|
|
char Filename[];
|
|
} fs_delete_files_t;
|
|
|
|
Bytes 0 - 3: contains a user id represented
|
|
as a multi-byte value that is stored in big-endian
|
|
format, where the most significant byte occurs first.
|
|
|
|
Bytes 4 - 5 : Length of the authentication data that
|
|
follows starting at offset 6. Stored as a multi-byte
|
|
value that is stored in big-endian format, where the
|
|
most significant byte occurs first.
|
|
|
|
Bytes 6 - 6+AuthenticationDataLen : a ubyte array
|
|
containing the authentication data used to verify
|
|
MAX-ACCESS for this operation.
|
|
|
|
Bytes starting at offset (6+AuthenticationDataLen+1):
|
|
A null terminated character array representing the
|
|
ASCII file name to be deleted. The length of the
|
|
string will be limited by the remaining space in the
|
|
object. This string represents a fully-qualified path
|
|
name which may specify a filename or a file-type regular
|
|
expression that may match multiple files (e.g.,
|
|
<path>/*.exe).
|
|
|
|
MAX-ACCESS to this command is controlled by the UserId
|
|
and the authentication data. If the UserID or
|
|
authentication data supplied is incorrect the
|
|
command will fail.
|
|
|
|
The device POS will specify any limitations to the
|
|
length of the filename string, what constitutes a
|
|
correct user ID, what constitutes correct
|
|
authentication data, and the significance of any
|
|
return values."
|
|
::= { settings-file-system 8 }
|
|
|
|
|
|
file-system-security-access-password OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object acts as a gate keeper for write access to the PML
|
|
objects FILE-SYSTEM-EXTERNAL-ACCESS-CAPABILITIES,
|
|
FILE-SYSTEM-ERASE-MODE, and FILE-SYSTEM-WIPE-DISK. The object
|
|
can be viewed as always being in one of 4 states:
|
|
State 0 --> Un-initialized:
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD is the empty
|
|
string and a pmlget operation on the object will return
|
|
the string '0'. This will be the state after an NVRAM
|
|
init which is the only way to set the object to the
|
|
empty string. It cannot be set to the empty string
|
|
through PML. In this state write access to
|
|
FILE-SYSTEM-EXTERNAL-ACCESS-CAPABILITIES,
|
|
FILE-SYSTEM-ERASE-MODE and FILE-SYSTEM-WIPE-DISK is
|
|
disabled while write access to the object itself is
|
|
enabled. A successful set operation on the object in
|
|
this state will return the string 'SET' and will result
|
|
in a transition to State 3.
|
|
State 1 --> The Password is set to a non-empty string: A
|
|
pmlget operation on the object will return the string
|
|
'1' regardless of the actual stored password value. In
|
|
this state write access to
|
|
FILE-SYSTEM-EXTERNAL-ACCESS-CAPABILITIES,
|
|
FILE-SYSTEM-ERASE-MODE and FILE-SYSTEM-WIPE-DISK is
|
|
disabled. The only string the object itself can be
|
|
successfully set to while in this state is the current
|
|
value of the password. Setting the object to its
|
|
current value causes a transition to State 2 which is
|
|
an authenticated state. The value returned from such a
|
|
set operation will be the string 'OK'.
|
|
State 2 --> The password is in an authenticated state: The
|
|
'gate' to write to the PML objects
|
|
FILE-SYSTEM-EXTERNAL-ACCESS-CAPABILITIES,
|
|
FILE-SYSTEM-ERASE-MODE, and FILE-SYSTEM-WIPE-DISK is
|
|
open. One, and only one, write operation can be
|
|
performed on one of these three objects. During such a
|
|
write operation the object itself will transition to
|
|
State 1 thus closing the gate. In State 2 a pmlset
|
|
operation on the object will result in the password
|
|
being set and a transfer to State 3. The value returned
|
|
from a set operation in this state on
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD will be 'SET'. A
|
|
pmlget operation on the object will return the string
|
|
'2' regardless of the actual password value.
|
|
State 3 --> The password was just changed: A pmlget
|
|
operation on the object will return the string '3'.
|
|
Otherwise behaviors in State 3 are exactly like in
|
|
State 1. "
|
|
::= { settings-file-system 9 }
|
|
|
|
|
|
file-system-external-access-capabilities OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to control access to the file system of the
|
|
device. It is always readable. It is writable when
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD is not the empty string,
|
|
and a successful write to that object with the current password
|
|
has preceded the write to this object. In other words, the
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD must be in the
|
|
'authenticated state' for a write on
|
|
FILE-SYSTEM-EXTERNAL-ACCESS-CAPABILITIES to succeed. After the
|
|
object has successfully been written to, it becomes read-only,
|
|
and the FILE-SYSTEM-SECURITY-ACCESS-PASSWORD object exits the
|
|
authenticated state. FILE-SYSTEM-SECURITY-ACCESS-PASSWORD must
|
|
then be written to again with the current password in order to
|
|
make another write operation on
|
|
FILE-SYSTEM-EXTERNAL-ACCESS-CAPABILITIES possible.
|
|
cDisablePJLFileSystemAccess - All file system access
|
|
through PJL will be disabled.
|
|
cDisablePMLFileSystemWrite - All file-systems-related PML
|
|
objects such as FILE-SYSTEM-DELETE-FILES or
|
|
hrPartitionLabel become read-only. For objects that are
|
|
normally write-only this means that no successful
|
|
operations can now be performed on them.
|
|
cDisableNFSFileSystemAccess - All NFS file system access
|
|
will be disabled.
|
|
cDisablePSFileSystemAccess - All file system access through
|
|
PostScript will be disabled.
|
|
cDisableEWSFileSystemAccess - All access to the file system
|
|
by the Embedded Web Server will be disabled. "
|
|
::= { settings-file-system 10 }
|
|
|
|
|
|
file-system-erase-mode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to control how file data is handled when
|
|
files are deleted. It is always readable. It is writable when
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD is the empty string or
|
|
when a write to FILE-SYSTEM-SECURITY-ACCESS-PASSWORD with the
|
|
current password has preceeded the write to the object. When
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD is not the empty string
|
|
then this object becomes read-only after a successful write to
|
|
it. FILE-SYSTEM-SECURITY-ACCESS-PASSWORD must then be written
|
|
to again with the current password in order to make another
|
|
write operation on the object possible. If the
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD is incorrectly set, this
|
|
object becomes read-only until the password is correctly set.
|
|
The logical settings for this object are:
|
|
NonSecureFastErase - When a file is deleted, only the
|
|
reference to it in the file system tables is removed.
|
|
No file data is overwritten. This is the default
|
|
setting. This is the setting when both bits in the
|
|
collection are set to 0.
|
|
SecureFastErase - File information is overwritten with
|
|
identical, random character pattern when it is deleted.
|
|
This is the setting when cEraseMode0 is set to 1 and
|
|
cEraseMode1 is set to 0.
|
|
SecureSanitizeErase - Secure, repetitive algorithm used to
|
|
overwrite all deleted file information and remove any
|
|
residual data persistence. A random character is
|
|
written to all bytes of deleted sectors. Then the
|
|
complement of that character and finally, another
|
|
random character is written. This is the setting when
|
|
cEraseMode0 is set to 0 and cEraseMode1 is set to 1.
|
|
Note that an error will be returned for an attempt to set both
|
|
bits of the collection to 1."
|
|
::= { settings-file-system 11 }
|
|
|
|
|
|
file-system-wipe-disk OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a non-leaf node which will have one leaf node
|
|
under it for each file system in the printer. The leaf nodes
|
|
will be in a 1-to-1 correspondence with the hrDeviceIndex
|
|
objects. This object specifies for each leaf node whether the
|
|
file system on the device is going to be erased according to
|
|
the setting of the FILE-SYSTEM-ERASE-MODE referenced by the
|
|
corresponding hrDeviceIndex. A file system will be overwritten
|
|
on system reboot if this object is set to 1. It will be
|
|
unchanged if this object is set to 0. If this object's value is
|
|
-1 then the file system cannot be wiped. If the file system
|
|
contains the permstore, the permstore will be saved off and
|
|
restored after the file-system wipe is completed. This object
|
|
is always readable. It is writable when
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD is the empty string or
|
|
when a write to FILE-SYSTEM-SECURITY-ACCESS-PASSWORD with the
|
|
current password has preceeded the write to the object. When
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD is not the empty string
|
|
then this object becomes read-only after a successful write to
|
|
it. FILE-SYSTEM-SECURITY-ACCESS-PASSWORD must then be written
|
|
to again with the current password in order to make another
|
|
write operation on the object possible. If the
|
|
FILE-SYSTEM-SECURITY-ACCESS-PASSWORD is incorrectly set, this
|
|
object becomes read-only until the password is correctly set."
|
|
::= { settings-file-system 12 }
|
|
|
|
|
|
file-system-wipe-disk-status OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a non-leaf node which will have one leaf node
|
|
under it for each file system in the printer. The leaf nodes
|
|
will be in a 1-to-1 correspondence with the hrDeviceIndex
|
|
objects. This object specifies for each leaf node the status of
|
|
a disk wipe in progress. A return value of -1 indicates that no
|
|
disk wipe is in progress. A return value in the range of 0 to
|
|
100 indicates the percent done for a disk wipe in progress. All
|
|
other values are illegal."
|
|
::= { settings-file-system 13 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.6.1.4
|
|
web-proxy-config-enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(0),
|
|
eOn(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This object is a OCTET STRING enumeration which the peripheral uses
|
|
to inform the JetDirect card that the Jet-Direct card embedded
|
|
web server should display the web proxy configuration settings.
|
|
The Jet Direct card web server will display the if and only if
|
|
this object is both implemented and set to eOn. A peripheral
|
|
may implement this object in order to have another host, like a
|
|
JetDirect card, include a reference to the peripheral's web
|
|
content. The peripheral will read the proxy configuration using
|
|
the XIP2 sysInfo Get methods"
|
|
::= { settings-web-server 4 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.6.1.5
|
|
ews-request-control-panel-supplies-status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " System variable EWS_REQUEST_CONTROL_PANEL_SUPPPLIES_STATUS
|
|
requires a PML interface so that WJA can directly access it
|
|
without needing EWS support for that"
|
|
::= { settings-web-server 5 }
|
|
|
|
channelnumberofchannels OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of how many print data channels the I/O
|
|
card supports.
|
|
Additional information:
|
|
This object is used by the IIO card to tell the
|
|
peripheral firmware how many logical channels will be used by
|
|
the card. This object can only be set once per physical
|
|
channel. If an attempt is made to set it a subsequent time
|
|
it is ignored and an return code of
|
|
<genErr>. is returned.
|
|
If new firmware is dynamically downloaded to the I/O
|
|
card, and if that firmware uses more logical channels, it is
|
|
necessary to reset the printer."
|
|
::= { channel 1 }
|
|
|
|
|
|
channelprinteralert OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the values of prtAlertIndex,
|
|
prtAlertSeverityLevel, prtAlertGroup,
|
|
prtAlertGroupIndex, prtAlertLocation, and prtAlertCode
|
|
for the latest critical evnet in the prtAlertTable. The
|
|
binary string is defined as following:
|
|
------------------------------------------------------
|
|
Field | Filed | Description
|
|
Offset | Length |
|
|
------------------------------------------------------
|
|
0 | 4 | the value of prtAlertIndex
|
|
4 | 4 | the value of prtAlertSeverityLevel
|
|
8 | 4 | the value of prtAlertGroup
|
|
12 | 4 | the value of prtAlertGroupIndex
|
|
16 | 4 | the value of prtAlertLocation
|
|
20 | 4 | the value of prtAlertCode
|
|
------------------------------------------------------
|
|
Each field is in Big Endian style.
|
|
Additional information:
|
|
This object is used to pass alert information
|
|
from the peripheral to the IIO card. The standard printer
|
|
MIB contains the following description:
|
|
|
|
printerAlert TRAP-TYPE
|
|
ENTERPRISE printerV1Alert
|
|
VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
|
|
prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
|
|
DESCRIPTION
|
|
'This trap is sent whenever a critical event is added to the
|
|
prtAlertTable.'
|
|
|
|
In order to provide this information in the trap packet, the
|
|
IIO card enables traps on channelPrinterAlert. When a
|
|
critical alert is generated the peripheral fills the
|
|
appropriate value into this object and sends it to the card.
|
|
This object is a structure which contains 24 bytes of data.
|
|
The structure is:
|
|
|
|
struct structAlertInfo {
|
|
sint32 prtAlertIndex;
|
|
sint32 prtAlertSeverityLevel;
|
|
sint32 prtAlertGroup;
|
|
sint32 prtAlertGroupIndex;
|
|
sint32 prtAlertLocation;
|
|
sint32 prtAlertCode;
|
|
} thisAlertData;"
|
|
::= { channel 2 }
|
|
|
|
|
|
channeltype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eChOther(1),
|
|
eChAppleTalkPAP(7),
|
|
eChLPDServer(8),
|
|
eChNetwareRPrinter(9),
|
|
eChNetwarePServer(10),
|
|
eChPort9100(11),
|
|
eChDLCLLCPort(15),
|
|
eChBidirPortTCP(38)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies the type of MIO print data channel.
|
|
Additional information:
|
|
After telling the peripheral how many logical
|
|
channels will be used, the IIO card tells the printer the
|
|
type of each of the channels. The type information is passed
|
|
using the channelType object. Values are then saved by the
|
|
peripheral and reported when users request the value of
|
|
prtChannelType."
|
|
::= { channelEntry 2 }
|
|
|
|
|
|
channelprotocolversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the protocol used on this MIO print data
|
|
channel.
|
|
Additional information:
|
|
After telling the peripheral how many logical
|
|
channels will be used, the IIO card tells the printer the
|
|
protocol version of each of the channels. The protocol
|
|
version information is passed using the
|
|
channelProtocolVersion object. Values are then saved by the
|
|
peripheral and reported when users request the value of
|
|
prtChannelProtocolVersion."
|
|
::= { channelEntry 3 }
|
|
|
|
|
|
channelstate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eChOther(1),
|
|
eChPrintDataAccecped(3),
|
|
eChNoDataAccepted(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of this print data channel. The value
|
|
determines whether control information and print data is
|
|
allowed through this channel or not.
|
|
Additional information:
|
|
After telling the peripheral how many logical
|
|
channels will be used, the IIO card tells the printer the
|
|
state of each of the channels. The state can change from
|
|
time to time. The state information is passed using the
|
|
channelState object. Values are saved by the peripheral and
|
|
reported when users request the value of prtChannelState."
|
|
::= { channelEntry 4 }
|
|
|
|
|
|
channelifindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of ifIndex which corresponds to this channel.
|
|
Additional information:
|
|
After telling the peripheral how many logical
|
|
channels will be used, the IIO card tells the printer the
|
|
value of the IfIndex for each channel. The IfIndex is used
|
|
as part of MIB-II. The values are saved by the peripheral
|
|
and reported when users request the value of
|
|
prtChannelIfIndex."
|
|
::= { channelEntry 5 }
|
|
|
|
|
|
channelstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-unit status is reported in the entries of the
|
|
principle table in the Group that represents the sub-
|
|
unit. For sub-units that report a status, there is a
|
|
status column in the table and the value of this column
|
|
is always an integer formed in the following way.
|
|
The SubUnitStatus is an integer that is the sum of 5
|
|
distinct values, Availability, Non-Critical, Critical,
|
|
On-line, and Transitioning. These values are:
|
|
Availability value
|
|
Available and Idle 0 000'b
|
|
Available and Standby 2 010'b
|
|
Available and Active 4 100'b
|
|
Available and Busy 6 110'b
|
|
Unavailable and OnRequest 1 001'b
|
|
Unavailable because Broken 3 011'b
|
|
Unknown 5 101'b
|
|
Non-Critical
|
|
No Non-Critical Alerts 0
|
|
Non-Critical Alerts 8
|
|
Critical
|
|
No Critical Alerts 0
|
|
Critical Alerts 16
|
|
On-Line
|
|
Intended state is On-Line 0
|
|
Intended state is Off-Line 32
|
|
Transitioning
|
|
At intended state 0
|
|
Transitioning to intended state 64
|
|
Additional information:
|
|
After telling the peripheral how many logical
|
|
channels will be used, the IIO card tells the printer the
|
|
status of each of the channels. The status can change from
|
|
time to time. The status information is passed using the
|
|
channelStatus object. Values are saved by the peripheral and
|
|
reported when users request the value of prtChannelStatus."
|
|
::= { channelEntry 6 }
|
|
|
|
|
|
channelinformation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auxiliary information to allow a printing application to
|
|
use the channel for data submission to the printer. An
|
|
application capable of using a specific PrtChannelType
|
|
should be able to use the combined information from the
|
|
prtChannelInformation and other channel and interface
|
|
group objects to 'bootstrap' its use of the channel.
|
|
prtChannelInformation is not intended to provide a
|
|
general channel description, nor to provide information
|
|
that is available once the channel is in use. The
|
|
encoding and interpretation of the prtChannelInformation
|
|
object is specific to channel type. The description of
|
|
each PrtChannelType enum value for which
|
|
prtChannelInformation is defined specifies the
|
|
appropriate encoding and interpretation, including
|
|
interaction with other objects. For channel types that
|
|
do not specify a prtChannelInformation value, its value
|
|
shall be null (0 length). When a new PrtChannelType
|
|
enumeration value is registered, its accompanying
|
|
description must specify the encoding and interpretation
|
|
of the prtChannelInformation value for the channel type.
|
|
prtChannelInformation semantics for an existing
|
|
PrtChannelType may be added or amended in the same
|
|
manner as described in section 2.4.1 for type 2
|
|
enumeration values. The prtChannelInformation specifies
|
|
values for a collection of channel attributes,
|
|
represented as text according to the following rules:
|
|
1. The prtChannelInformation is coded in the NVT ASCII
|
|
character set. It is not affected by localization.
|
|
2. The prtChannelInformation is a list of entries
|
|
representing the attribute values. Each entry consists
|
|
of the following items, in order:
|
|
a. a keyword, composed of alphabetic characters (A-
|
|
Z, a-z), that identifies a channel attribute,
|
|
b. an Equals Sign (=) to delimit the keyword,
|
|
c. a data value, consisting of NVT ASCII graphics
|
|
characters (codes 32-126),
|
|
d. a Line Feed character (code 10) to delimit the
|
|
data value.
|
|
No other characters shall be present. Keywords are
|
|
case-sensitive. Conventionally, keywords are
|
|
capitalized (including each word of a multi-word
|
|
keyword), and, since they occupy space in the
|
|
prtChannelInformation, they are kept short.
|
|
3. If a channel attribute has multiple values, it is
|
|
represented by multiple entries with the same keyword,
|
|
each specifying one value. Otherwise, there shall be at
|
|
most one entry for each attribute.
|
|
4. By default, entries may appear in any order. If
|
|
there are ordering constraints for particular entries,
|
|
these must be specified in their definitions.
|
|
5. The prtChannelInformation value may represent
|
|
information that is not normally coded in textual form,
|
|
or that is coded in a character set other than NVT
|
|
ASCII. In these cases, whatever symbolic representation
|
|
is conventionally used for the information should be
|
|
used for encoding the prtChannelInformation. (For
|
|
instance, a binary port value might be represented as a
|
|
decimal number, Unicode would be represented in UTF-8
|
|
format.)
|
|
6. For each PrtChannelType for which
|
|
prtChannelInformation entries are defined, the
|
|
descriptive text associated with the PrtChannelType
|
|
enumeration value shall specify the following
|
|
information for each entry:
|
|
Title: Brief description phrase, e.g.: 'Port
|
|
name,'Service Name,'
|
|
Keyword: The keyword value, eg: 'Port,' 'Service'
|
|
Syntax: The encoding of the entry value, if it
|
|
cannot be directly represented by NVT ASCII,
|
|
Status: 'Mandatory,' 'Optional,' or 'Conditionally
|
|
Mandatory,'
|
|
Multiplicity: 'Single' or 'Multiple,' to indicate
|
|
whether the entry may be present multiple times,
|
|
Description: Description of the use of the entry,
|
|
other information required to complete the definition
|
|
(e.g.: ordering contstraints, interactions between
|
|
entries).
|
|
Applications that interpret prtChannelInformation should
|
|
ignore unrecognized entries, so they are not affected if
|
|
new entry types are added.
|
|
Additional information:
|
|
After telling the peripheral how many logical
|
|
channels will be used, the IIO card tells the printer the
|
|
value of the information value of each of the channels. The
|
|
information is auxiliary information used in conjunction with
|
|
the channel Type."
|
|
::= { channelEntry 7 }
|
|
|
|
|
|
channel-bytes-sent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The low order 31 bits of the number of bytes sent from
|
|
the printer to the host on this logical channel."
|
|
::= { channel-entry 2 }
|
|
|
|
|
|
channel-bytes-received OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The low order 31 bits of the number of bytes received by
|
|
the printer from the host on this logical channel."
|
|
::= { channel-entry 3 }
|
|
|
|
|
|
channel-io-errors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The low order 31 bits of the number of I/O errors which
|
|
have occured on this logical channel."
|
|
::= { channel-entry 4 }
|
|
|
|
|
|
channel-jobs-received OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The low order 31 bits of the number of print jobs which
|
|
have been received on this logical channel."
|
|
::= { channel-entry 5 }
|
|
|
|
|
|
channel-mio OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the MIO card associated with this logical
|
|
channel. If this logical channel is not associated with
|
|
an MIO card a zero is returned. The value returned for
|
|
each logical channel is the MIO card's physical slot
|
|
number. The list of supported values should be
|
|
documented in the device POS.
|
|
Additional information:
|
|
The value returned will be zero for channels 1..3.
|
|
If an MIOA card is installed, channels 4..10 will
|
|
return a value of one or two.
|
|
If an MIOB card is installed, channels 11..17 will
|
|
return a value of one or two but not the
|
|
same as channels 4..10.
|
|
When two IIO cards are installed, the value
|
|
returned by any channel 4..17 may change after the
|
|
printer is power cycled."
|
|
::= { channel-entry 6 }
|
|
|
|
|
|
prtchanneltype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePchSerialPort(3),
|
|
ePchIEEE1284Port(5),
|
|
ePchAppleTalkPAP(7),
|
|
ePchNetwareRPrinter(9),
|
|
ePchNetwarePServer(10),
|
|
ePchBidirPortTCP(38),
|
|
ePchDLCLLCPort(15)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of this print data channel. This
|
|
object provides the linkage to ChannelType-specific
|
|
groups that may (conceptually) extend the prtChannelTable
|
|
with additional details about that channel.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object, in conjunction with prtChannelProtocolVersion,
|
|
replaces the PML object PORTn-DESCRIPTION.
|
|
IIO based channels provide their own values."
|
|
::= { prtChannelEntry 2 }
|
|
|
|
|
|
prtchannelprotocolversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the protocol used on this
|
|
channel. The format used for version numbering depends
|
|
on prtChannelType.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object, in conjunction with prtChannelType,
|
|
replaces the PML object PORTn-DESCRIPTION.
|
|
IIO-based channels provide their own values.
|
|
The channel 1 value includes (separated by semi colons)
|
|
different aspectsof the spec: electrical: logical; and
|
|
physical connector."
|
|
::= { prtChannelEntry 3 }
|
|
|
|
|
|
prtchannelcurrentjobcntllangindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtInterpreterIndex corresponding to the
|
|
Control Language Interpreter for this channel. This
|
|
interpreter defines the syntax used for control
|
|
functions, such as querying or changing environment
|
|
variables and identifying job boundaries (e.g. PJL,
|
|
PostScript, NPAP). Must be 1 or greater.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
This object points to the PJL language. It is
|
|
read-only because PJL is the printer's only job
|
|
control language."
|
|
::= { prtChannelEntry 4 }
|
|
|
|
|
|
prtchanneldefaultpagedesclangindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of prtInterpreterIndex corresponding to the
|
|
Page Description Language Interpreter for this channel.
|
|
This interpreter defines the default Page Description
|
|
Language interpreter to be used for the print data unless
|
|
the Control Language is used to select a specific
|
|
interpreter (e.g., PCL, PostScript Language,
|
|
auto-sense). Must be 1 or greater.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
Replaces PML DEFAULT-PDL. The default points to the
|
|
automatic language switcher. If this object is changed
|
|
for one channel, all channels will be changed."
|
|
::= { prtChannelEntry 5 }
|
|
|
|
|
|
prtchannelstate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePprintDataAccepted(3),
|
|
ePnoDataAccepted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of this print data channel. The value determines
|
|
whether control information and print data is allowed through
|
|
this channel or not.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
IIO-based channels provide their own values for this
|
|
object. The base-printer's ports always report a value of
|
|
ePprintDataAccepted.
|
|
If the printer is offline, that is detected by reading the
|
|
Host Resources General Printer Status objects, not by reading
|
|
this object."
|
|
::= { prtChannelEntry 6 }
|
|
|
|
|
|
prtchannelifindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of ifIndex (in the ifTable; see the interface
|
|
section of MIB-2/RFC 1213) which corresponds to this channel.
|
|
When more than one row of the ifTable is relevant, this is
|
|
the index of the row representing the topmost layer in the
|
|
interface hierarchy. A value of zero indicates that no
|
|
interface is associated with this channel.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
IIO-based channels provide their own values for this
|
|
object."
|
|
::= { prtChannelEntry 7 }
|
|
|
|
|
|
prtchannelstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of the channel.
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
IIO-based channels provide their own values for this
|
|
object."
|
|
::= { prtChannelEntry 8 }
|
|
|
|
|
|
prtchannelinformation OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auxiliary information to allow a printing application to use
|
|
the channel for data submission to the printer. An application
|
|
capable of using a specific PrtChannelType should be able to use
|
|
the combined information from the prtChannelInformation and
|
|
other channel and interface group objects to 'bootstrap' its use
|
|
of the channel. prtChannelInformation is not intended to
|
|
provide a general channel description, nor to provide
|
|
information that is available once the channel is in use.
|
|
The encoding and interpretation of the prtChannelInformation
|
|
object is specific to channel type. The description of each
|
|
PrtChannelType enum value for which prtChannelInformation is
|
|
defined specifies the appropriate encoding and interpretation,
|
|
including interaction with other objects. For channel types
|
|
that do not specify a prtChannelInformation value, its value
|
|
shall be null (0 length).
|
|
When a new PrtChannelType enumeration value is registered, its
|
|
accompanying description must specify the encoding and
|
|
interpretation of the prtChannelInformation value for the
|
|
channel type. prtChannelInformation semantics for an existing
|
|
PrtChannelType may be added or amended in the same manner as
|
|
described in section 2.4.1 for type 2 enumeration values.
|
|
The prtChannelInformation specifies values for a collection of
|
|
channel attributes, represented as text according to the
|
|
following rules:
|
|
1. The prtChannelInformation is coded in the NVT ASCII
|
|
character set. It is not affected by localization.
|
|
2. The prtChannelInformation is a list of entries representing
|
|
the attribute values. Each entry consists of the following
|
|
items, in order:
|
|
a. a keyword, composed of alphabetic characters (A-Z,
|
|
a-z), that identifies a channel attribute,
|
|
b. an Equals Sign (=) to delimit the keyword,
|
|
c. a data value, consisting of NVT ASCII graphics
|
|
characters (codes 32-126),
|
|
d. a Line Feed character (code 10) to delimit the data
|
|
value.
|
|
No other characters shall be present.
|
|
Keywords are case-sensitive. Conventionally, keywords are
|
|
capitalized (including each word of a multi-word keyword),
|
|
and, since they occupy space in the prtChannelInformation,
|
|
they are kept short.
|
|
3. If a channel attribute has multiple values, it is
|
|
represented by multiple entries with the same keyword, each
|
|
specifying one value. Otherwise, there shall be at most
|
|
one entry for each attribute.
|
|
4. By default, entries may appear in any order. If there are
|
|
ordering constraints for particular entries, these must be
|
|
specified in their definitions.
|
|
5. The prtChannelInformation value may represent information
|
|
that is not normally coded in textual form, or that is coded
|
|
in a character set other than NVT ASCII. In these cases,
|
|
whatever symbolic representation is conventionally used for
|
|
the information should be used for encoding the
|
|
prtChannelInformation. (For instance, a binary port value
|
|
might be represented as a decimal number, Unicode would
|
|
be represented in UTF-8 format.)
|
|
6. For each PrtChannelType for which prtChannelInformation
|
|
entries are defined, the descriptive text associated with the
|
|
PrtChannelType enumeration value shall specify the following
|
|
information for each entry:
|
|
Title: Brief description phrase, e.g.: 'Port name',
|
|
'Service Name',
|
|
Keyword: The keyword value, eg: 'Port', 'Service'
|
|
Syntax: The encoding of the entry value, if it
|
|
cannot be directly represented by NVT ASCII,
|
|
Status: 'Mandatory', 'Optional', or 'Conditionally
|
|
Mandatory',
|
|
Multiplicity: 'Single' or 'Multiple', to indicate whether
|
|
the entry may be present multiple times,
|
|
Description: Description of the use of the entry, other
|
|
information required to complete the
|
|
definition (e.g.: ordering contstraints,
|
|
interactions between entries).
|
|
Applications that interpret prtChannelInformation should ignore
|
|
unrecognized entries, so they are not affected if new entry
|
|
types are added.
|
|
|
|
Refer to Standard Printer MIB for more details.
|
|
Additional information:
|
|
IIO-based channels provide their own values for this
|
|
object."
|
|
::= { prtChannelEntry 9 }
|
|
|
|
|
|
job-info-outbins-used OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which output bins this job has delivered
|
|
printed pages to. The last OID field for this dynamic
|
|
object contains the job ID.
|
|
Additional information:
|
|
The bins designated by this collection include
|
|
the printer's own output bins as well as the `logical output
|
|
bins' associated with any attached external paper handling
|
|
devices. (The mapping of the physical output bins of an
|
|
external paper handling device to its `logical output bins'
|
|
depends on the usage mode of the device. For instance, in
|
|
`mailbox mode', there is one-to-one correspondence of
|
|
`logical output bins' to physical bins, whereas in `stacker
|
|
mode', one `logical output bin' may map to several physical
|
|
bins.)
|
|
|
|
Although LaserJet 5000 Series and LaserJet 4000 Series both come with two output
|
|
bins -- a face-down bin on the top of the device and a
|
|
face-up bin at the back of the device -- firmware will not
|
|
provide a means of selecting between the two, nor will it
|
|
report which of the two gets used. For this reason, bit 0
|
|
(cOutbin1) of this collection is being used to designate
|
|
both of these bins together."
|
|
::= { job-info 20 }
|
|
|
|
|
|
job-info-physical-outbins-used OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which physical output bins this job has
|
|
delivered printed pages to. The last OID field for this
|
|
dynamic object contains the job ID.
|
|
Additional information:
|
|
The output bins designated by the bits of
|
|
this collection include the standard output bin(s) plus the
|
|
physical bins of attached external paper handling devices.
|
|
The configuration (if any) of external paper handling devices
|
|
will determine the mapping of individual bits in this
|
|
collection to the physical bins of the devices.
|
|
For LaserJet 4050 Series (LaserJet 4050), the cOutbin1 is used for Face Down
|
|
bin, cOutbin2 is used for Face Up bin, and 3-15 are used for
|
|
the 13 optional output bins (12 plus an extension to the Face
|
|
Up bin) for backwards compatibility with LaserJet 8000 Series/LaserJet 8100 Series and
|
|
forwards compatibility with future printers. However, since LaserJet 4050 Series
|
|
cannot distinguish output going to the Face Up or Face Down
|
|
bin in the firmware because the diverter can only be moved
|
|
manually, bit 0 (cOutbin1) is being used to designate
|
|
both of these bits together. If an external paper handling
|
|
output device is connected, then bit 2 (cOutbin3) will
|
|
represent the device's first output bin (and so on)."
|
|
::= { job-info 22 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.4.1.1.
|
|
printed-modes-mono-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of mono pages printed in this fuser mode"
|
|
::= { printed-modes-usage 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.4.1.3.
|
|
printed-modes-color-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of color pages printed in this fuser mode"
|
|
::= { printed-modes-usage 3 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.4.1.5.
|
|
printed-modes-total-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " The total count for pages printed in this fuser mode"
|
|
::= { printed-modes-usage 5 }
|
|
|
|
printed-media-simplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..930576247)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of simplex pages printed in this media
|
|
size.
|
|
Additional information:
|
|
The 5 usage (simplex/duplex count, simplex/duplex click
|
|
charge and paper size total) objects described here and
|
|
below detail the usage for the printer for each paper
|
|
size defined in the PCL Implementor's Guide and in the
|
|
Media Size Table in the hpmib.txt. The OID binding is
|
|
based on the click attribute and paper size.
|
|
For example:
|
|
|
|
The format for the OID is as follows:
|
|
|
|
3.4.1.5.x.y
|
|
<-----> | |
|
|
| | \
|
|
/ | paper size
|
|
/ \
|
|
PRINTER-CLICK_TOTALS ROOT \
|
|
OID click attribute 1..5
|
|
|
|
x values are 1..5:
|
|
|
|
1) simplex count
|
|
2) simplex click charge
|
|
3) duplex count
|
|
4) duplex click charge
|
|
5) printer or scanner paper size total (i.e. depends if the
|
|
root OID is referrring to the printer or scanner).
|
|
|
|
y : paper size as defined in the Media Size Table in the
|
|
hpmib.txt "
|
|
::= { printed-media-usage 1 }
|
|
|
|
|
|
printed-media-simplex-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Charge for each simplex page printed in this media
|
|
size."
|
|
::= { printed-media-usage 2 }
|
|
|
|
|
|
printed-media-duplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER(0..930576247)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of duplex pages printed in this media
|
|
size."
|
|
::= { printed-media-usage 3 }
|
|
|
|
|
|
printed-media-duplex-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Charge for each duplex page printed in this media size.
|
|
Additional information:
|
|
The click charges for duplex printed media."
|
|
::= { printed-media-usage 4 }
|
|
|
|
|
|
printed-media-total-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total charge for pages printed in this media size."
|
|
::= { printed-media-usage 5 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.1.7.
|
|
printed-media-combined-total OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Total number of letter equivalently weighted pages both color
|
|
and mono combined with this printer"
|
|
::= { printed-media-usage 7 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.1.10.
|
|
printed-media-dimplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of mono dimplex pages printed in this media size.
|
|
A dimplex page is one that has been printed in duplex mode but
|
|
the back side is blank. Dimplex pages occur when the printer
|
|
firmware inserts a blank page in order to complete a duplexed
|
|
job which is sent to the printer with an odd number of pages"
|
|
::= { printed-media-usage 10 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.1.11.
|
|
printed-media-combined-simplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of simplex pages printed on this media size"
|
|
::= { printed-media-usage 11 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.1.12.
|
|
printed-media-combined-duplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of duplex pages printed on this media size"
|
|
::= { printed-media-usage 12 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.1.15
|
|
impression-based-duplex-count-supported OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " The object is used to get the information on new duplex
|
|
counting mechanism. With this new mechanism the Duplex count
|
|
would represent actual Duplex count and not half of the count.
|
|
eTrue means feature is available for the user"
|
|
::= { printed-media-usage 15 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.5.1.1.
|
|
source-tray-usage-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of pages printed from this source tray"
|
|
::= { source-tray-usage 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.6.1.1.
|
|
destination-bin-usage-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of pages printed to this destination bin"
|
|
::= { destination-bin-usage 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.2.
|
|
print-meter-usage-threshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " A value indicating the threshold value for this category of
|
|
pages. The device POS will indicate the units of measure for
|
|
this threshold value"
|
|
::= { print-meter-usage 2 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.3.
|
|
print-meter-print-quality OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePrintQualityMono(1),
|
|
ePrintQualityGood(2),
|
|
ePrintQualityBest(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " This enumeration describes the selected print quality for this
|
|
category of printed pages
|
|
"
|
|
::= { print-meter-usage 3 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.4
|
|
print-meter-simplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of simplex pages printed for this category of
|
|
printed pages"
|
|
::= { print-meter-usage 4 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.5
|
|
print-meter-duplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of duplex pages printed for this category of
|
|
printed pages"
|
|
::= { print-meter-usage 5 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.6
|
|
print-meter-total-charge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of simplex plus duplex pages printed multiplied by
|
|
the unit charge for each given media size for this category of
|
|
printed pages"
|
|
::= { print-meter-usage 6 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.7
|
|
print-meter-dimplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of dimplex pages printed for this category of
|
|
printed pages"
|
|
::= { print-meter-usage 7 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.8.
|
|
print-meter-simplex-total OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of simplex pages printed for this category of
|
|
printed pages"
|
|
::= { print-meter-usage 8 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.9.
|
|
print-meter-duplex-total OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of duplex pages printed for this category of
|
|
printed pages"
|
|
::= { print-meter-usage 9 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.10.
|
|
print-meter-category-total OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of simplex plus duplex pages printed for this
|
|
category of printed pages"
|
|
::= { print-meter-usage 10 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.1.14.11.
|
|
print-meter-dimplex-total OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of dimplex pages printed for this category of
|
|
printed pages"
|
|
::= { print-meter-usage 11 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.3.1.1.
|
|
printed-media-color-simplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of color simplex pages printed in this media
|
|
size"
|
|
::= { printed-media-color-usage 1 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.3.1.3.
|
|
printed-media-color-duplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of color duplex pages printed in this media size"
|
|
::= { printed-media-color-usage 3 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.3.1.5.
|
|
printed-media-color-total-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " The total count for color pages printed in this media size"
|
|
::= { printed-media-color-usage 5 }
|
|
|
|
-- 1.3.6.1.4.1.11.2.3.9.4.2.1.1.16.3.1.6.
|
|
printed-media-color-dimplex-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Total number of color dimplex pages printed in this media size.
|
|
A color dimplex page is a color page that has been printed in
|
|
duplex mode but the back side is blank. Dimplex pages occur
|
|
when the printer firmware inserts a blank page in order to
|
|
complete a duplexed job which is sent to the printer with an
|
|
odd number of pages"
|
|
::= { printed-media-color-usage 6 }
|
|
|
|
firmware-download-write-status-supported OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides information on whether the printer has the
|
|
ability to communicate the write-status of the firmware
|
|
download while the download is taking place."
|
|
::= { firmware-download 1 }
|
|
|
|
|
|
firmware-download-write-time OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the design of the firmware-download implementation does not
|
|
allow PML interaction during the download process, this value
|
|
provides an estimation of the time where the printer will not
|
|
be able to engage in PML communication.
|
|
Additional information:
|
|
If the design of the firmware-download
|
|
implementation does not allow PML interaction during
|
|
the download process, this value provides an
|
|
estimation of the time where the printer will not be
|
|
able to engage in PML communication. The calculated
|
|
time is expected to be 140 secs. However, this time
|
|
may increase as high as 280 secs as the flash part
|
|
nears the maximum flash count."
|
|
::= { firmware-download 2 }
|
|
|
|
|
|
firmware-download-write-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tells the number of times that firmware has been downloaded to
|
|
the flash part.
|
|
Additional information:
|
|
Tells the number of times that firmware has been
|
|
downloaded to the flash part. The default value will
|
|
vary depending on how many times the firmware is
|
|
rolled before shipping."
|
|
::= { firmware-download 3 }
|
|
|
|
|
|
firmware-download-current-state OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eIdle(1),
|
|
eReceivingImage(2),
|
|
eReceivedImageError(3),
|
|
eVerifyingImage(4),
|
|
eVerifiedImageError(5),
|
|
eWritingImage(6),
|
|
eWritingImageError(7),
|
|
eDownloadComplete(8),
|
|
eOKtoShutDown(9),
|
|
eCancelDownload(10),
|
|
eShuttingDown(11)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the current or last reportable state of the firmware
|
|
download process. The current state may not necessarily be the
|
|
current state, but could be the post-mortem state."
|
|
::= { firmware-download 4 }
|
|
|
|
|
|
firmware-download-maximum-write-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports the manufacturer specified number of times that
|
|
firmware can be downloaded to the flash part. A value of -1
|
|
means that there is no limit. A value of 0 means that
|
|
downloading firmware is not permitted by this part. Any other
|
|
positive integer value corresponds to the number of times that
|
|
firmware can be downloaded to the flash part.
|
|
Additional information:
|
|
Reports the manufacturer specified number of
|
|
times that firmware can be downloaded to the flash
|
|
part. A value of -1 means that there is no limit.
|
|
A value of 0 means that downloading firmware is not
|
|
permitted by this part. Any other positive integer
|
|
value corresponds to the number of times that
|
|
firmware can be downloaded to the flash part. The
|
|
current maximum write count is 500. This may change
|
|
as flash technology evolves."
|
|
::= { firmware-download 5 }
|
|
|
|
|
|
firmware-download-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This returns the name of the printer. This should match the
|
|
name in the header of the upgrade image being sent to the flash
|
|
part. If the name does not match with the name returned then
|
|
the image that we are attempting to download does not upgrade
|
|
the printer firmware.
|
|
Additional information:
|
|
This object returns the HP name of the printer.
|
|
This should match what is in the PJL header of the RFU job
|
|
Web Jet Admin uses this to ensure the printer is available
|
|
to be upgraded."
|
|
::= { firmware-download 6 }
|
|
|
|
|
|
firmware-download-version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object will return a string value representing the current
|
|
revision of firmware that the printer is operating with. This
|
|
is used to determine if code needs to be upgraded when an
|
|
firmware bundle comes in, in an upgrade job.
|
|
Additional information:
|
|
Web Jet Admin uses the version string that is returned to
|
|
determine what peices of an RFU bundle need to be upgraded
|
|
when an RFU job is being built. This objects will return
|
|
the version string of the printer."
|
|
::= { firmware-download 7 }
|
|
|
|
|
|
upgradable-devices-write-status-supported OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides information on whether the upgradable
|
|
device has the ability to communicate the write-status of the
|
|
upgrade while the upgrade is taking place."
|
|
::= { upgradable-devices 1 }
|
|
|
|
|
|
upgradable-devices-write-time OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the design of the device upgrade implementation does not
|
|
allow PML interaction during the download process, this value
|
|
provides an estimation of the time where the device will not
|
|
be able to engage in PML communication. The time returned
|
|
will depend upon what device is attempting to be upgraded."
|
|
::= { upgradable-devices 2 }
|
|
|
|
|
|
upgradable-devices-write-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tells the number of times that firmware for device X has been
|
|
downloaded to the flash part. The default value will vary
|
|
depending on how many times the firmware is rolled before
|
|
shipping."
|
|
::= { upgradable-devices 3 }
|
|
|
|
|
|
upgradable-devices-current-state OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eIdle(1),
|
|
eReceivedImage(2),
|
|
eReceivedImageError(3),
|
|
eVerifiedImage(4),
|
|
eVerifiedImageError(5),
|
|
eWritingImage(6),
|
|
eWritingImageError(7),
|
|
eUpgradeComplete(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the current or last reportable state of the device
|
|
upgrade process. The current state may not necessarily be the
|
|
current state, but could be the post-mortem state."
|
|
::= { upgradable-devices 4 }
|
|
|
|
|
|
upgradable-devices-max-write-count OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports the manufacturer specified number of times that
|
|
firmware for device X can be downloaded to the flash part. A
|
|
value of -1 means that there is no limit. A value of 0 means
|
|
that downloading firmware is not permitted by this part. Any
|
|
other positive integer value corresponds to the number of
|
|
times that the firmware for device X can be downloaded to the
|
|
flash part. The current maximum write count is 500. This may
|
|
change as flash technology evolves."
|
|
::= { upgradable-devices 5 }
|
|
|
|
|
|
upgradable-devices-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This returns the name of the upgradable device. This should
|
|
match the name in the header of the upgrade image being sent
|
|
to the flash part. If the name does not match with any of the
|
|
names returned then the device that we are attempting to
|
|
upgrade is unavailable for upgrading.
|
|
Additional information:
|
|
This object returns the HP name of the printer and the upgradable
|
|
devices. There is one Name object per upgradable device.
|
|
This should match what is in the PJL header of the RFU job
|
|
Web Jet Admin uses this to ensure the printer or device is
|
|
available to be upgraded."
|
|
::= { upgradable-devices 6 }
|
|
|
|
|
|
upgradable-devices-version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object will return a string value representing the
|
|
current revision of firmware that device X is operating with.
|
|
This is used to determine if code needs to be upgraded when an
|
|
firmware bundle comes in, in an upgrade job.
|
|
Additional information:
|
|
Web Jet Admin uses the version string that is returned to
|
|
determine what peices of an RFU bundle need to be upgraded
|
|
when an RFU job is being built. This internal object will
|
|
return the current version string of the printer or device
|
|
that it corresponds to."
|
|
::= { upgradable-devices 7 }
|
|
|
|
|
|
remote-upgrade-enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables or disables the ability to upgrade the firmware
|
|
associated with any device that is available to be upgraded.
|
|
This will be set to on or off at the RFU level in that if this
|
|
mode is on any available device can be upgraded and if this
|
|
mode is off none of the devices can be upgraded. There is not
|
|
an individual mode for each device. Trying to set this to a
|
|
value other than eOn or eOff will cause an UnsupportedValue
|
|
error to occur."
|
|
::= { upgradable-devices 8 }
|
|
|
|
|
|
END
|
|
|