2589 lines
70 KiB
Plaintext
2589 lines
70 KiB
Plaintext
-- *****************************************************************
|
||
-- EKINOPS-Pmpump3.TXT: MIB
|
||
--
|
||
--MIB Part Number:3MI00207ABAD
|
||
--MIB Version:01
|
||
--
|
||
-- Copyright (c) 2016 by Ekinops
|
||
-- All rights reserved.
|
||
--
|
||
-- *****************************************************************
|
||
|
||
EKINOPS-PmPump3-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
ekinops,
|
||
EkiState,
|
||
EkiOnOff,
|
||
EkiMode,
|
||
EkiProtocol,
|
||
EkiApiState,
|
||
EkiSynchroMode,
|
||
EkiMeasureType
|
||
FROM EKINOPS-MIB
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Unsigned32,
|
||
Integer32,
|
||
Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION,
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
modulepmpump3 MODULE-IDENTITY
|
||
LAST-UPDATED "201605230000Z"
|
||
ORGANIZATION "Ekinops"
|
||
CONTACT-INFO
|
||
"Ekinops
|
||
|
||
3, rue Blaise Pascal
|
||
F-22300 Lannion / FRANCE
|
||
|
||
Tel : +33 (0)2 96 05 00 30
|
||
Fax : +33 (0)2 96 48 62 39
|
||
|
||
E-mail: support@ekinops.net"
|
||
DESCRIPTION
|
||
"Creation"
|
||
|
||
REVISION "201009010000Z"
|
||
DESCRIPTION
|
||
"Creation"
|
||
REVISION "201012150000Z"
|
||
DESCRIPTION
|
||
"Add inventory of the lasers"
|
||
REVISION "201109200000Z"
|
||
DESCRIPTION
|
||
"OOS insertion"
|
||
REVISION "201207040000Z"
|
||
DESCRIPTION
|
||
"Minor cosmetic updates"
|
||
REVISION "201403260000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS completion"
|
||
REVISION "201411250000Z"
|
||
DESCRIPTION
|
||
"Labels cosmetic updates"
|
||
REVISION "201605230000Z"
|
||
DESCRIPTION
|
||
"New AlarmType – synthesisAlarm (12)"
|
||
::= { ekinops 49 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF LEVEL 2
|
||
--- *****************************************************
|
||
|
||
|
||
pmpump3alarms OBJECT IDENTIFIER ::= { modulepmpump3 2 }
|
||
pmpump3AlmOther OBJECT IDENTIFIER ::= { pmpump3alarms 1 }
|
||
pmpump3AlmOtherNurg OBJECT IDENTIFIER ::= { pmpump3AlmOther 1 }
|
||
pmpump3AlmOtherUrg OBJECT IDENTIFIER ::= { pmpump3AlmOther 2 }
|
||
pmpump3AlmOtherCrit OBJECT IDENTIFIER ::= { pmpump3AlmOther 3 }
|
||
|
||
pmpump3AlmClient OBJECT IDENTIFIER ::= { pmpump3alarms 2 }
|
||
pmpump3AlmClientNurg OBJECT IDENTIFIER ::= { pmpump3AlmClient 1 }
|
||
pmpump3AlmClientUrg OBJECT IDENTIFIER ::= { pmpump3AlmClient 2 }
|
||
pmpump3AlmClientCrit OBJECT IDENTIFIER ::= { pmpump3AlmClient 3 }
|
||
|
||
pmpump3AlmLine OBJECT IDENTIFIER ::= { pmpump3alarms 3 }
|
||
pmpump3AlmLineNurg OBJECT IDENTIFIER ::= { pmpump3AlmLine 1 }
|
||
pmpump3AlmLineUrg OBJECT IDENTIFIER ::= { pmpump3AlmLine 2 }
|
||
pmpump3AlmLineCrit OBJECT IDENTIFIER ::= { pmpump3AlmLine 3 }
|
||
|
||
|
||
pmpump3measures OBJECT IDENTIFIER ::= { modulepmpump3 3 }
|
||
pmpump3MesrOther OBJECT IDENTIFIER ::= { pmpump3measures 1 }
|
||
pmpump3MesrClient OBJECT IDENTIFIER ::= { pmpump3measures 2 }
|
||
pmpump3MesrLine OBJECT IDENTIFIER ::= { pmpump3measures 3 }
|
||
|
||
|
||
pmpump3controlsWrite OBJECT IDENTIFIER ::= { modulepmpump3 6 }
|
||
pmpump3CtrlOther OBJECT IDENTIFIER ::= { pmpump3controlsWrite 1 }
|
||
pmpump3CtrlClient OBJECT IDENTIFIER ::= { pmpump3controlsWrite 2 }
|
||
pmpump3CtrlLine OBJECT IDENTIFIER ::= { pmpump3controlsWrite 3 }
|
||
|
||
pmpump3ri OBJECT IDENTIFIER ::= { modulepmpump3 7 }
|
||
pmpump3riTable OBJECT IDENTIFIER ::= { pmpump3ri 1 }
|
||
|
||
pmpump3Config OBJECT IDENTIFIER ::= { modulepmpump3 9 }
|
||
|
||
pmpump3traps OBJECT IDENTIFIER ::= { modulepmpump3 10 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- TEXTUAL-CONVENTION
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- REMOTE INVENTORY
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
pmpump3RinvReloadInventory OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reload the inventory: This OID triggers an
|
||
inventory reload."
|
||
::= { pmpump3ri 2 }
|
||
|
||
pmpump3RinvHwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"HW platform description: This OID contains the
|
||
description of the Hardware platform."
|
||
::= { pmpump3ri 3 }
|
||
|
||
pmpump3RinvModulePlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Module platform description: This OID contains the
|
||
description of the Module."
|
||
::= { pmpump3ri 4 }
|
||
|
||
pmpump3RinvSwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SW platform description: This OID contains the
|
||
description of the Software platform."
|
||
::= { pmpump3ri 5 }
|
||
|
||
|
||
|
||
|
||
pmpump3RinvLaser1Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmpump3RinvLaser1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the lasers on the selected module"
|
||
::= { pmpump3riTable 1 }
|
||
|
||
pmpump3RinvLaser1Entry OBJECT-TYPE
|
||
SYNTAX Pmpump3RinvLaser1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the laser table"
|
||
INDEX { pmpump3RinvLaser1Index }
|
||
::= { pmpump3RinvLaser1Table 1 }
|
||
|
||
|
||
Pmpump3RinvLaser1Entry::=
|
||
SEQUENCE {
|
||
pmpump3RinvLaser1Index
|
||
Integer32,
|
||
pmpump3RinvLaser1
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmpump3RinvLaser1Index OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for laser table"
|
||
::= { pmpump3RinvLaser1Entry 1 }
|
||
|
||
|
||
pmpump3RinvLaser1 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the laser: This OID contains the inventory for the laser"
|
||
::= { pmpump3RinvLaser1Entry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
pmpump3RinvLaser2Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmpump3RinvLaser2Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the lasers on the selected module"
|
||
::= { pmpump3riTable 2 }
|
||
|
||
pmpump3RinvLaser2Entry OBJECT-TYPE
|
||
SYNTAX Pmpump3RinvLaser2Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the laser table"
|
||
INDEX { pmpump3RinvLaser2Index }
|
||
::= { pmpump3RinvLaser2Table 1 }
|
||
|
||
|
||
Pmpump3RinvLaser2Entry::=
|
||
SEQUENCE {
|
||
pmpump3RinvLaser2Index
|
||
Integer32,
|
||
pmpump3RinvLaser2
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmpump3RinvLaser2Index OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for laser table"
|
||
::= { pmpump3RinvLaser2Entry 1 }
|
||
|
||
|
||
pmpump3RinvLaser2 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the laser: This OID contains the inventory for the laser"
|
||
::= { pmpump3RinvLaser2Entry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- ALARMS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm0 article
|
||
--- *****************************************************
|
||
pmpump3AlmsynthAlm0 OBJECT IDENTIFIER ::= { pmpump3AlmOtherCrit 0 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmDefFuseB OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse B Fail :This OID indicates
|
||
that the fuse of the power input
|
||
B is in fail condition <Help>
|
||
Status of the Fuse B <Condtype>
|
||
DEF_FUSE_B <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlm0 16 }
|
||
|
||
|
||
|
||
pmpump3AlmDefFuseA OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse A Fail :This OID indicates
|
||
that the fuse of the power input
|
||
A is in fail condition <Help>
|
||
Status of the Fuse A <Condtype>
|
||
DEF_FUSE_A <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlm0 15 }
|
||
|
||
|
||
|
||
pmpump3AlmModGlobFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Failure :This OID is set
|
||
on detection of a failure originating
|
||
from the PM <Condtype> MOD_GLOB_FAIL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlm0 9 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm2 article
|
||
--- *****************************************************
|
||
pmpump3AlmsynthAlm2 OBJECT IDENTIFIER ::= { pmpump3AlmOtherNurg 2 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmConfTableLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Load :This OID
|
||
is at 1 during the loading of
|
||
configuration tables in the modules
|
||
RAM. <Condtype> CONF_TABLE_LOAD
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlm2 3 }
|
||
|
||
|
||
|
||
pmpump3AlmInvUpload OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Inventory Upload :This OID is
|
||
at 1 during the uploading of PM
|
||
inventory information. <Condtype>
|
||
INV_UPLOAD <Probcause> other (1)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmpump3AlmsynthAlm2 2 }
|
||
|
||
|
||
|
||
pmpump3AlmConfTableSave OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Save :This OID
|
||
is at 1 during the saving of a
|
||
new configuration table in the
|
||
module Flash memory. <Condtype>
|
||
CONF_TABLE_SAVE <Probcause> other
|
||
(1) <Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmpump3AlmsynthAlm2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlmLaser1 article
|
||
--- *****************************************************
|
||
pmpump3AlmsynthAlmLaser1 OBJECT IDENTIFIER ::= { pmpump3AlmClientCrit 8 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmLaser1Fail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Failure :This
|
||
OID indicates a failure on the
|
||
pump <Condtype> LASER1_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser1 12 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1Alm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Booster / IL1 Pump DDM
|
||
:This OID indicates an alarm is
|
||
present coming out of the IL1 pump
|
||
DDM <Condtype> LASER1_ALM <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser1 10 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1Warning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Booster / IL1 Pump
|
||
DDM :This OID indicates a warning
|
||
is present coming out of IL1 pump
|
||
DDM <Condtype> LASER1_WARNING <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser1 9 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1Oos OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump In Service
|
||
:This OID indicates that the IL1
|
||
pump is In Service (1) of Out or
|
||
Service (2) <Help> This status
|
||
indicates if the IL1 pump is in
|
||
service <Condtype> LASER1_OOS <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser1 6 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1TxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Output Shutdown
|
||
:This OID indicates the IL1 pump
|
||
optical output power is on. <Help>
|
||
This status indicates if the IL1
|
||
laser pump is ON or OFF <Condtype>
|
||
LASER1_TX_OFF <Probcause> other
|
||
(1) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser1 5 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1HwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump HW Failure
|
||
:This OID indicates a failure
|
||
on IL1 pump, most probably caused
|
||
by a HW issue <Condtype> LASER1_HW_FAIL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser1 4 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1InitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Not Ready :This
|
||
OID indicates that the IL1 pump
|
||
is not operational. <Condtype>
|
||
LASER1_INIT_NOT_COMPL <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser1 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlmLaser2 article
|
||
--- *****************************************************
|
||
pmpump3AlmsynthAlmLaser2 OBJECT IDENTIFIER ::= { pmpump3AlmClientCrit 9 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmLaser2Fail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump Failure :This
|
||
OID indicates a failure on the
|
||
pump <Condtype> LASER2_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser2 12 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2Alm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Pre-Amp / IL2 Pump DDM
|
||
:This OID indicates an alarm is
|
||
present coming out of IL2 pump
|
||
DDM <Condtype> LASER2_ALM <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser2 10 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2Warning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Pre-Amp / IL2 Pump
|
||
DDM :This OID indicates a warning
|
||
is present coming out of the IL2
|
||
pump DDM <Condtype> LASER2_WARNING
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser2 9 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2Oos OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump In Service
|
||
:This OID indicates that the IL2
|
||
pump is In Service (1) of Out or
|
||
Service (2) <Help> This status
|
||
indicates if the IL2 pump is in
|
||
service <Condtype> LASER2_OOS <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser2 6 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2TxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump Output Shutdown
|
||
:This OID indicates the IL2 pump
|
||
optical output power is on. <Help>
|
||
This status indicates if the IL2
|
||
laser pump is ON or OFF <Condtype>
|
||
LASER2_TX_OFF <Probcause> other
|
||
(1) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser2 5 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2HwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump HW Failure
|
||
:This OID indicates a failure
|
||
on IL2 pump, most probably caused
|
||
by a HW issue <Condtype> LASER2_HW_FAIL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser2 4 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2InitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump Not Ready :This
|
||
OID indicates that the IL2 pump
|
||
is not operational. <Condtype>
|
||
LASER2_INIT_NOT_COMPL <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmsynthAlmLaser2 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1Alarms1 article
|
||
--- *****************************************************
|
||
pmpump3Almlaser1Alarms1 OBJECT IDENTIFIER ::= { pmpump3AlmClientUrg 16 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmLaser1BiasHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Bias High Alarm
|
||
:This OID indicates that the Bias
|
||
is higher than the alarm threshold
|
||
of the IL1 pump. <Help> This
|
||
alarm indicates if the IL2 bias
|
||
is too high <Condtype> LASER1_BIAS_HIGH_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms1 8 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1BiasLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Bias Low Alarm :This
|
||
OID indicates that the Bias is
|
||
lower than the alarm threshold
|
||
of the IL1 pump. <Help> This
|
||
alarm indicates if the IL2 bias
|
||
is too low <Condtype> LASER1_BIAS_LOW_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms1 7 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1OutputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pwr High Alarm :This
|
||
OID indicates that the Transmit
|
||
Power is higher than the alarm
|
||
threshold of the IL1 pump. <Help>
|
||
This alarm indicates if the IL1
|
||
power is too high <Condtype> LASER1_OUTPUT_PWR_HIGH_ALARM
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms1 6 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1OutputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pwr Low Alarm :This
|
||
OID indicates that the Transmit
|
||
Power is lower than the alarm threshold
|
||
of the IL1 pump. <Help> This
|
||
alarm indicates if the IL1 power
|
||
is too low <Condtype> LASER1_OUTPUT_PWR_LOW_ALARM
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms1 5 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1VthHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Vth High Alarm :This
|
||
OID indicates that the thermistor
|
||
voltage is higher than the alarm
|
||
threshold of the IL1 pump. <Help>
|
||
This alarm indicates if the IL1
|
||
power is too high <Condtype> LASER1_VTH_HIGH_ALARM
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms1 4 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1VthLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Vth Low Alarm :This
|
||
OID indicates that the thermistor
|
||
voltage is lower than the alarm
|
||
threshold of the IL1 pump. <Help>
|
||
This alarm indicates if the IL1
|
||
power is too low <Condtype> LASER1_VTH_LOW_ALARM
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms1 3 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1TempHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Temp High Alarm
|
||
:This OID indicates that the pump
|
||
temperature is higher than the
|
||
alarm threshold of the IL1 pump.
|
||
<Help> This alarm indicates if
|
||
the IL1 pump temperature is too
|
||
high <Condtype> LASER1_TEMP_HIGH_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms1 2 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1TempLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Temp Low Alarm :This
|
||
OID indicates that the pump temperature
|
||
is lower than the alarm threshold
|
||
of the IL1 pump. <Help> This
|
||
alarm indicates if the IL1 pump
|
||
temperature is too low <Condtype>
|
||
LASER1_TEMP_LOW_ALARM <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1Warnings article
|
||
--- *****************************************************
|
||
pmpump3Almlaser1Warnings OBJECT IDENTIFIER ::= { pmpump3AlmClientNurg 17 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmLaser1BiasHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Bias High Warning
|
||
:This OID indicates that the Bias
|
||
is higher than the warning threshold
|
||
of the IL1 pump. <Help> This
|
||
warning indicates if the IL1 bias
|
||
is too high <Condtype> LASER1_BIAS_HIGH_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Warnings 8 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1BiasLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Bias Low Warning
|
||
:This OID indicates that the Bias
|
||
is lower than the warning threshold
|
||
of the IL1 pump. <Help> This
|
||
warning indicates if the IL1 bias
|
||
is too low <Condtype> LASER1_BIAS_LOW_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Warnings 7 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1OutputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pwr High Warning
|
||
:This OID indicates that the Transmit
|
||
Power is higher than the warning
|
||
threshold of the IL1 pump. <Help>
|
||
This warning indicates if the
|
||
IL1 power is too high <Condtype>
|
||
LASER1_OUTPUT_PWR_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Warnings 6 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1OutputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pwr Low Warning
|
||
:This OID indicates that the Transmit
|
||
Power is lower than the warning
|
||
threshold of the IL1 pump. <Help>
|
||
This warning indicates if the
|
||
IL1 power is too low <Condtype>
|
||
LASER1_OUTPUT_PWR_LOW_WARNING <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Warnings 5 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1VthHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Vth High Warning
|
||
:This OID indicates that the thermistor
|
||
voltage is higher than the warning
|
||
threshold of the IL1 pump. <Help>
|
||
This warning indicates if the
|
||
IL1 power is too high <Condtype>
|
||
LASER1_VTH_HIGH_WARNING <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Warnings 4 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1VthLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Vth Low Warning
|
||
:This OID indicates that the thermistor
|
||
voltage is lower than the warning
|
||
threshold of the IL1 pump. <Help>
|
||
This warning indicates if the
|
||
IL1 power is too low <Condtype>
|
||
LASER1_VTH_LOW_WARNING <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Warnings 3 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1TempHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Temp High Warning
|
||
:This OID indicates that the pump
|
||
temperature is higher than the
|
||
warning threshold of the IL1 pump.
|
||
<Help> This warning indicates
|
||
if the IL1 pump temperature is
|
||
too high <Condtype> LASER1_TEMP_HIGH_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Warnings 2 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1TempLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Temp Low Warning
|
||
:This OID indicates that the pump
|
||
temperature is lower than the
|
||
warning threshold of the IL1 pump.
|
||
<Help> This warning indicates
|
||
if the IL1 pump temperature is
|
||
too low <Condtype> LASER1_TEMP_LOW_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Warnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1Alarms2 article
|
||
--- *****************************************************
|
||
pmpump3Almlaser1Alarms2 OBJECT IDENTIFIER ::= { pmpump3AlmClientCrit 19 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmLaser1ExtLsd OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Laser Shutdown :This
|
||
OID indicates that the laser of
|
||
the pump is shut down <Help>
|
||
This status indicates that the
|
||
laser of the pump is shut down
|
||
<Condtype> LASER1_EXT_LSD <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms2 6 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1OaDisconnectedLsd OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Link Disconnected
|
||
:This OID indicates that the link
|
||
betwenn the amplifier and the pump
|
||
is open <Help> This alarm indicates
|
||
that the OA or the fiber is not
|
||
present <Condtype> LASER1_OA_DISCONNECTED_LSD
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms2 5 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1AlmTecDev OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 TEC Deviation :This
|
||
OID indicates that the loop control
|
||
of the TEC is in fail condition
|
||
<Help> This alarm indicates if
|
||
the loop control of the TEC is
|
||
in fail condition <Condtype> LASER1_ALM_TEC_DEV
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> physicalViolation (9)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms2 4 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1AlmTecPower OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 TEC Pw :This OID
|
||
indicates that the TEC power supply
|
||
is in fail condition . <Help>
|
||
This alarm indicates if the TEC
|
||
power is in fail condition <Condtype>
|
||
LASER1_ALM_TEC_POWER <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms2 3 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1AlmTemp OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Temperature Alarm
|
||
:This OID indicates that the temperature
|
||
of the current driver has reached
|
||
the internal limitation. <Help>
|
||
This alarm indicates if the temperature
|
||
has reached its limitation <Condtype>
|
||
LASER1_ALM_TEMP <Probcause> pumpFailure
|
||
(39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms2 2 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser1AlmCurrent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Current Alarm :This
|
||
OID indicates that maximum current
|
||
has reached the internal limitation
|
||
<Help> This alarm indicates if
|
||
the current has reached its limitation
|
||
<Condtype> LASER1_ALM_CURRENT
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser1Alarms2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2Alarms1 article
|
||
--- *****************************************************
|
||
pmpump3Almlaser2Alarms1 OBJECT IDENTIFIER ::= { pmpump3AlmLineUrg 24 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmLaser2BiasHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Bias High Alarm
|
||
:This OID indicates that the Bias
|
||
is higher than the alarm threshold
|
||
of the IL1 Optical Module <Help>
|
||
This alarm indicates if the IL2
|
||
bias is too high <Condtype> LASER2_BIAS_HIGH_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms1 8 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2BiasLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Bias Low Alarm :This
|
||
OID indicates that the Bias is
|
||
lower than the alarm threshold
|
||
of the IL1 Optical Module <Help>
|
||
This alarm indicates if the IL2
|
||
bias is too low <Condtype> LASER2_BIAS_LOW_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms1 7 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2OutputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pwr High Alarm :This
|
||
OID indicates that the Transmit
|
||
Power is higher than the alarm
|
||
threshold of the IL1 Optical Module
|
||
<Help> This alarm indicates if
|
||
the IL2 power is too high <Condtype>
|
||
LASER2_OUTPUT_PWR_HIGH_ALARM <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms1 6 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2OutputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pwr Low Alarm :This
|
||
OID indicates that the Transmit
|
||
Power is lower than the alarm threshold
|
||
of the IL1 Optical Module <Help>
|
||
This alarm indicates if the IL2
|
||
power is too low <Condtype> LASER2_OUTPUT_PWR_LOW_ALARM
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms1 5 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2VthHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Vth High Alarm :This
|
||
OID indicates that the Receive
|
||
Power is higher than the alarm
|
||
threshold of the IL2 Optical Module
|
||
<Help> This alarm indicates if
|
||
the IL2 power is too high <Condtype>
|
||
LASER2_VTH_HIGH_ALARM <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms1 4 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2VthLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Vth Low Alarm :This
|
||
OID indicates that the Receive
|
||
Power is lower than the alarm
|
||
threshold of the IL2 Optical Module
|
||
<Help> This alarm indicates if
|
||
the IL2 power is too low <Condtype>
|
||
LASER2_VTH_LOW_ALARM <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms1 3 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2TempHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Temp High Alarm
|
||
:This OID indicates that the Gain
|
||
is higher than the alarm threshold
|
||
of the IL1 Module <Help> This
|
||
alarm indicates if the IL2 pump
|
||
temperature is too high <Condtype>
|
||
LASER2_TEMP_HIGH_ALARM <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms1 2 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2TempLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Temp Low Alarm :This
|
||
OID indicates that the Gain is
|
||
lower than the alarm threshold
|
||
of the IL1 Module <Help> This
|
||
alarm indicates if the IL2 pump
|
||
temperature is too low <Condtype>
|
||
LASER2_TEMP_LOW_ALARM <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2Warnings article
|
||
--- *****************************************************
|
||
pmpump3Almlaser2Warnings OBJECT IDENTIFIER ::= { pmpump3AlmLineNurg 25 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmLaser2BiasHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Bias High Warning
|
||
:This OID indicates that the Bias
|
||
is higher than the Warning threshold
|
||
of the IL1 Optical Module <Help>
|
||
This warning indicates if the
|
||
IL2 bias is too high <Condtype>
|
||
LASER2_BIAS_HIGH_WARNING <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Warnings 8 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2BiasLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Bias Low Warning
|
||
:This OID indicates that the Bias
|
||
is lower than the Warning threshold
|
||
of the IL1 Optical Module <Help>
|
||
This warning indicates if the
|
||
IL2 bias is too low <Condtype>
|
||
LASER2_BIAS_LOW_WARNING <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Warnings 7 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2OutputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pwr High Warning
|
||
:This OID indicates that the Transmit
|
||
Power is higher than the Warning
|
||
threshold of the IL1 Optical Module
|
||
<Help> This warning indicates
|
||
if the IL2 power is too high <Condtype>
|
||
LASER2_OUTPUT_PWR_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Warnings 6 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2OutputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pwr Low Warning
|
||
:This OID indicates that the Transmit
|
||
Power is lower than the Warning
|
||
threshold of the IL1 Optical Module
|
||
<Help> This warning indicates
|
||
if the IL2 power is too low <Condtype>
|
||
LASER2_OUTPUT_PWR_LOW_WARNING <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Warnings 5 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2VthHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Vth High Warning
|
||
:This OID indicates that the Receive
|
||
Power is higher than the Warning
|
||
threshold of the IL2 Optical Module
|
||
<Help> This warning indicates
|
||
if the IL2 power is too high <Condtype>
|
||
LASER2_VTH_HIGH_WARNING <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Warnings 4 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2VthLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Vth Low Warning
|
||
:This OID indicates that the Receive
|
||
Power is lower than the Warning
|
||
threshold of the IL2 Optical Module
|
||
<Help> This warning indicates
|
||
if the IL2 power is too low <Condtype>
|
||
LASER2_VTH_LOW_WARNING <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Warnings 3 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2TempHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Temp High Warning
|
||
:This OID indicates that the Gain
|
||
is higher than the Warning threshold
|
||
of the IL1 Module <Help> This
|
||
warning indicates if the IL2 pump
|
||
temperature is too high <Condtype>
|
||
LASER2_TEMP_HIGH_WARNING <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Warnings 2 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2TempLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Temp Low Warning
|
||
:This OID indicates that the Gain
|
||
is lower than the Warning threshold
|
||
of the IL1 Module <Help> This
|
||
warning indicates if the IL2 pump
|
||
temperature is too low <Condtype>
|
||
LASER2_TEMP_LOW_WARNING <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Warnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2Alarms2 article
|
||
--- *****************************************************
|
||
pmpump3Almlaser2Alarms2 OBJECT IDENTIFIER ::= { pmpump3AlmLineCrit 27 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmLaser2ExtLsd OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Laser Shutdown :This
|
||
OID indicates that the laser of
|
||
the pump is shut down <Help>
|
||
This status indicates that the
|
||
laser of the pump is shut down
|
||
<Condtype> LASER2_EXT_LSD <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms2 6 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2OaDisconnectedLsd OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump Link Disconnected
|
||
:This OID indicates that the link
|
||
betwenn the amplifier and the pump
|
||
is open <Help> This alarm indicates
|
||
that the OA or the fiber is not
|
||
present <Condtype> LASER2_OA_DISCONNECTED_LSD
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms2 5 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2AlmTecDev OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 TEC Deviation :This
|
||
OID indicates that the loop control
|
||
of the TEC is in fail condition
|
||
<Help> This alarm indicates if
|
||
the loop control of the TEC is
|
||
in fail condition <Condtype> LASER2_ALM_TEC_DEV
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> physicalViolation (9)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms2 4 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2AlmTecPower OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 TEC Pw :This OID
|
||
indicates that the TEC power supply
|
||
is in fail condition . <Help>
|
||
This alarm indicates if the TEC
|
||
power is in fail condition <Condtype>
|
||
LASER2_ALM_TEC_POWER <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms2 3 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2AlmTemp OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Temperature Alarm
|
||
:This OID indicates that the temperature
|
||
of the current driver has reached
|
||
the internal limitation. <Help>
|
||
This alarm indicates if the temperature
|
||
has reached its limitation <Condtype>
|
||
LASER2_ALM_TEMP <Probcause> pumpFailure
|
||
(39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms2 2 }
|
||
|
||
|
||
|
||
pmpump3AlmLaser2AlmCurrent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Current Alarm :This
|
||
OID indicates that maximum current
|
||
has reached the internal limitation
|
||
<Help> This alarm indicates if
|
||
the current has reached its limitation
|
||
<Condtype> LASER2_ALM_CURRENT
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3Almlaser2Alarms2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pmAlarms article
|
||
--- *****************************************************
|
||
pmpump3AlmpmAlarms OBJECT IDENTIFIER ::= { pmpump3AlmOtherUrg 74 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmTempHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature High Alarm
|
||
:This OID indicates that the PM
|
||
temperature is higher than the
|
||
alarm threshold <Help> This
|
||
alarm indicates if the module
|
||
temperature is too high <Condtype>
|
||
TEMP_HIGH_ALARM <Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmpmAlarms 2 }
|
||
|
||
|
||
|
||
pmpump3AlmTermpLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature Low Alarm :This
|
||
OID indicates that the PM temperature
|
||
if lower than the alarm threshold
|
||
<Help> This alarm indicates if
|
||
the module temperature is too low
|
||
<Condtype> TERMP_LOW_ALARM <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmpmAlarms 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the pmWarnings article
|
||
--- *****************************************************
|
||
pmpump3AlmpmWarnings OBJECT IDENTIFIER ::= { pmpump3AlmOtherNurg 75 }
|
||
|
||
|
||
|
||
|
||
pmpump3AlmTempHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature High Warning
|
||
:This OID indicates that the PM
|
||
temperature if higher than the
|
||
Warning threshold <Help> This
|
||
warning indicates if the module
|
||
temperature is too high <Condtype>
|
||
TEMP_HIGH_WARNING <Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmpmWarnings 2 }
|
||
|
||
|
||
|
||
pmpump3AlmTermpLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature Low Warning
|
||
:This OID indicates that the PM
|
||
temperature if lower than the Warning
|
||
threshold <Help> This warning
|
||
indicates if the module temperature
|
||
is too low <Condtype> TERMP_LOW_WARNING
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmpump3AlmpmWarnings 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONTROLS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth0 article
|
||
--- *****************************************************
|
||
pmpump3Ctrlsynth0 OBJECT IDENTIFIER ::= { pmpump3CtrlOther 0 }
|
||
|
||
|
||
|
||
|
||
pmpump3CtrlConfClear OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Clear Configuration Tables :This
|
||
bit clears the configuration tables
|
||
from configuration in the flash.
|
||
<Help> This control restores
|
||
the default configuration of the
|
||
module
|
||
"
|
||
::= { pmpump3Ctrlsynth0 13 }
|
||
|
||
|
||
|
||
pmpump3CtrlConfFlash OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Write Configuration Tables :This
|
||
bit saves the current configuration
|
||
of the module as configuration
|
||
in the flash. <Help> This control
|
||
saves the customer configuration
|
||
on the module
|
||
"
|
||
::= { pmpump3Ctrlsynth0 9 }
|
||
|
||
|
||
|
||
pmpump3CtrlConfLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables :When
|
||
set this enables loading from flash
|
||
configuration1 into the module.
|
||
"
|
||
::= { pmpump3Ctrlsynth0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swMgnt article
|
||
--- *****************************************************
|
||
pmpump3CtrlswMgnt OBJECT IDENTIFIER ::= { pmpump3CtrlOther 5 }
|
||
|
||
|
||
|
||
|
||
pmpump3CtrlWarmReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Warm Reset :This OID, when
|
||
set, causes a warm reset of the
|
||
Software. This reset is not traffic
|
||
affecting, and the configuration
|
||
of the Sofwtare remains unchanged.
|
||
<Help> This control initiates
|
||
a warm reset of the module.
|
||
"
|
||
::= { pmpump3CtrlswMgnt 3 }
|
||
|
||
|
||
|
||
pmpump3CtrlColdReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Cold Reset :This OID, when
|
||
set, causes a cold reset of the
|
||
Software. This reset is traffic
|
||
affecting, and the configuration
|
||
of Software is reloaded on start-up.
|
||
<Help> This control initiates
|
||
a cold reset of the module.
|
||
"
|
||
::= { pmpump3CtrlswMgnt 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1LaserOff article
|
||
--- *****************************************************
|
||
pmpump3Ctrllaser1LaserOff OBJECT IDENTIFIER ::= { pmpump3CtrlClient 32 }
|
||
|
||
|
||
|
||
|
||
pmpump3CtrlLaser1LaserOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Laser Off :This
|
||
OID switches OFF the laser of the
|
||
IL1 pump. <Help> This control
|
||
defines the laser state of the
|
||
IL1
|
||
"
|
||
::= { pmpump3Ctrllaser1LaserOff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1EffPwrOutSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmpump3Ctrllaser1EffPwrOutSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Effective Output
|
||
Power :This OID sets the value
|
||
of the effective output power
|
||
of the IL1 pump (Unit = dBm)
|
||
<Help> This control defines
|
||
the IL1 effective output power
|
||
in dBm.
|
||
"
|
||
::= { pmpump3CtrlClient 37 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2LaserOff article
|
||
--- *****************************************************
|
||
pmpump3Ctrllaser2LaserOff OBJECT IDENTIFIER ::= { pmpump3CtrlLine 40 }
|
||
|
||
|
||
|
||
|
||
pmpump3CtrlLaser2LaserOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Preampli / IL2 Pump Laser Off
|
||
:This OID switches OFF the laser
|
||
of the IL2 pump. <Help> This
|
||
control defines the laser state
|
||
of the IL2
|
||
"
|
||
::= { pmpump3Ctrllaser2LaserOff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2EffPwrOutSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmpump3Ctrllaser2EffPwrOutSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Preampli / IL2 Effective Output
|
||
Power :This OID sets the value
|
||
of the effective output power
|
||
of the IL2 pump (Unit = dBm)
|
||
<Help> This control defines
|
||
the IL2 effective output power
|
||
in dBm.
|
||
"
|
||
::= { pmpump3CtrlLine 45 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the ledTest article
|
||
--- *****************************************************
|
||
pmpump3CtrlledTest OBJECT IDENTIFIER ::= { pmpump3CtrlOther 73 }
|
||
|
||
|
||
|
||
|
||
pmpump3CtrlLedOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Leds Off :This OID switches off
|
||
all the Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to OFF
|
||
"
|
||
::= { pmpump3CtrlledTest 3 }
|
||
|
||
|
||
|
||
pmpump3CtrlRedLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Red Leds Test :This OID switches
|
||
on all the red Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to red
|
||
"
|
||
::= { pmpump3CtrlledTest 2 }
|
||
|
||
|
||
|
||
pmpump3CtrlGreenLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Green Leds Test :This OID switches
|
||
on all the green Leds as a test
|
||
feature. <Help> This control
|
||
initiates a test leds turning
|
||
all the LEDs to green
|
||
"
|
||
::= { pmpump3CtrlledTest 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- MEASURES
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1BiasMeas article
|
||
--- *****************************************************
|
||
|
||
pmpump3Mesrlaser1BiasMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Laser Bias
|
||
:This OID gives the pump laser
|
||
current of the IL1 laser (Bias
|
||
= AV/20) (Unit = mA) <Help>
|
||
This measure gives the bias of
|
||
the IL1 pump laser
|
||
"
|
||
::= { pmpump3MesrClient 16 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1VthMeas article
|
||
--- *****************************************************
|
||
|
||
pmpump3Mesrlaser1VthMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Temp. Reg.
|
||
Volt :This OID gives the Voltage
|
||
of the Temperature Regulator of
|
||
the IL1 laser (Voltage = AV/10000)
|
||
(Unit = V) <Help> This measure
|
||
gives the Voltage of the Temperature
|
||
Regulator of the IL1 pump laser
|
||
"
|
||
::= { pmpump3MesrClient 17 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2BiasMeas article
|
||
--- *****************************************************
|
||
|
||
pmpump3Mesrlaser2BiasMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump Laser Bias
|
||
:This OID gives the pump laser
|
||
current of the IL2 laser (Bias
|
||
= AV/20) (Unit = mA) <Help>
|
||
This measure gives the bias of
|
||
the IL2 pump laser
|
||
"
|
||
::= { pmpump3MesrLine 24 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2VthMeas article
|
||
--- *****************************************************
|
||
|
||
pmpump3Mesrlaser2VthMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump Temp. Reg.
|
||
Volt :This OID gives the Voltage
|
||
of the Temperature Regulator of
|
||
the IL2 laser (Voltage = AV/10000)
|
||
(Unit = V) <Help> This measure
|
||
gives the Voltage of the Temperature
|
||
Regulator of the IL2 pump laser
|
||
"
|
||
::= { pmpump3MesrLine 25 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1Pwr article
|
||
--- *****************************************************
|
||
|
||
pmpump3Mesrlaser1Pwr OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Power :This
|
||
OID gives the power value provided
|
||
by the external pump to the IL1
|
||
(Power = AV/20) (Unit = mW) <Help>
|
||
This measure gives the power
|
||
provided by the pump to the IL1
|
||
"
|
||
::= { pmpump3MesrClient 36 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser1Temp article
|
||
--- *****************************************************
|
||
|
||
pmpump3Mesrlaser1Temp OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Booster / IL1 Pump Temperature
|
||
:This OID gives the temperature
|
||
value of the pump linked to the
|
||
IL1 (Temperature = AV/256) (Unit
|
||
= C) <Help> This measure gives
|
||
the temperature value of the pump
|
||
linked to the IL1
|
||
"
|
||
::= { pmpump3MesrClient 37 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2Pwr article
|
||
--- *****************************************************
|
||
|
||
pmpump3Mesrlaser2Pwr OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump Power : This
|
||
OID gives the power value provided
|
||
by the external pump to the IL2
|
||
(Power = AV/20) (Unit = mW) <Help>
|
||
This measure gives the power
|
||
provided by the pump to the IL2
|
||
"
|
||
::= { pmpump3MesrLine 44 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the laser2Temp article
|
||
--- *****************************************************
|
||
|
||
pmpump3Mesrlaser2Temp OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Pre-Amp / IL2 Pump Temperature
|
||
:This OID gives the temperature
|
||
value of the pump linked to the
|
||
IL2 (Temperature = AV/256) (Unit
|
||
= C) <Help> This measure gives
|
||
the temperature value of the pump
|
||
linked to the IL2
|
||
"
|
||
::= { pmpump3MesrLine 45 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the tempMeas article
|
||
--- *****************************************************
|
||
|
||
pmpump3MesrtempMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature :This OID gives
|
||
the temperature of the PM (Temperature
|
||
= AV/256) (Unit = C) <Help>
|
||
This measure gives the temperature
|
||
of the module
|
||
"
|
||
::= { pmpump3MesrOther 74 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONFIG
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group noValue
|
||
--- *****************************************************
|
||
|
||
pmpump3CfgNoValue OBJECT IDENTIFIER ::= { pmpump3Config 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2111
|
||
--- *****************************************************
|
||
|
||
pmpump3tableclientStartup OBJECT IDENTIFIER ::= { pmpump3CfgNoValue 1 }
|
||
|
||
|
||
|
||
pmpump3Cfglaser1Ctrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on IL1 pump Laser
|
||
:This OID configures the default
|
||
initialisation settings on the
|
||
IL1 pump laser.
|
||
"
|
||
::= { pmpump3tableclientStartup 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group lineStartUp
|
||
--- *****************************************************
|
||
|
||
pmpump3CfgLineStartUp OBJECT IDENTIFIER ::= { pmpump3Config 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2191
|
||
--- *****************************************************
|
||
|
||
pmpump3tablelineStartup OBJECT IDENTIFIER ::= { pmpump3CfgLineStartUp 1 }
|
||
|
||
|
||
|
||
pmpump3Cfglaser2Ctrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on IL2 pump Laser
|
||
:This OID configures the default
|
||
initialisation settings on the
|
||
IL2 pump laser.
|
||
"
|
||
::= { pmpump3tablelineStartup 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group labels
|
||
--- *****************************************************
|
||
|
||
pmpump3CfgLabels OBJECT IDENTIFIER ::= { pmpump3Config 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmpump3CfgLabelclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmpump3CfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmpump3CfgLabels 1 }
|
||
|
||
|
||
pmpump3CfgLabelclientEntry OBJECT-TYPE
|
||
SYNTAX Pmpump3CfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmpump3CfgLabelclientIndex }
|
||
::= { pmpump3CfgLabelclientTable 1 }
|
||
|
||
|
||
Pmpump3CfgLabelclientEntry ::=
|
||
SEQUENCE {
|
||
pmpump3CfgLabelclientIndex
|
||
INTEGER,
|
||
pmpump3CfgLabelclientPortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmpump3CfgLabelclientIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelclient
|
||
table
|
||
"
|
||
::= { pmpump3CfgLabelclientEntry 1 }
|
||
|
||
|
||
pmpump3CfgLabelclientPortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the Ports :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the ports.
|
||
"
|
||
::= { pmpump3CfgLabelclientEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmpump3CfgLabellineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Pmpump3CfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmpump3CfgLabels 2 }
|
||
|
||
|
||
pmpump3CfgLabellineEntry OBJECT-TYPE
|
||
SYNTAX Pmpump3CfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmpump3CfgLabellineIndex }
|
||
::= { pmpump3CfgLabellineTable 1 }
|
||
|
||
|
||
Pmpump3CfgLabellineEntry ::=
|
||
SEQUENCE {
|
||
pmpump3CfgLabellineIndex
|
||
INTEGER,
|
||
pmpump3CfgLabellinePortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmpump3CfgLabellineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelline
|
||
table
|
||
"
|
||
::= { pmpump3CfgLabellineEntry 1 }
|
||
|
||
|
||
pmpump3CfgLabellinePortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the lines :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the lines.
|
||
"
|
||
::= { pmpump3CfgLabellineEntry 3 }
|
||
|
||
|
||
|
||
pmpump3CfgWriteConfiguration OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write configuration to module:This OID
|
||
writes the complete configuration to the module"
|
||
::= { pmpump3Config 257 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- TRAP OBJECTS
|
||
--- *****************************************************
|
||
|
||
pmpump3trapBoardNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last module which generates a trap"
|
||
::= { pmpump3traps 4 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- GLOBAL TRAPS
|
||
--- *****************************************************
|
||
|
||
pmpump3Laser2TrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser2Warning, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmpump3AlmLaser2Warning "on", pmpump3trapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Pre-Amp/IL2 Pump of PM PUMP3 in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default is activated"
|
||
::= { pmpump3traps 30 }
|
||
|
||
pmpump3Laser2TrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser2Warning, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM PUMP3 Pre-Amp/IL2 Pump Not Urgent ON"}
|
||
--&MATCH { pmpump3AlmLaser2Warning "on", pmpump3trapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Pre-Amp/IL2 Pump of PM PUMP3 in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default disappeared"
|
||
::= { pmpump3traps 31 }
|
||
|
||
pmpump3Laser2TrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser2Alm, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmpump3AlmLaser2Alm "on", pmpump3trapBoardNumber "$2"}
|
||
--&MESG "DDM Alarms appears on Pre-Amp/IL2 Pump of PM PUMP3 in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default is activated"
|
||
::= { pmpump3traps 32 }
|
||
|
||
pmpump3Laser2TrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser2Alm, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM PUMP3 Pre-Amp/IL2 Pump Urgent ON"}
|
||
--&MATCH { pmpump3AlmLaser2Alm "on", pmpump3trapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Pre-Amp/IL2 Pump of PM PUMP3 in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default disappeared"
|
||
::= { pmpump3traps 33 }
|
||
|
||
pmpump3Laser2TrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser2Fail, pmpump3AlmLaser2HwFail, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmpump3AlmLaser2Fail "on", pmpump3AlmLaser2HwFail "*", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Pre-Amp/IL2 Pump Down on PM PUMP3 in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmpump3AlmLaser2Fail "*", pmpump3AlmLaser2HwFail "on", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Pre-Amp/IL2 Pump Down on PM PUMP3 in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default is activated"
|
||
::= { pmpump3traps 34 }
|
||
|
||
pmpump3Laser2TrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser2Fail, pmpump3AlmLaser2HwFail, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM PUMP3 Pre-Amp/IL2 Pump Fail ON" }
|
||
--&MATCH { pmpump3AlmLaser2Fail "on", pmpump3AlmLaser2HwFail "*", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Pre-Amp/IL2 Pump Up on PM PUMP3 in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmpump3AlmLaser2Fail "*", pmpump3AlmLaser2HwFail "on", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Pre-Amp/IL2 Pump Up on PM PUMP3 in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default disappeared"
|
||
::= { pmpump3traps 35 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- PORTS TRAPS
|
||
--- *****************************************************
|
||
|
||
pmpump3Laser1TrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser1Warning, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Booster/IL1 Pump Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmpump3AlmLaser1Warning "on", pmpump3trapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Booster/IL1 Pump of PM PUMP3 in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent client default is activated"
|
||
::= { pmpump3traps 40 }
|
||
|
||
pmpump3Laser1TrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser1Warning, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Booster/IL1 Pump Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM PUMP3 Booster/IL1 Pump Not Urgent ON"}
|
||
--&MATCH { pmpump3AlmLaser1Warning "on", pmpump3trapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Booster/IL1 Pump of PM PUMP3 in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent client default disappeared"
|
||
::= { pmpump3traps 41 }
|
||
|
||
pmpump3Laser1TrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser1Alm, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Booster/IL1 Pump Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmpump3AlmLaser1Alm "on", pmpump3trapBoardNumber "$2"}
|
||
--&MESG "DDM Alarms appears on Booster/IL1 Pump of PM PUMP3 in slot $2 ($A)"
|
||
DESCRIPTION "Urgent client default is activated"
|
||
::= { pmpump3traps 42 }
|
||
|
||
pmpump3Laser1TrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser1Alm, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Booster/IL1 Pump Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM PUMP3 Booster/IL1 Pump Urgent ON"}
|
||
--&MATCH { pmpump3AlmLaser1Alm "on", pmpump3trapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Booster/IL1 Pump of PM PUMP3 in slot $2 ($A)"
|
||
DESCRIPTION "Urgent client default disappeared"
|
||
::= { pmpump3traps 43 }
|
||
|
||
pmpump3Laser1TrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser1Fail, pmpump3AlmLaser1HwFail, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Booster/IL1 Pump Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmpump3AlmLaser1Fail "on", pmpump3AlmLaser1HwFail "*", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Booster/IL1 Pump Down on PM PUMP3 in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM PUMP3 Booster/IL1 Pump HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmpump3AlmLaser1Fail "*", pmpump3AlmLaser1HwFail "on", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Booster/IL1 Pump Down on PM PUMP3 in Slot $3 ($A)"
|
||
DESCRIPTION "Critical client default is activated"
|
||
::= { pmpump3traps 44 }
|
||
|
||
pmpump3Laser1TrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmLaser1Fail, pmpump3AlmLaser1HwFail, pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Booster/IL1 Pump Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS { "PM PUMP3 Booster/IL1 Pump Fail ON" }
|
||
--&MATCH { pmpump3AlmLaser1Fail "on", pmpump3AlmLaser1HwFail "*", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Booster/IL1 Pump Up on PM PUMP3 in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM PUMP3 Booster/IL1 Pump HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmpump3AlmLaser1Fail "*", pmpump3AlmLaser1HwFail "on", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Booster/IL1 Pump Up on PM PUMP3 in Slot $3 ($A)"
|
||
DESCRIPTION "Critical client default disappeared"
|
||
::= { pmpump3traps 45 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- HW TRAPS
|
||
--- *****************************************************
|
||
|
||
pmpump3PowerTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmDefFuseB, pmpump3AlmDefFuseA , pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Fuse A Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmpump3AlmDefFuseB "*", pmpump3AlmDefFuseA "on", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Power Input A Fail on PM PUMP3 in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PM PUMP3 Fuse B Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmpump3AlmDefFuseB "on", pmpump3AlmDefFuseA "*", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Power Input B Fail on PM PUMP3 in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default is activated"
|
||
::= { pmpump3traps 50 }
|
||
pmpump3PowerTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmpump3AlmDefFuseB, pmpump3AlmDefFuseA , pmpump3trapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PM PUMP3 Fuse A&B Fail OFF"
|
||
--&ACTIONS { log, normal}
|
||
--&CLEARS { "PM PUMP3 Fuse A Fail ON", "PM PUMP3 Fuse B Fail ON" }
|
||
--&MATCH { pmpump3AlmDefFuseB "on", pmpump3AlmDefFuseA "on", pmpump3trapBoardNumber "$3"}
|
||
--&MESG "Power Inputs A and B Present on PM PUMP3 in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default disappeared"
|
||
::= { pmpump3traps 51 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
END
|