276 lines
8.8 KiB
Plaintext
276 lines
8.8 KiB
Plaintext
-- *********************************************************************
|
|
-- CISCO-FIREPOWER-BMC-MIB.my
|
|
--
|
|
-- MIB representation of the Cisco Firepower
|
|
-- BMC management information model package
|
|
--
|
|
-- Created March 2020 by Charles Bullis
|
|
--
|
|
-- Copyright (c) 2005-2020 Cisco Systems, Inc. All rights reserved.
|
|
--
|
|
-- *********************************************************************
|
|
|
|
CISCO-FIREPOWER-BMC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Counter32,
|
|
Gauge32,
|
|
TimeTicks,
|
|
Counter64,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
RowPointer,
|
|
DateAndTime,
|
|
DisplayString,
|
|
MacAddress,
|
|
TimeInterval,
|
|
TimeStamp,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
InetAddressIPv4,
|
|
InetAddressIPv6
|
|
FROM INET-ADDRESS-MIB
|
|
ciscoMgmt
|
|
FROM CISCO-SMI
|
|
CiscoNetworkAddress,
|
|
Unsigned64,
|
|
CiscoInetAddressMask,
|
|
CiscoAlarmSeverity,
|
|
TimeIntervalSec
|
|
FROM CISCO-TC
|
|
ciscoFirepowerMIBObjects,
|
|
CfprManagedObjectId,
|
|
CfprManagedObjectDn
|
|
FROM CISCO-FIREPOWER-MIB
|
|
CfprBmcSELCntEqptClassId,
|
|
CfprBmcSELCntEqptInstIdPropId,
|
|
CfprBmcSELCntStatsClassId
|
|
FROM CISCO-FIREPOWER-TC-MIB;
|
|
|
|
cfprBmcObjects MODULE-IDENTITY
|
|
LAST-UPDATED "202003100000Z"
|
|
ORGANIZATION "Cisco Systems Inc."
|
|
CONTACT-INFO
|
|
"Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: firepower-mibs@cisco.com"
|
|
DESCRIPTION
|
|
"MIB representation of the Cisco Firepower
|
|
BMC management information model package"
|
|
::= { ciscoFirepowerMIBObjects 6 }
|
|
|
|
cfprBmcSELCounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CfprBmcSELCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter managed object table"
|
|
::= { cfprBmcObjects 1 }
|
|
|
|
cfprBmcSELCounterEntry OBJECT-TYPE
|
|
SYNTAX CfprBmcSELCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for the cfprBmcSELCounterTable table."
|
|
INDEX { cfprBmcSELCounterInstanceId }
|
|
::= { cfprBmcSELCounterTable 1 }
|
|
|
|
CfprBmcSELCounterEntry ::= SEQUENCE {
|
|
cfprBmcSELCounterInstanceId CfprManagedObjectId,
|
|
cfprBmcSELCounterDn CfprManagedObjectDn,
|
|
cfprBmcSELCounterRn SnmpAdminString,
|
|
cfprBmcSELCounterBitmask SnmpAdminString,
|
|
cfprBmcSELCounterCollInterval Gauge32,
|
|
cfprBmcSELCounterContClassId CfprBmcSELCntEqptClassId,
|
|
cfprBmcSELCounterContInstId SnmpAdminString,
|
|
cfprBmcSELCounterContInstIdPropId CfprBmcSELCntEqptInstIdPropId,
|
|
cfprBmcSELCounterEqptClassId CfprBmcSELCntEqptClassId,
|
|
cfprBmcSELCounterEqptInstId SnmpAdminString,
|
|
cfprBmcSELCounterEqptInstIdPropId CfprBmcSELCntEqptInstIdPropId,
|
|
cfprBmcSELCounterGlobalId SnmpAdminString,
|
|
cfprBmcSELCounterLocalId SnmpAdminString,
|
|
cfprBmcSELCounterPcGlobalId SnmpAdminString,
|
|
cfprBmcSELCounterPcLocalId SnmpAdminString,
|
|
cfprBmcSELCounterStatsClassId CfprBmcSELCntStatsClassId,
|
|
cfprBmcSELCounterStatsPropId INTEGER,
|
|
cfprBmcSELCounterThreshold Gauge32,
|
|
cfprBmcSELCounterValue SnmpAdminString
|
|
}
|
|
|
|
cfprBmcSELCounterInstanceId OBJECT-TYPE
|
|
SYNTAX CfprManagedObjectId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Instance identifier of the managed object."
|
|
::= { cfprBmcSELCounterEntry 1 }
|
|
|
|
cfprBmcSELCounterDn OBJECT-TYPE
|
|
SYNTAX CfprManagedObjectDn
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:dn managed object property"
|
|
::= { cfprBmcSELCounterEntry 2 }
|
|
|
|
cfprBmcSELCounterRn OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:rn managed object property"
|
|
::= { cfprBmcSELCounterEntry 3 }
|
|
|
|
cfprBmcSELCounterBitmask OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:bitmask managed object property"
|
|
::= { cfprBmcSELCounterEntry 4 }
|
|
|
|
cfprBmcSELCounterCollInterval OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:collInterval managed
|
|
object property"
|
|
::= { cfprBmcSELCounterEntry 5 }
|
|
|
|
cfprBmcSELCounterContClassId OBJECT-TYPE
|
|
SYNTAX CfprBmcSELCntEqptClassId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:contClassId managed
|
|
object property"
|
|
::= { cfprBmcSELCounterEntry 6 }
|
|
|
|
cfprBmcSELCounterContInstId OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:contInstId managed
|
|
object property"
|
|
::= { cfprBmcSELCounterEntry 7 }
|
|
|
|
cfprBmcSELCounterContInstIdPropId OBJECT-TYPE
|
|
SYNTAX CfprBmcSELCntEqptInstIdPropId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:contInstIdPropId
|
|
managed object property"
|
|
::= { cfprBmcSELCounterEntry 8 }
|
|
|
|
cfprBmcSELCounterEqptClassId OBJECT-TYPE
|
|
SYNTAX CfprBmcSELCntEqptClassId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:eqptClassId managed
|
|
object property"
|
|
::= { cfprBmcSELCounterEntry 9 }
|
|
|
|
cfprBmcSELCounterEqptInstId OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:eqptInstId managed
|
|
object property"
|
|
::= { cfprBmcSELCounterEntry 10 }
|
|
|
|
cfprBmcSELCounterEqptInstIdPropId OBJECT-TYPE
|
|
SYNTAX CfprBmcSELCntEqptInstIdPropId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:eqptInstIdPropId
|
|
managed object property"
|
|
::= { cfprBmcSELCounterEntry 11 }
|
|
|
|
cfprBmcSELCounterGlobalId OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:globalId managed object property"
|
|
::= { cfprBmcSELCounterEntry 12 }
|
|
|
|
cfprBmcSELCounterLocalId OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:localId managed object property"
|
|
::= { cfprBmcSELCounterEntry 13 }
|
|
|
|
cfprBmcSELCounterPcGlobalId OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:pcGlobalId managed
|
|
object property"
|
|
::= { cfprBmcSELCounterEntry 14 }
|
|
|
|
cfprBmcSELCounterPcLocalId OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:pcLocalId managed object property"
|
|
::= { cfprBmcSELCounterEntry 15 }
|
|
|
|
cfprBmcSELCounterStatsClassId OBJECT-TYPE
|
|
SYNTAX CfprBmcSELCntStatsClassId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:statsClassId managed
|
|
object property"
|
|
::= { cfprBmcSELCounterEntry 16 }
|
|
|
|
cfprBmcSELCounterStatsPropId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:statsPropId managed
|
|
object property"
|
|
::= { cfprBmcSELCounterEntry 17 }
|
|
|
|
cfprBmcSELCounterThreshold OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:threshold managed object property"
|
|
::= { cfprBmcSELCounterEntry 18 }
|
|
|
|
cfprBmcSELCounterValue OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cisco Firepower bmc:SELCounter:value managed object property"
|
|
::= { cfprBmcSELCounterEntry 19 }
|
|
|
|
END
|