Observium_CE/mibs/cisco/METRO1500-MIB

2482 lines
69 KiB
Plaintext

--
-- METRO1500-MIB.my: Metro1500 device-specific MIB
--
-- February 2000, Gabriel Lee
--
-- Copyright (c) 2000, 2001 by cisco Systems, Inc.
-- All rights reserved.
--
-- This mib is modified from fsp_II.mib
METRO1500-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB;
org OBJECT IDENTIFIER ::= { iso 3 }
dod OBJECT IDENTIFIER ::= { org 6 }
internet OBJECT IDENTIFIER ::= { dod 1 }
private OBJECT IDENTIFIER ::= { internet 4 }
enterprises OBJECT IDENTIFIER ::= { private 1 }
adva OBJECT IDENTIFIER ::= { enterprises 2544 }
advaProducts OBJECT IDENTIFIER ::= { adva 1 }
-----------------------------------------------------------
-----------------------------------------------------------
metro1500 OBJECT IDENTIFIER
-- LAST-UPDATED "200106120600Z"
-- ORGANIZATION "Cisco Systems, Inc."
-- CONTACT-INFO
-- "Cisco Systems
-- Customer Service
--
-- Postal: 170 W Tasman Drive
-- San Jose, CA 95134
-- USA
--
-- Tel: +1 800 553-NETS
--
-- E-mail: cs-snmp@cisco.com"
-- DESCRIPTION
-- "The MIB module for Cisco Metro 1500."
-- History:
-- 16.03.1999 Release 1.0
-- 30.03.1999 Release 2.0
-- Added Switch functionality
-- 09.06.1999 Release 3.0
-- Added Message of the Day
-- Added Trap Sink Table
-- Added Logfile Table
-- 15.06.1999 Release 3.1
-- Added Software control to Lasers
-- 04.08.1999 Release 3.11
-- Delete Commas at the End of declarations
-- 11.08.1999 Release 3.2
-- Added EPLD Software Version
-- 08.09.1999 Release 3.21
-- Delete Commas at the end of Enumeration
-- Add new Slot Type Numbers
-- Change Trap Sink Priority to 1..20
-- Change Range of EPLD Version to 0..255
-- 01.10.1999 Release 3.22
-- Change Comment of Clock Frequency from
-- MHz to Mbit/s (sorry)
-- 27.08.2000 Release 3.23
-- Change Name for NEMI Slave to DEMI
-- Change Name of Trap #50 from Buffer Overflow to
-- Repeated Message
-- 30.08.2000 Release 3.24
-- Add SlotTypes for TRL converter
-- 13.09.2000 Release 3.25
-- Add Traps for NEMI interconnection down and up
-- 14.09.2000 Release 3.26
-- Add Clock Types
-- 29.09.2000 Release 3.27
-- Change INC (inter NEMI connection) to
-- INNC (Inter NEMI network connection)
-- 04.11.2000 Release 3.28
-- Add Variables and Traps for TDM Cards and
-- Ethernet Hubs
-- 10.11.2000 Release 3.29
-- Add slot type for Ethernet Hubs and TDM Cards
-- 18.12.2000 Release 3.30
-- Add clock type 11
-- Change Limit of Slot Numbers to 1..79
-- 11.06.2001 Release 3.31
-- Changed TRAP-TYPE metro1500TDMLocModuleEnable1 to metro1500TDMLocModuleEnabled1,
-- metro1500TDMLocModuleEnable2 to metro1500TDMLocModuleEnabled2,
-- metro1500TDMLocModuleEnable3 to metro1500TDMLocModuleEnabled3,
-- metro1500TDMLocModuleEnable4 to metro1500TDMLocModuleEnabled4
::= { advaProducts 3 }
-----------------------------------------------------------
-----------------------------------------------------------
-----------------------------------------------------------
-- Main Tree defines the METRO1500 housing and the
-- installed Components
-----------------------------------------------------------
metro1500Main OBJECT IDENTIFIER ::= { metro1500 1 }
-----------------------------------------------------------
-- Starting with the Definition of the Device-Master
-----------------------------------------------------------
metro1500Housing OBJECT IDENTIFIER ::= { metro1500Main 1 }
metro1500Manufacturer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturer of the METRO1500 System"
::= { metro1500Housing 1 }
metro1500MainType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the METRO1500 System"
::= { metro1500Housing 2 }
metro1500MainSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial Number of the METRO1500 System"
::= { metro1500Housing 3 }
metro1500MainHardwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hardware Version of the METRO1500 System"
::= { metro1500Housing 4 }
metro1500MainSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Software Version of the METRO1500 System (Device Master)."
::= { metro1500Housing 5 }
metro1500MainBusMessages OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of received internal Messages. This Number gives
Information on the internal Activity of the METRO1500
System. This should be a large integer Number except when the
System has just started. The Value is updated every five
Seconds."
::= { metro1500Housing 6 }
metro1500MainBusErrors OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of dropped received internal Messages. This value
should be 0 or a very small Integer."
::= { metro1500Housing 7 }
-- Last Event will be implemented later
metro1500MainLastEvent OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Since SNMP Traps are not reliable, this Number can be polled
periodically. The Value is set to a nonzero Integer when an
Event occurs and cleared ten Minutes after the last Event."
::= { metro1500Housing 8 }
-- Display the Message Of the Day
metro1500MainMotd OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Message Of The Day is the greeting when login via telnet. It
shows the actual Kernel Version and the Software Update
State. With the MOTD you get Information on the actual
installed Software Packets."
::= { metro1500Housing 9 }
-- Define a Table with all used Trapsinks
metro1500MainTrapsinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500MainTrapsinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Trapsinks"
::= { metro1500Housing 10 }
metro1500MainTrapsinkEntry OBJECT-TYPE
SYNTAX Metro1500MainTrapsinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries in the Trapsink Table"
INDEX { metro1500MainTrapsinkNumber }
::= { metro1500MainTrapsinkTable 1 }
Metro1500MainTrapsinkEntry ::=
SEQUENCE {
metro1500MainTrapsinkNumber
INTEGER,
metro1500MainTrapsinkAddress
DisplayString,
metro1500MainTrapsinkCommunity
DisplayString,
metro1500MainTrapsinkPriority
INTEGER
}
metro1500MainTrapsinkNumber OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Trapsink"
::= { metro1500MainTrapsinkEntry 1 }
metro1500MainTrapsinkAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Address of the Management System which should receive SNMP
Traps. The Logfiles are also shown in this Table"
::= { metro1500MainTrapsinkEntry 2 }
metro1500MainTrapsinkCommunity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Community String which is sent with a SNMP Trap to the
Management Station"
::= { metro1500MainTrapsinkEntry 3 }
metro1500MainTrapsinkPriority OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Priority of the Trapsink (lower level gets less Traps)"
::= { metro1500MainTrapsinkEntry 4 }
-- Define a Table with all Log Files
metro1500MainLogfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500MainLogfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Log Files"
::= { metro1500Housing 11 }
metro1500MainLogfileEntry OBJECT-TYPE
SYNTAX Metro1500MainLogfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries in the Logfile Table"
INDEX { metro1500MainLogfileNumber }
::= { metro1500MainLogfileTable 1 }
Metro1500MainLogfileEntry ::=
SEQUENCE {
metro1500MainLogfileNumber
INTEGER,
metro1500MainLogfileName
DisplayString,
metro1500MainLogfileSize
INTEGER,
metro1500MainLogfilePriority
INTEGER
}
metro1500MainLogfileNumber OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Logfile"
::= { metro1500MainLogfileEntry 1 }
metro1500MainLogfileName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of Logfile"
::= { metro1500MainLogfileEntry 2 }
metro1500MainLogfileSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Size of Logfile"
::= { metro1500MainLogfileEntry 3 }
metro1500MainLogfilePriority OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Priority of Logfile"
::= { metro1500MainLogfileEntry 4 }
-----------------------------------------------------------
-- Definition of the Slot Table
-----------------------------------------------------------
metro1500SlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500SlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of installed METRO1500 Components. Since METRO1500 can
handle many different Components, in this Section only the
common Information is displayed. Component specific
Information is stored in different Subtrees."
::= { metro1500Main 2 }
metro1500SlotEntry OBJECT-TYPE
SYNTAX Metro1500SlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Installed METRO1500 Components"
INDEX { metro1500SlotNumber }
::= { metro1500SlotTable 1 }
Metro1500SlotEntry ::=
SEQUENCE {
metro1500SlotNumber
INTEGER,
metro1500Type
DisplayString,
metro1500SlotTypeNumber
INTEGER,
metro1500SerialNumber
DisplayString,
metro1500HardwareVersion
DisplayString,
metro1500SoftwareVersion
DisplayString,
metro1500Temperature
INTEGER,
metro1500BoardVoltage
INTEGER,
metro1500DetailInfo
OBJECT IDENTIFIER,
metro1500EPLDVersion
INTEGER
}
metro1500SlotNumber OBJECT-TYPE
SYNTAX INTEGER (1..79)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot Number of installed Component. The Device
Master has always Slot Number 0 and is shown in the
Main section."
::= { metro1500SlotEntry 1 }
metro1500Type OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of installed Component"
::= { metro1500SlotEntry 2 }
metro1500SlotTypeNumber OBJECT-TYPE
SYNTAX INTEGER
{
-- hotStandbyConverter (0),
metro1500Converter (1),
metro1000Converter (2),
metro1000EthernetConverter (3),
metro1500-2-5GbConverter (5),
metro1500-TRL-Converter (7),
metro1500-4PortTDMCard (10),
nemi (32),
demi (33),
metro1500-EthernetHubCard (39),
switch (64),
other (255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Integer Number between 0 and 255 unique for a
specific type of installed Component. This
Number can be used for management Systems to
handle automatically the different Options
of installed Components."
::= { metro1500SlotEntry 3 }
metro1500SerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial Number of installed Component"
::= { metro1500SlotEntry 4 }
metro1500HardwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hardware Version of installed Component"
::= { metro1500SlotEntry 5 }
metro1500SoftwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SoftwareVersion of installed Component"
::= { metro1500SlotEntry 6 }
metro1500Temperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature of installed Component in
Celsius"
::= { metro1500SlotEntry 7}
metro1500BoardVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Voltage measured directly on the board in mV"
::= { metro1500SlotEntry 8 }
metro1500DetailInfo OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A Reference to the MIB Definition where the special
Options of the Component are described with more Details"
::= { metro1500SlotEntry 9 }
metro1500EPLDVersion OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Software Version on the programmable Logic Circuit"
::= { metro1500SlotEntry 10 }
-----------------------------------------------------------
-- Table of installed Power Supplies
-----------------------------------------------------------
metro1500PSTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500PSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of installed Power Supplies"
::= {metro1500Main 3 }
metro1500PSEntry OBJECT-TYPE
SYNTAX Metro1500PSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Installed METRO1500 Power Supplies"
INDEX { metro1500PSNumber }
::= {metro1500PSTable 1 }
Metro1500PSEntry ::=
SEQUENCE
{
metro1500PSNumber
INTEGER,
metro1500PSOn
INTEGER
}
metro1500PSNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of installed Power Supply"
::= { metro1500PSEntry 1 }
metro1500PSOn OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is installed Power Supply On or Off"
::= { metro1500PSEntry 2 }
-----------------------------------------------------------
-- Table of installed Fans
-----------------------------------------------------------
metro1500FanTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500FanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of installed Fans"
::= { metro1500Main 4 }
metro1500FanEntry OBJECT-TYPE
SYNTAX Metro1500FanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Installed METRO1500 Fans"
INDEX { metro1500FanNumber }
::= { metro1500FanTable 1 }
Metro1500FanEntry ::=
SEQUENCE
{
metro1500FanNumber
INTEGER,
metro1500FanOn
INTEGER
}
metro1500FanNumber OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of installed Fan"
::= { metro1500FanEntry 1 }
metro1500FanOn OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is installed Fan On or Off"
::= { metro1500FanEntry 2 }
-----------------------------------------------------------
-- Description of installed Converter Cards
-----------------------------------------------------------
metro1500Converter OBJECT IDENTIFIER ::= { metro1500 5 }
metro1500ConverterTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500ConverterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of installed METRO1500 Converters"
::= { metro1500Converter 1 }
metro1500ConverterEntry OBJECT-TYPE
SYNTAX Metro1500ConverterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Installed METRO1500 Converters"
INDEX { metro1500ConverterNumber }
::= { metro1500ConverterTable 1 }
Metro1500ConverterEntry ::=
SEQUENCE
{
metro1500ConverterNumber
INTEGER,
metro1500RxLoc
INTEGER,
metro1500TxLoc
INTEGER,
metro1500TxLocC
INTEGER,
metro1500TxLocTemp
INTEGER,
metro1500RxRem
INTEGER,
metro1500TxRem
INTEGER,
metro1500TxRemC
INTEGER,
metro1500TxRemTemp
INTEGER,
metro1500RxRem2
INTEGER,
metro1500ClockState
INTEGER,
metro1500ClockFreq
INTEGER,
metro1500LocLoop
INTEGER,
metro1500RemLoop
INTEGER,
metro1500ClockType
INTEGER
}
metro1500ConverterNumber OBJECT-TYPE
SYNTAX INTEGER (1..79)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot Number of installed Converter Card"
::= { metro1500ConverterEntry 1 }
metro1500RxLoc OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local Receiver has Signal (On) or Loss
of Signal (Off)"
::= { metro1500ConverterEntry 2 }
metro1500TxLoc OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2),
alwaysOn (3),
alwaysOff (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local Transmitter is On or Off"
::= { metro1500ConverterEntry 3 }
metro1500TxLocC OBJECT-TYPE
SYNTAX INTEGER (0..200)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current of the local Transmitter in mA.
This Entry is only available if a Current Sensor is
installed"
::= { metro1500ConverterEntry 4 }
metro1500TxLocTemp OBJECT-TYPE
SYNTAX INTEGER (-50..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature of the local Transmitter in Celsius.
This Entry is only available if the Laser is cooled"
::= { metro1500ConverterEntry 5 }
metro1500RxRem OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Receiver has Signal (On) or Loss
of Signal (Off)"
::= { metro1500ConverterEntry 6 }
metro1500TxRem OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2),
alwaysOn (3),
alwaysOff (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Transmitter is On or Off"
::= { metro1500ConverterEntry 7 }
metro1500TxRemC OBJECT-TYPE
SYNTAX INTEGER (0..200)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current of the Remote Transmitter in Milli Ampere.
This Entry is only available if a Current Sensor is
installed"
::= { metro1500ConverterEntry 8 }
metro1500TxRemTemp OBJECT-TYPE
SYNTAX INTEGER (-50..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature of the Remote Transmitter in Celsius
This Entry is only available if the Laser is cooled"
::= { metro1500ConverterEntry 9 }
metro1500RxRem2 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"2nd Remote receiver has Signal (On) or Loss
of Signal (Off).
(Only available if a 2nd Remote Receiver is
installed)"
::= { metro1500ConverterEntry 10 }
metro1500ClockState OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2),
fail (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of the Clock. This Entry is only available
if a Clock is installed. If the Clock is enabled,
and has an error output, and cannot synchronize to
the Signal, the Clock fails."
::= { metro1500ConverterEntry 11 }
metro1500ClockFreq OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Frequency of the Clock in MBit/s. Only available if
a Clock is installed."
::= { metro1500ConverterEntry 12 }
metro1500LocLoop OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local Loop is set to On or to Off"
::= { metro1500ConverterEntry 13 }
metro1500RemLoop OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Loop is set to On or to Off"
::= { metro1500ConverterEntry 14 }
metro1500ClockType OBJECT-TYPE
SYNTAX INTEGER
{
-- Low speed Multi Clock
multiClockLSModule (1),
multiClockLS (2),
-- Multi Clock Fibre Channel / Gbit Ethernet
multiClockFCGbE (3),
-- Multi Clock OCx / Gbit Ethernet
multiClockOCxGbE (5),
-- Multi Clock OCx / Fibre Channel
multiClockOCxFC (7),
-- Multi Clock OCx / Gbit Ethernet / Fibre Channel
multiClockOCxGbEFC (9),
-- Multi Clock Fibre Channel / Gbit Ethernet on Board
multiClockFCGbEOnBoard (11),
-- fixed Clocks
fixedClock125MbpsModule (21),
fixedClock125Mbps (22),
fixedClock155MbpsModule (31),
fixedClock155Mbps (32),
fixedClock200MbpsModule (41),
fixedClock200Mbps (42),
fixedClock266MbpsModule (51),
fixedClock266Mbps (52),
fixedClock622MbpsModule (61),
fixedClock622Mbps (62),
fixedClock1062MbpsModule (71),
fixedClock1062Mbps (72),
fixedClock1250MbpsModule (75),
fixedClock1250Mbps (76),
fixedClock2500MbpsModule (81),
fixedClock2500Mbps (82),
other (255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the Clock. Only available, if a Clock is installed."
::= { metro1500ConverterEntry 15 }
-----------------------------------------------------------
-- Description of installed Switches
-- We start at #10 to leave some Space for different
-- Converters Cards
-----------------------------------------------------------
metro1500Switch OBJECT IDENTIFIER ::= { metro1500 10 }
metro1500SwitchTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500SwitchEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of installed METRO1500 Switches"
::= { metro1500Switch 1 }
metro1500SwitchEntry OBJECT-TYPE
SYNTAX Metro1500SwitchEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Installed METRO1500 Switches"
INDEX { metro1500SwitchNumber }
::= { metro1500SwitchTable 1 }
Metro1500SwitchEntry ::=
SEQUENCE
{
metro1500SwitchNumber
INTEGER,
metro1500SwitchLine
INTEGER,
metro1500SwitchMode
INTEGER,
metro1500SwitchLaserOn
INTEGER,
metro1500SwitchLineAavail
INTEGER,
metro1500SwitchLineBavail
INTEGER
}
metro1500SwitchNumber OBJECT-TYPE
SYNTAX INTEGER (1..79)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot Number of installed Remote Optical Switch Card"
::= { metro1500SwitchEntry 1 }
metro1500SwitchLine OBJECT-TYPE
SYNTAX INTEGER
{
lineA(1),
lineB(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active Line of Remote Optical Switch"
::= { metro1500SwitchEntry 2 }
metro1500SwitchMode OBJECT-TYPE
SYNTAX INTEGER
{
automatic(1),
locked(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mode of Transmit Line of Remote Optical Switch"
::= { metro1500SwitchEntry 3 }
metro1500SwitchLaserOn OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Shows if the reference Laser is On or Off"
::= { metro1500SwitchEntry 4 }
metro1500SwitchLineAavail OBJECT-TYPE
SYNTAX INTEGER
{
available(1),
notAvailable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is Line A of Remote Optical Switch available?"
::= { metro1500SwitchEntry 5 }
metro1500SwitchLineBavail OBJECT-TYPE
SYNTAX INTEGER
{
available(1),
notAvailable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is Line B of Remote Optical Switch available"
::= { metro1500SwitchEntry 6 }
-----------------------------------------------------------
-- Description of installed Ethernet Hub Cards
-----------------------------------------------------------
metro1500EthernetHub OBJECT IDENTIFIER ::= { metro1500 14 }
metro1500EthernetHubTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500EthernetHubEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of installed FSP-II Hub Cards"
::= { metro1500EthernetHub 1 }
metro1500EthernetHubEntry OBJECT-TYPE
SYNTAX Metro1500EthernetHubEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Installed FSP-II Hub Cards"
INDEX { metro1500EthernetHubNumber }
::= { metro1500EthernetHubTable 1 }
Metro1500EthernetHubEntry ::=
SEQUENCE
{
-- Slot number of Hub Card
metro1500EthernetHubNumber
INTEGER,
-- values for Port 1
metro1500EthernetHubPortEnable1
INTEGER,
metro1500EthernetHubPortPartitionStatus1
INTEGER,
metro1500EthernetHubPortLinkStatus1
INTEGER,
metro1500EthernetHubPortPolarity1
INTEGER,
-- values for Port 2
metro1500EthernetHubPortEnable2
INTEGER,
metro1500EthernetHubPortPartitionStatus2
INTEGER,
metro1500EthernetHubPortLinkStatus2
INTEGER,
metro1500EthernetHubPortPolarity2
INTEGER,
-- values for Port 3
metro1500EthernetHubPortEnable3
INTEGER,
metro1500EthernetHubPortPartitionStatus3
INTEGER,
metro1500EthernetHubPortLinkStatus3
INTEGER,
metro1500EthernetHubPortPolarity3
INTEGER,
-- values for Port 4
metro1500EthernetHubPortEnable4
INTEGER,
metro1500EthernetHubPortPartitionStatus4
INTEGER,
metro1500EthernetHubPortLinkStatus4
INTEGER,
metro1500EthernetHubPortPolarity4
INTEGER,
-- values for Port 5
metro1500EthernetHubPortEnable5
INTEGER,
metro1500EthernetHubPortPartitionStatus5
INTEGER,
metro1500EthernetHubPortLinkStatus5
INTEGER,
metro1500EthernetHubPortPolarity5
INTEGER
}
-- Slot Number of Hub Card
metro1500EthernetHubNumber OBJECT-TYPE
SYNTAX INTEGER (1..79)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot Number of installed Hub Card"
::= { metro1500EthernetHubEntry 1 }
-- values for Port 1
metro1500EthernetHubPortEnable1 OBJECT-TYPE
SYNTAX INTEGER
{
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Hub Port 1 enabled ?"
::= { metro1500EthernetHubEntry 10 }
metro1500EthernetHubPortPartitionStatus1 OBJECT-TYPE
SYNTAX INTEGER
{
partitioned (1),
notPartitioned (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Port 1 partitioned ?"
::= { metro1500EthernetHubEntry 11 }
metro1500EthernetHubPortLinkStatus1 OBJECT-TYPE
SYNTAX INTEGER
{
linked (1),
notLinked (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"does Port 1 receive Link Pulses ?"
::= { metro1500EthernetHubEntry 12 }
metro1500EthernetHubPortPolarity1 OBJECT-TYPE
SYNTAX INTEGER
{
positive (1),
negative (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"polarity of input signal at Port 1"
::= { metro1500EthernetHubEntry 13 }
-- values for Port 2
metro1500EthernetHubPortEnable2 OBJECT-TYPE
SYNTAX INTEGER
{
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Hub Port 2 enabled ?"
::= { metro1500EthernetHubEntry 20 }
metro1500EthernetHubPortPartitionStatus2 OBJECT-TYPE
SYNTAX INTEGER
{
partitioned (1),
notPartitioned (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Port 2 partitioned ?"
::= { metro1500EthernetHubEntry 21 }
metro1500EthernetHubPortLinkStatus2 OBJECT-TYPE
SYNTAX INTEGER
{
linked (1),
notLinked (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"does Port 2 receive Link Pulses ?"
::= { metro1500EthernetHubEntry 22 }
metro1500EthernetHubPortPolarity2 OBJECT-TYPE
SYNTAX INTEGER
{
positive (1),
negative (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"polarity of input signal at Port 2"
::= { metro1500EthernetHubEntry 23 }
-- values for Port 3
metro1500EthernetHubPortEnable3 OBJECT-TYPE
SYNTAX INTEGER
{
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Hub Port 3 enabled ?"
::= { metro1500EthernetHubEntry 30 }
metro1500EthernetHubPortPartitionStatus3 OBJECT-TYPE
SYNTAX INTEGER
{
partitioned (1),
notPartitioned (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Port 3 partitioned ?"
::= { metro1500EthernetHubEntry 31 }
metro1500EthernetHubPortLinkStatus3 OBJECT-TYPE
SYNTAX INTEGER
{
linked (1),
notLinked (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"does Port 3 receive Link Pulses ?"
::= { metro1500EthernetHubEntry 32 }
metro1500EthernetHubPortPolarity3 OBJECT-TYPE
SYNTAX INTEGER
{
positive (1),
negative (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"polarity of input signal at Port 3"
::= { metro1500EthernetHubEntry 33 }
-- values for Port 4
metro1500EthernetHubPortEnable4 OBJECT-TYPE
SYNTAX INTEGER
{
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Hub Port 4 enabled ?"
::= { metro1500EthernetHubEntry 40 }
metro1500EthernetHubPortPartitionStatus4 OBJECT-TYPE
SYNTAX INTEGER
{
partitioned (1),
notPartitioned (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Port 4 partitioned ?"
::= { metro1500EthernetHubEntry 41 }
metro1500EthernetHubPortLinkStatus4 OBJECT-TYPE
SYNTAX INTEGER
{
linked (1),
notLinked (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"does Port 4 receive Link Pulses ?"
::= { metro1500EthernetHubEntry 42 }
metro1500EthernetHubPortPolarity4 OBJECT-TYPE
SYNTAX INTEGER
{
positive (1),
negative (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"polarity of input signal at Port 4"
::= { metro1500EthernetHubEntry 43 }
-- values for Port 5
metro1500EthernetHubPortEnable5 OBJECT-TYPE
SYNTAX INTEGER
{
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Hub Port 5 enabled ?"
::= { metro1500EthernetHubEntry 50 }
metro1500EthernetHubPortPartitionStatus5 OBJECT-TYPE
SYNTAX INTEGER
{
partitioned (1),
notPartitioned (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is Port 5 partitioned ?"
::= { metro1500EthernetHubEntry 51 }
metro1500EthernetHubPortLinkStatus5 OBJECT-TYPE
SYNTAX INTEGER
{
linked (1),
notLinked (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"does Port 5 receive Link Pulses ?"
::= { metro1500EthernetHubEntry 52 }
metro1500EthernetHubPortPolarity5 OBJECT-TYPE
SYNTAX INTEGER
{
positive (1),
negative (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"polarity of input signal at Port 5"
::= { metro1500EthernetHubEntry 53 }
-----------------------------------------------------------
-- Description of installed TDM (Time Division Multiplex)
-- cards.
-- We start with #15
-----------------------------------------------------------
metro1500TDM OBJECT IDENTIFIER ::= { metro1500 15 }
metro1500TDMTable OBJECT-TYPE
SYNTAX SEQUENCE OF Metro1500TDMEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of installed FSP-II TDM Cards"
::= { metro1500TDM 1 }
metro1500TDMEntry OBJECT-TYPE
SYNTAX Metro1500TDMEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Installed FSP-II TDM Cards"
INDEX { metro1500TDMNumber }
::= { metro1500TDMTable 1 }
Metro1500TDMEntry ::=
SEQUENCE
{
-- Slot Number of the TDM Card
metro1500TDMNumber
INTEGER,
-- values for the remote side
metro1500TDMRxRem
INTEGER,
metro1500TDMRxSync
INTEGER,
metro1500TDMTxRem
INTEGER,
metro1500TDMTxRemC
INTEGER,
metro1500TDMTxRemTemp
INTEGER,
-- common values
metro1500TDMLocLoop
INTEGER,
-- local module 1
metro1500TDMLocModuleInst1
INTEGER,
metro1500TDMLocModuleEnable1
INTEGER,
metro1500TDMLocModuleRx1
INTEGER,
metro1500TDMLocModuleTx1
INTEGER,
metro1500TDMLocModuleRemoteData1
INTEGER,
metro1500TDMLocModuleClockFrequency1
INTEGER,
metro1500TDMLocModuleClockError1
INTEGER,
-- local module 2
metro1500TDMLocModuleInst2
INTEGER,
metro1500TDMLocModuleEnable2
INTEGER,
metro1500TDMLocModuleRx2
INTEGER,
metro1500TDMLocModuleTx2
INTEGER,
metro1500TDMLocModuleRemoteData2
INTEGER,
metro1500TDMLocModuleClockFrequency2
INTEGER,
metro1500TDMLocModuleClockError2
INTEGER,
-- local module 3
metro1500TDMLocModuleInst3
INTEGER,
metro1500TDMLocModuleEnable3
INTEGER,
metro1500TDMLocModuleRx3
INTEGER,
metro1500TDMLocModuleTx3
INTEGER,
metro1500TDMLocModuleRemoteData3
INTEGER,
metro1500TDMLocModuleClockFrequency3
INTEGER,
metro1500TDMLocModuleClockError3
INTEGER,
-- local module 4
metro1500TDMLocModuleInst4
INTEGER,
metro1500TDMLocModuleEnable4
INTEGER,
metro1500TDMLocModuleRx4
INTEGER,
metro1500TDMLocModuleTx4
INTEGER,
metro1500TDMLocModuleRemoteData4
INTEGER,
metro1500TDMLocModuleClockFrequency4
INTEGER,
metro1500TDMLocModuleClockError4
INTEGER
}
-- Slot number of the TDM Card
metro1500TDMNumber OBJECT-TYPE
SYNTAX INTEGER (1..79)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot Number of installed TDM Card"
::= { metro1500TDMEntry 1 }
-- Values for the remote side
metro1500TDMRxRem OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Does the remote receiver receive Light (on) or not
(off)?"
::= { metro1500TDMEntry 4 }
metro1500TDMRxSync OBJECT-TYPE
SYNTAX INTEGER
{
sync (1),
noSync (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is the input signal synchronized with the corresponding
TDM card?"
::= { metro1500TDMEntry 5 }
metro1500TDMTxRem OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2),
alwaysOn (3),
alwaysOff (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of the Remote Transmitter"
::= { metro1500TDMEntry 6 }
metro1500TDMTxRemC OBJECT-TYPE
SYNTAX INTEGER (0..200)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current of the remote Transmitter in mA"
::= { metro1500TDMEntry 7 }
metro1500TDMTxRemTemp OBJECT-TYPE
SYNTAX INTEGER (-50..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature of the remote Transmitter in Celsius"
::= { metro1500TDMEntry 8 }
-- common values
metro1500TDMLocLoop OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Loop for all Local Inputs enabled (on) or disabled (off)"
::= { metro1500TDMEntry 9 }
-- values for local module 1
metro1500TDMLocModuleInst1 OBJECT-TYPE
SYNTAX INTEGER
{
installed (1),
notInstalled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is local Module 1 installed ?"
::= { metro1500TDMEntry 20 }
metro1500TDMLocModuleEnable1 OBJECT-TYPE
SYNTAX INTEGER
{
enabled (1),
notEnabled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is local Module 1 enabled ?"
::= { metro1500TDMEntry 21 }
metro1500TDMLocModuleRx1 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"local receiver 1 gets signal (on)"
::= { metro1500TDMEntry 22 }
metro1500TDMLocModuleTx1 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2),
alwaysOn (3),
alwaysOff (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"state of the local transmitter"
::= { metro1500TDMEntry 23 }
metro1500TDMLocModuleRemoteData1 OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
noData (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"receiving data for this module from the remote side"
::= { metro1500TDMEntry 24 }
metro1500TDMLocModuleClockFrequency1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"data rate of the clock installed on local Module 1
in MBit/s"
::= { metro1500TDMEntry 25 }
metro1500TDMLocModuleClockError1 OBJECT-TYPE
SYNTAX INTEGER
{
error (1),
noError (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"data rate and clock frequency are not synchronized"
::= { metro1500TDMEntry 26 }
-- values for local module 2
metro1500TDMLocModuleInst2 OBJECT-TYPE
SYNTAX INTEGER
{
installed (1),
notInstalled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is local Module 2 installed ?"
::= { metro1500TDMEntry 30 }
metro1500TDMLocModuleEnable2 OBJECT-TYPE
SYNTAX INTEGER
{
enabled (1),
notEnabled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is local Module 2 enabled ?"
::= { metro1500TDMEntry 31 }
metro1500TDMLocModuleRx2 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"local receiver 2 gets signal (on)"
::= { metro1500TDMEntry 32 }
metro1500TDMLocModuleTx2 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2),
alwaysOn (3),
alwaysOff (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"state of the local transmitter"
::= { metro1500TDMEntry 33 }
metro1500TDMLocModuleRemoteData2 OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
noData (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"receiving data for this module from the remote side"
::= { metro1500TDMEntry 34 }
metro1500TDMLocModuleClockFrequency2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"data rate of the clock installed on local Module 2
in MBit/s"
::= { metro1500TDMEntry 35 }
metro1500TDMLocModuleClockError2 OBJECT-TYPE
SYNTAX INTEGER
{
error (1),
noError (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"data rate and clock frequency are not synchronized"
::= { metro1500TDMEntry 36 }
-- values for local module 3
metro1500TDMLocModuleInst3 OBJECT-TYPE
SYNTAX INTEGER
{
installed (1),
notInstalled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is local Module 3 installed ?"
::= { metro1500TDMEntry 40 }
metro1500TDMLocModuleEnable3 OBJECT-TYPE
SYNTAX INTEGER
{
enabled (1),
notEnabled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is local Module 3 enabled ?"
::= { metro1500TDMEntry 41 }
metro1500TDMLocModuleRx3 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"local receiver 3 gets signal (on)"
::= { metro1500TDMEntry 42 }
metro1500TDMLocModuleTx3 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2),
alwaysOn (3),
alwaysOff (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"state of the local transmitter"
::= { metro1500TDMEntry 43 }
metro1500TDMLocModuleRemoteData3 OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
noData (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"receiving data for this module from the remote side"
::= { metro1500TDMEntry 44 }
metro1500TDMLocModuleClockFrequency3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"data rate of the clock installed on local Module 3
in MBit/s"
::= { metro1500TDMEntry 45 }
metro1500TDMLocModuleClockError3 OBJECT-TYPE
SYNTAX INTEGER
{
error (1),
noError (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"data rate and clock frequency are not synchronized"
::= { metro1500TDMEntry 46 }
-- values for local module 4
metro1500TDMLocModuleInst4 OBJECT-TYPE
SYNTAX INTEGER
{
installed (1),
notInstalled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is local Module 4 installed ?"
::= { metro1500TDMEntry 50 }
metro1500TDMLocModuleEnable4 OBJECT-TYPE
SYNTAX INTEGER
{
enabled (1),
notEnabled (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"is local Module 4 enabled ?"
::= { metro1500TDMEntry 51 }
metro1500TDMLocModuleRx4 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"local receiver 4 gets signal (on)"
::= { metro1500TDMEntry 52 }
metro1500TDMLocModuleTx4 OBJECT-TYPE
SYNTAX INTEGER
{
on (1),
off (2),
alwaysOn (3),
alwaysOff (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"state of the local transmitter"
::= { metro1500TDMEntry 53 }
metro1500TDMLocModuleRemoteData4 OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
noData (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"receiving data for this module from the remote side"
::= { metro1500TDMEntry 54 }
metro1500TDMLocModuleClockFrequency4 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"data rate of the clock installed on local Module 4
in MBit/s"
::= { metro1500TDMEntry 55 }
metro1500TDMLocModuleClockError4 OBJECT-TYPE
SYNTAX INTEGER
{
error (1),
noError (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"data rate and clock frequency are not synchronized"
::= { metro1500TDMEntry 56 }
-----------------------------------------------------------
-- The List of all Events which may occur during
-- operation
-- The List is added at 100 in the MIB Tree list to
-- leave a lot of space for many installed
-- components.
-----------------------------------------------------------
metro1500Trap OBJECT IDENTIFIER ::= { metro1500 100}
-----------------------------------------------------------
-- Traps which are generated by the Main System
-- (Housing, Power Supplies, Fans, internal Bus ...)
-----------------------------------------------------------
metro1500HardwareAdded TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when a new Module is inserted
into the FSP-I Box"
::= 1
metro1500HardwareDeleted TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when a Module is removed
from the FSP-I Box"
::= 2
metro1500PSNotFail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500PSNumber }
DESCRIPTION
"Trap is sent when a Power Supply
starts working"
::= 3
metro1500PSFail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500PSNumber }
DESCRIPTION
"Trap is sent when a Power Supply fails"
::= 4
metro1500FanNotFail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500FanNumber }
DESCRIPTION
"Trap is sent when a Fan starts working"
::= 5
metro1500FanFail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500FanNumber }
DESCRIPTION
"Trap is sent when a Fan fails"
::= 6
metro1500BusNotFail TRAP-TYPE
ENTERPRISE metro1500Trap
DESCRIPTION
"Trap is sent when the internal Bus starts
working again"
::= 7
metro1500BusFail TRAP-TYPE
ENTERPRISE metro1500Trap
DESCRIPTION
"Trap is sent when an internal Bus Failure occurs"
::= 8
-----------------------------------------------------------
-- Traps which are generated by the Converter Boards
-- start with #20
-----------------------------------------------------------
metro1500RxLocOn TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the local Receiver gets Signal"
::= 20
metro1500RxLocOff TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the local Receiver has Loss of Signal"
::= 21
metro1500TxLocOn TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the local Transmitter is switched on,
Either this trap or Trap #20 should be disabled in the
Configuration because they are typically sent at the same Time."
::= 22
metro1500TxLocOff TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the local Transmitter is switched off,
Either this trap or Trap #21 should be disabled in the
Configuration because they are typically sent at the same Time."
::= 23
metro1500RxRemOn TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the remote Receiver gets Signal"
::= 24
metro1500RxRemOff TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the remote Receiver has Loss of Signal"
::= 25
metro1500TxRemOn TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the remote Transmitter is switched on,
Either this trap or Trap #24 should be disabled in the
Configuration because they are typically sent at the same Time."
::= 26
metro1500TxRemOff TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the remote Transmitter is switched off,
Either this trap or Trap #25 should be disabled in the
Configuration because they are typically sent at the same Time."
::= 27
metro1500RxRem2On TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the 2nd remote Receiver gets Signal.
This Trap is only sent if there is a 2nd remote Receiver."
::= 28
metro1500RxRem2Off TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the 2nd remote Receiver has Loss of Signal.
This Trap is only sent if there is a 2nd remote Receiver."
::= 29
metro1500TxRem2On TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the 2nd remote Transmitter is switched on,
Either this Trap or Trap #28 should be disabled in the
Configuration because they are typically sent at the same Time.
This Trap is only sent if there is a 2nd remote Receiver."
::= 30
metro1500TxRem2Off TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the 2nd remote Transmitter is switched off,
Either this trap or Trap #29 should be disabled in the
Configuration because they are typically sent at the same Time."
::= 31
metro1500ClockNoFail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent if a Clock is installed and can
synchronize with the input Signal. This Trap is not sent
if the installed Clock does not have an error Output"
::= 32
metro1500ClockFail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent if a Clock is installed and can not
synchronize with the input Signal. This trap is not sent
if the installed Clock does not have an error Output"
::= 33
metro1500ClockChangeFrequency TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent if a multi frequency Clock is installed and
changes its frequency."
::= 34
metro1500LocLoopOn TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent if Local Loop is set to On."
::= 35
metro1500LocLoopOff TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent if Local Loop is set to Off."
::= 36
metro1500RemLoopOn TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent if Remote Loop is set to On."
::= 37
metro1500RemLoopOff TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent if Remote Loop is set to Off."
::= 38
-----------------------------------------------------------
-- Traps which are generated by the Remote Optical Switch
-- They start at #40 to leave Space for other Traps
-- Traps for the Remote Optical Switch are only sent, if
-- one switch is installed
-----------------------------------------------------------
metro1500switchReferenceLaserOn TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Reference Laser is switched on"
::= 40
metro1500switchReferenceLaserOff TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Reference Laser is switched off"
::= 41
metro1500switchToA TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Switch switches to Line A"
::= 42
metro1500switchToB TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Switch switches to Line B"
::= 43
metro1500switchAutomatic TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Switch is going to Automatic State"
::= 44
metro1500switchLocked TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Switch is going to Locked State"
::= 45
metro1500switchLineAavail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Switch Line A is available"
::= 46
metro1500switchLineANotAvail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Switch Line A is not available"
::= 47
metro1500switchLineBavail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Switch Line B is available"
::= 48
metro1500switchLineBNotAvail TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent when the Switch Line B is not available"
::= 49
metro1500repeatedMessage TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES {metro1500SlotNumber}
DESCRIPTION
"Trap is sent, after three times the same trap is sent (instead of
the fourth one). The original trap is suppressed for one minute."
::= 50
-----------------------------------------------------------
-- Traps for the NEMI Netcork Connection
-----------------------------------------------------------
metro1500INNCDown TRAP-TYPE
ENTERPRISE metro1500Trap
DESCRIPTION
"Trap is sent, when the Inter NEMI Network Connection (INNC) is down."
::= 51
metro1500INNCUp TRAP-TYPE
ENTERPRISE metro1500Trap
DESCRIPTION
"Trap is sent, when the Inter NEMI Network Connection (INNC) is up."
::= 52
-----------------------------------------------------------
-- Traps for the Ethernet Hub Card
-- (starting with #60)
-----------------------------------------------------------
metro1500EthernetHubPortEnable TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when one of the ports of the Ethernet Hub is
enabled by the management software (default). Use SNMP Get
to get the Port Number."
::= 60
metro1500EthernetHubPortDisable TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when one of the ports of the Ethernet Hub is
disabled by the management Software. Use SNMP Get to get
the Port number."
::= 61
metro1500EthernetHubPortPartitioned TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when a Hub Port is disabled by the Hub Hardware.
Use SNMP Get to get the Port Number."
::= 62
metro1500EthernetHubPortNotPartitioned TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when a Hub Port is enabled by the Hub Hardware
(default). Use SNMP Get to get the Port Number."
::= 63
metro1500EthernetHubPortLinkPulses TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when a Hub Port starts receiving Link Pulses.
Use SNMP Get to get the Port Number"
::= 64
metro1500EthernetHubPortNoLinkPulses TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when a Hub Port stops receiving Link Pulses.
Use SNMP Get to get the Port Number"
::= 65
-----------------------------------------------------------
-- Traps for the TDM Card
-- (we start with #70)
-----------------------------------------------------------
-- the remote side
metro1500TDMRemoteSyncLoss TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the synchronisation of the incoming
remote data stream is lost"
::= 70
metro1500TDMRemoteSync TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the synchronisation of the incoming
remote data stream is established"
::= 71
-- module enable / disable for every port
metro1500TDMLocModuleEnabled1 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when local module 1 is enabled by software"
::= 72
metro1500TDMLocModuleDisable1 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when local module 1 is disabled by software"
::= 73
metro1500TDMLocModuleEnabled2 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when local module 2 is enabled by software"
::= 74
metro1500TDMLocModuleDisable2 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when local module 2 is disabled by software"
::= 75
metro1500TDMLocModuleEnabled3 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when local module 3 is enabled by software"
::= 76
metro1500TDMLocModuleDisable3 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when local module 3 is disabled by software"
::= 77
metro1500TDMLocModuleEnabled4 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when local module 4 is enabled by software"
::= 78
metro1500TDMLocModuleDisable4 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when local module 4 is disabled by software"
::= 79
-- leave space for 8 channel TDM ...
-- local receive for every port
metro1500TDMLocModuleRxOn1 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the local receiver 1 of a TDM card gets
modulated signal"
::= 88
metro1500TDMLocModuleRxOff1 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the local receiver 1 of a TDM card doesn't
get modulated signal"
::= 89
metro1500TDMLocModuleRxOn2 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the local receiver 2 of a TDM card gets
modulated signal"
::= 90
metro1500TDMLocModuleRxOff2 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the local receiver 2 of a TDM card doesn't
get modulated signal"
::= 91
metro1500TDMLocModuleRxOn3 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the local receiver 3 of a TDM card gets
modulated signal"
::= 92
metro1500TDMLocModuleRxOff3 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the local receiver 3 of a TDM card doesn't
get modulated signal"
::= 93
metro1500TDMLocModuleRxOn4 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the local receiver 4 of a TDM card gets
modulated signal"
::= 94
metro1500TDMLocModuleRxOff4 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the local receiver 4 of a TDM card doesn't
get modulated signal"
::= 95
-- leave space for 8 channel TDM ...
-- data from the remote side for every local channel
metro1500TDMLocModuleData1 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when data from the remote side is available for
this TDM channel"
::= 104
metro1500TDMLocModuleNoData1 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when no data from the remote side is available for
this TDM channel"
::= 105
metro1500TDMLocModuleData2 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when data from the remote side is available for
this TDM channel"
::= 106
metro1500TDMLocModuleNoData2 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when no data from the remote side is available for
this TDM channel"
::= 107
metro1500TDMLocModuleData3 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when data from the remote side is available for
this TDM channel"
::= 108
metro1500TDMLocModuleNoData3 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when no data from the remote side is available for
this TDM channel"
::= 109
metro1500TDMLocModuleData4 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when data from the remote side is available for
this TDM channel"
::= 110
metro1500TDMLocModuleNoData4 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when no data from the remote side is available for
this TDM channel"
::= 111
-- leave space for 8 channel TDM
-- failures of the local clocks
metro1500TDMLocModuleClockFail1 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the Data Rate of the local input signal doesn't
match the Data Rate of the local clock"
::= 120
metro1500TDMLocModuleClockNoFail1 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the Data Rate of the local input signal matches
the Data Rate of the local clock"
::= 121
metro1500TDMLocModuleClockFail2 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the Data Rate of the local input signal doesn't
match the Data Rate of the local clock"
::= 122
metro1500TDMLocModuleClockNoFail2 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the Data Rate of the local input signal matches
the Data Rate of the local clock"
::= 123
metro1500TDMLocModuleClockFail3 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the Data Rate of the local input signal doesn't
match the Data Rate of the local clock"
::= 124
metro1500TDMLocModuleClockNoFail3 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the Data Rate of the local input signal matches
the Data Rate of the local clock"
::= 125
metro1500TDMLocModuleClockFail4 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the Data Rate of the local input signal doesn't
match the Data Rate of the local clock"
::= 126
metro1500TDMLocModuleClockNoFail4 TRAP-TYPE
ENTERPRISE metro1500Trap
VARIABLES { metro1500SlotNumber }
DESCRIPTION
"Trap is sent, when the Data Rate of the local input signal matches
the Data Rate of the local clock"
::= 127
END