-- EKINOPS-pmoab.TXT: MIB
--
--MIB Part Number:3MI00202AJAD
--MIB Version:01
--
-- Copyright (c) 2016 by Ekinops
-- All rights reserved.
--
-- *****************************************************************
EKINOPS-PmOab-MIB DEFINITIONS ::= BEGIN
IMPORTS
ekinops,
EkiState,
EkiOnOff,
EkiMode,
EkiProtocol,
EkiApiState,
EkiSynchroMode,
EkiMeasureType
FROM EKINOPS-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32,
Counter32,
IpAddress
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
modulepmoab MODULE-IDENTITY
LAST-UPDATED "201605230000Z"
ORGANIZATION "Ekinops"
CONTACT-INFO
"Ekinops
3, rue Blaise Pascal
F-22300 Lannion / FRANCE
Tel : +33 (0)2 96 05 00 30
Fax : +33 (0)2 96 48 62 39
E-mail: support@ekinops.net"
DESCRIPTION
"MIB for the Ekinops pmoab hardware."
REVISION "200702070000Z"
DESCRIPTION
"Initial Version."
REVISION "200707060000Z"
DESCRIPTION
"°C changed to C"
REVISION "200711210000Z"
DESCRIPTION
"Update Ekinops address, Helps on objects, Ports labels"
REVISION "200904150000Z"
DESCRIPTION
"Add ext Pumps features"
REVISION "200909210000Z"
DESCRIPTION
"Add CondType parameters"
REVISION "200912140000Z"
DESCRIPTION
"Correction on traps"
REVISION "201002250000Z"
DESCRIPTION
"Probcause,AlarmType - NMS"
REVISION "201007150000Z"
DESCRIPTION
"Add inventory object for the NMS"
REVISION "201010290000Z"
DESCRIPTION
"Formula in comments, Objetcs removal"
REVISION "201011030000Z"
DESCRIPTION
"Modify inventory object for the NMS"
REVISION "201207040000Z"
DESCRIPTION
"Minor cosmetic updates"
REVISION "201403260000Z"
DESCRIPTION
"Probcause,AlarmType - NMS completion"
REVISION "201412100000Z"
DESCRIPTION
"Labels cosmetic updates"
REVISION "201605230000Z"
DESCRIPTION
"New AlarmType synthesisAlarm (12)"
::= { ekinops 23 }
--- *****************************************************
--- LEAF LEVEL 2
--- *****************************************************
pmoabalarms OBJECT IDENTIFIER ::= { modulepmoab 2 }
pmoabAlmOther OBJECT IDENTIFIER ::= { pmoabalarms 1 }
pmoabAlmOtherNurg OBJECT IDENTIFIER ::= { pmoabAlmOther 1 }
pmoabAlmOtherUrg OBJECT IDENTIFIER ::= { pmoabAlmOther 2 }
pmoabAlmOtherCrit OBJECT IDENTIFIER ::= { pmoabAlmOther 3 }
pmoabAlmClient OBJECT IDENTIFIER ::= { pmoabalarms 2 }
pmoabAlmClientNurg OBJECT IDENTIFIER ::= { pmoabAlmClient 1 }
pmoabAlmClientUrg OBJECT IDENTIFIER ::= { pmoabAlmClient 2 }
pmoabAlmClientCrit OBJECT IDENTIFIER ::= { pmoabAlmClient 3 }
pmoabAlmLine OBJECT IDENTIFIER ::= { pmoabalarms 3 }
pmoabAlmLineNurg OBJECT IDENTIFIER ::= { pmoabAlmLine 1 }
pmoabAlmLineUrg OBJECT IDENTIFIER ::= { pmoabAlmLine 2 }
pmoabAlmLineCrit OBJECT IDENTIFIER ::= { pmoabAlmLine 3 }
pmoabmeasures OBJECT IDENTIFIER ::= { modulepmoab 3 }
pmoabMesrOther OBJECT IDENTIFIER ::= { pmoabmeasures 1 }
pmoabMesrClient OBJECT IDENTIFIER ::= { pmoabmeasures 2 }
pmoabMesrLine OBJECT IDENTIFIER ::= { pmoabmeasures 3 }
pmoabcontrolsWrite OBJECT IDENTIFIER ::= { modulepmoab 6 }
pmoabCtrlOther OBJECT IDENTIFIER ::= { pmoabcontrolsWrite 1 }
pmoabCtrlClient OBJECT IDENTIFIER ::= { pmoabcontrolsWrite 2 }
pmoabCtrlLine OBJECT IDENTIFIER ::= { pmoabcontrolsWrite 3 }
pmoabri OBJECT IDENTIFIER ::= { modulepmoab 7 }
pmoabConfig OBJECT IDENTIFIER ::= { modulepmoab 9 }
pmoabtraps OBJECT IDENTIFIER ::= { modulepmoab 10 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- TEXTUAL-CONVENTION
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
PmoabboosterMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Different modes on OA booster"
SYNTAX INTEGER {
oaboosterdefaultmode(0),
oaboosterconstantcurrentmode(1),
oaboosterconstantpowermode(2)
}
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- REMOTE INVENTORY
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
pmoabRinvReloadInventory OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the inventory: This OID triggers an
inventory reload."
::= { pmoabri 2 }
pmoabRinvModulePlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module platform description: This OID contains the
description of the Module."
::= { pmoabri 3 }
pmoabRinvSwPlatform OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SW platform description: This OID contains the
description of the Software platform."
::= { pmoabri 4 }
pmoabRinvSwFoa OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical device driver description: This OID contains
the description of the driver of the optical devices
(Booster and Pre-Amp)"
::= { pmoabri 5 }
pmoabRinvBoosterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoabRinvBoosterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of the Boosters on the selected module"
::= { pmoabri 6 }
pmoabRinvBoosterEntry OBJECT-TYPE
SYNTAX PmoabRinvBoosterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the Boosters table"
INDEX { pmoabRinvBoosterIndex }
::= { pmoabRinvBoosterTable 1 }
PmoabRinvBoosterEntry::=
SEQUENCE {
pmoabRinvBoosterIndex
Integer32,
pmoabRinvBooster
DisplayString
}
pmoabRinvBoosterIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for Booster table"
::= { pmoabRinvBoosterEntry 1 }
pmoabRinvBooster OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Inventory for the Booster: This OID contains the inventory for the Booster"
::= { pmoabRinvBoosterEntry 2 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- ALARMS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synthAlm0 article
--- *****************************************************
pmoabAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoabAlmOtherCrit 0 }
pmoabAlmDefFuseB OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse B Fail :This OID indicates
that the fuse of the power input
B is in fail condition <Help>
Status of the Fuse B <Condtype>
DEF_FUSE_B <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmsynthAlm0 16 }
pmoabAlmDefFuseA OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Fuse A Fail :This OID indicates
that the fuse of the power input
A is in fail condition <Help>
Status of the Fuse A <Condtype>
DEF_FUSE_A <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmsynthAlm0 15 }
pmoabAlmExtPumpNotLocked OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
External Pump1 Not Detected :This
OID indicates that the first external
pump is not detected by the amplifier
module <Help> This alarm indicates
if the first external pump is detected
by the amplifier module <Condtype>
EXT_PUMP_NOT_LOCKED <Probcause>
pumpFailure (39) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmsynthAlm0 12 }
pmoabAlmDwEdfaInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Pre-Amp Not Initialized :This
OID indicates that the initialisation
of the Pre-Amp is not completed
<Condtype> DW_EDFA_INIT_NOT_COMPL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoabAlmsynthAlm0 11 }
pmoabAlmUpEdfaInitNotCompl OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Not Initialized :This
OID indicates that the initialisation
of the Booster is not completed
<Help> This status indicates
if the Booster has been correctly
initialized <Condtype> UP_EDFA_INIT_NOT_COMPL
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoabAlmsynthAlm0 10 }
pmoabAlmModGlobFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Failure :This OID is set
on detection of a failure originating
from the PM <Condtype> MOD_GLOB_FAIL
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoabAlmsynthAlm0 9 }
pmoabAlmMaintenanceMode OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Maintenance Mode :This OID indicates
that the PM is in maintenance mode
<Help> This status indiates if
the module is currently in maintenance
mode <Condtype> MAINTENANCE_MODE
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoabAlmsynthAlm0 1 }
--- *****************************************************
--- LEAF for the synthAlm2 article
--- *****************************************************
pmoabAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoabAlmOtherNurg 2 }
pmoabAlmConfTableLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Load :This OID
is at 1 during the loading of
configuration tables in the modules
RAM. <Condtype> CONF_TABLE_LOAD
<Probcause> other (1) <Alarmtype>
other (1) <Polarity> (2)
"
::= { pmoabAlmsynthAlm2 3 }
pmoabAlmInvUpload OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Inventory Upload :This OID is
at 1 during the uploading of PM
inventory information. <Condtype>
INV_UPLOAD <Probcause> other (1)
<Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoabAlmsynthAlm2 2 }
pmoabAlmConfTableSave OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
PM Configuration Save :This OID
is at 1 during the saving of a
new configuration table in the
module Flash memory. <Condtype>
CONF_TABLE_SAVE <Probcause> other
(1) <Alarmtype> other (1) <Polarity>
(2)
"
::= { pmoabAlmsynthAlm2 1 }
--- *****************************************************
--- LEAF for the synthAlm7 article
--- *****************************************************
pmoabAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoabAlmLineCrit 7 }
pmoabAlmLineFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port Failure :This OID indicates
a failure on the line port <Condtype>
LINE_FAIL <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoabAlmsynthAlm7 12 }
pmoabAlmLineDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Line Optical Module DDM
:This OID indicates an alarm is
present coming out of Line optical
interface DDM <Condtype> LINE_DDM_ALM
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoabAlmsynthAlm7 10 }
pmoabAlmLineDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Line Optical Module
DDM :This OID indicates a warning
is present coming out of Line optical
interface DDM <Condtype> LINE_DDM_WARNING
<Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoabAlmsynthAlm7 9 }
pmoabAlmLineTxOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Optical Output Shutdown
:This OID indicates the Booster
optical output power is on <Help>
This status indicates if the Booster
laser pump is ON or OFF <Condtype>
LINE_TX_OFF <Probcause> other (1)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoabAlmsynthAlm7 5 }
pmoabAlmLineHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Condtype> LINE_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoabAlmsynthAlm7 4 }
--- *****************************************************
--- LEAF for the synthAlm8 article
--- *****************************************************
pmoabAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoabAlmClientCrit 8 }
pmoabAlmClientFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Port Failure :This OID
indicates a failure on the Client
port <Condtype> CLIENT_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoabAlmsynthAlm8 12 }
pmoabAlmClientDdmAlm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Alarm On Client Optical Module
DDM :This OID indicates an alarm
is present coming out of Client
optical interface DDM <Condtype>
CLIENT_DDM_ALM <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
"
::= { pmoabAlmsynthAlm8 10 }
pmoabAlmClientDdmWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Warning On Client Optical Module
DDM :This OID indicates a warning
is present coming out of Client
optical interface DDM <Condtype>
CLIENT_DDM_WARNING <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoabAlmsynthAlm8 9 }
pmoabAlmClientHwFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Client Port HW Failure :This OID
indicates a failure on Client port,
most probably caused by a HW issue
<Condtype> CLIENT_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
"
::= { pmoabAlmsynthAlm8 4 }
--- *****************************************************
--- LEAF for the clientEdfaAlarms1 article
--- *****************************************************
pmoabAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabAlmClientUrg 32 }
pmoabAlmClientInputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Pwr High Alarm :This
OID indicates that the Receive
Power is higher than the alarm
theshold of the Booster Optical
Module <Help> This alarm indicates
if the Booster rx power is too
high <Condtype> CLIENT_INPUT_PWR_HIGH_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoabAlmclientEdfaAlarms1 4 }
pmoabAlmClientInputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Pwr Low Alarm :This
OID indicates that the Receive
Power is lower than the alarm
theshold of the Booster Optical
Module <Help> This alarm indicates
if the Booster rx power is too
low <Condtype> CLIENT_INPUT_PWR_LOW_ALARM
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoabAlmclientEdfaAlarms1 3 }
--- *****************************************************
--- LEAF for the clientEdfaWarnings article
--- *****************************************************
pmoabAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoabAlmClientNurg 33 }
pmoabAlmClientInputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Pwr High Warning :This
OID indicates that the Receive
Power is higher than the Warning
theshold of the Booster Optical
Module <Help> This warning indicates
if the Booster rx power is too
high <Condtype> CLIENT_INPUT_PWR_HIGH_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoabAlmclientEdfaWarnings 4 }
pmoabAlmClientInputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Pwr Low Warning :This
OID indicates that the Receive
Power is lower than the Warning
theshold of the Booster Optical
Module <Help> This warning indicates
if the Booster rx power is too
low <Condtype> CLIENT_INPUT_PWR_LOW_WARNING
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
"
::= { pmoabAlmclientEdfaWarnings 3 }
--- *****************************************************
--- LEAF for the clientEdfaAlarms2 article
--- *****************************************************
pmoabAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabAlmClientCrit 35 }
pmoabAlmClientEdfaLos OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Loss Of Signal :This OID
indicates a Loss of Signal on the
Booster Optical Module <Help>
This alarm indicates if an optical
signal is detected on the Booster
input <Condtype> CLIENT_EDFA_LOS
<Probcause> receiveFailure (41)
<Alarmtype> physicalViolation (9)
<Polarity> (2)
"
::= { pmoabAlmclientEdfaAlarms2 4 }
--- *****************************************************
--- LEAF for the lineEdfaAlarms1 article
--- *****************************************************
pmoabAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabAlmLineUrg 40 }
pmoabAlmLineBiasHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Bias High Alarm :This
OID indicates that the Bias is
higher than the alarm theshold
of the Booster Optical Module
<Help> This alarm indicates
if the Booster bias is too high
<Condtype> LINE_BIAS_HIGH_ALARM
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms1 8 }
pmoabAlmLineBiasLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Bias Low Alarm :This OID
indicates that the Bias is lower
than the alarm theshold of the
Booster Optical Module <Help>
This alarm indicates if the Booster
bias is too low <Condtype> LINE_BIAS_LOW_ALARM
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms1 7 }
pmoabAlmLineOutputPwrHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Pwr High Alarm :This
OID indicates that the Transmit
Power is higher than the alarm
theshold of the Booster Optical
Module <Help> This alarm indicates
if the Booster tx power is too
high <Condtype> LINE_OUTPUT_PWR_HIGH_ALARM
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms1 6 }
pmoabAlmLineOutputPwrLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Pwr Low Alarm :This
OID indicates that the Transmit
Power is lower than the alarm theshold
of the Booster Optical Module
<Help> This alarm indicates if
the Booster tx power is too low
<Condtype> LINE_OUTPUT_PWR_LOW_ALARM
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms1 5 }
pmoabAlmLineGainHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain High Alarm :This
OID indicates that the Gain is
higher than the alarm threshold
of the Booster Module <Help>
This alarm indicates if the Booster
gain is too high <Condtype> LINE_GAIN_HIGH_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms1 2 }
pmoabAlmLineGainLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain Low Alarm :This OID
indicates that the Gain is lower
than the alarm theshold of the
Booster Module <Help> This alarm
indicates if the Booster gain is
too low <Condtype> LINE_GAIN_LOW_ALARM
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms1 1 }
--- *****************************************************
--- LEAF for the lineEdfaWarnings article
--- *****************************************************
pmoabAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoabAlmLineNurg 41 }
pmoabAlmLineBiasHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Bias High Warning :This
OID indicates that the Bias is
higher than the Warning theshold
of the Booster Optical Module
<Help> This warning indicates
if the Booster bias is too high
<Condtype> LINE_BIAS_HIGH_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaWarnings 8 }
pmoabAlmLineBiasLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Bias Low Warning :This
OID indicates that the Bias is
lower than the Warning theshold
of the Booster Optical Module
<Help> This warning indicates
if the Booster bias is too low
<Condtype> LINE_BIAS_LOW_WARNING
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaWarnings 7 }
pmoabAlmLineOutputPwrHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Pwr High Warning :This
OID indicates that the Transmit
Power is higher than the Warning
theshold of the Booster Optical
Module <Help> This warning indicates
if the Booster tx power is too
high <Condtype> LINE_OUTPUT_PWR_HIGH_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaWarnings 6 }
pmoabAlmLineOutputPwrLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Pwr Low Warning :This
OID indicates that the Transmit
Power is lower than the Warning
theshold of the Booster Optical
Module <Help> This warning indicates
if the Booster tx power is too
low <Condtype> LINE_OUTPUT_PWR_LOW_WARNING
<Probcause> transmitterFailure
(56) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaWarnings 5 }
pmoabAlmLineGainHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain High Warning :This
OID indicates that the Gain is
higher than the Warning threshold
of the Booster Module <Help>
This alarm indicates if the Booster
gain is too high <Condtype> LINE_GAIN_HIGH_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaWarnings 2 }
pmoabAlmLineGainLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain Low Warning :This
OID indicates that the Gain is
lower than the Warning theshold
of the Booster Module <Help>
This alarm indicates if the Booster
gain is too low <Condtype> LINE_GAIN_LOW_WARNING
<Probcause> performanceDegraded
(35) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaWarnings 1 }
--- *****************************************************
--- LEAF for the lineEdfaAlarms2 article
--- *****************************************************
pmoabAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabAlmLineCrit 43 }
pmoabAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster External Pump1 Low Current
:This OID indicates that the EDFA
pump current of the first external
pump linked to the Booster is too
low <Help> This alarm indicates
that the EDFA pump current of the
first external pump linked to the
Booster is too low. <Condtype>
LINE_EXT_PUMP_EDFA_LOW_CURRENT
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms2 5 }
pmoabAlmLineEdfaLaserFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Pump Laser Fail :This
OID indicates a Transmit Laser
Fail on the Booster Optical Module
<Help> This alarm indicates if
the laser of the Booster is in
fail condition <Condtype> LINE_EDFA_LASER_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms2 3 }
pmoabAlmLineEdfaTecFail OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster TEC Fail :This OID indicates
that the TEC is in fail condition
on the Booster Optical Module
<Help> This alarm indicates if
the TEC of the Booster is in fail
condition <Condtype> LINE_EDFA_TEC_FAIL
<Probcause> pumpFailure (39) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms2 2 }
pmoabAlmLineEdfaNr OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Optical Module Not Ready
:This OID indicates that the Booster
Optical Module is not ready <Help>
This status indicates if the Booster
has been correctly initialized
<Condtype> LINE_EDFA_NR <Probcause>
equipmentMalfunction (16) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmlineEdfaAlarms2 1 }
--- *****************************************************
--- LEAF for the foaAlarms article
--- *****************************************************
pmoabAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoabAlmOtherUrg 74 }
pmoabAlmTempHighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature High Alarm :This OID
indicates that the PM temperature
is higher than the alarm threshold
<Condtype> TEMP_HIGH_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmfoaAlarms 8 }
pmoabAlmTermpLowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature Low Alarm :This OID
indicates that the PM temperature
if lower than the alarm threshold
<Condtype> TERMP_LOW_ALARM <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmfoaAlarms 7 }
pmoabAlm3v3HighAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
3V3 High Alarm :This OID indicates
that the PM 3V3 voltage is higher
than the alarm threshold <Condtype>
3V3_HIGH_ALARM <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmfoaAlarms 6 }
pmoabAlm3v3LowAlarm OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
3V3 Low Alarm :This OID indicates
that the PM 3V3 voltage is lower
than the alarm threshold <Condtype>
3V3_LOW_ALARM <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmfoaAlarms 5 }
--- *****************************************************
--- LEAF for the foaWarnings article
--- *****************************************************
pmoabAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoabAlmOtherNurg 75 }
pmoabAlmTempHighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature High Warning :This
OID indicates that the PM temperature
if higher than the Warning threshold
<Condtype> TEMP_HIGH_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmfoaWarnings 8 }
pmoabAlmTermpLowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Temperature Low Warning :This
OID indicates that the PM temperature
if lower than the Warning threshold
<Condtype> TERMP_LOW_WARNING <Probcause>
temperatureUnacceptable (51) <Alarmtype>
equipmentAlarm (5) <Polarity> (2)
"
::= { pmoabAlmfoaWarnings 7 }
pmoabAlm3v3HighWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
3V3 High Warning :This OID indicates
that the PM 3V3 voltage is higher
than the Warning threshold <Condtype>
3V3_HIGH_WARNING <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmfoaWarnings 6 }
pmoabAlm3v3LowWarning OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
3V3 Low Warning :This OID indicates
that the PM 3V3 voltage is lower
than the Warning threshold <Condtype>
3V3_LOW_WARNING <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <Polarity> (2)
"
::= { pmoabAlmfoaWarnings 5 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONTROLS
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the synth0 article
--- *****************************************************
pmoabCtrlsynth0 OBJECT IDENTIFIER ::= { pmoabCtrlOther 0 }
pmoabCtrlConfClear OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear Configuration Tables :This
bit clears the configuration tables
from configuration in the flash.
<Help> This control restores
the default configuration of the
module
"
::= { pmoabCtrlsynth0 13 }
pmoabCtrlConfFlash OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Write Configuration Tables :This
bit saves the current configuration
of the module as configuration
in the flash. <Help> This control
saves the customer configuration
on the module
"
::= { pmoabCtrlsynth0 9 }
pmoabCtrlConfLoad OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Load Configuration Tables :When
set this enables loading from flash
configuration1 into the module.
"
::= { pmoabCtrlsynth0 1 }
--- *****************************************************
--- LEAF for the swMgnt article
--- *****************************************************
pmoabCtrlswMgnt OBJECT IDENTIFIER ::= { pmoabCtrlOther 5 }
pmoabCtrlWarmReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Warm Reset :This OID, when
set, causes a warm reset of the
Software. This reset is not traffic
affecting, and the configuration
of the Sofwtare remains unchanged.
<Help> This control initiates
a warm reset of the module.
"
::= { pmoabCtrlswMgnt 3 }
pmoabCtrlColdReset OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
PM Cold Reset :This OID, when
set, causes a cold reset of the
Software. This reset is traffic
affecting, and the configuration
of Software is reloaded on start-up.
<Help> This control initiates
a cold reset of the module.
"
::= { pmoabCtrlswMgnt 2 }
--- *****************************************************
--- LEAF for the lineEdfaLaserOff article
--- *****************************************************
pmoabCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoabCtrlLine 40 }
pmoabCtrlLineEdfaLaserOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Pump Laser Shutdown :This
OID switches OFF the laser of the
Booster Optical Module <Help>
This control defines the laser
state of the Booster
"
::= { pmoabCtrllineEdfaLaserOff 1 }
--- *****************************************************
--- LEAF for the lineEdfaMode article
--- *****************************************************
pmoabCtrllineEdfaMode OBJECT-TYPE
SYNTAX PmoabboosterMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Module Mode :This OID
selects the mode of the Booster
Module <Help> This control defines
the Booster Mode (0: Default mode,
2:Constant output power)
"
::= { pmoabCtrlLine 41 }
--- *****************************************************
--- LEAF for the lineIlasSettingValue article
--- *****************************************************
pmoabCtrllineIlasSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Laser Current Value :This
OID sets the value of the laser
current of the Booster Module (active
only in constant current mode)
(AV = Current *100) (Unit = mA)
<Help> This control defines the
Booster Laser current in mA (valid
only in constant current mode)
"
::= { pmoabCtrlLine 42 }
--- *****************************************************
--- LEAF for the linePlasSettingValue article
--- *****************************************************
pmoabCtrllinePlasSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Pump Power Value :This
OID sets the value of the laser
power of the Booster Optical Module
(active only in constant power
mode) (AV=(Power/0,005) + 32768)
(Unit = dBm) <Help> This control
defines the Booster laser power
in dBm (valid only in constant
output power mode)
"
::= { pmoabCtrlLine 43 }
--- *****************************************************
--- LEAF for the lineGainSettingValue article
--- *****************************************************
pmoabCtrllineGainSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Gain Value :This OID sets
the value of the gain of the Booster
Module (active only in constant
gain mode) (AV=(Gain/0,005) + 32768)
(Unit = dB)
"
::= { pmoabCtrlLine 44 }
--- *****************************************************
--- LEAF for the lineEffPwrOutSettingValue article
--- *****************************************************
pmoabCtrllineEffPwrOutSettingValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Booster Effective Output Power
:This OID sets the value of the
effective output power (without
noise power) of the Booster Module
(active only in input power function
mode) (AV=(Power/0,005) + 32768)
(Unit = dBm)
"
::= { pmoabCtrlLine 45 }
--- *****************************************************
--- LEAF for the powerDown article
--- *****************************************************
pmoabCtrlpowerDown OBJECT IDENTIFIER ::= { pmoabCtrlOther 72 }
pmoabCtrlSoftPowerDown OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Module Software Shutdown :This
OID shuts down the PM Software
<Help> This control initiates
a shut down of software.
"
::= { pmoabCtrlpowerDown 1 }
--- *****************************************************
--- LEAF for the ledTest article
--- *****************************************************
pmoabCtrlledTest OBJECT IDENTIFIER ::= { pmoabCtrlOther 73 }
pmoabCtrlLedOff OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Leds Off :This OID switches off
all the Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to OFF
"
::= { pmoabCtrlledTest 3 }
pmoabCtrlRedLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Red Leds Test :This OID switches
on all the red Leds as a test feature.
<Help> This control initiates
a test leds turning all the LEDs
to red
"
::= { pmoabCtrlledTest 2 }
pmoabCtrlGreenLed OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Green Leds Test :This OID switches
on all the green Leds as a test
feature. <Help> This control
initiates a test leds turning
all the LEDs to green
"
::= { pmoabCtrlledTest 1 }
--- *****************************************************
--- LEAF for the maintMode article
--- *****************************************************
pmoabCtrlmaintMode OBJECT IDENTIFIER ::= { pmoabCtrlOther 75 }
pmoabCtrlMaintenance OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Module Maintenance Mode :This
OID sets the PM in maintenance
mode <Help> This control enables
the maintenance mode of the module
"
::= { pmoabCtrlmaintMode 1 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- MEASURES
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the clientEdfaRxpwrMeas article
--- *****************************************************
pmoabMesrclientEdfaRxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Rx Power :This OID gives
the receive power value of the
Booster Optical Module (Power
=(AV-32768)*0,005) (Unit = dBm)
<Help> This measure gives the
Rx optical power of the Booster
"
::= { pmoabMesrClient 34 }
--- *****************************************************
--- LEAF for the lineEdfaBiasMeas article
--- *****************************************************
pmoabMesrlineEdfaBiasMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Pump Laser Current :This
OID gives the pump laser current
of the Booster Optical Module (Current
=AV/100) (Unit = mA) <Help> This
measure gives the bias of the Booster
pump laser
"
::= { pmoabMesrLine 40 }
--- *****************************************************
--- LEAF for the lineEdfaTxpwrMeas article
--- *****************************************************
pmoabMesrlineEdfaTxpwrMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Tx Power :This OID gives
the transmit power value of the
Booster Optical Module (Power =(AV-32768)*0,005)
(Unit = dBm) <Help> This measure
gives the Tx optical power of the
Booster
"
::= { pmoabMesrLine 41 }
--- *****************************************************
--- LEAF for the lineEdfaGainMeas article
--- *****************************************************
pmoabMesrlineEdfaGainMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Booster Gain :This OID gives the
gain value of the Booster Module
(Gain =(AV-32768)*0,005) (Unit
= dB) <Help> This measure gives
the optical gain of the Booster
"
::= { pmoabMesrLine 43 }
--- *****************************************************
--- LEAF for the tempMeas article
--- *****************************************************
pmoabMesrtempMeas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module Temperature :This OID gives
the temperature of the PM (Unit
= C) <Help> This measure gives
the temperature of the module
"
::= { pmoabMesrOther 72 }
--- *****************************************************
--- LEAF for the 3v3Meas article
--- *****************************************************
pmoabMesr3v3Meas OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Module 3.3 Voltage :This OID gives
the 3V3 voltage of the PM (Unit
= V) <Help> This measure gives
the 3V3 voltage of the module
"
::= { pmoabMesrOther 73 }
--- *****************************************************
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- CONFIG
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
--- *****************************************************
--- *****************************************************
--- LEAF for the table Group noValue
--- *****************************************************
pmoabCfgNoValue OBJECT IDENTIFIER ::= { pmoabConfig 1 }
--- *****************************************************
--- LEAF for the table 2111
--- *****************************************************
pmoabtableclientStartup OBJECT IDENTIFIER ::= { pmoabCfgNoValue 1 }
--- *****************************************************
--- LEAF for the table Group lineStartUp
--- *****************************************************
pmoabCfgLineStartUp OBJECT IDENTIFIER ::= { pmoabConfig 2 }
--- *****************************************************
--- LEAF for the table 2191
--- *****************************************************
pmoabtablelineStartup OBJECT IDENTIFIER ::= { pmoabCfgLineStartUp 1 }
pmoabCfglineEdfaLaserCtrl OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line Laser
:This OID configures the default
initialisation settings on the
line laser.
"
::= { pmoabtablelineStartup 2 }
pmoabCfglineEdfaLaserMode OBJECT-TYPE
SYNTAX Unsigned32 (0..65536)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default Settings on Line mode
:This OID configures the default
mode on the line amplifier.
"
::= { pmoabtablelineStartup 3 }
--- *****************************************************
--- LEAF for the table Group labels
--- *****************************************************
pmoabCfgLabels OBJECT IDENTIFIER ::= { pmoabConfig 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmoabCfgLabelclientTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoabCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmoabCfgLabels 1 }
pmoabCfgLabelclientEntry OBJECT-TYPE
SYNTAX PmoabCfgLabelclientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmoabCfgLabelclientIndex }
::= { pmoabCfgLabelclientTable 1 }
PmoabCfgLabelclientEntry ::=
SEQUENCE {
pmoabCfgLabelclientIndex
INTEGER,
pmoabCfgLabelclientPortn
DisplayString
}
pmoabCfgLabelclientIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelclient
table
"
::= { pmoabCfgLabelclientEntry 1 }
pmoabCfgLabelclientPortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
"
::= { pmoabCfgLabelclientEntry 3 }
--- *****************************************************
--- LEAF for the table NO_VALUE
--- *****************************************************
pmoabCfgLabellineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PmoabCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
List of Article
"
::= { pmoabCfgLabels 2 }
pmoabCfgLabellineEntry OBJECT-TYPE
SYNTAX PmoabCfgLabellineEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Row definition for the labels
table
"
INDEX { pmoabCfgLabellineIndex }
::= { pmoabCfgLabellineTable 1 }
PmoabCfgLabellineEntry ::=
SEQUENCE {
pmoabCfgLabellineIndex
INTEGER,
pmoabCfgLabellinePortn
DisplayString
}
pmoabCfgLabellineIndex OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
Index definition for the labelline
table
"
::= { pmoabCfgLabellineEntry 1 }
pmoabCfgLabellinePortn OBJECT-TYPE
SYNTAX DisplayString( SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
"
::= { pmoabCfgLabellineEntry 3 }
pmoabCfgWriteConfiguration OBJECT-TYPE
SYNTAX EkiOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write configuration to module:This OID
writes the complete configuration to the module"
::= { pmoabConfig 257 }
--- *****************************************************
--- TRAP OBJECTS
--- *****************************************************
pmoabtrapBoardNumber OBJECT-TYPE
SYNTAX INTEGER(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last module which generates a trap"
::= { pmoabtraps 4 }
--- *****************************************************
--- GLOBAL TRAPS
--- *****************************************************
pmoabLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoabAlmLineDdmWarning, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Line Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmoabAlmLineDdmWarning "on", pmoabtrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Booster Output of PMOA-B in slot $2 ($A)"
DESCRIPTION "Not urgent Line default is activated"
::= { pmoabtraps 30 }
pmoabLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoabAlmLineDdmWarning, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Line Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAB Line Not Urgent ON"}
--&MATCH { pmoabAlmLineDdmWarning "on", pmoabtrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Booster Output of PMOA-B in slot $2 ($A)"
DESCRIPTION "Not urgent Line default disappeared"
::= { pmoabtraps 31 }
pmoabLineTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoabAlmLineDdmAlm, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Line Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmoabAlmLineDdmAlm "on", pmoabtrapBoardNumber "$2"}
--&MESG "DDM Alarm appears on Booster Output of PMOA-B in slot $2 ($A)"
DESCRIPTION "Urgent Line default is activated"
::= { pmoabtraps 32 }
pmoabLineTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoabAlmLineDdmAlm, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Line Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAB Line Urgent ON"}
--&MATCH { pmoabAlmLineDdmAlm "on", pmoabtrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Booster Output of PMOA-B in slot $2 ($A)"
DESCRIPTION "Urgent Line default disappeared"
::= { pmoabtraps 33 }
pmoabLineTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmoabAlmLineFail, pmoabAlmLineHwFail, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Line Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmoabAlmLineFail "on", pmoabAlmLineHwFail "*", pmoabtrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Booster Output of PMOA-B in slot $3 ($A)"
--&FILTNAME "PMOAB Line HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoabAlmLineFail "*", pmoabAlmLineHwFail "on", pmoabtrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Booster Output of PMOA-B in slot $3 ($A)"
DESCRIPTION "Critical Line default is activated"
::= { pmoabtraps 34 }
pmoabLineTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmoabAlmLineFail, pmoabAlmLineHwFail, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Line Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAB Line Fail ON"}
--&MATCH { pmoabAlmLineFail "on", pmoabAlmLineHwFail "*", pmoabtrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Booster Output of PMOA-B in slot $3 ($A)"
--&FILTNAME "PMOAB Line HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoabAlmLineFail "*", pmoabAlmLineHwFail "on", pmoabtrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Booster Output of PMOA-B in slot $3 ($A)"
DESCRIPTION "Critical Line default disappeared"
::= { pmoabtraps 35 }
--- *****************************************************
--- PORTS TRAPS
--- *****************************************************
pmoabClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoabAlmClientDdmWarning, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Client Not Urgent ON"
--&ACTIONS { log, minor }
--&MATCH { pmoabAlmClientDdmWarning "on", pmoabtrapBoardNumber "$2"}
--&MESG "DDM Warning appears on Booster input of PMOA-B in slot $2 ($A)"
DESCRIPTION "Not urgent client default is activated"
::= { pmoabtraps 40 }
pmoabClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoabAlmClientDdmWarning, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Client Not Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAB Client Not Urgent ON"}
--&MATCH { pmoabAlmClientDdmWarning "on", pmoabtrapBoardNumber "$2"}
--&MESG "DDM Warning disappears on Booster input of PMOA-B in slot $2 ($A)"
DESCRIPTION "Not urgent client default disappeared"
::= { pmoabtraps 41 }
pmoabClientTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoabAlmClientDdmAlm, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Client Urgent ON"
--&ACTIONS { log, major }
--&MATCH { pmoabAlmClientDdmAlm "on", pmoabtrapBoardNumber "$2"}
--&MESG "DDM Alarm appears on Booster input of PMOA-B in slot $2 ($A)"
DESCRIPTION "Urgent client default is activated"
::= { pmoabtraps 42 }
pmoabClientTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoabAlmClientDdmAlm, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Client Urgent OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAB Client Urgent ON"}
--&MATCH { pmoabAlmClientDdmAlm "on", pmoabtrapBoardNumber "$2"}
--&MESG "DDM Alarm disappears on Booster input of PMOA-B in slot $2 ($A)"
DESCRIPTION "Urgent client default disappeared"
::= { pmoabtraps 43 }
pmoabClientTrapCritGoesOn NOTIFICATION-TYPE
OBJECTS {pmoabAlmClientFail, pmoabAlmClientHwFail, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Client Fail ON"
--&ACTIONS { log, critical }
--&MATCH { pmoabAlmClientFail "on", pmoabAlmClientHwFail "*", pmoabtrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Booster input of PMOA-B in slot $3 ($A)"
--&FILTNAME "PMOAB Client HW Fail ON (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoabAlmClientFail "*", pmoabAlmClientHwFail "on", pmoabtrapBoardNumber "$3"}
--&MESG "Critical Alarm appears on Booster input of PMOA-B in slot $3 ($A)"
DESCRIPTION "Critical client default is activated"
::= { pmoabtraps 44 }
pmoabClientTrapCritGoesOff NOTIFICATION-TYPE
OBJECTS {pmoabAlmClientFail, pmoabAlmClientHwFail, pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Client Fail OFF"
--&ACTIONS { log, normal }
--&CLEARS {"PMOAB Client Fail ON"}
--&MATCH { pmoabAlmClientFail "on", pmoabAlmClientHwFail "*", pmoabtrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Booster input of PMOA-B in slot $3 ($A)"
--&FILTNAME "PMOAB Client HW Fail OFF (Hidden)"
--&ACTIONS { info }
--&MATCH { pmoabAlmClientFail "*", pmoabAlmClientHwFail "on", pmoabtrapBoardNumber "$3"}
--&MESG "Critical Alarm disappears on Booster input of PMOA-B in slot $3 ($A)"
DESCRIPTION "Critical client default disappeared"
::= { pmoabtraps 45 }
--- *****************************************************
--- HW TRAPS
--- *****************************************************
pmoabPowerTrapUrgentGoesOn NOTIFICATION-TYPE
OBJECTS {pmoabAlmDefFuseB, pmoabAlmDefFuseA , pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Fuse A Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmoabAlmDefFuseB "*", pmoabAlmDefFuseA "on", pmoabtrapBoardNumber "$3"}
--&MESG "Power Input A Fail on PMOA-B in Slot $3 ($A)"
--&FILTNAME "PMOAB Fuse B Fail ON"
--&ACTIONS { log, major }
--&MATCH { pmoabAlmDefFuseB "on", pmoabAlmDefFuseA "*", pmoabtrapBoardNumber "$3"}
--&MESG "Power Input B Fail on PMOA-B in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default is activated"
::= { pmoabtraps 50 }
pmoabPowerTrapUrgentGoesOff NOTIFICATION-TYPE
OBJECTS {pmoabAlmDefFuseB, pmoabAlmDefFuseA , pmoabtrapBoardNumber}
STATUS current
--&FILTNAME "PMOAB Fuse A&B Fail OFF"
--&ACTIONS { log, normal}
--&CLEARS { "PMOAB Fuse A Fail ON", "PMOAB Fuse B Fail ON" }
--&MATCH { pmoabAlmDefFuseB "on", pmoabAlmDefFuseA "on", pmoabtrapBoardNumber "$3"}
--&MESG "Power Inputs A and B Present on PMOA-B in Slot $3 ($A)"
DESCRIPTION "Urgent power supply default disappeared"
::= { pmoabtraps 51 }