741 lines
26 KiB
Plaintext
741 lines
26 KiB
Plaintext
-- *****************************************************************
|
|
-- SYNCE-MIB: ME1200 Private MIB
|
|
--
|
|
-- ****************************************************************
|
|
|
|
ME1200-SYNCE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
me1200SwitchMgmt
|
|
FROM CISCOME1200-MIB
|
|
ME1200InterfaceIndex FROM ME1200-TC
|
|
ME1200Unsigned8 FROM ME1200-TC
|
|
Integer32 FROM SNMPv2-SMI
|
|
Unsigned32 FROM SNMPv2-SMI
|
|
TruthValue FROM SNMPv2-TC
|
|
;
|
|
|
|
me1200SynceMib MODULE-IDENTITY
|
|
LAST-UPDATED "201605090000Z"
|
|
ORGANIZATION
|
|
"Cisco Systems, Inc"
|
|
CONTACT-INFO
|
|
"Cisco Systems, Inc
|
|
Customer Service
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
Tel: +1 800 553-NETS
|
|
E-mail: cs-me1200@cisco.com"
|
|
DESCRIPTION
|
|
"Private SyncE MIB."
|
|
REVISION "201605090000Z"
|
|
DESCRIPTION
|
|
"Added SyncE clock selector state change notification"
|
|
REVISION "201406240000Z"
|
|
DESCRIPTION
|
|
"Initial version"
|
|
::= { me1200SwitchMgmt 42 }
|
|
|
|
|
|
ME1200synceAnegMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { none(0), preferedSlave(1), preferedMaster(2), forcedSlave(3) }
|
|
|
|
ME1200synceEecOption ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { eecOption1(0), eecOption2(1) }
|
|
|
|
ME1200synceFrequency ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { disabled(0), freq1544kHz(1), freq2048kHz(2), freq10MHz(3), freqMax(4) }
|
|
|
|
ME1200syncePtsfState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { none(0), unusable(1), lossSync(2), lossAnnounce(3) }
|
|
|
|
ME1200synceQualityLevel ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { qlNone(0), qlPrc(1), qlSsua(2), qlSsub(3), qlEec2(4), qlEec1(5), qlDnu(6), qlInv(7), qlFail(8), qlLink(9) }
|
|
|
|
ME1200synceSelectionMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { manual(0), manualToSelected(1), autoNonrevertive(2), autoRevertive(3), forcedHoldover(4), forcedFreeRun(5) }
|
|
|
|
ME1200synceSelectorState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
SYNTAX INTEGER { locked(0), holdover(1), freerun(2), ptp(3), refFailed(4), acquiring(5) }
|
|
|
|
me1200SynceMibObjects OBJECT IDENTIFIER
|
|
::= { me1200SynceMib 1 }
|
|
|
|
me1200SynceCapabilities OBJECT IDENTIFIER
|
|
::= { me1200SynceMibObjects 1 }
|
|
|
|
me1200SynceCapabilitiesGlobal OBJECT IDENTIFIER
|
|
::= { me1200SynceCapabilities 1 }
|
|
|
|
me1200SynceCapabilitiesGlobalSourceCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of SyncE sources supported by the device."
|
|
::= { me1200SynceCapabilitiesGlobal 1 }
|
|
|
|
me1200SynceConfig OBJECT IDENTIFIER
|
|
::= { me1200SynceMibObjects 2 }
|
|
|
|
me1200SynceConfigGlobal OBJECT IDENTIFIER
|
|
::= { me1200SynceConfig 1 }
|
|
|
|
me1200SynceConfigGlobalClockSelectionMode OBJECT IDENTIFIER
|
|
::= { me1200SynceConfigGlobal 1 }
|
|
|
|
me1200SynceConfigGlobalClockSelectionModeSelectionMode OBJECT-TYPE
|
|
SYNTAX ME1200synceSelectionMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The selection mode."
|
|
::= { me1200SynceConfigGlobalClockSelectionMode 1 }
|
|
|
|
me1200SynceConfigGlobalClockSelectionModeSource OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Nominated source for manuel selection mode."
|
|
::= { me1200SynceConfigGlobalClockSelectionMode 2 }
|
|
|
|
me1200SynceConfigGlobalClockSelectionModeWtrTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"WTR timer value in minutes. Range is 0 to 12 minutes where 0 means that
|
|
the timer is disabled."
|
|
::= { me1200SynceConfigGlobalClockSelectionMode 3 }
|
|
|
|
me1200SynceConfigGlobalClockSelectionModeSsmHoldover OBJECT-TYPE
|
|
SYNTAX ME1200synceQualityLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tx overwrite SSM used when clock controller is hold over."
|
|
::= { me1200SynceConfigGlobalClockSelectionMode 4 }
|
|
|
|
me1200SynceConfigGlobalClockSelectionModeSsmFreerun OBJECT-TYPE
|
|
SYNTAX ME1200synceQualityLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tx overwrite SSM used when clock controller is free run."
|
|
::= { me1200SynceConfigGlobalClockSelectionMode 5 }
|
|
|
|
me1200SynceConfigGlobalClockSelectionModeEecOption OBJECT-TYPE
|
|
SYNTAX ME1200synceEecOption
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synchronous Ethernet Equipment Clock option."
|
|
::= { me1200SynceConfigGlobalClockSelectionMode 6 }
|
|
|
|
me1200SynceConfigGlobalStationClocks OBJECT IDENTIFIER
|
|
::= { me1200SynceConfigGlobal 2 }
|
|
|
|
me1200SynceConfigGlobalStationClocksStationClkOut OBJECT-TYPE
|
|
SYNTAX ME1200synceFrequency
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Station clock output frequency setting."
|
|
::= { me1200SynceConfigGlobalStationClocks 1 }
|
|
|
|
me1200SynceConfigGlobalStationClocksStationClkIn OBJECT-TYPE
|
|
SYNTAX ME1200synceFrequency
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Station clock input frequency setting."
|
|
::= { me1200SynceConfigGlobalStationClocks 2 }
|
|
|
|
me1200SynceConfigSources OBJECT IDENTIFIER
|
|
::= { me1200SynceConfig 2 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200SynceConfigSourcesClockSourceNominationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the SyncE source nomination configuration."
|
|
::= { me1200SynceConfigSources 1 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationEntry OBJECT-TYPE
|
|
SYNTAX ME1200SynceConfigSourcesClockSourceNominationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sourceId index must be a value from 0 up to the number of sources
|
|
minus one."
|
|
INDEX { me1200SynceConfigSourcesClockSourceNominationSourceId }
|
|
::= { me1200SynceConfigSourcesClockSourceNominationTable 1 }
|
|
|
|
ME1200SynceConfigSourcesClockSourceNominationEntry ::= SEQUENCE {
|
|
me1200SynceConfigSourcesClockSourceNominationSourceId Integer32,
|
|
me1200SynceConfigSourcesClockSourceNominationNominated TruthValue,
|
|
me1200SynceConfigSourcesClockSourceNominationNetworkPort ME1200InterfaceIndex,
|
|
me1200SynceConfigSourcesClockSourceNominationClkInPort ME1200Unsigned8,
|
|
me1200SynceConfigSourcesClockSourceNominationPriority Unsigned32,
|
|
me1200SynceConfigSourcesClockSourceNominationAnegMode ME1200synceAnegMode,
|
|
me1200SynceConfigSourcesClockSourceNominationSsmOverwrite ME1200synceQualityLevel,
|
|
me1200SynceConfigSourcesClockSourceNominationHoldoffTime Unsigned32
|
|
}
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationSourceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200SynceConfigSourcesClockSourceNominationEntry 1 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationNominated OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if source is nominated."
|
|
::= { me1200SynceConfigSourcesClockSourceNominationEntry 2 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationNetworkPort OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface index of the norminated source."
|
|
::= { me1200SynceConfigSourcesClockSourceNominationEntry 3 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationClkInPort OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock input of the norminated source."
|
|
::= { me1200SynceConfigSourcesClockSourceNominationEntry 4 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Priority of the nominated source."
|
|
::= { me1200SynceConfigSourcesClockSourceNominationEntry 5 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationAnegMode OBJECT-TYPE
|
|
SYNTAX ME1200synceAnegMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Autonogotiation mode auto-master-slave."
|
|
::= { me1200SynceConfigSourcesClockSourceNominationEntry 6 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationSsmOverwrite OBJECT-TYPE
|
|
SYNTAX ME1200synceQualityLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SSM overwrite quality."
|
|
::= { me1200SynceConfigSourcesClockSourceNominationEntry 7 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationHoldoffTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hold Off timer value in 100ms (3 - 18). Zero means no hold off."
|
|
::= { me1200SynceConfigSourcesClockSourceNominationEntry 8 }
|
|
|
|
me1200SynceConfigPorts OBJECT IDENTIFIER
|
|
::= { me1200SynceConfig 3 }
|
|
|
|
me1200SynceConfigPortsPortConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200SynceConfigPortsPortConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the SyncE port configuration."
|
|
::= { me1200SynceConfigPorts 1 }
|
|
|
|
me1200SynceConfigPortsPortConfigEntry OBJECT-TYPE
|
|
SYNTAX ME1200SynceConfigPortsPortConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The portId index must be a value from 0 up to the number of ports minus
|
|
one."
|
|
INDEX { me1200SynceConfigPortsPortConfigPortId }
|
|
::= { me1200SynceConfigPortsPortConfigTable 1 }
|
|
|
|
ME1200SynceConfigPortsPortConfigEntry ::= SEQUENCE {
|
|
me1200SynceConfigPortsPortConfigPortId ME1200InterfaceIndex,
|
|
me1200SynceConfigPortsPortConfigSsmEnabled TruthValue
|
|
}
|
|
|
|
me1200SynceConfigPortsPortConfigPortId OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200SynceConfigPortsPortConfigEntry 1 }
|
|
|
|
me1200SynceConfigPortsPortConfigSsmEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Quality level via SSM enabled."
|
|
::= { me1200SynceConfigPortsPortConfigEntry 2 }
|
|
|
|
me1200SynceStatus OBJECT IDENTIFIER
|
|
::= { me1200SynceMibObjects 3 }
|
|
|
|
me1200SynceStatusGlobal OBJECT IDENTIFIER
|
|
::= { me1200SynceStatus 1 }
|
|
|
|
me1200SynceStatusGlobalClockSelectionMode OBJECT IDENTIFIER
|
|
::= { me1200SynceStatusGlobal 1 }
|
|
|
|
me1200SynceStatusGlobalClockSelectionModeClockInput OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock source locked to when clock selector is in locked state."
|
|
::= { me1200SynceStatusGlobalClockSelectionMode 1 }
|
|
|
|
me1200SynceStatusGlobalClockSelectionModeSelectorState OBJECT-TYPE
|
|
SYNTAX ME1200synceSelectorState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is indicating the state of the clock selector."
|
|
::= { me1200SynceStatusGlobalClockSelectionMode 2 }
|
|
|
|
me1200SynceStatusGlobalClockSelectionModeLosx OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LOSX"
|
|
::= { me1200SynceStatusGlobalClockSelectionMode 3 }
|
|
|
|
me1200SynceStatusGlobalClockSelectionModeLol OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock selector has raised the Los Of Lock alarm."
|
|
::= { me1200SynceStatusGlobalClockSelectionMode 4 }
|
|
|
|
me1200SynceStatusGlobalClockSelectionModeDhold OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock selector has not yet calculated the holdover frequency offset to
|
|
local oscillator."
|
|
::= { me1200SynceStatusGlobalClockSelectionMode 5 }
|
|
|
|
me1200SynceStatusSources OBJECT IDENTIFIER
|
|
::= { me1200SynceStatus 2 }
|
|
|
|
me1200SynceStatusSourcesClockSourceNominationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200SynceStatusSourcesClockSourceNominationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock source nomination status."
|
|
::= { me1200SynceStatusSources 1 }
|
|
|
|
me1200SynceStatusSourcesClockSourceNominationEntry OBJECT-TYPE
|
|
SYNTAX ME1200SynceStatusSourcesClockSourceNominationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sourceId index must be a value must be a value from 0 up to the
|
|
number of sources minus one."
|
|
INDEX { me1200SynceStatusSourcesClockSourceNominationSourceId }
|
|
::= { me1200SynceStatusSourcesClockSourceNominationTable 1 }
|
|
|
|
ME1200SynceStatusSourcesClockSourceNominationEntry ::= SEQUENCE {
|
|
me1200SynceStatusSourcesClockSourceNominationSourceId Integer32,
|
|
me1200SynceStatusSourcesClockSourceNominationLocs TruthValue,
|
|
me1200SynceStatusSourcesClockSourceNominationFos TruthValue,
|
|
me1200SynceStatusSourcesClockSourceNominationSsm TruthValue,
|
|
me1200SynceStatusSourcesClockSourceNominationWtr TruthValue
|
|
}
|
|
|
|
me1200SynceStatusSourcesClockSourceNominationSourceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200SynceStatusSourcesClockSourceNominationEntry 1 }
|
|
|
|
me1200SynceStatusSourcesClockSourceNominationLocs OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LOCS"
|
|
::= { me1200SynceStatusSourcesClockSourceNominationEntry 2 }
|
|
|
|
me1200SynceStatusSourcesClockSourceNominationFos OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FOS"
|
|
::= { me1200SynceStatusSourcesClockSourceNominationEntry 3 }
|
|
|
|
me1200SynceStatusSourcesClockSourceNominationSsm OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SSM"
|
|
::= { me1200SynceStatusSourcesClockSourceNominationEntry 4 }
|
|
|
|
me1200SynceStatusSourcesClockSourceNominationWtr OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"WTR"
|
|
::= { me1200SynceStatusSourcesClockSourceNominationEntry 5 }
|
|
|
|
me1200SynceStatusPorts OBJECT IDENTIFIER
|
|
::= { me1200SynceStatus 3 }
|
|
|
|
me1200SynceStatusPortsPortStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200SynceStatusPortsPortStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the port status."
|
|
::= { me1200SynceStatusPorts 1 }
|
|
|
|
me1200SynceStatusPortsPortStatusEntry OBJECT-TYPE
|
|
SYNTAX ME1200SynceStatusPortsPortStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The portId index must be a value must be a value from 0 up to the
|
|
number of ports minus one."
|
|
INDEX { me1200SynceStatusPortsPortStatusPortId }
|
|
::= { me1200SynceStatusPortsPortStatusTable 1 }
|
|
|
|
ME1200SynceStatusPortsPortStatusEntry ::= SEQUENCE {
|
|
me1200SynceStatusPortsPortStatusPortId ME1200InterfaceIndex,
|
|
me1200SynceStatusPortsPortStatusSsmRx ME1200synceQualityLevel,
|
|
me1200SynceStatusPortsPortStatusSsmTx ME1200synceQualityLevel,
|
|
me1200SynceStatusPortsPortStatusMaster TruthValue
|
|
}
|
|
|
|
me1200SynceStatusPortsPortStatusPortId OBJECT-TYPE
|
|
SYNTAX ME1200InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200SynceStatusPortsPortStatusEntry 1 }
|
|
|
|
me1200SynceStatusPortsPortStatusSsmRx OBJECT-TYPE
|
|
SYNTAX ME1200synceQualityLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Monitoring of the received SSM QL on this port."
|
|
::= { me1200SynceStatusPortsPortStatusEntry 2 }
|
|
|
|
me1200SynceStatusPortsPortStatusSsmTx OBJECT-TYPE
|
|
SYNTAX ME1200synceQualityLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Monitoring of the transmitted SSM QL on this port."
|
|
::= { me1200SynceStatusPortsPortStatusEntry 3 }
|
|
|
|
me1200SynceStatusPortsPortStatusMaster OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If PHY is in 1000BaseT Mode then this is monitoring the master/slave
|
|
mode."
|
|
::= { me1200SynceStatusPortsPortStatusEntry 4 }
|
|
|
|
me1200SynceStatusPtp OBJECT IDENTIFIER
|
|
::= { me1200SynceStatus 4 }
|
|
|
|
me1200SynceStatusPtpPortStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200SynceStatusPtpPortStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the PTP port status."
|
|
::= { me1200SynceStatusPtp 1 }
|
|
|
|
me1200SynceStatusPtpPortStatusEntry OBJECT-TYPE
|
|
SYNTAX ME1200SynceStatusPtpPortStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sourceId index must be a value must be a value from 0 up to the
|
|
number of PTP sources minus one."
|
|
INDEX { me1200SynceStatusPtpPortStatusSourceId }
|
|
::= { me1200SynceStatusPtpPortStatusTable 1 }
|
|
|
|
ME1200SynceStatusPtpPortStatusEntry ::= SEQUENCE {
|
|
me1200SynceStatusPtpPortStatusSourceId Integer32,
|
|
me1200SynceStatusPtpPortStatusSsmRx ME1200synceQualityLevel,
|
|
me1200SynceStatusPtpPortStatusPtsf ME1200syncePtsfState
|
|
}
|
|
|
|
me1200SynceStatusPtpPortStatusSourceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200SynceStatusPtpPortStatusEntry 1 }
|
|
|
|
me1200SynceStatusPtpPortStatusSsmRx OBJECT-TYPE
|
|
SYNTAX ME1200synceQualityLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Monitoring of the received SSM QL on this port."
|
|
::= { me1200SynceStatusPtpPortStatusEntry 2 }
|
|
|
|
me1200SynceStatusPtpPortStatusPtsf OBJECT-TYPE
|
|
SYNTAX ME1200syncePtsfState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PTSF status for PTP source."
|
|
::= { me1200SynceStatusPtpPortStatusEntry 3 }
|
|
|
|
me1200SynceControl OBJECT IDENTIFIER
|
|
::= { me1200SynceMibObjects 4 }
|
|
|
|
me1200SynceControlSources OBJECT IDENTIFIER
|
|
::= { me1200SynceControl 1 }
|
|
|
|
me1200SynceControlSourcesClockSourceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ME1200SynceControlSourcesClockSourceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the SyncE sources control structure."
|
|
::= { me1200SynceControlSources 1 }
|
|
|
|
me1200SynceControlSourcesClockSourceEntry OBJECT-TYPE
|
|
SYNTAX ME1200SynceControlSourcesClockSourceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sourceId index must be a value must be a value from 0 up to the
|
|
number of sources minus one."
|
|
INDEX { me1200SynceControlSourcesClockSourceSourceId }
|
|
::= { me1200SynceControlSourcesClockSourceTable 1 }
|
|
|
|
ME1200SynceControlSourcesClockSourceEntry ::= SEQUENCE {
|
|
me1200SynceControlSourcesClockSourceSourceId Integer32,
|
|
me1200SynceControlSourcesClockSourceClearWtr ME1200Unsigned8
|
|
}
|
|
|
|
me1200SynceControlSourcesClockSourceSourceId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200SynceControlSourcesClockSourceEntry 1 }
|
|
|
|
me1200SynceControlSourcesClockSourceClearWtr OBJECT-TYPE
|
|
SYNTAX ME1200Unsigned8
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"-"
|
|
::= { me1200SynceControlSourcesClockSourceEntry 2 }
|
|
|
|
me1200SynceNotificationPrefix OBJECT IDENTIFIER
|
|
::= { me1200SynceMibObjects 5 }
|
|
|
|
me1200SynceNotification OBJECT IDENTIFIER
|
|
::= { me1200SynceNotificationPrefix 0 }
|
|
|
|
me1200SynceNotificationClockSelectorStateChange NOTIFICATION-TYPE
|
|
OBJECTS { me1200SynceStatusGlobalClockSelectionModeClockInput,
|
|
me1200SynceStatusGlobalClockSelectionModeSelectorState }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification is sent when the clock selector state is changed."
|
|
::= { me1200SynceNotification 1 }
|
|
|
|
me1200SynceMibConformance OBJECT IDENTIFIER
|
|
::= { me1200SynceMib 2 }
|
|
|
|
me1200SynceMibCompliances OBJECT IDENTIFIER
|
|
::= { me1200SynceMibConformance 1 }
|
|
|
|
me1200SynceMibGroups OBJECT IDENTIFIER
|
|
::= { me1200SynceMibConformance 2 }
|
|
|
|
me1200SynceCapabilitiesGlobalInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceCapabilitiesGlobalSourceCount }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 1 }
|
|
|
|
me1200SynceConfigGlobalClockSelectionModeInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceConfigGlobalClockSelectionModeSelectionMode,
|
|
me1200SynceConfigGlobalClockSelectionModeSource,
|
|
me1200SynceConfigGlobalClockSelectionModeWtrTime,
|
|
me1200SynceConfigGlobalClockSelectionModeSsmHoldover,
|
|
me1200SynceConfigGlobalClockSelectionModeSsmFreerun,
|
|
me1200SynceConfigGlobalClockSelectionModeEecOption }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 2 }
|
|
|
|
me1200SynceConfigGlobalStationClocksInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceConfigGlobalStationClocksStationClkOut,
|
|
me1200SynceConfigGlobalStationClocksStationClkIn }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 3 }
|
|
|
|
me1200SynceConfigSourcesClockSourceNominationInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceConfigSourcesClockSourceNominationNominated,
|
|
me1200SynceConfigSourcesClockSourceNominationNetworkPort,
|
|
me1200SynceConfigSourcesClockSourceNominationClkInPort,
|
|
me1200SynceConfigSourcesClockSourceNominationPriority,
|
|
me1200SynceConfigSourcesClockSourceNominationAnegMode,
|
|
me1200SynceConfigSourcesClockSourceNominationSsmOverwrite,
|
|
me1200SynceConfigSourcesClockSourceNominationHoldoffTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 4 }
|
|
|
|
me1200SynceConfigPortsPortConfigInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceConfigPortsPortConfigSsmEnabled }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 5 }
|
|
|
|
me1200SynceStatusGlobalClockSelectionModeInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceStatusGlobalClockSelectionModeClockInput,
|
|
me1200SynceStatusGlobalClockSelectionModeSelectorState,
|
|
me1200SynceStatusGlobalClockSelectionModeLosx,
|
|
me1200SynceStatusGlobalClockSelectionModeLol,
|
|
me1200SynceStatusGlobalClockSelectionModeDhold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 6 }
|
|
|
|
me1200SynceStatusSourcesClockSourceNominationInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceStatusSourcesClockSourceNominationLocs,
|
|
me1200SynceStatusSourcesClockSourceNominationFos,
|
|
me1200SynceStatusSourcesClockSourceNominationSsm,
|
|
me1200SynceStatusSourcesClockSourceNominationWtr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 7 }
|
|
|
|
me1200SynceStatusPortsPortStatusInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceStatusPortsPortStatusSsmRx,
|
|
me1200SynceStatusPortsPortStatusSsmTx,
|
|
me1200SynceStatusPortsPortStatusMaster }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 8 }
|
|
|
|
me1200SynceStatusPtpPortStatusInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceStatusPtpPortStatusSsmRx,
|
|
me1200SynceStatusPtpPortStatusPtsf }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 9 }
|
|
|
|
me1200SynceControlSourcesClockSourceInfoGroup OBJECT-GROUP
|
|
OBJECTS { me1200SynceControlSourcesClockSourceClearWtr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 10 }
|
|
|
|
me1200SynceNotificationInfoGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { me1200SynceNotificationClockSelectorStateChange }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects suitable for bulk operations."
|
|
::= { me1200SynceMibGroups 11 }
|
|
|
|
me1200SynceMibCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the implementation."
|
|
|
|
MODULE -- this module
|
|
|
|
MANDATORY-GROUPS { me1200SynceCapabilitiesGlobalInfoGroup,
|
|
me1200SynceConfigGlobalClockSelectionModeInfoGroup,
|
|
me1200SynceConfigGlobalStationClocksInfoGroup,
|
|
me1200SynceConfigSourcesClockSourceNominationInfoGroup,
|
|
me1200SynceConfigPortsPortConfigInfoGroup,
|
|
me1200SynceStatusGlobalClockSelectionModeInfoGroup,
|
|
me1200SynceStatusSourcesClockSourceNominationInfoGroup,
|
|
me1200SynceStatusPortsPortStatusInfoGroup,
|
|
me1200SynceStatusPtpPortStatusInfoGroup,
|
|
me1200SynceControlSourcesClockSourceInfoGroup,
|
|
me1200SynceNotificationInfoGroup }
|
|
|
|
::= { me1200SynceMibCompliances 1 }
|
|
|
|
END
|