-- CAREL-fcp.MIB
|
||
-- MIB generated by CAREL
|
||
-- Friday, 14 March 2003
|
||
--
|
||
|
||
CAREL-fcp-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
OBJECT-GROUP
|
||
FROM SNMPv2-CONF
|
||
sysContact, sysName, sysLocation
|
||
FROM SNMPv2-MIB
|
||
enterprises, MODULE-IDENTITY
|
||
FROM SNMPv2-SMI;
|
||
|
||
fcpMIB MODULE-IDENTITY
|
||
LAST-UPDATED "200303141725Z" -- March 14, 2003 at 17:25 GMT
|
||
ORGANIZATION "CAREL SpA"
|
||
CONTACT-INFO
|
||
"
|
||
Simone Ravazzolo
|
||
Carel SpA
|
||
Via dell'Industria, 11
|
||
35020 Brugine (PD) Italy
|
||
Tel: +39 049 9716611
|
||
E-mail: simone.ravazzolo@carel.com
|
||
"
|
||
DESCRIPTION
|
||
"This is the MIB module for the fcp device."
|
||
::= { instruments 1 }
|
||
|
||
|
||
--
|
||
-- Node definitions
|
||
--
|
||
|
||
-- 1.3.6.1.4.1.9839
|
||
carel OBJECT IDENTIFIER ::= { enterprises 9839 }
|
||
|
||
-- 1.3.6.1.4.1.9839.1
|
||
systm OBJECT IDENTIFIER ::= { carel 1 }
|
||
|
||
-- 1.3.6.1.4.1.9839.1.1
|
||
agentRelease OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Release of the Agent."
|
||
::= { systm 1 }
|
||
|
||
-- 1.3.6.1.4.1.9839.1.2
|
||
agentCode OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Code of the Agent. 1=WebGate"
|
||
::= { systm 2 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2
|
||
instruments OBJECT IDENTIFIER ::= { carel 2 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0
|
||
webGateInfo OBJECT IDENTIFIER ::= { instruments 0 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.1
|
||
agentParameters OBJECT IDENTIFIER ::= { webGateInfo 1 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.1.1
|
||
netSize OBJECT-TYPE
|
||
SYNTAX Integer32 (1..16)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Network size. It corresponds to the number of units connected to the WebGate. "
|
||
::= { agentParameters 1 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.1.2
|
||
baudRate OBJECT-TYPE
|
||
SYNTAX Integer32 (1200 | 2400 |4800 |9600 | 19200)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Baudrate of the Carel network. "
|
||
::= { agentParameters 2 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.2
|
||
unitTypeGroup OBJECT IDENTIFIER ::= { webGateInfo 2 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.2.1
|
||
unit1-Type OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of the unit having serial address 1. "
|
||
::= { unitTypeGroup 1 }
|
||
|
||
-- ... You will have how many unitX-Type objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.3
|
||
unitCodeGroup OBJECT IDENTIFIER ::= { webGateInfo 3 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.3.1
|
||
unit1-Code OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Code of the unit having serial address 1. "
|
||
::= { unitCodeGroup 1 }
|
||
|
||
-- ... You will have how many unitX-Code objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.4
|
||
unitSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 4 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.3.1
|
||
unit1-SoftwareRelease OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Software release of the unit having serial address 1. "
|
||
::= { unitSoftwareReleaseGroup 1 }
|
||
|
||
-- ... You will have how many unitX-SoftwareRelease objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.5
|
||
unitMinSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 5 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.5.1
|
||
unit1-MinSoftwareRelease OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Minimum software release of the unit having serial address 1. "
|
||
::= { unitMinSoftwareReleaseGroup 1 }
|
||
|
||
-- ... You will have how many unitX-MinSoftwareRelease objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.6
|
||
unitMaxSoftwareReleaseGroup OBJECT IDENTIFIER ::= { webGateInfo 6 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.6.1
|
||
unit1-MaxSoftwareRelease OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maximum software release of the unit having serial address 1. "
|
||
::= { unitMaxSoftwareReleaseGroup 1 }
|
||
|
||
-- ... You will have how many unitX-MaxSoftwareRelease objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.7
|
||
unitNoAnswerCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 7 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.7.1
|
||
unit1-NoAnswerCounter OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "No answer counter of the unit having serial address 1. "
|
||
::= { unitNoAnswerCounterGroup 1 }
|
||
|
||
-- ... You will have how many unitX-NoAnswerCounter objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.8
|
||
unitErrorChecksumCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 8 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.8.1
|
||
unit1-ErrorChecksumCounter OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Error checksum counter of the unit having serial address 1. "
|
||
::= { unitErrorChecksumCounterGroup 1 }
|
||
|
||
-- ... You will have how many unitX-ErrorChecksumCounter objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.9
|
||
unitTimeoutCounterGroup OBJECT IDENTIFIER ::= { webGateInfo 9 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.9.1
|
||
unit1-TimeoutCounter OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Timeout counter of the unit having serial address 1. "
|
||
::= { unitTimeoutCounterGroup 1 }
|
||
|
||
-- ... You will have how many unitX-TimeoutCounter objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.10
|
||
unitOnLineStatusGroup OBJECT IDENTIFIER ::= { webGateInfo 10 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.0.10.1
|
||
unit1-OnLineStatus OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "On line status of the unit having serial address 1. "
|
||
::= { unitOnLineStatusGroup 1 }
|
||
|
||
-- ... You will have how many unitX-OnLineStatus objects as the value of netSize is
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1
|
||
-- fcpMIB OBJECT IDENTIFIER ::= { instruments 1 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1
|
||
digitalObjects OBJECT IDENTIFIER ::= { fcpMIB 1 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.1
|
||
scheda_modem OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Presence of modem board"
|
||
::= { digitalObjects 1 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.2
|
||
present_expansion OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Presence of expansion board"
|
||
::= { digitalObjects 2 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.3
|
||
fan1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of fan 1"
|
||
::= { digitalObjects 3 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.4
|
||
fan2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of fan 2"
|
||
::= { digitalObjects 4 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.5
|
||
fan3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of fan 3"
|
||
::= { digitalObjects 5 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.6
|
||
fan4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of fan 4"
|
||
::= { digitalObjects 6 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.7
|
||
comp1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of compressor 1"
|
||
::= { digitalObjects 7 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.8
|
||
rich_parz11 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 1 compressor 1"
|
||
::= { digitalObjects 8 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.9
|
||
rich_parz21 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 2 compressor 1"
|
||
::= { digitalObjects 9 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.10
|
||
comp2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of compressor 2"
|
||
::= { digitalObjects 10 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.11
|
||
rich_parz12 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 1 compressor 2"
|
||
::= { digitalObjects 11 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.12
|
||
rich_parz22 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 2 compressor 2"
|
||
::= { digitalObjects 12 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.13
|
||
comp3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of compressor 3"
|
||
::= { digitalObjects 13 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.14
|
||
rich_parz13 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 1 compressor 3"
|
||
::= { digitalObjects 14 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.15
|
||
rich_parz23 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 2 compressor 3"
|
||
::= { digitalObjects 15 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.16
|
||
comp4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of compressor 4"
|
||
::= { digitalObjects 16 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.17
|
||
rich_parz14 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 1 compressor 4"
|
||
::= { digitalObjects 17 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.18
|
||
rich_parz24 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 2 compressor 4"
|
||
::= { digitalObjects 18 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.19
|
||
comp5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of compressor 5"
|
||
::= { digitalObjects 19 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.20
|
||
rich_parz15 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 1 compressor 5"
|
||
::= { digitalObjects 20 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.21
|
||
rich_parz25 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 2 compressor 5"
|
||
::= { digitalObjects 21 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.22
|
||
comp6 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of compressor 6"
|
||
::= { digitalObjects 22 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.23
|
||
rich_parz16 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 1 compressor 6"
|
||
::= { digitalObjects 23 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.24
|
||
rich_parz26 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of capacity-control 2 compressor 6"
|
||
::= { digitalObjects 24 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.25
|
||
din1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 1"
|
||
::= { digitalObjects 25 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.26
|
||
din2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 2"
|
||
::= { digitalObjects 26 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.27
|
||
din3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 3"
|
||
::= { digitalObjects 27 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.28
|
||
din4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 4"
|
||
::= { digitalObjects 28 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.29
|
||
din5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 5"
|
||
::= { digitalObjects 29 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.30
|
||
din6 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 6"
|
||
::= { digitalObjects 30 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.31
|
||
din7 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 7"
|
||
::= { digitalObjects 31 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.32
|
||
din8 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 8"
|
||
::= { digitalObjects 32 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.33
|
||
din9 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 9"
|
||
::= { digitalObjects 33 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.34
|
||
din10 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 10"
|
||
::= { digitalObjects 34 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.35
|
||
din11 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 11"
|
||
::= { digitalObjects 35 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.36
|
||
din12 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 12"
|
||
::= { digitalObjects 36 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.37
|
||
din13 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 13"
|
||
::= { digitalObjects 37 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.38
|
||
din14 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 14"
|
||
::= { digitalObjects 38 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.39
|
||
din15 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 15"
|
||
::= { digitalObjects 39 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.40
|
||
din16 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 16"
|
||
::= { digitalObjects 40 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.41
|
||
din17 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 17"
|
||
::= { digitalObjects 41 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.42
|
||
din18 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input 18"
|
||
::= { digitalObjects 42 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.43
|
||
all_pres_lpres OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low pressure switch alarm"
|
||
::= { digitalObjects 43 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.44
|
||
all_pres_hpres OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High pressure switch alarm"
|
||
::= { digitalObjects 44 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.45
|
||
din101 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input expansion no.1"
|
||
::= { digitalObjects 45 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.46
|
||
din102 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input expansion no.2"
|
||
::= { digitalObjects 46 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.47
|
||
din103 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input expansion no.3"
|
||
::= { digitalObjects 47 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.48
|
||
din104 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input expansion no.4"
|
||
::= { digitalObjects 48 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.49
|
||
din105 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input expansion no.5"
|
||
::= { digitalObjects 49 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.50
|
||
din106 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input expansion no.6"
|
||
::= { digitalObjects 50 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.51
|
||
din107 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input expansion no.7"
|
||
::= { digitalObjects 51 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.52
|
||
din108 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital input expansion no.8"
|
||
::= { digitalObjects 52 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.53
|
||
mall_term_klix1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm compressor 1"
|
||
::= { digitalObjects 53 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.54
|
||
mall_term_klix2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm compressor 2"
|
||
::= { digitalObjects 54 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.55
|
||
mall_term_klix3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm compressor 3"
|
||
::= { digitalObjects 55 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.56
|
||
mall_term_klix4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm compressor 4"
|
||
::= { digitalObjects 56 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.57
|
||
mall_term_klix5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm compressor 5"
|
||
::= { digitalObjects 57 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.58
|
||
mall_term_klix6 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm compressor 6"
|
||
::= { digitalObjects 58 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.59
|
||
mall_pres_h1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High/low pressure switch alarm compressor 1"
|
||
::= { digitalObjects 59 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.60
|
||
mall_pres_h2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High/low pressure switch alarm compressor 2"
|
||
::= { digitalObjects 60 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.61
|
||
mall_pres_h3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High/low pressure switch alarm compressor 3"
|
||
::= { digitalObjects 61 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.62
|
||
mall_pres_h4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High/low pressure switch alarm compressor 4"
|
||
::= { digitalObjects 62 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.63
|
||
mall_pres_h5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High/low pressure switch alarm compressor 5"
|
||
::= { digitalObjects 63 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.64
|
||
mall_pres_h6 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High/low pressure switch alarm compressor 6"
|
||
::= { digitalObjects 64 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.65
|
||
mall_dif_olio1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Oil differential alarm compressor 1"
|
||
::= { digitalObjects 65 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.66
|
||
mall_dif_olio2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Oil differential alarm compressor 2"
|
||
::= { digitalObjects 66 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.67
|
||
mall_dif_olio3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Oil differential alarm compressor 3"
|
||
::= { digitalObjects 67 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.68
|
||
mall_dif_olio4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Oil differential alarm compressor 4"
|
||
::= { digitalObjects 68 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.69
|
||
mall_dif_olio5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Oil differential alarm compressor 5"
|
||
::= { digitalObjects 69 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.70
|
||
mall_dif_olio6 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Oil differential alarm compressor 6"
|
||
::= { digitalObjects 70 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.71
|
||
mall_ore_comp1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maintenance hours threshold exceeded alarm,comp1"
|
||
::= { digitalObjects 71 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.72
|
||
mall_ore_comp2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maintenance hours threshold exceeded alarm,comp2"
|
||
::= { digitalObjects 72 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.73
|
||
mall_ore_comp3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maintenance hours threshold exceeded alarm,comp3"
|
||
::= { digitalObjects 73 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.74
|
||
mall_ore_comp4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maintenance hours threshold exceeded alarm,comp4"
|
||
::= { digitalObjects 74 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.75
|
||
mall_ore_comp5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maintenance hours threshold exceeded alarm,comp5"
|
||
::= { digitalObjects 75 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.76
|
||
mall_ore_comp6 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Maintenance hours threshold exceeded alarm,comp6"
|
||
::= { digitalObjects 76 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.77
|
||
mall_term_vent1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm fan 1"
|
||
::= { digitalObjects 77 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.78
|
||
mall_term_vent2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm fan 2"
|
||
::= { digitalObjects 78 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.79
|
||
mall_term_vent3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm fan 3"
|
||
::= { digitalObjects 79 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.80
|
||
mall_term_vent4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm fan 4"
|
||
::= { digitalObjects 80 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.81
|
||
mal_liquid_level OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Liquid level alarm"
|
||
::= { digitalObjects 81 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.82
|
||
mall_pres_lpres OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "General low pressure switch alarm"
|
||
::= { digitalObjects 82 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.83
|
||
mall_pres_hpres OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "General high pressure switch alarm"
|
||
::= { digitalObjects 83 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.84
|
||
mal_low2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low pressure outlet probe alarm"
|
||
::= { digitalObjects 84 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.85
|
||
mall_alta_mand OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High pressure outlet probe alarm"
|
||
::= { digitalObjects 85 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.86
|
||
mal_low_press OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low pressure inlet probe alarm"
|
||
::= { digitalObjects 86 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.87
|
||
mal_high_press OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High pressure inlet probe alarm"
|
||
::= { digitalObjects 87 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.88
|
||
mal_n_input OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Exceeded number of inputs available alarm"
|
||
::= { digitalObjects 88 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.89
|
||
mal_n_devices OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Exceeded number of devices available alarm"
|
||
::= { digitalObjects 89 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.90
|
||
mall_ora OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Clock fault or flat battery alarm"
|
||
::= { digitalObjects 90 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.91
|
||
mal_broke_pr1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Inlet probe faulty or disconnected alarm"
|
||
::= { digitalObjects 91 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.92
|
||
mal_broke_pr2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Outlet probe faulty or disconnected alarm"
|
||
::= { digitalObjects 92 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.93
|
||
glb_al OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "General alarm signal"
|
||
::= { digitalObjects 93 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.101
|
||
syson OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Unit status"
|
||
::= { digitalObjects 101 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.112
|
||
en_off_supervisor OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Enable ON/OFF from supervisor"
|
||
DEFVAL { 0 }
|
||
::= { digitalObjects 112 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.114
|
||
fan5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of fan 5"
|
||
::= { digitalObjects 114 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.115
|
||
mall_term_vent5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Thermal overload alarm fan 5"
|
||
::= { digitalObjects 115 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.118
|
||
en_on_balck_out OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Enable delay at restart after Black-Out"
|
||
::= { digitalObjects 118 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.119
|
||
dout1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 1"
|
||
::= { digitalObjects 119 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.120
|
||
dout2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 2"
|
||
::= { digitalObjects 120 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.121
|
||
dout3 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 3"
|
||
::= { digitalObjects 121 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.122
|
||
dout4 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 4"
|
||
::= { digitalObjects 122 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.123
|
||
dout5 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 5"
|
||
::= { digitalObjects 123 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.124
|
||
dout6 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 6"
|
||
::= { digitalObjects 124 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.125
|
||
dout7 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 7"
|
||
::= { digitalObjects 125 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.126
|
||
dout8 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 8"
|
||
::= { digitalObjects 126 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.127
|
||
dout9 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 9"
|
||
::= { digitalObjects 127 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.128
|
||
dout10 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 10"
|
||
::= { digitalObjects 128 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.129
|
||
dout11 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 11"
|
||
::= { digitalObjects 129 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.130
|
||
dout12 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 12"
|
||
::= { digitalObjects 130 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.131
|
||
dout13 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 13"
|
||
::= { digitalObjects 131 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.132
|
||
dout14 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 14"
|
||
::= { digitalObjects 132 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.133
|
||
dout15 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 15"
|
||
::= { digitalObjects 133 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.134
|
||
dout16 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 16"
|
||
::= { digitalObjects 134 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.135
|
||
dout17 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 17"
|
||
::= { digitalObjects 135 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.1.136
|
||
dout18 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of digital output 18"
|
||
::= { digitalObjects 136 }
|
||
|
||
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2
|
||
analogObjects OBJECT IDENTIFIER ::= { fcpMIB 2 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.1
|
||
asp_conv OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Suction pressure"
|
||
::= { analogObjects 1 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.2
|
||
press_mand_conv OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Discharge pressure"
|
||
::= { analogObjects 2 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.3
|
||
out_inv_fan OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Value of analogue output 1"
|
||
::= { analogObjects 3 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.4
|
||
inverter_comp1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Value of analogue output 2"
|
||
::= { analogObjects 4 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.5
|
||
set_comp OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Compressor set-point"
|
||
DEFVAL { 10 }
|
||
::= { analogObjects 5 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.6
|
||
diff_comp OBJECT-TYPE
|
||
SYNTAX Integer32 (0..20)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Compressor differential"
|
||
DEFVAL { 50 }
|
||
::= { analogObjects 6 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.7
|
||
set_fan OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Fan set-point"
|
||
DEFVAL { 155 }
|
||
::= { analogObjects 7 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.8
|
||
diff_fan OBJECT-TYPE
|
||
SYNTAX Integer32 (0..200)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Fan differential"
|
||
DEFVAL { 20 }
|
||
::= { analogObjects 8 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.9
|
||
voltage_in OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Power supply voltage to the pCO<43> board"
|
||
::= { analogObjects 9 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.10
|
||
max_set_co OBJECT-TYPE
|
||
SYNTAX Integer32 (-99..999)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Maximum compressor Set Point"
|
||
DEFVAL { 1 }
|
||
::= { analogObjects 10 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.11
|
||
min_set_co OBJECT-TYPE
|
||
SYNTAX Integer32 (-99..999)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Minimum compressor Set Point"
|
||
DEFVAL { 25 }
|
||
::= { analogObjects 11 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.12
|
||
max_set_fa OBJECT-TYPE
|
||
SYNTAX Integer32 (-99..999)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Maximum Fan Set Point"
|
||
DEFVAL { 250 }
|
||
::= { analogObjects 12 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.13
|
||
min_set_fa OBJECT-TYPE
|
||
SYNTAX Integer32 (-99..999)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Minimum Fan Set Point"
|
||
DEFVAL { 10 }
|
||
::= { analogObjects 13 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.14
|
||
thresh_high1 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..100)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Suction high pressure alarm set"
|
||
DEFVAL { 50 }
|
||
::= { analogObjects 14 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.15
|
||
diff_high1 OBJECT-TYPE
|
||
SYNTAX Integer32 (1..20)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "High inlet alarm differential"
|
||
DEFVAL { 5 }
|
||
::= { analogObjects 15 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.16
|
||
thresh_low1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-100..50)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Suction low pressure alarm set"
|
||
DEFVAL { 10 }
|
||
::= { analogObjects 16 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.17
|
||
diff_low1 OBJECT-TYPE
|
||
SYNTAX Integer32 (1..10)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Low inlet alarm differential"
|
||
DEFVAL { 5 }
|
||
::= { analogObjects 17 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.18
|
||
thresh_high2 OBJECT-TYPE
|
||
SYNTAX Integer32 (150..300)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Discharge high pressure alarm set"
|
||
DEFVAL { 185 }
|
||
::= { analogObjects 18 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.19
|
||
diff_high2 OBJECT-TYPE
|
||
SYNTAX Integer32 (2..40)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "High outlet alarm differential"
|
||
DEFVAL { 10 }
|
||
::= { analogObjects 19 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.20
|
||
thresh_low2 OBJECT-TYPE
|
||
SYNTAX Integer32 (-100..300)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Discharge low pressure alarm set"
|
||
DEFVAL { 100 }
|
||
::= { analogObjects 20 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.21
|
||
diff_low2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..3600)
|
||
UNITS "sec x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Low outlet alarm differential"
|
||
DEFVAL { 1200 }
|
||
::= { analogObjects 21 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.27
|
||
set_vent_inv OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "fan inverter Set Point"
|
||
DEFVAL { 155 }
|
||
::= { analogObjects 27 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.28
|
||
diff_vent_inv OBJECT-TYPE
|
||
SYNTAX Integer32 (0..200)
|
||
UNITS "bar x10"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Fan inverter differential"
|
||
DEFVAL { 15 }
|
||
::= { analogObjects 28 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.32
|
||
seinverter OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Set point inverter compressor (proportional band)"
|
||
::= { analogObjects 32 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.2.33
|
||
diff_inv OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Differential inverter compressor (proportional band)"
|
||
::= { analogObjects 33 }
|
||
|
||
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3
|
||
integerObjects OBJECT IDENTIFIER ::= { fcpMIB 3 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.11
|
||
lhour OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Hour setting value"
|
||
::= { integerObjects 11 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.12
|
||
lminute OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Minute setting value"
|
||
::= { integerObjects 12 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.13
|
||
lday OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Day setting value"
|
||
::= { integerObjects 13 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.14
|
||
lmonth OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Month setting value"
|
||
::= { integerObjects 14 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.15
|
||
lyear OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Year setting value"
|
||
::= { integerObjects 15 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.16
|
||
hour OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Current hour"
|
||
::= { integerObjects 16 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.17
|
||
minute OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Current minute"
|
||
::= { integerObjects 17 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.18
|
||
month OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Current month"
|
||
::= { integerObjects 18 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.19
|
||
pyear OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Curre3nt year"
|
||
::= { integerObjects 19 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.21
|
||
oil_diff OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Alarm oil differential delay on running"
|
||
::= { integerObjects 21 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.26
|
||
out_inv_fani OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of analogue output 1"
|
||
::= { integerObjects 26 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.27
|
||
inverter_compi1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Status of analogue output 2"
|
||
::= { integerObjects 27 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.28
|
||
board_type OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of board connected"
|
||
::= { integerObjects 28 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.29
|
||
unit_status OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "On, OFF from alarm, OFF from supervisor"
|
||
::= { integerObjects 29 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.30
|
||
type_b1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of probe b1 connected"
|
||
::= { integerObjects 30 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.31
|
||
type_b2 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "type of probe b2 connected"
|
||
::= { integerObjects 31 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.32
|
||
bios_release OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Version of bios used"
|
||
::= { integerObjects 32 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.33
|
||
bios_date OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Date of bios used"
|
||
::= { integerObjects 33 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.34
|
||
boot_release OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Version of boot used"
|
||
::= { integerObjects 34 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.35
|
||
boot_date OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Date of boot used"
|
||
::= { integerObjects 35 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.37
|
||
time_switch_on1 OBJECT-TYPE
|
||
SYNTAX Integer32 (10..360)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay in calling compressor starts (dead zone)"
|
||
DEFVAL { 20 }
|
||
::= { integerObjects 37 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.38
|
||
time_switchoff1 OBJECT-TYPE
|
||
SYNTAX Integer32 (10..360)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay in calling compressor stops (dead zone)"
|
||
DEFVAL { 10 }
|
||
::= { integerObjects 38 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.39
|
||
time_min_on OBJECT-TYPE
|
||
SYNTAX Integer32 (10..360)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Minimum compressor ON time"
|
||
DEFVAL { 60 }
|
||
::= { integerObjects 39 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.40
|
||
time_min_off OBJECT-TYPE
|
||
SYNTAX Integer32 (10..360)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Minimum compressor OFF time"
|
||
DEFVAL { 120 }
|
||
::= { integerObjects 40 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.41
|
||
time_betw_comp OBJECT-TYPE
|
||
SYNTAX Integer32 (0..9999)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay time between starts of different compressors"
|
||
DEFVAL { 20 }
|
||
::= { integerObjects 41 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.42
|
||
time_same_comp OBJECT-TYPE
|
||
SYNTAX Integer32 (240..600)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Time of delay between started of same compressor"
|
||
DEFVAL { 360 }
|
||
::= { integerObjects 42 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.43
|
||
unload_delay OBJECT-TYPE
|
||
SYNTAX Integer32 (0..999)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay in capacity-control steps"
|
||
DEFVAL { 20 }
|
||
::= { integerObjects 43 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.44
|
||
time_switch_on2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..999)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay in calling fan starts (dead zone)"
|
||
DEFVAL { 2 }
|
||
::= { integerObjects 44 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.45
|
||
time_switchoff2 OBJECT-TYPE
|
||
SYNTAX Integer32 (0..999)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay in calling fan stops (dead zone)"
|
||
DEFVAL { 2 }
|
||
::= { integerObjects 45 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.46
|
||
time_betw_fan OBJECT-TYPE
|
||
SYNTAX Integer32 (0..999)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay time between starts of different fans"
|
||
DEFVAL { 5 }
|
||
::= { integerObjects 46 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.47
|
||
rit_dif_olio OBJECT-TYPE
|
||
SYNTAX Integer32 (0..360)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay in oil differential alarm at start"
|
||
DEFVAL { 90 }
|
||
::= { integerObjects 47 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.48
|
||
rit_all_liq OBJECT-TYPE
|
||
SYNTAX Integer32 (0..360)
|
||
UNITS "sec"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Delay in liquid level alarm"
|
||
DEFVAL { 10 }
|
||
::= { integerObjects 48 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.53
|
||
sg_ore_comp OBJECT-TYPE
|
||
SYNTAX Integer32 (0..99999)
|
||
UNITS "Hours"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Compressor operating hour threshold (by 1000)"
|
||
DEFVAL { 1000 }
|
||
::= { integerObjects 53 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.54
|
||
hour_comp1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours compressor 1"
|
||
::= { integerObjects 54 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.55
|
||
hour_l_comp1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours compressor 1"
|
||
::= { integerObjects 55 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.56
|
||
hour_comp2 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours compressor 2"
|
||
::= { integerObjects 56 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.57
|
||
hour_l_comp2 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours compressor 2"
|
||
::= { integerObjects 57 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.58
|
||
hour_comp3 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours compressor 3"
|
||
::= { integerObjects 58 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.59
|
||
hour_l_comp3 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours compressor 3"
|
||
::= { integerObjects 59 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.60
|
||
hour_comp4 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours compressor 4"
|
||
::= { integerObjects 60 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.61
|
||
hour_l_comp4 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours compressor 4"
|
||
::= { integerObjects 61 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.62
|
||
hour_comp5 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours compressor 5"
|
||
::= { integerObjects 62 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.63
|
||
hour_l_comp5 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours compressor 5"
|
||
::= { integerObjects 63 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.64
|
||
hour_comp6 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours compressor 6"
|
||
::= { integerObjects 64 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.65
|
||
hour_l_comp6 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours compressor 6"
|
||
::= { integerObjects 65 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.66
|
||
h_hour_fan1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours fan 1"
|
||
::= { integerObjects 66 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.67
|
||
l_hour_fan1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours fan 1"
|
||
::= { integerObjects 67 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.68
|
||
h_hour_fan2 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours fan 2"
|
||
::= { integerObjects 68 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.69
|
||
l_hour_fan2 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours fan 2"
|
||
::= { integerObjects 69 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.70
|
||
h_hour_fan3 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours fan 3"
|
||
::= { integerObjects 70 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.71
|
||
l_hour_fan3 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours fan 3"
|
||
::= { integerObjects 71 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.72
|
||
h_hour_fan4 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours fan 4"
|
||
::= { integerObjects 72 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.73
|
||
l_hour_fan4 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours fan 4"
|
||
::= { integerObjects 73 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.74
|
||
sg_ore_fan OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Fan maintenance threshold alarm (by 1000)"
|
||
::= { integerObjects 74 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.75
|
||
version OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Version application"
|
||
::= { integerObjects 75 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.76
|
||
h_hour_fan5 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "High part, operating hours fan 5"
|
||
::= { integerObjects 76 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.77
|
||
l_hour_fan5 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Low part, operating hours fan 5"
|
||
::= { integerObjects 77 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.78
|
||
time_on_black_out OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Minimum off time after restart from black-out"
|
||
::= { integerObjects 78 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.79
|
||
config_in1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 1"
|
||
::= { integerObjects 79 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.80
|
||
config_in2 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 2"
|
||
::= { integerObjects 80 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.81
|
||
config_in3 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 3"
|
||
::= { integerObjects 81 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.82
|
||
config_in4 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 4"
|
||
::= { integerObjects 82 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.83
|
||
config_in5 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 5"
|
||
::= { integerObjects 83 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.84
|
||
config_in6 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 6"
|
||
::= { integerObjects 84 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.85
|
||
config_in7 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 7"
|
||
::= { integerObjects 85 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.86
|
||
config_in8 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 8"
|
||
::= { integerObjects 86 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.87
|
||
config_in9 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 9"
|
||
::= { integerObjects 87 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.88
|
||
config_in10 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 10"
|
||
::= { integerObjects 88 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.89
|
||
config_in11 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 11"
|
||
::= { integerObjects 89 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.90
|
||
config_in12 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 12"
|
||
::= { integerObjects 90 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.91
|
||
config_in13 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 13"
|
||
::= { integerObjects 91 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.92
|
||
config_in14 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 14"
|
||
::= { integerObjects 92 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.93
|
||
config_in15 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 15"
|
||
::= { integerObjects 93 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.94
|
||
config_in16 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 16"
|
||
::= { integerObjects 94 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.95
|
||
config_in17 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 17"
|
||
::= { integerObjects 95 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.96
|
||
config_in18 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to input 18"
|
||
::= { integerObjects 96 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.97
|
||
config_out1 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 1"
|
||
::= { integerObjects 97 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.98
|
||
config_out2 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 2"
|
||
::= { integerObjects 98 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.99
|
||
config_out3 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 3"
|
||
::= { integerObjects 99 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.100
|
||
config_out4 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 4"
|
||
::= { integerObjects 100 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.101
|
||
config_out5 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 5"
|
||
::= { integerObjects 101 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.102
|
||
config_out6 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 6"
|
||
::= { integerObjects 102 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.103
|
||
config_out7 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 7"
|
||
::= { integerObjects 103 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.104
|
||
config_out8 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 8"
|
||
::= { integerObjects 104 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.105
|
||
config_out9 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 9"
|
||
::= { integerObjects 105 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.106
|
||
config_out10 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 10"
|
||
::= { integerObjects 106 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.107
|
||
config_out11 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 11"
|
||
::= { integerObjects 107 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.108
|
||
config_out12 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 12"
|
||
::= { integerObjects 108 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.109
|
||
config_out13 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 13"
|
||
::= { integerObjects 109 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.110
|
||
config_out14 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 14"
|
||
::= { integerObjects 110 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.111
|
||
config_out15 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 15"
|
||
::= { integerObjects 111 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.112
|
||
config_out16 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 16"
|
||
::= { integerObjects 112 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.113
|
||
config_out17 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 17"
|
||
::= { integerObjects 113 }
|
||
|
||
-- 1.3.6.1.4.1.9839.2.1.3.114
|
||
config_out18 OBJECT-TYPE
|
||
SYNTAX Integer32 (-32767..32767)
|
||
UNITS "N/A"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION "Type of device connected to output 18"
|
||
::= { integerObjects 114 }
|
||
|
||
|
||
|
||
END
|
||
|
||
--
|
||
-- CAREL-fcp.MIB
|
||
--
|