Observium_CE/mibs/cisco/CISCO-UNIFIED-COMPUTING-NOTIFS-MIB

98 lines
2.9 KiB
Plaintext

-- ********************************************************************
-- CISCO-UNIFIED-COMPUTING-NOTIFS-MIB.my
--
-- UCS Fault notifications (traps)
--
-- Copyright (c) 2005-2010 Cisco Systems, Inc. All rights reserved.
-- ********************************************************************
CISCO-UNIFIED-COMPUTING-NOTIFS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
ciscoMgmt
FROM CISCO-SMI
ciscoUnifiedComputingMIB,
ciscoUnifiedComputingMIBObjects
FROM CISCO-UNIFIED-COMPUTING-MIB
cucsFaultIndex,
cucsFaultDescription,
cucsFaultAffectedObjectId,
cucsFaultAffectedObjectDn,
cucsFaultCreationTime,
cucsFaultLastModificationTime,
cucsFaultCode,
cucsFaultType,
cucsFaultProbableCause,
cucsFaultSeverity,
cucsFaultOccur,
cucsFaultId
FROM CISCO-UNIFIED-COMPUTING-FAULT-MIB;
ciscoUnifiedComputingMIBNotifs MODULE-IDENTITY
LAST-UPDATED "201001290000Z"
ORGANIZATION "Cisco"
CONTACT-INFO
"Cisco Systems
Customer Service
Postal: 170 West Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: savbu-snmp-dev@cisco.com"
DESCRIPTION
"Fault traps (notifications) issued by the UCS system"
REVISION "201001290000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { ciscoUnifiedComputingMIB 0 }
cucsFaultActiveNotif NOTIFICATION-TYPE
OBJECTS {
cucsFaultIndex,
cucsFaultDescription,
cucsFaultAffectedObjectId,
cucsFaultAffectedObjectDn,
cucsFaultCreationTime,
cucsFaultLastModificationTime,
cucsFaultCode,
cucsFaultType,
cucsFaultProbableCause,
cucsFaultSeverity,
cucsFaultOccur,
cucsFaultId
}
STATUS current
DESCRIPTION
"This notification is generated by a UCS node whenever a fault
is active and the fault state changes."
::= { ciscoUnifiedComputingMIBNotifs 1 }
cucsFaultClearNotif NOTIFICATION-TYPE
OBJECTS {
cucsFaultIndex,
cucsFaultDescription,
cucsFaultAffectedObjectId,
cucsFaultAffectedObjectDn,
cucsFaultCreationTime,
cucsFaultLastModificationTime,
cucsFaultCode,
cucsFaultType,
cucsFaultProbableCause,
cucsFaultSeverity,
cucsFaultOccur,
cucsFaultId
}
STATUS current
DESCRIPTION
"This notification is generated by a UCS node whenever a fault
is cleared."
::= { ciscoUnifiedComputingMIBNotifs 2 }
END