-- Copyright 2014 Electroline Equipment Inc
|
|
-- All Rights Reserved
|
|
--
|
|
--*****************************************************************************
|
|
-- Filename: ELECTROLINE-COMMON-TEST.mib
|
|
-- Author: Alain Leclerc
|
|
-- Creation Date: 2014.01.14
|
|
--*****************************************************************************
|
|
-- Description:
|
|
--
|
|
-- This file contains the SNMPv2 MIB definition of the test branch
|
|
-- for the electroline products.
|
|
--
|
|
--*****************************************************************************
|
|
-- Revision History:
|
|
-- 2014.01.14 Alain Leclerc First Draft
|
|
--*****************************************************************************
|
|
|
|
ELECTROLINE-COMMON-TEST-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32
|
|
FROM SNMPv2-SMI
|
|
RowStatus, TruthValue, DateAndTime
|
|
FROM SNMPv2-TC
|
|
commonPrivate
|
|
FROM ELECTROLINE-COMMON-ROOT-MIB
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB; -- RFC 3411;
|
|
|
|
TenthCelsius ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-1"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This data type represents Temperature that are normally
|
|
expressed in Celsius. Units are in tenths of a Celsius;
|
|
for example, 5.1 Celsius will be represented as 51."
|
|
SYNTAX Integer32
|
|
|
|
swMode OBJECT-TYPE
|
|
SYNTAX INTEGER {normal(0), testOnly(1), cmOnly(2), scanFeatureInDiagnosticMode(30)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB can be used to control the software activity of the DVM
|
|
- In Normal mode, the device performs as programmed.
|
|
- In testOnly mode, the device stops all monitoring activity and
|
|
populates only the test and calibration MIBS.
|
|
- In cmOnly mode, the device performs as a plain cable modem. All
|
|
other features are disabled.
|
|
|
|
The value of this MIB is stored in non-volatile memory.
|
|
|
|
Note that the MODE jumper previously used to access testOnly
|
|
mode, now is used as an override for the swMode.
|
|
To have access to set this mode, the brcm factory mib must be enable.
|
|
Otherwise, read only"
|
|
::= { commonPrivate 1 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- * Definition of dvmTest Sub-groups
|
|
-- ****************************************************************************
|
|
prodTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Group of production tests objects related to all models"
|
|
::= { commonPrivate 2 }
|
|
|
|
prodInventory OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Group of inventory objects related to all models"
|
|
::= { prodTest 1}
|
|
|
|
prodInvHwType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware Model Identification Number. This information is used by the
|
|
software to differentiate the hardware platform on which it is running.
|
|
For example, the HMS022 compatible version and the legacy version of the DHT
|
|
have different hardware types."
|
|
::= { prodInventory 1 }
|
|
|
|
prodInvHwMinorRev OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware Revision Identification Number, representing the PCB version
|
|
and / or the assembly modification level."
|
|
::= { prodInventory 2 }
|
|
|
|
prodInvHwMajorRev OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This information is used to represent a family of hardware revisions.
|
|
Major functional changes will trigger a modification of this value"
|
|
::= { prodInventory 3 }
|
|
|
|
prodInvHwDrvRev OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This information is used to track any changes in the manufacturing process
|
|
not covered by a PCB/Assembly revision and that have an impact on the drivers.
|
|
"
|
|
::= { prodInventory 4 }
|
|
|
|
prodModelNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the private electroline model number.
|
|
Displayed in human-readable format."
|
|
::= { prodInventory 5 }
|
|
|
|
--*****************************************************************************
|
|
-- * MANUFACTURING INVENTORY DATA
|
|
-- *
|
|
-- * This section contains additional manufacturing process related information
|
|
-- * for tracking purposes.
|
|
--*****************************************************************************
|
|
prodManufacturingInfo OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Electroline Private sub-tree to access manufacturing information"
|
|
::= { prodInventory 10 }
|
|
|
|
prodMfcDateTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Date and time when this unit was tested (in a string format)."
|
|
::= { prodManufacturingInfo 1 }
|
|
|
|
prodMfcTestSwVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version of the test station on which this unit was tested."
|
|
::= { prodManufacturingInfo 2 }
|
|
|
|
prodConfiguration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Electroline production configuration branch"
|
|
::= { prodTest 2}
|
|
|
|
-- ****************************************************************************
|
|
-- * Definition of Configuration Sub-groups
|
|
-- ****************************************************************************
|
|
prodFormatFlash OBJECT-TYPE
|
|
SYNTAX INTEGER {format(1)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This mib triggers the formating of the last blocks of the two
|
|
flash banks. These section contains the dht logs"
|
|
::= {prodConfiguration 1}
|
|
|
|
prodDocsisMode OBJECT-TYPE
|
|
SYNTAX INTEGER {docsis(1), euroDocsis(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" 1 Set the Dht in DOCSIS mode
|
|
2 Set the Dht in EuroDOCSIS mode
|
|
DEFAULT = 1
|
|
"
|
|
::= {prodConfiguration 2}
|
|
|
|
ledsControl OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Electroline manufacturing test leds group"
|
|
::= { prodTest 3 }
|
|
|
|
ledsControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LedsControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides Read/Write access to Leds port."
|
|
::= { ledsControl 1 }
|
|
|
|
ledsControlEntry OBJECT-TYPE
|
|
SYNTAX LedsControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Led Control index and value."
|
|
INDEX { ledId }
|
|
::= { ledsControlTable 1 }
|
|
|
|
LedsControlEntry ::=
|
|
SEQUENCE
|
|
{
|
|
ledId
|
|
INTEGER,
|
|
|
|
ledState
|
|
INTEGER,
|
|
|
|
ledDesc
|
|
OCTET STRING
|
|
}
|
|
|
|
ledId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into the le led Control value table."
|
|
::= { ledsControlEntry 1 }
|
|
|
|
ledState OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control of the LED
|
|
0: Unknown state
|
|
1: OFF
|
|
2: ON
|
|
|
|
Note: Get on this mib always return Unknown state because
|
|
we cannot know internally what is the state of the led.
|
|
Note that inverse polarity is taken into account."
|
|
|
|
::= { ledsControlEntry 2 }
|
|
|
|
ledDesc OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gives the name of the current PortId"
|
|
::= { ledsControlEntry 3 }
|
|
|
|
elineSpectrumAnalyzer OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Test function related to the spectrum analyzer"
|
|
::= { commonPrivate 3 }
|
|
|
|
plantPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Test group to calculate the total power between 2 frequencies."
|
|
::= { elineSpectrumAnalyzer 1 }
|
|
|
|
plantPowerStartFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fisrt frequency of the span to calculate in Hz
|
|
"
|
|
::= { plantPower 1 }
|
|
|
|
plantPowerStopFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last frequency of the span to calculate in Hz
|
|
"
|
|
::= { plantPower 2 }
|
|
|
|
plantPowerNbAverage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of FFT to perform and average the result
|
|
"
|
|
::= { plantPower 3 }
|
|
|
|
plantPowerPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the calculated power in 0.01 dBmV. Important, this function will hang the SNMP agent. Be carrefull!
|
|
Also, the RBW used will be caluclated to get as near as possible to 2048 bins. That we, we achieve the best
|
|
possible result within the span specified. You can look at the planPowerRbw and plantPowerNbBins mibs
|
|
to know the value used.
|
|
|
|
Also, the FFT windows filter use is Hanning. So do not expect to get the best result on analog channels."
|
|
::= { plantPower 4 }
|
|
|
|
planPowerRBW OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the RBW used to make the last calculation"
|
|
::= { plantPower 5 }
|
|
|
|
plantPowerNbBins OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the number of bins used to make the last calculation"
|
|
::= { plantPower 6 }
|
|
|
|
privateStatus OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Status"
|
|
::= { commonPrivate 4 }
|
|
|
|
dieTemperature OBJECT-TYPE
|
|
SYNTAX TenthCelsius
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the die temperature in tenth of Celsius read from the bcm chip internal temperature probe. Note that only the 3383 has this probe."
|
|
::= { privateStatus 1 }
|
|
|
|
END
|