1073 lines
34 KiB
Plaintext
1073 lines
34 KiB
Plaintext
-- *****************************************************************
|
|
-- RBN-PVC-MIB Redback PVC MIB
|
|
--
|
|
-- Copyright (c) 2000-2004, 2006, 2007 RedBack Networks, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
RBN-PVC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
|
|
TEXTUAL-CONVENTION, RowStatus,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
|
|
rbnMgmt
|
|
FROM RBN-SMI
|
|
|
|
RbnSlot, RbnPort, RbnCircuitHandle,
|
|
RbnVidOrUntagged
|
|
FROM RBN-TC;
|
|
|
|
rbnPvcMib MODULE-IDENTITY
|
|
LAST-UPDATED "200710291700Z" -- Oct 29, 2007
|
|
ORGANIZATION "Redback Networks, Inc."
|
|
CONTACT-INFO
|
|
" RedBack Networks, Inc.
|
|
|
|
Postal: 300 Holger Way
|
|
San Jose, CA 95134-1362
|
|
USA
|
|
|
|
Phone: +1 408 750 5000
|
|
Fax: +1 408 750 5599
|
|
|
|
E-mail: mib-info@redback.com"
|
|
DESCRIPTION
|
|
"Defines the objects necessary to support the management of
|
|
ATM, Frame Relay and IEEE 802.1Q permanent virtual circuits
|
|
(PVC)."
|
|
|
|
REVISION "200710291700Z" -- Oct 29, 2007
|
|
DESCRIPTION
|
|
"Added new encaps type to TEXTUAL-CONVENTION
|
|
RbnAtmEncapsulation."
|
|
|
|
REVISION "200405211700Z" -- May 21, 2004
|
|
DESCRIPTION
|
|
"Added new encaps type to TEXTUAL-CONVENTION
|
|
RbnFrameRelayEncapsulation.
|
|
Added new encaps type to TEXTUAL-CONVENTION
|
|
RbnAtmEncapsulation."
|
|
|
|
REVISION "200303171700Z" -- March 17, 2003
|
|
DESCRIPTION
|
|
"The following changes were made to manage the configuration
|
|
of 802.1Q PVCs on Ethernet ports, ATM circuits and Frame
|
|
Relay circuits:
|
|
Updated MODULE-IDENTITY.
|
|
Added TEXTUAL-CONVENTION RbnDot1qEncapsulation.
|
|
Added three new tables:
|
|
rbnDot1qPvcOnEthConfigTable
|
|
rbnDot1qPvcOnAtmConfigTable
|
|
rbnDot1qPvcOnFrConfigTable
|
|
Added new compliance module and groups:
|
|
rbnPvcCompliance3
|
|
rbnDot1qPvcOnEthGroup
|
|
rbnDot1qPvcOnAtmGroup
|
|
rbnDot1qPvcOnFrGroup"
|
|
|
|
REVISION "200212201700Z" -- December 20, 2002
|
|
DESCRIPTION
|
|
"To support categorization of circuit types, to provide
|
|
an object to link entries in the rbnAtmPvcConfigTable and
|
|
the rbnFrameRelayPvcConfigTable to the rbnBindTable from
|
|
the RBN-BIND-MIB, and to provide the capability to clear
|
|
subscribers from circuits, witness the following changes:
|
|
Updated MODULE-IDENTITY.
|
|
Added TEXTUAL-CONVENTION RbnPvcCircuitType.
|
|
Added new objects to rbnAtmPvcConfigTable:
|
|
rbnAtmPvcCircuitType
|
|
rbnAtmPvcCircuitHandle
|
|
rbnAtmPvcClearCircuit
|
|
Added new objects to rbnFrameRelayPvcConfigTable:
|
|
rbnFrameRelayPvcCircuitType
|
|
rbnFrameRelayPvcCircuitHandle
|
|
rbnFrameRelayPvcClearCircuit
|
|
Added new MODULE-COMPLIANCE and OBJECT-GROUPs:
|
|
rbnPvcCompliance2
|
|
rbnAtmPvcGroup2
|
|
rbnFrameRelayPvcGroup2"
|
|
|
|
REVISION "200211130000Z" -- November 13, 2002
|
|
DESCRIPTION
|
|
"Moved RbnSlot and RbnPort definitions to Redback Textual
|
|
Convention MIB (RBN-TC)."
|
|
|
|
REVISION "200205231700Z" -- May 23, 2002
|
|
DESCRIPTION
|
|
"Updated CONTACT-INFO clause in MODULE-IDENTITY.
|
|
Added new CLIPs encaps type to the RbnFrameRelayEncapsulation
|
|
and RbnAtmEncapsulation TEXTUAL-CONVENTION definitions."
|
|
|
|
REVISION "200105091700Z" -- May 9, 2001
|
|
DESCRIPTION
|
|
"Updated range on RbnSlot, RbnPort, and rbnAtmPvcVpi."
|
|
|
|
REVISION "200102101700Z" -- February 10, 2001
|
|
DESCRIPTION
|
|
"Removed all references to padding which was an obsoleted
|
|
attribute of PVC circuits."
|
|
|
|
REVISION "200008301200Z" -- August 30, 2000
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { rbnMgmt 7 }
|
|
|
|
rbnPvcMIBObjects OBJECT IDENTIFIER ::= { rbnPvcMib 1 }
|
|
|
|
rbnPvcMIBConformance OBJECT IDENTIFIER ::= { rbnPvcMib 2 }
|
|
|
|
rbnPvcMIBNotifications OBJECT IDENTIFIER ::= { rbnPvcMib 3 }
|
|
|
|
--
|
|
-- Textual Conventions
|
|
--
|
|
RbnFrameRelayEncapsulation ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation types supported by frame relay."
|
|
SYNTAX INTEGER {
|
|
auto1490(1), -- auto detect bridge or routed encapsulation
|
|
bridge1490(2), -- bridged 1490
|
|
multi1490(3), -- 1490 bridge or PPPoE encapsulation
|
|
route1490(4), -- Routed 1490 encapsulation
|
|
l2tp(5), -- l2tp encapsulation
|
|
l2tpVcMuxed(6), -- vc-muxed l2tp encapsulation
|
|
ppp(7), -- PPP encapsulation
|
|
pppAuto(8), -- Automatically detect PPP encapsulation
|
|
pppOverEthernet(9), -- PPP over Ethernet (PPPOE) encapsulation
|
|
dot1q1490(10), -- 802.1Q over bridged 1490
|
|
clips1490(11), -- clientless IP 1490
|
|
pppAutoNopoe(12) -- pppAuto without pppoe
|
|
}
|
|
|
|
RbnAtmEncapsulation ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation types supported by ATM."
|
|
SYNTAX INTEGER {
|
|
unknown(0), -- unknown encapsulation
|
|
auto1483(1), -- auto detect bridge or routed encapsulation
|
|
bridge1483(2), -- bridged 1483
|
|
multi1483(3), -- 1483 bridge or PPPoE encapsulation
|
|
route1483(4), -- Routed 1483 encapsulation
|
|
l2tp(5), -- l2tp encapsulation
|
|
l2tpVcMuxed(6), -- vc-muxed l2tp encapsulation
|
|
ppp(7), -- PPP encapsulation
|
|
pppAuto(8), -- Automatically detect PPP encapsulation
|
|
pppOverEthernet(9), -- PPP over Ethernet (PPPOE) encapsulation
|
|
pppSerial(10), -- SERIAL PPP encaps used in non compliant
|
|
-- configurations
|
|
pppNlpid(11), -- NLPID PPP encaps
|
|
pppLlc(12), -- LLC/SNAP PPP encaps per RFC 2364
|
|
pppVcMuxed(13), -- vc-based mux encaps per RFC-2364
|
|
raw(14), -- raw encaps
|
|
dot1q1483(15), -- 802.1Q over bridged 1483
|
|
clips1483(16), -- clientless IP 1483
|
|
pppAutoNopoe(17), -- pppAuto without pppoe
|
|
cell(18) -- cell
|
|
}
|
|
|
|
RbnDot1qEncapsulation ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation types supported by 802.1Q PVC."
|
|
SYNTAX INTEGER {
|
|
unknown(0), -- unknown encapsulation
|
|
ipOverEthernet(1), -- IP over Ethernet encapsulation
|
|
dot1qMulti(2), -- PPPoE, IPoE, or IPv6oE encapsulation
|
|
pppOverEthernet(3), -- PPP over Ethernet encapsulation
|
|
dot1qRaw(4), -- dot1qRaw over Ethernet encapsulation
|
|
dot1qClips(5), -- dot1qClips over Ethernet encapsulation
|
|
dot1qTunnelMulti(6), -- PPPoE, IPoE, or IPv6oE encapsulation
|
|
dot1qTunnelPppOverEthernet(7), -- PPP over Ethernet encapsulation
|
|
dot1qTunnelRaw(8), -- dot1qTunnelRaw over Ethernet encapsulation
|
|
dot1qTunnelClips(9) -- do1tqTunnelclips over Ethernet encapsulation
|
|
}
|
|
|
|
RbnPvcCircuitType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PVC circuit type."
|
|
SYNTAX INTEGER {
|
|
explicit(1), -- a single explicit circuit
|
|
explicitRange(2), -- an explicit circuit range
|
|
onDemandRange(3), -- an ondemand circuit range
|
|
protection(4) -- an APS protection circuit
|
|
}
|
|
|
|
|
|
--
|
|
-- ATM PVC Configuration Group
|
|
--
|
|
-- This table supports the identification, addition, configuration and
|
|
-- deletion of ATM PVCs.
|
|
--
|
|
|
|
rbnAtmPvcConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbnAtmPvcConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the objects which identify and configure
|
|
ATM PVCs."
|
|
::= { rbnPvcMIBObjects 1 }
|
|
|
|
rbnAtmPvcConfigEntry OBJECT-TYPE
|
|
SYNTAX RbnAtmPvcConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the rbnAtmPvcConfigTable."
|
|
INDEX {
|
|
rbnAtmPvcSlot,
|
|
rbnAtmPvcPort,
|
|
rbnAtmPvcVpi,
|
|
rbnAtmPvcVci
|
|
}
|
|
::= { rbnAtmPvcConfigTable 1 }
|
|
|
|
RbnAtmPvcConfigEntry ::=
|
|
SEQUENCE {
|
|
rbnAtmPvcSlot RbnSlot,
|
|
rbnAtmPvcPort RbnPort,
|
|
rbnAtmPvcVpi Unsigned32,
|
|
rbnAtmPvcVci Unsigned32,
|
|
rbnAtmPvcProfileName SnmpAdminString,
|
|
rbnAtmPvcEncapsulation RbnAtmEncapsulation,
|
|
rbnAtmPvcRowStatus RowStatus,
|
|
rbnAtmPvcCircuitType RbnPvcCircuitType,
|
|
rbnAtmPvcCircuitHandle RbnCircuitHandle,
|
|
rbnAtmPvcClearCircuit TruthValue
|
|
}
|
|
|
|
rbnAtmPvcSlot OBJECT-TYPE
|
|
SYNTAX RbnSlot
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis slot number"
|
|
::= { rbnAtmPvcConfigEntry 1 }
|
|
|
|
rbnAtmPvcPort OBJECT-TYPE
|
|
SYNTAX RbnPort
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number"
|
|
::= { rbnAtmPvcConfigEntry 2 }
|
|
|
|
rbnAtmPvcVpi OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Path Identifier for the PVC."
|
|
::= { rbnAtmPvcConfigEntry 3 }
|
|
|
|
rbnAtmPvcVci OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Channel Identifier for the PVC."
|
|
::= { rbnAtmPvcConfigEntry 4 }
|
|
|
|
rbnAtmPvcProfileName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(1..63))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The profile name to use with the PVC."
|
|
::= { rbnAtmPvcConfigEntry 5 }
|
|
|
|
rbnAtmPvcEncapsulation OBJECT-TYPE
|
|
SYNTAX RbnAtmEncapsulation
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation to use with the PVC."
|
|
::= { rbnAtmPvcConfigEntry 6 }
|
|
|
|
rbnAtmPvcRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status for creating, modifying, or deleting an entry
|
|
in the table."
|
|
::= { rbnAtmPvcConfigEntry 8 }
|
|
|
|
rbnAtmPvcCircuitType OBJECT-TYPE
|
|
SYNTAX RbnPvcCircuitType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PVC circuit type. With respect to this mib
|
|
object, only those entries whose rbnAtmPvcCircuitType
|
|
has a value 'explicit' may be removed by setting
|
|
rbnAtmPvcRowStatus equal to 'destroy'. A set
|
|
operation with rbnAtmPvcRowStatus equal to 'destroy'
|
|
on any row with rbnAtmPvcCircuitType not equal to
|
|
'explicit' will result in an INCONSISTENT_VALUE_ERROR."
|
|
DEFVAL { explicit }
|
|
::= { rbnAtmPvcConfigEntry 9 }
|
|
|
|
rbnAtmPvcCircuitHandle OBJECT-TYPE
|
|
SYNTAX RbnCircuitHandle
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used internally to uniquely identify
|
|
a circuit. The value of this object may be used to
|
|
correlate entries with those in the rbnBindTable defined
|
|
in the RBN-BIND-MIB."
|
|
::= { rbnAtmPvcConfigEntry 10 }
|
|
|
|
rbnAtmPvcClearCircuit OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this object is true(1), the system will clear active
|
|
subscriber sessions on the specified circuit. When false(2),
|
|
there is no action taken. This object can only be written
|
|
when the conceptual row exists.
|
|
|
|
When this object is set to true(1) and the encapsulation
|
|
of the circuit is bridged or routed, e.g. bridge1483(2) or
|
|
route1483(4), subscribers will re-authenticate after
|
|
being cleared."
|
|
DEFVAL { false }
|
|
::= { rbnAtmPvcConfigEntry 11 }
|
|
|
|
--
|
|
-- Frame Relay PVC Configuration Group
|
|
--
|
|
-- This table supports the identification, addition, configuration and
|
|
-- deletion of frame relay PVCs.
|
|
--
|
|
|
|
rbnFrameRelayPvcConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbnFrameRelayPvcConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the objects which identify and configure
|
|
Frame Relay PVCs."
|
|
::= { rbnPvcMIBObjects 2 }
|
|
|
|
rbnFrameRelayPvcConfigEntry OBJECT-TYPE
|
|
SYNTAX RbnFrameRelayPvcConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the rbnFrameRelayPvcConfigTable."
|
|
INDEX {
|
|
rbnFrameRelayPvcSlot,
|
|
rbnFrameRelayPvcPort,
|
|
rbnFrameRelayPvcChannel,
|
|
rbnFrameRelayPvcDLCI
|
|
}
|
|
::= { rbnFrameRelayPvcConfigTable 1 }
|
|
|
|
RbnFrameRelayPvcConfigEntry ::=
|
|
SEQUENCE {
|
|
rbnFrameRelayPvcSlot RbnSlot,
|
|
rbnFrameRelayPvcPort RbnPort,
|
|
rbnFrameRelayPvcChannel Unsigned32,
|
|
rbnFrameRelayPvcDLCI Unsigned32,
|
|
rbnFrameRelayPvcProfileName SnmpAdminString,
|
|
rbnFrameRelayPvcEncapsulation RbnFrameRelayEncapsulation,
|
|
rbnFrameRelayPvcRowStatus RowStatus,
|
|
rbnFrameRelayPvcCircuitType RbnPvcCircuitType,
|
|
rbnFrameRelayPvcCircuitHandle RbnCircuitHandle,
|
|
rbnFrameRelayPvcClearCircuit TruthValue
|
|
}
|
|
|
|
rbnFrameRelayPvcSlot OBJECT-TYPE
|
|
SYNTAX RbnSlot
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis slot number"
|
|
::= { rbnFrameRelayPvcConfigEntry 1 }
|
|
|
|
rbnFrameRelayPvcPort OBJECT-TYPE
|
|
SYNTAX RbnPort
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number"
|
|
::= { rbnFrameRelayPvcConfigEntry 2 }
|
|
|
|
rbnFrameRelayPvcChannel OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The channel number"
|
|
::= { rbnFrameRelayPvcConfigEntry 3 }
|
|
|
|
rbnFrameRelayPvcDLCI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Data Link Connection Identifier"
|
|
::= { rbnFrameRelayPvcConfigEntry 4 }
|
|
|
|
rbnFrameRelayPvcProfileName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(1..63))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The profile name to use with the PVC."
|
|
::= { rbnFrameRelayPvcConfigEntry 5 }
|
|
|
|
rbnFrameRelayPvcEncapsulation OBJECT-TYPE
|
|
SYNTAX RbnFrameRelayEncapsulation
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation to use with the PVC."
|
|
::= { rbnFrameRelayPvcConfigEntry 6 }
|
|
|
|
rbnFrameRelayPvcRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status for creating, modifying, or deleting an entry
|
|
in the table."
|
|
::= { rbnFrameRelayPvcConfigEntry 8 }
|
|
|
|
rbnFrameRelayPvcCircuitType OBJECT-TYPE
|
|
SYNTAX RbnPvcCircuitType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PVC circuit type. With respect to this mib
|
|
object, only those entries whose rbnFrameRelayPvcCircuitType
|
|
has a value 'explicit' may be removed by setting
|
|
rbnFrameRelayPvcRowStatus equal to 'destroy'. A set
|
|
operation with rbnFrameRelayPvcRowStatus equal to 'destroy'
|
|
on any row with rbnFrameRelayPvcCircuitType not equal to
|
|
'explicit' will result in an INCONSISTENT_VALUE_ERROR."
|
|
DEFVAL { explicit }
|
|
::= { rbnFrameRelayPvcConfigEntry 9 }
|
|
|
|
rbnFrameRelayPvcCircuitHandle OBJECT-TYPE
|
|
SYNTAX RbnCircuitHandle
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used internally to uniquely identify
|
|
a circuit. The value of this object may be used to
|
|
correlate entries with those in the rbnBindTable defined
|
|
in the RBN-BIND-MIB."
|
|
::= { rbnFrameRelayPvcConfigEntry 10 }
|
|
|
|
rbnFrameRelayPvcClearCircuit OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this object is true(1), the system will clear active
|
|
subscriber sessions on the specified circuit. When false(2),
|
|
there is no action taken. This object can only be written
|
|
when the conceptual row exists.
|
|
|
|
When this object is set to true(1) and the encapsulation
|
|
of the circuit is bridged or routed, e.g. bridge1490(2) or
|
|
route1490(4), subscribers will re-authenticate after
|
|
being cleared."
|
|
::= { rbnFrameRelayPvcConfigEntry 11 }
|
|
|
|
--
|
|
-- 802.1Q PVC on Ethernet Configuration Group
|
|
--
|
|
-- This table supports the identification, addition, configuration and
|
|
-- deletion of IEEE 802.1Q PVCs on Ethernet ports.
|
|
--
|
|
|
|
rbnDot1qPvcOnEthConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbnDot1qPvcOnEthConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the objects which identify and configure
|
|
IEEE 802.1Q PVCs on Ethernet ports."
|
|
::= { rbnPvcMIBObjects 3 }
|
|
|
|
rbnDot1qPvcOnEthConfigEntry OBJECT-TYPE
|
|
SYNTAX RbnDot1qPvcOnEthConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the rbnDot1qPvcOnEthConfigTable."
|
|
INDEX {
|
|
rbnDot1qPvcOnEthSlot,
|
|
rbnDot1qPvcOnEthPort,
|
|
rbnDot1qPvcOnEthVlanId
|
|
}
|
|
::= { rbnDot1qPvcOnEthConfigTable 1 }
|
|
|
|
RbnDot1qPvcOnEthConfigEntry ::=
|
|
SEQUENCE {
|
|
rbnDot1qPvcOnEthSlot RbnSlot,
|
|
rbnDot1qPvcOnEthPort RbnPort,
|
|
rbnDot1qPvcOnEthVlanId RbnVidOrUntagged,
|
|
rbnDot1qPvcOnEthRowStatus RowStatus,
|
|
rbnDot1qPvcOnEthProfileName SnmpAdminString,
|
|
rbnDot1qPvcOnEthEncapsulation RbnDot1qEncapsulation,
|
|
rbnDot1qPvcOnEthCircuitType RbnPvcCircuitType,
|
|
rbnDot1qPvcOnEthCircuitHandle RbnCircuitHandle,
|
|
rbnDot1qPvcOnEthClearCircuit TruthValue
|
|
}
|
|
|
|
rbnDot1qPvcOnEthSlot OBJECT-TYPE
|
|
SYNTAX RbnSlot
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis slot number."
|
|
::= { rbnDot1qPvcOnEthConfigEntry 1 }
|
|
|
|
rbnDot1qPvcOnEthPort OBJECT-TYPE
|
|
SYNTAX RbnPort
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number."
|
|
::= { rbnDot1qPvcOnEthConfigEntry 2 }
|
|
|
|
rbnDot1qPvcOnEthVlanId OBJECT-TYPE
|
|
SYNTAX RbnVidOrUntagged
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IEEE 802.1Q Virtual LAN (VLAN) tag value."
|
|
::= { rbnDot1qPvcOnEthConfigEntry 3 }
|
|
|
|
rbnDot1qPvcOnEthRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status for creating, modifying, or deleting an entry
|
|
in the table."
|
|
::= { rbnDot1qPvcOnEthConfigEntry 4 }
|
|
|
|
rbnDot1qPvcOnEthProfileName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(1..63))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The profile name to use with the PVC."
|
|
::= { rbnDot1qPvcOnEthConfigEntry 5 }
|
|
|
|
rbnDot1qPvcOnEthEncapsulation OBJECT-TYPE
|
|
SYNTAX RbnDot1qEncapsulation
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation to use with the PVC."
|
|
::= { rbnDot1qPvcOnEthConfigEntry 6 }
|
|
|
|
rbnDot1qPvcOnEthCircuitType OBJECT-TYPE
|
|
SYNTAX RbnPvcCircuitType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PVC circuit type. With respect to this mib object,
|
|
only those entries whose rbnDot1qPvcOnEthCircuitType
|
|
has a value 'explicit' may be removed by setting
|
|
rbnDot1qPvcOnEthRowStatus equal to 'destroy'. A set
|
|
operation with rbnDot1qPvcOnEthRowStatus equal to 'destroy'
|
|
on any row with rbnDot1qPvcOnEthCircuitType not equal to
|
|
'explicit' will result in an INCONSISTENT_VALUE_ERROR."
|
|
DEFVAL { explicit }
|
|
::= { rbnDot1qPvcOnEthConfigEntry 7 }
|
|
|
|
rbnDot1qPvcOnEthCircuitHandle OBJECT-TYPE
|
|
SYNTAX RbnCircuitHandle
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used internally to uniquely identify
|
|
a circuit. The value of this object may be used to
|
|
correlate entries with those in the rbnBindTable defined
|
|
in the RBN-BIND-MIB."
|
|
::= { rbnDot1qPvcOnEthConfigEntry 8 }
|
|
|
|
rbnDot1qPvcOnEthClearCircuit OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this object is true(1), the system will clear active
|
|
subscriber sessions on the specified circuit. When false(2),
|
|
there is no action taken. This object can only be written
|
|
when the conceptual row exists."
|
|
DEFVAL { false }
|
|
::= { rbnDot1qPvcOnEthConfigEntry 9 }
|
|
|
|
--
|
|
-- 802.1Q PVC Configuration On ATM Circuits Group
|
|
--
|
|
-- This table supports the identification, addition, configuration and
|
|
-- deletion of IEEE 802.1Q PVCs on ATM circuits.
|
|
--
|
|
|
|
rbnDot1qPvcOnAtmConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbnDot1qPvcOnAtmConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the objects which identify and configure
|
|
IEEE 802.1Q PVCs on ATM circuits."
|
|
::= { rbnPvcMIBObjects 4 }
|
|
|
|
rbnDot1qPvcOnAtmConfigEntry OBJECT-TYPE
|
|
SYNTAX RbnDot1qPvcOnAtmConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the rbnDot1qPvcOnAtmConfigTable."
|
|
INDEX {
|
|
rbnDot1qPvcOnAtmSlot,
|
|
rbnDot1qPvcOnAtmPort,
|
|
rbnDot1qPvcOnAtmVpi,
|
|
rbnDot1qPvcOnAtmVci,
|
|
rbnDot1qPvcOnAtmVlanId
|
|
}
|
|
::= { rbnDot1qPvcOnAtmConfigTable 1 }
|
|
|
|
RbnDot1qPvcOnAtmConfigEntry ::=
|
|
SEQUENCE {
|
|
rbnDot1qPvcOnAtmSlot RbnSlot,
|
|
rbnDot1qPvcOnAtmPort RbnPort,
|
|
rbnDot1qPvcOnAtmVpi Unsigned32,
|
|
rbnDot1qPvcOnAtmVci Unsigned32,
|
|
rbnDot1qPvcOnAtmVlanId RbnVidOrUntagged,
|
|
rbnDot1qPvcOnAtmRowStatus RowStatus,
|
|
rbnDot1qPvcOnAtmProfileName SnmpAdminString,
|
|
rbnDot1qPvcOnAtmEncapsulation RbnDot1qEncapsulation,
|
|
rbnDot1qPvcOnAtmCircuitType RbnPvcCircuitType,
|
|
rbnDot1qPvcOnAtmCircuitHandle RbnCircuitHandle,
|
|
rbnDot1qPvcOnAtmClearCircuit TruthValue
|
|
}
|
|
|
|
rbnDot1qPvcOnAtmSlot OBJECT-TYPE
|
|
SYNTAX RbnSlot
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis slot number."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 1 }
|
|
|
|
rbnDot1qPvcOnAtmPort OBJECT-TYPE
|
|
SYNTAX RbnPort
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 2 }
|
|
|
|
rbnDot1qPvcOnAtmVpi OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Path Identifier for the PVC."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 3 }
|
|
|
|
rbnDot1qPvcOnAtmVci OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Virtual Channel Identifier for the PVC."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 4 }
|
|
|
|
rbnDot1qPvcOnAtmVlanId OBJECT-TYPE
|
|
SYNTAX RbnVidOrUntagged
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IEEE 802.1Q Virtual LAN (VLAN) tag value."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 5 }
|
|
|
|
rbnDot1qPvcOnAtmRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status for creating, modifying, or deleting an entry
|
|
in the table."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 6 }
|
|
|
|
rbnDot1qPvcOnAtmProfileName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(1..63))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The profile name to use with the PVC."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 7 }
|
|
|
|
rbnDot1qPvcOnAtmEncapsulation OBJECT-TYPE
|
|
SYNTAX RbnDot1qEncapsulation
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation to use with the PVC."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 8 }
|
|
|
|
rbnDot1qPvcOnAtmCircuitType OBJECT-TYPE
|
|
SYNTAX RbnPvcCircuitType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PVC circuit type. With respect to this mib object,
|
|
only those entries whose rbnDot1qPvcOnAtmCircuitType
|
|
has a value 'explicit' may be removed by setting
|
|
rbnDot1qPvcOnAtmRowStatus equal to 'destroy'. A set
|
|
operation with rbnDot1qPvcOnAtmRowStatus equal to 'destroy'
|
|
on any row with rbnDot1qPvcOnAtmCircuitType not equal to
|
|
'explicit' will result in an INCONSISTENT_VALUE_ERROR."
|
|
DEFVAL { explicit }
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 9 }
|
|
|
|
rbnDot1qPvcOnAtmCircuitHandle OBJECT-TYPE
|
|
SYNTAX RbnCircuitHandle
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used internally to uniquely identify
|
|
a circuit. The value of this object may be used to
|
|
correlate entries with those in the rbnBindTable defined
|
|
in the RBN-BIND-MIB."
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 10 }
|
|
|
|
rbnDot1qPvcOnAtmClearCircuit OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this object is true(1), the system will clear active
|
|
subscriber sessions on the specified circuit. When false(2),
|
|
there is no action taken. This object can only be written
|
|
when the conceptual row exists."
|
|
DEFVAL { false }
|
|
::= { rbnDot1qPvcOnAtmConfigEntry 11 }
|
|
|
|
--
|
|
-- 802.1Q PVC Configuration On Frame Relay Circuits Group
|
|
--
|
|
-- This table supports the identification, addition, configuration and
|
|
-- deletion of IEEE 802.1Q PVCs on Frame Relay circuits. In addition,
|
|
-- clearing subscribers from circuits is supported.
|
|
--
|
|
|
|
rbnDot1qPvcOnFrConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbnDot1qPvcOnFrConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the objects which identify and configure
|
|
IEEE 802.1Q PVCs on ATM circuits."
|
|
::= { rbnPvcMIBObjects 5 }
|
|
|
|
rbnDot1qPvcOnFrConfigEntry OBJECT-TYPE
|
|
SYNTAX RbnDot1qPvcOnFrConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the rbnDot1qPvcOnFrConfigTable."
|
|
INDEX {
|
|
rbnDot1qPvcOnFrSlot,
|
|
rbnDot1qPvcOnFrPort,
|
|
rbnDot1qPvcOnFrChannel,
|
|
rbnDot1qPvcOnFrDLCI,
|
|
rbnDot1qPvcOnFrVlanId
|
|
}
|
|
::= { rbnDot1qPvcOnFrConfigTable 1 }
|
|
|
|
RbnDot1qPvcOnFrConfigEntry ::=
|
|
SEQUENCE {
|
|
rbnDot1qPvcOnFrSlot RbnSlot,
|
|
rbnDot1qPvcOnFrPort RbnPort,
|
|
rbnDot1qPvcOnFrChannel Unsigned32,
|
|
rbnDot1qPvcOnFrDLCI Unsigned32,
|
|
rbnDot1qPvcOnFrVlanId RbnVidOrUntagged,
|
|
rbnDot1qPvcOnFrRowStatus RowStatus,
|
|
rbnDot1qPvcOnFrProfileName SnmpAdminString,
|
|
rbnDot1qPvcOnFrEncapsulation RbnDot1qEncapsulation,
|
|
rbnDot1qPvcOnFrCircuitType RbnPvcCircuitType,
|
|
rbnDot1qPvcOnFrCircuitHandle RbnCircuitHandle,
|
|
rbnDot1qPvcOnFrClearCircuit TruthValue
|
|
}
|
|
|
|
rbnDot1qPvcOnFrSlot OBJECT-TYPE
|
|
SYNTAX RbnSlot
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis slot number."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 1 }
|
|
|
|
rbnDot1qPvcOnFrPort OBJECT-TYPE
|
|
SYNTAX RbnPort
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 2 }
|
|
|
|
rbnDot1qPvcOnFrChannel OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The channel number."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 3 }
|
|
|
|
rbnDot1qPvcOnFrDLCI OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Data Link Connection Identifier."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 4 }
|
|
|
|
rbnDot1qPvcOnFrVlanId OBJECT-TYPE
|
|
SYNTAX RbnVidOrUntagged
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IEEE 802.1Q Virtual LAN (VLAN) tag value."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 5 }
|
|
|
|
rbnDot1qPvcOnFrRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status for creating, modifying, or deleting an entry
|
|
in the table."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 6 }
|
|
|
|
rbnDot1qPvcOnFrProfileName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(1..63))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The profile name to use with the PVC."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 7 }
|
|
|
|
rbnDot1qPvcOnFrEncapsulation OBJECT-TYPE
|
|
SYNTAX RbnDot1qEncapsulation
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation to use with the PVC."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 8 }
|
|
|
|
rbnDot1qPvcOnFrCircuitType OBJECT-TYPE
|
|
SYNTAX RbnPvcCircuitType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PVC circuit type. With respect to this mib object,
|
|
only those entries whose rbnDot1qPvcOnFrCircuitType
|
|
has a value 'explicit' may be removed by setting
|
|
rbnDot1qPvcOnFrRowStatus equal to 'destroy'. A set
|
|
operation with rbnDot1qPvcOnFrRowStatus equal to 'destroy'
|
|
on any row with rbnDot1qPvcOnFrCircuitType not equal to
|
|
'explicit' will result in an INCONSISTENT_VALUE_ERROR."
|
|
DEFVAL { explicit }
|
|
::= { rbnDot1qPvcOnFrConfigEntry 9 }
|
|
|
|
rbnDot1qPvcOnFrCircuitHandle OBJECT-TYPE
|
|
SYNTAX RbnCircuitHandle
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used internally to uniquely identify
|
|
a circuit. The value of this object may be used to
|
|
correlate entries with those in the rbnBindTable defined
|
|
in the RBN-BIND-MIB."
|
|
::= { rbnDot1qPvcOnFrConfigEntry 10 }
|
|
|
|
rbnDot1qPvcOnFrClearCircuit OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this object is true(1), the system will clear active
|
|
subscriber sessions on the specified circuit. When false(2),
|
|
there is no action taken. This object can only be written
|
|
when the conceptual row exists."
|
|
DEFVAL { false }
|
|
::= { rbnDot1qPvcOnFrConfigEntry 11 }
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
rbnPvcCompliances OBJECT IDENTIFIER ::= { rbnPvcMIBConformance 1 }
|
|
rbnPvcGroups OBJECT IDENTIFIER ::= { rbnPvcMIBConformance 2 }
|
|
|
|
rbnPvcCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP entities which implement
|
|
the RBN-PVC-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
rbnAtmPvcGroup,
|
|
rbnFrameRelayPvcGroup
|
|
}
|
|
::= { rbnPvcCompliances 1 }
|
|
|
|
rbnPvcCompliance2 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP entities which implement
|
|
the RBN-PVC-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
rbnAtmPvcGroup2,
|
|
rbnFrameRelayPvcGroup2
|
|
}
|
|
::= { rbnPvcCompliances 2 }
|
|
|
|
rbnPvcCompliance3 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP entities which implement
|
|
the RBN-PVC-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
rbnAtmPvcGroup2,
|
|
rbnFrameRelayPvcGroup2,
|
|
rbnDot1qPvcOnEthGroup,
|
|
rbnDot1qPvcOnAtmGroup,
|
|
rbnDot1qPvcOnFrGroup
|
|
}
|
|
::= { rbnPvcCompliances 3 }
|
|
|
|
--
|
|
-- groupings
|
|
--
|
|
|
|
rbnAtmPvcGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rbnAtmPvcProfileName,
|
|
rbnAtmPvcEncapsulation,
|
|
rbnAtmPvcRowStatus
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"the collection of objects which represent the ATM PVC."
|
|
::= { rbnPvcGroups 1 }
|
|
|
|
rbnFrameRelayPvcGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rbnFrameRelayPvcProfileName,
|
|
rbnFrameRelayPvcEncapsulation,
|
|
rbnFrameRelayPvcRowStatus
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"the collection of objects which represent the FrameRelay PVC."
|
|
::= { rbnPvcGroups 2 }
|
|
|
|
rbnAtmPvcGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
rbnAtmPvcProfileName,
|
|
rbnAtmPvcEncapsulation,
|
|
rbnAtmPvcRowStatus,
|
|
rbnAtmPvcCircuitType,
|
|
rbnAtmPvcCircuitHandle,
|
|
rbnAtmPvcClearCircuit
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which represent the ATM PVC."
|
|
::= { rbnPvcGroups 3 }
|
|
|
|
rbnFrameRelayPvcGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
rbnFrameRelayPvcProfileName,
|
|
rbnFrameRelayPvcEncapsulation,
|
|
rbnFrameRelayPvcRowStatus,
|
|
rbnFrameRelayPvcCircuitType,
|
|
rbnFrameRelayPvcCircuitHandle,
|
|
rbnFrameRelayPvcClearCircuit
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects which represent the FrameRelay PVC."
|
|
::= { rbnPvcGroups 4 }
|
|
|
|
rbnDot1qPvcOnEthGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rbnDot1qPvcOnEthRowStatus,
|
|
rbnDot1qPvcOnEthProfileName,
|
|
rbnDot1qPvcOnEthEncapsulation,
|
|
rbnDot1qPvcOnEthCircuitType,
|
|
rbnDot1qPvcOnEthCircuitHandle,
|
|
rbnDot1qPvcOnEthClearCircuit
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information specific
|
|
to IEEE 802.1Q PVCs on Ethernet ports."
|
|
::= { rbnPvcGroups 5 }
|
|
|
|
rbnDot1qPvcOnAtmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rbnDot1qPvcOnAtmRowStatus,
|
|
rbnDot1qPvcOnAtmProfileName,
|
|
rbnDot1qPvcOnAtmEncapsulation,
|
|
rbnDot1qPvcOnAtmCircuitType,
|
|
rbnDot1qPvcOnAtmCircuitHandle,
|
|
rbnDot1qPvcOnAtmClearCircuit
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information specific
|
|
to IEEE 802.1Q PVCs on ATM circuits."
|
|
::= { rbnPvcGroups 6 }
|
|
|
|
rbnDot1qPvcOnFrGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rbnDot1qPvcOnFrRowStatus,
|
|
rbnDot1qPvcOnFrProfileName,
|
|
rbnDot1qPvcOnFrEncapsulation,
|
|
rbnDot1qPvcOnFrCircuitType,
|
|
rbnDot1qPvcOnFrCircuitHandle,
|
|
rbnDot1qPvcOnFrClearCircuit
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information specific
|
|
to IEEE 802.1Q PVCs on Frame Relay circuits."
|
|
::= { rbnPvcGroups 7 }
|
|
|
|
END
|