Observium_CE/mibs/ekinops/EKINOPS-Pmvoa-MIB

1922 lines
45 KiB
Plaintext
Raw Blame History

-- *****************************************************************
-- EKINOPS-Pmvoa.TXT: MIB
--
--MIB Part Number:3MI00124AAAA
--MIB Version:02
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-Pmvoa-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulePmvoa MODULE-IDENTITY
LAST-UPDATED "201612210000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.fr"
DESCRIPTION
"Creation."
REVISION "201612210000Z"
DESCRIPTION
"Creation for PMVOA"
::= { ekinops 84 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pmvoaalarms OBJECT IDENTIFIER ::= { modulePmvoa 2 }
pmvoaAlmOther OBJECT IDENTIFIER ::= { pmvoaalarms 1 }
pmvoaAlmOtherNurg OBJECT IDENTIFIER ::= { pmvoaAlmOther 1 }
pmvoaAlmOtherUrg OBJECT IDENTIFIER ::= { pmvoaAlmOther 2 }
pmvoaAlmOtherCrit OBJECT IDENTIFIER ::= { pmvoaAlmOther 3 }
pmvoaAlmClient OBJECT IDENTIFIER ::= { pmvoaalarms 2 }
pmvoaAlmClientNurg OBJECT IDENTIFIER ::= { pmvoaAlmClient 1 }
pmvoaAlmClientUrg OBJECT IDENTIFIER ::= { pmvoaAlmClient 2 }
pmvoaAlmClientCrit OBJECT IDENTIFIER ::= { pmvoaAlmClient 3 }
pmvoaAlmLine OBJECT IDENTIFIER ::= { pmvoaalarms 3 }
pmvoaAlmLineNurg OBJECT IDENTIFIER ::= { pmvoaAlmLine 1 }
pmvoaAlmLineUrg OBJECT IDENTIFIER ::= { pmvoaAlmLine 2 }
pmvoaAlmLineCrit OBJECT IDENTIFIER ::= { pmvoaAlmLine 3 }
pmvoameasures OBJECT IDENTIFIER ::= { modulePmvoa 3 }
pmvoaMesrOther OBJECT IDENTIFIER ::= { pmvoameasures 1 }
pmvoaMesrClient OBJECT IDENTIFIER ::= { pmvoameasures 2 }
pmvoaMesrLine OBJECT IDENTIFIER ::= { pmvoameasures 3 }
pmvoacontrolsWrite OBJECT IDENTIFIER ::= { modulePmvoa 6 }
pmvoaCtrlOther OBJECT IDENTIFIER ::= { pmvoacontrolsWrite 1 }
pmvoaCtrlClient OBJECT IDENTIFIER ::= { pmvoacontrolsWrite 2 }
pmvoaCtrlLine OBJECT IDENTIFIER ::= { pmvoacontrolsWrite 3 }
pmvoari OBJECT IDENTIFIER ::= { modulePmvoa 7 }
pmvoariTable OBJECT IDENTIFIER ::= { pmvoari 1 }
pmvoadownload OBJECT IDENTIFIER ::= { modulePmvoa 8 }
pmvoaDwlOther OBJECT IDENTIFIER ::= { pmvoadownload 1 }
pmvoaDwlClient OBJECT IDENTIFIER ::= { pmvoadownload 2 }
pmvoaDwlLine OBJECT IDENTIFIER ::= { pmvoadownload 3 }
pmvoaConfig OBJECT IDENTIFIER ::= { modulePmvoa 9 }
pmvoatraps OBJECT IDENTIFIER ::= { modulePmvoa 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
PmvoaMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Mode for the SFP VOA"
SYNTAX INTEGER {
attenuationctrl(0),
powerctrl(1)
}
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmvoaRinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pmvoari 2 }
pmvoaRinvHwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HW platform description: This OID contains the
description of the Hardware platform."
::= { pmvoari 3 }
pmvoaRinvModulePlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pmvoari 4 }
pmvoaRinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pmvoari 5 }
pmvoaRinvGwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GW platform description: This OID contains the
description of the Gateware platform."
::= { pmvoari 6 }
--- ***Clients***
---pmvoaRinvSfpTable OBJECT-TYPE
--- SYNTAX SEQUENCE OF PmvoaRinvSfpEntry
--- MAX-ACCESS not-accessible
--- STATUS current
--- DESCRIPTION
--- "List of the SFPs on the selected module"
--- ::= { pmvoariTable 1 }
---pmvoaRinvSfpEntry OBJECT-TYPE
--- SYNTAX PmvoaRinvSfpEntry
--- MAX-ACCESS not-accessible
--- STATUS current
--- DESCRIPTION
--- "Row definition for the SFP table"
--- INDEX { pmvoaRinvSfpIndex }
--- ::= { pmvoaRinvSfpTable 1 }
---PmvoaRinvSfpEntry::=
--- SEQUENCE {
--- pmvoaRinvSfpIndex
--- Integer32,
--- pmvoaRinvsfp
--- DisplayString
--- }
--- pmvoaRinvSfpIndex OBJECT-TYPE
--- SYNTAX Integer32(1..16)
--- MAX-ACCESS read-only
--- STATUS current
--- DESCRIPTION
--- "Index for SFP table"
--- ::= { pmvoaRinvSfpEntry 1 }
--- pmvoaRinvsfp OBJECT-TYPE
--- SYNTAX DisplayString
--- MAX-ACCESS read-only
--- STATUS current
--- DESCRIPTION
--- "Inventory for the SFP: This OID contains the inventory for the SFP"
--- ::= { pmvoaRinvSfpEntry 2 }
--- ***Lines***
pmvoaRinvLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaRinvLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the SFPs on the selected module"
::= { pmvoariTable 2 }
pmvoaRinvLineEntry OBJECT-TYPE
SYNTAX PmvoaRinvLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the SFP table"
INDEX { pmvoaRinvLineIndex }
::= { pmvoaRinvLineTable 1 }
PmvoaRinvLineEntry::=
SEQUENCE {
pmvoaRinvLineIndex
Integer32,
pmvoaRinvxfpLine
DisplayString
}
pmvoaRinvLineIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for SFP table"
::= { pmvoaRinvLineEntry 1 }
pmvoaRinvxfpLine OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the XFP: This OID contains the inventory for the XFP"
::= { pmvoaRinvLineEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pmvoaAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmvoaAlmOtherCrit 0 }
pmvoaAlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help> Status
of the Fuse B <Condtype> DEF_FUSE_B
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmvoaAlmsynthAlm0 16 }
pmvoaAlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help> Status
of the Fuse A <Condtype> DEF_FUSE_A
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmvoaAlmsynthAlm0 15 }
pmvoaAlmModGlobFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the RM <Help> This alarm is
set on detection of a failure originating
from the equipment <Condtype> MOD_GLOB_FAIL
<Probcause> other (1) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmvoaAlmsynthAlm0 9 }
--- *****************************************************
--- LEAF for the synthAlm2 article
--- *****************************************************
pmvoaAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmvoaAlmOtherNurg 2 }
pmvoaAlmCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Not Used :This OID, when set,
indicates that alarm correlation
is not being performed. <Condtype>
CORRELAT_OFF <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmvoaAlmsynthAlm2 4 }
pmvoaAlmConfTableLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Load :This OID
is at 1 during the loading of
configuration tables in the modules
RAM. <Condtype> CONF_TABLE_LOAD
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmvoaAlmsynthAlm2 3 }
pmvoaAlmInvUpload OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Inventory Upload :This OID is
at 1 during the uploading of PM
inventory information. <Condtype>
INV_UPLOAD <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmvoaAlmsynthAlm2 2 }
pmvoaAlmConfTableSave OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Save :This OID
is at 1 during the saving of a
new configuration table in the
module Flash memory. <Condtype>
CONF_TABLE_SAVE <Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmvoaAlmsynthAlm2 1 }
--- *********************************************************
--- TABLE for the pmvoaAlmsynthAlmLine articles
--- *********************************************************
pmvoaAlmsynthAlmLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaAlmsynthAlmLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pmvoaAlmsynthAlmLine Article
"
::= { pmvoaAlmLineCrit 24 }
pmvoaAlmsynthAlmLineEntry OBJECT-TYPE
SYNTAX PmvoaAlmsynthAlmLineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pmvoaAlmsynthAlmLine
table
"
INDEX { pmvoaAlmsynthAlmLineIndex }
::= { pmvoaAlmsynthAlmLineTable 1 }
PmvoaAlmsynthAlmLineEntry ::=
SEQUENCE {
pmvoaAlmsynthAlmLineIndex
INTEGER,
pmvoaAlmLineFailPortn
EkiOnOff,
pmvoaAlmLineOosPortn
EkiOnOff,
pmvoaAlmLineHwFailPortn
EkiOnOff,
pmvoaAlmLineSfpVoaAbsentPortn
EkiOnOff
}
pmvoaAlmsynthAlmLineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pmvoaAlmsynthAlmLine
table
"
::= { pmvoaAlmsynthAlmLineEntry 1 }
pmvoaAlmLineFailPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port Failure :This OID indicates
a failure on the line port <Help>
This alarm indicates a failure
on the line port <Condtype> LINE_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmvoaAlmsynthAlmLineEntry 13 }
pmvoaAlmLineOosPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
VOA Module Out Of Service :This
OID indicates that the SFP is In
Service or Out of Service<Help>
This status indicates if the VOA
SFP is in service <Condtype> LINE_OOS
<Probcause> informationalStatus(1000)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmvoaAlmsynthAlmLineEntry 7 }
pmvoaAlmLineHwFailPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Help> This alarm indicates a failure
on line port, most probably caused
by a HW issue <Condtype> LINE_HW_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmvoaAlmsynthAlmLineEntry 5 }
pmvoaAlmLineSfpVoaAbsentPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
VOA Module Absent :This OID indicates
that the VOA SFP is not present.
<Help> This alarm indicates if
the VOA SFP is absent <Condtype>
LINE_SFP_VOA_ABSENT <Probcause>
inputOutputDeviceError (24) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
<Event> ObjectCDSingleClientInv
"
::= { pmvoaAlmsynthAlmLineEntry 2 }
--- *********************************************************
--- TABLE for the pmvoaAlmlineAlm articles
--- *********************************************************
pmvoaAlmlineAlmTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaAlmlineAlmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pmvoaAlmlineAlm Article
"
::= { pmvoaAlmLineCrit 40 }
pmvoaAlmlineAlmEntry OBJECT-TYPE
SYNTAX PmvoaAlmlineAlmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pmvoaAlmlineAlm
table
"
INDEX { pmvoaAlmlineAlmIndex }
::= { pmvoaAlmlineAlmTable 1 }
PmvoaAlmlineAlmEntry ::=
SEQUENCE {
pmvoaAlmlineAlmIndex
INTEGER,
pmvoaAlmLossInputPowerPortn
EkiOnOff,
pmvoaAlmTempLowAlarmPortn
EkiOnOff,
pmvoaAlmTempHighAlarmPortn
EkiOnOff,
pmvoaAlmLossOutputPowerPortn
EkiOnOff,
pmvoaAlmOutputErrorPortn
EkiOnOff
}
pmvoaAlmlineAlmIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pmvoaAlmlineAlm
table
"
::= { pmvoaAlmlineAlmEntry 1 }
pmvoaAlmLossInputPowerPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Loss Of Input Power :This OID
indicates that the VOA SFP attenuation
has no input power) <Help> Alarm
indicating that the VOA SFP attenuation
has no input power <Condtype> LOSS_INPUT_POWER_1
<Probcause> lossOfSignal(30) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmvoaAlmlineAlmEntry 6 }
pmvoaAlmTempLowAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
VOA Temp Low Alarm :OID indicates
the VOA SFP Temperature is lower
than the threshold value written
in the SFP <Help> Alarm indicating
that the VOA SFP Temperature is
lower than the threshold value
written in the SFP <Condtype>
TEMP_LOW_ALARM_1 <Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmvoaAlmlineAlmEntry 5 }
pmvoaAlmTempHighAlarmPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
VOA Temp High Alarm :This OID
indicates the VOA SFP Temperature
is higher than the threshold value
written in the SFP <Help> Alarm
indicating that the VOA SFP Temperature
is higher than the threshold value
written in the SFP <Condtype> TEMP_HIGH_ALARM_1
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmvoaAlmlineAlmEntry 4 }
pmvoaAlmLossOutputPowerPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Loss Of Output Power :This OID
indicates that the VOA SFP attenuation
is infinite (no output power) <Help>
Alarm indicating that the VOA SFP
attenuation is infinite (no output
power) <Condtype> LOSS_OUTPUT_POWER_1
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmvoaAlmlineAlmEntry 3 }
pmvoaAlmOutputErrorPortn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
VOA Module Output power Failure
:When configured in Constant Output
Power, this OID indicates the required
output power can<61>t be reached
<Help> When configured in Constant
output power, this alarm indicates
the required output power can<61>t
be reached <Condtype> OUTPUT_ERROR_1
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmvoaAlmlineAlmEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the confMgnt1 article
--- *****************************************************
pmvoaCtrlconfMgnt1 OBJECT IDENTIFIER ::= { pmvoaCtrlOther 1 }
pmvoaCtrlConf2Clear1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
OID clears the configuration tables
from configuration2 in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pmvoaCtrlconfMgnt1 14 }
pmvoaCtrlConf2Flash1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
OID saves the current configuration
of the PM as configuration2 in
the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pmvoaCtrlconfMgnt1 10 }
pmvoaCtrlConf2Load1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables Set
Nb 2 :When set this OID enables
loading from flash configuration2
into the PM.
"
::= { pmvoaCtrlconfMgnt1 2 }
pmvoaCtrlConf1Load1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables Set
Nb 1 :When set this OID enables
loading from flash configuration1
into the PM.
"
::= { pmvoaCtrlconfMgnt1 1 }
--- *****************************************************
--- LEAF for the synth4 article
--- *****************************************************
pmvoaCtrlsynth4 OBJECT IDENTIFIER ::= { pmvoaCtrlOther 4 }
pmvoaCtrlCorrelatOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Disable Alarm Correlation :This
OID disables the alarm correlation
in the PM.
"
::= { pmvoaCtrlsynth4 2 }
pmvoaCtrlCorrelatOn OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Enable Alarm Correlation :This
OID enables the alarm correlation
in the PM.
"
::= { pmvoaCtrlsynth4 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pmvoaCtrlswMgnt OBJECT IDENTIFIER ::= { pmvoaCtrlOther 5 }
pmvoaCtrlLoadSwBank2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Software Nb 2 As Active :This
OID, when set, loads the SW from
bank2 into the PM. It must be followed
by a reset. <Help> This controls
selects the second SW bank as the
active bank for the next module
reset
"
::= { pmvoaCtrlswMgnt 6 }
pmvoaCtrlLoadSwBank1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Software Nb 1 As Active :This
OID, when set, loads the SW from
bank1 into the PM. It must be followed
by a reset. <Help> This controls
selects the first SW bank as the
active bank for the next module
reset
"
::= { pmvoaCtrlswMgnt 5 }
pmvoaCtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Warm Reset :This OID, when
set, causes a warm reset of the
PM. This reset is not traffic affecting,
and the configuration of PM remains
unchanged. <Help> This control
initiates a warm reset of the module.
"
::= { pmvoaCtrlswMgnt 3 }
pmvoaCtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Cold Reset :This OID, when
set, causes a cold reset of the
PM. This reset is traffic affecting,
and the configuration of PM is
reloaded on start-up. <Help>
This control initiates a cold
reset of the module.
"
::= { pmvoaCtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the gwMgnt article
--- *****************************************************
pmvoaCtrlgwMgnt OBJECT IDENTIFIER ::= { pmvoaCtrlOther 6 }
pmvoaCtrlLoadGwBank4 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Gateware Nb 4 As Active :This
OID, when set, loads the GW from
bank4 (Flash) into the PM. It is
followed by an automatic gateware
cold reset.
"
::= { pmvoaCtrlgwMgnt 8 }
pmvoaCtrlLoadGwBank3 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Gateware Nb 3 As Active :This
OID, when set, loads the GW from
bank3 (Flash) into the PM. It is
followed by an automatic gateware
cold reset. <Help> This controls
initiates a cold reset of the module
and select the third GW bank as
the active bank
"
::= { pmvoaCtrlgwMgnt 7 }
pmvoaCtrlLoadGwBank2 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Gateware Nb 2 As Active :This
OID, when set, loads the GW from
bank2 (Flash) into the PM. It is
followed by an automatic gateware
cold reset.
"
::= { pmvoaCtrlgwMgnt 6 }
pmvoaCtrlLoadGwBank1 OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Set Gateware Nb 1 As Active :This
OID, when set, loads the GW from
bank1 (Flash) into the PM. It is
followed by an automatic gateware
cold reset. <Help> This controls
initiates a cold reset of the module
and select the first GW bank as
the active bank
"
::= { pmvoaCtrlgwMgnt 5 }
pmvoaCtrlCurrentGwReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Active Gateware Reset :This OID,
when set, resets the active gateware.
It is traffic affecting.
"
::= { pmvoaCtrlgwMgnt 1 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pmvoaCtrlledTest OBJECT IDENTIFIER ::= { pmvoaCtrlOther 72 }
pmvoaCtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pmvoaCtrlledTest 3 }
pmvoaCtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pmvoaCtrlledTest 2 }
pmvoaCtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pmvoaCtrlledTest 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *********************************************************
--- TABLE for the pmvoaMesrlineSfpTemp articles
--- *********************************************************
pmvoaMesrlineSfpTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaMesrlineSfpTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pmvoaMesrlineSfpTemp Article
"
::= { pmvoaMesrLine 16 }
pmvoaMesrlineSfpTempEntry OBJECT-TYPE
SYNTAX PmvoaMesrlineSfpTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pmvoaMesrlineSfpTemp
table
"
INDEX { pmvoaMesrlineSfpTempIndex }
::= { pmvoaMesrlineSfpTempTable 1 }
PmvoaMesrlineSfpTempEntry ::=
SEQUENCE {
pmvoaMesrlineSfpTempIndex
INTEGER,
pmvoaMesrlineSfpTempPortn
INTEGER
}
pmvoaMesrlineSfpTempIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pmvoaMesrlineSfpTemp
table
"
::= { pmvoaMesrlineSfpTempEntry 1 }
pmvoaMesrlineSfpTempPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature :This OID gives the
temperature value of the VOA SFP
(Temperature = AV_S16/256) (Unit
= C) <Help> This measure gives
the temperature value of the VOA
SFP
"
::= { pmvoaMesrlineSfpTempEntry 2 }
--- *********************************************************
--- TABLE for the pmvoaMesrlinePout articles
--- *********************************************************
pmvoaMesrlinePoutTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaMesrlinePoutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pmvoaMesrlinePout Article
"
::= { pmvoaMesrLine 48 }
pmvoaMesrlinePoutEntry OBJECT-TYPE
SYNTAX PmvoaMesrlinePoutEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pmvoaMesrlinePout
table
"
INDEX { pmvoaMesrlinePoutIndex }
::= { pmvoaMesrlinePoutTable 1 }
PmvoaMesrlinePoutEntry ::=
SEQUENCE {
pmvoaMesrlinePoutIndex
INTEGER,
pmvoaMesrlinePoutPortn
INTEGER
}
pmvoaMesrlinePoutIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pmvoaMesrlinePout
table
"
::= { pmvoaMesrlinePoutEntry 1 }
pmvoaMesrlinePoutPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Output Power :This OID gives the
output power value of the VOA SFP
(Power = 10*log(AV_U16)-40) (Unit
= dBm) <Help> This measure gives
the output power value of the VOA
SFP
"
::= { pmvoaMesrlinePoutEntry 2 }
--- *********************************************************
--- TABLE for the pmvoaMesrlineEstPin articles
--- *********************************************************
pmvoaMesrlineEstPinTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaMesrlineEstPinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of pmvoaMesrlineEstPin Article
"
::= { pmvoaMesrLine 64 }
pmvoaMesrlineEstPinEntry OBJECT-TYPE
SYNTAX PmvoaMesrlineEstPinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the pmvoaMesrlineEstPin
table
"
INDEX { pmvoaMesrlineEstPinIndex }
::= { pmvoaMesrlineEstPinTable 1 }
PmvoaMesrlineEstPinEntry ::=
SEQUENCE {
pmvoaMesrlineEstPinIndex
INTEGER,
pmvoaMesrlineEstPinPortn
INTEGER
}
pmvoaMesrlineEstPinIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the pmvoaMesrlineEstPin
table
"
::= { pmvoaMesrlineEstPinEntry 1 }
pmvoaMesrlineEstPinPortn OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Estimated Input Power :This OID
gives the estimated input power
value of the VOA SFP (Power = 10*log(AV_U16)-40)
(Unit = dBm) <Help> This measure
gives the estimated input power
value of the VOA SFP
"
::= { pmvoaMesrlineEstPinEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- DOWNLOAD
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the restartProcess article
--- *****************************************************
pmvoaDwlrestartProcess OBJECT IDENTIFIER ::= { pmvoaDwlOther 0 }
pmvoaDwlColdRestartProcessed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Cold Restart :This OID indicates
that the module last restart was
a Cold RESTART
"
::= { pmvoaDwlrestartProcess 2 }
pmvoaDwlWarmRestartProcessed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warm Restart :This OID indicates
that the module last restart was
a Warm RESTART
"
::= { pmvoaDwlrestartProcess 1 }
--- *****************************************************
--- LEAF for the swBanksUsed article
--- *****************************************************
pmvoaDwlswBanksUsed OBJECT IDENTIFIER ::= { pmvoaDwlOther 1 }
pmvoaDwlSwBank2Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SW bank 2 loaded :This OID indicates
a software is loaded in SW bank
2 <Help> This status indicates
if the SW bank 2 contains SW package
"
::= { pmvoaDwlswBanksUsed 6 }
pmvoaDwlSwBank1Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SW bank 1 loaded :This OID indicates
a software is loaded in SW bank
1 <Help> This status indicates
if the SW bank 1 contains SW package
"
::= { pmvoaDwlswBanksUsed 5 }
pmvoaDwlSwBank2Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SW bank 2 active :This OID indicates
the module is working on SW bank
2 <Help> This status indicates
if the SW bank 2 is active or standby
"
::= { pmvoaDwlswBanksUsed 2 }
pmvoaDwlSwBank1Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
SW bank 1 active :This OID indicates
the module is working on SW bank
1 <Help> This status indicates
if the SW bank 1 is active or standby
"
::= { pmvoaDwlswBanksUsed 1 }
--- *****************************************************
--- LEAF for the gwBanksUsed article
--- *****************************************************
pmvoaDwlgwBanksUsed OBJECT IDENTIFIER ::= { pmvoaDwlOther 2 }
pmvoaDwlGwBank4Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 4 loaded :This OID indicates
a gateware is loaded in GW bank
4
"
::= { pmvoaDwlgwBanksUsed 8 }
pmvoaDwlGwBank3Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 3 loaded :This OID indicates
a gateware is loaded in GW bank
3 <Help> This status indicates
if the GW bank 3 contains GW package
"
::= { pmvoaDwlgwBanksUsed 7 }
pmvoaDwlGwBank2Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 2 loaded :This OID indicates
a gateware is loaded in GW bank
2
"
::= { pmvoaDwlgwBanksUsed 6 }
pmvoaDwlGwBank1Notempty OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 1 loaded :This OID indicates
a gateware is loaded in GW bank
1 <Help> This status indicates
if the GW bank 1 contains GW package
"
::= { pmvoaDwlgwBanksUsed 5 }
pmvoaDwlGwBank4Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 4 active :This OID indicates
the module is working on GW bank
4
"
::= { pmvoaDwlgwBanksUsed 4 }
pmvoaDwlGwBank3Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 3 active :This OID indicates
the module is working on GW bank
3 <Help> This status indicates
if the GW bank 3 is active or standby
"
::= { pmvoaDwlgwBanksUsed 3 }
pmvoaDwlGwBank2Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 2 active :This OID indicates
the module is working on GW bank
2
"
::= { pmvoaDwlgwBanksUsed 2 }
pmvoaDwlGwBank1Used OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
GW bank 1 active :This OID indicates
the module is working on GW bank
1 <Help> This status indicates
if the GW bank 1 is active or standby
"
::= { pmvoaDwlgwBanksUsed 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group startup
--- *****************************************************
pmvoaCfgStartup OBJECT IDENTIFIER ::= { pmvoaConfig 1 }
--- *****************************************************
--- LEAF for the table 2190
--- *****************************************************
pmvoaCfgLinexr1StartupTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaCfgLinexr1StartupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmvoaCfgStartup 1 }
pmvoaCfgLinexr1StartupEntry OBJECT-TYPE
SYNTAX PmvoaCfgLinexr1StartupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the startup
table
"
INDEX { pmvoaCfgLinexr1StartupIndex }
::= { pmvoaCfgLinexr1StartupTable 1 }
PmvoaCfgLinexr1StartupEntry ::=
SEQUENCE {
pmvoaCfgLinexr1StartupIndex
INTEGER,
pmvoaCfgSfpModePortn
Unsigned32,
pmvoaCfgAttenuationCtrlPortn
Unsigned32,
pmvoaCfgPowerCtrlPortn
Unsigned32,
pmvoaCfgLosInputThresholdPortn
Unsigned32,
pmvoaCfgInsertionLossValuePortn
Unsigned32
}
pmvoaCfgLinexr1StartupIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the linexr1Startup
table
"
::= { pmvoaCfgLinexr1StartupEntry 1 }
pmvoaCfgSfpModePortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default mode on the SFP :This
register configures the default
initialisation settings on the
SFP
"
::= { pmvoaCfgLinexr1StartupEntry 3 }
pmvoaCfgAttenuationCtrlPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default attenuation setting on
the SFP :This register configures
the default initialisation settings
of the attenuation
"
::= { pmvoaCfgLinexr1StartupEntry 4 }
pmvoaCfgPowerCtrlPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default power setting on the SFP
:This register configures the
default initialisation settings
of the power
"
::= { pmvoaCfgLinexr1StartupEntry 5 }
pmvoaCfgLosInputThresholdPortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default threshold setting on the
SFP :This register configures
the default initialisation settings
of the input threshold
"
::= { pmvoaCfgLinexr1StartupEntry 6 }
pmvoaCfgInsertionLossValuePortn OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Insertion Loss setting
on the SFP :This register configures
the default initialisation settings
of the insertion loss value
"
::= { pmvoaCfgLinexr1StartupEntry 7 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pmvoaCfgLabels OBJECT IDENTIFIER ::= { pmvoaConfig 2 }
--- *****************************************************
--- LEAF for the table 0003
--- *****************************************************
pmvoaCfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmvoaCfgLabels 1 }
pmvoaCfgLabelclientEntry OBJECT-TYPE
SYNTAX PmvoaCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmvoaCfgLabelclientIndex }
::= { pmvoaCfgLabelclientTable 1 }
PmvoaCfgLabelclientEntry ::=
SEQUENCE {
pmvoaCfgLabelclientIndex
INTEGER,
pmvoaCfgLabelclientPortn
DisplayString
}
pmvoaCfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pmvoaCfgLabelclientEntry 1 }
pmvoaCfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pmvoaCfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table 0004
--- *****************************************************
pmvoaCfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmvoaCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmvoaCfgLabels 2 }
pmvoaCfgLabellineEntry OBJECT-TYPE
SYNTAX PmvoaCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmvoaCfgLabellineIndex }
::= { pmvoaCfgLabellineTable 1 }
PmvoaCfgLabellineEntry ::=
SEQUENCE {
pmvoaCfgLabellineIndex
INTEGER,
pmvoaCfgLabellinePortn
DisplayString
}
pmvoaCfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pmvoaCfgLabellineEntry 1 }
pmvoaCfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pmvoaCfgLabellineEntry 3 }
pmvoaCfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pmvoaConfig 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pmvoatrapPortNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last port which generates a trap"
::= { pmvoatraps 2 }
pmvoatrapLineNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last Line which generates a trap"
::= { pmvoatraps 3 }
pmvoatrapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pmvoatraps 4 }
--- *****************************************************
--- LINE TRAPS
--- *****************************************************
pmvoaLineTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmvoaAlmLineFailPortn , pmvoaAlmLineHwFailPortn , pmvoatrapLineNumber, pmvoatrapBoardNumber}
STATUS current
--&FILTNAME "PMVOA Line Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmvoaAlmLineFailPortn "on", pmvoaAlmLineHwFailPortn "*", pmvoatrapLineNumber "$3", pmvoatrapBoardNumber "$4"}
--&MESG "Line Port $3 Down on PMVOA in Slot $4 ($A)"
--&FILTNAME "PMVOA Line HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmvoaAlmLineFailPortn "*", pmvoaAlmLineHwFailPortn "on", pmvoatrapLineNumber "$3", pmvoatrapBoardNumber "$4"}
--&MESG "Line Port $3 Down on PMVOA in Slot $4 ($A)"
DESCRIPTION "Critical Line default is activated"
::= { pmvoatraps 34 }
pmvoaLineTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmvoaAlmLineFailPortn , pmvoaAlmLineHwFailPortn , pmvoatrapLineNumber, pmvoatrapBoardNumber}
STATUS current
--&FILTNAME "PMVOA Line Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS { "PMVOA Line Fail ON" }
--&MATCH { pmvoaAlmLineFailPortn "on", pmvoaAlmLineHwFailPortn "*", pmvoatrapLineNumber "$3", pmvoatrapBoardNumber "$4"}
--&MESG "Line Port $3 Up on PMVOA in Slot $4 ($A)"
--&FILTNAME "PMVOA Line HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmvoaAlmLineFailPortn "*", pmvoaAlmLineHwFailPortn "on", pmvoatrapLineNumber "$3", pmvoatrapBoardNumber "$4"}
--&MESG "Line Port $3 Up on PMVOA in Slot $4 ($A)"
DESCRIPTION "Critical Line default disappeared"
::= { pmvoatraps 35 }
--- *****************************************************
--- CLIENT TRAPS
--- *****************************************************
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pmvoaPowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmvoaAlmDefFuseB, pmvoaAlmDefFuseA , pmvoatrapBoardNumber}
STATUS current
--&FILTNAME "PMVOA Fuse A Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmvoaAlmDefFuseB "*", pmvoaAlmDefFuseA "on", pmvoatrapBoardNumber "$3"}
--&MESG "Power Input A Fail on PMVOA in Slot $3 ($A)"
--&FILTNAME "PMVOA Fuse B Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmvoaAlmDefFuseB "on", pmvoaAlmDefFuseA "*", pmvoatrapBoardNumber "$3"}
--&MESG "Power Input B Fail on PMVOA in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default is activated"
::= { pmvoatraps 50 }
pmvoaPowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmvoaAlmDefFuseB, pmvoaAlmDefFuseA , pmvoatrapBoardNumber}
STATUS current
--&FILTNAME "PMVOA Fuse A&B Fail OFF"
--&ACTIONS { log, normal}
--&CLEARS { "PMVOA Fuse A Fail ON", "PMVOA Fuse B Fail ON" }
--&MATCH { pmvoaAlmDefFuseB "on", pmvoaAlmDefFuseA "on", pmvoatrapBoardNumber "$3"}
--&MESG "Power Inputs A and B Present on PMVOA in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default disappeared"
::= { pmvoatraps 51 }
END